Loading...
HomeMy WebLinkAbout5940 DARWIN CT; ; FPC2020-0142; PermitPERMIT REPORT 4L(7city of Carlsbad Print Date: 06/10/2021 Permit No: FPC2020-0142 Job Address: 5940 DARWIN CT, CARLSBAD, CA 92008-7395 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2121201700 Track U: Applied: 08/18/2020 Valuation: $813,227.35 Lot U: Issued: 09/01/2020 Occupancy Group: Project U: Finaled Close Out: 06/10/2021 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: Description: PRATT & WHITNEY PHASE 2 -SPRINKLER TI (101 HEADS) Applicant: FPContractor: COSCO FIRE PROTECTION COSCO FIRE PROTECTION INC MICHAEL LOVELY 1075 W LAMBERT RD 4990 GREENCRAIG LN BREA, CA 92821-2944 SAN DIEGO, CA 92123-1673. (858) 444-2000 (858) 444-2000 x1727 FEE AMOUNT FIRE NFPA 13 or 13R System> 100 heads $654.00 Total Fees: $654.00 Total Payments To Date: $654.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov .16I96S. cosco 00 I Fire Protection San Diego Branch Office 4990 Greencraig Lane San Diego, CA 92123 (858) 444-2000 fax: 444-2056 CA Lic.: C-16 #577621 www.coscofire.com MATERIAL SUBMITTAL & CALCULATIONS Date: 08/13/2020 Pratt & Whitney 0 5940 Darwin Ct. Carlsbad, CA 920,08 JOB # 10.CA_5501 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted by: M.J. Los Angeles • San Francisco • Orange • Fresno • San Diego • Seattle Victaulic® FireLock NXTTM Preaction Trim /tauIiC Series 769N 31.82 Patented 1.0 PRODUCT DESCRIPTION Available Sizes 11/2 -87DN40—DN200 Pressure Class Up to 300 psi/2068 kPa/21 bar Minimum Air Pressure 13 psi/90 kPa/.90 bar Acutation Options Series 776 Low Pressure Actuator Series 767 Electric/Pneumatic Actuator Series 798 Double-Pneumatic Actuator Electric Release 24V DC Normally closed solenoid Release Mechanism Non-Interlocked Single Interlocked Double Interlocked Valve Configurations Bare Pre-trimmed Vic-Quick Riser: Pre-trimmed and includes: Shut Off Valve (1 1/2JDN40: Series 728 Ball Valve, 2 - 87DN50 - DN200: Series 705 FireLock Butterfly Valve) Pre-set alarm pressure switch Pre-set high or low air pressure switch (Dry Pilot Only) Drain Connection kit Fire-Pac Series 745 (refer to Victaulic publication 30.23) ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph L Submitted By Date Approved Date victaulic.com 31.82 9999 Rev B updated 02/2019 © 2019 Victaulic company. All rights reserved. #tauIic 1 victaulic.com 1.0 PRODUCT DESCRIPTION (Continued) Application: For use on fire protection systems only 2.0 CERTIFICATION/LISTINGS 104-la/02 3.0 SPECIFICATIONS - MATERIAL Body: Ductile iron conforming to ASTM A536, Grade 65-45-12. Clapper: Aluminum bronze Latch: Aluminum bronze Shafts: Stainless 17-4 Clapper Seal: Peroxide cured EPDM Bushings/Seat 0-rings: Nitrile Springs: Stainless steel Diaphragm: Peroxide cured EPDM with fabric reinforcement ~7- The 1W/DN40 and 2/DNSO valve sizes contain washers under the heads of the cover plate bolts. S Item Description 1 Valve Body 2 clapper 3 Clapper Seal 4 Seal Ring 5 Seal Washer 6 Seal Retaining Ring 7 Seal Assembly Bolt 8 Clapper Spring 9 Clapper Shaft 10 Clapper Shaft Bushing and 0-Ring (Qty. 2) Item Description 11 Cover Plate 12 Cover Plate Gasket 13 Cover Plate Bolts 14 Latch 15 Latch Spring 16 Latch Spring Bushing and 0-Ring (Qty. 2) 17 Diaphragm 18 Diaphragm Cover 19 Diaphragm Cover Cap Screws (Qty. 8) 20 Latch Shaft 31.82 9999 Rev B updated 02/2019 © 2019 Victaulic Company. All rights reserved. victaulic.corn 2 \JtaUIiC victaulic.com 3.0 SPECIFICATIONS - MATERIAL (Continued) 0 Standard Trim Package: Non-Interlocked Pneumatic Release: The pneumatic release system uses a supervisory pilot line to detect a release event. When EITHER a pilot sprinkler or a system sprinkler operates, the water in the diaphragm chamber is released and the valve operates. Pneumatic/Electric Release: The Victaulic Electric Release System uses an electric solenoid valve, approved electric panel and a compatible detection system. The valve operates when the water in the diaphragm chamber is released when Either an electric detection or a system sprinkler operates. Single Interlocked Electric Release: The Victaulic Electric Release System uses an electric solenoid valve, approved electric panel and a compatible detection system. The valve operates when the water in the diaphragm chamber is released when a release system event occurs. Pneumatic Release: The pneumatic release system uses a supervisory pilot line to detect a release event. Only when a pilot sprinkler operates will the water in the diaphragm chamber be released and the valve operate. Double Interlocked Electric Release: The electric/pneumatic/electric release uses two electric detection devices, a fire detection device and a low pressure switch installed in the sprinkler system. The valve will actuate ONLY when BOTH a fire detection event and loss of system pressure occurs. Pneumatic/Electric Release: The pneumatic/electric preaction system uses both a pneumatically pressurized sprinkler system, and an electric release system, (composed of an approved solenoid valve, electric panel and an appropriate sensor). The valve will activate ONLY when there is a pressure loss in the sprinkler system AND the electric detection of a release event. Pneumatic/Pneumatic: The pneumatic/pneumatic system uses one Series 798 Double Pneumatic Actuator to control the Series 769N Actuated Valve. The valve will operate ONLY when there are sprinklers activated in both S the pilot line and the sprinkler system. All required pipe nipples and fittings - standard galvanized finish All standard trim accessories All required gauges Series 755 Manual Release Panel o Optional Trim Package: Black Trim for Foam Systems - If the valve is intended for use in a foam system, black trim must be ordered, per NFPA requirements. Specify this requirement on the order. S 31.82 9999 Rev B updated 02/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 3 4tauIicf victaulic.corn 3.0 SPECIFICATIONS - MATERIAL (Continued) Optional Accessories: El Alarm Pressure Switch - Alarm pressure switches activate electrical alarms at the control panel when the 769N valve actuates and flows water into the system piping. (Note: an open sprinkler may not actuate a 769N valve but any low air alarms should operate.) Air Supervisory Pressure Switch - Air Pressure Supervisory Switches are used to monitor low and high system air pressure and are factory pre-set. El Series 746-LPA Dry Accelerator - The Series 746-LPA Dry Accelerator is required when the Series 769N Preaction trim is installed in large systems to improve response time. Refer to Victaulic publication 30.64. El Series 760 Water Motor Alarm - The Series 760 Water Motor Alarm is a mechanical device that sounds when the 769N valve actuates and is filling the system and discharging any water through any open sprinklers. Refer to Victaulic publication 30.32. Series 75B Supplemental Alarm Device - The Series 75B Supplemental Alarm Device is designed to provide a continuous alarm for systems equipped with a mechanical device. Refer to Victaulic publication 30.33. El Series 75D Water Column Kit - The Series 75D Water Column Kit is designed to minimize residual water in the riser from collecting above the clapper. Refer to Victaulic publication 30.34. El AutoConvert Kit - The AutoConvert Kit includes the Series 776 Low Pressure Actuator, latching solenoid, strainer, 3-in-1 strainer/check/restrictor assembly, air pressure gauge and assembly trim. It is ordered separately and can be installed on any FireLock NXT Single Interlock or Double Interlock Preaction system that includes a solenoid. E] Air Supply System - The air supply system contains all components for establishing and maintaining air in the system. The compressor ball valves, and required trim are included in the air supply system. Air Compressor Refer to Victaulic publication 30.22. Air Maintenance Trim Assembly Refer to Victaulic publication 30.35. El Fire Alarm Control Panels Drain Connection Kit 0 Redundant Electric Solenoid made by alternate manufacturer required by LPCB approval. 31.82 9999 Rev B Updated 02/2019 © 2019 Victaulic company. All rights reserved. viçtaulic.com 4 J$#3taulic vittiilirtnm 4.0 DIMENSIONS A 4JDN 100 valve with single-interlocked pneumatic release preaction trim is shown below 11/2 - 2"/DN40 - DN50 configurations contain 3/4719 mm drain valves 2½ - 30/DN65 - DN80 and 73.0 mm configurations contain 11/4"/31 mm drain valves 4- 80/DN100 - 0N200 configurations contain 20/50mm drain valves Full Open Size Dimensions Weight Each Actual Outside Without With Nominal Diameter A' Al2 B' C D4 D14 E F G H K Trim Trim inches inches inches inches inches inches inches inches inches inches inches inches inches lb lb DIN mm mm mm mm mm mm mm mm mm mm mm mm kg kg 1½ 1.900 9.00 16.37 34.25 9.25 I 16.25 11.00 9.00 3.25 10.25 24.00 6.00 16.7 43.0 DN40 48.3 229 416 870 235 413 279 229 83 260 610 152 7.6 19.5 2 2.375 9.00 13.83 34.25 9.25 17.50 11.00 9.00 3.25 10.25 24.00 6.00 17.0 43.0 DN50 60.3 229 351 870 235 445 279 229 83 260 610 152 7.7 19.5 21/2 2.875 12.61 16.51 35.75 11.25 20.00 12.50 9.50 4.00 9.75 26.00 6.50 41.0 65.0 73.0 320 419 908 286 508 318 241 102 248 660 165 18.7 29.5 3.000 12.61 16.51 35.75 11.25 20.00 12.50 9.50 4.00 9.75 26.00 6.50 41.0 65.0 DN65 76.1 320 419 908 286 508 318 241 102 248 660 165 18.7 29.5 3 3.500 12.61 16.51 35.75 11.25 20.00 12.50 9.50 4.00 9.75 26.00 6.50 41.0 65.0 DN8O 88.9 320 419 908 286 508 318 241 102 248 660 165 18.7 29.5 4 4.500 15.03 19.85 36.50 13.50 22.25 13.50 11.00 4.75 8.50 28.00 8.00 59.0 95.0 DN100 114.3 382 504 927 343 565 343 279 121 216 711 203 26.7 43.0 6.500 16.00 22.13 36.75 14.00 24.50 13.25 11.00 4.50 8.25 28.50 8.25 80.0 116.0 165.1 406 562 933 1 356 622 337 279 114 210 724 210 36.2 52.6 6 6.625 16.00 22.13 36.75 14.00 24.50 13.25 11.00 4.50 8.25 28.50 8.25 80.0 116.0 DN150 168.3 406 562 933 356 622 337 279 114 210 724 210 36.2 52.6 8 8.625 17.50 23.02 39.50 14.75 27.00 13.50 12.25 4.75 8.25 31.25 9.25 122.0 158.0 DN200 219.1 445 585 1003 375 686 343 311 121 210 794 235 55.3 71.6 1 The "A" dimension is the actual takeout dimension of the valve body. 2 The "Al" dimension is the actual takeout dimension of the valve body with water supply main control valve. 3 For systems with the optional Series 746-LPA Dry Accelerator, add 11.50 inches/292 mm to the "B" dimension to account for the additional height. The "0" and "Dl" dimensions are not fixed measurements. The drip cup can be rotated to provide more clearance at the back of the trim. NOTES The drawings shown above reflect the single-interlocked pneumatic release trim with Series 776 Low-Pressure Actuator. In addition, these dimensions can be appliod to all other trim configurations featured within this manual. Components shown as dotted lines denote optional equipment. The recommended drain connection kit (shaded in orange) is for reference and takeout dimensions. This drain connection comes standard when the VQR assembly is ordered. 