Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2282 FARADAY AVE; ; FPC2017-0125; Permit
PERMIT REPORT r( 4ity of Carlsbad Print Date: 10/20/2021 Job Address: 2282 FARADAY AVE. CARLSBAD, CA 92008-7208 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2120614600 Track #: Valuation: $232,151.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Plan Check U: Project Title: Description: IONIS -SPRINKLER TI 7-100 HEADS (37) Permit No: FPC2017-0125 Status: Closed - Finaled Applied: 05/15/2017 Issued: 07/26/2017 Finaled Close Out: 05/03/2021 Inspector: Final Inspection: FPContractor: SCHMIDT FIRE PROTECTION CO INC-DO NOT USE 4760 MURPHY CANYON RD SAN DIEGO, CA 92123 (858) 279-6122 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov lonis 2282 Material Submittal FPC20I7-0125 2282 FARADAY AVE C tqco Ffre Protection Products Worldwide Contacts I www.tyco-fire.com Series RFII - 56 K-factor "Royal Flush Il" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage S S General Description The TYCO Series RFII 5.6 K-factor, Royal Flush II" Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers fea- turing a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensi- tive areas such as hotel lobbies, office buildings, churches, and restaurants. Each sprinkler includes a Cover Plate! Retainer Assembly and a Sprinkler! Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. Provides for 1!2 inch (12,7 mm) of vertical adjustment to allow a measure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. The Series RFII Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling installation or finish. The tip of the Pro- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently pushing the ceiling product against the Pro- tective Cap. When ceiling installa- tion is complete, the Protective Cap is removed and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFII Standard Response (5-mm bulb) "Royal Flush Il" Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY3531 - 3 mm bulb TY3551 - 5 mm bulb APRIL 2016 Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Criteria section. TY3531 (3 mm Bulb) is UL Listed, C-UL Listed and NYC Approved (MEA 353-01-F) as Quick Response. TY3531 (3 mm Bulb) is VdS Approved (Certificate No. G4090007). TY3531 (3 mm Bulb) is FM and LPCB Approved (Ref. No. 094a/10) as Standard Response. Note: FM and LPCB do not approve concealed sprinklers for quick response. TY3551 (5 mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a!9), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFII Standard Response Concealed Sprinkler (TY3551) Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F (68°C) Sprinkler with 139°F (59°C) Plate 200°F (93°C) Sprinkler with 165°F (74°C) Plate Discharge Coefficient K= 5.6 GPM/psi112 (80,6 LPM/bar112) TFPI8I TFPI8I Page 2 of 4 Adjustment 1/2 inch (12,7 mm) Finishes See the Ordering Procedure section. Physical Characteristics Frame ............................Bronze Support Cup ............Chrome Plated Steel Guide Pins..................Stainless Steel Deflector ..........................Bronze Compression Screw ..................Brass Bulb ...............................Glass Cap .....................Bronze or Copper Sealing Assembly. . Beryllium Nickel w/TEFLON Cover Plate .........................Brass Retainer............................Brass Ejection Spring ..............Stainless Steel Design Criteria The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency; for example, UL Listing is based on NFPA 13 and VdS Approval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Tyco Fire Protection Products at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFII Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. L1)t(.1 Do not use the Series RFII in applica- tions where the air pressure above the ceiling is greater than that below. Down drafts through the Sprinkler/Support Cup Assembly can delay sprinkler operation in a fire situation. Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector - supported by the Guide Pins - then drops down to its operational position. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. 1/2 NPI FRAME SUPPOR CUP WlTl ROLL FORr' THREADS GUIDE PINS (2) DEFLECTOR THREAD It SUPPOF CUP UN MOUNTII SURFACE FLUSH W CEILIN( SOLDEI TABS (3) Installation The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- klerheld horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F (68°C) and 3/32 inch (2,4 mm) for the 200°F (93°C) tem- perature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 ft.-Ibs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench. (Refer to Figure 3.) Apply the RFII Sprinkler Wrench to the Sprinkler as shown in Figure 3. LECTOR ROPPED POSITION) EALING SEMBLY CAP BULB PRESSION CREW SPRINKLER/SUPPORT CUP ASSEMBLY COVER PLATE/RETAINER ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY JVER PLATE AINER THREAD APLES CTION 'RING 3-1/4 inches (82,6 mm) C: 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) 3/16 inches (4,8 mm) D: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS S 0 \/ MANUFACTURER DEFLECTOR COVER PLATE PRESET GAP IN DROPPED RETAINER 3/32" (2,4 mm) POSITION ASSEMBLY COVER PLATE DIAMETER DIMENSION A 3/16 to 11/16" (4,8 to 17.5 mm) REFERENCE COVER PLATE - PROFILE DEPTH DIMENSION B TFPI8I Page 3 of 4 CLEARANCE HOLE DIAMETER i DIMENSION C FACE OF S SPRINKLER FITTING SPRINKLER SUPPORT CUP -- ASSEMBLY 1/2 (12,7 mm) THREADED D ADJUSTMENT FACE OF CEILING, RETAINING RING MOUNTING 777 SURFACE j Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clear- ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. IA!E)tL€ As long as the Protective Cap remains in place, the system is considered "Out of Service". Step 6. After the ceiling has been completed with the 2-1/2 inch (63,5 mm) diameter clearance hole and in preparation for installing the Cover Plate/Retainer Assembly, remove and discard the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5; otherwise, proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented according to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. TFPI8I Page 4 of 4 S SUPPORT -- SPRINKLER FACE OF ORIENT CUP // CEILING .—'\ SEAL t:5t:VIzI_ AS SHOWN = z COVER PLATE RETAINER ASSEMBLY AIR AND DUST LIP OF COVER SEAL RETAINER PLATE FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TV3551) S Step 8. Screw on the Cover Plate! Retainer Assembly until the Retainer (shown in Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer Assembly suf- ficiently to contact the ceiling, you must reposition the Sprinkler Fitting. Care and Maintenance The TYCO Series RFll 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceiling requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) Exercise care to avoid damage to sprin- klers before, during, and after instal- lation. Replace sprinklers damaged by dropping, striking, wrench twist- ing, wrench slipping, or the like. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) If you must remove a sprinkler, do not reinstall it or a replacement without reinstalling the Cover Plate/Retainer Assembly. If a Cover Plate/Retainer Assembly becomes dislodged during service, replace it immediately. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or sprinkler manufac- turer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. Limited Warranty Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: Series RFII (specify SIN), K=5.6, "Royal Flush II" Pendent Sprin- klers (specify) temperature rating and (specify) finish, P/N* (specify): 1V3531 51-792-1-155 51-792-1-200 TY3551 51-790-1-155 51-790-1-200 Use Suffix "I" for ISO 7-1 connection; for example. 51 -792-1-155-I Separately Ordered Cover Plate! Retainer Assembly: Specify: (temperature rating from below) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139°F (59°c)(a) 165°F (74°00)(b) Grey White (RAL9002) .... 56-792-0-135 56-792-0-165 Brass..........56-792-1-135 56-792-1-165 Pure White (c) (RAL9010) .... 56-792-3-135 56-792-3-165 Signal White (RAL9003) .... 56-792-4-135 56-792-4-165 Jet Black (RAL9005) .... 56-792-6-135 59-792-6-165 Brushed Chrome ........56-792-8-135 56-792-8-165 Chrome ........56-792-9-135 56-792-9-165 Custom ........56-792-X-135 56-792-X-165 For use with 155°F (68°C) sprinklers. For use with 200°F (93°C) sprinklers. Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 56-000-1-075 S For warranty terms and conditions, visit www.tyco-fire.com. Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2016 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation tqco Fite Protection Products tqcn Fire Protection Products Worldwide Contacts I www.tyco-fire.com Series TY-B - 2.8, 56, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description TYCO Series TY-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers described in this technical data sheet are standard response, standard coverage decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commer- cial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants. The recessed version of the Series TY-B Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cau- tions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TV-B Pendent Sprinkler can be obtained by utilizing the Series TV-B Pendent Sprinkler in combination with the Model S2 Shield. NOTICE The Series 7Y-B Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (NFPA), in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. Contract the installing contractor or product manufacturer with any questions. Sprinkler Identification Numbers (SINs) TY1151 - Upright 2.8K, 1/2" NPT 1Y1251 - Pendent 2.8K, 1/2W' NPT TY3151 - Upright 5.6K, 1/2 NPT 1Y3251 - Pendent 5.61K, 1/2" NPT TY4151 - Upright 8.0K, 3/4" NPT TY4251 - Pendent 8.0K, 3/4 NPT 1Y4851 - Upright 8.01K, 1/2'S NPT 1Y4951 - Pendent 8.0 K, 1/2" NPT NOVEMBER 2014 % AL-1 I ..'. TFPI5I S 1/2 NPT* UPRIGHT S TFPI5I Page 2 of 8 CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw / ___ 3 - Sealing 6 - Deflector * Assembly 7 - Bushing - / I / 1 • 4 -Bulb 7/16 2-1/4 / (11,1 mm) I (57.2 mm) 7 1j NOMINAL I I MAKE-IN j * Temperature rating is I indicated on Deflector. 2-3/16 1-9/16° I (55,6 mm) (39,7 mm) - 5 ** Pipe thread connections 1 * /1 per ISO 7-1 can be 6 provided on special 1/2..NPT** I WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 1 SERIES TY-B UPRIGHT (TYI151) AND PENDENT (TY1251) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing . 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 7/16 11,1 mm) OMINAL I 2- MAKE-IN (55,6 3/16 mm) I 2-3/16° 1-1/2° (556 mm ,,,/ (38,1mm) - I WRENCH FLATS PENDENT 4 5 6* STYLE 10 -.----- 2-7/8° (73,0 mm) DIA. —i RECESSED ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE SERIES TY-B UPRIGHT (TY3 151) AND PENDENT (TY3251) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE [I S TFPI5I Page 3 of 8 * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request.. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE (127 mm) _____ NOMINAL J 2-5/16 (58,7 mm) MAKE-IN 2-1/4 1-9/16 (57,2 mm) / 3/4 NPT** 1 WRENCH STYLE 40 H— 2-7/8" (73,0 mm) DIA. —H FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT FIGURE 3 SERIES TV-B UPRIGHT (TY4 151) AND PENDENT (TY4251) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT STANDARD RESPONSE CROSS SECTION CEILING PLATE SEATING SURFACE / 2-1/4" (57,2 mm) 1-9/16" (39,7 mm) 1 - Frame 5 - Compression 2 - Button Screw 1 3 - Sealing 6 - Deflector* Assembly f\3 4-Bulb 2 LI [X * Temperature rating is 4 indicated on Deflector. 5 ** Pipe thread connections per ISO 7-1 can be 6* provided on special request. J7 1\ 7/16" I (11.1 mm) I NOMINAL I MAKE-IN I I1 1/ I 2-3/16" (55,6 mm) / 1/2" NPT** I WRENCH FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 4 SERIES TV-B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE 0 S L TFPI5I Page 4 of 8 K SPRINKLER TYPE TEMPERATURE RATING LIQUID COLOR BULB SPRINKLER FINISH (8) NATURAL BRASS I CHROME PLATED I ** POLYESTER* LEAD COATED I WAX COATED WAX-OVER-LEAD COATED 135°F (57°C) Orange 155°F(68°C) Red UPRIGHT 2.8 NPT (TY1151) and PENDENT (TY1251) 1, 2, 3 N/A 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Figure 1 Blue 360°F (182°C) Mauve 1,2 135°F (57°C) Orange 155°F (68°C) Red UPRIGHT (TY3151) and PENDENT (TY3251) 1, 2,3,4,5,6,7 1,27 3,5 1,2,3,5 1,2,3,5 175°F(79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 1", 2—,3—, 5— 1-,2",3",5- 5.6 Figure 2 360°F (182°C) Mauve N/A 1/2" NPT 135°F (57°C) Orange 155°F (68°C) Red RECESSED PENDENT (TY3251)* 1,2,3.4,5 S N/A 175°F (79°C) Yellow 200°F (93°C) Green Figure 5 286°F (141°C) Blue 1,2 135°F (57°C) Orange 155°F (68°C) Red UPRIGHT (TY4151) and PENDENT (TY4251) 1, 2,3,4,5,6,7 1,2,5 1,2,3,5 1,2,5 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 1", 2", 3°°, 5" 2°, 5* 8.0 Figure 3 360°F (182°C) Mauve N/A 3/4" NPT 135°F (57°C) Orange 155°F (68°C) Red RECESSED PENDENT (TY4251)* 1,2,3,4,5 N/A 175°F (79°C) Yellow 200°F (93°C) Green Figure 6 286°F (141°C) Blue 1,2 135°F (57°C) Orange 155°F(68°C) Red UPRIGHT 8.0 NPT (TY4851) and PENDENT (TY4951) 1,2,3,4,5,6 N/A 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Figure 4 360°F(182°C) Mauve Notes: Listed by Underwriters Laboratories, Inc. (UL) Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) Approved by FM Global (FM Approvals) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03) Approved by the City of New York under MEA 354-01-E VdS Approved (For details contact Tyco Fire Suppression & Building Products, Enschede. Netherlands, Tel. 31-53-428-4444 / Fax 31-53-428-3377) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05) Where Polyester Coated. Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion- Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion-Resistant Sprinklers. - Installed with Style 10 )1/2 NPT) or Style 40 (3/4 NPT) 3/4W Total Adjustment Recessed Escutcheon, as applicable 150°F (66°C) maximum ceiling temperature Frame and deflector only N/A - Not Applicable TABLE A SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS 1~ TFPI5I Page 5 of 8 SPRINKLER FINISH K TYPE NATURAL CHROME POLYESTER* LEAD WAX WAX-OVER-LEAD BRASS PLATED COATED COATED COATED 2.8 UPRIGHT (TY1151) 1/2'S and 175 psi (12.1 bar) N/A NPT PENDENT(TY1251) UPRIGHT (TY3151) and 5.6 PENDENT (TV3251) 250 psi (17,2 bar) (a) 1/2" OR - . NPT 175 psi (12,1 bar) RECESSED PENDENT (TY3251) UPRIGHT (TV4151) and 175 psi (12,1 bar) 8.0 PENDENT (TY4251) 3/4- NPT RECE ,D251) PE1DENT 175 psi (12,1 bar) N/A 8.0 UPRIGHT (TY4851) 1/2" and 175 psi (12,1 bar) NPT PENDENT (TY4951) Notes: a. The maximum working pressure o)250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL), the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL). and the Approval by the City of New York. Frame and deflector only N/A - Not Applicable TABLE B SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS MAXIMUM WORKING PRESSURE S Technical Data Approvals UL and C-UL Listed FM Approved LPCB Approved VdS Approved NYC Approved (Refer to Table A for complete ap- proval information, including corro- sion-resis-tant status.) Maximum Working Pressure Refer to Table B. Discharge Coefficient K=2.8 gpm/psi112 (40,3 pm/bar112) K=5.6 gpm/psi112 (80,6 pm/bar112) K=8.0 gpm/psi1/2 (115,2 1pm/bar112) Temperature Ratings Refer to Table A. Finishes Sprinkler: Refer to Table C. Recessed Escutcheon: Signal or Pure White, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame ........................Bronze Button..................Brass/Copper Sealing Assembly.......Beryllium Nickel w/TEFLON Bulb .........................Glass Compression Screw............Bronze Deflector.....................Copper Bushing (K=2.8) ...............Bronze Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria TYCO Series TY-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of the FM Global Loss Prevention Data Sheets). Only the Style 10 or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. FIGURE 5 SERIES TV-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. - (73,0 mm) 3/4" (19,1 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) MOUNTING DIAT 1/8" (3,2 mm) 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING TFPI5I Page 6 of 8 S 2-7/8 DIA. -. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4' (6,4 mm) FACE OF (57.2mm) MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) MONTIN7_4 - SURFACE SERIES 1-1/4" (31,8 mm)t CLOSURE TY-B 3/4" (19,1 mm) WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 7' W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 8 W-TYPE 7 RECESSED SPRINKLER WRENCH Installation MOUNTING SURFACE CLOSURE SERIES TV-B 1-5/16" (33,3 mm) 13/16" (20,6 mm) TYCO Series TV-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers must be installed in accordance with this section. FIGURE 6 SERIES TV-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 360°F (182°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Obtain a leak-tight 3/4 inch NPT sprinkler joint by applying a minimum to maximum torque of 10 to 20 ft.-lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuf- ficient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. TFPI5I Page 7 of 8 C Upright and Pendent Sprinklers The Series TV-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions: Note: Install pendent sprinklers in the pendent position; install upright sprin- klers in the upright position. Step 1. With pipe thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 7). For wax-coated sprinklers, use an 8 or 10 inch adjustable wrench. With reference to Figures 1 through 4, the W-Type 7 Recessed Sprinkler Wrench or an adjustable wrench, as applicable, is to be applied to the sprinkler wrench flats. When installing wax-coated sprinklers with an adjustable wrench, exercise care to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environment. Open the jaws of the wrench sufficiently wide to pass over the wrench flats without damaging the wax coating. Before wrench tightening the sprinkler, adjust the jaws of the wrench to contact only the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, inspect the sprinkler wrench flats and frame arms and retouch (repair) the wax coating when- ever the coating has been damaged and bare metal is exposed. Retouch the wax coating on the wrench flats by gently applying a heated 1/8 inch diameter steel rod to the damaged areas of wax, to smooth it back over areas where bare metal is exposed. NOTICE Only retouching of the wax coating applied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precau- tions need to be taken when handling the heated rod in order to prevent the installer from being burned. Recessed Pendent Sprinklers The Series TV-B Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions: Step A. After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 8). With reference to Figure 3 or 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling is installed or the finish coat is applied, slide on the Style 10 or 40 Closure over the Series TV-B Sprinkler and push the Closure over the Mounting Plate until its flange contacts the ceiling. Care and Maintenance TYCO Series TV-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. The owner must assure that the sprinklers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dust- ing with a feather duster; otherwise, non-operation in the event of a fire or inadvertent operation may result. Absence of an escutcheon, which is used to cover a clearance, may delay the time to sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist' slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to Installation Section.) The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinklers are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. S S TFPI5I Page 8 of 8 P/N 57 - XXX - X - XXX SPRINKLER TEMPERATURE SIN FINISH RATING 1 NATURAL BRASS 135 135°F (57°C) PURE WHITE (RAL9010) * 155 155°F (68°C) POLYESTER 570 5.6K UPRIGHT (1/2" NPT) TY3151 SIGNAL WHITE (RAL9003) 175 175°F (79°C) POLYESTER 571 5.6K PENDENT (1/2" NPT) TY3251 JET BLACK (RAL9005) °° 200 200°F (93°C) POLYESTER 590 8.0K UPRIGHT (3/4 NPT) TY4151 6 WAX COATED 286 286°F (141°C) 286°F (141°C) MAX 591 8.0K PENDENT (3/4" NPT) TY4251 7 LEAD COATED 360 360°F (182°C) 8 WAX-OVER-LEAD 000 OPEN- 286-F (141°C) MAX 561 8.0K PENDENT (1/2 NPT) TY4951 9 CHROME PLATED Notes: Eastern Hemisphere sales only Available in only 8.0K, 155°F (68°C) or 200°F (93°C): requires lead time to manufacture Available only for 80 K-factor 1Y4151 and TY4251 for use in deluge systems ("OPEN" indicates sprinkler assembly without glass bulb, button, and sealing assembly) TABLE C SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 530 2.8K UPRIGHT (1/2" NPT) TY115 1 531 2.8K PENDENT (1/2" NPT) TY1251 560 8.0K UPRIGHT (1/2" NPT) TY4851 fl Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TV-B (specify SIN), (specify K-factor), (specify Upright or Pendent) Sprinkler with (specify) temperature rating, (specify) finish or coating, P/N (Refer to Table C) Recessed Escutcheon Specify: Style (10 or 40) Recessed Escutcheon with (specify) finish, P/N* Refer to Technical Data Sheet TFP770 Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Wax Sticks (for retouching wrench-damaged wax coating) Specify: (specify color, below) Colored Coded Wax Stick for retouching (specify temperature rating) temperature-rated Series TV-B Sprinklers, P/N (specify) Black for 135°F (57°C) ......P/N 56-065-1-135 Red for 155°F (68°C) .......P/N 56-065-1-155 Yellow for 175°F (79°C) .....P/N 56-065-1-175 Blue for 200°F (93°C) and 286°F (141°C) .........P/N 56-065-1-286 Note: Each wax stick is suitable for retouching up to 25 sprinklers. Note: The wax used for 286°F (141°C) sprinklers is the same as for 200°F (93°C) sprinklers, and, therefore, the2860F(1410C) sprinkler is limited to the same maximum ceiling temperature as the 200°F (93°C) sprinkler (i.e., 150°F [660C]). GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of the DuPont Corporation. Fire Protection Products Upright and Pendent Horizontal Sidewall Recessed Pendent Conventional Vertical Sidewall Recessed Horizontal Sidewall S tqco Fire Protection Products Worldwide Contacts www.tyco-fire.com I Series TY-B and TY-FRB Sprinklers Alternate Materials of Construction Stainless Steel, SMO, and Titanium General Description The TYCO Series TY-B and TY-FRB Sprinklers described in this technical data sheet are corrosion resistant sprin- klers designed for use in commercial occupancies where corrosive atmo- spheres may exist. The TY-B with its 5 mm diameter heat sensitive glass bulb is rated standard response, whereas the TY-FRB with its 3 mm diameter heat sen- sitive glass bulb is rated quick response. The alternate materials of construction for the TY-B and TY-FRB Sprinklers, that is Stainless Steel, SMO, or Titanium, are utilized to extend the life of a sprinkler beyond that which might be expected of copper alloy sprinklers exposed to corrosive atmospheres. Although cor- rosion resistant sprinklers have passed the standard corrosion tests of the ap- plicable approval agencies, the test- ing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these alternate materials of construc- tion for any given corrosive environment. The effects of ambient temperature, con- centration of chemicals, and gas/chemi- cal velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 16 OCTOBER 2014 TFP68O TFP68O Page 2 of 16 Pendent and Upright Sprinklers Sprinkler Technical The pendent and upright sprinklers are S standard coverage spray sprinklers avail- Identification Data able in either 5.6 or 8.0 K-factor. The recessed version is intended for use in Number (SIN) Approvals areas with a finished ceiling. The two- Refer to Tables A, B, C, and D piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheons TY-B Stainless Steel Maximum Working Pressure provide 1/2 inch (12,7 mm) of recessed Standard Response 175 psi (12,1 bar) adjustment or 3/4 inch (19,1 mm) of to- 1Y8191 - Upright 5.6K, 1/2 NPT tal adjustment from the flush pendent 1Y8291 - Pendent 5.6K, 1/2 NPT Temperature Rating position. The adjustment provided by 1V9191 - Upright 8.0K, 3/4' NPT Refer to Tables A, B, C, and D the Recessed Escutcheon reduces the 1Y9291 - Pendent 8.0K, 3/4' NPT Physical Characteristics accuracy to which the fixed pipe drops 1Y8691 C/UP 5.6K, 1/2' NPT Stainless Steel to the sprinklers must be cut. TY9691 - C/UP 8.0K, 3/4" NPT TY8391 - HSW 5.6K, 1/2' NPT The frame is free machining ANC4A Conventional Sprinklers 1Y8491 - VSW 5.6K, 1/2" NPT Stainless Steel, per BS 3146 PT 2. The The 5.6 or 8.0 K-factor conventional Deflector is Type 316L (UNS 31603) sprinklers are intended to be installed TY-FRB Stainless Steel Stainless Steel per ASTM A479/479M either pendent or upright and, in either Quick Response or BS EN 10088 WN1.4401/4404. The position, they produce a spherical water TY8181 - Upright 5.6K, 1/2" NPT Compression Screw and Button are discharge pattern with approximately 1V8281 - Pendent 5.6K, 1/2" NPT Type 316L (UNS 31603) Stainless Steel 50% of the discharge upwards and ap- TY9181 Upright 8.0K, 3/4" NPT per ASTM A479/479M or BS EN 10088 proximately 50% of the discharge di- TY9281 - Pendent 8.0K, 3/4" NPT WN1.4404. The Sealing Assembly con- rected downwards. TY8681 - C/UP 5.6K, 1/2 NPT sists of a Disc Spring that is sealed on TV9681 - C/UP 8.0K, 3/4' NPT both its inside and outside faces with a Conventional sprinklers are generally TY8381 - HSW 5.6K, 1/2' NPT TEFLON Gasket. The Disc Spring is 1/2 used with Ordinary and Extra High haz- TY8481 - VSW 5.6K, 1/2' NPT Hard Beryllium Nickel (UNS N03360) ard Class Systems as defined by the TY-B SMO Gold Plated per MIL G-45204, Type automatic sprinkler system installation Standard Response 3, Class 2. The bulb is glass. rules of the country and authority hay- ing jurisdiction. The NFPA permits the 1Y8192 - Upright 5.6K, 1/2" NPT SMO use of conventional sprinklers (old style 1Y8292 - Pendent 5.6K, 1/2' NPT The Frame, Deflector, Compression sprinklers) where special construction 1Y8692 - C/UP 5.6K, 1/2" NPT Screw, and Button are 254 SMO features require a unique water distri- 1Y8392 - HSW 5.6K, 1/2" NPT Duplex Stainless Steel per UNS S bution; for fur vaults; or, replacement of 1Y8492 - VSW 5.6K, 1/2" NPT S31254. The Sealing Assembly con- similar sprinklers that had been installed TY-FRB SMO sists of a Disc Spring that is sealed prior to 1955. Quick Response on both its inside and outside faces 1Y8182 - Upright 5.6K, 1/2" NPT with a TEFLON Gasket. The Disc Sidewall Sprinklers 1Y8282 - Pendent 5.6K, 1/2" NPT Spring is 1/2 Hard Beryllium Nickel The horizontal and vertical sidewall sprin- TY8682 - C/UP 5.61K, 1/2" NPT (UNS N03360) Gold Plated per MIL klers are designed for installation along 1Y8382 - HSW 5.6K, 1/2" NPT G-45204, Type 3, Class 2. The bulb a wall or side of a beam and just beneath 1Y8482 - VSW 5.6K, 1/2" NPT is glass. a smooth ceiling. Sidewall sprinklers are commonly used instead of pendent and TY-B Titanium Titanium The Frame is Titanium, Grade 2 per upright sprinklers due to aesthetics or building construction considerations, Standard Response TY8193 - Upright 5.6K, 1/2" NPT UNS R50400. The Deflector is Tita- where piping across the ceiling is not TY8293 - Pendent 5.6K, 1/2' NPT nium, Grade 2 per ASTM B265-03. The Compression Screw is Titani- desirable. TY8693 - C/UP 5.6K, 1/2" NPT TY8393 - HSW 5.6K, 1/2" NPT um, Grade 5 per ASTM B348-03. A recessed version of the horizontal TY8493 -VSW 5.6K, 1/2" NPT The Button is Titanium, Grade 2 per sidewall sprinkler can be achieved by ASTM B348. The Sealing Assem- using the Style 10 Recessed Escutcheon. TY-FRB Titanium bly consists of a Disc Spring that is Quick Response sealed on both its inside and out- 1Y8183 - Upright 5.6K, 1/2" NPT side faces with a TEFLON Gasket. TY8283 - Pendent 5.6K, 1/2" NPT The Disc Spring is Titanium 6AL/4V The Series TV-B and TY-FRB Sprinklers 1Y8683 -C/UP 5.6K, 1/2" NPT Ti per AMS4911J. The bulb is glass. described herein must be installed and 1Y8383 - HSW 5.6K, 1/2" NPT maintained in compliance with this docu- 1Y8483 - vsw 5.6K, 1/2" NPT ment and with the applicable standards of the National Fire Protection Associa- tion, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. Contact the S installing contractor or product manu- facturer with any questions. n S TFP68O Page 3 of 16 MODEL BULB SPRINKLER MATERIAL K- FACTOR RESPONSE TEMPERATURE TYPE LIQUID RATING STAINLESS COLOR SMO I TITANIUM STEEL 135°F (57°C) Orange 155°F (68°C) Red Pendent and 175°F (79°C) Yellow 12,3,4 3,4 Upright 200°F (93°C) Green TY-B 286°F (141°C) Blue 5.6 1/2" NPT 360°F (182°C) Mauve ______________ 135°F (57°C) Orange SR 155°F(68°C) Red Recessed Pendent* i 175°F (79°C) Yellow 1.2 NAS Figure 13 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange 155°F(68°C) I Red Pendent and 175°F (79°C) Yellow 1,2,3,4 Upright 200°F (93°C) Green TY-B 286°F (141°C) Blue 8.0 3/4" NPT 360°F (182°C) Mauve N/A ______________ 135°F (57°C) Orange SR 155°F(68°C) Red Recessed Pendent** 175°F (79°C) Yellow 1,2 Figure 14 200°F (93°C) Green 286°F (141°C) Blue NOTES: LJL Listed C-UL Listed LPCB Approved (LPCB Ref. No. 007q/0 & 007q/02) LPCB EC Certificate of Conformity - 0832-CPD-2020 Lloyd's Register Certificate of Fire Approval - SAS F060123 Lloyd's Register EC Type Examination (Module B) Certificate - MED0650147 Lloyd's Register EC (Module D) Certificate of Conformity - MED 0750238 Installed with Style 10 (1/2" NPT) Recessed Escutcheon Installed with Style 40 (3/4" NPT) Recessed Escutcheon NAS: No Approval Status N/A: Not Available TABLE A SERIES TV-B STANDARD RESPONSE 5.6 & 8.0 K-FACTOR PENDENT AND UPRIGHT SPRINKLERS LABORATORY LISTINGS AND APPROVALS 0 TFP6BO Page 4 of 16 MODEL TEMPERATURE BULB SPRINKLER MATERIAL STAINLESS SMO TITANIUM K-FACTOR RESPONSE TYPE RATING LIQUID COLOR STEEL 135°F (57°C) Orange 155°F (68°C) Red Pendent and Upright 1, 2, 3, 4 3,4 175°F (79°C) Yellow 200°F (93°C) Green TV- FR B 286°F (141°C) Blue 5.6 1/2" NPT 135°F (57°C) Orange OR 155-F (68-C) Red Recessed 175°F (79°C) Yellow Pendent* 1,2 NAS Figure 13 200°F (93°C) Green 286°F (141°C) Blue 135°F(57°C) Orange 155°F (68°C) Red Pendent and Upright 1, 2, 3, 4 175°F (79°C) Yellow 200°F (93°C) Green TY- FR B 8.0 286°F (141°C) Blue 3/4" NPT N/A 135°F (57°C) Orange OR 155°F (68°C) Red Recessed 175°F (79°C) Yellow Pendent** 1,2 Figure 14 200°F (93°C) Green 286°F (141°C) Blue NOTES: UL Listed C-UL Listed LPCB Approved (LPCB Ref. No. 007q/01 & 007q/02) LPCB EC Certificate of Conformity - 0832-CPD-2020 Lloyd's Register Certificate of Fire Approval - SAS F060123 Lloyd's Register EC Type Examination (Module B) Certificate - MED0650147 Lloyd's Register EC (Module D) Certificate of Conformity - MED 0750238 * Installed with Style 10 (1/2" NPT) Recessed Escutcheon Installed with Style 40(3/4" NPT) Recessed Escutcheon NAS: No Approval Status N/A: Not Available TABLE B SERIES TY-FRB QUICK RESPONSE 5.6 & 8.0 K-FACTOR PENDENT AND UPRIGHT SPRINKLERS LABORATORY LISTINGS AND APPROVALS 0 TFP68O Page 5 of 16 MODEL BULB SPRINKLER MATERIAL TEMPERATURE . K-FACTOR RESPONSE TYPE LIQUID STAINLESS RATING SMO I TITANIUM COLOR STEEL I 135°F (57°C) Orange 155-F (68-C) Red Horizontal 175°F (79°C) Yellow Sidewall 3,4 200°F (93°C) Green 286°F (141°C) Blue 360°F (182°C) Mauve 135°F (57°C) Orange TV-B Recessed 4 155°F(68°C) Red 5.6 1/2" NPT Horizontal Sidewall* 175°F (79°C) Yellow NAS SR Figure 15 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange 155°F(68°C) Red Vertical 175°F (79°C) Yellow Sidewall 3,4 200°F (93°C) Green 286-F (141-C) Blue 360°F (182°C) Mauve 135°F (57°C) Orange 155°F (68°C) Red Horizontal Sidewall 175°F (79°C) : Yellow 3,4 . 