Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DWG 455-4L; PD 07-09; VIASAT BUILDING 6; 01-09
GENERAL NOTES RECYCLED WATER NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE CARLSBAD MUNICIPAL WATER DISTRICT'S "CARLSBAD RECLAMATION RULES AND REGULATIONS FOR CONSTRUCTION OF RECYCLED WATER MAINS" DA TED OCTOBER, 199J. 2. DRINKING FOUNTAINS SHALL BE PROTECTED FROM SPRAY FROM RECYCLED WATER. BEST MANAGEMENT PRACTICES SHALL BE USED TO MINIMIZE RECYCLED WATER ENCROACHMENT ON PUBLIC FACILITIES SUCH AS PICNIC TABLES, BBQ'S, PLAYGROUNDS, SAND TOT LOTS, ETC. J. NO PONDING, RUN-OFF OR 0\/fR-SPRAY IS PERMITTED. 4. HOSE BIBS ARE STRICTLY PROHIBITED. 5. ON-SIT£ CROSS-CONNECTIONS BETWEEN RECYCLED WATER LINES AND POTABLE WATER LINES IS STRICTLY PROHIBITED. 6. NO SUBSTITUTION OF PIPE MATERIALS WILL BE ALLOWE'D WITHOUT PRIOR APPROVAL OF THE CITY OF CARLSBAD MUNICIPAL WA T£R DISTRICT. 7. ALL ON-SIT£ PIPES SHALL HA VE WARNING TAPE PER CARLSBAD MUNICIPAL WATER DISTRICT'S RULES AND REGULATIONS. * 8. THE IRRIGATION SYSTEMS SHALL RUN BETWE:EN THE HOURS OF 10:00 P.M. AND 6:00 A.M. THE FOLLOWING MORNING (SPOT IRRIGATION COULD BE DONE AT A DIFFERENT TIME) WITH QUALIFIED SUPERVISION PERSONNEL ON SITE. 9. PROVIDE A MINIMUM OF AT LEAST 18 INCHES OF COVER OVER ALL WIRING AND PIPING. 10. NON-DESIGNATED USE AREAS SHALL 8£ PROTECTED FROM CONTACT FROM RECYCLED WATER, WHETHER BY WINDBLOWN SPRAY OR BY DIRECT APPLICATION, THROUGH /RR/GA TION OR OTHER APPROVED USE. LACK OF PROTECTION, WHETHER BY DESIGN, CONSTRUCTION PRACTICE OR SYSTEM OPERATION, IS STRICTL y PROHIBITED. 11. CONTRACTOR SHALL ADJUST HEADS TO PREVENT OVER-SPRAYING ON ALL SIDEWALKS, STREET, AND PR/VAT£ LOTS. 12. RECYCLED WATER QUICK COUPLING VALVES SHALL BE OF A TYPE DESIGNED FOR THE USE ON RECYCLED WATER DISTRIBUTION SYSTEMS (SPIKES NOT INTERCHANGEABLE WITH POTABLE WATER QUICK COUPLER SPIKES PER CARLSBAD MUNICIPAL WATER DISTRICT'S RULES AND REGULATIONS. 1 J. METERS SHALL BE SIZED BY THE CITY OF CARLSBAD MUNICIPAL WATER DISTRICT. 14. ALL /RR/GA TION PIPES SHALL 8£ STENCILED Wl1H 1HE WARNING, "NON-POTABLE OR RECYCLED WATER", COLOR-CODED (PURPLE) AND LAID WITH WARNING TAPE AND STENCILING ORIENTED TOWARD THE TOP OF THE TRENCH PER THE CARLSBAD MUNICIPAL DISTRICT'S RULES AND REGULATIONS 15. ALL POTABLE WATER AND RECYCLED WATER PIPING SHALL BE INSTALLED WITH THE STENCILING ORIENTED TOWARD THE TOP OF THE TRENCH. 16. WHEN A POTABLE WATER LINE AND RECYCLED WATER LINE CROSS, 1HE RECYCLED LINE SHALL BE INSTALLED WITHIN A PROTECTIVE SLEEVE. THE SLEEVE SHALL EXTEND 10 FEET FROM EACH SIDE, FROM THE CENTER LINE OF POTABLE LINE, FOR A TOTAL OF 20 FEET. 17. A 10 FOOT HORIZONTAL SEPARATION BETWE'EN POTABLE WATER AND RECYCLED WATER MAINS MUST BE MAINTAINED AT ALL TIMES. THE POTABLE LINE MUST BE INSTALLED ABOVE THE RECYCLED LINE. 18. A MINIMUM OF 12 INCHES OF VERTICAL SEPARATION BETWE'EN UTILITIES MUST BE MAINTAINED AT ALL TIME:S. * 19. DEVELOPER/CONTRACTOR SHALL CONDUCT A CROSS-CONNECTION TEST AND COVERAGE TEST AS DIRECTED BY THE CARLSBAD MUNICIPAL WATER DISTRICT ENGINEER OR THE SAN DIEGO COUNTY DEPARTMENT OF HEALTH SERVICES PRIOR TO ANY USE OF RECLAIMED WATER. 20. QUICK COUPLING VALVES USED IN RECYCLED WATER SYSTEMS SHALL CONFORM TO THE FOLLOWING: A. RECYCLED WATER -QUICK COUPLING VALVES USED IN RECYCLED WATER SYSTEMS SHALL HAVE ACME TYPE 1HREADS AND PURPLE COLORED LOCKING COVERS PERMANENTLY ATTACHED TO THE VALVE. QUICK COUPLING VALVES SHALL BE NELSON NO. 7645, HUNTER NO. HVIOOA-RL-NP OR APPROVED EQUAL (SPIKES SHALL NOT BE INTERCHANGEABLE WITH POTABLE WATER QUICK COUPLING SPIKES. 21. AN ANNUAL CROSS CONNECTION INSPECTION WILL BE DONE BY EITHER CARLSBAD MUNICIPAL WATER DISTRICT OR SAN DIEGO COUNTY DEPARTMENT OF HEAL TH SERVICES COPIES OF INSPECTION REPORTS WILL BE FORWARDED TO THE NON-INSPECTING PARTY. *22. DEVELOPER SHALL SHOW THE LOCATION OF R.C. SIGNS "DO NOT DRINK" ON THESE PLANS. * 2J. AN ON-SITE USER/SUPERVISOR SHALL 8£ DESIGNATED IN WRITTNG. THIS INDIVIDUAL * SHALL BE FAMILIAR WITH PLUMBING SYSTEMS WITHIN 1HE PROPERTY, WITH THE BASIC CONCEPTS OF BACKFLOW/CROSS-CONNECTION PROTECTION, AND THE SPECIFIC REQUIREMEl;>ITS OF A RECYCLED WATER SYSTEM. COPIES OF 1HE DESIGNATION, Wl1H CONTACT PHONE NUMBERS SHALL BE PROVIDED TO THE SAN DIEGO COUNTY DEPARTMENT OF HEAL TH SERVICES AND CARLSBAD MUNICIPAL WATER DISTRICT. IN CASE OF EMERGENCY CONTACT: MAINTENANCE SUPERVISOR CARL HAt,lfR AT (760) 455 2703 OR AFTER HOURS CONTACT: MAINTENANCE SUPERVISOR CARL HAMER AT (760) 455 2703 24. SHOW ALL PUBLIC & PRIVATE POTABLE WATER MAINS ON IMPROVEMENT PLANS. ITEMS NOS. 8, 19 & 2J SHALL BE REQUIRED JUST PRIOR TO 1HE ACTUAL USE OF RECYCLED WATER. ITEM NO. 22 THE SIGNAGE: PLAN SHALL BE PART OF THIS J.P. BUT THE ACTUAL SIGNS & TAGS WILL BE INSTALLED JUST PRIOR TO ACTUAL USE OF R.C. WATER. 24. ALL IRRIGATION BACKFLOW PREVENIERS SHALL 8£ TESTED BY A CERTIFIED TESTER AND RESULTS MUST BE G1VEN TO THC CITY AND TH£ CARLSBAD MUNICIPAL WATER DISTRICT. PIP£ 8£TWE:EN TH£ ME:TER AHD BACKFLOW PR£VENT£R SHALL 8£ "SCHEDULE: K HARD COPPE:R". APPROVED CON111ACT IIAQ(Fl.OW TESTERS CAN BE: FOUND ON THE CITY v.EBSITE AT WWW Cf CARLS6NLP4 IJ.!hOfROC.HlML?f'ID-340 In Order to Con....,. Wot.-•.. 12" X 36" SIZE (N.T.S.) WARNING RE YCLED WATER DO NOT DRINK R CYCLED WATER FTER CONTACTING S DESPUES DE USAR 1" BLACK LETTERS 2" BLAa< LETTERS RECYCLED WATER _ IN USE !!! f DD NOT DRINK NO TOME L AGUA -HNmS M1DI COIT-. lAl{SE SUS M/IIIOS 0E9PUES Ill - 18" X 18" SIZE SIGNAGE NOTES TH£ FOLLOWING GUIDELINES FOR TH£ USE OF RECYCLE:D WATER ARE TO BE PERMANENTLY POSTED INSIDE: THE DOOR OF EACH CON111QU.ER M/£R£ THEY ARE EASILY VISIBLE. PLACE ON 8-1/2" X 11" SIZE:D SIGN. COLOR: PURPLE BACKGROUND WITH BU.CK LETTERING. 1. GUIDELJNES FOR RECYCLED WA JE"R USC A. IRRIGATE BETv.EEN THE HOURS OF 10:00 P.M. AND 6:00 A.M. ONLY. WATERING OUTSIDE THIS TIM£ FRAM£ MUST BE DONE MANUALLY WITH QUAUF1£D SUPERVISORY PERSONNEL ON-SITE. NO SYSTEM SHALL AT ANY TIME BE LEFT UNATTENDED DURING USE OUTSIDE THE NORMAL SCHEDULE. B. IRRIGATE IN A MANNER THAT WILL MINIMIZE RUN-OFF, POOLING, AND PONDING. THE APPL/CATION RA TE SHALL NOT EXCEED THE INFILTRATION RA TE OF THE SOIL. TIMERS MUST BE ADJUSTED SO AS TO BE COi.iPA TIBLE WITH THE LOv.EST SOIL INFILTRATION RA TE PRESENT. THIS PROCEDURE MAY BE FACILITATED BY THE EffiCIENT SCHEDULING OF THE AU TOMA TIC CONTROL CLOCKS, (I.E., EMPLOYING THE REPEAT FUNCTION TO BREAK UP THE TOTAL /RR/GA TION TIME INTO CYCLES THAT WILL PROMOTE MAXIMUM SOIL ABSORPTION). C. ADJUST SPRAY HE:ADS TO ELIMINATE OVERSPRAY ONTO AREAS NOT UNDER TH£ CONTROL OF THE CUSTOMER. FOR EXAMPLE, POOL DECKS, PR/VA TE PA nos ANO LOTS, AND STREETS AND SIDEWALKS. D. MONITOR AND MAINTAIN THE SYSTEM TO MINIMIZE EQUIPMENT AND MATERIAL FA/LURE. BROKEN SPRINKLER HEADS, LEAKS, UNRELIABLE VALVES, £TC., SHOULD BE REPAIRED AS SOON AS THEY BECOME APPARENT. E. EDUCATE ALL MAINTENANCE PERSONNEL ON A CONTINUOUS BASIS OF THE PRESE:NCE OF RECYCLED WATER. PERSONNEL MUST BE INFORMED THAT RECYCLED WATER IS MEANT FOR /RR/GA TION PURPOSES ONLY, AND IS NOT APPROVE:D FOR DRINKING PURPOSES, HAND WASHING, CLE:ANING OF TOOLS, ETC. GJVEN THE HIGH TURNOVER RA TE OF EMPLOYEES IN THE LANDSCAPE INDUSTRY, IT IS IMPORTANT THIS INFORMATION 8£ DISSEMINATED ON AN ALMOST DAILY BASIS. IT IS YOU, THE LANDSCAPE CONTRACTOR W/-10 IS RESPONSIBLE FOR EDUCATING £ACH AND EVERY ON£ OF YOUR EMPLOYEES. F. OBTAIN PRIOR APPROVAL OF ALL PROPOSED CHANGES AND MODIFICATIONS TO ANY PRIVATE ON-SITE FACILITIES. SUCH CHANGES MUST BE SUBMITTED TO,AND APPROVED BY, THE DISTRICT ENGJNEERING OFFICE AND DESIGNED IN ACCORDANCE WITH DISTRICT STANDARDS. 1. ALL RECYCLED WATER SPRINKLER CONTROL VALVES SHALL BE TAGGE:D WITH IDENTIFICATION TAGS. A. TAGS SHALL 8£ v.EA THERPROOF PLASTIC, J"x 4", PURPLE IN COLOR, WITH TH£ WORDS "WARNING RECLAIMED WATER -DO NOT DRINK" IMPRINTED ON ONE SIDE, AND "NO TOME EL AGUA• IMPRINTED ON THE OTHER SIDE. IMPRINTING SHALL BE PERMANENT AND BLACK IN COLOR. USE TAGS AS MANUFACTURED BY T. CHRISTY ENTERPRISES OR APPROVED EQUAL. B. ON£ TAG SHALL BE ATTACHED TO EACH VALVE AS FOLLOWS: 1. ATTACH TO VALVE STEM DIRECTLY OR WITH PLASTIC TIE-WRAP OR 2. ATTACH TO SOLENOID IIIRE DIRECTLY OR WITH PLASTIC TIE-Wl?AP J}fi J. ATTACH TO VALVE COVER WITH EXISTING VALVE COVER BOLT. 2. ALL SPRINKLER HEADS SHALL BE IDENTIFIED AS RECYCLED WATER SPRINKLER HE:ADS. G. EACH AUTOMATIC CONTROLLER AND ,rs ASSOCIATED EQUIPMENT SHALL BE IDENTIFIED WIJH A SIGN BEARING THE WORDS "R£CYCL.£D WATER USED FOR IRRIGATION" IN ENGLISH AND SPANISH, WITH BLACK LETTERS 1" HIGH ON A PURPLE BACKROUND. TH£ SIGN SHALL BE PLACED SO THAT IT CAN 8£ READILY SEEN BY ANY OPE:RA TIONS PERSONNEL UTILIZING THE EQUIPMENT. DECLARATION OF RESPONSIBLE CHARGE:: I HEREBY DECLARE THAT I AM LANDSCAPE ARCHITECT OF WORK FOR 1HIS PROJECT, THAT I HA VE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THIS PROJECT AS DEFINED IN SECTION 670J OF THE BUSINESS AND PROFESSIONS CODE AND THAT TH£ DESIGN IS CONSISTENT WJTH CURRE:NT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD AND SAN DIEGO COUNTY DEPARTMENT OF HEALTH SERVICES IS CONFINED TO A REVIEW ONLY AND DOES NOT RELJEVE ME, AS LANDSCAPE ARCHITECT OF WORK, OF MY RESPONSIBILITTES FOR PROJECT DESIGN. 11-IESE PLANS HAVE BEEN PREPARED IN SUBSTAN11AL CONFORMANCE Willi Il/E APPROVED LANDSCAPE CQNCfPT Pl AN WATER CQNSfRVA110N PLAN FIRE PRQJECIZQN PLAN AND ALL CONDITTONS OF APPROVAL RfLATFD TO LANDSCAPING FIRM NAMES & ADDRESSES: .'b MW PELTZ AND ASSOC/A TES 14J SOUTH CEDROS AVENUE, SUITE 8-104 SOLANA BEACH CA 92075 PHONE NO(S): ( ~) .,,48.,.li..::.i.OB.....,BB._ ____ _ REGISTRATION NO(S): 2010 EXPIRATION DATES: ___ _.2~0.,1~0 ___ _ INSPECTION PROCEDURES 1. CITY CONSTRUCTION INSPECTION SHALL INCLUDE: 2. A. LOCATION OF PIPE LINES. B. TRENCH DEPTH. C. REQUIRE:D SE:PARA TION (HORIZONTALLY AND VERTICALLY). D. PIPE IDENTIFICATION. E. POINTS-OF-CONNECTION (Poe's). F. LOCATION AND IDENTIF1CA TION OF SPRINKLER HEADS. G. WARNING SIGNS AT THE SITE AND ON THE TRUCKS HAULING RECYCLED WATER (IF RECYCLED WATER IS USED FOR CONSTRUCTION), AN APPROVAL LETTER REGARDING THE INSPECTION OF THE PROJECT SHALL BE OBTAINED FROM THE CITY AND THE DISTRICT, AND BE FORWARDED TO THE SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH PRIOR TO FINAL INSPECTION APPROVAL. DISTRICT FINAL /NSP£CTION SHALL INCLUDE: A. COVERAGE TEST, AFTER COMPLETION OF THE SPRINKLER SYSTEM, TO D£TERMIN£ 1HE ADEQUACY OF COVERAGE ON THE APPROVED USE ARE:A AND PROTECTION OF AREAS NOT APPROVED FOR RECEIVING RECYCLED WATER. B. WARNING SIGNS AND LABELS. C. QUICK COUPLING VALVES. D. ALL ASPE:CTS OF THE IRRIGATION CONDITIONS INCLUDING WINDBLOWN SPRAY, RUNOFF, AND PONDING. £. lfEQUlffED PROTECTION OF ALL RESIDENTIAL ARE:AS. F. REQUIRED PROTECTION OF WE'LL, STREAMS, RESERVOIRS, ETC. G. CROSS-CONNECTION. .032 ALUMINUM, .060 ABS PLASTIC OR STia<-ON VINYL SIGNS .032 ALUMINUM, .080 ABS PLASTIC J. OR STICK-ON VINYL SIGNS ANNUAL INSPE:CTION SHALL INCLUDE:: A COMPl.