Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3981 JAMES DR; ; FPR2017-0394; Permit
Qty of PERMIT REPORT Carlsbad Print Date: 10/21/2021 Permit No: FPR2017-0394, Status: Closed - Finaled Single Family Fire Sprinkl Applied: 11/21/2017 Issued: 12/01/2017 DEV05075 Finaled Close Out: 09/15/2021 Job Address: 3981 JAMES DR, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Residential Work Class: Parcel if: 2071307700 Track if: Valuation: $578,296.43 Lot #: Occupancy Group: Project if: #01 Dwelling Units: Plan if: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check if: Plan Check if: Inspector: Final Inspection: Project Title: HIGHLAND JAMES Description: HIGHLAND JAMES SUBDIVISION (LOT 3) -SPRINKLER 13D (42 HEADS) FPContractor: INNOVATIVE FIRE PROTECTION INC 8779 COTTONWOOD AVE, if STE 101 SANTEE, CA 92071-4457 (619) 593-8200 FEE AMOUNT FIRE NFPA 13D Single Family System (lnsp/Bldg) S $121.00 FIRE NFPA 13D Single Family System (Plan Review) $239.00 FIRE Reinspection (per inspection) $187.00 Total Fees: $547.00 Total Payments To Date: $547.00 -- Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov HYDRAULIC CALCULATIONS for Job Information Project Name: HIGHLAND JAMES SUBDIVISION (LOT3) Contract No.: C6864 City: CARLSBAD, CA 92008 Project Location: 3981 JAMES DR. Date: 11/17/2017 Contractor Information Name of Contractor: INNOVATIVE FIRE PROTECTION, INC. Address: 8779 COTTONWOOD AVE.,STE. 101 City: SANTEE, CA 92071 Phone Number: 619-593-8200 E-mail: DAV1N@IFPINC.NET Name of Designer: DAVJN BROOKS Authority Having Jurisdiction: CARLSBAD FIRE AUTHORITY Design Remote Area Name Remote Area Location LAUNDRY Occupancy Classification RESIDENTIAL Density (gpm/ft2) 0.053 Area of Application (ft2) 400 Coverage per Sprinkler (ft2) 400 Number of Calculated Sprinklers 1 In-Rack Demand (gpm) 0 Special Heads Hose Streams (gpm) 5 Total Water Required (incl. Hose Streams) (gpm) 26 Required Pressure at Source (psi) 65.8 Type of System Wet Volume -EntireSystem (gal) 17.6 gal Water Supply Information Date 11/15/2017 Location CITY OF CARLSBAD Source 1 Notes File: Y:ENGlNEERING\3A.Project Files\C6864 HIGHLAND JAMES SUBDIVESlON\LOT3C----_recover.dwg Date 11/17/2017 Copyright© 2002-2012 Tyco Fire Protection Products Page 1 Job: HIGHLAND JAMES SUBDIVISION (L013) Node Labels: Off Pipe Labels: Off Date 11/17/2017 Diagram for Design Area: I lflntimi7erl HvdriiiIir SimnlifiAcfl ---.--..-. ..-- 4A ----- ... .-..----.- File: Y:\ENGINEERING\3A.Project Files\C6864 HIGHLAND JAMES SUBDIVESION\LOT 3\C---_recover.dwg Copyright© 2002-2012 Tyco Fire Protection Products Page 2 Job: HIGHLAND JAMES SUBDIVISION (LO13) Hydraulic Analysis for: I Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft3) Fluid Dynamic Viscosity, (Ib•s/ft2) Water Supply Parameters Supply 1:1 Supply Analysis Demand Hazen-Williams Water @ 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Flow cirm I Pressure (psi) 0 h I 76.4 500 I 67.4 Node at Source Static Pressure I I Residual Pressure I I Flow I I Available I i Pressure I Total Demand I I I Required Pressure I (psi) I (psi) (gpm) I I I (psi) (gpm) I I (psi) I 1 76.4 67.4 500 J 76.3 26 65.8 Hoses Inside Hose Flow/ Standpipe Demand (gpm) 5 Outside Hose Flow (gpm) 0 Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) 0 Total Hose Flow (gpm) 5 Sprinklers Ovehead Sprinkler Flow (gpm) 21 InRack Sprinkler Flow (gpm) 0 Other (custom defined) Sprinkler Flow (gpm) 0 Total Sprinkler Flow (gpm) 21 Other Required Margin of Safety (psi) 0 - Pressure (psi) 65.8 1 - Flow (gpm) 26 Demand w/o System Pump(s) N/A File: Y:\ENGINEERING\3A.Project Files\C6864 HIGHLAND JAMES SUBDIVESION\LOT3\C----_recover.dwg Date 11/17/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 3 U) >1 S C.) = S >1 = - ed 0 Job: HIGHLAND JAMES SUBDIVISION (LOT3) Hydraulic Analysis for: I Graph Labels Label Description Values Flow (gpm) Pressure (psi) Si Supply point #1 -Static 0 76.4 S2 Supply point #2-Residual 500 67.4 Dl Elevation Pressure 0 10 D2 I System Demand 26 65.8 Curve Intersections & Safety Margins Curve Name Intersection Safety Margin Pressure (psi) Flow (gpm) Pressure (psi) @ Flow (gpm) Supply 76.3 1 28.6 10.5 26 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psil/z) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) Al Overhead Sprinkler 400 4.9 0.05 20 18.4 0.053 21 18.4 File: Y:\ENGINEERING\3A.Project Files\C6864 HIGHLAND JAMES SUBDIVESION\LOT 3\C----_recover.dwg Date 11/17/2017 Copyright ©20022O12Tyco Fire Protection Products Page 5 Job: HIGHLAND JAMES SUBDIVISION (LOT3) Hydraulic Calculations / Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge m/ s1½ gp p gpm ft2 psi psi ft gpm gpm/ft2 psi gpm Al Overhead Sprinkler 4.9 21 400 18.4 18.4 20 HEAD Open 1 0.053 -10 20 066 Node 23.6 21 NODE -10.4 052 Node 27.6 21 NODE -10.4 058 Node 28 21 NODE -10.4 020 Node 33.5 11 NODE -6.1 012-0 Node 39.5 5.5 NODE -3.7 012-I Node 43.9 5 NODE -3.5 011 Node 46.5 0 NODE -1.3 003 Node 48.6 -3 NODE 0 GPM1 Inside Hose 49.5 -3 HOSE 5 0 5 001 Node 49.6 -3 NODE 0 009-0 Node 49.6 -3 NODE 0 009-I Node 55.4 -3 NODE 0 010-0 Node 55.9 -3 NODE 0 010-I Node 59.9 -3 NODE 0 1 Supply -26 65.8 -3 SUPPLY 0 File: Y:ENGlNEERlNG\3A.Project Files\C6864 HIGHLAND JAMES SUBDIVESION\LOT 3\C---_recover.dwg Date 11/17/2017 Copyright©2002-2O12Tyco Fire Protection Products Page 6 Job: HIGHLAND JAMES SUBDIVISION (LOT3) Hydraulic Calculations! Fluid Delivery Time Analysis Pipe Data Path # Type Schedule I-IWC Fittings Length Flow Fr.Resist. Vel.Pres. Start Pipe Ref. Hgroup Size Rough. Eq.Len. Total Len. Velocity Loss Frict. Loss Elev. End ft gpm psi/ft psi in ft ft ft/s psi psi 1 Brline CPVC 150 2(BM.Tee-Run);1(BM.Tee-Br);2(BM 11.76 21 0.2287 0.9 066 082 PIPE .75 0.000084 .90), 1 13 24.76 11.24 5.7 -0.4 Al 1 Brline CPVC 150 5(BM.Tee-Run);2(BM.Tee-Br); 38.73 12.6 0.0881 0.3 058 060 PIPE .75 0.000084 11 49.73 6.71 4.4 0 066 1 Brline CPVC 150 l(BM.Tee-Br);2(BM.90); 12.88 15.7 0.0431 0.2 020 095 PIPE 1 0.000084 15 27.88 5.28 1.2 4.3 058 1 Cmain CPVC 150 1(coupling);3(BM.90);1(13M.Tee-Ru 24.5 21 0.0743 0.3 012-0 014 PIPE 1 0.000084 n);1(BM.Tee-Br); 47.41 7.08 3.5 2.4 020 22.91 1 VALVE RESI RISER 0 0.5 21 8.3904 0 012-I 158 VALVE 1 0 0 4.2 0.2 012-0 1 Cmain CPVC 150 1(coupling); 5 21 0.0743 0.3 011 013 PIPE 1 0.000084 1.91 6.91 7.08 0.5 2.2 012-1 1 Cmain Copper L 150 1(coupling);1(us.90); 3.51 21 0.1053 0.4 003 011 PIPE 1 0.000084 4.05 7.55 8.17 0.8 1.3 011 1 Cmain PVC150 150 1(us.Tee-Run);4(BM.45);1(BM.90); 63.28 21 0.0117 0.1 001 005 PIPE 1.5 0.000084 16 79.28 3.31 0.9 0 003 1 Cmain PVC150 150 1(coupling); 0.4 26 0.0173 0.1 009-0 002 PIPE 1.5 0.000084 1.51 1.91 4.1 0.0 0 001 1 BFP WILKINS950XL 0 0.79 26 7.3765 0 009-I 157 BFP 1 0 0 5.8 0 009-0 1 Cmain Copper K 150 1(coupling); 1.5 26 0.1806 0.8 010-0 003 PIPE 1 0.000084 1.17 2.67 10.74 0.5 0 009-1 1 VALVE METER 0 05 26 8 0 010-I 156 VALVE 1 0 0 4 0 010-0 1 Cmain Copper K 150 32.76 26 0.1806 0.8 1 004 PIPE 1 0.000084 10.74 5.9 0 010-1 2 Cmain Copper K 150 1(us.Tee-Br); 0.5 5 0.0085 0.0 001 001 PIPE 1 0.000084 5.84 6.34 2.06 0.1 0 GPM1 3 Brline CPVC 150 8(BM.Tee-Run);4(BM.90); 69.72 8.5 0.0424 0.1 052 078 PIPE .75 0.000084 24 93.72 4.53 4 0 066 3 Brline CPVC 150 9(BM.Tee-Run);3(BM.Tee-Br);2(BM 62.43 5.4 0.0181 0.1 020 022 PIPE .75 0.000084 .90); 88.43 2.86 1.6 4.3 052 26 4 Brline CPVC 150 1(BM .Tee-Br);4(BM.Tee-Run); 1(BM 49.37 3.1 0.0067 0.0 058 059 PIPE .75 0.000084 .90); 60.37 1.67 0.4 0 052 11 File: Y:\ENGINEERING\3A. Project Files\C6864 HIGHLAND JAMES SUBDIVESION\LOT3\C---_recover.dwg Date 11/17/2017 Copyright© 2002-2012 Tyco Fire Protection Products Page 7 Job: HIGHLAND JAMES SUBDIVISION (L013) Hydraulic Calculations / Fluid Delivery Time Analysis Pipe Data Start Disch. Start Tot. Pres. End Disch. End Tot.Pres. gpm psi gpm psi 23.6 21 18.4 28 23.6 33.5 28 39.5 33.5 43.9 39.5 46.5 43.9 48.6 46.5 49.6 48.6 49.6 49.6 55.4 49.6 55.9 55.4 59.9 55.9 26 65.8 59.9 49.6 5 49.5 27.6 23.6 33.5 27.6 28 27.6 File: Y:ENGlNEERlNG\3A.Project Files\C6864 HIGHLAND JAMES SUBDIVESION\LOT 3\C---_recover.dwg Date 11/17/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 8 Job name: HIGHLAND JAMES SUBDMSION (LO13) Sheet number: PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added(q)* Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES I frict (Pf) (ft) (9pm/psi'/2) (gpm) (in) (ft) (ft) (psi) (psi) Al 20 4.9 21 .75 2x(BM.Tee-Run)=2 11.76 150 18.4 066 21 21 0.874 lx(BM.Tee-Br)=3 13 0.2287 -0.4 2x(BM.90)=8 24.76 5.7 066 21 -8.5 .75 5x(BM.Tee-Run)=5 38.73 150 23.6 058 21 12.6 0.874 2x(BM.Tee-Br)=6 11 0.0881 0 49.73 4.4 058 21 3.1 1 lx(BM.Tee-Br)=5 12.88 150 28 020 11 15.7 1.101 2x(BM.90)=10 15 0.0431 4.3 27.88 1.2 020 11 5.4 1 lx(coupling)=1.91 24.5 150 33.5 012-0 5.5 21 1.101 3x(BM.90)=15 22.91 0.0743 2.4 lx(BM.Tee-Run)=l 47.41 3.5 lx(BM.Tee-Br)=5 012-0 5.5 0 1 0.5 0 39.5 RESI RISER 012-1 5 21 0 0 8.3904 0.2 *** 0.5 4.2 012-I 5 0 1 lx(coupling)=1.91 5 150 43.9 011 0 21 1.101 1.91 0.0743 2.2 6.91 0.5 011 0 0 1 lx(coupling)=1.35 3.51 150 46.5 003 -3 21 1.025 lx(us.90)=2.7 4.05 0.1053 1.3 7.55 0.8 003 -3 0 1.5 4x(BM.45)=8 63.28 150 48.6 001 -3 21 1.61 lx(BM.90)=8 16 0.0117 0 79.28 0.9 001 -3 5 1.5 lx(coupling)=1.51 0.4 150 49.6 009-0 -3 26 1.61 1.51 0.0173 0 P 1.91 0.0 009-0 -3 0 1 0.79 0 49.6 WILKINS95OX 009-1 -3 26 0 0 7.3765 0 L 0.79 5.8 *** 009-I -3 0 1 lx(coupling)=1.17 1.5 150 55.4 010-0 -3 26 0.995 1.17 0.1806 0 2.67 0.5 010-0 -3 0 1 0.5 0 55.9 METER 2 010-I -3 26 0 0 8 0 *** 0.5 4 010-1 -3 0 1 32.76 150 59.9 1 -3 26 0.995 0 0.1806 0 32.76 5.9 GPM1 -3 5 1 lx(us.Tee-Br)=5.84 0.5 150 49.5 001 -3 5 0.995 5.84 0.0085 0 6.34 0.1 066 21 0 .75 8x(BM.Tee-Run)=8 69.72 150 23.6 052 21 8.5 0.874 4x(BM.90)=16 24 0.0424 0 93.72 4 052 21 -3.1 .75 9x(BM.Tee-Run)=9 62.43 150 27.6 020 11 5.4 0.874 3x(BM.Tee-Br)=9 26 0.0181 4.3 2x(BM.90)=8 88.43 1.6 052 21 0 .75 lx(BM.Tee-Br)=3 49.37 150 27.6 058 21 3.1 0.874 4x(BM.Tee-Run)=4 11 0.0067 0 lx(BM.90)=4 60.37 0.4 © 2006 National Fire Protection Association Page 9 Job name: HIGHLAND JAMES SUBDIVISION (LOT3) Sheet number: PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added(q)* Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES I frict (Pf) (ft) (gpm/psi'/z) Wpm) (In) (if) (if) (psi) (psi) * Discharge shown for flowing nodes only © 2006 National Fire Protection Association Page 10 Job: HIGHLAND JAMES SUBDIVISION (L013) Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psll/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: I Al 20 4.9 21 .75 2x(BM.Tee-Run)=2 11.76 