200°F(93°C) j Green 286°F (141°C) I Blue 135°F (57°C) 1 Orange TY-FRB Recessed 155°F (68°C) Red 5.6 1/2" NPT Horizontal Sidewall* 175°F (79°C) Yellow NAS ____________ ...... .... OR Figure 15 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange 155°F (68°C) Red Vertical Sidewall 175°F (79°C) Yellow 3,4 200°F(93°C) Green 286°F (141°C) Blue NOTES: UL Listed C-UL Listed LPCB Approved (LPCB Ref. No. 007q/01 & 007q/02) LPCB EC Certificate of Conformity - 0832-CPD-2020 Lloyd's Register Certificate of Fire Approval - SAS F060123 Lloyd's Register EC Type Examination (Module B) Certificate - MED0650147 Lloyd's Register EC (Module D) Certificate of Conformity - MED 0750238 Installed with Style 10 (1/2" NPT) Recessed Escutcheon NAS: No Approval Status N/A: Not Available TABLE C SERIES TV-B STANDARD RESPONSE AND SERfES TY-FRB QUICK RESPONSE 5.6 K-FACTOR HORIZONTAL SIDEWALL AND VERTICAL SIDEWALL SPRINKLERS LABORATORY LISTINGS AND APPROVALS S S TFP68O Page 6 of 16 MODEL BULB TEMPERATURE SPRINKLER MATERIAL STAINLESS SMO TITANIUM K-FACTOR RESPONSE TYPE LIQUID RATING COLOR STEEL 135°F (57°C) Orange 155-F (68-C) Red TV-B 5.6 Conventional 175°F (79°C) Yellow 1/2" NPT Upright 200°F (93°C) Green SR 286°F (141°C) Blue 360°F (182°C) IMauve 3,4 135°F (57°C) Orange TV-FRB 155-F (68-C) 7 Red 5.6 Conventional 175°F(79°C) is Yellow 1/2" NPT Upright OR 200°F (93°C) Green 286°F (141°C) Blue 135-F (57-C) Orange 155°F (68°C) Red TV-B 8.0 - Conventional 175°F (79°C) Yellow 3/4" NPT Upright 200°F (93°C) Green SR 286°F (141°C) Blue 360°F (182°C) Mauve 3,4 N/A 135°F (57°C) Orange TY-FRB 155-F (68-C) Red 8.0 3/4" NPT Conventional Upright 175°F (79°C) Yellow OR 200°F (93°C) Green 286°F (141°C) Blue NOTES: UL Listed C-UL Listed LPCB Approved (LPCB Ref. No. 007q/0 & 007q/02) LPCB EC Certificate of Conformity - 0632-CPD-2020 Lloyd's Register Certificate of Fire Approval - SAS F060123 Lloyd's Register EC Type Examination (Module B) Certificate - ME00650147 Lloyd's Register EC (Module D) Certificate of Conformity - MED 0750238 * Installed with Style 10 (1/2" NPT) Recesses Escutcheon NAS: No Approval Status N/A: Not Available TABLE D SERIES TY-B STANDARD RESPONSE AND SERIES TY-FRB QUICK RESPONSE 5.6 & 8.0 K-FACTOR CONVENTIONAL UPRIGHT (C/UP) SPRINKLERS LABORATORY LISTINGS AND APPROVALS 0 STYLE 10 WRENCH RECESSED FLATS ESCUTCHEON 2-1/4" (57,2 mm) 7/16' (11,1 mm) NOMINAL MAKE-IN -1/4' 2 mm) /RENCH FLATS STYLE 10 WRENCH RECESSED FLATS ESCUTCHEON S TFP68O Page 7 of 16 Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame * 4 - Bulb indicated on deflector can be provided on special request. 2 - Button .5 Compression or adjacent to orifice 7/16" 3 - Sealing Screw seat on frame. (11,1 mm) ESCUTCHEON Assembly 6 - Deflector * NOMINAL 1/2"** PLATE SEATING MAKE-IN NPT SURFACE 6 5 4 2 3 1 1/2 NPT** )— Zf/ (I,u mm) UI. -j CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 STANDARD RESPONSE SERIES TV-B STAINLESS STEEL UPRIGHT (TY8191) AND PENDENT (TY8291) SPRINKLERS SMO UPRIGHT (TVB 192) AND PENDENT (TY8292) SPRINKLERS TITANIUM UPRIGHT (TY8 193) AND PENDENT (TY8293) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame * 4 - Bulb indicated on deflector can be provided on special request. 2 - Button 5 - Compression or adjacent to orifice 7/16" 3 - Sealing Screw seat on frame. (11,1 mm) ESCUTCHEON Assembly 6 - Deflector * NOMINAL 1/2 ** PLATE SEATING MAKE-IN NPT SURFACE 6 5 4 2 3 1/2' NPT** &(IO (i,U mm uI/. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 2 QUICK RESPONSE SERIES TV-FRB STAINLESS STEEL UPRIGHT (TY8181) AND PENDENT (TY8281) SPRINKLERS SMO UPRIGHT (TV8 182) AND PENDENT (TV8282) SPRINKLERS TITANIUM UPRIGHT (TY8 183) AND PENDENT (TY8283) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT 7/16 (11,1 mm) NOMINAL MAKE-IN -1/4 2 mm) /RENCH FLATS im) Components: 1 - Frame * 4-Bulb 2 - Button 5 - Compression 3 - Sealing Screw Assembly 6 - Deflector * 6 5 4 2 3 * Temperature rating is ** Pipe thread connections per ISO 7-1 indicated on deflector can be provided on special request. or adjacent to orifice Ile seat on frame (12,7 mm) ESCUTCHEON NOMINAL 3/4 ** PLATE SEATING MAKE-IN NPT SURFACE 1/2 (12,7 mm) I ( I I -) / 2-5/16 NOMINAL Il I I I II j) (58,7 mm) MAKE-IN Ill I IP 1111 1-9/16 2mm) WRENCH ) (39,7mm) FLATS STYLE 40 WRENCH RECESSED FLATS ESCUTCHEON S Components: 1 - Frame * 4 - Bulb 2 - Button 5 - Compression 3 - Sealing Screw Assembly 6 - Deflector * 5 4 2 3 'I 2-7/8 (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 4 QUICK RESPONSE SERIES TV-FRB STAINLESS STEEL UPRIGHT (TY9 181) AND PENDENT (TV9281) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT * Temperature rating is ** Pipe thread connections per ISO 7-1 indicated on deflector 1/2" can be provided on special request. or adjacent to orifice seat on frame. (12,7 mm) ESCUTCHEON STYLE 40 NOMINAL 3/4 ** PLATE SEATING WRENCH RECESSED MAKE-IN NPT SURFACE FLATS ESCUTCHEON 1/2" NOMINAL (58,7 mm) MAKE-IN (12,7 mm) 2-5/16 1-9/16 ,2 mm) (39,7 mm) WRENCH I FLATS 1 3/4 NPT** TFP68O Page 8 of 16 I 3I4 NPT 1-.-- 2-7/8 (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT . RECESSED PENDENT FIGURE 3 STANDARD RESPONSE SERIES TV-B STAINLESS STEEL UPRIGHT (TY9191) AND PENDENT (TY9291) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT ESCUTCHEON PLATE SEATING SURFACE — \-- 2-1/4 (57.2 mm) 1-1/2 (38,1 mm) S WRENC FLATS SHOWN CROSS SECTION PENDENT SHOWN UPRIGHT TFP68O Page 9 of 16 7/16(11,1 mm) NOMINAL 1/2 ** MAKE-IN NPT ** Pipe thread connections per ISO 7-1 can be provided on special request. 6* Components: 1 - Frame * 5 2 - Button 3 - Sealing 4 Assembly 4 - Bulb 2 - Compression Screw 6 - Deflector * *Temperature 1 * rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 5 STANDARD RESPONSE SERIES Tv-B STAINLESS STEEL CONVENTIONAL (TY8691) SPRINKLERS SMO CONVENTIONAL (TY8692) SPRINKLERS TITANIUM CONVENTIONAL (TV8693) SPRINKLERS 5.6K-FACTOR, 1/2 INCH NPT 7/16(11.1 mm) NOMINAL 1/2 ** MAKE-IN NPT SHOWN PENDENT ** Pipe thread connections per ISO 7-1 can be provided on special request. 6* Components: 1 - Frame * 5 2 - Button 3 - Sealing 4 Assembly 4 - Bulb 2 - Compression Screw 6 - Deflector * * *Temperature 1 rating is indicated CROSS SECTION on deflector or SHOWN UPRIGHT adjacent to orifice seat on frame. ESCUTCHEON PLATE SEATING SURFACE S 2-1/4' (57,2 mm) (38,1 mm) WRENC FLATS FIGURE 6 QUICK RESPONSE SERIES TY-FRB STAINLESS STEEL CONVENTIONAL (TY8661) SPRINKLERS SMO CONVENTIONAL (TY8682) SPRINKLERS TITANIUM CONVENTIONAL (TY8683) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT 0 1/2 (12,7 mm) NOMINAL MAKE-IN ** Pipe thread connections per ISO 7-1 can be provided on special request. 3/4** NPT TFP68O Page 10 of 16 ESCUTCHEON 1/2 (12,7 mm) PLATE SEATING 3/4"** NOMINAL SURFACE NPT MAKE-IN ** Pipe thread connections per ISO 7-1 can be provided on special request. OR 6* 5 2-1/4" \ 1 (57,2 mm) - ------ 4 I 1-1/2 / 2 (38,1 mm) ) WRENCH I FLATS /, 3 1* SHOWN CROSS SECTION PENDENT SHOWN UPRIGHT Components: 1 - Frame * 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector * * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 7 STANDARD RESPONSE SERIES TV-B STAINLESS STEEL CONVENTIONAL (TY9691) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT S WRENCH FLATS ESCUTCHEON PLATE SEATING SURFACE 2-1/4 (57,2 mm) 1-1/2 (38,1 mm) Components: 1 - Frame * 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector * * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. SHOWN CROSS SECTION PENDENT SHOWN UPRIGHT FIGURE 8 QUICK RESPONSE SERIES TY-FRB STAINLESS STEEL CONVENTIONAL (TY9681) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT 0 TFP68O Page 11 of 16 S Components: 1 - Frame * 2 - Button 3 ; Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector * 7 - Ejection Spring Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to ac- tivate and water to flow. Design Criteria 9/16 WRENCH 1/2 ** (14,3 mm) 7 FLATS NPT DEFLECTC HAT The TYCO Series TY-B and TY-FRB Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Ap- proval agency (e.g., UL Listing is based on the requirements of NFPA 13). Only the Style 10 or 40 Recessed Escutch- eon, as applicable, is to be used for recessed installation. The Series TY-B and TY-FRB Pendent, Conventional, and Vertical Sidewall Sprinklers are only for non-recessed applications. S / 1-13/16" - -13/16 / 7/16' - (46,0 mm) / (11.1 mm) CENTERLINE NOMINAL OF SPRINKLER MAKE-IN WATERWAY 1-1/2' * Temperature 38,1 mm) rating is indicated on deflector or 2-1/4 adjacent to orifice (57,2 mm) seat on frame. ESCUTCHEON STYLE 10 - PLATE SEATING ** Pipe thread RECESSED I SURFACE connections per ESCUTCHEON ISO 7-1 can be provided on special request. mm) FIGURE 9 STANDARD RESPONSE SERIES TY-B STAINLESS STEEL HORIZONTAL SIDEWALL (TY8391) SPRINKLERS SMO HORIZONTIAL SIDEWALL (TY8392) SPRINKLERS TITANIUM HORIZONTAL SIDEWALL (TY8393) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT 9 DEFLECTO HAT 9/16 WRENCH 1/2 ** (14,3 mm) FLATS NPT TFP68O Page 12 of 16 Components: 1 - Frame * 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector * 7 - Ejection Spring CENTERLINE OF SPRINKLER WATERWAY * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. Installation The TYCO Series TY-B and TY-FRB sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 360°F (182°C) tem- perature ratings. A 1/2 inch NPT sprinkler joint should be obtained with a minimum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). A3/4 inch NPT sprinkler joint should be obtained with a minimum to maximum torque of 10 to 20 ft.-lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler by under- or over-tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series TV-B and TV-FRB Pendent and Upright Sprinklers The Series TY-B and TY-FRB Pen- dent and Upright Sprinklers must be installed in accordance with the follow- ing instructions: Step 1A. Pendent sprinklers must be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2A. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3A. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. to Figure 16). With reference to Figures 1, 2, 3, and 4, the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats. Series TV-B and TY-FRB Recessed Sprinklers The Series TY-B and TY-FRB Recessed Sprinklers must be installed in accor- dance with the following instructions: Step lB. After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 2B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 17). With reference to Figures 1, 2, 3, and 4 the W-Type 7 Recessed Sprinkler Wrench is to be applied to the wrench flats. Step 313. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10 or 40 Closure over the sprinkler and push the Closure over the Mounting Plate until it comes in contact with the ceiling. Series TV-B and TV-FRB Conventional Sprinklers The Series TY-B and TY-FRB Conven- tional Sprinklers must be installed in ac- cordance with the following instructions: Step 1C. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 2C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 16). With reference to Figures 5, 6, 7, and 8 the W-Type 6 Sprinkler Wrench is to be ap- plied to the wrench flats. Series TV-B and TY-FRB Horizontal and Vertical Sidewall Sprinklers The Series TY-B and TY-FRB Horizontal and Vertical Sidewall Sprinklers must be installed in accordance with the follow- ing instructions: Step 1D. Horizontal sidewall sprinklers are to be positioned in the horizontal po- sition with their centerline of waterway perpendicular to the back wall and paral- 7/16 (11,1mm) NOMINAL MAKE-IN 1-1/2" (38,1 mm) 2-1/4 (57,2 mm) ESCUTCHEON STYLE 10 - PLATE SEATING ** Pipe thread RECESSED I SURFACE connections per ESCUTCHEON ISO 7-1 can be provided on special request. FIGURE 10 QUICK RESPONSE SERIES TY-FRB STAINLESS STEEL HORIZONTAL SIDEWALL (TY8381) SPRINKLERS SMO HORIZONTIAL SIDEWALL (TY8382) SPRINKLERS TITANIUM HORIZONTAL SIDEWALL (TY8383) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2 (57, TFP68O Page 13 of 16 Components: 1 - Frame * 5 - Compression 2 - Button 3 - Sealing Screw 6 - Deflector * 7 - Ejection Assembly 4 - Bulb Spring 7/16" ESCUTCHEON (11,1 mm) PLATE SEATING NOMINAL SURFACE 1I2 * MAKE-IN 4 •si (57,2 'i mm) WRENCH FLATS 4' SHOWN SHOWN CROSS PENDENT UPRIGHT SECTION FIGURE 11 STANDARD RESPONSE SERIES TV-B STAINLESS STEEL VERTICAL SIDEWALL (TY8491) SPRINKLERS SMO VERTICAL SIDEWALL (TY8492) SPRINKLERS TITANIUM VERTICAL SIDEWALL (TY8493) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT Components: * Temperature rating ** Pipe thread connections 1 - Frame * 5 - Compression is indicated on per ISO 7-1 can be 2 - Button Screw deflector or adjacent provided on special 3 - Sealing 6 - Deflector * to orifice seat on request. Assembly 7 - Ejection frame. 4 - Bulb Spring ARROW MUST POINT AWAY -< 7/16' FROM AND BE (11,1 mm) PERPENDICULAR NOMINAL TO THE BACK NPT j * 1/2' ** MAKE-IN WALL SURFACE I 6 7,2m11) 2 1/4 - WENCH- FLATS - \7 1* ENCH (5 3 SHOWN SHOWN CROSS PENDENT UPRIGHT SECTION FIGURE 12 QUICK RESPONSE SERIES TY-FRB STAINLESS STEEL VERTICAL SIDEWALL (TY8481) SPRINKLERS SMO VERTICAL SIDEWALL 'TV8482) SPRINKLERS TITANIUM VERTICAL SIDEWALL (TY8463) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT el to the ceiling. The word 'TOP" on the Deflector is to face towards the ceiling. Vertical sidewall sprinklers are to be in- stalled in the pendent or upright position with the arrow on the Deflector pointing away from the wall. Step 211). With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3D. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 16). With reference to Figures 9, 10, 11, and 12 the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats. Series TV-B and TV-FRB Recessed Horizontal Sidewall Sprinklers The Series TY-B and TY-FRB Recessed Horizontal Sidewall Sprinklers must be installed in accordance with the follow- ing instructions: - Step 1E. Recessed horizontal sidewall sprinklers are to be positioned in the horizontal position with their centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling. Step 2E. After installing the Style 10 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to • the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step 3E. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 17). With reference to Figures 9 and 10 the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats. Step 4E. After the wall has been installed or the finish coat has been applied, slide on the Style 10 Closure over the sprinkler and push the Closure over the Mounting Plate until it comes in contact with the wall. 2 (57, * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. ARROW MUST POINT AWAY FROM AND BE PERPENDICULAR TO THE BACK WALL SURFACE ** Pipe thread connections per ISO 7-1 can be provided on special request. 2-7/8 DIA. (73,0 mm) 5/8±1/4 3" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) SPRINKLER - PLATE FITTING 1/8" FACE OF MOUNTING '?- I (3,2 mm) \ MOUNTING SURFACE / CLOSURE SERIES -B or -FRB 1-5/16" (33.3 mm) (TY-FRB SHOWN) 13/16" (20,6 mm) FIGURE 13 SERIES TV-B OR TY-FRB PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 7~_ (57,2 mm) 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4(19,1 mm) (15,9±6,4 mm)2-1/4" DIA. 1/4" (6,4 mm) -H I FACE OF MOUNTING SPRINKLER PLATE FITTING j2mm) MOUNTING / SURFACE / CLOSURE SERIES -B or -FRB 1-3/8" (34,9 mm) (TY-FRB SHOWN) 7/8" (22,2 mm) FIGURE 14 SERIES TV-B OR TY-FRB PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT S TFP68O Page 14 of 16 products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are recom- mended to be initially performed for corrosion resistant sprinklers, after the installation has been completed, to verify the integrity of the corrosion resistant ma- terial of construction. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close- up visual inspections should be made, so as to better determine the exact sprinkler condition and the long term integrity of the corrosion resistant material of con- struction, as it may be affected by the corrosive conditions present. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdic- tion. Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. S Care and Maintenance The TYCO Series TY-B and TY-FRB Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprinklers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent operation may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise al- tered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive 5/8±1/4 -1 -- (15,9±6,4 mm) FACE OF MOUNTING SURFACE -------- SPRINKLER FITTING CLOSURE 2-7/8" DIA. SERIES-B (73,0 mm) PLATE mm) /4" DIA. ORTY-FRB 21 MOUNTING (3,2 mm) 1-5/16" (33,3 mm) 3/4" (19,1 mm) 13/16" (20,6 mm) 1/4" (6,4 mm) FIGURE 15 SERIES TV-B OR TY-FRB HORIZONTAL SIDEWALL SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6K-FACTOR, 1/2 INCH NPT WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 16 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS k 7 H PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 17 W-TYPE 7 SPRINKLER WRENCH TFP68O Page 15 of 16 -- Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: (specify SIN), (specify Standard Response or Quick Response), (specify K-factor), (specify) temperature rating, (specify Pendent Upright, C/UP, HSW, or VSW) Sprinkler with (specify type mate- rial: Stainless Steel, SMO, or Titanium), P/N (specify from Table E) Recessed Escutcheon Specify: Style (10 or 40) Recessed Es- cutcheon with (specify material or fin- ish*), P/N (specify) Refer to Technical Data Sheet TFP770. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 0 S TFP68O Page 16 of 16 P/N 57 - XXX - 0 - XXX - SUFFIX TEMPERATURE RATING MATERIAL 135 135°F (57°C) None Si ainles Steel 155 155°F (68°C) M SMO (5.6K Only) 175 175°F (79°C) T Titanium (5.6K Only) 200 200°F(93°C) • • TABLE SERIES TV-B AND TY-FRB SPRINKLERS ALTERNATE MATERIALS OF CONSTRUCTION AND PART NUMBER SELECTION SR -STANDARD RESPONSE 570 TV-B 5.6K UPRIGHT SR 590 TV-B 8.0K UPRIGHT SR 571 TV-B 5.6K PENDENT SR 591 TV-B 8.0K PENDENT SR 573 TV-B 5.6K C/UP SR 286 286-F (141-C) 593 TV-B 8.0K C/UP SR 360 360°F (182°C)° 578 TV-B 5.6K HSW SR TY-B-Only 575 TV-B 5.6K VSW SR OR - QUICK RESPONSE 370 TY-FRB 5.6K UPRIGHT OR 390 TY-FRB 8.0K UPRIGHT OR 371 TY-FRB 5.6K PENDENT OR 391 TY-FRB 8.0K PENDENT OR 373 TY-FRB 5.6K C/UP OR 393 TY-FRB 8.0K C/UP OR 378 TV-FRB 5.6K HSW OR 375 TY-FRB 5.6K VSW OR GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 19446 Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is a trademark of The DuPont Corporation Fire Protection Products 254 SMO is a trademark of Avesta Sheffield. S . Compatible with standard escutc and LA! & RFll cover plates Available in white, chrome, & brass finishes Great solution for seismic conditions Also used with adjustable drops With a 4-3/4" outside diameter,Tyco Wide Adapter Plates are a great, aesthetic solution to cover openings larger than the diameter of regular escutcheons or LFll & RFII cover plates. Finish Signal White (RAL 9003) Chrome Brass Part Number 10033601 10033602 10033603 Tyco Fire Protection Products www.tyco-fire.com All brand names, product names or trademarks belong to their respective owners. Tyco Fire Protection Products reserves the right to change product design and specifications without notice. Copyright © 2015 Tyco Fire Products LP. All rights reserved. / Technical Services - Phone: 800-381-9312 Fax: 800-791-5500 1FP2015008 S S L1 OIkYAlJA Bull Moose Tube® is a customer focused, growth oriented manufacturer and marketer of tubular products, where success is based on a commitment to meeting the customer's perception of quality. Our strength resides in our people working together to satisfy customers and to promote business growth by achieving superior financial performance. www.BullMooseTube.com sales@bullmoosetube.com 800.325.4467 c®us LISTED APPROVED £m..10.nFk. NFPA EN BULL MOOSE TUBE COMPANY Bull Moose Tube's® "Eddy Pipe®" brand sprinkler pipe is produced to meet sprinkler pipe standards and applications. c®us LISTED APPROVED ] ,,A - ONFSA FPA ADVANTAGES OF BULL MOOSE TUBES EDDY PIPEO FAMILY All pipe products are UL Listed (for U.S. and Canada), and have been approved by Factory Mutual. Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. All products are certified to ASTM Al 35 and A795 Type E, Grade A. Available in specific cut to order lengths from regular mill rollings. More popular sizes available with coating or bare. Ultra Eddy®, Eddy Flow®, Eddylite®, and Eddythread 40® offer cost savings along with superior hydraulics without compromising service life. Sprinkler pipe inventory stocked in Masury, Ohio; Gerald, Missouri; Casa Grande, Arizona; Kent, Washington; and Dallas, Texas. All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD Il® MIC preventative coating. Bull Moose Tube® sprinkler pipe is FBCTM compatible. PRODUCTS Schedule 10 and Schedule 40: FM approved and UL listed sprinkler pipe. Eddythread 40®: Light threadable Schedule 40 replacement with corrosion resistance ratio of 1.0. Eddylite®: I ightwll threadhle with standard outside diameter. Eddy Flow®: Cost effective replacement for crhedil 10. Ultra Eddy: Lightwall roll groovable pipe. Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. PROTECTION Eddy Guard Il®: Bull Moose Tube® is producing product that can resist bacteriological growth even after multiple rinse-outs. You know MIC corrosion can impact your installation and your property. Specify Bull Moose Tube® "Eddy Guard Il®" and feel comfortable knowing that you are getting Eddy Pipe® product you trust with the bacteria resistance you need. Eddy Guard Il® is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information contained herein is accurate as known at the time of publication. Bull Moose Iube& reserves the right to change product specifications without notice and without incurring obligation. c®us LISTED APPROVED []4,ONFSA NFPA SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 1-1/4 1.660 1.442 9.91 1.81 lbs/ft 2.518 61 1-1/2 1.900 1.682 7.76 2.09 lbs/ft 3.053 61 2 2.375 2.157 6.27 2.64 lbs/ft 4.223 37- 2-1/2 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 3 3.500 3.260 3.54 4.34 lbs/ft 7.957 19 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 1-1/4 1.660 1.380 1.00 2.27 lbs/ft 2.918 51 1-1/2 1.900 1.610 1.00 2.72 lbs/ft 3.602 44 2 2.375 2.067 1.00 3.66 lbs/ft 5.114 30 21/2* 2.875 2.468 1.00 5.80 lbs/ft 7.875 30 3* . 3.500 3.068 1.00 7.58 lbs/ft 10.783 19 4* 4.500 4.026 1.00 10.80 lbs/ft 16.316 19 *Only available in Casa Grande, AZ **Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak tight scat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. C:~, For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 8 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masury OH BULL MOOSE TUBE COMPr'JV 63017 Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose lube's Schedule lU and Schedule 40 pipes are hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. Shanghai Huaerde Stainless Steel Pipe Manufacture Co., Ltd. A PED& AD2000-W Certified Company Chihua Road, Shanghai Chemical Industry Park(Section B) so Fengxian District, Shanghai.201417 China Mill Test Report P IVA # HED-99137- 01 H*11A According to EN 10204 - 3.1 ;ustomer Name Silbo Industries, Inc. Material Specification I ASTM/ASME NSA 312-07, ASTM A 376-06 NACE MR01 75 TP304/304L '.0. No. 98137 Heat Treatment Solution Annealed and Quenched by water )escription I_Cold Finished Seamless Stainless Steel Pipes, Heat No. YX0903-401 Annealed& Pickled, Plain Ends, Length 20FT ELEMENTS Ni L N Yield Strength Tensile Elongation Hardness HRB lFlCATt0N Max 0.035 Max 200 Max 0M45 Max oo Max ;d ; Strength Min.205 MPa Min.515 MPa Min.35% Max.90 ILTS(LADLE) 0.021 0.64 0.023 0.006 0.399 18.22 8.26 - 09-24--098 330 625 48% 82 ILTS(PRODUCT) 0.020 0.66 0.029 0.005 0.395 18.24 8.29 09-26-135 337 626 49% 78 09-26-100 332 563 56% 74 09-24-101 340 574 55% 78 09-28-066 325 615 58% 72 09-29-018 318 627 50% 79 d of material delivery Hydrostatic Test, NOT and Dimensional check, etc. FT Piece Descriptions Heat No. Lot No. Testing Item Details Results 520 26 1-1/2" SCH40S YX0903-401 09-24--098 Dimensional / Visual ASTM A999/A999M Satisfactory 200 10 2" SCH80S YX0903-401 09-26-135 Hydrostatic Pressure Test ASTM A999/A999M Satisfactory 500 25 SCH40S YX0903-401 09-26-100 Eddy Current Test ASTM A999/A999M Satisfactory 200 10 SCH80S YX0903-401 09-24-101 Flaring Test ASTM A999/A999M Satisfactory 300 1 15 3" SCH40S YX0903-401 09-28-066 Flattening Test ASTM A999/A999M Satisfactory 100 1 5 SCH40S YX0903-401 09-29-018 Inter-granular Corrosion test ASTM A262 Practice E Satisfactory Making Process ical Furnace nent weld repair performed for billet and pipe Materials have been manufactured ,tested and examined in acc. with all the requirements of the ordered standards and we confirm that all test results are acceptable. Date July 10th, 2009 Mill inspector Li Bin Approved by QC manager Huang Ming 0 Page 1 o• 0 SM1TH_,.,C00PEJ1t I NTERNATIONAL CERTIFICATE OF CONFORMANCE PRODUCTS SOLD BY SMITH-COOPER INTERNATIONAL, LLC ARE MANUFACTURED, CERTIFIED AND SUPPLIED IN ACCORDANCE WITH THE FOLLOWING NATIONALLY RECOGNIZED SPECIFICATIONS AND STANDARDS: CAST IRON FLANGED FITTINGS, CLASS 125 & 250 Grey Iron Castings conform to ASTM A126 and ASTM A48 Flanged Fitting Dimensions conform to ASME B16.1 and ANSI!AWWA CI1O/A21.10 Flange faces are serrated per MSS SP-6, Class 250 flanges are raised face Hot-Dipped Galvanizing conforms to ASTM A153 CLASS 125 Fittings are UL LISTED through 12" Manufacturing Facility is ISO 9001:2008 CAST IRON FLANGES, CLASS 125 & 250 Grey Iron Castings conform to ASTM A126 and ASTM A48 Flange Dimensions conform to ASME B16.1 Flange faces are serrated per MSS SP-6, Class 250 flanges are raised face Hot-Dipped Galvanizing conforms to ASTM A153 Flange Threads conform to ASME 13I.20.1 Manufacturing Facility is ISO 9001:2008 S CAST IRON THREADED FITTINGS Grey Iron Castings conform to ASTM A126 Cast Iron Fitting Dimensions conform to ASME B16.4 Class 125 NPT Threads on fittings conform to ASME 131.20.1 Cast Iron Threaded Fittings are UL LISTED and FM APPROVED at 300psi Manufacturing Facility is ISO 9001:2008, ISO 14001 and BS EN 10204 TYPE 3.1 Cast Iron Fittings have SCI Trademark and are 100% Air Tested DUCTILE IRON THREADED FITTINGS Ductile Iron Castings conform to ASTM A536 Ductile Iron Fitting Dimensions conform to ASME B16.3, Class 150 Ductile Iron Bushings and Plugs conform to ASME B16.14 NPT Threads on all fittings conform to ASME 1131.20.1 Ductile Iron Threaded Fittings are UL LISTED and FM APPROVED at 500psi Ductile Iron Threaded Fittings are steam rated at 300psi saturated steam Manufacturing Facility is ISO 9001:2008, 150 14001 and BS EN 10204 TYPE 3.1 Ductile Iron Fittings have SCI Trademark and are 100% Air Tested MALLEABLE IRON THREADED FITTINGS, CLASS 150 & 300 Malleable Castings conform to ASTM A197 Hot-Dipped Galvanized Fittings conform to ASTM A153 Malleable Fitting Dimensions conform to ASME B16.3 Malleable Bushings, Plugs and Locknuts conform to ASME 11316.14 Malleable Unions conform to ASME B16.39 NPT Threads on all fittings conform to ASME 131.20.1 Class 150 fittings are UL listed and FM approved at 300psi Class 300 fittings are UL listed S Manufacturing Facility is ISO 9001:2008, ISO 14001 and BS EN 10204 TYPE 3.1 CHINA fittings have SCI Trademark and are 100% Air Tested *Galvanized Fittings are approved to ANSI/NSF 61-4 Annex G and CA AB1953 (<0.25% Lead) CERTIFICATE OF CONFORMANCE Page 2 S GROOVED COUPLINGS AND FITTINGS Grooved Coupling Housing and Fitting material conform to ASTM A536 Groove dimensions conform to AWWA C606 Grooved Coupling Bolts conform to ASTM A183 Galvanized Couplings and Fittings conform to ASTM A153 Manufacturing Facility is ISO 9001:2008 MERCHANT STEEL STANDARD AND RECESSED COUPLINGS & FITTINGS Merchant Coupling dimensions and materials conform to ASTM A865 Merchant Coupling threads conform to ASME 13I.20.1, Standard Couplings from 1/8" to 2" are NPSC (Straight Threads), 2-1/2" and larger are NPT (Tapered) Recessed Couplings are API 5L approved for extra heavy pipe, all sizes have NPT threads Merchant Steel bushings and plugs conform to ASME B16.14 Manufacturing Facility is ISO 9001:2008 FORGED STEEL FITTINGS & OUTLETS Forged Steel Fitting Material conforms to ASME SAIO5N,NORMALIZED Forged Steel Fitting Dimensions conform to ASME B16.I1 NPT threads on Forged Steel Fittings conform to ASME BI.20.I Forged Steel Socket Weld Inserts conform to MSS-SP-79 Forged Steel Unions conform to MSS-SP-83 Forged Steel Outlet Fittings conform to MSS-SP-97 Manufacturing Facility is ISO 9001:2008 and BS EN 10204 TYPE 3.1 STEEL WELDED NIPPLES SCH 40 & SCH 80 Black and Hot-Dipped Galvanized Steel Pipe used conforms to ASTM A53 5 Welded Steel Nipples conform to ASTM A733 NPT threads on nipples conform to ASME 131.20.1 Manufacturing Facility is ISO 9001:2008, ISO 14001 and BS EN 