Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1000 AVIARA PKWY; 100; FPC2018-0139; Permit
PERMIT REPORT L5'cityof Carlsbad Print Date: 10/21/2021 Permit No: FPC2018-0139 Job Address: 1000 AVIARA PKWY, # 100, CARLSBAD, CA 92011-4218 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2120407000 Track #: Applied: 05/08/2018 Valuation: $24,138.69 Lot #: Issued: 08/01/2018 Occupancy Group: Project #: Finaled Close Out: 08/19/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: CUSH MAN & WAKEFIELD (C& W) OFFICE -FIRE ALARM TI Applicant: FPContractor: ELECTRONIC CONTROLS SYSTEM LLC ELECTRONIC CONTROL SYSTEMS LLC RICHARD SAYLORS 12575 KIRKHAM CT 12575 KIRKHAM CT POWAY, CA 92064-8844 POWAY, CA 92064-8844 (858) 513-1911 (858) 813-1911 FEE AMOUNT FIRE Plan Resub (3rd&Subsequent Submittal/hr) $132.00 FIRE TI Fire Alarm System $601.00 TOtal Fees: $733.00 Total Payments To Date: $733.00 Balance Due: $0.00 Fire Department Page _1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov f FUD is - () I ~ I _ Albireo Energy Partnering for Success C&WOffce 1000 Aviara Parkway, Suite 100 Carlsbad, CA 92011 Product Data Submittal Revision I Fire Alarm Tenant Improvement June 18, 2018 19' Albireo Energy. 12575 Kirkham Ct - Poway, CA 92064 P1ione:858-51-3-19f1wwwalbiieoenergy.com O _ Albireo Energy Partnering for Success Table of Contents 1. Equipment 1064 BPS6A SIGA-PS GCF-VM GCF-HDVM WG4WF-HVM C Existing Fire Alarm Control Panel (Provided for Reference Only) Notification Power Supply Photoelectric Smoke Detector Ceiling Mounted Strobe Ceiling Mounted Horn/Strobe WP Horn/Strobe 0 fl Albireo Energy. 12575 Kirkham Ct - Poway, CA 92064 • Phone:8-58-5i-3-19f1--wwwalbirieoenergy.com N Small Building Fire alarm Solutions Oui't ( - t T Intelligent Fire Alarm Systems 1064, i0l 000 WARQ cOWARO. is FDNY COA 6227 * 7165-1657: 0244 S fl Overview EDWARDS brand intelligent life safety systems offer the power of high-end intelligent processing in configurations that deliver uncomplicated solutions for small to mid-sized applications. With intelligent detection, electronic addressing, automatic device mapping, optional Ethernet® connectivity, and a full line of easily- configured option cards and modules, these flexible systems offer versatility that benefits building owners and contractors alike. The 1064 provides one Class B intelligent device loop that sup- ports up to 64 device addresses, and two Class B Notification Ap- pliance Circuits (NACs). Optional Class A device wiring is available with the use of a module. The 101000 provides one Class A or Class B intelligent device loop that supports up to 250 device addresses. Loop controller modules may be added in combination to expand total system capacity in 250-point increments to up to 1,000 device addresses. The iO1000 panel includes four NACs that may be wired for either Class A or Class B operation. The RZII6-2 module adds even more capacity to iO installations by adding up to 16 conventional device circuits and two additional notification appliance circuits. This makes them an ideal retrofit solution that can accommodate new intelligent detectors, as well as existing conventional devices. iO Series supports a wide range of high-end features, including: Signature Series intelligent modules, detectors, and bases R-Series remote annunciators SIGA-REL Releasing Modules Fully integrated CO detection using Signature Series detec- tors with or without audible signaling Page 1 of 8 Features Auto-programming speeds installation time Supports Signature Series intelligent modules and detectors Combines the Signature intelligent releasing module with Signature multisensor detectors for reliable fire suppression Form C contacts for alarm and trouble, Form A for supervisory Electronic addressing with automatic device mapping Optional Ethernet port for diagnostics, programming and a variety of system reports Two programmable switches with LEDs and custom labeling Supports Genesis horn silence over two wires, and UL 1971-compliant strobe synchronization Class B or Class A wiring Ground fault detection by module Supports up to eight serial annunciators, (LCD, LED-only, and graphic interface) Can use existing wiring for most retrofit applications Upload/download remotely or locally Two-level maintenance alert reporting Pre-alarm and alarm verification by point Adjustable detector sensitivity 4 x 20 character backlit LCD display Optional earthquake hardening: seismic Importance Factor 1.5 Standalone operation Transmission test frequency by hour DAA SHEET E85001-0135 Not to ct, utxc fc nta-t cr purc -E. Issue I Application EDWARDS iO Series life safety systems are powerful intelligent solu- tions for small to mid-sized buildings. Advanced intelligent technol- ogy delivers the benefits of flexible system installation, while clean and easy-to-operate user interfaces make panel operation and system maintenance quick and intuitive. The smart choice Signature Series electronic addressing eliminates the tedium of setting dipswitches, and automatic device mapping ensures that each device resides on the system at its correct location. Mean- while, innovative programming allows the designer to customize the system to precisely suit the needs of the building owner. Reliability you can count on The inherent fault-tolerant characteristics of Analog/Addressable Technology boosts the reliability of EDWARDS fire alarm systems. When combined with i0 Series smoke and heat detectors, these systems deliver a level of dependability not previously available for small to mid-sized applications. All EDWARDS systems are built to exacting reliability benchmarks and meet international standards for quality, in addition to agency listings for dependability. Clear-cut remote annunciation Remote annunciation is a strong suit of the ID Series fire alarm systems. Up to eight annunciators can be installed on a single system. Compatible annunciators include a range of LED and LCD models that provide zone or point annunciation, as well as com- mon control capabilities. i0 control panels also supports graphic annunciation with optional RA Graphic Annunciator interface mod- ules. Each interface provides common control and 32 LEDs. Programming and remote diagnostics EDWARDS i0 Series life safety systems are simple to set up, yet offer advanced programming features that put these small building panels into a class of their own. The auto programming feature quickly gets the panel operational using factory default settings. Basic zone and point settings can be programmed through the front panel interface, so the system is up and running in no time. For more advanced system configuration and correlation groups programming, i0 Series systems interface to a PC running com- patible i0-CU software. This option offers full system configuration in the familiar Windows® operating environment. Connection is made to a laptop through the panel's optional RS-232 communi- cations port, which can also be used to connect a system printer. Among the many innovative features of iO Series control panels is the optional network card. This module provides a standard 10/100 Base T Ethernet® network connection that permits access to the control panel from any remote location with the correct communications protocols. The connection can be used to download to the panel from the 10-CU, or upload and view system reports using the iO-CU. Available system reports include: Correlation groups Device details Device maintenance History Internal status System configuration System status Walk test Dialer CO runtime Page 2 of 8 Flexibility built right in Two fully-programmable front panel switch/LED combinations pro- vide an added measure of flexibility. Their slide-in labels take the mystery out of custom applications, and present a clean finished appearance. Perfect for retrofits EDWARDS i0 Series control panels are particularly well-suited to retrofit applications. All connections are made over standard wiring - no shielded cable required. This means that in most situations existing wiring can be used to upgrade a legacy control panel to i0 technology without the expense or disruption of rewiring the en- tire building. i0 control panels also support the ingenious RZ116-2 Zone Module, which adds up to 16 conventional circuits and two NACs. This combination easily accommodates new intelligent detection alongside existing conventional circuits, making it an superior solution in the retrofit market. Signals with a difference i0 system NACs are configurable to fully support the advanced signaling technology of EDWARDS Genesis and Enhanced Integ- rity notification appliances. These devices offer precision synchro- nization of strobes to UL 1971 standards. For Genesis devices, enabling this feature allows horns to be silenced while strobes on the same two-wire circuit continue to flash until the panel is reset. A complete line of accessories 0 Series life safety systems are supported by a complete line of analog/addressable detectors modules and related equipment. Consult the Ordering Information section for details. Dimensions (3) (4) 0 T 0 0 0 • 0 0 0 0 0 04 08 10 0 0 10 1.' Surface Mounting Holes (3) Backbox with Door Attached Semi-hush mounting Holes (4) Backbox with door and trim kit attached. Panel dimensions, in (cm) Model DV D2 I D3 D4 I 05* I 08 07 08 09 01000 28.0 3.85 I 9.0 I 22.0 15.75 I 10.25 I 28.2 2.7 (71.1) (9.8) (22.8) (55.8) (40.0) (26.0) 1(11.1) I (71.6) I (6.8) 21.5 I 385 I7.5 I 15.5 14.25 I 10.25 j 4.5 21.7 2.7 (54.6) (9.8) 1(19.0) 1(39.4) (36.2) 1(26.0) (11.4) I (55.1) I (6.8) * Add 1-1/2 in. (3.81 cm) toOl and 05 dimensions for trim kit. The trim kit provides 0.75 inches (1.9 cm) of trim to the top, bottom, and sides of the backbox. DATA SHEET E85001-0135 Not to be u,ed for ristal5aton purpc,* Issue 1 . S Two Class B or two optional class A NACs Optional 10 A or 6.5 A Booster Power Supply Up to eight remote annunciato Ethernet (SA-ETl-l) DACT/Dialer (SA-DACT) RS-232 (SA-232) Relays: Two Form C, one Form A Each iO64 panel ships with one Signature loop controller that sup- ports 64 devices of any type. This panel's device capacity cannot be expanded. Four class B or two optional class A NACs Up to eight remote annunciators Sixteen Conventional lDCs, two additional NACs with RZ116-2 module Panel Layout 10 1 Transformer 2 Main AC wiring block & fuse holder 3 RS-232 card connector (J3) 4 Dialer card connection (J8) 5 Ethernet card connector (Ji) 6 Main circuit board 7 Panel backbox enclosure 8 Operator interface 9 SLC card connector (J7) 10 Class A card connector (J2) 11 Tie wrap mounts 12 LED