HomeMy WebLinkAbout2668 GATEWAY RD; ; FPC2018-0165; PermitPERMIT REPORT C(Ility of Carlsbad Print Date: 10/18/2021 Permit No: FPC2018-0165 Job Address: 2668 GATEWAY RD, CARLSBAD, CA 92009-1774 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: UPTOWN BRESSI RANCH Description: UPTOWN BRESSI BUILDING G -SPRINKLER (113 HEADS) Fire Sprinklers Applied: 05/30/2018 Issued: DEV12023 Finaled Close Out: 05/26/2021 Inspector: Final Inspection: Applicant: FPContractor: LINDLEY FIRE PROTECTION LINDLEY FIRE PROTECTION CO INC-DO NOT JAVIER MEJIA USE 2220 E VIA BURTON 1109 N ARMANDO ST ANAHEIM, CA 92806-1221 ANAHEIM, CA 92806-2609 (714) 984-4150 (714) 535-5761 FEE AMOUNT FIRE NFPA 13 System> 100 heads (includes 1 riser) $832.00 Total Fees: $832.00 Total Payments To Date: $832.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov 0(0 Co J CL U. co co C cog > U 04 D - - - Fire Protection by Computer Design LINDLEY FIRE PROTECTION 2220 E. VIA BURTON ANAHEIM, CA 92806 714-535-5761 Job Name : THE SQUARE AT BRESSI RANCH BLDG G TOWER LI\ Building : G Location : 2668 GATEWAY ROAD System : 1 Contract : A3001 Data File : The Square at Bressi Ranch Bldg G Tower.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 LINDLEY FIRE PROTECTION Page THE SQUARE AT BRESSI RANCH BLDG G TOWER Date 6-8-18 Hydraulic Design Information Sheet Name - THE SQUARE AT BRESSI RANCH BLDG G TOWER Date - 6-8-18 Location - 2668 GATEWAY ROAD Building - G System No. - 1 Contractor - CSI CONTRUCTION COMPANY Contract No. - A3001 Calculated By - T. OMORI Drawing No. - FPG2.1 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 35'-8" Occupancy - S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 1500 System Type Sprinkler/Nozzle Density - .10 (X) Wet Make GLOBE D Area Per Sprinkler - 109 ( ) Dry Model GL E Elevation at Highest Outlet - 341 -8° ( ) Deluge Size 1/2 S Hose Allowance - Inside - 100 ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.200 G Hose Allowance - Outside - N Note Calculation Flow Required - 180.29 Press Required - 108.46 BOR Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 3-9-18 Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - 129 @ Press - R Residual Press - 20 Elev. - Well Flow - 8000 Proof Flow S Elevation - U P Location - EL FUERTE STREET NORTH OF GATEWAY ROAD P L Source of Information - CITY OF CARSBAD Y C Commodity Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack M Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C LINDLEY FIRE PROTECTION Page 2 THE SQUARE AT BRESSI RANCH BLDG G TOWER Date 6-8-18 City Water Supply: Demand: Cl - Static Pressure : 129 Dl - Elevation : 15.014 C2 - Residual Pressure: 20 D2 - System Flow :180.291 C2 - Residual Flow : 8000 D2 - System Pressure :113.994 Hose ( Demand) :100 D3 - System Demand : 280.291 Safety Margin : 14.785 150 140 Cl 130 p120 R1'° E 100 90 - 80 u 70 R 60 E5° 40 -- 30 - C2 20 10 lOFercenti .1 nder. I 10002000 3000 4000 5000 6000 7000 8000 9000 FLOW ( N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram LINDLEY FIRE PROTECTION THE SQUARE AT BRESSI RANCH BLDG G TOWER 25.9 78.1 101<- 102<- 103<- 110 51.8 I I 102.2 25.4 I 104<- 105<-. 108 51 I 25 76 . 180.3 180.3 180.3 180.3 280.3 280.3 132.4 106 <- 107*- 108<- 109 <- 110<- 111 <- 112<- 113<- 23 <-24 <-TRG<-- BRG- GI <-G2 <-G3 <-UG6<-- UGS*- UG4E- UG9 25 102.2 180.3 180.3 180.3 280.3 280.3 132.4 132.4 147.9 147.9 UG6<- UG7<- UG8<- UG9<- CON 147.9 280.3 Page 3 Date 6-8-18 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary LINDLEY FIRE PROTECTION Page 4 THE SQUARE AT BRESSI RANCH BLDG G TOWER Date 6-8-18 Fitting Legend Abbrev. Name % 3/4 1 1% 1% 2 2% 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 1345Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 I NFPA 139OFlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zif Febco 876V Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD LINDLEY FIRE PROTECTION Page 5 THE SQUARE AT BRESSI RANCH BLDG G TOWER Date 6-8-18 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 101 34.667 5.6 21.33 na 25.86 0.1 109 20.0 102 34.667 5.6 21.48 na 25.95 0.1 109 20.0 103 34.667 5.6 22.02 na 26.28 0.1 109 20.0 104 34.667 5.6 20.64 na 25.44 0.1 109 20.0 105 34.667 5.6 20.78 na 25.53 0.1 109 20.0 106 34.667 5.6 20.0 na 25.04 0.1 109 20.0 107 34.667 20.48 na 108 34.667 20.82 na 109 34.667 5.6 21.86 na 26.18 0.1 109 20.0 110 34.667 26.22 na 111 34.667 27.65 na 112 34.667 32.44 na 113 34.667 86.99 na 23 34.667 87.66 na 24 34.667 89.95 na TRG 34.667 90.34 na BRG 0.0 108.46 na 100.0 Gi 0.0 108.53 na G2 0.0 108.7 na G3 0.0 113.62 na UG6 0.0 113.86 na UGS 0.0 113.88 na UG4 0.0 113.93 na UG7 0.0 113.9 na UG8 0.0 113.93 na UG9 0.0 113.97 na CON 0.0 113.99 na The maximum velocity is 24.33 and it occurs in the pipe between nodes 112 and 113 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final *Calculations - Hazen-Williams LINDLEY FIRE PROTECTION Page 6 THE SQUARE AT BRESSI RANCH BLDG G TOWER Date 6-8-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. .1c'.or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 101 25.86 1.74 0.0 8.500 21.325 K Factor = 5.60 to 120.0 0.0 0.0 0.0 102 25.86 0.0179 0.0 8.500 0.152 Vel = 3.49 102 25.95 1.74 0.0 8.500 21.477 K Factor 5.60 to 120.0 0.0 0.0 0.0 103 51.81 0.0644 0.0 8.500 0.547 Vel = 6.99 103 26.28 1.74 E 5.838 13.000 22.024 K Factor = 5.60 to 120.0 T 11.677 17.515 0.0 110 78.09 0.1376 0.0 30.515 4.198 Vel = 10.54 0.0 78.09 26.222 KFactor= 15.25 104 25.44 1.74 0.0 8.500 20.638 K Factor = 5.60 to 120.0 0.0 0.0 0.0 105 25.44 0.0172 0.0 8.500 0.146 Vel = 3.43 105 25.53 1.74 0.0 0.500 20.784 K Factor = 5.60 to 120.0 0.0 0.0 0.0 108 50.97 0.0640 0.0 0.500 0.032 Vel = 6.88 0.0 50.97 20.816 KFactor= 11.17 106 25.04 1.087 E 2.378 0.500 20.000 K Factor = 5.60 to 120.0 0.0 2.378 0.0 107 25.04 0.1657 0.0 2.878 0.477 Vel = 8.66 107 0.0 1.65 T 9.016 6.542 20.477 to 120.0 0.0 9.016 0.0 108 25.04 0.0218 0.0 15.558 0.339 Vel = 3.76 108 50.97 1.74 0.0 8.000 20.816 to 120.0 0.0 0.0 0.0 109 76.01 0.1308 0.0 8.000 1.046 Vel = 10.26 109 26.19 1.74 E 5.838 1.750 21.862 K Factor 5.60 to 120.0 1 11.677 17.515 0.0 110 102.2 0.2263 0.0 19.265 4.360 Vel = 13.79 110 78.09 2.215 E 7.002 0.167 26.222 to 120.0 0.0 7.002 0.0 111 180.29 0.1996 0.0 7.169 1.431 Vel = 15.01 111 0.0 2.215 E 7.002 17.000 27.653 to 120.0 0.0 7.002 0.0 112 180.29 0.1997 0.0 24.002 4.792 Vel = 15.01 112 0.0 1.74 2E 11.677 37.625 32.445 to 120.0 3T 35.03 46.707 0.0 113 180.29 0.6467 0.0 84.332 54.541 Vel = 24.33 113 0.0 3.316 T 21.903 2.333 86.986 to 120.0 0.0 21.903 0.0 23 180.29 0.0280 0.0 24.236 0.678 Vel = 6.70 23 0.0 3.316 E 10.221 67.000 87.664 to 120.0 F 4.381 14.602 0.0 24 180.29 0.0280 0.0 81.602 2.283 Vel = 6.70 24 0.0 3.316 E 10.221 3.792 89.947 to 120.0 0.0 10.221 0.0 TRG 180.29 0.0280 0.0 14.013 0.392 Vel = 6.70 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams LINDLEY FIRE PROTECTION Page 7 THE SQUARE AT BRESSI RANCH BLDG G TOWER Date 6-8-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C',or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn TRG 0.0 4.316 Fsp 0.0 13.833 90.339 to 120.0 0.0 0.0 18.014 * * Fixed Loss = 3 BRG 180.29 0.0077 0.0 13.833 0.107 Vel = 3.95 BRG 100.00 6.357 E 17.603 10.000 108.460 Qa = 100 to 120.0 0.0 17.603 0.0 GI 280.29 0.0027 0.0 27.603 0.074 Vel = 2.83 Gi 0.0 6.09 2E 43.166 32.000 108.534 to 150.0 0.0 43.166 0.0 G2 280.29 0.0022 0.0 75.166 0.163 Vel = 3.09 G2 0.0 6.16 Zif 0.0 10.000 108.697 to 140.0 0.0 0.0 4.900 * * Fixed Loss = 4.9 G3 280.29 0.0023 0.0 10.000 0.023 Vel = 3.02 G3 0.0 6.09 G 4.625 18.000 113.620 to 150.0 T 46.249 94.040 0.0 UG6 280.29 0.0022 2F 21.583 112.040 0.243 Vel = 3.09 E 21.583 UG6 -147.86 7.98 3F 40.774 94.000 113.863 to 150.0 0.0 40.774 0.0 UG5 132.43 0.0001 0.0 134.774 0.020 Vel = 0.85 UG5 0.0 7.98 E 27.183 234.500 113.883 to 150.0 F 13.591 99.669 0.0 UG4 132.43 0.0001 G 6.041 334.169 0.048 Vel = 0.85 T 52.855 UG4 0.0 7.98 F 13.591 233.000 113.931 to 150.0 2G 12.081 25.674 0.0 UG9 132.43 0.0001 0.0 258.674 0.038 Vel = 0.85 0.0 132.43 113.969 KFactor= 12.40 UG6 147.86 7.98 2F 27.183 187.000 113.863 to 150.0 0.0 27.182 0.0 UG7 147.86 0.0002 0.0 214.182 0.038 Vel = 0.95 UG7 0.0 7.98 2F 27.183 124.500 113.901 to 150.0 0.0 27.182 0.0 UG8 147.86 0.0002 0.0 151.682 0.027 Vel = 0.95 UG8 0.0 7.98 F 13.591 155.000 113.928 to 150.0 G 6.041 72.487 0.0 UG9 147.86 0.0002 T 52.855 227.487 0.041 Vel = 0.95 UG9 132.43 11.65 2F 34.882 138.000 113.969 to 150.0 2G 16.1 131.481 0.0 CON 280.29 0.0001 T 80.498 269.481 0.025 Vel = 0.84 0.0 280.29 113.994 K Factor= 26.25 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: The Square at Bressi Ranch SR#: (Assigned upon plan submittal) PROJECT ADDRESS: CITY: Carlsbad PHONE: ( ) Lindley Fire FAX NUMBER: Largest Building (ft.2): Sprinkled? Construction Type: SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): El Fuerte St north of Gateway Rd Flow Test Results Static pressure: 129 PSI Hydrant Number (if applicable): H20910 Elevation of test: .402 Feet Main Size: 24 INCH Pressure Zone: 700 Feet Fat Total Flow: 81000 GPM Residual Pressure 110 PSI At peak demand, this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: Name- Jennifer R. Mael, P.E. Eng. Lic. No. (if applicable): C69606 Signature: . 1' Title/ Org: Proiect Manager ate. / - f I Legend - - lb Pipe t ZONE ii8fl H iI: Fire Flow Test Location H20910 Projecttsitj ZW &*WGTOK WY 8. CA 4 CO The Square at Bressi Ranch - Fire Flow Analysis Job Name Job Location Engineer - Approval - MasterSeries® LF876V Double Check Detector Backflow Prevention Assemblies (Type II) Size: 21/2" - 8" (65mm - 200mm) The FEBCO MasterSeries LF876V Double Check Detector Assembly is specifically designed to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application in accordance with Local Governing Water Utility Code. This Backflow Assembly is primarily used on potable drinking water systems and fire sprinkler systems, where Local Governing Code mandates protection from non-potable quality water being pumped or siphoned back into the potable water system. Features Main Valve: Inline Serviceable Assembly Horizontal "N-Pattern" Installations Vertical-Up "Z-Pattern" Installations No Special Tools Required for Servicing Captured Modular Spring Assembly Reversible & Replaceable Discs Field Replaceable Seats Ductile Iron Valve Body Design Stainless Steel Check Components Winterization feature with disc retainers and valve body drain ports Clapper Check Assembly Commonality between 1St & 2nd Check Components Captured 0-ring Design Auxiliary Bypass: Compact Bypass Design; Remains within Main Valve Assembly Profile Inline Serviceable 3/4 Backflow Assembly Contractor Approval Contractor's P.O. No. Representative Model LF876V Double Check Detector Assembly Specifications The FEBCO MasterSeries LF876V Double Check Detector Valve Assembly shall be installed on the potable water supply and at each point of cross-connection to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) applications. The assembly shall consist of a main line valve body composed of two (2) independently acting approved clapper style check modules with replaceable seats and disc rubbers. Servicing of both check modules does not require any special tools and are accessed through independent top entry covers. This assembly shall be fitted with approved UL/ FM inlet/outlet resilient seated shutoff valves and contain four (4) properly located resilient seated test cocks as specified by AW.AJA Standard C51 0. The auxiliary bypass line contains a %04' Water Meter that complies with ANSI/A\MNA Standard C700 coupled with an approved check assembly. The bypass line is designed to detect leaks or unauthorized water usage of the water system while protecting against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application. The assembly shall be approved for horizontal and/or vertical-up installations while meeting the requirements of A\MNA Standard C51 0 flow and pressure loss performance parameters. NOTICE I The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. No Special Tools Required for Servicing MKITUMM Field Replaceable Seats & Discs Inquire with governing authorities for local installation requirements Detect Potential Underground Water Leaks "The wetted surface of this product contacted by consumable Detect Unauthorized Water Usage water contains less than 0.25% of lead by weight. FEBCO product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact FEBCO Technical Service. FEBCO reserves the right to change or modify product design, construction, specifications, or materials with- out prior notice and without incurring any obligation to make such changes and modifications on FEBCO products previously or subsequently sold. A WATTS Brand Options - Suffix OSY: UL/FM Approved OS&Y Gate Valves [ANSI!AWWA 0515 Compliant] CFM: Totalizing Cubic feet/mm 5/8"x 3/4" Water Meter [ANSI/ A\MNA 0700 Compliant] GPM: Totalizing Gallons/mm 5/8"x 3/4" Water Meter [ANSI! A\MNA 0700 Compliant] LG: Less Shutoff valves; This is NOT an APPROVED ASSEMBLY Example Ordering Description: 4" LF876V-OSY-GPM - Valve Assembly fitted with OS&Y Shutoff Valves & Gallons per Minute Water Meter 4" LF876V-OSY-CFM - Valve Assembly fitted with OS&Y Shutoff Valves & Cubic Feet per Minute Water Meter Available Components Wye Strainer. FDA Approved [ASME B16.1 Class 125 & AV\ANA Class D Flange] Series 611 Valve Setter: MJ x MJ - Mechanical Joint x Mechanical Joint [AVWAC111/A21.11] MJ x FL - Mechanical Joint x Flange ]A'MNAC111!A21.11; ASME B16.1 Class 1 25!AW\NA Class D Flange] FL x FL - Flange x Flange [ASME Bi 6.1 Class 125 & A\W/A Class 0 Flange] Materials Below is a general materials list of the Model LF876V. All assemblies size 21/2" through 8' is similar in materials and construction. Please contact your local FEB00 Representative if you require further information. Main Valve Body: Ductile iron Grade 65-45-12 Coating: Fusion epoxy coated internal and external A\MNA 0550-90 Approvals - Standards: Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California [F000HR-USC] ASSE 1048 Listed **UL Classified [US & Canada] **FM Approved lAPMO!cUPC AV\M/A Standard 0510 Compliant End Connections: Compliant to ASME B16.1 Class 125 & A\MNA Class D Flange **Assembly configured with UL/FM Approved OS&Y RW Gate Valves. Less gate valve assemblies are not UL/FM approved configurations. Assembly Flow Orientation: Horizontal (N-Pattern 21/2 - 8") - Approved by F000HR-USC, ASSE, cULus, FM, IAPMO!cUPC Vertical Up (Z-Pattern 21/2' - 8") - Approved by FCCCHR-USC, ASSE, cULus, FM, lAPMO/cUPC ® SSIp Approved C®US C ® 1048 B64.5 Pressure - Temperature Max. Working Pressure: 175p51 (12.1 bar) Mm. Working Pressure: lOpsi (0.7 bar) Hydrostatic Test Pressure: 350psi (24.1 bar) Hydrostatic Safety Pressure: 700psi (48.3 bar) Temperature Range: 33°F - 140°F [0.5°C- 60°C] Continuous Shutoff Valves: Check Seats: Disc Holder: Elastomer Disc: Spring: Clamp: OSY resilient wedge gate valve A\MNA 0515 (UL/FM) Stainless Steel Stainless Steel Silicone Stainless Steel AW/A 0606 Dimensions - Weights Size: 21/211 - 81 Below are the nominal dimensions and physical weights for the Model LF876V size 2112' through 8. Allowances must be made for normal manufacturing tolerances. Please visit our website to download a copy of this product's installation instructions, or contact your local FEB00 Representative for more information. Model LF876V Standard Orientation (N-Pattern) Model LF876V