HomeMy WebLinkAbout2628 GATEWAY RD; 125; FPC2019-0069; Permitcity of PERMIT REPORT Carlsbad Print Date: 10/15/2021 Permit No: FPC2019-0069 Job Address: 2628 GATEWAY RD, #125, CARLSBAD, CA 92009 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2132621900 Track #: Applied: 03/14/2019 Valuation: $77,664.00 Lot #: Issued: 05/14/2019 Occupancy Group: Project U: Finaled Close Out: 05/25/2021 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: Description: MANGO MANGO -SPRINKLER TI (8 HEADS) Applicant: FPContractor: UNITED FIRE SOLUTIONS INC UNITED FIRE SOLUTIONS INC STEPHEN MARTZ 41120 ELM ST, U STE G 41120 ELM ST, U G MURRIETA, CA 92562-9515 MURRIETA, CA 92562-9515 (951) 225-4666 (951) 378-0603 FEE AMOUNT FIRE NFPA 13 or 13R System 7- 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Worldwide www.tyco-fire.com Contacts Series DS Pendent, Standard -1 - 56 k-factor, Uprighthand Hoi Response, Stani Dry-type Sprinklers 'izontal Sidewall lard Coverage F General Description TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response (5 mm bulb), Standard Coverage Dry-type Sprinklers are dec- orative glass bulb automatic sprinklers typically used where: pendent sprinklers are required on dry pipe systems that are exposed to freezing temperatures (e.g., sprin- kler drops from unheated portions of buildings) sprinklers and/or a portion of the connecting piping may be exposed to freezing temperatures (e.g., sprin- kler drops from wet systems into freezers, sprinkler sprigs from wet systems into unheated attics, or hor- izontal piping extensions through a wall to protect unheated areas of a building such as loading docks, over- hangs, and building exteriors) sprinklers are used on systems that are seasonably drained to avoid freezing (e.g., vacation resort areas) FILTSTM Series DS-1 Dry-type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Series DS-1 Dry-type Sprinklers must only be installed in fittings that meet the requirements of the Design Crite- ria section. Sprinkler Identification Numbers (SINs) tIIU Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connections 1 inch NPT ISO 7-R 1 1Y3255 - Pendent 1Y3155 - Upright Discharge Coefficient 1Y3355 - Horizontal Sidewall K=5.6 gpm/ps1112 (80,6 pm/ban/2) IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 Technical Data Approvals UL and C-UL Listed FM Approved VdS Approved TY3255 w/Standard Escutcheon only NYC Approved under MEA 352-01-E LPCB Approved Reference No. 094a/11 CE Certified Certificate of Conformity No. 0832- CPD-201 5 (Refer to Tables A and B for details.) AUGUST 2018 Temperature Ratings Refer to Tables A and B. Finishes Sprinkler: Refer to Table D. Escutcheon: Refer to Table D. Physical Characteristics Inlet .............................Copper Plug .............................Copper Yoke.......................Stainless Steel Casing .............Galvanized Carbon Steel Insert .............................Bronze Bulb Seat...................Stainless Steel Bulb (5 mm dia.) .....................Glass Compression Screw .................Bronze Deflector ..........................Bronze Frame ............................Bronze Guide Tube .................Stainless Steel Water Tube .................Stainless Steel Spring .....................Stainless Steel Sealing Assembly. Beryllium Nickel wfTEFLON Escutcheon ...................Carbon Steel TFP500 TFP500 Page 2 of 10 SPRINKLER TYPE ESCUTCHEON TYPE TEMPERATURE RATING BULB COLOR CODE SPRINKLER FINISH NATURAL CHROME BRASS PL ATED POLYESTER* PENDENT (TY3255) STANDARD 135°F (57°C) Orange 1, 2, 3, 4, 5, 6 1, 2, 4, 5, 6 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286-F (141-C) Blue 360°F (182°C) Mauve 1, 2, 3, 6 1, 2, 6 RECESSED 135°F (57°C) Orange 12,3,5 12,5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286-F (141-C) Blue 1,2 360°F (182°C) Mauve N/A DEEP 135°F (57°C) Orange 1, 2, 3, 4, 5 1, 2,4, 5 155°F(68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve WITHOUT 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286-F (141-C) Blue 360°F(182°C) Mauve 1,2,3 1,2 UPRIGHT (1Y3155) WITHOUT 135°F (57°C) Orange 1,2,3,4,5 1,2,4,5 155°F (68°C) Red 175-F (79-C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 1, 2:3 1,2 Notes: Listed by Underwriters Laboratories, Inc. (UL), maximum order length of 48 inches Listed by underwriters Laboratories for use in Canada (C-UL), maximum order length of 48 inches Approved by FM Global (FM Approvals), maximum order length of 48 inches Loss Prevention Certification Board (LPCB) and CE conformity apply to these temperature ratings only Approved by the City of New York under MEA 352-01-B Approved by vdS Frame and deflector only N/A - Not Applicable