expander connector (J6) 13 Standby batteries System Layout C i0l 000 Any combination of two single- or dual Signature loop modules Standard Loop: 250 points~on"eexpansion slot) uO-SDC2 Expander, Loop 1 of 2: 250 points Up to-125-sensors lOP (one expansion slot) 0 iO-SDC1 Expander Loop: 250 p ints (one expansion slot) iO-SDC2 Expander, Loop 2 of 2: 250 points Up to 20, 000 feet - ----- --- -- ------------------------------- ------------------ ------------------------------------------------------------------ CIassBoioopIionalciassANA 1 UFo . ,, ptioal 10 A or 6.5 A Booster Ethernet (SA-ETH) _j DACT/Dialer RS-232 (SA-232) ; rr Relays: Two Form C, one Form A Each iOl000 panel has room for up to two Signature loop control- ler modules in any combination of single or dual 250-device loops. i01000 loops support 125 detectors and 125 modules. C 1064 II_ LZ L_ c Ago -/ Loop supports up to 64 intelligent devices of any type. Up to 20,000 feet of wiring. Page 3 of 8 DATA SHEET E85001-0135 Not to be used for .nLta, aton purposes. Issue I Class 8 wiring Class A wiring NC NO Alarm Trouble i Supervisory Type Form C Form A Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive Relay circuits can only be connected to power-limited sources. Annunciator loop (TB4) The control panel provides a connection for up to eight serially driven and supervised remote annunciators. Circuit specifications Device loops Class B (Style '1) or Class A (Style Z) Circuit voltage 2.55 V Circuit current 30 mA max Circuit Up to 8 annunciators or 4000 feet impedance Class B Class A Channel 1 Channel 2 Channel 1 Channel 2 +—+— Annunciator CHI (.) IN )CH1 (-) IN IN IN DATA SHEET E85001-0135 Not to be used for tnstr:lation puroo.eL. Issue 1 Wiring & Configuration Signature device loop The system provides one Signature device loop circuit with a total capacity of 125 detectors and 125 module addresses. The loop circuit is supervised for opens, shorts, and grounds. Circuit 101000 i064 specifications Device loops One Class B or A One Class B or A loop, loop, supporting 125 supporting 64 devices of detectors and 125 any kind. modules. Expandable to four loops. I Communication Maximum 20 V peak-to-peak line voltage Circuit current 0.5 A max Circuit 660 total, 0.5 pF, max impedance Isolators 64 maximum Signal Supported on a system-wide basis (all device loops) Synchronization when using a SIGA-CC1 S or SIGA-MCC1 S module and Genesis or Enhanced Integrity notification ap- pliances. Class B wiring Class A wiring Dam Une Loop Loop LW Loop Loop coA donlco donico oopco,d Data Lino Notification appliance circuits (TB2) 01000 control panels come equipped with four notification ap- pliance circuits. i064 control panels come with two NACs. Each circuit can be individually configured for continuous, temporal, synchronized, and coded output. Specifications i01000 I1064 Circuit Type 4 Class B or 2 Class A 2 Class B or 2 Class A with SA-CLA module Voltage 24VFWR Current 6.0 A total, 2.5 A max. 3.75 A total, 2.5 A max. per circuit at 120/230 per circuit at 120/230 VAC 60 Hz. VAC 60 Hz. 5.0 A total, 2.5 A max. 3.0 A total, 2.5 A max. per circuit at 230 VAC i per circuit at 230 VAC 50 Hz. 50 Hz. Impedance 26 0 total, 0.35 pF max EOLR 15K0 1/2 W Synchronization Supported system-wide OLR OLR Marking indicates output signal polarity when the circuit is active. Polarity reverses when the circuit is not active. Wire notification appliances accordingly. Notification appliance polarity shown in active state. Page 4 of 8 Auxiliary & smoke power outputs (TB3) The control panel provides two auxiliary power outputs that can be used for powering ancillary 0 -_ equipment such as remote annunciators and two (1) 01 wire smoke detectors. Aux 2 can be software - selected to operate continuously. The circuit is 0 supervised for shorts and grounds. 0 (2) - Circuit specifications 0 Circuit voltage 21.9 to 28.3 V - range Resettable circuit 24 VDC nominal at 500 mA (3) 0 (Aux power 2) 55 Continuous circuit 24 VDC nominal at 500 mA. (Aux power 1) Use this circuit for powering 0 two-wire smoke detectors. (4) - Note: Any current above 0.5 amp connected to both Aux - 1 and 2 will reduce the total available NAC power by that 0 amount. - (1) Trouble Alarm, trouble, and supervisory relay (TB3) (2) Supervisory The trouble relay is normally-open, held closed, (3) Alarm and opens on any trouble event or when the panel is de-energized. The supervisory relay is (4) Smoke/Aux normally-open, and closes on any supervisory event. The alarm relay changes over on any alarm event. Relay specifications Option Cards S S EDWARDS iO Series panels are supported by a complete line of modules and related equipment that enhance performance and extend system capabilities. Option cards plug directly into the control panel main circuit board or are connected to it with a ribbon cable. After installation, terminals remain accessible. The cabinet provides ample room for wire routing, keeping wiring neat at all times. Single and Dual Loop Controller Cards The iO-SDC1 is a single loop controller card that can be used with the i064 as a replacement for the standard 64-point loop, or with the i01000 as a 250-point expansion module. The i0-SDC2 is a 500-point dual loop controller card for the 01000 that provides two SLC circuits, each with 125 detector addresses and 125 module addresses. Specifications iO-SDC1 iO-SDC2 Device Addresses i01000: one loop, 250 iO1000: two loops, device addresses 500 device addresses i064: 64 addresses Wiring - Class B or Class A Operating Voltage 24 VDC Operating Current (fully loaded loop) Standby: 55 mA Standby: 45 mA I Alarm: 80 mA Alarm: 70 mA Note: These ratings do not include the use of two-wire smoke modules. Communication Line Voltage Max. 20.6 V peak-to-peak Terminal Rating 12 to 18 AWG (0.75 to 2.5 mm2) Circuit Current 0.5 A max. Max total loop resistance 660 Max total loop capacitance 0.5 pF Isolators 64 isolators maximum per loop (total both isolator bases and modules) Ground Fault Impedance 0 to 5 IcC) Operating Environment 32 to 120°F (0 to 49°C) 0 to 93% noncondensing at 90°F (32°C) SA-ETH Ethernet Interface Card SA-ETH wiring The SA-ETH card provides a To network Connection standard 10/100 Base T Ether- net network connection for Network connecting to an intranet, a local network, or the Internet. The card can be used to download Go configuration programming from 13 the iO-CU to the panel. Eu The Ethernet card is installed on the plastic assembly and con- Ethernet card nects to the main circuit board via a ribbon cable. SA-ETH specifications Ethernet 10/100 Base T Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Page 5 of 8 RZII6-2 Remote Zone Interface Module The RZ116-2 Addressable Remote Zone Interface Module is an addressable device that provides connections for sixteen Class B Initiating Device Circuits and two Class B Supervised Output Circuits. The inputs and outputs can be configured individually for several device types. It requires 18 consecutive addresses on the Signaling Line Circuit (SLC). Addresses are assigned electronically. There are no address switches to set. The RZ116-2 incorporates two 8-segment DIP switches that are used to select the Alarm or Supervisory default device type for each of the 16 IDC circuits. The module also includes one 4-seg- ment DIP switch used to select the default Relay or NAC output device type. Device types other than the default are accomplished through programming. RZI16-2 Specifications Voltage 24V/Aux nominal: 24 VDC Supervisory current: 250 mA at 24 VDC nominal Alarm Current 1000 mA 24V/Aux minimum: 18.4 VDC 24V/Aux maximum: 26.4 VDC NAC1, NAC2 nominal: 24 VDC Current Standby current for 4.7 k EOL (U.S.) 4.8 mA' circuit Standby current for 3.9 k EOL (Canada) 5.7 mA/ circuit Alarm current at nominal voltage 31.1 mA' circuit Relay outputs Quantity 2 Type Rating (pilot duty) Programmable 24 VDC at 2.5 A Input circuit wiring 25 C) per wire resistance Initiating device circuits Quantity 16 EOL resistor 4.7 kC) (U.S.); 3.9 Ic!) Canada Zone voltage 22.78 V for 4.7 IcC) (U.S.) 22.08 V for 3.9 Ic!) (Canada) Alarm current 31.1 mA' channel at nominal voltage Alarm impedance range <680 C) Trouble impedance range > 5.55 kf) Supervised output circuits EOL resistor 15 IcC) Quantity 2 Short circuit detection <2.6 IcC) Open circuit detection > 61.9 kC) Contact ratings 24 VDC at 2.5 A (5 A for two NACs) Compatible cabinets MFC(A), iO1000, APS T E85001 -0135 issue SA-DACT Dialer The SA-DACT provides communications between the control panel and the central station over a telephone line system. It transmits system status changes (events) to a compatible digital alarm communicator receiver over the public switched telephone network. The dialer is capable of single, dual, or split reporting of events to two different account and telephone numbers. The modem feature of the SA-DACT can also be used for uploading and downloading panel configuration, history, and current status to a PC running the iO-CU. SA-DACT Phone line2 _ wiring To wall a line 1 phone jack Phone cables (supplied) —J The dialer phone lines connect to connectors on the dialer's main circuit board. Phone line 1 connects to connector J4 and phone line 2 connects to connector J1. The SA-DACT queues mes- sages and transmits them based on priority (alarm, supervisory, trouble, and monitor). Activations are transmitted before restora- tions. The SA-DACT is installed on the plastic assembly and connects to the main circuit board via a ribbon cable. SA-DACT specifications Phone line type One or two loop-start lines on a public, switched network Phone line connector RJ-31/38X (C31/38) Communication formats Contact ID (SIA DC-05) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondertsing at 90°F (32°C) Compatible DACRs Receiver Models Formats - Ademco 685 Contact ID FBI CP220 Contact ID Osborne-Hoffman OH 2000 Contact ID Bosch D6600 Contact ID Silent Knight 9800 Contact ID Sur-Gard SG-MLR1, MLR2 Contact ID Page 6 of 8 SA-232 RS-232 interface SA-232 wiring The SA-232 card provides an RS-232 in- GND (black wire) terface with iO panels. It can be used for TXD (white wire) connecting a printer to the control panel F1 F RXO (red wire) to print system events. The card also ______ can be used for connecting a computer Ej ______ to download a configuration program '0 00 from the iO-CU to the control panel. The RS-232 card is installed on the plas- tic assembly and connects to the main circuit board via a ribbon cable. SA-232 specifications Operating voltage Standard EIA-232 Terminal rating 12 tol8 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) SA-CLA