HomeMy WebLinkAboutDWG 451-6L; SDP 06-13; ASPIRATIONS DAY CARE CENTER; 01-07GENERAL RECYCLED WATER NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE 'v\HH THE CARLSBAD MUNICIPAL WATER DISTRICTS "CARLSBAD RECLAMATION RULES AND REGULATIONS FOR CONSTRUCTION OF RECLAIMED WATER MAINS" DATED OCTOBER. 1993. 2. DRINKING FOUNTAINS SHALL BE PROTECTED FROM SPRAY OF RECYCLED WATER. BEST MANAGEMENT PRACTICES SHALL BE USED TO MINIMIZE RECYCLED WATER ENCROACHMENT ON PUBLIC FACILITIES SUCH AS PICNIC TABLES, BBQ'S, PLAYGROUNDS, SAND, LOTS, ETC. 3. BEST MANAGEMENT PRACTICES SHALL BE USED TO ELIMINATE OR CONTROL TO THE BEST EXTENT POSSIBLE, PONDING, RUN-OFF, OVER-SPRAY AND MISTING. 4. HOSE BIBS ARE STRICTLY PROHIBITED. 5. ON-SITE CROSS-CONNECTIONS BETWEEN RECYCLED WATER LINES AND POTABLE WATER LINES IS STRICTLY PROHIBITED. 6. NO SUBSTITUTION OF PIPE MATERIALS 'MLL BE ALLOWED 'MTHOUT PRIOR APPROVAL OF THE CITY OF CARLSBAD MUNICIPAL WATER DISTRICT. 7. ALL ON-SITE PIPES SHALL HAVE WARNING TAPE PER CARLSBAD MUNICIPAL WATER DISTRICT'S RULES AND REGULATIONS. 8." THE IRRIGATION SYSTEMS SHALL RUN BETWEEN THE HOURS OF 10:00PM AND 6:00 AM . THE FOLLO\MNG MORNING (SPOT IRRIGATION COULD BE DONE AT A DIFFERENT TIME \MTH QUALIFIED SUPERVISION PERSONNEL ON SITE). 9. PROVIDE A MINIMUM OF AT LEAST 18-INCHES OF COVER OVER ALL 'MRING AND PIPING. 10. NON-DESIGNATED USE AREAS SHALL BE PROTECTED FROM CONTACT \MTH RECYCLED WATER, WHETHER BY 'MNDBLOWN SPRAY OR BY DIRECT APPLICATION THROUGH IRRIGATION OR OTHER USE. LACK OF PROTECTION, WHETHER BY DESIGN, CONSTRUCTION PRACTICE OR SYSTEM OPERATION, IS STRICTLY PROHIBITED. 11 . IRRIGATION HEADS SHALL BE RELOCATED OR ADJUSTED TO PREVENT OVER-SPRAYING ON SIDEWALKS, STREETS AND NON-DESIGNATED USE AREAS. 12. RECYCLED WATER QUICK COUPLING VALVES SHALL BE OF A TYPE DESIGNED FOR THE USE OF RECYCLED WATER DISTRIBUTION SYSTEMS (SPIKES NOT INTERCHANGEABLE \MTH QUICK COUPLER SPIKES) PER CARLSBAD MUNICIPAL WATER DISTRICTS RULES AND REGULATIONS. 13. METERS SHALL BE SIZED BY THE CITY OF CARLSBAD MUNICIPAL WATER DISTRICT. 14. ALL IRRIGATION PIPE SHALL BE STENCILED WITH THE WARNING, "NON-POTABLE OR RECYCLED WATER", COLOR-CODED (PURPLE) AND LAID WITH WARNING TAPE AND STENCILING ORIENTED TOWARD THE TOP OF THE TRENCH PER THE CITY OF CARLSBAD MUNICIPAL WATER DISTRICTS RULES AND REGULATIONS. 15. ALL POTABLE WATER AND RECYCLED WATER PIPING SHALL BE INSTALLED \MTH THE STENCILING ORIENTED TOWARD THE TOP OF THE TRENCH. 16. WHEN POTABLE WATER LINE AND RECYCLED WATER LINE CROSS, THE RECYCLED LINE SHALL BE INSTALLED 'MTHIN A PROTECTIVE SLEEVE. THE SLEEVE SHALL EXTEND 10-f'EET FROM EACH SIDE, FROM THE CENTER LINE OF THE POTABLE LINE, FOR A TOTAL OF 20-f'EET. 17. A 10-FOOT HORIZONTAL SEPARATION BETWEEN POTABLE WATER AND RECYCLED WATER MAINS MUST BE MAINTAINED AT ALL TIMES. THE POTABLE LINES MUST BE INSTALLED ABOVE THE RECYCLED LINE. 18. A MINIMUM OF 12-INCHES OF VERTICAL SEPARATION BETWEEN UTILITIES MUST BE MAINTAINED AT ALL TIMES. 19. • DEVELOPER/ CONTRACTOR SHALL CONDUCT A CROSS-CONNECTION TEST AND COVERAGE TEST AS DIRECTED BY THE CARLSBAD MUNICIPAL WATER DISTRICT ENGINEER OR THE SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEAL TH PRIOR TO ANY USE OF RECYCLED WATER. 20. QUICK COUPLING VALVES USED IN RECYCLED WATER SYSTEMS SHALL CONFORM TO THE FOLLO\MNG: A. RECYCLED WATER-QUICK COUPLING VALVES USED IN RECYCLED WATER SYSTEMS SHALL HAVE ACME TYPE THREADS AND PURPLE COLORED LOCKING COVERS PERMANENTLY ATTACHED TO THE VALVE. QUICK COUPLING VALVES SHALL BE NELSON NO.7645, HUNTER NO.HVIOOA-RL-NP OR APPROVED EQUAL. (SPIKES SHALL NOT BE INTERCHANGEABLE 'MTH POTABLE WATER QUICK COUPLER SPIKES) 21 . THE REQUIRED CROSS-CONNECTION INSPECTION SHALL BE DONE BY EITHER THE CARLSBAD MUNICIPAL WATER DISTRICT AND/OR THE SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEAL TH. COPIES OF INSPECTION REPORTS \MLL BE FORWARDED TO THE NON-INSPECTING PARTY. 22.• DEVELOPER SHALL SHOW THE LOCATION OF R.C. SIGNS "DO NOT DRINK" ON THESE PLANS. 23.• AN ON-SITE USER/SUPERVISOR SHALL BE DESIGNATED IN 'il'vRITING, THIS INDIVIDUAL SHALL BE FAMILIAR 'MTH PLUMBING SYSTEMS \MTHIN THE PROPERTY, \MTH THE BASIC CONCEPTS OF BACKFLOW/ CROSS CONNECTION PROTECTION, AND THE SPECIFIC REQUIREMENTS OF A RECYCLED WATER SYSTEM. COPIES OF THE DESIGNATION, 'MTH CONTACT PHONE NUMBERS SHALL BE PROVIDED TO THE SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH AND CARLSBAD MUNICIPAL WATER DISTRICT. IN CASE OF EMERGENCY CONTACT; MAINTENANCE SUPERVISOR OR AFTER HOURS CONTACT ALAN HEIM ALAN HEIM AT (760) 521-3919 AT (760) 521-3919 24. SHOW ALL PUBLIC AND PRIVATE POTABLE WATER MAINS ON IMPROVEMENT PLANS. •1TEMS 8, 19, AND 23 SHALL BE REQUIRED JUST PRIOR TO THE ACTUAL USE OF RECYCLED WATER. •1TEM 22 THE SIGNAGE SHALL BE A PART OF THIS I.P. BUT THE ACTUAL SIGNS AND TAGS WILL BE INSTALLED JUST PRIOR TO ACTUAL USE OF RECYCLED WATER. 25. ON RECYCLED WATER SYSTEMS, ALL APPURTENANCES (SPRINKLER HEADS, VALVE BOXES, ETC.) SHALL BE COLOR-CODED PURPLE PER AWWA GUIDELINES AND SECTION 116815 OF THE CALIFORNIA HEALTH AND SAFETY CODE. 26. THERE SHALL BE A PHYSICAL SEPARATION BETWEEN ADJACENT AREAS IRRIGATED \MTH RECYCLED WATER AND POTABLE WATER. SEPARATION SHALL BE PROVIDED BY CONCRETE STRIPS, CHAIN-LINK FENCES OR OTHER MEANS AS APPROVED BY THE WATER DISTRICT AND D.E.H. IRRIGATION BACKFLOW NOTE ALL IRRIGATION BACKFLOW PREVENTERS SHALL BE TESTED BY A CERTIFIED TESTER AND RESULTS MUST BE GIVEN TO THE THE CITY AND THE CARLSBAD MUNICIPAL WATER DISTRICT. PIPE BETWEEN THE METER AND BACKFLOW PREVENTER SHALL BE SCHEDULE K HARD COPPER. APPROVED CONTRACT BACKFOW TESTERS CAN BE FOUND ON THE CITY WEB SITE AT www.ci.cartsbad.ea .us/pdldoc.html?pid=340. SIGNAGE NOTES THE FOLLO\MNG GUIDELINES FOR THE USE OF RECYCLED WATER ARE TO BE PERMANENTLY POSTED INSIDE THE DOOR OF EACH CONTROLLER WHERE THEY ARE EASILY VISIBLE. PLACE ON 8-1/2"X 11" SIZED SIGN. COLOR: PURPLE BACKGROUND \MTH BLACK LETTERING. I GUIDELINES FOR RECYCLED WATER USE 1. IRRIGATION BETWEEN THE HOURS OF 10:00PM AND6:00AM ONLY. WATERING OUTSIDE THE TIME FRAME MUST BE DONE MANUALLY \MTH QUALIFIED SUPERVISORY PERSONNEL ON-SITE. NO SYSTEM SHALL AT ANY TIME BE LEFT UNATTENDED DIJRING USE OUTSIDE THE NORMAL SCHEDIJLE. 2. IRRIGATION IN MANNER THAT WILL MINIMIZE RUN-OFF, POOLING, AND PONDING. THE APPLICATION RATE SHALL NOT EXCEED THE INFILTIRATION RATE OF THE SOIL. TIMERS MUST BE ADJUSTED SO AS TO BE COMPATIBLE 'MTH THE LOVIIEST SOIL INFILTIRATION RATE PRESENT. THIS PROCEDURE MAY BE FACILITATED BY THE EFFICIENT SCHEDULING OF THE AUTOMATIC CONTROL CLOCKS, (I.E. EMPLOYING THE REPEAT FUNCTION TO BREAK UP THE TOTAL IRRIGATION TIME INTO CYCES THAT \MLL PROMOTE MAXIMUM SOIL ABSORPTION 3. ADJUST SPRAY HEADS TO ELIMINATE OVERSPRAY ONTO AREAS NOT UNDER THE CONTROL OF THE CUSTOMER. FOR EXAMPLE, POOL DECKS, PRIVATE PATIOS AND LOTS, AND STREETS AND SIDEWALKS. 4. MONITOR AND MAINTAIN THE SYSTEM TO MINIMIZE EQUIPMENT AND MATERIAL FAILURE. BROKEN SPRINKLER HEADS, LEAKS, UNRELIABLE VALVES, ETC. SHOULD BE REPAIRED AS SOON AS THEY BECOME APPARENT. 5. EDUCATE ALL MAINTENANCE PERSONNEL ON A CONTINUOUS BASIS OF THE PRESENCE OF RECYCLED WATER. PERSONNEL MUST BE INFORMED THAT RECYCLED WATER IS MENT FOR IRRIGATION PURPOSES ONLY, AND IS NOT APPROVED FOR DRINKING PURPOSES, HAND WASHING, CLEANING OF TOOLS, ETC. GIVEN THE HIGH TURNOVER RATE OF EMPLOYEES IN THE LANDSCAPING INDUSTRY, IT IS IMPORTANT THIS INFORMATION BE DISSEMINATED ON AN ALMOST DAILY BASIS. IT IS YOU, THE LANDSCAPE CONTIRACTOR WHO IS RESPONSIBLE FOR EDIJCATING EACH AND EVERY ONE OF YOUR EMPLOYEES. 6. OBTAIN PRIOR APPROVAL OF ALL PROPOSED CHANGES AND MODIFICATIONS TO ANY PRIVATE ON-SITE FACILITIES. SUCH CHANGES MUST BE SUBMITTED TO, AND APPROVED BY, THE DISTRICT ENGINEERING OFFICE AND DESIGNED IN ACCORDANCE \MTH DISTRICT STANDARDS. 7. ALL RECYCLED WATER SPRINKLER CONTROL VALVES SHALL BE TAGGED 'MTH IDENTIFICATION TAGS. A. TAGS SHALL BE WEATHERPROOF PLASTIC 3"X4" PURPLE IN COLOR \MTH THE WORDS "WARNING RECLAIMED WATER-DO NOT DRINK" IMPRINTED ON NO SIDE, AND "NO TOME EL AGUA" ON THE OTHER SIDE. IMPRINTED SHALL BE PERMANENT AND BLACK IN COLOR, USE TAGS AS MANUFACTURED BY T. CHRISTY ENTERPRISES OR APPROVED EQUAL. B. ONE TAG SHALL BE ATTACHED TO EACH VALVE AS FOLLOWS. 1. ATTACH TO VALVE STEM DIRECTLY OR \MTH PLASTIC TIE-'il'vRAP OR 2. ATTACH TO SOLENOID 'MRE DIRECTLY OR 'MTH PLASTIC TIE-'il'vRAP OR 3. ATTACH TO VALVE COVER WITH EXISTING VALVE COVER BOLT. 8. ALL SPRINKLER HEADS SHALL BE IDENTIFIED AS RECYCLED WATER SPRINKLER HEADS. 