2280 FARADAY AV; ; AS110157; Permit
Sprinkler Permit Job Address: 2280 FARADAY AV Permit Type: SPRINK Parcel No: 2120614500 Lot #: 0 Permit No: AS110157 Status: FINAL Applied 10/10/2011 Approved: 12/1/2011 Reference No.: Issued: 12/1/2011 PC #: Inspector: Project Title: ISIS PHARMA - FLAMM LIQ STORAG Applicant: AAA FIRE SPRINKLERS 20942 JAPATUL RD. ALPINE, CA Owner: FARADAY PARTNERS L L C C/O DEl LLC 1800 THIBODO RD #320 VISTA CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 802 0 802 0 ISIS SYSTEM UPGRADE NEW SYSTEM FOR FLAMMABLE LIQUIDS STORAGE ROOM MATERIAL DATA SUBMITTAL AAA FIRE SPRINKLERS 20942 JAPATUL RD. ALPINE, CA 91901 (619) 445-9898 FAX (619) 445-4052 C16 908752 APPJ1OIED AS SUBMITTED _47 ij CA[AD FIRE D. EPARE1 F.~E.VL.'.Ev - Fire Protection by Computer Design AM FIRE SPRINKLERS 20942 JAPATUL RD. ALPINE, CA 91901 619-445-9898 Job Name : ISIS SYSTEM UPGRADE Building : FP-2 Location : 2280 FARADY AVENUE System AREA #1 Contract Data File ISIS SYSTEM UPGRADE H-3 H-4.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 AM FIRE SPRINKLERS Page 1 ISIS SYSTEM UPGRADE Date 7-1-11 HYDRAULIC CALCULATIONS for Project name: ISIS SYSTEM UPGRADE Location: 2280 FARADY AVENUE Drawing no: FP-2 Date: 9-1-11 Design Remote area number: AREA #1 Remote area location: FLAMMABLE LIQUIDS STORAGE ROOM Occupancy classification: H-3, H-4 EXTRA HAZARD Density: .6 - Gpm/SqFt Area of application: ENTIRE ROOM - SqFt Coverage per sprinkler: 96 - SqFt Type of sprinklers calculated: 16.8K UPRIGHT 286 DEG. No. of sprinklers calculated: 29 In-rack demand: N/A- GPM Hose streams: 700 - GPM Total water required (including hose streams): 2452.775 -GPM @ 70.605 - Psi Type of system: WET TREE Volume of dry orpreaction system: N/A - Gal Water supply information Date: Location: SITE Source: SAN DIEGO DEVELOPMENT SERVICES Name of contractor: AM FIRE SPRINKLERS Address: 20942 JAPATUL RD. / / ALPINE, CA 91901 Phone number: 619-445-9898 Name of designer: C. HOLLANDS Authority ha ving jurisdiction: CARLSBAD FIRE DEPARTMENT Notes: (Include peaking information or gridded systems here.) A 10% REDUCTION HAS BEEN TAKEN PRIOR TO DATA ENTRY. DESIGN DENSITY AND HOSE ALLOWANCE DERIVED FROM TECHNICAL REPORT. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) AAA FIRE SPRINKLERS Page 2 ISIS SYSTEM UPGRADE Date 7-1-11 City Water Supply: Demand: Cl - Static Pressure : 90.9 Dl - Elevation : 9.095 C2 - Residual Pressure: 88.2 02 - System Flow : 1752.77 C2 - Residual Flow : 1471.7 02 - System Pressure : 70.605 Hose(Adj City) Hose ( Demand) : 700 D3 - System Demand : 2452.77 Safety Margin : 13.349 150 140 130 p120 R11° E10° ____ ______ ________ C2 - S90 ___ ____ _____ s 80 U 70 93 R 60 • E 50 D2 40 __ 30 20 __ 10 300 600 900 1200 1500 1800 2100 2400 2700 FLOW (N"1.85) - Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram AAA FIRE SPRINKLERS ISIS SYSTEM UPGRADE 57.6 173.8 SI - S2 -. S3 S4 - lOT 115.4 233.6 57.8 174.3 55 - S8 - S7 -. S8 - lOT 115.7 234.2 57.7 174.1 S9 - S14- S114- S124- lIT 115.6 234 57.9 174.6 S134- SI4 S15+.. S164- lIT 115.9 234.6 58.1 175.2 SI7 S18 S194- S20 I2T 116.3 235.4 58.2 175.7 S214- S224- S234- S244- I2T 116.6 236.1 66.5 200.7 S254- S284- S27 S284- I3T 133.2 269.6 75.3 S29 I3T 467.8 IOT4- 10 1 I 467.8 46.6 lIT4- 11 t I 936.4 471.5 I2T4-. 12 T I 1407.9 341.9 I3T4- 13 Page 3 Date 7-1-11 467.8 1407.9 1752.8 1752.8 1752.8 10 . II . 12 _ 13 -. TR 4-BR - BFI4- BF24- UG - UGI4- SRC 936.4 1752.8 1752.8 1752.8 1752.8 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary ,AAA FIRE SPRINKLERS Page 4 ISIS SYSTEM UPGRADE Date 7-1-11 Fitting Legend Abbrev. Name 1/2 % 1 1% 1% 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 B Generic Butterfly Valve 0 0 0 0 0 0 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E 90'StandardElbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 K Generic Detector Check Valve 0 0 0 0 0 0 0 14 0 14 0 36 55 45 0 0 0 0 0 0 T 90FlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD MA FIRE SPRINKLERS Page 5 ISIS SYSTEM UPGRADE Date 7-1-11 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. Si 17.0 16.8 11.76 na 57.6 0.6 96 7.0 S2 17.0 16.8 11.83 na 57.78 0.6 96 7.0 S3 17.0 16.8 12.09 na 58.42 0.6 96 7.0 S4 17.0 16.8 12.66 na 59.77 0.6 96 7.0 S5 17.0 16.8 11.82 na 57.75 0.6 96 7.0 S6 17.0 16.8 11.89 na 57.93 0.6 96 . 7.0 S7 17.0 16.8 12.16 na 58.58 0.6 96 7.0 SB 17.0 16.8 12.73 na 59.93 0.6 96 7.0 S9 17.0 16.8 11.8 na 57.7 0.6 96 7.0 S1O 17.0 16.8 11.87 na 57.88 0.6 96 7.0 Sil 17.0 16.8 12.14 na 58.53 0.6 96 7.0 S12 17.0 16.8 12.7 na 59.88 0.6 96 7.0 S13 17.0 16.8 11.86 na 57.85 0.6 96 7.0 S14 17.0 16.8 11.93 na 58.03 0.6 96 7.0 S15 17.0 16.8 12.2 na 58.68 0.6 96 7.0 S16 17.0 16.8 12.77 na 60.04 0.6 96 7.0 S17 17.0 16.8 11.94 na 58.06 0.6 96 7.0 S18 17.0 16.8 12.02 na 58.24 0.6 96 7.0 S19 17.0 16.8 12.29 na 58.89 0.6 96 7.0 S20 17.0 16.8 12.86 na 60.25 0.6 96 7.0 S21 17.0 16.8 12.01 na 58.22 0.6 96 7.0 S22 17.0 16.8 12.08 na 58.4 0.6 96 7.0 S23 17.0 16.8 12.35 na 59.05 0.6 96 7.0 S24 17.0 16.8 12.93 na 60.41 0.6 96 7.0 S25 17.0 16.8 15.67 na 66.51 0.6 96 7.0 S26 17.0 16.8 15.77 na 66.71 0.6 96 7.0 S27 17.0 16.8 16.12 na 67.44 0.6 96 7.0 S28 17.0 16.8 16.85 na 68.97 0.6 96 7.0 S29 17.0 16.8 20.07 na 75.26 0.6 96 7.0 lOT 17.0 15.47 na liT 17.0 15.52 na 12T 17.0 15.71 na 13T 17.0 20.41 na 10 15.0 25.46 na ii 15.0 25.54 na 12 15.0 25.84 na 13 15.0 26.47 na TR 15.0 33.62 na BR 2.0 44.25 na BF1 2.0 45.99 na BF2 4.0 55.79 na UG 4.0 60.36 na UG1 4.0 63.0 na SRC 4.0 70.6 na 700.0 The maximum velocity is 26.36 and it occurs in the pipe between nodes 12T and 12 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams MA FIRE SPRINKLERS Page 6 ISIS SYSTEM UPGRADE Date 7-1-11 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C or Ftngs Pe Pv Notes Point Qt P1/Ft Eqv. Ln. Total Pf Pn Si 57,60 2.703 0.0 8.000 11.755 K Factor = 16.80 to 120.0 0.0 0.0 0.0 S2 57.6 0.0091 0.0 8.000 0.073 Vel = 3.22 S2 57.78 2.703 0.0 8.000 11.828 K Factor = 16.80 to 120.0 0.0 0.0 0.0 S3 115.38 0.0332 0.0 8.000 0.266 Vel = 6.45 S3 58.42 2.703 0.0 8.000 12.094 K Factor = 16.80 to 120.0 0.0 0.0 0.0 S4 173.8 0.0707 0.0 8.000 0.566 Vel = 9.72 S4 59.78 2.703 iT 18.651 4.330 12.660 K Factor = 16.80 to 120.0 0.0 18.651 0.0 lOT 233.58 0.1222 0.0 22.981 2.808 Vel = 13.06 0.0 233.58 15.468 K Factor= 59.39 S5 57.75 2.703 0.0 8.000 11.818 K Factor = 16.80 to 120.0 0.0 0.0 0.0 S6 57.75 0.0092 0.0 8.000 0.074 Vel = 3.23 S6 57.94 2.703 0.0 8.000 11.892 K Factor = 16.80 to 120.0 0.0 0.0 0.0 S7 115.69 0.0332 0.0 8.000 0.266 Vel = 6.47 S7 58.58 2.703 0.0 8.000 12.158 K Factor = 16.80 to 120.0 0.0 0.0 0.0 S8 174.27 0.0711 0.0 8.000 0.569 Vel = 9.74 S8 59.93 2.703 iT 18.651 3.670 12.727 K Factor = 16.80 to 120.0 0.0 18.651 0.0 lOT 234.2 0.1228 0.0 22.321 2.741 Vel = 13.09 0.0 234.20 15.468 K Factor= 59.55 S9 57.70 2.703 0.0 8.000 11.796 K Factor = 16.80 to 120.0 0.0 0.0 0.0 S10 57.7 0.0092 0.0 8.000 0.074 Vel = 3.23 S10 57.88 2.703 0.0 8.000 11.870 K Factor = 16.80 to 120.0 0.0 0.0 0.0 Sil 115.58 0.0332 0.0 8.000 0.266 Vel = 6.46 S1I 58.53 2.703 0.0 8.000 12.136 K Factor = 16.80 to 120.0 0.0 0.0 0.0 S12 174.11 0.0710 0.0 8.000 0.568 Vel = 9.73 S12 59.87 2.703 iT 18.651 4.330 12.704 K Factor = 16.80 to 120.0 0.0 18.651 0.0 liT 233.98 0.1226 0.0 22.981 2.817 Vel = 13.08 0.0 233.98 15.521 KFactor= 59.39 S13 57.85 2.703 0.0 8.000 11.859 K Factor = 16.80 to 120.0 0.0 0.0 0.0 S14 57.85 0.0092 0.0 8.000 0.074 Vel = 3.23 S14 58.04 2.703 0.0 8.000 11.933 K Factor = 16.80 to 120.0 0.0 0.0 0.0 S15 115.89 0.0334 0.0 8.000 0.267 Vel = 6.48 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams AAA FIRE SPRINKLERS Page 7 ISIS SYSTEM UPGRADE Date 7-1-11 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv ******* Notes Point Qt PfIFt Eqv. Ln. Total Pf Pn S15 58.68 2.703 0.0 8.000 12.200 K Factor = 16.80 to 120.0 0.0 0.0 0.0 S16 174.57 0.0714 0.0 8.000 0.571 Vet = 9.76 S16 60.04 2.703 11 18.651 3.670 12.771 K Factor = 16.80 to 120.0 0.0 18.651 0.0 liT 234.61 0.1232 0.0 22.321 2.750 Vet = 13.12 0.0 234.61 15.521 KFactor= 59.55 S17 58.06 2.703 0.0 8.000 11.944 K Factor = 16.80 to 120.0 0.0 0.0 0.0 S18 58.06 0.0094 0.0 8.000 0.075 Vet = 3.25 S18 58.24 2.703 0.0 8.000 12.019 K Factor = 16.80 to 120.0 0.0 0.0 0.0 S19 116.3 0.0336 0.0 8.000 0.269 Vel = 6.50 S19 55.89 2.703 0.0 8.000 12.288 K Factor = 16.80 to 120.0 0.0 0.0 0.0 S20 175.19 0.0718 0.0 8.000 0.574 Vel = 9.80 S20 60.26 2.703 iT 18.651 4.330 12.862 K Factor = 16.80 to 120.0 0.0 18.651 0.0 12T 235.45 0.1241 0.0 22.981 2.851 Vet = 13.16 0.0 235.45 15.713 K Factor = 59.40 S21 58.22 2.703 0.0 8.000 12.008 K Factor = 16.80 to 120.0 0.0 0.0 0.0 S22 58.22 0.0094 0.0 8.000 0.075 Vet = 3.26 S22 58.39 2.703 0.0 8.000 12.083 K Factor = 16.80 to 120.0 0.0 0.0 0.0 S23 116.61 0.0338 0.0 8.000 0.270 Vet = 6.52 S23 59.05 2.703 0.0 8.000 12.353 K Factor = 16.80 to 120.0 0.0 0.0 0.0 S24 175.66 0.0721 0.0 8.000 0.577 Vet = 9.82 S24 60.41 2.703 iT 18.651 3.670 12.930 K Factor = 16.80 to 120.0 0.0 18.651 0.0 12T 236.07 0.1247 0.0 22.321 2.783 Vel = 13.20 0.0 236.07 15.713 KFactor= 59.55 S25 66.51 2.703 0.0 8.000 15.673 K Factor = 16.80 to 120.0 0.0 0.0 0.0 S26 66.51 0.0120 0.0 8.000 0.096 Vet = 3.72 S26 66.71 2.703 0.0 8.000 15.769 K Factor = 16.80 to 120.0 0.0 0.0 0.0 S27 133.22 0.0432 0.0 8.000 0.346 Vet = 7.45 S27 67.44 2.703 0.0 8.000 16.115 K Factor = 16.80 to 120.0 0.0 0.0 0.0 S28 200.66 0.0922 0.0 8.000 0.738 Vel = 11.22 S28 68.97 2.703 iT 18.651 3.670 16.853 K Factor = 16.80 to 120.0 0.0 18.651 0.0 