Loading...
HomeMy WebLinkAbout2641 GATEWAY RD; 101; FPC2020-0195; Permitbty. of PERMIT REPORT Carlsbad Print Date: 05/12/2021 Job Address: 2641 GATEWAY RD, # 101, CARLSBAD, CA 92009-1754 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2131912500 Track #: Valuation: $95,008.96 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check U: Project Title: Description: PANDA EXPRESS -SPRINKLER MONITORING TI Applicant: JJJ ENTERPRISES INC DANTE GOMEZ 115 MARKET PL ESCONDIDO, CA 92029-1353-SAN DIEGO (760) 466-2707 Permit No: FPC2020-0195 Status: Closed - Finaled Applied: 11/16/2020 Issued: 11/24/2020 Finaled Close Out: 05/12/2021 Inspector: Final Inspection: FPContractor: THE STEINHILBER CORPORATION 533 S VINEWOOD ST ESCONDIDO, CA 92029-1924 (760) 747-3050 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 I Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Ifloplop EHcTEpplqoEa FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS FIRE ALARM PRODUCT DATA SUBMITTAL PANDA EXPRESS CHINESE KITCHEN 2641 GATEWAY RD CARLSBAD, CA 92009 D M p.c o M 0 0 0 0 0 0 @ D M PA LAP MS low Zone Expansion Modules FEATURES Provides Class B zones for burglary and fire Compatible with DMP panels that allow zone expansion Suitable for mounting near protection devices Connect devices using four-wire bus Easily mount attractive cases on wall or three-gang box Compatible with all panel zone types Easy connection to four-wire keypad or LX-BusTM Proven design ensures stability and performance Data LED on zone expander indicates good panel communication Durable and attractive plastic or metal housing Low current draw Can be powered from panel or auxiliary power supply Expansion using network communicators DMP.COM 0 0 0 0 0 0 @DMPALARMS USE ON THE DMP LX-BUS The modules can be used on the L>:-Bus of DMP panels. The modules connect to the four-wire bus and use only one zone address. To assign an additional zone expander, use the next available zone address. CONNECT TO KEYPAD BUS You can also use the modules as an addressed device on the keypad data bus of DMP control panels. Simply set the module to ar available keypad address and connect the wiring to the appropriate screw terminals. SIMPLE ADDRESSING Address the 711S, 714, 714-8, 714-16, 75, 715-8 and 715-16 modules by setting two onboard rotary switches with a small screwdriver. The 712-8 uses slide dip switches. EASY INSTALLATION Zone expansion modules are mourned in a decorative plastic housing suitable for installing outside the panel enclosure, such as on walls or single-gang boxes. After all wiring connections are made, the covers go on to form tight-fitting protection against incidental contact or tampering. 714-8, 714-16, 715-8 and 715-'6 Zone Expanders are housed in a rugged, 20-gauge, cold-rolled steel enclosure. You may also mount the 708 and 710 modules inside a DMP enclosure using the three-hole configuration and the provided standoffs. The 712-8 only mounts using the three-hole configuration and provided standoffs. ZONE PROGRAMMING Program the zone on the modules with any of the panels available zone types for use in burglary applications including arming type zones when used with keyswitches. The expansion zones are programmable for annunciation on DMP keypads connected to the panel. Each zone can also be individually programmed to report alarms, troubles and restorals to remote DMP SC:5-1R or SCS-VR Receivers. 708 BUS EXTENDER MODULES The 708 Bus Extender Modules allow you to increase the length of wire used to run an LX-Bus or keypad bus by a maximum of 4,000 feet, while providing immurit' to noise or the wires. This model comes as a pair of modules that connect between the panel and LX-Bus or keypad bus devices. Use the 708 modules for applications that include running wire over long distances, through noisy environments or where the bus is bundled with other wires, such as telephone company wire. The 708 extender can be used on all DMP panels. 