Loading...
HomeMy WebLinkAbout5940 DARWIN CT; ; FPC2020-0132; PermitPERMIT REPORT G 4L(7city of arlsbad Print Date: 06/10/2021 Permit No: FPC2020-0132 Job Address: 5940 DARWIN CT, CARLSBAD, CA 92008-7395 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2121201700 Track #: Applied: 07/28/2020 Valuation: $11,627.50 Lot #: Issued: 08/12/2020 Occupancy Group: Project U: Finaled Close Out: 06/10/2021 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: Description: PRATT & WHITNEY PROJECT METEOR PHASE 3 -SPRINKLER TI (15 HEADS) Applicant: FPContractor: COSCO FIRE PROTECTION COSCO FIRE PROTECTION INC MICHAEL LOVELY 1075 W LAMBERT RD 4990 GREENCRAIG LN BREA, CA 92821-2944 SAN DIEGO, CA 92123-1673 (858) 444-2000 (858) 444-2000 x1727 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov San Diego Branch Office .0099 06 cosco 4990 Greencraig Lane S. 5.S•. San Diego, CA 92123 's.' I Fire Protection (858) 444-2000 fax: 444-2056 CALk.:C-16#577621 www.coscofire.com MATERIAL SUBMITTAL Date: 07/22/20 Pratt & Whitney 5940 Darwin Ct. Carlsbad, CA 92008 JOB # 10.CA_5501 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted by: M.J. Los Angeles • San Francisco • Orange • Fresno • San Diego • Seattle Bulletin 013 November 2019 R 11ab Model F156 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall ® Models Fl Series Standard Response Sprinklers C CD Model F156 Recessed Sprinkler Types Pendent/Fl/F2/FP Horizontal Sidewall Model F142, FIXLH & F128 Sprinkler Types Standard Upright Standard Pendent Model F142, F1XLH & F128 Recessed Sprinkler Types Pendent/F1/F2/FP Approval Organizations Underwriters Laboratories Inc. and certified for Canada (cULus) Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS Schadenverhutung GmbH EC Certificate: 0786-CPD-40237 (RA1314) 0786-CPD-40253 (RA1 325) 0786-CPD-40254 (RA1 375) UL Listing Category Sprinklers, Automatic & Open (VNIV) Product Description The F156, F142, F1XLH & F128 Series Glass Bulb Sprinkler combines the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. Whether installed on exposed piping or in an office ceil- ing, it is functional and attractive. Beautifully versatile is the description for the Reliable Models F156, F142, F1XLH & F128 Series Recessed glass bulb sprinkler. Recessing the F156, F142, F1XLH & F128 Series enhances its already low profile decorative appearance, and facilitates a rapid and perfect installa- tion. The recessed escutcheon of the Models F156, F142, F1XLH & F128 are highly adjustable. The two piece con- struction makes field installation a very easy and rapid task. This also allows ceiling panels to later be removed without shutting down the fire protection system, thus fa- cilitating maintenance of above ceiling services. PendentjF1/F2 Horizontal Sidewall Pendent/FP Pendent F1/F2 Pendent FP The F156, F142, F1XLH & F128 Series Automatic Sprin- kler utilizes a 5.0 mm frangible glass bulb. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid phase and in the vapor phase. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distribute the discharging waift The F156, F142, F1XLH & F128 Series Sprinkler t perature rating is identified by the color of the glass bulb capsule as well as frame color where applicable. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Technical data: Thread Max. Mm. Temperature Models Nominal K-Factor Response Size Working Working Rating Finish Pressure Pressure F156 5.6 (80 Metric) 250 P51* ½" NPT See See F142 FIXLH 4.2 (60 Metric) Standard (R½) 7 PSI "Temperature "Finish Table" 175 PSI Ratings" Table F128 2.8 (40 Metric) Material Data: Frame Deflector Load Screw Pintle Cup Washer Bulb CDA Alloy 260, CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 DZR Brass CDA Alloy 220 or or or coated with PTFE Adhesive Glass QM Brass or CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape CDA Alloy 510 Model F156 uoriaht. oendent, and recessed oendent srinkIers (SIN RA1325 and RA1314) are cULus Listed for 250 psi (17 bar). Model F156, Upright, Pendent & Conventional Sprinklers Model F142, FIXLH & F128 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench or Model W2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size Nominal K-Factor Sprinkler Height Approval Organization Sprinkler Identification Nu mber.' (SIN) I I Upright I_Pendent US I Metric Standard-Upright (SSU) and endent Deflectors Marked to Indicate Position ½" (15mm) (1) Y2" NPT (R1/2)5.6 I 80 1 2.25" (57mm) 1,2,3,4,5 I 7/" (10mm) 1/2" NPT R/2)4.2 I 60 1 2.25" (57mm) 1 RA132326 RA13136 " (10mm) 1 1/2" NPT F/2) 1 2.8 I 40 1 2.25" (57mm) 1 1 RA1321 26 I RA13116 Conventional-Install in Upright or Pendent Position 15mm I 1/2" NPT (R1/2) I 5.6 I 80 I 57mm I 3, 4 5 I RA13755 "Refer to Bulletin 024 for Special Response Sprinklers (F1S5-56) cULus Listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM Approved sprinkler. ----- Polyester coated LPCB & VdS approved sprinkler RA1325, RA1314 & RA1375. Electroless Nickel PTFE Plated - UL listed Corrosion Resistant Upright Pendent ConvenonaJ Model F156, F142, FIXLH & F128 Recessed Pendent Sprinklers1 Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size Nominal K-Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2" (15mm) 1/2" NPT (R1/2) 5.6 80 2.25" (57mm) RA13142 7/" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) RA13132 3/8" (10mm) ½" NPT (R1/2) 2.8 40 2.25" (57mm) RA13112 Refer to escutcheon data table for approvals & dimensions Electroless Nickel PTFE Plated - cULus listed Corrosion Resistant 2 114' HOLE OLE [STONE] IS/IA' 00 r 1 AILS LS INtER -- ) __- '0 /2' REOUCER WRENCH _II ON' - 'ADJUE I A 2 21132'- RECESSED PENDENT W/F1 OR F2 ESCUTCHEON 'SPRINKLER TOT FM APPOOLRU WITH F? ESCUTCHEON FACE OF P177100 TO FACE OF CEILING DIMENSION F FSEIRCNFON AT MAXIMUM RECESS - ,74o 25] AT DIN/OUR RECESS - 3/870.O,N,H] 1 F0 ESCUTCHEON AT MAXIMUM RECESS - 3/4'[lM(TN.] AT MINIMUM RECESS - 3/87953 F ESCUINUFCAS AT MAXIMUM RECESS - 7/8722.2,] AT MINIMUM RECESS - -5/8741.3N] AT MAXIMUM RECESS - /8 '[20 6/TIlT AT MINIMUM ACCESS - It -5/8 74 AN,,, L------J.----S-TTJ L----------x 112- REDUCER - 2 5/8' 004. (66.7oR] HOLE IN CEILING 2 S/tN' 004. [58.7REm1 CUP FACE OF FITTING TO FACE OF CEILING DIMENSION AT MAXIMUM RECESS AT MINIMUM RECESS 1— 112'[.38--] [2750 BTRTRJ j I AT MAXIMUM RECESS - 9116[14,3-] AT MINIMUM RECESS - '[25.Ammj ADJUSTMENT 3 I/A' 000. [82.MmTR] -1 RECESSED PENDENT W/FP ESCUTCHEON OAOSOAO 'SPRINKLER NOT FM APPROVED WITH FP ESCUTCHEON [ijj 3. S Model F156 Vertical Sidewall Sprinkler Installation Wrench: Model W2 Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy O.S. Patent No. 6,374,920 Sprinkler Type Deflector to Ceiling Distance (Mm. - Max.) Upright 4" (102mm) - 12" (305mm) Pendent 4" (102mm) - 12" (305mm) Installation Data: Vertical Sidewall Nominal Orifice Thread Size I Nominal K Factor I Sprinkler I Height Approval Organizations I Sprinkler Identification I I US I Metric Numbers (SIN) ½" (15mm) ½" NPT (R½) 5.6 80 2.25" (57mm) 1, 2,3 (1) LPC Approval is pendent only, 57°C through 141°C ratings. 2 cULus Listed corrosion resistant (Polyester coated) sprinkler. 