HomeMy WebLinkAbout2628 GATEWAY RD; 125; FPC2019-0069; Permitcity of
PERMIT REPORT Carlsbad
Print Date: 10/15/2021 Permit No: FPC2019-0069
Job Address: 2628 GATEWAY RD, #125, CARLSBAD, CA 92009 Status: Closed - Finaled
Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers
Parcel #: 2132621900 Track #: Applied: 03/14/2019
Valuation: $77,664.00 Lot #: Issued: 05/14/2019
Occupancy Group: Project U: Finaled Close Out: 05/25/2021
#of Dwelling Units: Plan U:
Bedrooms: Construction Type:
Bathrooms: Orig. Plan Check U: Inspector:
Plan Check U: Final Inspection:
Project Title:
Description: MANGO MANGO -SPRINKLER TI (8 HEADS)
Applicant: FPContractor:
UNITED FIRE SOLUTIONS INC UNITED FIRE SOLUTIONS INC
STEPHEN MARTZ 41120 ELM ST, U STE G
41120 ELM ST, U G MURRIETA, CA 92562-9515
MURRIETA, CA 92562-9515 (951) 225-4666
(951) 378-0603
FEE AMOUNT
FIRE NFPA 13 or 13R System 7- 100 heads $553.00
Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00
Fire Department Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov
Worldwide www.tyco-fire.com Contacts
Series DS
Pendent,
Standard
-1 - 56 k-factor,
Uprighthand Hoi
Response, Stani
Dry-type Sprinklers
'izontal Sidewall
lard Coverage
F
General
Description
TYCO Series DS-1 5.6K Pendent,
Upright, and Horizontal Sidewall, Stan-
dard Response (5 mm bulb), Standard
Coverage Dry-type Sprinklers are dec-
orative glass bulb automatic sprinklers
typically used where:
pendent sprinklers are required on
dry pipe systems that are exposed
to freezing temperatures (e.g., sprin-
kler drops from unheated portions of
buildings)
sprinklers and/or a portion of the
connecting piping may be exposed
to freezing temperatures (e.g., sprin-
kler drops from wet systems into
freezers, sprinkler sprigs from wet
systems into unheated attics, or hor-
izontal piping extensions through a
wall to protect unheated areas of a
building such as loading docks, over-
hangs, and building exteriors)
sprinklers are used on systems that
are seasonably drained to avoid
freezing (e.g., vacation resort areas)
FILTSTM
Series DS-1 Dry-type Sprinklers
described herein must be installed
and maintained in compliance with this
document, as well as with the applica-
ble standards of the NATIONAL FIRE
PROTECTION ASSOCIATION (NFPA),
in addition to the standards of any other
authorities having jurisdiction. Failure
to do so may impair the performance
of these devices.
The owner is responsible for main-
taining their fire protection system
and devices in proper operating con-
dition. Contact the installing contrac-
tor or product manufacturer with any
questions.
Series DS-1 Dry-type Sprinklers must
only be installed in fittings that meet
the requirements of the Design Crite-
ria section.
Sprinkler
Identification
Numbers (SINs)
tIIU
Maximum Working Pressure
175 psi (12,1 bar)
Inlet Thread Connections
1 inch NPT
ISO 7-R 1 1Y3255 - Pendent
1Y3155 - Upright Discharge Coefficient
1Y3355 - Horizontal Sidewall K=5.6 gpm/ps1112 (80,6 pm/ban/2)
IMPORTANT
Refer to Technical Data Sheet
TFP2300 for warnings pertaining to
regulatory and health information.
Always refer to Technical Data
Sheet TFP700 for the "INSTALLER
WARNING" that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
Page 1 of 10
Technical
Data
Approvals
UL and C-UL Listed
FM Approved
VdS Approved
TY3255 w/Standard Escutcheon only
NYC Approved
under MEA 352-01-E
LPCB Approved
Reference No. 094a/11
CE Certified
Certificate of Conformity No. 0832-
CPD-201 5
(Refer to Tables A and B for details.)
AUGUST 2018
Temperature Ratings
Refer to Tables A and B.
Finishes
Sprinkler: Refer to Table D.
Escutcheon: Refer to Table D.
Physical Characteristics
Inlet .............................Copper
Plug .............................Copper
Yoke.......................Stainless Steel
Casing .............Galvanized Carbon Steel
Insert .............................Bronze
Bulb Seat...................Stainless Steel
Bulb (5 mm dia.) .....................Glass
Compression Screw .................Bronze
Deflector ..........................Bronze
Frame ............................Bronze
Guide Tube .................Stainless Steel
Water Tube .................Stainless Steel
Spring .....................Stainless Steel
Sealing Assembly. Beryllium Nickel wfTEFLON
Escutcheon ...................Carbon Steel
TFP500
TFP500
Page 2 of 10
SPRINKLER
TYPE
ESCUTCHEON
TYPE
TEMPERATURE
RATING
BULB
COLOR CODE
SPRINKLER FINISH
NATURAL CHROME
BRASS PL ATED POLYESTER*
PENDENT
(TY3255)
STANDARD
135°F (57°C) Orange
1, 2, 3, 4, 5, 6 1, 2, 4, 5, 6
155°F (68°C) Red
175°F (79°C) Yellow
200°F (93°C) Green
286-F (141-C) Blue
360°F (182°C) Mauve 1, 2, 3, 6 1, 2, 6
RECESSED
135°F (57°C) Orange
12,3,5 12,5
155°F (68°C) Red
175°F (79°C) Yellow
200°F (93°C) Green
286-F (141-C) Blue 1,2
360°F (182°C) Mauve N/A
DEEP
135°F (57°C) Orange
1, 2, 3, 4, 5 1, 2,4, 5
155°F(68°C) Red
175°F (79°C) Yellow
200°F (93°C) Green
286°F (141°C) Blue
360°F (182°C) Mauve
WITHOUT
135°F (57°C) Orange
155°F (68°C) Red
175°F (79°C) Yellow
200°F (93°C) Green
286-F (141-C) Blue
360°F(182°C) Mauve 1,2,3 1,2
UPRIGHT
(1Y3155) WITHOUT
135°F (57°C) Orange
1,2,3,4,5 1,2,4,5
155°F (68°C) Red
175-F (79-C) Yellow
200°F (93°C) Green
286°F (141°C) Blue
360°F (182°C) Mauve 1, 2:3 1,2
Notes:
Listed by Underwriters Laboratories, Inc. (UL), maximum order length of 48 inches
Listed by underwriters Laboratories for use in Canada (C-UL), maximum order length of 48 inches
Approved by FM Global (FM Approvals), maximum order length of 48 inches
Loss Prevention Certification Board (LPCB) and CE conformity apply to these temperature ratings only
Approved by the City of New York under MEA 352-01-B
Approved by vdS
Frame and deflector only
N/A - Not Applicable
TABLE A
SERIES DS-1 PENDENT & UPRIGHT DRY-TYPE SPRINKLERS, 5.6K, STANDARD RESPONSE
LABORATORY LISTINGS AND APPROVALS
TFP500
Page 3 of 10
SPRINKLER ESCUTCHEON TEMPERATURE BULB
SPRINKLER FINISH
NATURAL CHROME
BRASS PLATED POLYESTER*** TYPE TYPE RATING COLOR CODE
135°F (57°C) Orange
155°F (68°C) Red
175°F (79°C) Yellow STANDARD
200°F (93°C) Green
286°F (141°C) Blue
360°F (182°C) Mauve
135°F (57°C) Orange
155°F(68°C) Red
175°F (79°C) Yellow Hsw*
(TY3355) DEEP 1—,2-',3--,4,5 1",2",4,5
200°F (93°C) Green
286°F (141°C) Blue
360°F (182°C) Mauve
135°F (57°C) Orange
155°F (68°C) Red
175°F (79°C) Yellow WITHOUT 200°F (93°C) Green
286°F (141°C) Blue
360°F(182°C) Mauve 1",2'-,5
Notes:
Listed by underwriters Laboratories, Inc. (UL), maximum order length of 48 inches
Listed by Underwriters Laboratories for use in Canada (C-UL), maximum order length of 48 inches
Approved by FM Global (FM Approvals), maximum order length of 48 inches
Loss Prevention Certification Board (LPCB) and CE conformity apply to these temperature ratings only
Approved by the City of New York under MBA 352-01-E
Horizontal sidewall with top of deflector-to-ceiling distance of 4 to 12 inches (10010300 mm(
Light and ordinary hazard occupancies only
Light hazard occupancies only .... Frame and deflector only
TABLE B
SERIES DS-1 HORIZONTAL SIDEWALL (HSW) DRY-TYPE SPRINKLER, 5.6K, STANDARD RESPONSE
LABORATORY LISTINGS AND APPROVALS
PLUG WITH INLET
SEALING
ASSEMBLY
YOKE
SPRING
INLET
BAND
WATER
II II
TUBE CASING
GUIDE - INSERT
TUBE NN
BULB
FRAME j SEAT
5 mm BULB VENT HOLE
COMPRESSION
DEFLECTOR SCREW
FIGURE 1
SERIES DS-1 DRY-TYPE SPRINKLER, 5.6K, STANDARD RESPONSE
ASSEMBLY
-
WRENCH
RECESS
WRENCH I FLAT a
PUSH WRENCH
IN TO ENSURE
ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
FIGURE 2
W-TYPE 7
WRENCH
TFP500
Page 4 of 10
SPRINKLER FITTING
(REFER TO DESIGN
CRITERIA SECTION)
FACE OF
SPRINKLER
FITTING
ORDER LENGTHS:
2-3/4 to 48' 1-3/4 DIA. (69,9 to 1219,2 mm) (44,5 mm)
IN 1/4 (6,4 mm)
INCREMENTS II
I FACE OFIZZZI
CEILING
T
.