108 FEATURES Extercls keypad bus or LX-Bus by 4,000 feet with one rai - of modules (iiii&ts to an auxiliary power supply for added rower Lses exsting wire: No need to rjn additional wire Allows twisted pair and/or shielded wire between the 7)8 modules 110 BUS SPLITTER/REPEATER MODULE The 710 Bus Splitter/Repeater Module allows you to expanc the typical LX-Bus or keypad bus installation ooth in the number of devices and the length of the wire used. Each 710 modue provides three bus connections up :0 2,500 feet. When using mu tiple modules, the total distance of all circuits can be an incredible 15,000 feet! - -I - ..i ii 710 As a splitter, the 710 provides superior mechanical wire connecting capability for up to three additional 12 VDC LX- Bus or keypad bus circuits. This makes the 710 module an excellent junction box when terminating multiple LX-Bus/ keypad bus runs at one location. As a repeater, the 710 module can be installed at the end of an LX-Bus or keypad bus circuit to allow an additional circuit to be added, thus increasing the total wire length. 712-8 ZONE EXPANSION MODULE Expand your system at an affordable price! You can connect non-powered burglary devices to DMP panels using the 712-8 module. It is compatible with many intrusion contacts, glassbreak detectors motion detectors and intrusion 'detectors. 712-8 FEATURES Eight gb .inded, addressable burglary zones Set jumper for LX-Bus or keypad bus operation Compatitle with all DMP panels Expand 5.1stems by connecting a second 712-8 Easily address using dip switches Snaps into panel enclosure using three-hole pattern Separate zone 1k End-of-Line resistors included 114-8/714-16 EXPANDERS SALES APP BUILD A SYSTEM 1114/715 ZONE EXPANDERS The 714 contains four Class B burglary zones and is suitable for use with burglary and fire devices that are normally opened or normally closed. Individual zones are supervised with 1 k ohm End-of-Line (EOL) resistors and can be programmed with any burglary or fire zone type. The 715 contains four Class B powered zones and is suitable for use with 12 VDC, two-wire smoke detectors and non-powered fire or burglary devices. Individual zones on the 715 are supervised with a 3.3 k ohm EOL resistor and can be programmed with any burglary or fire zone type. OPTIONAL ACCESSORIES The standard wiring harness can be replaced with the optional 718T Plug-in Screw Terminal. The enclosure can also accommodate the 719T Terminal Boards for the 714 or the 7201 Terminal Boards for the 715, which pass through the wiring of the panel's LX-Bus. 1 k EOL resistors are included with the 719T, and 3.3 k resistors are included with the 720T. 714/715 FEATURES Four protection zones on each module Comes with 12-conductor wire harness Optional 12-position screw terminal 714-8, 714-16, 715-8 AND 715-16 The expanders are housed in a model. 340 locking metal enclosure suitable for mounting in a remote location. Each expander provides screw terminal strips for zone inputs and data bus connections, a two position jumper to designate connection to the keypad bus or the LX-Bus and an LED to indicate communication with the panel. Separate zone EOL resistors are included with each expander. The 714-8 Expander contains eight Class B zones. The 714-16 Expander contains 16 Class B zones. Both are suitable for use with normally open or normally closed burglary and fire devices. Individual zones are supervised with a 1 k ohm EOL resistor and can be programmed as any zone type. The 714-8 hardware level E is compatible with 1k - 4.7k end of line resistors, making takeovers easy. 715-8/715-16 EXPANDERS The 715-8 Expander contains eight Class B powered zones. The 715-16 Expander contains 16 Class B powered zones. Both are suitable for use with 12 VDC two- wire devices, such as smoke detectors or with non-powered fire or burglary devices. Individual zones are supervised with a 3.3 k ohm EOL resistor and can be programmed as any zone type. 714-8, 714-16, 715-8 AND 715-16 FEATURES 8 or 16 protection zones per expander Durable metal enclosure housing with lock and key Individual screw terminals accommodate 14-22-gauge wire for easy connection Suitable for mounting in a remote location 711 DESCRIPTION The 711 Zone Expansion Module connects to the panel's four-wire keypad bus or LX-Bus and is set to an address that determines the reporting zone number. The 711 provides one Class B zone for the connection of detection devices. 