150 18.4 066 21 21 0.874 lx(BM.Tee-Br)=3 13 0.2287 -0.4 2x(BM.90)=8 24.76 5.7 066 21 -8.5 .75 5x(BM.Tee-Run)=5 38.73 150 23.6 058 21 12.6 0.874 2x(BM.Tee-Br)=6 11 0.0881 0 49.73 4.4 058 21 3.1 1 lx(BM.Tee-Br)=5 12.88 150 28 020 11 15.7 1.101 2x(BM.90)=10 15 0.0431 4.3 27.88 1.2 020 11 5.4 1 lx(coupling)=1.91 24.5 150 33.5 012-0 5.5 21 1.101 3x(BM.90)=15 22.91 0.0743 2.4 lx(BM.Tee-Run)=1 47.41 3.5 lx(BM.Tee-Br)=5 012-0 5.5 0 1 0.5 0 39.5 RESI RISER 012-1 5 21 0 0 8.3904 0.2 *** 0.5 4.2 012-I 5 0 1 lx(coupling)=1.91 5 150 43.9 011 0 21 1.101 1.91 0.0743 2.2 6.91 0.5 011 0 0 1 lx(coupling)=1.35 3.51 150 46.5 003 -3 21 1.025 lx(us.90)=2.7 4.05 0.1053 1.3 7.55 0.8 003 -3 0 1.5 4x(BM.45)=8 63.28 150 48.6 001 -3 21 1.61 lx(BM.90)=8 16 0.0117 0 79.28 0.9 001 -3 5 1.5 lx(coupling)=1.51 0.4 150 49.6 009-0 -3 26 1.61 1.51 0.0173 0 1.91 0.0 009-0 -3 0 1 0.79 0 49.6 WILKINS95OX 009-1 -3 26 0 0 7.3765 0 L 0.79 5.8 *** 009-I -3 0 1 lx(coupling)=1.17 1.5 150 55.4 010-0 -3 26 0.995 1.17 0.1806 0 2.67 0.5 010-0 -3 0 1 0.5 0 55.9 METER 2 010-I -3 26 0 0 8 0 *** 0.5 4 010-1 -3 0 1 32.76 150 59.9 1 -3 26 0.995 0 0.1806 0 32.76 5.9 1 65.8 Path No: 2 GPM1 -3 5 1 lx(us.Tee-Br)=5.84 0.5 150 49.5 001 -3 5 0.995 5.84 0.0085 0 6.34 0.1 001 49.6 File: Y:\ENGINEERING\3A.Project Files\C6864 HIGHLAND JAMES SUBDIVESION\LOT 3\C----_recover.dwg Date 11/17/2017 Copyright© 2002-2012 Tyco Fire Protection Products Page 11 Job: HIGHLAND JAMES SUBDIVISION (L013) Hydraulic Calculations PIPE INFORMATION Path No: 3 066 21 0 .75 8x(BM.Tee-Run)=8 69.72 150 23.6 052 21 8.5 0.874 4x(BM.90)=16 24 0.0424 0 93.72 4 052 21 -3.1 .75 9x(BM.Tee-Run)=9 62.43 150 27.6 020 11 5.4 0.874 3x(BM.Tee-Br)=9 26 0.0181 4.3 2x(BM.90)=8 1 88.431 1.6 020 33.5 Path No: 4 052 21 T .75 lx(BM.Tee-Br)=3 49.37 150 27.6 058 21 3.1 0.874 4x(BM.Tee-Run)=4 11 0.0067 0 lx(BM.90)=4 60.37 0.4 058 28 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 11.24 ft/s occurs in the following pipe(s): (066-Al) " Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File: Y:ENGINEERING\3A.Project Files\C6864 HIGHLAND JAMES SUBDIVESION\LOT3\C---_recover.dwg Date 11/17/2017 Copyright© 2002-2012 Tyco Fire Protection Products Page 12 Job: HIGHLAND JAMES SUBDIViSION (LOT3) Device Graphs Pressure vs. Flow Function Design Area: 1; Supply Ref.: 1; Supply Name-1 ::E1 . ____ so- 35 Q Q . 00 ID CD In In 17 kn Flow, gpm Pressure Loss Function Design Area: 1; BFP Ref.: 157 (WILKINS95OXL, Size 1= 1); Inlet Node: 009-I; Outlet Node: 009-0 13~- Of 4-5 2-5 CD CD C3 Flow,gpm File: Y:\ENGINEERING\3A.Project Files\C6864 HIGHLAND JAMES SUBDIVESION\LOT3\C----_recover.dwg Date 11/17/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 13 & & Job: HIGHLAND JAMES SUBDIViSION (L013) : •' Device Graphs Pressure Loss Function Design Area: 1; Valve Ref.: 156 (METER .2, Size = 1); Inlet Node: 010-I; Outlet Node: 0100 4 psi 26 gp 3-9- 3.4- 2-9- 14-- 1.4- 0-9, 0.4 ___-- I CD Flow, gpm Pressure Loss Function Design Area: 1; Valve Ref.: 158 (RESt RISER, Size = 1); Inlet Node: 012.1; Outlet Node: 012-0 4.2 psi @21 gpm - - Flow, gpm File: Y:\ENGINEERING\3A.Project Files\C6864 HIGHLAND JAMES SUBDIVESION\LOT3\C---_recover.dwg Date 11/17/2017 Copyright© 2002.-2012 Tyco Fire Protection Products Page 14 & & ____ B_________ A 4 G SPECIFICATION SUBMITTAL SHEET FEATURES Sizes: 0314" U 1" U 1-1/4" U 1-1/2' U 2' Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI 131.20.1 OPTIONS (Suffixes can be combined) U - with full port QT ball valves (standard) U L - less ball valves U U - with union ball valves U S - with bronze 'Y' type strainer U TCU - with test cocks 'vertical" up U V - with union swivel elbows (3/4" & 1") U OSY - with OS & Y gate valves U FDC - with fire hydrant connection (2" only) 0 FT - with integral male 45° flare SAE test fitting APPLICATION Designed for installation on potable water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Assembly shall provide protection where a potential health hazard does not exist. STANDARDS COMPLIANCE (All sizes approved horizontal. Vertical approvals as listed below.) ASSE® Listed 1015 ( vertical 3/4", 1 1/4", 1 1/2" & 2") IAPMO® Listed (vertical 1 1/4-2") CSA® Listed (vertical 3/4", 1 1/4", 1 1/2" & 2") AWWA Compliant C510 (vertical 3/4") UL® Classified (less shut-off valves only) C-UL® Classified (less shut-off valves only) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (vertical 3/4") City of Los Angeles Approved (vertical 1-1/4-2") NYC MEA426-89-M VOL 3 MATERIALS Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Internals Stainless Steel, 300 Series Elastomers Silicone (FDA approved) Buna Nitrile (FDA approved) Polymers NorylTM, NSF Listed Springs Stainless steel, 300 series ACCESSORIES U Repair kit (rubber only) O Thermal expansion tank (Model WXTP) U QT-SET Quick Test Fitting Set U Test Cock Lock (Model TCL24) LIJ DIMENSIONS & WEIGHTS (do not include pkg.) DIMENSIONS (a)proximate) WEIGHT MODEL A UNION LESS WITH SIZE A BALL B LE' BALL C D E F G BALL BALL VALVES VALVES VALVES VALVES in. mm in. mm in. mm in. I mm in. mm in. I mm in. mm in. I mm in. immIbsIbs. kg 3/4 20 Ill1/4 2861 12 1/2 3181 7 178 11/2 38 3 76 31/2 89 3 76 15 381 5 2.3 7 3.2 1 25 121/4 311 137/8 353 7 178 11/2 38 3 76 31/2 89 3 76 173/4 451 8 36 12 5.4 11/4 32 151/2419 181/2 470 109/16 268 2 51 31/2 89 41/2 114 41/2 114 211/2 546 16 7.3 22 10 1 1/2 40 171/8435 191/8 486 109/16 268 2 51 31/2 89 41/2 114 41/2 114 223/4 578 16 7.3 22 10 2 50 181/4460 20 508 109/16 268 2 51 31/2 89 41/2 114 l 1/2 114 251/8 638 1617.3128 12.7, 1F1II] BF-950XL 7/12 Page 1 of 2 WiLKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805-238.7100 Fax:805-238.5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1 L2 Phone:905-405-8272 Fax:905-405-1292 Product Support Help Line: 877-BACKFLOW (877-222-5356) Website: http://www.zurn.com U) 15 0. jn I FLOW CHARACTERISTICS MODEL 950XL 3/4", 1', 11/4", 11/2" & 2" (STANDARD & METRIC) FLOW RATES (us) 1.26 2.52 3.8 5.0 3.2 6.3 9.5 :3/4 (20mm) 1" (25," 10 1/4 (32rnm):1 1/2 (40mm) 10 5 A IL 1 °- 0 20 40 60 80 0 50 FLOW RATES (GPM) 0 Rated Flow (Established by approval agencies) 12.6 15.8 m 103 69 U) 2' (50mm) 0 w U) U) w Of 100 150 200 250 - TYPICAL INSTALLATION Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. OUTDOOR INSTALLATION Capacity thruSchedule 40 Pipe Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 1/8" 1 1 2 3 1/4" 2 2 3 5 3/8" 3 4 6 9 1/2 5 1 7 9 14 3/4" 8 12 17 25 13 20 27 40 1 1/4' 23 35 47 70 1 1/2" 32 48 63 95 52 78 105 167 DIRECTION OF FLOW INDOOR INSTALLATION SPECIFICATIONS The Double Check Valve Backflow Preventer shall be ASSE® Listed 1015 approved, and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat rings and all internal polymers shall be NSF® Listed NorylTM and the seat disc elastomers shall be silicone. The first and second checks shall be acces- sible for maintenance without removing the device from the line. The Double Check Valve Backflow Preventer shall be a WILKINS Model 950XL. WILKINS a Zurn company, 1747 commerce Way, Paso Robles, CA 93446 Phone: 805-238-7100 Fax:805-238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1 L2 Phone:905-405-8272 Fax:905-405-1292 Product Support Help Line: 877-BACKFLOW (877-222-5356) Website: http://www.zurn.com Page 2 of 2 Item Description 1 Manifold Body, Male Thread x Male Thread 2 Inline Check Valve, Spring Loaded 3 Flow Switch with Retard 4 Drain Valve, with optional pressure relief valve 5 Pressure Gauge, 0-300 psi National Fire Products, LLC R ES I - RISERTM The RESI-RISERTM is a pre-assembled, compact, attractive fire sprinkler riser unit for residential sprinkler systems in accordance with NFPA 13, 13R and 13D. The RESI-RISERTM manifold is manufactured as a one- piece casting that is air-tested for leaks. Raised lettering on both sides allows the RESI-RISERTM to be installed to the right or left and easily identifies the flow direction and Test and Drain outlet. Two mounting legs are molded onto the manifold allowing for a secure right or left anchoring. The flow switch has dual SPDT switches and a retard of 0-90 seconds. An optional "all in one" cost saving combination Pressure Relief Valve/Test and Drain Valve is available. The RESl-RISERTM unique design gives the ability to be installed within standard 2 x 4 frame construction. Every size RESI-RISERTM fits within a 2 x 4 wall framed at 16 inches on center. Technical Data Sizes: 1", 11/41', 11/2", and 2" Style: Thread x Thread Listing: Flow Switch and Pressure Gauge are UL Listed Finish (Riser Body): Cast Brass Water Pressure Gauge: 0-300 psi Optional Accessories: 175 psi Pressure Relief Valve/Test and Drain US Patent # 6,076,545 RESI-RISERTM Size Chart Description 1" 11/4" 11/2" 2" Height* 13" 13" 13" 13" Width** 10-3/4" 11-1/2" 12" 12-1/2" Depth 3-1/2" 3-1/2" 3-1/2" 3-1/2" Drain Size 1/2" 1" 1" 1" Dimensions include all spacing needed to operate drain valve and remove flow switch cover * Without check valve ** With or without pressure relief valve © National Fire Products, LLC (800) 528-7978 lormal Position - tatic Pressure Pressure Loss Tables Pressure Loss in 1" Resi-Riser 12 Pressure Relief/Test and Drain How it Works Relieving Pressure Exceeding 175 psi --S.