Vertical Orientation (Z-Pattern) Note: The Series LF876V is shipped in the standard (N-Pattern) orientation as shown above. Gate Valve Side View Clearance LF876V SIZE (ON) DIMENSIONS WEIGHT in. mm A in, mm B in. mm c in. mm 0 in. mm E in. mm F in. mm in. G mm in. H mm in. I mm J in. mm K* in. mm in. L mm OSY ft.kg. 21/2 65 291/8 740 121/2 318 61/4 159 251/4 642 171/2 445 135A 346 271/4 692 51/2 140 11½ 283 31/2 89 16/8 416 111/2 292 216 98 3 80 291A 740 121h 318 61/4 159 253/4 654 17/4 451 141/8 359 281/4 718 51/2 140 111/8 283 33/4 95 221/4 565 11½ 292 242 110 4 100 311/8 791 14 356 7 178 273/4 705 183/4 476 151/2 394 31 787 6 152 111/8 283 41/2 114 23'/4 591 13 330 347 157 6 150 353/4 908 16 406 8 203 323/4 831 221h 562 185/8 473 371/4 946 71/4 184 121/2 316 51/2 140 301/8 765 13 330 529 240 8 200 1 403/4 1035 181/2 470 91/4 235 1 363/4 933 25/8 638 1 20~/4 527 1 411/2 1054 81/, 216 14 356 63/4 172 1 373/4 959 141/2 368 1 827 375 Notes: * Indicates nominal dimensions with OSY Gate Valves (Full Open Position) ** Indicates weight of complete Backf low Assemblies with specified Gate Valves 6" 1F876V psi Service Flow Rated Flow "UL Rated Flew 18 16 14 I I I I I 8 12 I I 10 I I I 8 I I I — 2 0 I I I I I I 0 200 400 757 600 800 1000 1200 2271 3785 7.5 11.4 1400 1600 gpm 5300 1pm 17.0 fps 8" 1F876V PSI Service Flow Rated Flew UL Rated Flow 18 16 14 12 10 8 0 400 800 1200 1600 2000 2400 gpm 1514 3028 4543 6057 7571 9085 1pm 7.5 10.5 15.3 fps Performance Flow capacity chart identifies valve performance based upon rated water Velocity up to 20fps Maximum service flow rate is determined by maximum rated Velocity of 7.5fps. A\/V\NA Manual M-22 (Appendix C) recommends that the maximum water Velocity in the services be not more than lOfps. UL flow rate is determined by typically rated Velocity of 15 feet/sec. Capacity N-Pattern 21/20 1F876V PSI Service Flow -Pattern Rated Flow *UL Rated Flow 22 20 I I 18 i I E 14 I 12 I I r—I iaVi I TTr 0 25 50 75 284 1F876V psi 100 125 150 175 200 225 250 275 300 325 350gpm 568 852 1136 1pm 7.5 14.7 22.0 fps Service Flew Rated Flow *UL Rated Flow 22 20 I I I 18 I I I 5 16 I I I 14 12 I I I g 10 I I I I 6 4 I I I 2 I I I 0 I I 0 50 100 379 1F876V psi 150 200 757 7.5 Service Flow 250 300 350 1136 14.5 Rated Flow 400 450 500 gpm 1514 1pm 22.0 fps *UL Rated Flow 18 16 I I I I 14 I I 10 2 I 6 ---_ -----_-----T -I I I I 2 I I I 0 I I I I I 0 100 200 300 379 1136 7.5 400 500 600 1893 12.8 700 800gpm 2650 1pm 19.1 fps Pipe Support (furnished by customer) for valve weight only. Vertical Orientation"Z-Pattern" Flow Curve Z Standard Oentation"N-Pattern" Flow Curve N A WATTS Brand ES-F-LF876V 1515 USA: Tel: (800) 767-1234 • Fax: (800) 788-4491 • FEBCOonhine.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • FEBCOonhine.ca Latin America: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • FEBCOonline.com © 2017 FEBCO cl c4il LINDLEY FIRE PROTECTION CO. af 2220 E. VIA BURTON ANAHEIM, CA 714-535-5761 LIC. # C16104 NO. 713562 co DATE: 4-27-18 co co C) N 0 Qco a MATERIAL SUBMITTAL FOR THE SQUARE AT BRESSI RANCH BUILDING G 2668 GATEWAY ROAD CARLSBAD, CA GLb'"MAWBE FIRE SPRINKLER CORPORATION STANDARD RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Standard Response CL Series Sprinklers are a low profile yet durable design which utilizes a 5mm frangible glass ampule as the thermosensitive element. While the Standard Response Sprinkler provides an aesthetically pleasing appear- ance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and fin- ishes to meet varying design requirements. Standard Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's CL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. The sprinkler and escutcheon are not factory assembled. Assembly is done in the field. TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (57°C), 155°F (680C), 175°F (79°C), 200°F (930C), 286°F (141°C), 360°F (182°C) 500°F (260°C) Available Upon Request Without Approvals Water Working Pressure Rating -175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -67°F (-55°C) Frame - bronze • Deflector - brass • Screw - brass Lodgement Wire - stainless steel • Bulb seat - copper Spring - nickel alloy • Seal - teflonw Bulb - glass with glycerin solution, 5mm size Escutcheon Assembly - steel SPRINKLER TEMPERATURE RATING/CLASSIFICATION AVAILABLE SPRINKLER CLASSIFICATION BULB COLOR TEMPERATURES COLOR COD N.F.P.A. MAXIMUM CEILING TEMPERATURE ORDINARY INTERMEDIATE HIGH EXTRA HIGH 'ULTRA HIGH ORANGE/RED YELLOW/GREEN BLUE MAUVE BLACK NOV 2016 GFS-100b (Formerly A-65) STANDARD RESPONSE UPRIGHT CONVENTIONAL ___ ---- - STANDARD RESPONSE PENDENT VERTICAL SIDEWALL ;. STANDARD RESPONSE LPC/CE HORIZONTAL HORIZONTAL SIDEWALL SIDEWALL -2 15/16' DIA. 2" DIA. MIN. HOLE IN CEILING 29/32' 25.4mm X 12.7mm I IT 1/2 REDUCER 50.8mm DIA. MIN. I HOLE IN CEILING 74.6mm UC S. DIA. I I I MM F 7fB" 1/8" . I I I 1" MIS. 13/4" MAX, STANDARD RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT • PENDENT • VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL 'K' FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (40 metric) 1/2"NPT(15mm) 2 1/4°(5.7cm) Factory Bronze 4.2 (60 metric) 1/2"NPT(15mm) 21/4" (5.7cm) Chrome 5.6 (80 metric) 1/2'NPT(15mm) 21/4" (5.7cm) White Polyester3 8.0 (115 metric) 1/2"NPT(15mm) 2 1/4" (5.7cm) Black Polyester23 8.0 (115 metric) 314"N PT (20mm) 2 7/16" (6.2cm) Wax Coated 2.3.4 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'AVAILABLE AS cULus LISTED COROSION RESISTANT WHEN SPECIFIED ON ORDER. 'HORIZONTAL SIDEWALL IS 9/16". 'WAX COATING cULus LISTED UP TO 200°F (93°C) ONLY. 'FINISHES AVAILABLE ON SPECIAL ORDER. APPROVALS TEMPERATURE STYLE SIN MODEL K FACTOR HAZARD cULus FM LPC CE NYC-DOB MEAIOI-92-E 135°F 155°F 175°F 200°F **2860F "360°F (57°C) (68°C) (79°C) (93°C) (141°C) (182°C) GL2861 2.8 LH X X X X X X X X GL4261 4.2 LH X X X X X X X x UPRIGHT GL5661 5.6 ALL X X X X X X X X X X X GL8161 8.0 ALL X X X X X X X x GL8164 8.0 ALL X X X X X X X X X X X GL2851 2.8 LH X X X X X X X X PENDENT GL4251 4.2 LH X X X X X X X X RECESSED GL5651 5.6 ALL X X X X X X X X X X X PENDENT GL8151 8.0 ALL X X X X X X X X X GL8156 8.0 ALL X X X X X X X X' X X X VERTICAL GL5675 5.6 LH X X X X X X X X SIDEWALLt GL8176 8.0 LH X X X X X X X HORIZONTAL GL2870 2.8 LH X X X X X X X X SIDEWALL GL4270 4,2 LH X X X X X X X X RECESSED GL5670 5.6 LH/OH X X X X X X X X HORIZONTAL GL5671D 5.6 LH/OH X X X X X X --- --- X X SIDEWALL GL8171 8.0 LH/OH X X X X X X X -X --- CONVENTIONAL GL5668 5.6 LH/OH X X X X X X --- --- X X (OLD STYLE) GL8169 8.0 LH/OH X X X X X X --- --- X X 'SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA1 3 AND ANY OTHER RELATED DOCUMENTS. 'BRASS FINISH ONLY WHEN RECESSED §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. ""No FM APPROVALS FOR RECESSED DINSTALL IN ACCORDANCE TO B55306 AND ANY OTHER RELATED DOCUMENTS. "NO FM APPROVALS tPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. OH: ORDINARY HAZARD tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. LH: LIGHT HAZARD 500°F (260°C) AVAILABLE UPON REQUEST WITH NO APPROVALS. ALL: ALL HAZARDS 7/8" MAX. __________ ORDERING INFORMATION SPECIFY Quantity. Model • Number Style. Orifice Thread Size • Temperature. Finish desired ° Quantity - Wrenches/Recessed Wrenches - P/N 325390/325391 (1/2"); P/N 312366/325401 (L.O.) ° Quantity Protective Caps - P/N 327109-CAP (Friction Fit Recessed) -3.2mm 3.2mm MIN. 12.2.m MAX. GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). SEE 0801E 25.4mm MIS 44.5mm MAX 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 GIBE 989-846-4583 FAX 989-846-9231 FIRE SPRINKLER CORPORATION 1-800-248-0278 www.globesprinkler.com NOV 2016 PRINTED U.S.A. GFS-100b (Formerly A-65) QUICK RESPONSE UPRIGHT CONVENTIONAL 21 QUICK RESPONSE PENDENT VERTICAL SIDEWALL 5FA kv GL mmou 6~"FIFJ BE FIRE SPRINKLER CORPORATION QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT S PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable stan- dards. It offers the additional feature of greatly increased safe- ty to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuat- ing assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is ab- sorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distrib- uted in an approved pattern depending upon the deflector style used. TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (570C), 155°F (680C), _ -• 175°F (790C), 200°F (93°C), 286°F (141°C) Water Working Pressure Rating -175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -67°F (-55°C) Frame - bronze • Deflector - brass • Screw - brass Lodgement Wire - stainless steel • Bulb seat - copper Spring - nickel alloy • Seal - teflon Bulb - glass with alcohol based solution, 3mm size QUICK RESPONSE HORIZONTAL LPC/CE SIDEWALL HORIZONTAL SIDEWALL 'SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING NOV 2016 GFS-looa (Formerly A-20) QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (40 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) 4.2 (60 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Factory Bronze 5.6 (80 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Chrome White Polyester 3 8.0 (115 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Black Polyester 2,1 8.0 (115 metric) I 3/4"NPT (20mm) 27/16" (6.2cm) NOTE: METRIC KI(. ONVENSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9/16". 'FINISHES AVAILABLE ON SPECIAL ORDER. 'AVAILABLE AS cULus LISTED COROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS TEMPERATURE STYLE SIN MODEL K FACTOR HAZARD' cULus FM LPC CE NYC - DOB MEA 101-92-E 135°F 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) GL2815 2.8 LH X X X X X X X GL4215 4.2 LH X X X X X X X UPRIGHT GL5615 5.6 LH/OH X X X X X X X X X X GL8115 8.0* LH/OH X X X X X X X GL8118 8.0 LH/OH X X X X X X X X X X GL2801 2.8 LH X X X X X X X GL4201 4.2 LH X X X X X X X PENDENT GL5601 5.6 LH/OH X X X X X X X X X X GL8101 8.0* LH/OH X X X X X X X X GL8106 8.0 LH/OH X X X X X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X SIDEWALLt GL8133 8.0 LH X X X X X X --- GL2826 2.8 LH X X X X X X X HORIZONTAL GL4226 4.2 LH X X X X X X X SIDEWALL GL5626 5.6 LH/OH X X X X X X X X GL5627a 5.6 LH/OH X X X X X --- --- X X GL8127 8.0 LH/OH X X X X X X CONVENTIONAL GL5624 5.6 LH/OH X X X X X --- --- X X (OLD STYLE) GL8125 8.0 LH/OH X X X X X --- --- X X 'SPRINKLERS SHALL BE LIMITED EL) AS PER THE REQUIREMENTS OF NFPA1 3 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. aINJSTALL IN ACCORDANCE TO B55306 AND ANY OTHER RELATED DOCUMENTS. tPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. OH: ORDINARY HAZARD LH: LIGHT HAZARD °1/2" NPT ORDERING INFORMATION GLOBE® PRODUCT WARRANTY SPECIFY Globe agrees to repair or replace any of its own manufactured Quantity ' Model Number . Style Orifice products found to be defective in material or workmanship for a 'Thread Size . 'Temperature Finishes desired period of one year from date of shipment. Quantity - Wrenches - P/N 325390 (1/2"); For specific details of our warranty please refer to Price List P/N 312366 (L.O.) Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 - 989-846-4583 FAX 989-846-9231 GL68E 1-800-248-0278 www.gIobesprinkIer.com FIRE SPRINKLER CORPORATION NOV 2016 PRINTED U.S.A. GFS-100a (Formerly A-20) FM Approved and Fully Listed Sprinkler Pipe Wheatland's Mega-Flow steel fire sprinkler pipe is FM Approved for roll-grooved, plain-end and welded joints for wet systems; and UL, C-UL and FM Listed for use with roll-grooved, plain- end couplings and welded joints for wet, dry preaction and deluge systems. Mega-Thread is FM Approved for use in wet systems and is UL, C-UL and FM Listed for wet, dry and preaction sprinkler systems. Approvals and Specifications Both products meet or exceed these standards: ASTM A795, Type E, Grade A NFPA 13 and NFPA 14 Mega-Thread is approved for standard hanger spacing Manufacturing Protocols Mega-Flow and Mega-Thread are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings Mega-Flow black steel fire sprinkler pipe receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outlasts standard lacquer coatings. This coating allows the pipe to be easily painted without special preparation. Mega-Thread is hot-dip galvanized to meet FM requirements for dry systems and is safer to weld than many zinc-coated, light-wall threadable products. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. MEGA-FLOW SPECIFICATIONS NPS NOM OD NOM ID UL CRR* MEGA-FLOW Mega-Flow Schedule Schedule Mega-Flow Schedule ni 1 10 40 Pcs./Llft 11% 1.660 1.530 1.442 1.380 1.80 1.00 1.108 61 11/2 1.900 1.740 1.682 1.610 2.64 1.00 1.556 61 2 2.375 2.215 2.157 2.067 2.14 1.00 1.961 37 21/2 2.875 2.707 2.635 2.469 1.43 1.00 2.504 30 3 3.500 3.316 3.260 3.068 1.34 1.00 3.349 19 4 4.500 4.316 4.260 4.026 1.00 1.00 4.331 19 6 6.625 6.395 6.357 6.065 .75 1.00 8.000 10 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). MEGA-THREAD SPECIFICATIONS NPS NOM OD NOM ID UL CRR* MEGA-THREAD Mega-Thread Schedule Mega-Thread Schedule L.W.T. Pipe Nominal Pcs./Llft 1 1.315 1.087 1,049 1.00 1.00 .61 1.462 70 1¼ 1.660 1.416 1.380 1.00 1.00 .39 1.989 51 11/2 1.900 1.650 1.610 1.00 1.00 .31 2.370 44 2 2.375 2.117 2.067 1.00 1.00 .25 3.094 30 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). (9) C@ <~,~.OV>ED PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: 0 MEGA-FLOW-BLACK 0 MEGA-THREAD-HOT-DIP GALVANIZED Wheatland Tube JMC STEEL GROUP SCHEDULE 10 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES In. mm In. mm In. mm Ibs./ft. kg/rn CRR Lift 11/4 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 11/2 1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4,7 37 2'/ 2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 4 4.500 114.3 4.260 108.2 .120 3.05 5.62 8,37 1.6 19 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 6 6.625 168.3 6.357 161.5 .134 3.40 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VlZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). SCHEDULE 40 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES in. mm In. mm In. mm lbs./ft. kg/rn CRR Lift 1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 11/4 1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 1/a 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 2 2.375 60.3 2.067 62.5 .154 3.91 3.66 5.45 1.00 30 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). @ C@ <A~PPROVED FM Approved and Fully Listed Sprinkler Pipe Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, C-UL and FM Listed. Approvals and Specifications Both products meet or exceed the following standards: ASTM A135, Type E, Grade A (Schedule 10) ASTM A795, Type E, Grade A (Schedule 40) NFPA13 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe up to 6" receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black, or with hot-dip galvanizing, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is also UL Listed. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: BLACK 7 HOT-DIP GALVANIZED Wheatland Tube JMC STEEL GPOU lt AwfL tar TM Fire Products Division of Anvil International January 2010 For the most current product/pricing information on Anvil products, pleas visit our website at www,onvilintl.con 4 &MEFR IT Outlet Fittings for Fire Protection B UILDING CONNECTIONS THAT LAST UV4 1€ CNVIL ( Mflj BMW ( I BUILDING CONNECTIONS THAT LAST For over 150 years, Anvil has worked diligently to build a strong, vibrant tradition of making connections - from pipe to pipe and people to people. We pride ourselves in providing the finest-quality pipe products and services with integrity and dedication to superior customer service at all levels. We provide expertise and product solutions for a wide range of applications, from plumbing, mechanical, HVAC, industrial and fire protection to mining, oil and gas. Our comprehensive line of products includes: grooved pipe couplings, grooved and plain-end fittings, valves, cast and malleable iron fittings, forged steel fittings, steel pipe nipples and couplings, pipe hangers and supports, channel and strut fittings, mining and oil field fittings, along with much more. As an additional benefit to our customers, Anvil offers a complete and comprehensive Design Services Analysis for mechanical equipment rooms, to help you determine the most effective and cost-efficient piping solutions for your pipe system. At Anvil, we believe that responsive and accessible customer support is what makes the difference between simply delivering products - and delivering solutions. _~ 0 &ME UT Weld-Miser TM Tee-Let® Welding Outlet Fittings Unified DesignTM Series Merits Unified Design Series carries all important design considerations Into its entire line of welding branch outlet fittings. Merit® WeldMiserThi Tee-1_00 are designed and Manufactured to reduce the amount of weld required to install the Tee-Lets on thin wall or proprietary flow pipe. Typically only one weld-pass completes the Installation. Merit Tee-Lets install with less weld volume than any other brand of welding outlet fittings for fire sprinkler applications. To accomplish this: The contoured end of the fittings employs a reduced outside diameter. Two major advantages are immediately apparent: The thinner wall on the contoured end permits welding temperatures to be matched to the thickness of the branch line or main thereby insuring complete penetration without cold welds, weld roll-off, burn-through or excessive distortion. - - —I- - On smaller sizes a heavier section is maintained on the threaded end of the fitting. This protects the threads from dam- age during shipping and handling prior to installation as well as from weld distortion. Each outlet size 1½" and larger, whether male or female threaded, cut grooved or beveled requires the same hole size in the header pipe. This simplifies the installation process. General Specifications Tee-Let welding outlet fittings are manufactured from highly weldable steel which conforms to the chemical and physical requirements of ASTM A-53, Grades A or B, Type E. Ease of installation is assured when automatic welding equipment is used to install Merit Tee-Lets. Threads are cut In accordance with the requirements of ANSI 131.20.1, national standard for tapered pipe threads, or ISO-7-1 threads are available. Tee-Let threaded and grooved welding outlet fittings are UL/ULC Listed and FM Approved for use in the fire sprinkler systems installed in accordance with the requirements of NFPA Bulletin 13. They are rated for 300 PSI operation in fire sprinkler systems, and higher pressures in other non-critical piping systems. Tee-Lets are offered in a wide variety of header sizes. The consolidated header sizes shown in the following charts allow the fittings to be Installed on more than one header size, permitting the first size listed to fit the header perfectly, while a small gap along the longitudinal center line of the header will appear for the second size listed. Merit® Weld-Miser Tee-Lets® are identified by a lot number that provides full traceability per ISO 9000 specifications. For Your Piping Systems Specify Weld-MiserTM Tee-Let Branch Outlet Fittings shall be Merit Weld-Miser Tee-Let, Lightweight forged steel, employing low weld volume profile to provide for full penetration welds with minimum burn through and pipe distortion on Schedule 5 thru 10, proprietary thin wall, and standard wall pipe. Threads are to be ANSI B1.20.1, or ISO-7-1, and the bore of the fittings calculated to improve flow. Welding outlets to be UL Listed, FM Approved for use conforming to NFPA, Bulletin 13 and pressure rated for 300 PSI maximum. How to Order - Use either of the following methods for ordering Merit® Weld.MiserTM Tee-Let® Method No. 1 Method No. 2 Specify quantity desired followed by the part Use the following system: number shown in the "dimensions" chart for the type and size of outlet desired. - Type Merit Steel Quantity Part Number Quantity $ Outlet Size * Header Size $ Weight End Tee-Let Material $ Always Column "A" Insert size Sch. 10 A - Female Thread order a few of Chart consolidation Standard B - Male Thread more than from Column C - Cut Groove actually "B" of chart. C/R - Roll Groove required for the lob .JIVILStar' Merit -1.10 —3— R,e fto&cts DM,ondMwI b,tmatjcn& Weld-Miser TM Tee-Let® Welding Outlet Fittings > VIED drIes coi4ct pieswitatto For Fire Protection & Other Low Pressure Piping Systems Merit Weld-Miser Tee-Lets Welding Branch Outlet Fillings offer the user a high strength, low cost forged threaded and grooved line of fittings specifically designed and manufactured to be Installed on Schedules 5 thru 10, proprietary thin wall flow pipe and standard wall pipe. Merit Tee-Lets are forged steel welding outlet fillings. The material used in manufacture meets the chemical and physical requirements of ASTM A 53, Grades A or B, Type E, A-135, A-795, Tee-Lets employ a low weld volume design to provide for either a partial or full penetration weld employing a single pass with minimum burn-through and pipe distortion. Weld Miser Tee-Lets are recommended for use on proprietary thin wall, Schedules 5, 10 and 40 pipe. Threads comply with ANSI B1.20.1 or lSO7/1. They are UL Listed and FM Approved for use conforming to the requirements of Bulletin 13 1999 of the National Fire Protection Association. When used in fire sprinkler systems, Tee-Lets are rated for 300 psi. When used in mechanical systems, maximum pressures are calculated using criteria developed for ASME B31 piping code. Illl7Ltilhu11l Outlet Model Outlet Pipe Size (Inch) IAPPROVA L GUIDE CHAPT Header Pipe Size (Inch) I PIPE i.iFITTINGS) i Rated Pressure (psig) Tee-Let Type A (F-Threaded End) ½/41 11/4, 1½. 2, 2½. 3,4 14.8(Sch.10,40) 300 6 (EZ-Flow) ½- 4 (Sch. 5, DynaFlow) 2 4 (EZ-Flow) - 2,4 Tee-Let Type C (Grooved End) 11/4.8 11/4-8(Sch.10,40) 300 214-8 l.4 (Sch. 5, DynaFiow) Tee-Let Type C/R (Roil Grooved End) 11/4 -6 11/4-8 (All Schedules) 300 Size-on-size (i.e. 2 x 2) Tee-Lets are not FM Approved, FM rated working pressure when welded on Sch. 5 or non-threadable lightwall pipe is 175 psi. —4 - Mont -1.10 aiJ4Ih.IBtar e Pducti D4vtdoi, ofMOIMernatIonaI Type A Female Three 4 AIT Weld-Miser 1M Tee-Let® Welding Outlet Fittings TTfl jJfl!j iaii;i lE1I1?T Part Nominal Nominal Outlet inside Make Weight Number Outlet Header Length Diameter Up Each A B C 0 M NPT(8SP1) In (m a,) In (mm) In (mm) In (mm) In 'min) Lb. (g 1002002 ¼x ¼-B 0.080 0 8200 004 1005012 11/4 - 1½ 1.063 0.700 0.500 0.171 37 •W 270 17.8 121 0.08 1005015 114-2 1.063 0.700 0.500 0.171 ½x .10- 10 21.11 178 12.7 0.08 1005020 2 -214 1.063 0.700 0.500 0.171 ____ .50 65 '10 178 121 0.08 1005025 2½-B 1.063 0.700 0.500 0.169 65 700 210 178 12.1 1 008 1007012 11/4 -114 1.125 0.900 0.500 0.260 32 40 286 229 121 012 1007015 1½-2 1.125 0.900 0.500 0.260 - 3/4 x IL) 50 28.6 22 9 72.7 0.12 1007020 2-214 1.125 0.900 0.500 0.260 5J , 65 28.6 22.9 12.1 1 0.12 1007025 214-8 1.125 0.900 0,500 0.256 65 200 286 229 12 1 0.12 1010012 11/4-114 1.250 1.145 0.500 0.331 11(01112 .12- 40 31.8 29.1 12,' 0.15 1010015 1½-2 1.250 1.145 0.500 0.331 1/63015 4t) 50 31.8 29.! 12.1 0.15 1010020 2-2½ 1.250 1.145 0.500 0.320 111002,) lx :10 65 318 29.1 12.7 0.15 1010025 214-3 1.250 1.145 0.500 0.314 111002.5 65 80 31.8 29.1 12.7 0.14 1010030 3-4 1.250 1.145 0.500 0.309 1110030 80- 100 31.8 29.1 12.1 0.14 1010050 5-8 1.250 1.145 0.500 0.291 1110050 /25-200 3)8 291 12.1 013 1012012 1/4 1.375 1.490 0.500 0.432 11 121)12 32 34.9 37.8 127 .019 1012015 1½-2 1.375 1.490 0.500 0.421 1112015 40-50 349 578 12.1 .019 1012020 2 - 21/t 1.375 1.490 0.500 0.421 1112026 1¼x ' 5065 34.9 37.8 127 .019 1012025 214-3 1.375 1.490 0.500 0.411 1112025 65 80 34.9 37.8 12.7 .019 1012030 3-4 1.375 1.490 0.500 0.389 1112030 80 /00 34.9 318 /21 318 1012050 5-8 1.375 1.490 0.500 0.389 11/2050 L'S 200 349 31.3 12.1 .018 1015015 1½ 1.625 1.610 0.875 0.477 1115375 40 413 .21.9 22.2 .322 1015020 2 1.625 1.610 0.875 0.477 111.020 1½x 59 41.3 .2.9 22.2 022 1015025 214 1.625 1.610 0.875 0.477 1113025 ' 52 413 -52.9 2_4.752 1015030 3•4 1.625 1.610 0.875 0.477 1 80 /Ui '/1.3 .JJO L'2s .22 1015040 4 1.625 1.610 0.875 0.477 .11/51)43 206, 47.3 ell 2 .7 1015050 5-8 1.625 1 1.610 0.875 0.477 WELD-MISER" DIMENSIONS & PART NUMBERS Part Nominal Nominal Outlet Inside Make Weight Number Outlet Header Length Diameter Up Each as A B C D M ?JPTt3SPfl In (mm) In (mm) In (mm) In (mm) In (mm) Lb. (4) 1020020 2 1.750 2.067 0.875 0,857 1120020 5t) 445 . 52.5 22.2 038 1020025 21h 1.750 2.067 0.875 0.829 1720023 65 44.5 52.5 222 0 3 1020030 3 1.750 2.067 0.875 0.829 1120030 2x So 445 525 222 039 1020040 4 1.750 2.067 0.875 0.800 1120040 - - 1 .14 tt 52.5 222 0.1/1 1020050 5 1.750 2.067 0.875 0.743 1120050 125 44.5 52.5 222 034 1020060 6 1.750 2.067 0.875 0.743 1120060 150 4.5 52.5 22.2 031 1020080 8 1.750 2.067 0.875 0.743 /120090 200 .145 52.5 222 u.J4 1025025 21h 2.215 2.469 1.125 1.250 '125025 55 543 62.7 28.6 05 1025030 3 2.215 2.469 1.125 1.200 1125030 Oil 530 62.1 28.6 053 1025040 4 2.215 2.469 1.125 1.150 1125040 2½x ' -' W11) 310 621 28.6 052 1025050 5 2.215 2.469 1.125 1.150 1125050 126 54.0 627 28,6 052 1025060 6 2.215 2.469 1.125 1.150 1125060 150 540 62.7 28.6 0.52 1025080 8 2.215 2.469 1.125 1.150 1125080 200 540 62.7 28.6 0.52 1030030 3 2.500 3.068 1.500 1.550 - 80 63.5 11.9 381 1030040 4 2.500 3.068 1.500 1.450 3x 100 63.5 11.9 38/ 066 1030050 5 2.500 3.068 1.500 1.450 125 63.5 779 1 38.1 0.66 1030060 6 2.500 3.068 1.500 1.450 151; 62.5 /7.9 35.1 0.66 1030080 8 2.500 3.068 1.500 1.450 230 63.5 179 38.) 0.68 1040040 4 3.000 4.026 2.000 2.850 506 1.29 1040050 5 3.000 4.026 2.000 2.850 - 4x 17. 102 102.3 .5158 1.29 1040060 6 3.000 4.026 2.000 2.800 p6.2 164,J j8 12' 1040080 8 3.000 4.026 2.000 2.800 '62 t 50 1 1.2 Note: Part #1002002 Is not UL Listed or FM Approved. Part #1012012 is not FM Approved. All size-on-size (i.e 2 X 2) Tee-Lets are not FM Approved Awvkmtar- Merit - 110 -6- Rm PmductsDMiian dAwA bTt?cnazJani - Ii Weld-Miser 1M Tee-Let® Welding Outlet Fittings Type B Male Thread Standard Weight Type C Cut Groove Standard Weight Bf flI!dI V DIMENSIONS tnnu SIZES 1"i:iu.a Male Thread Cut Groove Nominal Outlet Nominal Header Outlet Length Inside Diameter Outside Diameter Wall Thickness W NPT(3SPT) NPT(BSPT) In. (mm) In.(mrn) In.(rn,v) In.(snrn) In4ini17) 1310012 2010012 1¼-1½ 3 1.049 1.315 0.133 32 40 80 26 :11.4 34 1310015 2010015 1½-2 3 1.049 1.315 0.133 lx /0 50 80 26o 3/ 3.4 1310020 2010020 2-2½ 3 1.049 1.315 0.133 - . ) 6j 80 26 b- 334 3.4 1310025 2010025 2½-4 3 1.049 1.315 0.133 65- 10/) 80 6 33 4 54 1310050 2010050 5-8 3 1.049 1.315 0.133 175 20/) 80 266 33.4 3.4 1312012 2012012 11/4 3 1.368 1.660 0.140 3, 24 / 422 3.6 1312015 2012015 114 3 1.368 1.660 0.140 1¼x 40 So 34.? 422 36 1312020 2012020 2-2½ 3 1.368 1.660 0.140 __________________ • '0/. 55 80 .5/ / 42.2 3 6 1312025 2012025 3-4 3 1.368 1.660 0.140 80 /00 10 341 422 36 1312050 2012050 5-8 3 1.368 1.660 0.140 /35 .5 80 3-1 7 422 3.6 1315015 2015015 1½ 3 1,610 1.900 0.145 40 86 1139 48.3 3.? 1315020 2015020 2 3 1.610 1.900 0.145 1½x 50 80 409 48.3 3.7 1315025 2015025 214 3 1.610 1.900 0.145 65 80 40.9 48.3 31 1315030 2015030 3-4 3 1.610 1.900 0.145 80 100 80 40.9 48.3 3.7 1315050 2015050 5-8 3 1.610 1.900 0.145 /25 -201) 80 /0.9 48.3 3.1 1320020 2020020 2 3 2.067 2.375 0.154 80 525 80.3 39 1320025 2020025 214 3 2.067 2.375 0.154 65 80 525 60.3 39 1320030 2020030 3 3 2.067 2.375 0.154 2x 80 80 52 60.3 3.9 1320035 2020035 4 3 2.067 2.375 0.154 _______________ • /00 90 52.5 60.3 3.9 1320050 2020050 5 3 2.067 2.375 0.154 /25 80 52.s 60.3 39 1320060 2020060 6 3 2.067 2.375 0.154 /50 80 52.5 60.3 59 1320080 2020080 8 3 2.067 2.375 0.154 233 20 1 52.5 I VUJ Note: Tee-Lets are manufactured to fit size-on-size. that is the rnntnared shane on a nivan Taa-I at k mada to fit narfatk, on tho firt Iictoi1 haadar 67A If inct2tlo,1 on the second header size marked on the titting,a slight gap of approximately I, will appear along the longitudinal centerline of the header. For example, al'x2 - 2½' Tee-Let, is a 1' outlet fitting manufactured to fit perfectly on the 2' header size listed, while leaving a 1/32' gap along the longitudinal centerline of the 214' size. If a perfect fit Is required for a 214' header pipe, then a 1"x 214 -3' Tee-Let would be ordered. Size consolidations are employed to reduce Inventory and provide for greater flexibility. -6- Merit- 1.10 Ale Produce oodufon of MM IntwadomaI &MEFR I To Type B Male Thread Standard Weight Type C Cut Groove Standard Weight TypeC/R Weld.MiserTM Tee-Let® Roll Groove Schedule 10 Welding Outlet Fittings WELD-MISER "I -LET*~' - DIMENSIONSI Ii Cut Roll Groove Nominal Nominal M e T ead Outlet Inside Diameter 0 Outside Wall Thickness - F Standard Schedule Standard Schedule Sid. Groove Std. Outlet Header Length Diameter WI. A B C Weight 10 F Weight 10 NPT(flSO 7- 1) Nfl (ISO-i 1) NPT(1S0-7- 1) !n.(mnl) In.(rnm) Ill. ('71m) In.(mm) In.(inm) !n.(mm) In.(mm) In-(m,) 1325025 2025025 2225025 214 3 2.469 2.635 2.875 0.203 0.120 2125025 90 62.! 67.0 15.2 5.0 3.0 1325030 2025030 2225030 3 3 2.469 2.635 2.875 0.203 0.120 2125030 80 80 627 670 76.2 5.0 3.0 1325035 2025035 2225035 4 3 2.469 2.635 2.875 0.203 0.120 2125035 2½ x 130 80 62 1 570 762 50 1325050 2025050 2225050 5 3 2.469 2.635 2.875 0.203 0.120 2125050 123 50 527 67.0 76.2 50 3,0 1325060 2025060 2225060 6 3 2.469 2.635 2.875 0.203 0.120 2125060 150 80 02.1 57.0 . 76.2 . 50 3.11 1325080 2025080 2225080 8 3 2.469 2.635 2.875 0.203 0.120 2125080 20 80 621 67.5 /6.2 .911 30 1330030 2030030 2230030 3 3 3.068 3.260 3.500 0.216 0.120 80 80 780 83.0 58.0 50 3.0 1330035 2030035 2230035 314 3 3.068 3.260 3.500 0.216 0.120 85 80 75.iJ 83.11 88.0 5.0 3.0 1330040 2030040 2230040 4 3 3.068 3.260 3.500 0.216 0.120 3 X 8' lOU 88 (8.0 83.0 88.0 s.D 30 1330050 2030050 2230050 5 3 3.068 3.260 3.500 0.216 0.120 123 811 /8,0 33.0 88.6 Si) .3.0 1330060 2030060 2230060 6 3 3.068 3.260 3.500 0.216 0.120 80 18.0 83.0 880 5.0 3.0 1330080 2030080 2230080 8 3 3.068 3.260 3.500 0.216 0.120 200 1 80 73.0 83.0 88.0 1 5.0 30 1340040 2040040 2240040 4 4 4.026 4,260 4.500 0.237 0.120 100 /00 102.0 108.0 114.0 8.0 3.0 1340050 2040050 2240050 5 4 4.026 4.260 4.500 0.237 0.120 0 .. 