711 FEATURES Single-zone expander Rugged screw terminals accommodate 14-22-AWG wire Board fits in Radionics POPIT housing Easy rotary switch addressing 7115 DESCRIPTION The 711S Zone Expansion Module is a flying lead style, single-zone, addressable expansion module that allows yau to increase the number of reporting zones available on XT30/XT50 and XR150/ XR550 Series panels. It's ideal for smaller applications, such as installing in a pull station back-box or even in a recessed contact hole behind the contact. The modules connect to thepanel's four-wire keypad bus or LX-Bus and are set to an address that determines the reporting zone number. The 711S provides one Type A Class B zone. 714N-POE The 714N-POE Network Zone Expander allows you to add four zones to the XR150/XR550 Series panels using IP network capability. Individual zones are compatible with 1 k-10 k resistors, giving a wide variety for takeovers. POE compatibility provides power for the expander and provides 12 V output for powered zones such as PIRs or glassbreaks. Using AES encryption to talk to the panel provides the next level of protection to the expander. ZONE EXPANSION MODULES ZONE EXPANSION MODULE COMPARISON CHART Refer to the chart below for a comparison of the features for each DMP zone expansion module. rModule Address Number Zones :ifli 108 N/A N/A Yes Yes 12 VD( All DMP 110 N/A N/A Yes Yes 12 VD( 112-8 Dip Switch 8 Yes No 12VD( ill Rotary 1 - No Yes 12 VD( illS Rotary 1 - No - No 12 VD( 714 Rotary 4 (lass B No Yes 12 VD( XI Series and OR Series 114-8 Rotary 8 (lass B No Metal Enclosure 12 VD( 114-16 Rotary 16 Class B No Metal Enclosure 12 VD( 115 Rotary 4 (lass B No Yes 12 VD( 115-8 Rotary 8 (lass B No Metal Enclosure 12 VD( 715-16 Rotary 16 (lass B - No Metal Enclosure 12 VD( 714N-POE 4 No Yes 12 VD( or POE OR Series 108 (Non-UL) Bus Extender Module 714/115 Zone Expansion Module Operating Voltage 8.8 to 15.0 VD( Operating Voltage 8.8 to 15.0 VD( Operating Current 20 mA per pair Operating Current Dimensions 4.5W 2.15' H x 1.75 D 114 Average 1 mA + 1.6 mA per zone Maximum Distance 4,000 feet between the Alarm 1 mA + 2 mA per zone two 108 modules 115 Average 1 mA + 4 mA per zone + 0.1 710 Bus Splitter/Repeater Module per 2-wire smoke Operating Voltage 8.8 to 15.0 VDC Alarm 7 mA + 58 mA per shorted zone + 0.1 Operating Current 30 mA per 2-wire smoke + 30 mA per smoke in alarm Dimensions 4.5W 2.15" H 1.15" D Dimensions 4.5W x 2.15" H x 1.15" D Distance 2,500 feet (one module), 714-8, 714-16,115-8 and 15,000 feet maximum 115-16 Zone Expansion 111 Zone Expansion Module Operating Voltage 8.8 to 15.0 VDC Operating Voltage 8.8 to 15.0 VDC Operating Current Operating Current 114-8/16 Average 11 mA + 1.6 mA per active zone Average 20 mA + 1.6 mA per zone Alarm 11 mA + 2 mA per zone in alarm Alarm 20 mA + 2 mA per zone Zone Voltage 5 VDC 0.6 mA across EOI.) 115-8/16 Dimensions 4.5W x 2.15" H 1.75" D Average 20 mA +4 mA per zone + 0.1 per 2-wire smoke 7115 Zone Expansion Module Alarm 20 mA + 58 mA per shorted zone 0.1 Operating Voltage 8.8 to 15.0 VD( per 2-wire smoke 30 mA per smoke in Operating Current alarm Standby 4.2 mA Enclosure 20-gauge cold-rolled steel Alarm 4.7 mA Dimensions 12.5UW x 11.5" H x 3.5'D Zone Voltage 5 VD(, max 2 mA 114-8116 Color Gray Dimensions 125" W x 2.15" H 115-8/-16 Color Red 712-8 Zone Expansion Module 114N-POE Netwcrk Zone Expansion Module Operating Voltage 8.8 to 15.0 VD( Primary Power 8.5 VD( to 28.5 VDC Current Draw 17 mA + 1.6 mA per active zone Current Draw 11 mA 2 mA per zone in alarm Standby 1.5 mA at 12 VD( Dimensions 4.5" H x 2.5" W Alarm 1.5 mA at 12 VD( Output Voltage(P)E) 12 VDC Max. Power Draw 12.95W Available Output :urnt 150 mA Zone Volage 5 VDC, max 2 mA Dimensions 4.5W x 2.15" H x 1.15 D Certifications Refer to the appropriate panel programming and installation guides for specific compliance listings for installation and programming requirements necessary to meet a particular approval. California State Fire Marshall (CSFM) New York City (FDNY COA #6161) (111,114, 715 only) Underwriters Laboratories (UL) listed For additional information go to DMP.Com/Compliance. 