HomeMy WebLinkAbout2628 GATEWAY RD; 135; FPC2019-0142; PermitPERMIT REPORT (ityof Carlsbad Print Date: 10/18/2021 Permit No: FPC2019-0142 Job Address: 2628 GATEWAY RD, # 135, CARLSBAD, CA 92009-1777 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel If: 2132621900 Track If: Applied: 06/25/2019 Valuation: $135,605.00 Lot If: Issued: 07/09/2019 Occupancy Group: Project If: Finaled Close Out: 11/21/2019 #of Dwelling Units: Plan If: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check If: Inspector: Plan Check If: Final Inspection: Project Title: Description: EBULLITION BREW WORKS -SPRINKLER TI (21 HEADS) FPContractor: BRIAN SULLIVAN 1975 SPANISH OAK WAY VISTA, CA 92081-7383 (760) 716-9226 FEE AMOUNT FIRE NFPA 13 or 13R System 7- 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov A2c2-ovt--Oi49 tqco® Worldwide I www.tyco-fire.com Contacts Series TYFRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in tight or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 in. (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 in. (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a tire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY313.... Upright 5.6K, 1/2 in. NPT TY323. . . .Pendent 5.6K, 1/2 in. NP1 Technical Data Approvals Refer to Table A Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Underwriters Lai des, Inc. (UL). Discharge Coefficient K=5.6 GPM/pS1½ (80,6 LPM/b&'2) Temperature Rating Refer to Table A Finishes Sprinkler Refer to Table B Recessed Escutcheon: White Coated, Black Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Seating Assembly . . . Stainless Steel wITEFLON Bulb...............................Glass Compression Screw .................Bronze Deflector ..........................Bronze AUGUST 2018 m Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. TFPI72 TFPI72 Page 2 of 4 Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* \\ _ (11,1 mm) 2 2" I 1-3/8 ________ 2" MAKE-IN ______ I NOMINAL 50,8 mm) _____ ______ I 7/16" ______ 3 ' (50,8 mm) I (34,9 mm) RENCH FLATS 1/2 NPT** DEFLECTOR* 2-7/8" (73,0 mm) 01k I CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) and 3/32 in. (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprinkler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 Nm). Step C. After ceiling installation and finishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. / WRENCH RECESS / (USE ONLY FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Uptight (TY313) and Pendent (1Y323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a'feather duster; otherwise, non- operation inthe event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated,, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have' been exposed to corrosive products'of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care musf be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of 'their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation(e.g., NFPA 25),in addition to the standards of any other authorities having 'jurisdiction. Contact the install- ing'contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. - 2-7/8° DIA. (73,0 mm) - 2-1/4' DIA. FACE OF (57,2 mm) SPRINKLER FITTING _____ _______ FLUSH 3/8±5/16° _______ 5/8° (15,9 mm) (9,5±7,9 mm) ' _______ J - MOUNTING SURFACE ______ _______ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8° (34,9 mm) TY-FRB PLATE 3/4' (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8' 01k (73,0 mm) FACE OF' SPRINKLER - 2-1/4° DIA. FITTING (57,2 mm) (794 fl) ' 'L 1/2(12,7mm) FLUSH !1/ MOUNTING j SURFACE/ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TVFRB PLATE 7/8° (22,2 mm) FIGURES SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON For warranty terms and conditions, visit Limited Warranty Recessed Escutcheon Specify: Style 15 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) www.tyco-fire.com. Refer to Technical Data Sheet TFP770 Sprinkler Wrench Ordering Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Procedure Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pendent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) temperature rating, (specify) finish, P/N (specify,, to Table A). 