123 100 102.0 108.0 114.0 6.0 3.0 1340060 2040060 2240060 6 4 4.026 4.260 4.500 0.237 0.120 1511 L lOU /02.0 108.0 1/4.0 1 5.0 3.0 1340080 2040080 2240080 8 4 4.026 4.260 4.500 0.237 0.120 200 !Oi) 102.0 168.0 114.0 6.0 30 - 2050050 - 5 4 5.047 - - 5 X 125 1011 126.2 - 2050060 - 6 4 5.047 - - '00 1252 - 2050080 - 8 4 5.047 - - 00i 1282 - 2060060 2260060 6 4 6.065 6.357 6.625 0.280 0.134 6x sj 155 '.5 .10 - 2060080 2260080 8 4 6.065 6.357 6.625 0.280 0.134 22j '5 116d :1 30 - 2080080 - 8x 8 4 i , Ji. ~ 7.981 8.329 1 8.625 0.322 0.148 JO Note: Tee-Lets are manufactured to fit size-on-size, that is the contoured shane on a nhien Ten-Let is made to fit nerfettiv on the first listed hP21ar size If int2IId on the second header size marked on the fitting, a slight gap of approximately 1," will appear along the longitudinal centerline of the header. For example, a 1' x 2 - 2½' Tee-Let, is a 1' outlet fitting manufactured to fit perfectly on the 2 header size listed, while leaving a ½2 gap along the longitudinal centerline of the 214' size. If a perfect fit is required for a 214' header pipe, then a 1' x 21/t - 3 Tee-Let would be ordered. Size consolidations are employed to reduce Inventory and provide for greater flexibility. .ifiJtI.Star Ment -1/0 -7- Ae Pioduets i,tion dAml Ufl,maIonai July 2012 For the most current product/pricin information on Anvil products, plea. our website at www.anvilintl.co () ANVIL Building Connections That Last Steel Pipe Nipples & Malleable Fittings BUILDING CONNECTIONS THAT LAST Ouv.xi CaIawsa wtsCWML (* bwu.-siTUTJ SMNOLE Anvil International is the only manufacturer where you can combine your import and U.S. Manufactured product requirements. J1 2;l II Dimensional: I ASTM A733 Standard End Finish Tapered Pipe Thread (NPT) Material: I ASTM A53 Type F or Type E Galvanizing: I Hot Dip Galvanizing* Threading:** I ASME B 1.20.1 *Galvanized nipples are manufactured from pipe coated on the inside and outside by hot dip process. **British Standard threading per BS 21 available upon request. Ends are cut square to the central axis. All burrs on the inside are removed. The ends of the pipe nipples are chamfered on the outside at an angle of 350 +1- 100 to the central axis. Pipe nipples are threaded on both ends with standard NPT tapered threads. Threads are right hand on both ends. Also available: Ready Cut Pipe, Standard - Schd. 40 (black and galvanized) Pipe Size: /2", 3/4' 1", 174, 11/2", 2" Pipe Length: 8', 24", 30", 48", 60", 72" "66" Packs, Standard - Schd. 40 (black and galvanized) Nipple Size: /2, '/4",1", 174, 11/2",2" Single Run Nipple Packs (black and galvanized) Pipe Size: 1/2, 3/4', 1, 1/4, 1/2, 2" Pipe Pipe Length Size 0. D. Close 1 /8 .405 3/4 1'/2 2 2 /2 3 3 /2 Nipple Lengths 4 4'/2' 5 (Black 5'/' 6 galvanized) j7 8 ' 9 10 fl '12 1/4 .540 7/8 1 1/2 2 2 /2 3 3 1/ 4 4 /2 5 5 1/2 6 7 8 9 10 11 12 3/8 .675 1 l'/2 2 2 '/2 3 372 4 4 '/2 5 5 1/2 6 7 8 9 10 11 12 1/2 .840 1 1/8 1 1/2 2 2 '/2 3 3 '/2 4 4 '/2 5 5 '/2 6 7 8 9 10 11 12 3/4 1.050 1 /8 1 '/2 2 21/2 3 3 1/2 4 4 '/2 5 51/. 6 7 8 9 10 11 12 1 1.315 1'/2 2 272 3 31/2 4 4'/2 5 5'/2 6 7 8 9 10 11 12 1 1/4 1.660 1 /8 2 21/3 3 31/2 4 4 /2 5 5 '/2 6 7 8 9 10 11 12 1 /2 1.900 1/4 2 2'/2 3 3'/2 4 4 /2 5 51/2 6 7 8 9 10 11 12 2 2.375 2 2'/2 3 3'/2 4 4 '/2 5 5 '/2 6 7 8 9 10 11 12 2 '/2 2.875 2 '/2 3 3 '/2 4 4 1/2 5 5 1/2 6 7 8 9 10 11 12 3 3.500 2/g 3 3 '/2 4 4'/2 5 5'/2 6 7 8 9 10 11 12 4 4.500 2 '/8 4 4'/2 5 5'/2 6 7 8 9 10 11 12 6 6.625 1 3'/8 4 1 4h 5 5 /2 6 7 1 8 9 10 11 12 Class 150 (Standard) Size A Weight / No woomax __• .jcr. Size A Weight 0.63 'JO6 sWt. I www.anvilintl.com Class 150 (Standard) CAP Size A Weight (u1\ 1 A 1/8 A 0.53 0.03 '/4A 0.63 0.05 /8 A 0,74 0.07 ½ 0.87 0.11 3/4 0.97 0.18 1 1.16 0.30 P/4 1.28 0.44 1 1/2 1.33 0.55 2 1.45 0.85 2 1/2 1.70 1.49 3 1.80 2.20 3 1/2 1.90 3.02 4 2.08 3.79 6 2.55 8.77 A Supplied in Steel only (Black and (a1van1zed). TEE Size A Weight A A 1/8 0.69 0.09 1/4 0.81 0.14 0.95 0.21 ½ 1.12 0.31 '/4 1.31 0.50 1 1.50 0.79 1 1/4 175 119 1 ½ 1.94 1.57 2 2.25 2.43 2 1/2 2.70 4.33 11.03 6 5.13 25.98 Li www.anvilintl.com 1 [Ii TI1II11LI!rTI] REDUCING COUPLINGSMMM" ifr4. tl. -i 1 I A I J I '/4xY8 1.00 0.07 %x½ 1.13 0.09 .13 0.10 ½x½ 1.25 0.13 '/2x¼ 1.25 0.13 '/2 X 1.25 0.14 %x½ .44 0.18 3/4 x'/4 1.44 0.20 1.44 0.21 3/4 x 1/2 1.44 0.22 1X'/2 .69 0.34 1 x 3/4 1.69 0.36 1 ¼x½ 2.06 0.47 1 1/4 X~ 2.06 0.51 1 '/4x1 2.06 0.57 1 1/2 X 1/2 2.31 0.62 1 /2x/4 2,31 0.66 1'/2x1 2.31 0.73 1 Y2x1 1/4 2.31 0.80 2x½ 2.81 0.94 2x 3/4 2.81 0.99 2 x 1 2.81 1.03 2x1'/4 2.81 .17 2x 1 ½ 2.81 1.25 2'/2x1 1/4 3.25 .81 2'/2x1 ½ 3.25 1.90 2 1/2 X 2 3.25 2.04 3 x 1 3.69 2.48 3 x 1 1/4 3.69 2.55 3 x 1 ½ 3.69 2.67 3 x 2 3.69 2.78 3 x 2 ½ 3.69 3.23 4 x 2 4.38 4.43 4x2½ 4.38 4.87 4 x 3 4.38 5.29 PLUGS + Solid ¼ 0.44 0.28 0.38 0.04 Solid 3/ 0.48 0.31 0.44 0.06 Cored ½ 0.56 0.38 0.56 0.08 Cored 3/4 0.63 0.44 0.63 0.13 Cored 1 0.75 0.50 0,81 0.20 Cored 1 '/4 1 0.80 0.56 0.94 0.32 Cored 1 '/2 0.83 0.62 1.13 0,43 Cored 2 0.88 0.68 1.31 0.67 Cored 2½ 1.07 0.74 1.50 1.11 Cored 3 1.13 0.80 1.69 1.53 Bar Plug 4 1 1.22 1.00 - 2.71 Bar Plug 6 1 1.40 1.25 - 4.00 Eli www.ahvilintI.com 1 Lightweight Flexible Coupling qg:S:P~F~/RNVIL The C-3 Coupling is a flexible light weight style which is ideal for fire protection services and other services where low pressure and ambient temperature conditions are expected. For the latest UL/ULC listed, [PC B, VdS and FM Approved pressure ratings versus pipe schedule, see www.anvilintl.com or contact your local Anvil Representative. c®us <3> opm LISTED APPROVED For Listings/Approval Derails and Limitations, visit our website at weenanvilintl.com or contact an Anvit° Sates Representative. MATERIAL S:J i I [.fi I Es] ' HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval-neck track head bolts conforming to ASTM A- 183 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A-563 Grade A or Grade B, or SAE J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. METRIC BOLTS & HEAVY HEX NUTS: Heat treated, zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts and bolts are zinc electroplated followed by a yellow chromate dip. COATINGS: 0 Rust inhibiting paint Color: ORANGE (standard) E] Hot Dipped Zinc Galvanized (optional) 0 Other available options: Example: RAL3000 or RAL9000 Series For other coating requirements contact an Anvil Representative. LUBRICATION: 0 Standard Gruvlok 0 Gruvlok XtremelM required for dry pipe systems and freezer applications. GASKETS: Materials Properties as designated in accordance with ASTM D-2000. El Pre-Lubricated Grade "E" EPDM, Type A Gasket (Violet color code) -40°F to 150°F (Service Temperature Range)(-40°C to 65°C) Recommended for wet and dry loll free air) pipe fire protection sprinkler systems. For dry pipe systems and freezer applications, Gruvlok XtremeTM Lubricant is required. E Grade "E" EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. El Grade "EP" EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. GASKET TYPE: 0 Standard C Style 0 Flush Gap PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: []Approved as noted Contractor: 0 Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: FP-4,12 EM .cILIGHTWEIGHT FI1I :] IE COUPLING Nominal ' Pipe ' Max. End Range of Deflection From Q. Coupling Dimensions Coupling Bolts Specified Torque § Approx. Size 0. D.PressureA Working load separation Wt. Ea. Per Coupling Pipe X Y Z Qty. Size Mm. Max. In./DN(mm) In./mm PSI/bar Lbs./kN In./mm Degrees In./Ft. -mm/in In/mm In./mm In./mm In/mm FL-Lbc/N.m Lbs/Kg 1.315 300 407 0-½2 10 22' 0.29 2/2 4 1/4 2 x 21/4 30 45 1.2 25 1 334 20.7 1 1.8/ 00.79 1 23.8 64 /02 44 MI0x57 1 40 60 1 0.5 11/4 1.660 300 649 0.1/32 10 5, 0.23 23/4 41/4 11/4 2 3/ x 21/4 30 45 1.3 32 42.2 20.7 2.89 00.79 /8.8 70 I/I 44 M lox 50 40 60 0.6 1½ 1.900 300 851 0.1/32 00 57' 0.20 3 41/2 13/4 2 3/a x21/4 30 45 1.5 4u 46.3 20.7 3.78 00.15 165 76 1/7 44 - ,10 x 50 40 60 0.7 2 2.375 300 1,329 0-½2 00 45' 0.16 3% 5 1% 2 % x 21/4 30 45 1.7 50 1 603 207 59/ 00.79 1 /3/ 66 140 40 - Al!01 57 40 60 0.8 21/2 2.875 300 1,948 0-1/32 00 37 0.13 3% 51/2 11/8 2 3/ x 21/4 30 45 2.0 65 73.0 20.7 Bus 00.79 /0.9 99 /48 48 Ml0x57 40 60 0.9 30.0. 2.996 300 2,1/5 0-',. 036' 0/3 4'. 53. / 2 i.',7. 30 45 1.9 76.1 76.1 20.7 9.41 0-0.79 10.4 105 146 48 - M10 x 57 40 60 0.9 3 3.500 300 2,886 0-½2 0° 31 0.11 41/2 6/a 1% 2 1/2 x 2½ 30 45 2.6 80 839 20.7 12.8 0079 89 /14 /58 48 - Ml0x63 10 60 1.2 4 4.500 300 4,771 0-/31 10 12' 0.67 61/a 8 21/4 2 '/a x 31/2 80 100 4.1 lOU //1.3 20.7 2/22 ((-2.38 55.5 156 203 57 - /2/2.170 /10 /50 1.9 5a/0.0. 5.500 300 7,727 0-' . 059' 0.54 61,a 916 2 2 3 /x3½ /00 /30 5.5 139.7 139.7 20.7 31.70 0-2.38 45.4 175 237 57 - M16 x 89 135 175 2.5 5 5.563 300 7,292 0-/32 00 58' 0.54 7 9/it 2¼ 2 Vax3¼ 100 130 5.7 125 /4/3 207 32.11 064 45 178 237 37 Ai1635 135 /75 26 60.0 8503 300 9,955 0 (('50' ((Ia 7 /(('.; 7 2 'x3' /00 130 6.1 165.1 165.1 20.7 1 44.28 0-2.38 1 34.8 200 1 267 57 1 - M16 x 85 135 175 1 2.8 6 6.625 300 10,341 0-/32 00 49 0.45 81/4 101/4 21/4 1 2 Vax 31/4 100 130 6.1 /50 /68.3 201 4600 0-238 37.8 2/0 273 5/ - M/6x85 135 /75 2.8 8 8.625 300 17,528 0-3M 0° 37' 0.35 10% 131/3 2½ 2 1/4 x 41/4 130 180 11.9 200 2/9.! 20/ 7797 02.38 291 210 343 64 /3120x 1/0 175 245 . 5.4 Range of Pipe End Separation and Angular Deflection values are for roll grooved pipe and may be doubled for cut groove pipe. Working pressure and/or end load are total allowable, based on standard weight steel pipe, roll or cut grooved. One time held test pressure may be increased to 1.5 times the figures listed above. § - For additional Bolt Torque information see Technical Data Section. A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, FM, VdS and LPCB pressure ratings versus pipe schedule, please visit anvilint(.com or contact your local Anvil Representative. FP-4.12 I WARNING For dry pipe systems and freezer applications lubrication of the gasket is required, Gruviok® XtremeTM Lubricant is required. The C-4 Rigid Coupling is our standard coupling and is designed for rigid piping applications. The C-4 is specially designed to provide a rigid, locked-in pipe connection to meet the specific demands of rigid design steel pipe. For the latest UL/ULC listed, LPCB, VdS and FM Approved pressure ratings versus pipe schedule, see www.anvilintl.com or contact your local Anvil Representative. c®us LTED APPROVED (n) For Listings/Approval Details and Limitations, visit our website at wswnanvilinticom or contact an AnviP Sales Representative. MATERIAL SPECIFICATIONS 7 HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval-neck track head bolts conforming to ASTM A-i 83 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A-563 Grade A or Grade B, or SAE J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. METRIC BOLTS & HEAVY HEX NUTS: Heat treated, zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts and bolts are zinc electroplated followed by a yellow chromate dip. COATINGS: Rust inhibiting paint Color: ORANGE (standard) [I Hot Dipped Zinc Galvanized (optional) []Other available options: Example: RAL3000 or RAL9000 Series For other coating requirements contact an Anvil Representative. LUBRICATION: 0 Standard Gruvlok []Gruvlok XtremeTM required for dry pipe systems and freezer applications. GASKETS: Materials Properties as designated in accordance with ASTM D-2000. 0 Pre-Lubricated Grade "E" EPDM, Type A Gasket (Violet color code) -40°F to 150°F (Service Temperature Range)(-40°C to 65°C) Recommended for wet and dry (oil free air) pipe fire protection sprinkler systems. For dry pipe systems and freezer applications, Gruvlok XtremeTM Lubricant is required. 0 Grade "E" EPDM (Green color code) -40° F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. O Grade "EP" EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. GASKET TYPE: El Standard C Style E] Flush Gap PROJECT INFORMATION APPROVAL STAMP Project: [:]Approved Address: []Approved as noted Contractor: []Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: FP-4.12 Rigid Coupling CSPF/RNV~I:Q~ 161 m. II!ii - ti_Il 11111 C-4 IRIGIDICOUPLING Nominal I Pipe ' Max. ' Max. Coupling Dimensions Range of Pipe Coupling Bolts Specified Torque § Approx. Size 0. D. Working PressureA End Load End Separation x Y z Wt. Ea. - Qty. Size Mm. Max. In./DN(mm) In/mm PSI/bar Lbs./kN In/mm In./mm In Am In 1mm In ./Mm Ft.-Lbs./N-m Lbs/Kg 1 1.315 300 407 0-½ 2/t 4 ]3/4 2 3/tx2'/4 30 45 1.2 23 33.4 20.7 1.81 0-0.79 60 /02 44 IV, l0x37 40 60 0.3 1/4 1.660 300 649 0.1/32 2/4 41/8 ]7/ 2 3/t x 21/4 30 45 1.5 32 42.2 20.7 2.89 0-0.79 70 /17 48 #110x 57 40 60 0.7 11/2 1.900 300 851 0/ 213/it 47/s ]7/ 2 /8 x 2V4 30 45 1.7 40 43 20.7 3.78 0-0.79 7/ /24 1 48 4110x 57 40 60 0.8 2 2.375 300 1,329 0.1/32 31/2 5% 2 2 /t x 21/4 30 45 1.9 50 60.3 207 59/ 1 0-079 89 /37 5/ M10x37 40 60 0.9 21/2 2.875 300 1,948 0-½2 4 6 2 2 %x2½ 30 45 1.9 63 73.0 20.7 8.66 0-0.78 202 /52 51 - MIOx 63 10 60 0.9 30.1/. 2996 300 2,115 0-'. 4'.. 6,, I'' 2 '- 2" 30 45 22 76.1 76.1 20.7 9.41 0-0.79 105 156 1 48 - M10 x 63 40 60 1.0 3 3.500 300 2,886 0.1/32 43/4 61/8 2 2 3/ x 21/2 30 45 2.4 80 1 88.9 20.7 /2.84 0070 /2/ /68 51 M/0x63 40 60 1.1 4 4.500 300 4,771 0-/32 51/8 73/4 2'/t 2 3/ x 21/2 30 45 3.2 /00 1/4.3 20.7 21.22 0-2.38 149 /97 54 - lJ10 63 40 60 1.1 5-00 5500 300 7/2/ 0, 6 2 .3 88 100 5 139.7 139.7 20.7 31.70 02.38 175 235 52 M12 x 76 110 150 2.2 5 5.563 300 7,292 0-%2 6%o 9Yi 2'A6 2 ½ x 3 80 100 4.5 25 141.3 20.7 32.44 0-2.38 /76 230 1 52 - M12 76 NO /50 2.0 600 6.500 300 953 0-' 8. /0 2. 2 '9 80 100 5.8 165.1 165.1 20.7 44.28 0-2.38 207 264 54 1412 x 76 110 150 2.6 6 6.625 300 10,341 0-/32 8114 10% 21/6 2 ½x3¼ 80 100 5.8 /50 1683 20.7 4600 0-2.38 2/0 264 54 t//282 1/5 /50 26 8 8.625 300 17,528 0-/32 10/2 131/4 21/2 2 1/8 x 31/2 100 130 10.8 200 Z19l 20.7 /7.97 0-2.38 267 337 64 M10x89 /30 /75 4.5 10 10.750 300 27,229 0.3/33 13 161/4 21/8 2 ¼x5 180 220 21.5 250 273! 20.7 /21/2 0-2.38 33/ 425 67 - //22x/23 245 298 98 12 12.750 300 38,303 0-/32 15/8 191/4 2% 2 ¼ x 51/2 180 220 27.4 300 323.9 20.7 1 /70.38 0-2.38 39/ 485 67 - M22x /40 243 298 /2,4 Range of Pipe End Seperation values are for roll grooved pipe and may be doubled for cut groove pipe. Working pressure and/or end load are total allowable, based on standard weight steel pipe, roll or cut grooved. I A WARNING One time held test pressure may be increased to 1.5 times the figures listed above. For dry pipe systems and freezer applications § - For additional Bolt Torque information see Technical Data Section. lubrication of the gasket is required, ------D..,:......L.....C...-----------JL...._1___L ..-,.. .,,1.i_,,,,,, ,,,,.-.,,,- Gruvioke XtremeTM Lubricant is required. - -.--'- ''''T' ----------------rr' ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Other sizes available, contact an Anvil Representative. FP-4.12 c®us <> OLPM LISTED APPROVED For Listings/Approval Details and Limitations, visit our wabsite at =nv.anvll!nt1.com or contact an Anvil Sales Representative. CAST FITTINGS: Ductile Iron conforming to ASTM A-536 FINISH: O Rust inhibiting paint Color: ORANGE (standard) or El Hot Dipped Zinc Galvanized conforming to ASTM A-i 53 (optional) U Other available options: Example: RAL3000 or RAL9000 Series I II'1TiY 0CSP7F/RNV1>L O.D. to Nominal Max. o D Max. Center Approx. Size to End ure In/ Press Wt. Ea. In./DN(mm) mm PSI/bar In/mm lbs/Kg 1 1.315 300 21/4 0.6 25 33.4 20.7 57 03 1¼ 1.660 300 2/i 0.8 32 42.2 20.7 70 0.4 11/2 1.900 300 21/4 1.1 40 1 48.3 20.7 70 0.5 2 2.375 300 31/4 1.5 50 60.3 20.7 83 0.7 2/2 2.875 300 33/4 2.5 65 73.0 20/ 95 1.1 300. 2,996 300 3, 29 76.1 1 76.1 20.7 95 1.3 3 3.500 300 41/4 4.2 80 88.9 20.7 108 1.9 4 4.500 300 5 6.7 /00 114.3 20.7 /27 3.0 51h O.D. 5.500 300 51h - 139.7 139.7 20.7 140 - 5 5.563 300 51/2 11.9 l2 /4/3 201 /40 5.4 6.00 6.500 300 18.2 165.1 165.1 20.7 165 8.3 6 6.625 300 61/2 17.3 /50 1 168.3 2011 /45 8 8.625 300 71/4 32.2 200 219.1 20.7 197 146 10 10.750 300 9 54.1 250 2/5.1 2u./ 229 24,5 12 12.750 300 10 70.0 300 1 3239 1 207 1 254 318 PROJECT INFORMATION APPROVAL STAMP Project: 0 Approved Address: LjApproved as noted Contractor: 0 Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: FP-4.1 2 c®us CLPM) LISTED APPROVED For Listings/Approval Details and Limitations, Visit our website at www.anvilintl.com at contact an Anvil' Sales Representative. 