Class A Module (i064 only) The SA-CLA card provides Class A capability for NAC wiring. Its terminal block provides the wiring connection for NAC return wiring. The card is required for annunciator Class A wiring even though this wiring does not return to the SA-CLA card. The SA- CLA is compatible with i064 control panels only iO1000 panels are Class A Ready. The SA-CLA is installed directly to the control panel circuit board using its plastic standoffs and plug connection. SA-CLA specifications Operating voltage 24 VF\NR Operating current 3.75 A FWR total at 120/230 VAC 60 Hz 3.0 A RNR total at 230 VAC 50 Hz 2.5 A max per circuit Circuit impedance 26 ohms, 0.35uF Terminal rating 12 tol8 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) DI6L-iO LED Display Expander (i01000 only) The D16L-iO LED Display Expanders provide LED annunciation for up to 16 zones. It provides two LEDs for each zone. Two D16L-iO LED display expanders can be installed in each i01000 panel. (3) (4) 77.7, 77.777 E85001-0135 Issue 1 LED 1 LED 2 LED Expander 1 LED Expander 2 Jarm/non-alarm and trouble zone LEDs S S S S S Specifications 064 i01000 Device loops 1 loop Class B or Class A (Styles 4, 6, 7) supporting up to 1 loop, expandable to 4, Class A or B (Styles 4, 6, 7), 64 device addresses (any combination of detectors and each loop supporting up to 250 device addresses (125 modules) detectors and 125 modules max.). Addresses 1 to 125 are Maximum 1-taps: 63 for detectors and addresses 126 to 250 are for modules (each device can be on its own branch) Maximum T-taps/loop: 124 Notification appliance 2 Class B (Style 'i'), Class A (Style Z) optional 4 Class B (Style ' or 2 Class A (Style Z) circuits 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max. per circuit 2.5 A FWR each max. per circuit Primary power 120 VAC, 60 Hz, 1.3 A max. 120 VAC, 60 Hz, 2.0 A max. 230 VAC, 50-60 Hz, 0.62 A max. 230 VAC, 50-60 Hz, 0.97 A max. Base panel current standby 155 mA 172 mA Base panel current alarm 204 mA 267 mA Input zones 16 max. 32 max. Remote annunciator 8 drops max., RS-485 Class B, Class A is optional 8 drops max., RS-485 Class A or B Data line length: 4,000 ft. (1,219 m) Data line length: 4,000 ft. (1,219 m) Operating voltage 24 VDC panel Auxiliary power output Aux power 1: 500 mA, 24 VDC circuit Aux power 2: 500 mA, 24 VDC (1 A possible if you reduce total available NAC power by 500 mA) Output: 28.3 to 21.9 VDC, special application Note: For a list of compatible devices, see the i064 and i01000 Series Compatibility List (P/N 3102353-EN) Loop circuit Maximum loop resistance: 66 0 Maximum loop capacitance: 0.5 iF Communication line voltage: Maximum 20.6 V peak-to-peak Operating current (fully loaded loop) Stand by: 55 mA/45 mA Alarm: 125 mA/1 15 mA (not including two-wire smoke modules) Circuit current: 0.5 A max. Style 4, 6, and 7 wiring Max. resistance between isolators: Limited only by overall wire run lengths 64 isolators maximum per loop (total both isolator bases and modules) Batteries Type: Sealed lead acid Voltage: 24 VDC Charging current: 2.47 A max. Amp hour capacity: 26 Ah Standby operation: 24 hour or 60 hour Placement: Up to two 10 Ah batteries will fit in the i064 control panel cabinet and two 18 Ah batteries will fit in the iOl 000 control panel cabinet. If larger batteries are required, use an EDWARDS battery cabinet. SA-DACT dialer Phone line type: One or two loop-start lines on a public, switched network Phone line connector: RJ-31/38X (C31/38)) Communication formats: Contact ID (SIA DC-05) Operating current Standby/Alarm: 41 mA Max.: 100 mA FCC registration number: GESAL01 BSADACT Industry Canada Registration number: 3944A-SADACT Ringer equivalence number: 0.1 B Ground fault impedance 0 to 5 kfl Alarm contact Form C N.C. 24 VDC at 1 A (resistive load) Trouble contact Form C 24 VDC at 1 A (resistive load) Supervisory contact Form A N.C. 24 VDC at 1 A (resistive load) Environmental Temperature: 0 to 49°C (32 to 120°F) Relative humidity: 0 to 93% noncondensing Terminal rating All terminals rated for 12 to 18 AWG (0.75 to 2.5 mm2) - Page 7 of 8 DATA SHEET E85001-0135 Not to be used for nstaIat,on purposes. Issue I LIFE SAFETY b. INCIDENT MANAGEMENT Contact us... Email: edwards.firi@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. S Ordering Information Part Description i01000 Fire Alarm Systems 101000G Four loop system with one 250-point loop installed. 110v, gray door. 01000G-2 Four loop §Ystem with one 250-point loop instatled. 230v, gy door. l01 000G-2-PG Four loop system with one 250-point loop installed. 230v, gray door, Portuguese. I01000G-2-SP Four loop system with one 250-point loop installed. 230v, gray door, Spanish. I01000G-CA Four loop system, one 250-point loop installed. 1l0v, gray door, LED strips, Canada. I01000GD Four loop system, one 250-point loop installed. 110v, gray door, with dialer. I01000G-F Four loop system, one 250-point loop. 110v, gray door, LED strips, French Canada. 101000G-PG Four looD system with one 250-ooint boo installed. 110v. arav door. Portuauese. I01000R-2 Four loop system with one 250-point loop installed. 230v, red door. I01000RD Four loop system, one 250-point loop installed. 110v, red door, with dialer. SA-TRlM2 iO1000 Rush mount trim, black. i064 Fire Alarm Systems 1064G One loop system with one 64-point loop installed. 110v, gray door. 1064G-2 One loop system with one 64-point loop installed. 230v, gray door. 1064G-2-PG One loop system with one 64-point loop installed. 230v, gray door, Portuguese. 1064G-2-SP One loop system with one 64-point loop installed. 230v, gry door, Spanish. 1064G-PG One loopystem with one 64-point loop installed. 11 Ov, gy door, Portuguese. 1064G-SP One loop system with one 64-point loop installed. 11 Ov, gray door, Spanish. 1064R One loop system with one 64-point loop installed. 110v, red door. 1064R-2 One loop system with one 64-point loop installed. 230v, red door. 1064RD One loop system, one 64-point loop installed. 110v, red door, with dialer. SA-TRIM1 i064 Flush mount trim, black Option Cards iO-SDC1 Expansion module, one 250-device loop. O-SDC2 Expansion module, two 250-device loops, 500 devices total. For iOi 000 only. SA-ETH Ethernet Port, Slave, mounts in cabinet on base plate. SA-CLA Class A adapter module. Provides Class A capacity on NACs. Mounts in cabinet on main board. i064 systems only. D16L-iO-2 LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to right of LCD display for zones 17-32. For i01000 only. D16L-i0-1 LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to left of LCD display for zones 1-16: For iOi 000 only. D8RY-0-2 Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only, 8 supervisory only, 4 alarm or supervisory). Mounts in cabinet. For iO1 000 only. D8RY-0-1 Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only, 8 supervisory only, 4 alarm or supervisory). Mounts in cabinet. For iOl000 only. Accessories CTM City Tie Module. 2-gang. Connection to a local energy fire alarm box. MFC-A Multifunction Fire Cabinet, 8" x 14" x 3.5" - red. SIGA-REL Releasing Module PT-1S System Printer BC-1 Battery Cabinet. 14.0" x 18.25" x 7.25. Holds two 12V24A batteries. BC-1R Battery Cabinet - Red. 14.0" x 18.25" x 7.25". Holds two 12V24A batteries. BC-i EQ Seismic hardening Kit for iO series panels. Includes battery hardening for BC-11 enclosure and components to harden panel internal components. Programming Tools and Page 8of8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1 S tII!llII// 111'1't'//iii I MEA 476-91-E Vol. 13 S3424_ * 7300-1657: 0229 Standard Features ,Ailows for reliable filtered and regulated power to be installed where needed Cost effective system expansion Provides for Genesis and Enhanced Integrity notification ap- pliance synchronization Supports coded output operation Self-restoring overcurrent protection Multiple signal rates Can be cascaded or controlled independently Easy field configuration On-board diagnostic LEDs identify wiring or internal faults Standard EDWARDS keyed lockable steel cabinet with re- movable door 110 and 230 Vac models available Accommodates 18 to 12 AWG wire sizes Optional tamper switch Dual battery charging rates Optional earthquake hardening: OSHPD seismic pre-approval for component Importance Factor 1.5 Power Supplies and Accessories I-F cr ç • GE ry Remote Booster Power Supplies BPS6A, BPS1OA Overview The BPS contains the circuitry to monitor and charge internal or external batteries. Its steel enclosure has room for up to two 10 ampere-hour batteries. For access control-only applications, the BPS can support batteries totaling up to 65 ampere-hours in an external enclosure. The BPS has four Class B (convertible to two Class A) NACs. These can be activated in one or two groups from the BPS's unique dual input circuits. The BPS is available in 6.5 or 10 ampere models. Each output circuit has a capacity of three amperes; total current draw cannot exceed the unit's rating. The BPS meets current UL requirements and is listed under the following standards: Standard (CCN) Description UL864 9th edition (UO)OqFire Alarm Systems UL636 (ANET, UEHX7) Holdup Alarm Units and Systems UL609 (AOTX, AOD(7) Local Burglar Alarm Units and Systems UL294 (ALW, UEHX7) Access Control systems UL365 (APAW, APAW7) Police Station Connected Burglar Alarm Units and Systems UL1 076 (APOU, APOU7) Proprietary Burglar Alarm System Units UL1 610 (AMC) Central Station Alarm Unit ULC-5527 (UO)0(C) Control Units, Fire Alarm (Canada) ULC-5303 )AbD<7) Local Burglar Alarm Units and Systems (Canada) C22.2 No. 205 Signaling Equipment (Canada) S The Booster Power Supply (BPS) is a UL 864, 9th Edition listed S power supply. It is a 24 Vdc filtered-regulated, and supervised unit that can easily be configured to provide additional notification appliance circuits (NACs) or auxiliary power for Mass Notification! Emergency Communication (MNEC), as well as life safety, security, and access control applications. Page lof4 DATA SHEET E850050125 Not to be used for installation purposes. Issue 1 Power-limited wiring area Application The BPS provides additional power and circuits for notification ap- pliances and other 24 Vdc loads. It is listed for indoor dry locations and can easily be installed where needed. Fault conditions are indicated on the on-board diagnostic LEDs, opening the BPS input sense circuit and the trouble relay (if programmed). While this provides indication to the host system, the BPS can still be activated upon command. A separate AC Fail contact is available on the BPS circuit board, which can be programmed for trouble or AC Fail. There