10204 TYPE 3.1 Import Nipples have SCI Trademark and tracking number Domestic Nipples available upon request *Galvanized Nipples are approved to ANSI/NSF 61-4 Annex G and CA AB1953 (<0.25% Lead) STEEL SEAMLESS NIPPLES SCH 40, SCH 80 & XXH Seamless Steel Pipe used conforms to ASTM A106 Grade B and ASTM A530 Seamless Steel Nipples conform to ASTM A733 NPT threads on nipples conform to ASME B1.20.1 Manufacturing Facility is 150 9001:2008, ISO 14001 and BS EN 10204 TYPE 3.1 Import Nipples have SC! Trademark and heat number Domestic Nipples available upon request BRONZE THREADED FITTINGS CLASS 125 & 250 (THAILAND and CHINA) Bronze Fittings conform to AWWA C800 Bronze Castings conform to ASTM B584, ASTM B62, UNS Alloy C83600 Bronze Fitting Dimensions conform to ASME B16.15 NPT Threads on all fittings conform to ASME 13I.20.1 Bronze Unions conform to specification A-A-59617 Manufacturing Facilities are ISO 9001:2008 CHINA fittings have SCI Trademark and are 100% Air Tested "NO LEAD" BRONZE THREADED FITTINGS CLASS 125 Bronze Fittings conform to AWWA C800 S Bronze Castings conform to ASTM B584, UNS Alloy C89833 Bronze Fitting Dimensions conform to ASME B16.15 NPT Threads on all fittings conform to ASME B1.20.1 Bronze Unions conform to specification A-A-59617 Manufacturing Facilities are ISO 9001:2008 Fittings have SCI Trademark and are 100% Air Tested *Approved to ANSI/NSF 61-4 Annex G and California AB 1953 (<0.25% Lead) CERTIFICATE OF CONFORMANCE Page 3 BRONZE FLANGES CLASS 150 (THAILAND and CHINA) Bronze Castings conform to ASTM B584, ASTM B62, UNS Alloy C83600 Bronze Flange Dimensions conform to ASME 816.24 NPT Threads on all flanges conform to ASME BI.20.1 Manufacturing Facilities are ISO 9001:2008 SEAMLESS RED BRASS NIPPLES (Schedule 40 Seamless Brass Nipples conform to AWWA C800 Seamless Brass Pipe conforms to ASTM B43, UNS Alloy C23000 Seamless Brass Nipples conform to ASTM B687 NPT threads on nipples conform to ASME 13I.20.1 *Approved to CA 1953 (<0.25% Lead) STAINLESS STEEL THREADED & SOCKET-WELD FITTINGS, TYPE 304 & 316, CLASS 150 & 1000 Stainless Castings conform to ASTM A351 Stainless Wrought Fittings conform to ASTM A182, Barstock to ASTM A276 Stainless Fitting Dimensions conform to MSS SP-1 14 (except Wall & Bands) NPT Threads conform to ASME 13I.20.1 Stainless Fittings have SCI Trademark Manufacturing Facility is ISO 9001:2008 STAINLESS STEEL FORGED FITTINGS & OUTLETS. TYPE 304 & 316 Forged Stainless Steel Material conforms to ASME A182 Forged Stainless Steel Fitting Dimensions conform to ASME 816.11 NPT Threads conform to ASME BI.20.1 Socket Fittings conform to ASME B16.11 Forged Stainless Union conform to MSS SP-83 Forged Stainless Outlets conform to MSS SP-97 Forged Stainless SW Inserts conform to MSS SP-79 Manufacturing Facility is ISO 9001:2008 and BS EN 10204 TYPE 3.1 STAINLESS STEEL FORGED FLANGES. TYPE 304 & 316. ALL CLASSES Forged Stainless Steel Material conforms to ASME A182 Forged Stainless Steel Flange Dimensions conform to ASME B16.5 NPT Threads conform to ASME B1 .20.1 Manufacturing Facility is ISO 9001:2008 STAINLESS STEEL MSS CAST FLANGES. TYPE 304 & 316. CLASS I50LW Cast Stainless Steel Material conforms to ASME A351 Flange Dimensions conform to MSS SP-51 NPT Threads conform to ASME B1.20.1 Manufacturing Facility is ISO 9001:2008 STAINLESS STEEL PLATE FLANGES, TYPE 304 & 316 Plate Stainless Steel Flange Dimensions conform to ASME 816.5 Class 150 Plate Stainless Steel Flanges made from ASTM A240 Plate or cast in conformance with ASTM A351 STAINLESS STEEL BUTT WELD FITTINGS. TYPE 304 & 316. ALL SCHEDULES Stainless Weld Fittings conform to ASTM A403, ASTM A960, MSS SP-43; (ASTM A774 available on request) Stainless Weld Fitting Dimensions conform to ASTM B16.9 (except Wall) and MSS SP-43 Stainless Weld Fittings have SCI Logo Manufacturing Facility is ISO 9001:2008 01 STAINLESS STEEL INSTRUMENTATION (COMPRESSION) FITTINGS Fittings meet ASME B31.1, ASME 1331.3, ASME Section VIII Fitting wall thickness conforms to SAE-J-514 NPT pipe threads conform to ASME BI.20.1 Fitting materials conform to ASTM A-276 (Barstock) or ASTM A- 182 (Forgings) CERTIFICATE OF CONFORMANCE Page 4 STAINLESS STEEL PIPE, WELDED & SEAMLESS, TYPE 304 & 316, ALL SCHEDULES Welded & Seamless Pipe material conforms to ASTM A312, ASTM A999; (ASTM A778 available on request) Stainless Pipe Dimensions conform to ASTM A999, ASME B36.19, ASME B36.10 Manufacturing Facility is ISO 9001:2008 STAINLESS STEEL NIPPLES. WELDED & SEAMLESS. TYPE 304 & 316. ALL SCHEDULES Stainless Steel Nipple Material conforms to ASTM A312 Stainless Steel Nipple Dimensions conform to ASTM A733 and ASME B36.19 NPT Threads on Stainless Nipples conform to ASME BI.20.1 Manufacturing Facility is ISO 9001:2008 STAINLESS STEEL TUBING, WELDED & SEAMLESS, TYPE 304 & 316 Stainless Steel tubing dimensions and materials conform to ASTM A269 and ASTM A249 Mark Martelle Product Engineer Revision: 4/13/16 CMt.xi T[[L [TL1© GRUVLOK STAINLESS STEEL FITTJNGS TYPE. 316 Gruvlok Schedule 10 Stainless Steel Fittings are segmentally welded with ends grooved to Gruvlok specifications. The standard material is 316 Stainless Steel unless otherwise noted with 304SS and/or Schedule 40 optional. Installation is quick and easy with the Gruvlok Figure 7400S5 Coupling, or other Gruvlok product. D FIG. 7050SS O FIG. 7051SS 0 FIG. 7060SS 0 FIG. 7074SS 900 Stainless Steel Elbow 45° Stainless Steel Elbow Stainless Steel Tees Stainless Steel Caps Type 316 Type 316 1ipe 316 Type 316 T1T 44L0D UiL H E to E Cto S CtoE 90'STAINLESS FIGURE 705OSS STEEL ELBOWiiii Nominal Center Approx. Size to End* Wt. Ea. IniON(nim) lnimm Lbs/Kg 1¼ 3% 1.2 32 98 05 1½ 4¼ 1.4 40 108 0.6 2 4 /8 2.3 50 711 LU 2½ 5A 3.3 65 746 7.5 3 5% 4.6 50 149 2.! 4 71/2 7.9 1011 197 3/! 6 10/4 17.0 75(1 273 77 8 15 29.4 200 331 /3.4 10 18 41.8 250 157 78.9 12 21 46.5 300 333 211 I1II1l I1iI ISYAY4 Nominal Center Approx. Size to End* M. Ea. IniDN(mm) In./mm Lbs/Kg 1¼ 2½ 0.7 32 34 0.J 1½ 2½ 0.9 .70 64 04 2 2½ 1.5 50 64 07 21/2 3 1.9 65 '0 09 3 3% 3.3 80 86 7.5 4 4 5.4 100 /02 2.4 6 51/2 11.2 751) 140 5.1 8 71/4 19.8 /87 10 81/2 21.0 250 2/6 05 12 10 23.0 300 254 /04 C to E FIGURE STAINLESS 70605S STEEL TEE Nominal Center Approx. Size to End* Wt. Ea. !nJDN(mm) InJmm Lbs/Kg 1¼ 23/4 1.5 32 10 07 1½ 21/4 1.8 40 ;'o 0.8 2 31/4 2.4 50 83 1.7 21/2 33/4 4.0 65 35 /.3 3 41/a 5.8 80 /08 2.6 4 5 10.3 100 127 4.7 6 6½ 25.7 150 765 II.? 8 73/4 41.1 200 13, /8.6 10 9 36.0 250 229 /6.3 12 10 48.4 254 22.0 FIGURE STAINLESS 7074SS STEEL CAP Nominal Center Approx. Size to End* Wt. Ea. /nJ011(mm) InJrnm LbsfKg 1¼ 1% 0.4 32 1 0.2 1½ 1% 0.5 40 4! 0.2 2 1% 0.8 50 4/ 0.4 2½ 1/4 1.1 85 43 (1.5 3 1% 1.6 70 45 0.7 4 1% 2.8 100 45 1.3 6 17/8 3.7 750 48 7.7 8 21/4 8.8 200 37 4.0 10 21/4 12.1 250 57 5.5 12 21/4 17.3 3% 57 7.8 O Notes: N SF 1 *Dimensions may duller from those shown above. Contact an Anvil Representative for more information. Fabricated fillings weights are based on Schedule 10 pipe. Fabricated Schedule 10, 316SS and Schedule 40 Center to End dimensions are the same. The pressure rating for the Gruvlok Schedule 10 Stainless Steel Fittings are equal to the pressure rating of the coupling used on Schedule 10 pipe as shown in the Working Pressure Ratings Chad for Stainless Steel Roll Grooved Pipe on page 169. Center to End dimensions differ from the 304 A Series, when ordering verify if 304 dimensions are required. PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: [-]Approved as noted Contractor: 0 Not approved ngineer: Remarks: Submittal Date: Notes 1: Notes 2: GL-9.15 UM039 LUL1 1E E FIG. 7OOSS Rigidlite® Coupling The Gruvlok Figure 740055 coupling is available in 11/4" - 8" sizes. The standard material is ASTM A 743 CF8M (Type 316) cast stainless steel which is ideal for corrosive environments. Any Gruvlok gasket material may be utilized in the 7400SS coupling for a broad array of applications. Gasket properties are as designated in accordance with ASTM D 2000. The 7400SS is provided with ASTM A 193 138M bolts and ASTM A 194 Grade 8M nuts. MATERIAL SPECIFICATIONS STAINLESS STEEL BOLTS & NUTS: Hex head stainless steel bolts, Type 316 per ASTM A 193 Grade 88M class 1 and heavy hex stainless steel nuts, Type 316 per ASTM A 194 Grade 8M class 1. Nuts and bolts are zinc plated to prevent common thread galling. Contact an Anvil Representative for more information. HOUSING: Cast Stainless Steel (Type 316) - ASTM A 743 CF8M GASKETS: Materials Properties as designated in accordance with ASTM D 2000 0 Grade 'EP" EPDM (Green and Red color code) -40"F to 250"F (Service Temperature Range)(-40'C to 121"C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. FIGURE 740OSS - RIGIDLITIE STAINLESS STEEL COUPLING - I Max. I Max. I Range of Coupling Dimensions Coupling Bolts* Approx.Nornina ified 0.0. Wk. End Pipe End que Wt. Si Pressuret Loadt separation X Y Z QtV Size Max. Fft-Lbs.IN-m lnJmm PSI/bar LbsikN lnimm lnJmm lnimm lnimm InJmm lnimm LbslKg 11/4 1.660 300 649 0-½2 27/u 4'/u 1/4 2 3/u x 2¼ 20 1.6 32 42.4 20.7 2.89 00.79 73 705 44 - M10x57 21 27 0.7 11/2 1.900 300 851 0-½2 31/8 41/8 1/4 2 3/ux2¼ 15 20 1.7 40 48.3 20.7 3.78 0-0.79 79 117 44 M10x57 21 27 0.8 2 2.375 300 1,329 0-½2 35/8 5% 1/4 2 %x 21/4 15 20 2.1 50 60.3 20.7 5.9, 0-0.79 92 137 45 M10K5721271.0 21/2 2.875 300 1,948 0-Y32 41/8 5/u 1/4 2 %x2¼ 15 20 2.3 65 730 20.7 8.66 0-0.79 105 149 44 M70x57 21 27 7.0 3 3.500 300 2,886 0-1/32 4°/u 6/8 1/4 2 ½ x 2/4 50 60 3.1 30 88.9 20.7 12.84 (70.79 117 153 44 M12.70 68 80 1.4 4 4.500 300 4,771 0-3/32 6 73/4 1% 2 1/2 x 2/4 50 60 4.4 100 114.3 20.7 21.22 1 0-2.38 152 797 48 - M12x70 68 80 2.0 6 6.625 275 9,480 0-3/32 81/8 111/8 2 2 3/4 x 3 .80 100 7.8 150 768.3 19.0 42.17 0-2.38 206 283 51 M20x76 110 750 3.5 8 8.625 275 16,067 0-3/32 10/8 13/8 23/e 2 3/4 x 3 80 100 13.2 200 219.7 19.0 71.47 0-2.38 264 346 60 M20x76 110 150 6.0 0 Grade "T" Nitrile (Orange color code) -20'F to 180'F (Service Temperature Range) (-29"C to 82"C) Recommended for petroleum applications, air with oil vapors and vegetable and mineral oils. NOT FOR USE IN HOT WATER OR HOT AIR. II••i1' i•i L!!IL 11!! [11111 CAUTION: Contact your local Anvil representative for corrosive application environments. No coatings or zinc options. All bolts are hex head design Type 316 Grade B8M Class 1 stainless steel to ASTM A 193, with Type 316 Grade 8M stainless steel heavy hex nuts conforming to ASTM A 194. Use of suitable anti-galling thread compound is recommended. 0 Grade '0" Fluoro-Elastomer (Blue color code) 20"F to 300'F (Service Temperature Range)(-29"C to 149"C) Recommended for high temperature resistance to oxidizing acids, petroleum oils, hydraulic fluids, halogenated hydrocarbons and lubricants. 0 Grade "L" Silicone (Red color code) -40"F to 350"F (Service Temperature Range)(-40'C to 177'C) Recommended for dry, hot air and some high temperature chemical services. GASKET TYPE: 0 Standard C Style 0 Flush Gap (1.'/4"-8") LUBRICATION: 0 Standard Gruvlok 0 Gruvlok XtremeTM (Do Not use with Grade "L") t Ratings apply when used with Schedule 40 ASTM A 312 Type 304 stainless steel pipe for all sizes. Refer to ratings chart for additional data. Range of Pipe End Separation values are for roll grooved pipe and maybe doubled for cut groove pipe. PROJECT INFORMATION APPROVAL STAMP Project: JApproved Address: [:]Approved as noted Contractor: J Not approved ngineer: Not Submittal Date: Notes 1: Notes 2: GL-9.15 c®uS LISTED APPROVED Fe, U kegefAp5.oeal DOIAIC and Leniddofle. altO oU, webs 10 at eone.anvilntl.Com or contact en Anvil' Sales floprosenlative. _.\.. C. '..'... Clamp-T, FPT Branch The Gruvlok Clamp-T provides a quick and easy outlet at any location along the pipe. A hole drilled or cut in the pipe to receive the locating collar of the Clamp-T is all that is required. The full, smooth outlet area provides for optimum flow characteristics. The Clamp-T housing is specially engineered to conform to the pipe O.D. and the Clamp-T gasket providing a leak tight reliable seal in both positive pressure and vacuum conditions. The maximum working pressure for all sizes is 500 PSI (34.5 bar) when assembled on standard wall steel pipe. The Gruvlok Clamp-T provides for a branch or cross connection in light wall or standard wall steel pipe. The Fig. 7045 Clamp-T female pipe thread branch is available with NPT or ISO 7/1 connection and the Fig. 7046 Clamp-I has grooved-end branch connection. Clamp-T cross connections are available in various sizes allowing greater versatility in piping design. NOTE: Variable End Configurations are Possible - Thd x Thd and Gr. x Thd. Sizes — 2" x /2 through 8" x 4' CLAMP-T FLOW DATA RESISTANCE) (FRICTIONAL Fig. 7045 Threaded Branch Branch Size Inches CV Value Equiv. Pipe Length Feet ON/mm Meters 1/2 22 1.0 15 . 8.3 3/4 25 2.0 1 44 2.0 11/4 76 2.5 32 0.8 11/2 89 4.0 40 1.2 2 164 3.5 50 - 1.1 21/2 152 12.5 3 318 8.5 80 ______ 2.6 4 536 8.0 100 - 2.4 ? NSI BOLTS & HEAVY HE NUTS Heat treated, oval neck track head bolts conforming to ASTM A 183 • Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B, or J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. MATERIAL SPECIFICATIONS METRIC BOLTS & HEAVY HEX NUTS. Heat treated, zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts are zinc electroplated followed by a yellow chromate dip. U-BOLT Cold drawn steel and zinc plated. STAINLESS STEEL BOLTS & NUTS: Stainless steel bolts and nuts are also available. Contact an Anvil Representative for more information. HOUSING. Ductile Iron conforming to ASTM A 536, Grade 65-45-12 COATINGS. EJ Rust inhibiting paint - Color: ORANGE (standard) El Hot Dipped Zinc Galvanized (optional) D Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements Contact an Anvil Representative for more information. GASKETS: Materials Properties as designated in accordance with ASTM D 2000 U Grade "E" EPDM (Green color code) -405F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. Grade "EP" EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. For hot water applications the use of Gruvlok Extreme Temperature lubricant is recommended. NSF-61 Certified for cold and hot water applications up through 12' o Grade "T" Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications, air with oil vapors and vegetable and mineral oils. NOT FOR USE IN HOT WATER OR HOT AIR. LUBRICATION: Standard Gruvlok 0 Gruvlok XtremelM (Do Not use with Grade "L') PROJECT INFORMATION APPROVAL STAMP Project: 0 Approved Address: [-]Approved as noted I Contractor: i:j Not approved ngineer: Remarks: Submittal Date: Notes 1: Notes 2: GL-7.12 Fig. 7045 (U-Bolt) ©JX t•) Clamp-T, FPT Branch I-- I Fig. 7045 FIGURE BRANCH I(TABLE CONTINUES (.Jl*: lt1 I ' Hole Dimensions V Max. I Clamp-I Dimensions ' Specified Torque § 'pprOx Nominal Size O.D. Wt. Each Working z Bolt Size Mm. Diameter Max. Diameter Pressure I U V Threaded W V Mm. Max. InJL1N(mm) In 1mm InJmm Inimm PSI/bar InJmm In1mm InJmm In1mm In1mm In1mrn In1mm Ft-Lbs/N-rn Lbs/Kg 2 x 1/2 2.375 x 0.840 11/2 i/ 500 2%6 3'ie 2/e ½ 51/2 3 ½ U-Bolt 30 40 2.3 50x15 60.,,A '-'1. 3 38 41 34.5 56 14 67 12 140 76 - 1.0 2 x 3/4 2.375 x 1.050 11/2 1% 500 21A6 'e 2% 1½ 51/2 3 1/2 U-Bolt 30 40 2.3 50x20 60.3x26.? 