HomeMy WebLinkAbout2525 EL CAMINO REAL; 243; FPC2018-0369; PermitPrint Date: 10/20/2021 Job Address: 2525 EL CAMINO REAL, # 243, Permit Type: FIRE-Construction Commercial Parcel U: 1563020900 Valuation: $56,602.67 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: PERMIT REPORT tity of Carlsbad Permit No: FPC2018-0369 CARLSBAD, CA 92008-1209 Status: Closed - Finaled Work Class: Fire Sprinklers Track U: Applied: 11/14/2018 Lot #: Issued: 11/27/2018 Project U: Finaled Close Out: 09/16/2021 Plan U: Construction Type: Orig. Plan Check U: - Inspector: Plan Check U: Final Inspection: Project Title: Description: SUNGLASS HUT -SPRINKLER TI (16 HEADS) Applicant: FPContractor: RCM FIRE PROTECTION INC RCM FIRE PROTECTION INC JOSH LLOYD 350 ENTERPRISE PL 9155 ARCHIBALD AVE, #906 TRACY, CA 95304-1610 RANCHO CUCAMONGA, CA 91730-5206 (209) 833-8228 (909) 527-4420 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov 9155 ARCHIBALD AVE, SUITE 906 • RANCHO CUCAMONGA, CA 91730 • 909-527-4420 • RCMFIRE.COM • LIC# 793205 C16. MATERIAL SUBMITTAL FOR SUNGLASS HUT 2325 EL CAM INO REAL SPACE 243 CARLSBAD, CA 92008 PREPARED BY: WES PETERSON FPC20I8-0369 2525 EL CAMINO REAL #243 SUNGLASS HUT - SPRINKLER TI (16 HEADS) 1563020900 11114/2018 FPC20I8-0369 ALL MATERIALS PROVIDED FOR THIS PROJECT WILL BE NEW, UL LISTED AND/OR FM APPROVED. IN CASES OF UNAVAILABILITY, ANY SUBSTITUTIONS WILL BE AN EQUAL OR BETTER PRODUCT. 9155 ARCHIBALD AVE, SUITE 906 • RANCHO CUCAMONGA, CA 91730 • 909-527-4420 • RCMFIRE.COM • LIC# 793205 C16. INDEX OF MATERIALS SECTION 1 - PIPE AND FITTINGS ___________________________ 2 Bull Moose SchedlO-40 ________________________________________ 3 Anvil DI 90 4 Anvil Di cap 5 Anvil Dl RC 6 Anvil DI tee 7 SECTION 2- SPRINKLER HEADS ____________________________ 8 Tyco TY3231 QR semi-recessed pendant 9 Tyco TY3531 QR concealed pendant 16 SECTION 3- HANGERS AND BRACING _______________________ 20 Tolco side beam fig58 21 Sammys Wood Vertical __________________________________________ 22 END OF SUBMITTAL ____________________________________ 23 ALL MATERIALS PROVIDED FOR THIS PROJECT WILL BE NEW, UL LISTED AND/OR FM APPROVED. IN CASES OF UNAVAILABILITY, ANY SUBSTITUTIONS WILL BE AN EQUAL OR BETTER PRODUCT. 9155 ARCHIBALD AVE, SUITE 906 • RANCHO CUCAMONGA, CA 91730 • 909-527-4420 • RCMFIRE.COM • LIC# 793205 C16. PIPE &FITTINGS SPECIFICATIONS ALL MATERIALS PROVIDED FOR THIS PROJECT WILL BE NEW, UL LISTED AND/OR FM APPROVED. IN CASES OF UNAVAILABILITY, ANY SUBSTITUTIONS WILL BE AN EQUAL OR BETTER PRODUCT. SECTION 1 - PIPE AND FITTINGS 2 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Bull Moose Tube's Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot-dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. Schedule 10 Pipe T - 1 1.315 1.097 1.41 lbs/ft 91 1 1/4 1.660 1.442 1.81 lbs/ft 61 11/2 1.900 1.682 2.09 lbs/ft 61 2 2.375 2.157 2.64 lbs/ft 37 21/2 2.875 2.635 3.53 lbs/ft 30 3 3.500 3.260 4.34 lbs/ft 19 4 4.500 4.260 5.62 lbs/ft 19 Schedule 40 Pipe - () (WI) II 1 1 1.315 1.049 1.68 lbs/ft 70 11/4 1 . 1.660 1.380 2.27 lbs/ft 51 11/2 1.900 1.610 2.72 lbs/ft 44 2 2.375 2.067 3.66 lbs/ft 30 21/2 2.875 2.468 5.80 lbs/ft 30 3 3.500 3.068 7.58 lbs/ft 19 4 4.500 4.260 10.80 lbs/ft 19 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. 