£TE INSPECTION WHICH SHOULD COVU/ PART A, PART B AND PART G OF TH£ DISTRICT FINAL INSPE:CTION. TYPICAL SIGNS REVISIONS MUST 8£ APPROVED BY PUBLIC HEAL TH ENGINEER, CITY ENGINEER &: DISTRICT ENGINEER PRIOR TO IMPLEMENTATION IN FIELD. RECYCLED WATER SYSTEM (PRIVATE) 6305 EL CAMINO REAL 92009 CARLSBAD, ,-· -----:--. '' •'··-- EX. FIRE HYDRANT RC RC CA I I I I I EX. 6" FIRE / t',r_ RC ( j . --~----~.-.-.-~. -_-:_.-.. -------_ .. ;;-_ . .,.. __ -."'d'!F\l"'J"': l""--~·--=;'"• --:-:: ... :.:,,-,-·.,"':~::,.,_--_ .. __ .... __ -_""·:::.;:::.-... ~-... ·""· ;::::;:,:::,:::.:.··""-..._-·="" I LEGEND --Ex. 6" FIRE--'"' EXISTING POTABLE WA1ER FIRE SYSTEM AND METER ----Fx. 2" Dw = EXISTING POTABLE WA 1ER DOMESTIC SYS7EM AND METER ---Re PROPOSED RECYCLED /RR/GA TION SYS1EM f. .RJi'·fJ5+~!£:<h@AY5fHf-i-"<1 AREA OF RECYCLED WATER USE L--,rn,., ___ RC LOCATION OF CONNECTION POINT/S-METER &: I BACKFLOW PREVENTION D "DO NOT DRINK" SIGN LOCATIONS SHEET INDEX SHEET TITLE SHEET NUMBER SHEET REF. CITY OF CARLSBAD RECYCLED D.E.H. TITLE SHEET IRRIGATION PLAN IRRIGATION PLAN IRRIGATION LEGEND & NOTES IRRIGATION DETAILS /RR/GA TION DETAILS /RR/GA TION DETAILS /RR/GA TION DETAILS ENGINEER'S SIGNATURE APPROVED WATER SHEET l-"'~::.,,..~-~_,'Q"P"""'-___ 5=-,;I.·,?# ENGINEERING PLAN CHECKER DA TE 1 T-1 2 T-2 J Ll-1 4 LJ-2 5 U-J 6 U-4 7 LJ-5 8 LJ-6 9 Ll-7 NO. i i KEY MAP rr-;:;;;:;;;:;;:;;;:;;:;;;:;;:;;;:;:;;;:;;:J;;;;:;;;:;;;;:;;;;~~i::,------i__., I I I I I I I I I Ll-2 Ll-1 , / I I I I I L ____ .,1_ __ _;_ ...J "AS BUil T" TITLE DATE REVIEWED BY: INSPECTOR DATE 1-w w I (f) a:: w i Cl w ...J (.) >-(.) w a:: Cl <( CD (f) ...J a:: 5 LL 0 ~ -(.) T-1 CARIBBAD MUNICIPAL WATER DISTRICT SHEET 1 CITY OF CARLSBAD PLANNING DEPARTMENT 9 SHEETS CARLSBAD MUNICIPAL WATER DISTRICT WILLIAM E. :LUMMER R.C.E. 26176 ,41¾Q({ NO. 6305 El CAMINO REAL DESCRIPTION APPROVED DATE DEVELOPERS NAME:____________ CARLSBAD, CALIFORNIA 92009 1---1---------------1-------+---lADDRESS: DEPUTY CITY ENGINEER EXP.6/30/08 TELEPHONE: _____ _ DATE PLAN PREPARED: _________ _ APPROVED BY: DATE 1---1---------------1-------+---1 BY: PLANNING DRv.t.l BY: CHct<D BY: DN MP PROJECT NO. PD07-09 lz·9:.e'b DATE DRAWING NO. 455-4L .r: (J1 Ul ' ..r. r - ~ .,J) , RECYCLED WATER STANDARD PLAN NOTES l ALL I.IJORK SHALL BE fN ACCO~ANCE WITH THE CARL.SBAO MUNICIPAL WATER DI5TRICT RULE& AND RECsULATIONa. 2. DRlNKINCs WATER FOUNTAINS AND DESIGNATED OUTDOOR EATfNG AREAS &HALL 6E PROTECTED AGAINST CONTACT WITH RECYCLED WATER &PRAY, Ml&T, OR RUN-OFF. 3. BEST MANAGEMENT PRACTICE& 51-!ALL BE USED TO ELIMINATE C>R CONTROL TO THE BEST E><T!;NT FOSSll;ILI; PONDINc::r, ~-OFF, OvERSPRAY, AND MISTINa... , ' 4. HOSE 6165 ARE 5TRICTL Y PROHIBITED. S. CR055-CONNECTION5 SETWEEN RECYCLED WATER LINES AND POTABLE WATER LINES ARE STRICTLY PROHIBITED. ' ' ' e,. NO 5U6STITUTIQNS OF FIFE MATERIAL& WILL 6E Al.LOWED . WITHOUT PRIOR APPROVAL OF THE LEUCADIA WATER DISTRICT. 1. ALL MAINLINE PIPES SHALL HAYE;: WARNING T AF!; FER THS CARL.56AD MUNICIPAL WATER DISTRICT RULES AND REGULATIONa. a. HOUR& FOR !RRIGLAT[ON WITH RECYCLED WATER ARE F~ S:00 P.M. TO E:,,IZ)IZ) A.M. THE HOURS FOR IRRIC:ATION WITH DISINFECTED TERTIARY RECYCL!:D WATER MAY eE MQDIFll:D BY LOCAL AUTHORITY. IAAluATION DURING Pl.IBLIC US!; .. PERI005 WITH OISINFECTED TERTIARY RECYCLEO WATER . 51-!ALL 6E UNDER SUPERVISION OF THE DESIGNATED USER 5UPERVl50R. IRRIGLATION WITH WATER OF A LESSER QUALITY THAN DISINFECTED TERTIARY RECYCLED WATER SHALL BB 6ETWEEN THE 1-!0URS Or S,00 PM. AND b,IZ)fb AM. 'a 61.JRIAL OF ALL WIRING AND PIPING SI-IALl. MEET Tl-IE LEUCADIA WATER Dl5TRICT RULES AND REGUL,._ATION&. '"· NON-DESIGNA Tl:P us~ AREA& &HAI.I. eE PRQTl;CTED FROM CONTACT Wlil-l ~CYCLl:O WAfER, LIJl.jefl-l!;R e,-U)INP6l.OY.N SPRAY Ori! BY DIRECT APPLICATION THROUGH IF<RIC1iAflON OR OTI-IER USE. LACK OF PROTECTION, WHl:fl-lER BY DESIGN, CONSTFa.JCTION PRACTICE, OR SYSTEM OPERATION 15 SfRICTL Y FROI-IIBITED. IL IRRIGATION 1-!EADS SHALL 6E RELOCATED OR ADJUSTED TO MINIMIZc OR eLIMINATE: OVER-QFRAYINCs ONTO &IDEWAUG, 5TREET5, AND NON-Dl:SIG!NATED U&E AREA&. 12. RE!CYCLED WATER QUICK COUf'L_INC. VAl.vee &HALL 61: OF A TYPE DE5IGINEO !=OR use ON RECYCLED U)ATl;R Dl$TRJeYTl<;?N SYSTEMS PER fl-IE LEUCADIA WATER DISTRICT RIJl-~S AND REGULATIONa. 13. ON RECYCLED WATER 5Y5TEM5, ALL APPURTENANCES CPIPfNG, SPRINKLER I-IEADS, VALVE BOXES, ETCJ SI-IALL 68 COL.OR-CODED (FURPLEJ IN ACCORDANCE WITH AMERICAN WATER l.!.JOF1J<5 ASSOCIATION (AU..WA) GUIDELINES AND SECTION 116815 OP Tl-IE CALIFORNIA HEAl. Tl-I AND SAFETY CODe. 14. ALL IAAIC.ATION PIPES SHALL 65 STl;NCILi;D I.VITI-I Tl-lE! WAFiN!NC:., irNON-P6TA6LE OR RECYCLED WATER." COLOR-CODED (PURPLE) ANO LAID WITI-I WARNINC:1 t APE AND STENCILfNC:s TOWARD THE TOP OF Tl-IE TRENCI-I FER TI-IB CARL&6AO MUNICIPAL WATER DISTRICT'S RULES ANO REC:iULATION8. ., . . . IS. ON NEW ON-SITE &Y&TEMS <POST-METER>, POTABLE WATER. CONSTANT PRESSURE RECYCLED WATEFi! ANO SEWER LINE€> 51-!0ULD 6E A PLACED A MINIMUM OF FOUR (4) FEET APART Ofa AS DIRECTED 6Y Tl-IE PROJECT ENGINEER AND/ OR REGU1.ATORY AGENCY. MEASUREMENTS SHALL 6E BETWEEN FACING SURFAC!=S, NOT FIFE CENTERLINE&. 16. CONSTANT PRESSURE RECYCLED UJATER LINE& SHALL CROSS AT LEAST TWELVE (12) INCHES 6E=LOW FOTA6LE WATER LINES AND MAINTAIN Ar LEAST TWELVE INCHES CROSSING SEPARATION 6EiuJEEN OTl-fER UTILITIE5. -- 11. IF= A CONSTANT PRESSURE RECYCLED WATE~ LINE MUST ee INSTALLED ABOVE A POTABLE WATER LINE OR LESS THAN TWEL YE (12) INCHES BELOW A POT ABLE WATER LINE, TI-IEN THE RECYCLED WATER LINE SHALL 6E INSTALLED WITI-IIN AN AFFkOVED PROTECTIVE SLEEVE AS FER Tl-IE CARLSBAD MUNICIPAL WATEk.DISTRICT'& RULE& AND REGULATIONS. 18. DEVeLOP!:R/ CONTRACTOR 51-!ALL CONDUCT A c~SS-CONNECTION TEST AND COVERAGE TEST A5 DIRECTED SY ii-IE CARLSBAD MUNICIPAL WATER DISTRICT AND CQUNTY OF SAN DIEGO, DEPA~THENT OF ENVIRoNHENfAL Hl:ALT14, PRIOR TO ANY USE OF RECYCLEO WA TEl't. l'a THE REQUIRED CROSS-CONNECTION fN5FECTION 51-TALL 65 DONE 6Y EITHER Tl-IE LEUCADIA WATER DISTRICT AND/ 0~ THE COUNTY OF SAN DIEGO, DEPARTMENT OF ENvlRONMENTAL Hl;Al. Tl4, COPIES OF INSPECTION REPORTS WILL ee FORIJJARD!;D TO THE NON-INSPECTING FARTY. 20. THE DESIGN AND LOCAfl6N5 PROPOSED FOR RECYCLED WATER "DO NOT DRINK" SfGNS SHALL ee CALLEO OUT ON THI:! Pl.AN~.• . ' . . 21. WHEN kECYCLED WATEk 6ECOME5 AVAILA6LE. AN ON-SITE USER SUPERVI50R SHALL 61= DE5IG!NATED IN WRITING. THl5 INDIVIDUAL SI-IALL BE FAMILIAR WITl-l PI.UM61NG $Y$Tl;M& WITI-UN THE PROFERTY, Wlil-l ii-IE BASIC CONCEPTS ~ SACKFLOUJ/CROS5-CONNECTION FROTECTIC'iN, RECYCLED PURVEYOR'S Fa.JLE5 AND REGULATIONS AND Tl-IE 5FECl!=IC:: REQUIREMENTS OF A RECYCLED WATER IRRIGATION 5Y5TEM. COPIES OF THE DESIGNATION, WITH CONT ACT PHONE NUMBERS, SHALL BE PROVIDED TO Tl-IE CARLSBAD MUNICIPAL WATER DISTRICT AND COUNTY OF SAN DIEGO, DEPARTMENT OP ENVIRONMENT AL I-IEAL TH. IN CASE OF EME;~!;NCY CONT ACT, CARL HAH!;R •= <1i&rt>> 45>s-2ic:::>) OR AFTER I-IOUR9, CONTACT, CABI-I-IAMER •= <1i&c:::>J 4SS-21~~ 22. ALL RJBLfC AND PRIVATE POTABLE WATER MAfN5, INCLUDING Fike SERVICE MAIN& AND ANY WATER WELLS AND WATER COURSES WITHIN Tl-IE RECYCLED WATER PROJECT LIMITS el-lAW.. eE SHOIJ.N ON THE IMPROVEMENT PLANS, SEE SI-IEETS LI-I ANP 1,..1-::Z. 23. CALL OUT ON Tl-IE PLANS IF THERf: Ake OR A~ NOT DRINKING FOUNTAINS ANO/ OR DESl6NATED OUfDOOR EATING AREAS ON Tl-1I5 51TB. 24. EDUCATE ALL MAINTENAl'-ICE PERSONNEL ON A CONTfNUOl.19 6ASl5 OF THE PRESENCE OF RECYCLED WATER. PERSONNEL. MUST BE INFORMED THAT RECYCLED WATER 15 MEANT FOR IRRIGATION PURPOSES ONLY, AND 15 NOT APPROVED FOR DRINKING PURPOSES, HAND WASH, CLEANING OF TOOLS ETC. GlvEN THE HIC:i:1-1 TURNOVEk RA TE OF EMPI.OYEES IN THe LANDSCAPE INDUSTRY Ir 15 IMFQRTANT THl5 INFORMATION ee DISSEMINATED ON AN ALMOST DAIL y eAsl&. .;f ' 2S. A PHYSICAL SEPARATION 51-lALL BE F~VIDEO BETWEEN ADJACENT AREAe IRRIGATED WITl-1 R!;CYCLl;D WATl;:R ANP WITH FOT ABLE WA fER. SEPARA ilON SHALL ee PROYID!;D i,y DISTANCE, CONCRETE MOW 5TRIF5 OR Ofl-lER AFFRO'VEO METI-IOD5 26. FINAL IRRIGATION AS-BUii-T PLANS WILL 6E REQUIRED TO SE REVIEWED AND APPROVED 6"f THE CITY, AND FINAL MYLARS WILl. BE REQUIRED TO 6E APPROVED AND SIGNED 6Y Tl-le CITY OF CARL.56AD PRIOR TO PLANNING DEPARTMENT SIG:NING THE Fl::RMIT CARD. INSPECTION PROCEDURES IN5FECTION OF THI: PROJECT e,1-1ALL 6E PERFORMED 6Y THE LAND&CAPE ARCI-IITECT OF THE I-IORJ<, OR HIS DESIGNATED AGENT. REFER TO THE SPECIi=ICATION5 OF THE SCHEDULE; OF REQUIR.E:D IN6FECTION6 ANt? REQUIRED SueMITTALS. FOLLOl-lfN6 ~PLETION OF fl-le HORI<, TH!: LANDSCAPE ARCHIT!:CT OF THE HORI< HILL CERTIFY THAT THE INSTA!..LATION HAS BEEN COMPLETED SY SUSMITT!Na. Tl-IE 'FINAL LANOSCAFE CERTli=ICAtOIN FORM." A R(::QUl;ST FOR A FINAL LANDSCAPE INSPECTION 6Y THE CJTY MUST ALSO eE MADE BY CALLING Tl-IE IN5PECTON REQUEST LrNS. . ' ' "FINAL LANDSCAPE CERTIFICAT[ON FORM' FAX TO 1i&IZ'-S44-8S43 LAND6CAPE INSPECTION REQUEST PI-IONE LINE, 1blZ)-blZ)2-4blZ)l -. . -' . . . RECYCLED WATER SYSTEM · VIASAT · - RECYCLED/ WATER USE MAP I ' ---1 ' -~:: =:i:::"·., ~tml!..l.ll.JJ.l ll.!11...L! !!...!..l.lli..l!l.LLI I .L!.I IJJ!J..LL.!..H:;~~ --f· -- I 11 111111111· I l'rinr1i1TflTTFr1 rrTt;Tir". I ~ ... · .. LllliJ I !JI LI l,ll lJJJillJ~.JJ I I~ l l .!_11~1.1.11!),•.: •• I E OOR,M NOTTOSCAUI rn NORTH NOTTOSCAUI I • UC ~_,' I LEGEND / RECYCLED WATER POINi/ · JC CONNJCTION ON NON-PdTABLE, NON-PRESSURE~IPE RECYCLED WATER "DO NOT DRINK" SIGN Rl;CYCLEQ WATER USE AREA RECYCLED WATER MAINLINE --<'EX. 6" FIRE--'llll POTABLE WATER MAIN LINE AND METER --<EX. 2" ow --£1111l FIRE SERVICE ANO METER LOCATION MAP WILLIAM E. PLUMMER R.C.E. 28176 DATE DEPUTY CITY ENGINEER EXP.6/30/08 SAN DIEGO COUNTY HEALTH DEPARTMENT APPROVED BY: ~--_ ·-· _ DATE VICINITY MAP ENGINEER"S SIGNA lUR! APPROVED • OGvenbein • Raricho Santo f• ..... ~=~=' 1-_ .. _.L;1!3C.-___ ,r~,4 ENGINEERING PLAN CHECKER DA TE ~f------------+----+-----1 ---o -=-----·" DECLARATION OF LANDSCAPE ARCHITECT WORK I HEREBY DECLARE THAT l AM THE LANDSCAPE ARCHITECT OF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGES OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE AND THE THE DESIGN is CONSISTENT WITH CURRENT SiANOAROS. . I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPEC !FICA TIONS BY THE CITY OF SAN DIEGO AND THE SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH IS CONFINED TO REVIEW ONLY AND DOES NOT RELIEVE ME, AS THE LANDSCAPE ARCHITECT OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. - E. REGISTRATION N0:_1-'D~;,...l~f2!!!;;....