3 cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead. (4) Electroless Nickel PTFE Plated - cULus listed corrosion Resistant Model F156 Horizontal Sidewall Sprinkler Deflector HSW Installation Wrench: Model W2 Sprinkler Wrench Horizontal Sidewall Installation Data:Horizontal Sidewall I I I 15/16 DlA.jj)J _lltllllIt1.r-i_ [1OI.6m-304.8] [49.2mm] lJtillT 2 27/32 0/A. CEILING TO I [72.2mm] DEFLECTOR TURN COLLAR UNTIL -' TIGHT AGAINST SPRINKLER ff Fl ESCUTCHEON WRENCH ROSS. 3/4719mm] ADJUSTMENT F2 ESCUTCHEON 112-[12,7-1 ADJUSTMENT RECESSED HSW W/fl OR F2 ESCUTCHEON (I) FM APPROVED FOR 4 - 6 [101.6MM - 752.4MM] CEILING TO DEFLECTOR. rinKlers use installation wrenc FM and cULus permits use with El or F2 escutcheons for "Light Hazard" only. FACE OF FITTING TO FACE OF CEILING DIMENSION F? ESCUTCHEON AT MAX/MUM RECESS = 1"[25.4--] AT MINIMUM RECESS = 3/879.5mm] F2 ESCUTCHEON At MAXIMUM RECESS = 3/4779mm] AT MINIMUM RECESS 3/879.5mm] 1-2 114" HOLE 0/A. I [57.2m,-,] I" X 1/2" REDUCER Fl ESCUTCHEON AT MAXIMUM RECESS = 1-3/8"[34.9mm] AT MINIMUM RECESS 2-1/16752.4mm] V F2 ESCUTCHEON I AT MAXIMUM RECESS = I -5/8741.3mm] AT MINIMUM RECESS = 2-7/16752.4mm] oI [3.2mm] Nominal K Factor Sprinkler Height __________________ Approval Organizations Sprinkler Nominal Orifice Thread Size Identification US Metric Light Hazard Ordinary Numbers (SIN) Hazard ½" (15mm) ½" NPT (R1/2) 5.6 80 2.63" (67mm) 1,2 1 RA1335"123141 'cULus Listed corrosion resistant (Polyester coated) sprinkler. cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead. Wpolyester coated FM approved sprinkler. 4) Electroless Nickel PTFE Plated - cULus listed Corrosion Resistant 4. Application Model F156, F142, F1XLH, F128& Model F156, F142, F1XLH & Fl 28 Recessed sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preacon. Care must exercised that the orifice size, temperature rang, deflector style and sprinkler type are in ac- cordance with the latest published standards of the National Are Protection Association or the approving Authority Having Jurisdic- on Installation. lrebbon Model F156, F142, F1XLH & F128 Series sprinklers are stan- dard response sprinklers intended for installation as specified in NFPA 13. They must also be installed With the Model W2 Sprinkler Wrench specifically designed by Reliable for use with these sprin- klers. The Model F156, F142, F1XLH & F128 Recessed Sprinklers are to be installed with a maximum recess of 3/4 inch (19mm). The Model Fl, F2, and FP Escutcheon illustrated are the only recessed escutcheon to be used with the Model F156, F142, F1XLH & F128 Recessed Sprinklers. The use of any other recessed escutcheon Will void all approvals and negate all wan-anes. When installing Model F156, F142, F1XLH & F128 Recessed Sprinklers use the Model GFH2 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Note: A leak tight ½" NPT (R½) sprinkler joint can be obtained with a torque of 8- 18ff-lbs (11 -24 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impair- ment of the sprinklers. Glass bulb sprinklers have orange covers to protect the bulb dur- ing the installation process. REMOVE THIS PROTECTION ONLY AFTER THE SYSTEM HAS BEEN HYDROSTA11CALLY TESTED AND, WHEN APPLICABLE, THE ESCUTCHEONS HAVE BEEN INSTALLED. RASCO wrenches are designed to install sprinklers when covers are in place. Ordering Information Specify: Sprinkler Model Sprinkler Type Nominal K-Factor Temperature Rating Sprinkler Finish Thread Type: [½" NPT] [ISO 7-1R½] Escutcheon Finish (where applicable) Note: When Models F156, F142, F1XLH & F128 Recessed Sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Escutcheon Data (1) (1) SIN: RA1335 - cULus and FM permits use with Fl or F2 escutcheons for light hazard only. Maintenance The Model F156, F142, F1XLH & Model F156, F142, F1X- LH & F128 Recessed Sprinklers should be inspected and the sprinkler system maintained in accordance with NFf3A. 25. Do not clean sprinklers with soap and water, ammo or any other cleaning fluid. Replace any sprinkler which h been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause im- proper operation or non-operation. Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color DC T Ordinary 57 135 100°F (38°C) Orange Ordinary 68 155 100°F (38°C) Red Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green High 1 141 286 225°F(107°C) Blue Extra High" 182 360 300°F (149°C) Mauve Ultra High 1)(2) 260 500 1 475°F (2460c) Black Not available for recessed Sprinklers. cULus listed for SIN RA1325 and RA1314 only. Maximum Working Pressure 175 psi (12 bar) SIN RA1325 & RA1314 cULus listed for 250 psi (17 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finishes Sprinkler Escutcheon Bronze Brass Chrome Chrome Polyester Coated (6)(7))9) White Painted Special Appliritipn Finishes Sprinkler Escutcheon Electroless Nickel PTFE(3X10) Electroless Nickel PTFE Bright Brass(') Bright Brass Black Plated Black Plated Black Paint 39 Black Paint Off White (3)(9) Off White Chrome Dull Chrome Dull Lead Wax Wax Over Other colors and finishes are available on special order. Consult factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. 2 °F (93°C) maximum. 3) UL and ULC listed only. 4 155°F to 2°F (68°C to 93°C) ratings only. 5 286°F (141°C) sprinklers may be coated for ambient conditions not exceeding 150°F (66°C). cULus listed "corrosion resistant" applies to SIN Number RA1325 (Upright) RA1323 (upright), RA1321(Upright), RA1335 (HSW), RA1385(VSW) and RA1314 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approved finish as "Polyester Coated" applies to SIN number RA1314, RA1335 & RA1325 in standard black or white. (9) FM Approved finish applies only to SIN number RA1335 & RA1385. (9) LPCB and VdS Approved finish applies only to RA1325, RA1314 and RA10 (10)cULus listed Corrosion Resistant applies to SIN RA1325 ,RA1314 ,RA1 RA1313 ,RA1321, RA1311, RA1385 and RA1335 Finish1 Standard Reliable ... For Complete Protection 0 eliable offers a wide selection of sprinkler components. Following are some of the many recision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years. Reliable Reliable Automatic Sprinkler Co., Inc. Recycled (800) 431-1588 Sales Offices Paper (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 11/19 P/N 9999970299 SCHEDULE 10 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES In. mm in. mm in. mm Ibs./ft. kg/rn CRR Lift 11/4 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 1'/2 1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 21/2 2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 4 4,500 114.3 4.260 108.2 .120 3.05 5.62 8.37 1.6 19 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 6 6.625 168.3 6.357 161.5 .134 3.40 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). SCHEDULE 40 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES In. mm In. 1 mm In. mm Ibs./ft. kg/rn CRR Lift 1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 11/4 1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 1Y2 1,900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 2 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 7.0). & C@ FM Approved and Fully Listed Sprinkler Pipe Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, C-UL and FM Listed. Approvals and Specifications Both products meet or exceed the following standards: ASTM A135, Type E, Grade A (Schedule 10) ASTM A795, Type E, Grade A (Schedule 40) NFPA13 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe up to 6" receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black, or with hot-dip galvanizing, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is also UL Listed. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: Fj BLACK El HOT-DIP GALVANIZED Wheatland Tube 700 South Dock Street Sharon, PA 16146 P 800.257.8182 1 F 724.346.7260 1 info@wheatland.com I wheatland.com 111L hi i DUCTILE IRON 90 DEG. ELBOW NOMINAL SIZE (INCH) ITEM CODE # ' MAX. WORKING P.S.I. 