1819 Clarkson Road For additional information, 6 Chesterfield, MO 63017 contact your salesperson C us @ C WED ______ (800) 325-4467 today at (800) 325-4467 or ELA.L. IVOO TUBE CCINY FAX: (636) 537-2645 (636) 537-2600 in the USA, ______ www.bullrnoosetube.com or from Canada ACAFfllOcompany e-mail: sales@bullmoosetube corn call (800) 882-4666 £PPOVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 Bull Moose Sched10-40 3 DUCTILE IRON THREADED FITTINGS (~)ANViU FIG, 3201 900 Elbow DL us4 3 ThD APPROVED r,pproeiv Details and Umtiaflens, ebsita at %ntew.anvlflntJ.com or Anvil* Sales Representative. FIGURE 3201 .Iui ELBOW Nominal Size Maximum Working Pressure* Dimension A Approx. Wt. Each In. (mm) PSI (kPo) In. (mm) Lbs. (kg) 1 500 1.50 0.62 20 3450 38.10 0.28 11/4 500 1.75 0.90 32 3450 44.45 0.41 1/2 500 1.94 1.20 40 3450 49.276 0.54 2 500 2.25 1.85 MATERIAL SPECIFICATIONS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC listed and FM Approved. 50 3450 51.15 0.84 NOTICE: Ductile iron fittings hove higher tensile strength then that of steel pipe. A - Working Pressure Ratings are for reference only and based on 5th. 40 pipe. For the Therefore, over tightening can cause domage to pipe threads which may cause latest UL/UIC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or leakage. Ductile iron fittings should be tightened approximately three turns beyond contact your local Anvil Representative, bond tight, but no more than four turns. PROJECT INFORMATION APPROVAL STAMP Project: []Approved Address: []Approved as noted Contractor: 0 Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: AE~~ DUCTILE IRON THREADED FITTINGS FIG. 3224 Cap P1 IGURE 32240 Nominal Size Maximum Working PressureA Dimension A Approx. Wt. Each In. (mm) PS! ON In. (mm) Lk (kg) 1 500 1.16 0.32 25 3450 29.46 0.15 in 500 1.28 0.43 32 3450 32.51 0.20 1/7 500 1.33 0.60 40 3450 33.18 0.21 2 500 1.45 0.91 50 1 3450 1 36.83 1 0.41 A - Woricing Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest LJL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. LISTED APPROVED For Usllngsftippsoval Details and Umtations, vioti our websita at eswe.anviilntJ.cem or contact an Anvil* Sales Representative. Dimensions: ASME 316.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME 31.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening con cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. Project: []Approved Address: [-]Approved as noted Contractor: 0 Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: cap AE~~ DUCTILE IRON THREADED FITTINGS FIG. 3221R Reducing Coupling c®US USTED APPROVED For ListIngs/Approval Details and UmtatIons, visit our websile at vaaw.anviflnfl.com or rented an Anvil Sales RepresentatIve. FIGURE 'J44I:U REDUCING Zs'.1UJJIIk1[c Nominal Size Maximum Working PressureA Dimension A Approx. Wt. Each In. (mm) PSI (kPo) In. (mm) Lbs. (kg) lx ½ 500 1.69 0.39 25x 15 3450 42.92 0.18 1 xY4 500 1.69 0.53 25x20 3450 42.92 0.24 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. M AT ERIAL Si I'll ['lfi IL.] ' I. Dimensions: ASME Bi 6.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME 81.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT INFORMATION APPROVAL STAMP Project: [JApproved Address: JApproved as noted Contractor: D Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: < 2sF/RNv—'L DUCTILE IRON THREADED FITTINGS ®N1I FIG. 3205 Straight Tee LISTED APPROVED :ingsfAppmval Details and Umliations, our website at www.anvltntI.com or act an Anvil6 Sales Representative. [iFIGURE 1IcNu1..1 I:1[eI:li TEE Nominal Size Maximum Working PressureA Dimension A Approx. WI. Ea(h In. (mm) PSI (kPo) in. (mm) L. (kg) 1 500 1.50 0.85 25 3450 38.10 0.39 1¼ 500 1.75 1.22 32 3450 44.45 0.55 1'/2 500 1.94 1.55 40 3450 49.27 0.70 2 500 2.25 2.45 50 1 3450 1 57.15 1 LII A - Working Pressure Ratings are for reference only and based on 5ch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.cam or contact your local Anvil Representative. Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron linings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT INFORMATION APPROVAL STAMP l Project: []Approved Address: ) Approved as noted Contractor: 0 Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: ilil .44 tee 9155 ARCHIBALD AVE, SUITE 906 • RANCHO CUCAMONGA, CA 91730 • 909-527-4420 • RCMFIRE.COM • LIC# 793205 C16. SPRINKLER HEADS ALL MATERIALS PROVIDED FOR THIS PROJECT WILL BE NEW, UL LISTED AND/OR FM APPROVED. IN CASES OF UNAVAILABILITY, ANY SUBSTITUTIONS WILL BE AN EQUAL OR BETTER PRODUCT. SECTION 2- SPRINKLER HEADS 8 tqca Fire Protection Products Worldwide Contacts www.tyco-fire.com * Series TY-FRB - 2,8,f 4,2,f 56, and 80 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pen- dent, and Recessed Pendent Sprin- klers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a A two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series TY- FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356, and Sprinkler Guards are detailed in Tech- nical Data Sheet TFP780. It)lt The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. Sprinkler Identification Number (SIN) TY1131: Upright 2.8K, 1/2"NPT Pendent 2.8K, 1/2- NPT Upright 4.2K, 1/2- NPT Pendent 4.2K, 1/2" NPT Upright 5.6K,1/2"NPT Pendent 5.61K, 112 NPT Upright 8.01K, 3/4- NPT Pendent 8.01K, 3/4" NPT TY4831: Upright 8.01K, 1/2- NPT 1Y4931: Pendent 8.0K, 1/2- NPT TFPI7I IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 OCTOBER 2013 Tyco 1Y3231 QR semi-recessed pendant The owner is responsible for maintain- TY1231: ing their fire protection system and TY2131: devices in proper operating co n. 1Y2231: The installing contractor or sprin TY3131: manufacturer shou" - 1Y3231: any questions. TY4131: 1Y4231: * Temperature rating is indicated on Deflector. ** Pipe thread connections per ISO 7-1 can be provided on special request. 1/2' NPT UPRIGHT 2-7/8" (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION TFPI7I Page 3 of 10 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* ESCUTCHEON PLATE SEATING SURFACE 7/16" i :11,1 mm) JOMINAL L1/2' I6n MAKE-IN mm) 2-3/16 (55,6mm) F WRENCH STYLE 10 or 20 FLATS RECESSED PENDENT ESCUTCHEON FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT ('rf3131) AND PENDENT (TV323I) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector, special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE $ 1/2" (12,7 mm) NOMINAL _____ (58,7 mm) 2 16 MAKE-IN I 2-1/4" 1-9/16" I mm,/ _ (57,2 (39,7 mm) I 3/4" NPT** I WRENCH STYLE 30 or 40 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT FIGURE 4 QUICK RESPONSE SERIES 1Y-FR8 UPRIGHT (TY4131) AND PENDENT ('TY4231) SPRINKLERS ao K-FACTOR, 3/4 INCH NPT 1-...--- 2-7/8" (73,0 mm) DIA. II CROSS SECTION Tyco 1Y3231 QR semi-recessed pendant 10 rFP171 Page 4 of 10 CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 Button Screw 7/16° /j 3 - Sealing 6 - Deflector * Assembly 4 - Bulb (11,1 mm) / 2-1/4 MAKE-IN Temperature rating is indicated on Deflector. I 1-9/16 NOMINAL (572 mm) * 2 3/16 (55,6 mm) . mm) (39,7 I 5 -•- Pipe thread connections - . I 6 * per ISO 7-1 can be provided on special 1/2' NPT** I WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4631) AND PENDENT (TY4931) SPRINKLERS - &OK-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion-resistant status. Maximum Working Pressure Refer to Table C. Discharge Coefficient K=2.8 GPM/psi112 (40,3 LPM/barl/2) K=4.2 GPM/psi'/2 (60,5 LPM/barl/2) K=5.6 GPM/p511/2 (80,6 LPM/barl/2) K=8.0 GPM/ps1112 (115,2 LPM/barl/2) Temperature Rating Refer to Table and B. Finishes Sprinkler: Refer to Table D. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly.........Beryllium Nickel w/TEFLON Bulb ......................Glass Compression Screw ........ Bronze Deflector...........Copper/Bronze Bushing (K=2.8) ...........Bronze Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pen- dent, and Recessed Pendent Sprinklers are intended for fire protection sys- tems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the require- ments of FM's Loss Prevention Data Sheets): Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applica- ble, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklersmust be installed in accordance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint shold be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft, lbs. (13,4 to 26,8 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series TY-FRB Upright and Pendent Sprinklers The Series TY-FRB Pendent and Upright Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 14). With refer- ence to Figures 1 through 5, apply the W-Type 6 Sprinkler Wrench to the sprin- kler wrench flats. Series TY-FRB Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure Tyco TY3231 QR semi-recessed pendant 11 rFP171 Page 6 of 10 SPRINKLER FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED I SIGNAL*** WHITE LEAD COATED 5.6 1/2" NPT PENDENT (TY3231) and UPRIGHT (1Y3131) 135°F (57°C) Orange 1,2,3,4,5,6,7 Blue 1,2,3,5 155F (68°C) Red 175-F (79-C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (TY3231)* Figure 10 135°F (57°C) Orange 1, 2, 4, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (TY3231)** Figure 11 135°F (57°C) Orange 1, 2, 3, 4, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) 8.0 3/4" NPT PENDENT (TY4231) and UPRIGHT (TY4131) 135°F (57°C) Orange 1,2,3,4,5,6,7 Blue 1,2,5 155°F (68°C) Red 175-F (79-C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (1Y4231)' Figure 12 135°F (57°C) Orange 1, 2,5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (TY4231)** Figure 13 135°F (57°C) Orange 1,2, 3, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) 8.0 1/2" NPT PENDENT (TY4931) and UPRIGHT (1Y4831) 135°F (57°C) Orange 1, 2, 4, 5, 6 Blue 1, 2, 5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) NOTES: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. * Installed with Style 10(1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Ustings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS Tyco 1Y3231 QR semi-recessed pendant 12 TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL I CHROME SIGNAL LEAD FACTOR BRASS 'PLATED WHITE COATED PENDENT (TY1231) and 2.8 UPRIGHT (TYII3I) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY1231) PENDENT (TY2231) and 4.2 UPRIGHT (TY2131) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY2231) PENDENT (TY3231) 175 PSI 5.6 and UPRIGHT (TY3131) 250 PSI (17,2 BAR) (12,1 BAR) 1/2" NPT OR 175 PSI (12,1 BAR) RECESSED (SEE NOTE 1) PENDENT (TY3231) N/A PENDENT (TY4231) 175 PSI 8.0 and UPRIGHT (TV4131) (12,1 BAR) 3/4" NPT 175 PSI (12,1 BAR) RECESSED N/A PENDENT (TY4231) 8.0 PENDENT (TY4931) 175 PSI 1/2" NPT and UPRIGHT (1Y4831) 175 PSI (12,1 BAR) (12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) Only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. Care and Maintenance The TYCO Series TY-FRB must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to TABLE C MAXIMUM WORKING PRESSURE corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). . Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. Tyco TY3231 QR semi-recessed pendant 13 TFPI7I Page 9 of 10 - 2-7/8" DIA. 5/8*1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. I 1/4" (6,4 mm) / FACE OF (57,2 mm) I MOUNTING SPRINKLER PLATE FITTING 1/8" I (3,2 mm) 7,1 MOUNTING - I SURFACE CLOSURE CLOSURE SERIES 1-1/4"(31,8 mm)t TY-FRB 3/4"(19,1 mm) FIGURE 10 SERIES 7Y-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. _,.., 1/4" (6,4 mm) /1 (57,2 mm) FACE OF MOUNTING SPRINKLER L,. - PLATE FITTING )- -(i-- I (3,2 mm) MOUNTING / SURFAC5// CLOSURE SERIES 1-5/16" (333 mm) TVFRB 13/16" (20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 2-7/8" DIA. 1/2*1/8" (73,0 mm) 1/2"(12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. I 1/4" (6,4 mm) / FACE OF (57,2 mm MOUNTING FITTING [çf1 PLATE 1/8" (3,2 mm) /Aq I J-. MOUNTING SURFACE __ SERIES 1-1/4"(31,8 mm) CLOSURE TV-FRB 1" (25,4 mm) FIGURE 11 SERIES 7Y-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) - 1/2'_(12,7mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) / FACE OF - (57,2 mm) MOUNTING SPRINKLER - PLATE FITTING 1/8" (3,2 mm) 7721 P277. I MOUNTING SURFACE CLOSURE SERIES 1-5/16__(333mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 INCH NPT WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B' USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Tyco TY3231 QR semi-recessed pendant 14 TFPI7I Page 10 of 10 PIN 57- XXX- X- XXX SPRINKLER IN FINISH 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (1/2"NPT) TY2231 370 5.6K UPRIGHT (1/2"NPT) TY3131 371 — 5.6K PENDENT (1/2"NPT) TV3231 390 8.0K UPRIGHT (3/4"NPT) TV4131 391 8.0K PENDENT (3/4"NPT) TY4231 360 8.0K UPRIGHT (1/2"NPT) 1Y4831* 361 8.0K PENDENT (1/2"NPT) TY4931° TEMPERATURE RATINGS 135 135°F (57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C) 1 NATURAL BRASS - PURE WHITE (RAL9O1O)° — L A SIGNAL WHITE I j (RAL9003) JET BLACK (RAL9005)** 7LEAD COATED 9 CHROME PLATED * Eastern Hemisphere sales only. Available in only 2.8K, 4.2K, and 8.0K, 155°F (68°C) and 200°F (93°C); requires lead time to manufacture. TABLED SERIES 7Y-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright) Sprinkler (specify) tempera- ture rating, (specify) finish or coating, P/N (specify from Table D) Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*) Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Refer to Technical Data Sheet TFP770 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright '© 2013 Tyco Fire Products LP. All rights reserved. t Co Tyco Fire Protection Products 15 I Worldwide Contacts tqc www.tyco4lre.com I CENTRAL Series RF11 - 56 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General Description The TYCO Series RFll 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers featur- ing a flat cover plate designed to con- ceal the sprinkler. These sprinklers are optimal for architecturally sensitive ar- eas such as hotel lobbies, office build- ings, churches, and restaurants. Each sprinkler includes a Cover Plate! Retainer Assembly and a Sprinkler/ Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or applica- tion of the finish coating to a fixed ceiling. Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. Provides for 1!2 inch (12,7 mm) of vertical adjustment to allow a mea- sure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. The Series RFll Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling in- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. stallation or finish. The tip of the Pro- tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently push- ing the ceiling product against the Pro- tective Cap. When ceiling installation is complete, the Protective Cap is re- moved and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFll Standard Response (5-mm bulb) "Royal Flush II" Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. (Refer to Figure 5) The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. The Series RFll Concealed Pendent Sprinklers described herein must be installed and maintained in compli- ance with this document and with the applicable standards of the National Fire Protection Association, in addi- tion to the standards of any authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number f TY3531 - 3 mm bb UIIiiiuiiuiuiii 1Y3551 - 5 mm bulb Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Cri- teria section. TY3531 (3-mm Bulb) is UL Listed, C-UL Listed, VdS Approved (Certif- icate No. G4090007), and NYC Ap- proved (MEA 353-01-E) as Quick Response. TY3531 (3-mm Bulb) is FM and LPCB Approved (Ref. No. 094a/10) Approved as Standard Response. Factory Mutual and LPCB do not approve any concealed sprinklers for quick response. 1Y3551 (5-mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a19), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFll Standard Response Concealed Sprinkler (TY3551). Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F (68°C) Sprinkler with 139°F (59°C) Plate 200°F (93°C) Sprinkler with 165°F (74°C) Plate Discharge Coefficient K= 5.6 GPM/psi112 (80,6 LPM/barl'2) Adjustment 1/2 inch (12,7 mm) Finishes See the Ordering Procedure section. Tyco i'c2 oncealed pendant MARCH 2013 TFPI8I 16 1FPI8I Page 2 of 4 Physical Characteristics Frame ...................Bronze Support Cup..............Chrome Plated Steel Guide Pins .........Stainless Steel Deflector.................Bronze Compression Screw.........Brass Bulb ......................Glass Cap.............Bronze or Copper Sealing Assembly.........Beryllium Nickel w/ TEFLON Cover Plate................Brass Retainer ..................Brass Ejection Spring......Stainless Steel Design Criteria The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency; for example, UL List- ing is based on NFPA 13 and VdS Ap- proval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Tyco Fire Pro- tection Products at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFII Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. wI.)tLg Do not use the Series RFII in applica- tions where the air pressure above the ceiling is greater than that be- low. Down drafts through the Sprin- kler/Support Cup Assembly can delay sprinkler operation in a fire situation. Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector - supported by the Guide Pins - then drops down to its operational position. The glass bulb contains a fluid that ex- pands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. 1/2 NP1 FRAME SUPPOR CUP WITI ROLL FOR THREAD GUIDE PINS (2) Installation The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F (68°C) and 3/32 inch (2,4 mm) for the 200°F (93°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-Ibs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler In- let with consequent leakage or impair- ment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFIl Sprinkler Wrench. (Refer to Figure 3.) Apply the RFll Sprinkler Wrench to the Sprinkler as shown in Figure 3. Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and DEFLECTOR --- -------- - SPRINKLER/SUPPORT CUP ASSEMBLY LECTOR BOPPED POSITION) EALING SEMBLY CAP BULB PRESSION CREW THREAD INTO RETAINER SUPPORT WITH THREAD CUP UNTIL 0 0 DIMPLES MOUNTING SURFACE IS EJECTION FLUSH WITH SPRING CEILING I SOLDER ' OVER COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY Tyco TY3531 QR concealed pendant 17 3/16° to 11/16" (4,8 to 17,5 mm) REFERENCE COVER PLATE PROFILE DEPTH DIMENSION B MANUFACTURER DEFLECTOR PRESET GAP IN DROPPED 3/32" (2,4 mm) POSITION COVER PLATE DIAMETER DIMENSION A COVER PLATE RETAINER ASSEMBLY 3-1/4 inches (82,6 mm) C: 2-3/8 to 2-5/8 Inches (60,3 to 66,7 mm) 3/16 inches (4,8 mm) D: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFPI8I Page 3 of 4 FACE OF SPRINKLER FITTING SPRINKLER SUPPORT CUP ASSEMBLY 1/2' (12,7 mm) THREADED D ADJUSTMENT FACE OF CEILING, RETAINING RING MOUNTING SURFACE CLEARANCE HOLE - DIAMETER DIMENSION Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clear- ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. As long as the Protective Cap remains in place, the system is considered "Out of Service" Step 6. After the ceiling has been com- pleted with the 2-1/2 inch (63,5 mm) di- ameter clearance hole and in prepa- ration for installing the Cover Plate! Retainer Assembly, remove and dis- card the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5; otherwise, proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented ac- cording to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step 8. Screw on the Cover Plate! Retainer Assembly until the Retainer (shown in Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer As- sembly sufficiently to contact the ceil- ing, you must reposition the Sprinkler Fitting. Tyco 1Y3531 QR concealed pendant 18 TFPI8I Page 4 of 4 Care and Maintenance The TYCO Series RFII 5.6 K-fac- tor, "Royal Flush II" Concealed Pen- dent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection sys- tem from the proper authorities and notify all personnel who may be affect- ed by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap be- tween the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceil- ing requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Exercise care to avoid damage to sprinklers before, during, and after in- stallation. Replace sprinklers damaged by dropping, striking, wrench twisting, wrench slipping, or the like. Also, re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: Series RFll (specify SIN), K=5.6, "Royal Flush II" Pendent Sprin- klers (specify) temperature rating and (specify) finish, PIN (specify). 155°F (68°C) 93°C TY3531 51-792-1-155 Separately Ordered Cover Plate 1Y3551 51-790-1-155 5 -1-200 Retainer Assembly: Specify: (temperature rating from be- low) Series RFIl Concealed Cover Plate with (finish), P/N (specify). 139°F (59°C)(8) 165°F (74°C)(b) Grey White (RAL9002) .... 56-792-0-135 56-792-0-165 Brass..........56-792-1-135 56-792-1-165 Pure White (c) (RAL9010) .... 56-792-3-135 56-792-3-165 Signal White (RAL9003).... 56-792-4-135 56.792-4-165 Jet Black (RAL9005).... 56-792-6-135 59-792-6-165 Brushed Chrome ........56-792-8-135 56-792-8-165 Chrome ........56-792-9-135 56-792-9-165 Custom ........56-792-X-135 56-792-X-165 For use with 155°F (68°C) sprinklers. For use with 200°F (93°C) sprinklers. Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFll Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001. If you must remove a sprinkler, do not reinstall it or a replacement without re- installing the Cover Plate/Retainer As- sembly. If a Cover Plate/Retainer As- sembly becomes dislodged during service, replace it immediately. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in compliance with this document, as well as with the applicable stan- dards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authori- ties having jurisdiction. Contact the in- stalling contractor or sprinkler manu- facturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Tyco All rights reserved. tqco 19 9155 ARCHIBALD AVE, SUITE 906 • RANCHO CUCAMONGA, CA 91730 • 909-527-4420 • RCMFIRE.COM • LIC# 793205 C16. HANGERS AND BRACING ALL MATERIALS PROVIDED FOR THIS PROJECT WILL BE NEW, UL LISTED AND/OR FM APPROVED. IN CASES OF UNAVAILABILITY, ANY SUBSTITUTIONS WILL BE AN EQUAL OR BETTER PRODUCT. SECTION 3- HANGERS AND BRACING 20 -2 -' 2-#14x1 Fig. 58 -Threaded Side Beam Bracket Size Range - 3/8" rod, pipe sizes 1/2" thru 4" Material - Carbon Steel Function - Practical and economical bracket used to support piping from wood, concrete or steel beams. Features - Unique design allows rod to be easily threaded into bracket. Offset design permits unlimited rod adjustment. Center mounting hole will accept 3/8" and 1/2" fastener bolts. Per NFPA 13: 1/2" thru 2" pipe requires 3/8" fastener, 21/2" thru 4" pipe requires 1/2" fastener.* Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL), and Factory Mutual Engineering approved thru 4" pipe. *Note - Additionally UL has listed the Fig. 58 with fasteners as shown in table below. C®US LISTED Finish - Plain Note - Available in Electro-Galvanized finish. Order By - Figure number and finish C UL Listed Fastener Table Pipe Size Qty. Fastener Type Material 2 2 #16 x 2 Drive Screws Wood 2 1 3/8 Lag Bolt Wood 21/2 -4 1 .1/2 Lag Bolt Wood 31/2 2 1/4 x 11/2 Lag Bolt Wood 4 2 1/4 x 2 Lag Bolts* Wood 4 2 1/4 x 1 tek screws 14 gauge 4 2 1/4 x 1 tek screws 16 gauge * No pre-drilling required Dimensions • Weights Pipe Rod Max. Rec. Approx. Size Size A B C Load Lbs.* WtJ100 1/2 thru 4 3/8 23/4 11/2 11/8 300 14 * With safety factor of 5. 2- 1/4 x2 Lag Bolts (No Pre-drilling) Up to 4 lnth Pipe Per NFPA 1 - Lag Bolt - UpTo4 inch Pipe \ _, 2-#16x2 Drive Screws ll2Thru2 inch Pipe OFFICE/MANUFACTURING FACIUTY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FA)(: 951.737.0330 Tolco side beam fig58 CUSTOMER SERVICE • 800.786.5266 www.tolco.com SAMMYS® FOR WOOD -No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. abdeodemrxIsiTaUc\ www.ltwbulidex.comJ #14 Black Nut Driver Part # 8113910 'A . #14 SW Red Nut Driver Part #8114910 114 8002957 GST 100 114x? 670 (3/4 Ply) 25 125 EIIT 1M 8co39s7 GST 2oo 1M 1760 r) 25 12 114 8004957 GST 300 1/4 x 3 2060 (Fir) 25 125 3/8' 8DO7957 GST 10 I 1/4X1 _ __!j 3/8 8008957 GST 20 114 x Z 1760 (Fir) 850 1475 25 125 L 3/8'ii80685 GST 2O-SS1/4x2 1760 (Fir) 850 25 125j 3/8 8009925 GST 25-380 3/8x2-1/2_2113(Fir) 1500 25125 LL x32060 (Fir)1500147525 125] 3/8_8069925 GST 30-SS 114x3 2060 (Fir) 25 125 [ 380925 GST 40 114 2180 (Fir) - 25 1/?8013925 GST 21/4x2_1760 (Fir) 25 125 1/2" 8014925G3125-380 318 x 2-1(2"2113 (Fir)________ 25 125 1/2" 8015925 GST3 1/4x3" 2275 (Fir) 25 125 OMADEINU.SAV (ro-R). SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe Installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. 9155 ARCHIBALD AVE, SUITE 906 • RANCHO CUCAMONGA, CA 91730 • 909-527-4420 • RCMFIRE.COM • LIC# 793205 C16. END OF SUBMITTAL THIS PAGE LEFT BLANK INTENTIONALLY ALL MATERIALS PROVIDED FOR THIS PROJECT WILL BE NEW, UL LISTED AND/OR FM APPROVED.. IN CASES OF UNAVAILABILITY, ANY SUBSTITUTIONS WILL BE AN EQUAL OR BETTER PRODUCT. END OF SUBMITTAL 23