10 31.82 9999 Rev B updated 02/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 11 JAi -C tauIiC 4.1 DIMENSIONS A 4'JDN 100 valve with electric autoconvert dry release preaction trim is shown below 11/2 - 2'YDN40 - DN50 configurations contain 3/4 /lY mm drain valves 2½ - 3°/DN65 - DN80 and 73.0 mm configurations contain 11/4731 mm drain valves 4- 8"/DN100 - DN200 configurations contain 2'750 mm drain valves Size Dimensions Weight Each Actual Outside Without With Nominal Diameter A' Al2 B' C D Dl E F G H K Trim Trim inches inches inches inches inches inches inches inches inches inches inches inches inches lb lb DN mm mm mm mm mm mm mm mm mm mm mm mm kg kg 11/2 1.900 9.00 16.37 38.00 15.50 25.00 16.25 9.50 3.25 10.25 27.75 6.00 16.7 - 43.0 DN40 48.3 229 416 965 394 635 413 241 1 83 260 1 705 152 7.6 19.5 2 2.375 9.00 13.83 38.00 15.50 25.00 16.25 9.50 3.25 10.25 1 27.75 6.00 17.0 43.0 DN50 1 60.3 229 351 965 394 635 413 241 83 260 705 152 7.7 19.5 21/2 2.875 12.61 16.51 40.75 16.00 24.00 15.00 9.50 4.00 9.75 31.00 6.50 41.0 65.0 73.0 320 419 1035 406 610 381 241 102 248 1 787 165 18.7 29.5 3.000 12.61 16.51 40.75 16.00 24.00 15.00 9.50 4.00 9.75 31.00 6.50 41.0 65.0 DN65 76.1 320 419 1035 406 610 381 241 102 248 787 165 18.7 29.5 3 3.500 12.61 16.51 40.75 16.00 24.00 15.00 9.50 4.00 9.75 31.00 6.50 41.0 65.0 DN80 88.9 320 419 1035 - 406 610 381 241 102 248 787 165 18.7 29.5 4 4.500 15.03 19.85 42.50 15.25 22.50 14.75 11.00 4.75 8.50 34.00 7.50 59.0 95.0 DN100 114.3 382 504 1080 387 572 375 279 121 216 864 191 26.7 43.0 6.500 16.00 22.13 42.50 15.25 26.00 15.25 11.00 4.50 8.25 34.25 8.25 80.0 116.0 165.1 406 562 1080 387 660 387 279 114 210 870 210 36.2 52.6 6 6.625 16.00 22.13 42.50 15.25 26.00 15.25 11.00 4.50 8.25 34.25 8.25 80.0 116.0 DN150 168.3 406 562 1080 387 660 387 279 114 210 870 210 36.2 52.6 8 8.625 17.50 23.02 44.50 18.50 30.00 16.00 12.25 4.75 8.25 36.25 9.25 122.0 158.0 DN200 219.1 445 585 1130 470 762 406 311 121 210 921 235 55.3 71.6 The 'A' dimension is the actual takeout dimension of the valve body. 2 The "Al" dimension is the actual takeout dimension of the valve body with water Supply main control valve. For systems with the optional Series 746-LPA Dry Accelerator, add 9.50 inches/241 mm to the "B" dimension to account for the additional height. NOTES 1 he drawings shown above reflect the electric AutoConvert dry release trim. In addition, these dimensions can be applied to the redundant solenoid valve configuration. components shown as dotted lines denote optional equipment. The recommended drain connection kit (shaded in orange) is for reference and takeout dimensions. This drain connection comes standard when the VQR assembly is ordered. S. 31.82 9999 Rev B Updated 02/2019 © 2019 Victaulic Company. All rights reserved. vuctaulic.com 6 JztauIicr S victaulic.com 4.2 DIMENSIONS A 4'YDN 100 valve with double-interlocked electric/pneumatic autoconvert dry release preaction trim is shown below 11/2 - 27DN40 - DN50 configurations contain 34'719mm drain valves 21/2 - 37DN65 - DN80 and 73.0 mm configurations contain 11/4"/31 mm drain valves 4- 8JDN100 - DN200 configurations contain 2750mm drain valves F Size Dimensions Weight Each Actual Outside Without With Nominal Diameter A' Al2 B3 C D Dl E F G H K Trim Trim inches inches inches inches inches inches inches inches inches inches inches inches inches lb lb DN mm mm mm mm mm mm mm mm mm mm mm mm kg kg 1½ 1.900 9.00 16.37 36.50 17.50 20.25 13.50 9.00 3.25 10.25 26.25 6.00 16.7 43.0 DN40 48.3 229 1 416 927 445 1 514 343 229 83 1 260 667 1 152 7.6 1 19.5 2 2.375 9.00 13.83 36.50 17.50 20.25 13.50 9.00 3.25 10.25 26.25 6.00 17.0 43.0 DN50 60.3 229 351 927 445 514 343 229 83 260 667 152 7.7 19.5 2½ 2.875 12.61 16.51 38.25 17.50 20.75 13.50 9.50 4.00 9.75 28.50 6.50 41.0 65.0 73.0 320 419 972 445 527 343 241 102 248 724 165 18.7 29.5 3.000 12.61 16.51 38.25 17.50 20.75 13.50 9.50 1 4.00 9.75 1 28.50 6.50 41.0 65.0 DN65 76.1 320 419 972 445 527 343 241 102 248 724 165 18.7 29.5 3 3.500 1 12.61 16.51 38.25 17.50 20.75 13.50 9.50 4.00 9.75 28.50 6.50 41.0 65.0 DN80 88.9 320 419 972 445 527 343 241 102 248 724 165 18.7 29.5 4 4.500 15.03 19.85 39.00 14.25 20.25 12.50 11.00 4.75 8.50 30.50 7.50 59.0 95.0 DN100 114.3 382 504 991 362 514 318 279 121 216 775 191 26.7 43.0 6.500 16.00 22.13 40.25 15.00 20.75 13.00 11.00 4.50 8.50 31.75 8.25 80.0 116.0 165.1 406 562 1022 381 527 330 279 114 216 806 210 36.2 52.6 6 6.625 16.00 22.13 1 40.25 15.00 20.75 13.00 11.00 4.50 8.50 31.75 8.25 80.0 116.0 DN150 168.3 406 562 1022 381 527 330 279 1 114 216 806 210 36.2 52.6 8 8.625 17.50 1 23.02 41.75 16.00 21.50 13.50 12.25 4.75 8.25 33.50 9.25 122.0 158.0 DN200 219.1 i 445 585 1060 406 546 343 311 121 210 851 235 55.3 71.6 The "A" dimension is the actual takeout dimension of the valve body. 2 The "Al" dimension is the actual takeout dimension of the valve body with water supply main control valve. For systems with the optional Series 746-LPA Dry Accelerator, add 9.50 inches/241 mm to the "B" dimension to account for the additional height NOTES The drawings shown above reflect the electric AutoConvert dry release trim. In addition, these dimensions can be applied to the redundant solenoid valve configuration. Components shown as doffed lines denote optional equipment. The recommended drain connection kit (shaded in orange) is for reference and takeout dimensions. This drain connection comes standard when the VQR assembly is ordered. 31.82 9999 Rev B updated 02/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com VA j#(ztauIic victaulic.com 4.3 DIMENSIONS A 4YDN 100 valve with double-interlocked pneumatic/pneumatic release preaction trim is shown below 11/2 - 2YDN40 - DN50 configurations contain A719 mm drain valves 2½ - 37DN65 - DN80 and 73.0 mm configurations contain 11/4731 mm drain valves 4 - 87DN100 - DN200 configurations contain 2750 mm drain valves Full Open Size Dimensions Weight Each Actual Outside Without With Nominal Diameter A' Al2 B3 C D D14 D24 E F G H K Trim Trim inches inches inches inches inches inches inches inches inches inches inches inches inches inches lb lb DN mm mm mm mm mm mm mm mm mm mm mm mm mm kg kg 11/2 1.900 9.00 1 16.37 36.00 9.25 1 21.25 11.00 23.50 9.25 3.25 10.25 25.75 6.00 16.7 43.0 DN40 48.3 229 416 914 235 j 540 279 597 1 235 83 1 260 654 152 7.6 19.5 2 2.375 9.00 13.83 36.00 9.25 21.25 11.00 23.50 9.25 3.25 10.25 25.75 6.00 17.0 43.0 DN50 60.3 229 351 914 235 540 279 597 235 83 260 654 152 7.7 1 19.5 21/2 2.875 12.61 16.51 37.75 11.25 22.50 12.50 24.75 9.50 4.00 9.75 28.00 6.50 41.0 65.0 73.0 320 419 959 286 572 318 629 241 102 248 711 165 18.7 29.5 3.000 12.61 16.51 37.75 11.25 22.50 12.50 24.75 9.50 4.00 9.75 28.00 6.50 41.0 65.0 DN65 76.1 320 419 959 286 572 318 629 241 102 248 711 165 18.7 29.5 3 3.500 1 12.61 16.51 37.75 11.25 22.50 12.50 24.75 9.50 4.00 9.75 28.00 6.50 41.0 65.0 DN80 88.9 320 419 959 286 572 318 629 241 102 248 711 165 18.7 29.5 4 4.500 15.03 19.85 38.50 13.50 23.75 13.50 26.25 10.00 4.75 8.50 30.00 8.00 59.0 111.0 DN100 114.3 382 504 978 343 603 343 667 254 121 216 762 203 26.7 50.3 6.500 16.00 22.13 39.25 1 14.00 24.50 13.25 27.75 11.00 4.50 8.25 31.00 8.25 80.0 132.0 165.1 406 562 997 1 356 622 337 705 279 114 210 787 210 36.2 59.8 6 6.625 16.00 22.13 39.25 14.00 24.50 13.25 27.75 11.00 4.50 8.25 31.00 8.25 80.0 132.0 DN150 168.3 406 562 997 356 622 337 705 279 114 210 787 210 36.2 59.8 8 8.625 17.50 23.02 41.25 14.75 27.00 13.50 29.75 12.25 4.75 8.25 33.00 9.25 122.0 174.0 DN200 2191 445 1 585 1048 375 686 343 756 311 121 210 838 235 55.3 78.9 The "A" dimension is the actual takeout dimension of the valve body. 2 The "Al" dimension is the actual takeout dimension of the valve body with water supply main control valve. For systems with optional Series 746-LPA Dry Accelerators, add 11.50 inches/292 mm to the "B' dimension to account for the additional height. The "D" and "Dl" dimensions are not fixed measurements. The drip cup can be rotated to provide more clearance at the back of the trim. NOTES Components shown as dotted lines denote optional equipment. The recommended drain connection kit (shaded in orange) is for reference and takeout dimensions. This drain connection comes standard when the VQR assembly is ordered. S. 31.82 9999 Rev B Updated 02/2019 © 2019 Victaulic Company. All rights reserved. vlctauIKcom 8 Ltauiicr victa ulic .com 5.0 PERFORMANCE Hydraulic Friction Loss The chart below expresses the flow of water at 65017/180C through an open valve. sui1i auuuu. 111111 UuulIII _.uhiil uuiiuiimunuasusii IIIIIIIIAWIIIVW1IIIIIO Atilli.: • 111I Y/AII =0 111111 ~mmus; Mai UI 11uu1 ____ =a uiuiui____ I .aiuuui IM ll~lllmlm wiaiii ill uuii MEN 1111 110111111111111101 111111. 1111111 .rlull 1111111 ___ 11111111 1111111 20 30 49 60 80100 200 300 400 600 1,000 2,000 4,000 6,000 10,000 20,000 800 3,000 8,000 FLOW RATE - GPM 6.0 5.0 4.0 3.0 - 2.0 U, 0. 0 C) 1.0 0.9 o 0.8 IJJ 0.7 0.6 05 U, u, 0.4 IJ IM 0.3 0.2 Frictional Resistance The chart below expresses the frictional resistance of Victaulic Series 769N FireLock NXTr. Preaction Trim in equivalent feet of straight pipe. Size Equivalent Actual Nominal Outside Diameter Length of Pipe inches inches feet DN mm meters 11/2 1.900 3.00 DN40 48.3 0.914 2 2.375 9.00 DN50 60.3 2.743 21/2 2.875 8.00 73.0 2.438 3.000 8.00 DN65 76.1 2.439 3 3.500 17.00 DN80 88.9 5.182 4 4.500 21.00 DN100 - 114.3 6.401 6.500 22.00 165.1 6.706 6 6.625 22.00 DN150 168.3 6.706 8 8.625 50.00 D 20 219.1 15.240 Cv Values: Cv values for flow of water at +60°F/+16°C through a fully open valve are shown in the table below. Formulas for Cv values Where: AP=Q2ICv2 Flow Coeff icient Q = Cs x 'fLIP Cv 0 (Flow) GPM Size Full Open Actual Outside Nominal Diameter Flow Coefficient inches inches Cv DN mm Ky 11/2 1.900 60 DN40 48.3 52.0 2 2.375 110 DNSO 60.3 95.0 21/2 2.875 - 180 J 73.0 156.0 3.000 180 DN65 76.1 156.0 3 3.500 200 DN80 88.9 173.0 4 4.500 350 DN100 114.3 302.8 6.500 1000 165.1 865.0 6 6.625 1000 DN150 168.3 865.0 8 8.625 1500 DN200_ 219.1 1297.5 LIP (Pressure Drop) psi 31.82 9999 Rev B Updated 02/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com J:3tluIiC• victaulic.com 5.0 PERFORMANCE (Continued) Air Supply Requirements Minimum: 13 psi/90 kPa/.9 bar regardless of the system water pressure Maximum Recommended: 18 psi/124 kPa/1.24 bar Sizing the compressor: Engineer/system designer is responsible Entire system must be charged to the required air pressure within 30 minutes to meet NFPA requirements An oversized compressor will slow down or possibly prevent valve operation Compressor filling the system too fast: May be necessary to restrict the air supply Ensure that air exhausted from an open sprinkler or manual release valve is not replaced by the air supply system as fast as it is exhausted Compressor Requirements Base or Riser Mounted Compressors: On" or low" pressure setting: 13 psi/90 kPa/.9 bar "Off" or high" pressure setting: 18 psi/124 kPa/1.24 bar Victaulic Series 7C7 riser mounted and pre-set for pressure requirements (refer to Victaulicpublication 30.22). If the compressor is not equipped with a pressure switch, the Series 757P Air Maintenance Trim Assembly with pressure switch should be installed (refer to Victaulic oublication 30.36). Shop Air or Tank-Mounted Air Compressors: . • Series 757 Regulated Air Maintenance Trim Assembly should be installed (refer to Victaulic publication 30.35) 13 psi/90 kPa/.9 bar should be used as the set point for the air regulator The compressor cut-in (turn-on) pressure setting should be at least 5 psi/34kPa/34 bar above the set point of the air regulator. Exploded View Trim: Series 757 Regulated Air Maintenance Trim Assembly (refer to Victaulic publication 30.35) Compressor Requirements and settings for systems installed with Series 746 or Series 746-LPA dry accelerators A tank-mounted air compressor with a Series 757 Regulated AMTA must be used to supply air to system installed with a Series 746 or Series 746-LPA Dry Accelerator. In the event a compressor becomes inoperative, a properly sized tank-mounted air compressor provides the greatest protection, since air can be supplied continuously to the sprinkler system for an extended time period. Electrical Release Requirements Verify that an approved control panel is installed for proper system operation. S 31.82 9999 Rev B updated 02/2019 © 2019 Victaulic Company. All rights reserved. 