'DIMENSIONS WEIGHT' A B EACH PIECE I DB90033 500 1.50 1.50 0.62 1114 DB90044 500 1.75 1.75 0.90 11/2 DB90055 1 500 1.94 1.94 1.20 2 1 DB900661 500 2.25 2.25 1.85 I DUCTILE IRONI 11 ijjil DEG. ELBOW NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WEIGHT A B EACH PIECE 1X1/2 DB90031 500 1.26 1.36 0.44 1X314 DB90032 500 1.37 1.45 0.52 I 114X112 0B90041 500 1.34 1.53 0.64 I 114X3/4 DB90042 500 1.45 1.62 0.72 I 114X1 DB90043 500 1.58 1.67 0.75 I 1/2X1 DB90053 500 1.65 1.80 0.92 I 1/2X1 1/4 DB90054 500 1.82 1.88 1.08 2X1/2 DB90061 500 1.49 1.88 1.08 2X3/4 DB90062 500 1.60 1.97 1.24 2X1 DB90063 500 1.73 2.02 1.40 2X1 1/4 DB90064 500 1 1.90 2.10 1.52 2X1 1/2 DB90065 500 1 2.02 2.16 1.65 DUCTILE IRONCIIDEG. ELBOW NOMINAL SIZE (INCH) ITEM CODE # MAX. WORKING P.S.I. I DIMENSIONS I WEIGHT I A B EACH PIECE I DB45033 500 1.12 1.12 0.46 11/4 DB45044 1 500 1.29 1.29 0.73 11/2 DB45055 500 1.43 1.43 0.92 2 DB45066 500 1.68 1.68 1.50 DUCTI LE I RON STRAIGHT ii NOMINAL SIZE (INCH) ITEM MAX. CODE WORKING # P.S.I. DIMENSIONS WEIGHT I - A B EACH PIECE I DT333 500 1.50 1.50 0.85 11/4 DT444 500 1.75 1.75 1.22 11/2 DT555 500 1.94 1.94 1.55 2 DT666 500 2.25 2.25 2.45 STAR®PIPEPRODUCTS D.I. THREADED FITTINGS LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 Ductile iron threaded fittings are UL, ULC listed and factory mutual approved for 500 psi service. Ductile iron per ASTMA536 grade 65-45-12. Dimensions conform to ANSI 1316.3 class 150. Threads are NPT per ANSI/ASME 131.20.1. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittingd should be tightened theree turns beyond hand tight, but no more than four turns. S -A- • DUCTILE IRON COUPLINGI I NOMINAL' ITEM ' MAX. 1DIMENSION 1 WEIGHT I SIZE CODE WORKING EACH (INCH) # P.S.I. A PIECE I DCL033 500 1.67 0.40 11/4 DCLO44 500 1.93 0.57 11/2 DCL055 500 2.15 0.75 2 DCLO66 500 2.53 1.15 DUCTILE I RON RED.ii1UJ JUl NOMINAL ITEM SIZE CODE (INCH) # MAX. WORKING P.S.I. DIMENSION WEIGHT EACH PIECE A IXI/2 DRC03I 500 1.69 0.39 1X3/4 DRC032 500 1.69 0.53 Page 21 DUCTILE II (i1 CROSS I NOMINAL SIZE (INCH) I ITEM CODE # I MAX. WORKING P.S.I IDIMENSIONS I WOGHT I - A - B EACH PIECE I DX033 500 1.50 1.50 0.98 11/4 DX044 500 1.75 1.75 1.50 11/2 DX055 500 1.94 1.94 1.90 2 DX066 500 2.25 2.25 2.95 I 1/4X1 DX043 500 1.58 1.67 1.27 I 1/2XI DX053 500 1.65 1.80 1.48 2X11 DX063 1 500 1.73 2.02 1 2.10 r - I - OUTSIDE HEAD INSIDE HEAD DUCTILE I RONIBUSHINGS NOMINAL SIZE (INCH) ITEM CODE # DIMENSIONS STYLE I C FAC I I A B lxl/2 DBUSH3I 0.75 0.25 1.42 OUT 0.22 1x3/4 DBUSH32 0.75 0.25 1.42 OUT 0.171 I 114x1 DBUSH43 0.80 0.28 1.76 OUT 0.28 I 112x1 DBUSH53 0.83 0.31 2.00 OUT 0.44jJ I 1/2x1 1/4 DBUSH54 0.83 0.31 2.00 OUT 0.30 2x1 DBUSH63 0.88 10.41 1.95 IN 0.66 2x1 1/4 DBUSH64 0.88 10.3412.48 JOUT 0.72 2x1 1/2 DBUSH65 0.88 10.3412.48 JOUT 10.61 DUCTILE IRON REDUCING TEE NOMINAL_ _J MAX P.S.I.___ WORIKING I':[c1:i EACH PIECE - '4'I'R mmaLl 4'I'1 F.1 RUM kI InK IfrEiIIL MAIM, I' MUM Km- !* Ifr4IVLfr'i 19 T'P • • mal vi'iva ' ' Vl4 Ifr4IMJWMn 4'I'SLUM IfrIIL ERUIRM ONE'I' 1 - - 'ii* i'i' Kam 1111IM11111 ME Ulm 1111191-1m 4I1L iI1i Um KKR I'Z['!' MEL oi v/' MULUM .-1111 R&M Illw1l"m ['I Mulmstammallm S DUCTILE II s] I NOMINAL' SIZE (INCH) ITEM CODE ' MAX. WORKING P.S.I. IDIMENSION I WEIGHT EACH PIECE A I DCP003 500 1.16 0.32 11/4 DCPOO4 500 1.28 0.43 11/2 DCP005 500 1.33 0.60 2 DCP006 500 1.45 0.91 S D.I. THREADED FITTINGS STAR®PIPE PRODUCTS * (~~ <*> S LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 Page 22 FireLock® Fittings ® <&> @ ILPCBI EdS See Victaulic publication 10.01 for details FireLock® products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees are a CAD-developed, hydrodynamic design that has a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Style 005 and Style 009 FireLock couplings. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Fitting Coating: Orange enamel. Optional: Hot dipped galvanized. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. REV H j4tta uiicr 10.03 1 IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS FireLock® Fittings DIMENSIONS ICtoE1 to El Cto D T to to E NO. 001 NO. 003 NO. 002 NO. 006 S S www.victaulic.com \.4#1fc;taUuic: VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.03 2 REV H IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS FireLock® Fittings FLOW DATA 1 ¼ 1.660 1.5 1 0.8 3.7 I 1.5 32 L 42.4 - 0.5 Ii1 .1 .5 1 ½ 1.900 2.2 I 1.1 5.5 2.2 40 48.3 0.7 j 0.3 1.7 0.7 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 --2.6 1.1 21/2 2.875 4.3 2.2 I 10.8 I 4.3 65 I 73.0 1.3 I 0.7 3.3 j 1.3 3.000 4.5 2.3 11.0 4.5 76.1 mm 76.1 I 1.4 0.7 3.4 1.4 t3.500 5.0 2.6 13.0 5.0 80 - 88.9 1.5 0.8 4.0 1.5 'r 4.250 6.4 3.2 15.3 6.4 108mm 108.0. 2.0 0.9 4.7 2.0 - -. -- 1. _. -+ --- 4 4.500 6 - .8 3.4 I 16.0 6.8 100 114.3 2.1 1.0 j 4.9 2.1 ----- -- 5 5.563 8.5 4.2 21.0 8.5 125 . - .41.3 2.6 - 1.3 -- i4 26 6.250 9.4 4.9 25.0 9.6 159mm 158.8 I 2.9 1.5 7.6 2.9 - 6 6.625 10.0 5.0 25.0 10.0 150 I 168.3 , 3.0 1.5 - '-4-- -.--- ------------ 7.6 3.0 8 8.625 13.0 'F 5.0 1 33.0 13.0 200 219.1 4.0 I 1.5 I 10.1 4,0 t The flow data listed is based upon the pressure drop of Schedule 40 pipe. S www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF vICTAuLIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. RFV H 4tauIicr 1O.O : FireLock® Fittings GENERAL NOTES NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009 and Style 009V couplings, use FireLock No. 006 end caps containing the EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V couplings. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. S S III 111111111111111111111 I 11111111 III S WCAS-7MX2JY For complete contact information, visit www.victaulic.com 10.03 1539 REV H UPDATED 1/2009 ictauIic VICTAULIC IS REGISTERED TRADEMARK or VICTAuLIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.03 FireLock® Rigid Coupling STYLE 005 S WITH VIC-PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) FireLock® Style 005 rigid coupling has a unique, patented angle-pad design which allows the housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. Support and hanging requirements correspond to NFPA 13 Sprinkler Systems. Angle-pad design permits assembly by removing one nut/bolt and swinging the housing over the gasket. This reduces components to handle during assembly. Style 005 FireLock coupling are designed and recommended for use ONLY on fire protection systems. VicPlusTM Gasket System: In North America, Victaulic® offers a gasket system which requires no field lubrication on wet pipe systems that are hydrostatically tested. The Vic-PlusTM System (patented) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over- lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (1-100) for supplemental lubrication requirements and dry pipe fire protection system notes. § LPC and VdS Approved, see notes on page 4 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS PATENTED (PIus tGa7t 5 LISTING/APPROVALS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. "FM approved for service in 1 ½ -4" pipe. # UL Listed for service up to 4" pipe only. @ UL Listed for service up to 3' only. JOB/OWNER 5 System No. Location CONTRACTOR ENGINEER Submitted By Spec Sect Date Approved Para www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED, PRINTED IN THE USA. DI I -IiIiii Ac-ta-ulill in Al I IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 1u.0 FireLock® Rigid Coupling STYLE 005 WITH VIC-PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) DIMENSIONS 1¼ ' 1.660 32 42.4 1½ 1.900 40 48.3 2 2.375 50 603 212 2.875 65 73.0 76.1 mm [ .000 761 -- 3 3.500 80 88.9 4 4.500 100 1143 108.Omm 4.250 108.0 5 5.563 125 141.3 133.0mm 5.250 133.0 5.500 139.7 mm 139.7 6 _6625- _150 168.3 159.0mm 1 6250 - 50 6500 165.1 mm 8 8.625 200 . 