DIA. 2-3/16±1/8' (76,2 mm) (55,6 ± 3,2 mm) ___________
FIGURE 3
PENDENT (TY3255)
WITH STANDARD ESCUTCHEON
SPRINKLER FITTING
(REFER TO DESIGN
CRITERIA SECTION)
FACE OF
SPRINKLER
FITTING -
ORDER LENGTHS:
3-3/4" to 48"
(95,3 to 1219,2 mm)
IN 1/4" (6,4 mm) 2-1/4 DIA.
INCREMENTS (57,2 mm)
FACE OF
CEILING
I WI
13/81
FIGURE 4
PENDENT (TY3255)
WITH STANDARD
RECESSED ESCUTCHEON
SPRINKLER FITTING
(REFER TO DESIGN
CRITERIA SECTION)
FACE OF
SPRINKLER
\
FITTING
ORDER LENGTHS: 3-1/2" DIA.
1/2" to 46" (88,9 mm)
(12,7 to 1168,4 mm) I
IN 1/4" (6,4 mm) 21/2" DIA
INCREMENTS (63,5 mm)
FACE OF
CEILING
4-1/4" ± 1/8'
(108,0 ±j32 mm)
FIGURE 5
PENDENT (TY3255)
WITH DEEP ESCUTCHEON
SPRINKLER FITTING
(REFER TO DESIGN
CRITERIA SECTION)
FACE OF
SPRINKLER
FITTING
ORDER LENGTHS:
5" to 48"
(127,0 to 1219,2 mm)
IN 1/4" (6,4 mm)
INCREMENTS
MINIMUM
1-3/4(44,5mm)
DEFLECTOR
TO CEILING
FIGURE 6
PENDENT (TY3255)
WITHOUT ESCUTCHEON
TOP OF
DEFLECTOR
ORDER LENGTHS:
5" to 48"
(127,0 to 1219,2 mm)
IN 1/4" (6,4 mm)
INCREMENTS
FACE OF
SPRINKLER
FITTING
SPRINKLER FITTING
(REFER TO DESIGN
CRITERIA SECTION)
FIGURE 7
UPRIGHT (TY3 155)
WITHOUT ESCUTCHEON
ORDER LENGTHS:
2-3/4" to 48" (69,9 to 1219,2 mm)
IN 1/4" (6,4 mm) INCREMENTS 2-3/8" ± 1/8 -
- (60,3 ± 3,2 mm)
FACE OF FACE OF
- SPRINKLER MOUNTING
FITTING SURFACE
3" DIA.
-3/4DIA./
(76,2 mm)
SPRINKLER FITTING
(REFER TO DESIGN (44,5 mm) CENTERLINE 5/16
CRITERIA SECTION) OF WATERWAY (7,9 mm)
FIGURE 8
HORIZONTAL SIDEWALL (TY3355)
WITH STANDARD ESCUTCHEON
ORDER LENGTHS:
1/2"t045-3/4"(12,7t01162,1 mm)
IN 1/4" (6,4 mm) INCREMENTS
2-1/2" DIA.
FACE OF (63,5 mm) SPRINKLER
FITTING
SPRINKLER FITTING
(REFER TO DESIGN
CRITERIA SECTION)
4-1/4" ± 1/8"
FACE OF - (108,0 ± 3,2 mm)
MOUNTING
SURFACE
_
I
r3.5-
3-1/2" DIA.
(88,9 mm)
CENTERLINE 5/16"
OF WATERWAY (7,9 mm)
FIGURE 9
HORIZONTAL SIDEWALL (TY3355)
WITH DEEP ESCUTCHEON
ORDER LENGTHS:
I 5-1/2' to 48" (139,7 to 1219,2 mm)
IN 1/4" (6,4 mm) INCREMENTS
FACE OF
- SPRINKLER
FITTING
MINIMUM
2-1/4" (57,2 mm)
DEFLECTOR TO
MOUNTING
SURFACE
SPRINKLER FITTING
(REFER TO DESIGN
CRITERIA SECTION)
/ 3o I 5/16' / (7,9 mm)
CENTERLINE
OF WATERWAY
FIGURE 10
HORIZONTAL SIDEWALL (TY3355)
WITHOUT ESCUTCHEON
TFP500
Page 5 of 10
Operation
When TYCO Series DS-1 5.6K Pendent,
Upright, and Horizontal Sidewall, Stan-
dard Response, Standard Coverage
Dry-type Sprinklers are in service,
water is prevented from entering the
assembly by the Plug with Sealing
Assembly (Ref. Figure 1) in the Inlet of
the sprinkler.
The glass bulb contains a fluid that
expands when exposed to heat. When
the rated temperature is reached, the
fluid expands sufficiently to shatter
the glass bulb, and the Bulb Seat is
released.
The compressed Spring is then able
to expand and push the Water Tube as
well as the Guide Tube outward. This
action simultaneously pulls inward on
the Yoke, withdrawing the Plug with
Sealing Assembly from the Inlet, allow-
ing the sprinkler to activate and flow
water.
Design
Criteria
TYCO Series DS-1 5.6K Pendent,
Upright, and Horizontal Sidewall, Stan-
dard Response, Standard Coverage
Dry-type Sprinklers are intended for
use in fire sprinkler systems designed
in accordance with the standard instal-
lation rules recognized by the applica-
ble listing or approval agency (e.g., UL
Listing is based on NFPA 13 require-
ments). For more information on LPCB
Approval, contact Johnson Controls at
the following office:
Kopersteden 1
7547 TJ Enschede
The Netherlands
Tel: +31-(0)53-428-4444
Fax: +31-(0)53-428-3377
Sprinkler Fittings
Install 1 in. NPT Series DS-1 Dry-type
Sprinklers in the 1 in. NPT outlet or run
of the following fittings:
malleable or ductile iron threaded
tee fittings that meet the dimen-
sional requirements of ANSI B16.3
(Class 150)
cast iron threaded tee fittings that
meet the dimensional requirements
of ANSI B16.4 (Class 125)
Do not install Series DS-1 Dry-type
Sprinklers into elbow fittings. The Inlet
of the sprinkler can contact the interior
of the elbow.