800-641-42821 DMP.com 2500 N. Partnership Blvd, Springfield, NO 65803 Designed, engineered & manufactured in Springfield, MO using U.S. & global components LIMITED WARRANTY. DMP warrants that the products manufactured by DMP and described herein shall be free from defects of manufacture, labeling, and packaging bra period of three (3) years from the invoice date to the original Buyer, provided that representative samples of the defective products are returned to DMP for inspection To read theTull DMP Limited Warranty, go to DMP.comlWarranty or check the DMP Price List or Catalog. © 2020 Digital Monitoring Products, Inc. I LT-0232 120153 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7167-1157:0127 Page 1 of 2 CATEGORY: 7167 -- CONTROL UNIT (HOUSEHOLD) LISTEE: Digital Monitoring Products, lnc.2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Amy Bade (417) 831-9362 Fax (417) 447-9698 Email: abade@dmp.com DESIGN: Models XR100 and XRSOO combination household fire and burglary alarm control units. Local, remote station (PPU), proprietary (PPU), and central station (PPU) services. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: XR500, XR500N, XR500E, XR100, XR100N; Main Board 349, 350, 350A, 352P, 352X; Enclosure 341; Battery Enclosure 630F, 690, 690F, 693, 790, 790F, 791, 793; Supervised LCD Keypads 7060, 7060A, 7063, 7063A, 7064, 7070, 7070A; LCD Keypads 7073, 7073A, 7074, 7760, 7160, 7160A; LCD Keypads 7163, 7163A, 7170, 7170A, 7173, 7173A; LCD Keypads 7560, 7560A, 7563, 7563A, 7570, 7570A, 7573, 7573A; LCD Keypads 7872, 7873; Touch Screen Keypads 325; Transformer Bracket 322, 327, 323; Transformer Adaptor 481, 462N, 462P, 462FM, 472; Interface Card 461; Interface Adaptor 714, 714-8, 714-16: 715,711, 711E; Zone Expanders 715-8, 715-16, 725 Zone Expanders Output Expander Annunciator Module 860; Relay Module 865, 866, 867; Indicating Modules 869; Initiating Module 893A; Dual Phone Line Module 733, 734, 734N; Wiegand Interface 710, 710F; Bus Splitter 303; Reset/Silence Switch COM, iCOM-E; Internet Alarm Router 1100X, 1100XH, 1100XI; RF (Wireless) Receiver 1 100R; Wireless Repeater 1103; Wireless Transmitter* 463C, 463G, CellComRT; Digital Cellular Communicator *Rev 09 04 13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division Lstinc No. 7167-1157:0127 Page .2 o12 9060, 9063, 9862, 9863; Wireless Keypads 1135; Wireless Sirer RATING: 120 VAC, 0.5 A 60 Hz primary, 12 VDC secondary INSTALLATION: In accodancE with listee's printed installation instrucions, app icable codes & crdinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as con-b iation household fire anc burglary ala-rn control units for use wh separately listed e.ectricalI' compatible initiating and indicatiig devices. Fefer to I stee's Irstalfation Instructions Manual for details. These control L:iits can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: 1. The Fire Alarm Verification Feature delay of fire alarm signal), the maximum Retard 'Res etiRestart period shall not exceed 30 seconds. 2. Burclary and other non-fire functions were not examined. Rev.09-04-13 gt This listing is eased ipon technical data submitied by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or cther data but does not make an independent verification of any claims. This listing is not an endorsemen: or recommendation of the item listed. This Iistiig should rot be used to verify correct operatioial requiremen:s or installation criteria. Refer to listee's data sheet, installaion instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID cASTfLLO,, ME., F.P.E. Fire Engineering Division DMP.COM 0 0 0 0 0 0 @DMPALARMS Compatible with XR150/XR55011 Series System events display in plain English Keyswitch enables single-button operation Flush or surface mount Full operation with authorized code 630F DMP Fire Command Keypad FEATURES Simple harness connection to 4-wire keypad bus At-a-glance system status Powered from panel or auxiliary power supply Optional backboxes for conduit or wall mount applications Attractive non-obtrusive designs Built-in diagnostics Two-button Panic keys AC Power, Trouble, Alarm LED 630F FIRE COMMAND KEYPAD 630F REMOTE ANNUNCIATOR The 630F Fire Command Center offers a 32-character full text LCD readout that displays system events and menu prompts, making it efficient and easy to use. The backbox and tim f-ame provide an attractive installaticn. The keypad can either be flush-mounted or surface-mounted. 