219.1 350 755 0.05 2413 3370 I 1.2 .f ---t 350 990 0.05 2413 ,L 4415 1.2 350 1550 I 0.07 2413 6900 4 1.7 2270 0.07 350 2413 10110 1.7 350 2475 0.07 2413 111010 1.7 350 3365 0.07 _. - 4 14985J - 1.7 350 5565 0.16 2413 J 24770 4255 4.1 300 0.16 2068 18940 -4.1 - 0.16 300 7290 2068 ,j 32445 4.1 300 6495 0.16 2068 _J 28900 4.1 0.16 300 7125 2068 31715 10340 4.1 300 0.16 2068 46020 4.1 300 9200 0.16 2068 L 40955 9955 4.1 j 0.16 300 2068 442j 4.1 300 17525 1 0.19 2068 78000 4.8 2 _3/8 x21/ 275 4.50 1.88 1.2 - : 70 114 148 0.5 2-/8 x 2/ 3.00 4,75 1.88 1.2 76 L,.121 148 0.5 3.50 5.25 1.88 1.6 2-/eX2/~ 89 I 133 148 0.7 4.00 5.75 1.88 1.9 102 ,146 148 .09 4.13 I 5.75 1.88 1.9 2-/8x2/2 146 148 0.9 - - 4.63 6.13 1.88 I 2.1 2-/8x2,/2 118 156 148 f 1.0 2- I/e x 21/2 575 4 7.25 2.13 3.1 146 . 184 54 f 1.4 5.63 2.13 3.1 24x2/ 143 184 54 -+ , 1.4 6.88 9.00 2.13 4.5 2-/2x3 175 I 229 54 -1 2.0 6.63 I 9.00 2.13 I 45 2-/2x2% 168 ' 229 54 2.0 6.88 1 9.00 2.13 I 4.8 2-/2521/4 175 229 54 J 2.2 8.00 10.00 2.13 I 5.0 203 f453 , 2.3 7.63 10.00 2.13 5.5 2-/252/4 194 254 54 2.5 2-Y2X3 5 1i3.00 2.13 t 5.5 207 254 54 2.5 2- 5/8 x 4¼ 10.50 134 2.63 U .3 267 334 67 5.1 JSL _,'èJSL I iSL akw REP-IF Rated for wet and dry sprinkler systems at 350 psi/2413kPa for 1¼ -4/32 - 100 mm sizes and 300 psi /2068kPa for 41/4 - 81108 - 200mm sizes; Schedule 10 roll grooved or Schedule 40 cut or roll grooved steel pipe. Style 005 is rigid and does not accommodate expansion, contraction or angular deflection. 1 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for perfor- mance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. t The allowable pipe separation dimension shown is for system layout purposes only. Style 005 couplings are con- sidered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. § Style 005 couplings are VdS and _PC Approved to 12 Bar/175 psi. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. 1fltV) ) \ Ac- tauIi Ce DtI I JPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS I U.0 FireLock® Rigid Coupling STYLE 005 0 WITH VIC-PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel (North America); red enamel (Europe) Optional: Hot dipped galvanized Gasket: Grade "E" EPDM - Type A Vic-PIus°' Gasket System (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Vic-Plus° Gasket System, requiring no field lubrication for most installation conditions. Grade "L" Silicone Recommended for dry heat, air without hydrocarbons to +350°F and certain chemical services. For dry services, Victaulic continues to recommend the use of Grade "E" Type A FlushSeal® Gasket. Contact Victaulic for details. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. A Standard gasket and FlushSeal gasket approved for dry pipe systems to —40°F/-40°C. Based on "typical" pipe surface conditions, supplemental lubricant is recommended for services installed below 0°F/-18°C and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water. Supplemental lubrication may also be required on pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams. Victaulic continues to recommend the use of FlushSeal gaskets for dry services. www.victaulic.com 1~-t Aic—taul—he VIcTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAUUC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. S FireLock® Rigid Coupling STYLE 005 WITH VIC-PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) S GENERAL NOTES WARNING: Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. S III lIIIIIIIIIlIIIIIIIlIIIIlIIIIIIIlIIIIlII S WCAS-697KR4 For complete contact information, visit www.victaulic.com 10.02 1538 REV I UPDATED 9/2006 Ac—taulic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED, PRINTED IN THE USA. in IV) Hole Cut Piping System FireLock Outlet-T . TYLE 922 For Complete Information Ui Request Publication 10.52 U) C-, -J 0 M Ak Z 0 F-U Ui U, Incorporates 1/2-1710-25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products UL/ULC Listed, LPCB, VdS/FM Approved for branch connections on wet and dry systems Style 922 FireLock Outlet-Ts are not approved for cross configurations Pressure rated up to 300 psi/2065 kPa and rated up to 230 psi/16 Bar at the ambient temperatures typical for fire protection systems Sizes from 1¼x½"/32x 15 mm through 21/2 x 1/76.1 x 25 mm 1 ¼ ½ 1 3A6 1.30 1.83 1.10 3.87 2,56 1.0 32 15 30.2 33.0 46.5 i 27.9 98.3 65.0 0.45 -- .t .--- + --------------t -- t ~ 1 3A6 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 1 46.5 1 27.9 98.3 65.0 0.50 - --.. --- --. - --, -- - . 1 1 3A6 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 1½ 1/2 1 3A6 1.42 1.95 1.22 4.08 2.56 1.2 40 15 30.2 36.1 I 49.5 31.0 103.6 65.0 0.54 H --+ ---- - 3/4 1 3A6 1.40 1.95 1,22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 . 0.54 -- -4 - t'- - 1 1 3A6 1,64 2.30 1.22 4.08 I 2.56 1.3 25 - 30.2 41.7 58,4 31.0 103.6 65.0 0.59 2 1/2 1/ 1 1.66 1 2.19 1,46 4,60 2.56 ' 1.3 50 15 30.2 42.2 55.6 37,1 116.8 65.0 ' 0.59 - -+ 3/~ 1 1.64 2.19 1.46 4.60 , 2.56 1.4 20 30.2j 41.7 55.6 , 37.1 116.8 - 65.O ,j 0.64 1 1 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 - 47.8 , - 64.5 , 37.1 1 116.8 65.0 0.68 2½ ½ - 1/16 1.91 2,44 1.71 5,40 I 2.56 1.6 65 X 15 30.2 48.5 62.0 434 137,2 65.0 0.73 -- ~ 13/16 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 I 137.2 ' 65.0 0.73 + --- + - -- 1 1/6 2.13 2.79 1.71 I 5.40 2.56 1.6 25 , 302 , - 541 - 709 , 43.4 I 137.2 65.0 0.73 761 ½ 1 3A6 1.91 2.44 1.71 5.50 2.56 1.6 . mm 15 300 48.5 62.0 434 9.7 l_L0 3/4 1 3A6 1.89 2.44 1.71 I 5.50 2.56 1.6 20 30.2 480 620 - 44 139.7 65.0 0.73 1 1 3/16 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 i 65.0 ' 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pendent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NFl threads (dimensions are approximate). y 4 z- 4~- r-F Ll 61 V TYPICAL FOR ALL SIZES 5-9 'AC- tElU1iC WWW.VICTAULIC.COM G-105 FIRE PROTECTION CATALOG c®US LISTED S Pipe Clamps Fig. 24 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe** OTOLIca Double Fastener Strap Side Mounted (B-Line B3183) ~@'.S I* Size Range: 3/4" (20mm) thru 2" (50mm) CPVC pipe LISTED Material: Pie-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom - - -. of a beam. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.912mm) steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of - NFPA 13, 13R and 13D. / Features: Fig. 24 incorporates features which protect the pipe and -L ease installation. The flared edge design protects the CPVC pipe from I any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the ) product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pie-drilling of a pilot hole in wood is required. Finish: Pre-Galvanized Order By: Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. ** With reduced spacing, consult factory. CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size Wt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) R. (ml in. (mm) Lbs. (kg) 24-/4 3/4" (20) 2/1" (58.7) 1/32" (27.8) 1/16" (30.2) 51/2 (1.67) /i" (7.9) 9 (4.1) 24-1 1" (25) 2/8" (66.7) 1/16" (33.3) 1/16" (30.2) 6 (1.83) /16" (7.9) 9 (4.1) 24_11/4 11/4" 1321 3" (76.2) 11/2" (38.1) 1/16" (30.2) 61/2 (1.98) /16" (7.9) 11 (5.0) 24_11/2 11/2 (40) 31/4" (82.5) i/" (42.3) 1/16" (30.2) 7 (2.13) /16" (7.9) 12 (5.4) 24-2 2" (50) 311/16' (93.7) 127/32" (43.6) 1/1" (30.2) 8 (2.44) /16" (7.9) 15 16.81 Fig. 25 - Surge Restrainer Size Range: - One size fits 3/4" (20mm) thru 2" (40mm) pipe. Material: - Pie-Galvanized Steel Function: - Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUL). Finish: Pre-Galvanized Order By: Figure number and band hanger, size from 3/4" (20mm) thru 2" (40mm). Patent #5,344,108 B-Line by Et.N All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 38 Fire Protection Solutions All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 13 B-Line by t.N Beam Clamps Fig. 65 - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening Fig. 65XT - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening (bottom of page) C&S W Size Range: umb Fig. 65 - 1/2'..13 rod sizes, and /'-11 rod sizes Fig. 65XT - /8'-16 rod size (see below) Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (19.0mm). Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, /8'-16 rod will support 1/2" (15mm) thru 4" (100mm) pipe /2'-13 rod will support thru 8" (200mm) pipe Finish: Plain. Contact B-Line for alternative finishes and materials. Set Screw and Locknut Included Order By: Figure number and finish Fig. 65 Patent #4,570,885 Part Rod Size B C D E No. A in. (mm) in. (mm) in. (mm) in. (mm) 65-1/2 1/2"_13 11/2" (38.1) 3/4" (19.0) 1" (25.4) /16" (14.3) 65-I8 /811-11 11/2" (38.1) 3/4" (19.0) 1" (25.4) /i" (14.3) - Part F Approx. WtJ100 - - - - - No. in. (mm) Lbs. (kg) 65-1/2 11/4" (31.7) 55 (24.9) 65-/ 11/4" (31.7) 55 (24.9) - Fig. 65XT-3/8 - Beam Clamp Feature: Extruded holes allows for more thread engagement of threaded rod and set screw. Weight: Approx. Wt./100 - 28.0 Lbs. (12.7kg) Finish: Plain or Electro-Galvanized Order By: Figure number and finish Approvals: Underwriters Laboratories Listed (cULus) and FM Approved (FM) for up to 4" (100mm) pipe. Designed to meet or exceed requirements of FM DS 2-0. C (DUS USTED S Set Screw and Locknut Included 1/o" (34.91 S Beam Clamps Fig. 69R - Retrofit Capable Beam Clamp Retaining Strap Size Range: /8'-16 & 1/2'.13 rod 4" (101,6mm) thru 16" (406.4mm) lengths Note: longer lengths are available consult factory Material: Pre-Galvanized Steel Function: To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13. Features: Beveled locking slot* is precisely formed to align with the threaded section of a hanger rod or set screw and engage the unit securely. May be used as shown in Section "A-A" or inverted. Allows easy installation for new construction or retrofit applications. Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore the beveled locking slot of the Fig. 69R will provide a secure reliable installation. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Finish: Pre-Galvanized Order By: Figure number, length, and finish. Note: Minimum return on strap is 1" (25.4mm) For Use With: Any B-Line or TOLCO beam clamp. * Patent #5,947,424 Slot Width Length Part No. in. (mm) 6911-3/8-11. /16" (30.1) Specify 69R-'/2-L /16" (30.1) Specify ®TOLCQ Component of State of California OSHPD Approved C&S Seismic Restraints System lISTED A-A [1 S All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 17 B-Line by E%.N A Thread Size Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) ®ToLco *Size B32051 - Threaded Rod (right & left hand threads) Range: I8"-16 thru 3-4 rod Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature: 750°F (399°C) Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Part No. Thread Size A Standard Thread Length TI in. (mm) 650°F (343°C) Lbs. (kN) Design Load 750°F (399°C) Lbs. (kN) B3205-318 x 1 /8"-16 21/2' (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x •1 1/2 _13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x L /8'-11 212' (63.5) 2160 (9.61) 1692 (7.52) B3205-314 x I /4"-10 3 (76.2) 3230 (14.37) 2530 (11.25) B3205-7/8 x 'I' /8"-9 31/2' (88.9) 4480 (19.93) 3508 (15.60) W For larger sizes consult full line pipe hanger catalog. ATR - All Threaded Rod (TOLCO Fig. 99 & Fig. 100) Size Range: /8'-16 thru 11/2'6 rod in 10' (3.05m) lengths Material: Steel Maximum Temperature: 750°F 1399°C) Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Note: Fig. 99 is cut to length all threaded rod. Fig. 100 is full length. Part No. Threads Recommended load Approx. Wt.1100 Ft. & Size Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4" x '1' 20 240 (1.07) 12 (5.44) ATR 3/8" x L' 16 730 (3.24) 29 (13.15) ATR /2" x '1 13 1350 (6.00) 53 (24.04) ATR /8' x'1' 11 2160 (9.60) 89 (40.37) ATR 3/4" x 1' 10 3230 (14.37) 123 (55.79) S ATR 1/8" x 1' 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog. B-Line by E1.N All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 94 Fire Protection Solutions Fig. 200.21/210 200-8 Fig. 200 Fig. 200S Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B3110NF) Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B3170NFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut ®TOLcO c®.USTED Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design - - keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in ,( - hanger before installation. Adjusting nut is easily removed. / Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Fig. 200-1 to 200-2 Conforms to Federal Specifications WW-H-1 71 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of Fig. 200C Fig. 200F Pipe Size Rod Size A B Approx. Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200_1/2 1/2" (15) /8"-16 31/8 (79.4) 2/8 (66.7) 11 (5.0) 200-/4 3/4' (20) /8"-16 31/8' (79.4) 21/2 (63.5) 11 (5.0) 200-1 1° (25) /8"-16 3/8' (85.7) 2/8' (66.7) 12 (5.5) 200-11I4 11/4' (32) /8"-16 33/4" (94.0) 2/8' (73.0) 13 (5.9) 200-11/2 11/2' (40) /8"-16 3/8" (98.4) 2/8' (73.0) 14 (6.4) 200-2 2" (50) /8"-16 41/2" (114.3) 3' (76.3) 15 (6.9) 200_21/2 21/2 (65) /8°-16 5/8" (142.9) 41/8° (104.7) 27 (12.3) 200-3 3" (75) /8'-16 5/8' (149.1) 4' (101.6) 29 (13.3) 200-31/2 31/2° (90) /8'-16 7 /8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) /8°-16 73/8" (187.3) 5' (127.0) 35 (16.0) 200-5 5" (125) 1/2"13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2 .13 101/8" (257.2) 6/4° (171.4) 13 (33.4) 200-8 8" (200) 1/2 .13 131/8" (333.4) 8/4° (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 21 by Er.N SAMMYS®FOR WOOD / Not less than Wood Flooring No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drilUdver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. Watch a wdeodemonotra5on a1 www.ifwbuildox.comj a. #14 Black Nut Driver Part #8113910 i . #14 SW Red Nut Driver Part # 8114910 1/4" 8002957 GST 100 1/4x 1 r 1/4' 8003957 GST 200 - 1/4x2" 1760 (Fir) 3/8" 8007957 GST 10 1/4 x1" 300 "> 3/8" 8008957 GST 20 1/4x2 1760 (Fir) 850 3/8" 8068925 GST 20-SS 1/4x2" 1760 (Fir) 850 F 3/8 8009925 GST 25-380 3/8x2 1/2 2113 (Fir) 1500 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) - - - 1500 3/8" 8069925 GST 30-SS 1/4 x3" 2060 (Fir) - 1/2 8013925 GST2 1/4x2" 1760 (Fir) f - 1/2" 8015925 GST3 - 1/4x3 2275 (Fir) 25 125 25 125 25 125 1475 25 125 25 125 25 125 1475 25 125 ?5 125 25 125 25 125 GOP - WNIAC w' TUED USA ' SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. ON , MI TEN Not less than 2" nominal width (1-1/2") up to 3-1/2" pipe; not less than 3" (2-1/2) nominal width 4" & 5" pipe 4 A 4, Minimum 2-1/2" from bottom for branch lines. Minimum 3" from bot- tom for main lines. Exception: This requirement shall not apply to 2" or thicker nailing ships resting on top of steel beams. No pre-drilling required. IN Quick to install using the Sammy Floor Joist Driver with an 18V cordless ________ drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. C-Wave a video demorstation at www.itwbuildex.com w HORIZONTAL MOUNT E" 1/4 8019957 SWG200 1/4x2" 1725 (Fir) 25 125 I [ . 