The unused outlet of the threaded tee is
plugged as shown in Figure 12.
TFP500
Page 6 of 10
Temperatures for Heated Area(1)
Ambient Temperature 40°F I 50°F 60°F
Exposed to (4°C) (10°C) (16°C)
Minimum Exposed Barrel Length(2), Discharge End of Sprinkler
Inches
(mm)
40°F
(4°C)
0 0 0
30°F
(-1°C)
0 0 0
20°F 4 0 0
(-7°C) (100)
10°F 8 1 0 (-12°C) (200) (25)
0°F 12 3 0 (-18°C) (305) (75)
-10°F 14 4 1
(-23°C) (355) (100) (25)
'-20°F 14 6 3
(-29°C) (355) (150) (75)
-30°F 16 8 4
(-34°C) (405) (200) (100)
-40°F 18 8 4
(-40°C) (455) (200) (100)
-50°F 20 10 6
(-46°C) (510) (255) (150)
-60°F 20 10 6
(-51°C) (510) (255) (150)
Notes:
For protected area temperatures that occur between values listed above, use the next cooler temperature.
These lengths are inclusive of wind velocities up to 30 mph (18,6 kph).
TABLE C
EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS
MINIMUM RECOMMENDED LENGTHS
You can also install Series DS-1 Dry-
type Sprinklers in the 1 inch NPT outlet
of a GRINNELL Figure 730 Mechanical
Tee and GRIN NELL G-FIRE Figure 522;
however, the use of the Figure 730 Tee
and Figure 522 for this arrangement is
limited to wet pipe systems.
The configuration shown in Figure 13
is only applicable for wet pipe systems
where the sprinkler fitting and water-
filled pipe above the sprinkler fitting are
not subject to freezing and where the
length of the dry-type sprinkler has the
minimum exposure length depicted in
Figure 11. Refer to the Exposure Length
section.
For wet pipe system installations of 1
inch NPT Series DS-1 Dry-Type Sprin-
klers connected to CPVC piping, use
only the following TYCO CPVC fittings:
1 in. x 1 in. NPT Female Adapter (P/N
80145)
1 in. x 1 in. x 1 in. NPT Sprinkler Head
Adapter Tee (P/N 80249)
For dry pipe system installations, use
only the side outlet of maximum 2-1/2
inch reducing tee when locating Series
DS-1 Dry-type Sprinklers directly
below the branchline; otherwise, use
the configuration shown in Figure 12 to
assure complete water drainage from
above Series DS-1 Dry-type Sprin-
klers and the branchline. Failure to do
so may result in pipe freezing and water
damage.
NOTICE
Do not install Series DS-1 Dry-type
Sprinklers into any other type fitting
without first consulting the Johnson
Controls. Technical Services. Failure to
use the appropriate fitting may result in
one of the following:
failure of the sprinkler to operate
properly due to formation of ice
over the Inlet Plug or binding of the
Inlet Plug
insufficient engagement of the
Inlet pipe-threads with consequent
leakage
Drainage
In accordance with the minimum
requirements of the NATIONAL FIRE
PROTECTION ASSOCIATION for dry
pipe sprinkler systems, branch, cross,
and feed-main piping connected to Dry
Sprinklers and subject to freezing tem-
peratures must be pitched for proper
drainage.
Exposure Length
When using Dry Sprinklers in wet pipe
sprinkler systems to protect areas
subject to freezing temperatures, use
Table C to determine a sprinkler's
appropriate exposed barrel length to
prevent water from freezing in the con-
necting pipes due to conduction. The
exposed barrel length measurement
must be taken from the face of the
sprinkler fitting to the surface of the
structure or insulation that is exposed
to the heated area. Refer to Figure 11
for an example.
For protected area temperatures
between those given above, the
minimum recommended length from
the face of the fitting to the outside of
the protected area may be determined
by interpolating between the indicated
values.
Clearance Space
In accordance with NFPA 13, when
connecting an area subject to freez-
ing and an area containing a wet pipe
sprinkler system, the clearance space
around the sprinkler barrel of dry-type
sprinklers must be sealed. Due to tem-
perature differences between two
areas, the potential for the formation
of condensation in the sprinkler and
subsequent ice build-up is increased. If
this condensation is not controlled, ice
build-up can occur that might damage
the dry-type sprinkler and/or prevent
proper operation in a fire situation.
Use of the Model DSB-2 Dry Sprinkler
Boot, described in technical data sheet
TFP591 and shown in Figures 14 and
15, can provide the recommended seal.
TFP500
Page 7 of 10
FACE OF
SPRINKLER - -
FITTING
I EXPOSURE
_________ • LENGTH
(SEE DESIGN
DSB-2 CRITERIA
INTENDED SECTION)
FOR FREEZER
STRUCTURES
FIGURE 11
EXPOSURE LENGTH
QIL RUN
OUTLET
PLUGGED
SPRINKLER
FITTING TO DRY (SEE-DESIGN SYSTEM CRITERIA
SECTION)
DSB-2
INTENDED
FOR FREEZER 4 STRUCTURES
FIGURE 12
SPRINKLER FITTING
UNHEATED AREA
TO WET SIDE
SYSTEM OUTLET
ri P5UGGED
Icon
DSB-2 SPRINKLER
INTENDED FITTING
FOR FREEZER (SEE DESIGN
STRUCTURES CRITERIA
SECTION)
FIGURE 13
SPRINKLER FITTING
HEATED AREA
STRAP TIES
(ENDS ON
-OPPOSING
SIDES OF
BOOT)
DSB-2 BOOT
1-3/4 DIA.
(44,5 mm)
CLEARANCE
HOLE
INSULATED
-FREEZER
STRUCTURE
DS-1
SHOWN WITH
STANDARD
ESCUTCHEON
FIGURE 14
MODEL DSB-2 DRY SPRINKLER
BOOT WITH PENDENT SERIES
DS-1 DRY-TYPE SPRINKLER
1-3/4 DIA.
(44,5 mm)
CLEARANCE INSULATED HOLE FREEZER
ADHESIVE STRUCTURE
BOOT
STRAP TIES DS-1 (ENDS ON SHOWN WITH OPPOSING STANDARD SIDES OF ESCUTCHEON BOOT)
FIGURE 15
MODEL DSB-2 DRY SPRINKLER
BOOT WITH SIDEWALL SERIES
DS-1 DRY-TYPE SPRINKLER
TFP500
Page 8 of 10
Installation
TYCO Series DS-1 5.6K Pendent,
Upright, and Horizontal Sidewall, Stan-
dard Response, Standard Coverage
Dry-type Sprinklers must be installed
in accordance with this section.
General Instructions
Series DS-1 Dry-type Sprinklers must
only be installed in fittings that meet
the requirements of the Design Crite-
ria section. Refer to the Design Criteria
section for other important require-
ments regarding piping design and
sealing of the clearance space around
the Sprinkler Casing.
Do not install any bulb-type sprinkler
if the bulb is cracked or there is a loss
of liquid from the bulb. With the sprin-
kler held horizontally, a small air bubble
should be present. The diameter of the
air bubble is approximately 1/16 inch
(1,6 mm) for the 135°F (57°C) rating to
1/8 inch (3,2 mm) for the 360°F (182°C)
rating.
