2659 GATEWAY RD; 107; FPC2018-0084; Permit
PERMIT REPORT (City of Carlsbad Print Date: 10/18/2021 Job Address: 2659 GATEWAY RD, # 107, CARLSBAD, CA 92009-1761 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2131912500 Track #: Valuation: $43,858.93 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: MENCHIES -SPRINKLER TI (14 HEADS) Permit No: FPC2020-0084 Status: Closed - Finaled Applied: 05/11/2020 Issued: 05/26/2020 Finaled Close Out: 08/14/2020 Inspector: Final Inspection: Applicant: FPContractor: CJ SUPPRESSION INC Cl SUPPRESSION INC ROBIN MOYER 205 LEWIS CT 205 LEWIS CT CORONA, CA 92882-1812 CORONA, CA 92882-1812 (951) 735-5560 (951) 735-5560 FEE AMOUNT FIRE NFPA 13 or 13R System 7- 100 heads --- $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Worldwide S tqCA7(i, Contacts www.tyco-fire.com Dry-type Sprinklers - - - and Horizontal Sidewall [-factor, Standard Response, Standard Coverage Series DS-1 - 56 Pendent. Uriht S S General Description TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response (5 mm bulb), Standard Coverage Dry-type Sprinklers are dec- orative glass bulb automatic sprinklers typically used where: pendent sprinklers are required on dry pipe systems that are exposed to freezing temperatures (for exam- ple, sprinkler drops from unheated portions of buildings) sprinklers and/or a portion of the connecting piping may be exposed to freezing temperatures (for exam- ple, sprinkler drops from wet systems into freezers, sprinkler sprigs from wet systems into unheated attics, or horizontal piping extensions through a wall to protect unheated areas of a building such as loading docks, over- hangs, and building exteriors) sprinklers are used on systems that are seasonably drained to avoid freezing (for example, vacation resort areas) IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 NOTICE Series DS-1 Dry-type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Series DS-1 Dry-type Sprinklers must only be installed in fittings that meet the requirements of the Design Crite- ria section. Sprinkler Identification Numbers (SINs) TY3255 - Pendent TY3155 - Upright TY3355 - Horizontal Sidewall Technical Data Approvals UL and C-UL Listed FM Approved VdS Approved 1Y3255 w/Standard Escutcheon only NYC Approved under MEA 352-01-E LPCB Approved Reference No. 094a/11 CE Certified Certificate of Conformity No. 0832- CPD-2015 (See Tables A and B for details.) Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connections 1 in. NPT ISO 7-A 1 MARCH 2019 Discharge Coefficient K=5.6 gpm/p5i½ (80,6 1pm/bar½) Temperature Ratings See Tables A and B. Finishes Sprinkler: See Table D. Escutcheon: See Table D. Physical Characteristics Inlet .............................Copper Plug.............................Copper Yoke.......................Stainless Steel Casing.............Galvanized Carbon Steel Insert.............................Bronze Bulb Seat...................Stainless Steel Bulb (5 mm dia.) .....................Glass Compression Screw .................Bronze Deflector ..........................Bronze Frame ............................Bronze Guide Tube .................Stainless Steel Water Tube .................Stainless Steel Spring .....................Stainless Steel Sealing Assembly. . Beryllium Nickel w/TEFLON Escutcheon. . . . Carbon Steel or Stainless Steel TFP500 TFP500 Page 2 of 10 SPRINKLER TYPE ESCUTCHEON TYPE TEMPERATURE RATING BULB COLOR CODE SPRINKLER FINISH NATURAL BRASS CHROME PLATED POLYESTER* PENDENT (TY3255) STANDARD 135°F (57°C) Orange 1,2, 3, 4, 5, 6 1,2, 4, 5, 6 155°F(68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 1,2, 3, 6 1, 2, 6 RECESSED 135°F (57°C) Orange 1,2,3,5 1,2,5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 1,2 360°F (182°C) Mauve N/A DEEP 135°F (57°C) Orange 1,2,3,4,5 1,2,4, 5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve WITHOUT 135°F (57°C) Orange 155-F (68-C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 1, 2, 3 1,2 UPRIGHT (TY3155) WITHOUT 135°F (57°C) Orange 1, 2, 3, 4, 5 1, 2, 4, 5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 360-F (182-C) Mauve 1,2,3 1,2 Notes: Listed by Underwriters Laboratories, Inc. (UL), maximum order length of 48 in. Listed by Underwriters Laboratories for use in Canada (C-UL), maximum order length of 48 in. Approved by FM Global (FM Approvals), maximum order length of 48 in. Loss Prevention Certification Board (LPCB) and CE conformity apply to these temperature ratings only Approved by the City of New York under MEA 352-01-E Approved by VdS Frame and deflector only N/A - Not Applicable TABLE A SERIES DS-1 PENDENT & UPRIGHT DRY-TYPE SPRINKLERS, 5.6K, STANDARD RESPONSE LABORATORY LISTINGS AND APPROVALS S 0 S TFP500 Page 3 of 10 SPRINKLER FINISH SPRINKLER ESCUTCHEON TEMPERATURE BULB NATURAL BRASS CHROME PLATED POLYESTER*** TYPE TYPE RATING COLOR CODE 135°F (57°C) Orange 155°F (68°C) Red 175-F (79°C) Yellow STANDARD 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 135°F (57°C) Orange 155°F (68°C) Red HSW* (TY3355) DEEP 175°F (79°C) Yellow 1**, 2°°, 3°°°, 4, 5 1°', 2", 4, 5 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow WITHOUT 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 1°°, 2°', 5 1",2" Notes: Listed by Underwriters Laboratories, Inc. (UL), maximum order length of 46 in. Listed by Underwriters Laboratories for use in Canada (C-UL), maximum order length of 46 in. Approved by FM Global (FM Approvals), maximum order length of 48 in. Loss Prevention Certification Board (LPCB) and CE conformity apply to these temperature ratings only Approved by the City of New York under MEA 352-01-E Horizontal sidewall with top of deflector-to-ceiling distance of 4 to 12 in. (100 to 300 mm) Light and ordinary hazard occupancies only Light hazard occupancies only Frame and deflector Only TABLE SERIES DS-1 HORIZONTAL SIDEWALL (HSW) DRY-TYPE SPRINKLER, 5.6K, STANDARD RESPONSE LABORATORY LISTINGS AND APPROVALS t S PLUG WITH INLET SEALING . = ASSEMBLY - YOKE SPRING INLET BAND WATER II II TUBE CASING GUIDE — INSERT TUBE BULB FRAME SEAT 5 m BULB VENT HOLE COMPRESSION DEFLECTOR SCREW FIGURE 1 SERIES DS-1 DRY-TYPE SPRINKLER, 5.6K, STANDARD RESPONSE ASSEMBLY - WRENCH RECESS WRENCH t FLAT PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 7 WRENCH TFP500 Page 4 of 10 S SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING I LJ ORDER LENGTHS: I 2-3/4 to 48" 1-3/4 DIA. (69,9 to 1219,2 mm) (44,5 mm) IN 1/4 (6,4 mm) INCREMENTS FACE OF CEILING F- _tc 2-3/16" ± 1/8° 3" DIA. (55,6 :t 3,2 mm) (76,2 mm) FIGURE 3 PENDENT (TY3255) WITH STANDARD ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 3-3/4" to 48' (95,3 to 1219,2 mm) IN 1/4" (6,4 mm) 2-1/4" DIA. INCREMENTS (57,2 mm) FACE OF CEILING 13/8 17l'8 DIA (34,9 ± 3,2 mm) (73,0 mm) FIGURE 4 PENDENT (TY3255) WITH STANDARD RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING f LJ ORDER LENGTHS: ni 1/2' (12,7 to IN 1/4" INCRE 4-1/i (108,0: FIGURE 5 PENDENT (TY3255) WITH DEEP ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM 1-3/4(44,5mm) DEFLECTOR TO CEILING FIGURE 6 PENDENT (TY3255) WITHOUT ESCUTCHEON TOP OF DEFLECTOR ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 7 UPRIGHT (TY3155) WITHOUT ESCUTCHEON 0 ORDER LENGTHS: 2-3/4° to 48° (69,9 to 1219,2 mm) IN 1/4° (6,4 mm) INCREMENTS I 2-3/8 ± 1/8' 1 - - (60,3 ± 3,2 mm) F ACE OF FACE OF - SPRINKLER MOUNTING FITTING SURFACE 3" DIA. T (76,2 mm) SPRINKLER FITTING 1-3/~ (REFER TO DE CENTERLINE 5/16" CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 8 HORIZONTAL SIDEWALL (TY3355) WITH STANDARD ESCUTCHEON ORDER LENGTHS: 1/2" to 45-3/4' (12,7 to 1162,1 mm) IN 1/4" (6,4 mm) INCREMENTS 4-1/4..