11. EACH AUTOMATIC CONTROLLER AND ITS ASSOCIATED EQUIPMENT SHALL BE IDENTIFIED 'MTH A SIGN BEARING THE WORDS "RECYCLED WATER USED FOR IRRIGATION" IN ENGLISH AND SPANISH, \MTH BLACK LETTERS 1" HIGH ON A PURPLE BACKGROUND. THE SIGN SHALL BE PLACED SO THAT IT CAN BE READILY SEEN BY ANY OPERATIONS PERSONNEL UTILIZING THE EQUIPMENT. BLACK LOGO r PURPLE BACKGROUND r 1" BLACK LETTERS 36" WA.RtelG RECYCLED WATER DO NOT DRN( RE YCLED WATER WASH LAVESE SUS AFTER CONTACTltG SPlES DE USAA 12" X 36" SIZE .032 ALUMINUM, .060 ABS PLASTIC OR STICK-ON VINYL SIGNS INSPECTION PROCEDURES I. CITY CONSTRUCTION INSPECTION SHALL INCLUDE: A. LOCATION OF PIPE LINES B. TRENCH DEPTH C. REQUIRED SEPARATION (HORIZONTAL AND VERTICAL) D. PIPE IDENTIFICATION POINT OF CONNECTION (P.O.C.) E. LOCATION AND IDENTIFICATION OF SPRINKLER HEADS. 1" BLACK LETTERS 2" BLACK LETTERS F. WARNING SIGNS AT THE SITE AND ON THE TRUCKS HAULING RECYCLED WATER (IF RECYCLED WATER IS USED FOR CONSTRUCTION). AN APPROVED LETTER REGARDING THE INSPECTION OF THE PROJECT SHALL BE OBTAINED FROM THE CITY AND DISTRICT. AND BE FORWARDED TO THE SAN DIEGO COUNTY DEPT. OF ENVIRONMENTAL HEALTH PRIOR TO FINAL INSPECTION APPROVAL. II . DISTRICT FINAL INSPECTION SHALL INCLUDE: A. COVERAGE TEST. AFTER COMPLETION OF THE SPRINKLER SYSTEM TO DETERMINE THE ADEQUACY OF COVERAGE ON THE APPROVED USE AREA AND PROTECTION OF AREAS NOT APPROVED FOR RECEIVING RECYCLED WATER. B. WARNING SIGNS AND LABELS C. QUICK COUPLING VALVES. D. ALL ASPECTS OF THE IRRIGATION CONDITIONS, INCLUDING 'MNDBLOWN SPRAY, RUNOFF AND PONDING. E. REQUIRED PROTECTION OF ALL RESIDENTIAL AREAS. F. REQUIRED PROTECTION OF WELLS, STREAMS, RESERVOIRS, ETC. G. CROSS CONNECTION 111. ANNUAL INSPECTION SHALL INCLUDE: A COMPLETE INSPECTION WHICH SHALL COVER PART A, PART B, AND PART G OF THE DISTRICT'S FINAL INSPECTION. REVISIONS MUST BE APPROVED BY PUBLIC HEAL TH ENGINEER, CITY ENGINEER ADN DISTRICT ENGINEER PRIOR TO IMPLEMENTATION IN THE FIELD. 6 ' N INSPECTION PROCEDURES BY THE LANDSCAPE ARCHITECT OF WORK INSPECTION OF THE PROJECT SHALL BE PERFORMED BY THE THE LANDSCAPE ARCHITECT OF WORK OR HIS DESIGNATED AGENT. REFER TO THE SPECIFICATIONS FOR THE SCHEDULE OF REQUIRED INSPECTIONS AND REQUIRED SUBMITTALS. FOLLO'MNG COMPLETION OF WORK. THE LANDSCAPE OF THE WORK WILL CERTIFY THAT THE INSTALLATION HAS BEEN COMPLETED BY SUBMITTING THE "FINAL LANDSCAPE CERTIFICATION FORM". A REQUEST FOR A FINAL LANDSCAPE INSPECTION BY THE CITY MUST ALSO BE MADE BY CALLING THE INSPECTION REQUEST LINE. "FINAL LANDSCAPE CERTIFICATION FORM" FAX TO: 760-944-8943 LANDSCAPE INSPECTION REQUEST PHONE LINE: 760-602~ AS-BUILT DRAWINGS AS-BUil T PLANS ARE REQUIRED BY THE ENGINEERING AND PLANNING DEPARTMENTS. ONE WEEK MINIMUM PRIOR TO FINAL IRRIGATION INSPECTION, CONTIRACTOR SHALL SUBMIT AS-BUil T DRAWINGS TO LANDSCAPE ARCHITECT OF WORK PER THE IRRIGATION SPECIFICATION REQUIREMENTS. FINAL MYLARS \MLL BE REQUIRED TO BE APPROVED AND SIGNED BY THE CITY PRIOR TO PLANNING DEPARTMENT SIGNING THE PERMIT CARD. COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEALTH RECYCLED WATER NOTES: REFER TO SHEET L 1.2 FOR TYPICAL DEPARTMENT OF ENVIRONMENTAL HEAL TH RECYCLED WATER NOTES. ZINC PLATTED 5/16" VANDAL RESISTANT BOLT W/ PIPE POST BRACKET (2 REQ'D) In Order to • w., ... _ REQ'(iLED WATER 1Nu DO NOT DIIN( I 110 TOIE EL AGUA WAIH HMlle lw"nlt CONTACDIQ .. --~,_... ...... e 18" X 18" SIZE .032 ALUMINUM, .060 ABS PLASTIC OR STICK-ON VINYL SIGNS .. _,...L.,._ """""' """' ... --~---w .. --==--=--==- "DO NOT DRINK" SIGN. SEE DETAIL ABOVE. 2-3/8" O.D. GALV. POST W/ GALV. FLAT END CAP SLOPE FOR DRAINAGE FINISH GRADE TYPCIAL SIGNS 1ST SUBMITTAL 07-03-07 2ND SUBMITTAL 07-24-07 RECYCLED WATER SYSTEMS (PRIVATE) ASPIRATIONS DAYCARE CENTER Cl) ~ co C\I CARLSBAD, CALIFORNIA PROJECT LOCATION OWNER/DEVLOPER SHEET INDEX THIS PROJECT IS LOCATED IN PARCEL 1 OF PARCEL MAP NO . 20174 (MS 05-05) ASSESSORS PARCEL NUMBER 213-1 10-15. ASPIRATIONS INC. SHEET TITLE SHEET NO. RJC NO. THE CALIFORNIA COORDINATE INDEX OF THIS PROJECT IS: 1966 CHERRYVVOOD ST VISTA, CA 92081 PHONE: (760) 521 -3919 RECYCLED WATER TITLE SHEET 1 · L 1.1 IRRIGATION PLAN 2 L 1.2 IRRIGATION EQUIPMENT LEGEND AND NOTES 3 L 1.3 N 338 E 1689 VICINITY MAP FARADAY C, ~ "2' 0 IRRIGATION SPRINKLER LEGEND AND D,ETAILS 4 L 1.4 IRRIGATION DETAILS 5 L1.5 PLANTING PLAN 6 L2.1 PLANTING MATERIAL LEGEND AND DETAILS 7 L2 .2 DECLARATION OF RESPONSIBLE CHARGE I HEREBY DECLARE THAT I AM THE LICENSED LANDSCAPE ARCHITECT OF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THIS PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS PROFESSIONS CODE AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRA\IVINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD AND THE SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENT.AL HEALTH IS CONFINED TO A REVIEW ONLY AND DOES NOT RELIEVE ME, AS THE LICENSED DESIGNER OF VI/ORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. a: <2 ~ rn c> w 0 ..., ..., 0 u ~ t ';.\.C1o>J ~<:) THESE PLANS HAVE BEEN PREPARED IN SUBSTANTIAL CONFORMANCE WITH THE APPROVED LANDSCAPE CONCEPT PLAN, FIRE PROTECTION PLAN, AND ALL CONDITIONS OF APPROVAL RELATED TO LANDSCAPING. .~ o>1-►I'-~►'-' ~,l<~Ql'-1 0 .., 0 ~ ~ ~ "' -<. NO SCALE ·· SITE PLAN ' I I ' I 1 ' 3: Ii I I ! ---. L •~ ~'t9"1!1'ooooooo0oooooooooooooooo0oo !00000 00000000000000000000000000000000000 1 ';:lt-__'./tt~g;Joooooooooooooooooooooooooooooooooo ~~ 0000000000000000000000000000000000 0 00000000000000000000000000000000000000000 1 o.o~~~~~~o!~~~~1ggg_g~, -- 000000000000000000000000000000000000000 ! 00000000000000000000000000000000000000 • ~==~o-ui:;-cruO"U"Utr0U"U"OU"l)"O"UO'"U"UO""OU"Ullu1 -----!·-i . -~-I I EL CAIIIINO_ REAL ~ ~EXISTING B"RECYCLEDWATER ---- ' ~ EXISTING 8" POTABLE WATER --I'll► "' ,., ► r FIRM: RJC ARCHITECTS ROBLES ADDRESSS: 320 LAUREL STREET SAN DIEGO, CA 92101 PRO.ECT SITE TEL.: /619) 239-9292 BY:~~-~ THOMA F. GARCIA DATE: 'I /n/o, RLA NO.:-'4=52=9c.._ ___ EXP. DATE: 12-31-08 NOTES: 1. PROVIDE CROSSOVER SLEEVE WHERE RECYCLED WATER IRRIGATION MAIN CROSSES POTABLE DOMESTIC WATER MAIN. 2. DRINKING FOUNTAIN IS PROTECTED FROM RECYCLED WATER MIST BY BEING CENTRALLY LOCATED IN AN AREA IRRIGATED WITH POTABLE WATER. on•RW-.. -RECYCLED WATER IRRIGATION MAINLINE @ 1" RECYCLED WATER METER @ 1" POTABLE WATER METER 0 60' 90' @ "DO NOT DRINK SIGNS" ·-: @ REDUCED PRESSURE BACKFLOW PREVENTER t!1J CROSS CONNECTION TEST STATION lllJ MASTER VAL VE [El PRESSUREREGULATOR SCALE: 1" = 60'-0" APPROVED FOR IRRIGATION AND PLANTING ONLY, ENGINEERING DEPARTMENT REVIEWED BY dkizL/Jd ENGINEERING PLANCHECKER COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEALTH COUNTY OF SAN DIEGO Deportment of Environmental Health Land and Water Quality Division ' GLENN LEEKS Environmental Health Specialist CARLSBAD MUNICIPAL WATER DISTRICT _/4)'~/~-n BILLPWMER DEPUTY CITY ENGINEER R.CE. 28176 •AS BU/Lr d~f-~ 9-2,0-0] DATE EXP 3/31 /08 I0-15-Qg DATE ~ AREAS OF RECYCLED WATER USE ~ AREAS OF RECYCLED WATER USE INSTALLED BY OTHERS INCLUDING PRECISE 1--T'..'..I T~L:.:E.:::: :=L:::AN==P::'Y=-=A.~P~c.:::::::::::A=:RCl\::='.::'1~1;::c.::::J'.:::::=======-l LOCATION OF PLANTING AREA. REVIE~ED jlY: t22Z2J AREAS OF POTABLE WATER USE rZv {; ( L-f • ~)..,;bf INSPECTOR DATE ~ CITY OF CARLSBAD MYLAR SUBMITTAL 08-30-07 RJC ARCHITECTS l---+---1------------------t----t---t---t---J l__LJ PLANNING DEP ARTMENT l---+---+----------------t----11----t----t----i RECYCLED WATER TITLE SHEET FOR: L 1 . 1 JOB NO. D608 DATE 07-03-07 SCALE AS SHO\\tl J 2 0 L A U R E L S T R ( [ f, SI\N 0l[G0, CA 92101 Tcl~~R~ 0. 45 PH 619.239 .9292 f'X 619.239 .9288 @ "1( ARCHITECTS, Inc. -2006 q /17 /01 DATE INITIAL EXP. 12-31-08 DATE ENGINEER OF WORK OWN BY: REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL CHKD BY: RVWD BY: ASPIRATIONS DAYCARE CENTER CARLSBAD, CA TG PROJECT NO. SDP06 -13 ':1·-Z.'6•01 I DAT E DRAWING NO. 451-6L POTABLE WATER P.O.C. DOWNSTREAM OF 1" POTABLE WATER METER AND RP BACKFLOW PREVENTER. SEE CIVIL DRAWINGS. FIELD VERIFY EXACT LOCATION. POTABLE WATER METER 1" BACKFLOW PREVENTER 1 1/2" MASTER VALVE 1 1/2" SERVICE LINE 2" ELEVATION ±306 FT. STATIC PRESSURE ±106 PSI. PRESSURE REG. SET AT: 70 PSI PROPOSED MAXIMUM FLOW = DESIGN OPERATING PRESSURE ±65 PSI \ AUTOMATIC IRRIGATION CONTROLLERS 'A' AND 'B' (WALL MOUNT INSIDE DUMPSTER ENCLOSURE) STATION A (RECYCLED WATER) 12 STATIONS 7 USED STATION B (POTABLE WATER) 16 STATIONS 16 STATIONS USED PLACE RECYCLED WATER STICKER ON CONTROLLER 'A'. HOURS OF OPERATION FOR CONTROLLER 'A' SHALL NOT CONFLICT WITH CONTROLLER USED FOR SLOPES. /20A, 115 VAC INDEPENDENT CIRCUIT POWER REQUIRED. FIELD VERIFY EXACT LOCATION. . __ .. ,, ...... " .... """ ' ' SHRUB T , ~ 1 ii . 7 .... r .(J) ,, !~ !! MAINLINE 1' SOUTH OF WALK-+--+-+--_,, i .,;--------'!.