10 virtaulic.com 5.0 PERFORMANCE (Continued) Autoconvert Requirements System must be installed in conjunction with a Notifier RP-2001 family panel, System Sensor PDRP-2001, or a Potter 4410RC panel to be in compliance with FM Approvals. AutoConvert Trim: In the event of an AC power loss, the AutoConvert module latches from Closed to Open with a quick electrical pulse. To stay open, no further current draw is required as would be needed in a normally open solenoid. This opened pathway allows the included Series 776 Low Pressure Actuator to operate as a dry actuator, putting the preaction system into a Non-Interlocked condition. In this case, an electrical release from the FACP and an air loss in the system or the system air loss would allow the Series 769N valve to actuate, filling the pipe with water. Upon an AC power return, the Auto-Convert module senses the restoration and latches the path from the Series 776 Low Pressure Actuator closed, returning the preaction valve to its standard release method. 6.0 NOTIFICATIONS .... ______ • Read and understand all instructions before attempting to install any Victaulic products. Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal, adjustment, or maintenance of Q any Victaulic products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. 31.82 9999 Rev B Updated 02/2019 © 2019 Victaulic Company. All rights reserved. victaulic.corn 11 victaulic.com 7.0 REFERENCE MATERIALS 30,22 FireLockTM Compressor Package Series 7C7 30.23: FireLockTM Fire-Pac Series 745 30.32 pireLockiM Water Motor Alarm Series 750 30.33: Supplemental Alarm Kit Series 75B 30.34: Automatic Water Column Drain Kit for FireLock NXTTM Valves Series 75D 30.35: FireLockiM Air Maintenance Trim Assembly Series 757 30.36: FireLnckTM Air Maintenance Trim Assembly Series 757P 30.41: FireLocWr Manual Pull Station Series 755 30.61: FireLockaM Double-Pneumatic Actuator Series 798 30.62: FireLock1° Low Pressure Actuator Series 767 30.63: FireLocWr Electric Solenoid Series 753E 30.64: FireLocklM Div Accelerator Series 746-LPA 30.65: FireLpcklr Low Pressure Actuator Series 776 30.84 FireLock NXTTM AutoConvert Trim Assembly for Preactign Devices 1-769N.Preoction 1-769N Preaction/DPA t-769N.Preaction/EPA -769 N,Preaction/AC-Elec 1-769N .Preaction/AC-EP Scan for reference documents. User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, nary, supersede, or waive any provision of Victaulic Company's standard conditions at sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right at Victaulic or any of its subsidaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods at use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be instated in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the might to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in POE format on our webuite at www.oictaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks at Victaulic Company, arid/sr its affiliated entities, in the U.S. and/or other countries, 31.82 9999 Rev B Updated 02/2019 © 2019 Victaulic Company. All rights reserved, victauUcom 12 ,J3t _Su Iicr Bulletin 013 November 2019 Rella bl 0 Models Fl Series Standard Response Sprinklers Model F156 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model Fl 56 Recessed Sprinkler Types Pendent/Fl/F2/FP Horizontal Sidewall Model F142, F1XLH & F128 Sprinkler Types Standard Upright Standard Pendent Model F142, F1XLH & F128 Recessed Sprinkler Types Pendent!F1/F2/FP Approval Organizations Underwriters Laboratories Inc. and certified for Canada (cULus) Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS Schadenverhutung GmbH EC Certificate: 0786-CPD-40237 (RA1314) 0786-CPD-40253 (RA1325) 0786-CPD-40254 (RA1375) UL Listing Category Sprinklers, Automatic & Open (VNlV) Product Description The F156, F142, F1XLH & F128 Series Glass Bulb Sprinkler combines the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. Whether installed on exposed piping or in an office ceil- ing, it is functional and attractive. Beautifully versatile is the description for the Reliable Models F156, F142, F1XLH & F128 Series Recessed glass bulb sprinkler. Recessing the F156, F142, F1XLH & F128 Series enhances its already low profile decorative appearance, and facilitates a rapid and perfect installa- tion. The recessed escutcheon of the Models F156, F142, F1XLH & F128 are highly adjustable. The two piece con- struction makes field installation a very easy and rapid task. This also allows ceiling panels to later be removed without shutting down the fire protection system, thus fa- cilitating maintenance of above ceiling services. Pendent'F1/F2 Horizontal Sidewall PendenljFP Pendent F1 /F2 Pendent FP The F156, F142, F1XLH & F128 Series Automatic Sprin- kler utilizes a 5.0 mm frangible glass bulb. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid phase and in the vapor phase. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distribute the discharging water. The F156, F142, F1XLH & F128 Series Sprinkler tem- perature rating is identified by the color of the glass bulb capsule as well as frame color where applicable. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Pin tie (XLH Only) Deflector Load Screw Washer Bulb Frame Cup 0 13FG04 Model F142, F1XLH Upright Technical data: C *Note: Model F156 upright, pendent, and recessed pendent sprinklers (SIN RA1325 and RA1314) are cULus Listed for 250 psi (17 bar). 2. Thread Max. Mm. Temperature Models Nominal K-Factor Response Size Working Working Rating Finish Pressure Pressure F156 5.6 (80 Metric) 250 PSI* 1/2" NPT See See F142 F1XLH 4.2 (60 Metric) Standard (R½) 7 PSI Temperature "Finish Table" 175 PSI Ratings" Table F128 2.8 (40 Metric) Material Data: Frame Deflector Load Screw Pintle Cup Washer Bulb CDA Alloy 260, CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 DZR Brass CDA Alloy 220 or or or coated with PTFE Adhesive Glass OM Brass or CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape CDA Alloy 510 I 21/CRDLED/U r UR H r-1 rD,/2 DRONED 5)55 COLLAR 1' UOCSCR MOSS_\ bi TO PACE RE AT MADXAUM RECESS - 725.4R,RTJ ATM/N/MUM RECESS - 3/fl AT MAXIMUM RECESS - 3/47)O.R] AT MINIMUM RECESS 3/879.5TTs) AT MAXIMUM RECESS - 7/8122.25,N1 'AT MIS/MUM RECESS = )-5/8741.JRTT.Tj AT MAXIMUM RECESS - ))/8 726 OR,., AT MMPMUM RECESS - H—' —H RECESSED PENDENT W/11 OR 12 ESCUTCHEON SPRISRLER NOT FM APPROVED FIRS ES ESCUTCHEON Model F156, Upright, Pendent & Conventional Sprinklers Model F142, F1XLH & F128 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench or Model W2 Sprinkler Wrench Installation Data: Nominal Orifice Thread 1 Size Nominal K-Factor ______________ Sprinkler Height Approval Organizatio n Sprinkler Identification Number (SIN) US I Metric Upright I Pendent ____________________________ Standard -Upright (SSU) and nendent Deflectors Marked to Indicate Position ½" (15mm) (1) 1/2" NPT (R1/2) 1 5.6 I 80 2.25" (57mm) 1.2.3,4,5 I RA1314 356 /i6 (10mm) ½" NPT (R½) 1 4.2 I 60 2.25" (57mm) 1 E RA1323 26 I RA1313 3/s"(10mm) ½" NPT (R1/2) ] 2.8 I 40 25" (57mm) 1 1 1 RA132126 I RA 1311(6) Conventional-Install in Upright or Pendent Position 15mm (1) I ½" NPT (R½) I 5.6 I 80 I 57mm I 3, 4, 5 1 RA13755 Refer to Bulletin 024 for Special Response Sprinklers (F1S5-56) cULus Listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM Approved sprinkler. Polyester coated LPCB & VdS approved sprinkler RA1325, RA1314 & RA1375. Electroless Nickel PTFE Plated - UL listed corrosion Resistant Upright Pendent Conventional 10 Installation F156, F142, F1XLH & F128 Recessed Pendent Sprinklers(" Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size Nominal K-Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric ½"(lSmm) 1/2" NPT (R1/2) 5.6 80 2.25" (57mm) RA1314 2 7A6" (10mm) ½" NPT (R1/2) 4.2 60 2.25" (57mm) RA1313 2 3/511 (10mm) ½" NPT (R1/2) 2.8 40 2.25" (57mm) RA13112 Refer to escutcheon data table for approvals & dimensions (2) Electroless Nickel PTFE Plated - cULus listed corrosion Resistant I I I" X I/2 REDUCER 2 - HOLE IN CEILING I r 2 5/16 0)2. 158.7R,03 - J CUP CE/V/SC ___ 4 FACE OF FIST/SC I TO FACE OF CE/CISC 0/MEWS/CS L ATMRXIMUM RECESS - 9/16714.5ssJ C1750 8s,s'1 _J AT MIS/MUM RECESS - 1725.-] AWUSTUENT 3 114' DA - I [62.Oss] RECESSED PENDENT w/rp ESCUTCHEON DIAeSOAR -SPRINKLER NOT EM APPROVED 0/5/1 PP ESCUTCHEON [jj 3. Vertical Sidewall Sprinkler Type Deflector to Ceiling Distance (Min. - Max.) Upright 4" (102mm) - 12" (305mm) Pendent 4" (102mm) - 12" (305mm) Installation Data: Model F156 Vertical Sidewall Sprinkler Installation Wrench: Model W2 Sprinkler Wrench Installation Position: Upright or Pendent . Approval Type: Light Hazard Occupancy U.S. Patent No. 6,374,920 Nominal Orifice Thread Size I Nominal K Factor Sprinkler Height Approval (1) I Organizations Sprinkler Identification I US I I Metric Numbers (SIN) 1/2"(15mm) ½" NPT(R½) 5.6 80 2.25" (57mm) 1,2,3 LPC Approval is pendent only, 57°C through 141°C ratings. cULus Listed corrosion resistant (Polyester coated) sprinkler. ° cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead. (4) Electroless Nickel PTFE Plated - cULus listed Corrosion Resistant Model F156 Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model W2 Sprinkler Wrench { FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1'[25.4—] AT MINIMUM RECESS .3/8"[9.5r,v,j F2 ESCUTCHEON AT MAXIMUM RECESS AT MINIMUM RECESS = .3/879,5mr,J 1-2 1/4" HOLE 0(4. [57.2rj X 1/2"REDUCER - Horizontal Sidewall Installation Data:Horizontal Sidewall Fl ESCUTCHEON (LI AT MAXIMUM RECESS l-3/8"[34.9,,,,,,] AT MINIMUM RECESS 2-1116"[52.4—] / F2 ESCUTCHFON I AT MAXIMUM RECESS = 1-518"[4 I.