TABLE A SERIES DS-1 PENDENT & UPRIGHT DRY-TYPE SPRINKLERS, 5.6K, STANDARD RESPONSE LABORATORY LISTINGS AND APPROVALS TFP500 Page 3 of 10 SPRINKLER ESCUTCHEON TEMPERATURE BULB SPRINKLER FINISH NATURAL CHROME BRASS PLATED POLYESTER*** TYPE TYPE RATING COLOR CODE 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow STANDARD 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 135°F (57°C) Orange 155°F(68°C) Red 175°F (79°C) Yellow Hsw* (TY3355) DEEP 1—,2-',3--,4,5 1",2",4,5 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow WITHOUT 200°F (93°C) Green 286°F (141°C) Blue 360°F(182°C) Mauve 1",2'-,5 Notes: Listed by underwriters Laboratories, Inc. (UL), maximum order length of 48 inches Listed by Underwriters Laboratories for use in Canada (C-UL), maximum order length of 48 inches Approved by FM Global (FM Approvals), maximum order length of 48 inches Loss Prevention Certification Board (LPCB) and CE conformity apply to these temperature ratings only Approved by the City of New York under MBA 352-01-E Horizontal sidewall with top of deflector-to-ceiling distance of 4 to 12 inches (10010300 mm( Light and ordinary hazard occupancies only Light hazard occupancies only .... Frame and deflector only TABLE B SERIES DS-1 HORIZONTAL SIDEWALL (HSW) DRY-TYPE SPRINKLER, 5.6K, STANDARD RESPONSE LABORATORY LISTINGS AND APPROVALS PLUG WITH INLET SEALING ASSEMBLY YOKE SPRING INLET BAND WATER II II TUBE CASING GUIDE - INSERT TUBE NN BULB FRAME j SEAT 5 mm BULB VENT HOLE COMPRESSION DEFLECTOR SCREW FIGURE 1 SERIES DS-1 DRY-TYPE SPRINKLER, 5.6K, STANDARD RESPONSE ASSEMBLY - WRENCH RECESS WRENCH I FLAT a PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 7 WRENCH TFP500 Page 4 of 10 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 2-3/4 to 48' 1-3/4 DIA. (69,9 to 1219,2 mm) (44,5 mm) IN 1/4 (6,4 mm) INCREMENTS II I FACE OFIZZZI CEILING T . DIA. 2-3/16±1/8' (76,2 mm) (55,6 ± 3,2 mm) ___________ FIGURE 3 PENDENT (TY3255) WITH STANDARD ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING - ORDER LENGTHS: 3-3/4" to 48" (95,3 to 1219,2 mm) IN 1/4" (6,4 mm) 2-1/4 DIA. INCREMENTS (57,2 mm) FACE OF CEILING I WI 13/81 FIGURE 4 PENDENT (TY3255) WITH STANDARD RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER \ FITTING ORDER LENGTHS: 3-1/2" DIA. 1/2" to 46" (88,9 mm) (12,7 to 1168,4 mm) I IN 1/4" (6,4 mm) 21/2" DIA INCREMENTS (63,5 mm) FACE OF CEILING 4-1/4" ± 1/8' (108,0 ±j32 mm) FIGURE 5 PENDENT (TY3255) WITH DEEP ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM 1-3/4(44,5mm) DEFLECTOR TO CEILING FIGURE 6 PENDENT (TY3255) WITHOUT ESCUTCHEON TOP OF DEFLECTOR ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 7 UPRIGHT (TY3 155) WITHOUT ESCUTCHEON ORDER LENGTHS: 2-3/4" to 48" (69,9 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS 2-3/8" ± 1/8 - - (60,3 ± 3,2 mm) FACE OF FACE OF - SPRINKLER MOUNTING FITTING SURFACE 3" DIA. -3/4DIA./ (76,2 mm) SPRINKLER FITTING (REFER TO DESIGN (44,5 mm) CENTERLINE 5/16 CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 8 HORIZONTAL SIDEWALL (TY3355) WITH STANDARD ESCUTCHEON ORDER LENGTHS: 1/2"t045-3/4"(12,7t01162,1 mm) IN 1/4" (6,4 mm) INCREMENTS 2-1/2" DIA. FACE OF (63,5 mm) SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) 4-1/4" ± 1/8" FACE OF - (108,0 ± 3,2 mm) MOUNTING SURFACE _ I r3.5- 3-1/2" DIA. (88,9 mm) CENTERLINE 5/16" OF WATERWAY (7,9 mm) FIGURE 9 HORIZONTAL SIDEWALL (TY3355) WITH DEEP ESCUTCHEON ORDER LENGTHS: I 5-1/2' to 48" (139,7 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF - SPRINKLER FITTING MINIMUM 2-1/4" (57,2 mm) DEFLECTOR TO MOUNTING SURFACE SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) / 3o I 5/16' / (7,9 mm) CENTERLINE OF WATERWAY FIGURE 10 HORIZONTAL SIDEWALL (TY3355) WITHOUT ESCUTCHEON TFP500 Page 5 of 10 Operation When TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response, Standard Coverage Dry-type Sprinklers are in service, water is prevented from entering the assembly by the Plug with Sealing Assembly (Ref. Figure 1) in the Inlet of the sprinkler. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, and the Bulb Seat is released. The compressed Spring is then able to expand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with Sealing Assembly from the Inlet, allow- ing the sprinkler to activate and flow water. Design Criteria TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response, Standard Coverage Dry-type Sprinklers are intended for use in fire sprinkler systems designed in accordance with the standard instal- lation rules recognized by the applica- ble listing or approval agency (e.g., UL Listing is based on NFPA 13 require- ments). For more information on LPCB Approval, contact Johnson Controls at the following office: Kopersteden 1 7547 TJ Enschede The Netherlands Tel: +31-(0)53-428-4444 Fax: +31-(0)53-428-3377 Sprinkler Fittings Install 1 in. NPT Series DS-1 Dry-type Sprinklers in the 1 in. NPT outlet or run of the following fittings: malleable or ductile iron threaded tee fittings that meet the dimen- sional requirements of ANSI B16.3 (Class 150) cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125) Do not install Series DS-1 Dry-type Sprinklers into elbow fittings. The Inlet of the sprinkler can contact the interior of the elbow. The unused outlet of the threaded tee is plugged as shown in Figure 12. TFP500 Page 6 of 10 Temperatures for Heated Area(1) Ambient Temperature 40°F I 50°F 60°F Exposed to (4°C) (10°C) (16°C) Minimum Exposed Barrel Length(2), Discharge End of Sprinkler Inches (mm) 40°F (4°C) 0 0 0 30°F (-1°C) 0 0 0 20°F 4 0 0 (-7°C) (100) 10°F 8 1 0 (-12°C) (200) (25) 0°F 12 3 0 (-18°C) (305) (75) -10°F 14 4 1 (-23°C) (355) (100) (25) '-20°F 14 6 3 (-29°C) (355) (150) (75) -30°F 16 8 4 (-34°C) (405) (200) (100) -40°F 18 8 4 (-40°C) (455) (200) (100) -50°F 20 10 6 (-46°C) (510) (255) (150) -60°F 20 10 6 (-51°C) (510) (255) (150) Notes: For protected area temperatures that occur between values listed above, use the next cooler temperature. These lengths are inclusive of wind velocities up to 30 mph (18,6 kph). TABLE C EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS MINIMUM RECOMMENDED LENGTHS You can also install Series DS-1 Dry- type Sprinklers in the 1 inch NPT outlet of a GRINNELL Figure 730 Mechanical Tee and GRIN NELL G-FIRE Figure 522; however, the use of the Figure 730 Tee and Figure 522 for this arrangement is limited to wet pipe systems. The configuration shown in Figure 13 is only applicable for wet pipe systems where the sprinkler fitting and water- filled pipe above the sprinkler fitting are not subject to freezing and where the length of the dry-type sprinkler has the minimum exposure length depicted in Figure 11. Refer to the Exposure Length section. For wet pipe system installations of 1 inch NPT Series DS-1 Dry-Type Sprin- klers connected to CPVC piping, use only the following TYCO CPVC fittings: 1 in. x 1 in. NPT Female Adapter (P/N 80145) 1 in. x 1 in. x 1 in. NPT Sprinkler Head Adapter Tee (P/N 80249) For dry pipe system installations, use only the side outlet of maximum 2-1/2 inch reducing tee when locating Series DS-1 Dry-type Sprinklers directly below the branchline; otherwise, use the configuration shown in Figure 12 to assure complete water drainage from above Series DS-1 Dry-type Sprin- klers and the branchline. Failure to do so may result in pipe freezing and water damage. NOTICE Do not install Series DS-1 Dry-type Sprinklers into any other type fitting without first consulting the Johnson Controls. Technical Services. Failure to use the appropriate fitting may result in one of the following: failure of the sprinkler to operate properly due to formation of ice over the Inlet Plug or binding of the Inlet Plug insufficient engagement of the Inlet pipe-threads with consequent leakage Drainage In accordance with the minimum requirements of the NATIONAL FIRE PROTECTION ASSOCIATION for dry pipe sprinkler systems, branch, cross, and feed-main piping connected to Dry Sprinklers and subject to freezing tem- peratures must be pitched for proper drainage. Exposure Length When using Dry Sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use Table C to determine a sprinkler's appropriate exposed barrel length to prevent water from freezing in the con- necting pipes due to conduction. The exposed barrel length measurement must be taken from the face of the sprinkler fitting to the surface of the structure or insulation that is exposed to the heated area. Refer to Figure 11 for an example. For protected area temperatures between those given above, the minimum recommended length from the face of the fitting to the outside of the protected area may be determined by interpolating between the indicated values. Clearance Space In accordance with NFPA 13, when connecting an area subject to freez- ing and an area containing a wet pipe sprinkler system, the clearance space around the sprinkler barrel of dry-type sprinklers must be sealed. Due to tem- perature differences between two areas, the potential for the formation of condensation in the sprinkler and subsequent ice build-up is increased. If this condensation is not controlled, ice build-up can occur that might damage the dry-type sprinkler and/or prevent proper operation in a fire situation. Use of the Model DSB-2 Dry Sprinkler Boot, described in technical data sheet TFP591 and shown in Figures 14 and 15, can