~----- EXPIRATION DATE: -e.&~-,._·~JL-a-[•-=O'J_._ ___ _ SHEET INDEX SHEEl SHEET TITLE SHT. REF. NO. -NO. T-1 CITY OF CARLSBAD RW TITLE SHEET 1 T-2 D.E.H. RW TITLE SHEET 2 Ll-1 IRRIGATION PLAN 3 Ll-2 IRRIGATION PLAN 4 Ll-3 IRRIGATION LEGEND & NOTES 5 Ll-4 IRRIGATION DETAILS a Ll-5 IRRIGATION DETAILS 7 Ll-6 IRRIGATION DETAILS 8 Ll-7 IRRIGATION DETAILS 9 RECYCLED WATER nDO NOT DRINK" SIGN 1 WE ARE CONSERVING OUR MOST VALUABLE RESOURCE BY IRRIGATING OUR LANDSCAPE WITH RECYCLED WATER RECYCLED WATER AGUA RECICLADA DO NOT DRINK NO TOME EL AGUA COUNTY OF SAN DIEGO DEPARTMENT Of ENVIRONEMENTALKEALTH APPROVED niu: REVIEWED BY: INSPECTOR TELEPHONE: 12" "AS BUil T" ,,. DATE DATE ::c ~ :c ~· f--z t-w W ~w ZI 0 (/) Ct!~ -..... >-z t-w et:: LL W Qt-. <( !zs wo ~w J-_J a::: (.) <( >- 0.. (.) WW 0~ T-2 DATE PLAN PREPARED: _______ _ DN PROJECT NO, DRAWING NO. 1:,:,:,==a=~-HP---fPDQ7-Q9 455-4L BY: ...c 81 • J: , t' ~ J/J ------------~---------- IRRIGATION POINT OF CONNECTION: I. CONSTRUCTION KE'Y NOTES: 0 POINT OF CONNECTION TO EXISTING IRRIGATION MAINLINE WITH NEW SCHEDULE 4i?> PVC MAINLINE (SIZE PER PLAN) AFFROXIMATEL Y Wl-lERE SHOWN. CUT AND CAP EXISTING IRRIGATION MAINLINE I POINT OF CONNECTION AT NEW RECLAIMED WATER METER, REFER _, _, \ \11\ TO NOTE 411, THIS SHEET _,,,,-_,,,,,, w4' \t11 RECYCLED WATER I POINT OF CONNECTION AT NEW 1" RECYCLED WATER METER (APPROXIMATELY Wl-lERE 51-!0WN) AND EXTEND PER PLAN. Tl-lE OWNER (FIRST INDUSTRIAL REAL TY • TRUST) 51-lALL COORDINATE AND PAY ALL ASSOCIATED FEES FOR THE INSTALLATION OF Tl-lE RECYCLED WATER METER 6Y Tl-lE CARL56AD MUNICIPAL WATER DISTRICT. RECYCLED WATER SHALL 6E SUPPLIED 6Y Tl-lE C.M.W.D .. FIELD VERIFY LOCATION OF EXISTING IRRIGATION MAINLINE PRIOR TO CONSTRUCTION. CONNECT TO EXISTING IRRIGATION MAINLINE (FIELD VERIFY EXACT LOCATION) WITl-l NEW MAINLINE. CONTRACTOR SHALL CUT AND CAP EXISTING IRRIGATION MAINLINE AT ALL POINTS OF CONNECTION TO EXISTING DOMESTIC WATER MAINLINES. FIELD VERIFY PRESSURE AT POINT OF CONNECTION, EXISTING MAINLINE SIZES AND LOCATIONS OF ALL EXISTING EQUIPMENT PRIOR TO 6EGINNING WORK. UPSTREAM OF POINT OF CONNECTION. CONTRACTOR SHALL VERIFY Tl-lAT NO OTl-lER CONNECTIONS EXIST 6ETWEEN EXISTING DOMESTIC WATER MAINLINE AND ANY IRRIGATION MAINLINE. SEE ADDITIONAL "EXISTING POTA6LE WATER" NOTES, Tl-llS SHEET. I _,,,,-\\\\\ "DO NOT DRINK" SIGN \\\\\ (TYPICAL 5YM60L)~ L __ EX. 6" FIRE ------------------'-----------~ ,-----------------='-'--'-'--=----'--'-'--"'=----------~ EXISTING POT ABLE ~ATER NOTES: I. EXISTING DOMESTIC WATER AND FIRE SERVICE SIZES AND LOCATIONS ARE 6ASED ON CONSTRUCTION DOCUMENT MP-I (C.M.W.D. NO. 11-2i?>1) 6Y PETER A. LENDRUM AND ASSOCIATES, DATED 8-4-11. LOCATIONS ARE SHOWN DIAGRAMMATICALLY FROM DRAWING MP-1 AND SHOULD NOT 6E CONSIDERED "A5-6UIL T". Iv," 'ii \ FH § \ e I I 2" \ /ll'.....----:::;; ~,s--~ ¥. :: ~ x. 2" Q J,(1 -/...--_ --+:S/MV I 1-' RECLAIMED WATER METER (6Y C.M.W.D.) EXISTING COPPER SERVICE LINE 0 POINT OF CONNECTION TO EXISTING IRRIGATION MAINLINE WITl-l NEW lv2" SCHEDULE 4i?> PVC MAINLINE (FIELD VERIFY EXACT LOCATION). I I I I I 2. CONTRACTOR SHALL EXPOSE ENTIRE LENGTH OF EXISTING DOMESTIC WATER MAINLINE, IDENTIFY ALL POINT OF CONNECTIONS TO THE EXISTING DOMESTIC WATER MAINLINE WITH IRRIGATION MAINLINE, CUT AND CAP THE IRRIGATION MAINLINES AND VERIFY THAT NO OTHER CROSS CONNECTIONS EXIST ALONG THE ENTIRE LENGTH OF THE EXISTING DOMESTIC WATER MAINLINE. ........ ----+~-ex. 8" Fl --©-i 6ACKFLOW PREVENTER WITl-l WYE STRAINER AND PRESSURE REDUCING VALVE ©CONTRACTOR 51-lALL VERIFY EXISTING SPARE WIRES AT THE END OF MAINLINE RUNS. IF NO SPARE WIRES EXIST, CONTRACTOR 51-lALL INSTALL AND ADD NEW VALVE 'A4" TO EXISTING VALVE MANIFOLD AND TO THE IRRIGATION CONTROLLER VIA Tl-lE "QUICK LINK" 6Y REED'S IRRIGATION SERVICES, INSTALL PER MANUFACTURER'S INSTRUCTIONS AND DETAIL 1-l/ Ll-4. VERIFY Tl-lAT Tl-lE EXISTING VALVE HAS TWO GOOD POWER WIRES, A 1-lOT WIRE AND A COMMON WIRE. INSTALL NEW VALVE A4 ON MANIFOLD WITH EXISTING VALVE APFROXIMATEL Y WHERE 51-lOWN ON PLAN. CONTRACTOR 51-lALL 6E PREPARED TO TRENCH 6ACK TO THE IRRIGATION CONTROLLER WITl-l CONTROL WIRE IN Tl-lE EVENT Tl-lAT Tl-lE VALVE CANNOT 6E ADDED TO Tl-lE VALVE SEQUENCE USING THE 'QUICK LINK". 0 Al 24 1-1/2" EXISTING IRRIGATION SYSTEM 15 POT A6LE. UPON CONVERSION TO RECLAIMED WATER, ALL EXISTING IRRIGATION EQUIPMENT SHALL 6E MARK.ED NON-POTA6LE AS NOTED: • EACH EXISTING SPRAY HEAD ON RISER SHALL HAVE A RECLAIMED WATER WARNING STICKER PLACED ON THE RISER (CHRISTY'S 415Ii?>i?> RISER MARK.ER) EXISTING 2" PVC SCH 4i?> MAIN (FIELD VERIFY) I I I I Ill I (}'.'. :r u.. a • ~ -.Q N . X X Ill Ill I 3: J • EACH EXISTING POP-UP SPRAY HEAD SHALL HAVE AN AFTER MARKET NON-POT A6LE COVER INSTALLED (SEE ORIGINAL MANUFACTURER FOR MODEL NUM6ER). IF NONE AVAILA6LE, THE TOP OF EACH SPRAY HEAD 60DY SHALL 6E PAINTED PLIRPLE • EACH EXISTING VALVE SHALL 6E TAGGED WITH A RECLAIMED WATER WARNING TAG (CHRISTY'S •iD-MAX-P2-RC006) D SEE SHEET T-2 FOR ADDITIONAL RECLAIMED WATER SIGNAGE NOTES " I TO PROTECT OUTDOOR EATING AREAS FROM CONT ACT WITH RECYCLED WATER, USE FLOOD 6U66LER5 IN RAISED PLANTERS. IN EXISTING PLANTING AREAS ADJACENT TO OUTDOOR EATING AREAS, REPLACE EXISTING NOZZLES WITH VARIA6LE ARC, LOW TRAJECTORY, NOZZLES (RAIN6IRD 12' VAN NOZZLES) EXISTING VALVE TO 6E REMOVED (TYPICAL 5YM60L) 6 EXIS ING lv." P I EXISTING IRRIGATION MAINLINE LOCATION SHOWN ON OUPtER, 1'YPICJ4L 5 THESE PLANS ARE 6ASED ON THE ORIGINAL IRRIGATION I PLAN 6Y PETER A. LENDRUM ASSOCIATES, DATED JULY 1, 1'311. PRIOR TO CONSTRUCTION, CONTRACTOR SHALL FIELD VERIFY ALL EXISTING MAINLINE LOCATIONS, SIZES AND I SPARE CONTROL WIRES. I I ---- r 60 EXISTING PLANTING AND IRRIGATION TO REMAIN (TYPICAL 5YM60L). MODIFY/ REPAIR IRRIGATION SPRAY 1-lEAD LAYOUT AS REQUIRED TO PROVIDE COMPLETE WATER COVERAGE TO THE ENTIRE PLANTER AREA. SEE IRRIGATION SPRAY/ ROTOR 0 1-lE D LEGEND FOR REPLACEMENT NOZZLES. NORTH 0 I ~ f/ 0 EXISTING REMOTE ~ CONTROL VAL VE TO REMAIN / (TYPICAL 5YM60L) fa I I I I I I I I EXISTING lv2" PVC SCH 4i?> MAIN TO REMAIN (FIELD VERIFY J I I I I I MASTER VALVE (NOFi:MALLY CLOSED) FLOW SENSOR STATIC WATER PRESSURE 1S2 PSI <HGL=SSi?>, 06TAINED FROM Tl-lE CARL56AD MUNICIPAL WATER DISTRICT, 16i?>-438-2122) DESIGN WATER PRESSURE 61 PSI MAXIMUM FLOW <FIELD VERIFY) SI GPM PRESSURE REGULATOR SETTING 8IZ> PSI <SEE SHEET Ll-2 FOR PRESSURE LOSS CALCULATION) VERIFY SIZE, LOCATION AND PRESSURE IN FIELD WITl-l OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO 6EGINNING CONSTRUCTION. IRRIGATION CONTROLLER: 2. CONTROLLER SHALL 6E WALL-MOUNT UNIT WITH STAINLESS STEEL ENCLOSURE. 2i?>A, IISVAC POWER REQUIREMENT PROVIDED 6Y ELECTRICAL CONTRACTOR. FINAL LOCATION OF CONTROLLER, ELECTRICAL POC, AND APPLIRTENANCES 51-lALL 6E CONFIFi:MED WITl-l OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO COMMENCING WORK. REFER TO CIVIL DRAWINGS FOR EXACT LOCATION OF ELECTRICAL POINT OF CONNECTION. 16 AVAILA6LE STATIONS li?> EXISTING STATIONS (FIELD VERIFY) 4 NEW STATIONS IRRIGATION NOTES: 0 EXISTING IRRIGATION CONTROLLER <LOCATION TO 6E FIELD VERIFIED) TO 6E SALVAGED AND RETURNED TO OWNER. PROTECT IN PLACE EXISTING CONTROL WIRES, MAKE ENDS WATERPROOF, TAPE AND LA6EL AND PLACE INSIDE VALVE eox FOR FUTURE CONNECTION TO NEW CONTROLLER. ©CONTRACTOR SHALL TRENCl-l AND INSTALL NEW MASTER VALVE WIRE AND FLOW SENSOR CA6LE (IN lv2" CONDUIT) FROM NEW CONTROLLER LOCATION TO NEW MASTER VALVE AND FLOW SENSOR LOCATION. ©EXISTING VALVE LOCATED IN NEW CONSTRUCTION AREA, AFPROXIMATEL Y WHERE SHOWN, TO 6E REMOVED AND REPLACED WITl-l NEW VALVE. REFER TO KEYNOTE-, FOR INSTRUCTIONS ON SYSTEM REPAIR. 0 CONNECT NEW VALVE, MENTIONED IN PREVIOUS KEYNOTE IIE,, TO EXISTING SYSTEM AND MODIFY/ REPAIR AS REQUIRED TO PROVIDE CONTINUED AND COMPLETE IRRIGATION SERVICE TO Tl-lE EXISTING PLANTER. 0 CONTRACTOR SHALL PROTECT IN PLACE ALL EXISTING PLANTING AND IRRIGATION TO REMAIN. ANY PLANT MATERIAL OR IRRIGATION DAMAGED DURING CONSTRUCTION 51-lALL 6E REPLACED 6Y Tl-lE CONTRACTOR AT NO ADDITIONAL COST TO Tl-lE OWNER. 0 5AWCUT AND REMOVE ASPHALT PAVING AS REQUIRED TO INSTALL IRRIGATION MAINLINE, (2) 4" SPARE SLEEVES AND WIRE CONDUIT. ;;::\EXISTING REMOTE CONTROL VALVES TO REMAIN SHALL PROVIDE \'.:::/CONTINUED IRRIGATION SERVICE. VERIFY THAT EXISTING VALVES ARE DOWNSTREAM OF MAINLINE CAP PRIOR TO CUTTING AND CAPPING Tl-lE MAINLINE. MODIFY/ REPAIR AS REQUIRED FOR CONTINUED SERVICE. 3. EXISTING IRRIGATION INFOFi:MATION 15 6ASED ON CONSTRUCTION DOCUMENTS 6Y PETER A. LENDRUM ASSOCIATES, DATED JULY 1, 1'311 AND FIELD WORK CONDUCTED 6Y MWPA. CONTRACTOR SHALL FIELD VERIFY EXISTING IRRIGATION SYSTEM FOR ACCURACY. 12. FULL (2) SPARE CONTROL WIRES AND Tl-lE COMMON WIRE FROM CONTROLLER TO ALL NEW MAINLINE END RUNS. LOOP IN ALL NEW REMOTE CONTROL VALVE 60XE5 ALONG NEW MAINLINE RUN. MAKE WIRE ENDS WATERPROOF, TAPE AND LA6EL AS "SPARE WIRES", AND PLACE li?>' COIL INSIDE VALVE eox, TYPICAL. 4. SEE SHEETS Ll-3 THROUGl-l Ll-1 FOR IRRIGATION EQUIPMENT SCl-lEDULE, NOTES, DETAILS AND ADDITIONAL INFOFi:MATION. S. VERIFY VALVE LOCATIONS IN Tl-lE FIELD WITH OWNER'S AUTl-lORIZED REPRESENTATIVE PRIOR TO COMMENCING WORK. 6. LATERAL LINES ARE SHOWN WITl-llN PAVING FOR CLARITY ONLY, ACTUAL LOCATION TO 6E WITHIN PLANTER. CONTRACTOR 51-lALL CONFIFi:M ALL LAYOUT IN FIELD WITH OWNER'S AUTl-lORIZED REPRESENTATIVE PRIOR TO COMMENCING WORK. 1. MAINLINE SHOWN WITl-llN PAVING FOR GRAPl-llC CLARITY ONLY, ACTUAL MAINLINE LOCATION TO 6E A MINIMUM OF 18' OFF ADJACENT HARDSCAPE AND OTl-lER 065T ACLES, TYP. 13. CONTRACTOR SHALL PROTECT IN PLACE ALL EXISTING PLANTING AND IRRIGATION TO REMAIN. ANY PLANT MATERIAL OR IRRIGATION DAMAGED DURING CONSTRUCTION 51-lALL 6E REPLACED 6Y THE CONTRACTOR AT NO ADDITIONAL COST TO Tl-lE OWNER. 14. CONTRACTOR SHALL VERIFY FLOWS FOR ALL EXISTING REMOTE CONTROL VALVES. UPON REPLACING SPRAY HEAD 60DIE5 AND NOZZLES, CONTRACTOR Sl-lALL VERIFY Tl-lAT NO ZONE EXCEEDS A MAXIMUM FLOW OF 32 GALLONS PER MINUTE. VALVES HAVING FLOWS LARuER Tl-lAN 32 G.P.M. ARE EXCEEDING Tl-lE MAXIMUM SAFE FLOW (S FEET PER SECOND) THROUGl-l SCl-lEDULE 4i?> PVC MAINLINE. z CONT ACT LANDSCAPE ARCl-llTECT FOR DIRECTION ON 1-lOW TO <( PROCEED. KEY MAP .....J fa 8. IRRIGATION SYSTEMS ARE TO 6E INSTALLED AS SHOWN IN Tl-lE DETAILS AND SPECIFICATIONS. CONTRACTOR SHALL 6E RESPON5I6LE TO COMPLY WITl-l LOCAL CITY, COUNTY, AND ST ATE REQUIREMENTS FOR 60TH EQUIPMENT AND INSTALLATION. a.. z 0 I I 10 20 40 60 li?