13T 269.63 0.1594 0.0 22.321 3.558 Vet = 15.08 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams AAA FIRE SPRINKLERS Page 8 ISIS SYSTEM UPGRADE Date 7-1-11 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv ******* Notes Point Qt Pt/Ft Eqv. Ln. Total Pt Pn 0.0 269.63 20.411 KFactor= 5968 S29 75.26 2.703 IT 18.651 4.330 20.066 K Factor = 16.80 to 120.0 0.0 18.651 0.0 13T 75.26 0.0150 0.0 22.981 0.345 Vel = 4.21 0.0 75.26 20.411 K Factor = 16.66 lOT 467.78 2.703 IT 18.651 2.000 15.468 to 120.0 0.0 18.651 0.866 10 467.78 0.4417 0.0 20.651 9.122 Vel = 26.15 0.0 467.78 25.456 K Factor = 92.71 liT 468.59 2.703 IT 18.651 2.000 15.521 to 120.0 0.0 18.651 0.866 11 468.59 0.4432 0.0 20.651 9.152 Vel = 26.20 0.0 468.59 25.539 K Factor = 92.72 12T 471.52 2.703 IT 18.651 2.000 15.713 to 120.0 0.0 18.651 0.866 12 471.52 0.4483 0.0 20.651 9.257 Vel = 26.36 0.0 471.52 25.836 KFactor= 92.77 13T 344.89 2.703 IT 18.651 2.000 20.411 to 120.0 0.0 18.651 0.866 13 344.89 0.2514 0.0 20.651 5.191 Vel = 19.28 0.0 344.89 26.468 K Factor = 67.04 10 467.78 6.357 0.0 12.000 25.456 to 120.0 0.0 0.0 0.0 11 467.78 0.0069 0.0 12.000 0.083 Vel = 4.73 11 468.59 6.357 0.0 12.000 25.539 to 120.0 0.0 0.0 0.0 12 936.37 0.0247 0.0 12.000 0.297 Vel = 9.47 12 471.52 6.357 0.0 12.000 25.836 to 120.0 0.0 0.0 0.0 13 1407.89 0.0527 0.0 12.000 0.632 Vel = 14.23 13 344.88 6.357 2E 35.205 55.250 26.468 to 120.0 0.0 35.205 0.0 TR 1752.77 0.0790 0.0 90.455 7.148 Vel = 17.72 TR 0.0 6.357 1 12.573 13.000 33.616 to 120.0 IT 37.72 50.293 5.630 BR 1752.77 0.0790 0.0 63.293 5.001 Vel = 17.72 BR 0.0 6.357 0.0 22.000 44.247 to 120.0 0.0 0.0 0.0 BF1 1752.77 0.0790 0.0 22.000 1.738 Vel = 17.72 BF1 0.0 6.16 1K 51,645 8.000 45.985 to 140.0 1 4.304 96.117 2.599 BF2 1752.77 0.0692 2E 40.168 104.117 7.210 VeI= 18.87 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams AM FIRE SPRINKLERS Page 9 ISIS SYSTEM UPGRADE Date 7-1-11 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C" or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln, Total Pf Pn BF2 0.0 6.09 1G 4.625 20.000 55.794 to 150.0 iT 46.249 50.874 0.0 UG 1752.77 0.0645 0.0 70.874 4.568 Vel = 19.31 UG 0.0 7.98 1G 6.041 94.000 60.362 to 150.0 iT 52.855 58.895 0.0 UG1 1752.77 0.0173 0.0 152.895 2.641 Vel = 11.24 UG1 0.0 7.98 2G 12.081 375.000 63.003 to 150.0 iT 52.855 64.937 0.0 SRC 1752.77 0.0173 0.0 439.937 7.602 Vel = 11,24 700.00 Qa = 700.00 2452.77 70.605 K Factor = 291.90 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 t11CG /Fire & Building I Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Model K17-231 - 168 K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description The 16.8 K-factor, Model K17-231, Standard Response, Standard Cover- age, Upright and Pendent Sprinklers (Ref. Figure 1) are automatic sprin- klers of the frangible bulb type. They are "standard response - spray sprin- klers" which produce a hemispherical water distribution pattern below the de- flector. The 16.8 K-factor, K17-231 Sprinklers were subjected to full scale, high-piled storage, fire tests to qualify their use in lieu of 8.0 or 11.2 K-Factor standard spray sprinklers for the protection of high-piled storage. Higher flow rates can be achieved at much lower pressures with the 16.8 K-factor, K17-231 Sprinklers - mak- ing their use highly advantageous in high density applications, such as the protection of high-piled storage. Applications for the 16.8 K-factor, Model K17-231 Pendent and Upright Sprinklers are expanding beyond the current listings/approvals. For informa- tion regarding research fire tests which may be acceptable to an Authority Having Jurisdiction, please contact the Technical Services Department. WARNING The 16.8 K-factor, Model K17-231 Up- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. right and Pendent Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or manufac- turer should be contacted with any questions. Sprinkler Identification Number TY7151 - Upright, 16.81K TY7251 - Pendent, 16.81K TY7151 is a redesignation for C7151, G1888, and S8040. TY7251 is a redesignation for 07251, G1889, and S8041. Technical Data Approvals UL and C-UL Listed. FM and NYC Ap- proved. (Specific details for laboratory listings and approvals given in Table A. The approvals apply to the service conditions indicated in the Design Cri- teria section.) Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 inch NPT or ISO 7-R3/4 Discharge Coefficients K = 16.8 GPM/psi112 (241,9 LPM/bar1/2) Temperature Ratings Refer to Table A Finish Natural Brass Physical Characteristics Frame ............Bronze Button ............Bronze Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb .......Glass (5 mm dia.) Compression Screw ......... Brass Deflector ............Brass tRegistered trademark of DuPont. Page 1 of 4 JANUARY, 2005 TFP332 Page 2 of 4 TFP332 SPRINKLER FINISH TYPE TEMP. BULB LIQUID NATURAL BRASS UPRIGHT K=16.8 (TY7151) 1550F/68°C Red 1 2, 3, 4 200°F/93C Green 286°F/141°C Blue PENDENT K=16.8 (TY7251) 155°F/68°C Red 1,2,4 200°F/93°C Green 286°F/141°C Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL Listed). Listed by by Underwriters Laboratories, Inc. for use in Canada (C-UL Listed). Approved by Factory Mutual Research Corporation (FM Approved). Approved by the City of New York under MEA 177-03-E. TABLE A LABORATORY LISTINGS AND APPROVALS (Refer to the Design Criteria Section) Design Criteria UL and C-UL Listing Requirements The 16.8 K-factor, Model K17-231 (1Y7151 & TY7251) Sprinklers may be installed in accordance with NFPA 13 standard sprinkler position and area/density flow calculation require- ments for light, ordinary, or extra haz- ard occupancies with a minimum re- sidual (flowing) pressure of 7 psi (0,5 bar) in wet or dry pipe sprinkler sys- tems, or they may be installed in ac- cordance with NFPA 13 standard sprinkler position and area/density flow calculation requirements for high piled storage occupancies (solid piled, palletized, rack storage, bin box, and shelf storage including but not limited to Class l-IV and Group A plastics) with a minimum residual (flowing) pressure of 7 psi (0,5 bar) for wet or dry pipe systems. The following two examples are typical of the types of arrangements permitted by NFPA 13. For all combinations of lesser and greater building heights, lesser and greater storage heights, storage arrangements, commodity classifications, and lesser or greater required design densities, refer to NFPA 13 for specifics. Example 1: NFPA 13 provides ceiling only protection (i.e., no in-rack sprin- klers) criteria using open frame (i.e. no solid shelves) single, double, multiple- row, or portable rack storage (without the need for in-rack sprinkler protec- tion) of cartoned or uncartoned unex- panded Group A or B plastics, or, car- toned expanded Group A or B plastics, with: a storage height of up to 20 feet (6, 1 rn), a maximum ceiling height of 27 feet (8,2 m); a minimum deflector to top of stor- age clearance of 18 inches (457 mm); a minimum design density of 0.60 gpm/ft2 (24,4 mm/mm); a minimum residual (flowing) pres- sure of 7ps1 (0,5 bar); a minimum design area of 2000 ft2 (186 m2) for wet systems or 2600 ft2 (242 m2) for dry pipe systems Example 2: NFPA 13 provides ceiling only protection (i.e., no in-rack sprin- klers) criteria using open frame (i.e. no solid shelves) single, double, multiple- row, or portable rack storage (without the need for in-rack sprinkler protec- tion) of cartoned or uncartoned unex- panded Group A or B plastics, or, car- toned expanded Group A or B plastics, with: a storage height of up to 25 feet (7,6 m); a maximum ceiling height of 30 feet (9,1 m); a minimum deflector to top of stor- age clearance of 18 inches (457 mm); a minimum design density of 0.80 gpm/ft2 (32,6 mm/mm); a minimum residual (flowing) pres- sure of 7 psi (0,5 bar); a minimum design area" of 2000 ft2 (186 m2) for wet systems or 4500 ft2 (418 m2) for dry pipe systems FM Approval Requirements The 16.8 K-factor, Model K17-231 (TY7151) Upright Sprinklers may be installed in accordance with the appli- cable "control mode density/area" guidelines provided by Factory Mutual. (FM guidelines may differ from UL and C-UL Listing criteria.) Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. TFP332 Page 3of4 NPT 5 4 WRENCH 2-3/8' 2-3/8' (60,3 [i (60,3 mm) ..__L... FLAT i;;;!1 - 6 mm) 2 /2' (12,7 mm) N OMINAL MAKE—IN - t PENDENT UPRIGHT CROSS SECTION 1 - Frame 4- Bulb Temperature rating is Pipe thread 2 - Button 5 - Compression Screw indicated on deflector, connections per ISO 3- Sealing Assembly 6 - Deflector' 7/1 can be provided on special request. FIGURE 1 MODEL K17-231 UPRIGHT (TV7151) AND PENDENT(TY7251) SPRINKLERS Installation NOTE Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontal, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 1550F/680C to 3/32 inch (2,4 mm) for the 286°F/14 1°C rat- ing. The Model K17-231 Sprinklers must be installed in accordance with the fol- lowing instructions. With pipe thread sealant applied to the pipe threads, hand tighten the Model K17-231 Sprinkler into the sprinkler fitting. 