38 41 34.5 52 14 67 38 140 76 - 1.0 2 x 1 2.375 xl .315 1½ 1% 500 115A6 9Ae 21/8 11/2 5½ 3 ½ U-Bolt 30 40 2.6 60.3x387 38 41 34.5 51 14 67 38 140 76 - 7.2 2 x 11/4 2.375 x 1.660 2 21/8 500 23/16 s/ut 2/8 1½ 5½ 31/2 1/2 U-Bolt 30 40 2.7 50x32 60.3x42.4 81 14 34.5 05 74 73 38 140 89 - 1.2 2 xl 1/2 2.375 x 1.900 2 21/8 500 23/16 /i 2/8 1½ 7 31/2 ½ U-Bolt 30 40 2.5 50A40 603x48.3 51 54 34.5 55 14 /3 38 1/il 89 - 1.1 21/2 x 1/2 2.875 x 0.840 11/2 1% 500 2Ae /16 2/u 13/4 5½ 3 1/2 U-Bolt 30 40 3.0 5.5xli 73.0x2!.3 38 41 34.5 62 14 73 44 14r- 21/2 x 3/4 2.875 x 1.050 1½ 1% 500 21/1e %6 2/8 13/4 5½ 3 ½ U-Bolt 30 40 2.9 (1520 73.0x267 33 41 3-15 59 14 /3 44 140 1 76 - 1.3 21/2 x 1 2.875 x 1.315 1½ 1% 500 23/16 /l6 2/u 13/4 61/8 3 ½ U-Bolt 30 40 2.9 63x25 73,0x33.7 38 41 34.8 05 74 ,3 44 156 76 .. 1.3 21/2 x 11/4 2.875 x 1.660 2 21/8 500 2Ae iu 31/8 13/4 6Ve 33/8 ½ U-Bolt 30 40 3.4 63'.32 I3(Ix42.4 51 54 34.5 132 14 /9 44 156 86 - 1.5 2½ x 1½ 2.875 x 1.900 2 21/8 500 27Ae 9Ae 31/8 1/4 61/u 3% ½ U-Bolt 30 40 3.4 65x40 73.0x48.3 51 54 34.5 62 13 79 64 156 86 - 1.5 3 x 3.500 x 0.840 1½ 1% 500 29A6 9/16 3 21/a 7 33/4 ½ U-Bolt 30 40 2.8 81/XIS 88.9X213 377 41 3-35 65 14 1 76 54 1 178 95 - 12 3 x 3/4 3.500 x 1.050 1½ 1% 500 27A6 8A6 3 21/8 7 33/4 ½ U-Bolt 30 40 2.7 $0r20 88.92(U 38 41 34.5 62 74 16 04 1/8 95 1.2 3 x 1 3.500 x 1.315 1½ 1% 500 25/16 %e 3 21/8 7 33/4 ½ U-Bolt 30 40 2.7 30y.25 88.Px$3./ 38 41 34.5 59 14 76 54 1733 95 1 1.2 3 x 11/4 3.500 x 1.660 2 21/8 500 2'Vie 1½ 3% 2½ 67/a 33/4 ½x 2/4 80 100 3.4 80x32 &3.9x62.4 51 54 34.5 68 38 66 54 175 90 - 1.5 3 x 1112 3.500 xl .900 2 21/8 500 2/ie 1½ 3% 2½ 6/u 33/4 ½ x 21/4 80 100 4.4 80o40 1 88.9r483 51 54 345 68 1 38 86 54 175 95 - 20 3 x 2 3.500 a 2.375 2½ 2% 500 2'1Ae 1½ 3/e 21/8 67/u 4½ ½ x 23/4 80 100 4.6 $0x50 89.9x60.3 64 67 34.5 68 38 86 04 175 11/5 2.1 4 x 4.500 x 0.840 1½ 1% 500 31A6 9/16 3½ 2% 73/4 31/4 Y2 U-Bolt 30 40 2.9 11/Ox 15 114.3x81.3 38 41 34.5 ill 1-1 89 6/ 19/ 315 - 1.3 4 x 3/4 4.500 x 1.050 1½ 1% 500 31A6 1/1 3½ 2% 73/4 33/4 ½ U-Bolt 30 40 2.8 100x20 114.3x26.7 38 41 34.5 78 14 89 67 197 95 4 x 4.500 x 1.315 1½ 11/8 500 29/1e 9/1e 31/2 2% 73/4 33/4 Y U-Bolt 30 40 2.7 iO3J25 1143,'. 33.7 38 41 345 73 14 89 6? 197 95 - 12 4 xl 1/4 4.500 x 1.660 2 21/6 500 33A6 11/8 3/8 2% 71/2 33/4 ½ x 23/4 80 100 4.5 70032 114.3x42.4 5! 54 34.5 81 43 98 67 191 95 - 2.0 4 x 11/2 4.500 x 1.900 2 21/8 500 33/16 17/8 3/u 2% 71/2 33/4 1/2 x 23/4 80 100 4.6 100740 114.3x48.3 51 .54 34.3' 81 48 98 07 1 191 95 - 2.1 4 x 2 4.500 x 2.375 2½ 2% 500 31/1e 17/8 4 2% 71/2 4½ ½ x 2% 80 100 7.7 100 '.-50 i;4.3x60.:I 64 67 34.5 84 48 102 67 191 105 - 3.5 4x2½ 4.500x2.875 23/4 2/u 500 311A6 1/8 4 2% 71/2 4% ½x2% 80 100 5.2 100x65 1I43x73.0 70 73 34.5 78 48 102 67 191 111 4x30.0. 4.51/0"u 2.996 21 27 500 3 ?5 4 ' 77. "PlI f, 73x21 80 100 5.2 100 x 80 114.3 x 76.1 70 73 34.5 76 48 102 67 191 111 - 2.4 4 x 3 4.500 x 3.500 3½ 3% 500 31/4 1/e 41/4 2% 7½ 5¼ ½ x 3½ 80 100 6.5 100x80 114.3x88.9 89 92 3-1.5 83 4$ 108 67 191 133 - 29 Based on use with standard wall pipe. 21/2", 5" and 6" Now. Run pipe size Clamp-T may be used on 30.0., 51h" O.D. and 61h" 0.0. pipe. § - For additional Bolt Torque information, see page 190. (Additional larger sizes on next page.) See Installation & Assembly directions on page 168. Not for use with copper systems. GL-6.11 S FIG, 74- Clamp-T, FPT Branch rig. iuq) Fig. 7045 (U-Bolt) bi,L ([1 i; FIGURE 704S-FPTiBRANCHN((CONTINUED iFROMIPREVIOUS I I Hole Dimensions V Max. Clamp-I Dimensions Specified Torque § Approx. Nominal Size O.D. Wt. Each Working Bolt Size Mm. Diameter Max. Diameter Pressure I U V Threaded W V Z Mm. I Max. !niON(rnrn) InJrnrn InJrnrn InJrnm PSI/bar InJmrn lnlmrn lnirnrn InJrnrn lnirnm InJrnrn InJrnrn FL-Lbs/N-m Lbsikg 5 xl 1/4 5.563 xl .660 2 21/8 500 3W,e 11/8 4% 31/4 91/8 33/4 % x 3'/4 100 130 5.4 725* 32 747.3,k 42.4 57 .54 34.5 94 48 II'! 83 232 95 - 2.4 5 x 11/2 5.563 x 1.900 2 21/8 500 3',/l6 1% 4% 31/4 91/8 33/4 % x 31/4 100 130 5.5 12,5.k 40 741.3*48.3 51 54 34.5 94 48 177 83 1 232 95 - 2.5 5 x 2 5.563 x 2.375 21/2 2/8 500 31/16 1/8 41/2 31/4 9'/e 41/8 5/ X 31/ 100 130 5.7 1271*50 !47.3,k 60.o 64 57 34.5 97 48 /14 83 232 /05 . 2.6 5 x 21/2 5.563 x 2.875 21/4 21/8 500 313Ae i/t 43/4 31/4 91/8 4% % x 31/4 100 130 7.0 125* 65 741,3X73.G. 70 73 34.5 97 48 121 83 232 111 - 3.2 5*30.!). 5.563*2.996 25 2" 500 3 I 4 3! 9>c 4,ê 7 130 180 70 125x80 141.3x76.1 70 73 1 34.5 95 48 121 83 232 111 - 3.2 5 x 3 5.563 x 3.500 31/2 31/8 500 4 17/8 5 31/4 91/8 51/4 % x 31/4 100 130 8.7 !25x80 147.3*88.9 39 92 34.5 102 48 727 33 232133 ' 3.9 6 x 11/4 6.625 x 1.660 2 21/8 500 43A6 2 41/8 31/8 101/8 33/4 % x 4¼ 100 130 7.8 750*32 /58.3*42.4 51 54 34.5 1077 51 124 98 25/ 95 - 3.5 6 x 11/2 6.625 x 1.900 2 21/8 500 43A6 2 41/8 37/8 101/ 33/4 1/8 x 41/4 100 130 7.8 150*40 108.3x48.3 51 54 34.5 106 *7 724 98 271/ 95 6 x 2 6.625 x 2.375 21/2 21/8 500 43A6 2 4% 31/8 10½ 41/8 % x 41/4 100 130 7.8 70x50 W3.3*60.3 64 07 34 106.5! 124 98 25/ 105 - 3.5 6x 21/2 6.625 x 2.875 23/4 2/e 500 4/16 2 51/8 31/8 101/8 43/8 1/8 x 41/4 100 130 8.4 750*65 /08.3x/3.0 70 73 34.5 706 1 51 1 130 98 257 11! " 3.8 7* $0.0. 0.025*2.996 V I 2 500 45r 2 5½ 37 10!5 4*7 *X 4 11 100 130 3.4 150x80 168.3x76.1 70 73 34.5 105 51 130 98 257 111 - 3.8 6 x 3 6.625 x 3.500 31/2 3% 500 4% 2 5% 31/8 101/8 51/4 % x 41/4 100 130 9.6 '150*80 68.3'y 85.9 89 92 34.5 /1! :/7 137 98 257 133 ' 4.4 6 x 4 6.625 x 4.500 41/2 4% 500 43/8 2 51/2 37/8 101/e 61/2 % x 41/4 100 130 , 10.5 /b0A 190 108.3L 174.3 714 71/ 34.3 711 51 140 03 . 25/ /65 - 4.8 8 x 2 8.625 x 2.750 21/2 25/8 500 53/16 2¼ 51/8 5 123/4 41/8 3/4 x 41/4 130 180 11.3 208*50 219.1*70.0 64 57 34.5 132 57 149 127 324 105 - 5.1 8 x 21/2 8.625 x 2.875 2/4 2% 500 51/16 2¼ 61/4 5 123/4 4% 3/4 x 41/2 130 180 11.1 LOO *65 21 ff. 1*73.0 70 73 34.5 734 57 159 727 324 II! " 5.0 11x30,0. 8.625 r2.9977 2/4 21 500 5'4 2½ 07 5 72½ 4½ "x" /30 780 ILl 200 x 80 219.1 x 76.1 70 73 34.5 133 57 159 127 324 111 - 5.0 8 x 3 8.625 x 3.500 31/2 3% 500 5% 21/4 6% 5 123/4 51/4 3/4 x 41/2 130 180 13.0 200 *80 279.1*88.9 89 92 34.5 ,37 57 162 ;27 324 133 8 x 4 8.625 x 4.500 41/2 41/8 500 5% 2¼ 6½ 5 12~ 6½ ~ x 4½ 130 180 16.2 200l00 219.1*113.3 /74 II? 34.5 737 :,I 165 127 324 7775 - 7.3 f/OTL. 21/2', 5" and 6" Nom. Run pipe size Clamp-I may be used on 3" 0.0., 51/2" 0.0. and 61/2' 0.0. pipe. (Additional smaller sizes on precious page.) Based on use with standard wall pipe. § - For additional Bolt Torque information, see page 190. See Installation & Assembly directions on page 166. Not for use with copper systems. - - GL-7.12 ') CAST DROI THREADED FITTINGS '41 1-1111-1111- Class 125 (Standard) S FIG. 3356 45° Elbow c®uS LISTED APPROVED ngs/Approval Details and Limitations, our website at Iww.anvilintLcom or act an Anvil* Sales Representative. S FIGURE 33.. :JsYY Nominal Size Maximum Dimension A Approx. Wt. Each Working PressureA In. (mm) PSI (kPo) In. (mm) Lbs. (kg) 300 1.12 0.84 75 2065 26.448 0.38 1¼ 300 1.29 1.40 11/2 300 1.43 1.80 40 2055 3&322 037 2 300 1.68 2.79 50 2065 42.672 1.25 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME BI 6.4 Class 125 Material: ASIM A126 Finish: Black or Hot Dip Galvanized per ASIM A153 Class A Threads: NPT per ASME 81.20.1 Agency Approvals: All cast iron threaded Fittings are UL/ULC Listed and FM Approved. IPROJECT IlIIINFORMATI ON APPROVAL STAMP r 0 Approved Approved as noted fl Not approved Remarks: Submittal Date: Notes 1: Notes 2: Class 125 (Standard) FIG. 3351 900 Elbow h— A I A L ISTED APPROVED s/Approval Details and Limitations, website at www.anvilinll.com or an Anvil* Sales Representative. CAST IRON THREADED FITTINGS iNVIL FIGURE 3c. :.'YiY Nominal Size MaximumDimension A Approx. Wt. Each Working PressureA In. (mm) PSI (kPo) In. (mm) Lbs. (kg) 1 300 1.50 0.84 25 2065 38.18 1 Y4 300 1.75 1.34 32 20o5 4445 061 11/2 300 1.94 1.80 40 2065 497 032 2 300 2.25 2.90 2/2 300 2.70 4.75 65 206.5 63.5P 2.15 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.4 Class 125 Material: ASTM A126 Finish: Black or Hot Dip Galvanized per ASTM A153 Class A Threads: NPT per ASME B1.20.1 Agency Approvals: All cast iron threaded Fittings are UL/ULC Listed and FM Approved. 1PROJECT IIIIINFORMATION ] Project: D Approved Address: ]Approved as noted Contractor: J Not approved ngineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Cl-1.15 P) CAST IRON THREADED FITTINGS L. iWIL Class 125 (Standard) C FIG. 3387 Cored Plug c®uS USTED APPROVED For Listings/Approval Details and Limitations, visit our website at www.anvilintt.com or contact an AnviP Soles Representative. C FIGURE 33:'A CORED PLUG Nominal Size Maximum Dimension A Approx. WI. Each Working PressureA In. (mm) PSI Oa) In. (mm) Lbs. (kg) 1/2 300 0.94 0.10 15 2065 23.87 0.05 Y4 300 1.01 0.17 20 20o5 2717 008 1 300 1.25 0.28 iS 2065 3.75 0.13 1 V 300 1.36 0.44 32 20o5 3454 020 lA 300 1.45 0.62 40 2065 36.83 0.78 2 300 1.56 0.91 SO 2065 39.62 041 A - Working Pressure Ratings are for reference only and based on Scn. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit onvilintl.com or contact your local Anvil Representative. * Port supplied as Solid Plug. Dimensions: ASME B16.14 Material: ASTM A126 Finish: Black or Hot Dip Galvanized per ASIM A153 Class A Threads: NPT per ASME B1.20.1 Agency Approvals: All cast iron threaded fittings are UL/ULC Listed and FM Approved. A Pressure Temperature Ratings in accordance with ASME B16.4 class 125 PROJECT INFORMATION APPROVAL STAMP Project: 0 Approved Address: []Approved as noted OContractor: 0 Not approved ngineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Cl-1.15 USTED APPROVED ir Listings/Approval Details and Limitations, visit our webs/a at vw.anvitntLcom or contact an Anvir6 Sales Representative. CAST IRON THREADED FITTINGS I- 'Y.ANVPL Class 125 (Standard) FIG. 3367 Reducing Coupling [e1I]:1 UJ.1II[c Nominal Size MaximumDimension A Approx. WI. Each Working PressureA In. (mm) PS! (kPo) In. (mm) tbs. (kg) 1 x ¼ 300 1.70 0.62 25x15 2065 43.18 0.28 1 x3h 300 1.70 0.80 25s20 2Oo 43.18 0.6 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit onvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.4 Class 125 Material: ASTM A126 Finish: Black or Hot Dip Galvanized per ASTM A153 Class A Threads: NPT per ASME B1.20.1 Agency Approvals: All cast iron threaded Fittings are UL/ULC Listed and FM Approved. PROJECT IIIIINFORMATION I Project: 0 Approved Address: IJ Approved as noted I Contractor: J Not approved ngineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/0-1 .15 CAST URON THREADED FaTINGS Class 125 (Standard) S FIG. 3351R Reducing 900 Elbow c®us USTED APPROVED or Listings/Approval Details and Limitations, visit our website at aww.anvilinticom Or contact an Anvil* Sales Representative. C FIGUR ccI. 1:1 REDUCIPJ113IJu :jsYY Max. Working Dimensions Approx. Nominal Size PressureA Wt. Each A B In. (mm) PSI (kPo) In. (mm) In. (mm) Lbs. (kg) lx 1/2 300 1.26 1.36 0.64 25.t15 2055 3200 34.56 029 1 x 300 1.31 1.45 0.87 1 1'hx 1/2 300 1.34 1.53 0.96 52x15 2065 34.03 3586 0.14 11/4 x 3/4 300 1.45 1.62 1.13 l¼xl 300 1.58 1.67 1.16 3 2 2055 4013 4241 0.53 lt/2X'/2 300 1.41 1.66 1.17 A t .53 11/2 x '/4 300 1.52 1.75 1.28 40x20 2065 53.60 44.45 0.58 1½x1 300 1.65 1.80 1.51 t ) 0 / 1/2 x 1¼ 300 1.82 1.88 1.62 4Q32 2045 4162? 4775 073 2 x 1/2 300 1.49 1.88 2.00 3/34 41.75 09, 2 x 3/4 300 1.60 1.97 2.05 5Thr20 2065 40ti4 5003 0.93 2 x 1 300 1.73 2.02 2.10 5025 20o$ 4394 51.30 0. 2 x 1/4 300 1.90 2.10 2.30 50r32 2065 4876 5334 - 04 2 x 11/2 300 2.02 2.16 2.60 50x40 2063 31.30 54.85 1.18 Dimensions: ASME B16.4 Class 125 Material: ASTM A126 Finish: Black or Hot Dip Galvanized per ASTM A153 Class A Threads: NPT per ASME B 1 .20. 1 Agency Approvals: All cast iron threaded fittings are UL/ULC Listed and FM Approved. A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest uL/uLc, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Pes 0 Approved Approved as noted i: Not approved Remarks: Submittal Date: Notes 1: Notes 2: SPF/CI-1 .15 f C F/ANVL CAST IRON THREADED FITTINGS fj1JNVIL Class 125 (Standard) FIG. 3358R Reducing Tee 1 2 3 1 x2x3 c®us LISTED APPROVED tings/Ppprovat Details and Limitations. Our website at vw.anviIiotL corn or tact an Anvir6 Sates Representative. I ErIIJ:]* :Jj:]::]1s1ufs4I[rI: Nominal Size Max. Dimensions Approx. working A 1x2x3 Pressurea, M D Wt. Each In. (mm) PSI (kPe) In. (mm) In. (mm) In. (mm) lbs. (kg) 1XV2 x 1 300 1.50 1.36 1.50 1.08 1 15445 2065 38 10 3464 3d.0 049 1 xY4xl 300 1.50 1.45 1.50 1.18 26r 30445 2065 1816 36.63 35)6' 054 lx lx 1/2 300 1.26 1.26 1.36 0.95 24425 2065 3300 326'O 3164 645 lxi xY4 300 1.37 1.37 1.45 1.10 25;n23x20 2(165 34.19 3419 344,5 050 lx 1 x 11/4* 300 1.67 1.67 1.58 1.52 25 244 32 20o5 42.418 42.418 40.151 0,69 1 x x 114* 300 1.8 1.8 1.65 1.73 25x25x'lO 1065 4572 1519 4691 013 1½x15/2 300 1.34 1.26 1.53 1.17 34424415 2065 3103 3206 36.86 053 11/4 x 1 x '/4 300 1.45 1.37 1.62 1.38 34425 20 21163 36.93 34.19 4!.i4 643 11/4 xix 1 300 1.58 1.50 1.57 1.47 32444425 2065 4013 38 11' 39.57 1167 1½x1 x1¼ 300 1.75 1.67 1.75 1.80 344 24432 2065 1445 63,41 14.45 .082 11/4 x lx 1 1/2* 300 1.88 1.8 1.82 2.05 744540, 2065 /./52 45.12 .228 093 Dimensions: ASME BI 6.4 Class 125 Material: ASTM A126 Finish: Black or Hot Dip Galvanized per ASTM A153 Class A Threads: NPT per ASME B1.20.1 Agency Approvals: All cast iron threaded Fittings are UL/ULC Listed and FM Approved. FIGURE 33..l: REDUCING TEE Nominal Size Max. Dimensions Approx. 1x2x3 Working Wt. Each D r PressureA U In. (mm) PSI (kPo) In. (mm) In. (mm) In. (mm) . lbs. (kg) 1¼ x 11/4 x ½ 300 1.34 1.34 1.53 1.37 3,232 15 20'19 3403 3403 3886 062 1½ x 1½ x V4 300 1.45 1.45 1.62 1.54 9'i7; 20 21'óS 36.83 .36.83 41.14 (670 1¼ x 1 '/4 x 1 300 1.58 1.58 1.67 1.65 32442445 2065 40.13 4013 42.41 0. 175 1½x 1½x 1½* 300 1.88 1.88 1.82 2.21 I 'r1 I" *1 1 1114 x 11/4 x 2* 300 2.1 2.1 1.9 2.55 25 445 .t 40 2065 5534 .5 3.34 4826 1.16 A Working Pressure Ratings are for reference only and based on Sc,. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as "Bull Head Tee. PROJECT INFORMATION APPROVAL STAMP O E 0 Approved LjApproved as noted U Not approved gineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Cl-1 .15 - CAST IRON THREADED FITTINGS AWIL Class 125 (Standard) FIG. 3358R Reducing Tee 11 2 1 x 2 x 3 [till:] *!cl.1:1 : REDUCIPJG TEE Approx. Nominal Size Max. Dimensions 1x2x3 Working Wt. Each A r Pressurea, In. (mm) MOM In. (mm) In. (mm) In. (mm) tbs. (kg) 11/2 X x 1/2 300 1.41 1.34 1.66 1.41 40x 25x iS 2065 35.61 340$ 42.16 064 11/7 x lx Y4 300 1.52 1.37 1.75 1.65 40x25x20 2065 38.60 34.19 44.45 035 1/2 x 1 x 1 300 1.65 1.50 1.80 1.65 40x25 f 25 2065 41.91 58W 45.12 0./S 1¼ x lx 1½ 300 1.82 1.67 1.88 2.00 40c25.32 2065 46.22 4241 47.75 011 1½x 1 x 1¼ 300 1.94 1.8 1.94 2.30 40x25x40 2065 49.27 45.72 49.21 1.04 11/2 x 1¼ x ¼ 300 1.41 1.34 1.66 1.58 40x32x 15 2065 35.81 34.03 42.16 0.72- 1 '/2 x 1½ x Y4 300 1.52 1.45 1.75 1.72 40x32 k 20 2065 33.60 36.83 44.15 0.16 1 /2 X 1½ x 1 300 1.65 1.58 1.80 1.85 40x32x25 2065 41.91 40.13 4.5.72 0.84 1¼ x 1¼ x 1¼ 300 1.82 1.75 1.88 2.22 40,t 32x$2 2065 46,22 4445 4715 1,00 1½ x 1¼ x 1¼ 300 1.94 1.88 1.94 2.45 40x32x 15 2065 1 49.27 47,75 49.27 lij 1½ x 11/4 x 2* 300 2.16 2.1 2.02 2.80 40x32k40 2055 54.864 53.34 51.508 1.27 1½x1¼x½ 300 1.41 1.41 1.66 1.76 40x40x40 2065 35.87 35.81 42.16 0.80 1½ x 1¼ x Y4 300 1.52 1.52 1.75 1.87 40x 40x20 2065 38.60 38 .60 44.45 0.65 11/2 x 11/2 x 1 300 1.65 1.65 1.80 1.94 40x40x25 2065 41.91 41.97 1 J. 0.88 1/2 x 1¼ x 1¼ 300 1.82 1.82 1.88 2.29 40x4032 2065 16.22 46.22 41.75 1.04 [till:] *kcj.1:I :11.111.1 I ' [etTEE Nominal Size Max. Dimensions Approx. 