>. CONTRACTOR 51-lALL ADJUST ALL 1-lEADS AS REQUIRED TO ACCOMMODATE ANY VERTICAL 06STRUCTION5 THAT MAY OCCUR, INCLUDING 6UT NOT LIMITED TO LIGl-lT POLES, FIRE HYDRANTS, ETC. VERIFY ALL 1-lEAD LAYOUT WITH OWNER'S AUTl-lORIZED REPRESENTATIVE PRIOR TO COMMENCING WORK. 11. REFER TO IRRIGATION SPRAY HEAD AND ROTOR LEGEND FOR SELECTION OF REPLACEMENT SPRAY, ROTORS AND NOZZLES. REMOTE CONTROL VALVE CALLOUT: STATION SEQUENCE VALVE SIZE APPROX.GPM PROJECT SITE ~ (..9 -0::: 0::: - Ll-1 "AS BUILT" TITLE DATE REVIEWED BY: INSPECTOR DATE CARLSBAD MUNICIPAL WATER DISTRICT SHEET CITY OF CARLSBAD g 3 PLANNING DEPARTMENT SHEETS CARLSBAD MUNICIPAL WATER DISTRICT l--'-'Nc::cO·+-----"-'DE==S..::::CR.:::IP....:.Tc::.IONc:.._ ___ +:-A.::...P:...:.PR.:..:::O..:..:VE:::cD+:::-:DA..:..:T=-1E DEVELOPERS NAME:----------CAR~~~L:r~:~2009 f--+-----------+---+---!ADDRESS: WILLIAM E. PLUMMER R.C.E. 28176 DEPUTY CITY ENGINEER EXP.6/30/08 DATE SAN DIEGO COUNTY HEALTH DEPARTMENT AP~ J\-~ Cf· ~\__;L 5-~·Cfb TELEPHONE: _____ f-P_LA_N_NIN_G ____ ~---~---DA_TE_--1 f--+------------+----+----1,__ ______________ __.,DRWN BY: DN PROJECT NO. DRAWING NO. DATE PLAN PREPARED:________ ,__ _____ ___, SCALE: 1"=20' APPROVED BY: _D_A_TE_ 1---+-----------+---+-----l BY: CHC!<D BY: MP PDQ 7-09 455-4L I I mi~---------------~ --t E . FIIRE HY R..LNT [[g .,,, " "''·' 111 II : I::: I 1,111 I 111 I 'v I I fl (i'-,!-------------------------T1rmr----EX. 6" FIRE ...-r-FROVIDE (2) 4" &FARE SLEEVE& r::\__~1,1 11 Ct] ~ I II ~! 1 ~ l ' 1 l l ' la .b 0 ~ ~I I 1,111 I 111 1,111 #i,tj~IIII ml A3 ~ I" EXISTING IRRIGATION SYSTEM 15 POTABLE. UPON CONVERSION TO RECLAIMED WATER, ALL EXISTING IRRIGATION EQUIA1ENT 51-lALL BE MARKED NON-POTABLE A& NOTED: • EACl-4 EXISTING &FRAY 1-lEAD ON RISER 51-lALL 1-lAVE A RECLAIMED WATER WARNING &TICKER PLACED ON Tl-lE RISER (Cl-lRl&TY'& '<Z>tZ> RISER MARKER) • EACl-4 EXISTING FOF-UF &FRAY 1-lEAD 51-lALL 1-lAVE AN AFTER MARKET NON-POTABLE COVER INSTALLED (&EE ORIGINAL MANUFACTURER FOR MODEL NUM6ER). IF NONE AVAILABLE, Tl-lE TOP OF EACl-4 &FRAY 1-lEAD BODY 51-lALL BE FAINTED PURPLE • EACl-4 EXISTING VALVE 51-lALL BE TAGGED WITl-4 A RECLAIMED WATER WARNING TAG (Cl-lRl&TY'& -tD-MAX-F2-RCOO~) &EE 51-lEET T-2 FOR ADDITIONAL RECLAIMED WATER &IGNAGE NOTE& TO PROTECT OUTDOOR EATING AREA& FROM CONT ACT WITl-4 RECYCLED WATER, USE FLOOD BUBBLER& IN RAISED PLANTER&. IN EXISTING PLANTING AREA& ADJACENT TO OUTDOOR EATING AREA&, REPLACE EXISTING NOZZLE& WITl-4 VARIABLE ARC, LOW TRAJECTORY, NOZZLE& (RAINBIRD 12' VAN NOZZLE&) EXISTING REMOTE-~ CONTROL VALVE TO REMAIN (TYPICAL SYMBOL) 3/. ' ¾" ® .o.c. A EXISTING PLANTING AND IRRIGATION TO REMAIN (TYPICAL SYMBOL). MODIFY/ REPAIR IRRIGATION &FRAY 1-lEAD LAYOUT A& REQUIRED TO PROVIDE COMPLETE WATER COVERAGE TO Tl-lE ENTIRE PLANTER AREA. &EE IRRIGATION &FRAY! ~TOR 1-lE 6-D L GEN FO~ REFLAC ME T INOZZ ,ES. COUPLER, TYPICAL SYMBOL ADD NEW REMOTE CONTROL VALVE TO EXI TING VALVE MANIFOLD ... I I I I I I I I I I I I • CONSTRUCTION KE'r NOTES: 0 FOINT OF CONNECTION TO EXISTING IRRIGATION MAINLINE WITl-4 NEW &cl-lEDULE 4"' PVC MAINLINE (SIZE FER FLAN) AFFROXIMATEL Y Wl-lERE 51-lOWN. CUT AND CAP EXISTING IRRIGATION MAINLINE UPSTREAM OF POINT OF CONNECTION. CONTRACTOR 51-lALL VERIFY Tl-lAT NO OTl-lER CONNECTION& EXIST BETWEEN EXISTING DOMESTIC WATER MAINLINE AND ANY IRRIGATION MAINLINE. &EE ADDITIONAL "EXISTING POTA6LE WATER" NOTE&, Tl-4I5 51-lEET. 0 FOINT OF CONNECTION TO EXISTING IRRIGATION MAINLINE WITl-4 NEW Jv2" &Cl-lEDULE 4tZ> PVC MAINLINE <FIELD VERIFY EXACT LOCATION). ©CONTRACTOR 51-lALL VERIFY EXISTING &FARE WIRE& AT Tl-lE END OF MAINLINE RUN&. IF NO &FARE WIRE& EXIST, CONTRACTOR 51-lALL . INSTALL AND ADD NEW VALVE "A4" TO EXISTING VALVE MANIFOLD AND TO Tl-lE IRRIGATION CONTROLLER VIA Tl-lE "QUICK LINK" BY REED'& IRRIGATION SERVICE&, INSTALL FER MANUFACTURER'& INSTRUCTION& AND DETAIL 1-4/ Ll-4. VERIFY Tl-lAT Tl-lE EXISTING VALVE 1-lA& TWO GOOD FOWER WIRE&, A 1-lOT WIRE AND A COMMON WIRE. INSTALL NEW VALVE A4 ON MANIFOLD WITl-4 EXISTING VALVE AFFROXIMATEL Y Wl-lERE 51-lOWN ON FLAN. CONTRACTOR 51-lALL BE PREPARED TO TRENCl-4 BACK TO Tl-lE IRRIGATION CONTROLLER WITl-4 CONTROL WIRE IN Tl-lE EVENT Tl-lAT Tl-lE VALVE CANNOT BE ADDED TO Tl-lE VALVE SEQUENCE USING Tl-lE "QUICK LINK". 0 EXl&TING IRRIGATION CONTROLLER (LOCATION TO BE FIELD VERIFIED) TO BE SALVAGED AND RETURNED TO OWNER. PROTECT IN PLACE EXISTING CONTROL WIRE&, MAKE END& WATERPROOF, TAPE AND LABEL AND PLACE INSIDE VALVE BOX FOR FUTURE CONNECTION TO NEW CONTROLLER. ©CONTRACTOR 51-lALL TRENCl-4 AND INSTALL NEW MASTER VALVE WIRE AND FLOW &ENSOR CABLE (IN Jv2" CONDUIT) FROM NEW CONTROLLER LOCATION TO NEW MASTER VALVE AND FLOW &ENSOR LOCATION. 0 EXl&TING VALVE LOCATED IN NEW CONSTRUCTION AREA, AFFROXIMATEL Y Wl-lERE 51-lOWN, TO BE REMOVED AND REPLACED WITl-4 NEW VALVE. REFER TO KEYNOTE rt FOR INSTRUCTION& ON SYSTEM REPAIR. 0 CONNECT NEW VALVE, MENTIONED IN PREVIOUS KEYNOTE l!E>, TO EXISTING SYSTEM AND MODIFY/ REPAIR A& REQUIRED TO PROVIDE CONTINUED AND COMPLETE IRRIGATION SERVICE TO Tl-lE EXISTING PLANTER. ©CONTRACTOR 51-lALL PROTECT IN PLACE ALL EXISTING PLANTING AND IRRIGATION TO REMAIN. ANY PLANT MATERIAL OR IRRIGATION DAMAGED DURING CONSTRUCTION 51-lALL BE REPLACED BY Tl-lE CONTRACTOR AT NO ADDITIONAL COST TO Tl-lE OWNER. 0 5AWCUT AND REMOVE A&Fl-lALT PAVING A& REQUIRED TO INSTALL IRRIGATION MAINLINE, (2) 4" &FARE SLEEVE& AND WIRE CONDUIT. ;;:::\EXISTING REMOTE CONTROL VALVE& TO REMAIN 51-lALL PROVIDE \'.J CONTINUED IRRIGATION SERVICE. VERIFY Tl-lAT EXISTING VALVE& ARE DOWNSTREAM OF MAINLINE CAP PRIOR TO CUTTING AND CAPPING Tl-lE MAINLINE. MODIFY/ REPAIR A& REQUIRED FOR CONTINUED SERVICE. PRESSURE LOSS CALCULATION: PROJECT ViaSat POC#IRCV# A I 1 I ' POC WATER TYPE POT ABLE WATER ' RCVOEMAND 24 GPM HYORAUUC GRADE LINE ' 550 FEE METER ELEVATION 200 FEEl PRESSURE AVAIL.MLE AT POC . I ' 151.55 PSI (BJ EQUIPMENT LOSSES I # GPM SIZE LNGlHIQTY.I PSI LOSS (1) SERVICE LINE 24.00 'I:' 35.00 I 0.86 0.23 PSI (21 METER 24.00 1" 3.40 PSI 131 WYE FILTER, PRESS. REG. 24,00 1-1/'l:' 7.50 PSI l'I BACKFLOW DEVICE WI STRAINER 24.00 1-1/2" 13.00 PSI (5) FLOW SENSOR 24.00 1-1/2" 0.50 PSI (6) MASlER CONlROL VN..VE 24.00 1-1/2" 0.67 PSI (7) MAINLINE (314"-11/2" Sch. 40) 24,00 1 112" 150.00 1.51 2.27 PSI (81 MAINLINE (2"-3" CLASS 315) 24,00 NIA 60.00 0.50 0.30 PSI (9) ISOLATION VN..VES VJ/El. • LINE 3 0.70 2.10 PSI 1101 RCV SINGLE STATION 24,00 1 1/2" 3.60 PSI 1111 Sch. 40 LAlERALS 110% OF PSI REQ'Dl VJ/El. 3.00 3.00 PSI 1121 SUBTOTAL ' 36.57 PSI (13)+ 10% FOR FITTINGS : 3.86 PSI TOlN.. EQUIPMENl LOSSES . I I 40.22 PSI I (CJ ELEVATION GAINS /LOSSES I (1) ELEV. HEAD GAIN FROM SPRINKLR I 3 J FEEl• -1.30 PSI 121 ELEV. HEAD LOSS FROM SPRINKLR I 0 I FEET-= 0.00 PSI 101 N.. ELEVAllON GAIN/ LOSS -1 .30 PSI (DJ CAL CUL.A TIONS I I 111 TOTAL LOSSES I : 38.92 PSI 12\SPRINKLER OPERATING PRESSURE . ' 30.00 PSI (3) PRESSURE REQUIREMENl (D1 +D2 I 68.92 PSI ('I EXISl. STAllC PRESSURE (P.0.C.) I 151.56 PSI 151 RESIDUAL PRESSURE 119.88% 82.63 PSI I (E) PUMP REQUIREMENT (IF NEEDED) 111 TOTAL PUMP OUTPUT IIF REQ'D.I I I NIA PSI 121 SURPLUS (MIN. 10% 110 PSI REQ'D) iE1-D3) I 0.00% NIA PSI (F) PSI REGULA TDR SETTINGS 111 POC PSI REGULAlOR SElllNG rsurplua• 11.08 PSI OR I 16.07% .. I .. I PSI (2) RCV PSI REGULATOR SETTING I I 40.26 I PSI NORTH A OALIPO.NIA oo•Po•ATION MW PELTZ+ ASSOCIATES LANDSCAPE ARCHITECTURE SOLANA BEACH, CALIFORNIA 858.481 .0888 / RLA 2010 APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. IRRIGATION NOTES: I. EXISTING IRRIGATION INFORMATION 15 BASED ON CONSTRUCTION DOCUMENT& BY PETER A. LENDRUM ASSOCIATE&, DATED JULY I, 1'311 AND FIELD WORK CONDUCTED 6Y MWFA. CONTRACTOR 51-lALL FIELD VERIFY EXISTING IRRIGATION SYSTEM FOR ACCURACY. 2. &EE 51-lEET& Ll-3 Tl-lROUGl-4 Ll-1 FOR IRRIGATION EQUIA1ENT &Cl-!EDULE, NOTE&, DETAIL& AND ADDITIONAL INFOFc:MATION. 3 . VERIFY VALVE LOCATION& IN Tl-lE FIELD WITl-4 OWNER'& AUTOORIZED REPRESENTATIVE PRIOR TO COMMENCING WORK. 4. LATERAL LINE& ARE 51-lOWN WITl-llN PAVING FOR CLARITY ONLY, ACTUAL LOCATION TO BE WITl-llN PLANTER. CONTRACTOR 51-lALL CONFIFc:M ALL LAYOUT IN FIELD WITl-4 OWNER'& AUTOORIZED REPRESENTATIVE PRIOR TO COMMENCING WORK. !:>. MAINLINE 51-lOWN WITl-l!N PAVING FOR GRAFl-llC CLARITY ONLY, ACTUAL MAINLINE LOCATION TO BE A MINIMUM OF 18" OFF ADJACENT 1-lARD&cAFE AND OTl-lER OBSTACLE&, TYF. 6. IRRIGATION SYSTEM& ARE TO BE INSTALLED A& 51-lOWN IN Tl-lE DETAIL& AND SPECIFICATION&. CONTRACTOR 51-lALL BE RESPONSIBLE TO COMFL Y WITl-4 LOCAL CITY, COUNTY, AND ST ATE REQUIREMENT& FOR BOTl-4 EQUIA1ENT AND INSTALLATION. 1 . IRRIGATION SYSTEM& ARE TO BE INSTALLED A& 51-lOWN IN Tl-lE DETAIL& AND SPECIFICATION&. CONTRACTOR 51-lALL BE RESPONSIBLE TO COMPLY WITl-4 LOCAL CITY, COUNTY, AND &TATE REQUIREMENT& FOR BOTl-4 EQUIA1ENT AND INSTALLATION. 8. CONTRACTOR 51-lALL ADJUST ALL 1-lEAD& A& REQUIRED TO ACCOMMODATE ANY VERTICAL OBSTRUCTION& Tl-lAT MAY OCCUR, INCLUDING BUT NOT LIMITED TO LIGl-lT POLE&, FIRE 1-lYDRANT&, ETC. VERIFY ALL 1-lEAD LAYOUT WITl-4 OWNER'& AUTOORIZED REPRESENTATIVE PRIOR TO COMMENCING WORK. '3. FULL (2) &FARE CONTROL WIRE& AND Tl-lE COMMON WIRE FROM CONTROLLER TO ALL NEW MAINLINE END RUN&. LOOP IN ALL NEW REMOTE CONTROL VALVE BOXES ALONG NEW MAINLINE RUN. MAKE WIRE END& WATERPROOF, TAPE AND LABEL A& "&FARE WIRE&", AND PLACE IIZ>' COIL INSIDE VALVE BOX, TYPICAL. ltZ>. CONTRACTOR 51-lAL PROTECT IN PLACE ALL EXISTING PLANTING AND IRRIGATION TO REMAIN. ANY PLANT MATERIAL OR IRRIGATION DAMAGED DURING CONSTRUCTION 51-lALL BE REPLACED BY Tl-lE CONTRACTOR AT NO ADDITIONAL COST TO Tl-lE OWNER. II. CONTRACTOR 51-lALL VERIFY FLOW& FOR ALL EXISTING REMOTE CONTROL VALVE&. UPON REPLACING &FRAY 1-lEAD BODIE& AND NOZZLE&, CONTRACTOR 51-lALL VERIFY Tl-lAT NO ZONE EXCEED& A MAXIMUM FLOW OF 32 GALLON& FER MINUTE. VALVE& 1-lAVING FLOW& LARGER Tl-lAN 32 G.F.M. ARE EXCEEDING Tl-lE MAXIMUM SAFE FLOW (!:> FEET FER SECOND) Tl-lROUGl-4 &cl-lEDULE 4tZ> PVC MAINLINE. CONT ACT LANDSCAPE ARCl-llTECT FOR DIRECTION ON 1-lOW TO PROCEED. 12. REFER TO IRRIGATION &FRAY 1-lEAD AND ROTOR LEGEND FOR &ELECTION OF REPLACEMENT &FRAY, ROTOR& AND NOZZLE&. REMOTE CONTROL VAL VE CALLOUT: STATION SEQUENCE VALVE SIZE KEY MAP t .rmmn=rrm=mn=rrm=mrr~i'rini'rin~=-::"P"--....,7"' 0 10 20 SCALE: 1 "=20' 40 PROJECT SITE l ··••>•••<·.·····• f.·. . J .. r •».·.· t U-2 l <. •··· 1 ·.· .. J. 60 L • Ll-1 1 1E·. ~'::'::':'::'=:~~~:':':':':':'::::""'_:1,....-/.i L --~--~:~.-~-~--~--~:.;_;.-~ "AS BUILT" TllLE REVIEWED BY: INSPECTOR DATE DATE z <( ...J a.. z 0 ~ (9 -a::: a::: Ll-2 CARLSBAD MUNICIPAL WATER DISTRICT A.-o Golt eow.. Q VICINITY MAP NORTH NOTTO SCALE SHEET CITY OF CARLSBAD 4 PLANNING DEPARTMENT PRIVATE (ONSITE) RECLAIMED WATER SYSTEM FOR: ViaSat Building 6 9 SHEETS DISTRICT APPROVED CHANGES CARLSBAD MUN I Cl PAL WATER DISTRICT '"'N'"'o"'T. ----=c:-D=-=Es:':c'=R1'=PT::::,IO::-:-N.,....