2. Using the W-Type 8 Sprinkler Wrench (Ref. Fig. 2) applied to the sprinkler-Wrench Flats (Ref. Fig. 1), tighten the Model K17-231 Sprinkler into the sprinkler fitting. NOTE A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 (fIbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprin- kler inlet with consequent leakage or impairment of the sprinkler. Care and Maintenance The Model K17-231 Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection systems must be obtained from the proper authori- ties and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). RECESS FIGURE 2 W- TYPE 8 SPRINKLER WRENCH The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Page 4 of 4 TFP332 Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. Ordering Procedure When placing an order, indicate the full product name. Please specify the Sprinkler Identification Number (SIN), quantity, and temperature rating. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (specify SIN), 16.8 K-factor, Model K17-231,(specify temperature rating), (specify Pendent or Upright) Sprinkler, P/N (specify). Upright (SIN TY7151) 155F/68°C ..............PSN 51-888-1-155 200°F/93°C ..............PSN 51-888-1-200 286°F/141C .............PSN 51-888-1-286 Pendent (SIN TY7251) 155°F168°C ..............PSN 51-889-1-155 200°F193°C ..............PSN 51-889-1-200 286°F/141*C .............PSN 51-889-1-286 Sprinkler Wrench: Specify: W-Type 8 Sprinkler Wrench, P/N 56-892-1 -001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 G1JVi!ii —Submittal Sheet 7400 1~ ) A!W! l FIG. 7400 Rigidlite® Coupling k~o APPROVED Fa hti.govS Sb The Fig. 7400 Rigidlite Coupling from Gruvlok is specially designed to provide a rigid, locked-in pipe connection to meet the specific demands of rigid design steel pipe and copper tube systems. Fast and easy swing-over installation of the rugged lightweight housing produces a secure, rigid pipe joint. The Fig. 7400 Rigidlite Coupling is UUULC Listed and FM Approved for 300 psi (20.7 bar) with roll grooved or cut grooved steel pipe prepared in accordance with Gruvlok grooving specifications. Figure 7400 Rigidlite Coupling is available with the Grade E" EPDM, C" Style Gasket intended for use with the Gruvlok Advanced Copper Method. ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval neck track head bolts conforming to ASTM A183 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A563. Bolts and nuts are provided zinc electroplated as standard. METRIC BOLTS & HEAVY HEX NUTS: Heat treated, zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts and bolts are zinc electroplated followed by a yellow chromate dip. STAINLESS STEEL BOLTS & NUTS: Stainless steel bolts and nuts are also available. Contact a Gruvlok Representative for more information. HOUSING: Ductile Iron conforming to ASTM A536, Grade 65-45-12. COATINGS: U Rust inhibiting lead-free paint Color: ORANGE (standard) U Hot Dipped Zinc Galvanized (optional) U Other Colors Available (IE: RAL3000 and RAL9000): For other Coating requirements contact a Gruvlok Representative. GASKETS: Materials Properties as designated in accordance with ASTM 02000 U Grade °E" EPDM (Green color code) NSF-61 Certified -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. U Grade 'T" Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications, air with oil vapors and vegetable and mineral oils, NOT FOR USE IN HOT WATER OR HOT AIR U Grade "0°' Fluoro-Elastomer (Blue color code) -20°F to 300°F (Service Temperature Range)(-29°C to 149°C) Recommended for high temperature resistance to oxidizing acids, petroleum oils, hydraulic fluids, halogenated hydrocarbons and lubricants U Grade °L" Silicone (Red color code) -40°F to 350°F (Service Temperature Range)(-40°C to 177°C) Recommended for dry, hot air and some high temperature chemical services GASKET TYPE: O Standard C Style U Flush Gap (1° - 8') (1W size not available) U "EG" Style LUBRICATION: U Standard Gruvlok U Gruvlok Xtreme (Do Not use with Grade "L") U Other: PROJECT INFORMATION: APPROVAL STAMP: Project: Date: Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: 7/nc-Il PAGE 1OF2 G1JVIII - Submittal Sheet 7400 FIG. 7400 Rigidlite® Coupling FIGURE 7400 RIGICLITE COUPLING Nominal 0.0. Max. Wk. Max. End Range of Coupling_Dimensions Counling Bolts Specified Torque § Approx. X V Z Wy. Size Mm. Max. Size Pressure Load Pi End aralion Sei? e Wt. Ea. In/DN(mm) In/mm PS1ibar &LbsflN In/mm -In/mm Infmm4 !n3/mm 1n/mm ± 4R'L -JNM.. rLbsj*g 1 1.315 300 407 0 -Ye 21/4 4% 11/4 2 %X2Y4 30 45 1.2 25 33.4 20.7 1.81 0 -3.2 57 114 44 M10x57 40 60 0.5 lYe 1.660 300 649 0-Ye 21A 43/4 1% 2 %x2'/e 30 45 1.3 32 42.2 20.7 2.89 0 -3.2 67 121 44 Il410x 57 40 60 0.6 1/2 1.900 300 851 0 -/a 2% 4% 11/4 2 %x2Ye 30 45 1.4 40 48.3 20.7 3.78 0-3.2 73 124 44 - MIx 57 40 60 0.6 2 2.375 300 1,329 0-Ye 3% 5% 1'A 2 %x2% 30 45 1.6 50 60.3 20.7 5.91 0 -3.2 83 140 44 M10x57 40 60 0.7 2% 2.875 300 1,948 0 -Ye 3'/u 6 1% 2 %x2% 30 45 1.9 65 73.0 20.7 8.66 0-3.2 98 152 44 - M10x57 40 60 0.9 30.0. 2.996 300 2,115 0-% 4 5 2 %x2% 30 45 1.9 76.1 76.1 20.7 9.41 0-3.2 102 149 44 M10 x 57 40 60 0.9 3 3.500 300 2,886 0 -% 41h 6A 11/4 2 % x 21/4 30 45 2.1 80 88.9 20.7 12.84 0-3.2 114 171 44 - M10x70 40 60 1.0 4 4.500 300 4,771 0 -'/4 5% 7/4 1/ 2 % x 2/ 30 45 3.1 100 114.3 20.7 21.22 0-6.4 143 197 48 M10x70 40 60 1.4 5 O.D. 5.500 300 7,127 0 -111i 5!4 9Y 2 2 4 x 3 80 100 4.5 139.7 139.7 20.7 31.70 0-6.4 171 235 51 - M12 x 76 110 150 2.0 5 5.563 300 7,292 0-A 6% 9% 2 2 % x 3 80 100 4.6 125 141,3 20.7 32.44 0-6.4 175 235 51 - M12x76 110 150 2.1 640.0. 6.500 300 9.955 0 -% 7-4 U/it 2 2 4 x 3 80 tOO 5.5 165.1 165.1 20.7 44.28 0-6.4 200 264 51 - M12 x 76 110 150 2.5 6 6.625 300 10,341 0-,/, 7'/u 10% 2 2 % x 3 80 100 5.5 150 168.3 20.7 46.00 0-6.4 200 264 51 &412x 76 110 150 2.5 8 8.625 300 17,528 0-1/8 10% 123/4 2% 2 % x 3 80 100 8.4 200 219.1 20.7 77.97 0-3.2 260 324 60 - M12x76 110 150 3.8 For additional details see Coupling Data Chart Notes" on main menu. § For additional Bolt Torque information, on main menu. Not for use in copper systems: See installation & Assembly directions on main menu. Other sizes available, contact a Gruvfok Representative for more information. 7/05-12 PAGE 2OF2 FIGURE 7450 901/2ELBOW SHORT PATTERN FITTINGS - PRESSURE 18 14 DROP 81nch 'a -4inch 12 3inch 2 10 2h inch 2incl, 8 6 4 0 5 10 15 20 Flow Rate (ft./sec.) For Fig. 7450 900 grooved end elbows use the value shown. NOTE: Above values are shown for Schedule 40 pipe to be consistent with industry practices. 16 le ..... j 77. ,- . - - warn hflfll S Ui fl r ..• - ,1 fl ------- ;1_i_4; 0 -- FIGURE1& II'W,.w Nominal O.D. Center Approx. Size to End WI. Ea. lnVN(nith). Alu/thm hi,1(g 2 2.375 2% 1.7 50 503 70 0.8 2 2.875 3 2.6 65 730 76 12 3 3.500 3% 3.5 80 88.9 86 16 4 4.500 4 6.5 100 114.3 102 3.0 6 6.625 5 14.8 150 168.3 140 87 8 8.625 6% 25.6 200 219.1 175 uS FIGURE 7460 TEE SHORT PATTERN FITTINGS - PRESSURE DROP 18 16 -81nch 14 CL CL --6 Inch ---.41nch 12 -31nch Inch 2Inch -. . 1.1 8 o .. .. .. 5 10 15 20 Flow Rate (ttJ8ec.) For Fig. 7460 Tee branch use 21I2 times the value shown. For Fig. 7460 Tee run use the value shown. NOTE: Above values are shown for Schedule 40 pipe to be consistent with industry practices. ..9-.•:;: ;; 2 io 2'/2 _ . w. . .,n °. '° •°•. ,0. - .s0,S%SIi U. :J_ ••L . J; ; :; - TEE FIGURE 7460 Nominal 0.0. Center Approx. Size to End WI. Ea. InjVN(miñ), V14*M-211 IM thtñIII 2 2.375 2% 2.5 50 60.3 70 2', 2.875 3 3.5 65 73.0 76 1.6 3 3.500 3% 4.8 80 88.9 86 2.2 4 4.500 4 8.1 100 114.3 102 3/ 6 6.625 5,4 19.1 150 168.3 140 8.7 8 8.625 61/8 35.2 200 219.1 175 15.0 - Submittal Sheet 7450 & 7460 GRUVLOK® FIRE-RITETM SHORT PATTERN FITTINGS LI FIG. 7450 900 Short Pattern Elbow The Gruvlol Fire-RiteTM short pattern 900 elbows in 2 to 8' size range with a 300 psi pressure rating. Fire-Rite TM fittings are painted to industry specification and are available galvanized for more corrosive environments. CAD designed increased internal diameters provides superior flow capability, APPROVED FaISqWwS OSS. C TO E O.D. LI FIG. 7460 Short Pattern Tee The Gruvlok Fire-Rite1M short pattern fitting tees in 2' to 8' size range with a 300 psi pres- sure rating. Fire-Rite1M fittings are painted to industry specification and are available galvanized for more corrosive environments. CAD designed increased internal diameters provides superior flow capability 7105 -49 PAGE 15 OF 19 tJV — Submittal Sheet 7001 FIG. 7001 Standard Coupling The Gruvlokw Fig. 7001 Standard Coupling forms a flexible grooved end pipe joint Connection with the versatility for a wide range of applications. Services include mechanical and plumbing, process piping, mining and oil field piping, and many others. The coupling design supplies optimum strength for working pressures to 1000 PSI (69 bar) without excessive casting weight. The flexible design eases pipe and equipment installation while providing the designed-in benefit of reducing pipeline noise and vibration transmission with- out the addition of special components. To ease coupling handling and assem- bly and to assure consistent quality, sizes 1' through 14' couplings have two 1800 segment housings, 16' through 24' sizes have four 900 - segment hous- ings while the 28' OR and 30 O.D. couplings have six 60° segment housings. The 28' O.D. and 30' O.D. are weld-ring couplings. k~19 APPROVED F SIlMgFWOS 4I. yo.,OnMot R.fls,u.t ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval neck track head bolts conforming to ASTM A183 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A563. Bolts and nuts are provided zinc electroplated as standard. METRIC BOLTS & HEAVY HEX NUTS: Heat treated, zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts are zinc electroplated followed by a yellow chromate dip. STAINLESS STEEL BOLTS & NUTS: Stainless