----\c'II 2" POTABLE WATER SERVICE LINE PER CIVIL DWGS. WATER EASEMENT i ::;=l@ , •· I $ __ , . -- SEWER EASEMENT ___,,, ___ _ ROAD STATION# 10+30 BACKFLOW PREVENTER 2" MASTER VALVE 1 1/2" ELEVATION ±308 FT. i STATIC PRESSURE ±105 PSI.! PRESSURE REG. SET AT: 70 PSI PROPOSED MAXIMUM FLOW ;::, I Po.. /'o.',j - 27 G.P.M. .. DESIGN OPERATING PRESSURE ±59 PSI --."'\ /. -----. , IRRIGATION BY MORROW DEVELOPMENT COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEALTH RECYCLED WATER NOTES• COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEAL TH RECYCLED WATER NOTES CONTINUED: STORM DRAIN-~---- EASEMENT -----------11 ·· I 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE CARLSBAD MUNICIPAL WATER DISTRICT'S RULES AND REGULATIONS. 2. DRINKING WATER FOUNTAINS AND DESIGNATED OUTDOOR EATING AREAS SHALL BE PROTECTED AGAINST CONTACT WITH RECYCLED WATER SPRAY, MIST, OR RUNOFF. 20. THE DESIGN AND LOCATIONS PROPOSED FOR RECYCLED WATER "DO NOT DRINK" SIGNS SHALL BE CALLED OUT ON THE PLANS. 2'L. WHEN RECYCLED WATER BECOMES AVAILABLE, AN ON-SITE USER SUPERVISOR SHALL BE DESIGNATED IN WRITING. THIS INDIVIDUAL SHALL BE FAMILIAR WITH PLUMBING SYSTEMS WITHIN THE PROPERTY, WITH THE BASIC CONCEPTS OF BACKFLOW/CROSS-CONNECTION PROTECTION, THE RECYCLED PURVEYOR'S RULES AND REGULATIONS AND THE SPECIFIC REQUIREMENTS OF A RECYCLED WATER SYSTEM. COPIES OF THE DESIGNATION, WITH CONTACT PHONE NUMBERS SHALL BE PROVIDED TO THE CARLSBAD MUNICIPAL WATER DISTRICT AND/OR THE SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH. 1ST SUBMITTAL 2ND SUBMITTAL MYLAR SUBMITTAL CONSTRUCTION CHANGE 07-03-07 07-24-07 08 -30-07 11-19-07 JOB NO. 0608 DATE 07-03-07 SCALE AS SHOWN \ • ., '\ .. ' •···,:/\ \ ; i'\ ._,. '\ ' '\ ' _·· '\ \ . i'\ ' • .. ___ --• '\ . ::·.. "'.: ., '-•• ··.:. : -,. . . .. / MAINLINE 3' • NORTHOF FENCE · ' . '\ ' .. '\ IRRIGATION MAINLINE AND APPURTENANCES LOCATIONS ARE DIAGRAMMATIC. ALL IRRIGATION EQUIPMENT SHALL BE INSTALLED WITHIN THE LIMIT OF WORK, 18" OFF ANY HARDSCAPE AND WITHIN PLANTING AREAS. PULL (2) SPARE WIRES AND THE COMMON FROM CONTROLLER 'B' TO VALVE BOX B12. MAKE ENDS WATERPROOF, TAPE AND LABEL AS "SPARE WIRES" AND PLACE INSIDE VALVE BOX. PULL (2) SPARE WIRES AND THE COMMON FROM CONTROLLER 'A' TO VALVE BOX A7. MAKE ENDS WATERPROOF, TAPE AND LABEL AS "SPARE WIRES" AND PLACE INSIDE VALVE BOX. IRRIGATION BY MORROW DEVELOPMENT PER PROJECT NO. CT-99-03, DWG NO. 430-4L. LONG-TERM MAINTENANCE BY OWNER. PLAN NORTH 0 10' 20' 30' .,., : SCALE: 1" = 20'-0" 3. BEST MANAGEMENT PRACTICES SHALL BE USED TO ELIMINATE OR CONTROL TO THE BEST EXTENT POSSIBLE PONDING, RUN-OFF, OVER-SPRAY AND MISTING. 4. HOSE BIBS ARE STRICTLY PROHIBITED. 5. CROSS-CONNECTIONS BETWEEN RECYCLED WATER LINES AND POTABLE WATER LINES ARE STRICTLY PROHIBITED. 6. NO SUBSTITUTIONS OF PIPE MATERIALS WILL BE ALLOWED WITHOUT PRIOR APPROVAL OF THE CARLSBAD MUNICIPAL WATER DISTRICT . 7. ALL MAINLINE PIPES SHALL HAVE WARNING TAPE PER CARLSBAD MUNICIPAL WATER DISTRICT'S RULES AND REGULATIONS. 8. HOURS FOR IRRIGATION WITH RECYCLED WATER ARE FROM 9:00P.M. TO 6:00 A.M. THE HOURS FOR IRRIGATION WITH DISINFECTED TERTIARY RECYCLED WATER MAY BE MODIFIED BY THE LOCAL AUTHORITY. IRRIGATION DURING PUBLIC USE PERIODS WITH DISINFECTED TERTIARY RECYCLED WATER SHALL BE UNDER THE SUPERVISION OF THE DESIGNATED USER SUPERVISOR. IRRIGATION WITH WATER OF A LESSER QUALITY THAN DISINFECTED TERTIARY RECYCLED WATER SHALL BE BETWEEN THE HOURS OF 9:00 P.M. AND 6:00 A.M. 9. BURIAL OF ALL WIRING AND PIPING SHALL MEET CARLSBAD MUNICIPAL WATER DISTRICT'S RULES AND REGULATIONS. 10. NON-DESIGNATED USE AREAS SHALL BE PROTECTED FROM CONTACT WITH RECYCLED WATER, WHETHER BY WINDBLOWN SPRAY OR BY DIRECT APPLICATION THROUGH IRRIGATION OR OTHER USE. LACK OF PROTECTION, WHETHER BY DESIGN, CONSTRUCTION PRACTICE OR SYSTEM OPERATION, IS STRICTLY PROHIBITED. 11 . IRRIGATION HEADS SHALL BE RELOCATED OR ADJUSTED TO MINIMIZE OR ELIMINATE OVER-SPRAYING ON SIDEWALKS, STREETS AND NON-DESIGNATED USE AREAS. 12. RECYCLED WATER QUICK COUPLING VALVES SHALL BE OF A TYPE DESIGNED FOR THE USE ON RECYCLED WATER DISTRIBUTION SYSTEMS PER CARLSBAD MUNICIPAL WATER DISTRICT'S RULES AND REGULATIONS. 13. ON RECYCLED WATER SYSTEMS, ALL APPURTENANCES (SPRINKLER HEADS, VALVE BOXES, ETC.) SHALL BE COLOR-CODED PURPLE PER AWWA GUIDELINES AND SECTION 116815 OF THE CALIFORNIA HEALTH AND SAFETY CODE. 14. ALL IRRIGATION PIPES SHALL BE STENCILED WITH THE WARNING, "NON-POTABLE OR RECYCLED WATER," COLOR-CODED (PURPLE) AND LAID WITH WARNING TAPE AND STENCILING ORIENTED TOWARD THE TOP OF THE TRENCH PER THE CARLSBAD MUNICIPAL WATER DISTRICT'S RULES AND REGULATIONS . 15. ON NEW ON-SITE SYSTEMS (POST-METER), POTABLE WATER, CONSTANT PRESSURE RECYCLED WATER AND SEWER LINES SHOULD BE PLACED A MINIMUM OF FOUR FEET APART OR AS DIRECTED BY THE PROJECT ENGINEER AND /OR REGULATORY AGENCY. MEASUREMENTS SHALL BE BETWEEN FACING SURFACES, NOT PIPE CENTERLINES. 16. CONSTANT PRESSURE RECYCLED WATER LINES SHALL CROSS AT LEAST TWELVE INCHES BELOW POTABLE WATER LINES AND MAINTAIN AT LEAST TWELVE INCHES CROSSING SEPARATION BETWEEN OTHER UTILITIES. 17. IF A CONSTANT PRESSURE RECYCLED WATER LINE MUST BE INSTALLED ABOVE A POTABLE WATER LINE OR LESS THAN TWELVE INCHES BELOW A POTABLE WATER LINE, THEN THE RECYCLED WATER LINE SHALL BE INSTALLED WITHIN AN APPROVED PROTECTIVE SLEEVE AS PER THE CARLSBAD MUNICIPAL WATER DISTRICT'S RULES AND REGULATIONS. 18. DEVELOPER/CONTRACTOR SHALL CONDUCT A CROSS-CONNECTION TEST AND COVERAGE TEST AS DIRECTED BY CARLSBAD MUNICIPAL WATER DISTRICT AND THE SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEAL TH PRIOR TO ANY USE OF RECYCLED WATER. 19. THE REQUIRED CROSS-CONNECTION INSPECTION SHALL BE DONE BY EITHER THE CARLSBAD MUNICIPAL WATER DISTRICT AND/OR THE SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH. COPIES OF INSPECTION REPORTS WILL BE FORWARDED TO THE NON-INSPECTING PARTY. APPROVED FOR IRRIGATION AND PLANTING ONLY, IN CASE OF EMERGENCY CONTACT ALAN HEIM AT (760) 521-3919 NAME PHONE NUMBER OR AFTER HOURS CONTACT ALAN HEIM AT (760) 521-3919 NAME PHONE NUMBER 22. ALL PUBLIC AND PRIVATE POTABLE WATER MAINS INCLUDING FIRE MAINS AND ANY WATER WELLS AND WATER COURSES WITHIN THE RECYCLED WATER PROJECT SHALL BE SHOWN ON THE PLANS . 23. CALL OUT ON THE PLANS IF THERE ARE OR ARE NOT DRINKING FOUNTAINS AND/OR DESIGNATED OUTDOOR EATING AREAS ON THIS SITE. 24. EDUCATE ALL MAINTENANCE PERSONNEL ON A CONTINUOUS BASIS OF THE PRESENCE OF RECYCLED WATER. PERSONNEL MUST BE INFORMED THAT RECYCLED WATER IS MEANT FOR IRRIGATION PURPOSES ONLY, AND IS NOT APPROVED FOR DRINKING PURPOSES, HAND WASHING, CLEANING OF TOOLS, ETC. GIVEN THE HIGH TURNOVER RATE OF EMPLOYEES IN THE LANDSCAPE INDUSTRY IT IS IMPORTANT THIS INFORMATION BE DISSEMINATED ON AN ALMOST DAILY BASIS. 25. A PHYSICAL SEPARATION SHALL BE PROVIDED BETWEEN ADJACENT AREAS IRRIGATED WITH RECYCLED WATER AND POTABLE WATER. SEPARATION SHALL BE PROVIDED BY DISTANCE, CONCRETE MOW STRIPS OR OTHER APPROVED METHODS. GENERAL IRRIGATION NOTES 1. REFER TO SHEET L 1. 1 FOR TYPICAL RECYCLED WATER NOTES. 2. SEE SHEET L 1.3 AND L 1.4 FOR ADDITIONAL IRRIGATION NOTES, LEGEND AND DETAILS. 3. ALL SPRINKLER HEADS, VALVE BOXES AND TAGS FOR THE RECYCLED WATER AREA SHALL BE COLOR CODED PURPLE. VALVES AND CONNECTIONS IN VALVES BOXES SHALL BE MARKED WITH RECYCLED WATER TAGS. 5. PIPING SHOWN WITHIN PAVING IS FOR CLARITY ONLY. ACTUAL MAINLINE AND LATERAL LOCATIONS TO BE A MINIMUM 12" OFF ADJACENT HARDSCAPE AND OTHER OBSTACLES (TYP). OUTSIDE LIMIT OF WORK IRRIGATION NOTES: 1. DAMAGED IRRIGATION EQUIPMENT OR PIPES WITHIN THE LIMIT OF WORK AREA WHICH SERVICE AREAS OUTSIDE THE LIMIT OF WORK SHALL BE REPAIRED OR REPLACED IN-KIND. 2. RELOCATE IRRIGATION VALVES AND OTHER EQUIPMENT AS NEEDED. 3. IRRIGATION WATER TO THE EXISTING SLOPE PLANTING AREAS SHALL REMAIN UNINTERRUPTED. AS NECESSARY, PROVIDE TEMPORARY MEANS OF WATERING SLOPE. 4. DAMAGED SHRUBS OR TREES THAT ARE IN DECLINE AS A RESULT OF LACK OF WATER SHALL BE REPLACED IN-KIND. ''AS BUILT" rlli•~-L DATE INCLUDING PRECISE l-....'.T.'...:IT~LE:.:::=l=~~O::Sc:;,~Mf=!::::::==::Awl~=='11~f/~:(========~ LOCATION OF PLANTING AREA REVI EWED BY: i1....f--( 4:-~tt INSPECTOR DATE RJC ARCHITECTS 1----+-----+-------------+----+---+---+-----t I SH2EET I CITY OF CARLSBAD I SHE7E TS I PLANNING DEPARTMENT ~=:'.==========:...;::::===: .3 2 0 l A U R E L S T R E E T, SA N DI E GO, CA 9 2 10 1 P II 6 1 9 . 2 J 9 . 