630F Keypad SINGLE-BUTTON OPERATION The 630F Fre Command Cen:er has a factory-installed keyswitch that enables the four function buttons - Alarm Silence, System Reset, System Test, and Fire Drill. TI-c user can also access these four functions and many more through the User Menu by enterirg a valid user code. BUILT-IN DIAGNOSTICS An internal diagnostics program lets installers and service technicians test the operation of the keypad at any time without disabling the system. SUPERVISED AND UNSUPERVISED OPERATION The 630F keypad can be programmed for supervised or unsupervised opera- tion on the keypad data bus, increasing the overall number of keypads you can install to provide maximum flexibility. When supervised, the keypad occupies its own address. Unsupervised operation allows you to install multiple keypads on the bus with the same address. STATUS LEDS The Green Power LED turns on when primary AC or DC power to the panel is at an acceptable level and flashes when its battery is low or missing. A Yellow Trouble LED turns on when either the panel has failed to communicate with the monitoring center receiver or when phone line 1 or 2 is in a bad condition. Specifications Operating Voltage 8.5 to 15 VD( Current Draw 63mAstandby - 92 mA maximum Trim Frame Dimensions 10.4W x 7.0 H x IT D Backbox Dimensions 8.750 W 6.375' H "2.5" D Panel Compatibility XR150 and XR550 Series Panels Keypad Accessories 635 1.75" 630F Alternate Surface Mount Backbox 635F 2.5" 630F Flush Mount Replacement Backbox 300 4-wire Replacement Harness Certifications California State Fire Marshal (CSFM) New York City (FDNY (OA #6167) FCC Part 15 Underwriters laboratories (UL) Listed ANSI/UI 864 Control Units for Fire Protective Signaling ANSI/UL 985 Household Fire Warning ULC-5559-04 Equipment for Fire Signal Receiving Centers and Systems For additional information, Go to DMP.com/Compliance. 800-641-4282 I DMP.com 2500 N. Partnership Blvd, Springfield, NO 65803 Designed, engineered B manufactured in Springfield, NO using U.S. & global components LIMITED WARRANTY: DMP warrants that the products manufactured by DMP and described herein shall be tree from detects of manufacture, labeling, and packaging for period of three (3) years from the invoice date to the original Buyer, provided that representative samples of the detective products are returned to DMP for inspection To road the full DMP Limited Warranty, go to DMPcomPA'arranty or check the DMP Price List or Catalog. 102019 Digital Monitoring Products, Inc. I LT-0318 119271 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7167-1157:0127 Page 1 of 2 CATEGORY: 7167 -- CONTROL UNIT (HOUSEHOLD) LISTEE: Digital Monitoring Products, lnc.2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Amy Bade (417) 831-9362 Fax (417) 447-9698 Email: abade@dmp.com DESIGN: Models XR100 and XR500 combination household fire and burglary alarm control units. Local, remote station (PPU), proprietary (PPU), and central station (PPU) services. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: XR500, XR500N, XR500E, XR100, XR100N; Main Board 349, 350, 350A, 352P, 352X; Enclosure 341; Battery Enclosure i630F690, 690F, 693, 790, 790F, 791, 793; Supervised LCD Keypads 7060, 7060A, 7063, 7063A, 7064, 7070, 7070A; LCD Keypads 7073, 7073A, 7074, 7760, 7160, 7160A; LCD Keypads 7163, 7163A, 7170, 7170A, 7173, 7173A; LCD Keypads 7560, 7560A, 7563, 7563A, 7570, 7570A, 7573, 7573A; LCD Keypads 7872, 7873; Touch Screen Keypads 325; Transformer Bracket 322, 327, 323; Transformer Adaptor 481, 462N, 462P, 462FM, 472; Interface Card 461; Interface Adaptor 714, 714-8, 714-16; 715, 711, 711E; Zone Expanders: 715-8, 715-16, 725; Zone Expanders Output Expander Annunciator Module 860; Relay Module 865, 866, 867; Indicating Modules 869; Initiating Module 893A; Dual Phone Line Module 733, 734, 734N; Wiegand Interface 710, 710F; Bus Splitter 303; Reset/Silence Switch COM, iCOM-E; Internet Alarm Router 1100X, 1100XH, 1100XI; RF (Wireless) Receiver 1100R; Wireless Repeater 1103; Wireless Transmitter* 463C, 4630, CellComRT; Digital Cellular Communicator *Rev 09 04 13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing No. 