Obtain a leak-tight 1 inch NPT sprinkler
joint by applying a minimum-to-maxi-
mum torque of 20 to 30 lb-ft (26,8 to
40,2 Nm). Higher levels of torque may
distort the sprinkler Inlet with conse-
quent leakage or impairment of the
sprinkler.
Do not attempt to compensate for
insufficient adjustment in an Escutch-
eon Plate by under or over-tightening
the Sprinkler. Re-adjust the position of
the sprinkler fitting to suit.
Notes:
Install pendent sprinklers only in
the pendent position; install upright
sprinklers only in the upright posi-
tion. The deflector of a pendent or
upright sprinkler is to be parallel to
the ceiling.
Install horizontal sidewall sprinklers
in the horizontal position with their
centerline of waterway perpendicu-
lar to the back wall and parallel to
the ceiling. Ensure the word "TOP"
on the Deflector faces the ceiling.
Step 1. With a non-hardening pipe-
thread sealant such as TEFLON applied
to the inlet threads, hand-tighten the
sprinkler into the sprinkler fitting.
Step 2. Wrench-tighten the sprinkler
using either:
a pipe wrench on the Inlet Band or
the Casing (Ref. Figure 1)
the W-Type 7 Sprinkler Wrench on
the Wrench Flat (Ref. Figure 2)
Apply the wrench recess of the W-Type
7 Sprinkler Wrench to the wrench flat.
Note: If sprinkler removal becomes
necessary, remove the sprinkler using
the same wrenching method noted
above. Sprinkler removal is easier when
a non-hardening sealant was used
and torque guidelines were followed.
After removal, inspect the sprinkler for
damage.
Step 3. After installing the ceiling or
wall and applying a ceiling finish, slide
on the outer piece of the escutch-
eon until it comes in contact with the
ceiling/wall. Do not lift the ceiling panel
out of its normal position.
When using the Deep Escutcheon,
hold the outer piece in contact with the
mounting surface (ceiling or wall). Then
rotate the inner piece approximately 1/4
turn with respect to the outer piece,
to hold the Deep Escutcheon firmly
together.
Care and
Maintenance
TYCO Series DS-1 5.6K Pendent,
Upright, and Horizontal Sidewall,
Standard Response, Standard Cover-
age Dry-type Sprinklers must be main-
tained and serviced in accordance with
this section.
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system
that it controls, obtain permission to
shut down the affected fire protection
systems from the proper authorities
and notify all personnel who may be
affected by this action.
Absence of the outer piece of an
escutcheon, which is used to cover a
clearance hole, may delay the time to
sprinkler operation in a fire situation.
A Vent Hole is provided in the Bulb
Seat (Ref. Figure 1) to indicate if the Dry
Sprinkler is remaining dry. Evidence of
leakage from the Vent Hole indicates
potential leakage past the Inlet seal
and the need to remove the sprinkler
to determine the cause of leakage;
for example, an improper installation
or an ice plug. Close the fire protec-
tion system control valve and drain the
system before removing the sprinkler.
Sprinklers which are found to be
leaking or exhibiting visible signs of
corrosion must be replaced.
Automatic sprinklers must never be
painted, plated, coated, or other-
wise altered after leaving the factory.
Modified sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing it with a soft bristle brush.
Care must be exercised to avoid
damage to the sprinklers before,
during, and after installation. Sprin-
klers damaged by dropping, striking,
wrench twist/slippage, or the like, must
be replaced. Also, replace any sprin-
kler that has a cracked bulb or that has
lost liquid from its bulb (Ref. Installa-
tion section).
The owner is responsible for the inspec-
tion, testing, and maintenance of their
fire protection system and devices in
compliance with this document, as well
as with the applicable standards of the
NATIONAL FIRE PROTECTION ASSO-
CIATION (e.g., NFPA 25), in addition to
the standards of any other authorities
having jurisdiction. Contact the install-
ing contractor or product manufacturer
with any questions.
Automatic sprinkler systems are rec-
ommended to be inspected, tested,
and maintained by a qualified Inspec-
tion Service in accordance with local
requirements and/or national codes.
SPRINKLER
FINISH
CHROME 0 PLATED
NATURAL 1 BRASS
ESCUTCHEON FIN 1514(11
SIGNAL WHITE
(RAL9003)
POLYESTER
SIGNAL WHITE
(RAL9003)
POLYESTER
2 I NATURAL I BRASS I BRASS PLATED
SIGNAL WHITE SIGNAL WHITE
4 (RAL9003) (RAL9003)
POLYESTER POLYESTER
CHROME CHROME
PLATED PLATED
I
_L
TEMPERATURE
RATING(2)
0 135-F (57-C)
1 155-F (68-C).
2 175°F(79°C)
3 200°F(93°C)
4 286-F (141-C)
5 1 360°F(182°C)
ORDER
LENGTH(3)
055 5.50 in.
082 8.25 in.
180 18.00 in.
187 18.75 in.
372 37.25 in.
480 48.00 in.
TFP500
Page 9 of 10
PIN* 60
-. XXX - X - XXX
SIN
96 Pendent with TY3255
Standard Escutcheon (1 in. NPT) (Figure 3)
93 Pendent with TY3255
Deep Escutcheon (1 in. NPT) (Figure 5)
97 Pendent with TY3255
Recessed Escutcheon (1 in. NPT) (Figure 4)
92 Pendent without 1Y3255
Escutcheon (1 in. NPT) (Figure 6)
Sidewall with TY3355 94 Standard Escutcheon (1 in. NPT) (Figure 8)
53 Sidewall with 1Y3355
Deep Escutcheon (1 in. NPT) (Figure 9)
54 Sidewall without TY3355
Escutcheon (1 in. NPT) (Figure 10)
Upright without I TY3155 I I Escutcheon (1 in. NPT) I (Figure 7) I
Notes:
Escutcheon Finish applies to sprinklers provided with escutcheons.
360'F 1182"Cl temperature rating applies to non-recessed sprinkler
assemblies.
Dry-type Sprinklers are furnished based upon "Order Length" as mea-
sured per Figures 3 through tO, as applicable, and for each individual
sprinkler where it is to be installed. After the measurement is taken,
round it 10 the nearest 1/4 inch increment.
Use Prefix I" for ISO 7-R 1 Connection (eg., 1-60-961-1-180).
TABLED
SERIES DS-1 DRY-TYPE SPRINKLERS, 5.6K, STANDARD RESPONSE
PART NUMBER SELECTION
Limited
Warranty
For warranty terms and conditions, visit
www.tyco-fire.com.
Ordering
Procedure
Contact your local distributor for avail-
ability. When placing an order, indi-
cate the full product name, including
description and part number (P/N).
Dry-type Sprinklers
When ordering Series DS-1 5.6K
Pendent, Upright, and Horizontal Side-
wall, Standard Response, Standard
Coverage Dry-type Sprinklers, specify
the following information:
SIN:
TY3255 - Pendent
TY3155 - Upright
TY3355 - Horizontal Sidewall
Order Length:
Dry-type Sprinklers are furnished
based upon Order Length as mea-
sured per Figures 3 through 10, as
applicable. After the measurement is
taken, round it to the nearest 1/4 inch
increment.
Inlet Connections:
1 Inch NPT
(Standard)
ISO 7-R 1
(For information on ISO Inlet Thread
Connections, contact your Johnson
Controls Sales Representative.)
Temperature Rating
Sprinkler Finish
Escutcheon Type and Finish, as
applicable
P/N from Table
Part numbers are for 1 inch NPT
standard order sprinklers. Orders
for all other sprinkler assemblies
must be accompanied by a complete
description.
Sprinkler Wrench
Specify W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001
Sprinkler Boot
Specify Model DSB-2 Dry Sprinkler
Boot, P/N 63-000-0-002
This part number includes one (1) Boot,
two (2) Strap Ties, and 1/3 oz. of Adhe-
sive (a sufficient quantity for installing
one boot).