1 I NATURAL BRASS PURE WHITE (RAL901O)a POLYESTER SIGNAL WHITE (RAL9003) POLYESTER I I JET BLACK (RAL900S) POLYESTER 9 I CHROME PLATED 135 135°F(57°C) 155 155-F (68-C) 175 175-F (79-C) 200 200°F (93°C) 286 286°F (141°C) TFPI72 Page 4 of 4 SPRINKLER FINISH (See Note 7) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED I I OLYESTERC 135°F (57°C) Orange UPRIGHT (1Y313) 155°F (68°C) Red 175°F (79°C) Yellow and 1, 2, 3, 4, 5, 6 5.6 1/2 in. NPT PENDENT (TY323) 200°F (93°C) Green 286°F (141°C) Blue ________________ 135°F (57°C) Orange RECESSED PENDENT (TY323) Figures 48 and 5b 1,2,3,4 155°F (68°C) Red 175°F (79°C) Yellow 200-F (93-C) Green Notes: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-54-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Rot. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Installed with Style 15 (1/2 in. NPT) 5/8 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20(1/2 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS P/Na_77XX SIN 370 5.6K UPRIGHT (1/2 in.NPT) TY313 371 5.6K PENDENT (1/2 in.NPT) TY323 Notes: a. Use suffix "I" for ISO 7-1 connection; for example, 77-370-4-175-I -xxx 71 SPRINKLER TEMPERATURE FINISH RATINGS Notes: a. Eastern Hemisphere sales only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 1400 Pennbrook Parkway, Lansdale, PA 19446 Telephone +1-215-362-0700 0 2015 John,on cont,ol,. AD nght. All p.oW,voIfon nd oth. info,,notiw &Eown ww. wv,ent 'I. of dom,,o,d ,e,tNloo dot. .nd orG ,oblool to chango withoot ,tIco. NATiONAl. FIRE PROTECTION ASSOCIATION of NFPA t,a rPRiAlood IrodAookROf NOIIAAU AoNAAo,,AA.o&lIo5 TEFLON N. roNAtood NAd000,00fll,,Pwt Johnson Controls tqca Worldwide I www.tyco-flre.com Contacts Series TY-B, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The TYCO Series TV-B, 5.6 K-factor, Upright (TY315) and Pendent (1Y325) Sprinklers described in this data sheet are standard response, standard cov- erage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com- mercial occupancies such as banks, hotels, shopping malls, factories, refin- eries, and chemical plants. The recessed version of the Series TV-B Pendent Sprinkler, where applica- ble, Is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 in. (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 in. (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TV-B Sprinklers are described in Tech- nical Data Sheet TFP352. Sprinkler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Refer to Technical Data Sheet 7-FP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The Series TY-B Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Numbers (SINs) TY315 .. ., Upright 5.6K, 1/2 in. NPT., TV325 .... Pendent 5.6K, 1/2 in. NPT Technical Data Approvals Refer to Table A Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Underwriters Laborato-ries, Inc. (UL). Discharge Coefficient K = 5.6 GPM/ps1½ (80,6 LPM/bar½) Temperature Ratings Refer to Table A Finishes Sprinkler Refer to Table B Recessed Escutcheon: White Coated, Black Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Seating Assembly . . . Stainless Steel w/TEFLON Bulb...............................Glass Compression Screw .................Bronze Deflector ..........................Bronze AUGUST 2018 Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TV-B, 5.6 K-factor, Upright (TY315) and Pendent (TV325) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of the FM Loss Preven- tion Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. TFPIS2 TFPI52 Page 2 of 4 Components: *.Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector, can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2° 7/16 (11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON _v j°!' * 6 _______ t 7/16° ______ ______ I NOMINAL : I (11,1 mm) ______ MAKE-IN _____ (50,8 mm) _____ 2° I 1-3/8° 3 (50,8 mm) I (34,9 mm) WF 1 1_J_ H _________ Fl 1/2° NPT** DEFLECTOR* 2-7/8° (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TV-B UPRIGHT (TY315) AND PENDENT (TY325) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE WRENCH RECESS (USE ONLY 60 /Z/ END 'A") FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH Installation The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F(57°C)to 3/32 in. (2,4 mm) for the 360° F (182°C) tempera- ture ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N.m). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the escutch- eon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TV-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position; install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the WType 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N.m). Recessed Pendent Sprinklers The Series TV-B Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the, sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply th' p W-Type 7 Recessed Sprinkler Wrench- to the sprinkler wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 190 N.m). Step C. After the ceiling is installed or the finish coat is applied, slide -on the Style 15 or Style 20 Closure over the Series TV-B Sprinkler and push the Closure over the Mounting Plate until its flange contacts the ceiling. TFPIS2 Page 3 of 4 Care and Maintenance The TYCO Series TV-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) Thereafter, annual inspections per NFPA 25 are required; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinklers are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TV-B Upright or Pendent (specify) Sprinkler, SIN (specify), K=5.6, Standard Response, (specify) temperature rating, (specify) finish, P/N (specify, refer to Table B) Recessed Escutcheon Specify: Style 15 Recessed Escutch- eon with (specify") finish, P/N (specify") Specify: Style 20 Recessed Escutch- eon with (specify) finish, P/N (specify) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 2-7/8' DIA. - (73,0 mm) — 2-1/4" 01k FACE OF (57,2 mm) SPRINKLER FITTING 5/8" (15,9 mm) FLUSH 3/8±5/16" I / (9,5±7,9 mm) 117 / t / MOUNNG / 1/8° SURFACE J I \_(3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TV-B PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TV-B RECESSED PENDENT SPRINKLER ASSEMBLY (TY325) WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8° 01k (73,0 mm) FACE OF SPRINKLER — 2-1/4' DIA. FITTING (57,2 mm) 5/16±1/4° 1/2' (12,7 mm) (7,9±6,4 mm) / FLUSH MOUNTING / 8' J SURFACE// \ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TV-B PLATE 7/8° (22,2 mm) FIGURE 5 SERIES TV-B RECESSED PENDENT SPRINKLER ASSEMBLY (TY325) WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 1 NATURAL BRASS - PURE WHITE (RAL9010)°° POLYESTER SIGNAL WHITE (RAL9003) POLYESTER JET BLACK (RAL9005) POLYSTER 9 CHROME PLATED 570 1 5.6K UPRIGHT (1/2 in. NPT) I TY315 571 1 5.6K PENDENT (1/2 in. NPT) I TY325 TFPI52 Page 4 of 4 K SPRINKLER TYPE TEMPERATURE RATING BULB LIQUID COLOR SPRINKLER FINISH (7) NATURAL BRASS CHROME PLATED POLYESTER** 135°F (57°C) Orange UPRIGHT (TY315) 155°F (68°C) Red 175°F(79°C) Yellow 5.6 and PENDENT (TY325) Figure 1 123,45,6, 200°F (93°C) Green 286-F (141-C) Blue 360°F (182°C) 1/2 in. Mauve NPT 135°F (57°C) Orange 155°F (68°C) Red RECESSED PENDENT (TY325)* 1, 2, 3, 4, 175°F (79°C) Yellow 200°F (93°C) Green Figures 4 and 5 286-F (141-C) Blue 1,2 Notes: Listed by Underwriters Laboratories, Inc. (UL) Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) Approved by FM Global (FM Approvals) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03) VdS Approved (For details contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444 / Fax 31-53-428-3377) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05) Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Installed with Style 15(1/2 in. NPT) 5/8 in. Total Adjustment Recessed Escutcheon, as applicable Frame and deflector only N/A - Not Applicable TABLE A SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS P/N*77_XXX_X_ SIN xxx SPRINKLER TEMPERATURE I I FINISH RATINGS * Use suffix "I" for ISO 7-1 connection; for example, 77-570-4-175-I Eastern Hemisphere sales only OPEN indicates sprinkler assembly without Glass Bulb, Button, and Sealing Assembly 135 135°F(57°C) 155 155-F (68-q 175 175-F (79-C) 200 200°F (93°C) 286 286°F (141°C) 360 360°F(182°C) 000 OPEN*** TABLE B SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS - PART NUMBER SELECTION 1400 Pennbrook Parkway, Lansdale, PA 19448 I Telephone +1-215-382-0700 02518 Jot,n.on Controfa At) flght. ,00n,v.d. All apooltinotlano and oU,.a into.,natjan ohowo, wono o*,n'.nt on of daaa,nnat roatolo,, dnAe and ors nobjootta nba,,ge without notice. NATIONAL FIRE PROTECTION ASSOCIATION and NFPA at MOstwedNAJo,no,I,00tNAJanot