Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5927 GEIGER CT; ; FA140145; Permit
City of Carlsbad Fire Alarm Permit Permit No: FA140145 Job Address: 5927 GEIGER CT Permit Type: FALARM Parcel No: 2120701700 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 10/21/2014 Approved: 10/23/2014 Issued: 10/23/2014 Inspector: Project Title: MEANS ENGINEERING INSTALL NEW FIRE ALARM SYSTEM TO MONITOR SPRINKLER SYSTEM AND DUCT SMOKE DETECTORS AND PULL STATION. INSTALL HORN/STORBE AND ANNUNCIATOR AT ENTRY. SYSTE TO BE AUTOMATIC (SPRINKLER SYSTEM) PERMITED UNDER 2010 BLDG CODE. FIRE ALARM IS MONITORED BY CENTRAL STATION. Applicant: RIVER FIRE & SECURITY INC. 8920 ACTIVITY RD STE J SAN DIEGO, CA 858-752-6250 Owner: MEANS FAMILY TRUST 08-08-12 C/O MEANS ENGINEERING CO 6155 CORTE DEL CEDRO CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 478 0 478 0 Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Electrical Primary AC: 120 VRMS @50/60 Hz, 2.7A Total Accessory Load: 2.5A @ 27.4 VDC power-limited [Standby Current: 200 mA) (Alarm Current: 365 mA) Battery Charging Capacity: 7 to 35 AH Battery Size: 7 AH max. allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. Notification Appliance Circuits Two circuits that can be programmed individually as: Notification Circuits: 2.5A per circuit @ 27.4 VDC, power-limited Auxiliary Power Circuits: 2.5A per circuit @ 27.4 VDC, power-limited Indicator Lights Alarm (Red): Flashes when in alarm; solid when alarm silenced Supervisory (Yellow): Flashes when a supervisory condition exists; solid when supervisory silenced Trouble (Yellow): Flashes when a trouble condition exists; solid when trouble silenced Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared Power (Green): Flashes for AC failure; solid when power systems are normal Telephone Requirements: FCC Part 15 & Part 68 approved Jack: RJ31X (two required) Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterfiow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listing; CSFM 170-0559-.144-, MEA 429-92-E Vol XVI Approved Releasing Solenoid Manufacturer Part Number Rating Asco T8210A107 24 VDC, 2.5A Asco 8210G207 24 VDC, 2.5A Ordering Information lFP-50 Intelligent Fire Alarm Control Panel. SBUS Accessories A-1ö) Remote Annunciator. Similar in operation and appearance to FACP annunciator. RA-1000 Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. RA-1000R Remote Annunciator. Four line LCD annunciator with 20 characters per line. Red. 5496 Intelligent Power Module. 6 amp power module that provides four additional power limited notification appliance circuits. 5824 Serial/Parallel Printer Interface Module. Provides one parallel and one RS-232 serial port for connecting a printer to IFP-50. 5880 LED I/O Module. Provides 40 LED outputs, eight normally open dry contacts inputs and one piezo output. 5865-3 & 5865-4 LED Fire Annunciators. Provides 30 programmable LED outputs and a piezo sounder. 5883 Relay Interface Board. Provides 10 general purpose Form C relays. Used with 5880. SD and IDP Devices See the specification sheets listed below for a complete listing of the SD and IDP devices. 350360 SD Devices data sheet 350361 Intelligent Device Protocol (IDP) Devices data sheet Miscellaneous Accessories 5650/5651 Silent Knight Software Suite. Provides programming, upload/download, and event reporting. Order 5650 for PC parallel port compatibility or 5651 for PC USB port compatibility 5670 Silent Knight Software Suite. Provides facility monitoring RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6' D (406 mm W x 254 mm H x 152 mm D) SP-TR Small panel trim ring. Use to flush mount the panel. 16.975" H x 14.630" W. D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 by Honeywell Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical support, please call 800-446-6444. www.farenhyt.com Assembled in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM 0 LISTING SERVICE LISTING No. (7272-05590149) Page 1 of 1 CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: (SILENT KNIGHT 5ECUR1T77550)Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaachoneywell.com DESIGN: (Models IDP-PHOTO) IDPPHOTOR*, IDP-PHOTO-T, lDP-ACCLIMATE, SK-PHOTO, SKPHOTOR*, SK-PHOTO-T and SK-ACCLI MATE(photoelectric typ)smoke detectors. Model IDP-PHOTO-T employs a 1350F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 04000 FPM. Models lDP-PHOTO and lDP-PHOTOR are approved for installations inside System sensor duct housing DNR (OSFM Listing No. 