-m] AT MINIMUM RECESS = 2-I/I6752.4rn] l (3.2,'] 4-12" 15116" OIA [101.6mo-jO4.8,r,,] 2 27/32" D CEILING TO U [72.2r,,,] DEFLECTOR TURN COLLAR UNTIL TIGHT AGAINST WRENCH BOSS,SPRINKLER Fl ESCUTCHEON —I 3/4"[19,,] ADJUSTMENT F2 ESCUTCHEON 1/2712. ADJUSTMENT RECESSED HSW W/F1 OR '2 ESCUTCHEON (I) FM APPROVED FOR 4 - 6" [101.644M - /52.444M] CEILING TO DEFLECTOR, For Recessed HSW Sprinklers use installation wr FM and cULus permits use with Fl or F2 escutcheons for "Light Hazard" only. Nominal K Factor Sprinkler Height __________________ Approval Organizations Sprinkler Nominal Orifice Thread Size Identification US Metric Light Hazard Ordinary Numbers (SIN) Hazard ½" (15mm) ½" NFl (R1/2) 5.6 80 1 2.63" (67mm) 1 1,2 1 11cULus Listed corrosion resistant (Polyester coated) sprinkler. I21 cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead, .Polyester coated FM approved sprinkler. (4) Electroless Nickel PTFE Plated - cULus listed Corrosion Resistant 4. C Application Model F156, F142, F1XLH, F128& Model F156, F142, F1XLH & Fl 28 Recessed sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Reaction. Care must exercised that the orifice size, temperature rating, deflector style and sprinkler type are in ac- cordance with the latest published standards of the National Are Protection Association or the approving Authority Having Junsdic- fion Installation. Installation Model F156, F142, F1XLH & F128 Series sphnklers are stan- dard response sprinklers intended for installation as specified in NFPA 13. They must also be installed with the Model W2 Sprinkler Wrench specifically designed by Reliable for use with these sprin- klers. The Model F156, F142, F1XLH & F128 Recessed Sprinklers are to be installed with a maximum recess of 3/4 inch (19mm). The Model Fl, F2, and F Escutcheon illustrated are the only recessed escutcheon to be used with the Model F1 56, F142, F1XLH & F1 28 Recessed Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model F156, F142, F1XLH & F128 Recessed Sprinklers use the Model GFR2 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Note: A leak fight 1/2" NPT (R½) sprinkler joint can be obtained with a torque of 8- 18 ft-lbs (11 -24 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impair- ment of the sprinklers. Glass bulb sprinklers have orange covers to protect the bulb dur- ing the installation process. REMOVE THIS PROTECTION ONLY AFTER THE SYSTEM HAS BEEN HYDROSTATICALLY TESTED AND, WHEN APPLICABLE, THE ESCUTCHEONS HAVE BEEN INSTALLED. RASCO wrenches are designed to install sprinklers when covers are in place. Ordering Information Specify: Sprinkler Model Sprinkler Type Nominal K-Factor Temperature Rating Sprinkler Finish Thread Type: [1/2" NPT] [ISO 7-1R1/2] Escutcheon Finish (where applicable) Note: When Models F156, F142, F1XLH & F128 Recessed Sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Escutcheon Data (1) (1) SIN: RA1335 - cULus and FM permits use with Fl or F2 escutcheons for light hazard only Maintenance The Model F156, F142, F1XLH & Model F156, F142, F1X- LH & F128 Recessed Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluid. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause im- proper operation or non-operation. Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color °C °F Ordinary 57 135 100°F (38°C) Orange Ordinary 68 155 100°F(38°C) Red Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green High0 141 286 225°F(107°C) Blue Extra High111 182 360 300°F (149°c) Mauve Ultra High (1)(2) 260 500 475°F (246°c) Black Not available for recessed Sprinklers. 2) cULus listed for SIN RA1325 and RA1314 only. Maximum Working Pressure 175 psi (12 bar) SIN RAl 325 & RA1314 cULus listed for 250 psi (17 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finish(1) Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Chrome Polyester Coated (6)(7)(9) White Painted Special Application Finishes Sorinkler Escutcheon Electroless Nickel PTFE13°°1 Electroless Nickel PTFE Bright Brass'2 Bright Brass Black Plated Black Plated Black Paint13191 Black Paint Off White(3119) Off White Chrome Dull Chrome Dull Lead Plated(311418) Wax Coated(3114115)18 Wax Over Lead (3)(4)(5)(8) (1) Other colors and finishes are available on special order. Consult factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. 2)200°F (93°C) maximum. (3) UL and ULC listed only (4)155°F to 200°F (68°C to 93°C) ratings only. 151286°F (141°C) sprinklers may be coated for ambient conditions not exceeding 150°F (66°C). cULus listed 'corrosion resistant" applies to SIN Number RA1325 (Upright) RA1323 (upright), RA1321(Upright), RA1335 (HSW), RA1385(VSW) and RA1314 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approved finish as 'Polyester Coated" applies to SIN number RA1314, RA1335 & RA1325 in standard black or white. ) FM Approved finish applies only to SIN number RA1335 & RA1385. (1) LPCB and VdS Approved finish applies only to RA1325, RA1314 and RA1375. 10 cULus listed Corrosion Resistant applies to SIN R.A1325 ,RA1314 ,RA1323, RA1313 ,RA1321, RA1311, RA1385 and RA1335 5. Reliable ... For Complete Protection S Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled (800) 431-1588 Sales Offices Paper (800) 848-6051 Sales Fax Revision lines indicate updated or new data. Rellabile (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address [0. Printed in U.S.A. 11/19 P/N 9999970299 FireLockTM V38, K5.6 Ltauiic S Models V3801, V3802 40.50 \ V3801 and V3802 1.0 PRODUCT DESCRIPTION Models: V3801 and V3802 Style: Adjustable Concealed, Ordinary Hazard and Light Hazard K Factor: 5.6 Imp./8.1 SI.' Nominal Thread Size: ½ NPT/15 mm BSPT Max. Working Pressure: 175 psi/1207 kPa/12 bar Factory Hydrostatic Test: 100% © 500 psi/3447 kPa/34 bar Mm. Operating Pressure: 7 psi/48 kPa/0.5 bar Temperature Rating: See chart in section 2.0 For K-Factor when pressure is measured in bar, multiply S.I. units by 10.0. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date viCtauliC.Com 40.50 2558 Rev P Updated 01/2019 © 2019 victaulic company. All rights reserved. ictaulic 1 victaulic.com p 2.0 CERTIFICATION/LISTINGS ®" 'zZ (( [LPCBJ LISTED 0832 104-1 a/02 Approvals/Listings Approvals/Listings Model V3801 V3802 Orifice Size (inches) i 1/2 Orifice Size (mm) 13 13 Nominal K Factor Imperial 5.6 5.6 - Nominal K Factor Metric 5.1.2 8.1 8.1 Response Standard 5 m bulb Quick3 3 m bulb Deflector Type Concealed Pendent Concealed Pendent Adjustment 1/2"/13 mm 1/2"/13 mm Approved Temperature Ratings P/C" 135"F/57"C 135"F/57"C cULus 155°F168"C 155"F/68"C 175°F/79"C 175"F/79°C 200"F193°C 200"F/93"C 155"F/68"C FM3 NONE 175°F/79°C 200"F/93"C 135"F/57"C 135°F157"C NYC/MEA3 #62-99-E 155°F/68°C 155°F/68°C 175"F/79"C 175"F/79°C 200"F/93"C 200°F/93"C 135°F/57"C 135"F/57°C CS FM3 #7690-0531:112 155"F168"C 155"F/68°C 175°F/79"C 175"F/79"C 200"F193"C 200"F/93"C 155"F168°C Sprinkler/1 38"F/59"C Cover 155"F/68"C Sprinkler/138"F/59"C Cover LPCB 175"F179"C Sprinkler/165°F/74"C Cover 175"F/79"C Sprinkler/1 65"F174"C Cover 200°F193"C Sprinkler/165°F/74°C Cover 200"F/93"C Sprinkler/1 65°F174°C Cover 135°F/57°C 135°F/57°C 155"F/68"C 155°F/68"C VNIIPO 175"F/79"C 175°F/79°C 200"F/93"C 200°F/93"C 286°F/141"C 286°F/141"C ZSTDY K ZSTDY CCC 155°F/68"C 155"F168"C 200°F193"C 2 For K-Factor when pressure is measured in bar, multiply S.I. units by 10.0. Recognized by FM as standard response only. NOTE Listings and approvals as of printing. All are approved open. 40.50 2558 Rev P Updated 01/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 2 JtauIicr l,irt,, il,t mm 3.0 SPECIFICATIONS - MATERIAL Deflector: Bronze Cover Plate: Fusible solder Bulb: Glass with glycerin solution Bulb Nominal Diameter: O Standard: 5,0 mm O Quick Response: 3,0 mm Load Screw: Bronze Pip Cap: Bronze Spring: Beryllium Nickel Seal: Teflon4 tape Frame: Brass Pins: Stainless steel Cup: Cold rolled steel, zinc chrome plated Cover/Escutcheon: Brass Lodgement Spring: Stainless steel Protective Cap: Polyethylene Installation Wrench: o Concealed: V38-4 or V38-5 Sprinkler Finishes: U Plain Brass (only) Cover Finishes: 0 Chrome Plated O White painted5 0 Flat Black Painted5 0 Custom Painted5 Teflon is a registered trademark of Dupont co. UL Listed for corrosion resistance. 40.50 2558 Rev P Updated 01/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 3 4tauiicr MINIMUM EXTENSION Finished Surface 2//68 mm Max. Hole 2//6O mm Mm. Hole 2//'/59 mm 1½738 mm 2/51 mm 1/2713 mm Adjustment victaulic.com 4.0 DIMENSIONS (drawings not to scale) Finished Surface MAXIMUM EXTENSION (drawings not to scale) 5.0 PERFORMANCE Sprinkler is to be installed and designed as per NFPA, FM Datasheets, or any local standards. 6.0 NOTIFICATIONS £RJIi . Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. 0 Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet , that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. fl 40.50 2558 Rev P Updated 01/2019 © 2019 Victaulic Company. All rights reserved. .1:... 4 'J -0 ta u Ii c S victaulic.com I 7.0 REFERENCE MATERIALS Ratings: All glass bulbs are rated for temperatures from —67°F (-55°C) up to those shown in table below. Sprinkler Sprinkler - V3801, V3802 Cover - V38 Temperature Classification Victaulic Part Identification Temperature - °F/°C Glass Bulb Color Victaulic Part Identification Temperature - WC Nominal Temperature Rating Maximum Ambient Temperature Allowed Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135°F/570C 100°F/38°C Orange - As 1350F/570C 100°F/38°C Ordinary C 155°F/68°C 100°F/38°C Red D7 165°F/74°C 150°F/65°C Intermediate E 175°F/79°C 150°F/65°C Yellow Intermediate F 200°F/93°C 1500F1650C Green High J 286°F/1410C 225°F/1 07°C Blue Extra High" K 360°F/1820C 300°F/149°C Purple - M Open - No Bulb A For use with Standard or Quick Response Concealed Sprinkler 135F/57C or 155F/68C. 0 For use with Standard or Quick Response Concealed Sprinkler 175°F/79°C or 2007/93°C, 8 138°F/59°C per LPCB NOTE Custom Finish - Customer to provide paint specification, allow 4-6 weeks for samples. Available Wrenches: Sprinkler Type Recessed Concealed Pendent -V3801, V3802 V38-4 or V38-5 29.01 Victaulic® Terms and Conditions of Sale 1-0 Victaulic® FireLockTM Automatic Sprinklers User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer lathe Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/sr its affiliated entities, in the U.S. and/us other countries. 40.50 2558 Rev P Updated 01/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 5 J _C_ tauiicr FireLock® V27, K5.6 Models V2703, V2707, V2704, V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response V2703/V2704 V2707/V2708 V2707/V2708 Upright Pendent Recessed Pendent Approvals/Listings: 07% See Victaulic Publication 10.01 for more details. Product Description: These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for . standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to /41719 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. \4taulicr 40.10 Technical Specifications: Models: V2703, V2704, V2707, V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1/2713 mm K Factor: 5.6 Imp./8.1 S.l.' Nominal Thread Size: ½" NPT/15 mm Max. Working Pressure: 175 psi/1200 kPa (FM) 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart I For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Exaggerated for clarity Job/Owner System No. Location Contractor Submitted By Date Engineer Spec Section Paragraph Approved Date victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. 1 \4tau1icr victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Material Specifications: Upright Deflector: Bronze per UNS C11000 Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: El Standard: 5.0 mm El Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Accessories Installation Wrench: Open End: V27 El Recessed: V27-2 Sprinkler Finishes: El Plain Brass El Chrome plated El White painted3 LII Black painted3 El Custom painted3 LII Proprietary Nickel Teflon2 coating3 VC-250 155, 200, 286 SR Only: El Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont Co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. 