-""'-''---....C..C-'r;-;AP~P::::R-:ccOVE=D,;::-DA7'TE;;:--j DEVELOPERS NAME: -----------6305 EL CAMINO REAL CARLSBAD, CALIFORNIA 92009 1---t-------------t----;----1 ADDRESS: _____________ l-------=--:----------------1 --APf2-0W( =· ~,, .LL WILLIAM E. PLUMMER R.C.E. 28176 DATE n~ ~ ~1-.,oJ:L DEPUTY CITY ENGINEER EXP.6/30/08 PLANNING TELEPHONE: SAN DIEGO COUNTY HEAL TH DEPARTMENT ORVIN BY: DN APPROVED BY: DATE DATE PLAN PREPARED: ________ _ f--+------------+----t---1 BY: CHCKO BY: MF PROJECT NO. PD07-09 5:.c,.•f:> DATE DRAWING NO. 455-4L IRRIGATION MAINLINE EQUIPMENT LEGEND SYMBOL DE5CRlPTION MANLFACTURER / MODEL • REMAf-Ke ~ Fi!ECLAIMED l,.IATEFc METEFc (C.M.l,.I.D. STD. Dl-!Gs. NO. 1-1-4) BY CARLSBAD MUNICIPAL WATER DEPT. APPROXIMATE LOCATION, SEE FLAN FOR SIZE. Tl-IE OWNER (FIRST INDUSTRIAL REALTY• TFi115TJ 51-1ALL COORDINATE AND PAY ALL ASSOCIATED FEES FOR Tt-!E INSTALLATION OF Tl-IE RECYCLED l,o,IATER METER BY Tl-IE CARLSBAD MUNICIPAL 1-!ATER DISTRICT c---POINT OF CONNECTION --POINT OF CONNECTION AFFROXIMATEL Y WI-IERE 5I--IOl,,,IN. VERIFY SIZE OF EXISTING: MAINLINE AND 1-!ATER PRESSURE PRIOR TO ORDERING! EQUIFMENT. 19 HALL MOUNT IRRIC:iATION CONTROLLER ASSEMBLY JOI-IN DEERE LANDSCAPES, GREENTECI-I COORDINATE FINAL LOCATION WITI-I OWNER'S AUTI-IORIZED DIVISION IICAl2-I-IUI-IE>/LPP/TRC-XREC/Re/ REPRESENTATIVE. CONTACT MICHAEL FACON, JOI-IN DEERE LAND5CAPES (GREEN TECI-I DIVISION) FOR CONTROLLER I-IFC-I51Z'/MVP /SPT-24 &PECIFICS (8flXl>) 421-l'Z>11~ V MASTER VALVE SUPERIOR .321'Z)1Z>-lv2" (NORMALLY CLOSED> APPROXIMATE LOCATION, SEE PLAN FOR SIZE ..E FLOW SENSOR 1-11.JNTER FLOW-CLIK -I½" INSTALL PER MANUFACTURER'S RECOMMENDATION. INCLUDED AS PART OF CONTROLLER ASSEMBLY PART NUMBER FS FLOW SENSOR CABLE IN CONDUIT PAIC:JE F-11E>2P INSTALL IN CONDUIT, FER MANUFACTURER'S REC0Mt-1ENDATION NO SYN. RAIN SENSOR 1-11.JNTER MINI -CL IK RAIN SENSOR WILL 6E INCLUDED AS FART OF CONT!'WLLER ASSEMBLY. REFER TO CONTROLLER MODEL NUMBER, ABOVE NO SYN. &TAINJ..ESS STEEL CONTROLLER ENCLOSURE Y.I.T. STRONGSOX SB-24S5J,,,1 PROVIDE KEY LOCKS AND LOCKS TO SECURE ENCLOSURE. REFER TO CONTROLLER MODEL NUMBER, ABOVE [g] I21Z' VOLT ELECTRICAL POWER --PROVIDED BY ELECTRICIAN. VERIFY ACTUAL LOCATION IN FIELD B BACKFLOW DEVICE FEeco 82SY-I½' IIZ) FOOT MINIMUM 1-!0RIZONTAL DISTANCE FROM POTABLE (C.M.1-1.D. STD. DJ,,IG. NO. W-21'Z>) WATEFe MAINLINE. COORDINATE EXACT LOCATION HITI-I OWNER'S AUTHORIZED REPRESENTATIVE NO SYN. BACKFLOW PREVENTER ENCLOSURE V.I.T. STRONGBOX SB-4SSS PROVIDE CONCRETE PAD PER DETAIL NO SYN. CONCRETE BASE FOR BACKFLOW PREVENTER --PROVIDE CONCRETE PAD AS REQ'D. COORDINATE FINAL LOCATION W/ OWNER'S REPRESENTATIVE. NO SYM. PRESSURE REGsULATOR/ HYE STRAINER WILKINS srzw YSBR -I½" PRESSURE SETTING: AND SIZE AS NOTED FER Tl-IE FLAN l.)(j BRONZE GATE VALVE (MAINLINE ISOLATION) NIBCO T-11.3K LINE SIZE FOR MAINJ..INE ISOLATION E0 BALL VALVE (VALVE ISOLATION) KINC:s BROS. 6TU SEFelES LINE SIZE FOR VALVE ISOLATION REMOTE CONTROL VALVE RAINelRD XXX-PE6-PRS-D-NP-I-IAN APPROXIMATE LOCATION. SEE FLAN FOR SIZE. @ QUICK COUPLER VALVE NELSON 1E>4S -I" VERIFY ACTUAL LOCATION IN FIELD ---NON-POT ABLE, PURPLE, PYC PRESSURE FIFE Pl-I PIPE OR EQUAL PVC CLASS .315 FOR 2' AND LA~ER (MAINLINE) PVC 5CH 41'Z> FOR 1-1/2" AND SMALLER NON-POT ABLE, FURPLE, PYC NON-PRESSURE PIPE Pl-I PIPE OR EQUAL PVC 5CI-I CL 2 cZ>l'Z> <LATERALJ ---PRESSURE PIPE SLEEVE Pl-I PIPE OR EQUAL PVC 5CI-I. 8(1), 2X DIA OF SLEEVED PIPE MIN. -NON-PRESSURE PIPE SLEEVE PW PIPE OR EQUAL PVC 5CI-I. 8(1), 2X DIA OF SLEEVED PIPE MIN. ------WIRE CONDUIT PW PIPE OR EQUAL PVC 5CH. 8(1), 2X SIZE OF WIRE 6UNDLE NO SYM. WIRE CONNECTOR SPEARS DRI-SPLICE FOR ALL 1-!IRE SPLICES BELOW GRADE ~ 1-!IRE SPLICE PULL eox --PULL BOXES FOR 1-!IRE SPLICES SI-IALL 6E LOCATED APPROXIMATELY StZW' O.C. AND AT THE ENDS OF ALL SLEEVES UNDER PAYING:. PULL BOXES SI-IALL 6E IIZ'" ROUND HITI-I LOCKING: LID ~ SPARE WIRE PULL BOX -END PULL BOXES FOR 1-!IRE SPLICES SHALL 6E LOCATED AT Tl-IE END OF ALL MAINLINE RUNS AND HEAT BRANDED t,,,.IITI-I "EP6". PULL BOXES SI-IALL BE ll'Z>" l'WUND WITH LOCKING LID NO 5YM. IRRIGATION CONTFeOL 1-!IRE DIRECT BURIAL, 14 GAUGE 6tZWY, TYPE UF, UL APPROVED . 5J,,,IING: CHECK VALVE HAMMOND IB~41'Z> LINE SIZE 6Y LATERAL LINE, INSTALL DOWN5TREAM OF EACI-I " RCY 1-ll-lEN RCY 15 LOWER TI-IAN Tt-!E &FRINKLER I-IEADS ® RECYCLED 1"1ATER 'DO NOT DRINK' SIGN CHFelSTY SEE PLAN FOR FUTURE LOCATIONS. CONTRACTOFe TO PROVIDE MOUNTING-I-IARDWARE FOR FUTURE INSTALLATION NO SYM. NON-POTABLE VALVE I.D. TAG: CI-IRISTY INSTALL INSIDE OF ALL VALVE eoxes NO SYM. VALVE eox CARSON-6ROOK5 SEE SPECIFICATIONS FOR SIZES r'>, ,7! EXISTING FOT.oeLE J,,IATER METER TO REMAIN PROTECTED IN Fl.ACE --FIELD VERIFY EXACT LOCATION ., ' ~ ~ EXISTING eACKfLOW DEVICE TO FcEMAIN I ~CTED IN PLACI FEeco 82!:>Y -2' FIELD VEFelFY EXACT LOCATION , >< ' -----EXIST~ IRFclGATla.l MAINLINE TO REMAIN F!'WTECTED IN Fl.ACE --FIELD VERIFY EXACT LOCATION I". EXISTING REMOTE CONTROL VAL.YE TO REMAIN PROTECTED IN PLACE FIELD VERIFY EXACT LOCATION ~ EXISTING: REMOTE CONTROL VALVE TO SE REMOVED -SEE KEYNOTE~ FOR MORE INFORMATION NO SYM. VALVE REPAIR KIT REED'S IRRIGATION SERVICE, QUICK LINK INST ALL PER MANUFACTURER'S INSTRUCTIONS NO SYM. CONCRETE TI-IRUST BLOCKS -AT ALL MAINLINE DIRECTIONAL CI-IANG-ES ::Cx ;;·· D>°' EXISTING DCt1ESTIC l-4ATEFi? MAINLINE TO r:;IEMAIN PROTECTED IN PLACE --FIELD VERIFY EXACT LOCATION lM EXISTING DCME5TIC WATER METER TO liia1AIN PROTECTED IN Fl.ACE -FIELD VERIFY EXACT LOCATION -----f:X 8" =:tf.£ ---EXISTING Fllli:E SEFi?YICE MAINLINE TO REMAIN FllilOTECTED IN Fl.ACE FIELD VERIFY EXACT LOCATION lf_!R[1 EXIST!t6 Fllli:E SERVICE HETER TO lli:EMAIN PROTECTED IN Fl.ACE -FIELD VEFelFY EXACT LOCATION l><>< EXISTING Fli.£ 1-IYDR.ANT TO FcEMAIN PROTECTED IN PLACE --FIELD VERIFY EXACT LOCATION 0 EXISTINC:s VALVE TO REMAIN FFeOTECTED IN PLACE --FIELD VERIFY EXACT LOCATION IRRIGATION 5FRAY ~EAD LEGEND SYH60L SPRAY HEAD DESCRIPTION MANUFACTURER / MODEL • RADIUS PSI EST SST .3E,IZ) 18"' (21'Z) 9"' VAN ~ □ El □ rill 12' SI-IFi116 FOP-UP SJ:88Y HEAD RAIN 61 I812-SAM-FRS WI 10 SE~ES NOZZLE • l~P cover; ll'Z>' 31Z) ~ E3 B !SJ i;;i 12' St-!FeUB POF-UI=' e,-•y Ar'.l RAINP.I I6I2-SAM-WI e SEFclES NOZZLE 4 l~F COYEFc 8' .31Z) 8 B ~ 12' St-!RUB POP-UP SPRAY I-IEAD RAINBIFcD I8I2-SAM-FRS WIS SEFclES NOZZLE • ll30!ZINF COYEFc S' 'v ., 12' St-!Fi116 POP-UP SPRAY I-IEAD RAIN 6IFi?D I6I2-SAH-PRS 1-414-YAN SERIES NOZZLE• I~ COV!:R 4' .3e, • FLOOD 61.lBBLEFe RAIN6IRD PA-85-NP --.31Z) IRRIGATION ROTOR LEGEND SYMBOL SPRAY I-IEAD DESCRIPTION MANUFACTURER I MODEL • ~ 18"" .36"- CD @ ® E>" 51-1RUB FOP-UP FeOTOR 1-!UNTEFe l-2cZ>-6P-ARV/3RY-.5/I.IZl/2.cZ> SR E>" TURF ROTOR I-IEAD @ @ @ E>" SI-IRUB POP-UP FeOTOR HUNTER l-21Z'-6P-ARV/.3RV-.1S/I.S/3.cZ> SR E>" TUFi!F !'WTOR HEAD G) @ ® E>' SHRUB POP-UP ROTOR I-IUNTEFe I-2cZ>-E>P-AFeV/.3FeV-l.cZ>/2.cZ>/4.IZI E>" TUFi!F ROTOFe t-!EAD @ ® ® E>' St-!FeUB POP-UP ROTOR I-IUNTER l-21Z1-6F-ARV/.3RV-I.S/::!>.iZ>/6.cZ> E>" TUFi!F ROTOFe I-IEAD @ @ @ E>' St-!RUB POP-UP ROTOFe 1--ll.t-lTEF/: l-21Z1-E>P-ARV/3RY-2.IZl/4.cZ>/8.l'Z> E>" TUFi!F FeOTOR I-IEAD IRRIGATION SPRAY AND ROTOR NOTES: ABBREVIATIONS: I. GFM SI-IOWN AT UNADJUSTED FULL FLOW 2. ADJUST SPRAY TO SUIT SITE CONDITIONS. RAD.a RADIUS ADJ.= ADJUST ABLE GALLCNS PER MINUTE EST 55T .3E>IZ> 18"' I21'Z> ~ YAN IN/I-I"- I.S8 .1':I .53 .3':I vARI LE, 1.cZ>S .S2 .3S .2E> VAf. LE> .41 .2IZI .1.3 .(l'Z) LE> ·"'"' . .31 VARI VAR IZl.2E RADIUS PSI GALLONS PER MINUTE (FEETJ '3et 18"" .3E>l2: 16-18 Sl'Z> IZI .!:> (.l'Z) 2.cZ> 19-25 Sl'Z) .15 1.S 3.IZ> 26-.31'Z) Sl'Z) 1.2 2.cZ> 4.2 .31-.35 ScZ> l.l'Z) .3.IZ> 6 .l'Z> 36-4IZI ScZ> l.(Z) .3 .l'Z> E, ·"' DETAILS D/Ll-1 C/Ll-4 A/Ll-4 F/Ll-4 D/Ll-4 D/Ll-4 B/Ll-4 A/Ll-4 -- 1-1/LI-S I/LI-E> I/LI-E> -- E/Ll-4 G/Ll-4 D/Ll-5 D.E/LI-S E/LI-S F/LI-S A/LI-S A,6/Ll-1 A/LI-S D/LI-S A/LI-S A/Ll-5 6/Ll-5 D/LI-E> D/Ll-6 D/LI-E> -- F/Ll-6 T-2 C/LJ-1 E/Ll-5 C/LI-!:> ---- ------ -- A/Ll-4 ---- -- -- ---- DETAILS B/Ll-6 B/Ll-6 6/Ll-6 6/Ll-6 6/Ll-6 DETAILS G:/LI-S G/LI-S G/Ll-5 G/LI-S G/LI-S IRRIGATION NOTES I. THESE SYSTEMS ARE DESIGNED TO SUPPLY A MINIMUM OF .30 PSI AT Tl-IE SPRINKLER I-IEAD AND 4"' PSI AT THE ROTOR HEAD WITI-I A MINIMUM OF 152 PSI STATIC 1"1ATEFe PRESSURE AVAILABLE AT THE POINT OF CONNECTION. REFER TO CIVIL DJ,,IGS AND IRRIGATION PLANS FOR LOCATION OF F.O.C. -FIELD VERIFY AS REQUIRED. 2. OBTAIN A STATIC WATER PRESSURE READING AT THE POINT OF CONNECTION PRIOFe TO ORDERING: ANY IRFelGATION MATEFelALS AND PROCEED INC:! WITH INST ALLING: IRRIGATION SYSTEM. IF Tl-IE WATER PRESSURE FOUND IS DIFFERENT TI-IAN SI-IOI-IN ON PLAN6, CONTRACTOR SI-IALL CONT ACT Tl-IE LAND5CAPE ARCHITECT FOR FURTl-!ER INSTRUCTIONS. IN THE EVENT PRESSURE DIFFERENCES ARE NOT f<EPORTED PRIOR TO START OF CONSTRUCTION, THE IRRl6ATION CONTRACTOR SHALL ASSUME FULL RESPONSl6ILIT'r' FOR ANY REVISIONS, AND COSTS ASSOCIATED l"tlTH SAID REVISIONS. .3. VERIFY EXACT LOCATION OF ALL UNDE~OUND UTILITIES AND ABOVE GROUND OBSTACLES WITt-!IN Tl-IE 1"10RK AREA PRIOR TO START OF CONSTFWCTION. IF A CONFLICT EXISTS BETWEEN OBSTACLES AND Tl-IE Fl'WPOSED WORK, CONTRACTOR SI-IALL PROMPTLY NOTIFY LANDSCAPE ARCt-!ITECT TO AFeRANG:E FOFe RELOCATIONS, IF REQUIRED, PRIOR TO START OF CONSTFWCTION. 4. INSTALL 51-iUT-OFF VALVES, QUICK COUPLING-VALVES, AND REMOTE CONTROL VALVES ADJACENT TO PAVEMENT AND PEDESTRIAN PATI-IS 1-ll-lEFeE OCCURRING: <12" MAXIMUM FFeOM SUCI-I EDG:ESJ IN PLANTING: AREAS. S. SYSTEMS St-!ALL BE INSTALLED AND ADJUSTED TO KEEP APPLIED WATER AND RUNOFF OFF OF ALL FAYING, WALKS AND OTI-IER NON-INTENDED AREAS AT ALL TIMES. TI-IIS 51-1ALL INCLUDE Tl-IE SELECTION OF Tl-IE BEST DEGREE ARC TO FIT Tl-IE SITE CONDITIONS AND ADJUSTING Tl-IE FLOW CONTROL STEM AT EACH REMOTE CONTROL VALVE TO OBTAIN Tl-IE OPTIMUM OPERATING: PRESSURE FOR TI-IAT SYSTEM. E>. LOW I-IEAD DRAINAGE, HI-IERE OCCUFeS, SI-IALL 6E STOPPED USE 1-!ITH Tl-IE OF SPRING CI-IECK VALVES. SPRING: CI-IECK VALVES SI-IALL BE INSTALLED ON Tl-IE RISER ASSEMBL 'I' OF Tl-!E SPRINKLER Wl-!ERE LOW I-IEAD DRAINAGE OCCURS. 