Loading...
HomeMy WebLinkAbout2662 GATEWAY RD; 155; FPC2018-0341; Permit4ityof PERMIT REPORT Carlsbad Print Date: 10/18/2021 Permit No: FPC2018-0341 Job Address: 2662 GATEWAY RD, # 155, CARLSBAD, CA 92009 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2132622100 Track U: Applied: 10/16/2018 Valuation: $365,382.56 Lot #: Issued: 10/31/2018 Occupancy Group: Project U: Finaled Close Out: 02/11/2019 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check #: Final Inspection: Project Title: Description: BEVMO -SPRINKLER TI Applicant: FPContractor: CAL-WEST FIRE PROTECTION SPECIALIST CAL-WEST FIRE PROTECTION GONZALO PENA 8361 COMMONWEALTH AVE 8361 COMMONWEALTH AVE BUENA PARK, CA 90621-2525 BUENA PARK, CA 90621-2525 (714) 912-4552 (714) 912-4552 FEE AMOUNT FIRE NFPA 13 or 13R System 7- 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 F 760-602-4665 760-602-8561 f I www.carlsbadca.gov ef ao~ 0,141 Page lof7 DRY PENDENT STANDARD 'i I I(I Is1G® - STANDARD RESPONSE ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. DESCRIPTION Viking Standard Response Dry Pendent Sprinklers are therrnosensitive spray sprin- klers suitable for use in areas subject to freezing. The sprinklers are designed for dry systems and preaction systems where it is necessary to prevent water or conden- sation from entering the drop nipple before sprinkler operation. They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Standard Response Dry Pendent Sprinklers are available in various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings have been investigated for installation in corrosive environments and are listed/approved as indicated in the approval charts. NOTE: When installed in some corrosive environments, the Polyester finish may change color. This natural discoloration over time is not in itself an indi- cation of corrosion and should not be treated as such. All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. LISTINGS AND APPROVALS c®us cULus Listed: Category VNlV FM Approved: Classes 2013 and 2015 NYC Approved: MEA 89-92-E, Volume 37 LPCB Approved: Ref. No. 096e106 (E CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPR-S0021 tW MED Certified: Standard EN 12259-1, EC-certificate 0832-MED-1003 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1991. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar). Factory tested pneumatically to 100 psi (6.89 bar) Thread size: 1" NPT or 25 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) for all listed and approved lengths. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Covered by the following U.S. Patents: 8,636,075 cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). -Metric K-factor measurement shown is when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Form No. F_071591 18.06.21 Rev 18.1 Replaces Form No. F_071591 Rev 16.1 (updated MED approval; revised terminology) Page 2 of 7 STANDARD RESPONSE l:II[.iu,yy DRY PENDENT STANDARD JII(IFs1G ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Pip Cap: Brass UNS-C31400 or UNS-C31600 Pip Cap Adapter: Brass UNS-C36000 Seat (for Sprinklers VK151, VK155, and VK159 only): Copper UNS-C21000 Orifice: Copper UNS-C22000 or UNS-C11000 (Copper UNS-C21000 for Sprinklers VK151, VK155, and VK159) Gasket (for Sprinklers VK151, VK155, and VK159 only): Buna-N Tube: ERW Hydraulic Steel Tube Barrel End and Threads (for Sprinklers VK150, VK154, and VK158): QM Brass Support (Internal): Stainless Steel UNS-530400 Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 ENT Coated Adjustable and Recessed Escutcheons: Stainless Steel UNS-530400 Ordering Information: (Also refer to the current Viking price list.) Order Standard Response Dry Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish, the appropriate suffix for the temperature rating, and then the suffix for the length ("A" dimension) to sprinkler base part number. Order in a specific length noted as the "A" dimension (see Figures 3 through 5). The "A" dimension is the distance from the face of the fitting (tee) to the desired finished surface of the ceiling. These sprinklers are listed and approved in lengths from 1-1/2" to 45-1/2" (38.1 to 1,156 mm) for the adjustable standard style, 3" to 47" (76.2 to 1,194 mm) for the plain barrel style, and 3-1/4" to 47-1/2" (82.5 to 1,207 mm) for the adjustable recessed style. Lengths exceeding the standard lengths are available, with no approvals, on a "made-to-order" basis: Recessed Dry Pendent up to 65-1/2" (1,664 mm). Adjustable Standard Dry Pendent up to 63-1/2" (1,613 mm). Plain Barrel Dry Pendent up to 65" (1,651 mm). Contact the manufacturer for more information. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, and ENT = JN Temperature Suffix ("F/"C): 155°/68" = B, 175"/79" = D, 200"/93" = E, 286°/141" = G For example, sprinkler VK154 with 1" NPT Threads, a Chrome finish and a 155 °F/68 "C temperature rating, and "A" length of 10" = Part No. 07740UFB10. Available Finishes And Temperature Ratings: Refer to Table 1. Wrench Accessories: (Also refer to the Viking website.) Flut Protective Sprinkler Wrenches: Sprinkler Standard Wrench: Part No. 07297W/B (available since 1991) Shield Wrench for recessed sprinklers: Part No. 07565W/Bt (available since 1991) tA /2" ratchet is required (not available from Viking). Sprinkler Guard: Chrome, with no listings or approvals, for installation on dry pendent sprinklers manufactured after May 1994 only (Part No. 08954). Replacement Escutcheons: Adjustable Standard Dry Escutcheon: Base Part No. 07741 Recessed Dry Escutcheon Cup: Base Part No. 05459A Go7'Q INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION Figure 1: Standard Sprinkler Wrench 07297W/B During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the internal parts to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. Form No. F_071591 18.06.21 Rev 18.1 Page 3 of 7 NIKING4 STANDARD IIIL RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. AVAILABILITY The Viking Standard Response Dry Pendent Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal - Maximum Ambient - Classification , Temperature Rating' Ceiling Temperature2 Bulb Color Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 F (65 C) Yellow Intermediate 200 °F (93 C) 150 F (65 C) Green High 286 OF (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, and ENT Corrosion-Resistant Coating3'4: White Polyester and ENT in all temperature ratings Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. ' The corrosion-resistant Polyester and ENT coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Note: These coatings are NOT cor- rosion proof. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environ- ment. Polyester and ENT coatings are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. When installed in some corrosive environments, the Polyester finish may change color. This natural discoloration over time is not in itself an indication of corrosion and should not be treated as such. All sprinklers Installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. _ .j. Wrench 07565W/Bww must be used for Installing recessed dry sprinklers Step 2 Carefully press Step 1 Carefully - ww 1/2 ratchet .—J the wrench upward and slide the wrench Is required (not turn slightly to ensure sideways around the available from Viking). L...... engagement with the the sprinkler deflector sprinkler wrench ff1ots. Figure 2: Wrench 07565W/B for Adjustable Recessed Dry Pendent Sprinklers Form No. F_071591 18.06.21 Rev 18.1 Page 4 of 7 sj II(IFs16i STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Approval Chart I (UL) T-Watm KEY Standard Response Standard Orifice Dry Pendent Sprinklers ;<, FIflish AIX 4- Esu**, (W cIe)l Maximum 175 PSI (12 bar) WWP Sprinkler Thread Size Nominal Order Length Listings and Approvals4 Base SIN Style K-Factor2 Increment (Refer also to Design Criteriabelow.) Part No.' NPT BSP U.S. metric3 Inches mm cULus' NYC8 LPCB ( 07740U VK154 Adjustable Standard - 5.6 - 1/2" 12.7 Al, A6 Al - - - - 07854U 25 mm - __ 80.6 __ 1/2" 12.7 Al, A6 - - - - 09341 VK155 - 25 mm - 80.6 1/2" 12.7 - - - A2 A2 A2 06530U VK158 