are seven on-board diagnostic LEDs: one for each NAC fault, one for battery fault, one for ground fault, and one for AC power. The unique dual-input activation circuits of the BPS can be acti- vated by any voltage from 6 to 45 VDC (filtered-regulated) or 11 to 33 Vdc (full-wave rectified, unfiltered). The first input circuit can be configured to activate 1-4 of the four possible outputs. The second input circuit can be configured to control circuits 3 and 4. When outputs are configured for auxiliary operation, these circuits can be configured to stay on or automatically deactivate 30 sec- onds after AC power is lost. This feature makes these circuits ideal for door holder applications. The BPS also has a separate 200 mA 24 Vdc output that can be used to power internal activation modules. BPS NACs can be configured for a 3-3-3 temporal or continuous output. California temporal rate outputs are also available on cer- tain models. This makes the BPS ideal for applications requiring signaling rates that are not available from the main system. Dimensions D5Q 001 Top View D2 -'l Ii D3 o a) 04— D4 —P,0 S S Front View View S 0 a) Cn U 66 0 . S cn I All knockouts CD I for 3/4 in conduit <I (1.9 cm) S S CD I Dl D2 D3 D4 05 D6 17.0 in 3.5 in 13.0 in 6.5 in 3.375 in 12.0 in (43.2 cm) (8.9 cm) (33.0 cm) (16.5 cm) (8.6 cm) (30.4 cm) Dl In addition to the internally generated signal rates, the BPS can also be configured to follow the coded signal rate of the main Wire routing system NACs. This allows for the seamless expansion of existing NACs. The BPS enclosure has mounting brackets for up to three Signa- ture modules to the right of the circuit board. Engineering Specification Supply, where needed, EDWARDS BPS Series Booster Power Supplies (BPS) that are interconnected to and supervised by the main system. The BPS shall function as a stand-alone auxiliary power supply with its own fully-supervised battery compliment. The BPS battery compliment shall be sized to match the require- Route AC supply ments of the main system. The BPS shall be capable of supervis- through these ing and charging batteries having the capacity of 24 ampere-hours knockouts only for Mass Notification/Emergency Communication (MNEC), life (Nonpower-limited safety and security applications, and the capacity of 65 ampere- and supervised) hours for access control applications. <<The BPS shall be capable of installation for a seismic com- ponent Importance Factor of 1.5.>> The BPS shall provide a minimum of four independent, fully supervised Class B circuits that can be field configurable for notification appliance circuits or auxiliary 24 Vdc power circuits. BPS NACs shall be convertible to a minimum of two Class A NACs. Each BPS output circuit shall be rated at 3 amperes at 24 Vdc. Each output circuit shall be pro- vided with automatically restoring overcurrent protection. The BPS shall be operable from the main system NAC and/or EDWARDS Signature Series control modules. BPS NACs shall be configurable for continuous, 3-3-3 temporal or optionally, California rate. Fault conditions on the BPS shall not impede operation of main sys- tem NAC. The BPS shall be provided with ground fault detection circuitry and a separate AC fail relay. Page 2 of 4 Notes 1. Maintain 1/4-inch (6 mm) spacing between power-limited and nonpower-limited wiring or use type FPL, FPLR, or FPLP cable per NEC. Power-limited and supervised when not configured as auxiliary power. Non- supervised when configured as auxiliary power. Source must be power-limited. Source determines supervision. 4. When using larger batteries, make sure to position the battery terminals towards the door. S DATA SHEET E85005-0125 Not to be used for installation purposes. Issue 1 Configuring the Booster for AC Power Fail delay operation* TRI I Notification appliance circuit Data in from previous device or signature controller UL listed EOL 15 kC) Notification appliance circuit (NAC) UL listed EOL 15 lcD • . Data in from \_J I 14~ Data out to moul[4]1 or Signature CT1 previous device :5- -+ next device 3 2 1 controller V. *The Booster supports AC Power fail delay Data out to of three hours via its trouble contact when next device dip switch SW2-6 is on. Al other troubles are reported to supervising module or panel without delay via Sense inputs. EOL 47 kO CC1(S) module [1][3] 00 Multiple CC1(S) modules using the BPS's sense inputs TB1 Notification appliance circuit (NAC) NAC1/ + UL listed AUX1 KW ficationappliance circuit NAC) NAC2J + AUX2 NAC3/ + UL listed AUX3 - EOL 15 KW NAC4/ + AUX4 - 200 mAAUX Ln Continuous Co IN Sense 1 COM OUT IN Sense 2 COM OUT NO Trouble COM NC E0L47 K E0L47 K CC1(S) module 00 CC1(S) module 00 [3] Typical Wiring Single or cascaded booster anywhere on a notification appliance circuit Existing NAC end-of-line resistors are not required to be installed at the booster's terminals. This allows multiple boosters to be driven from a single NAC circuit without the need for special configurations. NAC Circuit I To next signaling NAC Circuit \.\/ device, booster, or EOL resistor (I) (I) I CD CD I ) NAC output #1 Fire Alarm I C.) NAC output #2 Control Panel CD I ) NAC output #3 )NAC output #4 C = Booster Power Security and access BPS TB 24 V 12 V / Ti 4D evic security / +E CNAC3/ L______J ,+ - I Control panel [1] Disable the BPS's ground fault jumper (JP3) . Page 3 of 4 = Security EOL device moitoring device BPS [1] Card reader Card reader Card reader controller controller controller +— +— To next device or end DATA SKEET E85005-0125 Not to be used for installation purposes. Issue 1 Specifications E DVVAR DS Model 6.5 amp Booster 10 amp Booster. AC Line Voltage 120 VAC or 220-240VAC 50/60Hz 120 VAC or 220-240VAC 50/60Hz 390 watts 580 watts ::T Ft' N1IN 1.4iIEI.1Et Notification Appliance 3.0A max. per circuit @ 24Vdc 3.0A max. per circuit © 24Vdc Circuit Ratings nominal 6.5A max total all NACs nominal 1 O max total all NACs Contact us... Trouble Relay 2 Amps © 30Vdc Email: edwards.fire@fs.utc.com Auxiliary Outputs Four configurable outputs replace NACs 1 2, 3 or 4. as auxiliary Web: Edwards-fire.com outputs and 200 mA dedicated auxiliary. (See note 2.) Input Current 3mA © 12Vdc, 6mA © 24Vdc EDWARDS is a UTC brand. (from an existing NAC) 1016 Corporate Park Drive Booster Internal 70mA + 35 mA for each circuit set to AUX Mebane, NC 27302 Supervisory Current Booster Internal Alarm © 2016 United Technologies Corporation. 270mA Current All rights reserved. Signature Mounting Accomodates three two-gang modules. Maximum Battery Size 10 Amp Hours (2 of 12V1 0A) in cabinet up to 24 Amp hours with ex- ternal battery cabinet for fire and security applications; up to 65 Amp hours for access control applications in external battery box. Terminal Wire Gauge 18-12 AWG Relative Humidity 0 to 93% non condensing © 32°C Temperature Rating 32° to 120°F (00 to 49°C) NAC Wiring Styles Class A or Class B Output Signal Rates Continuous, California rate, 3-3-3 temporal, or follow installed panel's NAC. (See note 1.) Ground Fault Detection Enable or Disable via jumper Agency Listings UL, ULC, CSFM Model BPS'CAA. provides selection for California rate, in place of temporal Maximum of 8 Amps can be used for auxiliary output. Page 4 of 4 Ordering Information Catalog Description Shipping BPS6CM 6.5 Amp Booster Power Supply with California rate 13 ( 5.9) PS10A 10 Amp Booster Power Supply 13(5.9) BPS1OAC 10 Amp Booster Power Supply (ULC) 13(5.9) BPS1 DA/230 10 Amp Booster Power Supply (220' 13(5.9) BPS1 0CM 10 Amp Booster Power Supply with California rate 13(5.9) Requires installation of sepa- rate battery cabinet. Related Equipment BPS supports batteries greater 12V6A5 7.2 Amp Hour Battery, two required 3.4 (1.6) than 24 Amp hours for access 12V1 DA 10 Amp Hour Battery, two required 9.5 (4.3) control applications only. For earthquake anchorage, 3-TAMP Tamper switch including detailed mounting BC-i EQ Seismic Kit for BC-1. Order BC-1 separately. See note 3. weights and center of gravity BPSEQ Seismic kit for BPS6A or BPSi 0 Booster Power Supplies. See detail, refer to Seismic Applica- note 3 tion Guide 3101676. Approval of panel anchorage to site BC-1 ____________________________________________________________________________________________ Battery Cabinet (up to 2 - 40 Amp Hour Batteries) 58 (26.4) structure may require local BC-2 Battery Cabinet (up to 2 - 17 Amp Hour Batteries) 19(8.6) AHJ, structural or civil engineer 12V1 7A 18 Amp Hour Battery, two required (see note 1) 13(5.9) review. 12V24A 24 Amp Hour Battery, two required (see note 1) 20 (9.07) 12V40A 40 Amp Hour Battery, two required (see notes 1, 2) 32 (14.5) 12V50A 50 Amp Hour Battery, two required (see notes 1, 2) 40 (18.14) 12V65A 65 Amp Hour Battery, two required (see notes 1, 2) 49 (22.2) -iET E85005-0125 t'j ;c t. rstalatr pur:osis. Issue I S S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. QZQ0t65i0229) Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models BPS10A, BPS6A/230, BP510A1230, BPS6CAA, and BPS10CAA remote booster power supplies. *Models APS6A, APS6N230, APS6CAA, APS1OA, and APS10A/230 Auxiliary Power Supply. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 120 V/240 V, 60 Hz, 50 Hz INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as remote booster power supplies for use with listee's separately listed compatible fire alarm control units to extend the notification appliance circuit. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:229 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division FM * e 7272-1657: 0126 c';AH: :-a: P Intelligent Initiating rE rcy :: C.ELT :.l,ACr1ENT Intelligent Dk+rmIir'+rc' I I IL.'L¼JcIL,LI ILi Smoke Detector SIGA-PS Overview The Signature Series Model SIGA-PS Intelligent Photoelectric S Smoke Detector gathers analog information from its smoke sens- ing element and converts it into digital signals. The detector's on-board microprocessor measures and analyzes these signals. It compares the information to historical readings and time patterns to make an alarm decision. Digital filters remove signal patterns that are not typical of fires. Unwanted alarms are virtually elimi- nated. The microprocessor in each detector provides four additional ben- efits - Self-diagnostics and History Log, Automatic Device Map- ping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series detector constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in the detector's non-volatile memory Automatic Device Mapping - The loop controller learns where each device's serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each device's installed location to prevent a detector from being reinstalled (after cleaning etc.) in a different location from where it was originally. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the loop controller when it has something new to report. Standard Features Integral microprocessor Non-volatile memory Automatic mapping device Electronic addressing Environmental compensation Intelligent detector Wide 0.67% to 3.77%/ft. sensitivity range Twenty pre-alarm sensitivity values, set in 5% increments Identification of dirty or defective detectors Automatic day/night sensitivity adjustment Twin RED/GREEN status LEDs Standard, relay, fault isolator, and audible mounting bases Designed and manufactured to ISO 9001 standards S Page 1 of DATA SHEET E85001-0269 Not to be used for instaliaton purposes. Issue 1 nstaIation Signature Series detectors mount to North American 1-gang boxes, 3-1/2 inch or 4 inch octagon boxes, and to 4 nd- square electrical boxes 1-1/2 inches (38 mm) deep. They mount to Euro- pean BESA and 1-gang boxes with 60.3 mm fixing cen:ers. \/ ,J1 0.8 (20 mm) 2.0'(51 mm) = I I 4.4'(112 mm) Tamper-Resist Lever Arm - Break oft to disable - (Located on Base) Access Slot for Tamper-Resist Mechanism 11 W1, Testing & Maintenance Each detector automatically identifies when it is dirty or defective and causes a "dirty detector" message. The detector's sensitiv- ity measurement can also be transmitted to the loop con:roller. A sensitivity report can be printed to satisfy NFPA sensitivty meas- urements which must be conducted at the end of the first year and every two years thereafter. The user-friendly maintenance program shows the currert state of each defector and other pertinent messages. Single detectors may be turned off temporarily from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper detec- tor operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFFA 72 and ULC CAN/ULC 536 standards. Compatibility The SIGA-PS detectors are compatible only with the Signature Loop Controller. Warnings & Cautions This detector will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your fire protection specialist. This detector will NOT sense fires that start in areas where smoke cannot reach the detector. Smoke from fires in walls, roofs, or on the opposite side of closed doors may not reach the detector to alarm it. Page 2 of 4 Accessories All detector mounting bases have wiring terminals that are acces- sible from the "room-side" after mounting the base to the electri- cal box. The bases mount to North American 1-gang boxes and to 31/2 inch or 4 inch octagon boxes, 11/2 inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The SIGA-SB4, SIGA-RB4, and SIGA-1134 mount to North American 4 inch sq. electrical boxes in addition to the above boxes. They include the SIGA-T54 Trim Skirt which is used to cover the "mounting ears" on the base. The SIGA-AB4G mounts to a 4" sqare box only. '. Air , SIGA-AB4G SIGA-SB SIGA-IB SIGA-RB SIGA-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Standard Base SIGA-SB, SIGA-SB4 - This is the basic mount- ing base for EDWARDS Signature Series detectors. The SIGA- LED Remote LED is supported by the Standard Base. Relay Base SIGA-RB, SIGA-RB4 - This base includes a relay. Normally open or closed operation is selected during installation. The dry contact is rated for 1 amp (pilot duty) @ 30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The SIGA-RB can be operated as a control relay if programmed to do so at the control panel (EST3 V.2 only). The relay base does not support the SIGA-LED Remote LED. Audible Base SIGA-AB4G - This base is designed for use where localized or group alarm signaling is required. When the detector senses an alarm condition, the audible base emits a local alarm signal. The optional SIGA-CRR Polarity Reversal Relay can be used for sounding to other audible bases on the same 24 Vdc circuit. Relay and Audible Bases operate as follows: - at system power-up or reset, the relay is de-energized - when a detector is installed in the base with the power on, the relay energizes for four seconds, then de-energizes - when a detector is removed from a base with the power on, the relay is de-energized - when the detector enters the alarm state, the relay is energized. Isolator Base SIGA-113, SIGA-1134 - This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the SIGA-LED Remote LED. The isolator operates as follows: - a short on the line causes all isolators to open within 23 msec - at 10 msec intervals, beginning on one side of the Class A circuit nearest the loop controller, the isolators close to provide the next isolator down the line with power - when the isolator next to the short closes, reopens within 10 msec. The process repeats beginning on the other side of the loop controller. Remote LED SlGA-LED - The remote LED connects to the SIGA-SB or SIGA-SB4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. SIGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. E85001-0269 - Issue C S Term Description 1 Normally Open 2 DATA IN/OUT (+) 3 Common 4 DATA IN)-) 5 Not Used 6 Normally-Closed 7 DATA OUT CONTACT RATING 1.0 Amp @30 VDC OUTC-) (Pilot Duty) Normally- Normally- DAT OAT,, From Signature Controller or Previous Device OUT (+) To Next Device Audible Detector Base, SIGA-AB4G Application Although photoelectric detectors have a wide range of fire sensing capabilities they are best suited for detecting slow, smoldering fires. The table below shows six standard test fires used to rate the sensitivity of smoke and heat detectors. The table indicates that no single sensing element is suited for all test fires. EDWARDS recommends that this detector be installed according to latest recognized edition of national and local fire alarm codes. - - SIGA-HRS and - - SIGA-HFS Rate-of- SIGA-PHS SIGA-IPHS Test Fire SIGA-PS Photo Rise/ Fixed Temp. Photo Heat 3D Ion/Photo/Heat 4D Open Wood unsuitable optimum very suitable optimum Wood Pyrolysis optimum unsuitable optimum optimum Smouldering Cotton optimum unsuitable optimum optimum Poly Urethane Foam very suitable suitable very suitable optimum n-Heptane very suitable very suitable optimum optimum Liquid Fire without unsuitable optimum very suitable very suitable Smoke Typical Wiring The detector mounting bases accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.5mm2), and #12 AWG (2.5mm2) wire sizes. Note: Sizes #16 AWG (1 .omm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Standard Detector Base, SIGA-SB, SIGA-SB4 . Relay Detector Base, SIGA-RB, SIGA-RB4 S Term Description 1 Not Used 2 DATA IN/OUT (~) 3 Not Used 4 DATA IN(-) 4 Remote LED (-) 5 Remote LED 6 Not Used 7 DATA OUT I-li 7TI DATA 0 U T I-) DATA IN 1+1 DATA OUT (+1 From Signature Controller To Next Device or Previous Device Isolator Detector Base, SIGA-113, SIGA-1134 Remote LED Max resistance — per wire must not exceed 10 Ohms DA1 DA1- 11N From Signature Controller or Previous Device Term Description 1 Not Used 2 DATA IN/OUT (i-) 3 DATA IN(-) 4 Not Used 5 Not Used 6 DATA OUT (-) 7 Not Used OUT (-) Volume sell Default = High volu Cut for low volu 24 Vdc in From power supply or previous base Data in From signature controller or previous device Tone setting Default = Temporal pattern ut for steady tone To configure output volume or lone, cut the ciro,it board as sham. 24 Vdc Out To next base or EOL relay Data out To next Signature device OUT (+) To Next Device S Page 3 of 4 DATA SHEET E85001-0269 Not to be used for installation purposes. Issue 1 S Specifications EDWARDS Sensing Element Photoelectric - Light Scattering Principle Storage & Operating Air Velocity Range: 0t0 5,000 ft/mm (0 to 25.39 m/s); Humidity: 0 t Environment 93% RH, Non-Condensing Operating Temp: 32°F to 120°F (0°C to LiFE SAFETY & INCIDENT MANAGEMENT 490C); Storage Temp: -4°F to 140°F (-20°Cto 60°C) Sensitivity Range ULI/ULC - 0.67% to 3.77% obscuration/foot Contact us... User Selected Alarm Most Sensitive: 1.0%/ft.; More Sensitive: 2.00/o/ft.; Normal: 2.5%/ft.; Email: edwards.fire@fs.utc.com Sensitivity Settings Less Sensitive: 3.00/o/ft.; Least Sensitive: 3.50/o/ft. Web: Edwards-fire.com Pre-alarm Sensitivity 5% increments, allowing up to 20 pre-alarm settings Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) EDWARDS is a Iflc brand. Operating Current (quiescent. 45p 19 Vrm: 45pP/@ 19 V Pulse Current: 100 pA 1016 Corporate Park Drive (100 msec). During Communication: 9 mA max. Mebane, NC 27302 Construction & Finish High Impact Engineering Polymer - White Compatible Mounting SIGA-SB Standard Base, SIGA-RB Relay Base, SIGA-113 Isolator Base, © 2016 United Technologies Corporation. Bases SIGA-AB4, SIGA-AB4G Audible Bases All rights reserved. LED Operation On-board Green LED - Rashes when polled; On-board Red LED - Flashes when in alarm. Compatible Remote Red LED (model SIGA-LED) Flashes when in alarm. Compatibility Use With: SIGNATURE Loop Controller Address Requirements Uses one Device Address Agency Listings UL, ULC, MEA, CSFM, FM UL Listed Soacino 30 ft Ordering Information Catalog Description - - Ship Wt. Number lbs (kg) LS1GfSi Intelligent Photoelectric Detector - UL/ULC Listed 0.5 (.23) Accessories SlGA-SB Detector Mounting Base - Standard SIGA-SB4 4-inch Detector Mounting Base c/w SIGA-TS4 Trim Skirt SIGA-RB Detector Mounting Base w/Relay SIGA-RB4 4-inch Detector Mounting Base w/Relay, c/w SIGA-TS4 Trim Skirt 0.2 (.09) SIGA-I134 4-inch Detector Mounting Base w/ Fault Isolator, c/w SIGA-TS4 Trim Skirt SIGA-LED Remote Alarm LED SIGA-AB4G Audible (Sounder) Base .3(0.15) SIGA-TS4 Trim Skirt (supplied with 4-inch bases) .1 (.04) S Page 4of4 DATA SHEET E850010269 16 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. (7272 J657:0126 Page 1 of 1 CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conovercfs.utc.com DESIGN: Models and SIGA-PHS photoelectric smoke detectors. Model SIGA-PHS employs an integral 135°F fixed temperature heat sensor. This heat sensor is a supplementary device to the smoke detector and is not approved as a required heat detector. Refer to listee's printed data sheet for additional detailed product description, installation and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee's listed fire alarm control units and Model SIGA Series bases (CSFM Listing No. 7300-1657:120). Model SIGA-PS may be suitable for installation directly in the duct with the velocity range from 0-5000 feet/mm. NOTE: Model SIGA-PHS is not intended for use in lieu of a required heat detector. 