R,oP,otooljonA000dnlj*FI TEFLON ,o8iAo,od pndooAotnoP.nt Alt, Johnson Controls FireLockTM V36, K56 ModeIsSIt3605 V3606 / uctaul.c' 40.60 Dry Type Pendents Standard and Quick Response Flush Sleeve and Skirt Plain Barrel Intermediate Extended Recessed 1.0 PRODUCT DESCRIPTION Models: V3606 and V3605 Style: Pendent, Recessed Pendent or Intermediate Level Pendent Nominal Orifice Size: ½/13 mm K-Factor: 5.6 Imp./8.1 S.l.' Nominal Thread Size: 1' NPT/25 mm BSPT Max. Working Pressure: 175 psi/1207 kPa/12 bar Factory Hydrostatic Test: 100% @ 500 psi/3447 kPa/34 bar Mm. Operating Pressure: 7ps1148 kPal.5 bar Temperature Rating: See table in section 2.0 I For K-Factor when pressure is measured in bar, multiply S.I. units by 10.0. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com 40.60 3123 Rev K Updated 02/2019 02019 Victaulic Company. All rights reserved. tauiicr 1 victaulic.com 2.0 CERTIFICATION/LISTINGS C@. zS® um Model V3605 V3605 V3606 V3606 APPROVALSILISTINGS Orifice Size (inches) ½ - ½ ½ Orifice Size (mm) 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 Nominal K Factor 5.1.2 8.1 8.1 8.1 8.1 Response - - Standard Standard Quick Quick DefiectorType Pendent Recessed Pendent Pendent Recessed Pendent Approved Temperature Ratings F°/C° - 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C cULus 200eF/93C 200°F/93°C 200°F193°C 200°F/93°C - - 286°F/141°C 286°F/141°C 286°F1141°C 286°F/141°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C FM 155°F/68°C 155 I °F 68°C 155°F/68°C I' 155°F 68°C 200°F/93°C 200 9 0C 200°F/93°C • 286°F/141°C 286°F/141°C CCC -155°F168°C I 155°F168°C None -None 2 For K.Factor when pressure is measured in Bar, multiply S.I. units by 10. NOTE Listings and approval as of printing. Temperatures are listed for all hazards and approved for V3605 and V3606 dry sprinklers up to 48 length. CCCI approved for V3605 dry sprinklers 107 to 1250 mm/4.2 - 49.2 in length. 40.60 3123 Rev K Updated 02/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 2 "It A-c—ta—ulict Exaggerated for clarity victaulic.com 3.0 SPECIFICATIONS - MATERIAL Deflector: Brass or stainless steel Bulb: Glass with glycerin, solution Bulb Nominal Diameter: o Standard: 5:0 mm 0 Quick Response: 3.0 mm' Split Spacer: Stainless steel Load Screw: Brass Pip Cap: Stainless steel Spring Seal Assembly: Teflon T'3 coated Beryllium nickel alloy and stainless steel Frame: Die cast brass Outer Tube: Galvanized steel pipe Inner Tube: Stainless steel Orifice Insert: Stainless steel Escutcheon/Plate: 1010 - 1018 mild steel and stainless steel Torsion Spring: SST Wire Installation Wrench: Model V36 Open End and Recessed Wrenches fit all V36 Series frames. Sprinkler Finishes: U Plain brass O Chrome plated O White painted45 El Flat black painted45 F1 Custom painted4 El VC-2506 3 Teflon is a registered trademark of Dupont Co. Not available on the Intermediate Level Style Pendent. UL Listed for corrosion resistance. 6 UL Listed and FM Approved for corrosion resistance. NOTE Weather resistant escutcheon available upon request. For cabinets and other accessories refer to separate sheet. 40.60 3123 Rev K Updated 02/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 3 -11.04—cta—ulicr victaulic.com 4.0 DIMENSIONS Tee with same outlet size [----- - -fl Tee with same outlet size as sprinkler thread size. : ,._ : i-- as sprinkler thread size. document -- I"NPT document - - . NPT Information, later in this 1W Mi Dia. (Mm. 1W) 1½" Mm Dia. (Mm. 1W) Hole in Ceiling Seeimportant Installation See"Important Installation later in this lnformation j I= Hole in Ceiling I=VJ7 Y47-- 2" Flush I — — Tee with same outlet size - - — -- fl Tee with same outlet size as sprinkler thread size. as sprinkler thread size. See "Important Installation Seeimportant Installation lnformation later in this - - Information, later in this t l document T NPT document (Mm. (Mm. 1W) .1_i v71 3'Dia.— I IntermedIate Level Pendent . Plain Barrel Tee with same outlet size 11T - - 11 Tee with same outlet size ' as sprinkter.thread size. : : ' as sprinkler thread size. Seeimportant Installation -- Information!, later in this -- Information', later In this .1, 1'NPT document I 1NPT document (Min..1 V.") 1½' Mm. Dia. . Hole In Ceiling I 3½'_J J• Seeimportant Installation (Mln.134") Collar 2' Min. Dia. 3WMin. S Max. . HolemnCeiling rwopiece Escutcheon I in. Ceiling Cup L 2W Dia.] Max. Extended Recessed NOTE The "A' dimension of a dry sprinkler, which extends into a freezer from a wet piping system, must take into account the wall or ceiling thickness of the freezer. See IMPORTANT INSTALLATION INFORMATION later in this document. 