steel bolts and nuts are also available. Contact a Gruvlok Representative for more information. HOUSING: Ductile Iron conforming to ASTM A536, Grade 65-45-12 or Malleable Iron conforming to ASTM A47, Grade 32510. COATINGS: U Grade °O" Fluoro-Elastomer (Blue color code) -20°F to 300°F (Service Temperature Range)(-29°C to 149°C) Recommended for high temperature resistance to oxidizing acids, petroleum oils, hydraulic fluids, halogenated hydrocarbons and lubricants U Grade "L" Silicone (Red color code) -40°F 10350°F (Service Temperature Range)(-40°C to 177°C) Recommended -for dry, hot air and some high temperature chemical services U Other: GASKET TYPE: U Standard C Style U Flush Gap (1'- 14), (11/4' size not available) U "EG" Style LUBRICATION: U Standard Gruvlok U Gruvlok XtremeT° (Do Not use with Grade "L") U Other: WORKING PRESSURE, END LOAD, PIPE END SEPARATION & DEFLECTION FROM CENTER LINE: Based on standard wall steel pipe with cut or roll grooves in accordance with Gruvlok specifications. See technical data section for design factors. U Rust inhibiting lead-free paint Color: ORANGE (standard) U Hot Dipped Zinc Galvanized (optional) U Other Colors Available (IE: RAL3000 and RAL9000): For other Coating requirements contact a Gruvlok Representative. GASKETS: Materials Properties as designated in accordance with ASTM 02000 Fig. 7001 with Fig. 7001 with Standard Gasket "Flush Gap" Gasket (1"-14") PROJECT INFORMATION: APPRj Project: Date: Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: 7I05- PAGE 1OF2 U GRADE "E" EPDM (Green color code) NSF-61 Certified -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. U Grade T" Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. Air with oil vapors and vegetable and mineral ails. NOT FOR USE IN HOT WATER OR HOT AIR 11 FIG. 7001 Standard Coupling SIZES 16"- 24" SIZES 28° - 30* SIZES 1"- 14 - Submittal Sheet 7001 FIGURE Nominal Max. Wart. Max. End Range Of Pipe End Deflection from Coupling Dimensions Boll Dimensions* Specified Torque § Approx. Per Coupling at Pipe. X Y Z Qiy. Size Mm. Max. Size Pressure Load Separation Wt. Ea. In ,VN(mm) In.04irn PSlit,ar ' 11 Lbs itN In Anth' ' O.gi'..s In itt mm/ni In /mi °id°Aoi7ñ,. fliI°Jmm .-° 'InJmm FJ'L)1WM °° Lbs frN 1 1.315 1000 1,358 06 5° 26' 1.14 2% 4½ 1% 2 /8 x 24 30 45 1.3 25 33.4 68.9 5.04 0-32 94.7 64 114 48 M10x57 40 60 0.6 1% 1.660 1000 2,164 0-4 40 19 0.90 2% 4½ 1% 2 %x2V4 30 45 1.4 32 42.2 68.9 9.63 0-32 75.3 70 174 48 M10x57 40 60 0.6 14 1.900 1000 2,835 0-4 3° 46' 0.79 3 4% 11/8 2 % x 24 30 45 1.5 40 48.3 68.9 72.61 0-32 65.7 76 117 48 M10x57 40 50 0.7 2 2.375 1000 4,430 0-1/8 3°1' 0.63 31A 6% 11/8 2 ½x3 80 100 3.1 50 1 60.3 68.9 19.71 0-32 1 52.6 92 156 48 M12x76 110 150 1.4 2½ 2.875 1000 6,492 0-'/s 2029 0.52 41/4 6½ 17/8 2 %x3 80 100 3.7 65 73.0 68.9 28.88 0-32 43.3 108 765 48 M12x76 110 150 1 1.7 30.0. 2.996 7000 1.050 0-7 2023 0.50 4% 8/ 1% 2 'x3 80 100 4.3 76.1 76.1 68.9 3136 0-32 41.6 108 1 171 48 1 M12 x 761 110 150 2.0 3 3.500 1000 9,621 0-1/8 2° 3' 0.43 4% 7% 1% 2 V x 3 80 100 4.3 80 88.9 68.9 42.80 0-32 _____ 35.8 124 181 48 M12x76 110 150 2.0 3½ 4.000 1000 12,566 0-1/8 1° 48 0.38 51/4 81/4 11/5 2 % x 3½ 100 130 5.1 90 701.6 68.9 55.90 0-32 1 37.4 133 210 48 M16x89 135 175 2.3 4 4.500 1000 15,904 0-/4 3° 11' 0.67 61/4 81/4 2 2 5/sx3V2 100 130 6.8 100 714.3 68.9 70.75 0-6.4 __ 55.5 159 222 51 M16x89 135 175 3.1 5 5.563 1000 24,306 0-h 2° 35' 0.54 7% 111/4 2 x 4½ 130 180 9.6 725 147.3 68.9 708.12 0-6.4 ________ 45.1 184 286 51 M20x110 175 245 4.4 6"O.D. 6.500 1000 33,783 0-4 2°12' 0.46 8'15 773/4 2 2 x4'% 130 780 778 165.1 165.1 68.9 14761 0-6.4 38.4 210 298 51 M20 x 110 175 245 5.4 6 6.625 1000 34,472 0-/i 2° 10' 0.45 8% 11/i 2 2 34x4% 130 180 11.8 750 168.3 68.9 153.34 06.4 1 37.8 219 298 51 M20x 110 775 245 5.4 8 8.625 800 46,741 0-4 1040 0.35 11 14% 2% 2 /a X 5½ 180 220 21.7 200 219.7 55.2 207.91 0-6.4 29.1 279 365 60 M22 140 245 1 300 9.8 10 10.750 800 72,610 0-h 1° 20' 0.28 13% 161/8 2% 2 % x 51h 180 220 27.0 250 213.0 55.2 322.99 0-6.4 23.3 333 422 67 M22 140 245 300 12.2 12 12.750 800 102,141 0-1/4 1°7' 0.23 15½ 18% 2% 2 % x 6 180 220 35.0 300 323.9 55.2 454.35 0-6.4 79.5 394 473 67 1 M22 150 245 300 15.9 14 14.000 300 46,181 0-'/i 1°2' 0.22 16'/u 20½ 3 2 7/a x 5% 180 220 37.0 350 355.6 - 20.7 205.43 0-6.4 _ 78.0 410 521 76 M22 140 245 300 16.8 16 16.000 300 60,319 0-Vi 0° 54' 0.19 18% 22% 3 4 1 x4 200 250 50.0 400 406.4 20.7 268.31 0-6.4 15.7 460 581 76 - - 22.7 18 18.000 300 76,341 0-Vi 0° 48' 0.17 21% 25% 3% 4 1 x4 200 250 72.0 450 457.2 20.7 339.58 0-6.4 14.0 537 645 79 ' - - 32.7 20 20.000 300 94,248 0-1h 0° 43' 0.15 23 28% 3¼ 4 1/aX 4½ 225 275 82.0 500 508.0 20.7 419.23 0-6.4 12.5 584 1 718 79 1 372 24 24.000 300 135,717 0-'/i 0° 36' 0.13 27 32% 3% 4 1% x 41/2 225 275 90.0 600 609.6 20.7 603.70 0-6.4 10.5 686 822 79 1 . . 40,5 28'O.O. 28.875 150 98,226 0-4 0°33' 0.12 33% 35% 3% 6 1x5h 200 250 105.0 733.4 733.4 10.3 436.93 0-6.4 9.6 851 902 79 * - - 47.6 300.D. 37.00 750 713,275 0-Y 0128' 0.10 33-4 384 3'4 6 1x5'h 200 250 137.0 787.4 787.4 1 10.3 503.61 1 0-6.4 1 8.1 857 972 92 - ° - - 62.1 Available in ANSI or metric boil sizes only as indicated. For additional details see"Coupling Data Chart Notes on main menu. § For additional Bolt Torque information, on main menu. See Installation & Assembly directions on main menu. Not for use in copper systems. 7/05-4 PAGE 2OF2 Description FPPI® TrimFit4 Bronze Globe Valves are precision cast then machined using state of the art facilities. Each valve features a full floating seat holder for reduced seat wear when closing the valve. Seat is made of pure virgin PTFE for longer seat life and reduced maintenance as compared to rubber seat valves. Trim- Fit trim valves are suitable for use in regular (1 75psi) and high pressure (300ps1) sprinkler systems. Standard configuration is FNPT x FNPT and is available in 1/4" IPS through 2" IPS sizes. Each valve carries the UL Listing and is rated for use to 300p5i. UL/ULC Listed 2R97 wr r'7'7 r 17 ULIULC Listed 300'psi Installation Install in accordance with usual Thread Sealing Paste with and customary installation PTFE. DO NOT OVERTIGHT- techniques for fire sprinkler EN. OVERTIGHTENING MAY systems. Use a suitable thread CAUSE CRACKS OR LEAKS. sealant on the male threads of the pipe being threaded PipeFit®, TrimFit® , and FPPI® into the valve body. We rec- are registered trademarks of ommend either PTFE Thread Fire Protection Products, Inc. Sealing Tape or PipeFit® Fire Protection Products, Inc 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 01995-2007 Fire Protection Products, Inc (FPPI) For questions: 1 800 344-1822 • 1 800 344-3775 fax www.fppi.com MODEL 1000 3/4" 1" 11/4" 11/2" 1 2" l• The AGF Manufacturing Inc. Model 1000 TESTANDRAIN Provides Both The Test Function And The Express Drain Function For A Wet Fire Sprinkler System. 1• The Model 1000 Complies With All Requirements Of NFPA-13, NFPA-13R, And NFPA-13D. The Model 1000 TESTANDRAIN Is A Single Handle Ball Valve That Is Light Weight And Compact, Includes A Tamper Resistant Test Orifice, Integral Tamper Resistant Sight Glasses, And Is 300 PSI Rated. l• Available In A Full Range Of Sizes From 3/4" To 2" NPT & BSPT, With All Specifiable Orifice Sizes /8", 7/1o", 1/2", 17/32", /" (ELO), 3/4" (ESFR) and K.25. t• The Orifice Size Is Noted On The Indicator Plate And The Valve Is Tapped For A Pressure Gauge. LI The Standard Model 1000 TESTANDRAIN Valve Includes A Pressure Gauge Port Tapping And Can Be Ordered With A Relief Valve As A Model 1011 Or 1011 T Q Locking Kit Available Which Provides Superior Vandal Resistance And Prevents Unintentional Alarm Activation. our New AU,OC Visit us çcs on the Internet at / MODEL 1000 300 PSI (Ij)4i> TMTmDRAIN, 3/4" 1" 11/4" 11/2" 2" PLAN VIEW FRONT VIEW/VERTICAL INSTALLATION FRONT VIEW/HORIZONTAL INSTALLATION ORIFICE SIZE AVAILABLE - 3/8", 17/16", 1/2", 17/32", ELO(5/8'), ESFR(3/4') and K.25 *Available on 11/2' to 2' size units only. DIMENSIONS - INCHES FROM BRANCH GAUGE INLET / PROVIDED STREET EL 0 TO DRAIN I - STREL ORPET E IPE '--Z5 TO DRAIN RIGHT HAND/STRAIGHT INSTALLATION APPROVALS: 13 UL and ULCListed '3 FM Approved except 3/4" '3 NYC-BSA NO. 720-87-SM '3 CA. State Fire Marshall SIZE A B C D E F G H 3/4" 5 1/' 1 1/211 2 I16" 35l8' 3 /" 1 13/16" 4 I16" 6 /8" 128mm 37.58mm 55.65mm 93.23mm 85.88mm 45.30mm 117.12mm 162.42mm if 5 1/16" 1 1/2" 2 3/16" 3 54' 3 /&' 1 13/1611 49/16 It 63/all 128mm 37.58mm 55.65mm 93.23mm 85.88mm 45.30mm 117.12mm 162.42mm 1 1! " 5 /16" 1 11/1611 2 I16" 4 1/4" 3 'io" 1 15/1611 5 I16" 5 1,'l 1 4 137.70mm 42.70mm 65.36mm 108.36mm 82.84mm 50.89mm 141.39mm 192.28mm 1 1/ tl 6 /16" 1 l3," 3 1/4"5 1/u" 3 /8" 25/8" 8 1/411 1074' I 2 163.38mm 45.50mm 81.50mm 127mm 99.18mm 66.97mm 206.63mm 273.60mm 2" 6 /16" 1 13/1611 3 1/4" 5 1/1611 3 7/511 2 /8" 8 1/411 107/811 163.38mm I 45.50mm 81.50mm I 127mm 99.18mm 66.97mm 206.63mm 273.60mm MATERIAL LIST PART: MATERIAL: HANDLE STEEL STEM ROD BRASS BALL C.P. BRONZE BODY BRONZE SIGHT GLASS LEXAN VALVE SEAT IMPREGNATED TEFLON INDICATOR PLATE STEEL HANDLE LOCK SPRING STEEL **3/4" Valve UL listed only. USA PATENT AND OTHER PATENTS PENDING IJIU1oIRLeI*.CI,SL AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 T: (610) 240-4900 IF: (610) 240-4906 Email: Into@testandraln.com Web: www.testandraln.com aRi..PACK and TEST.,,ORAIN .r. regiVured trademarks of AGF JOB NAME: ARCHITECT: ________ ENGINEER : il MADE IN U.S.A. CONTRACTOR: 3/02 Dyna-Flow Specifications NIPS Nominal I.D. Wt. Wt. (H20 Filled) CRR Mrnthtei?e'T'~l 1.191 0.830 1.31 2.41 1i4 1.536 3t 1.059 1.87 1.55 8 MUM 5.1 1½ 1.728 1.667 2.71 3.44 2 2.203 2.104 3.79 2.78 21h" 2.703 ______ 2.564 5.10 1.60 wp 3J 3.314 3.387 7.18 1.48 4.310 6MENFiRRVs1IM RUMOR! 