provide the recommended seal. TFP500 Page 7 of 10 FACE OF SPRINKLER - - FITTING I EXPOSURE _________ • LENGTH (SEE DESIGN DSB-2 CRITERIA INTENDED SECTION) FOR FREEZER STRUCTURES FIGURE 11 EXPOSURE LENGTH QIL RUN OUTLET PLUGGED SPRINKLER FITTING TO DRY (SEE-DESIGN SYSTEM CRITERIA SECTION) DSB-2 INTENDED FOR FREEZER 4 STRUCTURES FIGURE 12 SPRINKLER FITTING UNHEATED AREA TO WET SIDE SYSTEM OUTLET ri P5UGGED Icon DSB-2 SPRINKLER INTENDED FITTING FOR FREEZER (SEE DESIGN STRUCTURES CRITERIA SECTION) FIGURE 13 SPRINKLER FITTING HEATED AREA STRAP TIES (ENDS ON -OPPOSING SIDES OF BOOT) DSB-2 BOOT 1-3/4 DIA. (44,5 mm) CLEARANCE HOLE INSULATED -FREEZER STRUCTURE DS-1 SHOWN WITH STANDARD ESCUTCHEON FIGURE 14 MODEL DSB-2 DRY SPRINKLER BOOT WITH PENDENT SERIES DS-1 DRY-TYPE SPRINKLER 1-3/4 DIA. (44,5 mm) CLEARANCE INSULATED HOLE FREEZER ADHESIVE STRUCTURE BOOT STRAP TIES DS-1 (ENDS ON SHOWN WITH OPPOSING STANDARD SIDES OF ESCUTCHEON BOOT) FIGURE 15 MODEL DSB-2 DRY SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY-TYPE SPRINKLER TFP500 Page 8 of 10 Installation TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response, Standard Coverage Dry-type Sprinklers must be installed in accordance with this section. General Instructions Series DS-1 Dry-type Sprinklers must only be installed in fittings that meet the requirements of the Design Crite- ria section. Refer to the Design Criteria section for other important require- ments regarding piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) rating to 1/8 inch (3,2 mm) for the 360°F (182°C) rating. Obtain a leak-tight 1 inch NPT sprinkler joint by applying a minimum-to-maxi- mum torque of 20 to 30 lb-ft (26,8 to 40,2 Nm). Higher levels of torque may distort the sprinkler Inlet with conse- quent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under or over-tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Notes: Install pendent sprinklers only in the pendent position; install upright sprinklers only in the upright posi- tion. The deflector of a pendent or upright sprinkler is to be parallel to the ceiling. Install horizontal sidewall sprinklers in the horizontal position with their centerline of waterway perpendicu- lar to the back wall and parallel to the ceiling. Ensure the word "TOP" on the Deflector faces the ceiling. Step 1. With a non-hardening pipe- thread sealant such as TEFLON applied to the inlet threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Wrench-tighten the sprinkler using either: a pipe wrench on the Inlet Band or the Casing (Ref. Figure 1) the W-Type 7 Sprinkler Wrench on the Wrench Flat (Ref. Figure 2) Apply the wrench recess of the W-Type 7 Sprinkler Wrench to the wrench flat. Note: If sprinkler removal becomes necessary, remove the sprinkler using the same wrenching method noted above. Sprinkler removal is easier when a non-hardening sealant was used and torque guidelines were followed. After removal, inspect the sprinkler for damage. Step 3. After installing the ceiling or wall and applying a ceiling finish, slide on the outer piece of the escutch- eon until it comes in contact with the ceiling/wall. Do not lift the ceiling panel out of its normal position. When using the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling or wall). Then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Standard Response, Standard Cover- age Dry-type Sprinklers must be main- tained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. A Vent Hole is provided in the Bulb Seat (Ref. Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evidence of leakage from the Vent Hole indicates potential leakage past the Inlet seal and the need to remove the sprinkler to determine the cause of leakage; for example, an improper installation or an ice plug. Close the fire protec- tion system control valve and drain the system before removing the sprinkler. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installa- tion section). The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSO- CIATION (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. SPRINKLER FINISH CHROME 0 PLATED NATURAL 1 BRASS ESCUTCHEON FIN 1514(11 SIGNAL WHITE (RAL9003) POLYESTER SIGNAL WHITE (RAL9003) POLYESTER 2 I NATURAL I BRASS I BRASS PLATED SIGNAL WHITE SIGNAL WHITE 4 (RAL9003) (RAL9003) POLYESTER POLYESTER CHROME CHROME PLATED PLATED I _L TEMPERATURE RATING(2) 0 135-F (57-C) 1 155-F (68-C). 