40.10 2544 Rev. j updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 2 4tauiicr victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Approvals/Listings: Model APPROVALS/LISTINGS V2703 V2707 V2707 V2704 V2708 V2708 Orifice Size (inches) 1/2" 1/2" 1/2" 1/2' 1/2" 1/2' Orifice Size (mm) 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.1.5 8.1 8.1 8.1 8.1 8.1 8.1 _Response Standard Standard Standard Quick Quick Quick Deflector Type Upright Pendent Recessed Upright Pendent Recessed Pendent Pendent Approved Temperature Ratings F"/C" 135°F/57°C 135°F/57°C 135°F/57°C 135"F/57°C 135°F/57°C 1550F/680C 155"F/68°C 1550F/680C 155"F/68"C 155"F/68°C 135°F/57°C cULus 175"F179°C 175"F179°C 175°F/79°C 175°F179"C 175"F179"C 155°F/68"C 200"F/93"C 200"F/93"C 200"F1930C 200"F/93°C 200"F/93"C 1750F/79°C 286"F/141°C 286"F/141 °C 286"F/1410C 286°F/141°C 286°F/1410C 200"F/93°C 360"F/182"C 360"F/182"C 1350F/57°C 135"F/57°C 1350F/570C 135°F/570C 155°F/68°C 155"F/68°C 135°F/570C 1550F/68°C 155°F/68"C 135°F/57°C FM 175"F/79"C 175"F/79"C 155"F/68"C 175°F179°C 175°F/790C 155°F/68°C 200°F/93°C 200°F/930C 175°F/790C 200°F/93°C 200°F/930C 175°F/79"C 286"F/141"C 286°F/141"C 200"F/930C 286"F/141°C 286°F/141°C 200°F/93"C 360"F/182"C 360°F/1820C 135"F157°C 135"F/57"C 135°F/570C 135°F/570C 135°F/570C 155"F/68"C 155"F/680C 1550F/68"C 1550F/68"C 155°F/680C 135"F157°C NYC/MEA 62-99-E 175°F/79"C 175"F/790C 175"F/79"C 175"F/79"C 175°F/79"C 155°F/68°C 200"F/930C 200"F/93"C 200"F/93"C 200°F/93"C 200"F/93"C 175"F/79"C 286"F/141°C 286"F/141°C 286°F/141"C 286°F/1410C 286°F/141°C 360"F/182°C 360"F/1820C 135°F/57°C 135°F/570C 135"F1570C 135°F/57"C 135°F/570C 155°F/68°C 1550F/680C 155°F/680C 1550F/68"C 1550F/68°C 135°F/57°C CSFM 7690-0531:112 175"F/79°C 175°F/790C 175°F179°C 175"F/79"C 175°F/79°C 155"F/68°C 200"F/93"C 200°F/93"C 200"F1930C 200"F/93"C 200°F/930C 175°F/790C 286"F/141°C 286°F/141 "C 286"F1141"C 2860F/1410C 286°F/141°C 200"F/93"C 360"F/182°C 360°F/1820C 155°F/680C 1350F/570C LPCB 1 75°F/79"C None None 155°F/68°C None None 200°F/93"C 175"F/79°C 286"F/141"C 200"F/93°C 135"F/57°C 1350F/57°C 135°F/570C 135°F/57"C 155°F/680C 155"F/680C 135"F/570C 155°F/68°C 155°F/68 °C 1350F/57"C VNIIPO 175°F/79°C 175°F/79"C 155°F/68 °C 175°F/79"C 175°F/79"C 200°F/93"C 200°F/930C 175°F/790C 200"F/93°C 200"F/93"C 175°F/790C 286°F/1410C 2860F/141°C 200"F/93°C 286"F/141°C 286°F/141°C 200"F/93°C 360"F/182°C 360°F/1820C ZSTZ ZSTX K-ZSTZ K-ZSTZ CCC 155"F/68°C 155"F/68"C None 155°F/68°C 155°F/68"C None 200" F/93°C 200°F/930C 200°F/930C 200" F/93°C 135OF/57'C 135'F/57'C 155°F/68°C VdS None None 1750F/790C None None 200"F/93°C 200"F/93"C 2860F/1410C 286"F/141°C 360°F/1820C 135°F/57"C 135"F/57"C 155°F/68°C 155°F/68"C CE 175"F/79"C None None 175"F/79°C None None 200"F/93°C 200°F/930C 286"F/141°C 286°F/1410C 360°F/1820C For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 FM Approved with 112' adjustment escutcheon only - quick response Note: Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev. j updated 07/2014 © 2014 Victaulic Company. All rights reserved. ,htaulic victaulic.com 3 , 37 mm 2 60 2W! 41 mm 60 mm victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Dimensions: S Standard Pendent - Standard Upright - V2707. V2708 V2703, V2704 2W/60 mm Max, Hole 2751 mm Mm. Hole - lIt,! 17mm Typical Ceiling Tile I- Finished Surface 30 nm 43 MAXIMUM RECESS 75 mm MAXIMUM EXTENSION ½' Adjustment Recessed - V2707, V2708 (drawing not to scale) 255 mx mm Max. Hole 2751 rn Min. Hole 37 rn Typical Ceiling Tile 24 mm 4 \—Finished Surface T d17 MAXIMUM RECESS 24 mm 75 mm MAXIMUM EXTENSION 3/4"Adjustment Recessed - V2707, V2708 (drawing not to scale) 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 4 \/1tauIicr victaulic.corn I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Distribution Patterns: Models V2707, V2708 K5.6 Standard Pendent and Recessed Pendent 10' 3,On 8' 2.4r,, 6' 1.8r,, 4. 1.2n4 2- 0.6m N 7psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa 2' 4' 6' 8' 10' 12' 14' 0.64, 1.24, 1.8. 2.4,4 3.54, 3.7,4 4.34, Models V2703, V2704 K5.6 Standard Upright Distribution Patterns - Trajectory % 6. .s.. -----.';——...----—--- -----N-i "..------- - - - - - — ---\ —A-L % 4 L % I % 2' 4' 6' 8' 10' 12' 14' 16' 0.64, 1.2m 1.84, 2.44, 3.5,, 3.7nn 4.3m 4.9m NOTES Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 5 tauIic 8' 2.4m 6- 1.8r6 4- 1.2n, 2- 0.6n, 0 7ps1 48 kPa 15 psi 103 kPa 30 psi 207 kPa victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Ratings: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135°F/570C 100°F/38°C Orange Ordinary C 155°F/68°C 1000F/38°C Red Intermediate E 175°F/79°C 150°F/65°C Yellow Intermediate F 200°F/930C 150°F1650C Green High J 286°F/141°C 225°F°I1070C Blue Extra High 7 K 360°F/182°C 300°F/149°C Purple - M Open - No Bulb Standard response only. 8 150/65 if wax coated. Available Wrenches: V27-2 Recessed V27 Open End V2707, V2708 Pendent V2707, V2708 Recessed Pendent V2703, V2704 upright Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. O Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. 10 Installation Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers Installation and Maintenance Sheet for the product you are installing. This installation sheet is included with each shipment of Victaulic products for complete installation and assembly data, and is available in PDF format on our website at victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic is a registered trademark of Victaulic Company. r L 40.10 2544 Rev. j updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 6 htauiic SCHEDULE 10 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES In. mm In. I mm In. mm Ibs./ft. kg/rn CRR Lift 1% 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 11/2 1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 2 2.375 60.3 2.157 54.8 .109 2,77 2.64 3.93 4.7 37 21/3 2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 4 4.500 114.3 4.260 108.2 .120 3.05 5.62 8,37 1.6 19 5 5.563 141.3 5.295 134.5 .134 3,40 7.78 11.58 1.5 13 6 6.625 168.3 6.357 161.5 .134 3.40 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 Calculated using Standard UL CRR formula, UI. Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe Is used as the benchmark (value of 1.0). SCHEDULE 40 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES In. mm in. mm In. mm Ibs./ft. kg/rn CRR L Lift 1 1.315 33,4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 1% 1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 1% 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 2 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR Is ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). @ C(s) <.~.OVE>D FM Approved and Fully Listed Sprinkler Pipe Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, C-UL and FM Listed. Approvals and Specifications Both products meet or exceed the following standards: ASTM A135, Type E, Grade A (Schedule 10) ASTM A795, Type E, Grade A (Schedule 40) NFPA13 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe up to 6" receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that • outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black, or with hot-dip galvanizing, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is also UL Listed. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: BLACK fl HOT-DIP GALVANIZED I,WheatlandTube JMC STEEL GROUP DUCTILE IRON eI'IDEG. ELBOW NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WEIGHT' A EACH I B PIECE I DB90033 500 1.50 1.50 0.62 11/4 DB90044 500 1.75 1.75 0.90 11/2 1 DB900551 500 1.94 1.94 1.20 2 1 DB900661 500 2.25 2.25 1 1.85 -- DUCTI LE IRON1 1 D.90 DEG. ELBOW NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WEIGHT A B EACH PIECE 1X1/2 DB90031 500 1.26 1.36 0.44 1X3/4 I DB90032 500 1.37 1.45 1 0.52 I 1/4X1/2 DB90041 500 1.34 1.53 0.64 I 1/4X3/4 DB90042 500 1.45 1.62 0.72 I 1/4X1 0B90043 500 1.58 1.67 0.75 I 1/2X1 DB90053 500 1.65 1.80 0.92 I 1/2X1 1/4 DB90054 500 1.82 1.88 1.08 2X1/2 DB90061 500 1.49 1 1.88 1.08 2X3/4 DB90062 500 1.60 1.97 1.24 2X1 DB90063 500 1.73 2.02 1.40 2X1 1/4 DB90064 500 1.90 2.10 1.52 2X1 1/2 DB90065 500 2.02 2.16 1.65 LJ• DUCTILE IRON COUPLING NOMINAL I SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. IDIMENSION I WEIGHT' EACH PIECE A I DCL033 500 1.67 0.40 11/4 DCLO44 500 1.93 0.57 1 1/2 DCL055 500 1 2.15 0.75 2 DCL066 500 1 2.53 1.15 DUCTILE I 45 DEG. I NOMINAL' SIZE (INCH) ITEM ' CODE MAX. WORKING P.S.I. IDIMENSIONS WEIGHT I - A B EACH PIECE I DB45033 500 1.12 1.12 0.46 11/4 DB45044 500 1.29 1.29 0.73 1 1/2 DB45055 500 1.43 1.43 0.92 2 D845066 500 1.68 1 1.68 1.50 DUCTILE IRONiSTRAIGHT TEE I NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. II)IMENSI0NSI WEIGHT - A - B EACH PIECE I DT333 500 1.50 1.50 0.85 11/4 DT444 500 1.75 1.75 1.22 11/2 DT555 500 1.94 1.94 1.55 2 DT666 500 1 2.25 1 2.25 1 2.45 I D UCTILE IRONIRED. COU J U [c NOMINAL SIZE (INCH) ITEM CODE # MAX. WORKING P.S.I. DIMENSION WEIGHT EACH PIECE A IXI/2 DRC03I 500 1.69 0.39 1X3/4 DRC032 500 1.69 0.53 S STAR®PIPE PRODUCTS D.I. THREADED FITTINGS LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 Ductile iron threaded fittings are UL, ULC listed and factory mutual approved for 500 psi service. Ductile iron per ASTM A 536 grade 65-45-12. Dimensions conform to ANSI B16.3 class 150. Threads are NPT perANSI/ASME 131.20.1. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittingd should be tightened theree turns beyond hand tight, but no more than four turns. Page 21 El SIO 11!wqs Isenbei S83!AJ9S uO!jO8OJd aiij J0j 03AOddV 031911 O3ISI1 <*> 699 IV SONinu aavii ia £LdBUOmJMMJV1S WO SP I. 009 900d30 090 £tl. 009 SOOd3O ZII I. CPO 9fl. 009 POOd3 P/I I. CO 91.1. 009 COOdOa1. JOJId V H3V J.HDBM INOISrSIPlOI TSd 9NIOM -XVW # 3003 IN3J.l (HONI) ]ZIS 1VNIINON ii.iINONI 3monaNON 7iIc,t P14III ,IIJ4!J! ' - t4iI:t 44i4'P'I'J-4-' 71l47Il uI'i41'1 'I-IiJh '4D:u47i. 7j•l(_ 71'111'I'I'I i*ir I'1 x,I iin • t1'/ IVNIWONI 931 ONI3flO3J NOII iiiona o1. oz Efl. 009 toxa 1.XZ 9P1. 09' l. 991. 009 £SOXO 1.XIl. I. LII. 1.91 991 009 £PDXO IXPII. 1. 967 S 009 990X0 061 P61 1761. 009 ssoxa ZII 1. 091. I 91.1. 91.1. 009 voxa P11 1 860 091. OW l. 009 £COXO 1. 33Id HOV] 8 V - - lSd DNI)IdOM XVVJ # 3003 VJ3II (HoNI) 3ZIS 1VNILØJON .LHOBM SNOISN3LNIO IIs}Es] NOUI 311ionaI IWO IflO in PE0 980 S9HSfl80 in 1X LO .LflO orz PCO 990 P9HSfl80 P11. 1X 990 NI 961. WO 880 C9HSfl80 1X OCO mO 007 WO £90 P9HSfl80 P/I. 1XII I PPO .LflO 0O 1.00 £90 £SHSfl80 I I.X/1 I. 9O I .LflO 91.1. 90 090 £t'HSfl8a IXP/I. 1. L10 .LflO P1. I 9tO I 91.0 ZCHsnea P/EXt. mO P1. 1CHSfl80 1A1S 0 /l.X1 H3V !tos.ro 0O3 VJ311 HONI MIS 1VNIVION SNOISN]VII0 )]II:Ff.I:u 5IIFI - dft FireLock® Fittings FireLocke products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees are a CAD-developed, hydrodynamic design that has a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Style 005 and Style 009 FireLock couplings. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Fitting Coating: Orange enamel. Optional: Hot dipped galvanized. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved www.victaulic.com vICTAuLIc IS REGISTERED TRADEMARK OF vicTAuLic COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV H \4taukcr 10.031 0 IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.03 0 FireLock® Fittings DIMENSIONS CtoE . C to I Cto'" it NO. 001 NO. 003 NO. 002 NO. 006 01 No. I,. 90' Elbow 45'Elbow Straight Tee Weight Each NEW kg 11/4 1.660 . 0.8 0.3 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 - 70 - 11 - 22 0.3 21/2 2.875 1' 3.00 3.1 2.25 2.2 3.00 + 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 -F -t -- - '- ----- -4. . f 76.1 mm 3.000 3.00 3.30 2.25 2.4 - - - - 76.1 76 1.5 57 1.1 3 3.500 I 3.38 1 4.0 2.50 ' 3.1 3.38 5.3 0.88 ± 1.2 80 88.9 I 86 1.8 64 1.4 86 2.4 22 0.5 4. 4.250 4.00 5.7 3.00 5.1 4.00 7.5 mm - - 108.0 102 - 2.6 - 76 . 102 3.4 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 ±---- •_ - .t ------• -- ---t- - .4. 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1,00 . 