-+ 1/8" - ' 2-1/2" DIA. - - FACE O FACE OF F (108,0 ± 3,2 mm) (63,5 mm) I MOUNTING I SPRINKLER KA F- SURFACE FITTING S SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) 3-1/2 DIA. T (88,9 mm) CENTERLINE 5/16° OF WATERWAY (7,9 mm) FIGURE 9 HORIZONTAL SIDEWALL (TY3355) WITH DEEP ESCUTCHEON ORDER LENGTHS: I- 5-1/2" to 48" (139,7 to 1219,2 mm) IN 1/4' (6,4 mm) INCREMENTS FACE OF I- SPRINKLER FITTING MINIMUM 2-1/4" (57,2 mm) DEFLECTOR TO MOUNTING SURFACE S TFP500 Page 5 of 10 Operation When TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response, Standard Coverage Dry-type Sprinklers are in service, water is prevented from entering the assembly by the Plug with Sealing Assembly (see Figure 1) in the Inlet of the sprinkler. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, and the Bulb Seat is released. The compressed Spring is then able to expand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with Sealing Assembly from the Inlet, allow- ing the sprinkler to activate and flow water. Design Criteria TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response, Standard Coverage Dry-type Sprinklers are intended for use in fire sprinkler systems designed in accordance with the standard instal- lation rules recognized by the appli- cable listing or approval agency (for example, UL Listing is based on NFPA 13 requirements). For more information on LPCB Approval, contact Johnson Controls at the following office: Kopersteden 1 7547 TJ Enschede The Netherlands Tel: +31-(0)53-428-4444 Fax: +31-(0)53-428-3377 Sprinkler Fittings Install 1 in. NPT Series DS-1 Dry-type Sprinklers in the 1 in. NPT outlet or run of the following fittings: malleable or ductile iron threaded tee fittings that meet the dimen- sional requirements of ANSI B16.3 (Class 150) cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125) Do not install Series DS-1 Dry-type Sprinklers into elbow fittings. The Inlet of the sprinkler can contact the interior of the elbow. The unused outlet of the threaded tee is plugged as shown in Figure 12. 5/16" SPRINKLER FITTING (7,9 mm) (REFER TO DESIGN CENTERLINE CRITERIA SECTION) OF WATERWAY FIGURE 10 HORIZONTAL SIDEWALL (TY3355) WITHOUT ESCUTCHEON 0 TFP500 Page 6 of 10 Temperatures for Heated Area(1) Ambient Temperature 40°F 50°F 60°F Exposed to (4 C) (10-C) (16-C) Discharge End of Sprinkler Minimum Exposed Barrel Length(2), (mm) 40°F (4°C) 0 0 0 30°F (-1°C) 0 0 0 20°F 4 0 0 (-7°C) (100) 10°F 8 1 0 (-12°C) (200) (25) 0°F 12 3 0 (-18°C) (305) (75) -10°F 14 4 1 (-23°C) (355) (100) (25) -20°F 14 6 3 (-29°C) (355) (150) (75) -30°F 16 8 4 (-34°C) (405) (200) (100) -40°F 18 8 4 (-40°C) (455) (200) (100) -50°F 20 10 6 (-46°C) (510) (255) (150) -60°F 20 10 6 (-51°C) (510) (255) (150) Notes: For protected area temperatures that occur between values listed above, use the next cooler temperature. These lengths are inclusive of wind velocities up to 30 mph (18,6 kph). TABLE C EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS MINIMUM RECOMMENDED LENGTHS S You can also install Series DS-1 Dry- type Sprinklers in the 1 in. NPT outlet of a GRINNELL Figure 730 Mechanical Tee and GRINNELL G-FIRE Figure 522; however, the use of the Figure 730 Tee and Figure 522 for this arrangement is limited to wet pipe systems. The configuration shown in Figure 13 is only applicable for wet pipe systems where the sprinkler fitting and water- filled pipe above the sprinkler fitting are not subject to freezing and where the length of the dry-type sprinkler has the minimum exposure length depicted in Figure 11. See the Exposure Length section. For wet pipe system installations of 1 in. NPT Series DS-1 Dry-Type Sprin- klers connected to CPVC piping, use only the following TYCO CPVC fittings: 1 in. x 1 in. NPT Female Adapter (P/N 80145) 1 in. x 1 in. x 1 in. NPT Sprinkler Head Adapter Tee (P/N 80249) For dry pipe system installations, use only the side outlet of maximum 2-1/2 in. reducing tee when locat- ing Series DS-1 Dry-type Sprinklers directly below the branchline; other- wise, use the configuration shown in Figure 12 to assure complete water drainage from above Series DS-1 Dry-type Sprinklers and the branch- line. Failure to do so may result in pipe freezing and water damage. CEM Do not install Series DS-1 Dry-type Sprinklers into any other type fitting without first consulting the Johnson Controls Technical Services. Failure to use the appropriate fitting may result in one of the following: failure of the sprinkler to operate properly due to formation of ice over the Inlet Plug or binding of the Inlet Plug insufficient engagement of the Inlet pipe-threads with consequent leakage Drainage In accordance with the minimum requirements of the NATIONAL FIRE PROTECTION ASSOCIATION for dry pipe sprinkler systems, branch, cross, and feed-main piping connected to Dry Sprinklers and subject to freezing tem- peratures must be pitched for proper drainage. Exposure Length When using Dry Sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use Table C to determine a sprinkler's appropriate exposed barrel length to prevent water from freezing in the con- necting pipes due to conduction. The exposed barrel length measurement must be taken from the face of the sprinkler fitting to the surface of the structure or insulation that is exposed to the heated area. See Figure 11 for an example. For protected area temperatures between those given above, the minimum recommended length from the face of the fitting to the outside of the protected area may be determined by interpolating between the indicated values. Clearance Space In accordance with NFPA 13, when connecting an area subject to freez- ing and an area containing a wet pipe sprinkler system, the clearance space around the sprinkler barrel of dry-type sprinklers must be sealed. Due to tem- perature differences between two areas, the potential for the formation of condensation in the sprinkler and subsequent ice build-up is increased. If this condensation is not controlled, ice build-up can occur that might damage the