TFP500
Page 10 of 10
1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700
C 2018 Johnson Controls. All rightsrusorvod. All specifications and other information shown were currant as of document revision date and are subject to Change without notice. Johnson '1
NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are IegiOIered trademarks at National El,, P,nlevtlnndanacwlinn: Controls TEFLON isa,ngiolornd IrtdnnraA or DuPOnt
tqcu Worldwide I
Contacts I www.tyco-fire.com
Series TYFRB - 28,42,5,6, and 8,0 K-Factor
Upright, Pendent, and Recessed Pendent Sprinklers
Quick Response, Standard Coverage
General
Description
The TYCO Series TY-FRB 2.8, 4.2, 5.6,
and 8.0 K-factor Upright, Pendent,
and Recessed Pendent Sprinklers
described in herein are quick response,
standard coverage, decorative 3 mm
glass bulb-type spray sprinklers. They
are designed for use in light or ordinary
hazard, commercial occupancies such
as banks, hotels, and shopping malls.
The TY-FRB Recessed Pendent Sprin-
kler, where applicable, is intended for
use in areas with a finished ceiling. This
recessed pendent sprinkler uses one of
the following Recessed Escutcheons:
A two-piece Style 10 (1/2 in. NPT)
or Style 40 (3/4 in. NPT) Recessed
Escutcheon with 1/2 in. (12,7 mm) of
recessed adjustment or up to 3/4 in.
(19,1 mm) of total adjustment from
the flush pendent position.
A two-piece Style 20 (1/2 in. NPT)
or Style 30 (3/4 in. NPT) Recessed
Escutcheon with 1/4 in. (6,4 mm) of
recessed adjustment or up to 1/2 in.
(12,7 mm) of total adjustment from
the flush pendent position.
The adjustment provided by the
Recessed Escutcheon reduces the
accuracy to which the fixed pipe drops
to the sprinklers must be cut.
Corrosion-resistant coatings, where
applicable, are utilized to extend the
life of copper alloy sprinklers beyond
what would be obtained when exposed
IMPORTANT
Refer to Technical Data Sheet
TFP2300 for warnings pertaining to
regulatory and health information.
Always refer to Technical Data
Sheet TFP700 for the "INSTALLER
WARNING" that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
Page 1 of 10
to corrosive atmospheres. Although
corrosion-resistant coated sprinklers
have passed the standard corrosion
tests of the applicable approval agen-
cies, the testing is not representative
of all possible corrosive atmospheres.
Consequently, it is recommended that
the end user be consulted with respect
to the suitability of these coatings for
any given corrosive environment. The
effects of ambient temperature, con-
centration of chemicals, and gas/
chemical velocity, should be consid-
ered, as a minimum, along with the cor-
rosive nature of the chemical to which
the sprinklers will be exposed.
An intermediate level version of the
Series TY-FRB Pendent Sprinklers
is detailed in Technical Data Sheet
TFP356. Sprinkler Guards are detailed
in Technical Data Sheet TFP780.
The Series TY-FRB 2.8, 4.2, 5.6,
and 8.0 K-factor Upright, Pendent,
and Recessed Pendent Sprinklers
described herein must be installed
and maintained in compliance with
this document and with the applicable
standards of the National Fire Protec-
tion Association (NFPA), in addition to
the standards of any authorities having
jurisdiction. Failure to do so may impair
the performance of these devices.
The owner is responsible for maintain-
ing their fire protection system and
devices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted with
any questions.
NFPA 13 prohibits installation of 1/2 in.
NPT sprinklers with K-factors greater
than 5.6 in new construction. They are
intended for retrofit in existing sprinkler
systems only.
JULY 2018
Sprinkler
Identification
Number (SIN)
TY1131 . . . Upright 2.8K, 1/2 in. NPT
TY1231.. Pendent 2.8K, 1/2 in. NPT
1Y2131 . . . Upright 4.2K, 1/2 in. NPT
1Y2231.. Pendent 4.2K, 1/2 in. NPT
TY3131 . . . Upright 5.6K, 1/2 in. NPT
1Y3231.. Pendent 5.6K, 1/2 in. NPT
1Y4131 . . . Upright 8.0K, 3/4 in. NPT
TY4231.. Pendent 8.0K, 3/4 in. NPT
TY4831 . . . Upright 8.0K, 1/2 in. NPT
1Y4931.. Pendent 8.0K, 1/2 in. NPT
Technical
Data
Approvals
UL and C-UL Listed
FM, LPCB, and NYC Approved
Refer to Table A and B for complete approval information including corrosion-resistant
status.
Maximum Working Pressure
Refer to Table C
TFPI7I
H- 2-7/8" (73,0 mm) DIA. -H
RECESSED PENDENT CROSS SECTION
TFPI7I
Page 2 of 10
* Temperature rating ** Pipe thread connections per 1 - Frame
is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button
Deflector. special request. PLATE SEATING
SURFACE
7/16
(11,1 mm)
NOMINAL 2-1/4
16"
MAKE-IN (57,2 mm)
2-3/ I
(55,6 mm) 1-9/16
Lq_~ 1
(39,7 mm) I
1/2 NPT** t WRENCH STYLE 10or20
FLATS RECESSED
UPRIGHT PENDENT ESCUTCHEON
3 - Sealing 5 - Compression
Assembly Screw
4 - Bulb 6 - Deflector*
7 - Bushing
'•a
CROSS SECTION
2-7/8" (73,0mm) DIA.
RECESSED PENDENT
FIGURE 1
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY113I) AND PENDENT (TY1231) SPRINKLERS
2.8 K-FACTOR, 1/2 IN. NPT
* Temperature rating ** Pipe thread connections per 1 - Frame
is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button
Deflector, special request. PLATE SEATING
SURFACE
IMAKE-IN
7/16"
,1 mm)(11
2-3/16" NOMINAL
(55,6mm)
(55,6 mm)
1/2" NPT** I WRENCH STYLE 10 or 20
FLATS RECESSED
UPRIGHT PENDENT ESCUTCHEON
3 - Sealing 5 - Compression
Assembly Screw
4 - Bulb 6 - Deflector*
FIGURE 2
QUICK RESPONSE SERIES TV-FRB UPRIGHT (TV2 131) AND PENDENT (TY2231) SPRINKLERS
4.2 K-FACTOR, 1/2 IN. NPT
Discharge Coefficient
K=2.8 GPM/p5i½ (40,3 LPM/bar½)
K=4.2 GPM/p5i½ (60,5 LPM/bar½)
K=5.6 GPM/p5i½ (80,6 LPM/bar)
K=8.0 GPM/p5i½ (115,2 LPM/bar½)
Temperature Rating
Refer to Table A and B
Finishes
Sprinkler: Refer to Table D
Recessed Escutcheon: Signal or Pure White,
Grey Aluminum, Jet Black, Chrome Plated,
or Natural Brass
Physical Characteristics
Frame ............................Bronze
Button ......................Brass/Copper
Sealing Assembly. Beryllium Nickel w/TEFLON
Bulb...............................Glass
Compression Screw .................Bronze
Deflector ...................Copper/Bronze
Bushing (K=2.8) ....................Bronze
Poly-Stainless
Physical Characteristics
Frame ............................Bronze
Button ................L316 Stainless Steel
Bulb ............................. .. Glass
Compression Screw .....L316 Stainless Steel
Deflector ...................Copper/Bronze
Sealing Assembly. Gold Plated Beryllium Nickel
w/TEFLON
'Type L316 stainless steel lUNS 316031 per ASTM
A479/479M or BS EN 1008 WN1.4404.