9 2 9 2 f X 619 2~9.9280 © R.IC AACHITECTS. Inc. -2006 EXP. 12 -31 -08 ID-IS-O € DATE IRRIGATJON PLAN FOR: ASPIRATIONS DAYCARE CENTER CARLSBAD, CA L 1.2 l--+------1f---------------+---+--+---+----t I AP1z:zt \ ti n WI\-: n. ,,.08, _ PLANNING DATE ~=========:::;-;======;;:====~ DWN BY: TG PRO JECT NO. DR AWING NO. CH KD BY:__ SDP06-13 451 -6L RVWD B Y: DA TE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL Cl TY APPROVAL IRRIGATION EQUIPMENT LEGEND SYMBOL ® NOSYM. 'A: C2:l B' C2:l (W) EB NO SYM. ~ -------- DESCRIPTION POINT OF CONNECTION. RAIN SENSOR VALVE MANIFOLD RECYCLED WATER WALL MOUNT AUTOMATIC IRRIGATION CONTROLLER "A" POTABLE WATER WALL MOUNT AUTOMATIC IRRIGATION CONTROLLER "A" 1" POTABLE WATER METER EXISTING 1" RECYCLED WATER METER FULL PORT BALL VALVE REMOTE CONTROL WIRE. POTABLE WATER PRESSURE (MAINLINE) PIPE (SIZE PER PLAN). MANUFACTURER/ MODEL NO. (OR APPROVED EQUIVALENT -SEE NOTE 1 BELOW) HUNTER: MINI-CLIK W/ SENSOR GUARD MODEL# SG-MC HUNTER: ICC-1200SS (RW) HUNTER: ICC-1600SS (POT) WILKINS 850 SERIES PAIGE-ELECTRIC 14 AWG 600V. PACIFIC PLASTICS 1" r POTABALE WATER NON-PRESSURE (LATERAL) PACIFIC PLASTICS ·------· ------ IYl ~ ------- POTABALE WATER MAINLINE IN SLEEVE. WIRE SLEEVE POTABLE WATER LATERAL LINE IN SLEEVE MASTER CONTROL VALVE RECYCLED WATER 'DO NOT DRINK' SIGN. RECYCLED WATER PRESSURE (MAINLINE) PIPE (SIZE PER PLAN). PACIFIC PLASTICS PACIFIC PLASTICS PACIFIC PLASTICS RAINBIRD: 11/2" PESB-R SERIES (RECYCLED WATER) RAINBIRD: 11/2" PESB SERIES (POTABLE WATER) CARLSBAD WATER AGENCIES STANDARDS DRAWING PACIFIC PLASTICS "RECLAIMED WATER" PURPLE PIPE. ----.. _(:' --.. -.. _ RECYCLED WATER NON-PRESSURE (LATERAL) PACIFIC PLASTICS "RECLAIMED WATER" PURPLE PIPE. RECYCLED WATER MAINLINE IN SLEEVE. PACIFIC PLASTICS "RECLAIMED WATER" PURPLE PIPE. RECYCLED WATER LATERAL LINE IN SLEEVE PACIFIC PLASTICS "RECLAIMED WATER" PURPLE PIPE. REMOTE CONTROL VALVE. REMOTE CONTROL VALVE. PRESSURE REGULATOR NO SYM. TRENCH DETAIL NOSYM. WIRE CONNECTOR. NOSYM. RCV BOXES,PULLBOXES NOSYM. OTHER VALVE BOXES NOSYM. METALLIC LOCATOR/ WARNING TAPE NOSYM. VALVE I.D. TAGS QUICK COUPLING VALVE NO SYM. POTABLE SERVICE LINE CROSSING 1-1/2" BACKFLOW PREVENTER NOSYM. POTABLE WATER CROSSING. ITS1 CROSS-CONN. CONTROL TEST STATION. NOSYM. RISER CHECK VALVE NOSYM. THRUST BLOCKS VALVE CALLOUT: CONTROLLER VALVE DISCHARGE - (APPROX. GALLONS PER MINUTE) RAINBIRD PESB-R SERIES (RW) RAINBIRD PESB SERIES (POT) WILKINS 500C: 1-1/2" SPEARS ORI-SPLICE DS-100 W/ DS-300 SEALANT CARSON #1419-12 W/ LOCKABLE COVER (GREEN-POT, PURPLE-RW) CARSON #910-10 W/ LOCKABLE COVER (GREEN-POT, PURPLE-RW) CHRISTY'S DETECTABLE MARKING TAPE MOD.# TA-DT-6-PBI (RW) CHRISTY'S DETECTABLE MARKING TAPE MOD.# TA-DT-3-1 (POT) CHRISTY'S IRRIGATION ID TAGS MOD.# ID-STD-Y1 (POT) CHRISTY'S IRRIGATION ID TAGS MOD.# ID-MAX-P2-RC008 (RW) NELSON 7645 1-INCH THREAD SERIES AND 76411-INCH KEY AND 3/4"-INCH HOSE SWIVEL ELLS #8811 FOR NON-POTABLE USES (RW) RANBIRD44LRC 1~NCHTHREADW/44K 1~NCHVALVE KEY AND3/4"~NCH HOSE SV\AVEL #SH-1 AND 2049 LOCKING COVER KEY (POT) HUNTER HVC SERIES ~ 6 , ◄-t--_--STATION SEQUENCE t-jd VALVE SIZE REMARKS APPROX. WHERE SHOWN, FIELD VERIFY -INSTALL ON CMU WALL, VERIFY EXACT LOCATION. RUN CONDUIT TO CONTROLLER, ONE SENSOR PER CONTROLLER FOR ALL RCV'S, QUICK COUPLER VALVE$ APPROX. WHERE SHOWN, VERIFY EXACT LOCATION, PLACE RECYCLED WATER STICK ON CONTROLLER APPROX. WHERE SHOWN, VERIFY EXACT LOCATION SEE CIVIL DWGS APPROX. WHERE SHOWN, VERIFY EXACT LOCATION ' MAINLINE SIZE: FOR MAINLINE ISOLATION BURY ALONGSIDE MAINLINE (TYP.) PVC CL 315 W/ SCH 80 FITTINGS FOR 2" AND LARGER. PVC SCH 40 W/ SCH 40 FITTINGS FOR 1-1/2" AND SMALLER. PVC SCH 40 FOR 3/4" AND LARGER. PVC SCH 40 (PVC SCH 80 UNDER ROADS), 2X DIA. OF SLEEVED PIPE MIN. PVC SCH 40, 2X DIA. OF WIRE BUNDLE, MIN. PVC SCH 40 (PVC SCH 80 UNDER ROADS), 2X DIA. OF SLEEVED PIPE MIN. INSTALL APPROX. WHERE SHOWN APPROX. WHERE SHOWN, FIELD VERIFY. PVC CL 315 W/ SCH 80 FITTINGS FOR 2" AND LARGER. PVC SCH 40 W/ SCH 40 FITTINGS FOR 1'112" AND SMALLER. PVC SCH 40 FOR 3/4" AND LARGER. PVC SCH 40 (PVC SCH 80 UNDER ROADS), 2X DIA. OF SLEEVED PIPE MIN. PVC SCH 40 (PVC SCH 80 UNDER ROADS), 2X DIA. OF SLEEVED PIPE MIN. INSTALL NEXT APPROX. WHERE SHOW~, SIZE PER PLAN INSTALL NEXT APPROX. WHERE SHOWN, SIZE PER PLAN INSTALL NEXT APPROX. WHERE SHOWN; FIELD VERIFY FOR ALL PIPING BELOW GRADE. FOR ALL WIRE SPLICES INSTALL APPROX. WHERE SHOWN. INSTALL APPROX. WHERE SHOWN. INSTALL ABOVE MAINLINE AND ABOVE WIRES FROM CONTROLLER TO MAINLINE SEQUENCE VALVES PER PLAN, INCLUDE TAG FOR MASTER VALVE LOCKING COVER; QUICK COUPLER VAL)/ES FOR SUPPLEMENTAL WATER ' AT POTABLE SERVICE LINE AND METER SEE CIVIL DWGS; FIELD VERIFY AT ALL POTABLE WATER CROSSINGS W/RECYCLED WATER. RECYCLED WATER IRRIGATION CROSS CONECTION TEST STATION INSTALL ONLY WHERE LOW HEAD DRAINAGE OCCURS FOR ALL SUPPLY LINES 2" AND LARGER LEGEND NOTES: DETAIL 12/L 1.4 2/L 1.5 11/L1.4 11/L1.4 9/L 1.4 7/L1.5 7/L1.5 7/L 1.5 3/L 1.4 TITLE SHEET 7/L 1.5 7/L 1.5 3/L 1.4 3/L1.4 - 6/L 1.4 3/L 1.5 7/L 1.5 1/L 1.5 . 12/L1.5 -- 11/L1.5 9/L 1.5 -- 8/L 1.5 1. VERIFY SPECIFIED CONTROLLER AND IRRIGATION EQUIPMENT ARE NOT OBSOLETE AT THE TIME EQUIPMENT IS ORDERED. RW = RECYCLED WATER, POT= POTABLE WATER 1ST SUBMITTAL 07-03-07 2ND SUBMITTAL 07-24-07 MYLAR SUBMITTAL 08-30-07 RJC ARCHITECTS ~ J 2 U C A U R E C S r R E E r, PH. 619.239.9292 SAN DIEGO, FX. 619.239.9288 CA 921 □1 © RJC ARCHITECTS, Inc. -2006 JOB ~JO_ 0608 ,~ ,,/, ~f~ DATE 07-03-07 ft-1 MAS F. i!RCIA R.L.A. NO, 4529 EXP, 12-31-08 SCALE AS SHOWN SLEEVE CHART FOR IRRIGATION PIPE AND WIRES PIPE SCH 40 PVC CONTROLLER SCH 40 PVC SLEEVE SIZE WIRES SLEEVE SIZE (SCH 80 UNDER (SCH 80 UNDER ROADS) ROADS) 3/4" 2" 1-18 2" 1" 2" 19-24 2-1/2" 1-1/4" 2-1/2" 25-36 3" 1-1/2" 3" 37-48 4" 2" 4" 49-72 6" 2-1/2" 6" 3" 6" 4" 8" . PIPE SIZING CHART DIAMETER 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" -t•i·· .-,;, ·- SCH 40 0-8 GPM -- 9-13 GPM 14-23 GPM 24-32 GPM ••"'"'""""• -··~sCAA''••· ,,,, ~-,,, ... ,·· \. -:i;;••, ,lf . ~\ '~ ~ r A' i --"PrTl~ -n. \1, ~N . 4529!!> ;j '\ v'_,,. 1-}::! .,. ! ,, '1 · 1 2 o \ ct/'; ,· '•,,,, ,,.<' -•••• •·· ,,,,,,,, Of' CAL\ 1t ,,,,,,. ...... , .... , .. ,,. ........ 8/~/o7 DATE CLASS 315 30-50 GPM 50-70 GPM -- -····-· DATE INITIAL ENGINEER OF WORK GENERAL IRRIGATION NOTES 1. OWNER SHALL BE RESPONSIBLE FOR LONG-TERM MAINTENANCE OF SPECIFIED LANDSCAPE AREAS OF PROJECT. 2. IRRIGATION MAINLINE/ AND ALL EQUIPMENT ARE SHOWN DIAGRAMATICALL Y. INSTALL IN PLANTING AREAS. INSTALL MAINLINE 18" FROM ANY HARDSCAPE WHENEVER POSSIBLE. INSTALL VALVES IN SHRUB OR GRAVEL AREAS ONLY. 3. PRIOR TO COMMENCING ANY WORK, VERIFY LOCATION OF UNDERGROUND UTILITIES. FOR YOUR DIGALERT l.D. NUMBER CALL: UNDERGROUND SERVICE ALERT 1-800-227-2600 CALL TWO WORKING DAYS BEFORE WORK BEGINS 4. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FAMILIARIZE HIM OR HERSELF WITH ALL GRADE DIFFERENCES, LOCATION OF WALLS, RETAINING WALLS AND OTHER OBSTRUCTIONS. CONTRACTOR SHALL COORDINATE WORK WITH THE WORK OF OTHER TRADES FOR THE LOCATION AND THE INSTALLATION OF PIPE SLEEVES THROUGH WALLS, UNDER ROADWAYS, PAVING STRUCTURES & OTHER OBSTRUCTIONS. 5. LANDSCAPE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF PVC ELECTRICAL CONDUIT ELL (FOR CONTROL WIRE FOR IRRIGATION CONTROLLER) WITH ELECTRICIAN. 6. CONTROL WIRES UNDER PAVING SHALL BE INSTALLED IN PVC SLEEVES. COORDINATE SLEEVE INSTALLATION WITH OTHER TRADES TO ENSURE PROPER AND TIMELY INSTALLATION IN LOCATIONS REQUIRED. 7. CONTRACTOR SHALL NOT WILLFULLY INSTALL THE SYSTEM AS DESIGNED WHEN IT IS OBVIOUS IN THE FIELD THAT UNKNOWN OBSTRUCTIONS OR GRADE DIFFERENCES EXIST THAT WERE NOT KNOWN DURING DESIGN PHASE. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING CONDITIONS ON SITE AND CONTACTING THE LANDSCAPE ARCHITECT. WHEN PROBLEMS BECOME APPARENT, c·ONTRACTOR SHALL · MAKE APPROPRIATE ADJUSTMENTS TO ENSURE THAT IRRIGATION COVERAGE IS 100% IN ALL PLANTING AREAS AS ACCEPTED BY THE LANDSCAPE ARCHITECT. OTHERWISE, CONTRACTOR MUST ASSUME FULL AND COMPLETE RESPONSIBILITY FOR ANY AND ALL NECESSARY REVISIONS. 8. THE CONTRACTOR SHALL PROVIDE AN UP-TO-DATE AND COMPLETE "AS-BUILT" RECORD SET OF PRINTS WHICH SHALL BE CORRECTED DAILY AND SHOW EVERY CHANGE FROM THE ORIGINAL DRAWINGS. ONE WEEK PRIOR TO THE FINAL OBSERVATION, THE CONTRACTOR SHALL SUBMIT AS-BUILT INFORMATION TO THE LANDSCAPE ARCHITECT. ALLW9RK SHALL BE NEAT AND LEGIBLE. 9. ALL EXPOSED PIPE AND JOINTS SHALL BE SHADED WHENEVER TEMPERATURES EXCEED 100 DEGREES FAREN HEIT. 10. PROVIDE PULL BOXES FOR CONTROL WIRING AT ALL CHANGES OF DIRECTION AND WHERE RUNS EXCEED 200 FEET. SPLICES SHALL BE MADE ONLY IN PULL BOXES OR CONTROL VALVE BOXES. 11. CONTRACTOR SHALL BE RESPONSIBLE FOR BECOMING FAMILIAR WITH ALL UNDERGROUND UTILITIES AND PIPES. IF ANY HARDSCAPE, UTILITIES OR LANDSCAPE INDICATED ON THE APPROVED PLANS IS DAMAGED OR REMOVED DURING CONSTRUCTION, IT SHALL BE REPAIRED AND/OR REPLACED IN KIND AND EQUIVALENT SIZE PER THE APPROVED PLANS. 