0CSP7F/RNV1>L The Model RC-2 Reducing Coupling makes it possible to directly connect two different pipe sizes, eliminating the need for two couplings and a reducing fitting. The specially designed reducing coupling gasket with a center rib assures proper positioning of the gasket and prevents the smaller pipe from telescoping into the larger during assembly. Working pressure ratings shown are for reference only and are based on schedule 40 pipe. For the latest UL/ULC listed, LPCB, VdS and FM Approved pressure ratings versus pipe schedule, see www.anvilintl.com or contact your local Anvil Representative. Model RC-2 Coupling complete with Grade "E" EPDM Gasket. Reducing Coupling Housing LGasket Gasket Center Rib MATERIAL SPECIFICATIONS HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval-neck track head bolts conforming to the physical properties of SAE J429 Grade 5 with a minimum tensile strength of 120,000 psi and heavy hex nuts of carbon steel conforming to ASTM A-563 Grade A, or J995 Grade 2 Bolts and nuts are provided zinc electroplated as standard. METRIC BOLTS & HEAVY HEX NUTS: Heat treated, zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts and bolts are zinc electroplated followed by a yellow chromate dip. COATINGS: Rust inhibiting paint Color: ORANGE (standard) [I Hot Dipped Zinc Galvanized (optional) 0 Other available options: Example: RAL3000 or RAL9000 Series For other coating requirements contact an Anvil Representative. LUBRICATION: OStandard Gruvlok Gruviok XtremeTM required for freezer applications. GASKETS: Materials Properties as designated in accordance with ASTM D-2000. E Grade "E" EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. PROJECT INFORMATION Project: APPROVAL STAMP LjApproved Address: EjApproved as noted Contractor: J Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: FP-4.12 Reducing Coupling INVIL RC-2 REDUCIPJGI.s1IJ :.] II [c Nominal I Larger I Smaller I Max.Max. End I Range of I Deflection From I Coupling Dimensions I Coupling Bolts Specified Torque § I Approx. Size 0.D. 0.0. Working Pressure, Load Pipe End Separation Wt. Ea. Per Coupling Pipe X V Z Qty. Size Mm. Max. In./DN(mrn) In./rnm In/mm PSI/bar Lbs./kN In/mm Degrees In/Ft -mm/rn In/mm In/mm In./mm In/mm Ft-Lbs/N-rn Lbs/Kg 2 x 1½ 2.375 1.900 300 1,329 0-V32 00 45' 0.16 31/8 51/s ]7/ 2 /2 x 2/4 80 110 2.0 50x40 60.3 48.3 20.7 5.19 0-0.79 13.1 92 149 .18 41/8.76 /10 150 0.9 21/2 x 2 2.875 2.375 300 1,948 0-/32 00 37' 0.13 41/4 6% 1¼ 2 1/2 x 21/4 80 110 3.5 65x50 73.0 60.3 20.7 8.67 0-0.79 10.9 /08 /62 48 - M1276 1/0 150 /6 300.x2 2.996 2.375 300 ZIIS 0-] 036 0/2 4] 6] 1] 2 2", 80 /10 3.3 76 x 60 76.1 60.3 20.7 9.41 1 0-3.2 9.9 108 1 162 48 1 - M12 x 16 110 150 1.5 3 x 2 3.500 2.375 300 2,886 0-½2 00 31 0.11 41/8 1 71/s 1% 2 1/2 x 21/4 80 110 4.4 80x50 88.9 60.3 1 20.7 1 2. 84 0-079 89 /24 /8/ 40 0]22 78 I/O /50 2.0 3 x 21/2 3.500 2.875 300 2,886 0-½2 00 31' 0.11 41/8 71/8 11/8 2 1/2 x 2% 80 110 4.1 80.195 88.9 70 20] 12.84 0-0.79 8.9 /24 181 48 - MIll/U 1/0 150 1.9 3s30.D 3.500 2996 300 2,886 0-1 03/ 0.11 4' 7. I 2 'x2-. 80 /10 4.0 88 X 16 88.9 16.1 20.1 12.84 0-3.2 8.9 124 181 48 - M12 x 76 110 150 1.8 4 x 2 4.500 2.375 300 4,711 0-/32 10 12' 0.25 61/4 81/8 2 2 1/8 x 3½ 100 130 8.9 1001 50 1/4.3 603 1 20.7 21.22 0-2.36 20.8 /59 1 223 51 - 4l It, . 95 135 175 1 4.0 4 x 21/ 4.500 2.875 300 4,771 0-3/32 10 12' 0.25 61/4 37/s 2 2 1/8 x 3½ 100 130 7.9 /00165 /143 130 207 2/22 0-2.38 20.8 159 225 5/ - 416x95 /35 /75 3.6 4 x 3 4.500 3.500 300 4,771 0-/32 10 12' 0.25 61/4 8718 2 2 1/8 x 31/2 100 130 6.7 100x80 1 1/4.3 88,11 20.7 21.22 0-2.38 ______ 20.8 /59 225 51 - 4//oY5 /35 175 30 4u300 4.500 2 996 300 4,77/ 0.. i'll' 025 6 8] 2 2 ]-x3 /00 130 7.6 114 X 76 114.3 76.1 20.1 21.22 0-4.8 20.8 159 225 51 - M16 x 95 135 115 1 3.5 5 0.0 4 5.500 4500 300 1,128 0_i /58 0.20 7] 10' 2- 2 ".i 4/ /00 /30 /1.4 139X114 139.7 114.3 20.7 31.71 0-4.8 10.8 184 270 54 1 M20x115 1 135 115 5.2 5 x 3 5.563 3.500 300 7,292 0-¼ 10 58' 0.20 7114 105/8 21/8 2 1/4 x 41/2 130 180 10.4 128.60 141.3 80-9 207 32.44 0-6.4 /6.8 /84 270 54 - M20 /15 /75 245 4.7 5 x 4 5.563 4.500 300 7,292 0-/32 10 581, 0.20 71/4 10/t 21/8 2 3/4 x 41/2 130 180 11.4 /25 Y /00 141.3 1/4.3 20.7 1 42.44 0-2.38 /6.8 /84 1 270 54 M20x /15 /75 1 245 5.2 .0.8..3 6.500 3500 300 9955 0-' /20' 0.26 8.' II. 2/ 2 ,4 /30 180 /50 165 X 88 165.1 1 88.9 20.7 44.28 0-6.4 18.2 210 295 54 - M20 x 115 175 245 6.8 6 0014 6500 4500 300 9955 0 / 20' 0.26 8. 1/' 2/ 2 .4.. 1311 /80 /3.6 165 Xl 14 165 114.3 20.7 44.28 0-6.4 18.2 210 295 54 - M20 x 115 175 245 6.2 6 x 4 6.625 4.500 300 10,341 0•/32 00 49 0.11 81/4 ]J5/ 21/8 2 3/4 x 41/2 130 180 13.4 30 X 100 168.3 /143 207 1 4600 0-238 141 210 1 295 34 '128. 1 /75 1 245 61 6 x 5 6.625 5.562 300 10,341 0-/32 00 49 0.17 81/2 111/8 21/8 2 114 x 41/2 130 180 13.5 /50,t /25 /683 1413 207 46.00 0-2.38 /4 / 2/6 295 54 /420,1115 /75 245 6.1 8 x 6 8.625 6.625 300 17,528 0-/32 0-37- 0.13 10V2 14 21/4 2 1/4 x 4/7 130 180 17.7 203x/50 2/91 483 20.7 77.Y7 0238 /0.9 267 365 57 - 4/lOx/IS /75 245 80 8.6 0.9 8.625 8509 300 17,528 0-' 031' 0.13 10. /1 2/ 2 ' x4'. /30 180 /8. 219 X 165 219.1 165.1 1 20.1 77.91 0-6.4 10.9 1 267 1 365 57 - M20 115 1 175 1 245 8.3 Not for use in copper uystems. Range of Pipe End Separation and Angular Deflection values are for roll grooved pipe and may be doubled for cut groove pipe. See technical data section for coupling data chart notes. § - For additional Bolt Torque information see Technical Data Section. A - Working Pressure Ratings are For reference only and based on Sch. 40 pipe. For the latest UL/ULC, FM, VdS and LPCB pressure ratings versus pipe schedule, please visit anv/l/nt/.com or contact your local Anvil Representative. Other sizes available, contact on Anvil Representative, FP-9.12 c®uS <3> OLPM LISTED APPROVED For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil' Sates Representattan. MATERIAL SPECIFICATIONS CAST FITTINGS: Ductile Iron conforming to ASTM-A536 COATINGS: 11 Rust inhibiting paint Color: ORANGE (standard) or OHot Dipped Zinc Galvanized conforming to ASTM A-i 53 (optional) 0 Other available options: Example: RAL3000 or RAL9000 Series I FIG. SK-1 E to E SK -1 GROOVED CAP Nominal 0 D End Approx. Size to End WI. Ea. InJDN(mm) In 1mm In./mrn LbslKg 1.315 1¼ 0.3 25 33.4 25 0.! 11/4 1.660 1 0.4 32 42.2 25 0.2 1¼ 1.900 1 0.5 40 48.3 25 0.2 2 2.375 1 0.7 50 1 60.3 25 0.3 21/2 2.875 1 1.0 65 730 25 0.4 30.0 3.000 1 09 76.1 76.1 25 0.4 3 3.500 1 1.5 80 889 25 0./ 4 4.500 1 '116 2.7 IOU 111.3 2/ 1.2 5 5.563 1½o 4.4 125 1413 27 2.0 60.0 6500 I 5.5 165.1 1 165.1 25 2.5 6 6.625 1/to 6.6 150 1683 2/ 36 8 8.625 1 3A6 11.3 200 219 30 51 10* 10.750 1¼ 21.0 250 213 / 32 5.5 12* 12.750 1% 35.5 300 3239 1 32 1 16/ 'Supplied as Slyle K-i only. PROJECT JIIlINFORMATI ON J Project: El Approved Address: IjApproved as noted Contractor: i:i Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: FP-4.12 ® Listed Max. Horizontal Load System Sch. 45"NPS -59" 30"-44" 60"-89" 90" 1-11/2" 10-40 1383 765 2"- 4" 7-40 1383 1956 2394 2765 9.1 - fill fl i 2394 2765 1383 1956 2394 2765 10' 10-40 1383 1956 2394 2765 12" 10.40 1870 2645 3238 1 3740 43' Certified Max. ASD Horizontal Loads System NPS Sch. 30"-44' 45"-59" 60"-74" 75o-90o 1.1 1/2" 10,40 1680 2380 2920 3250 2'- 3" 10,40 1800 2350 3120 3490 4" 10,40 1930 2370 2640 5,6,8" 10,40 730 1040 1270 1420 * SPECIALLY LISTED PIPE A ST Pipes PVT LTD Al Jszenra Steel Products Co. SAOG Allied Tube & Conduit Corp. Biltar Tubes LTD, Bluesteet Services L L C Borusan Mannesmann Born AS Boll Moose Tube Co. Conoens Metal Supply LTD. Hai Chin Worldwide LTD Hickman Pipe & Tube Corp. J,edong Economy Development Testing Zone Jindol Industries LTD Jotindra Steel & Tubes LTD Mittal Canada Inc. MS Pipe Co. LTD Northwest Pipe Co. Pacific Pipe Public Co. LTD Sobs Thai Steel Pipe Public Co. LTD Shield Flee Safety & Security LTD Ssmryu Roohiti LTD Swastik Pipes LTD Ten-Tube Co. Universal Tube & Plastic Industries LTD Wetfang Eros Pipe Industry Technical Co. LTD Welded Tube . Berkeley LLC Wheatland Tube Co. WI, Div. Yieh Phul Enterprise Co. LTD Young ,town Tube Co. Zenith Birla (India) LTD P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 035 SWAY BRACE FITTING MODEL K 1 mm. 4I 5 thru 12 inch pipe SIZE -SYSTEM PIPE: Nominal Steel 1" thru 12" * Steel Specially listed - see chart. CPVC 1" thru 3". Brace common O.D. - Copper, Plastic, FRP, Ductile and Cast Iron SIZE - BRACE PIPE: 1" thru 2" Sch. 40 Mm. 11/4" required for 12" system pipe MATERIAL - Carbon steel and ductile iron. FINISH - Plain or E.G. PATENTS - No. 7,516,922 No. 7,523,895 LISTING/APPROVAL - 203A EX 2625 LISTED FM Approved - 1950 OSHPD See Website. FUNCTION - Lateral fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION - Per these instructions including NFPA 13 or FM 2-8 and CPVC manufacturers instructions. Load rating - see chart. ASSEMBLY - See drawing. Combine with proper AFCON components- see disclaimer below. Insert brace pipe through bores to achieve minimum I" extension. Tighten 035 set screws until heads bottom out. FEATURES * Patented - designed for system pipe of varying material. * Improved assembly - extra large bore for brace pipe. * Visual inspection, verifies proper installation. * Superior load ratings. ORDERING - Part #, size - system pipe, size - brace pipe and finish. * COMMONLY KNOWN AS SCH. 7 Special Note: Thin wall sprinkler pipe has a propensity for damage to its circumference resulting in egging. When condition exists - shift mounting location. Specific AFCON products are exclusively designed lobe compatible ONLY with other AFCON products including ports and fasteners, resulting in o listed sway brace, restrainer or hunger assentbly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, ports or systems not manufactured or sold by AFCON. AFCON shall NOT he liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used, 3/13 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 077 ATTACHMENT FITTING LOCKING 17/32 17 SIZE - BRACE PIPE: 1" and 1 1/4" Sch. 40 MATERIAL - Carbon Steel, Ductile Iron or S.S. (Type 304). FINISH - Plain or E.G. LISTING/APPROVAL - c®us LBTD 203A-EX2625 FM Approved - 1950 OSHPD See Website. FUNCTION - Structure attachment fitting of anAFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION - Per these instructions including NFPA 13 FM 2-8. Load rating - see chart. ASSEMBLY Combine with proper AFCON components- see disclaimer below. Insert brace pipe thru fitting near pivot bolt. Tighten set bolt until head contacts bracket. FEATURES * Swivel allows attachment at any angle. * Visual inspection, verifies proper installation. * Larger fastener hole available.- Consult factory. ORDERING - Part #, size - brace pipe and finish. Max. Horizontal Load Size 1-2 ® Ductile Base 2015 1500 Steel Base 2015 Specific ,4FCON products are exclusively designed to be compatible ONLY with other ,4FCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by ,4FCON. .4FCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss olbusiness or profit, when non-A FCON products have been, or are used. 3/13 Part # 077-........ 78 P.O.. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 411 SWAY BRACE FITTING SIZE - SYSTEM PIPE: Nominal Pipe Size 1" - 12" Steel - Sch. 40 1 1/4" - 12" Steel - Sch. 10 MATERIAL - Carbon Steel FINISH - Plain or E.G. PATENT - No. 7,140,579 LISTING/APPROVAL C®US 203A-EX 2625 40* FM Approved -1950 APPROvED OSHPD See Website. ® Listed Max. Horizontal Load System NPS Sch. 30"-44" 45"-59" 60"-89" 90" 1"- 11/2 1383 2394 2765 2'- 4" 7-40 1383 1956 2394 2765 5"- 6" 7-40 83 6 94 fl 8" j4 83 6 94 2765 10" 10-40 1383 1956 2394 2765 12" 10-40 1870 2645 3238 3740 FUNCTION - Longitudinal fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION - Per these instructions including NFPA 13 or FM 2-8 Load rating - see chart. A QI71,Iflf V - 'ci3 Certified Max. ASD Horizontal Load System NPS Sch. 30"-44" 45"-59" 60"-74" 75"-90" 1-1 1/2" 10-40 420 510 570 2-3" 7-40 860 1030 1150 7-40 860 1030 1150 7-40 950 1150 1280 7-40 2220 2220 3040 8" 1340 1620 1810 - Combine with proper AFCON components- see disclaimer below. Align brace member parallel to face of 411 bolt flanges. Tighten 411 bolts until flanges are flat to flat. FEATURES * Patented - design eliminates bending of ears during installation. * Patented - design prevents over tightening on system pipe. * Improved assembly - ears connected for superior strength. * Visual inspection - proper installation when 411 bolt flanges are together. ORDERING - Part #, size - system pipe and finish. Specific AFCONproducts are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 5/13 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org SWAY BRACE ADAPTER SIZE -SYSTEM PIPE: See Chart. MATERIAL - Carbon Steel. FINISH - Plain or E.G. PATENT - No. 6,334,285 LISTING/APPROVAL - c®us 203A-EX 2625, 203-EX 2551 LiSTED .e. FM Approved -1950 OSHPD OPA-0601 See Website FUNCTION - Sway brace adapter for an AFCON sway brace assembly. Designed to attach to the horizontal flanges of a steel structural memb Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. Additionally listed as an 8" hanger attachment. INSTALLATION - Per NFPA 13 and these instructions. Load rating - see chart. Combine with proper AFCON components- see disclaimer below. The structural members design will dictate specific attachment criteria ASSEMBLY - See drawing. Insert 1/2" x 1 1/4" attachment bolt in 086 bracket. Install 1/2" studs it. brackets and engage on steel flange. Install nuts on studs finger tight additionally tighten 11/2 turns or torque to 40ft. lbs. Attach AFCON sway brace assembly on 1/2" bolt. * Studs, fasteners and bolt furnished by customer FEATURES * Fits 1/4" thru 1 1/4" flange thickness. * Studs capture head of bolt, providing hold back. * Alternative to center loading beam clamp. ORDERING - Part # and finish. Specific .4FC0.'\' products are exclusively designed to be compatible ONLY with other AFCON products including parts attd fasteners. resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER -A FCON will NOT warrantagainst the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCO,V shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind. including but not limited to loss of business or profit, when non-AFCON products have been, or are used. . 11/11 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 100 REVERSIBLE BEAM CLAMP 3/4" MOUTH SIZE - ROD: 3/8" SIZE - SYSTEM PIPE: 4" max. SIZE - ROD: 1/2" SIZE - SYSTEM PIPE: 8" max. MATERIAL - Ductile iron. FINISH - Plain, E.G. and H.D.G. LISTING/APPROVAL - c®u8203-EX 2551 FM Approved FUNCTION - Attachment component of an AFCON hanger. To support horizontal piping. INSTALLATION - Per NFPA 13 and these instructions. Install on steel flange - thickness less than 3/4". Set bolt up or down. ASSEMBLY/ATTACHMENT - See drawing. Torque - 3/8= 60 inch lbs. or 1/2= 125 inch lbs. In the absence of a torque wrench, engage set bolt finger tight then additionally tighten 1/4 turn. Caution - Do not over tighten set bolt. FEATURES * Maintains CONSTANT HANGER CENTER-LINE, with set bolt up or down. * Flat throat back to prevent twisting on structure during installation. ORDERING - Part #, rod size and finish. 