4,1 125 141.3 124 5.7 83 3.8 124 ' 7.1 25 1.9 + 6.250 5.50 12.6 3.50 9.2 5.50 17.9 159mm - 158.8 140 5.7 89 4.2 140 8.0 - 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 I 25 2.7 .4. -----t - - -- 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 [i www.victaulic.com VICTALILIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. IO.03_2 4tauiicr REVH IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.03 is FireLock® Fittings FLOW DATA 1 1A 1.660 1.5 1 0.8 3.7 1.5 32 - 42.4 0.5 0.2 1.1 0.5 1 1/2 1.900 2.2 1 1.1 5.5 2.2 40 48.3 0.7 i 0.3 1.7 0.7 - ----4- -- 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 21/2 2.875 4.3 2.2 10,8 4.3 65 73.0-- 1.3 0.7 3.3 1.3 , , , 76.1 mm 3.000 4.5 2.3 11.0 45 - 4 - 07 ' 34 1 1 3 3.500 5.0 2.6 13,0 5.0 80 , 88.9 4- 1.5 0.8 - - ± - - , 1.5 mm 4.250 6.4 3.2 15.3 I 6.4 108.0 2.0 0.9 4.7 I 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21,0 8.5 125 141.3 2.6 1.3 6.4 2.6 -- --- 4- ± mm 6.250 9.4 . 4.9 25.0 9.6 158.8 I 2.9 1.5 7.6 2.9 6 '1 6625 i 5D -+10.0 25.0 150 168.3 3.0 1.5 7.6 3.0 8 F- -1 8.625 - 13.0 --4- - - 5.0 - 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 C The flow data listed is based upon the pressure drop of Schedule 40 pipe www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF vicTAuLic COMPANY. 0 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REVH \4taulicr 1O.03_3 GENERAL NOTES NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009 and Style 009V couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V couplings. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. III II 1111111111 1111111111 11111111 III WCAS-7MX2JY - For complete contact information, visit www.victaulic.com 10.03 1539 REV H UPDATED 1/2009 ictaulic VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 vIcTAuuc COMPANY. ALL RIGHTS RESERVED. 10.03 FireLock® Rigid Coupling i s LPC ee,, O a,,d VdS tes on page 4 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS 40 STYLE 005 WITH VIC-PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) FireLock® Style 005 rigid coupling has a unique, patented angle-pad design which allows the housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. Support and hanging requirements correspond to NFPA 13 Sprinkler Systems. Angle-pad design permits assembly by removing one nut/bolt and swinging the housing over the gasket. This reduces components to handle during assembly. Style 005 FireLock coupling are designed and recommended for use ONLY on fire protection systems. VicPlusTM Gasket System: In North America, Victaulic® offers a gasket system which requires no field lubrication on wet pipe systems that are hydrostatically tested. The VicPIusTM System (patented) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over- lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (1-100) for supplemental lubrication requirements and dry pipe fire protection system notes. PA I LN I LI) (cPIus Caslaset Systrn a.2 jUIThll LISTING/APPROVALS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. FM approved for service in 1 ½ - 4" pipe. UL Listed for service up to 4 pipe only. @ UL Listed for service up to 3 only. JOB/OWNER System No. Location CONTRACTOR ENGINEER Submitted By Spec Sect Approved Pa ra Date__________________________________ www.victaulic.com - vicuic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. l _U1 iic REVI 10.021 IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.02 FireLock® Rigid Coupling STYLE 005 WITH VICPLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) DIMENSIONS S ¼ 1.660 j 350 j 755 0.05 2-/8x21/4 2.75 4.50 1.88 I 1.2 32 42.4 I 2413 3370 I 1.2 70 - 114 148 --4- _188- 4-.75 05 - -1.2 1 ½ 1.900 350 990 005 2 - 1/8 x 214 3.00 40 I 48.3 I 2413 4415 12 76 121 I 148 05 - 4. -- - - - 3.50 2 2.375 350 I 1550 0.07 2- /i2 x'/i 525 1.88 1.6 50 2½ 60.3 2413 I 2.875 350 6900 I 2270 I 1.7 0.07 89 4.00 133 148 5.75 188 0.7 1.9 -. 2 -/sx 2½ 65 * 73.0 2413 10110 I 17 - - 102 146 148 - .09 4.13 - 3.000 350 2475 0.07 76.1 mm I 2 ¼x2½ 5.75 146! 1.88 1.9 3 76.1 2413 3.500 350 11010 3365 1.7 0.07 105 6.13 148 1.88 - 0.9 2.1 4.63 80 88.9 2413 .1----- - 14985 I 1.7 2 - /iX 21/2 118 156 148 - 1.0 4 4 350 5565 I 2 - %.500 0.16 x 2½-- . 5.75 7.25 I 2.13 3.1 100 114.3 2413 24770 4------- 4.1 146 184 54 1.4 t' 108.0mm I 4.250 300 4255 016 . - /rx2½ 5.63 7.25 2.13 3.1 108.0 - 2068 18940 4.1 143 184 54 - 1.4 - -- - 1 - 5 5.563 300 7290 0.16 2-½x3 6.88 9.00 2.13 4.5 125 141.3 2068 I 5.250 300 32445 4.1 6495 0.16 -- 175 229 54 2.0 6.63 9.00 2.13 4.5 133.0 mm 2-½X2'/4 133.0 2068 28900 4.1 168 229 54 - 20 - - 139.7 mm I 5500 300 i 139.7 I 2068 ' 7125 0.16 31715 4.1 2- 1/2 x 2¼ 6.88 I 175 9.00 229 2.13 54 4.8 2.2 8.00 1000 I 2.13 fLO -t 6 6.625j 300 t 0 1 2-½x3 150 168.3 2068 _46020 4.1 203 25453 - 2.3 159.0 mm 6.250 300 9200 0.16 2-½x23A 7.63 1000 213 55 159.0 2068 I_40955 4.1 - - 194 254J 54 - 2.5 165.1 mm 6 .500 300 9955 I 0.16 2 -½ x 3 8.15 10.00 I 2.13 5.5 165.1 'J 2068 44295 4.1 207 254 _54 2.5 8 8.625 300 t 17525 0.19 2 -5/a X 4¼ 10.50 13.14 2.63 11.3 200 219.1 2068 I 78000 4. 8 267 334 67 5.1 J.L iIt li&Ih - Rated for wet and dry sprinkler systems at 350 psi/2413kPa for 114_ 4/32 - 100mm sizes and 300 psi /2068 kPa for 4'/4 - 87108 - 200 mm sizes; Schedule 10 roll grooved or Schedule 40 cut or roll grooved steel pipe. Style 005 is rigid and does not accommodate expansion, contraction or angular deflection. Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for perfor- mance another pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. t The allowable pipe separation dimension shown is for system layout purposes only. Style 005 couplings are con- sidered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. § Style 005 couplings are VdS and LPC Approved to 12 Bar/175 psi. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. 10.022 JtauIicr REVI IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.02 FireLock® Rigid Coupling . STYLE 005 WITH VIC-PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel (North America); red enamel (Europe) Optional: Hot dipped galvanized Gasket: Grade "E" EPDM - Type A Vic-PIus°' Gasket System t (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Vic-Plu? Gasket System, requiring no field lubrication for most installation conditions. Grade L" Silicone Recommended for dry heat, air without hydrocarbons to +350°F and certain chemical services. For dry services, Victaulic continues to recommend the use of Grade E" Type A FlushSeal® Gasket. Contact Victaulic for details. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. A Standard gasket and FlushSeal gasket approved for dry pipe systems to —40°F/-40°C. Based on "typical" pipe surface conditions, supplemental lubricant is recommended for services installed below 0°F/-18°C and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water. Supplemental lubrication may also be required on pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams. Victaulic continues to recommend the use of FlushSeal gaskets for dry services. www.victaulic.com Ai_C_t8_UhC~ VIcTAULIc ISA REGISTERED TRADEMARK OF vicTAuLic COMPANY, © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV 1 10.60. 3 r FireLock® Rigid Coupling . STYLE 005 WITH VIC-PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) GENERAL NOTES WARNING: Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. • II lItIIlillIIlIIIIIIlUIIIII II IlIlI III III WCAS-697KR4 For complete contact information, visit www.victaulic.com 10.02 1538 REV I UPDATED 9/2006 ictaulice vicTAuLic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2006 VICTAULIc COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. 10.02 Incorporates 1/2-1710-25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products UL/ULC Listed, LPCB, VdS/FM Approved for .• branch connections on wet and dry systems Style 922 FireLock Outlet-Ts are not approved for cross configurations Pressure rated up to 300 psi/2065 kPa and rated up to 230 psi/16 Bar at the ambient temperatures typical for fire protection systems Sizes from 1'/4x½'/32x15mm through 2½x 1/76.1 x25 mm S Hole Cut Piping System FireLock Outlet-I STYLE 922 For Complete Information Request Publication 10.52 1'/~ X ½ 1M 1.30 I 1.83 1.10 3.87 2.56 I 1.0 32 15 30.2 33.0 446.5 27.9 98.3 j 65.0 0.45 3/4 1 3A 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 I 46.5 27.9 98.3 65.0 I 0.50 -- 1 1 3A6 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 13A6 38.6 I 1.42 55.4 1.95 27.9 1.22 98.3 -- 4.08 . 1 65.0 --. 2.56 I I 0.54 1.2 1½ 1/2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 j 054 3/4 1 'A 1.40 1.95 1.22 4.08 i 2.56 1.2 20 30.2 I 35.6 49.5 31.0 103.6 I 65.0 I 0.54 -I- .- t --.- - 1 1 546 1.64 2.30 1.22 4.08 1 2.56 1.3 25 30.2 1 546 I 41.7 I 1.66 1 58.4 2.19 I -. 31.0 -- 1.46 103.6 4.60 4 65.0 2.56 . 0.59 1.3 2 1h 50 15 30.2 42.2 I 55.6 37.1 116.8 - 65.0 - .0.59 3/4 1546 I 1.64 2.19 4 1.46 4.60 1 2.56 1 1.4 20 30.2 I 41.7 55.6 37.1. + 116.8 65.0 t 0.64 1 1 51 I 1.88 + 6 2.54 1.46 4.60 2.56 1.5 25 30.2 1 I 47.8 t- 1.91 + 64.5 2.44 37.1 1.71 116.8 5.40 -1- 65.0 - 2.56 -6 -- 0.68 1.6 2½ ½ 65 15 30.2 48.5 I 62.0 - 43.4 137.2 65.0 0.73 'U- 3/4 1 54 I 1.89 2.44 1.71 5.40 2.56 1.6 2030.2j48.0 414 I137.2 65fl 0.73 1 13A+ 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 1546 -4--- 54.1 -- I 1.91 I -4--------- 70.9 2.44 --4-'- I 43.4 ---+ 1.71 I 137.2 --'- I 5.50 ± - 65.0 -- 2.56 I + , 0.73 1.6 76.1mm X ½ 15 30.2 I 48.5 62.0 43.4 I 139.7 65.0 0.73 - 3/4 1 1,16 1.89 2.44 1.71 I 5.50 2.56 1.6 20 30.2 48.0 62.0 - 43.4 139.7 65.0 0.73 1 1,16 2.13 2,79 1,71 5.50 1 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. use of male threaded products with special features, such as probes, dry pendent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). v 614- I i? TYPICAL FOR ALL SIZES C 5-9 X /22-te"'e WWW.VICTAULIC.COM G-105 FIRE PROTECTION CATALOG All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 38 Fire Protection Solutions B-Line by ET.H Pipe Clamps . Fig. 24 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe** ØTOL.co Double Fastener Strap Side Mounted (B-Line B3183) C u. US Size Range: 3/4"(20mm) thru 2" (50mm) CPVC pipe .' LISTED Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom - - - of a beam. Approvals: Underwriters Laboratories Listed in the USA (UL) and zl Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.912mm) steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of - - NFPA 13, 13R and 13D. Features: Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the , two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with I a hex socket attachment be used as installation tools. No impact , tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a - pilot hole in wood is required. B Finish: Pre-Galvanized B ... Order By: Figure number and pipe size A Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. ** With reduced spacing, consult factory. 0 Pipe CPVC Size A B C Max. Hanger Fastener Hex Approx. Spacing Head Size Wt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m) in. (mm) Lbs. (kg) 24-/4 3/4" (20) 2/16" (58.7) 1/32" (27.8) 1/16" (30.2) 51/2 (1.67) /16" (7.9) 9 (4.1) 24-1 1" (25) 2/8" (66.7) 1/16' (33.3) 1/16" (30.2) 6 (1.83) /16" (7.9) 9 (4.1) 24_1114 11/4" (32) 3" (76.2) 11/2" (38.1) 13/16" (30.2) 61/2 (1.98) /16" (7.9) 11 15.01 24-11I2 11/2" (40) 31/4" (82.5) 1/8" (42.3) 1/16" (30.2) 7 (2.13) /16" (7.9) 12 (5.4) 24-2 2" (50) 311/16" (93.7) 127/32" (43.6) 1/16" (30.2) 8 (2.44) /16" (7.9) 15 (6.8) Fig. 25 - Surge Restrainer Size Range: - One size fits 3/4 (20mm) thru 2 (40mm) pipe. - USTED 3 Material: - Pre-Galvanized Steel . Function: - Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is / ,/ / easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 ... edition 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUL). Finish: Pre-Galvanized . -. 