12. VERIFY ALL IRRIGATION AND ELECTRICAL POINTS OF CONNECTION PRIOR TO COMMENCING ANY WORK. APPROVED FOR IRRIGATION AND PLANTING ONLY, GENERAL IRRIGATION NOTES (CONT.) 13. CONTRACTOR SHALL REFER TO PLANTING PLAN FOR LOCATION OF TREES AND CONTAINER PLANTINGS, AND REFER TO SITE PLAN AND GRADING PLAN FOR LOCATIONS OF UNDERGROUND UTILITIES, PRIOR TO TRENCHING FOR IRRIGATION LINES. TREE LOCATIONS TAKE PRECEDENCE OVER IRRIGATION PIPING. STAKE TREE LOCATIONS PRIOR TO TRENCHING FOR PIPE. MAINTAIN A MINIMUM OF 5' CLEARANCE AROUND EXISTING TREES. 14. THE MAINTENANCE PERIOD WILL BEGIN ONLY UPON ACCEPTANCE IN WRITING BY THE LANDSCAPE ARCHITECT. IRRIGATION CONSTRUCTION NOTES 1. THESE SYSTEMS ARE DESIGNED TO SUPPLY A MINIMUM OF (30 PSI) AT THE SPRINKLER HEADS. 2. CONTRACTOR TO OBTAIN A STATIC WATER PRESSURE READING AT THE POINT OF CONNECTION PRIOR TO ORDERING ANY IRRIGATION MATERIALS AND PROCEEDING WITH INSTALLING THE IRRIGATION SYSTEM. IF THE WATER PRESSURE FOUND IS 60 PSI AT POINT OF CONNECTION, CONTRACTOR SHALL CONTACT THE LANDSCAPE ARCHITECT FOR FURTHER INSTRUCTIONS. 3. VERIFY EXACT LOCATION OF ALL UNDERGROUND UTILITIES AND ABOVE GROUND OBSTACLES WITHIN WORK AREA PRIOR TO START OF CONSTRUCTION. IF A CONFLICT EXISTS BETWEEN OBSTACLES AND THE PROPOSED WORK, CONTRACTOR SHALL PROMPTLY NOTIFY ARCHITECT TO ARRANGE FOR RELOCATIONS, IF REQUIRED, PRIOR TO START OF CONSTRUCTION. 4. ALL IRRIGATION LINES UNDER VEHICULAR PAVING SHALL BE SLEEVED WITH PVC SCH 80 PIPE AND SCH 40 UNDER PAVING (NON-ROADS). SLEEVE SHALL BE 2 TIMES THE DIAMETER OF PIPE TO BE SLEEVED. REFER TO SLEEVE CHART. 5. ALL ELECTRICAL WIRE UNDER VEHICULAR PAVING SHALL BE INSTALLED IN PVC SCH 80 CONDUIT AND SCH 40 UNDER PAVING (NON-ROADS). KEEP SEPARATE FROM WATER LINE SLEEVES INDICATED ON DRAWINGS. 6. ALL SPRINKLER HEADS SHALL BE INSTALLED AND ADJUSTED TO KEEP WATER OFF ALL PAVING, WALKS AND WALLS. 7. ALL LATERAL ENDS TO BE 3/4" UNLESS SHOWN OTHERWISE. 8. MANIFOLD GROUPS OF CONTROL VALVES, BALL VALVE AND QUICK COUPLER VALVE PER DETAIL2/L1.5. 9. CHECK VALVES SHALL BE INSTALLED AS REQUIRED TO PREVENT LOW HEAD DRAINAGE PER DETAIL 6/L1.5. "AS BUILT" ah~~-~ to-1 S-08 DATE INCLUDING PRECISE Tl TLE L J>s."10'.'JC.A.PE. AQcl\1ftG1 LOCATION OF RE;:;;yyl-r ~~{ PLANTING AREA. !1,i; ~ INSPECTOR DATE I SJET I CITY OF CARLSBAD I SH7TS I PLANNING DEPARTMENT IRR[GATION EQUIPMENT LEGEND AND NOTES F'OR: L 1.3 ASPIRATIONS DAYCARE CENTER CARLSBAD,CA AP~R~:( 12-~~I;\-'1 · Z,~-"'.., I (;,, n ~ • PLANNING . DATE DWN BY: TG PROJECT NO. DRAWING NO. DAfE INITIAL DATE INITIAL CHKD BY: REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL RVWD BY: SOP06-13 451-6L i I .. .!i ii Ii ,.--------------, ,--------------.. J I I I ( :>; ' ·.-;. -~! PLAN ''In-~-''/ ·-~ RAIN SENSORS 'A' & 'B' ---AUTOMATIC IRRIGATION ii ;;• CONTROLLERS A & B (WALL MOUNT) DUMPSTER ENCLOSURE 3/4" 0 PLASTIC ELECTRIC CONDUIT AND JUNCTION BOX TO RAIN SENSOR ~-CMUWALL ~-AUTOMATIC IRRIGATION CONTROLLER (INSIDE DUMPSTER ENCLOSURE -FIELD VERIFY) 2" 0 PLASTIC ELECTRICAL CONDUIT/ SWEEPS FOR CONTROLLER WIRES (PIPE SLEEVE TO ACCOMMODATE THE INSTALLATION OF THE WIRES) ------JUNCTION BOX -HARDWIRE CONTROLLER DIRECTLY TO BOX :; ·/ '.PJ..--1--+------3/4" 0 ELECTRICAL CONDUIT WI 120 VAC POWER ;~ INDEPENDENT 20A CIRCUIT ~~; .. , _,,---PLASTIC ELECTRICAL CONDUIT COUPLING i] ~ CONCRETE SLAB ON GRADE Pi<----'"-L.....:rr--,.,-----'c..._-:1 · . ., .4 ~----------DETECTABLE TAPE TO VALVES ~----------CONTROL WIRES (BUNDLE AND TAPE AT 10 FT INTERVALS NOTES: 1. SECURE ALL CONDUIT TO WALL WITH PIPE CLAMPS. 2. PLACE RECYCLED WATER STICKER ON 'A' CONTROLLER. AUTOMATIC CONTROLLER NTS RAIN SENSOR (SURFACE MOUNT PER MANUFACTURER'S INSTALLATION INSTRUCTIONS) FIELD VERIFY EXACT LOCATION 3/4" 0 PLASTIC ELECTRIC CONDUIT TO RAIN SENSOR FROM CONTROLLER. (USE PIPE CLAMPS WITH LAG SCREWS AND ANCHORS TO SECURE CONDUIT TO WALL SURFACE) CMUWALL RAIN SENSOR ON WALL MOUNTING NTS NOTE: INSTALL TWO (2) BUBBLER HEAD ASSEMBLIES PER PALM TREE. WHERE PALM TREES ARE LOCATED IN TURF AREAS, INSTALL TWO POP-UP BUBBLERS PER DETAIL 5/L 1.5. 6" WATERING BASIN BUBBLER HEAD ASSEMBLY\ PER DETAIL 6/L 1.5 \ .~~ <>- ROOTBALL 3" MAX. --------:-:-:-:-:-:-:-:-:-:-:-:-: PALM BUBBLER NTS I I MULCH LAYER FINISH GRADE SAND BACKFILL 12 L1.1 L1.4 CONNECT WIRES TO VALVE USING ORI-SPLICE CONNECTORS OR EQUAL FINISH GRADE VALVE I.D. TAG (RECYCLED WATER TAG WHERE OCCURS) __,___ 18" PVC PRESSURE PIP<=--+, CONTROL WIRE W/4' MIN.-J--tttt--"! EXTRA WIRE COILED, & TAPED AT 10 FT INTERVALS PVC SCH 40 TEE (SSS) -- BRICK OR CONCRETE SUPPORTS (END TO END UNDER PERIMETER OF VALVE BOX BOTTOM) NOTES: 1. ALL WIRE TO BE INSTALLED AS PER LOCAL CODE. VALVE BOX AND LID REMOTE CONTROL VALVE PVC SCH 80 UNION (THREADED) PVC SCH 80 THREADED NIPPLE -TYP. (LENGTH AS REQ'D) llr 12" llii!] PVC NON-PRESSURE PIPE PVC SCH 40 FEMALE ADAPTER (TYP.) (SxT) 3" MIN. DEPTH OF 314-INCH WASHED GRAVEL UNDISTURBED/COMPACTED SUBGRADE 2. PROVIDE EXPANSION COILS AT EACH WIRE CONNECTION IN VALVE BOX. (WRAP AROUND 112" PIPE 15 TIMES-REMOVE PIPE). 3. COMPACT SOIL AROUND VALVE BOX TO SAME DENSITY AS UNDISTURBED SOIL. 4. INSTALL VALVES IN SHRUB PLANTING BEDS. IN NO CASE SHALL VALVES BE LOCATED IN TURF OR PAVED AREAS. 5. USE TEFLON TAPE ON ALL THREADED CONNECTIONS . MASTER/ REMOTE CONTROL VALVE NTS PRESSURE REGULATER ---, PVC SCH 80 THREADED NIPPLE -TYP. (LENGTH AS REQ'D) FINISH GRADE ~ PVC SCH 40, 45° ELL_:-\' (SxS)-TYP , VALVE BOX AND LID PVC SCH 80 UNION (THREADED) PVC SCH 40 FEMALE ADAPTER (2 REQ'D) 3 L1.1 Ll.4 3" MIN. DEPTH OF 3/4-INCH WASHED GRAVEL .. . BRICK OR CONCRETE SUPPORTS PVC PRESSURE PIPE NOTE: USE TEFLON TAPE ON ALL THREADED CONNECTIONS. . ~·. (END TO END UNDER PERIMETER OF VALVE BOX BOTTOM) UNDISTURBED/ COMPACTED SUBGRADE PRESSURE REGULATOR IN VALVE BOX 6 NTS FULL PORT BALL VALVE ----~ PVCSCH80THREADED ---~ NIPPLE -TYP. (LENGTH AS REQ'D) FINISH GRADE -------, PVC SCH 40, 45° ELL (SxS)-TYP PVC PRESSURE PIPE NOTES: 1. INSTALLVALVES IN SHRUB PLANTING BEDS. IN NO CASE SHALL VALVES BE LOCATED IN TURF OR PAVED AREAS. 2. USE TEFLON TAPE ON ALL THREADED CONNECTIONS. FULL PORT BALL VALVE NTS L1.1L1.4 PVC SCH 80 UNION (THREADED) PVC SCH 40 FEMALE ADAPTER (2 REQ'D) 3" MIN. DEPTH OF 3/4-INCH WASHED GRAVEL BRICK OR CONCRETE SUPPORTS (END TO END UNDER BOX BO PERIMETER OF VALVE TTOM) TURBED/COMPACTED UNDIS SUBGRA DE @ 1ST SUBMITTAL 07-03-07 2ND SUBMITTAL 07-24-07 MYLAR SUBMITTAL 08-30-07 CONSTRUCTION CHANGE 11-19-07 JOB NO. 0608 DATE 07-03-07 SCALE AS SHOWN SPRINKLERS SYMBOL LCS RCS EST SST F H Q VAN DESCRIPTION MANUFACTURER/MODEL NO. Wl1800 NP COVER ( OR EQUIVALENT) (9 ~ €l @ ® 0 0· Q 6" POP-UP SHRUB SPRAY HEAD RAINBIRD 1806 SAM-PRS WI 15U SERIES NOZZLE @ 0 0 Q 6" POP-UP SHRUB SPRAY HEAD RAINBIRD 1806 SAM-PRS WI 12U SERIES NOZZLE @ 0 0 Q 6" POP-UP SHRUB SPRAY HEAD RAINBIRD 1806 SAM-PRS WI 10U SERIES NOZZLE e 0 6l 6" POP-UP SHRUB SPRAY HEAD RAINBIRD 1806 SAM-PRS WI BU SERIES NOZZLE e 0 6" POP-UP SHRUB SPRAY HEAD RAINBIRD 1806 SAM-PRS WI 5 SERIES NOZZLE 9 6" POP-UP SHRUB SPRAY HEAD RAIN BIRD 1806 SAM-PRS WI 4 SERIES NOZZLE 0 €) @ <ID "0 'O ·o "Q) 6" POP-UP LAWN SPRAY HEAD RAINBIRD 1806 SAM-PRS WI 15U SERIES NOZZLE 10 10 10 '(~ 6" POP-UP LAWN SPRAY HEAD RAINBIRD 1806 SAM-PRS WI 12U SERIES NOZZLE 0 0 G g 6" POP-UP LAWN SPRAY HEAD RAINBIRD 1806 SAM-PRS WI 10U SERIES NOZZLE e 0 q;; 6" POP-UP LAWN SPRAY HEAD RAINBIRD 1806 SAM-PRS WI BU SERIES NOZZLE e @ 6" POP-UP LAWN SPRAY HEAD RAINBIRD 1806 SAM-PRS WI 5 SERIES NOZZLE ii,} 6" POP-UP LAWN SPRAY HEAD RAINBIRD 1806 SAM-PRS WI 4 SERIES NOZZLE [:I 13] @ El . 0 □ • . □ IQ] 15 SHRUB SPRAY HEAD ON RISER RAINBIRD PA-8S Wl15U SERIES NOZZLE 0 D □" IQ] 12 SHRUB SPRAY HEAD ON RISER RAINBIRD PA-BS Wl12U SERIES NOZZLE 0 □ □ IQ] 10 SHRUB SPRAY HEAD ON RISER RAINBIRD PA-8S Wl10U SERIES NOZZLE El 11,1 ~ 8 SHRUB SPRAY HEAD ON RISER RAINBIRD PA-BS WIBU SERIES NOZZLE El 18 5 SHRUB SPRAY HEAD ON RISER RAINBIRD PA-8S Wl5 SERIES NOZZLE ~ 4 SHRUB SPRAY HEAD ON RISER RAINBIRD PA-8S Wl4 SERIES NOZZLE • POP-UP BUBBLER RAINBIRD 1806 SAM WI 1401 SERIES BUBBLER ■ TREE BUBBLER RAINBIRD PA-BS WI 1401 NOZZLE SERIES BUBBLER, TWO BUBBLERS PER TREE o/ PALM TREE BUBBLER RAINBIRD PA-8S WI 1402 NOZZLE SERIES BUBBLER, TWO BUBBLERS PER PALM TREE NOTES: 1. ADJUST SPRAY TO SUIT LOCAL CONDITIONS. 2. PROVIDE 1800 PRESSURE COMPENSATING SCREENS WHERE REQUIRED TO MINIMIZE OVERSPRAY ONTO PAVING, WALKS AND BUILDINGS. 3. ALL SPRINKLERS, VALVES AND VALVE BOXES CONNECTED TO THE RECYCLED WATER MAIN SHALL HAVE NP COVERS, NP HANDLES AND PURPLE VALVES BOXES. VAN=VARIABLE ARC NOZZLE F=FULL CIRCLE CST= CENTER STRIP V = CHECK VALVE RAD.