3242-1653:209) and DNRW (OSFM Listing No. 32421653:210)*. Models SK-PHOTO and SK-PHOTOR are approved for installations inside Silent Knight SK-DUCT (OSFM Listing No. 3242-0559:162) and System Sensor DNRW (OSFM Listing No. 32421653:210)* NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0028:0206 Rev. 02-01-10fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 (Listing EKpJrs (June 30, 201 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division IFP-1 000 FACP Qc r.00Q LJ c3r]l) ao RA-1000 $c u RA-1000 RA-1000 Ju• . Up to 8 RA-1000 per system 80-character backlit LCD display (4 lines with 20 characters each) Wiring lengths up to 6000 ft. from the control panel Specifications Approvals Physical NFPA72 Height: 7.4" (18.8 cm) UL Listed; Width: 9.1" (23.1 cm) • CSFM 7170-0559:135; Depth: 1.5" (3.8 cm) MEA 429-92-E Vol. IX; Shipping Weight: 2.8 lbs (1.3 kg) FM Approved Color Ordering Information RA-1000R: Red RA-1000: Gray RA-1 000R Remote Annunciator. Four line LCD annunciator with 20 characters per line. Electrical Red. Operating Voltage: 24 VDC RA-1000 Remote Annunciator. Four line LCD (standby Current: 20 mA m!) annunciator with 20 characters per line. (Alarm Current: 25 mA) Gray. Accessories Wiring Distance: 6,000 max. from FACP (depending on wire 5860TR Red Trim Ring. For surface mounting. gauge and number of devices on the SBUS) 5860TG Gray Trim Ring. For surface mounting. Max Per System: 8 Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C Humidity: 10% - 93% non-condensing D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 by Honeywell Phone: (800) 328-0103, Fax: (203) 484-7118. www.farenhyt.com - Made In the U.S.A. class A Optional Wiring .. ....- .................. ......................................-...... Wiring lOP-Series Detector Mounting Bases Wiring IDP-Series Detector Mounting Bases Specifications* Ordering Information Physical Height: 2.0" (5.0 cm) IDP-Photo Photoelectric Smoke Detector Diameter: 4.1" (10.4 cm) installed in B501 base IDP-Photo-T Photoelectric Smoke Detector with Thermal (135°F) Electrical Operating Voltage: 15-32 VDC Standby Current: 24 VDC](no communication; LED off) 300 pA @ 24 VDC (one communication every 5 sec with LED enabled) (Alarm Current: 6.5 mA @ 24 VDC max (with LED on) Environmental Operating Temperature IDP-Photo: 321 - 120°F (0°C - 49°C) IDP-Photo-T: 320 - 100°F (0°C - 38°C) Humidity: 10% - 93% non-condensing Other Ratings IDP-Photo-T Thermal: Fixed temperature setpoint 135°F (57°C) Velocity: 0 - 4000 fpm (0 - 20 m/sec) (suitable for installation in ducts) lDP-Photo Insect Screen Hole Size: 0.016' (0.41 mm) nominal IDP-PhotoR Photoelectric smoke detector, remote test capable, for use with DNR (N) duct smoke detector Accessories RA100Z Remote LED Annunciator. XR213 Detector Removal Tool. A removal and replacement tool for IDP plug-in detectors. Includes the 155-127-000. M02-04-01 Detector Test Magnet. M02-09-00 Test Magnet with Telescoping Handle. XP4 Extension Pole for XR2B. Extends from 5-15 ft. T55-127-000 Detector Removal Head. BCK-200B Black Detector Kit. For lOP-series detectors. * Unless otherwise noted, specifications apply to IDP-Photo and IDP-Photo-T. This document is not intended to be used for installation purposes. We try to keep our _______________ D SILENT product information up-to-date and accurate. We cannot cover all specific applications or _______________ KNIGHT anticipate all requirements. tJl specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call by Honeywell 800-446-6444. www.farenhyt.com Made In the U.S.A. Other Devices Wiring the IDP-Minimon Specifications Physical Height: 1.3" (3.3 cm) Width: 2.8" (7 cm) Depth: 0.5" (1.3 cm) Shipping Weight: 1.2 oz (37 g) Electrical Operating Voltage: 15 - 32 VDC (jStandby Current: 375 pAlt 600 pA max (communicating, lDC shorted) End-of-Line Resistance: 47K ± Initiating Device Circuit Wiring Resistance: 1,5002 max SLC Loop Resistance: 402 max. Wire Length: 6" mm. Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Ordering Information IDP-Minimon Miniature Monitoring Module This document is not intended to be used for installation purposes. We try to keep our D SILENT product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call by Honeywell 800-446-6444. www.farenhyt.com Made in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 700-0559:01 Page 1 of 1 CATEGORY: pQFIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: (SILENT KNIGH)SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaachoneyweII.com DESIGN: lDP-Relay-6, SK-Relay-6, relay module, IDP-Control-6, SK -Control-6, supervising control module, IDP-Monitor-10, SK-Mon-10, input monitor module, IDP-Zone-6, SK-Zone-6 six zone interface module, lDP-Monitor,Min) lDP-Zone, SK-Monitor, SK-Minimon, SK-Zone monitor modules, IDP-Control, lDP-Relay, SK-Control, SK-Relay, control modules, lDP-Monitor-2, SK-Monitor-2, dual monitor modules,and *IDP..RELAYMON..2 *SK..RELAYMON2 with 2 input/2 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. NOTE: If an external power supply is used for Model SK-Zone-6 and IDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. XLF: 7300-0028:0219 *Rev. 10-25-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 (Listing Expirs (June 30, 201i) Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division 77"+ Class A IN SLC . . + OUT Class B Compatible FACP F 1, ' 114 I F : I a L :i CD ti Ix Wiring IDP-Pull-SA & IDP-Pull-DA Pull Stations Specifications* Physical Height: 5.5" (14 cm) Width: 4" (10.2 cm) Depth: 5.4 oz. (3.7 cm) Housing Material: LEXAN polycarbonate resin Si-Colored LED: Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (NIO) switch which closes upon activation of the pull station Electrical Operating Voltage: 15-32 VDC (Operating Current (LED flashing): 30öjiAj Wire Gauge: Up to 12 AWG (3.1 mm2) Environmental Operating Temperature 320 - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Ordering Information lDP-Pull-SA Single Action Pull Station IDP-Pull-DA Dual Action Pull Station Accessories BG-TR Optional trim ring. SB-I/O Surface backbox, indoor/outdoor. * Unless otherwise noted, specifications apply to IOP-Pull-SA and IDP-Pull-DA. D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications KNIGHT or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472- by Honeywell 1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.farenhyt.com Made In the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 10-0559:0157) Page 1 of 1 CATEGORY: (7150 -- FIREALARM PULL BOXES LISTEE: (SILENT KNIGHT SEC UR1TY7550)Meridian Circle, Maple Grove, MN 55369-4927 Contact Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike. mcisaac@honeywell.com DESIGN: (Model lDP-PULL-SA'manual pull box. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 09-08-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering the test results and/or other data but does not make an independent verification of any claims. staff has reviewed This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing (xpjJ (June 30, 2014) Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division SpectrAlert Advance Dimensions Wall-mount horn strobes SpectrAlert Advance Ordering Information Wall Horn Strobes P2R 2-Wire Horn Strobe, Standard cd, Red P2R-P 2-Wire Horn Strobe, Standard cd, Red, Plain P2R-SP 2-Wire Horn Strobe, Standard cd, Red, 'FUEGO" P2RH 2-Wire Horn Strobe, High cd, Red P2RH-P 2-Wire Horn Strobe, High cd, Red, Plain (2) 2-Wire Horn Strobe, Standard cd, White P2W-P 2-Wire Horn Strobe, Standard cd, White, Plain P2WH 2-Wire Horn Strobe, High cd, White P2WH-P 2-Wire Horn Strobe, High cd, White, Plain P4R 4-Wire Horn Strobe, Standard cd, Red P4R-P 4-Wire Horn Strobe, Standard cd, Red, Plain P4RH 4-Wire Horn Strobe, High cd, Red P4W 4-Wire Horn Strobe, Standard cd, White Wall Strobes SR Strobe, Standard cd, Red SR-P Strobe, Standard cd, Red, Plain SR-SP Strobe, Standard cd, Red, 'FUEGO" Model Description Wall Strobes (cont.) SRH Strobe, High cd. Red SRH-P Strobe, High cd, Red, Plain SRH-SP Strobe, High cd, Red, 'FUEGO" SW Strobe, Standard cd, White SW-P Strobe, Standard cd, White, Plain SWH Strobe, High cd, White SWH-P Strobe, High cd, White, Plain Horns HR Horn, Red HW Horn, White Accessories TR-HS Trim Ring, Wall, Red SBBR Indoor Surface Mount Back Box, Red SBBW Indoor Surface Mount Back Box, White Notes: All -P models have a plain housing (no 'FIRE" marking on cover) All -SP models have "FUEGO" marking on cover 'Standard cd' refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. 'High cd' refers to strobes that include 135, 150, 177, and 185 candela settings. ' VTEIV1 3825 Ohio Avenue • St. Charles, IL 60174 fm cueaiul paidici 1faimaiai, ickath9 the ideal see ol 110/dais 031001. .$ SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 F'ai Sd4iC5CflS Wbi1I och2Ie wjthoi daice. visit syslemleraoicom www.systemsensor.com AVD510201 • 1/14 UL Current Draw Data t'iu Max. iStrobe Current iuDraw zmvi:iii TN1AFi 8-175 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC PAIR Standard Candela Range High Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 135 NA NA 228 207 177 NA NA 281 251 185 NA NA 286 258 Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 150 NA NA 246 220 Coded Low 40 46 52 50 DC Input 15 15/75 15175 30 75 95 110 115 Temporal High 137 147 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 III UMax.1iTi DC Input 16-33 Volts 135 150 Ii Strobe, 177 HighICandela 185 lRange (135-185 cd) FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 Switch Volts Position Sound Pattern dB DC FWR 16-33 Volts DC PAIR 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 Coded Medium 78 78 85 85 90 90 97 98 Coded Low 74 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobes. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0 1 ~88 Page 1 of 1 CATEGORY: 7125— FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: (ystem Sensor) Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart©systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P21RA P2RH and P2WH(j/Strobes)two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix UKfl indicating indoor or outdoor use, or may be followed by suffix "P" for plain housing with no lettering. "K° suffix models are suitable for outdoor applications at temperatures from -40°F to +151 OF (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SAWBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 (Listing Expires) CJune 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Specifications, Duct Smoke Detector Accessories Voltage Regulated 24 VDC Power Requirements Alarm LED: 2.8 to 32 VDC, 12 mA max. Operating Voltage 161033 VDC Total Current: 105 mA max. Maximum Alarm Current 30 mA Test Switch 10 VA @32 VDC Temperature Range 0°C to 49°C (32°F to 120°F) Reset Switch 10 VA @ 32 VDC Relative Humidity 10 to 93% non-condensing Alarm Response Time 40 seconds max. Wire Gauge 12 to 18 AWG Temperature Range —10°C to 60°C (14°F to 140°F) Dimensions 4.6H x 2.9W .45D Relative Humidity 95% non-condensing MHR/MHW SpectrAlere Advance Mini-Horns Wire Gauge 14 to 18 AWG Voltage Regulated 12 DC or FWR (Full Wave Dimensions 4.&H x 2.90W x 1.4D Rectified) or Regulated 24 VDC or FWR RTS151 KEY RemoteTest Station with Key Sounder Current Draw 22 mA RMS max. at 810 17.5 Volts DC Power Requirements Power LED (Green): 141035 VDC, 29 mA RMS max. at 16 to 33 Volts DC 12 mA max. Temperature Range 0°C to 49°C (32°F to 120°F) Alarm LED (Red): 2.81032 VDC, Humidity Range 10 to 93% non-condensing 12 mA max. Nominal Sounder 3 kHz Total Current: 105 mA max. Frequency Alarm Response Time 40 seconds max. Wire Gauge 12 to 18 AWG Temperature Range —10°C to 60°C (14°F to 140°F) Dimensions 4.6-H x 2.9w x 0.45D Relative Humidity 95% non-condensing _________________ Remote Annunciator ________________________ Wire Gauge 14 to 18 AWG Voltage Range Conventional System: 3.1 to32VDC Dimensions 4.6-H x 2.75W x 1.8D Intelligent System: 181032 VDC RTS2 and RTS2-AOS Multi -signaling Accessory Maximum Alarm Current 10 mA Voltage 201029 VDC Dimensions 4.6 H x 2.8VV x 1.3D Power Requirements Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe: 30 mA max. Alarm with strobe: 55 mA max. Sounder 85 dBA at ten feet Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 22 AWG Dimensions 4.8W x 5.3H x 1.6D For the very latest product specifications and listing information, please visit the System Sensor Web site at www.systemsensor.com. SMOKE H RTS2-AOS UL S2522 RTS151 UL S4011 APA151 UL S4011 fl:1 RA100Z UL S2522 MHW UL S4011 MHR UL S4011 AIDS SYSTEFL4 3825 Ohio Avenue • St. Charles, IL 60174 CM13 System SCSOr. Phone: 800-SENSOR2 • Fax: 630-377-6495 Prodtt ecicatn SubjCt to Charge wod roc. Vsorc SE,vsoR Io cmu podi momrnl, ncMdg the thiesi essionol Ns data sheet www.systemsensor.com HV0S20202 • 8/13 • CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 0 LISTING SERVICE LISTING No. 17300-1653:0212) Page 1 of 1 CATEGORY: - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: (System Sensor) Unincorporated Div of Honeywell Intl Inc.3825 Ohio Aye, St. Charles, IL 60174 0 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: tnsh.linhart@systemsensor.com DESIGN: Models RTS151,[RTS151KEY)and RA100Z Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Refer to the installation manuals. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 04-03-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 (June 30,015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division