0 Order By: Figure number and band hanger, size from 3/4" (20mm) thru 2" (40mm). Patent #5,344,108 Set Screw and Locknut Included Beam Clamps S Fig. 65 - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening Fig. 65XT - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening (bottom of page) ®TOLCO 9 & LISTED Size Range: Fig. 65 - 1/2'_13 rod sizes, and /8'-11 rod sizes Fig. 65XT - /8"-16 rod size (see below( Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 3/4" 119.0mml. Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, /'-16 rod will support 1/2" (15mm) thru 4" (lOOmm) pipe 1/2'..13 rod will support thru 8" (200mm) pipe Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Figure number and finish Fig. 65 Patent #4,570,885 Part Rod Size B C D E No. A in. (mm) in. (mm) in. (mm) in. (mm) 65-1/2 1/2"_13 11/2" (38.1) 3/4" (19.0) 1" (25.4) /16" 114.31 65-I8 /8"-11 11/2" (38.1) 3/4" (19.0) 1" (25.4) /16" (14.3) Part F Approx. Wt./100 - - - - - No. in. (mm) Lbs. (kg) 65_1/2 11/4" (31.7) 55 (24.9) 65-Ie 11/4" (31.7) 55 (24.9) - Fig. 65X1-3/8 - Beam Clamp Feature: Extruded holes allows for more thread engagement of threaded rod and set screw. Weight: Approx. Wt./100 - 28.0 Lbs. (12.7kg) Finish: Plain or Electro-Ga Ivan ized Order By: Figure number and finish Approvals: Underwriters Laboratories Listed (cULus) and FM Approved (FM) for up to 4" (100mm) pipe. Designed to meet or exceed requirements of FM DS 2-0. 3/8" (19.0) Set Screw and Locknut Included 13/8" (34$) (22.2) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions i by S Beam Clamps Fig. 69R - Retrofit Capable Beam Clamp Retaining Strap Size Range: I8"-16 & 1/2'13 rod 4" (101,6mm) thru 16" (406.4mm) lengths Note: longer lengths are available consult factory Material: Pre-Galvanized Steel Function: To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13. Features: Beveled locking slot* is precisely formed to align with the threaded section of a hanger rod or set screw and engage the unit securely. May be used as shown in Section "A-A" or inverted. Allows easy installation for new construction or retrofit applications. Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore the beveled locking slot of the Fig. 69R will provide a secure reliable installation. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam Clamp. Finish: Pre-Galvanized Order By: Figure number, length, and finish. Note: Minimum return on strap is 1" (25.4mm) For Use With: Any B-Line or TOLCO beam clamp. * Patent #5,947,424 Slot Width Length Part No. in. (mm) 69R-3/8-L /16" (30.1) Specify 69R-1/2-L /16" (30.1) Specify ®TQLcO Component of State of C us California OSHPD Approved Seismic Restraints System USM A-A All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 17 B-Line by Ei.N Threaded Accessories ØTOLCc 10 B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) B32051 - Threaded Rod (right & left hand threads) Size Range: I816 thru 3-4 rod Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. Specify Length Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature: 750 OF (399°C) TL Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and A materials. Thread Size Order By: Figure number, rod size, length and finish 00 Standard Design Load Thread Size Thread Length TL 650°F (343°C) 750°F (399°C) Part No. A in. (mm) Lbs. NN) Lbs. (kN) B3205-318 x L 3/8 -16 21/2 (63.5) 730 13.251 572 12.541 B3205-1I2 X L 1/2°13 21/2 (63.5) 1350 (6.00) 1057 (4.70) B3205-5/a x L /8-11 21/2 (63.5) 2160 (9.61) 1692 17.521 B3205-3/4 x '/4-10 3° (76.2) 3230 (14.37) 2530 (11.25) . B3205-1/8 x L /8-9 31/2 (88.9) 4480 (19.93) 3508 (15.60) For larger sizes consult full line pipe hanger catalog. TL ATR - All Threaded Rod (TOLCO Fig. 99 & Fig. 100) Size Range: /8"-16 thru 11/26 rod in 10 (3.05m) lengths Material: Steel Maximum Temperature: 750°F (399°C) Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Note: Fig. 99 is cut to length all threaded rod. Fig. 100 is full length. Part No. Threads Recommended Load Approx. Wt./100 Ft. & Size Per Inch Lbs. (kN( Lbs. (kg) ATR '/" x 1' 20 240 (1.07) 12 (5.44) ATR 3/g" x '1' 16 730 (3.24) 29 113.151 ATR 1/2" x 13 1350 (6.00) 53 (24.04) ATR 5/8" x '1' 11 2160 (9.60) 89 (40.37) ATR 3/4" x 10 3230 (14.37) 123 (55.79) ATR 7/g" x L' 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog. B- All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Line by ET.N 94 Fire Protection Solutions Fig. 200-1I2. 200-/ Fig. 200-21/2 to 200-8 Fig. 200 Fig. 200S All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 21 B-Line by EI4V Pipe Hangers ØTOLCO c@ us USTED Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B3170NF) is Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B311ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B311ONFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2 " (15mm) thru 8" (200mm) pipe Material: Steel, Pie-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design - - keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. / A For hanger with non-captured nut order Fig. 200S. / 121/2" (65mm) thru 8" (200mm)1 Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. / Approvals: Underwriters Laboratories listed 11/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Fig. 200-110200-2 Conforms to Federal Specifications WIN-H-171 E & A-A-I 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) .- - Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of Fig. 200C Fig. 200F Pipe Size Rod Size A B Approx. Wtj100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2" (15) /811-16 31/8" (79.4) 2/8" (66.7) 11 (5.0) 200-I4 3/4" (20) /811-16 31/8' 179.41 21/2" (63.5) 11 (5.0) 200-1 1" (2$) /811-16 3/8" (85.7) 2/8" (66.7) 12 (5.5) 200-11I4 11/4" (321 /s"-16 33/4' (94.0) 2/8" (73.0) 13 15.91 200-11I2 11/2" (40) /8"-16 3/8" 198.41 21/8" (73.0) 14 (6.4) 200-2 (50) /8'-16 41/2" (114.3) (76.3) 15 (6.9) 200-21I2 21/2" (65) /811-16 5/8' (142.9) 41/8" 1104.71 27 (12.3) 200-3 3" (75) 3/11-16 5/8" (149.1) 4" (101.6) 29 (13.3) 200_3112 31/2" (90) /811-16 1/8' (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) /8"-16 1/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"..13 91/8" (231.8) 61/4" 1158.71 66 (30.2) 200-6 6" (150) 1/2"..13 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"13 131/8" (333.4) 8/i" (222.2) 136 (62.3) OPM USTED 11) y D t 4LA-1 thru 4LA-4 Seismic Bracing S TOLCO Fig. 4LA - In-Line Sway Brace Attachment (UL Listed) Size Range: 1 (25mm) through 8" (200mm) IPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. Approvals: For FM Approval information refer to FM Approved page 77. Underwriters Laboratories Listed in the USA and Canada (cUlus). Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to our Seismic Engineering Guidelines, OPM-0052-1 3. Installation Instructions: Fig. 4LA can be used as the system attachment component of a longitudinal or lateral brace assembly. It is intended to be combined with the "bracing member and TOLCO transitional attachment and structural attachment to form a complete bracing assembly. For fire sprinkler applications NFPA 13 guidelines should be followed. To Install: Place the Fig. 4LA pipe clamp component over the pipe to be braced and tighten down the break-off nuts until the hex head portion breaks off to verify correct installation torque. Next engage brace member (pipe or strut) with jaw component and tighten break-off head bolt until the hex head breaks off to verify correct installation torque. Pivot jaw for correct angle and attach to structure using TOLCO brand transitional attachment and structural attachment. Finish: Plain or Electro-Galvanized. Contact customer service for alternative finishes and materials. Order By: Figure number, pipe size and finish. Fig.. 4LA Brace Fig. 980 Fig. 980 Brace 0 ig. 4LA 4LA-6 thru 4LA-12 Pipe UL Max. Rec. load Approx. Part Size A C D Bolt Size Longitudinal Lateral W000 No. in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kN) lbs. (kg) 4LA-1 1" (25) 319/32" (91.2) 15/16" (33.5) 15/16" (33.5) 3/8 -16 1000 (4.45) NA (NA) 119 (54.0) 4LA-1114 11/4" (32) 329/32" (99.3) 13/8' (35.3) 13/8' (35.3) 3/8 -16 1000 (4.45) NA (NA) 123 (55.8) 41.A-11/2 11/2" (40) 45/32" (105.7) 11/2" (38.5) 11/2" (38.5) 3/8 -16 1000 (4.45) NA (NA) 127 (57.6) 4.2 2" (50) 511/32" (135.6) 21/32" (51.9) 21/16" (51.9) 3/8 -16 1000 (4.45) NA (NA) 142 (64.4) 4LA-21/2 21/2" (65) 527/32" (148.7) 25/16" (58.5) 25/16" (58.5) 3/8 -16 1000 (4.45) NA (NA) 173 (78.5) 4LA-3 3" (80) 61/2" (164.9) 25/8" (66.6) 2/8" (66.6) 3/8 -16 1000 (4.45) 1000 (4.45) 187 (84.8) 4LA-31/2 31/2" (90) 7.407" (188.1) 27/8" (73.1) 2/8" (13.1) /8"-16 1000 (4.45) 1000 (4.45) 198 (89.8) 4LA-4 4" )100) 713/32" (190.8) 31/8" (79.5) 31/8' (79.5) 3/8 -16 1000 (4.45) 1000 (4.45) 209 (94.8) 4LA-6 6" (150) 105/8" (269.9) 49/16" (115.9) 49/16" (115.9) 1/2"13 1600 (7.12) 1600 (7.12) 521 (236.3) 4LA-8 8" (200) 1213/16" (325.5) 59/16" (143.7) 521/32" (143.7) 1/2"_13 2015 (7.12) 2015 (7.12) 629 (285.3) 4LA_10* 10" (250) 161/2" (419.1) 71/4" (184.2) 71/4" (184.2) 1/2"_13 NA (NA) NA (NA) 1320 (598.7) 4LA_12* 12" (300) 181/2" (469.9) 81/4" (209.6) 81/4" (209.6) 1/2"_13 NA (NA) NA (NA) 1496 (678.6) * FM Approved but not UL Listed. Eaton's B-Line series seismic bracing components are designed to be compatible . only with other B-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton, except that, in addition to the other exclusions from Eaton B-Line Division warranty. Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 76 B-Line series Fire Protection Solutions ØTOLCO c®us USTED K Set Bolt Included Mounting Hardware Is Not Included All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 66 Fire Protection Solutions B-Line by 1[.N S Seismic Bracing Fig. 980 - Universal Swivel Sway Brace Attachment - /8" to 3/4" Size Range: One size fits bracing pipe 1 (25mm) thru 2" (50mm), B-Line 12 gauge (2.6mm) channel, and all structural steel up to 1/4' (31.7mm) thick. Material: Steel Function: Multi-functional attachment to structure or braced pipe fitting Features: This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation: Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO "braced pipe' attachment, Fig. 1000, 1001, 2002, 4L, 4A or approved attachment to pipe to form a complete bracing assembly. NFPA 13 guidelines should be followed. To Install: Place the Fig. 980 onto the "bracing pipe". Tighten the set bolt until the head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals: —Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). For FM Approval information refer to page 67. Note: Fig. 980 Swivel Attachment and Fig. 1001, 1000, 2002, 4A or approved attachment to pipe that make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters Laboratories and the National Fire Protection Association (NFPA) Finish: Plain, Electro-Galvanized or Stainless Steel. Contact B-Line for alternative finishes. Order By: Figure number and finish. Pat. #6,273,372, Pat. #6,517,030, Pat. #6,953,174, Pat. #6,708,930, Pat. #7,191,987, Pat. #7,441,730, Pat. #7,669,806 Fig. 980 Fig. 4L Longitudinal Brace Part Mtg. Hdw. Mounting Hole Max. Design Approx. Number Size A B D Load (cULus) W000 in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) 980-I8 /8" (9.5) 51/4" 1133.3) 1I8" (47.6) 13/32" (10.3) 2015 (8.96) 149 (67.6) 980_1/2 * 1/2" 112.71 51/4" (133.3) 1/8" (47.6) 17/32" 113.51 2015 (8.96) 148 (67.11 980-I8 5/8" (15.9) 51/4" (133.3) 1/8" (47.6) 11/16" (17.5) 2015 (8.96) 147 (66.7) 980-/4 3/4" (19.0) 51/4" (133.3) 1/8" (47.6) 13/16" (20.5) 2015 (8.96) 146 (66.2) Standard size Important! - For load information when using Fig. 980 with pre-installed or post-installed concrete anchors in compliance with NFPA 13 (2016) or ASCE 7-10, including prying factors, see load tables on pages ALl thru AU1. Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. ®TOLCD C® US USTED All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Revised 51912014 70 Fire Protection Solutions B-Line by T4lJ Seismic Bracing . Fig. 1001 - Sway Brace Attachment Size Range: Pipe size to be braced: 1" 25mm) thru 8 (200mm) IFS. Pipe size used for bracing: 1" (25mm) and 11/4" (32mm) Schedule 40 IFS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features: Can be used to brace schedules 7 through 40 IFS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note: Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set bolts until heads bottom out. A minimum of 1" (25mm) pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). For FM Approval information refer to page 71. Finish: Plain or Electro-Ga Ivan ized. Contact B-Line for alternative finishes and materials. Order By: Order by figure number, pipe size to be braced, followed by pipe size used for bracing (V (25mm) or 11/4 (32mm)), and finish. Important Note: Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure 40 performance, the UL Listing requires that Fig. 1001 must be used only with other TOLCO bracing products. Pipe Part Number & Approx. WtJ100 Design Load - Lbs. Size 1" (4nimI Brace Pipe 11/4" (32mm) Brace Pipe For Brace Pipe Size 1" I1'I4" Sch.1 Sch.10 Sch.40 in. (mm) Lbs. (kg) Lbs. (kg) 1 'I11 /4" 1"I11I4" (25) 1001-1 X 100.0 (45.3) 1001-1 X 11/4 118.0 (53.5) --I-- 1000 /1000 1000/1000 11/4" (32) 1001 -11/4 X 100.0 (45.3) 1001 -11/4 X 11/4 114.0 (51.7) 1000/1000 1000/1000 1000/1000 11/2" (40) 1001_11/2 X 100.0 (45.3) 1001_11/2 X 11/4 115.0 (52.1) 1000/1000 1500/1500 1500/1500 (50) 1001-2 X 108.0 (49.0) 1001-2 X 11/4 121.0 (54.8) 1000/1000 2015/2015 2015 /2015 21/2" (65) 1001-21/2 X 1 138.6 (62.8) 1001-21/2 X 11/4 160.4 (72.7) 1600/1600 2015 /2765 2015/2765 (80) 1001-3 X 147.2 (66.7) 1001-3 X 11/4 168.7 (76,5) 1600/1600 2015/2765 2015/2765 (100) 1001-4 X 160.9 (73.0) 10014 X 11/4 182.4 (82.7) 1600 /1600 2015/2765 2015/2765 6" (150) J 1001-6X 1 190.0 (86.2) 1001-6X 11/4 211.4 (95.9) 1600/1600 2015/2765 2015/2765 8" (200) 1001-8 X 217.4 (98.6) 1001-8 X 11/4 238.8 (108.3) 1 1600/1600 2015/2765 2015/2765 SAMMYS® FOR WOOD No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. &th o do demc.stm5on www.itwbuildex.comj 1/4 8002957 GST 100 1/4 210 (7/16"OSB) 25 125 - 1/4 8003957 GST 200 1/4 x 2 1760 (Fir) 25 125 3/8' 8007957 GST 10 1/4 x 1 300 25 125 3/8 8008957 GST 20 1/4x 2 1760 (Fir) 850 1475 25 125 318" 8068925 GST 20-SS 1/4 x 2 1760 (Fir) 850 25 125 #14 Black 3/8 8009925 GST2S-380 3/8x21/2 2113 (Fir) 1500 25 - 125 Nut Driver /3? 3/8 8010957 GST 30 1/4x3" 2060 (Fir) 1500 1475 25 125 Pal #8113910 3/8 - 8069925 GST 30-SS 1/4x3 - 2060 (Fir) - - 25 125 I 1/2 8013925 GST 2 1/4 x 2 1760 (Fir) 25 125 1/2 8015925 GST3 1/4x3" 2275 (Fir) - 25 125 #14 SW Red Nut Driver Pail #8114910 - wu,FAcruvEuu.uA SPECIAL NUT DRIVER SYSTEM The nut drivers were designed with a unique spin-off feature which provides a taut and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. #14 Black - Nut Driver - 3/8 8139957 SH-GST2O 1/4x2" 1257 (Fir) Pan # 8113910 1903 Dim. Lumber 3/8k 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1406 © 45°otf vertical Dim. Lumber 903 Dim. Lumber j 1/2" 8303957 SH-GST/CST 2.0 5/16 x 1-3/4" 1406 @ 45"off vertical Dim. Lumber * May require pre-drilling; consuft joist manufacturer. #14 SH Orange Nut Driver Part #8273910 1500 850 @5" 25 125 25 125 LI "No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. Not less than 2 nominal width ___________________________ (1-1/2") opts 3-1/2" pipe; not less than 3 (2.1/2") nominal width 4'& 5 pipe Floor Joist I, AV Minimum 2-1/2" from bottom for branch lines. Minimum 3" from bot- tom for main lines. Exception: This requirement shall not apply to 2 or thicker nailing strips resting on top of steel beams. .iilllIIll! Watch a t4deo demoasiretion al wwwitwbuildex.comJ 1/4" 8019957 . 1 a 3/8" 3/8" 8020957 8021957 I 3/8" 8073925 3/8" 8022925 #14 SW Red U - 3/8" - - 8023925 Nut Driver Part #8114910 * May require pro-drilling; consult joist manufacturer. SWG 200 1/4 x 2 1725 (Fir) 25 125 SWG 10 1/4 xl 622 (Fir) 300 25 125 SWG 20 1/4 x 2" 1725 (Fir) 1050 25 125 SWG 20-SS 1/4 x 2" 1725 (Fir) 850 25 125 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 SWG30 1/4 x 3" 1884 (Fir) - 25 125 a%qMAXOwGIEW Eliminates distortion of threaded rod. Accommodates up to 3%" x 12 pitch roof. "Allows 17° deflection from vertical. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. No. 232 S CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM a SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Pratt & Whitney - Carlsbad SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 5940 Darwin Court CITY: Carlsbad PHONE: (858) 444-2000 FAX NUMBER: (858) 444-2056 Largest Building (ft.2): 59,320 Sprinkled? Yes Construction Type: IlIB SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): South end of Darwin Court TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 132 PSI Hydrant Number (if applicable): H61246&H61245 Elevation of test: 245 Feet Main Size: 8 INCH Pressure Zone: 550 Feet bate/lime of Test: Pitot Tube Reading: PSI Corresponding Flow: GPM Total Flow: 2,300 (split) GPM Residual Pressure 96 PSI At peak demand , this water system is capable of providing a fire flow discharge at 20 psi in the vicinity of the fire in excess of 8,000 gpm. However, this exceeds the City's maximum velocity criteria of 10 fps. Therefore, the maximum available fire flow at this location that meets both the maximum velocity and minimum pressure criteria is 2,300 gpm, split between the two hydrants noted. The fire flow required based on building square footage and construction type is no more than 5,250 gpm for 4 hours, before any reduction is applied for sprinklers. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name: Jennifer _R.Mael.P.E. Eng. Lic. No. (if applicable): C69606 Signature: - Title/Org: P '_ManaVer Date: 08/07/2020 . . . Legend 11 w—Hydrant Pipe ZONE 550 Fire Flow Test Location H61245 c 2; COZ 8' Project Site Fire Flow Test Location H61246 #232 Pratt & Whitney (5940 Darwin Court) - Fire Flow Analysis Hydraulic calculations using HydraCALC COSCO FIRE PROTECTION 4990 GREENCRAIG LANE SAN DIEGO, CA 92123 858-444-2000 Job Name : Pratt & Whitney Carlsbad TI - Pre Action Drawing : FP 202 Location : 5940 Darwin Court Remote Area : I Contract : 10.CA 5501 Data File : 10.CA_5501 Pratt & Whitney Carlsbad TI pre action.WXF Computer Programs by Hydratec Inc. Revision: 50.53.5 S S COSCO FIRE PROTECTION Page 1 Pratt & Whitney Carlsbad TI - Pre Action Date 8-12-2020 n HYDRAULIC CALCULATIONS for Project name: Pratt & Whitney Carlsbad TI - Pre Action Location: 5940 Darwin Court Drawing no: FP 202 Date: 8-12-2020 Design Remote area number: I Remote area location: Pre-Action Occupancy classification: B Density: .2 - Gpm/SqFt Area of application: 141 - SqFt Coverage per sprinkler: 130 - SqFt Type of sprinklers calculated: Pendent No. of sprinklers calculated: 2 In-rack demand: - GPM Hose streams: 250 - GPM Total water required (including hose streams): 302.607 -GPM Type of system: Pre-Action Volume of dry orpreaction system: 25.66 - Gal @ 50.1625-Psi S Water supply information Date: 8/7/2020 Location: 5940 Darwin Court Source: Mission Consulting Name of contractor: COSCO FIRE PROTECTION Address: 4990 GREENCRAIG LANE / I SAN DIEGO, CA 92123 Phone number: 858-444-2000 Name of designer: MJ Authority having jurisdiction: City of Carlsbad Notes: (Include peaking information or gridded systems here.) S Computer Programs by Hydratec Inc. Revision: 50.53.5 Water Sy Curve C 0 COSCO FIRE PROTECTION Page 2 Pratt & Whitney Carlsbad TI - Pre Action Date 8-12-2020 City Water Supply: Demand: Cl - Static Pressure : 118.8 Dl - Elevation : 9.528 C2 - Residual Pressure: 82.8 D2 - System Flow : 52.607 C2 - Residual Flow : 2300 D2 - System Pressure : 50.162 Hose ( Demand) : 250 D3 - System Demand : 302.607 Safety Margin : 67.793 150 140 -- 130 -- Cl I 2O : 110 E 100 S 90 C2 80 u° R6° 02 E5° 40 13 30 20 VD 10 300 600 900 1200 1500 1800 2100 2400 2700 FLOW( N"1.85) Computer Programs by Hydratec Inc., Revision: 50.53.5 Fittings do Summary 40 0 COSCO FIRE PROTECTION Page 3 Pratt & Whitney Carlsbad TI - Pre Action Date 8-12-2020 Fitting Legend Abbrev. Name 1/2 % 1 11/4 11/2 2 21/2 3 31/ 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 L NFPA 13 Long Turn Elbow 0.5 1 2 2 2 3 4 5 5 6 8 9 13 16 18 24 27 30 34 40 T NFPA I39O'FlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 V 90EllFirelock#001 0 0 0 0 0 3.5 4.3 5 0 6.8 8.5 10 13 4.5 5.1 0 0 0 0 0 Zfc Febco 856 Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.53.5 Pressure I Flow Summary - STANDARD COSCO FIRE PROTECTION Page 4 Pratt & Whitney Carlsbad TI - Pre Action Date 8-12-2020 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. P1 22.0 5.6 22.57 na 26.61 0.2 130 7.0 P2 22.0 5.6 21.56 na 26.0 0.2 130 7.0 Ml 26.0 24.84 na TOR 26.0 26.22 na BOR 16.0 33.35 na M2 26.75 31.4 na M3 26.75 33.9 na M4 26.75 33.98 na EBOR 2.0 44.7 na UG1 -3.0 46.87 na BF1 -3.0 46.87 na BF2 -3.0 51.46 na TEST 0.0 50.16 na 250.0 The maximum velocity is 9.88 and it occurs in the pipe between nodes P1 and Ml S Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams COSCO FIRE PROTECTION Page 5 Pratt & Whitney Carlsbad TI - Pre Action Date 8-12-2020 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 EIev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf P1 22 5.60 26.61 1 2E 2.855 6.500 100 22.574 to 1 3.568 6.423 -1.732 Ml 26 26.61 1.049 0.0 12.923 0.3091 3.995 Vel = 9.88 0.0 Ml 26.61 24.837 K Factor= 5.34 P2 22 5.60 26.00 1 2E 2.855 10.500 100 21.556 to 1 3.568 6.423 -1.732 Ml 26 26.0 1.049 0.0 16.923 0.2962 5.013 Vel = 9.65 0.0 Ml 26.00 24.837 K Factor= 5.22 Ml 26 52.61 1.5 E 2.855 7.333 100 24.837 to 0.0 2.855 0.0 TOR 26 52.61 1.61 0.0 10.188 0.1355 1.380 Vel = 8.29 TOR 26 0.0 1.5 E 2.855 10.000 100 26.217 to 1 5.71 10.706 4.331 BOR 16 52.61 1.61 EgI 2.141 20.706 0.1355 2.805 Vel = 8.29 BOR 16 0.0 1.5 1 8.0 12.000 120 33.353 to 2E 8.0 16.000 4.656 M2 26.750 52.61 1.61 0.0 28.000 0.0967 2.707 Vel = 8.29 M2 26.750 0.0 2 1 10.0 77.000 120 31.404 0.0 10.000 0.0 .to M3 26.750 52.61 2.067 0.0 87.000 0.0286 2.492 Vel = 5.03 M3 26.750 0.0 4 1 26.334 73.000 120 33.896 to 0.0 26.334 0.0 M4 26.750 52.61 4.26 0.0 99.334 0.0008 0.084 Vel = 1.18 M4 26.750 0.0 8 V 15.269 45.333 120 33.980 to 0.0 15.269 10.719 EBOR 2 52.61 8.249 0.0 60.602 0 0.002 Vel = 0.32 EBOR 2 0.0 8 2L 41.12 11.833 140 44.701 to 0.0 41.120 2.166 UG1 -3 52.61 8.27 0.0 52.953 0 0.001 Vel = 0.31 UGI -3 0.0 8 L 16.29 191.625 150 46.868 to 0.0 16.290 0.0 BFI -3 52.61 7.68 0.0 207.915 0 0.006 Vel = 0.36 BF1 -3 0.0 8 3L 61.681 11.000 140 46.874 to Zfc 0.0 61.681 4.583 * * Fixed Loss = 4.583 BF2 -3 52.61 8.27 0.0 72.681 0 0.002 Vel = 0.31 BF2 -3 0.0 8 G 5.012 33.500 150 51.459 to T 43.857 48.869 -1.299 TEST 0 52.61 7.68 0.0 82.369 0 0.002 Vel = 0.36 250.00 Qa = 250.00 TEST 302.61 50.162 K Factor= 42.73 Computer Programs by Hydratec Inc. Revision: 50.53.5