4.473 10.86 R 1.00 VP P1 0 VI 0 Dyna-Flow is the 'original" high-strength light wall sprinkler pipe. With outstanding hydraulic capabilities, Dyna-Flow is recognized as the most popular alternative to Schedule-lO pipe. Lightweight and easy to cut, Dyna-Flow is a valuable addition to any fire protection system. With an inside diameter (ID) up to 11% larger than Schedule-40 and up to 7% larger than Schedule -10, Dyna-Flow pipe hydraulics are exceptional. Larger ID's enable Dyna-Flow and related components to be down-sized within the system, increasing the potential for job cost savings. For complete Hazen Williams charts, refer to "Dyna-Flow Hydraulic Data Tables". Dyna-Flow pipe has metallurgical properties that provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There are no special processes or equipment needed for fabrication and installation. ® Superior Coating Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable and acts as an excellent primer while resisting weather and UV degradation from outdoor storage. ® American Made Able to meet "Buy American" requirements, and is available through distributors in the USA, Canada, Mexico and Latin America. Specifications & Approvals Dyna-Flow pipe is manufactured to meet ASTM A-795 Type E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna-Flow are UL and cUL listed and FM approved. Dyna-Flow is UL and cUL listed for use with roll grooved, plain-end and welded joints for wet, dry, pre-action and deluge systems. It is FM approved for roll grooved, plain end and welded joints for wet systems. Dyna-Flow is available "hot-dip" galvanized** and has been specifically approved by FM for dry system uses. Dyna-Flow complies with NFPA 13 and is rated at 300 psi working pressure. Exceptional hydraulics Lightweight and easy to install Available factory roll grooved UL and cUL listed FM approved ® The original high-strength light wall sprinkler pipe with superior hydraulics. must be ordered in 10 bundle increments : When you specify Allied Schedule-10fSchedule-40 sprinkler pipe you get a UL listed and FM approved product. . Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-1O (1¼"— 8") pipe and Sch-40 (1"— 2½") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. ® Galvanized Pipe Schedule-10/Schedule-40 product can be hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123, ® Superior Coating Our advanced formula mill coating offers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all Allied Tube & Conduit Fire Sprinkler pipe products up to 4.500" in diameter is coated with our new Antibacterial Formula, "ABFll". In scientific laboratory tests, ABFll proved to have superior resistance to microbial colonization of pipe walls, thereby inhibiting or possibly preventing the onset of Microbiologically Influenced Corrosion (MIC) upon installation and the first 25 flushes of the fire sprinkler system.* ® American Made Meets "Buy American" requirement and is available through distributors in the USA, Canada, Mexico and Latin America. ® Specifications & Approvals Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. All pipe products have a rated working pressure of 300 psi maximum and also meet the stringent requirements for the following applications and tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture - Specifications- NPS Nominal I.D. Wt. WI. (H20 Filled) CRR 1' 1.049 1.680 2.05 1 Ths AMJ 11/4 2.270 2.93 1 46 NG 1½" 1.610 2.720 3.61 1 2" 2.067 3.650 . 5.13 1 525 5"O 21h" 2.469 5.790 7.86 1 r0 Specifications NPS Nominal I.D. Wt. Wt. (H20 Filled) CRR iT kim 77 11/4" 1.442 1.810 2.525 7.0955 W7 Zik 1½" 1.682 2.080 3.04 5.6570 oi TZ M7 2.157 2.640. . 4.22 4.5827 21h" 2.635 3.530 5.89 3.5196 RUHR 'EMPRE.-TWER00 233 3.260 4.330 7.94 2.5550 4.260 5.610 11.78 1.6020 __ ________ OW 5.295 7.77 17.33 1.4874 4Ti 1(5 6' 6.357 9.290 23.03 1.0251 8" 8.249 16.490 40.15 1.8365 2L 95T APPIOVID * See ABFII warranty When you specify Allied Schedule-1O/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-1 0 (1'/4"— 8") pipe and Sch-40 (1"— 21/2") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. : ® Galvanized Pipe Schedule-1O/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc,çoating specifications of ASTM A-123. ® Superior Coating Our advanced formula mill coating offers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all Allied Tube & Conduit Fire Sprinkler pipe products up to 4.500" in diameter is coated with our new Antibacterial Formula, "ABFII In scientific laboratory tests, ABFII proved to have superior resistance to microbial colonization of pipe walls, thereby inhibiting or possibly preventing the onset of Microbiologically Influenced Corrosion (MlC) upon installation and the first 25 flushes of the fire sprinkler system.* ® American Made Meets "Buy American" requirement and is available through distributors in the USA, Canada, Mexico and Latin America. ® Specifications & Approvals Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. All pipe products have a rated working pressure of 300 psi maximum and also meet the stringent requirements for the following applications and tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture Sch-40 Specifications NIPS Nominal I.D. Wt. Wt. (1120 Filled) CRR imrn /Ek thfl L 1.049 1.680 2.05 1 11/4 1.380 2.270 2.93 1 1470 URNI, IN K~ 1½' 1.610 2.720 3.61 1 2.067 3:650 5.13 1 90 525 2½' 2.469 5.790 7.86 1 j'uw - Specifications NPS Nominal I.D. Wt. Wt. (H20 Filled) CRR 11/4 1.810 2.525 7.0955 1½' 1.682 2.080 3.04 5.6570 2.157 2.640 4.22 4.5827 2½' 2.635 3.530 5.89 3.5196 3.260 4.330 7.94 • 2.5550 4.260 5.610 11.78 1.6020 5.295 7.77 17.33 1.4874 '9 W4 6 6.357 9.290 23.03 1.0251 8' • M~ 8.249 MEJj N 16.490 40.15 1.8365 Mind A,,"." * See ABFII warranty VERTICAL MOUNT rIIrjh1.Jt711 !A !ti]ix. - _T r Not lesu thes wood F - I No pre-drilling required. U.Saves time from traditional — 9 For vorscal use. install n Center o Reduces installation cost f lower Ixe .uiT Minimum 2 embedment into base 4 material for NFPA 13 mplrancn • Composite! TrussMade in the U.SA - Consull 0us$ manufacturer for recommended inslaltatron point. Pre.drrtling may be cequ red (or GST 25-380 Toel available on page ID - Rod Part- Mod I Screw Ultimate ULlest FM Test" Box Case Approvals Size Number e Descriptions Pullout (Ibs) Load (Ibs) Load (Ibs) Qty Oly VK FLR ~,M'agjtm 4A -}3;q wj j 1 i l 'JrTL AN 4W 4~f J. vmw 4, u,?mu LG T4I i seL aC VLF1 eriI( VLfl SAMMY Swivel Hea& for Wood #mmoaases up to a 71 X 1Z pitcn TOOT. • Reduces installation cost Allows 17 deflection from vertical. • Made in the U.S.A. Approvals - Rod Part Screw :U Itimate UL Test FMTest Model in Box Case~ Size Number Descriptions Pullout (lbs) Load (lbs) Load (lb*s) Thickness Oty Oty ' 3V 8141957 SH-GST30 114x3 1720 (Fir) 1500 1475 25 125 #14B1 - - Nut Dr SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique son-off feature which provides a fast and safe installation each time. When the face of the driver comes Into f #81 - contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. 11 ~ ~ ~ ~ IffifflMEW". ~, i~ ~~Il (a = WT ii 1HS Fig. 200 - "Trimline" Adjustable Band Hanger C@US um Fig. 200R (Import) - 'Trimline" Adjustable Band Hanger w/Retainer Ring - Size Range - 1/2' thru 8" pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications .; Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. (21h" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. WtJ100 1/2 3/8 8mm or 10mm 3½ 25A 400 11 3/4 3/8 8mm or10mm 31A 21h 400 11 1 3/8 8mm or 10mm 33/8 2% 400 12 11/4 3/8 8mm or 10mm 33/4 27/6 400 13 1½ 3/8 8mm or 10mm 37A 27A 400 14 2 3/8 8mm or 10mm 41h 3 400 15 21h 3/8 10mm 55A 41A 600 27 3 3/8 10mm 57A 4 600 29 3½ 3/8 10mm 73A 51/4 600 34 4 3/8 10mm 73A 5 1000 35 5 1/2 12mm 91A 61/4 1250 66 6 1/2 12mm 101/8 6-Y4 1250 73 8 1/2 12mm 131A 83/4 1250 136 OFFICE/MANUFACTURING FACIUTY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www,tolco.com Fig. 52 - Six Hole Side Beam Bracket Size Range - 3/8 and 1/2' rod, 1/2" thru 31," pipe Material - Carbon Steel Function - Recommended for attaching hanger rod to steel or wood beams. Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod size and finish H3(4) H2 C Dimensions • Weights Rod Hole Size Max. Rec. Approx. Size A B C H-i H-2 H-3 Load Lbs. Wt./100 3/8x1/2 2 13/16 2 9/16 7/16 5/16 700 35 1/2 x 1/2 2 3/4 2 9/16 9/16 5/16 700 34 Fig. 56 -Tapped Side Beam Connector, in Stainless Steel 1@0 UMB Size Range - 1/2" thru 4" pipe (3/8" rod). Material - Stainless Steel G Function - Recommended for attaching hanger rod to steel or wood beams. Tapped hole allows easy adjustment of hanger rod. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL), and Factory Mutual Engineering approved for 1/2" thru 4" pipe. Note - Available only in Stainless Steel materials. Order By - Figure number, rod size and stainless steel finish Note - Per NFPA 13:1/2" thru 2" pipe use 3/8" fastener; 21h" thru B 4" pipe, use 1/2" fastener. '<D Dimensions • Weights Pipe Rod Size Hole Size Approx. Size A B C D G H WtJ100 1/2 -4 3/8 25A 1 11/4 7/16 9/16 20 OFFICEIMANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 A CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 1000 - "Fast Clamp" Sway Brace Attachment Component of State of California OSHPD Approved Seismic Restraints System Size Range - Pipe size to be braced: 1" thru 6" Schedule 10 thru 40 IPS." Pipe size used for bracing: 1" and 11/4" Schedule 40 IPS. Additionally (UL) approved for use to brace Schedule 7 sprinkler pipe up to 4" (maximum horizontal design load 655 lbs.) Torque requirement 6 - 8 ft. lbs. Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace sys- tem: Fig. 1000 is used in conjunction with a TOLCO Fig. 900 Series Fitting and joined together with bracing pipe per NFPA 13* or TOLCO OSHPD Approved Seismic Manual, forming a complete sway brace assembly. Features - Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a 4-way riser brace. Can be used as longitudinal brace with Fig. 907. Comes assembled and individually packaged with illustrated installation instructions - sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been achieved. Installation - The Fig. 1000 is the braced pipe attachment component of a lateral sway brace assembly. It is intended to be combined with the bracing pipe' and TOLCO structural attach- ment component, Fig. 980, 910 or 909 to form a complete bracing assembly. Follow NFPA 13 and/or OSHPD guidelines. To Install - Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through opening leaving a minimum of 1" extension. Brace pipe can be installed on top or bottom of pipe to be braced. Tighten hex nuts until leaf spring is flat. It is recommended that the brace angle be adjusted before hex nuts are fully tightened. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement informa- tion relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Application Note - Position Fast Clamp and tighten two hex nuts until leaf spring flattens. A minimum of 1" pipe extension beyond the Fig. 1000 is recommended. Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Order first by pipe size to be braced, followed by pipe size used for bracing, figure number and finish. Maximum Design Load 1" thru 4" pipe size - 2015 lbs. 6' size - 1265 lbs. FM Approved Design Loads* 1" - 21/2" - 600 lbs. 3" - 4" - 700 lbs. C®U$ US= TOLCO® brand bracing components are desgined to be compatible QIILI with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NQI warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NO be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICEIMANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 980 - Universal Swivel Sway Brace Attachment c®ususTED Size Range - One size fits bracing pipe 1" thru 2", TOLCO 12 gauge channel, and all structural steel up to 1/4" thick. Material - Carbon Steel Component of State of Function - Multi-functional attachment to structure or California OSHPD Approved Seismic Restraints System braced pipe fitting. Features - This product's design incorporates a concen- tric attachment opening which i critical to the performance H of structural seismic connections. NFPA 13 (2010) 9.3.5.8.4 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation - The Fig.980 is the structural or transitional A attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the B "bracing pipe" and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 2002, 4L, 4A or 413 to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install - Place the Fig. 980 onto the "bracing pipe". Tighten the set bolt until set bolt head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Note - The Fig. 980 Swivel Attachment and the Fig. 1001, Fig. 1000, Fig. 2002, Fig. 4A, Fig. 413 or Fig. 4L Pipe Clamp make up a sway brace system of UL Listed attachments and bracing materials which satisfies the require- ments of Underwriters' Laboratories and the National Fire Protection Association (NFPA) Finish - Plain Note - Available in Electro-Galvanized finish. Order By - Figure number and finish. /> Pat. #6,273,372, Pat. #6,517,030, Pat. #6,953,174, Pat. #6,708,930, Pat. #7,191,987, Pat. #7,441,730, Pat. #7,669,806 Dimensions • Weights Lateral Brace Max. Design Max. Design Approx. A B Load Lbs. Load Lbs." wtJloo (cULus) (FM) 51/4 17/8 17/32 2765 2800 132 Available with hole sizes to accommodate up to 3/4" fastener. Consult factory. The loads listed are axial loads on the brace. The horizontal load capacity, H, of the brace is: H = F x sin 0, where 0 is the installation angle measured from the vertical. TOLCO° brand bracing components are desgined to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO° brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5265 www.tolco.com Fig. 4L C®US LISTED Longitudinal "In-Line" Sway Brace Attachment Size Range - 21/2" through 8" IPS. Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbance. Approvals - Underwriter's Laboratories Listed in the USA (UL) and Canada (cLJL) 21/2" - 8". Approved by Factory Mutual Engineering (FM), 21/2" - 8" pipe. Installation Instructions - The Fig. 4L is the "braced pipe' attachment component of a longitudinal sway brace assembly. It is intended to be combined with the 'bracing pipe" and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install - Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage "bracing pipe" into jaw opening and tighten set bolt until hex head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish - Plain Note - Available in Electro-Galvanized and HOG finish. Order By - Figure number, pipe size and finish. Longitudinal Brace 4-Way Riser Brace (Plan view) Dimensions • Weights Bolt Max. Rec. *Max Design Approx. Sizes A C D Size Load Lbs. Load Lbs. wt./100 (cULus) (FM) 21/2 67A6 21/2 2,Y4 1/2 2015 3000 253 3 7 22/4 31/16 1/2 2015 1550 268 4 81h 33A 311A6 1/2 2015 1550 348 5 93/4 37/8 43/6 1/2 2015 1450 380 6 111/2 5 51/6 1/2 2015 1450 640 8 131/4 55/8 5/8 1/2 2015 1450 728 * The loads listed are axial loads on the brace. The horizontal load capacity, H, of the brace is: H = F x sin 0, where 0 the installation angle measured from the vertical. FM approved when used with 1, 11/4", 11/2" or 2" Sch. 40 brace pipe. TOLCO® brand bracing components are designed to be compatible QW,I with other TOLCOO brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCOO brand bracing components, in the instance that such TOLCOa brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICEINIANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www,tolcacom ASUoi F~w~ ~Im~ I - Fire Protection by Computer Design AM FIRE SPRINKLERS 20942 JAPATUL ROAD ALPINE, CA 91901 619-445-9898 Job Name : ISIS SYSTEM PROOF CALC Building Location : 2280 FARADY AVE. System Contract Data File : ISIS SYSTEM UPGRADE.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 , AAA FIRE SPRINKLERS Page 1 ISIS SYSTEM PROOF CALC Date 11-30-11 HYDRAULIC CALCULATIONS for Project name: ISIS SYSTEM UPGRADE Location: 2280 FARADY AVE. Drawing no: Date: 11-30-11 Design V Remote area number: Remote area location: NEAR SOUTHWEST CORNER OF BUILDING Occupancy classification: EXTRA HAZARD Density: .33 - Gpm/SqFt Area of application: 3000 - SqFt V Coverage per sprinkler. 96-SqFt Type of sprinklers calculated: 8.0K SSU No. of sprinklers calculated: 32 In-rack demand: N/A - GPM Hose streams: 500 - GPM Total water required (including hose streams): 155'1.331-GPM © 75.113 - Psi Type of system: WET GRID Volume of dry orpreaction system: N/A - Gal Water supply information Date: 5-24-11 Location: HYDRANTS DIRECTLY ADJACENT TO SITE V Source: AAA FIRE SPRINKLERS WITH THE CARLSBAD FIRE DEPT. Name of contractor: AAA FIRE SPRINKLERS : Address: 20942 JAPATUL RD./ /ALPINE, CA 91901 Phone number: 619-445-9898 Name of designer: MJC Authority having jurisdiction: CARLSBAD FIRE DEPARTMENT Notes: (Include peaking information or gridded systems here.) A 10% REDUCTION HAS BEEN TAKEN PRIOR TO DATA ENTRY. AREA HAS BEEN PEAKED AND PEAKING CALCS ARE INCLUDED. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) 0 AAA FIRE SPRINKLERS . Page 2 ISIS SYSTEM PROOF CALC . .' . Date 11-30-11 City Water Supply: Demand: Cl - Static Pressure : 90.9 ; Dl - Elevation : 9.095 C2 - Residual Pressure: 88.2 0 D2 - System Flow : 1051.33 C2 - Residual Flow : 1471.7 D2 - System Pressure : 75.113 Hose ( Demand) : 500 D3-System Demand : 1551.33 Safety Margin : 12.810 150 140 130 p120 R° E10° : ci C2 S90 ___ ____ ______ p S80 -- D2 U7° -- D3° R60 E5° 40 30 207 10 DI .0• 0 . 0• .. •0 0. 200 400 600 800 1000 1200 1400 1600 1800 FLOW (N"1.85) 0 0 i . Computer Programs by Hydratoo Inc Riuto(bt1i1 PiWtncIharnN HJUS\ 3087 pthtl'4.'.- Flow'Diagram MA FIRE SPRINKLERS Page 3 ISIS SYSTEM PROOF CALC Date 11-30-11 133.1 111.1 69.9 10 4-11 1_FM-12 4-13 -14 267.5 6.8 378.5 FM4-FMI-a.15 t I 62.8 I 374.5 213.2 I 2131.2 117.2 46.9 FM1_ 18 -a. 17 -a. 18 .-a. 19 - 20 -+21 161.6 79.2 20.1 133.1 68.3 4.9 58.5 123 lOT-a. SI $2 S3 S4 S5 - S6 - S7 $8 - S9 - 40T 100.4 36.6 26.8 90.5 156.3 134.4 69.3 5.6 58 122.7 . . 11T_ Sb-a. Sib-a. S12-.a. S13-.a. S144- $154- S164- $174- $184- 41T 101.5 37.4 26.2 90.1 156.1 117.9 53.5 10.1 73.7 138.9 12T-.a. S19-.a. S20+ 521-a. S224- S23 4_ S24 4- S254- S26#- S274- 42T 85.5 21.7 41.8 106 172.9 63.1 9 81.1 13T-a. S28 -+ S294- S304- S31<-. S32 43T 27 45 117.6 69.9 14Ti- 44T 62.8 15T-.a. 45T 51.6 16T-a. 46T 44.4 17T-a. 47T 38 18T-a. 48T 32.3 19T_a. 49T 26.8 20T-a. 50T 20.1 -. 21T-.a.SIT 133.1 lOT4- 10 t C I 133.1 1344 lIT4- 11 117.9 12T+- 12 I 6.8 63. I3T+- 13 t I 69.9 69•1'D • 14T-a.14 62.8 15T 4_ 15 • 1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow' Diagram AAA FIRE SPRINKLERS Page 4 ISIS SYSTEM PROOF CALC Date 11-30-11 51.6 16T1- 16 1 161.6 44.4 17T*- 17 I 117.2 38J 18T1- 18 I 79.2 32.3 19T-. 