= RADIUS SST= SIDE STRIP EST= END STRIP VAR= VARIABLE ADJ.= ADJUSTABLE NOZ.=NOZZLE STD.=STANDARDO RCS=RIGHT CORNER SPRAY LCS=LEFT CORNER SPRAY ROTORS SYMBOL Q H A F MANUFACT. MODEL NO./ DESCRIPTION G) @ G) © HUNTER HI-POP-UP-l-20-6P-ADV-1.0-18Q/18H/18N18F (SR NOZZLES) TURF SPRAY ® ® 0 ® HUNTER HI-POP-UP-l-20-6P-ADV-1.0-25Q/25H/25N25F (SR NOZZLES) TURF SPRAY ® @ (j}) @ HUNTER HI-POP-UP-l-20-6P-ADV-1.0-32Ql32H/32N32F (STD NOZZLES) TURF SPRAY IRRIGATION SPRINKLER LEGEND NTS - ""'""'"'""'"• RJC ARCHITECTS ,,,••<:~SCA.Pf'•,,,,,,,, .. ~--,'& . q· j~ '· !(Jc,:; rl)a S--;:.% ~320 LAUREL STREEC, P 11 . 6 1 S 239.9292 g u ,__ Y rTil SAN DIEGO, C X 619.239.9288 ~ ~ ~ ~ CA 92101 \* ~NO. 4529!b *f @ flJC ARCHITECTS, Inc. -2rJ06 \ J',,_ !It )::i .,. j '<, fr, · 12-o \ &'; .,· ...... <' 1 ,,•' ,,,,,,,, OF CAL\ ,,,,,,,' ,,,,,,,,.,,,.,,.,,,,,,,"'' 10-\S-08 DATE INITIAL DATE RAD. GALLONS PER MINUTE* DETAIL (FT) PSI LCS RCS EST SST F 112 114 VAN 15 30 .5 .5 .6 1.2 3.7 1.8 .9 VAR 5IL 1.5 12 30 2.6 1.3 .7 VAR 5IL 1.5 10 30 1.6 .8 .4 VAR 5IL 1.5 8 30 1.0 .5 .3 VAR 5IL 1.5 5 30 .2 .1 VAR 5IL 1.5 4 30 VAR 5IL 1.5 15 30 .5 .5 .6 1.2 3.7 1.8 .9 VAR 5IL 1.5 12 30 2.6 1.3 .7 VAR 5IL 1.5 10 30 1.6 .8 .4 VAR 5IL 1.5 8 30 1.0 .5 .3 VAR 5IL 1.5 5 30 .2 .1 VAR 5IL 1.5 4 30 VAR 5IL 1.5 15 30 .5 .5 .6 1.2 3.7 1.8 .9 VAR 6IL 1.5 12 30 2.6 1.3 .7 VAR 6IL 1.5 10 30 1.6 .8 .4 VAR 6IL 1.5 8 30 1.0 .5 .3 VAR 6IL 1.5 5 30 .2 . 1 VAR 6IL 1.5 4 30 VAR 6IL 1.5 -30 .25 5IL 1.5 -30 .25 13IL 1.5 -30 .5 13IL 1.4 TRAJECTORY GPM PSI RADIUS DETAIL -0.36, 0.78, VAR., 1.4 30 18 FT 4IL 1.5 -0.58, 1.1, VAR., 2.5 30 25 FT 4IL 1.5 -0.9, 1.2, VAR., 2.0 30 32 FT 4/L 1.5 2 L2.1 L2.2 ''AS BUILT" APPROVED FOR d~y-b IRRIGATION AND 10-I5.-oe PLANTING ONLY, DATE INCLUDING PRECISE TITLE: L N-\OSC--A>Pf.-ka\11~1 LOCATION OF REVIEWED BY: PLANTING AREA. ;1.,.,fj l., · 01~* /I.,;.~ INSPECTOR DATE I SH7TS I I S4ET I CITY OF CARLSBAD PLANNING DEPARTMENT IRRlGATION SPRINKLER LEG END AND DETAILS F'OR: L 1. 4 ASPIRATIONS DAYCARE CENTER CARLSBAD,CA . I AP1R~I' -Ar l n. C,.e>-e 1 6'"· E:11 PLANNING DATE --DWN BY: TG PROJECT NO. DRAWING NO. INITIAL DATE IN!llAL CHKD BY: clh~~ i · ~~ THOMAS F. GARIA R.L.A. NO. 4529 EXP. 12-31-08 DATE ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL RVWD BY: SOP06-13 451-6L LFINISH GRADE POTABLE WATER LINE ~-SLEEVE PER NOTE 2 RECYCLED WATER IRRIGATION MAINLINE • FINISH GRADE POTABLE MAINLINE (SEE CIVIL DRAWINGS) SECTION -POTABLE WATER 12" MINIMUM REQUIRED VERTICAL SEPARATION 10' MIN. SEPARATION TO POTABLE MAINLINE IN STREET RECYCLED WATER IRRIGATION MAINLINE SECTION -RECYCLED WATER NOTES: • <D "' 1. ALL RECYCLED WATER IRRIGATION PIPE AND SLEEVES SHALL BE PURPLE AND LABELED. 2. EXTEND SLEEVE 10' ON EITHER SIDE OF POTABLE WATER. 3. IF POTABLE WATER LINE HAS LESS THAN 36" COVER, RECYCLED WATER LINE MUST CROSS BELOW POTABLE WATER LINE. 4. REFER TO WATER AGENCIES' STANDARDS DESIGN GUIDE FOR PIPE SEPARATION REQUIREMENTS. POTABLE WATER LINE/RECYCLED MAINLINE WATER CROSSING NTS NOTE: SIDEWALK--, CURB -----._ POTABLE SERVICE LINE --.jl ~-,METER BOX W/ METER 24" 12" MINIMUM J_ 10' MINIMUM TO POTABLE MAIM..JNE IN STREET ~ ~ RECYCLED WATER IRRIGATION MAIM..JNE WI SlE~ ~ VERTICAL CLEARANCEOF 12" MINIMUM IS MAf'OATORY 1111-EN CROSSING PATH OF POTABLE WATER LINE. INSTALLATION OF RECYCLED WATER IRRIGATION MAIIII..INE 24" FROM FACE OF SIDEWALK WILL PROVIDE THE NECESSARY 10' HORIZONTAL CLEARANCE FROM POTABLE MAIM..JNE IN STREET. POTABLE SERVICE LINE CROSSING 12 NTS L1 .1L1.5 NOTE: INSTALL TWO (2) BUBBLER HEAD ASSEMBLIES PER TREE. \II/HERE TREES ARE LOCATED IN SHRUB AREAS, INSTALL ONE IN PERF. PIPE AND ONE ABOVE GRADE. \II/HERE TREES ARE LOCATED IN TURF AREAS, INSTALL TWO PERF. PIPES WITH BUBBLERS. ,-----6" WATERING BASIN BUBBLER HEAD ASSEMBLY PER DETAIL 6/L 1.5 3"MAX. 4" PLASTIC DRAIN GRATE NDS #11 (BLACK) 1" ABOVE MULCH LAYER BUBBLER HEAD MULCH LAYER FINISH GRADE PVC SCH 80 NIPPLE (TYP.) PEA GRAVEL FLEX RISER (MIPT X FIPT) (KING BROS. OR EQUIVALENT) 4" HEAVY DUTY PERF. PIPE W/ FILTER FABRIC WRAP 1-1--PVC SCH 40 TEE (SST) OR ELL (ST) AT LATERAL LINE TREE BUBBLER NTS i a: "' < I >-Cl z ~ UJ ~ "' ~ UJ z >-w:l: ~ GO en ,:, FINISH GRADE -~ 18" WITHIN LANDSCAPE, 36" UNDER ROADS AND PAVING ,---FOR RECYCLED WATER TRENCH, INSTALL ADDITIONAL DETECTABLE TAPE 12" ABOVE TOP OF MAINLINE APPROVED CLEAN BACKFILL (90% COMPACTION V\IITHIN LANDSCAPE, 95% COMPACTION UNDER PAVING) 12" WITHIN LANDSCAPE, 36" UNDER UNDER ROADS AND PAVING SCH 40 SLEEVES UNDER PAVING, SCH 80 UNDER ROADS _ _.,,. fil..-----l----~'--,tll;t---PVC NON-PRE.SSURE PIPE REMOTE CONTROL VALVE WIRE ALONGSIDE PRESSURE PIPE -BUNDLE & TAPE EVERY 10 FEET NOTES: .. ,, IL ~,iilJJ,,,--PVC PRESSURE PIPE II- SCH 40 SLEEVES UNDER PAVING, SCH 80 UNDER ROADS 1. \II/HEN TWO OR MORE PIPELINES ARE INSTALLED IN THE SAME TRENCH, THEY SHALL BE INSTALLED SO THAT EACH PIPELINE, VALVE, OR OTHER PIPELINE COMPONENT MAY BE SERVICED OR REPLACED WITHOUT DISTURBING THE OTHER. TRENCH IN HARDSCAPE/LANDSCAPE 7 NTS 1 45 DEGREE ELL '----'-Tr___,___., ,~ 90 DEGREE ELL THRUST BLOCKS NTS ,--7 I I I I I I I L J 1 7 I I I I I I I L __ J r""7r-~)...,f'.\; i ~-L~ :; ... I\ ~ ! ; 90 DEGREE ELL r;--, BACKFILL TRENCH '-.!J PER SPECIFICATIONS '2' CONCRETE THRUST ~ BLOCK, TYPICAL 0 MAINLINE PIPE 0 UNDISTURBED SOIL 2 L 1.1 L 1.5 NOTES: 1. ALL CONCRETE USED IN THRUST BLOCKS SHALL BE 470-C-2000. SUPPLY LINES 2" IN DIAMETER AND LARGER SHALL RECEIVE CONCRETE THRUST BLOCKING. BELL AND GASKET PIPE MAY USE PIPE RESTRAINT SYSTEMS. 2 . THRUST BLOCKS SHALL BE A MINIMUM OF 1 CUBIC FT. OF CONCRETE. PIPE SHALL NOT BE ENCASED IN CONCRETE. 3. ALL MAINLINES SHALL BE INSTALLED AND TESTED ACCORDING TO THE MANUFACTURER'S INSTALLATION SPECIFICATIONS. 4. ALL TRENCH DEPTH AND WIDTH SHALL BE PER THE SPECIFICATIONS. WRAP PLASTIC FITTINGS IN CONTACT WITH CONCRETE USING BLACK PIPE TAPE. ,---------3/4" PVC SCH 80 ELL ,---------3/4" PVC SCH 80 CLOSE NIPPLE ,--7 .,,----BALL VALVE WITH 1/4" FEMALE THREAD v---LINE SIZE x 3/4" PVC SCH I 80 TEE (SST) J ~-PURPLE PVC SCH 40 MAINLINE FROM WATER SOURCE .r L __ J PURPLE COLOR VALVE BOX AND LID 3" MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL BRICK OR CONCRETE SUPPORTS (END TO END UNDER PERIMETER OF VALVE BOX BOTTOM) ION CROSS-CONNECT CONTROL TEST S TATION @ NTS 1ST SUBMITTAL 07-03-07 2ND SUBMITTAL 07-24-07 2" IN SHRUB AREAS, FLUSH W/FINISH GRADE IN TURF AREAS FINISH GRADE • POP-UP ROTOR HEAD WITH NOZZLE ,---6" MIN., 8" MAX. FROM EDGE OF HARDSCAPE, WALL, ETC. j' r-:ri POP-UP BODY PVC SCH 80 NIPPLE (LENGTH AS REQ'D) ~~~----PVC SCH 80 NIPPLE (LENGTH AS REQ'D) PVC SCH 40 STREET ELL • PVC SCH 40 TEE (SST) OR ELL (ST) PVC NON-PRESSURE LI NE GEAR-DRIVEN POP-UP ROTOR NTS 2" IN SHRUB AREAS, FLUSH W/FINISH GRADE IN TURF AREAS ----,. POP-UP SPRAY OR BUBBLER HEAD FINISH GRADE ~--2" MIN., 3" MAX. FROM CURBS, WALKS, 6" FROM WALLS. • N PVC SCH 40 STREET ELL POP-UP BODY PVC SCH 80 NIPPLE (LENGTH AS REQ'D) PVC SCH 40 ELL PVC SCH 40 TEE (SST) OR ELL (ST) PVC NON-PRESSURE LINE POP-UP SPRAY/ BUBBLER HEAD NTS SPRAY OR BUBBLER HEAD ANTI-DRAIN CHECK -~ VALVE -SEE NOTE 2 PVC SCH 80 RISER (TYP.) 6"MIN. FROM HARDSCAPE OR WALL •· 'I -IV 11 I NOTES: 1. PROV! DE 1800 PCS \II/HERE REQ'D TO MINIMIMIZE OVERSPRAY ONTO PAVING. 2. PROVIDE HUNTER HCV ANTI-DRAIN CHECK VALVES ONLY WHERE LOW HEAD DRAINAGE OCCURS. FINISH GRADE PVC SCH 80 RISER-TYP. (LENGTH AS REQ'D) _;--PVC SCH 40 STREET ELL ----PVCSCH40ELL '\ (LENGTH AS REQ'D) ~ PVC SCH 40 STREET ELL PVC SCH 40 TEE (SST) OR ELL (ST) PVC NON-PRESSURE LINE SPRAY HEAD/ BUBBLER ON RISER (6\ ' NTS i,_, . 1 L 1.5 .,. ........... " ......... MYLAR SUBMITTAL 08-30-07 RJC ARCHITECTS .,,-~~-..... / ~ If . \ ' ~ ~\ ~ 3 2 0 L A U R E L S T R E E T, PH . 619 .23 9 .9292 ! ti .. ;;\ i. SA"' [JIEGO , FX . 6 1 9.239.9288 \i N . 4529 ;} CA 92101 © IIJC AIK HITECB, Inc. -2006 "'~ u',> \/ ,.. i -,._,.~ · tr-,;.,,,#,'/- "'"•.,, ~ C~\..\~ .,.,, ............. _ ............... JOB NO. 0608 ~1~{~ DATE 07-03-07 e/?>o•/0 1 DATE INITIAL SCALE TMAS F.RCIA R.L.A. NO. 4529 EXP. 12-31-0B DATE ENGlNEER OF WORK REVISION DESCRIPTION AS SHOWN NOTE: WHERE OCCURS, QUICK COUPLER SHALL BE OF A TYPE APPROVED FOR RECYCLED WATER USE. THREADEDREDBRASs--...1 6'"-12" COUPLING "'-"'-"" ,--QUICK COUPLING VALVE WITH ACME THREAD AND LOCKING COVER " 18" VALVE BOX W/LID FINISH GRADE 3" MINIMUM DEPTH OF 314-INCH WASHED GRAVEL BRICK OR CONCRETE SUPPORTS (END TO END UNDER PERIMETER OF VALVE BOX BOTTOM) --+--RED BRASS NIPPLE (LENGTH AS REQ'D) 1 CU. FT CONCRETE FOOTING ON COMPACTED SUBGRADE UNDISTURBED/COMPACTED SUBGRADE THREADED RED BRASS ELL PVC PRESSURE PIPE RED BRASS RISER (LENGTH AS REQ'D.) PVC SCH 40 COUPLER (Sxl) QUICK COUPLER NTS ( I I I QUICK-COUPLING VALVE \II/HERE OCCURS, / SIZE PER IRRIGATION EQUIPMENT LEGEND ~ PVC NON-PRESSURE PIPE (LATERALS-TYP ) REMOTE CONTROL VALVES, SIZE PER PLAN (TYP.) NOTE: LOCATE MANIFOLD IN PLANTER AREAS. DO NOT LOCATE IN TURF AREAS. VALVE MANIFOLD (TYP.