40.60 3123 Rev K Updated 02/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 4 \J(tt1GIUIiC Twoece Escutcheon 2W Min. 4" Max. Sleeve and Skirt victaulic.com 5.0 PERFORMANCE Contact Victaulic for performance details. 6.0 NOTIFICATIONS WARNING iou 0 • Read and understand all instructions before attempting to install any Victaulic products. Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. 40.60 3123 Rev K Updated 02/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 5 JltauIiC' victaulic.com 7.0 REFERENCE MATERIALS Important Installation Information: For detailed installation instructions, see publication 1-40. No. 1 Victaulic Model V36 Series Dry sprinklers should be installed in accordance with NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler wrench may be used with extreme care for lengths up to approximately 18'. Excessive force may distort the frame thus destroying the unit. No. 2 Dry sprinklers MUST be installed only into the outlet of a cast or malleable iron tee. No. 3 DO NOT install dry sprinklers into any couplings or threaded elbows. In addition, DO NOT install dry sprinklers into any fitting that interferes with thread penetration. NOTE: The end seal of the dry sprinkler MUST NOT bottom out in the fitting. TYPICAL SLEEVE AND SKIRT CONFIGURATION FOR EXAMPLE ONLY HEATED SPACE TWO Wngo4 COLD SPACE NOTE The "A" dimension of a dry sprinkler, which extends into a freezer from a wet piping system, must take into account the wall or ceiling thickness of the freezer. The minimum length of the dry sprinkler should not be less than the lengths specified in the following table, plus the thickness of the freezer's wall or ceiling ("A" = "C" + Refer to the drawing for a representation of the "A" dimension. DO NOT attempt to modify dry sprinklers, since they are manufactured to this specific "A" dimension. The following table is used when the ambient temperature is maintained between 40°F/4°C and 60°F/16°C around the wet piping system. Ambient Temperature Exposed Exposed Minimum Barrel Length to Discharge End of Sprinkler inches/mm 'F 40°F 50°F 60°F oc 4°C 10°C 16°C 40 0 0 0 4 0 0 0 30 0 0 0 -1 0 0 0-- 20 4 0 0 -7 102 0 0 10 8 1 0 -12 203 25 0 0 12 3 0 -18 305 76 0 -10 14 4 1 -23 356 102 25 -20 14 6 3 -29 356 152 76 -30 16 8 4 -34 406 203 102 -40 18 8 4 -40 457 203 102 -50 20 10 6 -46 508 254 152 -60 20 10 6 -51 508 254 152 40.60 3123 Rev K Updated 02/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 6 \/tauIiC .4 I p vietauliccom 7.0 REFERENCE MATERIALS (CONTINUED) Ratings: All glass bulbs are rated for temperatures from -67°F/-550C to those shown in the table below. Temperature Nominal Temperature Maximum Ambient Rating Temperature Allowed Sprinkler Temperature °F °F Classification ' °C °C Glass Bulb Color Ordinary 135°F 100°F Orange 57°C 38°C Ordinary . 155°F 100°F Red 68°C 38°C Intermediate 200°F 150°F Green - 93°C 65°C -- - - Intermediate 286°F 225°F Blue 141°C 107°C Available Wrenches: Model V36 Open End and Recessed Wrenches fit all V36 Series frames. 7.1 REFERENCE MATERIALS 10.65: Victaulic FireLockTM IGS lnstallation•ReadynM Style V9 Sprinkler Coupling 25.14: Victaulic IGS Groove Specifications l-V9: Style V9 Victaulic FireLpckTM IGSTM Installation•ReadvrM Sprinkler Coupling 1-40: Victaulic FirelockiM Automatic Sprinklers Installation and Maintenance Guide User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any prevision of Victaulic Company's standard conditions of safe, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, In grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in POE format on our website at www.victautic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 40.60 3123 Rev K Updated 02/2019 0 2019 Victaulic Company. All rights reserved. victaulic.com \4taulicr r_. FPC20I9-0142 2628 GATEWAY RD #135 EBULLITION BREW WORKS - SPRINKLER TI (21 HEADS) 2132621900 :- 6/25/2019 ____ FPC20I9-0142