1. ALL LATERAL LINE ENDS SI-IALL BE SIZED .3/4" UNLESS SI-IOWN OTHERI-IISE. 8. ALL IRFelGATION LINES UNDER PAVING AND THFeOUGt-4 WALLS, FOOTINGS, ETC. SHALL eE SLEEVED WITI-I 5CI-I 8"' PVC PIPE. SLEEVE SI-IALL 6E 2 TIMES THE DIAMETEFe OF THE PIPE TO BE SLEEVED, MINIMUM. IT IS THE RESPONSIBILITY OF Tl-IE CONTRACTOR TO COORDINATE Tt-!E INSTALLATION OF SLEEVING-1"1ITI-I OTI-IEFe TRADES. ~-UPRIGHT GROWING SHRUBS SHALL BE PLANTED NO CLOSER THAN 3 FT. FFeOM SPFelNKLEFe I-IEADS, FROM SPRINKLER I-IEAD TO OUTSIDE EDGE OF SI-IFeUB FOLIAGE. ll'Z>. ALL SPFelNKLER I-IEADS SI-IALL 6E ADJUSTED AS REQUIRED, AS TO HEIGi-iT, COVERAC:JE PATTERN, OFe SPFelNKLER HEAD ORIENTATION, SO AS NOT TO ALLOW BLOCKAGE OF SPRAY PATTERN 6Y PLANT MATERIAL, OR MISALIGNED COVERAC:JE PATTERN Tl-!AT MAY CAUSE PLANT DECLINE OR DEMISE. II. ALL PLANTINGS SI-IALL BE FULLY 1"1ATERED-IN uPON PLANTING:. DO NOT RELY SOLELY UPON Tl-IE SPRINKLER &'!'STEM. UTILIZE SUPPLEMl=NTAL I-IOSE WATEFelNG: AS REQUIRED, INITIALLY AND DURING Tl-IE PLANT EST A6LISt4MENT PEFelOD, TO ENSURE ALL PLANTINGS RECEIVE ADEQUATE WATER TO THE ENTIRE ROOT ZONE. 12. IRRIGATION SYSTEMS ARE TO BE INSTALLED AS SI-IOI-IN ON PLANS AND IN ACCORDANCE 1-!ITI-I Tl-IE CRITERIA AND ST AND ARDS OF Tl-IE LAND5CAPE DEVELOFMENT MANUAL AND OTI-IEFe AF'FLICA6LE STANDARDS AS OF THE APPROVED DATE OF TI-IESE PLAN5. 13. USE TWO WRAPS OF TI-IREE-QUARTER INCH (314') TEFLON TAPE FOR ALL TI-IREADED CONNECTIONS. 14. ALL SPRINKLER I-IEADS SHALL BE SET PERPENDICULAR TO Tl-IE FINISI-I GRADE OF Tl-IE AREA TO 6E IFcRIGATED UNLES5 DESIGNATED ON THE FLANS. ADJUST Tl-IE ANGLE OF FelSERS FOFe SPRINKLEFe I-IEADS ON SLOPES FOR OPTIMUM COVERAGE AND MINIMUM OVERTI-I~ OF SPFclNKLEFe I-IEADS. 14. ALL SPRINKLER 1-IEADS SI-IALL BE SET PERF'ENDIOJLAR TO THE FINISI-I GRADE OF Tl-IE AREA TO eE IFcRIGATED UNLESS DESIGNATED ON Tl-IE FLANS. ADJUST THI= ANGLE OF RISEFeS FOFe SPRINKLER I-IEADS ON SLOPES FOR OPTIMUM COYEF¥--E AND MINIMLN OVERTJ.iR01"1 OF SPRINKLEFe HEADS. IS. Tl-IE CONTFcACTOR SI-IALL NOT 1-!ILLFULL Y INST ALL Tl-IE SPRINKLER SYSTEM AS SHOWN ON Tl-IE DFeA1"1ING:S Wl-iEN IT IS OBVIOUS IN THE FIELD Tl-iAT 06&TRUCTIONS, GRADE DIFFERENCES OR AREA DIMENSIONS EXIST TI-IAT MIGi-iT NOT I-IAYE SEEN KNOI-IN DURING: THE DESIGN. eLJCI-I 065TRUCTIONS OR DIFFERENCES SI-IALL BE BROUGHT TO THE ATTENTION OF Tl-IE LANDSCAPE ARCI-IITECT. IN Tl-IE EYENT THIS NOTIFICATION IS NOT FEF/:F~ !ED, THE CONTFcACTOR SI-IALL 6E RESPONSIBLE FOR ANY REVISIONS NECESSARY. IE>. MONITOR Tl-IE AUTOMATIC CONTFeOLLER SCHEDULING: CAREFULLY DURING: Tl-IE MAINTENANCE PERIOD AND ADJUST Tl-IE RUN TIMES ACCORDING:L y so TI-IAT ALL AREAS RECEIVE ADEQUATE euT NOT EXCESSIVE MOISTURE. SHORT SETS 1"1ITH REPEAT CYCLES ARE PREFERRED TO SINC:sLE L~ SETS OF FcLIN TIMES. ADJUST ST ART TIMES TO ALLOl"1 A MINIMUM OF ONE <IJ I-IOUFe 6ETl"1EEN REPEAT CYCLES. EXTEND DAYS 6ETI-IEEN 1"1ATEFelNG: AS FAR AS PRACTICAL FOR Tl-IE SEASON. CHA.NC:sE l~IGATION Fi11N TIMES MONTI-IL Y TO MATCI-I EVAPOTFcANSPIRATION CONDITIONS. 11. PFeOvJDE T!-10 LAYEFeS OF DETECTABLE I-IAFa'-!INC:s TAPE FOFe ALL MAINLINE <PRESSURE PIPE) FWNS. 18. PROVIDE 18' <MIN.J COVER OVER ALL IFeFclGATION CONTROL WIRES RUNNING: SEPARATELY FFeOM MAINLINE. 19. THE CONTRACTOR SHALL 06TAIN THE PERTINENT EN6INEERING OR Afte.HITEC~ FLANS 13Ef'ORE BEGINNING mRK. 20. THE GONTAACTOR SHALL 06TAIN ALL NECESSARY PERMITS REG!UIRED TO PERFORM THE ~ INDICATED HEREIN BEFORE BEGINNIN6 ViORK. 21. THE IRFclGATION CONTRACTOR SHALL ADJUST THE P~SURE RE61.JLATOR ON EACH REMOTE CONTROL VALVE SO THAT THE SPRINKLER HEAD FARTHEST AND HIGI IEST IN E:LEVATION FROM ITS RE:SPEGTIVE CONTROL VALVE OPERATES 1/'llTHIN THE OPERATIN6 PRES5IJl<E SHOV'IN ON THE IRRIGATION LEGEND. NOT TO EXCEED (5) PSI ABOVE THE GIVEN OPERATING PRESSURE FIWM THE SPECIFIED PRESSURE: LOCATED ON THE HYDRAULIC CALCULATIONS. 22. CONTRACTOFe SI-IALL F'FeOTECT EXISTING IRRIGATION SYSTEMS ADJACENT TO Tl-IE CONSTRUCTION SITE TO THE MAXIMUM EXTENT POSSISLE. CONTFeACTOFe SI-IALL CUT AND CAP ANY EXISTINC:s IRRIGATION SYSTEMS ENTERING: Tl-IE WOFa< AREA AND MAKE THE NECESSARY MODIFICATIONS/ REPAIFeS TO F'FeOYIDE COMPLETE WATER COVERAGE TO EXISTING: PLANT MATERIAL. 2.3. ALL PVC MAINLINES SI-IALL BE SUBJECTED TO A PRESSURE TEST OF ~ PSI FOR A PEFelOD OF 4 I-IOURS AND SI-IALL 6E 1"1ATERTIG:I-IT. ALL CONTROL VALVES, AND SHUT-OFF YALYES SI-IALL 6E INSTALLED PRIOR TO TESTINC:s. ALL TRENCHES SI-IALL 6E OPEN AT TIME OF PRESSURE TEST. IFcRIGATION CONTROL I-IIRING: SHALL BE VISUALLY OBSERVED 6Y Tl-IE LANDSCAPE ARCI-IITECT . ...:.FFROYAL SI-IALL 6E RECEIVED SEFORE BACKFILLING: ANY TRENCI-I. DO NOT COVEFe ANY WIRES, LINES OR FITTINGS UNTIL THEY HAVE BEEN CI-IECKED AND APPROVED . 24. ADY. <ANTI DRAIN VALVE) UNITS AS SI-IOU.N IN Tl-IE DETAIL DRAWINGS ARE FOFe TYPICAL INSTALLATION ONLY, AND MAY NOT 6E REQUIRED ON ALL ..+EADS. PFelOR TO INSTALLATION Tl-IE CONTRACTOR SHALL YERIF'r WITI-I Tl-IE ON SITE C.RADES IF TI-IERE IS AN ELEVATION DIFFERENCE ct= 24" OR MOFeE BETWEEN Tl-IE I-IIGI-IEST I-IEAD AND LOLI.eST I-IEAD ON A SYSTEM, THE ADV. SI-IALL 6E INSTALLED FER DETAIL DRAWING:. 2&. FINAL AS-6UIL T DRAWINGS WILL BE REQUIRED TO eE REVIEWED AND ~VED 6Y Tl-IE CITY AND FINAL MYLARS WILL 6E REQUIRED TO 6E APPFeOVED AND Sic.NED er-THE CITY F'FelOR TO PLANNING: DEPAFtTMENT SIGrNING: Tl-IE PEi.MIT CARD. Cl) w ~ 0 z 0 z <( 0 z w C) w ....J z 0 - Ll-3 "AS BUILT" TITLE DATE REVIEWED BY: APPROVED FOR PLANTING 1--1_Ns_PE_cT_OR _______ oA_TE_---1 MW PELTZ + ASSOCIATES LANDSCAPE ARCHITECTURE SOLANA BEACH, CALIFORNIA 858.481.0888 / RLA 2010 ND IRRIGATION ONLY, CARLSBAD MUNICIPAL WATER DISTRICT INCLUDING PRECISE SH;ET CITY OF CARLSBAD 9 LOCATION OF PLANTING PLANNING DEPARTMENT SHEETS AREAS. PRIVATE (ONSl1E) RECLAIMED WATER SYSTEM FOR: ViaSa t Building 6 3. RADIUS REDUCTIONS ON SPRAY I-IEADS, WHERE REQUIRED, ARE TO 6E ACCOl"IPLISI-IED USING APPROPRIATE RAINelRD PCS SCREENS (AS DIRECTED BY LAND5CAPE ARCHITECT). VAN• YAFelA6LE ARC NOZZLE SAM• SEAL-A-MATIC Dl51RICT APPROVED CHANGES CARLSBAD MUN I Cl p AL WATER DI STRICT t-,-N"""O.-r----::-:DE=-=-sc""R""1r=110-:-,N,------,-,,AP""P=Ro""VE-=D:-r::D"'."A lE=i DEVELOPERS NAME: ----------6J05 EL CAMINO REAL CARISEIID. CN.JFORt.lA 92009 4. ALL NEl,,,I 51-1FeU6 SPRAY I-IEADS INSTALLED FAFeTI-IER Tt-!AN TEN (l(Z)) FEET FFeOM PAVING, RET AININCs 1"1ALLS, CUFeeS, SIDEWALKS, STEPS, TUF/:F 60UNDAFelES OR OTHEFe PEDESTFelAN AREAS MAY 6E INSTALLED AS A RAIN6IRD PA-85-NP 51-1Fi116 ADAPTER WITI-I Tl-IE NOZZLE AS SI-IOHN. S. ALL NEW FOP-UP SPRAY ..+EADS SI-IALL ..+AVE A RAIN BIRD NON-FOTA6LE lefl)l'Z> SERIES COVER (MODEL• IUlcZ> NP COVEFe) PRS-D= PRESSURE REGULATING MODULE ---DA \/ID A. HAUSER DA 1E DEPUTY CITY ENGINEER R.C.E.3;J061 EXP.6/30/0B SAN DIEGO COUNTY HEAL TI-I DEPAR1MENT APPROVED BY: DAlE 1--+------------l----ll----l ADDRESS: TELEPHONE: DATE PLAN PREPARED: _______ _ 1--+-------------<-------,1----1 BY: DR'MI BY: ct,CkO BY: 5--i.C>'t:) DATE PRO..ECT NO. DRAWING NO. PD07-09 455-4L - , }----t Q I al) ,,-----112 ~-2 r-----{8 6" HIN. , ............ 11 CD AUTOMATIC IRRIGATION CONTROLLER 0 SC+-! 41Zl PVC ELECTRICAL CONDUIT <SIZE AS Fi?EGl'D.) @ PLASTIC ELECTRICAL CONDUIT COUPLING @ CONCRETE PAD (4' THICK X 2' X 2') @ SIZl DEG. PLASTIC ELECTRICAL CONDUIT SHEEP (SIZE AS REGl'D.) @ STRUCTURAL WALL G) .3/4' EXTERIOR GRADE PL ..,..-wooD MOUNTING PLATE SECURED TO WALL 1,,1/4-1/4" DIA. ANCHOR 60L TS @ PROVIDE 3/4 " NOM. DIA. PLASTIC ELECTRICAL CONDUIT 1,,1/ IIS VAC POl,,IER <INDEP. 21Z>A CIRCUIT) @ SEE SPECS. FOR DEPTH @) PYC SC+-! 4(l) ELECTRICAL CONDUIT FOR RAIN SENSOR <SEE MFR'S INSTRUCTIONS FOR MOUNTING) @ CONTROL l,,IIRE BUNDLE, TAPED AT IIZ>' INTERVALS @ JUNCTION eox FOR RAIN SENSOR l,,IIRE NOTE, CONT ACT MICHAEL FACON, JOHN DEERE LAND5CAPES (GREEN TECH DIVISION) FOR CONTROLLER SPECIFICS (E¼!)IZ>) 421-IZ>119 0 WALL MOUNT CONTROLLER NO 5CALE ~--·~~ 4 . 0 0 PIIECTION OF i=L~ l ® ,, @ CD SENSOR CA6LE - EXTEND TO CONT~LLER 0 FOR FLOW SENSOR ® WHITE @ BLACK ® FINISI-I GRADE 0 FLOW SENSOR NO !!>CALE 4" MIN. • I --@ NOTE: I. BOX TO SE INSTALLED AS TO ALLOW FOR ~PER OPERATION OF 6ALL VALVE INSTALL AT RIG:I-IT ANGLE TO HARDSCAPE EDG:E, INSTALL VALVE OFF-CENTER IN BOX. 2. INSTALL VALVE eox EXTENSIONS AS REQUIRED TO ACHIEVE PROPER VALVE INSTALLATION AT MAIN LINE DEPTH. l@ l ® l '( 'l " G) ® ® @ ® @ SECTION • 'l SPLICE WIRE W/ WATE~ TYPE CONNECTIONS ~OVIDED VALVE eox LENGHT OF RUN EQUALS IIZ> TIMES PIPE DIAMETER FLOW SENSOR LENGHT OF RUN EQUALS 5 TIMES PIPE DIAMETER NO VALVES, REDUCERS, OR EL60WS IN TI-IIS AREA CD FINISHED GRADE IN TUFif' AREAS @) PURPLE, REC..,..-CLED WATER, PLASTIC RECTANGULAR VALVE eox l,,IITH BOLT DOI-IN COVER, USE STAINLESS BOLT, NUT, AND WASHER eox TO BE PLACED AT RIGHT ANGLE TO HARD&cAPE EDGE. HEAT BRAND ·ev· ONTO LID. PURPLE IN COLOR. @ PYC BALL VALVE, SEE LEGEND FOR SPECIFICATION @ FINISI-IED GRADE IN SHRUB AREAS ® PRESSURE SUPPLY LINE DEPTH AS PERSFEC.S. @ BRIC.K SUPPORTS G) DUAL UNION C.ONNEC.TIONS AS FART OF BALL VALVE @ LANDSCAPE FABRIC @ B/4" ROCK, I CUBIC FT. 0 6ALL VALVE (VALVE ISOLATION) G NO 5CALE E 1-1 CD RAIN SENSOR (SURFACE MOUNT ON OUTSIDE OF ENCLOSURE .t FER MANUFACTURER'S INSTALLATION INSTRUCTION&) ELECTRICAL CONDUIT TO RAIN 5EN50R SECURED TO WALL A5 REQUIRED WIRES TO IRRIGATION CONTROLLER TOTALLY ENCLOSED IN ELECT. CONDUIT TRA51-1 ENCLOSURE WALL (EXTERIOR) NOTE, ALL WIRE SI-IALL BE FULLY ENCLOSED IN ELECTRICAL JUNCTION BOX AND CONDUIT&. COORDINATE EXACT LOCATION& WIT!-1 OWNER. EXTERIOR WALL MOUNT RAIN 5EN5OR NO SCALE C ) , ' Fa,-! ) ' , l ' ~-POINT OF CCNNECTION TO f,!E:CYCLED I-IATER METE11t' eACKFL.ow DEVICE MASTER '' CONTROL Cl s LI l'<I TY OF CAFil..5eAD POTA6LE I-IATER MAINLINE. REFEI-! TO TD. DETAILS 1'<4 <51-lEET Lll.1/ DETAIL 'D'J AND W2rD (&I-IEET I.!:>/ DETAIL 'H"J FOi-! [,,(Ofl<K. TI-IIN RIGil-lT-OF-l'<AY. VALVE ' 'Y.t~, ~ .,,. ...l 11- FLCW METER ------11'<'.RIIJA T ION CONTROLLEI-! WIRE/ ~ ...l 11- 6ALL VALVE CONDUIT I I I I I I I I I I I I I I I I I I I I I I I I I I I tt,tttttt EXTEND CONTROL !'<IRE TO REMOTE CONTROL VALVE& AS REQUIRED <..'J---------IRRIG!ATION POINT OF TO IRRIGATION REMOTE CONTROL VALVE& eot-NECTION TO EXISTING! MAINLINE AS SI-IOI+! ON UTILITY PL.ANS <SEE 51-!EET Ll-6) IRRIGATION F.O_c_ AND A55EMBL Y Dl<\GRAM NO SCALE @ PI/C 50-I 81Z1 TI-ft:ADED IJ-IICN @ F'\.R"I...E VALVE eox AND LID (,,IITH eRANCH CIF<CUIT NUMeER STAMFED IN LID (SE!: SF!:C5). 3 ,,_, "'I \, : ~ -, i C)FINl&H GAAPE r,;-,~ PLASTIC VALVE eox i,,,i1TH 'V LOCKING COVER eY ~ lllZl!Z' OR EQUAL. MAl'IK LIP 'GATE VALVE' IN&T ALL FLlJ&I.I TO GIIIADE. @LINE &IZE l5RA&& GATE VALVE i,,,i1l1-l NON-Rl&INGo &TEH OR CITY APPROVED EQUAL. @VALVE eox EXTEN&ION, LENGTH A& REQ'P . 8' PIA. PVC CL&. 21Zi!Z' &LEE:VE -KEEi"' &LEE:VE FROM 13EARINGo ON VALVE OR l"'ll"'E. @<2) PVC &cl-I. 81D MAj_E ADAPTERS @PVC MAINLINE (3' OR &MALLERJ, ALL VALVE& 4' AND LAICGE~ &HALL eE IN&T ALLEP I-IITH Ol"'Ell!ATING NUT ONLY. G)3t4' PIA. 1"'1:A GAAVEL, I CU. FT. MIN. GATE VALVE (MAINLINE ISOLATION) NO SCALE CONTROLLER TESttrNAI STRIP C M I 2 3 4 & 6 1 FIGURE I 000000000 'D' (ORANG,E) 'C' (Gl'EENJ '6" <6LUE) A (RED> I-IOT (6LACKJ COMMON <WHITE) QUICK LINK ~SMITTErr;: LOCATE INSIDE CONTROLLER> 51e:.NAL WIR!: (OUTF\JTJ BROWN "v' "v' Y. Y. FIGURE 2 'D' (ORANc:,E) .