11/09 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 162 UNIVERSAL RESTRAINING STRAP Nut optional, if insufficient rod dimension SIZE- One size fits both 3/8' and 1/2" rod or set screw. Available lengths 4" and longer. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTINGS - ck7,Jl us 203-EX 2551 PATENT - No. 5,897,088 FUNCTION - To enhance hanger attachment in areas subject to Earthquakes. INSTALLATION - Install tight to structure and component parts Minimum return on strap: 1" L-dimension is measured from hanger rod center to the strap end. FEATURES * Fast installation for new construction or retrofit. * Requires no hanger disassembly to install. IMPORTANT NOTE: "No Nut Is Required" When installed tight to structure and component parts. (See drawings provided) ORDERING - Part # and L-dimension. 1/08 LENGTH P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org ME EYE ROD NOT WELDED 1/08 A ROD SIZE A B MAX. REC. LOAD LBS. FOR SERVICE TEMP. 650 °F 3/8 7/16 21/2 210 1/2 9/16 21/2 395 5/8 13/16 21/2 630 3/4 1 3 945 7/8 11/8 31/2 1315 1 11/4 4 1735 11/4 11/2 1 5 2800 11/2 2 6 4070 1 3/4 21/4 7 5490 2 21/2 8 7240 21/4 23/4 9 9520 21/2 3 10 11725 NOTE: 'A" dimension should not be 1/16" larger than fastener. Please notify factory if larger "A" dimension is needed. SIZE - 3/8 thru 7/8 inch rod. MATERIAL - Carbon Steel. FINISH - Plain, E.G., H.D.G. and S.S. FUNCTION - For attaching to and hanging from wood beams where bolting through beam is desired. ORDERING - Part #, rod size, length, width of bend and finish. *POSSIBLE ALTERNATE = PART #535 SEE CUT SHEET I 4 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER I thru 4 inch pipe LISTED FOR STEEL/CPVC 1I2&3/4 inch pipe 5 thru 8 inch pipe SIZE - ROD- 3/8" or 1/2" SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel, Mu. Galvanized to G-90 spec. LISTING/APPROVAL - c®US LISTED 203-EX 2551 1"- 8" Approval guide - 1"- 8" OSHPD OPA-060 1 See Website. CONFORMS WITH: Federal Specification WW-H-171E, Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe. INSTALLATION - Per NFPA 13, 13R, 131), these instructions and the CPVC or èopper pipe manufacturers instructions. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. NFPA 13 PIPE ROD I WI. 5 WT.+250 UL TEST LOAD 1 3/8 30.75 403.75 750 11/4 3/8 43.95 469,75 750 11/2 3/8 54.15 520.75 750 2 3/6 76.95 1 634.75 750 21/2 3/8 118.35 841.75 850 3 1 3/8 162.30 1061.50 1050 4 3/8 246.00 1480,00 1500 5 1/2 349,45 1996.75 2000 6 1/2 476.35 2631.75 1 2650 8 1/2 711.00 3805.00 4050 PIPE A A ___ 1,8793 2,5259 \I 1 114 2.1382 2.7850 U A B 2.6048 3.2516 2 112 3.4920 4,1150 '\H 3 3.7845 4.4311 1 + , 44358249992 6 6.0688 6.8180 8 7,5768 8,3290 11/09 SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. 551 It Restraint P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTINGS - c us 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. S "0 Specilic AFCONproducts are exclusively designed lobe compatible ONLY with other AFCONproducts including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER -A FCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by .4FCON. .4FCON shall NOT be liable under any circumstances whatsoever for any director indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non.AFCON products have been, or are used. 1/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 650 ALL THREADED ROD 10'- O' LENGTHS ROD SIZE MAX. REC. LOAD LBS. FOR SERVICE TEMP. 650°F 750°F 1/4 240 215 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 1 4960 4420 1 1/4 8000 7140 11/2 11630 10370 NOTE; maximum Temperature: 750°F SIZE - 1/4 thru 1 1/2 inch rod in 10'- 0 lengths. MATERIAL - Carbon Steel. FINISH - Plain and E.G., ORDERING - Part #, rod diameter and finish. 12/10 SIZE - ROD: 3/8" SIZE - SYSTEM PIPE: 4" max. MATERIAL - Carbon Steel. FINISH - Plain, E.G. and S.S. LISTING/APPROVAL - C® LOTED us 203-EX 2551 T 00 000 2.0312 t øe' I 13/8 L..1.250 Special Note: The purlin lip is not capable of supporting NFPA 13 fire sprinkler pipe at 1(wt.) +250 lbs mm. When purlin manufacturers specify 200 lbs. max. ® Locations It, BorE 3@ A - C - C 0 0 2(4 B-E 3(4 B-D-F 0 2(4 A-C 4(4 A-C-O-F P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 551 REVOLVER Tm TAPPED BRACKET PATENT - No. 6,568,642 FUNCTION - Attachment component of an AFCON hanger. To support horizontal piping. INSTALLATION - Per NFPA 13 and these instructions. Install on vertical mounting surface. ASSEMBLY/ATTACHMENT - See drawing. Center mounting hole accepts 3/8" and 1/2" fasteners. *FASTENER LOCATION OPTIONS - See chart. Vertical - Hangs plumb from first fastener. Stops wood splitting along the grain. Horizontal - When vertical space is limited. FASTENERS PER NFPA 13 LISTED FOR STEEL PIPE - SEE TABLE. FEATURES * Universal fastener array for enhanced mounting. * Radius -Tapped orifice: Aligns rod for easy thread engagement and eliminates structural deficiencies associated with rod inserts. * No speed/pal nuts required. ORDERING - Part # and finish. C®US MOUNTING FASTENERS LISTED Wood Steel — 1/4 or #14 Tek Steel — #10 SMS or #905 Fastener Qty. Steel Mm. Qty. Steel Mm. Qty. Steel No Pre-Drill Pipe Thickness Pipe Thickness Pipe 1/4x 1/2 LB 1 2 14 GA. 1 3 18 GA. 1 2 '/2 24 24 2 3 #14 x 1 V2 SMS 1 2 16 GA. 1 2 V2 3 4 2 4 2 4 20 GA. 2 3 #16x2DS 2 2 18 GA. I 2¼ 4 4 3 4 2 3 22 GA. 3 3 Wood Thru 5/8" Gyp. 3 4 20 GA. *1 2 1/4 x 2 LB 1 2 2 4 @BONLY 2 3 SMS SIrcrIMctaIScrew 3 4 OS Drive Screw #14x2SMS 1 2 LB Lag Bolt 24 22 GA. 3 2 '/2 Gyp= GypsurnBoard 5111 r_,' I kWoo No pre-drilling required. 'Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. Watch a video demonstration at . www.itwbuildex.com 1/4" 8002957 GST 100 1/4 xl" 210 (7/16" OSB) 25 125 670 (3/4" Ply) jQi 1/4' 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 3/8" 8007957 GST 10 1/4 xl" 210 (7/16" OSB) 300 25 125 670 (3/4" Ply) 3/8" 8008957 GST 20 1/4x2 1760 (Fir) 850 1475 25 125 3/8" 8068925 GST 20-SS 1/402" 1760 (Fir) 850 25 125 #14 Black 3/8" 8009925 GST 2380 3/8 x 2-1/2" 2113 (Fir) 1500 25 125 Nut Driver '." 3/8" 8010957 GST 30 1/403" 2060 (Fir) 1500 1475 25 125 Part # 8113910 3/8 8069925 GST 30-SS 1/4x3 2060 (Fir) 25 125 I 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25 125 1/2" 8015925 GST3 1/4x3" 2275 (Fir) 25 125 #14 SW Red Nut Driver Part # 8114910 Aft MAUFCURED u.s.c. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. -'.--- -' .5.-, .--' ' r' ''• 8007957 GST 10 318 Vertical CPVC 1-112" 300 1-1/2" 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2' 300 1-1/2" 8008957 GST 20 3/8" Vertical 2-1/2" 850 1-1/2" 4" 1475 1-1/2" 8068925 GST 20-SS 3/8' Vertical 2-1/2" 850 1-1/2" 8010957 GST 30 3/8" Vertical 4" 1500 1-1/2" 4" 1475 1-1/2" 8009925 GST 25-380 3/8" Vertical 4" 1500 1-1/2" 8022925 SWG 25-380 3/8" Horizontal 3-1/2' - 4* 1500 1-1/2" 8021957 SWG 20 3/8" Horizontal 2-1/2" -3"" 1050 1-1/2" 8073925 SWG 20-SS 3/8" Horizontal 2-112" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45" Angle off Vertical 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45" Angle off Vertical 4" 1500 1-1/2" 8139957 SH-GST2O 3/8" 17" Angle off Vertical 1050 1-1/2" 4" 1475 1-1/2" SkM_M_YSf0R STEEL - PIPE HANGER - iiin SteelfQk Max 11 Steel Th16k. 8038957 DSTR 1 3/8" Vertical 1500 .035" 4" 1475 .105" 8037957 DSTR 1-1/2 3/8" Vertical 4" 1500 .035" 4" 1475 .105" 8039957 DSTR 516 3/8" Vertical 4" 1500 .037" 4" 1475 .105" 8045957 DST 516 3/8" Vertical 4" 1500 .188" 4" 1475 .188" 8046957 TEKSO 3/8' Vertical 4" 1500 .250" 4" 1475 .188" 8055957 SWDR 1 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8056957 SWDR 516 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8054957 SWDR 1-1/2 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8137957 SH-DSTR 1 3/8' 17' Angle oft Vertical 4" 1500 .035" 4" 1475 .105" 8268957 SH-TEK 50 3/8" Vertical 2-1/2" 850 70' Angle oft Vertical 4" 1500 8150922 XP 20 3/8" Vertical 2-1/2" 850 .027" 2" 940 .029" 4" 1475 .105" 2" 940 8153922 XP 35 3/8" Vertical 4" 1500 .029" .060' 4" 1475 .125" 8294922 SXP 20 3/8" Vertical or up to 45" 2" 750 .027" 2" 635 .029" 8295922 SXP 35 3/8" Vertical orupto89" 3-1/2" 1250 .060" 2" 635 .029" 8293957 SWXP 35 3/8' Horizontal 3-1/2" 1250 .060" 8059957 CST 20 3/8" Vertical 4" 1475 3000 8061957 SWC 20 3/8" Horizontal 4' 1475 3000 8150922 XP 20 3/8" Vertical 2-1/2" 850 Pre-Pour Structural @ 3000psi 8150922 Part XP 20 Model 3/8" Vertical Rod 2-1/2" Mount 850 Post-Pour Range II LWC 535 PCF (lbs/It) UL Load UL Min Steel Number Size Direction Rating (lbs) Thickness 185 .027" 8150922 XP 20 3/8" Vertical 250 .035" 8153922 XP 35 3/8" Vertical 185 .027' 250 .035" 8181922 XP 200 1/4' Vertical 185 .027" 250 .035' 8294922 SXP 20 318" Vertical 170 .027' 45' 80 .027" 8295922 SXP 35 3/8" Vertical 250 .060" 90" 80 .060" 8293957 Part SWXP 35 Rod 3/8" Mount UL Load Horizontal UL Min. Steel 80 .060" Number SAMMYS FOR Model STEEL - CONIJUIT Size TUBING, Direction Rating (Ibs) AND CABLE Thickness Listed Application 8150922 XP 20 3/8" Vertical 283 .027' Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 3/8' Vertical 283 .027" Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8293957 SWXP 35 3/8" Horizontal 500 .060" Max 4 trade size EMI & 6 trade sue RMC. IMC, and rigid PVC conduit 8149957 CZ2000 1/4" or 3/8" Onto Vertical Rod UL Listed 4S16 - Cable Hanger, Cat. No. C-Z2000 Plenum Rated, Sheet Steel Complies w/ NEC Standards Gauge No. Gauges 22 ga. 20 ga. 18 ga. 16 ga. 14 ga. 12 ga. 1/8" 3116" 114" Nominal Decimal Equivalent .030" .036" .048" .060" .075" .105" .125" .188" .250" SWG 25-3e0 Maximum pipe size in composite wood joist allowed by UL is 3-1/2 UL compliance with NEC Standards. SWG 25-3e0 Maximum pipe size in wood limber or joist allowed by UL is UL and FM tests were performed in compliance with NFPA 13 Standards. 'SWG 20 Maximum pipe size in composite wood mist allowed by UL is 2-1/2" Fastening requirement: 5 times weight of water-filled schedule 40 pipe plus 250 pounds. 'SWG 20 Maximum pipe size in wood timber or isist allowed by UL is 3" _V, Traditional methods for installing branch line restraints in fire sprinkler systems are cumbersome and time-consuming. Contractors often cut (and re-cut) threaded rod to precise measurements to restrain the sprinkler pipe with a loop hanger and surge restraint. Traditional methods also commonly require five or more parts per restraint. To avoid these labor-intensive methods, [RICO has streamlined the process and developed the Branch Line Restraint System, part of the CADDY® line of hanging and bracing solutions for the fire protection market. Ideal for restraining 1" (25 mm) through 2" (50 mm) branch lines, this innovative system is significantly faster and easier to install than current methods. It attaches directly to steel bar joists, I-beams or purlins, as well as concrete and wood structures. The hardware is installed with only one tool, a 5/16" (8 mm) socket drill driver, which provides significant labor savings and convenience. It features a simple, two-step installation process, allowing a time savings of up to 80% compared to other methods. Unlike most solutions that only accept 3/8" (MI 0) threaded rod, the versatile Branch Line Restraint System features a swivel attachment that can be rotated to accept 3/8" or 1/2" (M10 or M12) threaded rod. This allows greater restraint distances from the pipe to structure with 1/2" (M12) threaded rod. The system meets the requirements of NFPA® 13, making it ideal for new construction applications. The total system is cULus® Listed and FM® Approved, and has been pre-approved by the state of California (OSHPD OPA-2629-1 0). Features Complete restraint system is quick and easy to install Offers up to 80% time savings per branch line restraint Eliminates need to cut threaded rod to exact dimensions Works with 3/8" and 1/2" (M10 and M12) rod Capable of restraint distances up to 40" (960 mm) from pipe to structure with 1/2" (M12) threaded rod Meets requirements of NFPA® 13 section 9.3.6 Branch Line Restraint Pipe Attachment www.erico.com 1 ERICD Branch Line Restraint Structure Attachment to Steel Branch Line Restraint Structure Attachment to Wood/Concrete Branch Line Restraint Structure Attachment to Threaded Hole www.erico.com ERICD //"'Nk V7/ Features Accepts 3/8" or 1/2" (M10 or M12) threaded rod Quick grip clamp simplifies measuring and cutting of threaded rod Works with rough-cut threaded rod and eliminates pipe-side deburring Can be installed with threaded rod above or below the service pipe Shear-off head helps ensure correct torque and simplifies inspection Specifications Material: Steel Finish: Electro-galvanized ? C®US www.erico.com 3 ERICD Features Swivel connector accepts 3/8" or 1/2" (M10 or M12) threaded rod Attaches to steel members with self-drilling/tapping screw 0 FT -I CADDY' CSBBRS RS LJ Specifications Material: Steel Finish: Electro-galvanized c®us Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. www.erico.com 4 ERICO Features Swivel connector accepts 3/8" or 1/2" (M1O or M12) threaded rod Attaches to wood or concrete structures J Specifications Material: Steel Finish: Electra-galvanized c®us Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. www.erico.cam 5 ERICLY Features Swivel connector accepts 3/8" or 1/2" (M 10 or M12) threaded rod Attaches to concrete anchors or structural attachments with female threads Specifications Material: Steel Finish: Electro-galvanized ,~ C®Us Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. cULus is a registered certification mark of UL L-C. FM is a registered certification mark of FM Approvals L-C, LTD. NFPA is registered trademark of National Fire Protection Association, Inc WARNING ERICO products shall be installed and used only as indicated in ERICO's product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your ERICO customer service representative. Improper installation, misuse, misapplication or other failure to completely follow ERICO's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death. WARRANTY ERICO products are warranted to be free from defects in material and workmanship at the time of shipment. NO OTHER WARRANTY, WHETHER EXPRESS OR IMPLIED (INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), SHALL EXIST IN CONNECTION WITH THE SALE OR USE OF ANY ERICO PRODUCTS. Claims for errors, shortages, defects or nonconformities ascertainable upon inspection must be made in writing within 5 days after Buyer's receipt of products. All other claims must be made in writing to ERICO within 6 months from the date of shipment or transport. Products claimed to be nonconforming or defective must, upon ERICO's prior written approval in accordance with its standard terms and procedures governing returns, promptly be returned to ERICO for inspection. Claims not made as provided above and within the applicable time period will be barred. ERICO shall in no event be responsible if the products have not been stored or used in accordance with its specifications and recommended procedures. ERICO will, at its option, either repair or replace nonconforming or defective products for which it is responsible or return the purchase price to the Buyer. THE FOREGOING STATES BUYER'S EXCLUSIVE REMEDY FOR ANY BREACH OF ERICO WARRANTY AND FOR ANY CLAIM, WHETHER SOUNDING IN CONTRACT, TORT OR NEGLIGENCE, FOR LOSS OR INJURY CAUSED BY THE SALE OR USE OF ANY PRODUCT. LIMITATION OF LIABILITY ERICO excludes all liability except such liability that is directly attributable to the willful or gross negligence of ERICO's employees. Should ERICO be held liable its liability shall in no event exceed the total purchase price under the contract. ERICO SHALL IN NO EVENT BE RESPONSIBLE FOR ANY LOSS OF BUSINESS OR PROFITS, DOWNTIME OR DELAY, LABOR, REPAIR OR MATERIAL COSTS OR ANY SIMILAR OR DISSIMILAR CONSEQUENTIAL LOSS OR DAMAGE INCURRED BY BUYER. Copyright Bi 2012 ERICO International Corporation. All rights reserved. CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation. www.eriCo.Com 6 ERICD (E)POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (10 1mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 deep weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. UL, ULC, and FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC I2OVAC I2VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (400 to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells - 4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep weatherproof backbox Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (-34° to 66°C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. ULC only applies to MBA DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at loft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6(150) 12VDC MBA-6-12 1750070 .12A 85 76 8(200) 12VDC MBA-8-12 1750080 .12A 90 77 10 (250) 12VDC MBA-10-12 1750060 .1 2A 92 78 6(150) 24VDC MBA-6-24 1750100 .06A 87 77 8(200) 24VDC MBA-8-24 1750110 .06A 91 79 10(250) 24VDC MBA-10-24 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .17A 91 78 8(200) 24VAC PBA248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .17A 94 78 6(150) 120VAC PBA1206 1806120* .05A 92 83 8(200) 120VAC PBA1208 1808120* .05A 99 84 10(250) I20VAC PBAI20I0 1810120* 1 .