dry-type sprinkler and/or prevent proper operation in a fire situation. Use of the Model DSB-2 Dry Sprinkler Boot, described in technical data sheet TFP591 and shown in Figures 14 and 15, can provide the recommended seal. S 0 TFP500 Page 7 of 10 S FACE OF SPRINKLER - - FITTING ' EXPOSURE Oman LENGTH (SEE DESIGN DSB-2 CRITERIA INTENDED SECTION) FOR FREEZER STRUCTURES FIGURE 11 EXPOSURE LENGTH RUN OUTLET PLUGGED SPRINKLER FITTING TO DRY (SEE DESIGN SYSTEM CRITERIA SECTION) I DSB-2 INTENDED FOR FREEZER STRUCTURES FIGURE 12 SPRINKLER FITTING UNHEATED AREA TO WET SIDE SYSTEM1 I OUTLET PLUGGED DSB-2 Lf\ SPRINKLER INTENDED I I FITTING FOR FREEZER I I (SEE DESIGN CRITERIA STRUCTURES SECTION) FIGURE 13 SPRINKLER FITTING HEATED AREA S STRAP TIES >1 ON OPPOSING SIDES OF BOOT) DSB-2 BOOT ADHESIVE 1-3/4 DIA. (44,5 mm) CLEARANCE HOLE INSULATED FREEZER STRUCTURE DS-1 SHOWN WITH STANDARD ESCUTCHEON FIGURE 14 MODEL DSB-2 DRY SPRINKLER BOOT WITH PENDENT SERIES DS-1 DRY-TYPE SPRINKLER 1-3/4' DIA. (44,5 mm) CLEARANCE INSULATED HOLE FREEZER ADHESIVE DSB-2" STRUCTURE BOOT \ STRAP TIES DS-1 (ENDS ON SHOWN WITH OPPOSING STANDARD SIDES OF ESCUTCHEON BOOT) FIGURE 15 MODEL DSB-2 DRY SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY-TYPE SPRINKLER 0 TFP500 Page 8 of 10 Installation TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response, Standard Coverage Dry-type Sprinklers must be installed in accordance with this section. General Instructions Series DS-1 Dry-type Sprinklers must only be installed in fittings that meet the requirements of the Design Cri- teria section. See the Design Criteria section for other important require- ments regarding piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) rating to 1/8 in. (3,2 mm) for the 360°F (182°C) rating. Obtain a leak-tight 1 in. NPT sprinkler joint by applying a minimum-to-maxi- mum torque of 20 to 30 lb-ft (26,8 to 40,2 N.m). Higher levels of torque may distort the sprinkler Inlet with conse- quent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under or over-tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Notes: Install pendent sprinklers only in the pendent position; install upright sprinklers only in the upright posi- tion. The deflector of a pendent or upright sprinkler is to be parallel to the ceiling. Install horizontal sidewall sprinklers in the horizontal position with their centerline of waterway perpendicu- lar to the back wall and parallel to the ceiling. Ensure the word "TOP" on the Deflector faces the ceiling. Step 1. With a non-hardening pipe- thread sealant such as TEFLON applied to the inlet threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Wrench-tighten the sprinkler using either: a pipe wrench on the Inlet Band or the Casing (see Figure 1) the W-Type 7 Sprinkler Wrench on the Wrench Flat (see Figure 2) Apply the wrench recess of the W-Type 7 Sprinkler Wrench to the wrench flat. Note: If sprinkler removal becomes necessary, remove the sprinkler using the same wrenching method noted above. Sprinkler removal is easier when a non-hardening sealant was used and torque guidelines were followed. After removal, inspect the sprinkler for damage. Step 3. After installing the ceiling or wall and applying a ceiling finish, slide on the outer piece of the escutch- eon until it comes in contact with the ceiling/wall. Do not lift the ceiling panel out of its normal position. When using the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling or wall). Then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Standard Response, Standard Cover- age Dry-type Sprinklers must be main- tained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. A Vent Hole is provided in the Bulb Seat (see Figure 1)to indicate if the Dry Sprinkler is remaining dry. Evidence of leakage from the Vent Hole indicates potential leakage past the Inlet seal and the need to remove the sprinkler to determine the cause of leakage; for example, an improper installation or an ice plug. Close the fire protec- tion system control valve and drain the system before removing the sprinkler. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. See the Installation section. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION, for example, NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 0 TFP500 Page 9 of 10 P/N* 60 - XXX I - X - I XXX SIN SPRINKLER ESCUTCHEON FINISH FINISH)1) Pendent with 96 TY3255 CHROME SIGNAL WHITE Standard Escutcheon (1 in. NPT) (Figure 3) 0 PLATED (RAL9003) - POLYESTER 93 Pendent with TY3255 Deep Escutcheon (1 in. NPT) (Figure 5) SIGNAL WHITE - NATURAL 1 (RAL9003) 97 Pendent with TY3255 BRASS POLYESTER Recessed Escutcheon (1 in. NPT) (Figure 4) Pendent without 92 TY3255 2 NATURAL BRASS Escutcheon (1 in. NPT) (Figure 6) BRASS PLATED 94 4 (RAL9003) (RAL9003) SIGNAL WHITE SIGNAL WHITE POLYESTER POLYESTER 53 CHROME STAINLESS PLATED STEEL CHROME CHROME - PLATED PLATED 98 Upright without I TY31597) __ Escutcheon (1 in. NPT) (Figure I TEMPERATURE I ORDER RATING(2) 1 LENGTH(3) Notes: Escutcheon Finish applies to sprinklers provided with escutcheons. 0 135°F (57°C) 360"F (182"C) temperature rating applies to non-recessed sprinkler assemblies. Dry-type Sprinklers are furnished based upon "Order Length" as mea- 1 155°F (68°C) sured per Figures 3 through 10, as applicable, and for each individual sprinkler where it is to be installed. After the measurement is taken, 2 175°F (79°C) round it to the nearest 1/4 in. increment. Use Prefix "I" for ISO 7-R I Connection (for example, -60-961-1-180). 3 200°F (93°C) 4 286-F (141-C) 5 360-F (182-C) TABLED SERIES DS-1 DRY-TYPE SPRINKLERS, 5.6K, STANDARD RESPONSE PART NUMBER SELECTION 4 Sidewall with Standard Escutcheon (1 in. NPT) (Figure 8) TY3355 Sidewall with TY3355 Deep Escutcheon (1 in. NPT) (Figure 9) Sidewall without TY3355 54 9 Escutcheon (1 in. NPT) (Figure 10) 055 5.50 in. 082 8.25 in. 180 18.00 in. 187 18.75 in. 372 37.25 in. 480 48.00 in. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indi- cate the full product name, including description and part number (P/N). Dry-type Sprinklers When ordering Series DS-1 5.6K Pendent, Upright, and Horizontal Side- wall, Standard Response, Standard Coverage Dry-type Sprinklers, specify the following information: SIN: TY3255 - Pendent TY3155 - Upright TY3355 - Horizontal Sidewall . Order Length: Dry-type Sprinklers are furnished based upon Order Length as mea- sured per Figures 3 through 10, as applicable. After the measurement is taken, round it to the nearest 1/4 in. increment. Inlet Connections: 1 in. NPT (Standard) ISO 7-R 1 (For information on ISO Inlet Thread Connections, contact your Johnson Controls Sales Representative.) Temperature Rating Sprinkler Finish Escutcheon Type and Finish, as applicable P/N from Table D Part numbers are for 1 in. NPT stan- dard order sprinklers. Orders for all other sprinkler assemblies must be accompanied by a complete description. Sprinkler Wrench Specify W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Sprinkler Boot Specify Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002 This part number includes one (1) Boot, two (2) Strap Ties, and 1/3 oz of Adhe- sive (a sufficient quantity for installing one boot). TFP500 Page 10 of 10 C C S 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 02019 Johnson Controls. All nights r000ecod. All specification, and otsor inforenetign shown were Eminent 0001 doner,rnnt revision data and oro subject to chengo withoot notice. Johnson AIV (' NATIONAL FIRE PROTECTION ASSOCIaTION mid NFPA cm registered tmdommtrs Cf Notonal RI. Prnranllnerdnsoclntloni TEFLON so regIstered trademark of DuPont Controls /8 x 16 ØH Places) CEILING PLATES AND FLANGES Fig. 610 (Formerly Afton Fig. 610) Ceiling Plate Size Range: /8 rod Material: Carbon Steel Finish: Electro-Galvanized per ASTM B633 Service: Ceiling plate mounts on the underside of wood and steel to support up to 4" NPS horizontal piping. Approvals: cULus Listed (UL 203) Installation: Mount on the underside of wood or steel using the fasteners listed in NFPA 13 and the mounting fastener table listed below. Fully thread the rod through the threaded mounting hole. Features: Fastener array optimizes the fastener size and placement for various structure types and pipe sizes. Ordering: Specify figure number, finish, and description. FIG. 610: WEIGHT (LBS) • DIMENSION (IN) Rod A B I C I 0 OH I Approx. Size Weight/100 2Ilh/4Hh/2H,4H/4 20 cULus LISTED MOUNTING FASTENERS POSITIONS QTY of 2 Fasteners OTY of 4 Fasteners 0 • . . OR • . I 0 cULus LISTED MOUNTING FASTENERS FOR STEEL PIPE Structure Fastener Options QTY Pipe Size Wood ¼'x1½" Lag Screw 2 #14x 1½" TEK Screw Wood 1/4' x 1½" Lag Screw 4 #14x1½"lEKScrew Steel 1%" x 1" TEK Screw 2 (14ga Mm) #14 x 1" TEK Screw Steel 1/4" x 1" TEK Screw 2 (16gaMin) #14x1" TEK Screw Steel ¼' x 1" TEK Screw 4 (16gaMin) #14x1" TEK Screw Steel (18ga Mm) #10 x 1"TEK Screw 4 :s 21/2" Steel (20ga Mm) #10 x " TEK Screw 4 :5 2½" Steel (22ga Mm) #10 x " TEK Screw 4 :5 2" Note: Sheet Metal Screws are acceptable alternatives for TEK Screws. If installing through gypsum board or sheetrock into wood, the fastener length must be increased. A minimum of 13/8" screw embedment in the wood is required. PROJECT INFORMATION APPROVAL1V1'I Project: Li Approved Address: Li Approved as noted Contractor: Li Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-1.1 8 SCHEDULE 10 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES In. mm in. mm in. mm Ibs./ft. kg/rn CRR* Lift 1¼ 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 1½ 1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 21/2 2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 4 4.500 114.3 4.260 108.2 .120 3.05 5.62 8.37 1.6 19 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 6 6.625 168.3 6.357 161.5 .134 3.40 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). SCHEDULE 40 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES In. mm in. mm in. mm Ibs./ft. kg/rn CRR Lift 1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 1% 1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 11/2 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 2 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR Is ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). C@ A~PPROVE>D FM Approved and Fully Listed Sprinkler Pipe Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, C-UL and FM Listed. Approvals and Specifications Both products meet or exceed the following standards: ASTM A135, Type E. Grade A (Schedule 10) ASTM A795, Type E, Grade A (Schedule 40) NFPA13 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe up to 6" receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black, or with hot-dip galvanizing, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is also UL Listed. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: 0 BLACK 0 HOT-DIP GALVANIZED , Wheatland Tube MC STEEL GROUP FireLock® Outlet-T STYLE 922 o The Style 922 Outlet-T provides a convenient method of incorporating ½, ~, and 1/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* It is supplied with a clear, rust inhibitive coating. Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E' Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para__________ Location Date Approved Date__________________________________ www.victaulic.com - taulic VIcTAuLIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. CD 2009 VITALIC COMPANY. ALL RIGHTS RESERVED. REV_F 10.52_1 Nominal Size Diameter . ji,.rl,.i,,o.pi,ri1IrnTncis Appr x. Weight Each 1¼ 32 ½ 15 PM 30.2 1.30 33.0 1.83 1.10 3.87 2.56 1.0 46.5 27.9 1 98.3 65.0 0.45 3/4 20 1 ,l6 30.2 1.28 32.5 1.83 1.10 3.87 2.56 1.1 46.5 27.9 98.3 65.0 0.50 1 25 1 3A6 30.2 1.52 38.6 2.18 1.10 3.87 2.56 1.2 55.4 27.9 98.3 65.0 0.54 1112 40 ½ 15 1,i6 30.2 1.42 1 36.1 1.95 1.22 1 4.08 56 1 1.2 1 49.5 31.0 103.6 65.0 0.54 3/4 20 1 146 30.2 1.40 35.6 1.95 1.22 4.08 2.56 1.2 49.5 31.0 103.6 65.0 0.54 1 25 1146 30.2 1.64 41.7 2.30 1.22 4.08 2.56 1.3 58.4 31.0 103.6 65.0 0.59 2 50 ½ > 15 1 ,16 30.2 1.66 42.2 2.19 1.46 4.60 2.56 55.6 37.1 116.8 65.0 1.3 0.59 3/4 20 1146 1.64 30.2 41.7 2.19 55.6 1.46 4.60 2.56 37.1 116.8 65.0 1.4 0.64 1.5 2½ 65 1 25 ½ x 15 1/o 30.2 PM 30.2 1.88 47.8 1.91 48.5 2.54 64.5 2.44 62.0 1.46 4.60 1 2.56 37.1 116.8 1 65.0 1.71 5.40 2.56 43.4 _j 5.0 0.68 1.6 0.73 Y4 20 PM 30.2 1.89 48.0 2.44 62.0 1.71 5.40 2.56 43.4 1 137.2 65.0 1.6 0.73 1 25 ½ 1 3A 30.2 1 3/6 2.13 54.1 1.91 2.79 70.9 2.44 1.71 5.40 2.56 43.4 137.2 65.0 1.71 5.50 2.56 1.6 0.73 1.6 61 7 . mm X 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 Y4 20 13A6 1.89 _9 48.962.0 2.44 1.71 43.4 5.50 2.56 139.7 65.0 1.6 0.73 1 25 1 3M 30.2 2.13 54.1 2.79 70.9 1.71 43.4 5.50 2.56 1.7 139.7 65.0 1 0.80 DIMENSIONS IP'WW L II. luI II i S IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 O t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victauIic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 1O.52_2 JtauIicr REV_F S FireLock® Outlet-I STYLE 922 o 0 IRS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 PERFORMANCE Run Size x Outlet Size Equivalent Length of 1 inch Schedule 40 Steel Pipe (per UL 213, Section 16) (C=120), FT Inches/mm Feet/meters 8.5 2.6 8.5 2.6 8.5 2.6 76.1 mm x 8.5 Hazen-Williams coefficient of friction is 120 S fl www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 29 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_F 4_t a _U, i C r 1O.52_3 STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV F UPDATED 2/2009 iCtUIiC vicrAuLic IS A REGISTERED TRADEMARK OF ICAULIC COMPANY. 