7167-1157 0127 Page 2 of 2 9060, 9063, 9862, 9863; Wireless Keypads 1135; Wireless Siren RATING: 120 VAC, 0.5 A. 60 Hz prinary, 12 VDC secondary IISTALLATION: In acrdance with listees printed installation instructions, applicable codes & ordinances and in a manne- acceptable to the authority having jurisdiction. MARKING: Listes name, model nunber, electrical rating and UL label. APPROVAL: Listed as combination hojsehold fire and burglary alarm control units for use with separately listec electricall compatbie initiating and indicating devices. Refer to listees Installation Instructions Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: 1. The Fire Alarm Verilicaton Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Burglary and other non-lire functions were not examined. Rev.09-04-1 3 gt This 1sting is based un technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data out does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID cASTfLLO,, ME., F.P.E. Fire Engineering Division Exceder Strobe, Horn Strobe, and Horn Notification Appliances FITON Powering Business Worldwide Description The Wheelock Exceder Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock Exceder Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock Exceder Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the LIMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The LIMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Technical Data TD450049EN Effective November 2016 Features Sleek modern aesthetics Finger slide switches Voltage test points Multiple voltages 3 Audible settings 90, 95, 99 dB Industry leading-8 candela settings cn device Wall: 15/1575/30/75/95/110/13E/185 Ceiling: 15/30/60175/95/115/150/177 Universal mouting base Ceiling and wall Mounts to 5 backbox types: 1 gang, 2 gang, C' square, 3.5" octal. & 4" octal. (100mm for international customers) Universal mounting base Contact cover - Common base for wall and ceiling with 5 mounting options Voltage test points for quick troubleshcoting and easy spot checking (wall models only) , 2 EATON www.eaton.com HN Series HS Series ST Series Environmentally friendly Low current draw Up to 9 models now in 1 appliance draw(D 2/24VDC on a single appliance Easy to remember model numbers tIn Patented Note: Please read these specifications and associated installation instruc- cr-s, before using, specifying, or install ng this produt. Visit Eaton.com/ nassnotification for current installation instructions. General Notes Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range All candela ratings represent minimum effec:ve strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) UL 464(85% UL 1970. Series Exceder horns are under UL Standarc 464 for audible signal appliances (Indoor use on,y). Compatibility and requirements Synchronize using the Wheelock® Sync Modules or panels with built-in Wheelock® Paten:ed Sync Protocol Compatible with UL "Regulated Voltage" us ng filtered VDC or unfiltered VRMS input voltage Strobes produce I flash per second over the "Regulated Voltage" range Compliance UL 1971, UL 464, ULC, CSFM, FM ADNNFPA/ANSI/OSHA RoHS Model Legend HN = Horn -- R = Red ST = Strobe A = Agent Lettering (strobes only) HS = Horn Strobe AL = Alert Lettering (strobes only( C = Ceiling Mount N = No Lettering (strobes only) W = White Example 1: STFIC = Strobe, Red, Ceiling Mount Example 2: HSR = Horn Strobe, Red, Wall Mount Example 3: HSW = Horn Strobe, White, Wall Mount Example 4: STVV-AL = Strobe, White, Wall Mount, Alert Lettering Example: HSR HN Series HS Series ST Series Table 1. Strobe Ratings per UL Standard 1971 UL Max Current® Technical Data TD450049EN Effective November 2016 4VUI24IVVK 12VDC Regulated Voltage Model Range VDC 15 15175 30 60 75 95 110 115 135 150 177 185 15 15175 ST 8.0-33.0 0.057 0.070 0.085 - 0.135 0.163 0.182 - 0.205 - - 0.253 0.110 0.140 SIC 8.0-33.0 0.061 - 0.085 0.103 0.135 0.163 - 0.182 - 0.205 0.253 - 0.110 - Table 2. Horn Strobe Ratings per UL 1971 &Anechoic at 24 VDC UL Max Current® at Anechoic 99 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.082 0.095 0.102 - 0.148 0.176 0.197 - 0.242 - - 0.282 0.125 0.159 HSC 8.0-33.0 0.082 - 0.102 0.141 0.148 0.176 - 0.197 - 0.242 0.282 - 0.125 - UL