- _ II_ _ I S I I .1 Pressure Loss in 1-1/4" Resi-Riser WOPO SU CL 0 0 10 15 20 25 30 35 40 45 50 55 60 Flow (gpm) Manual Open — Drain C or Flow Switch Test I1&vn2 =1 IIRIIIIIIIlIPdI ivauaiivai•iii P!iiIIUUIIUU•I S I S 5 4 ' S .5 • s :1 :' Pressure Loss in 2" Resi-Riser ocked Closed for lydrostatic Test 0 0 15 25 35 45 55 65 75 85 95 - Flow (gpm) © National Fire Products, LLC (800) 528-7978 HYDRAULIC CALCULATIONS for Job Information Project Name: HIGHLAND JAMES SUBDIVISION (LOT3) Contract No. : C6864 City: CARLSBAD, CA 92008 Project Location: 3981 JAMES DR. Date: 11/17/2017 Contractor Information Name of Contractor: INNOVATIVE FIRE PROTECTION, INC. Address: 8779 COTTONWOOD AVE.,STE. 101 City: SANTEE, CA 92071 Phone Number: 619-593-8200 E-mail: DAVIN@IFPINC.NET Name of Designer: DAVIN BROOKS Authority Having Jurisdiction: CARLSBAD FIRE AUTHORITY Design Remote Area Name 2 Remote Area Location GREATROOM Occupancy Classification RESIDENTIAL Density (gpm/ft2) 0.051 Area of Application (ft2) 512 Coverage per Sprinkler (ft2) 256 Number of Calculated Sprinklers 2 In-Rack Demand (gpm) 0 Special Heads Hose Streams (gpm) 5 Total Water Required (incl. Hose Streams) (gpm) 31.1 Required Pressure at Source (psi) 63.5 Type of System Wet Volume - EntireSystem (gal) 18.6 gal Water Supply Information Date 11/15/2017 Location CITY OF CARLSBAD Source 1 Notes File: C:\Users\davin\appdata\local\temp\C----_recover_1_1_9812.sv$ Date 11/17/2017 Copyright ©2002-2O12Tyco Fire Protection Products Page 1 Job: HIGHLAND JAMES SUBDIVISION (LOT3) Node Labels: Off Pipe Labels: Off Diagram for Design Area: 2 1flntumi7prj Hvdiraiflir Simnlifiprfl File: C:\Users\davin\appdata\IocaI\temp\C---_recover_1_1 _9812.sv$ Date 11/17/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 2 Job: HIGHLAND JAMES SUBDIVISION (LO13) Hydraulic Analysis for: 2 Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft3) Fluid Dynamic Viscosity, (lb•s/ft2) Water Supply Parameters Supply 1:1 Supply Analysis Demand Hazen-Williams Water © 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Flow (gpm) Pressure (psi) 0 76.4 500 67.4 Node at Source I Static Pressure I Residual Pressure I I Flow i I Available I i Pressure I Total Demand I I Required Pressure (psi) j (psi) (gpm) I I (psi) (gpm) I I (psi) 1 76.4 67.4 500 76.3 J 31.1 63.5 Hoses Inside Hose Flow/ Standpipe Demand (gpm) 5 Outside Hose Flow (gpm) 0 Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) 0 Total Hose Flow (gpm) 5 Sprinklers Ovehead Sprinkler Flow (gpm) 26.1 InRack Sprinkler Flow (gpm) 0 Other (custom defined) Sprinkler Flow (gpm) 0 Total Sprinkler Flow (gpm) 26.1 Other Required Margin of Safety (psi) 0 1 -Pressure (psi) 63.5 1 - Flow (gpm) 31.1 Demand w/o System Pump(s) N/A File: C:\Users\davin\.appdata\local\temp\C----_recover_1_1_9812.sv$ Date 11/17/2017 Copyright© 2002-2012 Tyco Fire Protection Products Page 3 . U) U C.) = q L. U I IT .rsd '&Jfl.d Job: HIGHLAND JAMES SUBDIVISION (LOT3) Hydraulic Analysis for: 2 Graph Labels Label Description Values Flow (gpm) Pressure (psi) SI Supply point #1 -Static 0 76.4 S2 Supply point #2-Residual 500 67.4 Dl Elevation Pressure 0 5.6 D2 SystemDemand 31.1 63.5 Curve Intersections & Safety Margins Curve Name Intersection Safety Margin Pressure (psi) Flow (gpm) 1 Pressure (psi) . © Flow (gpm) Supply 76.3 34.7 12.8 31.1 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi1/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) BI Overhead Sprinkler 256 4.9 0.051 13.1 7.1 0.051 13.1 7.1 B2 Overhead Sprinkler 0.051 256 r4.9 13.1 7.1 0.051 13.1 7.1 File: C:\Users\davin\appdata\local\temp\C----_recover_1_1 _9812.sv$ Date 11/17/2017 Copyright© 2002-2012 Tyco Fire Protection Products Page 5 Job: HIGHLAND JAMES SUBDIVISION (LOT3) Hydraulic Calculations / Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge m/ 5 1/2 gp p gpm ft2 psi psi It gpm gpm/ft2 psi gpm 81 Overhead Sprinkler 4.9 13.1 256 7.1 7.1 10 HEAD Open 0 0.051 -5.6 13.1 B2 Overhead Sprinkler 4.9 13.1 256 7.1 7.1 10 HEAD Open 0 0.051 -5.6 13.1 097 Node 8.5 11 NODE -6.1 052 Node 17.4 21 NODE -10.4 043 Node 18.8 11 NODE -6.1 057 Node 19.2 21 NODE -10.4 058 Node 19.4 21 NODE -10.4 020 Node 24.5 11 NODE -6.1 012-0 Node 32.1 5.5 NODE -3.7 012-I Node 37.6 5 NODE -3.5 011 Node 40.5 0 NODE -1.3 003 Node 43 -3 NODE 0 GPM1 Inside Hose 44.4 -3 HOSE 0 5 001 Node 44.4 -3 NODE 0 009-0 Node 44.5 -3 NODE 0 009-I Node 50.6 -3 NODE 0 010-0 Node 51.3 -3 NODE 0 010-I Node 55.3 -3 NODE 0 1 Supply 3 - 1.1 63.5 -3 SUPPLY 0 File: C:\Users\davin\appdata\local\temp\C---_recover_1_1 _9812.sv$ Date 11/17/2017 Copyright© 2002-2012 Tyco Fire Protection Products Page 6 Job: HIGHLAND JAMES SUBDIVISION (LOT3) Hydraulic Calculations / Fluid Delivery Time Analysis Pipe Data Path # Type Schedule HWC Fittings Length Flow Fr.Resist. Vel.Pres. Start Pipe Ref. Hgroup Size Rough. Eq.Len. Total Len. Velocity Loss Frict. Loss Elev. End ft gpm psi/ft psi in ft ft ft/s psi psi 1 Brline CPVC 150 1(BM.Tee-Br);2(BM.90); 8.71 13.1 0.0947 0.3 097 103 PIPE .75 0.000084 11 19.71 6.98 1.9 -0.4 Bi 1 Brline CPVC 150 1(BM.Tee-Run);1(BM.Tee-Br); 26.09 26.1 0.3421 1.3 043 099 PIPE .75 0.000084 4 30.09 13.97 10.3 0 097 1 Brline CPVC 150 8(BM.Tee-Run); 43.81 14.1 0.1089 0.4 020 022 PIPE .75 0.000084 8 51.81 7.53 5.6 0 043 1 Cmain CPVC iso 1(couphng);3(BM.90);1(BM.Tee-Ru 24.5 26.1 0.1111 0.5 012-0 014 PIPE 1 0.000084 . ee- r), 47.41 8.8 5.3 2.4 020 22.91 1 VALVE RESI RISER 0 0.5 26.1 10.5228 0 012-I 158 VALVE 1 0 0 5.3 0.2 012-0 1 Cmain CPVC 150 1(coupling); 5 26.1 0.1111 0.5 011 013 PIPE 1 0.000084 1.91 6.91 8.8 0.8 2.2 012-1 1 Cmain Copper L 150 1(coupling);1(us.90); 3.51 26.1 0.1574 0.7 003 011 PIPE 1 0.000084 4.05 7.55 10.16 1.2 1.3 011 1 Cmain PVC150 150 1(us.Tee-Run);4(BM.45);1(BM.90); 63.28 26.1 0.0175 0.1 001 005 PIPE 1.5 0.000084 16 79.28 4.12 1.4 0 003 1 Cmain PVC150 150 1(coupling); 0.4 31.1 0.0242 0.2 009-0 002 PIPE 1.5 0.000084 1.51 1.91 4.9 0.0 0 001 1 BFP WILKINS950XL 0 0 79 31.1 7.7753 0 009-I 157 BFP 1 0 . 0 6.2 0 009-0 1 Cmain Copper K 150 1(coupling); 1.5 31.1 0.2516 1.1 010-0 003 PIPE 1 0.000084 1.17 2.67 12.84 0.7 0 009-1 1 VALVE METER 0 31.1 8 0 010-I 156 VALVE 1 0 05 0 4 0 010-0 1 Cmain Copper 150 31.1 0.2516 1.1 1 004 PIPE 1 0.000084 3276 12.84 8.2 0 010-1 2 Brline CPVC 150 1(BM.Tee-Br);2(BM.90); 8.57 13.1 0.0948 0.3 097 101 PIPE .75 0.000084 11 19.57 6.99 1.9 -0.4 B2 3 Cmain Copper K 150 1(us.Tee-Br); 0.5 5 0.0085 0.0 001 001 PIPE 1 0.000084 5.84 6.34 2.06 0.1 0 GPM1 4 Brline CPVC 150 3(BM.Tee-Br);2(BM.90); 18.62 12 0.0815 0.3 052 053 PIPE .75 0.000084 17 35.62 6.44 2.9 -4.3 043 4 Brline CPVC 150 4(BM.Tee-Run);1(BM.90); 47.57 7.4 0.0331 0.1 057 054 PIPE .75 0.000084 8 55.57 3.96 1.8 0 052 4 Brline CPVC 150 1(BM.Tee-Br); 1.8 7.4 0.0331 0.1 058 059 PIPE .75 0.000084 3 4.8 3.96 0.2 0 057 4 Brline CPVC 150 1(BM.Tee-Br);2(BM.90); 12.88 12 0.0265 0.1 020 095 PIPE 1 0.000084 15 27.88 4.06 0.7 4.3 058 5 Brline CPVC 150 13(BM.Tee-Run);2(BM.Tee-Br);4(B 108.45 4.6 0.0139 0.0 058 060 PIPE .75 0.000084 143.45 2.48 2 0 052 35 File: C:\Users\davin\appdata\local\temp\C----_recover_1_1_9812.sv$ Date 11/17/2017 Copyright© 2002-2012 Tyco Fire Protection Products Page 7 Job: HIGHLAND JAMES SUBDI'ASION (L013) Hydraulic Calculations/ Fluid Delivery Time Analysis Pipe Data Start Disch. Start Tot.Pres. End Disch. End Tot.Pres. gpm psi gpm psi 8.5 13.1 7.1 18.8 8.5 24.5 18.8 32.1 24.5 37.6 32.1 40.5 37.6 43 40.5 44.4 43 44.5 44.4 50.6 44.5 51.3 50.6 55.3 51.3 -31.1 63.5 553 8.5 13.1 7.1 44.4 5 44.4 17.4 18.8 19.2 17.4 19.4 19.2 24.5 19.4 19.4 17.4 File: C:\Users\davin\appdata\local\temp\C---_recover_1 _1_9812.sv$ Date 11/17/2017 Copyright© 2002-2012 Tyco Fire Protection Products Page 8 Job name: HIGHLAND JAMES SUBDIViSION (LO13) Sheet number: PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added(q)* Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F P1 per ft elev (Pe) NOTES T frict (P1) (It) (gpm/psil/2) (gpm) (in) (It) (It) (psi) (psi) Bi 10 4.9 13.1 .75 lx(BM.Tee-Br)=3 8.71 150 7.1 097 11 13.1 0.874 2x(BM.90)=8 11 0.0947 -0.4 19.71 1.9 097 11 13.1 .75 lx(BM.Tee-Run)=1 26.09 150 8.5 043 11 26.1 0.874 lx(BM.Tee-Br)=3 4 0.3421 0 30.09 10.3 043 11 -12 .75 8x(BM.Tee-Run)=8 43.81 150 18.8 020 11 14.1 0.874 8 0.1089 0 51.81 5.6 020 11 12 1 lx(coupling)=1.91 24.5 150 24.5 012-0 5.5 26.1 1.101 3x(BM.90)=15 22.91 0.1111 2.4 lx(BM.Tee-Run)=1 47.41 5.3 lx(BM.Tee-Br)=5 012-0 5.5 0 1 0.5 0 32.1 RESI RISER 012-1 5 26.1 0 0 10.5228 0.2 *** 0.5 5.3 012-I 5 0 1 lx(coupling)=1.91 5 150 37.6 011 0 26.1 1.101 1.91 0.1111 2.2 6.91 0.8 011 0 0 1 lx(coupling)=1.35 3.51 150 40.5 003 -3 26.1 1.025 lx(us.90)=2.7 4.05 0.1574 1.3 7.55 1.2 003 -3 0 1.5 4x(BM.45)=8 63.28 150 43 001 -3 26.1 1.61 lx(BM.90)=8 16 0.0175 0 79.28 1.4 001 -3 5 1.5 lx(coupling)=1.51 0.4 150 44.4 009-0 -3 31.1 1.61 1.51 0.0242 0 1.91 0.0 009-0 -3 0 1 0.79 0 44.5 WILKINS95OX 009-1 -3 31.1 0 0 7.7753 0 L 0.79 6.2 *** 009-I -3 0 1 lx(coupling)=1.17 1.5 150 50.6 010-0 -3 31.1 0.995 1.17 0.2516 0 2.67 0.7 010-0 -3 0 1 0.5 0 51.3 METER 2 010-I -3 31.1 0 0 8 0 *** 0.5 4 010-1 -3 0 1 32.76 150 55.3 1 -3 31.1 0.995 0 0.2516 0 32.76 8.2 B2 10 4.9 13.1 .75 lx(BM.Tee-Br)=3 8.57 150 7.1 097 11 13.1 0.874 2x(BM.90)=8 11 0.0948 -0.4 19.57 1.9 GPM1 -3 5 1 lx(us.Tee-Br)=5.84 0.5 150 44.4 001 -3 5 0.995 5.84 0.0085 0 6.34 0.1 043 11 0 .75 3x(BM.Tee-Br)=9 18.62 150 18.8 052 21 12 0.874 2x(BM.90)=8 17 0.0815 -4.3 35.62 2.9 052 21 -4.6 .75 4x(BM.Tee-Run)=4 47.57 150 17.4 057 21 7.4 0.874 lx(BM.90)=4 8 0.0331 0 55.57 1.8 © 2006 National Fire Protection Association Page 9 Job name: HIGHLAND JAMES SUBDIVISION (LOT3) Sheet number: PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added(q)* Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (P0 (ft) (gpm/psi'/2) (gpm) (in) (ft) (ft) (psi) (psi) 057 21 0 .75 1x(BM.Tee-Br)=3 1.8 150 19.2 058 21 7.4 0.874 3 0.0331 0 4.8 0.2 058 21 4.6 1 lx(BM.Tee-Br)=5 12.88 150 19.4 020 11 12 1.101 2x(BM.90)=10 15 0.0265 4.3 27.88 0.7 052 21 0 .75 13x(BM.Tee-Run)=13 108.45 150 17.4 058 21 4.6 0.874 2x(BM.Tee-Br)=6 35 0.0139 0 ______ _ ________ 4x(BM.90)=16 143.45 2 * Discharge shown for flowing nodes only © 2006 National Fire Protection Association Page 10 Job: HIGHLAND JAMES SUBDIVISION (LOT3) Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (9pm/psi'/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: I BI 10 4.9 13.1 .75 lx(BM.Tee-Br)=3 8.71 150 7.1 097 11 13.1 0.874 2x(BM.90)=8 11 0.0947 -0.4 19.7.1 1.9 097 11 13.1 .75 lx(BM.Tee-Run)=1 26.09 150 8.5 043 11 26.1 0.874 lx(BM.Tee-Br)=3 4 0.3421 0 30.09 10.3 043 11 -12 .75 8x(BM.Tee-Run)=8 43.81 150 18.8 020 11 14.1 0.874 8 0.1089 0 51.81 5.6 020 11 12 1 lx(coupling)=1.91 24.5 150 24.5 012-0 5.5 26.1 1.101 3x(BM.90)=15 22.91 0.1111 2.4 lx(BM.Tee-Run)=1 47.41 5.3 lx(BM.Tee-Br)=5 012-0 5.5 0 1 0.5 0 32.1 RESI RISER 012-1 5 26.1 0 0 10.5228 0.2 *** 0.5 5.3 012-I 5 0 1 lx(coupling)=1.91 5 150 37.6 011 0 26.1 1.101 1.91 0.1111 2.2 6.91 0.8 011 0 0 1 lx(coupling)=1.35 3.51 150 40.5 003 -3 26.1 1.025 lx(us.90)=2.7 4.05 0.1574 1.3 7.55 1.2 003 -3 0 1.5 4x(BM.45)=8 63.28 150 43 001 -3 26.1 1.61 lx(BM.90)=8 16 0.0175 0 79.28 1.4 001 -3 5 1.5 lx(coupling)=1.51 0.4 150 44.4 009-0 -3 31.1 1.61 1.51 0.0242 0 1.91 0.0 009-0 -3 0 1 0.79 0 44.5 WILKINS95OX 009-1 -3 31.1 0 0 7.7753 0 L 0.79 6.2 *** 009-I -3 0 1 lx(coupling)=1.17 1.5 150 50.6 010-0 -3 31.1 0.995 1.17 0.2516 0 2.67 0.7 010-0 -3 0 1 0.5 0 51.3 METER 2 010-I -3 31.1 0 0 8 0 *** 0.5 4 010-1 -3 0 1 32.76 150 55.3 1 -3 31.1 0.995 0 0.2516 0 ____ 32.76 8.2 1 63.5 Path No: 2 B2 10 4.9 13.1 .75 lx(BM.Tee-Br)=3 8.57 150 7.1 097 11 13.1 0.874 2x(BM.90)=8 11 0.0948 -0.4 19.57 1.9 097 8.5 File: C:\Users\davin\appdata\Iocal\temp\C----_recover_1_1_9812.sv$ Date 11/17/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 11 :1 Job HIGHLAND JAMES