Adjustable Recessed 1" - 5.6 - 1/4" 6.35 B3, B7 B3 - - - - 07853U - 25 mm - 80.6 1/4" 6.35 B3, B7 - - - - - 20239U - 5.6 - 1/4" 1 6.35 - - C9 - - - 20374U - 25 mm - 80.6 1/4" 6.35 - - C9 - - - 09342 VK159 25 mm - 80.6 1/4" 6.35 - - - B3 B3 B3 07852U VK150 1 _ Plain Barrel 1" - 5.6 - 1/2" 12.7 A4, AB A5 - - - - 07855U - 25 mm - 80.6 1/2" 12.7 A4. A8 - - - - - 09343 VK151 25 mm - 80.6 1/2" 12.7 - - - A5 AS A5 Approved Finishes and "A" Dimensions - Chrome or White Polyester' sprinkler with a Chrome or White Polyester Sleeve and Approved Temperature Ratings Escutcheon with 'A" dimensions 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) "A" 2 - Chrome with dimensions 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) A - 155 'F (68 'C), 175 'F (79°C), 200 'F (93 'C), 3-Chrome or White Polyester' with "A" dimensions 3-1/4' to 47-1/2" (82.5 to 1,207 mm) and 286 'F (141 'C) 4 - Chrome, White Polyester', or Brass with 'A" dimensions 3" to 47" (76.2 to 1,194 mm) 'A" 5-Chrome or Brass with dimensions 3" to 47" (76.2 mm to 1,194 mm) B - 155 'F (68 'C), 175°F (79°C), and 200°F (93 'C) 6- ENT' sprinkler with an ENT' Sleeve and Escutcheon with 'A" dimensions 1-1/2" to 45-1/2" C - 155 'F(68 'C) (38.1 mm to 1,156 mm) 7 - ENT' with "A" dimensions 3-1/4" to 47-1/2" (82.5 to 1,207 mm) ENT' with "A" dimensions 3" to 47"(76.2 to 1,194 mm) Chrome with "A" dimensions 3-1/4" to 47-1/2" (82.5 to 1,207 mm) Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ("A" Dimensions indicated above). Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 'Listed by Underwriter's Laboratories for use in the U.S. and Canada. 'Apted for use. City of New York Department of Buildings, MEA 89-92-E, Vol. 37. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPR-50021. 'MED Certified, Standard EN 12259-1, EC-certificate 0832-MED-1003. 'cULus Listed as corrosion resistant. DESIGN CRITERIA - UL (Also refer to Approval Chart I above.) NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-BI tees. When selecting other CPVC fittings, contact Viking Technical Services. cULus Listing Requirements: Standard Dry Pendent Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray pendent sprinklers. Designed for use in Light, Ordinary, and Extra Hazard occupancies. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Locate no less than 4" (102 mm) from walls. Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured per- pendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F071591 18.06.21 Rev 18.1 7 2-7/16' T61.9 - mm) - Minimum ceiling opening Minimum diameter,- 1-3/4' (44.5 mm). Maximum ceiling hole d1nmp1pr, 2-1/4' (7 mm. Finished - Ceiling 1-1/21- (38.1 mm) diameter - 13/16' (20.6 mm) Sleeve finish matches escutcheon (77.8 mm) Page 5 of 7 STANDARD RESPONSE '1 I FJ F'1G i:iI[.q..u'yf,v DRY PENDENT STANDARD ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page. For 'A' Dimension, 1. Determine the distance from the face of the tee to the finished ceiling. 2. Round to the nearest 1/2' (12.7 mm) between 1-1/2' and 45-1/2' (38.1 rim and 1,156 mm). NOTE' The deflector will be located approximately 3-7/16' (87.3 rim) below the ceiling. with 1' (25.4 mm) upward and 1' (25.4 mm) downward adjustment Deflector' at minimum distance below ceiling. Deflector at maximum distance below ceiling. NOTE' To locate the deflector at the minimum distance below the ceiling, with no upward adjustment available, order the dry pendent sprinkler 1' (25,4 mm) shorter than the A dimension. NOTE' To locate the deflector at the maximum distance below the ceiling, with no downward adjustment available, order the dry pendent sprinkler 1' (25.4 mm) longer than the A dimension. Figure 3: Adjustable Standard Dry Pendent Sprinkler For 'A' Dimension Determine the distance from the face of the A tee to finished ceiling. Round to the nearest Minimum ceiling 1/4 (6.35 mm) between opening size 2-1/8' (54 3-1/4' (82.5 mm) and diameter. " 47-1/2' (1,219 mm). Maximum ceiling NOTE' The sprinkler will be opening size: I-"-------1 recessed approximately 2-1/2' (63.5 mm) I I 5/16' (7.9 mm) above the diameter. I finished ceiling with 5/8' Adjustment , (15.8 mm) vertical adjust- 5/16'ment ...... . ...... available. ----- Minimum:_ - 'Finished ceiling 1' (25.4 nr,)] Maximum: 3-1/16' 1-5/8' (42.1 mm) - (77.9 mm) Figure 4: Adjustable Recessed Dry Pendent Sprinkler Form No. F_071591 18.06.21 Rev 18.1 A Outside For 'A' Dimension: diameter: 1-5/16' " - 1. Determine distance (33.4 mm) from face of the (same as 1' tee to the base (25 mm) of the sprinkler. Schedule 2. Round up to next 40 pipe). higher 1/2' (12.7 mm) increment between 3' (76.2 mm) and 47' (1,194 mm). 