5 Formerly 7272-1591:126 and 7272-1388:186 7-29-10 ma .0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 5 Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division AP' a: P Strobes, Horns, Bells, Chimes United Technologies C '-I- -':-'- I - Field Configurable,,-~~~LE~RT - Ceiling Strobes . jW -,~' Genesis Series One or more patents pending. - FC MEA C E 7125-1657: 0219 S5389 S Overview Genesis life safety and mass notification/emergency communica- tions (ECS/MNS) ceiling strobes are small, compact, and attractive visible emergency signaling devices. Protruding no more than 1.6" (41 mm) from the ceiling, Genesis strobes blend with any decor. Thanks to patented breakthrough technology, EDWARDS Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required "cross" pattern, significantly exceeding UL-1 971 and ULC-5526 light distribution requirements. Depending on the model, clear lens Genesis ceiling strobes fea- ture 15 to 95, or 95 to 177 candela output (see ordering informa- tion), which is selectable with a conveniently-located switch. The candela output setting remains clearly visible even after final instal- lation, yet it is locked in place to prevent unauthorized movement after installation. Genesis ECS/MNS appliances offer emergency signaling with clear or amber lenses and with optional ALERT housing labels. They are ideal for applications that require differentiation between life safety and mass notification alerts. Standard Features Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 Cd clear strobe lens models available - Switch settings remain visible even after the unit is installed ECS/MNS models available - 13/26/65/82 and 82/100/130/155 (1971 equivalent) amber lens models available Unique low-profile design - 30 per cent slimmer profile than comparable signals - Attractive appearance - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - #18 to #12 AWG terminals - ideal for long runs or existing wing Unparalleled performance - Exclusive FullLight strobe technology produces the industry's most even light distribution - Precision timing electronics meet tough synchronizing standards for strobes - Low current draw minimizes system overhead Approved for public and private mode applications - UL 1971-listed as signaling devices for the hearing impaired - UL 1638-listed as protective visual signaling appliances - UL/ULC listed for ceiling or wall use ~-7 Page lof4 DATA SHEET E850010557 Not to be used for instailaton purpose.-. Issue 1 Application Genesis strobes are UL 1971 or 1638 listed for indoor use. Prevailing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. Synchronization for multiple strobe lights in a single field of view is required. ECS/MNS Applications Genesis ECS/MNS appliances bring the same high-performance life safety features and unobtrusive design to mass notification applica- tions. Available as standard units with clear or amber lenses with optional ALERT markings, thy are ideal for applications that require differentiation between life safety and ECS/MNS signals. Units are also available (special order) with red, blue or green lenses. Installation All models are intended for indoor applications only. Strobes mount to any flush North-American 4" square electrical box, 21/8" (54 mm) deep. Genesis ceiling strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Strobes are interconnected with a single pair of wires as shown below. Dimensions 6.8"dia •1 . I. (173 mm) H 1.0" I (25 mm) 0.60"(15 mm) Light output (effective cd) Percent of UL rating versus angle - Percentage of rated Output - 95. .5. Horizontal and vertical Outputs reflect the same pattern. Field Configuration Depending on the model, Genesis ceiling speaker-strobes have multi-candela output Candela switch (see ordering information). The output / ,- setting is changed by simply opening the device and sliding the switch to the desired setting. The strobe does not have to be removed to change the output setting. / The setting remains visible through a small Indicator window on the front of the device after the cover is closed. WARNING: These defceswiII not operate without electrical power. Asfrresfrequently cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. To listed To next fire alarm appliance, control end-of-line panel MTT 7_1 T or return to control II equipment S Page 2 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue I Light output setting, high output models or "1 or "C" "150" or "B" "1 77 or "A" RMS RMS RMS RMS 333 392 499 551 259 303 378 429 212 245 306 342 155 180 211 236 484 570 673 724 380 438 537 604 318 361 434 484 245 269 308 338 Current Draw Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. Light outi setting, standard models Light output setting, high output models - UL 11511or "30" or "C" 117511 or or 'IN 419511 or "D" 5" or "C"'150"or tI77 or Rating [ RMS RMS RMS RMS F!L RMS RMS RMS RMS 16 Vdc 109 151 281 318 330 392 502 565 16Vfwr 131 194 379 437 432 518 643 693 Typical I Light output setting, standard models 9115" or "D" 9130" or "C" 4175" or "B" "95" or "A" Current RMS RMS RMS RMS 16 Vdc 94 140 273 325 20 Vdc 74 108 205 244 24 Vdc co L6J8 L9 J4 33 Vdc 48 70 124 139 16Vfwr 126 187 368 403 20Vfwr 108 156 281 333 24Vfwr 97 139 240 270 33Vfwr 89 119 197 214 Current values are shown in mA. Specifications Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Red and white models Housing available. Lens Optical grade polycarbonate (clear). Flush mount to North American 4-inch square electrical box, 2-1/8 (54 mm) inches deep. No extension ring required. Mounting Suitable for indoor wall or ceilinci aoolications. Wire Connections Screw terminals: #18 to #12 AWG (0.75 mm2 to 2.5 mml wire size. Operating Voltage Regulated 16 to 33 Vdc, 16 to 33 Vfwr. Operating environment Indoor: 32-120° F (0-49° C) ambient temperature; 0-93% relative humidity. Meets or exceeds year 2004 UL requirements for standards UL1 638 and UL1 971 and Canadian requirements for Agency listings/approvals standards CAN/ULC S526-02 and CAN/ULC S524-01. All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA, FM. Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (GC-VM) and 95/115/150/177 cd (GC-VMH) Strobe operating voltage GC-VM series strobes: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc F\NR. GC-VM series strobes: one flash per second synchronized with optional G M Genesis Signal Master indefinitely within 10 Strobe flash rate milliseconds. Temporal setting (private mode only): synchronized to temporal output of Genesis audible signals on same circuit. Meets or exceeds UL 1971 requirements. Maximum allowed resistance between any two devices is 20 Ohms. Refer Synchronization to specifications for the synchronization control module, this strobe, and the control panel to determine allowed wire resistance. SIGA-CC1S, SIGA-MCC1S, SIGA-CC2A, SIGA-MCC2A, G1M-RM Synchronization Sources BPS6A, BPS1 OA, APS6A, APS1 OA, iO64, 0500, Fireshield Plus 3, 5 and 10 zone. Add G1 M for G1-CVM &G1 -HDVM devices only. C Page 3 of 4 DATA SHEET E85001-0557 Not to be used for Installation purposes. Issue 1 S Ordering Information Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. FE ' . :rrr: i, f:EiErT Model Housing 1 Marking Lens I Strobe Ship Wt. Life safety Anoliances (c/vv runnina man icon screen orinted on housina GC-VM White None Selectable 15, 30, 75, or 95 cd Clear Selectable high output 95, 115, 150, or 177 Cd 1.8 lb. (0.82 kg.) White FIRE" GCFR-VM Red 'FIRE" GC-VMH White None GCF-VMH White "FIRE" ECS/MNS Apoliances (no runninci man icon on housing) GCWA-VMA J White j "Alert" Amber Selectable A, B. C, D 1.8 lb. (0.82 kg.) GCWA-VMC Clear Amber GCWN-VMA None ______ GCWN-VMC Clear G CWA-VMHA I "Alert" Amber Clear Selectable high output Amber A, B, C or D I Clear GCWA-VMHC GCWN-VMHA None GCWN-VMHC Units with red, blue or green lenses are available as a special order. Contact customer service for details. Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. S 9 Page 4of4 E850010557 c br r Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7125-1657:0219) Page 1 of 1 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models GC-VM,(GCF-VM) GCFR-VM, GC-VMH, GCF-VMH, GCWAVMC*, GCWNVMC*, GCWAVMHC* and GCWNVMHC* multiple candela synchronizable strobe lights. The lights are only considered synchronized when used in conjunction with listed Model G1M-RM (CSFM Listing No. 7300-1657:201) sync module, which may employ Model SIGA-CC1S (CSFM Listing No. 7300-1657:121)Auto Sync Output Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VdcNfwr GC candela: 15cd, 30cd, 75cd, or 95cd H candela: 95cd, 115cd, 150cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only, mounted on a wall or a ceiling. MARKING: Listee's name, model number, electrical/candela rating, and UL label. S APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7125-1591:219 7-29-10 ma * This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Technologies 1L4(4==A United -. : Strobes, Horns, Bells, Chimes Field Configurable One or more patents pending. Ceiling Horn -Strobes Genesis Series / M_EA FC 0 @ C ( 7300-1657: 0202 S218 S Overview Genesis ceiling horn-strobes are small, compact, and attractive audible-visible emergency signaling devices. Protruding no more than 1.6" (41 mm), Genesis horn-strobes blend with any decor. Thanks to patented breakthrough technology, EDWARDS Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required "cross" pattern. Depending on the model, Genesis horn-strobes feature 15 to 95, or 95 to 177 candela output (see ordering information), which is selectable with a conveniently-located switch on the front of the device. The candela output setting is clearly visible even after final installation, yet it remains locked in place to prevent unauthorized movement after installation. Genesis horn-strobes feature textured housings in architecturally neu- tral white or eye-catching fire alarm red. An ingenious iconographic symbol indicates the purpose of the device. This universal symbol is code-compliant and is easily recognized by all building occu- pants regardless of what language they speak. Models with "FIRE" markings are also available. Standard Features Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 cd models available - Switch settings remain visible even after the unit is installed - Low/high dB settings Unique low-profile design - 30 per cent slimmer profile than comparable signals - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - Pre-assembled with captive hardware - no loose pieces - #18 to #12 AWG terminals - ideal for long runs or existing wir- ing Unparalleled performance - Exclusive FullLight strobe technology produces the industry's most even light distribution - Single high-efficiency microprocessor controls both horn and strobe - Low current draw minimizes system overhead - Independent horn control provided over a single pair of wires - Highly regulated in-rush current allows the maximum number of strobes on a circuit - 100 dB peak - multiple frequency tone improves wall penetration Page 1 of 4 DATA SHEET E85001-0559 Not tc be used for Psta titlort pup oordts. Issue 1 Application Genesis strobes are UL 1971-listed for use indoors as ceiling- or wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambi- ent noise conditions exceed 105 dBA (87dBA in Canada), where occupants use hearing protection, and in areas of public accom- modation as defined in the Americans with Disabilities Act (see application notes - USA). Combination horn-strobe signals must be installed in accordance with guidelines established for strobe devices. Strobes Genesis strobes are UL 1971 -listed for use indoors as ceiling- or wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambi- ent noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds other over a two-hour period) when used with a synchronization source. Synchronization is important in order to avoid epileptic sensitivity. NOTE: The flash intensity of some visible signals may not be adequate to alert or waken occupants in the protected area. Research indicates that the intensity of strobe needed to awaken 90% of sleeping persons is approximately 100 Cd. EDWARDS recommends that strobes in sleeping rooms be rated at at least 110 cd. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, further safeguards such as backup power supplies may be required. Horns Genesis horn output reaches as high as 99 dB (peak) and features a unique multiple frequency tone that results in excel- lent wall penetration and an unmistakable warning of danger. All models may be configured for either coded or non-coded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. The suggested sound pressure level for each signaling zone used with alert or alarm signals is at least 15 dB above the average ambient sound level, or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5 feet (1.5 m) above the floor. The average ambient sound level is, A-weighted sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. Installation and Mounting All models are intended for indoor wall or ceiling applications only. Horn-strobes mount to any flush North-American 4" square electrical box. Genesis ceiling horn-strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. EDWARDS recommends that these fire alarm horn-strobes always be installed in accordance with the latest recognized edition of national and local fire alarm codes. Field Configuration Depending on the model, Genesis horn-strobes may be set for 15 to 95, or 95 to 177 candela output (see ordering information). The output setting is changed by simply opening the device and sliding the switch to the desired setting. The horn-strobe does not have to be removed to change the output setting. The setting remains visible through a small window on the front of the device after the cover is closed. The horn-strobe comes factory set for high dB output. Low dB output may be selected by cuffing a jumper on the circuit board. This reduces the output by about 5 dB. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Horn/strobes are interconnected with a single pair of wires as shown below. Polarity alarm C next ,liance, lof.Iine etum to ontrol apment Note: Strobes must have continuous voltage. S Dimensions 6.8"dia. •1 (173 mm) LIII - 0.60(15nm) Page 2of4 DATA SHEET E850010559 Not to be used for installation purposes. Issue 1 GC-HDVM Temporal Horn-strobe: Low dB Setting Typical - 15 cd 30 cd 75 cd 95 cd Current RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 108 91 149 139 275 269 327 322 20 Vdc 87 75 120 113 214 209 250 245 24 Vdc 76 66 103 97 180 175 205 201 33 Vdc 64 57 85 80 138 135 153 150 16Vfwr 141 76 204 118 384 239 418 265 20Vfwr 127 65 176 95 312 181 371 214 24Vfwr 118 60 162 82 262 149 301 171 33Vfwr 127 56 155 73 229 118 249 129 Light output - (effective cd) Percent of UL rating versus angle P., C1O1tLP.t, '5. Current Draw GC-HDVM Temporal Horn-strobe: High UL 15 cd 30 cd Rating RMS RMS dB Setting 75cd RMS 95 cd RMS GC-HDVMH High cd Temporal Horn-strobe: High dB Setting 95 cd 115 cci 150 cd 177d RMS RMS RMS RMS 16 Vdc 147 190 316 372 341 399 506 570 16Vfwr 189 253 417 451 487 578 670 711 GC-HDVM Temporal Horn-strobe: High dB Setting GC-HDVMH High cd Temporal Horn-strobe: High dB Setting Typical 15 cd 30 cd 75 cd 95 cd 95 cd 115 cd 150 cd 177 cd Current RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 111 95 152 143 281 276 333 328 324 322 377 374 477 474 554 551 20 Vdc 91 80 124 117 219 214 257 251 258 256 299 296 369 366 417 414 24 Vdc CO 71 (i) 101 180 1) 207 220 217 252 249 304 301 341 338 33 Vdc 69 62 89 84 144 140 160 156 172 169 188 185 223 220 244 241 16Vfwr 153 81 218 123 388 240 420 268 463 265 535 312 665 400 718 442 20Vfwr 141 70 190 100 325 188 378 219 392 211 439 240 517 287 587 334 24Vfwr 135 64 176 90 280 154 310 180 346 179 382 212 458 246 498 271 33Vfwr 139 61 167 80 241 122 254 133 296 142 323 152 358 178 387 194 GC-HDVMH High cd Temporal Horn-strobe: Low dB Setting 95cd 115 Cd 150 cd 177 cd RMS Mean RMS Mean RMS Mean RMS Mean 317 315 378 376 480 477 544 542 252 250 292 290 364 362 414 411 212 211 245 243 297 295 334 332 159 157 181 179 215 213 234 232 461 265 521 305 656 396 705 Z-2 - 381 208 437 242 508 285 576 326 335 172 370 195 440 235 485 264 285 134 308 149 349 169 373 186 Notes and Comments Current values are shown in mA. UL Nameplate Rating can vary from Typical Current due to measurement methods and instruments used. EDWARDS recommends using the Typical Current for system design including NAC and Power Supply loading and voltage drop calculations. Use the Vdc RMS current ratings for filtered power supply and battery AH calculations. Use the Vtwr RMS current ratings for unfiltered power supply calculations. Fuses, circuit breakers and other overcurrent protection devices are typically rated for current in RMS values. Most of these devices operate based upon the heating affect of the current flowing through the device. The RMS current (not the mean current) determines the heating affect and therefore, the trip and hold threshold for those devices. Our industry has used mean currents over the years. However, UL will direct the industry to use the 2004 RMS values in the future. S dBA output High dB Setting UL464 Average Peak Temporal Steady Temporal! Steady Temporal/ Steady 16 Vdc; 79.8 83.2 90.6 93.6 24 Vdc 83.3 85.4 93.6 96.6 33 Vdc 85 87.8 95.7 98.7 Low dB Setting UL464 Average Peak Temporal Steady - Temporal! Steady _ Temporal! Steady 16 Vdc 75 79.3 86.3 88.7 24 Vdc 78 83 88.8 92.4 33 Vdc 80.9 85.9 91.8 95.1 Notes 1. All values shown are dBA measured at 10 feet (3.01 m); 2. UL464 values measured in reverberation room; 3. Average and Peak values are measured in anechoic cham- ber. Page 3 of 4 DATA SHEET E85001-0559 Not to be used for installation purposes. Issue I S Specifications V cb,v4R D S Housing Textured LW stabilized, color impregnated engineered plastic. Exceeds 94V- 0 UL flammability rating. Red and white models available. Lens Optical grade polycarbonate (clear) LIFE SAFETY & INCIDENT MANAGEMENT Mounting North-American 4" square box, 2 1/8(54 mm) deep (indoor wall or ceiling applications only). Contact US... Wire connections Screw terminals: single input for both horn and strobe. #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size Email: edwards.fire@fs.utc.com Web: Edwards-fire.com Operating environment Indoor: 32-120°F (0-49°C) ambient temperature. 93% relative humidity Meets or exceeds ULC-5525 & ULC-S526, year 2004 UL EDWARDS is UTC brand. Agency listings/approvals requirements for standards UL1 638 and UL1 971, and complies 1016 Corporate Park Drive with UL1 480. All horn-strobes comply with ADA Code of Federal Mebane, NC 27302 Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA, FM. GC-HDVM series temporal-tone horn-strobes: non-coded, filtered 2016 United Technologies Corporation. Operating voltage 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded (audible NAC only) All rights reserved, when used with optional Gi M Genesis Signal Master) Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (GC- HDVM) and 95/115/150/177 cd (GC-HDVMH) GC-HDVM series temporal-tone horn-strobes: one flash per second synchronized with optional Gi M Genesis Signal Master indefinitely Strobe flash rate within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without Gi M Genesis Signal Master) Temporal setting (private mode only): synchronized to temporal output of horns on same circuit Synchronization Sources G1M-RM, SIGA-CC1S, SIGA-MCC1S, BPS6A, BPS10A GC-HDVM series temporal-tone horn-strobes: temporal rate synchronized with optional Gi M Genesis Signal Master indefinitely Horn pulse rate within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without 01 M Genesis Signal Master) S ½ sec ON, 1/2 sec OFF, 1/2 sec ON, 1/2 sec OFF, 1/2 sec ON, 1½ sec Temporal audible pattern OFF, then repeat cycle Ordering Information Catalog Housing Marking Description Number Color GC-HDVM White None Genesis Ceiling/Wall Horn-Strobe (GCF-HDVMj White ::FIRE" with selectable 15, 30, 75, or 95 cd output 0.82 GCFR-HDVM Red "FIRE" (1.8) GC-HDVMH White None Genesis Ceiling/Wall Horn-Strobe GCF-HDVMH White "FIRE" with selectable 95, 115, 150, or 177 cd output Accessories 01 M-RM Genesis Signal Master - Remote Mount (1-gang) 0.2 0.5 SIGA-CC1S Intelligent Synchronization Output Module (2-gang) In 0Q1 SIGA-MCC1 0.18S Intelligent Synchronization Output Module (Plug-in UIO) (0.08) White Field Configurable Ceiling Horn-Strobes may be ordered with or without optional 'FIRE' marking. Red Horn-Strobes come with 'FIRE" marking. S Page 4 of 4 DATA SHEET E85001-0559 Not to be used for Installation purposes. Issue 1 Ship Wt. lbs CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7125-1657:00 Page 1 of 1 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models "EST' GI-HV15, -HV30, -HV60, -HV-75, G1-HOV15, -HOV30, -HOV60, -HOV75, -HOV110, GIF-HOV15, -HOV30, -HOV60, -H0V75, -HOV110, GIRF-HOV15, -HOV30, -HOV60, -H0V75, -HOV110, G1-HDVM, G1R-HDVM, GIF-HDVM, G1RF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCFR-HDVM, GCF-HDVMH, G1-HDV1575, G1 R-HDV1575, G1 F-HDV1575, and Gi RF-HDV1575 horn/strobes with or without suffixes -R and -F. Models with HO as part of the model number are a high audible output version of the standard output model. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 24-30 Vdc 16-33VdcNfwr -Models G1-HDVM, G1R-HDVM, G1F-HDVM, G1RF-HDVM, GC-HDVM, GC-HDVMH, (GCF-HDVM' GCFR-HDVM, GCF-HDVMH, G1-HDV1575, Gi R-HDV1575, G1F-HDV1575, G1RF-HDV1575 Candela: 15cd, 30cd, 60cd, 75cd, 110cd 15-95 multi-cd - Models GC-HDVM, GCF-HDVM, GCFR-HVDM 95-177 multi-cd-Models GC-HDVMH, GCF-HDVMH 15/75cd -Models G1-HDV1575, G1 R-HDV1575, GI F-HDV1575, G1 RF-HDV1575 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horns and horn/strobe lights for use with separately listed compatible fire alarm control units. Suitable for use with Audible Signal Appliances (CSFM Listing No. 7135-1657:230). For indoor use and wall mount only. Models GC-HDVM, *GCHDVMH GCFR-HDVM, GCF-HDVM and *GCF-HDVMH for ceiling or wall mount. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Formerly 7125-1591:202 REV 08-20-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct " operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Strobes, Horns, Bells, Chimes V 5ki fA.1 rr r:T z.':/ Jlr:.:n.T Outdoor Rated Horns and L Horn-Strobes Genesis WG4 Series Overview Standard Features Genesis WG4 Series horns and horn-strobe appliances are among • Outdoor and indoor rated the most versatile emergency appliances of their kind. Rated for • Low-profile design w indoor or outdoor use, they are suitable for a wide range of wet and harsh environments with a listed operating temperature range • Wall or ceiling mount of as low as -40 °F to as high as 151 °F (-40 °C to 66 °C). • Room-side wiring accepts 18 to 12 AWG (0.75 to 2.5 mm2) Field-configurable light and sound output settings add to their on- • Wide operating temperature range site flexibility, while optional FIRE markings make them ideal for fire alarm applications. • Field-selectable settings These appliances are suitable for indoor and outdoor applications, and are ideal for challenging conditions such as parking garages and process areas. They are available for mounting on the ceiling or the wall, and thanks to an ingenious optional full backplane sealing gasket, can be installed to recessed (in-the-pour/block) electrical boxes. WG4 notification appliances also mount to suit- able surface boxes. Optional color-matched trim skirts provide a clean, finished appearance. All appliance wiring is accomplished room-side for easy installation. WG4 Series appliances feature an efficient and powerful piezo sounder. The multi-candela strobes are available with clear lenses in two output categories - standard and high-output. They are precision-timed to meet UL 1971 synchronization standards, and field-configurable for one of four candela intensities. Candela settings are viewable even after installation through an innovative sealed viewport display. Fully-compatible with Genesis synchronization protocols Standard and high-output strobe intensities Horn only and horn-strobe options Page 1 of 4 DATA SHEET E85001-0628 Not to 0€ used fc pt-:tcn purposes. Issue 1 Front cc 0 00' Wire slot Application Horns Genesis horn output reaches as high as 97 dBA in accordance with UL 464 (104 dBA in accordance with ULC-S525) and features a unique frequency tone that results in excellent sound penetration and an unmistakable warning of danger. Horns may be configured for either coded or non-coded notification circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. The suggested sound pressure level for each notification zone used with alarm notification appliances is at least 15 dB above the average ambient sound level, or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5 feet (1.5 m) above the floor. The average ambient sound level is A-weighted (fast response) sound pressure measured over a 24-hour period. Doubling the distance from the notification appliance to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materi- als in the space. A 3 dBA difference represents a barely noticeable change in volume. Strobe Application Genesis clear-lensed strobes are UL 1971-listed for use indoors as wall- or ceiling-mounted public-mode notification appliances for the hearing impaired, and UL 1638-listed for outdoor applications. Prevailing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Visible appliance synchronization is required to avoid causing issues with people who have Photosensitive Epilepsy (PSE). Noti- fication appliance synchronization is also generally required when more than two strobe appliances are in the same field of view from any one location. All Genesis strobes meet UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. EDWARDS recommends that these devices always be installed in accordance with the latest recognized edition of national and local codes. Refer to the appropriate codes and standards for mounting height information. Page 2 of 4 Installation and Mounting WG4 Gasket aJ WG4 notification appliances are rated for outdoor use and are suitable for indoor or outdoor applications on walls or ceilings. For surface-mounting in outdoor or wet applications, appliances must be mounted to a 449 or 74347U electrical box. In dry conditions, they are compatible with standard 4-inch square by 11/2-inch deep electri- cal boxes. When using the optional WG4WTS or WG4RTS trim skirt, a 449 or 4-inch square by 2-1/8 deep box must be used. The Genesis WG4 horn and horn-strobe may be wall- or ceiling- mounted, and may be placed in one of four positions: strobe above, strobe below, and strobe to either side. The shallow depth of Gen- esis devices leaves room behind the appliance for extra wiring. Horn volume jumper (JP3) strobe' V pattern jumper (JP4) Horn output: Horns and horn-strobes are factory set for high dB output. Low dB output may be selected by cutting a jumper on the circuit board. This reduces the output by about 5 dB. Strobe pattern: Genesis WG4 horn-strobes are factory set for use as UL 1971 compliant notification appliances for public mode operation. These notification appliances may be configured for temporal flash by cutting JP4 on the circuit board. This battery-saving feature is intended for private mode signaling only. Strobe output: Genesis WG4 horn-strobes may be set for one of four out- put intensities.The output setting is changed by simply opening the device and sliding the switch to the desired setting. The device does not have to be removed to change the output setting. The setting remains visible after the cover is closed through a small window on the front of the device. DATA SHEET E85001-0628 Not to be used for Installation purposes. Issue 1 Field Configuration Horn pattern: Audible output for WG4 horns and horn-strobes is factory set to to sound in a three-pulse temporal pattern. Units may be configured for use with coded systems by cutting a JP1 on the circuit board. This results in a steady output that can be turned on and off (coded) as the system applies and removes power to the notification circuit. A Genesis Signal Master is required when horn-strobe models are con- figured for coded systems. S S Light Output Horizontal Plot .30 .28 .30 40 46 -66 40 -66 Angle 0 lolls Oh ., S S Wiring Field wiring is connected to WG4 notification appliances with terminals that accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Signal In - Signal Out - Signal In + Signal Out + I. -1+ designations indicate the signal polarity required to activate the device. Specifications Horns and Horn-strobes Operating voltage 24 VDC, 24 VFWR nominal Dimensions x H x D) 5.6 x 8.5 x 1.4 in. (142 x 216 x 36mm) Horn tone 3.2 kHz Wire size 12 to 18 AWG (0.75 to 2.50 mm2) Compatible electrical box Outdoor Model 449 or 74347U Indoor 4 in. square by 1.5 in. deep box Operating environment Temperature -40 to 151°F (-40 to 66°C) Relative humidity 0 to 95% noncondensing Compatible Synchronization Sources Horn-strobes Auto-sync Output Modules SlGA-CC1S, SlGA-CC2A, SIGA- MCC1 S, SIGA-MCC2A Genesis Signal Master . Gi M-RM Booster & Auxiliary Power Supplies APS6A, APS1 OA, BPS6A, BPS1 OA Control Panels with Genesis FireShield Plus, iO Series, EST3X Synchronization built-in Sound Output Horns and Horn-strobes (dBA) -- I Volume Setting ______________ 1i6v TT!V 3V UL 464 ULC- IS525 UL 464 ULC- S525 UL 464 ULC- S525 Continuous High 89.7 1 94.0 94.7 99.6 97.4 102.9 Continuous Low 85.4 92.8 89.5 97.2 92.5 98.6 Temporal High 84.2 96.5 90.5 100.5 .93.5 104.2 Temporal Low 81.7 1 90.3 85.4 1 94.2 1 88.1 97.0 dBA = Decibels, A-weighted. UL 464: Sound level output measured in a reverberant room at 10 ft. (3.05m). cAN/uLc-s525: Sound level output measured in an anechoic room at lOft (3.05m). Percentage of rated output Standard Candela Horn-strobes StrobeSwftchPosition Standard/rating D C B A UL 1971 Indoor 15 cd (9ççl) 70 cd 87 cd UL 1638 Outdoor @-35°C 6 c 12 cd 28 cd 35 cd CAN/ULC-5526 Outdoor © -40°C 1 cd 3 cd 8 cd 10 cd High Candela Horn-strobes Strobe Switch Position Standard/rating D C B A UL 1971 Indoor 102cd 123cd 147cd 161cd UL 1638 Outdoor ©-35°C 41cd 50 cd 60 cd 65 cd CAN/ULC-5526 Outdoor © -40°C 11 cd 14 cd 17 cd 18 cd Operating Current (UL specifies current ratings at 16 volts) - Standard Candela Horn-strobes in RMS (mA), continuous Strobe Switch Position Input Voltage D C B A 16 VDC 127 168 297 351 16 VFWR 218 239 393 422 24 VDC. 107 wo 210 238 24 VFWR 190 222 325 356 High Candela Horn-strobes in RMS (mA), continuous F __-S-tro_b"e_S_wftc:h Position Voltage 1 Input ________________________ D C B A 16 VDC 342 408 517 526 16 VFWR 447 502 614 679 24 VDC 240 271 327 365 24 VFWR 390 400 486 540 Horn only models (mA) [ 16VRMS,ciiuous 24V typical Setting High dB Low dB High dB Low dB VDC 69.1 41.2 49.0 32.3 VFWR 135 91.3 99.1 67.1 Page 3 of 4 DATA SHEET E85001-0628,- Not to be used for installation purposes. - Issue I ICE—DWARDS LIFE SAFETY & II4CIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Ordering Information E W'3iI JJ WG48F•H WG4RF-HVMC WG4WF4I WG4WF•HVMC W134RN-H WG4RN-HVMC WG4WH•H WG4WN•HVMC Model Housing Marking Strobe Output Ship Wt. WG4RF-HVMC Red FIRE Selectable standard candela output WFI4VMC) White WG4RN-HVMC Red None White WG4WN-HVMC WG4RF-HVMHC Red FIRE Selectable high candela output 1.5 lbs. (0.68 kg) WG4WF-HVMHC White WG4RN-HVMHC Red None White WG4WN-HVMHC WG4RF-H Red FIRE Horn Only White WG4WF-H White WG4RN-H Red None WG4WN-H Accessories WG4WVS Surface Skirt for Genesis WG4 appliance family, white. WG4RTS Surface Skirt for Genesis WG4 appliance family, red. WG4GSKV Full Body Mounting Gasket for smooth surfaces, WG4 appliance family 74347U Surface mount box, outdoor rated, red 449 Surface mount box, outdoor rated, gray S Page 4of4 DATA SHEET E850010628 Not to be used for installation purposes. Issue 1