SUBDIVISION (L013) Hydraulic Calculations PIPE INFORMATION Path No: 3 GPM1 -3 5 1 1x(us.Tee-Br)=5.84 0.5 150 44.4 001 -3 5 0.995 5.84 0.0085 0 6.34 0.1 001 44.4 Path No: 4 043 11 0 .75 3x(BM.Tee-Br)=9 18.62 150 18.8 052 21 12 0.874 2x(BM.90)=8 17 0.0815 -4.3 35.62 2.9 052 21 -4.6 .75 4x(BM.Tee-Run)=4 47.57 150 17.4 057 21 7.4 0.874 lx(BM.90)=4 8 0.0331 0 55.57 1.8 057 21 0 .75 lx(BM.Tee-Br)=3 1.8 150 19.2 058 21 7.4 0.874 3 0.0331 0 4.8 0.2 058 21 4.6 1 lx(BM.Tee-Br)=5 12.88 150 19.4 020 11 12 1.101 2x(BM.90)=10 15 0.0265 4.3 27.88 0.7 020 24.5 Path No: 5 052 21 0 .75 13x(BM.Tee-Run)=13 108.45 150 17.4 058 21 4.6 0.874 2x(BM.Tee-Br)=6 35 0.0139 0 4x(BM.90)=16 143.45 2 058 19.4 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 13.97 ft/s occurs in the following pipe(s): (043-097) "** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File: C:\Usersdavin\appdata\local\temp\C----_recover11 _9812.sv$ Date 11/17/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 12 Job: HIGHLAND JAMES SUBDIViSION (LOT3) Device Graphs Pressure vs. Flow Function Design Area: 2; Supply Ref.: 1; Supply Name:1 go io- 55 43 10 01 a a a a a 00 a a a a m In Flow, gpm Pressure Loss Function Design Area: 2; BFP Ref.: 157 ('W1LK1NS950XL, Size = 1); Inlet Node: 009-I; Outlet Node: 009-0 __-_-__•- {6.2psi3tIgpmfr-- - 4-5 23 0-5 CD a a a a a (N GO Flow, gpm File: C:\Users\davin\.appdata\Iocal\temp\C----_recover_1_1_9812.sv$ Date 11/17/2017 Copyright© 2002-2012 Tyco Fire Protection Products Page 13 Job: HIGHLAND JAMES SUBDIVISION (L013) Device Graphs Pressure Loss Function Design Area: 2; Valve Ref.: 156 (METER 2, Size = 1); Inlet Node: 010-I; Outlet Node: 010-0 i.igpmj__ 3.4. - - 14 1.4.-- 0.9. .. . 0.4. & 0 0 fn Flow, qpni Pressure Loss 'Function Design Area: 2; Valve Ref.: 158 (RE SI RISER, Size = 1); Inlet Node: 012-I; Outlet Node: 012-0 9.65 (5.3 psi .1 gpm 0 0 In 0 I 0 0 0 C4 - Flow, gpm File: C:\Users\davin\appdata\local\temp\C---_recover_1_1_9812.sv$ Date 11/17/2017 Copyright © 2002-2012 Tyco Fire Protection Products Page 14 & i Or i1 SENJU SPRINKLER CO.,LTD. Residential Lead Free Flat Concealed Sprinkler, Pendent. Model: RC-RES, K-Factor: 4.9, SIN: SS8464 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. These are decorative and fast response. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is in turn concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for the residential occupancies and it is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar112) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents' escape or evacuation in case of fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. "Lead Free" is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA's Water Utility Council, and California Assembly Bill #1953as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. WARNINGS The Model RC-RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. In the event of this condition, consult the authorities having jurisdiction for guidance and approval. Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or his representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. Document No. U085160 Date . Feb/09/2015 2—,tW' (52mm) 2— °/a"(168mm) or 3- Y4" (83mm) or 2— 5/a"square (068mm) Lot No. Year of Manufacture SIN : S58464 K—factor : 1(4.9 Temperature Rating : 162F/72C UL Mark or 175T/79C Control No. 6P37 NSF Mark : NSF-61—C RES SPKR Body (Copper Alloy) Q Deflector (Phosphorus Bronze) Casket (PTFE) ® Fusible Metal (Solder) 0 Heat Collector (Copper) ® Cover Plate Assembly NPT 1 FIGURE 1. Model RC-RES K=4.9 Page . 2 of 8 TECHNICAL DATA Approvals: UL5 Listed, NSF-61-G Sprinkler Identification Number (SIN): S58464 Maximum Working Pressure: 175psi (12.1bar) Discharge Coefficient (Nominal K-Factor): K=4.9 GPMIpsi112 (70.6 LPM/bar1) Temperature Rating: 1621 (72°C) Sprinkler with 1401 (60°C) Cover Plate 1751 (79°C) Sprinkler with 1621 (72°C) Cover Plate Color Code (Sprinkler) 1621 (720C): Uncolored 1751 (79°C): White Color Code (Cover Plate) 1401 (600C): No Mark 1621 (720C): White-Colored Mark Vertical Adjustment: 112 inch (12.8 mm) Cover Plate Finishes: Standard Finishes- White, Ivory, Beige, Brown, Black, Nickel, Wood Grain Custom Finishes- Custom color and custom pattern cover plates are available on special order. Contact a Senju Sprinkler representative with any custom orders. Please see chart on Page 8 for more detail. Physical Characteristics: Ref. Figure 1 Z464 X (4.9 rlure Rating 77C or 175F/79C COVER PLATE SPRINKLER (Top view) (Bottom view) OPERATION FIGURE 1-1. Marking (Color Code) In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then, the Cover Plate is released at once. As a result, the Deflector drcps down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is recorded, internal components of the sprinkler to fall apart. This leads to allow the water flow to be distributed on the affected by fire area. (Rf. Figure 2) Normal Condition Cover Plote Operation Sprinkler Operation Water Discharge FIGURE 2. OPERATION PROCESS (The figure is for illustrative purpose only) DESIGN CRITERIA Page 3 of 8 The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not coverage by the following instructions, should be submitted to Contact Company. Include sketches and technical details as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent and which take precedence over those specified in NFPA 13, 13D, 13R, or by the authority having jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air flow impediment. The spray from the sprinkler is distributed radically outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13, 13D, or 13R) must be kept as small as possible. Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided with the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13 for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 13D or 13R for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to exposure to a heat sources other than an actual fire. Precautionary Warnings for Corrosive Environments The Model RC-RES should not be installed where they may be subjected to a corrosive environment including the following: Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler system piping with Copper. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for the copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) - Solder Joint) All residual flux must be removed from the interior and exterior of copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and leakage in the sprinkler system. Hydraulic Design Criteria The minimum required sprinkler flow rates for system designed to NFPA 13D or 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of "design sprinklers" as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the followings; The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. Document No. U085160 Date : Feb/09/2015 Page 4 of 8 A minimum discharge 0.1GPM/sq.ft. [4.07LPM/sq.m] over the design area' comprised of the four most hydraulically demanding sprinklers for the actual coverage areas being protected by the four sprinklers. TABLE A. NFPA 13D & 13R WET PIPE HYDRAULIC DESIGN CRITERIA for Model SS8464 Maximum Ordinary Intermediate Coverage Maximum Temperature Rating Temperature Rating Deflector Minimum Area (a Spacing 162°F (72°C) 175°F (79°C) to Installation Spacing Flow Pressure Flow Pressure Ft. x Ft Ft. Ceiling Type Ft. (m xm) (m) GPM PSI GPM PSI (m) (LPM) (bar) (LPM) (bar) Smooth 12x12 12 13 7.0 13 7.0 Ceilings (3.7x3.7) (3.7) (49.2) (0.48) (49.2) (0.48) 3/8 to 7/8 Inches. 1404 14 13 7.0 13 7.0 (4.3x4.3) (4.3) (49.2) (0.48) (49.2) (0.48) Beamed Ceilings per NFPA 1606 16 13 7.0 14 8.2 13D,13R Concealed 8 (4.9x4.9) (4.9) (49.2) (0.48) (53.0) (0.57) or 13 (2.4) Installed in beam 1808 18 17 12.0 18 13.5 3/8 to (5.5x5.5) (5.5) (64.3) (0.83) (68.1) (0.93) 7/8 inches 20x20 20 21 18.4 below (6.1x6.1) (6.1) (79.5) (1.27) - - bottom of beam. For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. Requirement is based on minimum flow in GPM/LPM from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R or 13 as applicable. Sprinkler Spacing Criteria The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. Table A) INSTALLATION The Model RC-RES must be installed in accordance with the following instructions. NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. The Protective Cap must remain on the sprinkler during installation and until the ceiling installation is completed. The Protective Cap must be removed to place the sprinkler in service. Document No. U085160 Date . Feb/09/2015 Page: 5 of 8 Use a torque of 7 to 14 ft.lbs (9.5 to 19.ONm) to achieve a 1/2 inch NPT sprinkler joint. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Installina Procedure Step I The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler filling so that the distance from the face of the fitting to the mounting surface will be nominally 2 inch (50.8mm) as shown in Figure 3. Step 2 With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Sprinkler Socket or Wrench & Socket Combination (Ref. Figure 4). The grooves of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3 If desired the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with the 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the "Tolerance Limit of Ceiling Level" indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Make a Space Here NOT Ave. i'd" (6.4mm) er-Tighten I I Groove on the Sprinkler Mm )f (3.2mm) ' I JjD Tolerance Limit Ll Cq Protective Cop CeiIinq Ceiling Mounting Surface Groove of the Socket Mounting Surface 2-/8"(6Omm) - Socket Wrench _______ Ceiling Hole Diameter FIGURE 3. INSTALLATION FIGURE 4 Step 4 Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just comes in contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has come in contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening of the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot come in contact with the ceiling sufficiently, readjust the sprinkler filling as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6 Document No. U085160 Date : Feb/09/2015 Page : 6 of Sprinkle Step 1 r Head MUM Protective Co , :e C. Cap Remover RC step2Lj _ Hook by turning LI Step 3 4 Pull down FIGURE 5. PROTECTIVE CAP REMOVAL E E 0 U, c.J Mounting Surfo E E I DeflectorI Plate Assembly lCove r L or 3- 4 (' 83mm) or 2- 5/"square (068mm) FIGURE 6 INCORRECT IC0RRECTI INCORRECTI FIGURE 7. INSTALLATION (CORRECT OR INCORRECT) Document No. U085160 Date : Feb/09/2015 Page 7 of 8 CARE AND MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC-RES. NOTES Wet pipe sprinkler systems must be maintained at a minimum temperature of 40 F/4 IC to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non-factory applied paint may adversely delay or prevent sprinkler operation in case of afire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities and all affected by this action parties must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler systems to aid in the control of a fire involving such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must never be shipped or stored where the temperature exceeds 100°F/38°C. Automatic sprinkler must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units, as a result of dropping, hitting, over-tightening, or wrench slippage, must be replaced. The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor, the same coverage area, and the same or lower flow ratings (as indicated under Table A "Hydraulic Design Criteria"). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verity that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing, its compliance with this documents, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA25. Document No. U085160 Date Feb/09/2015 Page . 8 of 8 ORDER PROCEDURE When placing an order, please contact a local distributor with the following information (Model Name, Specify, Temp. and Finish). Sprinkler: Model: RC-RES (SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162°F (72°C) or 175°F (79°C)) Cover Plate Assembly: 2-5/8 inch (68mm) or 3-1/4 inch (83mm) or 2-5/8 inch square (068mm), Order Separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. Standard Finishes Custom Finishes White Ivory Beige Brown Black Nickel Wood grain Custom Color Custom Pattern 2-5/8" Round, 140°F 0 0 - - - 0 - 0 0 3-1/4" Round, 140°F 0 0 0 0 0 0 0 0 0 2-5/8" Square, 140°F 0 - - - - - - 0 0 2-5/8" Round, 162°F 0 - - - - - - 0 0 3-1/4" Round, 162°F 0 - - - - - - 0 0 Tools for Installation of Model: RC-RES Socket for Model RC-RES Wrench & Socket for Model RC-RES Cap Remover RC Document No. U085160 Date Feb/09/2015 Fl Res 30, 49, 58 & 76 Fl Res 30, 49, 58 & 76 Recessed Pendent I Fl Recessed Pendent / FP Fl Res 30,49,58&76 F1 Res 44&58 COP Pendent Recessed HSW/F2 Bulletin 135 Rev. M ® Model Fl Residential Sprinklers for lie 11abile Design Density of .05 gprn/ft2 Model Fl Res Sprinklers engineered for the lowest flows to meet the minimum design density of .05 gpm/ft2 Types: Fl Res 30Pendent Fl Res 30 Recessed Pendent/F2 Fl Res 30 Recessed Pendent/FP Fl Res 49 Pendent Fl Res 49 Recessed Pendent/Fl Fl Res 49 Recessed Pendent/FP Fl Res 58 Pendent Fl Res 58 Recessed Pendent/Fl Fl Res 58 Recessed Pendent/FP Fl Res 76Pendent Fl Res 76 Recessed Pendent/Fl Fl Res 76 Recessed Pendent/FP Fl Res 30 COP Pendent Fl Res 49 COP Pendent Fl Res 58 COP Pendent Fl Res 76 COP Pendent Fl Res 44 HSW Fl Res 44 Recessed HSW/F2 Fl Res 58HSW Fl Res 58 HSWX KRes58HSWX Fl Res 58 HSW Recessed HSW/F2 Fl Res 44SWC Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Sprinklers for .10 Density: Refer to Bulletin 176 UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model Fl Res 49 & 58 Pendent Sprinklers US Patent No. 7,353,882 applies to Model Fl Res 44 & 58 HSW Sprinklers US Patent No. 7,784,555 applies to Model Fl Res 44 SWC Sprinklers Product Description Model Fl Res Pendent sprinklers (Figs. 1 2, 3, & 4) are fast response sprinklers combining excellent durability, high sensitiv- ity glass-bulb and low profile decorative design. The Fl Res F-i iies ob F-IVVA Fl Res 44 SWO Horizontal Sidewall sprinklers (Figs. 5, 6 & 7) are equally attrac- tive when above ceiling piping cannot be used. The 3mm glass-bulb pendent sprinklers permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. The low flow Fl Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection applica- tion needs of the latest residential market standards (UL 1626 Standard). Upon fire conditions, rising heat causes a sprinkler heat-sensitive element, glass bulb or link to actuate, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: Thermal Sensor: Soldered Element (Link) or Nominal 3mm glass-bulb Sprinkler Frame: Brass Casting Sprinklers' Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi Thread Size: ½" NPT (R½) K-Factor: 3.0 (43.2) (Actual) - Fl Res 30 Pendent Sprinkler 4.9 (70.6) (Actual) - Fl Res 49 Pendent Sprinkler 5.8 (83.5) (Actual) - Fl Res 58 Pendent & HSW Sprinkler 7.6 (109)(Actual) - Fl Res 76 Pendent Sprinkler 4.4(63) (Actual) - Fl Res 44 HSW Sprinkler Density: Minimum 0.05 gpmlft2 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Model Fl Res Sprinklers are used for Residential Fire Pro- tection according to UL 1626 Standard*. For ceiling types: Smooth Flat Horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R, or 132013 editions. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The Na- tional Fire Protection Association or the approving authority having jurisdiction. Installation Models Fl Res sprinklers are to be installed as shown. Model Fl, F2 and FP Escutcheons, illustrated herewith, are 1 nr ') flti" the only recessed escutcheons to be used with Model Fl Res sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res Pen- dent sprinklers use only the Model D sprinkler Wrench; for installing Models Fl Res Recessed Pendent, COP & SWO sprinklers use only the Model GFR2 sprinkler wrench; for in- stalling Model Fl Res Recessed HSW sprinklers use only the Model GFR2 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install Fl Res 44 with a ceiling to deflector distance of 4" - 12". Flow arrow on deflector must point away from near wall and "Top" mark- ing must face ceiling. It Type Adjustment "A" Face of fining to ceiling Deflector Distance below bottom of beam Inch (mm) Inch (mm) Inch (mm) Inch (mm) Mm. Recessed = 1/8 (41.3) 3/8 (9.5) 1/4 (44.4) Fl 3/4 (19.0) Max. Recessed =/s (22.2) 11/8 (28.6) 1(25.4) Mm. Recessed = 1/a (41.3) 3/8 (9.5) 13/,,(44.4) F2 1/2 (12.7) Max. Recessed =11/8 (28.6) /8(22.2) 11/4 (31.7 * Note: Escutcheons Fl or F2 may be used with Model F-i Hes 49, 58 & lb Kecessec i-enaent prinicier Model Fl Res 30 Recessed Pendent / F2 • Model Fl Res 30, 49, bb & (b renae nt • Modi I I-i ties 4% ots & lb Kecesseu ren lent/Fl Fl escutcheon, 3/4" (19mm) adjustment TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. im ADJUSTMENT 2 1/4" HOLE OH. — [57.2"m] - I' 75/76" 014. "1 2 27/32" OIA. X 1/2 REOUCER 1/8' _J 'a" 'ACE OP FIllING TO CEILING DIMENSION: 3/8—1 7/8" (VI ESCUTCHEON) 3/8-7/8" (P2 ESCUTCHEON) Fig. 1 Fig. 2 Ti'hnirI flth F1 Res fl Pendent and Recessed Pendent (SIN R3511) Thread Size I Nominal Orifice Inch (mm) I Max. Pressure I psi (bar) I Sprinkler Temp. Rating I Max. Ambient Temp. I Actual K Factor I Sprinkler Length I Inch (mm) OF "C OF I °C Y2"NPT I 2l/ " (8.2) 175 (12) 155 68 I 100 38 3.0(43.2) 2.25 (57) (R½) I I 175 I 79 I Max. Ordinary Temp. Rating Intermediate Temp. Rating Minimum Max. Coverage area Spacing (155°F/68°C) (1750F1790C) Top of Deflector to Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (L/min) PSI (bar) GPM (Llmin) PSI (bar) 12 x 12 (3,6 x 3,6) 12(3.6) 8(30,3) 7.0 (0,48) 8 (30,3) 7.0(0.48) Smooth Ceilings l~to 4(31.7 to 102) using F2 escutcheon. Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 11/4 to 13A 8(2.4) 14 x 14 (4,3 x 4,3) 14(4,3) 10 (37,8) 11(0,76) 10 (37,8) 11(0,76) 16 X 16(4,9 X 4,9) 16(4,9) 13(49) 18.8(1,3) 13(49) 18.8(1,3) (31.7 to 44.4) using F2 escutcheon For Ceiling types refer to NFPA 13, 13R or 130 2. Technical Data: F1 Res 49 Pendent and Recessed Pendent (SIN R3516) Thread Nominal Orifice I Max. I Sprinkler I I Max. I I Actual I I Sprinkler I Size Inch (mm) Pressure I Temp. Rating j Ambient Temp. I K I I Length I OF IOC OF C psi (bar) Factor I Inch (mm) I ½" NPT (R½) I I 175(12) I 155 175 68 I 79 I 100 I 150 38 I 66 4.9(70,6) 2.25 (57) Ordinary Temp. Rating Intermediate Temp. Rating Max. Coverage area Max. Spacing (1 55°F,8°C) (175°F/79°C) lop of Deflector Minimum Ft x Ft (mx m) Ft (m) to Ceiling Spacing Flow Pressure Flow Pressure _____ GPM (1/mm) PSI (bar) GPM (L/min) PSI (bar) Inch (mm) Ft (m) 12x 12(3,6x3,6) 12(3,6) 13(49) 7.0 (0,48) 13(49) 7.0(0,48) Smooth Ceilings 11/4 t04(31.7t0 102) using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 13 (49) 7.0 (0,48) 13 (49) 7,0(0,48) 1 t 4(25.4 to 102) using Fl escutcheon. 16x 16(4,9x4,9) 16(4,9) 13(49) 7.0(0,48) 13(49) 7.0(0,48) Beamed Ceilings per NFPA 130, 13R 0113 installed in 8 (2,4) 18 x 18(5,5 x 5,5) 18(5,5) 17(64,3) 12(0,83) 17(64,3) 12(0,83) beams 11/4 to 1/4 (31.7 to 44.4) using F2 escutcheon, 1 20 x 20(6,1 x 6,1) 20(6,1) 20 (75,7) 16.7(l.14) 20 (75,7) 16,7(1,14) to 134(25.4to44.4) using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 130 Max. Coverage area Max. Spacing Ordinary Temp. Rating (1550F)8°C) Intermediate Temp. Rating (1750F/790C) Top of Deflector Minimum FtxFt(mxm) Ft (m) to Ceiling Spacing Flow Pressure Flow Pressure GPM (L.knin) PSI (bar) GPM (LIiin) PSI (bar) Inch (mm) Ft (m) 12 x 12 (3,6 x 3,6) 12(3.6) 15 (57) 9.4 (0,65) 15 (57) 9.4 (0,65) Smooth Ceilings 4108 (100 to 203) using F2 escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 16(60,5) 10.6(0,73) 16(60,5) 10.6(0,73) 4t0 8(100 to 203) using Fl escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 17(64,3) 12.0(0,83) 17(64,3) 12.0(0,83) Beamed Ceilings per NFPA 130, 13R or 13 installed in beams 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 19(72) 15.0 (1,0) 19(72) 15.0 (1,0) 41/4 to 8(108 to 203) using F2 escutcheon, 4 to 8(100 to 203) 20x20(6,1 x6,1) 20(6,1) 22 (83,2) 20.2(1,4) 22 (83,2) 720.2(1,4) using Fl escutcheon Technical Data: F1 Res 58 Pendent and Recessed Pendent (SIN R3513) Thread Nominal Orifice Max. I Sprinkler I I Max. Actual Sprinkler I Size Inch (mm) Pressure I Temp. Rating I Ambient Temp. K Factor Length I OF °C I OF I °C psi (bar) I Inch (mm) ½" NPT (R½) ½' (13) 175 (12) 155 I 175 66 68 I 79 100 150 38 I 5.8(83.5) 2.25 (57) Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (155°Fi8°C) (175°F/79°C) Ft x Ft (mx m) Ft (m) to Ceiling Spacing Flow Pressure Flow Pressure GPM (Lknin) PSI (bar) GPM (L PSI (bar) Inch (mm) Ft (m) 12 x 12(3,6 x 3,6) 12(3,6) 16 (61) 7.6(0,53) 16(61) 7.6(0,53) Smooth Ceilings 11/4 to 4 (31.7 to 02) using F2 escutcheon. 