0 29 vICTAuLIC COMPANY. ALL RIGHTS RESERVED 10.52 tqca® Worldwide Contacts I www.tyco-fire.com Series TYIFRB - 2.8.42.56. and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers described in herein are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers. They are designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls. The TY-FRB Recessed Pendent Sprin- kler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following Recessed Escutcheons: A two-piece Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) Recessed Escutcheon with 1/2 in. (12,7 mm) of recessed adjustment or up to 3/4 in. (19,1 mm) of total adjustment from the flush pendent position. A two-piece Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) Recessed Escutcheon with 1/4 in. (6,4 mm) of recessed adjustment or up to 1/2 in. (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided b the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond what would be obtained when exposed IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 to corrosive atmospheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the applicable approval agen- cies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corrosive environment. The effects of ambient temperature, con- centration of chemicals, and gas/ chemical velocity, should be consid- ered, as a minimum, along with the cor- rosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356. Sprinkler Guards are detailed in Technical Data Sheet TFP780. ESM The Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. NFPA 13 prohibits installation of 1/2 in. NPT sprinklers with K-factors greater than 5.6 in new construction. They are intended for retrofit in existing sprinkler systems only. JULY 2018 Sprinkler Identification Number (SIN) TY1131 . . . Upright 2.8K, 1/2 in. NPT TY1231.. Pendent 2.8K, 1/2 in. NPT TY2131 . . . Upright 4.2K, 1/2 in. NPT TY2231.. Pendent 4.2K, 1/2 in. NPT TY3131 . . . Upright 5.6K, 1/2 in. NPT TY3231.. Pendent 5.6K, 1/2 in. NPT TY4131 . . . Upright 8.0K, 3/4 in. NPT TY4231 .. Pendent 8.0K, 3/4 in. NPT TY4831 . . . Upright 8.0K, 1/2 in. NPT TY4931.. Pendent 8.0K, 1/2 in. NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion-resistant status. Maximum Working Pressure Refer to Table C TFPI7I 2-3/16' (55,6 mm) 1-1/2 (38,1 mm) STYLE 10 or 20 I- 2-7/8" (73,0 mm) DIA. —H RECESSED ESCUTCHEON RECESSED PENDENT CROSS SECTION TFPI7I Page 2 of 10 * Temperature rating ** Pipe thread connections per 1 - Frame is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Deflector. special request. PLATE SEATING SURFACE 7/16' (11,1 mm) / //4tI1 2-1/4 MAKE-IN NOMINAL (57,2 mm) 2-3/16 1-9/16 I (55,6 mm) 1/2 NPT** f WRENCH STYLE 10 or 20 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON 3 - Sealing 5 - Compression Assembly Screw 4 - Bulb 6 - Deflector* 7 - Bushing CROSS SECTION 2-7/8" (73,0 mm) DIA. —.-] RECESSED PENDENT FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 IN. NPT 3 - Sealing 5 - Compression Assembly Screw 4 - Bulb 6 - Deflector* * Temperature rating ** Pipe thread connections per 1 - Frame is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Deflector. special request. PLATE SEATING SURFACE I 7/16" (11,1 mm) NOMINAL I E-IN 2-3/16 MAIc (556 mm) 1/2' NPT** f WRENCH FLATS UPRIGHT PENDENT FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 IN. NPT Discharge Coefficient K=2.8 GPM/psi½ (40,3 LPM/bar½) K=4.2 GPM/psi½ (60,5 LPM/bar½) K=5.6 GPM/psi½ (80,6 LPM/bar½) K=8.0 GPM/psi4 (115,2 LPM/bar") Temperature Rating Refer to Table A and B Finishes Sprinkler: Refer to Table D Recessed Escutcheon: Signal or Pure White, Grey Aluminum, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly. . Beryllium Nickel w/TEFLON Bulb...............................Glass Compression Screw .................Bronze Deflector ...................Copper/Bronze Bushing (K=2.8) ....................Bronze Poly-Stainless Physical Characteristics Frame ............................Bronze Button ................L316 Stainless Steel' Bulb...............................Glass Compression Screw .....L316 Stainless Steel' Deflector ...................Copper/Bronze Sealing Assembly. Gold Plated Beryllium Nickel w/TEFLON 'Type L316 stainless steel IUNS 31603> per ASTM A479/479M or BS EN 1008 WN1.4404. Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers are intended for fire protection systems designed in accordance with the stan- dard installation rules recognized by the applicable Listing or Approval agency, such as UL Listing based on the requirements of NFPA 13 and FM Approval based on the requirements of the FM Global Loss Prevention Data Sheets. Use only the style 10, 20, 30, or 40 Recessed Escutcheon, as applica- ble, for recessed pendent installations. * Temperature rating is indicated on Deflector. ** Pipe thread connections per ISO 7-1 can be provided on special request. - 2-7/8' (73,0 mm) DIA. -] RECESSED PENDENT CROSS SECTION STYLE 10 RECESSED ESCUTCHEON 2-7/8" (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION 2-3/16" (55,6 mm) (38,1 mm) UPRIGHT PENDENT TFPI7I Page 3 of 10 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* ESCUTCHEON PLATE SEATING SURFACE 7/16 11,1mm) 2-3/16' MAKE-IN J[(NOMINAL /1' (55,6 mm) 1-1/2' I2-3/16" (38,1 mm) (55,6mm) 1/2" NPT** WRENCH STYLE 10or20 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 1/2" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated \I SURFACE 4 - Bulb 6 - Deflector* on Deflector. POLY-STAINLESS FINISH ONLY FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 IN. NPT Installation The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) and 3/32 in. (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N.m). A leak tight 3/4 in. NPT sprinkler joint should be obtained with a torque of 10 to 20 lb-ft (13,4 to 26,8 N.m). Higher levels of torque can distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to com- pensate for insufficient adjustment in the escutcheon plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series TY-FRB Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions: Step 1. Install pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1 to Figure 5, apply the W-Type 6 Sprinkler Wrench to the sprinkler wrench flats. Series TY-FRB Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1 t 4, apply the W-Type 7 Recessed Sprin- kler Wrench to the sprinkler wrench flats. Step 3. After the ceiling is installed or the finish coat is applied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Recessed Pendent Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. 