2 175°F(79°C) 3 200°F(93°C) 4 286-F (141-C) 5 1 360°F(182°C) ORDER LENGTH(3) 055 5.50 in. 082 8.25 in. 180 18.00 in. 187 18.75 in. 372 37.25 in. 480 48.00 in. TFP500 Page 9 of 10 PIN* 60 -. XXX - X - XXX SIN 96 Pendent with TY3255 Standard Escutcheon (1 in. NPT) (Figure 3) 93 Pendent with TY3255 Deep Escutcheon (1 in. NPT) (Figure 5) 97 Pendent with TY3255 Recessed Escutcheon (1 in. NPT) (Figure 4) 92 Pendent without 1Y3255 Escutcheon (1 in. NPT) (Figure 6) Sidewall with TY3355 94 Standard Escutcheon (1 in. NPT) (Figure 8) 53 Sidewall with 1Y3355 Deep Escutcheon (1 in. NPT) (Figure 9) 54 Sidewall without TY3355 Escutcheon (1 in. NPT) (Figure 10) Upright without I TY3155 I I Escutcheon (1 in. NPT) I (Figure 7) I Notes: Escutcheon Finish applies to sprinklers provided with escutcheons. 360'F 1182"Cl temperature rating applies to non-recessed sprinkler assemblies. Dry-type Sprinklers are furnished based upon "Order Length" as mea- sured per Figures 3 through tO, as applicable, and for each individual sprinkler where it is to be installed. After the measurement is taken, round it 10 the nearest 1/4 inch increment. Use Prefix I" for ISO 7-R 1 Connection (eg., 1-60-961-1-180). TABLED SERIES DS-1 DRY-TYPE SPRINKLERS, 5.6K, STANDARD RESPONSE PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indi- cate the full product name, including description and part number (P/N). Dry-type Sprinklers When ordering Series DS-1 5.6K Pendent, Upright, and Horizontal Side- wall, Standard Response, Standard Coverage Dry-type Sprinklers, specify the following information: SIN: TY3255 - Pendent TY3155 - Upright TY3355 - Horizontal Sidewall Order Length: Dry-type Sprinklers are furnished based upon Order Length as mea- sured per Figures 3 through 10, as applicable. After the measurement is taken, round it to the nearest 1/4 inch increment. Inlet Connections: 1 Inch NPT (Standard) ISO 7-R 1 (For information on ISO Inlet Thread Connections, contact your Johnson Controls Sales Representative.) Temperature Rating Sprinkler Finish Escutcheon Type and Finish, as applicable P/N from Table Part numbers are for 1 inch NPT standard order sprinklers. Orders for all other sprinkler assemblies must be accompanied by a complete description. Sprinkler Wrench Specify W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Sprinkler Boot Specify Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002 This part number includes one (1) Boot, two (2) Strap Ties, and 1/3 oz. of Adhe- sive (a sufficient quantity for installing one boot). TFP500 Page 10 of 10 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 C 2018 Johnson Controls. All rightsrusorvod. All specifications and other information shown were currant as of document revision date and are subject to Change without notice. Johnson '1 NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are IegiOIered trademarks at National El,, P,nlevtlnndanacwlinn: Controls TEFLON isa,ngiolornd IrtdnnraA or DuPOnt tqcu Worldwide I Contacts I www.tyco-fire.com Series TYFRB - 28,42,5,6, and 8,0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers described in herein are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers. They are designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls. The TY-FRB Recessed Pendent Sprin- kler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following Recessed Escutcheons: A two-piece Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) Recessed Escutcheon with 1/2 in. (12,7 mm) of recessed adjustment or up to 3/4 in. (19,1 mm) of total adjustment from the flush pendent position. A two-piece Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) Recessed Escutcheon with 1/4 in. (6,4 mm) of recessed adjustment or up to 1/2 in. (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond what would be obtained when exposed IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 to corrosive atmospheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the applicable approval agen- cies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corrosive environment. The effects of ambient temperature, con- centration of chemicals, and gas/ chemical velocity, should be consid- ered, as a minimum, along with the cor- rosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356. Sprinkler Guards are detailed in Technical Data Sheet TFP780. The Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. NFPA 13 prohibits installation of 1/2 in. NPT sprinklers with K-factors greater than 5.6 in new construction. They are intended for retrofit in existing sprinkler systems only. JULY 2018 Sprinkler Identification Number (SIN) TY1131 . . . Upright 2.8K, 1/2 in. NPT TY1231.. Pendent 2.8K, 1/2 in. NPT 1Y2131 . . . Upright 4.2K, 1/2 in. NPT 1Y2231.. Pendent 4.2K, 1/2 in. NPT TY3131 . . . Upright 5.6K, 1/2 in. NPT 1Y3231.. Pendent 5.6K, 1/2 in. NPT 1Y4131 . . . Upright 8.0K, 3/4 in. NPT TY4231.. Pendent 8.0K, 3/4 in. NPT TY4831 . . . Upright 8.0K, 1/2 in. NPT 1Y4931.. Pendent 