'TY mm) Figure 5: Plain Barrel Dry Pendent Sprinkler Page 6 of 7 N41KJNG* - STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Approval Chart 2 (FM) Standard Response Standard Orifice Dry Pendent SprInklers ESCAdw Maximum 175 PSI (l2bar) WWP Sprinkler Thread Size Nominal K-Factor2 Order Length Increment FM Approvals4 Base Part No.' SIN Se (Refer also to Design Criteria below.) NPT BSP U.S. metric3 Inches mm 07740U VK154 Adjustable Standard 1° - 5.6 - 1/2" 12.7 Al 07854U - 25 mm - 80.6 1/2" 12.7 Al 06530U Adjustable Recessed 1" - 5.6 - 114" 6.35 B2 07853U - 25 mm - 80.6 1/4" 6.35 B2 07852U VK150 Plain Barrel 1° - 5.6 - 1/2" 12.7 A3 07855U - 25 mm - 80.6 1/2" 12.7 A3 Approved Temperature Ratings Approved Finishes and "A" Dimensions A- 155°F (68 °C) 175°F (79°C) 200°F (93 "C) and 1 - Brass, Chrome, White Polyester, or ENT5 sprinkler with a Brass, Chrome, White Polyester, or , ' 286 °F '141 ENT5 Sleeve and Escutcheon with "A" dimensions 1-1/2" to 45-1/2" (38.1 to 1,156 mm) B - 155 F (68 C), 175 F (79 C), and 200 F (93 C) "A" 2 - Brass, Chrome, White Polyester, or ENT5 with dimensions 3-1/4" to 47-1/2" (82.5 to 1,207 mm) "A" 3- Brass, Chrome, White Polyester, or ENP with dimensions 3" to 47" (76.2 to 1,194 mm) Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ("A" Dimensions indicated above). Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any ad- ditional approvals. FM Approved as corrosion proofing for corrosive environments. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nlbco Model 5012-S-BI tees. When selecting other CPVC fittings, contact Viking Technical Services. FM Aeproval Requirements: Standard Dry Pendent Sprinklers in the Approval Chart above are FM Approved as standard response Non-storage standard spray sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including 2-0) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_071591 18.06.21 Rev 18.1 Ambient exposed Barrel Ambient Temperature Temperature aoy,4'clsoT/lotl6o'r,16T of Protected Areaw at th Exposed Minhuri Barrel Discharge End Lengthll Face of Tee of the Sprinkle to Top of Ceiling In. Ovi) T(.) 40'F (4'C) 0 0 30F (-1'0 0 : 20'F (-7'C) 14(100) C) (203) 1(254) - - 'C) 2(305) 3(76) - - 3'C) 4(356) 4(102) 1(25,4) 9C) 4(356) 6(152) 3(76) 4'C) MC-46*0 6(406) 9 (2014 (102) 40'C) 8(457) 8(203) ;F 565 6'C 0(508) 10(254 6(152) 51'C) 0(508) 10(254 6(152) (Exposed Barrel) Ceiling —J 1-1/2' (38,1 mm) diameter (Protected Area) Page 7 of 7 \1II(IF16® STANDARD RESPONSE i.l:ii[.qiu,7ayA DRY PENDENT STANDARD ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page. ,—Install 1 Inch NPT threaded end of dry pendent sprink-ler into the 1 Inch NPT outlet of a malleable iron tee fitting per ANSI B 16.3 (Class 150) or cast iron threaded tee fitting per ANSI 16.4 (Class 125) only. Minimum ceiling opening diameter' Minimum __j adjustment Qvali able, order the 1-3/4' (44.5 mm) dry pendent sprink- Maximum ceiling opening diameter' Deflector at ter 1' (25.4 mm) 2-1/4' (57 mm), minimum distance shorter nthan the Seal the clearance below ceiling 'A' dime sion. space around the sprinkler to avoid Leak- Note age of air into the [i To locate the protected area and ______ ______ dflector at the e 13/16' consequent formation ________________ maximum distance J (20.6 mm) of condensate around below the ceiling, frame, which could J with no downward Inhibit operation or adjustment avail- ' cause premature opera- able, order the tion. Refer to Figure (112,7 mm) dry pendent