1x2x3 Working A Wt. Each D r PressureA M In. (mm) PSI (kPo) In. (mm) In. (mm) In. (mm) tbs. (kg) 1¼ x 1½ x 2* 300 2.16 2.16 2.02 3.28 4('X )i 1 206.6 54.864 54 d 1 cU08 2 x 1 x 2 300 2.25 2.02 2.25 3.40 50x25 0 2065 5/.1$ $1.30 5715 1.54 2 x 11/4 x 2 300 2.25 2.10 2.25 2.80 Ni _____________ )fl5 V. 1 7 7 2 x 1112 x 1/2 300 1.49 1.41 1.88 2.09 30.t40 '2 2065 31.84 35.81 41.15 ' 0.95 2 x 11/2 x Y4 300 1.60 1.52 1.97 2.40 30x4020 2063 40.64 38.60 50.03 1.09 2 x 11/2 x 300 1.73 1.65 2.02 2.54 $0x40.25 2065 4394 41.91 51.30 1.15 2 x 1¼x 11/4 300 1.90 1.82 2.10 2.85 50k40x32 2065 48.26 46.22 53.34 1.30 2 x 11/2 x 11/2 300 1.49 1.41 1.88 2.24 30x40x10 2063 31.84 35.81 41./5 1.02 2 x 1¼x2 300 2.25 2.16 2.25 3.75 50x40x50 2063 57./5 54.86 57.15 170 2 x 2 x 1/2 300 1.49 1.49 1.88 2.60 50501$ 2065 37.84 31.84 41.73 /.18 2 x 2 xY4 300 1.60 1.60 1.97 2.71 S0 k. 50x20 206.5 40.64 40.ô4 50.03 7.23 2 x 2 x 1 300 1.73 1.73 2.02 2.97 ' 43.94 5 30 2 x 2 x 1¼ 300 1.90 1.90 2.10 3.32 50x50x32 2065 48.26 4 8. 26 53,34 1.51 2 x 2 x 1112 s 300 2.02 2.02 2.16 3.72 $0x5040 2065 51 .30 57.30 54.86 1.6 9 2 x 2'x 2V2* 300 2.6 2.6 2.39 5.10 SOt5060 2065 66.04 66.04 60.706 2.31 A Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Part supplied as Bull Head Tee. fl SPF/CI-1 .15 CAST IRON THREADED FITTINGS . -. ,..' NVPL Class 125 (Standard) FIG. 3358 Straight Tee A —'-ta—A t A GUS USTED APPROVED gs/Approval Details and Limitations, ur website at www.anvilintl.com or an Anvil° Sales Representative. S FIGURE 3358 - STRAIGHT _I TEE Nominal Size MaximumDimension A Approx. Wt. Each Working Pressurea, In. (mm) PSI (kPo) In. (mm) tbs. (kg) 1 300 1.50 1.21 25 2065 38.10 055 11/4 300 1.75 1.87 32 20o5 4445 055 1½ 300 1.94 2.51 40 2065 49.27 1.14 2 300 2.25 3.96 50 2065 57,15 21/2 300 2.70 6.45 65 2065 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.cam or contact your local Anvil Representative. Dimensions: ASME B1 6.4 Class 125 Material: ASIM Al 26 Finish: Black or Hot Dip Galvanized per ASIM A153 Class A Threads: NPT per ASME B1.20.1 Agency Approvals: All cast iron threaded Fittings are UL/ULC Listed and FM Approved. PROJECT INFORMATION APPROVAL STAMP Project: 0 Approved Address: LjApproved as noted I Contractor: ri Not approved ngineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Cl-1 .15 1 I AAMMYS I I iii III 2014 Product Catalog - Sammys® for Wood . 4 Sidewinder® for Wood . 5 Sammys Swivel Head for Wood...................................................................................... 5 Sammys® for Steel............................................................................................................. 6 Sidewinder® for Steel......................................................................................................... 7 Sammys Swivel Head'" for Steel....................................................................................... 7 SammyX-PressO ............................................................................................................... 8 Sammy X-Press Sidewinder ........................... . ................. . ................... ..................... .......... 8 SammyX-Press Swivel tm'................................................................................................... 9 Sammy XPress It® Installation Tool .................................................................................. 9 Sammys® for Concrete ...................................................................................................... 10 Sidewinder® for Concrete ................................................................................. 10 Sammys Swivel Head for Concrete................................................................ 11 Concrete/Wood Installation Kit......................................................................... 11 SammysToggle .............................................................................................. 12 CeilingScrews.................................................................................................. 12 Dektite® Pipe Flashing...................................................................................... 13 SpeedyPole Tool 1M............................................................................................ 13 Approvalsand Listings ..................................................................................... 14 SpecialNotes ................................................................................................... 15 Warranty • Disclaimer of Warranty Proper fastener connection design takes in to account where and how fasteners are used. Allowance for special characteristics in materials, differences in materials, differences in types of materials being joined, unique or unusual environmental service or installation conditions and the safety factors required by anticipating normal or short term loading conditions must be considered. Due to possible differences in specifications, applications, and interpretation of results, purchasers and specifiers must make their own evaluation of the products, to determine the suitability of these products for intended use. All warranties of Buildex products, expressed or implied, including the warranties of merchantabilty and fitness for particular purposes are specifically excluded except for the following: Buildex will repair or replace any product which, within twelve months after sale by Buildex or its distributors, is found by Buildex to be defective in material or workmanship normal wear and tear accepted. This is the sole warranty of Buildex and the sole remedy available to distributor or buyer. Buildex shall not be liable for any injury, loss or damage, direct, indirect, or consequential, arising out of the use of, or the inability to use, any Buildex product. S [iiSTALLATION STEPS -iINL INTO WOOD& STEED, INSTALLATION STEPS -I J1LL INTO WOOD & STEEi Insert the appropriate nut driver into a 3/8" or 1/2" portable drill Insert the SAMMYS-' into the #14 (black) nut driver (pIn 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 318",1/2' or metric all thread rod, bolt stock. (The 1/2" requires the #I4SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximumpullout in purlin steel. Insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the #I4SW (red) nut driver (pIn 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins freely on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8' Mb, M8 or metric all thread rod or bolt stock. Note: When installing SWOR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. INSTALLATION STEPS - INTO CONCRETE: Using an SOS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). Insert the CST screw into the nut driver Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4", 318"';1/2' or metric all thread rod or boll stock. (#14SW red nut driver used with 1/2" screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the screw INSTALLATION STEPS - INTO CONCRETE: Using an SOS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammerl rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #I4SW (red) nut driver (pIn 8114910) into the opposite end. Insert the SWC screw into the nut driver Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. The SWC screw is ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener. S S LI IAN liii ii li lii ii 1HO SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installarion each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. FOR WOOD Not less than 2 nominal odth Wood Rsonng No pre-drilling required. r Quick to install using the Sammy Not less than I Nut Driver with an 18V cordless 3n0nvna1 I drill/driver. thichness (2-112) (depth or side Wood Joist I of vertical member) - Saves time from traditional Double Sheebock Ceiling • Reduces installation costs. gWih IW1s,9 I ____________________________ • Manufactured in the U.S.A. I ( - v9www.itwbuiIdex.comJ , , • i tts . f #14 Slack Nut Driver Part it 8113910 Nut )uiver 1/4 8007957 GST 100 1/4 210 (7/16' OSB) 25 125 670 (31L Ply) 1i4 8003957 GST 200 114X 2 1760 (Fir) 25 125 3/8 8007957 GST 10 1/4 x1" 210 (7I6' OSB) 300 25 125 670 (3!4 Ply) 318' 8008957 GST 20 1/4x 2 1760 (Fir) 850 1475 25 125 3/8 8068925 GST 20-SS 1/4x 2 1760 (Fir) 850 25 125 11 ai, 3/8' 8009925 GST 25-380 3/8s 2-112 2113 (Fir) 1500 25 125 3/8' 8010957 GST 30 1/4x3 2060 (Fir) 1500 1475 25 125 3181 8069925 GST 30-SS 1/4 x 3" 2060 (Fir) 25 125 1/2 8013925 GST 2 1/4 x 1760 (Fir) 25 125 1/2 8015925 GST 3 114 3 2275 (Fir) 25 125 /1$\ Ei ' (ioHS" SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. SH-GST 20 1/402' MMYS Not less than ? nominal width (1.1/2) up to 3-1/2' nipe; not less than 3 (2-1/21) nonina width 4° & 5' pipe 4 Minimum 2-1I7 from bottom for branch lines. Minimum Z from bot- tom for main tines. Exception: This requirement shall not apply to Z or thicker nailing strips resting on top of steel beams. fill No pie-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless ddll/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. Waxy a video damaassadon\ &'/ www.itwbuildex.comJ NOR T 1'4 8019957 SWG 200 1/4x2° 1725 (Fir) 25 125 318° 8020957 SWG 10 114xr 622 (Fir) 300 25 125. 38 8021957 SWG 20 1/4 n 2° 1725 (Fir) 1050 25 125 S 1 38 8073925 SWG 2O SS 114x2 1725 (Fir) 850 25 125 31,811, 8022925 SWG 25380 3/8021/2 2249 (Fir) 1500 25 125 .i4SWRed L 3.8° 8023925 . SING 30 1/4x3° 1884 (Fir) 25 125 Nut Driver Part 81149 1 (1 'May require pre-dri tiny; consi If joist manufacturer. rYIrTlr.ii ware vest 4% es MUM, w Ii emsce 0 MAX ANGLE ea Rod Part Approvals Size Number #14 Black SWIVEL MOUNT. Nut Driver -i.: 34 8139957 Parl# 8113910 1f I 12" 8303957 SH-GST/CST2.0 5/16x 1-3/4° May require pre-drrling:consalt joist manutacturu Nut Driver ri e/32/390 3/8 8269957 SH-GST/CST 20 5/16 x 1-3/4' 1903 Dim. Lumber 1500 1406 @ 45°off vertical 1350 @ 45: Dim. Lumber 903 Dim. Lumber 1406 @ 45'off vertical Dim. Lumber 25 125 25 125 Eliminates distortion of threaded rod. Accommodates up to 3 /2' x 12 pitch roof. Allows 17° deflection from vertical. Saves time from traditional methods. educes installation costs. Manufactured in the U.S.A. 1/4' 8024957 DSTR 100' 1/4-20 x 1' TEKS 3 1510 (20 ga.) 1/4' 8025957 DST 100 1/4-14x 1' TEKS 3 446 (209a.) 1/4" 8026957 DST 150 1/4-14 x 1-1/2' TEKS 3 970 (16 ga.) 1/4' 8027957 DST 200 114-14x2' TEKS 3 446 (209a.) 1/4' 8030957 TEK 500 12-24e 1-1/2' TEKS S 3125 (3/16') 3/8' 8038957 DSTR 1 * 1/4-20 x 1" TEKS 3 1510 (20 ga.) 1500 c> 3/8' 8037957 DSTR 1-1/2 12-24 x 1-1/2' TEKS 5 1510 (3/16') 1500 J. c> 3/8' 8039957 DSTR 516' 5/16-18 x 1-1/4' TEKS 3 2200 (20 ga.) 1500 318' 8040957 DST 10 1/4-14 x 1' TEKS 3 446 (20 ga.) 970 (16 ga.) 3/8' 8077925 DST 10-SS 1/4-14x 1' TEKS 3 446 (209a.) 970 (16 ga.) 3/8' 8041957 DST 15 1/4-14 x 1-1/2" TEKS 3/8' 8078925 DST 15-SS 1/4-14x 1-1/2' TEKS 3 446 (20 ga.) 970 (16 ga.) 318' 8042957 DST 20 1/4-14 x 2' TEKS 3 446 (20 ga.) 970 (l6ga.) 3/8' 8044957 DST 30 114-14),.3" TEKS 3 446 (20 ga.) 970 (16 ga.) .' 3/8" 8045957 DST 516 5/16-18x 1-1/4' TEKS 3 1500 (3/16") 1500 3/8" 8046957 TEK 50 12-24 a 1-1/2' TEKS 5 3125 (3/16') 1500 1/2' 8031925 DST 2.0 1/4-14 x 2' TEKS 3 446 (20 ga.) 970 (16 ga.) 1/2' 8033925 DSTR 1.0' 1/4-20e 1' TEKS 3 1510 (20 ga.) 1/2" 8034925 DSTR 5.16 * 5/16-18 x 1-1/4" TEKS 3 2220 (20 ga.) 1/2' 8035925 DST 5.16 5/16-18 x 1-1/4" TEKS 3 1500 (3/16") 1/2' 8036925 TEK 5.0 12-24 x 1-1/2' TEKS 5 3125 (3/16") 'Includes retaining nut i - #14 Black Nut Driver Part #8113910 1 14 SW Red Nut Driver Part 08114910 .036"-20 ga 3116" 25 125 .036.-20 ga 3/16' 25 125 .036'-20 ga 3/16 25 125 .036'-20 ga 3/16' 25 125 .188-3/16" 1/2' 25 125 1475 .036'-20ga 3/16' 25 125 1475 .060"-16 ga. 1/2" 25 125 1475 .036"-20 ga 3116' 25 125 036'-20 ga 3/16' 25 125 .036-20 ga 3/16' 25 125 .036'-20 ga 3/16" 25 125 .036'-20 ga 3/16" 25 125 .036"-20 ga 3/16 25 125 .036"-20 ga 3/16' 25 125 1475 .125-1/8' 3/16 25 125 1475 .250-1/4" 1/2' 25 125 .188-3/16" 1/4' 25 125 .036-2O ga 3/16' 25 125 .036'-20ga 3116 25 125 .125-1/8' 3/16" 25 125 .188'-3/16' 1/2" 25 125 SAMMYS® FOR STEEL Made with Teks® self-drilling fasteners - no drilling required. Installs into steel range from 20 gauge - 1/2' thicknesses. Saves time from traditional methods. Reduces installation costs. 'Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. . ............. . .......... . ....... --........................ A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. Manufactured in the U.S.A. Wa a eeodensuat'I www.itwbulldex.com) Afft SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation 71wry ~ D!!s each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete, Warranty requires the use of the appropriate nut driver for installations. Made with Tekse self-drilling fasteners - no pre-drilling required. Installs into steel range from 20 gauge- 1/2" thicknesses. fl • A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. a Woojo ootrauoe Manufactured in the U.S.A. , www.itwbuiIdex.J i 14 SW R Nut Driver Parr #8114910 114" 8047957 SAID 100 1/4-14 x r TEKS 3 1477 (16 ga.) .060-16 ga 3/16" 25 125 1/4 8049957 SWOR 100 1/4-20 x 1 TEKS 3 1900 (20 ga)1.636"-20 ga 3/16 25 125 3/8" 8050957 SAID 10 1/4-14 x 1' TEKS 3 1477 (16ga.) .060--16 ga 3/16" 25 125 3/8 8080925 SWD1OSS 1/4-14x1 TEKS3 1477 (16 ga.) .060"A 6 ga 3/16 25 125 3/8' 8052957 SAID 20 1/4-14 a 2' TEKS 3 1477 (16 g •060-16 ga 3116' 25 125 .'ci 3)8 8055957 SWDR1 1/4-20x1 TEKS 3' 1900 (2q ga 1500 1475 .036"-20 3/16 25 12 . 3/8" 8054957 SWbR 1-1/2 * 12-24 x 1-1/2" TEKS 5 2375 (3/16") 1500 1475 188-3/16" 1/2" 25 125 J"- 3/8" 8056957 SWDR 516" 5/16-18 v 1-1/4" TEKS 3 2480 (20 ga.) 1500 1475 .036-20 ga 3/16" 25 125 3/8" 8057957 SWT 15. 12-24 x 1-1/2" TEKS 5 2375 (3/16) .188-3/16" 1/2" 25 125 "Includes retaining nut S Eliminates distortion of threaded rod in sloped roof applications. 