----------------, "C" (Gdl<EEN) ~------------• e • <eLUEJ ..--------, I-IOT (6LACKJ-•RE_C_E,.IVE_[r;:_""II G) G) e G) SEE 5PEC5. FOR DEPTI-I @ PI/C Ff,£551.JF<E PIPE @ PVC 5CI-I 8IZI TI-IRl:ADED RISER OR NIPPLE <LENGTI-I Ai, fii!l:QUIRED> @ PI/C 5CI-I 81Z1 FEMALE ADAPTER <TYP> (5XTJ @ I' IN MULCI-I ~ @ PVC SCI-I 81Z1 ELL (55) , -:r;;.-~ , --. .-@ UNDl5TLIRBED/001PACTED 5Ue6RADE @ BRICK OR ~fii!l:TE Ot.lF I ORT& 14 13 (END TO END UNDER eox PERIMETER) CD MASTER CONTROL VALVE W/ FACTO~ INSTALLED PURPLE "RECYCLED l,,IATER" HANDLE @ I OJ. FT MIN. FfA GRAVEL @ SOLENOID @ R.IRFLE ~CLAIMED (,,!ATER I.D. TA6 (iJ l,IATE~ (,,II!,£ c:or+.IECTORS NOTE, USE ON.LY TEFLON TAPE ON ALL THREADED CONNECTIONS @ CCNTROL (,,llfii!I: (,,IJ 4' MIN EXTRA (,,!IRE COILED, , TAPED AT IIZI FT INTE~AL5 0HASTER VALVE NO SCALE TRANSMITTEB INSTALLATION <FIGURE I), 1. CONNECT Tl-IE SLACK Wlrr;:E TO CONTROLLEl'o?f> MASTEi-! VALVE/PUMP TE~INAL <ALONG WITI-I AN'T' OTHEl'it MASTErr.: VALVE WIRES> 2. eot-NECT Tl-IE WHITE [,,(lrr;:E TO TIMEl'o?f> cot"NON TErr.:MINAL ( ALONG, WITH ANY OTHER COHHON WIRESJ. 3. CONNECT Tl-IE err.:owN WIRE TO A GOOD STATION !'<IRE (THIS SI-IOULD SE A G:OOD WIRE THAT FitUNS OUT TO Tl-IE R!:CEIVER'S LOCATION). 4. CONNECT INPUT Wll-!ES TO OPEN STATIONS ON CONTROLLER <RED 'A', SLUE '6', C:!REEN 'C', AND 0~ 'D". TI-IESE DO NOT I-IAVE TO eE IN ~ER. LEAVE UNUSED Wlrr.:ES DISCONNECTED). NOT!;, FOR ADDITIONAL l~ATION CONTACT REED'S lfi!RIG:ATION, 112)-2& EAST KATELLA AVENUE, UNIT F, ANAHEIM, CA ':1280&, l-~-1':13-0312. fsECE;lyER INSTALLATION (1=1(•URE 2J, I. CONNECT THE 6LACK WIRE TO THE GOOD !'<IRE COMING ~ Tl-IE TRANSMITTER (Tl-IE SAME Wl!'E CONENCTED TO Tl-IE eROWN T~SMITTEFit WIRE AT Tl-IE TRANSMITTER). 2. CONNECT Tl-IE WHITE WIRE TO Tl-IE VALVE COMMON COMINc:s I kCH 11-E TIMER ( ALONGI WITH ALL OTHER COMMON WIRES). 3. CONNECT Tl-IE OUTRJT Wlrr.:ES TO THE VALVES (1-!ED 'A', SLUE ·e", GREEN ·c·, AND OfitANG:E 'D'. LEAVE UNUSED WIRES DISCONNECTED). "AS BUILT" TllLE REVIEWED BY: DAlE Cl) ....J -~ w 0 z 0 ~ C) -a:: a:: Ll-4 COMMON (WI-IITEJ <LOCATED IN VALVE eox WITI-I 'GOOD' CONTROL WIRE APPROVED FOR PLANTING 1---INS_PE_cT_o_R _______ o_A_TE_----1 AND IRRIGATION ONLY, INCLUDING PRECISE cOMMON <WHITE:> ~~~~~~~·::;~;;~~;.;-~s LOCATION OF PLANTING CARLSBAD MUNICIPAL WATER DISTRICT SHEET CITY OF CARLSBAD g 6 PLANNING DEPARTMENT SHEETS QUICK LINK BY REED 15 IRRIGATION ~~f~t~~~lfrJ"RuN~f AREAS. :~1-(tRTEs~~~t~TEJo~~CLAIMED ;::=====================::._-,--_ _:B:58:.48:,:,:1.:08;:88:,/'...'.R:LA:;;20~10:L,,.,..,,,.,~~~:::..-_J_ ______________ ~ NO 5CALE ViaSa t Building 6 CARLSBAD MUN ICIPAI. WATER DISTRICT ~r---..:cDlc=:,STR"=l':=:CT'::::A':"P,:.,:PR:,:,:O:..:.;VE:=D....:C::..:H'"'-AN.:.:cG=:ESrc-=::==:-i~=-I NO. DESCRIPTIDN APPROVED DATE DEVELOPERS NAME:_________ CAR~~L=:EAI. 92009 , ____________ 1---t-----------f------j----lADDRESS: ____________ t-=----=--r-------------1 DA\/1D A. HAUSER DATE DEPUTY CITY ENGINEER R.C.E.33061 EXP.6/30/08 SAN DIEGO COUNTY HEALTH DEPARTMENT APPROVED BY: DATE TELEPHONE: DATE PLAN PREPARED: _______ _ t--+------------+----+-----1 BY: D"""" BY, PROJECT NO. DRAWING NO. ~c~=.0~.-~----poo7-09 455-4L ...c Vl u, I .£ r ,;- $:, ...D 2 >---~ 1 ]--~ 0 SECTION NOTE&, 1. NO OTHER TRADE& (ELECTRICAL, Llc;,+,jTING) &!-!ALL USE THE &AMI: TIENCI-I A& IRRIGATION FIPE. 2. PROVIDE :24' OF COYl:R FOR DIRECT el.JRIAL CAeL.1:. ~-FROYIDI: l"'YC &cf-I. 4IZ> &Ll:1:YE& FO,r;t ALL WIRING AND F'IF'ING UNDl:R PAYING. 4. NO VERTICAL &TACKING OF IRRICisATION PIPE& IN THE &AME TRl:NCI-I. 05LEEVING NO 5CALE 2 CD FINISH GRADE @ 6ACKFILL @ Ff<£55l.1Fi1E MAINLINE PIPE @ DEETI-I Qf SLEEVES UNDEfs ROADS 6' OR SMALLER -3E>' COYER CisFi1EATER TI-IAN 6" -48" COYER t5CI-IEDULE &0 PVC DEETI-I QF SLEEVES UNDER PAVING <NON-ROADS) 3' OR SMALLER -18" COYER 3' TI-IROUGI-! Sv2' -24" COYER 6" OR LAF<GsE!li1: -36" COYER t5CI-IEDULE 40 PVC @ 6' MIN. @ DEPTH Of SLEEVES UNDER ROADS 6' OR SMALLER -36" COYER CisREATER TI-IAN 6" -48' COYER t5CI-IEDULE &0 PVC DEPTH Qf SLEEVES UNPEB PAVING <NON-ROADS) 3" OR SMALLER -18" COYER 3" TI-IROUGI-I Sv2' -24" COYEFe 6" OR LAF<GsEFe -36" COYER *SCI-IEDULE 40 PVC G) NON-PFi1ESSUFi1E LATERAL PIPE @ CONTFeOL WIFeE BUNDLE @ 2' MIN. CLEAN 6ACKFILL CD @ ® @ ® ® G) ® ® @) ® @ ® @ l~IGATION HAINLINE: SCI-I. e1Z1 FVC Tl:!:, 6x5xT MAINLINE X MANlfOLD 5IZE eALL TYFE I50LATION VALVE 5CI-I sq; PVC LNION MINIMUM 12" SEPARATION 6ETWEEN ALL YAL YE eoxee Fc!:HOTE CONT~L VAL YE SCH e1Z1 PVC LNION IRRIGATION 6U6-HAINLINE LATERAL LINE TO 5~INKLE~ l-iAl'cD5CAFE EDGE INEIT ALL MAINLINE 18' OFF OF HA!'i!DSCAFI: EDGE BALL T'T'FE I50LATION VALVE SCI-I elZI PVC UNION QUICK COUPl-E!o! SWING JOINT QUICK COUPJ..ER VALVE IN A FURFLE COl-OFc!:D, l'o£C'T'CJ..ED 1.-1.ATE~ ROUND VALVE eox NOTE, QUICK COUPLER MANlfOLD TO 6E SEPARATL I l'-!Ol"I RCY MANlFOl-D 0 NOTE: USE ONLY TEFLON TAPE ON VAL VE MANIFOLD LA y OUT ALL THREADED CONNECTIONS NO 5CALE j CD I-IAL.tc:&, curce. FAYING ji; OT~R CONC"9!!TE I~ !ENT&. @ 4' CU:ARANCI: TO f-lARD&cAPE @ INSTALL ~• Aeov£ GoRADE IN NEWI.. 'T' PLANTED AN:A&. RESET TO GRADE IN SODDED AREA&. @ FINl&l-i GoRADE @ FOP-LIi" ~TOR &F'RIM<I..ER ~ FACTORY INSTALLED NON-FOTA&E COYER @ F'VC &cf-I. 81D F'IEFAeRICATED 3'>1.!> DE..., .EE SWING JOINT A5SEMeL. 'T' Ol'il: FAeRICATE SWING JOINT WITl-1, (2) STREET ELL&, (1) Tl-lfl.EADl:D ELL, (1) &.I.&. X 12' NIPPLE, AND (I) &.1.5. X 4' NIF'FLI: G) ~ ~ TEE OR ELL @ F'VC LATERAL LINE ® @) 12· @ 3" -45 DEGREE& NOTE&, 1. FLU61-1 ALL FIPELINE& PRIOR TO INSTALLING &F'RINt<LE!li!e ON &WING JOINT 2. INSTALL ALL TI-IRl:ADED FITTING& WITI-I TEFLON TAPE, 1-1/2 TO :2 I-IRAF'&. ~-INSTALL I-IEAD& -UF' MAl'-l<ING FLAG ON EACI-I ROTOR LID. -4. CCHPACT BACKFILL AROLND ROTOR AND SWING, JOINT TO ~ OF ORIGINAL DRY Dl:N&IT'T'. S. I IEFABRICATED SWING JOINT TO BE &AME &IZE A& INLl:T TO ROTOR. 6. USE TEFLON TAF'E ON Tl-l!I.EADl:D COtNeCTION&. 0 FOF-UF ROTOR ~ NO SCALE NOTE&, '' ' &ECTION I. TWO OR MORE LATERAL& (OR MAIN LINE&) IN Tl-IE &AME TRENC!-1 SI-IALL BE FLACED SIDE-e'T'-5IDE I-IITl-1 A -4' MINIMI.M C' re: IION (BACKFILL) BETWEEN T~ PIPE& FOR BOTI-I I-IORIZONT AL AND VERTICAL CLEARANCE. ,. &LEl:YE ALL LATERAL&. ELECTRICAL, AND MAINLINE LINDER CONCRETE AND AFI--IAL T elJf<FACES. 3. ALL MEA&uil!EI IENT~ I ACM rOF OF PIPE TO FIN,51-i GRADE. CD BACl<FILL @ FINl&l-i CioRADE @ 2' MIN. CLEAN BAQQ=ILL @ ENT CONDUIT OR EC::UAL FOR 110 YAC I-IIRES HITI-I CAUTION TAP!: ® G) ® ® @ MAWED 'CAUTION ELl:CTRICAL' AND PLACED Dll'oECTL Y ABOVE CONDUIT. 24Y lf'i:RIGATION CONTROLLER HIRE: el.JNDLE T APl:D EYE!lrr 10' o.c. 10-1& FT. COIL I-IRAP AT EV£R'T' TURN AND YALYE HAINLINE ~ING TAPE. ~ CONTINUOU&L 'T' ALONG lltOUTE OF HAINLINE. LOCATE ONE TAI"£ IMMEDIATEL TON TOF OF Tl-IE MAINLINE l°IPE AND ON!: 12' AeoYE THE TOI"' OF MAINLINE:. -4' MIN. FURPLE, RECTCLED I-IA TER F'R£8:!!URE 11AINLINE PIP!: F'URPLE, RECTCLED I-IA TE~ NON-Fl'il:&&URE LATERAL PIP!: ~• OR SMALLER -le" COYER 3' TI-lROJeiol-l &~• -24' COYER 6' OR LA!'<GER -3'>' COYER 0 TRENC~ING B------No SCALE CD @ ® 0 / .. . EXPAN5I0N COILS, 30 INCi-i LINEAR LENCisTI-I OF WIFi1E, COILED ID TAG WATE!li1: PROOF CONNECTION Fi1EMOTE CONTFeOL VALVE WI FACTORY INSTALLED, RJRPLE, "RECYCLED WATEFe" 1-lANDl-E ® ® G) ® ® @ ® @ ® @ (@ @ @ RJRPl-E COLO!li1:ED, Fi1ECYCLED WATER, VAL YE 60X WI l-OCKINu 60L T -DOWN LID FINISH GRADE/TOP OF MUl-CH PVC SCH e,q; UNION PVC LATERAL PIPE PVC SCI-I 40 ELL5 (TO ANCisLE PIPE TO 5FECIFIED DEPTI-I) 4' MIN. -6" MAX. PVC MAINLINE PIPE PVC SCI-I 40 ELL 6RICK SUPPOFeTS I CU. FT. PEA C:sRAYEL -4' MIN. PVC SCI-I &0 NIPPLE PVC MAINLINE NOTE, USE ONLY TEFLON TAPE ON ALL THREADED CONNECTIONS 0 REMOTE CONTROL VALVE E------No SCALE J 00 NOT IN5TAcl IN AREA SUBJECT TO f: OODl~G ' 0 i--i.J6" MAX ' ' -----···-r :ic.=cc.c::, ---- l~~M -R 11 Jr l llEM I I I • , ~ I ~-:::l::t=:::::;:~./ -,,, l.J ----- 11 II I J ESCRIPTION tER A.ND VALVE BY DISTRICT E K HARO OR TYPE L HARD C PPER COi'!' . QR BRA$~ .. ~o-ELBOW L= BRASS NIP -• I + ·-· 7 . :-i • ;. . l.3 SP C Wl,_ CARLSBAD MUNICIPAL WATER 01 TRICT .bL c[.7-. .... ••• 2 INCH ANO UNDER BACKFLOW INSTALLATION REDUCED PRESSURE 0 BACKFLOW PREVENTER ~ NO SCALE CIN £NGINElR OAT[ ""'°""• .... "· W20 CARLSBAD MUNICIPAL WATER DISTRICT ---DAI/ID A. HAUSER DATE DEPUTY CITY ENGINEER R.C.E.33081 EXP.6/30/08 SAN DIEGO COUNTY HEALTH DEPARTMENT APPROVED BY: DATE I. 2. 3. -4. -/ 0 - . £! NOTE, I4'x~• RECT ANC:tULAR, PURPLE, FeEC'T'CLED WATEFe VALVE 60X T'T'P.l PUFePLE, Fi1EC'T'CLED WATEFe, QUICK COUPLING V Al-YE eox. Tn='. 0 0 0 '\ 0 0 0 4 4 4 0.: >-I- £! - CENTER VALVE eox OYEIQ: FcEMOTE CONT~L VALVE TO FACIJ..ITATE SERVICING, VAJ..VE. SET RCY AND VALVE eox Ae5EM6L'T' IN ~D-COVEIQ:/SHRUB A""=A WHERE POSSIBLE. SET eoxes PAAALLEL TO EACI-I on-IE~ AND FEl-if"ENDICULAIQ: TO EDGE. AVOID I-IEAVIL'T' CCMPACTING SOIL AROUND VALVE BOXES TO ~VENT COLLAF'SE AND DEFO!liMATION OF YALYE BOXES. 0 VALVE BOX J._AYOUT c------NO SCALE ,.(j') 6' MIN. J_~ 2" MAX. 1' MIN. CD cONclli'f:TE cu~. WALK.e, OR OTHER IMFROVEHENTS. @MAINLINE/ 5Ue-MAIN FITTING -PVC SCI-I e,lt) 5 X 5 X 1" MPT OR S X I' MPT ELL NOTE5, @F,Nlel-1 GIUDE @~• ROIJ,,ID, FU~E COJ..OFc!:D, fli!EC'T'CLED WATER VALYE eox WITH LOCKING LID INSTALL FLU6H TO GAADE, MAll!K LID 'QC' @1' IN GROUNDCOVEFi!: I SI-IRUe Al'o£A @MAINLINE DEPTI-I VARIES G)BRONZE 2 PIECE QUICK-COUPLING VALYE-I" INLET I-IITI-I LOCKING. NON-POT ABLE, RUeeER COYER @TI-IO S/&' XI&' YERTICAL RE-BAR I-IITI-I TWO STAINLESS STEEl-CLAMFS @PVC SCI-I e,lt) NIPPLE I" X 3" LONG, @s• DIA. PIFE SLEEVE-KEEP SLEEVE FROM 6EARINGo ON RISER OR PIPE. @314' TO !' CRUSHED ROCK GRAYEl-- 12" DEEP @PVC 5CI-I. e1Z1 F'!l<EFA6RICATED 31&0 DEGREE SWING JOINT A55EM6L 'T' OR FAelQ:ICATE SWING JOINT WITl-i, (2) STREET ELLS, (IJ T~ADED ELL, (IJ 5.1.&. X 12' NIPPJ..E, AND (I) 5.1.5. X -4" NIPPLE I. WRAF' ALL TI-IFcEADS WITl-1 TEFLON TAFE 1-112 TO 2 WRAFS MAXIMUM. 2. CCMPACT 60IJ..5 A~D VALYE eox TO elZI"-OF ORIGINAL DRY DENSITY. 3. INSTAJ..L HEADS -UP MA'"11<.ING, FL.AC. ON VALVE eox LID. CONTRACTOR TO MAINTAIN MAl-!KING UNTIL PROJECT IS COMF'l-ETE. -4. FURNlel-1 FITTINGS AND PIPING NOMINALL 'T' SIZED IDENTICAl-TO NCMINAL QUICK COUPLING. VALVE INLET 5IZE. S. QUICK. COUPLER VALVES SI-IALL !SE OF A TYPE AFF~VED FOR l'o£C'T'CLED WATER USE. 0GlUICK COUPLING VALVE NO SCALE "AS BUil T" TillE REVIEWED BY: DATE CJ) ...J -~ w 0 z 0 -~ CJ -0:: 0:: - Ll-5 APPROVED FOR p LANTING i----,, 1...,..,NS=PE.,,,,CT,,..,OR..,,.....,==::-:-::--=c=:--::-cDA=TE=c::=-i AND IRRIGATION ONLY, CARLSBAD MUNICIPAL WATER DISTRICT SHEET CITY OF CARLSBAD INCLUDING PRECISE 7 PLANrilNG DEPARTMENT 9 SHEETS .