19 I 46.9 26.e 20T4_20 20.1 2O.. 21Ti-21 156.3 40T_ 40 I 156.3 15.1 41T+- 41 t I 312.4 17.9 42T4-. 42 t I 485.3 11.6 43T+- 43 I 602.9 69. 44T-44 .., 672.8 62. 45T-45 I I 610 51. 46T-) 46 I I 558.3 44. 47T_ 47 I I 513.9 381 48T-+ 48 I 475.9 32. 49T-+49 I .1 443.6 26. 50T-+ 50 I 416.9 20.p 51T-) 51 156.3 485.3 672.8 558.3 475.9 416.9 1051.3 1051.3 1051.3 1051.3 40 - 41 _ 42 i- 43 _ 44 _ 45 - 46 _ 47 -. 48 - 49 50 _ 51 _ FMI4-. TR - BR BFI-. BF24- UG - UG1 SRC 312.4 602.9 610 513.9 443.6 396.7 1051.3 1051.3 1051.3 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary ,AAA FIRE SPRINKLERS Page 5 ISIS SYSTEM PROOF CALC S Date 11-30-11 - Fitting Legend Abbrev. Name 1/2 3h 1 1% 1% 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 139O'FlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zai Ames 4000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. S. -. Q .5 Computer Program by Hydratcc Inc. R'tuteYV1l:f PnaibtF iUSA 03087 r1 9Wi} kU ;r.14t: ti Presáure / Flow Summary - STANDARD AAA FIRE SPRINKLERS Page 6 ISIS SYSTEM PROOF CALC Date 11-30-11 Node Elevation K-Fact Pt Pn Flow Density Area Pres No. Actual Actual Rea. 10 15.0 21.5 na 11 15.0 21.71 na FM 15.0 23.42 na 12 15.0 22.94 na 13 15.0 22.94 na . FM1 15.0 38.94 na 16 15.0 38.07 na - 17 15.0 37.77 na 18 15.0 37.6 na 19 15.0 37.53 na 20 15.0 37.5 na . lOT 17.0 18.75 na . SI 17.0 8 16.7 na 32.69 0.33 96 7.0 S2 17.0 8 16.08 na 32.08 0.33 96 7.0 S3 17.0 8 15.78 na 31.78 0.33 96 7.0 S4 17.0 8 15.68 na 31.68 0.33 96 7.0 S5 17.0 8 15.68 na 31.68 0.33 96 7.0 S6 17.0 8 15.74 na 31.73 0.33 96 7.0 S7 17.0 8 15.96 na 31.96 0.33 96 7.0 S8 17.0 8 16.47 na 32.47 0.33 96 7.0 S9 17.0 8 17.36 na 33.34 0.33 96 7.0 lIT 17.0 18.92 na SIO 17.0 8 16.84 na 32.83 0.33 96 7.0 S1I 17.0 8 16.21 na 32.21 0.33 96 7.0 S12 17.0 8 15.9 na 31.9 0.33 96 7.0 S13 17.0 8 15.8 na 31.8 0.33 96 7.0 ,. S14 17.0 8 15.8 na 31.8 0.33 96 7.0 S15 17.0 8 15.85 na 31.85 0.33 96 7.9 S16 17.0 8 16.07 na 32.07 0.33 96 7.0 S17 - 17.0 8 16.57 na 32.57 0.33 96 7.9 S18 17.0 8 17.47 na 33.43 0.33 96 7.0 12T 17.0 20.57 na S19 17.0 8 16.45 na 32.44 0.33 96 7.0 S20 17.0 8 15.99 na 31.99 0.33 96 7.0 S21 17.0 8 15.8 na 31.8 0.33 96 7.0 S22 17.0 8 15.76 na 31.76 0.33 96 7.0 S23 17.0 8 15.77 na 31.77 0.33 96 7.0 S24 17.0 8 15.89 na 31.89 0.33 96 7.0 S25 17.0 8 16.24 na 32.24 0.33 96 7.0 S26 17.0 8 16.92 na 32.91 0.33 96 7.0 S27 17.0 8 18.04 na 33.98 0.33 96 7.0 13T 17.0 21.6 na S28 17.0 8 20.31 na 36.05 0.33 96 7.0 S29 17.0 8 20.25 na 36.0 0.33 96 7.0 S30 17.0 8 20.26 na 36.01 0.33 96 7.0 S31 17.0 8 20.4 na 36.13 0.33 96 7.0, S32 17.0 8 20.81 na 36.5 0.33 96 7.0 14T 17.0 22.92 na I5T 17.0 37.46 na I6T 17.0 36.87 na I7T 17.0 36.66 na 18T 17.0 36.55 na 19T 17.0 36.52 na 20T 17.0 36.53 na 21T 17.0 36.57 na 40T 17.0 25.85 na 41T 17.0 25.93 na 42T 17.0 25.68 na 43T 17.0 27.86 na 44T 17.0 29.71 na 45T 17.0 31.89 na - Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow' Summary - Standard MA FIRE SPRINKLERS Page 7 ISIS SYSTEM PROOF CALC Date 11-30-11 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 46T 17.0 33.0 na 47T 17.0 33.72 na 481 17.0 34.35 na 49T 17.0 34.9 na 501 17.0 35.38 na 51T 17.0 35.81 na 40 15.0 29.25 na 41 15.0 29.33 na 42 15.0 29.6 na 43 15.0 30.22 na 44 15.0 31.15 na 45 15.0 32.28 na 46 15.0 3354 na 47 15.0 34.34 na 48 15.0 35.03 na 49 . 15.0 35.63 na 50 15.0 36.15 na 51 15.0 36.62 na TR 15.0 46.31 na BR 2.0 54.55 na BFI 2.0 55.16 na BF2 -4.0 69.36 - na UG -4.0 71.13 na UG1 -4.0 72.16 na SRC -4.0 75.11 na 500.0 The maximum velocity is 23.67 and it occurs in the pipe between nodes FMI and TR - Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams AAA FIRE SPRINKLERS Page 8 ISIS SYSTEM PROOF CALC Date 11-30-11 Hd: Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 10 133.12 3.26 0.0 12.000 21.499 to 120.0 0.0 0.0 0.0 11 133.12 0.0173 0.0 12.000 0.208 Vel = 5.12 . 11 134.35 3.26 IT 20.159 7.000 21.707 to 120.0 0.0 20.159 0.0 FM 267.47 0.0631 0.0 27.159 1.713 Vel = 10.28 FM -378.55 3.26 1E 9.408 29.000 23.420 to 120.0 0.0 9.408 0.0 12 -111.08 -0.0124 0.0 38.408 -0.477 Vel = 4.27 12 117.91 3.26 0.0 12.000 22.943 to 120.0 0.0 0.0 0.0 13 6.83 0.0001 0.0 12.000 0.001 Vel = 0.26 13 63.09 3.26 2E 18.815 32.000 22.944 to 120.0 0.0 18.815 6.496 14 69.92 0.0053 0.0 50.815 0.268 Vel = 2.69 0.0 69.92 29.708 KFactor = 12.83 FM 378.54 3.26 1E 9.408 99.920 23.420 to 120.0 IT 20.159 29.567 0.0 FMI 378.54 0.1199 0.0 129.487 15.525 Vel = 14.55 FM1. -441.37 3.26 IT 20.159 15.000 38.945 to 120.0 0.0 20.159 6.496 15 -62.83 -0.0043 0.0 35.159 -0.152 Vel = 2.42 0.0 -62.83 45.289 K Factor= -9.34 FMI -213.23 3.26 IT 20.159 1.000 38.945 to 120.0 0.0 20.159 0.0 - -- 16 -213.23 -0.0415 0.0 21.159 -0.878 Vel = 8.20 16 51.62 3.26 0.0 12.000 38.067 to 120.0 0.0 0.0 0.0 - 17 -161.61 -0.0248 0.0 12.000 -0.298 Vel = 6.21 17 44.41 3.26 0.0 12.000 37.769 . to 120.0 0.0 0.0 0.0 18 -117.2 -0.0137 0.0 12.000 -0.164 Vel= 4.50 18 38.04 3.26 0.0 12.000 37.605 to 120.0 0.0 0.0 0.0 19 -79.16 -0.0067 0.0 12.000 -0.080 Vel = 3.04 19 32.26 3.26 0.0 12.000 37.525 to 120.0 0.0 0.0 0.0 20 -46.9 -0.0025 0.0 12.000 -0.030 Vel = 1.80 20 26.76 3.26 0.0 12.000 37.495 to 120.0 0.0 0.0 6.496 21 -20.14 -0.0005 0.0 12.000 -0.006 Vel = 0.77 0.0 -20.14 43.985 K Factor= -3.04 lOT -133.12 2.157 iT 12.307 3.500 18.745 to 120.0 0.0 12.307 0.0 SI -133.12 -0.1296 0.0 15.807 -2.048 Vel = 11.69 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final' Calculations - Hazen-Williams .AAA FIRE SPRINKLERS Page 9 ISIS SYSTEM PROOF CALC Date 11-30-11 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn SI 32.69 2.157 0.0 8.000 16.697 K Factor =8.00 to 120.0 0.0 0.0 0.0 S2 -100.43 -0.0770 0.0 8.000 -0.616 Vel = 8.82 S2 32.08 2.157 0.0 8.000 16.081 K Factor =8.00 to 120.0 . 0.0 0.0 0.0 S3 -68.35 -0.0378 0.0 8.000 -0.302 Vel = 6.00 S3 31.78 2.157 0.0 8.000 15.779 K Factor 8.00 to 120.0 0.0 0.0 0.0 S4 -36.57 -0.0119 0.0 8.000 -0.095 Vel = 3.21 S4 31.68 2.157 0.0 8.000 15.684 K Factor =8.00 to 120.0 0.0 0.0 0.0 S5 -4.89 -0.0002 0.0 8.000 -0.002 Vel = 0.43 J1.J S5 31.68 2.157 0.0 8.000 15.682 K Factor = 8.00 to 120.0 0.0 0.0 0.0 S6 26.79 0.0066 0.0 8.000 0.053 Vel = 2.35 - S6 31.74 2.157 0.0 8.000 15.735 K Factor = 8.00 to 120.0 0.0 0.0 0.0 S7 58.53 0.0284 0.0 8.000 0.227 Vel = 5.14 S7 31.96 2.157 0.0 8.000 15.962 K Factor =8.00 to 120.0 0.0 0.0 0.0 S8 90.49 0.0634 0.0 8.000 0.507 Vel = 7.94 S8 32.47 2.157 0.0 8.000 16.469 K Factor =8.00 to 120.0 0.0 0.0 0.0 S9 122.96 0.1120 0.0 8.000 0.896 Vel = 10.80 S9 33.33 2.157 iT 12.307 36.330 17.365 K Factor =8.00 - to 120.0 0.0 12.307 0.0 401 156.29 0.1744 0.0 48.637 8.483 Vel = 13,72 0.0 156.29 25.848 KFactor= 30.74 lIT -134.35 2.157 IT 12.307 3.500 18.921 to 120.0 0.0 12.307 0.0 SIO -134.35 -0.1318 0.0 15.807 -2.084 Vel = 11.80 S10 32.83 2.157 0.0 8.000 16.837 K Factor =8.00 to 120.0 0.0 0.0 0.0 Sill -101.52 -0.0785 0.0 8.000 -0.628 Vel = 8.91 SI1 32.20 2.157 0.0 8.000 16.209 K Factor = 8.00 to 120.0 0.0 0.0 0.0 S12 -69.32 -0.0388 0.0 8.000 -0.310 Vel = 6.09 S12 31.90 2.157 0.0 8.000 15.899 K Factor 8.00 to 120.0 0.0 0.0 0.0 S13 -37.42 -0.0124 0.0 8.000 -0.099 Vel = 3.29 S13 31.80 2.157 0.0 8.000 15.800 K Factor =8.00 to 120.0 0.0 0.0 0.0 S14 -5.62 -0.0004 0.0 8.000 -0.003 Vel = 0.49 S14 31.80 2.157 0.0 8.000 15.797 K Factor = 8.00 to • 120.0 0.0 0.0 0.0 S15 26.18 0.0064 0.0 8.000 0.051 Vel = 2.30 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams AAA FIRE SPRINKLERS Page 10 ISIS SYSTEM PROOF CALC Date 11-30-11 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or . Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1 S15 31.85 2.157 0.0 8.000 15.848 KFactor=8.00 to 120.0 0.0 0.0 0.0 S16 58.03 0.0279 0.0 8.000 0.223 Vel = 5.09 .S16 32.07 2.157 0.0 8.000 16.071 K Factor =8.00 to 120.0 0.0 0.0 0.0 S17 90.1 0.0630 0.0 8.000 0.504 Vel = 7.91 S17 32.57 2.157 0.0 8.000 16.575 K Factor = 8.00 to 120.0 0.0 0.0 0.0 S18 122.67 0.1114 0.0 8.000 0.891 Vel = 10.77 S18 33.43 2.157 1 12.307 36.330 17.466 K Factor = 8.00 to 120.0 0.0 12.307 0.0 41T 156.1 0.1740 0.0 48.637 8.464 Vel = 13.71 0.0 156.10 25.930 KFactor= 30.66 12T -117.91 2.157 IT 12.307 27.500 20.569 to 120.0 0.0 12.307 0.0 S19 -117.91 -0.1036 0.0 39.807 -4.123 Vel = 10.35 S19 32.44 2.157 0.0 8.000 16.446 K Factor =8.00 to 120.0 0.0 0.0 0.0 S20 -85.47 -0.0570 0.0 8.000 -0.456 Vel = 7.50 S20 31.99 2.157 0.0 8.000 15.990 K Factor =8.00 to 120.0 0.0 0.0 0.0 S21 -53.48 -0.0240 0.0 8.000 -0.192 Vel = 4.70 S21 .31.80 2.157 0.0 8.000 15.798 K Factor =8.00 to 120.0 0.0 0.0 0.0 . S22 -21.68 -0.0045 0.0 8.000 -0.036 Vel = 1.90 S22 31.76 2.157 0.0 8.000 15.762 K Factor =8.00 to 120.0 0.0 0.0 0.0 . S23 10.08 0.0010 0.0 8.000 0.008 Vel = 0.89 S23 31.77 2.157 0.0 8.000 15.770 K Factor =8.00 to 120.0 0.0 0.0 0.0 . . ........- S24 41.85 0.0152 0.0 8.000 0.122 Vel = 3.67 S24 31.89 2.157 0.0 8.000 15.892 K Factor =8.0O to 120.0 0.0 0.0 0.0 S25 7374 0.0435 0.0 8.000 0.348 Vel = 6.47 S25 32.24 2.157 0.0 8.000 16.240 K Factor =8.00 to 120.0 0.0 0.0 0.0 S26 105.98 0.0850 0.0 8.000 0.680 Vel = 9.30 S26 32.91 2.157 0.0 8.000 16.920 K Factor =8.00 to 120.0 0.0 0.0 0.0 S27 138.89 0.1403 0.0 8.000 1.122 VeI= 12.19 S27 33.98 2.157 0.0 36.330 18.042 K Factor = 8.00 to 120.0 0.0 0.0 0.0 42T 172.87 0.2102 0.0 36.330 7.635 Vel = 15.18 . . . 