'Accommodates 3-1/2 x 12 pitch. Installs into angled z-purlin; allows threaded rod to hang plumb. Allows 17' deflection from vertical. wrl 1h • Manufactured in the U.S.A. Ward, a video demoesOalion www.itwbuiIdex.com.) #14 Black Nut Driver Part #8113910 4" 3/8' 8137957 SH-DSTR r 1/4.20X 1" TEKS 3 3220 (3116") 1500 1475 035" 3/16" 25 125 .1 id14 r1 Orange Nut Driver Pang 8273910 2368(1/2' steel Vertical) 12-24 x 1-3/4" 1306(45" off Vertical) 1500 (Vertical) TEKS 5 2281 (3/16" HSS) 850(45" off Vertical) 1585 (3/16" HSS 45" off Vertical) 2368(1/2" steel Vertical) 12-24x1.3J4 1306(45" off Vertical) TEKS 5 2281 (3/16" HSS) 1585(3/16" HSS 45" off Vertical) 'Does not comply wrth ROHS rnquirernents/ Includes retaining nut 4,, 3/16" 112" 25 125 2-1/2" 3)16" 1/2" 25 125 3/8" 8268957 SH-TEK 50 1/2" 8270957 SH-TEK 5.0 a I SA MM Y X-PRESS® Installs into Metal Deck, Purlin, or Tubular Steel The Sammy K-Press expands to provide direct vertical attachment in: - light gauge steel deck or purlin (22 ga. - 1/8"). Installs in seconds with Sammy X-Press 10 Toot, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. Manufactured in the U.S.A. Watch a video demonstradon www.itwbuildex.com) 1/4' 8181922 XP 200 Sammy X-Press 200 185 (Luminaire) 1146 (22 250 (Luminaire) .02 T .056' 3/8' 8150922 XP 20 Sammy X-Press 20 850(2W Pipe) 1146 (22 ga) 185 (Luminaire) 250 (Luminaire) .027' .027' .056' 940 (2" Pipe) .029" 1475 (4" Pipe) .104" 283 (Conduit & Cable) .029" 1500 (4" Pipe) .060" <> Sammy 3I8 8153922 XP 35 X.Press 35 185 (Luminaire) 1783 (16 > 250 )Luminaire) .029' .056" 940 (2' Pipe) .029 1475 (4" Pipe) .104" 416 (Conduit & Cable) .059" 125" 25 125 Metal Deck 125" 25 125 Metal Deck 125' 25 125 Purl/n Pie-Pour Structural Concrete@ 3000 psi Metal Deck 3/8" 8150922 XP 20 Sammy 1146 (22 ga) 850 (2Vr Pipe) 25 125 Metal Deck - resS 20 Post-Pour Range II LWC5 35 PCF (I) Post-Pour) Pre-Pour Structural Concrete @3000 psi Post-Pour Range tt LWC5 35 PCF (tbsl tt) 1 • The Sammy K-Press Sidewinder expands to t provide horizontal attachment in: - 16 ga - 3/16" steel - purl/n, tubular steel. Installs in seconds with Sammy X-Press P Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited: ie. metal roof (SWXP) j deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. Manufactured in the U.S.A. Watch a v,deodemansfrarjan www.itwbuildex.comj 3/8" 8293957 SWXP 35 1798 (16 ga) 80 (Luminaire) .059" X-Press 35 416 )Conduit& Cable) oHS V (r,"D eLcac1oniD U .125" 25 125 Purl/n The Sammy X-Press Swivel allows you to hang plumb in extreme roof pitches: - 89' in z-purlin - 45' in metal deck for 12/12 pitch OR mn • wiE saving Installs in seconds with Sammy X-Press Its Tool, time & installation costs. OR Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof Roof flçS deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. Manufactured in the U.S.A. - Warch a odomoasO8(on '\ www.itwbuildex.coiJ 750(2' Pipe) 170 Vertical (Luminaire) 318' 8294922 SXP 20 - Swivel 11)1 80 (0) 45 (Luminaire) .029' 635 (2' Pipe) .029' .125' 25 125 Metal Deck X-Press 20 B (45' Oil Vert) 283 Vertical (Conduit Cable) 233 @ 45' (Conduit & Cable) 1250 (3-1/2' Pipe) 250 Vertical (Luminaire) ?' 30 8295922 SXP 35 x-'35 1558 Oft Veil) 500 Vertical (Conduit& Cable) 059' 029' .125' 25 125 Purlin 635 (2' Pipe) . 333 @ 89' (Conduit & Cable) r L 1/2' 8272957 SXP 2.0 Swivel 1061 (22ga Veil) 027 125' 25 125 Metal Deck X.Press 2.0 829 (45 Oft Veil) Swivel 1675(16ga Veil) 1/2 827195- SXP 3.5 X-Press 35 1558 (89' Off Veil) .060' .125' 25 125 Purlin 1#-7li'ii Product Features / • . • The Sammy X-Press expands to provide direct vertical attachment in: metal deck (22-16 gauge) z-pudin (18-16 gauge) \ oi l ,. ¶ I •Manufactured n the U.SA t ii 8194910 UXPIT' Universal X-PressltTool 8152910 XPDB 25/64 0(01 Bit 'Tool Includes: Sleeve, Bit Receiver, Hex Wrench, and 25164 Drill Bit S SAMMYS® FOR CONCRETE ISA 01 MMY :fl Appllcafi Easy two step process (Drill hole & drive Sammys concrete anchor). %" pre-drilled pilot hole required. Concrete Installation Tool available for a one tool installation process. Manufactured in the U.S.A. Ntrw Sammvs for Cracked Concrete now available! .0 57 Ljrt'o i7 10, -U Oc ',c'iLp2s. :,flD c 4 D It fl et www.itwbuildex.c0J . :Approvals Rod Size Oart Model Number . L Ultimate I'M Test Box Case VERTICAL MOUNT #14 Black 114' 8058957 CST 200 5/16 x 1-3/4' 2400 25 125 '- 3/8" 8059957 CST 20 5/16 x 1-3/4' 2400 '1475 25 125 Parl# io . e14swiert 3/8' 8145925 CST 20-SS 5/16x 1.3/4' 2400 25 125 Nut Driver i: 1/2' 8060925 CST 5/16x 1-3/4' 2400 25 125 Part 6114910 E ICC-ESR 2202 3/8 8306957 CCST 516 5/16-14 x 2-1/2' 857" 25 125 For complete performance data see ICC Report ESR-2202 Tested in 3000 P51 concrete " Pullout strength for Cracked Concrete and Seismic Zones A-F Easy two step process (Drill hole & drive Sammys concrete anchor). al / pre-drilled pilot hole required. u Concrete Installation Tool available for a one tool *r installation process. Manufactured in the U.S.A. cQ C 'Now Sarnmys for Cracked Concrete now a-datable! Watch a uideodemo0s5e110u Approvals Rod Part Model Screw Ultimate FM Test Box Case Siz bI7 www.itwbuildex.comJ ----. Number Descriptions HORIZONTAL MOUNT -[ 1/4' 8062957 SWC 200 5/16x 1-3/4' 2450 25 125 3/8' 8061957 SWC 20 5/16 x 1.3/4" 2450 1475 - 25 - 125 WRc-:j 3/8' 8307957 SW-CCST516 5/16-14x2-1/2 857" 25 125 Nut Driver Part C a 114910. 'Tested in 3000 PSI concrete "Pullout strength for cracked concrete and Seismic Zones A-F \ I (Fan). i/ SPECIAL NUT DRIVE SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation oHS each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. FROM MM VS° Installs vertically and swivels up to 89° in wood & concrete structures. Eliminates distortion of threaded rod. 1/4" pre-drilled pilot hole required. Concrete installation tool available for a one piece installation process. Manufactured in the U.S.A. New Sammys for Cracked Concrete now available! - SWIVEL MOUNT 3/8' 8269957 SH-GST/CST 20 5116 n 1-3/4' W 8303957 SH-GST/CST 2.0 5116 x 1-3/4' - 318 8308957 SH-CCST 516 5/16-14 x 2-1/2' Wale: UL Listed for wood - see page 5 2537 in 3000 psi concrete 1459 @ 45°oft vertical in 3000 psi concrete 2852 in 6000 psi concrete 25 125 1636 @ 45°otf vertical in 6000 psi concrete 2537 in 3000 psi concrete 1459 @ 45°off vertical in 3000 psi concrete 2852 in 6000 psi concrete 25 125 1636 @ 45°off vertical in 6000 psi concrete 857" 25 125 Tested in 3000 PSI concrete "Pullout strength for cracked concrete and Seismic Zones A-F (b) (b) (o) (d) (h) (e) (h) ..2!luIuI•.4tMIP () (c) a) Part Number Description Each1IPT 8122910 Concrete Installation Kit (a) Kit includes the following items: 8113910 #14 Black Nut Driver (b) 1 8114910 #14SW Red Nut Driver (c) 1 8116910 #25O Bit (1/4")(d) 1 8117910 SDS Bit (1/4') (e) 1 8118910 7/32 Wood Bit (f) 1 8120910 HEX 250 Bit Receiver (1/4") (g) 1 8098910 SL25O Sleeve (h) 1 8121910 SOS 6250 Bit Receiver (1/4")' "Only sold separately- not included in kit. I A CCESSORIES Pre-Cast Hollow Core , ------. -,"""- Concrete Pre-drill a 5/8" hole with a regular drill or hole saw. Insert SST screw into #14 black nut driver. With wing nut and washer on bolt, insert wing nut through surface, and begin installation. When bolt is secure and nut driver spins free, stop drill motor and remove. SST screw is now ready to receive 1/4", 3/8", or Metric all thread rod or bolt stock. il #14 Black Nut Driver Part #8113910 1/4" 8063925 SST 300 114 x 3 450 (Lath & Plaster) 25 404 (2 Layers 5/8 Rock( 3/8" 8064925 SST 30 1/4n3" 450 (Lath & Plaster) 404 (2 Layers 5/8 Rock) 25 125 125 3/16" eyelet to accommodate common wire size. ICC approvals can be found at www.itwbuildex.com under Evaluation Report # ER-5367. k CWIT Installation Tool Part #8110910 ICC STEEL 8107957 CWSD 1" Teks 1/4 xl" 2' 472 (20 ga( 16 ga. 170 (20 ga.) 25 125 ICC STEEL 8190957 CWSD 15 Gimlet 1/4 x 1.1/2' 2-3/4" 472 (20 ga( 209a. 270 (20 ga.) 25 125 WOOD 980 (Fir) ICC STEEL 8108957 CWSD 2* Teks 1/4x2" 3-1/4" 472 (209a) 16 ga. 170 (209a.) 25 125 ICC 8110910 CWIT Installation Tool * Does not comply with R011S rujirements I NOW COMES FULLY ASSEMBLED u — Complies with NFPA 13 Code Changes. I4—OEKflTE STAY UP TO CODE! - with a qurcer. CLEANCE no,c ft CitOt HO RA LE vay to ilO your F rhcrcticfrzr urt. INSUlATED FREEZER STRUCTURE - Flashing for dry pendant sprinklers subject to extreme temperature changes. One piece construction is easy to install. Pipe diameter markings ensure accurate fit. EPDM temperature range of -65°F to +250°F. -4— DRY SPRINKLER 4001910 Mini 1/4" - 1-1/8" 3-1/2" 1-3/4" 20 4003910 1 114'- 2" 4-3/4" 3" 10 4004910 2 1-3/4 - 3-1/4" 6-1/4 4" 10 "Speed your labor by 25% > - I Work from the ground up No scaffolding, ladders, or lifts I I • Perfect for working in tight spaces, through ceiling grid, —I LJ nnd hint vniiltM nnilincis I Part Number Description 80X Qty I !1YL1 8007957 GST 10 3/8° Vertical CPVC 1-1/2" 300 1-1/2" 8020957 SWG 10 3/8' Horizontal CPVC 1-1/2 300 1.1/2 8008957 GST 20 3/8' Vertical 2-1/2" 850 1-1/2" 4" 1475 - 1-1/2" 8068925 GST 20-55 3/8" Vertical 2-1/2" 850 1-1/2" 8010957 GST 30 3/8" Vertical 4" 1500 1-1/2" 4" 1475 1-1/2" 8009925 GST 25-380 3/8" Vertical 4" 1500 1-1/2" 8022925 SWG 25-380 3/8' Horizontal 3-1/2' - 4" 1500 1-1/2" 8021957 SWG 20 318" Horizontal 2-1/2"- 3""" 1050 1-1/2" 8073925 SWG 20-SS 3/8" Horizontal 2-1/2" 850 1-1/2" 8269957 SH-GST!CST 20 3/8" 45" Angle off Vertical 2-1/2' 850 11/2" 8269957 SH-GST/CST 20 3/8' 45° Angle off Vertical 4" 1500 1-1/2" 8139957 SH-GST2O 3/8" 17° Angle off Vertical 1050 1-112" 4" 1475 1-1/2" r 8038957 DSTR 1 3/8' Vertical 4" 1500 .035" 4" 1475 .105' 8037957 DSTR 1-1/2 3/8" Vertical 4" 1500 .035" 4' 1475 .105" 8039957 DSTR 516 3/8' Vertical 4" 1500 .037" 4" 1475 .105" 8045957 DST 516 3/8" Vertical - 4" 1500 .188" 4" 1475 .188" 8046957 TEK 50 3/0" Vertical 4" 1500 .250" 4" 1475 .188" 8055957 SWDR 1 3/8' Horizontal 4" 1500 .037' 4" 1475 .060" 8056957 SWDR 516 318' Horizontal 1500 .037" 4" 1475 .060" 8054957 SWDR 1-1,2 IF Horizontal 4' 1500 .037" 4" 1475 .060" 8137957 SH-DSTR 1 3/8" 17° Angle off Vertical 4' 1500 .03.5" 4' 1475 .105" 8268957 SH-TEKSO 3/8' Vertical 2-1/2" 850 70 Angle off Vertical 4 1500 8150922 XP 20 3/8" Vertical 2-1/2' 850 .027" 8153922 XP 35 3/8' Vertical 4" 1500 .060" 8294922 SXP 20 3/8" Vertical or up to 45' 2" 750 .027" 2' 635 .029" 8295922 SXP 35 3/0" Vertical or up to 89" 3.1/2" 1250 .060" 2" 635 .029° 8293957 SWXP35 36 Horizontal 3-1/2' 1250 .060" SAMMYS FOR CONCRETE PIPE HANGER 8059957 CST 20 3/8" Vertical 4° 1475 3000 8061957 SWC 20 318' Horizontal 4 1475 3000 8150922 XP 20 3/5" Vertical 2-1/2" 850 Pre-Pour Structural @ 3000psi 8150922 XP 20 3/8' Vertical 2-1/2" 850 Post-Pour Range It LWC 5 35 PCF (lbs/fl3) 185 .027" 8150922 XP 20 3/0" Vertical 250 .035" 185 .027" 8153922 XP 35 3/8' Vertical . 250 .035" 185 .027" 8181922 XP 200 1/4' Vertical 250 .035" Vertical 170 .027° 8294922 SXP 20 3/8 45° 80 .027" Vertical 250 .060° 8295922 SXP 35 3/8" 90° 80 .060" 8293957 SWXP35 3/8' Horizontal 80 .060" 8150922 XP 20 3/8" Vertical 283 .027" Max 4 trade size EMI, RMC, and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 3/8" Vertical 283 .027° Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8293957 SWXP35 3/8' Horizontal 500 .060° Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit UL Listed 4S16 - Cable Hanger, Cat. No. C-Z2000 Plenum Rated, 8149957 CZ2000 1/4" or 3/8" Onto Vertical Rod Complies w/ NEC Standards Sheet TSteel 1Gauges Gauge No. 22 ga. 20 ga. 18 ga. 16 ga. 14 ga. 12 ga. 118" 3116" 1/4" Nominal Decimal Equivalent .030" .036' .048" .060" .075" .105" .125" .188° .250" "SWG 25-380 Maximum pipe size in composite mood joist allowed by UL in 3-1/2° UL compliance with NEC Standards. SWG 25-380 Maximum pipe nice in wood timber or tout allowed by UL is 4" UL and FM tests were performed in compliance with NEPA 13 Standards. ..SWG 20 Maximum pipe size in composite wood joist allowed by UL in 2-1/2" Fastening requirement: 5 times weight of water-filled schedule 40 pipe plus 250 pounds. SPECIAL NOTES Engineering Note isIn 1996, the anchors listed by UL were tested in plate steel that measured .188" and .118". Subsequent testing was done for z-purlin applications in May 1997 using (.037") or 20 gauge steel. Most recently in 2008, testing with the new Sammy XPressx was completed using (.030") or 22 gauge steel metal deck. Sammye Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offerring. Vibratory EnvironmentsV' For attaching or anchoring in high vib?atory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8" smaller than root diameter of fastener. Model" Root Diameter Hole Size GST 20 .182' 1/8" GST 25-380 .280" 7/32" SWG 20 .182" 1/8" SWG 25-380 .280" 7/32" To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pie-drilling. NFPA/NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Raving Jurisdiction to confirm application and usage. UL Listings / FM Approvals UL and FM reports are available at www.itwbuildex.com A- 111100 AS 005000 000 CABLE BA IOWA PC 0000 11510010 0001101 FOR 1011150010 Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Manufactured in the U.S.A. Products Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 Consult the table below: 0 C 1? 4 1 SI. 1111111! 41111111 SAMMYS itwbuildex corn National Headquarters Customer Service 700 High Grove Blvd. 1765 Holmes Rd. Glendale Heights. 11-60139 Elgin, II 60123 P: 630.825.7900 P: 800.846.5611 I B: ordersOitwooa corn Technical Support P 800.848.5611 E: techrcaJ@itwccna.corn Made In U.S.A. Sinvu II. $.wrIc . S,wr.P,r3 $w.. X.R S4'd. 5nwry c*eø Pci. TOO.epo$-f. * Lre. Si HQd, Sys Tao. bw T4k - - - - sac. Ytwk& lI). 0eI,t * raq4tprW lr nal. of 003 W"r.0 Pty U1 5 0 24 timm To I 4 4 4 4 4 444 *Fig. 25 - Surge Restrainer C® us LISTED Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 F9 ( .1 I; .7 l All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 61 Pipe Hangers & Supports B-Line by ['N Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line B317ONF) Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining for Copper Tubing (B-Line B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line B317ONFC) Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe @TOLCO c &us Material: Steel, Pre-Galvanized to G90 specifications LISTED Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in B hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) A - in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" (20mm) thru 8" (200mm)). '. Conforms to Federal Specifications WW-H-1 71 E & A-A-1l 92A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Fig. 200-1/2 to 200-2 -- Fig. 200-21/2 10200-8 Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Part number and pipe size , 4, ** Note: For metric hanger rod sizes add the , metric rod size to the figure number. Example: 200M8-11/2 or 200M10-11/2 Fig. 200 Fig. 200C Fig. 200F Part No. 200_1/2 Pipe 1/2 ' Size (15) !T /8"-16 Iij'.: M8 or M10 A 1. 31/8" (79.4) 2/8" 8 (66.7) Max.Load E1 1• . 400 (1.78) i ix'/I ii 11 IT, (5.0) 200-I4 3/4" (20) /8"-16 M8 or M10 31/8" (79.4) 21/2" (63.5) 400 (1.78) 11 . (5.0) 200-1 1" (25) /8"-16 M8 or MiD 3/8" (85.7) 2/8" (66.7) 400 (1.78) 12 (5.5) 200-11/4 11/4" (32) /8"-16 M8 or M10 33/4" (94.0) 2/8" (73.0) 400 (1.78) 13 (59) 200_11/2 ' /8'-16 M8 or MiD 37/8" (98.4) 2/8" (73.0) 400 (1.78) 14 (6.4) 200-2 2' (50) /8"-16 M8 or MiD 41/2" (114.3) 3" (76.3) 400 (1.78) 15 (6.9) 200_2112 21/2" (65) /8"-16 M10 55/8" (142.9) 41/8" (104.7) 600 (2.67) 27 (12.3) 200-3 3" (75) /8"-16 MiD 5 /8" (149.1) 4" (101.6) 600 (2.67) 29 (13.3) 200_31/2 31/2 (90) /8"-16 MiD 7 /8" (187.3) 51/4" (133.3) 600 (2.67) 34 (15.6) 200-4 4" (100) /8"-16 MiD 73/8" (187.3) 5" (127.0) 1000 (4.45) 35 (16.0) 200-5 5" (5) 1/2"13 M12 91/8" (231.8) 61/4" (158.7) 1250 (5.56) 66 (30.2) 200-6 6" (150) 1/2"13 M12 101/8" (257.2) 6/4" (171.4) 1250 (5.56) 73 (33.4) 200-8 8" (200) 1/2"13 M12 131/8" (333.4) 8/4" (222.2) 1250 (5.56) 136 (62.3)