8.0K, 1/2 in. NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion-resistant status. Maximum Working Pressure Refer to Table C TFPI7I H- 2-7/8" (73,0 mm) DIA. -H RECESSED PENDENT CROSS SECTION TFPI7I Page 2 of 10 * Temperature rating ** Pipe thread connections per 1 - Frame is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Deflector. special request. PLATE SEATING SURFACE 7/16 (11,1 mm) NOMINAL 2-1/4 16" MAKE-IN (57,2 mm) 2-3/ I (55,6 mm) 1-9/16 Lq_~ 1 (39,7 mm) I 1/2 NPT** t WRENCH STYLE 10or20 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON 3 - Sealing 5 - Compression Assembly Screw 4 - Bulb 6 - Deflector* 7 - Bushing '•a CROSS SECTION 2-7/8" (73,0mm) DIA. RECESSED PENDENT FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY113I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 IN. NPT * Temperature rating ** Pipe thread connections per 1 - Frame is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Deflector, special request. PLATE SEATING SURFACE IMAKE-IN 7/16" ,1 mm)(11 2-3/16" NOMINAL (55,6mm) (55,6 mm) 1/2" NPT** I WRENCH STYLE 10 or 20 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON 3 - Sealing 5 - Compression Assembly Screw 4 - Bulb 6 - Deflector* FIGURE 2 QUICK RESPONSE SERIES TV-FRB UPRIGHT (TV2 131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 IN. NPT Discharge Coefficient K=2.8 GPM/p5i½ (40,3 LPM/bar½) K=4.2 GPM/p5i½ (60,5 LPM/bar½) K=5.6 GPM/p5i½ (80,6 LPM/bar) K=8.0 GPM/p5i½ (115,2 LPM/bar½) Temperature Rating Refer to Table A and B Finishes Sprinkler: Refer to Table D Recessed Escutcheon: Signal or Pure White, Grey Aluminum, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly. Beryllium Nickel w/TEFLON Bulb...............................Glass Compression Screw .................Bronze Deflector ...................Copper/Bronze Bushing (K=2.8) ....................Bronze Poly-Stainless Physical Characteristics Frame ............................Bronze Button ................L316 Stainless Steel Bulb ............................. .. Glass Compression Screw .....L316 Stainless Steel Deflector ...................Copper/Bronze Sealing Assembly. Gold Plated Beryllium Nickel w/TEFLON 'Type L316 stainless steel lUNS 316031 per ASTM A479/479M or BS EN 1008 WN1.4404. Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers are intended for fire protection systems designed in accordance with the stan- dard installation rules recognized by the applicable Listing or Approval agency, such as UL Listing based on the requirements of NFPA 13 and FM Approval based on the requirements of the FM Global Loss Prevention Data Sheets. Use only the style 10, 20, 30, or 40 Recessed Escutcheon, as applica- ble, for recessed pendent installations. I I ! 2-7/8" (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION TFPI7I Page 3 of 10 * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector. special request. 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* ESCUTCHEON PLATE SEATING SURFACE I N 7/16 _______ ______(11,1 mm) OMINAL I MAK 2-3/16 (55,6 mm) 1-1/2' E-lN I 2-3/16" (38,1 mm) (55,6 mm) 1/2" NPT** I WRENCH STYLE 10 or 20 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON CROSS SECTION 2-7/8" (73,0 mm) DIA. RECESSED PENDENT ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 1/2" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated SURFACE 4 - Bulb 6 - Deflector * on Deflector. (11 1 mm) NOMINAL I (55,6 mm) 11.11/2 I 7/16" 2-3/16" MAKE-IN (55,6 mm) 2-3/16' STYLE 10 RECESSED UPRIGHT PENDENT ESCUTCHEON POLY-STAINLESS FINISH ONLY FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 IN. NPT Installation The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) and 3/32 in. (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 Nm). A leak tight 3/4 in. NPT sprinkler joint should be obtained with a torque of 10 to 20 lb-ft (13,4 to 26,8 N.m). Higher levels of torque can distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to com- pensate for insufficient adjustment in the escutcheon plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series TY-FRB Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions: Step 1. Install pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1 to Figure 5, apply the W-Type 6 Sprinkler Wrench to the sprinkler wrench flats. Series TY-FRB Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1 t 4, apply the W-Type 7 Recessed Sprin- kler Wrench to the sprinkler wrench flats. Step 3. After the ceiling is installed or the finish coat is applied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Recessed Pendent Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. 