sprink- Sleeve 7 below, Maximum ter 1' (25,4 mm) I finish If humidity and temp- longer than the dimension, I A' matches erature differential ' causes condensation _1escutcheon on the exposed dry sprinkler, consider Deflector at wrapping the exposed maximum distance barrel with insulation, below ceiling foam insulating tape, or equivalent. Up to 2' (50.8 mm) adjustment available, Note' To locate the deflector at the minimum distance below the ceiling, with no upward *The protected area refers to the area below the ceiling. The ambient temperature Is the temperature at the discharge end of the sprinkler. For protected area temperatures that occur between the values listed, use the next cooler temperature. wwThe minimum required barrel length is not the same as the 'A dimension. Refer to Figures 3-5 for the 'A' dimension. NOTE' Exposed minimum barrel lengths are inclusive up to 30 mph wind velocities. Figure 6: Dry Pendent Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry Pendent Sprinkler Is shown) Seal or equivalent method) Seat Clearance Insulated Opening Ceiling Dry (,I I -I-I, ry Sprinkler er ea on e Dry Sprinkler Seal Within the Ceiling Exterior of the Ceiling Figure 7: Dry Sprinkler Seal (Adjustable Standard Dry Pendent Sprinkler is Shown) Form No. F_071591 18.06.21 Rev 18.1 Replaces Form No. F_071591 Rev 16.1 (updated MED approval; revised terminology) Page 1 of 6 MICROFAST® QUICK .1I FJ W*j PENDENT RINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small ther- mosensitive glass bulb spray sprinkler available with various finishes and tempera- ture ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Charts. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 (LPCB) LPCB Approved: Certificate 096e106 .- .- (( CE Certified: Standard EN 12259-1, certificate of constancy of performance 0832-CPR-50021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) .cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135°F (57 °C) =A, 155°F (68 °C) = B, 175°F (79 °C) = D, 200 °F (93 °C) = E, 286°F (141 °C) = G Form No. F_033314 18.06.21 Rev 18.1 Replaces Form No. F_033314 Rev 17.1 (Updated MED approval; added LPCB certificate number) Page 2 of 6 MICROFAST® QUICK w4j ::RESPONSE RINKLER VK302 (K5.6) PENDENT The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com For example, sprinkler VK302 with a Brass finish and a 155 OF (68 C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A Y2 ratchet is required (not available from Viking). Allows use from the floor by attaching a length of V diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast5 Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler Clip rench Flat tive Sprinkler Cap 10896 iFAMM"Mm Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_033314 18.06.21 Rev 18.1 [1 Sprinkler wrench 13655W1B* for recessed pendent sprinklers A1/2" ratchet is required (not available from Viking) [1 Page 3 of 6 N411awbo MICROFAST® QUICK I.l:II[siU,1ifa :RESPONSE PENDENT RINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER•TEMPERATURE U1RATINGS FINISHES Ordinary 135 °F (57 °C) 100 °F (38 °C) I Orange Ordinary 155°F(68°C) 100F(38°C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 C) Green High 286 °F (141 °C) 225 ¶ (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, and Black Polyester. ENT in all temperature ratings except 135 ¶ (57 °C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_033314 18.06.21 Rev 18.1 Page 4 of 6 'sJ IIING®MICROFASTO QUICK l.4:II[.qiu,nfA RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945-9501 Technical Services: 877.384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) Temper The Viking Microfaste Quick Response Pendent Sprinkler VK302 A& ci Maximum ITS PSI (12 Bar) WWP Base Sprinkler Thread Size Nominal Overall Listings and Approvals' Part SIN K-Factor Length (Refer also to Design Criteria.) Number' Style metric2 Inchesl mm cULus' VdS LPCB (E 12979 VK302 Pendent 1/2 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X Al A1Z, B1Y D1Z, C1Y D1W - 19780 VK302 Pendent 1/2" - - 5.6- 80.6 - 2.1/4 58 - - - - - D3 21354 VK302 Pendent - 15mm . 