14x 14(4,3x4,3) 14(4,3) 16(61) 7.6(0,53) 16(61) 7.6(0,53) 1 t04(25.4t0102) using Fl escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 16(61) 7.6(0,53) 16 (61) 7.6(0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 8(2,4) - 18 x 18(5,5 x 5,5) 18(5,5) 19(72) 10.8(0,75) 19(72) 10.8 (0,75) 11/4 to 13A (31.7 to 44.4) using F2 escutcheon, 1 t 1/4 (25.4 to 20 x 20 (6,1 x 6,1) 20(6.1) 22(83,3) 14.4(l.0) 22 (83,3) 14.4 (1,0) 44.4) using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 130 3. Trhnil flth Fl Rs 76 Pendent and Recessed Pendent (SIN R7618) I I Max. Sprinkler I Max. K I Sprinkler Thread Nominal Orifice I I Pressure Temp. Rating Ambient Temp. F actor Length I I °C Size Inch (mm) I psi (bar) Inch (mm) 3/4' NPT 17/32" (13.5) 175(12) 155 175 68 I 79 I 100 150 38 I 66 7.6(109) 2.25 (57) (R3/4) Ordinary Temp. Rating Intermediate Temp. Rating Minimum Max. Coverage area Max. Spacing (1 55°Fit8°C) (175°F/790C) Top of Deflector to Ceiling Ft x Ft (m x m) Ft (m) Flow Pressure Flow GPM Pressure Inch (mm) Spacing Ft(m) 12 x 12 (3,6 x 3,6) 12(3,6) 21 (79,5) 7.6 (0,53) 21(79,5) 14 x 14(4,3 x 4,3) 14(4,3) 21(79,5) 7.6 (053) 21(79,5) 16 x 16(4,9 x 4,9) 16(4,9) 21(79,5) 7.6 (0,53) 21(79,5) 18 x 18(5,5 x 5,5) 18(5,5) 21(79,5) 7.6(0,5 ) 21(79,5) 20x20(6,1 x6,1) 20(6,1) 23(87,1) 9.2(0,63) 23(87,1) For Ceiling types refer to NFPA 13, 13R or 13D Model Fl Res 30, 49, 58 & 76 CCP Pendent* 7.6(0,53) Smooth Ceilings 41/4 to 8 (108 to 203) using F2 escutcheon. 7.6(0,53) 4 to 8(100 to 203) using Fl escutcheon. 7.6 (0,53) Beamed Ceilings per NFPA 8(2,4) 13D, 13R or 13 installed in 7.6(0,53) beams 41/4 to 8(108 to 203) us- ing F2 escutcheon, 4 to 8(100 9.2 (0,63) to 203) using Fl escutcheon Model Fl Res 30, 49, 58 & 76 Qd Dnrint I FP * Not listed for corrosion resistance. 2 5/8" (65.7mm] 0/A. 2 5/I6 OIA. - HOLE IN CEILING [58.7mm] - CUP r' i ,.---- 1"xl/2" REDUCER CUP CEILING ______ MAX ACPOF5FdNC ' JI Il III l TO FACE OF CEILING . ....DIMENSION COVER ADJUSTMENT HEIGHT 3 5/16" OIA. 1J5FG04E [84.7mm] Fl RES 30, 49, 58 & 76 CCP PEND. Fig. 3 Note: The Fl Res 76 will use a 1" x 3%" reducer. CCP Cover Plate Data: "C,, Deflector Distance below bottom Cover Adjustment CCP Height of beam Inch (mm) Inch (mm) Inch (mm) 1/2(12.7) 15/16 (24) ½(13)- 1(25.4) /16(7.9) /4(19) 1 ½ (13)- 1(25.4) i-v pusfl-on/tflreaa-o1T escutcneon 2 5/8" 0/A. [66.7mm] -HOLE IN CEILING - 2 5/76" 0/A. - (58.7mm] - C ( I - I" X 1/2" REDUCER :T7 CEILING 1 1/ __ 2[38. 1mm] MAX. FACE OF FITTING TO FACE OF CEILING 1/2" [13mm] MAX.J fl',, FP ADJUSTMENT I I Fl RES 49 PENDENT/FP Fig. 4 FP Escutcheon Data: "B" "A" Deflector Distance below bottom FP Position Inch (mm) of beam Inch (mm) Max. Recessed /16(11) ½(12.7) Mm. Recessed 15/16(24) 1 (25.4) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in Ceilings which have positive pressure in the space above, 4. Technical Data: F1 Res 30 CCP Pendent and Recessed Pendent/FP (SIN R3511) Thread Nominal I Max. I CCP Assembly I Max. K Sprinkler Size Orif ice Pressure Temp. Rating Ambient Temp. Length °F I °C I I °F I °C Inch (mm) J psi (bar) Factor i I Inch (mm) I 1/2"NPT (R1/2) 21/,"(8.2) 175(12) 135 57 100 T38 3.0 (43.2) 2.25 (57) Ordinary Temp. Rating Max. Coverage area Max. Spacing (155'F/680C) Top of Deflector to Ceiling Minimum Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Spacing GPM (11mm) PSI (bar) Ft (m) 12 X 12(3,6 X 3,6) 12(3,6) 8(30,3) 7.0(0,48) Smooth Ceilings ½ to 1(13 to 25.4) using COP. ½ to 1(13 to 25.4) using FP escutcheon. Beamed Ceilings per NFPA 13D, 13R 0113 installed in 8(2.4) 14 x 14(4,3 x 4,3) 14(4,3) 11(37,8) 13.4(0,92) beams ½ to 1(13 to 25.4) using OCR ½ to 1(13 to 25.4) using FP escutcheon. For Ceiling types refer to NFPA 13, 13R or 130 Technical Data: F1 Res 49 CCP Pendent and Recessed PendentlFP (SIN 3516) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing (155°F/68°C) Top of Deflector to Ceiling Spacing Ft x Ft (m x m) Ft (m) Flow Pressure Inch (mm) Ft (m) GPM (lJmin) PSI (bar) 12x 12(3,6x3,6) 12(3,6) 13(49) 7.0 (0,48) Smooth Ceilings ½ to 1(13 to 25.4) using 14 x 14 (4,3 x 4,3) 14(4,3) 13 (49) 7.0 (0,48) CCP. 112 to 1(13 to 25.4) using FP escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 14(53) 8.2 (0,56) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams ½ to 1(13 to 25.4) using 8(2,4) 18x 18(5,5x5,5) 18(5,5) 18(68,1) 13.5 (0,93) CCP. 1/2 to 1(13 to 25.4) using FP escutcheon. 20 x 20 (6,1 x 6, 1) 20(6,1) 20(75,7) 16.7(1,14) For Ceiling types refer to NFPA 13, 13R 01130 Technical Data: F1 Res 58 CCP Pendent and Recessed PendentlFP (SIN R3513) Thread Nominal I Max. I CCP Assembly I Max. I I K I Sprinkler I I Size Orifice Pressure Temp. Rating Ambient Temp. I Factor Length I OF °C OF °C Inch (mm) psi (bar) I I Inch (mm) I ½" NPT (R½) 1/2"(13) I 175(12) 135 57 100 38 5.8 (83.5) 2.25 (57) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing (155' 8-C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) 12 x 12 (3,6 x 3,6) 12(3,6) 16(61) 7.6(0,53) Smooth Ceilings ½ to 1(13 to 25.4) using CCP. '/2 to 1(13 to 25.4) using FP escutcheon. 14 x 14(4,3 x 4,3) 14(4.3) 16(61) 7.6(0,53) 16 x 16 (4,9 x 4,9) 16(4.9) 16 (61) 7.6 (0,53) Beamed Ceilings per NFPA 130, 13R or 13 installed in beams ½ to 1(13 to 25.4) using CCP. 8(2,4) 18x 18(5,5x5,5) 18(5,5) 19(72) 10.8(0,75) 1/2 to 1(13 to 25.4) using FP escutcheon. 20 x 20 (6,1 x 6, 1) 20(6,1) 22(83,3) 14.4(1,0) For Ceiling types refer to NFPA 13, 13R 01130 Nominal CCP Max. Max. Thread Orifice Assembly Ambient K Sprinkler Size Inch Pressure Temp. Temp . Factor Length (mm) psi (bar) Rating Inch (mm) °F ICC OFOC ½"NPT (R½) /16 (11) 175 (12) 135 57 1001 I 38 4.9(70.6) 2.25(57) 5. Model Fl Res 44 & 58 Recessed HSW/F2 F2 escutcheon, 1/2" (13mm) adjustment Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP (SIN R7618) Nominal I Max. I CCP Assembly Max. K Sprinkler Thread Orifice Pressure Temp. Rating Ambient Temp. Factor Length OF I °C OF I °C Size Inch (mm) psi (bar) Inch (mm) I 3/4" NPT /32" (13.5) 175 (12) 135 100 150 38 66 I 7.6(109) 2.25(57) (R3/4) Max. Coverage area Max. Spacing Ordinary Temp. Rating (155°FI8°C) Top of Deflector to Ceiling Minimum Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (11mm) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 21(79,5) 7.6 (0,53) Smooth Ceilings ½ to 1(13 to 25.4) using CCP. ½ to 1(13 to 25.4) using FP escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 21(79,5) 7.6 (0,53) 16 x 16 (4,9 x 4,9) 16(4.9) 21(79,5) 7.6 (0,53) Beamed Ceilings per NFPA 130, 13R or 13 installed in beams ½ to 1(13 to 25.4) using CCP. 8(2,4) 18 x 18 (5,5 x 5,5) 18(5, 22 (83,3) 8.4 (0,58) ½ to 1(13 to 25.4) using FP escutcheon. 20x20(6,1 x6,1) 20(6,1) 25(94,6) 10.8(0,74) For Ceiling types refer to NFPA 13, 13R or 13D Model Fl Res 44 & 58 HSW FACE OF FITTING TO - -1 1/4 MIN. I WALL DIMENSION CEILING TO -2 7/4" HOLE DIA. [31.8mm] "A I " [57.2mm] DIMENSION IMENSION7 DEFLECTOR 2 27/32" 0/A. [72.2mm] TURN COLLAR U;L TIGHT AGAINST SPRINKLER WRENCH BOSS. 1/2" (13mm] I35FCO6-D ADJUSTMENT Fl RES 58 & 44 HSW/F2 Fig. 5 Technical Data: F1 Res 44 HSW & HSW/F2 (SIN R3531) Thread Nominal Max. Sprinkler Max. Ambient K Sprinkler Size Orifice Pressure Temp. Rating Temp. Factor Length Inch (mm) psi (bar) IOC Inch (mm) 1°c OF ½" NPT 3/8" (10) 175(12) 155 68 100 38 4.4(63) 2.45(62) 175 79 150 66 Escutcheon, F2, Data: Face of Fitting Type Adjustment to wall Inch (mm) Inch (mm) F2 /2(13) /l6 - 11/6 (4.7-17.4) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F179°C) Top of Deflector to Ceiling Inch (mm) PSI (bar) Minimum Spacing Ft (m) Flow GPM (tfmin) Pressure PSI (bar) Flow GPM (Lfmin) Pressu re 12 x 12(3,6 x 3,6) 12(3.6) 12 (45,4) 7.5(0,52) 12 (45,4) 7.5(0,52) 4 to 6(100 to 152); ½ (13) recessed using F2 escutcheon 8(2,4) 14x 14(4,3x4,3) 14(4,3) 14(53,0) 10.2(0,71) 14 (53,0) 10.2(0,71) 16 X 16(4,9 X 4,9) 16(4,9) 16(60,6) 13.3(0,92) 16(60,6) 13.3(0,92) 16 x 18(4,9 x 5,5) 16(4,9) 18(68,1) 16.8(l.16) 18(68,1) 16.8 (1,16) 18x 18(5,5x5,5) 18(5,5) 19(72,0) 18.7(1,29) 19(72,0) 18.7(1,29) 16 x 20 (4,9 x 6, 1) 16(4,9) 23(87,1) 27.4(1,89) 23(87,1) 27.4(1,89) 12 x 12(3,6 x 3,6) 12(3,6) 14(53,0) 10.2 (0,71) 14(53,0) 10.2 (0,71) 6 to 12 (152 to 305); ½ (13) recessed using F2 escutcheon 14 x 14(4,3 x 4,3) 14(4.3) 16(60,6) 13.3(0,92) 16 (60,6) 13.3(0,92) 16 x 16(4,9 x 4,9) 16(4,9) 17(64,4) 15.0 (1,04) 17(64,4) 15.0(1,04) 16x 18(4,9x5,5) 16(4,9) 20(75,7) 20.7(1,43) 20(75,7) 20.7(1,43) 16 x 20(4,9 x 6,1) 16(4,9) 23 (87,1) 27.4(1,89) 23(87,1) 27.4 (1,89) For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: F1 Res 58 HSW & HSW/F2 (SIN R3533) Escutcheon, F2, Data: Nominal Max. Sprinkler Face of Fitting Max. Sprinkler Thread Orifice Ambient K Length Type Adjustment Pressure Temp. Rating to wall Size Inch psi (bar) Temp. Factor Inch Inch (mm) Inch (mm) _____ ___________ (mm) (mm) OF °C OF t38 /16 - ½" NPT 155 I 68 100 F2 '/2(13)/2" (13) 175(12)(R½) 175 I 79 150 5.8(83.5) 2.45(62) (4.7-17.4) Ordinary Temp. Rating Intermediate Temp. Rating Max. Coverage area Max. Spacing (1550F/68°C) (175°F/79°C) Top of Deflector to Minimum Ft x Ft (m x m) Ft (m) Ceiling Spacing Flow Pressure Flow Pressure GPM (L/min) PSI (bar) GPM (L/min) PSI (bar) Inch (mm) Ft (m) 12 x 12(3,6 x 3,6) 12(3.6) 16(60,6) 7.6(0,53) 16 (60,6) 7.6(0,53) 4t06(100to 152); 14x 14(4,3x4,3) 14(4,3) 18(68,2) 9.7 (0,69) 18 (68,2) 9.7 (0,69) 16 x 16(4,9 x 4,9) 16(4,9) 21(79,5) 13.2(0,91) 21(79,5) 13.2(0,91) ½(13) recessed using F2 escutcheon 16 x 18(4,9 x 5,5) 16(4,9) 25(94,7) 18.6(1,28) 25(94,7) 18.6(1,28) 8(2,4) 16 x 20(4,9 x 6,1) 16(4,9) 29(109,8) 25.0(1,73) 29(109,8) 25.0(1,73) 12 x 12(3,6 x 3,6) 12(3,6) 22(83,3) 14.4(1,0) 22(83,3) 14.4(1,0) 6 t 12(152t0305); ½ (13) recessed 14x 14(4,3x4,3) 14(4,3) 22(83,3) 14.4(1,0) 22(83,3) 14.4(1,0) 16 x 16(4,9 x 4,9) 16(4,9) 26 (98,4) 20.1 (1,39) 26(98,4) 20.1 (1,39) using F2 escutcheon 16x 18(4,9x5,5) 16(4,9) 31(117,4) 28.6(1,97) 31(117,4) 28.6(1,97) For Ceiling types refer to NFPA 13, 13R or 130 Model Fl Res 44 SWC * Not listed for corrosion resistance. Technical Data- F1 Rs 44 SWC 1IN R45%1 4 To 12 (101.60mm To I 1/4 (31.75mm] maximum 304.80mm] Tom Of Fi1b9 Woll Dimension PUSH ON COVER. THEN ON TO AOJUST UNTIL TIGHT AGAINST WALl. X 1/2 Reducer Recommended Well Hole 2 16- [6:] (8.