0.0 172.87 25.677 KFactor= 34.12 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 .. Final. Calculations - Hazen-Williams AAA FIRE SPRINKLERS Page 11 ISIS SYSTEM PROOF CALC Date 11-30-11 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point at Pf/Ft Eqv. Ln. Total Pf Pn 13T -63.09 2.157 1 12.307 27.500 21.604 to 120.0 0.0 12.307 0.0 S28 -63.09 -0.0326 0.0 39.807 -1.297 Vel = 554 S28 36.05 2.157 0.0 8.000 20.307 K Factor =8.00 to 120.0 0.0 0.0 0.0 0 0 S29 -27.04 -0.0068 0.0 8.000 -0.054 Vel = 2.37 S29 36.00 2.157 0.0 8.000 20.253 K Factor =8.00 to 120.0 0.0 0.0 0.0 S30 8.96 0.0009 0.0 8.000 0.007 Vel = 0.79 S30 36.01 2.157 0.0 8.000 20.260 K Factor 8.00 to 120.0 0.0 0.0 0.0 S31 44.97 0.0174 0.0 8.000 0.139 Vel = 3.95 S31 36,14 2.157 0.0 8.000 20.399 K Factor =8.00 to 120.0 0.0 0.0 0.0 S32 81.11 0.0519 0.0 8.000 0.415 Vel = 7.12 S32 3649 2.157 00 68.330 20.814 K Factor =800 to . 120.0 0.0 0.0 0.0 43T 117.6 0.1031 0.0 68.330 7.042 Vel = 10.33 0.0 117.60 27.856 KFactor= 22.28 14T 69.92 2.157 2T 24.613 147.750 22.919 to 120.0 0.0 24.613 0.0 44T 69.92 0.0394 0.0 172.363 6.789 VeI= 6.14 0.0 69.92 . 29.708 K Factor = 12.83 15T -62.83 2.157 2T 24.613 147.750 37.456 to 120.0 0.0 24.613 0.0 451 -62.83 -0.0323 0.0 172.363 -5.571 Vel = .5.52 0.0 -62.83 31.885 K Factor -11.13 16T -51.62 2.157 2T 24.613 147.750 36.874 TO. to 120.0 0.0 24.613 0.0 46T -51.62 -0.0225 0.0 172.363 -3.872 Vel = 4.53 0.0 -51.62 . 33.002 K Factor = -8.99 17T -44.41 2.157 2T 24.613 147.750 36.656 to 120.0 0.0 24.613 0.0 47T -44.41 -0.0170 0.0 172.363 -2.931 Vel = 3.90 0.0 -44.41 33.725 K Factor = -7.65 181 -38.04 2.157 21 24.613 147.750 36.553 . to 120.0 0.0 24.613 0.0 ' 481 -38.04 -0.0128 0.0 172.363 -2.202 Vel = 3.34 0.0 O0O -38.04 34.351 K Factor -6.49 19T -32.26 2.157 2T 24.613 147.750 36.522 to 120.0 0.0 24.613 0.0 491 -32.26 -0.0094 0.0 172.363 -1.623 Vel = 2.83 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams AAA FIRE SPRINKLERS Page 12 ISIS SYSTEM PROOF CALC Date 11-30-11 Hyd. Qa Dia. Fitting Pipe Pt Pt -. Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn -. 0.0 -32.26 34.899 K Factor= -5.46 20T -26.76 2.157 2T 24.613 147.750 36.532 to 120.0 0.0 24.613 0.0 SOT -26.76 -0.0067 0.0 172.363 -1.148 VeI= 2.35 0.0 -26.76 35.384 K Factor = -4.50. 21T -20.14 2.104 2T 21.805 147.750 36.565 to 120.0 0.0 21.805 0.0 511 -20.14 -0.0044 0.0 169.555 -0.754 Vel = 1.86 0.0 . -20.14 35.811 K Factor = -3.37 lOT 133.12 2.104 IT 10.902 2.000 18.745 to 120.0 0.0 10.902 0.866 10 133.12 0.1463 0.0 12.902 1.888 VeI= 12.28 0.0 133.12 21.499 KFactor= 28.71 lIT 134.35 2.104 11 10.902 2.000 18.921 to 120.0 0.0 10.902 0.866 II 134.35 0.1488 0.0 12.902 1.920 VeI= 12.40 0.0 134.35 21.707 KFactor= 28.84 121 117.91 2.104 IT 10.902 2.000 20.569 to 120.0 0.0 10.902 0.866 12 117.91 0.1169 0.0 12.902 1.508 Vel = 10.88 0.0 117.91 22.943 K Factor= 24.62 13T 63.09 2.104 IT 10.902 2.000 21.604 to 120.0 0.0 10.902 0.866 13 63.09 0.0367 0.0 12.902 0.474 Vel 5.82 0.0 63.09 22.944 K Factor = 13.17 14T -69.92 2.104 iT 10.902 2.000 22.919 to 120.0 0.0 10.902 7.363 14 -69.92 -0.0445 0.0 12.902 -0.574 Vel = 6.45 0.0 -69.92 29.708 K Factor = -12.83 151 62.83 2.104 IT 10.902 2.000 37.456 to 120.0 0.0 10.902 7.363 15 . 62.83 0.0364 0.0 12.902 0.470 Vel = 5.80 0.0 62.83 45.289 K Factor = 9.34 16T 51.62 2.104 iT 10.902 2.000 36.874 to 120.0 0.0 10.902 0.866 16.. 51.62 0.0253 0.0, 12.902 0.327 Vel = 4.76 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams AAA FIRE SPRINKLERS Page 13 ISIS SYSTEM PROOF CALC Date 11-30-11 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt PfIFt Eqv. Ln. Total Pf Pn 51.62 38.067 K Factor = 8.37 -- 17T 44.41 2.104 IT 10.902 2.000 36.656 to . 120.0 0.0 10.902 0.866 17 44.41 0.0191 0.0 12.902 0.247 Vel = 4.10 0.0 44.41 37.769 K Factor = 7.23 18T 38.04 2.104 IT 10.902 2.000 36.553 to 120.0 0.0 10.902 0.866 18 38.04 0.0144 0.0 12.902 0.186 Vel = 3.51 V 0.0 38.04 37.605 K Factor = 6.20 19T 32.26 2.104 iT 10.902 2.000 36.522 to 120.0 0.0 10.902 0.866 19 32.26 0.0106 0.0 12.902 0.137 Vel = 2.98 0.0 V 32.26 37.525 K Factor= 5.27 V 20T 26.76 2.104 IT 10.902 2.000 36.532 to 120.0 0.0 10.902 0.866 V 20 26.76 0.0075 0.0 12.902 0.097 Vel = 2.47 0.0 26.76 37.495 K Factor = 4.37 21T 20.14 2.104 IT 10.902 2.000 36.565 to 120.0 0.0 10.902 7.363 21 20.14 0.0044 0.0 12.902 0.057 Vel = 1.86 0.0 V V 20.14 43.985 K Factor = 3.04 40T 156.29 2.104 IT 10.902 2.000 25.848 to 120.0 0.0 10.902 0.866 V 40 156.29 0.1969 0.0 12.902 2.540 Vel = 14.42 VVVV 0.0 156.29 29.254 K Factor= 28.90 41T 156.10 2.104 IT 10.902 2.000 25.930 to 120.0 0.0 10.902 0.866 41 V 156.1 0.1964 0.0 12.902 2.534 Vel = 14.40 V 0.0 156.10 29.330 K Factor= 28.82 421 172.87 2.104 1 10.902 2.000 25.677 to 120.0 0.0 10.902 0.866 V 42 172.87 0.2373 0.0 12.902 3.061 Vel = 15.95 0.0 V 172.87 29.604 KFactor= 31.77 43T 117.60 2.104 IT 10.902 2.000 27.856 to 120.0 0.0 10.902 0.866 V 43 117.6 0.1163 0.0 12.902 1.501 Vel = 10.85 V 0.0 117.60 30.223 KFactor= 21.39 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 a ' Final Calculations - Hazen-Williams AAA FIRE SPRINKLERS Page 14' ISIS SYSTEM PROOF CALC Date 11-30-11 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "Ct' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 44T 69.92 2.104 1 10.902 2.000 29.708 to 120.0 0.0 10.902 0.866 44 69.92 0.0445 0.0 12.902 0.574 Vel = 6.45 0.0 69.92 31.148 K Factor = 12.53 45T -62.83 2.104 IT 10.902 2.000 31.885 to 120.0 0.0 10.902 0.866 45 ' -62.83 -0.0364 0.0 12.902 -0.470 Vel = 5.80 0.0 -62.83 32.281 K Factor = -11.06 46T -51.62 2.104 IT 10.902 2.000 33.002 -- . to 120.0 0.0 10.902 0.866 46 -51.62 -0.0253 0.0 12.902 -0.327 Vel = 4.76 0.0 -51.62 33.541 KFactor= -8.91 471. -44.41 2.104 IT 10.902 2.000 33.725 to 120.0 0.0 10.902 0.866 47 -44.41 -0.0192 0.0 12.902 -0.248 Vel = 4.10 0.0 -44.41 34.343 K Factor= -7.58 48T -38.04 2.104 IT 10.902 2.000 34.351 to 120.0 0.0 10.902 0.866 48 -38.04 -0.0144 0.0 12.902 -0.186 Vel = 3.51 ' 0.0 -38.04 35.031 K Factor= -6.43 491 -32.26 2.104 IT 10.902 2.000 34.899 to 120.0 0.0 10.902 0.866 49 -32.26 -0.0106 0.0 12.902 -0.137 Vel = 2.98 0.0 -32.26 35.628 K Factor= -5.40 SOT -26.76 2.104 IT 10,902 2.000 35.384 ' to 120.0 0.0 10.902 0.866 50 , -26.76 -0.0075 0.0 12.902 -0.097 Vel = 2.47 0.0 -26.76 36.153 KFactor= -4.45 51 -20.14 2.104 IT 10.902 2.000 35.811 to 120.0 0.0 10.902 0.866 SI -20.14 -0.0044 0.0 12.902 -0.057 Vel = 1.86 0.0 -20.14 36.620 K Factor= -3.33 ' 40 156.29 4.26 0.0 12.000 29.254 to ' 120.0 0.0 0.0 0.0 ' 41 156.29 0.0063 0.0 12.000 0.076 Vel = 3.52 41 156.10 4.26 0.0 12.000 29.330 to 120.0 0.0 0.0 0.0 42 312.39 0.0228 0.0 12.000 0.274 Vel = 7.03 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Q Final Calculations - Hazen-Williams AAA FIRE SPRINKLERS Page 15 ISIS SYSTEM PROOF CALC Date 11-30-I1-. Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. loc..or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 42 172.87 4.26 0.0 12.000 29.604 to 120.0 0.0 0.0 0.0 43 485.26 0.0516 0.0 12.000 0.619 Vel = 10.92 43 117.60 4.26 0.0 12.000 30.223 to 120.0 0.0 0.0 0.0 44 602.86 0.0771 0.0 12.000 0.925 Vel = 13.57 44 69.93 4.26 0.0 12.000 31.148 to 120.0 0.0 0.0 0.0 45 672.79 0.0944 0.0 12.000 1.133 Vel = 15.14 45 -62.83 4.26 0.0 16.000 32.281 to 120.0 0.0 0.0 0.0 46 609.96 0.0788 0.0 16.000 1.260 Vel = 13.73 46 -51.62 4.26 0.0 12.000 33.541 to 120.0 0.0 0.0 0.0 47 558.34 0.0668 0.0 12.000 0.802 Vel = 12.57 47 -44.41 4.26 0.0 12.000 34.343 to . 120.0 0.0 0.0 0.0 -. 48 513.93 0.0573 0.0 12.000 0.688 VeI= 11.57 48 -38.04 4.26 0.0 12.000 35.031 to 120.0 0.0 0.0 0.0 49 475.89 0.0497 0.0 12.000 0,597 Vel = 10.71 49 -32.26 4.26 0.0 12.000 35.628 to 120.0 0.0 0.0 0.0 50 . 443.63 0.0438 0.0 12.000 0.525 Vel = 9.99 50 -26.76 4.26 0.0 12.000 36.153 to 120.0 0.0 0.0 0.0 51 416.87 . 0.0389 0.0 12.000 0.467 Vel = 9.38 .51 -20.14 4.26 1E 13.167 52.250 36.620 to . 120.0 0.0 13.167 0.0 FMI 396.73 0.0355 0.0 65.417 2.325 Vel = 8.93 FM1 654.60 4.26 1 13.167 21.000 38.945 to 120.0 0.0 13.167 0.0 'TR 1051.33 0.2156 0.0 34.167 7.366 Vel = 23.67 TR 0.0 6.357 1E 17.603 17.000 46.311 to 120.0 1 12.573 67.896 5.630 BR 1051.33 0.0307 iT 37.72 84.896 2.606 Vel = 10.63 BR 0.0 6.357 0.0 20.000 54.547 to 120.0 0.0 0.0 0.0 BF1 1051.33 0.0307 0.0 20.000 0.614 Vel = 10.63 BFI 0.0 6.16 IG 4.304 8.000 55.161 to 140.0 2E 40.168 44.472 12.788 * Fixed loss = 10.189 BF2 1051.33 0.0269 lZai 0.0 52.472 1.411 Vel = 11.32 BF2 0.0 6.09 1 4.625 20.000 69.360 to 150.0 IT 46.249 50.874 0.0 U 1051.33 0.0250 0.0 70.874 1.774 Vel = 11.58 UG 0.0 7.98 1G 6.041 94.000 71.134 to 150.0 1T 52.855 58.895 0.0 UGI 1051.33 0.0067 0.0 152.895 1.026 Vel = 6.74 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations — Hazen-Williams AAA FIRE SPRINKLERS Page 16 ISIS SYSTEM PROOF CALC Date 11-30-11 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn UGI 0.0 7.98 2G 12.081 375.000 72.160 to 150.0 IT 52.855 64.937 0.0 SRC 1051.33 0.0067 0.0 439.937 2.953 Vel = 6.74 500.00 Qa = 500.00 1551.33 75.113 K Factor = 179.00 .c .)•). Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 AutoPeaking Summary. AAA FIRE SPRINKLERS Page 17 ISIS SYSTEM PROOF CALC Date 11-30-11 Auto Peaking Summary - List of Pipes for Area Calculated Left Right Side Side From To Length From To Length S9 40T 36.330 lOT SI 3.500 SiB 41T 36.330 lIT SIO 3.500 S27 42T 36.330 12T S19 27.500 S32 43T 68.330 13T S28 27.500 Flow Safety Pressure Required Margin Differential Left Area Calculated 8.000 I 1554.212 I 1551.331 12.982 12.810 -0.172 0.000 Typical Distance Between Heads = 8.000 Split Point Used in Worst Area Peaked = S5 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087