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or BBX-1. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC • St. Louis, MO, Phone: 866-572-3005/Canada 888-882-1833 www.pottersignal.com PRINTED IN USA MFG. 95400776 - REV Y-I PAGE I OF 2 01/13 Weatherproof Backbox Dimensions Inches (mm) Fig. 2 Box has one threaded 1/2" conduit entrance 3 3/B' (86) 4 (/4" (lOS) DWGII 776.2 (E)POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC Bells Dimensions Inches (mm) Fig. I DWGS 776.1 Wiring (rear view) Fig. 3 A.C. BELLS WHITE (IN) WHITE (OUT) FROM CONTROL PANEL OR PRECEDING BELL BLACK (IN) LACK (OUT) CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: I. WHEN USING AC BELLS, TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL. 2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. DIVGI 716.3 Installation The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. Remove the gong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). OM, WAM r Failure to install striker down will prevent bell from operating. PRINTED IN USA MFG. #5400776 - REV Y-I PAGE 2 OF 2 01/13 VSR (E)POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Specifications subject to change without notice. Ordering Information Nominal Pipe Size Model Part Number 2" DNSO VSR-2 1144402 2 1/2 DN65 VSR-2 1/2 1144425 3" DN80 VSR-3 1144403 3 1/2" - VSR-3 1/2 1144435 4" DNIOO VSR-4 1144404 5" - VSR-5 1144405 6" DNISO VSR-6 1144406 8" DN200 VSR-8 1144408 Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 General Information The Model VSR is a vane type watertlow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8' (50 mm thru 200 mm). LPC approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering Information chart. The VSR may also be used as a sectional waterfiow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. UL, CUL and CSFM Listed, FM Approved, LPCBApproved, For CE Marked (EN12259-5) / VdS Approved model use VSR-EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) - UL Maximum Surge: 18 FPS (5.5 m/s) Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 1251250VAC 2.0 Amps at 30VDC Resistive 10 mAmps mm. at 24VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: NEMA 4/1P54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. Temperature Range: 40°F - 120°F, (4.5°C - 49°C) - UL Non-corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. Shock hazard. Disconnect power source before servicing. Serious injury or death could result. Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. CAUTION Waterfiow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterfiow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Enclosure The VSR switches and retard device are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 www.pottersignal.com PRINTED IN USA MFG. #540146 - REV L PAGE I OF 4 3/09 VSR POTTER VANE TYPE WATERFLOW 0. The Symbol of Protection ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6" (15 cm) of a fitting which changes the direction of the waterfiow or within 24" (60 cm) of a valve or drain. NOTE: Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill (see Fig. I). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Take care not to damage the non-corrosive bushing in the saddle. The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. 1). The vane must not rub the inside of the pipe or bind in any way. A CAUTION Do not trim the paddle. Failure to follow these instructions may prevent the device from operating and will void the warranty. -- DO NOT LEA yE CO VER OFF FOR Retard Adjustment Fig. 1 E.(TENDED PERIOD OF TIME The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at the minimum required to prevent false alarms TIGHTEN NUTS - ALTERNATELY MOT ON PIPE SO ARROW ON SADDLE I POINTS IN DIRECTION OFWATERFLOW CAUTION Hole must be drilled perpendicular to the pipe and vertically centered. Refer to the Compatible Pipe/Installation Requirements chart for size. Correct Incorrect ROLL PADDLE IN OPPOSITE DIRECTION DIRECTION OF J OF WATERFLOW WATERFLOW OW wa/er ac/ivales device in one direclion only) IIwr1. 1146-11 ADAPTER AOAPTER 20mm±2v,n, MAX. DN5O ONLY USE (2) 5180162 ADAPTERS AS SHOWN ABOVE OWOP 1146.11 Compatible _Pipe/ _Installation _Requirements Model Nominal Pipe Size Nominal Pipe 0. D. Pipe Wall Thickness Hole Size U-Boll Nuls Torque Schedule 10 (UL) Schedule 40 (UL) BS-1387 (LPC) ON (VDS) inch mm inch mm inch mm inch mm inch mm inch mm inch mm fl-lb n-rn VSR.2 2 DN50 2.375 60.3 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 1.25 +.125/-.062 33.0 ± 2.0 20 27 VSR-2 1/2 2.5 - 2.875 73.0 1 0.120 3.05 0.203 5.16 - . - - VSR-2 1/2 - DN65 3.000 76.1 - . - 0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 88.9 0.120 3.05 0.216 5.49 1 0.157 4.0 0.114 2,9 ±.125 ± 50.8 2.0 VSR-3 1/2 3.5 - 4.000 101.6 0.120 3.05 0.226 5.74 - . . . VSR-4 4 DNIOO 4.500 114.3 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 VSR.5 5 - 5.563 141.3 0.134 3.40 0 258 6.55 - - VSR-6 6 DNISO 6.625 168.3 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 0.148 3.76 0.322 8.18 1 0.248 6.3 0.177 4.5 N01 L: For copper or plastic pipe use Model VSR-CF. PRINTED IN USA MFG. #5401146-REV L PAGE 2 OF 4 3/09 (EP) POTTER The Symbol of Protection VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Fig. 2 To remove knockouts: Place screwdriver at inside edge of knockouts, not in the center. reates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Fig. 3 Fig. 4 Switch Terminal Connections Clamping Break out thin section of cover when Plate Terminal wiring both switches from one conduit entrance. DING. #1146-16 An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device 6-13 inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8 of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire, capture all strands under the clamping plate. Fig. 5 Typical Electrical Connections BELL Notes: POWER 0 The Model VSR h two switches, one can be used to operate a central I SUITA SOURCE station, proprietary or remote signaling unit, while the other contact BLE FOR BELL I is used to operate a local audible or visual annunciator. A condition of LPC Approval of this product is that the electrical entry must be sealed to exclude moisture. I WAIERFLUW ZONE For supervised circuits, see "Switch Terminal Connections" EOLR ON FIRE PANEL drawing and warning note (Fig. 4). MVQ. 114&12 Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve shall always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Fig. 7 Mounting Dimensions 5.56 in Fig. 8 3.50 in 2.00 in (508 mmr' (1412mm) GREEN GROUND (89.0 mm) SCREWS Ii ________ 2.34in (59.4 mm) I PIPE DIA. U-BOLT NUT _____________ + 5.25 in _____________ U-BOLT WASHER— __________________ (+ 33.4 mm) __________ PIPE SADDLE—' .I. PIPE—' PLASTIC pADDLE—' ___ ____ DWO l46- U-BOLT---' NOMINAL PIPE DIA, +1.75 in (+44.5 MM) FOR DN 50- ON 652-2.5 in 01 0w6 l6Sl5 NOMINAL PIPE DIA, +2.125 in (+54,0 MM) FOR ON 80- ON 200 3-8 in PRINTED IN USA MFG. #5401146 - REV L PAGE 3 OF 4 3/09 DO NOT REMO' (2) RETARD HOI. SCREWS (2)LOCATI-------- (2) LOCATII BOSSES IN DWG# 1146-10 VSR 00 POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterfiow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030 (see Fig. 6). There is no maintenance required, only periodic testing and inspection. Retard/Switch Assembly Replacement (See Fig. 6) The Retard/Switch Assembly is field-replaceable without draining the system or removing the waterfiow switch from the pipe Make sure the fire alarm zone or circuit connected to the waterfiow switch is bypassed or otherwise taken Out of service. Disconnect the power source for local bell (if applicable). Identify and remove all wires from the waterfiow switch. Remove the (2) mounting screws holding retard/switch assembly to the base. Do not remove the (2) retard housing screws. Remove the retard assembly by lifting it straight up over the tripstem. Install the new retard assembly. Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. Re-install the (2) original mounting screws. Reconnect all wires. Perform a flow test and place the system back in service. Fig. 6 SCREWS HOLDING RETARD/SWITCH REMOVE (2) ORIGINAL MOUNTING ASSEMBLY TO BASE BREAK OUTTHIN SECTION OF COVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. (2) ORIGINAL MOUNTING CREWS RETARD/SWITCH ASSEMBLY IlL. Removal of Waterfiow Switch To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterfiow detectors are removed or replaced. Turn off electrical power to the detector, then disconnect wiring. Loosen nuts and remove U-bolts. Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterfiow detector saddle. Lift detector clear of pipe. PRINTED IN USA MFG. #5401146 - REV L PAGE 4 OF 4 3/09 USTED APPROVED SPECIFICATIONS Range: 0-300 PSI (Inside) 0-2000 Kpa (Outside) Accuracy: ±3-2-3% ASME B40.100 Grade B Burdon Tube: Phosphor Bronze Window: Polycarbonate one-piece ring and crystal Dial: Galvalume Pointer: Aluminum, painted black Case: PGE Xenoy8 DX2735 Connection: Brass, 1/4" ANPT LM DIMENSIONS 1.16 IN (29.5) MAX 03.46 - (MM) I- - (87.9) 0 3.88 0 3:70 (986) (940) '56 So So Q ------- 39±03 NPT .44t.04 PRESSURE A E Model 7500/Model 7600 100 Quaker Lane, Malvern, PA 19355 • Phone: 610-240-4900 • Fax: 610-240-4906 • www.testandrain.com The AGF Manufacturing, Inc. Model 7500 Pressure Gauge is an FM Approved/UL Listed 4" gauge designed for use on "wet" sprinkler systems. The AGF Model 7500 has been designed to meet the requirements specified in NFPA 13, 2007 Edition Chapters 7.1.1.1 - 7.1.1.2, 7.2.1 -7.3.1.3,7.8.7,8.16.1.2.2, and 8.17.3 The AGF Manufacturing, Inc. Model 7600 1/411 3-Way Globe Valve is a UL Listed valve designed to connect the pressure gauge to the sprinkler systems. The AGF Model 7600 has been designed to meet NFPA 13 System Attachments stating, "...each gauge shall be equipped with a shutoff valve and provision for drainage." MODEL 7500 PRESSURE GAUGE WITH MODEL 7600 GLOBE: VALVE AND l,4U STEEL PLUG PatentIIflT.lii MADE IM U.S.A. AGF Manufacturing Inc. Job Nam 100 Quaker Lane, Malvern, PA 19355 Phone: 610-240-4900 Architect: Fax: 610-240-4906 Engineer: www.testandrain.com Contractor: TESTeaDRAIN is a registered trademark of AGF Manufacturing Inc. SS-7500 2/14 TESTANDRAIN® M8000 RESIDENTIAL RISERPACK M8011 THE MODEL 7500 PRESSURE GAUGE AND MODEL 7600 3-WAY GLOBE VALVE ARE ALSO USED ON THE FOLLOWING AGF PRoDucTs: d Ml 0111 TESTANDRAIN® M8000 COMMERCIAL RISERPACKr M8011 COMMERCIAL RISERPACKtm rgsrasDAAlN is a registered trademark of AGE Manufacturing Inc. t Model 1011 A TESTANDRAIN® Sectional Floor Control Test and Drain Valve for Systems Requiring Pressure Relief Valve Sizes: The AGF Model 101 1A TESTANDRAIN provides the test and express drain functions for wet fire sprinkler systems on rnult!-story installations requiring pressure relief (NFPA 13 and NFPA 13R). The Model 1011 features a Model 7000 Pres- sure Relief Valve with drain pipe. The Model 101IA is avatiable in a full range of sizes ( to 2) with NPT connections (BSPT available). The Model 7000 Pressure Relief Valve 'LJ(UL'FM) features a flushing handle and a 175 PSI factory rating (other pressure ratings available). Complies with NFPA 13 and NFPA 13R Requirements Compact, Single-Handle Ball Valve Tamper-Resistant Test Orifice and Sight Glasses 300 PSI rated. Specifiable orifice sizes: %" (2.8K), 7/i6" (4.2K), ½ (5.6K), 17/2 (8.0K), /8" (11.2K, ELO), 3411 (14.0K, ESFR), and K25 Relieves Excess System Pressure caused by Surges or Temperature Changes Shipped with Relief Valve and Bypass Drain Ports Plugged to Expedite Pressure Testing Locking Kit Available Repair kits are available for all TESTANDRAIN® valves. Kit includes: Adapter Gasket (1), Ball (1), Valve Seats (2), Stem Packing (1), and Stem Washer (1). Valve and orifice size must be specified when ordering. NOTE: 1 is imporfant to note that the pressure rat-,g of the rehef v&ive indicetec an opnrrrOig range of oressure for both oeenng and ciosiig of the vee. EtaricNIa relief VCiVCS are squir-ed to OPEN in a range of pressure hcfviaen 00% arid 00% of tneir eating. Toe vahes are required to CLOSE at a arossac above 80% of ihOl rating Ihe rOof vC!ve drou1a be inslahed where a Seasilt a000sri0a Or n'airrtcnance Ca; e should be taken that the rekni valvc CaNNOT br isolated from the system when the oystem is cperadonal .-\ aim valve shoirc k%'ER Fon'e a sfljtof! valve or a plug clownsrresrn of fts cute' SS-M1011 A_VOO1 06/13 TESTANDRAIN" is registered trademark of AGE Manufacturing Inc. Model 1011 A C USTED ® TE TAN DRAIN® Model 101 IA 300 PSI Bronze Ball Valve, Model 7000 Pressure Relief Valve APPROVED Factory Rated at 175 PSI with other setting available Model 1011 A - Front View SIZE A B C 0 E F G H '14' 79A6 11/2 23A6 35/8 3 /8 ' 113A6" 49/16 63/8" It 91 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 79A&' 11/2" 2A&' 3/8" 3/8" 113A6" 4 /16" 6/8" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 11/411 715A6" 111A6" 29/16" 41/4" 3/8" 115/16" 5A6" 71/2" (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 1½" 815A6" 113A6" 31/4" 51A6" 3/8" 25/8" 81/4" 1O/8" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 2" 815A6 113A6" 31/4" 51A6" 3/8" 25/8 81/4" 1O/8" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) The Model 1011 provides the following... FrOITI the 2013 Edition of NFPA 13 Chapter 8 i6.2.4.1 Provisions sha)l he made to properly drain all parts of the system Chapter 8 16.2.4.2 Drain connections, interior sectional or fioor control valve(s)-- & 8 16.2.4.3 shall be provided with a drain connection having a minscum size as shown in Table 8.16.2.4.2 Chapter .3 162.