3/8 -- 8020957 SWG 10 114x1 622 (Fir) 300 25 125 I a 3/8 8021957 SWG20 - 1/4x2 1725 (Fir) 1050 25 125 - 3/8 8073925 SWG2O-SS 1/4x2 - 1725 (Fir) 850 25 125 I 3/8..8022925 SWG25-380 3/8x2-1/2" 2249 (Fir) 1500 25 125 #14SWRed LL .__. 25 - SWG3O - 1/4x3" - 1884 (Fir) . -- 25 125 Nut Driver Part # 8114910 * May require pre-drilling; consult joist manufacturer Eliminates distortion of threaded rod. Accommodates up to 3 1/* x 12 pitch roof. Allows 17° deflection from vertical. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. #14 Black Nut Driver - 4L€° 3/6" 8139957 SH-GST2O 1/4x2 1257 (Fir) 1050 1475 25 125 Part# 8113910 1903 Dim. Lumber . 8269957 SH-GST/CST2O 5/16x 1-3/4" 1500 1406@45°off vertical 25 125 350@45° Dim. Lumber - - 903 Dim. Lumber 1/2 8303957 SH-GST/CST 2.0 5/16 x 1-3/4 1406 @ 45°ofi vertical 25 125 Dim. Lumber May require pre-drilling; consult joist manufacturer. #14SHOrange - Nut Driver Part # 8273910 SAFETY DATA SHEET A CITGO HyDuranceTM AW Fluid 32 CITGO. w Section 1. Identification GHS product identifier : CITGO HyDuranceTm AW Fluid 32 Synonyms : Hydraulic Fluid Material uses : Lubricating oil Code : 633607001 Supplier's details : CITGO Petroleum Corporation P.O. Box 4689 Houston, TX 77210 sdsvendcitgo.com Emergency telephone : Technical Contact: (800) 248-4684 number (with hours of Medical Emergency: (832) 486-4700 operation) CH EMTREC Emergency: (800) 424-9300 (United States Only) Section 2. Hazards identification OSHAIHCS status : While this material is not considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200), this SOS contains valuable information critical to the safe handling and proper use of the product. This SOS should be retained and available for employees and other users of this product. Classification of the : Not classified. substance or mixture GHS label elements Signal word : Warning Hazard statements : Injection of pressurized hydrocarbons can cause severe permanent tissue damage. Initial symptoms may be minor. Precautionary statements General : Avoid contact with eyes, skin and clothing. Thoroughly wash exposed areas and clothing with soap and water. IF IN EYES: Rinse cautiously with water for several minutes. IF SWALLOWED: Do not induce vomiting. If you feel unwell, seek medical attention and show the label when possible. Keep out of reach of children. Prevention : Not applicable. Response Not applicable. Storage : Not applicable. Disposal : Not applicable. Hazards not otherwise : Injection of petroleum hydrocarbons requires immediate medical attention. classified Section 3. Composition/information on ingredients Substance/mixture Mixture Other means of Hydraulic Fluid identification CAS number/other identifiers CAS number : Not applicable. Date of issue/Date of revision :4/18/2018 Date of previous issue :1111712017 Version :3 1/10 CITGO HyDuranceTM AW Fluid 32 Section 3. Composition/information on ingredients Ingredient name % CAS number Distillates (petroleum), hydrotreated heavy paraffinic Residual oils (petroleum), solvent-dewaxed ~t90 55 64742-54-7 64742-62-7 Any concentration shown as a range is to protect confidentiality or is due to process variation. There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section. Occupational exposure limits, if available, are listed in Section 8. Section 4. First aid measures Description of necessary first aid measures Eye contact : Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs. Inhalation : Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical attention if symptoms occur. Skin contact : Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur. Ingestion : Wash out mouth with water. Remove victim to fresh air and keep at rest in a position comfortable for breathing. Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur. Most important symotoms/effects, acute and delayed Potential acute health effects Eye contact : No known significant effects or critical hazards. Inhalation No known significant effects or critical hazards. Skin contact : Injection of pressurized hydrocarbons can cause severe permanent tissue damage. Initial symptoms may be minor. Ingestion : No known significant effects or critical hazards. Over-exposure signs/symptoms Eye contact : No specific data. Inhalation : No specific data. Skin contact No specific data. Ingestion No specific data. Indication of immediate medical attention and special treatment needed. if necessa Notes to physician : In the event of injection in underlying tissue, immediate treatment should include extensive incision, debridement and saline irrigation. Inadequate treatment can result in ischemia and gangrene. Early symptoms may be minimal. Specific treatments : Treat symptomatically and supportively. Protection of first-aiders : No action shall be taken involving any personal risk or without suitable training. See toxicological information (Section 11) Section 5. Fire-fighting measures Extinuuishing media Suitable extinguishing Use an extinguishing agent suitable for the surrounding fire. media Unsuitable extinguishing None known. media Date of issue/Date of revision :4/18/2018 Date of previous issue :1111712017 Version :3 2110 S S CITGO HyDuranceTM AW Fluid 32 Section 5. Fire-fighting measures S Specific hazards arising from the chemical Hazardous thermal decomposition products Special protective actions for fire-fighters Special protective equipment for fire-fighters In a fire or if heated, a pressure increase will occur and the container may burst. Decomposition products may include the following materials: carbon dioxide carbon monoxide Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Section 6. Accidental release measures Personal precautions, protective eciuipment and emergency procedures For non-emergency : No action shall be taken involving any personal risk or without suitable training. personnel Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Put on appropriate personal protective equipment. For emergency responders : If specialized clothing is required to deal with the spillage, take note of any information in Section 8 on suitable and unsuitable materials. See also the information in "For non- emergency personnel". Environmental precautions : Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air). 0 Methods and materials for containment and cleaning up Small spill Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor. Large spill : Stop leak if without risk. Move containers from spill area. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see Section 13). Dispose of via a licensed waste disposal contractor. Note: see Section 1 for emergency contact information and Section 13 for waste disposal. Section 7. Handling and storage Precautions for safe handling Protective measures : Put on appropriate personal protective equipment (see Section 8). Advice on general : Eating, drinking and smoking should be prohibited in areas where this material is occupational hygiene handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures. Conditions for safe storage, : Store in accordance with local regulations. Store in original container protected from including any direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials incompatibilities (see Section 10) and food and drink. Keep container tightly closed and sealed until ' ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers. Use appropriate containment to avoid environmental contamination. See Section 10 for incompatible materials before handling or use. Date of issue/Date of revision 4/18/2018 Date of previous issue :11/17/2017 Version :3 3110 CITGO HyDurance"'A W Fluid 32 Section 7. Handling and storage Bulk Storage Conditions: Maintain all storage tanks in accordance with applicable regulations. Use necessary controls to monitor tank inventories. Inspect all storage tanks on a periodic basis. Test tanks and associated piping for tightness. Maintain the automatic leak detection devices to assure proper working condition. Section 8. Exposure controls/personal protection Control parameters Occupational exposure limits Ingredient name Exposure limits Distillates (petroleum), hydrotreated heavy paraffinic ACGIH TLV (United States, 3/2016). TWA: 5 mg/ml 8 hours. Form: Inhalable fraction OSHA PEL (United States, 6/2016). TWA: 5 mg/ml 8 hours. NIOSH REL (United States, 10/2013). TWA: 5 Mg/M3 10 hours. Form: Mist STEL: 10 mg/m3 15 minutes. Form: Mist Residual oils (petroleum), solvent-dewaxed ACGIH TLV (United States, 6/2013). TWA: 5 mg/m3 8 hours. Form: Inhalable fraction NIOSH REL (United States, 4/2013). TWA: 5 mg/m3 10 hours. Form: Mist STEL: 10 mg/m3 15 minutes. Form: Mist OSHA PEL (United States, 2/2013). TWA: 5 mg/m3 8 hours. Appropriate engineering : Good general ventilation should be sufficient to control worker exposure to airborne S controls contaminants. Environmental exposure : Emissions from ventilation or work process equipment should be checked to ensure controls they comply with the requirements of environmental protection legislation. In some cases, vapor controls, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels. Individual Drotection measures Hygiene measures : Wash hands, forearms and face thoroughly after handling chemical products, before eating, smoking and using the lavatory and at the end of the working period. Appropriate techniques should be used to remove potentially contaminated clothing. Wash contaminated clothing before reusing. Ensure that eyewash stations and safety showers are close to the workstation location. Eye/face protection : Safety glasses equipped with side shields are recommended as minimum protection in industrial settings. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: chemical splash goggles. Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If inhalation hazards exist, a full-face respirator may be required instead. Skin orotection Hand protection : Chemical-resistant gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Body protection : Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Other skin protection Avoid skin contact with liquid. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Leather boots are not protective for liquid contact. [I Date of issue/Date of revision :411812018 Date of previous issue :1111712017 Version :3 4110 C!TGO HyDurancelm AW Fluid 32 Section 8. Exposure controls/personal protection S Respiratory protection : Avoid inhalation of gases, vapors, mists or dusts. Use a properly fitted, air-purifying or supplied-air respirator complying with an approved standard if a risk assessment indicates this is necessary. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. Section 9. Physical and chemical properties Appearance Physical state Color Odor pH Boiling point Flash point Lower and upper explosive (flammable) limits Vapor pressure Vapor density Relative density Density lbs/gal Density gm/cm' Gravity, °APl Flow time (ISO 2431) Viscosity Viscosity SUS Liquid. Light amber [Light] Mild petroleum odor [Slight] Not applicable. Not available. Open cup: 214°C (417.2°F) [Cleveland.] Not available. Not available. Not available. Not available. 7.14 lbs/gal 0.86 g/cm3 33.6 Not available. Dynamic (room temperature): Not applicable. Kinematic (room temperature): Not applicable. Kinematic (40°C (1040F)): 0.32 cm2/s (32 cSt) 155 SUS @100F Section 10. Stability and reactivity Reactivity : Not expected to be Explosive, Self-Reactive, Self-Heating, or an Organic Peroxide under US GHS Definition(s). Chemical stability : The product is stable. Possibility of hazardous : Under normal conditions of storage and use, hazardous reactions will not occur. reactions Conditions to avoid : No specific data. Incompatible materials : No specific data. Hazardous decomposition : Under normal conditions of storage and use, hazardous decomposition products should products not be produced. Section 11. Toxicological information Information on toxicological effects Acute toxicity Product/ingredient name Result Species Dose Exposure Distillates (petroleum), hydrotreated heavy paraffinic LD50 Oral Rat >5000 mg/kg Conclusion/Summary Date of issue/Date of revision :411812018 Date of previous issue :1111712017 Version :3 5110 CITGO HyDurance AW Fluid 32 Section 11. Toxicological information Distillates (petroleum), hydrotreated heavy paraffinic: Mineral oil mists derived from highly refined oils are reported to have low acute and sub-acute toxicities in animals. Effects from single and short-term repeated exposures to high concentrations of mineral oil mists well above applicable workplace exposure levels include lung inflammatory reaction, lipoid granuloma formation and lipoid pneumonia. In acute and sub-acute studies involving exposures to lower concentrations of mineral oil mists at or near current work place exposure levels produced no significant toxicological effects. Irritation/Corrosion Not available. Skin : No additional information. Eyes : No additional information. Respiratory : No additional information. Sensitization Not available. Skin : No additional information. Respiratory : No additional information. Mutagenicitv Not available. Conclusion/Summary : No additional information. Carcinogen icily Not available. Conclusion/Summary : No additional information. Renroductive toxicity Not available. Conclusion/Summary : No additional information. Teratogenicity Not available. Conclusion/Summary : No additional information. Specific target organ toxicity (single exposure) Not available. Specific target organ toxicity (repeated exposure) Not available. Aspiration hazard Not available. Information on the likely : Not available. routes of exposure Potential acute health effects Eye contact : No known significant effects or critical hazards. Inhalation : No known significant effects or critical hazards. Skin contact : Injection of pressurized hydrocarbons can cause severe permanent tissue damage. Initial symptoms may be minor. Ingestion No known significant effects or critical hazards. is Svmntoms related to the nhysical, chemical and toxicological characteristics Eye contact : No specific data. Inhalation : No specific data. Date of issue/Date of revision 4/16/2018 Date of previous issue :1111712017 Version :3 6110 C!TGO HyDuranceTM A W Fluid 32 Section 11. Toxicological information S Skin contact Ingestion No specific data. No specific data. Delayed and immediate effects and also chronic effects from short and long term exposure Short term exposure Potential immediate : Not available. effects Potential delayed effects : Not available. Lone term exposure Potential immediate : Not available. effects Potential delayed effects : Not available. Potential chronic health effects Not available. General Carcinogenicity M utagenicity Teratogenicity Developmental effects Fertility effects No known significant effects or critical hazards. No known significant effects or critical hazards. No known significant effects or critical hazards. No known significant effects or critical hazards. No known significant effects or critical hazards. No known significant effects or critical hazards. Section 12. Ecological information Toxicity Not available. Conclusion/Summary : Not available. Persistence and degradability Not available. Conclusion/Summary : Not available. Bioaccumulative potential Not available. Mobility in soil Soil/water partition : Not available. coefficient (Koc) Other adverse effects No known significant effects or critical hazards. Section 13. Disposal considerations Disposal methods The generation of waste should be avoided or minimized wherever possible. Disposal S of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction. Waste packaging should be recycled. Incineration or landfill should only be considered when recycling is not feasible. This material and its container must be disposed of in a Date of issue/Date of revision :411812018 Date of previous issue :1111712017 Version :3 7/10 CITGO HyDuranceTM AW Fluid 32 Section 13. Disposal considerations safe way. Empty containers or liners may retain some product residues. Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers. Section 14. Transport information_______________ DOT Classification IMDG IATA UN number Not regulated. Not regulated. Not regulated. UN proper shipping name - - - Transport hazard class(es) - - - Packing group - - - Environmental hazards No. No. No. Oil: The product(s) represented by this SIDS is (are) regulated as "oil" under 49 CFR Part 130. Shipments by rail or highway in packaging having a capacity of 3500 gallons or more or in a quantity greater 42,000 gallons are subject to these requirements. In addition, mixtures containing 10% or more of this product may be subject to these requirements. Special precautions for user : Transport within user's premises: always transport in closed containers that are C upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage. Transport in bulk according : Not available. to Annex II of MARPOL and the IBC Code Section 15. Regulatory information U.S. Federal regulations : United States inventory (TSCA 8b): All components are listed or exempted. Clean Water Act (CWA) 307: Phosphorodithioic acid, O,O-di-C1 -1 4-alkyl esters, zinc salts; toluene; phenol Clean Water Act (CWA) 311: toluene; phenol This material is classified as an oil under Section 311 of the clean Water Act (CWA) and the Oil Pollution Act of 1990 (OPA). Discharges or spills which produce a visible sheen on waters of the United States, their adjoining shorelines, or into conduits leading to surface waters must be reported to the EPA's National Response Center at (800) 424-8802. SARA 302/304 Composition/information on ingredients Name EHS SARA 302 TPQ SARA 304 RQ (lbs) (gallons) (Ibs) (gallons) Phenol <0.001 Yes. 500/10000 - 1000 - SARA 304 RQ : 106837606.8 lbs / 48504273.5 kg [14899387.7 gal /56400318 L] SARA 311/312 Classification Not applicable. Date of issue/Date of revision :411812018 Date of previous issue :1111712017 Version :3 8110 CITGO HyDuranceTM AW Fluid 32 Section 15. Regulatory information Composition/information on ingredients No products were found. State reaulations Massachusetts : None of the components are listed. New York : None of the components are listed. New Jersey : None of the components are listed. Pennsylvania : None of the components are listed. California Prop. 65 Clear and Reasonable Warnings (2018) Li\ WARNING: This product can expose you to chemicals including Ethyl acrylate, which is known to the State of California to cause cancer, and Toluene, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov. Ingredient name % Cancer Reproductive No significant risk Maximum level acceptable dosage level toluene <0.01 No. Yes. - Yes. ethyl acrylate <0.001 Yes. No. - - International regulations WHMIS (Canada) Inventory list United States Australia .Canada China Europe Japan Malaysia New Zealand Philippines Republic of Korea Taiwan Thailand Turkey Viet Nam Not controlled under WHMIS (Canada). All components are listed or exempted. All components are listed or exempted. All components are listed or exempted. All components are listed or exempted. All components are listed or exempted. Japan inventory (ENCS): Not determined. Japan inventory (ISHL): Not determined. Not determined. All components are listed or exempted. All components are listed or exempted. All components are listed or exempted. Not determined. Not determined. Not determined. Not determined. Section 16. Other information National Fire Protection Association (U.S.A. Flammability Health 4 1 0 0 Instability/Reactivity Special Reprinted with permission from NFPA 704-2001, Identification of the Hazards of Materials for Emergency Response Copyright ©1997, National Fire Protection Association, Quincy, MA 02269. This reprinted material is .not the complete and official position of the National Fire Protection Association, on the referenced subject which is represented only by the standard in its entirety. Date of issue/Date of revision : 411812018 Date of previous issue :1111712017 Version :3 9110 CITGO HyDuranceTM AW Fluid 32 Section 16. Other information Copyright ©2001, National Fire Protection Association, Quincy, MA 02269. This warning system is intended to / be interpreted and applied only by properly trained individuals to identify fire, health and reactivity hazards of \. chemicals. The user is referred to certain limited number of chemicals with recommended classifications in NFPA 49 and NFPA 325, which would be used as a guideline only. Whether the chemicals are classified by NFPA or not, anyone using the 704 systems to classify chemicals does so at their own risk. Procedure used to derive the classification Classification Justification Not classified. History Date of printing 5/1/2018 Date of issue/Date of : 4/18/2018 revision Date of previous issue : 11/17/2017 Version : 3 Key to abbreviations : ATE = Acute Toxicity Estimate BCF = Bioconcentration Factor GHS = Globally Harmonized System of Classification and Labelling of Chemicals IATA = International Air Transport Association IBC = Intermediate Bulk Container IMDG = International Maritime Dangerous Goods LogPow = logarithm of the octanol/water partition coefficient MARPOL = International Convention for the Prevention of Pollution From Ships, 1973 as modified by the Protocol of 1978. (Marpol" = marine pollution) UN = United Nations References : Not available. V Indicates information that has changed from previously issued version. Notice to reader THE INFORMATION IN THIS SAFETY DATA SHEET (SDS) WAS OBTAINED FROM SOURCES WHICH WE BELIEVE ARE RELIABLE. HOWEVER, THE INFORMATION IS PROVIDED WITHOUT ANY WARRANTY, EXPRESSED OR IMPLIED REGARDING ITS CORRECTNESS OR ACCURACY. SOME INFORMATION PRESENTED AND CONCLUSIONS DRAWN HEREIN ARE FROM SOURCES OTHER THAN DIRECT TEST DATA ON THE SUBSTANCE ITSELF. THIS SDS WAS PREPARED AND IS TO BE USED ONLY FOR THIS PRODUCT. IF THE PRODUCT IS USED AS A COMPONENT IN ANOTHER PRODUCT, THIS SDS INFORMATION MAY NOT BE APPLICABLE. USERS SHOULD MAKE THEIR OWN INVESTIGATIONS TO DETERMINE THE SUITABILITY OF THE INFORMATION OR PRODUCTS FOR THEIR PARTICULAR PURPOSE OR APPLICATION. THE CONDITIONS OR METHODS OF HANDLING, STORAGE, USE, AND/OR DISPOSAL OF THE PRODUCT ARE BEYOND OUR CONTROL AND MAY BE BEYOND OUR KNOWLEDGE. FOR THIS AND OTHER REASONS, WE DO NOT ASSUME RESPONSIBILITY AND EXPRESSLY DISCLAIM LIABILITY FOR ANY LOSS, DAMAGE OR EXPENSE ARISING OUT OF OR IN ANY WAY CONNECTED WITH HANDLING, STORAGE, USE OR DISPOSAL OF THE PRODUCT. CITGO is a registered trademark of CITGO Petroleum Corporation Date of issue/Date of revision :411812018 Date of previous issue :1111712017 Version :3 10/10