2-7/8" (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION TFPI7I Page 4 of 10 * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 Bulb 6 - Deflector* SURFACE NNOMINAL 1/2 (12,7 mm)t 2-5/16 FY _____ (58,7 mm) MAKE-IN 2-1/4 1-9/16" I Wo1__r___, mrn,/i (39,7 mm) I t (57,2 3/4" NPT I WRENCH STYLE 30 or 40 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 3/4" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated SURFACE 4 - Bulb 6 - Deflector* on Deflector. 2-7/8" (73,0 mm) DIA. UPRIGHT 1/2" (12,7 mm) MAKE-IN (58,7 mm) NOMINAL 2-5/16" (57,2 mm) STYLE 40 RECESSED PENDENT ESCUTCHEON POLY-STAINLESS FINISH ONLY FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 IN. NPT CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw Assembly 4 - Bulb 7/16" (11,1 mm) (57,2 mm) _________ / 3 - Sealing 6 - Deflector * MAKE-IN indicated on Deflector. m 1-9/16" I 23/16 NOMINAL * Temperature rating is ** Pipe thread connections (39,7 mm) (55,6m) per 1507-1 can be provided on special 6 * 1/2 NPT** I WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 112 IN. NPT TFPI7I Page 5 of 10 - 27/8" DIA. 5/8±1/4 (73,0 mm) 3/4° (19,1 mm) (15,9±6,4 mm) / I i/4' (6,4 mm) I FACE OF - 2-1/4 DIA. (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8' (3,2 mm) $11 MOUNTING / SURFACE/' CLOSURE SERIES 1-5/16' (333 mm)j TYFRB 13/16" (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 IN. NPT 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. J 1/4" (6,4 mm) / FACE OF - (57,2 mm) MOUNTING SPRINKLER PLATE _1 FITTING 1/8" / (3,2 mm) -_____ MOUNTING SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE TY-FRB 3/4' (19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 IN. NPT - 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2(12,7mm) (12,7±3,2 mm) 2-1/4" DIA. I 1/4" (6,4 mm) I / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) 71. MOUNTING $ $ \ /k J SURFACE CLOSURE SERIES TY-FRB 1-1/16" (27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 IN. NPT 2-7/8" DIA. - -. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4° (6,4 mm) / FACE OF I (57,2 mm) MOUNTING PLATE I SPRINKLER -'\ .1 I FITTING I 1/8' I LI (3,2 mm I MOUNTING / 1 SURFACE / SERIES 1-1 (31,8mm) CLOSURE /4" TY-FRB 1" (25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 IN. NPT TFPI7I Page 6 of 10 2-7/8 DIA. - 5/8±1/4" (73,0 mm) I 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4' DIA. 1/4" (6,4 mm) I PLATE I SPRINKLER FITTING 1/8' / FACE OF (57,2 mm) MOUNTING (3,2 mm) \4 MOUNTING SURFACE SERIES 1-1/4' (31,8 mm) CLOSURE TY-FRB 3/4" (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT 2-7/8" 01k (73,0 mm) 3/4" (19,1 mm) 2-1/4" DIA. 1/4" (6,4 mm) I (57,2 mm) MOUNTING PLATE I 1/8" I (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/1;(33,3 mm)1 TY-FRB 13/16" (20,6 mm) FIGURE 12 SERIES TV-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 IN. NPT WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH - 2-7/8" DIA. (73,0 mm) 1/2±1/8" 1/2k (12,7 mm) / FACE OF 2 mm) (12 7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57, MOUNTING ''?- - I SPRINKLER PLATE I FITTING 1/8" / Lq (3,2 mm) J . MOUNTING SURFACE SERIES 1-1/4(31,8mm) - CLOSURE TY-FRB 1" (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA 1/4" (6,4 mm) / FACE OF - (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) , MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm)1 TY-FRB 1-1/16" (27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 IN. NPT WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING TFPI7I Page 7 of 10 Sprinkler Finish5 K- Type Temperature Bulb Bulb Liquid Color Natural Brass Chrome Plated PolyesterC Pendent (TY1231) and Upright (TY1131) 135°F (57°C) Orange 1, 2, 3, 4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 2.8 1/2 in. NPT Recessed Pendent (TY1231)a Figure 6 135°F (57°C) Orange 1,2,4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green Recessed Pendent (TY1231)b Figure 7 135°F(57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 4.2 1/2 in. NPT Pendent (1Y2231) and Upright (TY2131) 135°F (57°C) Orange 1,2 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Recessed Pendent (TY2231)a Figure 8 135°F(57°C) Orange 155°F (68°C) . Red 175°F (79°C) Yellow 200°F (93°C) Green Recessed Pendent (TY2231)b Figure 9 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green NOTES Installed with Style 10(1/2 in. NPT) or Style 40 13/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2 in. NPT) or Style 30(3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. Where Polyester Coated Sprinklers are noted lobe UL and C-UL Listed, the sprinklers are UL and C-UL Listed, the sprinklers are UL and C-UL Listed as corrosion- resistant sprinklers. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFPI7I Page 8 of 10 Sprinkler. Fin ish8 K- Factor Type Temperature Bulb Liquid Color Natural Brass I Chrome Plated Polyester° PolyStainlessc Lead Coated Pendent (TY3231) 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow . and 1, 2, 3, 4, 5, 6, 7 1,2 1, 2, 3, 5 Upright (1Y3131) Blue 200°F (93°C) Green 286°F (141°C) 135°F (57°C) Orange 155°F (68°C) Red 5.6 1/din NPT Recessed Pendent (TY3231)a Figure 10 1, 2, 4, 5 1,2 N/Ad 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 135°F(57°C) Orange 155°F (68°C) Red Recessed Pendent (TY3231)b 1, 2, 3, 4, 5 N/A N/A 175°F (79°C) Yellow 200°F (93°C) Green Figure 11 286°F (141°C) Blue Pendent (TY4231) 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow and 1,2,3,4, 5, 6, 7 1,2 1,2,5 Upright (1Y4131) Blue 200°F (93°C) Green 286-F (141-C) 135°F (57°C) Orange 155°F (68°C) Red 8.0 3 /4 in NPT Recessed Pendent (1Y4231)a Figure 12 1,2, 5 1,2 N/A 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange 155°F (68°C) Red Recessed Pendent (TY4231)b 1, 2, 3, 5 N/A N/A 175°F (79°C) Yellow 200°F (93°C) Green Figure 13 286°F (141°C) Blue 8.0 Pendent (TY4931) 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 1/2 in. and 1, 2, 4, 5, 6 N/A 1, 2, 5 NPT Upright (TY4831) Blue 200°F (93°C) Green 286°F (141°C) NOTES Installed with Style 10(1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20(1/2 in. NPT) or Style 30 (3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Not Available (N/A) Listed by underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04( as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coaled and Lead-Coaled Sprinklers are noted lobe UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 9 of 10 Sprinkler Finish K- Factor Type Natural Brass I Chrome Plated .1 I Polyester Lead Coated Pendent (TY1231) and 2.8 Upright (TY1131) 1/2 in. 175 psi (12,1 bar) N/A2 NPT Recessed Pendent (TV1231) Pendent (TY2231) and 4.2 Upright (TY2131) 1/2 in. 175 psi (12,1 bar) N/A Recessed NPT Pendent (TY2231) Pendent (TY3231) and 5.6 Upright (TY3131) 250 psi (17,2 bar) 1/2 in. or 175 psi (12,1 bar)' Recessed NPT Pendent (TY3231) Pendent (TY4231) 175 psi 8.0 and Upright (TY4131) (12,1 bar) 3/4 in. 175 psi (12,1 bar) Recessed N/A NPT Pendent(TY4231) 8.0 Pendent (TY4931) 175 psi 1/2 in. and 175 psi (12,1 bar) (12,1 bar) NPT Upright (TY4831) NOTES The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Under- writers Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. Not applicable (N/A). Care and Maintenance The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire pro- tection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to TABLE C MAXIMUM WORKING PRESSURE corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be taken to avoid damage to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or sprinkler manufac- turer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section). Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice.lnspections of corrosion-resis- tant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprinkler condition and the long-term integrity of the corrosion-resistant material, which can be affected by the corrosive conditions present. TFPI7I Page 10 of 10 P/N 57— XXX - X - XXX SIN ] - SPRINKLER FINISH 1 NATURAL BRASS - POLY-STAINLESS GREY 2 ALUMINUM (RAL9007)1 - POLYESTER PURE WHITE - POLYESTER (RAL9010)2 SIGNAL WHITE - POLYESTER (RAL9003) JET BLACK - POLYESTER (RAL9005)3 7 LEAD COATED 330 2.8K UPRIGHT (1/2 in. NPT) TY1131 331 2.8K PENDENT (1/2 in. NPT) TY1231 340 4.2K UPRIGHT (1/2 in. NPT) TY2131 341 4.2K PENDENT (1/2 in. NPT) TY2231 370 5.6K UPRIGHT (1/2 in. NPT) TY3131 371 5.6K PENDENT (1/2 in. NPT) TY3231 390 8.0K UPRIGHT (3/4 in. NPT) TY4131 391 8.0K PENDENT (3/4 in. NPT) TY4231 360 8.0K UPRIGHT (1/2 in. NPT) 1Y4831 361 8.0K PENDENT (1/2 in. NPT) TY4931 TEMPERATURE RATINGS 135 135-F (57-C) 155 1 155°F(68°C) 175 175°F(79°C) 200 200°F (93°C) 286 I 286-F (141-C) 9 I CHROME PLATED NOTES Available only on TY3131, TV3231, TV4131, and TY4231 Eastern Hemisphere sales Only. Available in only 2.8K. 4.2K, and 8.0K. 155°F (68°C) and 200°F (93°C); requires longer lead time to manufacture. TABLE D SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright) Sprinkler (specify) temperature rating, (specify) finish or coating, P/N (specify from Table D) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 C 2018 Johnson Controls. All rights reserved. All specific olions and other information Shown were current as 01 document revision dots and are subject to change without notice. Johnson NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are rrglsl,rnu I,odomorkn 11 National Fire Plotnulion As,00loliolr: Controls TEFLON no roninln,nd Iredneadl OIOAPONI