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drum. Chaote A.&17.4.2 (Wet Pipe System) test connection is permitted to terminate Into a drain capable of acceptng to)) flovv.. us1ni an aporoved sight test conncctcrrm coimtainirrg a smooth bore car rcslorr_rosistaflt orifice giving a flow equivalent to one srrnkler. Chapter 8.1 7.4.2.2 The test connection valve shall he aczessiOle. Chapter 8 17.4.2.4 shall be permitted to be installed in any location.., downstream of the waterflovi alarm. Chapter 8 17.4.3.1 Dry Pipe System), a trip test connection not less than 1 in, d,ameter, terrrminatmng in a smooth bore con'usiorr-resistant orifice, to provide a flow eauivalent to one sprv'kler Chapter 8.17 4 3 2 The trip test connection.., with a shutoff va)ve and plug not )ess than 1". at least one of which shall be brass Chapter 7.1.2 a wet pipe systern shall he provided with a listed ie)ief valve set to operate at 175 PS) or 10 PS) in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3* A listed relief valve of not less than 'i" in size shall be provided on the discharge side of the pressui'ereducmnq valve set to operate at a pressure not exceeding ruled pressure of the system. Chapter A.81 6.1.2.3 consideration should be given to piping the discharge from the (pressure relief') valve USA Patent # 4741361 and Other Patents Pending AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com 3vm!rbIe on 1 "h" :c 2' 13e ur:ts Cr' 'A'.ahbI 0" ........o Dimensions Model 1011 - Plan View 4+ TO B DRAIN + Orifice Sizes 7/ E).C. ESFR*, and K25** Materials Handle ...............Steel Stem...................Rod Brass Ball ..... ................. CF (3m ass Body ........ .......... Bronze Valve Seat ..........tmprecaec Tef!are' Indicator Plate . . Steel Relief Valve ........Bronze Bypass Fittings... Brass Bypass Tubing .... N')obrad Approvals UL and ULC Listed: (EX4019&EX4533) FM Approved NYC-BSA No. 72087SM MADE INU.$J. Job Name: Architect: Engineer: Contractor: Description Manufactured from .020" white coated aluminun ,,, - are screen printed with a fade resistant red ink. Each sign is shipped with a clear protective plastic coating which can be re- moved at time of installation. Each sign type meets or exceeds NFPA13 requirements. All signs (except 7" round) are drilled in four corners to allow for easy installation. All signs (except 7" round) may be installed with sign chain or with any fastener that is suitable for the material that the sign is being attached. The 7" round bell signs are center drilled to allow for installation di- rectly to the bell gong assembly. Type "A" 9" x 7" Control valve signs are drilled with the same four hole pattern as Type "B" 6" x 2" signs to allow for attachment of Type "B" to Type "A". Installation Specifications Material: .020" aluminum with removable plastic coating Sizes: 6" x 2" x 6" x 7" 9" x 7" 12" x 10" 8.5" x 11" See current catalog for a full listing of all available signs. Installation of aluminum signs is accomplished by several methods. The most common installation procedure is to use #16 Single Jack chain to hang the sign on the area being identified. Since all of the above mentioned signs are predrilled at all four cor- ners, the last link of the chain can be opened and hooked through the top holes on the signs and hung on the ap- propriate valve or piping. The signs may also be fastened to a flat surface with fasteners appropriate to the base mate- rial. (The 9" x 7" Fire Alarm Bell sign must be drilled if it is to be attached directly to the bell gong.) ©1996-2009 Fire Protection Products, Inc (FPPI) Fire Protection Products, Inc FPPI 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 For questions: 1 800 344-1822 • 1 800 344-3775 fax www.fppi.com No. Description Box Qty. 02-002-00 Blank Sign w/border6" x 2" 1000 02-006-00 Air Control, 6" x 2" 1000 02-010-00 Air Line, 6" x 2" 1000 02-014-00 Alarm Line, 6" x 2" 1000 02-018-00 Alarm Test, 6" x 2" 1000 02-022-00 Anti-Freeze System 6" x 2" 1000 02-023-00 Anti-Freeze System 5" x 7" 1000 02-024-00 Auto Sprinkler Shut-Off 12" x 10" 1000 02-026-00 Auxiliary Drain, 6" x 2" 1000 02-034-00 Control Valve, 6" x 2" 1000 02-036-00 Control Valve, 4" x 6" 1000 02-037-00 Control Valve, 5" x 7" 1000 02-038-00 Control Valve, 9" x 7" 500 02-042-00 Drain, 6" x 2" 1000 02-046-00 Drain Valve, 6" x 2" 1000 02-050-00 Dry Standpipe 6" x 2" 1000 02-051-00 Fire Dept. Connection 6" x 2" 1000 02-053-00 Excess Pressure Pump, 6" x 2" 1000 02-054-00 Entire System, 6" x 2" 1000 02-055-00 Fire Alarm Bell, 9" x 7" 500 02-056-00 Fire Alarm Bell, 7" Round 500 02-057-00 911 Fire Alarm Bell, 7" Round 500 02-058-00 F.S. Valve Do Not Close, 6" x 2" 1000 02-060-00 Fire Sprinkler Riser Inside, 6" x 2" 1000 02-062-00 From City Main, 6" x 2" 1000 02-066-00 In This Building, 6" x 2" 1000 02-070-00 In This Section, 6" x 2" 1000 02-074-00 Inspectors Test, 6" x 2" 1000 02-077-00 Hydraulic System, 5" x 7" 1000 02-081-00 Hydraulic System, 8-1/2" x 11" 1000 02-082-00 Main Control, 6" x 2" 1000 02-086-00 Main Drain, 6" x 2" 1000 02-091-00 Multi-use System, Warning, 5" x 7" 1000 02-092-00 Normally Closed, 6" x 2" 1000 02-096-00 Normally Open, 6" x 2" 1000 02-098-00 Open Sprinkler, 6" x 2" 1000 FIRE SPRINKLER RISER INSIDE AUTOMATIC SPRINKLER SHUT-OFF VALVE LOCATED FT1 OPPOSITE THIS S11 THROUGHOU I BUILDING I ' I Sprinkler Identification Signs FPPI's Sprinkler Identification Signs are manufactured of aluminum, painted white then printed with 'fade resistant" red ink. Each sign is drilled for easy installation and is plastic coated to prevent scratching of finish during shipment and final installation. Designed in accordance with NFPA requirements. ©1996-2009 Fire Protection Products, Inc (FPPI) •• Fire Protection Products, Inc FPPI 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 For questions: 1 800 344-1822 • 1 800 344-3775 fax • www.fppi.com Installation Select the correct Spare Sprinkler Head Cabinet in accordance with the Automatic Sprinkler Systems Handbook. As per the 1989 Edition the correct number of spare sprinkler is as follows: "0-300 sprinklers, not less than 6 300-1000, not less than 12 1000 or more, not less than 24. Stock of spare sprinklers shall include all types and ratings installed."* Once the correct Spare Sprinkler Head Cabinet has been select- ed, installation is accomplished by inserting the correct fastener in each of the two holes inside the cabinet, securing the cabinet securely to the wall. The insert the correct number and type of sprinklers in accordance with the "handbook". *Final determination is subject to approval by the AHJ. Storage Cabinet Description Fire Protection Products, Inc. Spare Sprinkler Head Cabinets are designed to allow for spare sprinkler head storage as required by NFPA guidelines. The Spare Sprinkler Head Cabinets are available in six configurations. Three head, six head, six head ESFR, twelve head, twenty-four head and thirty-six head. All six styles are manufactured with "knockouts" to accommodate the most common size sprinklers. The shelf is located to allow for the storage of a typical sprinkler head wrench. Each cabinet is finished with a red enamel fi fish. Each spare head cabinet comes with a hinged door which remains closed to protect the spare sprinklers from the elements and features two holes on the back panel to allow for attachment to most surfaces utilizing the appropriate fasteners. Not intended for exposed or harsh environments. Specifications Material: Painted plain steel Finish: Red enamel Styles: 3 Spare sprinklers, 1/2 or 3/4 6 Spare sprinklers, 1/2or314 6 Spare, ESFR, 1/2 , 3/4 or 1" 12 Spare sprinklers 1/2or314 24 Spare sprinklers 36 Spare sprinklers ©2000-2007 Fire Protection Products, Inc (FPPI) Fire Protection Products, Inc FPPI 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 For questions: 1 800 344-1822 • 1 800 344-3775 fax www.fppi.com ECS Ejector Automatic Air Vent (PAV-W) Specifications EI,w EI Stock Number: PAV-W PAV-WS (Supervised) Service Pressure: Up to 175 PSIG System Connection: 1" NPT Male Temperature Range: 40°F to 120°F (4.5°C to 49°C) Dimensions: 14"(L) X 7"(D) X 7"(H) Weight: 8 Lbs Clear Height: 5" Patented redundant float design eliminates piping to a drain Support Hanger Not Required U.S. Pat. No. 8,636,023 General Description The ECS Ejector Automatic Air Vent (PAV-W/WS) is a device that provides automatic venting of trapped air in wet pipe fire sprinkler systems. As a fire sprinkler system is filled with water, trapped air migrates to the high point of the system near the vent installation location which allows for trapped air to be vented. Trapped air contains oxygen which is the primary cause of corrosion in fire sprinkler systems. Corrosion in wet pipe fire sprinkler systems is directly proportional to the amount of oxygen trapped within the system piping, so a reduction in trapped air will in turn reduce the internal corrosion activity of the fire sprinkler system. Venting the trapped air in a wet pipe sprinkler system can also decrease water delivery time and reduce false water flow alarms. The ECS Ejector Automatic Air Vent must be installed as shown on the engineering design documents, if a location is not provided install the vent at an accessible high point on the fire sprinkler system remote from the system riser where gas can be vented and at a location that the pressure gauge provided for visual monitoring can be viewed from directly below. The PAV-W/WS is also equipped with brass components that allows the device to be installed in areas subject to external corrosion. The float mechanism on the ECS Ejector Automatic Air Vent will automatically close when water reaches the vent and the redundant design eliminates the need to plumb the PAV-W/WS to drain. If the primary air vent valve allows any significant amount of water to leak past the second air vent valve will close preventing water from discharging and provide a system pressure reading on the pressure gauge. This condition will be an indication that the primary automatic gas vent valve has failed and requires service or replacement. The pressure gauge is designed to be visible from the floor below the ECS Ejector Automatic Air Vent from a distance of approximately 30 feet. There are two available models of the ECS Ejector Automatic Air Vent: the PAV-W and the PAV-WS. The units both operate as described previously, but the PAV-WS includes a wiring connection to a monitoring circuit. A single contact rated 24VAC/DC @ 2A for electronic monitoring with an end of line resistor (EOLR) must be installed according to the wiring diagram in Figure 1 to electronically monitor the PAV-WS. A notification from the PAV-WS indicates that the pressure gauge on the bottom of the vent assembly has a system pressure reading due to a failure of the primary float valve which renders the ECS Ejector Automatic Air Vent inoperable. Engineered Corrosion Solutions 11336 Lackland RoadS St. Louis, MO 63146 Phone 1-314-432-1377W www.ecscorrosion.com ECS EJECTOR AUTOMATIC AIR VENT April 2016 - Rev 3 1 Installation Instructions Maintenance Instructions 1 The ECS Ejector Automatic Air Vent is equipped with an isolation ball valve to be connected to the fire sprinkler system. Once the PAV-W/WS has been assembled at the provided union (see Figure 1), the contractor shall install a 1" outlet (welded or mechanical) to connect the vent assembly to the sprinkler system. 2 Install the PAV-W/WS vent assembly at the location provided by the engineering design documents in a level position at an accessible high point on the sprinkler system where trapped gas can be vented. NOTE: Piping to the vent assembly cannot be installed in a configuration that would trap water and prevent drainage to the sprinkler system; a water trap impedes the ability of the vent to remove gas from the fire sprinkler system. 3 When electronic supervision is specified the PAV-WS must be utilized instead of the PAV-W (see Figure 1) and an addressable monitor module with an end of line resistor must be provided in accordance with NFPA 72. 4 Inspection of the vent assembly should be performed after installation and hydrostatic testing of the fire sprinkler system. Inspection should be performed periodically thereafter in accordance with the applicable NFPA codes and standards and/ or the authority having jurisdiction. The ECS Ejector Automatic Air Vent shall be inspected annually at minimum. While isolation ball valve is in the open position check for air/water leaks. Check the pressure gauge on the bottom of the vent assembly for a system pressure reading. If a system pressure reading is detected the primary vent valve may require service or replacement. While isolation ball valve is in the closed position the inspection must check for blockage in the "Y" strainer and the discharge orifice. Ooeratin2 Instructions Once the fire sprinkler system has been hydrostatically tested, open the isolation ball valve on the PAV-W. Trapped gas should be expected to immediately vent from the device if the system has been re-filled with water. The isolation ball valve shall remain in the open position to allow for venting of any additional trapped gas remaining in the system that may migrate to the vent location. Water traps that would restrict operation of the ECS Ejector Automatic Air Vent can be cleared by closing the isolation ball valve and removing the "'1" strainer plug. Once the water trap has been removed, replace the "Y" strainer plug and reopen the isolation ball valve. NOTE: Patented redundant float design eliminates Gas Vent Valve Replacement piping the PAV-W to a drain Plumbing the PAV-W/WS to drain is not renijirerl. FIGURE 1 - Wiring Diagram INSTALLATION NOTES: If Monitored By The Building Fire Alarm System, Provide One Addressable Monitoring Module To Monitor The Ejector Automatic Air Vent. Connect The Ejector Automatic Air Vent To The Addressable Monitor- ing Module. Supervise The Circuit Using An End-Of -Line (E.O.L.) Resistor In Accordance With NFPA 72. PERIN Occasionally during venting operations a small amount of water may leak past the primary gas vent valve and collect in the intermediate plumbing. This is considered normal and not a failure of the valve. However, if inspection reveals a system pressure reading then the primary vent valve may require replacement. Please contact Engineered Corrosion Solutions for replacement parts and instructions. Engineered Corrosion Solutions 11336 Lackland Road • St. Louis, MO 63146 Phone 1-314-432-1377 www.ecscorrosion.com ECS EJECTOR AUTOMATIC AIR VENT April 2016 - Rev 3 2 Primary and Seconds Gas Vent Valves "Y" Strair NJ Figure 2 - ECS Ejector Automatic Air Vent Outline Drawing Pressure Gauge Figure 3 - ECS Ejector Automatic Air Vent Installed on Sprinkler System 1" Connection to Sprinkler System must NOTE: Piping to the vent assembly cannot be installed in a configuration that would trap water and prevent drainage to the sprinkler system; a water trap impedes the ability of the vent to remove gas from the fire sprinkler system. NOTE: Patented redundant float design eliminates piping vent to drain. Engineered Corrosion Solutions• 11336 Lackland Road• St. Louis, MO 63146 Phone 1-314-432-1377 www.ecscorrosion.com ECS EJECTOR AUTOMATIC AIR VENT April 2016 - Rev 3 Engineered Corrosion SolutionsT M Complete Corrosion Control.