80.6 2-1/4 58 - - - - - D3 - W7I1 Zlii 06662B VK302 Pendent 1/2" 15 mm 1 5.6 80.6 11 2.1/4 58 A1Z, B1Y, D2, C2X I - - - - - 18021 VK302 Pendent 1/2 115 mm 1 5.6 1 80.6 1 2-1/4 58 AiX, B1Y I Al JA1X,B1YJD1X,C1YJ D1W I - Approved Temperature Ratings Approved Finishes Approved Escutcheons A - 135 °F (57 °C), 155 °F (68 °C), 175 °F 1 - Brass, Chrome, White w - Recessed with the Model F-i Adjustable Escutcheon only (79 °C), 200 "F (93 "C), 286 °F (141 'C) Polyester68, Black Potyes- X - Standard surface-mounted escutcheon or the B -135°F (57 'C), 155°F (68 'C), 175°F ter" Viking Micromatice Model E-1 Recessed Escutcheon (79 'C), and 200 'F (93 'C) 2- ENT5 Y - Standard surface-mounted escutcheon or the C. 155 'F (68 'C), 175 'F (79 'C), and 3-Chrome Viking Microfast5 Model F-i Adjustable Escutcheon, or recessed with the Viking Micro- 200 'F (93 'C) matic' Model E-1, E-2, or E-3 Recessed Escutcheon D - 155 'F (68 'C), 175 'F (79 'C), 200 'F Z - Standard surface-mounted escutcheon or the (93 'C), 286 'F (141 'C) Viking Microfasf5 Model F-i Adjustable Escutcheon Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of constancy of performance 0832-CPR-S0021. 8 MED Certified, Standard EN 12259-1, EC-0832-MED-1003. DESIGN CRITERIA- UL (Also refer to Approval Chart I above.) cULus Listing Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F033314 18.06.21 Rev 18.1 Page 5 of 6 -a-- MICROFAST® QUICK iJ I IJ I1G i : SPRINKLER VK302 (K5.6) RESPONSE PENDENT The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) F The Viking Microfast Quick Response.. 1 FU3fl Pendent Sprinkler VK302 AiX.- Esdecn WapØcabe) Maximum 175 PSI (i2Bar) Base Part SIN Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals3 NPT BSP U.S. metr1c2 Inches mm Number' Style (Refer also to Design Criteria.) 12979 VK302 Pendent 1/2' 1 m 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 (.1IL. 1:I1'l Limited (Contact Local Viking Office) 066628 VK302 Pendent 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent I..JL.. 15 mm 5.6 80.6 2-1/4 1 58 1 A1Z, B1Y Approved Escutcheons Approved Temperature Ratings x - Standard surface-mounted escutcheon or the A- 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F Viking Micromatic5 Model E-1 Recessed (93 °C), 286 °F (141 °C) Approved Finishes Escutcheon B -135°F (57 °C), 155 °F (68 °C), 175°F (79 °C), and 1-Brass, Chrome, White Polyester", Y - Standard surface-mounted escutcheon or the 200 °F (93 °C) and Black Polyester' Viking Microfast5 Model F-i Adjustable Escutcheon, C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 2 - ENT5 or recessed with the Viking Micromatic Model E-1 °F (141 °C) or E-2 Recessed Escutcheon D - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C) Z - Standard surface-mounted escutcheon or the Viking Microfast5 Model F-i Adjustable Escutcheon Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion proofing for corrosive environments. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Anaroval Requirements: The Viking Microfaste Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 18.06.21 Rev 18.1 Page 6 of 6 MICROFASP QUICK sJ I IJ Ij1G RESPONSE PENDENT - SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 1/2" 2-5/16" (59 mm) minimum (15 mm) ___________ 2-1/2" (64 mm) maximum NPT ________________ (54 ----I mm) 2-1/4 I1 1-3/4" 2" L • 1 1(38 mm) (57 mm) L I I I J (45 mm) (51 mm) , $ Mm. L J Installed with a standard Installed with a Microfast Note: At maximum, adapter 1/8" surface-mounted Model F-I Adjustable Is exposed 112" (13 mm) escutcheon Escutcheon from face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon it - (54 mm) C. IlL - 1-3/4" - (45 mm) Max. Ceiling Opening Size: 2-5/16" (59 mm) minimum It 2-1/2" (64 mm) maximum -•t. .-, :. 54 mm) --- 1-1/8" I (29 mm) 2" Mm. (51 mm) Max. 1-1/8" (29 mm) Mm. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-I and E-2 Recessed Escutcheons Form No. F_033314 18.06.21 Rev 18.1 Replaces Form No. F_033314 Rev 17.1 (Updated MED approval; added LPCB certificate number)