Operation
The glass bulb contains a fluid that
expands when exposed to heat. When
the rated temperature is reached, the
fluid expands sufficiently to shatter the
glass bulb, allowing the sprinkler to
activate and water to flow.
Design
Criteria
The TYCO Series TY-FRB 2.8, 4.2, 5.6,
and 8.0 K-factor Upright, Pendent,
and Recessed Pendent Sprinklers are
intended for fire protection systems
designed in accordance with the stan-
dard installation rules recognized by
the applicable Listing or Approval
agency, such as UL Listing based on
the requirements of NFPA 13 and FM
Approval based on the requirements
of the FM Global Loss Prevention Data
Sheets. Use only the style 10, 20, 30, or
40 Recessed Escutcheon, as applica-
ble, for recessed pendent installations.
I I !
2-7/8" (73,0 mm) DIA.
RECESSED PENDENT CROSS SECTION
TFPI7I
Page 3 of 10
* Temperature rating ** Pipe thread connections per
is indicated on ISO 7-1 can be provided on
Deflector. special request.
1 - Frame 3 - Sealing 5 - Compression
2 - Button Assembly Screw
4 - Bulb 6 - Deflector* ESCUTCHEON
PLATE SEATING
SURFACE
I N
7/16
_______ ______(11,1 mm)
OMINAL I
MAK 2-3/16
(55,6 mm)
1-1/2'
E-lN I 2-3/16"
(38,1 mm) (55,6 mm)
1/2" NPT** I WRENCH STYLE 10 or 20
FLATS RECESSED
UPRIGHT PENDENT ESCUTCHEON CROSS SECTION
2-7/8" (73,0 mm) DIA.
RECESSED PENDENT
ALL FINISHES EXCEPT POLY-STAINLESS
WRENCH 1/2" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature
FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated
SURFACE 4 - Bulb 6 - Deflector * on Deflector.
(11 1 mm)
NOMINAL I
(55,6 mm) 11.11/2
I
7/16"
2-3/16" MAKE-IN (55,6 mm)
2-3/16'
STYLE 10
RECESSED
UPRIGHT PENDENT ESCUTCHEON
POLY-STAINLESS FINISH ONLY
FIGURE 3
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS
5.6 K-FACTOR, 1/2 IN. NPT
Installation
The TYCO Series TY-FRB 2.8, 4.2, 5.6,
and 8.0 K-factor Upright, Pendent, and
Recessed Pendent Sprinklers must
be installed in accordance with this
section.
General Instructions
Do not install any bulb type sprinkler
if the bulb is cracked or there is a loss
of liquid from the bulb. With the sprin-
kler held horizontally, a small air bubble
should be present. The diameter of the
air bubble is approximately 1/16 in.
(1,6 mm) for the 135°F (57°C) and
3/32 in. (2,4 mm) for the 286°F (141°C)
temperature ratings. A leak-tight 1/2 in.
NPT sprinkler joint should be obtained
by applying a minimum-to-maximum
torque of 7 to 14 lb-ft (9,5 to 19,0 Nm).
A leak tight 3/4 in. NPT sprinkler joint
should be obtained with a torque of
10 to 20 lb-ft (13,4 to 26,8 N.m). Higher
levels of torque can distort the sprinkler
inlet and cause leakage or impairment
of the sprinkler. Do not attempt to com-
pensate for insufficient adjustment in
the escutcheon plate by under- or over-
tightening the sprinkler. Re-adjust the
position of the sprinkler fitting to suit.
Series TY-FRB Upright and Pendent
Sprinklers
The Series TY-FRB Upright and
Pendent Sprinklers must be installed
in accordance with the following
instructions:
Step 1. Install pendent sprinklers in the
pendent position. Install upright sprin-
klers in the upright position.
Step 2. With pipe thread sealant
applied to the pipe threads, hand-
tighten the sprinkler into the sprinkler
fitting.
Step 3. Tighten the sprinkler into the
sprinkler fitting using only the W-Type 6
Sprinkler Wrench (Ref. Figure 14). With
reference to Figure 1 to Figure 5, apply
the W-Type 6 Sprinkler Wrench to the
sprinkler wrench flats.
Series TY-FRB Recessed Pendent
Sprinklers
The Series TY-FRB Recessed Pendent
Sprinklers must be installed in accor-
dance with the following instructions:
Step 1. After installing the Style 10, 20,
30, or 40 Mounting Plate, as applica-
ble, over the sprinkler threads and with
pipe-thread sealant applied to the pipe
threads, hand-tighten the sprinkler into
the sprinkler fitting.
Step 2. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
7 Recessed Sprinkler Wrench (Ref.
Figure 15). With reference to Figure 1 t
4, apply the W-Type 7 Recessed Sprin-
kler Wrench to the sprinkler wrench
flats.
Step 3. After the ceiling is installed or
the finish coat is applied, slide on the
Style 10, 20, 30, or 40 Closure over
the Series TY-FRB Recessed Pendent
Sprinkler and push the Closure over the
Mounting Plate until its flange comes in
contact with the ceiling.
2-7/8" (73,0 mm) DIA.
RECESSED PENDENT CROSS SECTION
TFPI7I
Page 4 of 10
* Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression
is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw
Deflector. special request. PLATE SEATING 4 Bulb 6 - Deflector*
SURFACE
NNOMINAL
1/2
(12,7 mm)t 2-5/16
FY _____ (58,7 mm) MAKE-IN
2-1/4 1-9/16" I
Wo1__r___,
mrn,/i (39,7 mm) I t (57,2
3/4" NPT I WRENCH STYLE 30 or 40
FLATS RECESSED
UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION
ALL FINISHES EXCEPT POLY-STAINLESS
WRENCH 3/4" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature
FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated
SURFACE 4 - Bulb 6 - Deflector* on Deflector.
2-7/8" (73,0 mm) DIA.
UPRIGHT
1/2"
(12,7 mm)
MAKE-IN (58,7 mm)
NOMINAL 2-5/16"
(57,2 mm)
STYLE 40
RECESSED
PENDENT ESCUTCHEON
POLY-STAINLESS FINISH ONLY
FIGURE 4
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS
8.0 K-FACTOR, 3/4 IN. NPT
CEILING PLATE 1 - Frame 5 - Compression
SEATING SURFACE 2 - Button Screw
Assembly
4 - Bulb
7/16"
(11,1 mm) (57,2 mm)
_________
/
3 - Sealing 6 - Deflector *
MAKE-IN indicated on Deflector.
m
1-9/16" I 23/16
NOMINAL * Temperature rating is
** Pipe thread connections
(39,7 mm) (55,6m)
per 1507-1 can be
provided on special 6 *
1/2 NPT** I WRENCH request.
FLATS UPRIGHT PENDENT CROSS SECTION
FIGURE 5
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS
8.0 K-FACTOR, 112 IN. NPT
TFPI7I
Page 5 of 10
- 27/8" DIA.
5/8±1/4
(73,0 mm) 3/4° (19,1 mm)
(15,9±6,4 mm)
/
I i/4' (6,4 mm) I
FACE OF
- 2-1/4 DIA.
(57,2 mm) MOUNTING
SPRINKLER PLATE
FITTING
1/8'
(3,2 mm)
$11
MOUNTING /
SURFACE/'
CLOSURE SERIES 1-5/16' (333 mm)j
TYFRB 13/16" (20,6 mm)
FIGURE 6
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON
2.8 K-FACTOR, 1/2 IN. NPT
2-7/8" DIA.
5/8±1/4"
(73,0 mm) 3/4" (19,1 mm)
(15,9±6,4 mm) 2-1/4" DIA. J 1/4" (6,4 mm)
/ FACE OF - (57,2 mm)
MOUNTING SPRINKLER PLATE _1
FITTING
1/8" / (3,2 mm)
-_____
MOUNTING
SURFACE
SERIES 1-1/4" (31,8 mm) CLOSURE TY-FRB 3/4' (19,1 mm)
FIGURE 8
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON
4.2 K-FACTOR, 1/2 IN. NPT
- 2-7/8" DIA.