} NTS (D PLUG INSTALLATION STEPS 1. INSERT WIRES THROUGH HOLES IN CASE OF BODY. 2. TVIIIST STRIPPED VI/IRES TOGETHER AND APPLY CRIMP SLEEVE WITH AN INDENT TYPE CRIMPING TOOL. TRIM EXCESS BARE WIRE. 3. FILL PLUG TO BRIM WITH DS-300 SEALANT (DS-100 ONLY). 4. INVERT BODY AND INSERT PLUG INTO BODY UNTIL IT SNAPS TIGHT. 5. PUSH WIRES ALL THE WAY INTO THE PLUG TO COMPLETELY SEAL THE CRIMP. 6. BE CERTAIN SEALANT HAS FORMED INTO ALL HOLES IN BODY (DS-100 ONLY). NOTE: FITS AWG #18, #14, #12 OR #10 WIRE []) CRIMP SLEEVE 0 ) BODY WIRES WIRE CONNECTOR NTS •As BUILT" APPROVED FOR IRRIGATION AND f1Mrr.) {-~ PLANTING ONLY, INCLUDING PRECISE T1 TLE: Le,i,io= eE: A~r.(EC.,1" LOCATION OF REVIEWED BY: PLANTING AREA. 1:.-r.-<.L( 4 -~ INSPECTOR /o-lS-08 DATE ll-G~ DATE I SH5ET I CITY OF CARLSBAD I SH7TS I PLANNING DEP ARTMENT IRRIGATION DETAILS FOR: L 1.5 ASPIRATIONS DAYCARE CENTER CARLSBAD, CA I APH~I( '1-z,t,.ol I Cr-E:tl--oft PLANNING DATE OWN BY: TG PROJECT NO. DRAWING NO. DAT[ INITIAL DAT[ INITIAL CHKD BY: SOP06-13 451-6L OTHER APPROVAL CITY APPROVAL RVWO BY: • ' \ ENTRY DRIVE COORDINATION NOTE: FINAL LOCATIONS AND QUANTITIES OF PALMS ALONG THE ENTRY DRIVE SHALL BE COORDINATED WITH THE ADJACENT PROJECT TO THE NORTH AND APPROVED BY THE CITY OF CARLSBAD PLANNING DEPARTMENT. CONTRACTOR SHALL OBTAIN FINAL APPROVAL OF QUANTITIES AND LOCATIONS FROM THE CITY OF CARLSBAD PLANNING DEPARTMENT PRIOR TO PLANTING. • J---:~"=:-:-----+-'R~Hu,A'.}__!11 '!:!D,!__,;;'S!.!:P:i:::R,_____' 5 AL ' 38 \ 5 GAL ·, 8 24' B.T.;H. DIAMOND CUT p 11 5GAL ' 25 5GAL 3 24" BOX * 9 5GAL ; 12 • RHA IND 'BAL' . PHO 0AC 'MED,' : PIT TOB 'VAR' I I! •□IE BlC . . ERIDE:F iPITTOB i 'W.D.'I: 0 ' "' N o · ' "' N 5GAL ' WAT~~EASEMENT~:T---+---~ 21-0" 0 1 36" BOX 18 1 GAL ; 348 5 GAL 5GAL : ·KOE PAN BEG ~IC HEM HYB b ' "' N f-_ ' 0 ~-'(.......'-_...__,_:::, YELLbW FLOWF.RI El I ffi I x )---°"8......,....--+-""C,.,IS,_,._P,,,U!.>R~---~ 5GAL _, >--1.:...:4'-----l---'L=-A"-'N,_'N""."'G"--.•---~ 5GAL 111 AGA 'Q.A.' 1 GAL ,•. l-----'4=-2 ---+-'L..-E,.,_P_,S,,_,C"-'Os<....!.'R.,,..,,,G.,__.' 5GAL ,1\ STORM DRAIN ,,<0 i0,ii,, EASEMENT . , :"ITL'\'iTEi:T PLANTING BY MORROW DEVELOPMENT PER PROJECT NO. CT-99-03, DWG NO. 430-4L. LONG-TERM MAINTENANCE BY OWNER. ~-------------------i:·i·/JJ.:~T}.l 1 ULM PAR 'T.G.' 60" BOX • •• ····~--••. ·····• .. • . I •. ·-;-:l:-·_: __ ":':~.:J __ :~:.:_I< i --,,l·~--:1--;_:/\.L'~-\ :!.f .t .. u,~,/'::·. .·• ~ . -,. _j~j~;\: ~:~{~_:;~- -l --,---1•-•• 1-.'.~--_,..• -• ••-•I , . ~' •~::~ :c~~fr~tr:.;~i~r:;-1~;~/;_ .-::-;-:'.-~• I 1• ., :ff~' ' I• 11 I FIRE PROTECTION ZONE A-1 FIRE PROTECTION ZONE A-2 FIRE PROTECTION ZONE A-3 ·:-~::~::>3}~\i-'.f:i:<::5::/<>;i{~~,:(:-:?i'.:{:-:~\:·'.\:(::S~-i~/~ft·:·. i.;, .Ji--,~; . ··;_Jil. -'..h,~-~/ :'.~\: , NATIVE (UNDISTURBED) -.__._.,.._ ... -,-~--._ .,-,.~ ., ....... ,·,., . .-.. , .• ,.,.,_<~·,, . '·'·.~·-·· .-.... ~~'""-. ·'-· -, · ... , ... , .... , ... , . IRRIGATION AND ·:;-,:\~:...::~:~-•--.-; .. :,-;.-.:•· ·--~;·::,:-;,-:-~_' .. /,:·>:·~·:l,'t.·:::-:<:-: ... ,:-~~1~:;:-~-\.'._~.\•·i".'-~:~·:~,\t'_;~,-; ·~ . _I :. :::._:::·L. 'i -.::-,,1::_':-'."'i::::.:::1 ~ •••• ) • ) ~· ~-• • ,, • •• _..., '' 1.> .... -<. '• i• • .h~-~-.;• 0 ~ ~. ,, ,.•• ?,r::~t~;~)t:~f }~~ .c;'ll-~~~ 2' SQ. CONCRETE PAVERS PER DETAIL 11/L2.2 TYP SYM ROOT BARRIER PER DETAIL 8/L2.2 TYP SYM '":!,, ~-,': '{J••·M ::;::\}:~-\~ SEWER EASEMENT .>---SDG&EEASEMENT BEGINNING OF FUEL MODIFICATION ZONES 9 5GAL 16 5GAL 13 5GAL CLY CAL DIS BUC BOU 'T.D.' 47 PHO 'M.Q.' '-:::-'-::-:-:-t-'---'-'-'='--'""-'-',e!,...-----{+ 5GAL 11 POD GRA 24" BOX 3 MET EXC 24" BOX 348 PEL PEL 1 GAL RED FLOWER 4 QUEAGR 24" BOX TIRE SWING AND MONKEY BAR PLAY EQUIPMENT WITH BARK MULCH SAFETY SURFACE 4 LOP CON 24" BOX + BENDERBOARD EDGING BY MORROW DEVELOPMENT PLANTING BY MORROW DEVELOPMENT PER PROJECT NO. CT-99-03, DWG NO. 430-4L. LONG-TERM MAINTENANCE BY OWNER. --......--=..:..:...:..=.....:...=.:....:.:..:::....:.:..:::....:.:..::.:...:...:::...::..::...:.::..=..=...:....=.:..:..:.:=.::..... __ t_,t:J;;1LI 0 PLAN NORTH 10' 20' 30' w-: SCALE: 1" = 20'-0" PLANTING NOTES: 1. REFER TO SHEET L2.2 FOR PLANTING LEGEND AND DETAILS. 2 PRIOR TO COMMENCING ANY WORK, VERIFY LOCATION OF UNDERGROUND UTILITIES. FOR YOUR DIGALERT 1.D. NUMBER CALL: UNDERGROUND SERVICE ALERT 1-800-227-2600 CALL TWO WORKING DAYS BEFORE WORK BEGINS 3. CONTRACTOR SHALL BE RESPONSIBLE FOR BECOMING FAMILIAR WITH ALL UNDERGROUND UTILITIES AND PIPES. IF ANY HARDSCAPE, UTILITIES OR LANDSCAPE INDICATED ON THE APPROVED PLANS IS DAMAGED OR REMOVED DURING CONSTRUCTION. IT SHALL BE REPAIRED AND/OR REPLACED IN KIND AND EQUIVALENT SIZE PER THE APPROVED PLANS . 4. MAINTENANCE: THE LANDSCAPE AREAS SHALL BE MAINTAINED FREE OF DEBRIS AND LITTER, AND ALL PLANT MATERIAL SHALL BE MAINTAINED IN A HEAL THY GROWING CONDITION. DISEASED OR DEAD PLANT MATERIAL SHALL BE SATISFACTORILY TREATED OR REPLACED PER THE CONDITIONS OF THE PERMIT. THE OWNER SHALL BE RESPONSIBLE FOR THE LONG-TERM MAINTENANCE OF SPECIFIED LANDSCAPE AREAS. 5. ALL PLANT MATERIAL SHALL BE MAINTAINED IN IT'S NATURAL FORM, AND SHALL NOT BE PRUNED OR SHEARED WITHOUT APPROVAL OF LANDSCAPE ARCHITECT . 6. THE RECOMMENDATION OF THE AGRICULTURAL SOILS REPORT FOR AMENDING SOIL SHALL SUPERSEDE THE RECOMMENDATIONS LISTED IN THE SPECIFICATIONS. CONTRACTOR SHALL SUBMIT AGRICULTURAL SUITABILITY AND FERTILITY ANALYSIS OF REPRESENTATIVE SOIL SAMPLES TO THE LANDSCAPE ARCHITECT AND OWNER'S REPRESENTATIVE PRIOR TO ANY PLANTING WORK. PER THE LANDSCAPE MANUAL, THE CITY INSPECTOR SHALL APPROVE THE TESTING AGENCY AND RESULTS. 7. THE MAINTENANCE PERIOD WILL BEGIN ONLY UPON ACCEPTANCE IN WRITING BY THE LANDSCAPE ARCHITECT. 8. OWNER SHALL BE RESPONSIBLE FOR LONG-TERM MAINTENANCE OF SPECIFIED LANDSCAPE AREAS OF PROJECT. 9. ALL LANDSCAPE AREAS SHALL BE GRADED TO PROVIDE A MINIMUM OF 2% POSITIVE DRAINAGE. 10. FINISH GRADE SHALL BE 3-INCHES BELOW TOP OF PAVING IN SHRUB AND GROUNDCOVER AREAS AND 1-INCH BELOW TOP OF PAVING IN TURF AREAS . 11. PLANT PLACEMENT AND PLANT MATERIAL SHALL BE APPROVED BY THE LANDSCAPE ARCHITECT PRIOR TO PLANTING. 12. ROOT BARRIER (24" HIGH NON-BIODEGRADABLE) SHALL BE INSTALLED (10' EACH SIDE OF TRUNK MEASURED PARALLEL TO HARDSCAPE x 24" DEEP) WHEN TREES ARE WITHIN 5' OF HARDSCAPE. INSTALL PARALLEL TO WALKS, WALLS, CURBS, AND BUILDING FOUNDATIONS. DO NOT ENCIRCLE TREE. INSTALL PER MANUFACTURER'S INSTRUCTIONS. 13. MINIMUM TREE SEPARATION DISTANCE: IMPROVEMENT MIN . DIST. TO TREE TRAFFIC SIGNALS OR STOP SIGNS 20 FT UNDERGROUND UTILITY LINES 5 FT ABOVE GROUND UTILITY LINES 10 FT DRIVEWAY (ENTRIES) 10 FT INTERSECTIONS (INTERSECTING 25 FT CURB LINES OF TWO STREETS) 14. QUANTITIES SHOWN ON PLANTING PLAN ARE FOR REFERENCE ONLY. PLANT SYMBOLS INDICATED SUPERCEDE QUANTITIES SHOWN. 15. PROVIDE 3" WALK-ON REDWOOD BARK MULCH LAYER FOR ALL TREE, SHRUB, VINE AND GROUNDCOVER AREAS EXCEPT WHERE SHOWN ON THE PLAN. DO NOT PLACE BARK MULCH ON SLOPES GREATER THAN 3:1. 16. NO PLANTING SHALL OCCUR UNTIL THE IRRIGATION SYSTEM IS INSTALLED AND OPERABLE. 17. ALL LANDSCAPE AREAS SHALL BE IRRIGATED BY MEANS OF A FULLY AUTOMATIC IRRIGATION SYSTEM AND WILL BE CONNECTED TO THE WATER SYSTEM WITH A BACKFLOW PREVENTER, FLOW SENSOR, MASTER VALVE, AND RAIN SHUT OFF VALVE. 18. THE TREES, SHRUBS, VINES AND GROUNDCOVER AREAS SHALL BE VALVED AND ZONED PER PLANT AND EXPOSURE REQUIREMENTS. 19. POP-UP IRRIGATION LEADS WILL BE USED AT PEDESTRIAN AREAS. 20. ALL PLANT MATERIAL SHALL BE APPROVED AT THE SITE BY THE LANDSCAPE ARCHITECT PRIOR TO PLANTING. ALL REJECTED PLANT MATERIAL SHALL BE REMOVED FROM THE SITE WITHOUT CHANGE IN CONTRACT AMOUNT OR TIME. 21 .CONTRACTOR TO COORDINATE PLANTING LIMIT OF WORK LINE WI OWNER. WEED ABATEMENT NOTE: 1. SPRAY ALL ACTIVELY GROWING WEEDS WITH ROUNDUP PRO OR APPROVED EQUIVALENT ACCORDING TO THE MANUFACTURER'S SPECIFICATIONS. 2. DO NOT APPLY CHEMICALS DURING HIGH WINDS OR UNDER CONDITIONS THAT WOULD ALLOW THE HERBICIDE TO DRIFT ONTO DESIRABLE PLANTINGS. 3. DO NOT TREAT AREAS WITHIN DRIPLINE OF ANY EXISTING TREES. 