%m]1__ 5116- [8 3 4.m] Die. TURN COLLAR UNTIL IICHT AGAiNST SPRINKLER 21/32 WRENCH 805& 112- [1 Adjustment Fl RES 44 SWC Fig. 6 a Nominal Max. Cover Max. Sprinkler Thread Orifice Pressure Temp. Ambient K Length Size Inch (mm) psi (bar) Rating Temp. Factor Inch (mm) ½" NPT (R1/) /8" (10) 175(12) 135 57 100 I 38 4.4(63) 2.45(62) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°c) Top of Deflector to Ceiling Inch (mm) PSI (bar) Minimum Spacing Ft (m) Flow GPM (L/min) Pressure 12x 12(3,6x3,6) 12(3,6) 13(49,2) 8,7(0,60) 4 to 6 ( 100 to 152); ½(13) recessed using F2 escutcheon 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 14(53,0) 10.2 (0,71) 16 x 16(4,9 x 4,9) 16(4,9) 17(64,3) 15.0(1.1) 16 x 18(4,9 x 5,5) 16(4,9) 19 (71,8) 18.7 (1,13) 16 x 20(4,9 x 6,1) 16(4,9) 23 (87,1) 27.4 (1,89) 12x 12(3,6x3,6) 12(3,6) 14(52,9) 10.2(0,71) 6 t 12(152t0305); ½ (13) recessed using F2 escutcheon 14x 14(4,3x4,3) 14(4,3) 15(56,7) 11.7(0,81) 16 x 16(4,9 x 4,9) 16(4,9) 18(68,1) 16.8 (1,16) 16 x 18(4,9 x 5,5) 16(4,9) 20(75,6) 20.7 (1,43) For Ceiling types refer to NFPA 13, 13R or 13D 91 Model KRes58 HSWX (Link) Technical Data: Fl Res 58 HSWX (SIN RA3533) Thread Nominal Max. Sprinkler Max. Ambient K Sprinkler Sprinkler Size Orifice Pressure Temp. Rating _____________ Temp. ___________ Factor Length Identification Inch (mm) psi (bar) Inch (mm) OFJOC Number (SIN) OF 1°c Bulb ½" NPT 1/2" (13) 175 (12) 155 68 (R½) 100 38 5.8(83.5) 1 2.45(62) RA3533 Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F1680C) Intermediate Temp. Rating (1 75-17/790C) Top of Deflector to ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM (Lfmin) Pressure PSI (bar) Flow GPM (Llmin) Pressure PSI (bar) 18 x 20 (5,5 x 6, 1) 18(5,5) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 4t06(100to 152); ½ (13) recessed using F2 escutcheon 8(2.4) 20 x 20 (6,1 x 6, 1) 20(6,1) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 16 x 22(4,9 x 6,7) 16(4,9) 33 (125) 32.4(2,23) 33(125) 32.4(2,23) 16 x 24(4,9 x 7,3) 16(4,9) 38(144) 42.9(2,96) 38(144) 42.9(2,96) 14 x 26(4,3 x 7,9) 14(4.3) 42 (160) 52.4(3,75) 42(160) 52.4(3,75) 18 x 20(5,5 x 6,1) 18(5,5) 35(133) 36.4(2,5) 35(133) 36.4 (2,5) 6 to 12 (152 to 305): 1/2(13) recessed using F2 escutcheon 16 x 22 (4,9 x 6,7) 16(4,9) 38 (144) 42.9 (2,96) 38 (144) 42.9 (2,96) 16 x 24(4,9 x 7,3) 16(4.9) 42 (160) 52.4(3,6) 42(160) 52.4(3,6) 14 x 26(4,3 x 7,9) 14(4,3) 46(174) 62.9(4,34) 46(174) 62.9 (4.34)1 For Ceiling types refer to NFPA 13, 13R or 13D Model Fl Res 58 HSWX (Bulb) 1/8 ' I 77/76" MIN. [3'8mm] I i H i CEILING TO I (3.2mm] DEFLECTOR I DIMENSION _ I 2 27/32" OIA. [72.2 m] 7/2" [13mm] ADJUSTMENT FACE OF FITTING TO WALL DIMENSION 2 7/4" HOLE OIA. [57.2mm] X 1/2" REDUCER I 75/76" DIA.I/ 4 (49.2mm] --'4- TURN COLLAR UNTIL -- TIGHT AGAINST SPRINKLER WRENCH BOSS. 135FG08 —H Fl RES 58 HSWX Fig. 7 de Technical Data: KRes58 HSWX (RA3593) Thread Nominal Max. Max. Ambient K Sprinkler Sprinkler Size Orifice Pressure Temp. Factor Length Identification Inch (mm) psi (bar) Inch (mm) Number (SIN) OF Link Y2" NPT 1/2" (13) 175(12) 100 C 38 5.8(83.5) 2.45(62) RA3593 Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (165°F174°C) Top of Deflector to ceiling Inch (mm) PSI (bar) Minimum Spacing Ft (m) Flow GPM (Lfmin) Pressure 18 x 20(5,5 x 6,1) 18(5,5) 29(109) 25(1,72) 4t06(100to 152); 1/2 (13) recessed using F2 escutcheon 8(2.4) 20 x 20 (6,1 x 6, 1) 20(6,1) 30(114) 26.8(1,85) 16 x 22(4,9 x 7,3) 16(4,9) 33 (125) 32.4 (2,23) 16 x 24(4,9 x 7,3) 16(4,9) 38(144) 42.9(2,96) 14 x 26(4,3 x 7,9) 14(4,3) 42 (160) 52.4 (3,75) 18 x 20(5,5 x 6,1) 18(5,5) 35(133) 36.4 (2,5) 6 to 12 (152 to 305); ½(13) Recessed using F2 escutcheon 16 x 22(4,9 x 6,7) 16(4,9) 38(144) 42.9 (2,96) 16 x 24(4,9 x 7,3) 16(4,9) 42 (160) 52.4(3,6) 14 x 26 (4,3 x 7,9) 14(4,3) 46 (174) 62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 13D Maintenance Model Fl Res 30, 49, Fl Res 58, Fl Res 76 and El Res 44 Sprinklers should be inspected and the sprinkler sys- tem maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Am- monia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Model Fl Res 30, 49 & 58 Pendent Sprinkler Specifications Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pendent sprin- klers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guide- lines and the applicable installation standard. Deflector- to-ceiling distance listing shall be 1" to 8" maximum, only for F1 Res 49. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Wa- "DuPont Registered Trademark 10. ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 and 5.8. Standard finish: [Bronze] [Chrome- plated] [White Polyester] [Special finish- specify]. Resi- dential pendent sprinklers shall be Reliable Model El Res 30,49 & 58, SIN R351 1, R3516 & R3513 (Bulletin 135). Model Fl Res 49 & 58 Recessed Pendent/Fl, Model Fl Res 30, 49 & 58 Recessed Pendent/ F2, Model Fl Res 30,49 & 58 Recessed Pendent/ FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential recessed pen- dent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's in- stallation guidelines and the applicable installation stan- dard. Deflector-to-ceiling distance listing shall be 1" to 8" maximum, only for F1 Res 49. Sprinkler frame and deflec- tor shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nomi- nal K-factor of 3.0, 4.9 & 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish— spec- ify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½' adjustment (Model F2)] [with 3%" adjustment (Model Fl)] [of push-on and thread off design with ½" adjustment (Model FP)]. Standard fin- ish shall be [brass][bright chrome] [white painted]. Resi- dential recessed pendent sprinklers shall be Reliable [Model Fl Res 30, 49 & 58 Recessed Pendent/F1] [Model Fl Res 30, 49 & 58 Recessed Pendent/F2] [Model Fl Res 30,49 & 58 Recessed Pendent/FP] SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 30, 49 & 58 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design den- sity of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be in- stalled in conformance with the manufacturer's installa- tion guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal as- sembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate tem- perature rating shall be 135°F (570C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color— specify]. ]. Concealed pendent sprinklers shall be Reliable Model Fl Res 30, 49 & 58 CCP, SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 44, Fl Res 58 Horizontal Sidewall, Fl Res 58 HSWX & KRes58 HSWX Residential Sprinkler Specifications Sprinklers shall be [cULus Listed] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon* coated Bel- leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (79°C)]. The solder element (Link) version, the water seal consist of a cap with a bellville spring washer and a temperature rating of 165°F (740C). The recessed assembly forthe HSWX (Bulb & Link) should be a steel two pieces escutcheon with 1/2' adjustment (Model F2) standard finish should be Bright Chrome and white paint- ed. The Fl Res 58 HSW is also available with low lead frame. Fl Res 58 HSW and HSWX sprinklers shall have a nominal K Factor of 5.8 and Fl Res 44 a nominal K factor of 4.4. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish— specify]. Residential horizontal sidewall sprinklers shall be Reliable Model Fl Res 44, Fl Res 58, Fl Res 58 HSWX & Model KRes58 HSWX, SIN R3531, RA3533 & RA3593 (Bulletin 135). Model Fl Res 44 Recessed Horizontal Sidewall Sprinkler Use description for the Model Fl Res 44 horizontal side- wall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish— specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model Fl Res 44/F2, SIN R3531 (Bulletin 135). Model Fl Res 76 Pendent Sprinklers shall be [cULus Listed] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3%" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- cial finish— specify]. Residential pendent sprinklers shall be Reliable Model Fl Res 76, SIN R7618 (Bulletin 135). *DuPont Registered Trademark Model Fl Res 76 Recessed Pendent/Fl, Model Fl Res 76 Recessed Pendent/F2, Model Fl Res 76 Recessed Pendent/FP Sprinklers shall be [cULus Listed] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturers technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Water seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and hav- ing a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- cial finish— specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½" adjust- ment (Model F2)] [with 3%" adjustment (Model Fl)] [of push-on and thread off design with 1/2" adjustment (Mod- el FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model Fl Res 76 Recessed Pendent! Fl] [Model Fl Res 76 Recessed Pendent/F2] [Model Fl Res 76 Recessed Pendent/FP] SIN R7618 (Bulletin 135). Model Fl Res 76 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3%" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (680C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate tem- perature rating shall be 135°F (570C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color— specify]. ]. Concealed pendent sprinklers shall be Reliable Model Fl Res 76 CCP, SIN R7618 (Bulletin 135). Finishes (1) Standard Finishes Sprinkler F1, FP F2, Cover Plates Escutcheons Bronze Brass White Painted Chrome Plated Bright Chrome Plated Chrome White and Black White Painted Polyester (2) Coated Special Application Finishes Sprinkler Fl, F2, FP Escutcheons Electroless Nickel PTFE(Teflon®))2) Electroless Nickel PTFE (Teflon®) Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Chrome Dull Chrome Dull Other finishes and colors are available on special order. Consult factory for details. cULus listed Corrosion Resistant Note: Paint or any other coating applied over the factory finish will void all approvals and warranties. Ordering Information Specify: Sprinkler Model Sprinkler Type Temperature Rating Sprinkler Finish Escutcheon Finish Cover Plate Finish *DuPont Registered Trademark The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address 0 Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 06/15 P/N 9999970235 -'--: - 1 1 Model Fl FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Spray Pendent Model F1FR42, F1FRXLH & FlFR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model Fl FR40 Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FR40, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Spray Pendent Model Fl FR56LL & Fl FR42LL NSF Certified Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model F1FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kler. Underwriters Laboratories Inc. and Certified for Canada (cULus). FM Approvals (FM) Loss Prevention Certification Board (LPCB) VdS Schadenverhutung GmbH (VdS) NSF Certified to NSF/ANSi Standard 61 Annex C (NSF) EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-4025 1 (RA 1425), 0786-CPD-40252 (RA 1475) (EC) UL Listing Category Sprinklers, Automatic & Open (VNlV) Quick Response Sprinkler Bulletin 014 Rev. N Quick Response Bulb Sprinklers Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed PendentjF1/F2 Recessed Concealed Recessed Horizontal Sidewall Pendent Pendent/FP XLH Upright XLH Pendent Pendent F1/F2 Product Description Reliable Model F1FR series sprinklers are quick-response automatic sprin- klers with a glass bulb thermal element. Model Fl FR series sprinklers are Stan- dard Spray sprinklers, with the excep- tion of the Model El FR56 Conventional XLH Recessed sprinkler which is an Old-style/Conven- Pendent FP tional sprinkler. The Model F1FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrat- ed response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Park Drive, Elmsford, New York 10523 Reliable Automatic Sprinkler Co., Inc., 103 Fairview C 0 CD 012 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model F1FR Series sprinklers provide a wide range of op- tions where quick-response, glass bulb sprinklers are used: Pendent, recessed pendent, upright, horizontal side- wall, and vertical sidewall deflectors K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model Fl FR series sprinkler configurations. Model F1FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model Fl, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model F1FR series sprinkler. Model Fl and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model F1FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. 2. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model Fl FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model Fl FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model F1FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers have a factory-installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model RC1 wrench is used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the spnkler/cup assembly Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model El FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector/ Orientation Nominal N i S Sprinkler Height Installation Wrench SIN Approvals Listings and Approval Notes US Metric inches mm inches mm F1FR28 2.8 40 3/8 10 Pendent 2.25 57 D RA1411 cULus 2 Recessed Pendent 2.25 57 GFR2 RA14111 cULus 2 Upright 2.25 57 D RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 D RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS F1FR42 4.2 60 7/16 10 Pendent 2.25 57 D RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA14131 cULus 2 Upright 2.25 57 D RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 D RA1410 cULus, NSF Recessed Pendent 2.25 57 GFR2 RA1410 cULus, NSF F1FRXLH (F1FR42 with Pintle) 4.2 60 7/16 10 Pendent 2.25 57 0 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA14131 cULus 2 Upright 2.25 57 D RA1423 cULus 1,2 F1FR56 5.6 80 1/2 15 Pendent 2.25 57 D RA1414 cULus, FM, I LPCB,VdS,EC 1,2,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus FM , , LPCB, VdS, EC 1,2,3,4 Concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 D RA1425 cULus, FM, LPCB, VdS, EC 1,2,3,4 "Conventional 2.25 57 (Pendent or Upright)" D RA1475 LPCB, VdS, EC 4 F1FR56LL 5.6 80 1/2 15 Pendent 2.25 57 0 RA1415 cULus, NSF 1 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, NSF Concealed Pendent 2.25 57 RC1 RA1414 cULus, NSF 6 F1FR56 5.6 80 1/2 15 Horizontal Sidewall 2.63 67 D RA1435 cULus, FM 1,2,3,7 Recessed Horizontal Sidewall 2.63 67 GFR2 RA1435 cULus, FM 8 F1FR56 5.6 80 1/2 ______ 15 Vertical Sidewall (Pendent or Upright) 2.25 57 D RA1485 cULus, FM, LPCB 1,2,3,9 " cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. Available with FM approved Polyester coating in black or white. Available with LPCB and VdS approved Polyester coating. VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8,0 mm) of adjustment. cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the F1FR56 Hori- zontal Sidewall sprinkler is for Light Hazard occupancies only. (8) cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. () The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. Minimum to maximum deflector to ceil- ing distance shall be 4 inches to 12 inches (102mm to 305mm). LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Model Deflector/ Orientation Ordinary Temp. Classification 100°F (38°C) Max. Ambient Temp. Intermediate Temp. Classification 150°F (65°C) Max. Ambient Temp. High Temp. Classification 225°F (107°C) Max. Ambient Temp. 135°F (57°C) Temp. Rating I 155°F (68°C) I Temp. Rating 175°F (79°C) Temp. Rating I 200°F (93°C) I Temp. Rating 286°F (141°C) Temp. Rating Orange Bulb I Red Bulb Yellow Bulb I Green Bulb Blue Bulb Pendent cULus Fl FR28 Recessed Pendent cULus - Upright cULus F1FR4O Pendent VdS Recessed Pendent VdS I -- Pendent cULus Fl FR42 Recessed Pendent cULus I -- __________ Upright cULus F1FR42LL Pendent -- I cULus, NSF -- Recessed Pendent -- I I cULus, NSF -- Pendent cULus Fl FRXLH Recessed Pendent cULus -- __________ Upright cULus Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC I -- F1 FR56 Concealed Pendent* cULus I cULus,VdS,EC cULus I -- Upright cULus, FM, LPCB, VdS, EC "Conventional (Pendent or Upright)" LPCB, VdS, EC Pendent -- I cULus, NSF I -- F1FR56LL Recessed Pendent -- cULus, NSF -- _________ Concealed Pendent* -- I cULus, NSF I -- Horizontal Sidewall cULus, FM Fl FR56 Recessed Horizontal Sidewall cULus, FM I -- Fl FR56 Vertical Sidewall (Pen- dent _or_Upright) cULus, FM, LPCB * Model Fl FR56 Concealed Pendent and Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Model Deflector! Orientation Listed and Approved Recessed Escutcheons SIN Model Fl (Fig. 1 & 3) 3/4-inch (19mm) adjustment Model F2 (Fig. 1 & 3) 1/2-inch (12.7mm) adjustment Model FP (Fig. 2) 1/2-inch (12.7mm) adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA 1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, EC cULus, FM, LPCB, VdS, EC cULus, VdS, EC RA1414 F1FR56LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 4 AT MAXIMUM RECESS = 7/8"[22.2mm] [3.2mm] 1A T MINIMUM RECESS = 1-5/8"[4 1.3mm] r F2 ESCUTCHEON I AT MAXIMUM RECESS = 1-1/8"[28.6mm] AT MINIMUM RECESS 1-5/8 "[4 1.3mm] A F! ESCUTCHEON 1" X 1/2" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/8 "[9.5mm] F2 ESCUTCHEON TAT MAXIMUM RECESS = 3/4'[19mm] 77777-71 AT MINIMUM RECESS = 3/8"[9.5mm] TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS ----\ F! ESCUTCHEO!/J_ 3/4"[l9mm] ADJUSTMENT F2 ESCUTCHEON 1/2[12.7mm] ADJUSTMENT 2 1/4" HO/I' 0/A. [5 7.2mm] - ______ I 15/16" 0/A [49.2mm] r 1 (1 2 27/32" 0/A. [72.2mm] Hg. 1 Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model Fl or F2 escutcheon L—_—_—__--=--1 t--1 I - ------I 7" ,\' 7/2" REDUCER 2 5/8" 0/A. [66.7mm] - ___________ HOLE IN CEILING / / 2 5/16" 0/A. [58.7mm] CUP L CEILING FACE OF FITTING 03SVE1 TO FACE OF CEILING DIMENSION L RECESS = AT MINIMUM RECESS = 1 "[25.4mm] Y"[12.7mm] J I AT MAXIMUM RECESS 9/16"[14.jmmJ ADJUSTMENT 3 1/4" 0/A, [82.6mm] Fig. 2 Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model FP escutcheon I HOLE IN CEILING 1 1/2" MAX. FACE OF FITTING _..HTO FACE OF CEILING /.4 DIMENSION FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/8"[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4"[19mm] AT MINIMUM RECESS = 3/8"[9.5mm] 2 1/4" HOLE 0/A. [5 7.2mm] Fl ESCUTCHEON (L_tl AT IJAWUAflIA nrr'rc'c' - 4 7 /o"f,.. n......7 .'lI IVItiAlIVl(JIVI 1-010 L iT. (fImflJ AT MINIMUM RECESS = 2-1/16 "[52.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8"[41.3mm] AT MINIMUM RECESS = 2-1/16 "[52.4mm] [3.2mm] 1" X 1/2" REDUCER r_r r 1 15/16" 0/A LJ [49.2mm] till lilt A— J LJL 2 27/32" DIA. [72.2mm] T (1) 4"-12" [101.6mm-304.8mm] CEILING TO DEFLECTOR TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER Fl ESCUTCHEON WRENCH BOSS. ADJUSTMENT H F2 ESCUTCHEON 1/2"[12.7mm] ADJUSTMENT OS3FO3E RECESSED HSW w/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [10 1.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 Model F1FR56 Recessed Horizontal Sidewall sprinkler with Model Fl or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW 2 5/16" DIA - CUP -.- rH / / / '1' / / A __J/ ': CEILING 1/2" MAX. COVER ADJUSTMENT COVER PLATE ASSEMBLY . 5/16" DIA SPRINKLER CONCEALED, 1/2" ADJUSTMENT 017VGO1A Fig. 4 Model Fl FR56IF1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model CCP cover plate 1" x TEE 1/2" REDUCING OR ELBOW -EfI' -.-+ 2 5/16" 0/A CUP - CElL INC 5/16" MAX. COVER ADJUSTMENT COVER PLATE ASSEMBLY SPRINKLER 2 5/8" 0/A. HOLE IN CEILING 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 3/4" CONCEALED, 5/16" ADJUSTMENT O 7FGO2A Fig. 5- Model Fl FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch (8.0mm) adjustment - Model CCP cover plate Maintenance The Model Fl FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate1 Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated (41(5)(6) White Painted Special Application Finishes Sprinkler Escutcheon Cover plate01 Electroless Nickel FIFE(7) Electroless Nickel FIFE Bright Brass Bright Brass(') Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint(2X6) Black Paint Off White Off White (2X6) Off White Satin Chrome Chrome Dull Chrome Dull Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSw), RA1485(VSw), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. > LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. >7> cULus listed Corrosion Resistant 7 Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with FIFE Adhesive Tape Bulb: Glass Ordering Information Specify: Sprinkler Model: [F1FR28][F1FR40][F1FR42] [Fl FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent][Upright][Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] Sprinkler Temperature Rating: [135°F (570C)][155°F (68°C)][ 175°F (790C)][200°F (930C)][286°F (1410C)] Sprinkler Finish Escutcheon Model: [Fl ][F2][FP] Escutcheon Finish (where applicable) Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.0mm) adjustment] Cover plate Temperature Rating: [135°F (57C) for use with Ordinary Temperature sprinklers][ 165°F (74°C) for use with Intermediate Temperature sprinklers] Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. 1921111111 Recycled ® (800) 431-1588 Sales Offices Paper (914) 829-2042 Corporate Offices C (800) 848-6051 Sales Fax Revision lines indicate updated or new data. Reliabl www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 12/15 P/N 99999703w