1/2±1/8" (73,0 mm) 1/2(12,7mm)
(12,7±3,2 mm) 2-1/4" DIA. I 1/4" (6,4 mm) I / FACE OF (57,2 mm) MOUNTING
SPRINKLER PLATE
FITTING
1/8"
(3,2 mm)
71.
MOUNTING $ $ \
/k
J
SURFACE
CLOSURE SERIES
TY-FRB 1-1/16" (27,0 mm)
FIGURE 7
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 20 RECESSED ESCUTCHEON
2.8 K-FACTOR, 1/2 IN. NPT
2-7/8" DIA. -
-.
1/2±1/8"
(73,0 mm) 1/2" (12,7 mm)
(12,7±3,2 mm) 2-1/4" DIA. 1/4° (6,4 mm) / FACE OF I (57,2 mm) MOUNTING
PLATE I SPRINKLER -'\
.1
I FITTING I
1/8' I LI (3,2 mm I
MOUNTING /
1
SURFACE
/
SERIES 1-1 (31,8mm) CLOSURE /4" TY-FRB 1" (25,4 mm)
FIGURE 9
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 20 RECESSED ESCUTCHEON
4.2 K-FACTOR, 1/2 IN. NPT
TFPI7I
Page 6 of 10
2-7/8 DIA. -
5/8±1/4"
(73,0 mm) I 3/4" (19,1 mm)
(15,9±6,4 mm) 2-1/4' DIA. 1/4" (6,4 mm) I
PLATE I SPRINKLER
FITTING
1/8'
/ FACE OF (57,2 mm) MOUNTING
(3,2 mm)
\4
MOUNTING
SURFACE
SERIES 1-1/4' (31,8 mm) CLOSURE TY-FRB 3/4" (19,1 mm)
FIGURE 10
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON
5.6 K-FACTOR, 1/2 IN. NPT
2-7/8" 01k
(73,0 mm) 3/4" (19,1 mm)
2-1/4" DIA. 1/4" (6,4 mm) I
(57,2 mm) MOUNTING
PLATE I
1/8" I
(3,2 mm)
MOUNTING
SURFACE
CLOSURE SERIES 1-5/1;(33,3 mm)1
TY-FRB 13/16" (20,6 mm)
FIGURE 12
SERIES TV-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 40 RECESSED ESCUTCHEON
8.0 K-FACTOR, 3/4 IN. NPT
WRENCH RECESS
(END "A" USED FOR
1/2" NPT MODELS)
WRENCH RECESS
(END "B" USED FOR
3/4" NPT MODELS)
FIGURE 14
W-TYPE 6 SPRINKLER
WRENCH
- 2-7/8" DIA.
(73,0 mm) 1/2±1/8" 1/2k (12,7 mm)
/ FACE OF 2 mm)
(12 7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm)
(57, MOUNTING
''?-
- I SPRINKLER PLATE I FITTING
1/8" /
Lq
(3,2 mm)
J .
MOUNTING
SURFACE
SERIES 1-1/4(31,8mm) - CLOSURE TY-FRB 1" (25,4 mm)
FIGURE 11
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 20 RECESSED ESCUTCHEON
5.6 K-FACTOR, 1/2 IN. NPT
2-7/8" DIA.
1/2±1/8" (73,0 mm) 1/2" (12,7 mm)
(12,7±3,2 mm) 2-1/4" DIA 1/4" (6,4 mm)
/ FACE OF - (57,2 mm) MOUNTING
SPRINKLER PLATE
FITTING
1/8"
(3,2 mm) ,
MOUNTING
SURFACE
CLOSURE SERIES 1-5/16" (33,3 mm)1
TY-FRB 1-1/16" (27,0 mm)
FIGURE 13
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 30 RECESSED ESCUTCHEON
8.0 K-FACTOR, 3/4 IN. NPT
WRENCH
RECESS
PUSH WRENCH
IN TO ENSURE
ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
FIGURE 15
W-TYPE 7 RECESSED
SPRINKLER WRENCH
5/8±1/4"
(15,9±6,4 mm)
FACE OF
SPRINKLER
FITTING
TFPI7I
Page 7 of 10
Sprinkler Finish5
K- Type Temperature Bulb Bulb Liquid
Color
Natural
Brass Chrome Plated PolyesterC
Pendent
(TY1231)
and
Upright
(TY1131)
135°F (57°C) Orange
1, 2, 3, 4
155°F (68°C) Red
175°F (79°C) Yellow
200°F (93°C) Green
286°F (141°C) Blue
2.8
1/2 in. NPT
Recessed
Pendent (TY1231)a
Figure 6
135°F (57°C) Orange
1,2,4
155°F (68°C) Red
175°F (79°C) Yellow
200°F (93°C) Green
Recessed
Pendent (TY1231)b
Figure 7
135°F(57°C) Orange
155°F (68°C) Red
175°F (79°C) Yellow
200°F (93°C) Green
4.2
1/2 in. NPT
Pendent
(1Y2231)
and
Upright
(TY2131)
135°F (57°C) Orange
1,2
155°F (68°C) Red
175°F (79°C) Yellow
200°F (93°C) Green
286°F (141°C) Blue
Recessed
Pendent
(TY2231)a
Figure 8
135°F(57°C) Orange
155°F (68°C) . Red
175°F (79°C) Yellow
200°F (93°C) Green
Recessed
Pendent (TY2231)b
Figure 9
135°F (57°C) Orange
155°F (68°C) Red
175°F (79°C) Yellow
200°F (93°C) Green
NOTES
Installed with Style 10(1/2 in. NPT) or Style 40 13/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable.
Installed with Style 20 (1/2 in. NPT) or Style 30(3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable.
Frame and Deflector only.
Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers.
Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers.
Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers.
Approved by the City of New York under MEA 354-01-E.
Where Polyester Coated Sprinklers are noted lobe UL and C-UL Listed, the sprinklers are UL and C-UL Listed, the sprinklers are UL and C-UL Listed as corrosion-
resistant sprinklers.
TABLE A
LABORATORY LISTINGS AND APPROVALS FOR
2.8 AND 4.2 K-FACTOR SPRINKLERS
TFPI7I
Page 8 of 10
Sprinkler. Fin ish8
K-
Factor Type Temperature Bulb Liquid
Color
Natural
Brass
I Chrome
Plated Polyester° PolyStainlessc Lead
Coated
Pendent
(TY3231)
135°F (57°C) Orange
155°F (68°C) Red
175°F (79°C) Yellow . and 1, 2, 3, 4, 5, 6, 7 1,2 1, 2, 3, 5
Upright
(1Y3131)
Blue
200°F (93°C) Green
286°F (141°C)
135°F (57°C) Orange
155°F (68°C) Red 5.6
1/din
NPT
Recessed
Pendent
(TY3231)a
Figure 10
1, 2, 4, 5 1,2 N/Ad 175°F (79°C) Yellow
200°F (93°C) Green
286°F (141°C) Blue
135°F(57°C) Orange
155°F (68°C) Red Recessed
Pendent
(TY3231)b 1, 2, 3, 4, 5 N/A N/A 175°F (79°C) Yellow
200°F (93°C) Green Figure 11
286°F (141°C) Blue
Pendent
(TY4231)
135°F (57°C) Orange
155°F (68°C) Red
175°F (79°C) Yellow and 1,2,3,4, 5, 6, 7 1,2 1,2,5
Upright
(1Y4131)
Blue
200°F (93°C) Green
286-F (141-C)
135°F (57°C) Orange
155°F (68°C) Red 8.0
3 /4 in
NPT
Recessed
Pendent
(1Y4231)a
Figure 12
1,2, 5 1,2 N/A 175°F (79°C) Yellow
200°F (93°C) Green
286°F (141°C) Blue
135°F (57°C) Orange
155°F (68°C) Red Recessed
Pendent
(TY4231)b 1, 2, 3, 5 N/A N/A 175°F (79°C) Yellow
200°F (93°C) Green Figure 13
286°F (141°C) Blue
8.0
Pendent
(TY4931)
135°F (57°C) Orange
155°F (68°C) Red
175°F (79°C) Yellow 1/2 in. and 1, 2, 4, 5, 6 N/A 1, 2, 5
NPT Upright
(TY4831) Blue
200°F (93°C) Green
286°F (141°C)
NOTES
Installed with Style 10(1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable.