2-7/8' (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION 2-7/8" (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION TFPI7I Page 4 of 10 * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector, special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1/2 _ _T H ' (12,7 mm) i' /16NOMINAL _____(58,7 mm MAKE-IN I 2-1/4 1-9/16 $ (57, (39,7 mm) I 2m/____ 3/4" NPT** I WRENCH STYLE 30 or 40 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 3/4" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated \ SURFACE 4 - Bulb 6 - Deflector* on Deflector. UPRIGHT 1/2 (12,7 mm) NOMINAL MAKE-IN 2-5/16' (58,7 mm) 16" (57,2 mm) STYLE 40 RECESSED PENDENT ESCUTCHEON POLY-STAINLESS FINISH ONLY FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 IN. NPT CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw - Sealing 6 - Deflector * / 7 3 Assembly 4 - Bulb / 2-1/4" (57,2 mm) * Temperature rating is 1-9/16" indicated on Deflector. (39,7 mm) I 5 ** Pipe thread connections I per ISO 7-1 can be 13 * 6 provided on special request. PENDENT CROSS SECTION 7/16" I (11,1 mm) I NOMINAL Ll ~ I MAKE-IN I 2-3/16" (55,6 mm) 1/2' NPT** I WRENCH FLATS UPRIGHT FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 112 IN. NPT TFPI7I Page 5 of 10 2-7/8" DIA. 5/8±1/4" (73,0 mm) I 3/4(19,1 mm) I (15,9±6,4 mm) / I 1/4" (6,4 mm) I FACE OF 2-1/4" DIA. (57,2 mm) MOUNTING SPRINKLER PLATE I FITTING I - (3,2 mm f MOUNTING 1-5/1' (33,3 mm) SURFACE 6 I CLOSURE SERIES TY-FRB 13/16" (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 IN. NPT 2-7/8' DIA. 5/8±1/4" (73,0 mm) I3/4' (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. I 1/4" (6,4 mm) I PLATE SPRINKLER FITTING 1/8" / FACE OF - (57,2 mm) MOUNTING (3,2 mm) \% MOUNTING I SURFACE SERIES 1-1/4(31,8 mm) 1 CLOSURE TV-FRB 3/4" (19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 IN. NPT 2-7/8" DIA. (73,0 mm) 1/2±1/8" 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA 1/4" (6,4 mm) FACE OF (57,2 mm) I MOUNTING SPRINKLER PLATE I FITTING 1/8" (3,2 mm) MOUNTING I r. J SURFACE 1-5/16" (33,3 mm) CLOSURE SERIES TY-FRB 1-1/16" (27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 IN. NPT 2-7/8" DIA. - 1/2:0/8" (73,0 mm) 1/2' (12,7 mm) (12,7+3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) I TT? - /FACE OF MOUNTING(57,2 mm) I SPRINKLER PLATE I I FITTING L7 (3,2 mm) I ________ __ $ MOUNTING $ SURFACE SERIES 1-1/4" (31,13 mm) CLOSURE TY-FRB 1" (25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 IN. NPT TFPI7I Page 6 of 10 2-7/8 DIA. 5/8±1/4' (73,0 mm) 3/40 (19,1 mm) (15,9±6,4 mm) 2-1/4' DIA. I 1/4" (6,4 mm) / FACE OF - (57,2 mm) MOUNTING SPRINKLER FITTING I 1/8" - (3,2 mm) PLATE ,"I'j MOUNTING SURFACE SERIES 1-1/4(31,8 mm) f CLOSURE TY-FRB 3/4' (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT 2-7/8' DIA. 5/8±1/4" (73,0 mm) 3/4(19,1 mm) (15,9±6,4 mm) - 2-1/4" DIA. 1/4' (6,4 mm) / FACE OF (57,2 mm) MOUNTING I SPRINKLER I PLATE FITTING 1/8 (3,2 mm) \% MOUNTING SURFACE - I . CLOSURE SERIES 1-5/16" (33,3 mm TYFRB 13/16" (20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 IN. NPT WRENCH RECESS (END "A" USED FOR 1/2' NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) I (12,7±3,2 mm) 2-1/4' DIA. 1/4" (6,4 mm) I I I /" FACE OF [572 mm1 MOUNTING SPRINKLER PLATE I FITTING L1(3,22 /8' /mm) 177-14 I £ It MOUNTING SURFACE SERIES 1-1/4" (31,8 mm) 1 CLOSURE TY-FRB 1" (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT 2-7/8' DIA. 1/2±1/8" (73,0 mm) 1/2' (12,7 mm) (12,7±3,2 mm) 2-1/4' DIA. 1/4" (6,4 mm) / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mi TYFRB 1-1/16" (27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 IN. NPT WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI7I Page 7 of 10 Sprinkler Finish5 K- Factor Type Temperature Bulb Liquid Color Natural Brass Chrome Plated Polyesterc 2.8 1/2 in. NPT Pendent (TY1231) and Upright (TY1131) 135°F (57°C) Orange 1, 2, 3, 4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Recessed Pendent (TY1231)a Figure 6 135°F (57°C) Orange 1,2,4 155°F (68°C) Red 175°F (79°C) Yellow 200°F(93°C) Green Recessed Pendent (TY1231)b Figure 7 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 4.2 1/2 in. NPT Pendent (TY2231) and Upright (TY2131) 135°F (57°C) Orange 1,2 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286-F (141-C) Blue Recessed Pendent (TY2231)a Figure 8 135°F (57°C) Orange 155°F (68°C) Red . 175°F (79°C) Yellow 200°F(93°C) Green Recessed Pendent (TY2231)b Figure 9 135°F(57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green NOTES Installed with Style 10(1/2 in. NPT) or Style 40(3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20(1/2 in. NPT) or Style 30 (3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed, the sprinklers are UL and C-UL Listed as corrosion- resistant sprinklers. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFPI7I Page 8 of 10 Sprinkler Finish8 K- Factor Type Temperature Bulb Liquid Color Natural Brass I Chrome Plated Polyesterc PolyStainlessC Lead Coated 135°F (57°C) Orange Pendent (TY3231) and 1, 2, 3, 4, 5, 6, 7 1,2 1,2, 3,5 155°F (68°C) Red 175°F (79°C) Yellow Upright (TY3131) Blue 200°F (93°C) Green 286°F (141°C) 135°F (57°C) Orange 155°F (68°C) Red 5.6 1/2 in. NPT Recessed Pendent (TY3231)a Figure 10 1, 2, 4, 5 1,2 N/Ad 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange 155°F (68°C) Red Recessed Pendent (TY3231)b Figure 11 1, 2, 3, 4, 5 N/A N/A 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Pendent (TY4231) and 135°F (57°C) Orange 1,2,3,4,5, 6, 7 1,2 1,2, 5 155°F (68°C) Red 175°F(79°C) Yellow Upright (TY4131) Blue 200°F (93°C) Green 286°F (141°C) 135°F (57°C) Orange 155°F (68°C) Red 8.0 3/4 in. NPT Recessed Pendent (TY4231)a Figure 12 1, 2, 5 1,2 N/A 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange 155°F (68°C) Red Recessed Pendent (TY4231)b Figure 13 1, 2, 3, 5 N/A N/A 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 8.0 1/2 in. Pendent (TY4931) and 135°F (57°C) Orange 1, 2, 4, 5, 6 N/A 1, 2, 5 155°F (68°C) Red 175°F (79°C) Yellow NPT Upright (TY4831) Blue 200°F (93°C) Green 286°F(141°C) NOTES Installed with Style 10(1/2 in. NPT) or Style 40(3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2 in. NPT) or Style 30(3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector Only. Not Available (N/A) Listed by Underwriters Laboratories, Inc., (UL( as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 9 of 10 Sprinkler Finish K- Factor Type Natural Brass I Chrome I Plated Polyester Lead Coated Pendent (TY1231) and 2.8 Upright (TY1131) 1/2 in. 175 psi (12,1 bar) N/A2 Recessed NPT Pendent (TY1231) Pendent (TY2231) and 4.2 Upright (TY2131) 1/2 in. 175 psi (12,1 bar) N/A Recessed NPT Pendent (TY2231) Pendent (TY3231) and 5.6 Upright (TY3131) 250 psi (17,2 bar) 1/2 in. or 175 psi (12,1 bar)' Recessed NPT Pendent (TY3231) Pendent (TY4231) 175 psi 8.0 and Upright (TY4131) (12,1 bar) 3/4 in. 175 psi (12,1 bar) NPT Recessed N/A Pendent(TY4231) 8.0 Pendent (TY4931) 175 psi 1/2 in. and 175 psi (12,1 bar) (12,1 bar) NPT Upright (TY4831) NOTES The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. )UL); the Listing by Under- writers Laboratories, Inc. for use in Canada )C-UL); and, the Approval by the City of New York. Not applicable (N/A). Care and Maintenance The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire pro- tection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to TABLE C MAXIMUM WORKING PRESSURE corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be taken to avoid damage to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or sprinkler manufac- turer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section). Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suff ice. Inspections of corrosion-resis- tant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprinkler condition and the long-term integrity of the corrosion-resistant material, which can be affected by the corrosive conditions present. I SPRINKLER FINISH 1 NATURAL BRASS - POLY-STAINLESS GREY 2 ALUMINUM (RAL9007)1 POLYESTER - PURE WHITE POLYESTER (RAL9010)2 - SIGNAL WHITE POLYESTER (RAL9003) - JET BLACK POLYESTER (RAL9005)3 7 LEAD COATED I TEMPERATURE RATINGS 135 135-F (57-C) 155 155°F(68°C) 175 175°F(79°C) 200 200°F (93°C) 286 286°F(141°C) 9 I CHROME PLATED TFPI7I Page 10 of 10 P/N 57— XXX- X- XXX SIN7~ 330 2.81K UPRIGHT (1/2 in. NPT) TY1131 331 2.8K PENDENT (1/2 in. NPT) TY1231 340 4.2K UPRIGHT (1/2 in. NPT) 1Y2131 341 4.2K PENDENT (1/2 in. NPT) 1Y2231 370 5.6K UPRIGHT (1/2 in. NPT) TY3131 371 5.6K PENDENT (1/2 in. NPT) TY3231 390 8.0K UPRIGHT (3/4 in. NPT) TY4131 391 8.0K PENDENT (3/4 in. NPT) TY4231 360 8.0K UPRIGHT (1/2 in. NPT) 1Y4831 361 8.0K PENDENT (1/2 in. NPT) TY4931 NOTES Available only on 1Y3131, TY3231, TY4131, and TY4231 Eastern Hemisphere sales only. Available in only 2.81<, 4.2K, and 8.0K, 155CF I68C} and 200'F (93°C): requires longer lead time to manufacture. TABLED SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright) Sprinkler (specify) temperature rating, (specify) finish or coating, PIN (specify from Table D) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 02010 Johnson Controls. All righlo rosornod. At specifications and other information shown wore Currant 000t document ronioion Auto and are subioct to oh—go without notice. NATIONAL FIRE PROTECTION ASSOCIATION and NFPA an, regislerod I,ndomnfl'. Of National Fire Prorentlnn Assonioliong TEFLON Iso reglalerod nodomorkol DuPont Johnson OV,Controls SAMMYS@ FOR WOOD No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. Watch a c,dvo dcmonsvalioa www.itwbuildex.comj i - #14 Black Nut Driver Part # 8113910 i . #14 SW Red Nut Driver Pert # 8114910 k.l'iIIL.1ItL.j.JIr 1/4" 8002957 .. GST 100 1/4x1 210 (7/16'OSB) — 25 125 r114.8003957 GST200 1/4x2" 1760 (Fir) 251252 114" 8004957 GST 300 1/4 x 3 2060 (Fir) 25 125 3/8" 8007957 GST 10 1/4x1" 210(7/16OSB) 300 - 25 125 L 670 314" Ply) 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 147525125 3/8 8068925 GST26-SS1/4 x2 1760 (Fir) 850 25 125 3/8" 8009925 GST 2S-3803/8x2-1/2" 2113 (Fir) 1500 25125 3/88010957 GST 3-0— 1/4x3 2060 (Fir) 1500 1475 25 125 3/8"8069925 GST 3O-SS1/4x3" 2060 (Fir) 25 125 3/8" 80925 GST40 114x4 2180 (Fir) 25 125 1/2" 8013925 GST2 1/4x2" 1760 (Fir)25125 1/2_8014925G9T25-3803/8x21/2_2113 (Fir)25125 1/2" 8015925 GST 3 1/403" 2275 (Fir) 25 125 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver conies into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Eliminates distortion of threaded rod. Accommodates up to 3 1V x 12 pitch roof. 'Allows 17' deflection from vertical. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. 1406 @ 45off vertical Dim. Lumber W@45* 25 125 903 Dim. Lumber 1406 @ 450ff vertical 25 125 Dim. Lumber '-'3AHff'Y9 Not less than 2' nominal width /; - ---.-.- (1-1/21 up to 3-1/2' pipe; not less than 3'(2-11T) nominal width 4'& 5 pipe - 4 Floor Joist Minimum 2-1/2' from bottom for __________ branch lines. Minimum 3' from trot- tom for mainlines. Exception: This requirement shallnot apply to 2' or thicker nailing strips resting on top of steel beams.00, 'No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. Ouuw,a vveodemonnauona\ wwwitwbulldex.comj I - 1/4' 8019957 SWG 200 i/4 -x--2'-1725 (Fir) 25 125 I ' 3/8 8020957 SWG10 1/4x1 622 (Fir) 300 25 125 - €1. 3/8' 8021957 SWG 20 114x2' 1725 (Fir) 1050 25 125 1 3/8' - 8073925 SWG2O-SS 1/4xT 1725 (Fir) 25 - 125 3/• 8022925 SWG 25-380 3/8s2-1/2' 2249 (Fir) 1500 25 125 #14 Sw Red !9P!. 1/4x2' 188 . Nut Driver Part #8114910 May require pre-driling; consult joist manufacturer iYY/tTk.ii ROD am NAZAEW Approvals Rod Part Model Size Number ri #14 Black : Nut Driver ..'&- 3/8' 8139957 SH-GST Part # 8113910 U' 3/8" 8269957 SH-GST/CST 20 5/1601-3/4' 1/2' 8303957 SH-GSTICST 2.0 5/160 1-3/4' I L May require pre-drilling; censuS joist manufacturer #14SH Orange Nut Driver Part # 8273910 F P P I Description Manufactured from .020" white coated aluminum. All sign types are screen printed with a fade resistant red ink. Each sign is shipped with a clear protective plastic coating which can be re- moved at time of installation. Each sign type meets or exceeds NFPA1 3 requirements. All signs (except 7" round) are drilled in four corners to allow for easy installation. All signs (except 7" round) may be installed with sign chain or with any fastener that is suitable for the material that the sign is being attached. The 7" round bell signs are center drilled to allow for installation directly to the bell gong assembly. Type "A" 9" x 7" Control valve signs are drilled with the same four hole pattern as Type "B" 6" x 2" signs to allow for attachment of Type "B" to Type "A". Installation Specifications Installation of aluminum signs is accomplished by several methods. The most common installation procedure is to use #16 Single Jack chain to hang the Material: .020" aluminum with sign on the area being identified. Since all of the above mentioned signs are removable plastic coating predrilled at all four corners, the last link of the chain can be opened and hooked through the top holes on the signs and hung on the appropriate valve or piping. The signs may also be fastened to a flat surface with fasteners appropriate to x 6" the base material. (The 9" x 7" Fire Alarm Bell sign must be drilled with a /8" hole x 7" if it is to be attached directly to the bell gong.) 210" 8.5" xli" 7" Round See current catalog for a full listing of all available signs. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 + 1 800 344-1822 FAX + 1800 344-3775 0 2012 Fire Protection Products, Inc. Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) ®Tc0 B32051 - Threaded Rod (right & left hand threads) Size Range: 3/8-16 thru 3'-4 rod TL pecify ' Material: Steel s Length Function: Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specifyFig. B3205L when ordering. Size Maximum Temperature: 750°F (399°C) Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and " \- Thread materials. Order By: Figure number, rod size, length and finish Standard Design Load Thread Size Thread Length TI 650°F (343°C) 750°F (399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 x "1" 3/g"-16 21/2 (63.5) 730 (3.25) 572 (2.54) 1 B3205-1/2 x1 1/2'_13 21/2" (63.5) 1350 (6.00) 1051 (4.70) x .1, /8'-11 21/2' (63.5) 2160 (9.61) 1692 (7.52) B3205-314 X '1" /4'-10 3 (76.2) 3230 (14.37) 2530 (11.25) I B3205-718 x 'I, 7/'_9 31/2' (88.9) 4480 (19.93) 3508 (15.60) 1 For larger sizes consult full line pipe hanger catalog. AIR - All Threaded Rod - 120" (3.05m) Lengths (TOLCO Fig. 100) Fig. 99 - All Threaded Rod Cut To Length Size Range: /8'-16 thru 11/2'6 rod in 120" lengths or cut to length Material: Steel Maximum Temperature: 750°F 1399°C) Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Part No. - Size x Length Threads Recommended Load Approx. Wt./100 Ft. AIR I Fig. 99 1 Per Inch Lbs. (kN) Lbs. (kg) LI'" x 120 99.1/4" x length 20 240 (1.07) - 12 (5,44) ] ATR 3/8" x 120 99.3/8" x length 16 730 (3.24) 29 (13.15) r-ATR'1j?'i_1f0_ 9-'/2"XIiijth 13 1350 (6.00) 53 (24.04i] AIR 5/8" x 120 99-5/8" x length 11 2160 (9.60) 89 (40.37) c,TR3/4 'T2O 99-3I4"'iength 10 3230 (14.37)123(55.19)] AIR 1/8" x 120 1 99_1/g" x length 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line by 0 94 - Revised 4/28/2014 Fire Protection Solutions f ['N 4; Fig, 200-112. 200-/ Fig. 200-21/2 to 200-8 Fig. 200 Fig. 2005 Pipe Hangers ® TOLCtJ C® US LISTED Fig. 200 - Trimline" Adjustable Band Hanger (B-Line Fig. B317ONF) Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B311ONFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily ,' ', B installed around pipe. For hanger with non-captured nut order Fig. 200S. / (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) l/4" (20mm) thru 8" (200mm)). Fig. 200-1 to 200-2 Conforms to Federal Specifications WW-H-1 71 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F 1343°Cl Finish: Pre-Galvanized. Stainless Steel .. materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of Fig. 200C Fig. 200F Pipe Size Rod Size A B Approx. Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200.1/2 1/2" (15) /8'-16 31/8" (79.4) 2/8" (66.7) 11 (5.0) 200-/4 3/4" (20) /8"-16 31/8" (79.4) 21/2' (63.5) 11 (5.0) 200-1 1 (25) . /8"-16 3/8' (85.7) 2/8" (66.7) 12 (5.5) 200.11/4 11/4" (32) /8"-16 33/4' (94.0) 2/8" (73.0) 13 (5.9) 200.11/2 11/2" (40) /8'-16 31/8" (98.4) 2/8" (73.0) 14 (6.4) 200-2 2" (50) /8"-16 41/2' (114.3) 3' (76.3) 15 (6.9) 200.21/2 21/2" (65) 3/8"-16 5/8" (142.9) 41/8' (104.7) 27 (12.3) 200-3 3' (75) /8'-16 5/8" (149.1) 4" (101.6) 29 (13.3) 200-31/2 31/2" (90) /8'-16 73/g' (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) /'-16 1/" (187.3) 5' (127.0) 35 (16.0) 200-5 5" (125) 1/2'13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"13 101/8' (257.2) 6/4' 1171.41 73 (33.4) 200-8 8" (200) 1/2'13 131/8' (333.4) 8/4' (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified B-Line Fire Protection Solutions 21 by E..T'N ®TOLCtJ' us LISTED - B S Fig. 24 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe Double Fastener Strap Side Mounted (Cooper B-Line B3183) Size Range: 3/4 (20mm) thru 2" (50mm) CPVC pipe Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.912mm) steel using (2)1/4" x 10 tek type screws. Meets and exceeds the requirements of NFPA 13,13R and 13D. Features: Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws" furnished with the ) product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to L.4 result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish: Pre-Galvanized Order By: Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. 0* With reduced spacing, consult factory. fl j 24-/4 3/4 (20) 2I16" (58.7) 1/32" (27.8) 1/16' (30.2) 51/2 (1.67) /16" (7.9) 9 (4.1) 24-1 1" (25) 2/8" J1L 1/16" JL 1I16" () 6 (1.83) I16 (7.9) 9 (4.1) 24.11/4 11/4" (32) 3" (76.2) 11/2' (38.1) 1/16" (30.2) 61/2 (1.98) /16" (7.9) 11 (5.0) 24.11/2 11/2 (40) 31/4 (82.5) 1/8" (42.3) Ll/16 (30.2) 7 (2.13) /16" (7.9) 12 (5.4) 24-2 2" (50) 311/16 (93.7) 127/32 (43.6) 1/16" (30.2) 8 (2.44) /16" (7.9) 15 (6.8) Fig. 25 - Surge Restrainer Size Range: - One size fits 3/4" (20mm) thru 2" (40mm) pipe. Material: - Pre-Galvanized Steel Function: - Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUL). Finish: Pre-Galvanized Order By: Figure number and band hanger, size from (20mm) thru 2" (40mm). Patent 415,344,108 c®us LISTED All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified U" .. L . COOPER B-Line Anvil Cast Iron & Malleable Iron Threaded Fittings Manufactured in Columbia, PA USA, Anvil offers the most complete line of Cast Iron and Malleable Iron Threaded Fittings in the industry. Our versatile range of fittings is designed to provide connection options for different applications and environments. Cast Iron (Gray Iron) Threaded Fittings are manufactured in accordance with ASME/ANSI B 14.4 and are UL/ULC listed and FM approved. Malleable Iron Fittings are manufactured in accordance with ASME/ANSI B16.3 and Unions ASME/ANSI B16.39 and are available in Class 150, Class 250, and Class 300 ULJULC listed and FM approved. In both classes, all Elbows and Tees /e" and larger are 100% air tested at a minimum of 100 psi (6.9 bar). Cast Iron Flanged Fittings are manufactured in accordance with ASME B16.1 and are available in both Class 125 and Class 250. 'V Anvil Steel Pipe Nipples & Steel Pipe Couplings Anvil offers a variety of Steel Pipe Nipples and Steel Pipe Couplings for standard nipple packs ranging from one each (close to 6") and the fire protection industry, standard six packs which offer multiple counts of each. Cartons are packed with handles for easy carrying. Anvil's Steel Pipe Nipples are manufactured in accordance with ASTM/ ANSI A 733 welded and seamless carbon steel pipe nipples. Materials Steel Pipe Couplings are manufactured in accordance with ASTM include black and hot-dipped galvanized finishes. Anvil manufactures a specification A 865. Straight-tapped couplings range in size from 1/8 wide range of stock pipe nipples in 1/80 diameter through 8' diameter NPS through 2" NPS, while 21h" NPS and larger are taper tapped. close through 72' inch length in half-inch increments. We also offer (C's_'OR~F/RwL SPF Ductile Iron & Cast Iron Threaded Fittings SPF Ductile Iron Threaded Fittings are UL/ UIC Listed and FM Approved for 500 psi service. These fittings provide a dependable threaded connection and are available in a range of styles and specifications. All SPF Ductile Iron Threaded Fittings dimensions conform to ANSI B16.3 Class 150 require- ments, and threads are NPT per ANSI/ASME B 1.20.1. SPF Cast Iron Threaded Fittings are UL/ULC Listed and FM Approved for 300 Psi service. These fittings are available in a range of styles and specifications. All SPF Cast Iron Threaded Fittings dimensions conform to ANSI 1316.4 requirements, and threads are NPT per ANSI/ASME 131.20.1 Ni4oIJuu www.anvilintl.com Fire Products 3