Max Current® at Anechoic _95_dBA 24V0C 12VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 - 0.139 0.163 0.186 - 0.230 - - 0.282 0.122 0.153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163 - 0.186 - 0.230 0.272 - 0.122 - UL Max Current® at Anechoic 90 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 - 0.226 - - 0.267 0.120 0.148 HSC 8.0-33.0 0.065 - 0.084 0.120 0.136 0.157 - 0.184 - 0.226 0.267 - 0.120 - ® UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VOC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Table 3. Horn Ratings per UL Anechoic Regulated Voltage Model Range VDC 99 dB 95 dB HN 16-33.0 0.064 0.044 90 dE 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 Table 4. Specification & Ordering Information Sync wl DSM or Wheelock Power Model Strobe Candela Supplies Horn Strobes 12/24 Mounting VDC® Options HSR 15/1575/30/75/95/110/135/185 X X UMB® HSW 15/1575/30/75/95/110/135/185 X X UMB® HSRC 15/30/60/75/95/115/150/177 X X UMB® HSWC 15/30/60/75/95/115/150/177 X X UMB® Strobes SIR 15/1575/30/75/95/110/135/185 X X UMB0 SIW 15/1575/30/75/95/110/135/185 X X LIMB® STRC 15/30/60/75/95/115/150/177 X X UMB® STWC 15/30/60/75/95/115/150/177 X X LIMBO Horn HNR X X LIMB® HNW X X UMB® HNRC X X UMB® HNWC X X UMB® ® 12 voc models feature 15 & 15/75 settings © UMB = Universal Mounting Base EATON www.eaton.com 3 Technical Data 1D450049EN HN Series Effective November 2016 HS Series ST Series Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series SVisual Strobe appliances and Series - HN Audible appliances or approved equals. The Series HS and ST Strobes shall ba listed for UL Stancard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be U. Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliancas shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged LexanO lens The Series shall be of low current design. Where multi- candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 1, 15175, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mcJnt. The selector switch fo selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela 'JL Standard 1971 Listing with 75 candela on-axis is required (e.g., ADA compliance). Appliances with candela settilgs shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have E. choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall inccrporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-in,h octzl or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity cnecking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5 24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Syrc Modules, Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out cf synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert tc a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wall Appliances: UL Standard 1971, UL Standard 464, California State Firs Marshal (CSFM), LLC, F A RoHS Ceiling Appliances: UL Standard 1971, UL Standard 464, California State Fire IV arshal (CSFM) ULC FM, RoHS Note: Due to continuous development of our products, specifications and otfeings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Eaton standard terms and conditions. (Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3YEAR WARRANTY Eaton 1000 Eaton Bojlevard Cleveland, OH 44122 United States - Eatoncom Eaton Life safety & mass notification solutions 273 Branchpor Ave. Long Branch, NJ 07740 Eaton.com/ma ssnotification © 2016 Eaton E UrN All Rights Reserved Printed in USA Publication No. TD450049EN Powering Business Worldwide November 2018 ) Eaton is a registered trademark. All other trademarks are property of their respective owners. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL __ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785-.0168 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock lnc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conovercooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be added for ceiling models and/or a '-NR' may be added for non-resettable models. For non -NR models and optional '5' for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. Rev. 9-24-09 In, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed ' the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division