& •AL.IPO ■■U, ····••ATIO ■ MW PELTZ+ ASSOCIATES LANDSCAPE ARCHITECTURE SOLANA BEACH, CALIFORNIA 858.481.0888 / RLA 2010 LOCATION OF PLANTING AREAS. DISTRICT APPRO"lll CHANGES NO. DESCRIPTION APPROVED DATE DEVELOPERS NAME: __________ _ 1-+------------+----+----1ADDRESS: DA TE PLAN PREPARED: +---+------------+----+----! BY: TELEPHONE: PRIVATE (ONSITE) RECLAIMED WATER SYSTEM FOR: ViaSa t Building 6 ORllN BY: CHCICD BY: 6J05 EL Cl,MINO REAL CNILSIW>, CAUF-ORNIA 92009 • PROJECT NO. PD07-09 DRAWING NO. 455-4L ..c <11 <II I ,&. r ..... " ,J) ™"'-l&T AT l'ITTING& IN f'OI.ND8 AT -pol l"I~ er-· <Ill" 22-1.2· DEAD ENP& INCMI!!& ~ l!IENP& e&IP& 4 TEE& I-Ir.I" 2 2-11:1 3 3-ln .ol II 6 9 Ill) 12 <!Ill 64 93& l,3!111 ~1- 2.2¥ 3---'4,!11111> 9~ 12,N)C) 18,- 2211 3H 1111111 1116 962 1,2-4& 1,'!IIIIIIIZ' 2,111111 .ol~ 6 ,'!IIIIIIIZ' 9,11N II& Jee, 26f' 39& <1'311 6311 !!11& 1,3&& 2.29" 3,5.o!C) !l(IJIDID 2'311 -4&& 66/D u& 1.26£1 1,62,t) 2,49" 3,5!141 &..,,, !!l,a;c> 12,N)C) ™fl!U&T AT FITTING& IN 6 AT 69!1 kPa OF 1-!ATEl't 9£1" <19• 22-1.2" DEAD !ND& (..,) l!IEND& l!!IEND& eEND& 4 TEE& 39.1 ,-.e _,.3 1111.e 1312 .a !141.9 291f:>.3 1!1111.11 NI 2"2.ol.9 63.11 .oll6f:>.& 2269.& 11&1 3931 16.2 62"1.9 l13&'!1.9 1113.3 43113.3 96.!!I 1921 -42alll.!!I 22"2.9 &6f:>1 1"1.6 1"212.9 !1&41).3 20.9 12"9 121 1&&1& 1MN <1339.& 11"N!>.!o 1&2.<1 22"21.& 12111'&11.& 6163.3 M1!1.& :W3.2 )169& 2""25 ,,,,._.!, 26"11 2&.ol !e,96C) 3"1£)& 1&1&3 -411.212.!I 3".ol.9 ef:>&'4& ,!)16111) 222!1f:> &696£) EXANl"LE, l'cr a pr••"• ro N pol /1'»3.!o kPa) or, a .ol rn. /1"1.6 mJ we, Tabi. Jelf:>&.l.<l<'aJ Indlcat.o I,62,t:, ~ /12"9 NJ ror -,:,.I ( 6" lcl"'a J. n--.rore, tot., I ltruo\ ror N por (~.& l<l"a) 111111 _, I-In ll-1,62,t:, i:>OU'ICII (12"9 N) ror • toYI tm.-\ or 2,43" r,:-<1"1111111 N). To cleta,nl-the bearing area ro tln»l bloc:b, r.r« t.o Tabla Jelf:>&.1.<l<'b) ror the .. ,. -Ing load or Iha ,orl afld Cllrvrde the \Olal tln»l b!j the .. ,. bearing load. 0 Tf-lRUST BLOCKS NO SCALE 0-G)-- z r: io z -r: PLAN VIB-4 eot-N:CTOFI: Fo,;;t 11/DVAC WI~ ( AI..L 5FLICE5 TO eE AFFl'i!OVED B'T' CIT'T' ~IOFI: TO INSTALLATION) INf>!AI LATIQN &TEl'5, 1. ~STRIP INSULATION &/5' I IWM ENDS 2, TWIST WIiii£ NUT '-"lTIL ENDS OF 1-11111£ lliEACI-I eoTTOH. 3. 3M 9COTCI-I-LOK -4. "3516 5EALINCs BAG MIX CONTENTS OF 5EALll'-k:s eACro l"E~ MANlFACTI.RR CUT JS" CfF END Cf= BAG AND IN5E~ 1-11111£ NUT TO OFl"'051TE END. ~-COHl"'LETED 1ar$ 5EALI~ BAG. ~p OPEN END OF-&EALING eACs I-IITI-I T AF!:. LEAVE TAPED END IN RAISED P051TION UNTIL l'cE51N SETS. fp\ ~IRE CONNECTION _. ELEC. FULL BOX VNOSCALE PLANTING. LAXQUI lfsf\'1GAI1QN LAXQUT " EQ. r, 'X' ~12('X") (TYP) (TYP) ENP CONDITION 21---~ •, • ,~'ffi! trjillr?Jn . , ; Jtf io/©:c!I"" ' . ' ~;' 0 PLANTER FOT IRRIGATION NO SCALE (D ~ leeLEJC! ON Fitl&EJC! 3' AeOVE MULCI-I <&EE !"'LAN& FO!lt IU19EJlt OF- eueeLEl'i.5 l"E~ POT) @ FINlet-1 GAADE AT 2' LA'T'EJlt OF-MULCI-I @ PLANTE~ !"'OT AND SAUCEJlt, &EE A~I-IITECTURAL DJCIAWING,& -&ET LEVEL ON FINl51-!ED GRADE @ ~5ED !"'LANT MATERIAL 5EE PLANT!~ PLAN FOl't T'Y I E @ PLANT JltOOTBALL (51-!0WN FOl't kEri:!'1£NCEJ @ 3/-4' IJltRIGATION LATE~ LINE <T'T'PJ G) PVC &cl-I -4IZ> TEE ( M f.':EQ'D) @ IJltRIC:sATION MAINLINE (51ZE PER PLAN> @ CONCRETE PAVING @ l"'LANTE!li: BACKJ=ILL ® 5ET TOP OF-MULCI-I 2" BELOW FitlM OF !"'LANTER POT @ SCI-I 8/Z'J TI-IREADED ~ISE~ (A5 fliEQ'D) @ MAKE DAAIN I-IOLE AND lli:ISEl'i! PENETRATION WATE~ TIGI-IT WITI-I SILICON ---------"i , ® 0 8 1--------- CD WALKS, CU~, PAVING, l,,,IALLS OR OTI-IER CONCRETE IMPROVEMENTS. ® 4' MIN. -112'' MAX, FROM CURBS, WALKS, 6" FROM WALLS ® 2" 0 FINISI-I GsRADE IN PLANTER ® POF-UF SPRAY I-IEAD WITI-I NON-FOT A6LE COVER ® FVC SCH. 80 TI-IREADED NIFFI...E <LENGTI-I AS REQUIRED) G) (2) PVC SCl-l.4,Z, STREET ELL'S ® PVC LATERAL LINE ® FVC SCI-I. 80 TI-IREADED NIPPLE <LENGTI-I AS REQUIRED) @ PVC SCH.4':, STREET ELL'S ® 2" IN MULCH AREAS, FLi.161-1 IN TUFif' AREAS NOTE: USE TEFLON TAPE ON ALL TI-IREADED CONNECTICINS .,.....----1 2 _,,---{3 ----14 CD W'!""':..:.,_.__---{6 ~=+-...... -----<1 ! i - 0 CD @ 3' FOR eueeLER, 12' FOR SPRAY eue5LER OR SPRAY "4EAD WI NON-POT A6LE 51-!RUe ADAPTER @ UV RADIATION RESISTANT 1/2 INC-14 PVC SCI-I 80 NIPPLE (LENGTI-I AS REQUIRED) ANTI-DRAIN SPRING CHECK VALVE <SEE IRR. NOTE) FINISI-I G:RADE/TOF OF MULC-14 FVC COUPLING FLEX RISER FVC SCI-I 40 TEE OR ELL 0 FOF-UF SPRAY f-lEAD NO SCALE 0 SPRAY f-lEAD ON RISER NO SCALE CD l,,,IATE~ 1-,llf'E CONNECTOR<SJ ® 2' MIN. 5PAl'E Wll"E, COILED AND IDENTIFIED A5 'CONTROLLER I® SPARE 1-,llf'ES' ® ® PVC SCI-I 4':, CAF 0 2' MIN. ® tr;:,• DIA. ROUND PLASTIC VALVE eox ® PVC FRE5SURE FIFE G) BRICK OR CONC. 5UPPORTS (MIN. OF FOUR FER eox) ® I CU. FT MIN. PEA GRAVEL 51.MF ® UNDISTUpeED/COMFACTED 5UeGRADE 8 @ I" A60vE flNISI-I GsRADE ® SEE TRENCI-I PET AIL 6/L 1-5 !=OR DEPTI-I 0 FIFE AND WIRE STUB OUT NO 5CALE 2 4 CD STAINLESS STEEL ENCL05URE .-. ~ 6ACKFLOl,,,l PREVENTER ANCI-IOR ROD (T'T'F.) @ FOUJlilED CONCl'ETE BASE MED. eROOM FINISl-l llii>' MIN. .-TI-IICl<NE56-EXTEND 6' 6 eEYOND OUTSIDE DIHENSION5 OF ENCLC>el.lRE. l"LAN YIEH @ I-IA TER SERVICE INLET Pf PING @ I-IATER 5E~ICE OUTL.ET PIPING G) FINISI-I GRADE ® 2' FROM FINl51-1 GsRADE IN SI-IRU6 Al'EA 2 . . 5 2 l CD CI-IECK VALVE G) @ @ PVC 5C+-l 4ei 5xT MALE ADPT. PVC LATEAAL PIPE (T'T'P.) FLUSI-I 1-1/ flNle.1-1 GR.ADE IN TUFif', 2' IN ~DCOVER @ 1(2;)' DIA, FltOlND VAL VE eox WITI-I LOCKING LID @ BRICK OR CONC!liETE eu~Te ON COMPACTED SUBGRADE ITHfii?EE PER eox MIN.) G) 3' MIN. @ COMPACTED SUBGRADE @ 12' MIN. 0 IN-LINE CI-IECK VALVE F ~N~o=-=ex:=-=-A~L~E=------------------------- "AS BUILT" lllLE REVIEWED BY: DATE Cl) _J -~ UJ Cl z 0 -~ C) -a:'.'. a::: - Ll-6 APPROVED FOR PLANTJNG1--::1~NS=PE=~=~------==----□A_rr_----l AND IRRIGATION ONLY, CARLSBAD MUNICIPAL WATER DISTRICT ELEVATION INCLUDING PRECISE SHEET CITY OF CARLSBAD 0 BACK.FLOW ENCLOSURE ~~~~~;;·::;;~~~:; LOCATION OF PLANTING 8 9 PLANNING DEPARTMENT SHEElS I 1-----------------------------LANDSCAPEARCHITECTURE AREAS. PRIVAlE (ONSllE) RECLAIMED NO SCALE NO SCALE SOLANA BEACH, CALIFORNIA WAlER SYSTEM FOR 858.41!1.0888 / RLA 2010 : ,-------------.--_:::::::.~01;s1R;,;1c;r~A;,PP~R;oVE~□~c:;-;H7,AN:-;::c~Es~~~=---+----------------J ViaSa t Building 6 CARLSBAD MUNICIPAL WATER DISTRICT i-:-:-:::,-----"-'~:c=:::":::-:-:-c-;.::::.....:.;.;;c.:;.;.:::::.::;-,-==,...,....,=-r------l NO. DESCRIPTION APPROVED DAIT DEVELOPERS NAt.lE: ___________ 6305 EL c.lMINO REM. 1-:----------___ f--+------------+-----1----lADDRESS: DAVID A. HAUSER DA IT DEPUTY arr ENGINEER R.C.E.33081 EXP.6/30/08 SAN DIEGO COUNTY HEALTH DEPARTt.lENT ITLEPHONE: APPROVED BY: DAIT DAIT PLAN PREPARED: _______ _ l--+------------+-----1----lBY: CARLS!Wl, CALIFOANL'\ 92009 5-9~ DAIT ORWN BY, PROJECT NO. DRA'MNG NO, ~~-~-0 •-~----~PD07-09 455-4L J:. \11 Ul ' .£. r 00 ~ ,,S) SIDEWALK-----------... ~--METER eox WITI-I METER CURe----- A~X. 8' POTA6LE SERVICE LINE---------12' MINIMUM ~ IIZ>' MINIMUM i-lATER l~IGATION MAINLINE WITI-I SLEEVE I --------- RECLAIMED WATER l~IGATION MAINLINE WITI-I SLEEVE--------~ 0 1--F_O_T_A_6_L_E_M_A_IN_L_IN_E_C_R_O_6_6_IN_G ______ _ NO SCALE D 7 8 SIOC'l,ALK WR8 & OJ!T[R METER ANO BAU VAL\!£ BY D·STRICT NOTES: 1 CONTRACTCIR SHALL ADJUST ANGLE I • • YIU.VE &: METER BOX TO f C. AFTER ~-5i· ~~--•~·=·::- SUJEWALK S INSTALLED &: itPPROVf.D 2. DISTRICT NLL SET METER AND BAU. V"l.V[ ~. • I • • • •· • • . .. CONNECT TO 0UTL£l ASSY . . . . . 3. "LL COPPER .JO~TS StiAI.L BE SI L\.t'R SOU>EREO IN COlfCIRMANCE WITH SPEClflCAT•ONS 4. TAP TO MAIi< TO 8( M!Nt\lUM OF 24" FROM NEAREST COUPUNC, FITTINC, V"l. VE, BEU. OR OTHER TAPS. OETA..,. t.ON-CONTIGJOUS SIDCWAIJ< fl aJRB ~-POSITON IINOOE 1,4,Q.,AY EETWEEN PIPELINE IINO WE ER BOX 6. JNT[RICIR or W[T[R BOX SHAU E£ a.EAR OF llFRRtS TO DlPTH OF ,r ANO CORP STOP ruLL y EXPOSED DESCRIPTION _SPEC ¥ COPP[R T'l'PE K" ' sorrj 1----';---+-~u'-a:c,LET ON Py::; =pR""E"="ssus=Rf.=--=P1P=E~----5- 0UTI.ET ON AC PIPE 6 -.;---i--OVTLET ON CML&C STE[ PIFE 9 ___ _,,,ou,'--'T,,,LE':cl--=ON-□;,;UC~T-';;IL,,,,E ==''l""ON~P~ll'L~---------------1--9 1• ANCLE METER SlOP MEIER BOX ANO jii-,co<i'i;;t'""Rr,!""f%'"".itt,.,.;~ A tA) [V APP~O\IEO IDATE /ii) 11lNICIP w DISTRIC t----+-----+----1 I" WATER SERVICE CONNECTION FOR 5/8", 314• a I" HETERS RECLAIMED WATER IRRIGATION WATER METER NO SCALE 6 NO SCALE STREET SURFACE----------~ POTA6LE--~ MINIMUM REQUIRED VERTICAL SEPARATION----------- RECLAIMED WATER IRRIGATION MAINLINE IN SLEEYE----------- NOTE: 3.S' 12' ALL RECLAIMED WATER IRRIGATION PIPE AND SLEEVES 51-!ALL 6E RJRPLE AND LA6ELED AS SPECIFIED IN Tl-IE "STANDARD SPECIFICATIONS FOR PRIVATE IRRIGATION SYSTEMS WATER DISTRICT' RULES AND REGULATIONS FOR CONSTRUCTION OF RECLAIMED WATER MAINS OCTO6ER 1~~3. POTABLE 6ERVICE LINE CRO661NG NO SCALE A OALIPORNIA OOll~OIUTION MW PELTZ+ ASSOCIATES LANOSCAPE ARCHITECTURE SOLANA BEACH, CALIFORNIA 858.481.0888 / RLA 2010 ~ 'lcl','& WAlER •"""I<!,~ 0 3 • • • .• • • • . . • • l 8"MIN. l 1 1 :i: :::> :i: ~ :i: i:o st • st N CD ATTACH SIGN TO POST USING 11~" X 2V2" ANODIZED LAG 60L TS (2 PER SIGN). DEFORM THREADS TO PREVENT UNAUTHORIZED REMOVAL 0 @ @ ® RECYCLED WATER "DO NOT DRINK" SIGN, SEE 51-!EET T-2 FOR DETAIL 4" x 4" PRESSURE TREATED WOOD POST SET IN CONCRTE. FINISHED GRADE SET POST IN I C.F. OF CONCRETE <TROWEL FINISH IF EXPOSED, SLOPE TOP OF FOOTING TO DRAIN. NOTES, I. I-IEIGI-IT A6OYE GRADE: 42" MAX. TO TOP OF SIGN. 2. VERIFY EXACT LOCATION AND MOUNTING I-IEIGI-IT WITI-I WATER DISTRICT REPRESENT I YE. 3. MOUNT TO ADJACENT FENCE OR WALL WITI-I APPROVED SYSTEM IF ADJACENT SURFACE 15 NOT AVAILA6LE OR ACCEPT A6LE. RECLAIMED WATER 11 DO NOT DRINK" 61GN 0 MOUNTING DETAIL C NO SCALE "AS BUILT" TITLE DATE REVIEWED BY: (f) _J -~ w 0 z 0 I- <( (9 -c:: c:: - Ll-7 APPROVED FOR PLANTING 1---1N_sP_Ec_To_R ___________ D_ATE __ --1 ND IRRIGATION ONLY, CARLSBAD MUNICIPAL WATER DISTRICT INCLUDING PRECISE SH~ET CIT!AN~! D~~R~~~TBAD LOCATION OF PLANTING AREAS. PRIVATE (ONSITE) RECLAIMED WATER SYSTEM FOR : 9 SHEETS DISTRICT APPROVED CHANGES CARLSBAD Mu NI Cl p AL WA TER DISTRICT 1-,N-:--::O'T_ ---=":D==E'='sc==Rc=IP,::Tl""ONC---'----'TA-:--::P::::P:::cRO::-:-VE::::D::,-::Dc-:-A-::::-1TE DEVELOPERS NAME: ---------- ViaSa t Building 6 DAVID A. HAUSER DATE DEPUTY CITY ENGINEER R.C.E.33081 EXP.6/30/08 SAN DIEGO COUNTY HEAL TH DEPARTMENT APPROVED BY: DATE 6305 EL CAMINO REAL · CARLSBAD, CALIFORNIA 92009 1--+------------+---f-----, ADDRESS: _____________ r--::-::-=:-:-=,-;--------,-----------1 APP~( 6r • ~ ... :fr TELEPHONE: ____ _ PLANNING DRWN BY: DATE PLAN PREPARED : _______ _ 1--+------------+---f-----, BY: CHO<D B'I': c;.q_c,~ DATE PROJECT NO. DRAW1NG NO. P007-09 455-4L