Installed with Style 20(1/2 in. NPT) or Style 30 (3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable.
Frame and Deflector only.
Not Available (N/A)
Listed by underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers.
Listed by underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers.
Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers.
Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04( as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed
sprinklers.
Approved by the City of New York under MEA 354-01-E.
VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.)
Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers.
Where Polyester Coaled and Lead-Coaled Sprinklers are noted lobe UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where
Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers.
TABLE B
LABORATORY LISTINGS AND APPROVALS FOR
5.6 AND 8.0 K-FACTOR SPRINKLERS
TFPI7I
Page 9 of 10
Sprinkler Finish
K-
Factor Type Natural
Brass
I Chrome
Plated .1
I Polyester Lead Coated
Pendent (TY1231)
and
2.8 Upright (TY1131)
1/2 in. 175 psi (12,1 bar) N/A2
NPT Recessed
Pendent (TV1231)
Pendent (TY2231)
and
4.2 Upright (TY2131)
1/2 in. 175 psi (12,1 bar) N/A
Recessed NPT
Pendent (TY2231)
Pendent (TY3231)
and
5.6 Upright (TY3131) 250 psi (17,2 bar)
1/2 in. or 175 psi (12,1 bar)'
Recessed NPT
Pendent (TY3231)
Pendent (TY4231) 175 psi
8.0
and
Upright (TY4131) (12,1 bar)
3/4 in. 175 psi (12,1 bar)
Recessed N/A
NPT
Pendent(TY4231)
8.0 Pendent (TY4931) 175 psi 1/2 in. and 175 psi (12,1 bar) (12,1 bar) NPT Upright (TY4831)
NOTES
The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Under-
writers Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York.
Not applicable (N/A).
Care and
Maintenance
The TYCO Series TY-FRB 2.8, 4.2, 5.6,
and 8.0 K-factor Upright, Pendent, and
Recessed Pendent Sprinklers must be
maintained and serviced in accordance
with this section. Before closing a fire
protection system main control valve
for maintenance work on the fire pro-
tection system that it controls, obtain
permission to shut down the affected
fire protection systems from the proper
authorities and notify all personnel who
may be affected by this action.
Absence of the outer piece of an
escutcheon, which is used to cover
a clearance hole, can delay sprinkler
operation in a fire situation.
Sprinklers which are found to be
leaking or exhibiting visible signs of
corrosion must be replaced.
Automatic sprinklers must never be
painted, plated, coated, or other-
wise altered after leaving the factory.
Modified sprinklers must be replaced.
Sprinklers that have been exposed to
TABLE C
MAXIMUM WORKING PRESSURE
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing it with a soft bristle brush.
Care must be taken to avoid damage
to the sprinklers before, during, and
after installation. Sprinklers damaged
by dropping, striking, wrench twist/
slippage, or the like, must be replaced.
Also, replace any sprinkler that has a
cracked bulb or that has lost liquid from
its bulb. (Ref. Installation Section).
The owner is responsible for the
inspection, testing, and maintenance of
their fire protection system and devices
in compliance with this document, as
well as with the applicable standards
of the National Fire Protection Asso-
ciation (e.g., NFPA 25), in addition to
the standards of any other authorities
having jurisdiction. Contact the install-
ing contractor or sprinkler manufac-
turer regarding any questions.
Automatic sprinkler systems are rec-
ommended to be inspected, tested,
and maintained by a qualified Inspec-
tion Service in accordance with local
requirements and/or national codes.
Care must be exercised to avoid
damage to the sprinklers before,
during, and after installation. Sprin-
klers damaged by dropping, striking,
wrench twist/slippage, or the like, must
be replaced. Also, replace any sprin-
kler that has a cracked bulb or that has
lost liquid from its bulb. (Ref. Installa-
tion Section).
Initial and frequent visual inspections of
random samples are recommended for
corrosion-resistant sprinklers to verify
the integrity of the corrosion-resistant
material of construction. Thereafter,
annual inspections per NFPA 25 should
suffice.lnspections of corrosion-resis-
tant sprinklers are recommended at
close range, instead of from the floor
level per NFPA. Inspection at close
range can better determine the exact
sprinkler condition and the long-term
integrity of the corrosion-resistant
material, which can be affected by the
corrosive conditions present.
TFPI7I
Page 10 of 10
P/N 57— XXX - X - XXX
SIN ] - SPRINKLER
FINISH
1 NATURAL BRASS
- POLY-STAINLESS GREY
2 ALUMINUM (RAL9007)1
-
POLYESTER
PURE WHITE
-
POLYESTER (RAL9010)2
SIGNAL WHITE
-
POLYESTER (RAL9003)
JET BLACK
-
POLYESTER (RAL9005)3
7 LEAD COATED
330 2.8K UPRIGHT (1/2 in. NPT) TY1131
331 2.8K PENDENT (1/2 in. NPT) TY1231
340 4.2K UPRIGHT (1/2 in. NPT) TY2131
341 4.2K PENDENT (1/2 in. NPT) TY2231
370 5.6K UPRIGHT (1/2 in. NPT) TY3131
371 5.6K PENDENT (1/2 in. NPT) TY3231
390 8.0K UPRIGHT (3/4 in. NPT) TY4131
391 8.0K PENDENT (3/4 in. NPT) TY4231
360 8.0K UPRIGHT (1/2 in. NPT) 1Y4831
361 8.0K PENDENT (1/2 in. NPT) TY4931
TEMPERATURE
RATINGS
135 135-F (57-C)
155 1 155°F(68°C)
175 175°F(79°C)
200 200°F (93°C)
286 I 286-F (141-C)
9 I CHROME PLATED
NOTES
Available only on TY3131, TV3231, TV4131, and TY4231
Eastern Hemisphere sales Only.
Available in only 2.8K. 4.2K, and 8.0K. 155°F (68°C) and 200°F (93°C); requires longer lead time
to manufacture.
TABLE D
SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS
PART NUMBER SELECTION
Limited
Warranty
For warranty terms and conditions, visit
www.tyco-fire.com.
Ordering
Procedure
Contact your local distributor for
availability. When placing an order,
indicate the full product name and Part
Number (P/N).
Sprinkler Assemblies with NPT
Thread Connections
Specify: Series TY-FRB (Specify SIN),
(specify K-factor), (specify Pendent or
Upright) Sprinkler (specify) temperature
rating, (specify) finish or coating, P/N
(specify from Table D)
Recessed Escutcheon
Specify: Style (10, 20, 30, or 40)
Recessed Escutcheon with (specify*)
finish, P/N (specify*)
Refer to Technical Data Sheet TFP770
Sprinkler Wrench
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387
Specify: W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001
1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 C 2018 Johnson Controls. All rights reserved. All specific olions and other information Shown were current as 01 document revision dots and are subject to change without notice. Johnson
NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are rrglsl,rnu I,odomorkn 11 National Fire Plotnulion As,00loliolr: Controls TEFLON no roninln,nd Iredneadl OIOAPONI