4. AFTER TREATING THE AREA WITH HERBICIDE, DO NOT IRRIGATE OR PLANT FOR A MINIMUM OF SEVEN DAYS. 5. CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL PUBLIC NOTICING NECESSARY FOR USING THE CHEMICALS. SLOPE REVEGETATION NOTES: SLOPES 6:1 OR STEEPER REQUIRING EROSION CONTROL MEASURES AS SPECIFIED HEREIN SHALL BE TREATED WITH ONE OR MORE OF THE FOLLOWING PLANTING STANDARDS: A. STANDARD #1 • COVER CROP/REINFORCED STRAW MATTING: COVER CROP SHALL BE A SEED MIX TYPICALLY MADE UP OF QUICK GERMINATING AND FAST COVERING GRASSES, CLOVERS, AND/OR WILD FLOWERS. SUBMIT THE SPECIFIC SEED MIX FOR CITY APPROVAL PRIOR TO APPLICATION. THE COVER CROP SHALL BE APPLIED AT A RATE AND MANNER SUFFICIENT TO PROVIDE 90% COVERAGE WITHIN (30) DAYS, TYPE OF REINFORCED STRAW MATTING SHALL BE AS APPROVED BY THE CITY AND STAKED TO THE SLOPE AS RECOMMENDED BY THE MANUFACTURER. REINFORCED STRAW MATTING SHALL BE REQUIRED WHEN PLANTING OCCURS BETWEEN AUGUST 15 AND APRIL 15. A COVER CROP AND/OR REINFORCED STRAW MAT MAY BE USED THE REMAINDER OF THE YEAR. B. STANDARD #2 · GROUND COVER ONE HUNDRED (100%) PERCENT OF THE AREA SHALL BE PLANTED WITH GROUND COVER KNOWN TO HAVE EXCELLENT SOIL BINDING CHARACTERISTICS (PLANTED FROM A MINIMUM SIZE OF FLATTED MATERIALS AND SPACED TO PROVIDE FULL COVERAGE WITHIN ONE YEAR). C. STANDARD #3 -LOW SHRUBS LOW SPREADING WOODY SHRUBS (PLANTED FROM A MINIMUM OF 2-314 INCH LINERS) SHALL COVER A MINIMUM OF SEVENTY (70%) PERCENT OF THE SLOPE FACE (AT MATURE SIZE). D. STANDARD #4 -TREES AND/OR LARGE SHRUBS TREES AND/OR LARGE SHRUBS SHALL BE (PLANTED FROM A MINIMUM OF 1 GALLON CONTAINERS) AT A MINIMUM RATE OF ONE (1) PER TOW HUNDRED (200) SQUARE FEET. SLOPES -6:1 OR STEEPER AND: A. 3' OR LESS IN VERTICAL HEIGHT AND ARE ADJACENT TO PUBLIC WALKS OR STREETS REQUIRE AT A MINIMUM STANDARD#1. B. 3' TO 8' IN VERTICAL HEIGHT REQUIRE STANDARDS #1 , #2 AND #3 C. IN EXCESS OF 8' IN VERTICAL HEIGHT REQUIRE STANDARDS #1, #2, #3 AND #4. AREAS GRADED FLATTER THAN 6:1 REQUIRE STANDARD #1 (COVER CROP) WITH TEMPORARY IRRIGATION WHEN THEY HAVE ONE OR MORE OF THE FOLLOWING CONDITIONS: A. SHEET GRADED PADS NOT SCHEDULED FOR IMPROVEMENTS WITHIN 6 MONTHS OF COMPLETION OF ROUGH GRADING. B. A POTENTIAL EROSION PROBLEM AS DETERMINED BY THE CITY. C. IDENTIFIED BY THE CITY AS HIGHLY VISIBLE AREAS TO THE PUBLIC OR HAVE SPECIAL CONDITIONS THAT WARRANT IMMEDIATE TREATMENT. RELOCATION OF UTILITIES NOTE: CONTRACTOR SHALL CONTACT THE LANDSCAPE ARCHITECT PRIOR TO BEGINNING LANDSCAPE WORK SO THAT LANDSCAPE ARCHITECT CAN REVIEW THE PROJECT UTILITY LOCATIONS AND REVISE PLANS ACCORDINGLY TO FULLY SCREEN ALL UTILITIES FROM VIEW. OUTSIDE LIMIT OF WORK PLANTING NOTE: DAMAGED PLANTING BEDS AND PLANTING OUTSIDE THE LIMIT OF WORK AREA SHALL BE REPLACED IN-KIND. '}\S BUil T" APPROVED FOR IRRIGATION AND ~J. ~ PLANTING ONLY, f 10-15-08 INCLUDING PRECISE TITLE: LMosc.-ee£-h9a:tti€61 LOCATION OF ~.'...'..=::..:.==~==::::::::::::::::=~~=========;..J PLANTING AREA. REVIEWED BY: t-i~{ l1 ~41t DATE INSPECTOR DATE 1ST SUBMITTAL 07-0J-07 2ND SUBMITTAL 07-24-07 RJC ARCHITECTS 1---+----+-----------+--+----j---t-~I SH6EET I CITY OF CARLSBAD I SHE7ETS I PLANNING DEPARTMENT ==::::'...::==========='.'.==~ MYLAR SUBMITTAL CONSTRUCTION CHANGE JOB NO. DATE SCALE 08-J0-07 11-19-07 0608 07-0J-07 AS SHO~ 3 2 0 L A U R E L S T R E E T, SA.Ii DIEGO, CA 92101 P H 519 739 9292 fX 619.2~9 9288 © PJC ARCHITECTS, Inc. -2006 EXP. 12-31-08 PLANTING PLAN FOR: ASPIRATIONS DAYCARE CENTER CARLSBAD, CA L2 . 1 t----+--+-----------+--+------+---1------1 1 APPf;fX~i 6:· ~ PLANNING DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL DWN BY: TG PROJECT NO. DRAWING NO, CHKD BY: SOP06-13 451-6L RVWD BY: SHRUB EXISTING FINISH GRADE AT-~ SLOPE (WHERE SHRUB CROWN 1" ABOVE FINISH GRADE Af;PLICABLE) NEW FINISH GRADE AT SLOPE (WHERE APPLICABLE) CURB OR PAVING IO'. (WHERE d APPLICABLE) ;.. DEPTH OF--~O) ROOTBALL ROOTBALL--/ -··-,,.--,,1=111::::111=111:: I 2x ROOTBALL DIA.MIN. 3" BARK MULCH LAYER- FEATHER AWAY FROM CROWN 4" HIGH WATERING BERM ALL AROUND SHRUB PLANT TABLETS 3" BELOW GRADE PLANT PIT W/ ROUGHENED SIDES BACKFILL MIX -50% NATIVE SOIL AND 50% AMENDMENTS (PUDDLE, SETTLE AND ELIMINATE AIR POCKETS) SHRUB/ GROUNDCOVER PLANTING 9 NTS L2.1 L2.2 BUILDING COLUMN EQ: .,,--VINE 3" BARK MULCH LAYER BENDER BOARD PER ii,1:~TIW,,~, t .} :::~:l>--L-3/-L2_.2 _______ ~AN~~COLUMN OR . ,._.,. .. _.,:,. · REMOVE NURSERY PLAN -VINE PLANTING AT BLDG. COLUMN VINE CROWN 1" ABOVE FINISH GRADE SET ROOTBALL TIGHT TO WALL OR FENCE NOTES: 1. SPREAD AND SECURE VINE TO WALL OR COLUMN W/ STIK 'N' TIES AND GREEN PLASTIC TAPE. 2. SECURE VINE TO FENCE GREEN PLASTIC TAPE. VINE PLANTING NTS STAKE PLANTING TABLET (3" MAX. BELOW GRADE 3" BARK MULCH LAYER - FEATHER AWAY FROM CROWN r 4" HIGH WATERING BERM ALL AROUND SHRUB FINISH GRADE BACKFILL MIX -50% NATIVE SOIL AND 50% AMENDMENTS (PUDDLE, SETTLE AND ELIMINATE AIR POCKETS) ~-----FEATHER BARK MULCH AWAY FROM TOP OF CONCRETE PAVER ~-----2' SQUARE x 2" THICK NATURAL COLORED CONCRETE PAVER ~---COMPACTEDSUBGRADE '-------AMENDED SOIL CONCRETE PAVERS NTS LEGEND 1. FRONDS TO BE TIED AND PROTECTED DURING SHIPMENT. UNTIE FRONDS AFTER 30 DAYS. OR AS DIRECTED BY PALM TREE EXPERT OR LANDSCAPE ARCHITECT. 2. TRUNK HEIGHT: MEASURED FROM ORIGINAL GRADE LEVEL AT BASE OF TRUNK TO TERMINAL BUD AT BASE OF FRONDS. TRUNK TO BE CLEAN', STRAIGHT AND FREE OF SCARS OR ROT. SET TRUNK PLUMB. 3. PLANT BASE OF TREE AT OR SLIGHTLY ABOVE FINISH GRADE. DO NOT BURY ANY PART OF TRUNK 4 4. FINISH GRADE 2~7 5. ROOTBALL: TO BE PROTECTED DURING SHIPMENT MINIMUM 3'-6'X 3'-6'X 4' DEEP. 6. WASHED COARSE CONCRETE SAND BACKFILL. DO NOT USE EARTH OR OTHER TYPES OF SAND. 7. 3" MULCH LAYER-FEATHER BACK MULCH AWAY FROM TRUNK 8. 4" DIA. BLACK PVC SLIP CAP, TOP 3" MAX. 9. 4" DIA. X 8' PERFORATED PVC PIPE -CENTER IN HOLE, WRAPPED WITH FILTER FABRIC 6 L, L, 12" -1 71 10. 12" DIA. X 8" DEEP AUGURED HOLE FILLED WITH 3/4" CRUSHED GRAVEL 11. END CAP "PHOENIX PALM TRUNKS TO BE DIAMOND-CUT. PALM PLANTING W/ BREATHER TUBE 6 NTS •.'~TURF . -·,•·"'.<: .. ·'·.;·>•·, 3" BARK MULCH LAYER }jjll}i/t ~~~~l~~/~~~RD PER ;'\}:]t,:)c· TREE TRUNK PLAN -TREE PLANTING IN TURF L2.1 L2,2 EXISTING FINISH GRADE AT SLOPE (WHERE APPLICABLE) 8' LODGEPOLE WOOD TREE STAKE LOOSELY ATTACH V.1.T. CINCH TIE SECURED TO STAKE W/ ONE GALVANIZED NAIL EACH (4 TIES REQ'D) NEW FINISH GRADE AT SLOPE (WHERE APPLICABLE) 6" WATERING BASIN FINISH GRADE---, 6'-8" AT PATH OF TRAVEL w --TREE TRUNK TREE CROWN 1" ABOVE FINISH GRADE 3" BARK MULCH LAYER -FEATHER BACK MULCH AWAY FROM TRUNK ~ -·,=rr'~!!J;,r;, \mW ·· PLANT TABLETS 4" BELow GRADE 00 :r: Tj: :u.::~ i,~ ~ ~ ~t ;l~~:{t: ~,;;-;::::.--<_-i, ~~11=f','1'---ROOTBALL rJ -:=I I =-I=_,:,:; 2xROOTBALL DIA.MIN. PLANT PIT WITH ROUGHENED SIDES BACKFILL MIX -50% NATIVE SOIL AND 50% AMENDMENTS (PUDDLE, SETTLE AND ELIMINATE AIR POCKETS) TREE PLANTING W/DOUBLE STAKING 7 NTS . . . . . . . ROOT BALL NOTES: ,-----3" BARK MULCH LAYER- FEATHER BACK MULCH AWAY FROM TRUNK ~--6" HIGH WATERING BERM ALL AROUND TREE BACKFILL MIX 1. ROOT BARRIER SHALL BE INSTALLED (10' EACH SIDE OF TRUNK MEASURED PARALLEL TO HARDSCAPE x 24" DEEP) WHEN TREES ARE WITHIN 5' OF HARDSCAPE U.N.O .. INSTALL PARALLEL TO WALKS, WALLS, CURBS, AND BUILDING FOUNDATIONS. DO NOT ENCIRCLE TREE. 2. SET TOP OF ROOT BARRIER BELOW BARK MULCH LAYER. L2.1 L2.2 TREE PLANTING W/ ROOT BARRIER (8\ . ' ' NTS L2, 1 L2.2 1ST SUBMITTAL 07-03-07 2ND SUBMITTAL 07-24-07 MYLAR SUBMITTAL 08-30-07 RJC ARCHITECTS CONSTRUCTION 11-19-07 CHANGE ~ 3 2 0 L A U R E L S r R E E r, f-' 1-1 • 0 1 :; L.'i9.9292 - SAN DIEGO, c X 6 1 9 i.~9.921:lil CA 92101 © RJC ARCHITECTS, Inc. -2()06 J08 NO. 0608 ~~i-~ DATE 07-03-07 TOMAS F. G RCIA R.L.A. NO. 4529 EXP. 12-31-08 SCALE AS SHOWN PLANT MATERIAL LEGEND SYMBOL BOTANICAL NAME COMMON NAME SIZE DETAILS QTY REMARKS TREES ERi DEF ERIOBOTRYA DEFLEXA BRONZE LOQUAT 24" BOX 7/L2.2 3 STANDARD TRUNK - KOE PAN KOELREUTERIA PANICULATA GOLDENRAIN TREE 36" BOX 7/L2.2 1 STANDARD TRUNK LOP CON LOPHOSTEMON CONFERTUS BRISBANE BOX 24" BOX 7/L2.2 4 STANDARD TRUNK MET EXC METROSIDEROS EXCELSA NEW ZEALAND CHRISTMAS TREE 24" BOX 7/L2.2 3 STANDARD TRUNK POD GRA PODOCARPUS GRACILIOR FERN PINE 24" BOX 7/L2.2 11 STANDARD TRUNK, SEE NOTE QUEAGR QUERCUS AGRIFOLIA COAST LIVE OAK 24" BOX 7/L2.2 4 STANDARD TRUNK ULM PAR 'T.G.' ULMUS PARVIFOLIA 'TRUE TRUE GREEN CHINESE ELM 60" BOX 7/L2.2 1 STANDARD TRUNK GREEN' PALMS PHO DAC 'MED' PHOENIX DACTYLIFERA 'MEDJOOL' MEDJOOL DATE PALM 24' B.T.H. 6/L2.2 8 MATCH HEIGHTS; PALMS TO BE DIAMOND CUT SELECTED PRIOR TO DELIVERY SHRUBS CIS PUR CISTUS PURPUREUS ORCHID ROCKROSE 5 GAL 9/L2.2 8 - DIE BIC DIETES BICOLOR FORTNIGHT LILY 5GAL 9/L2.2 25 - LIG JAP 'TEX' LIGUSTRUM JAPONICA 'TEXANUM' TEXAS PRIVET 5GAL 9/L2.2 48 - LAN 'N.G.' LANTANA 'NEW GOLD' NCN 5GAL 9/L2.2 14 - PIT TOB 'VAR' PITTOSPORUM TOBIRA VARIEGATA VARIEGATED TOBIRA 5GAL 9/L2.2 11 - PIT TOB 'W.D.' PITTOSPORUM TOBIRA 'WHEELER'S DWARF TOBIRA 5GAL 9/L2.2 12 - DWARF' - RHA IND 'BAL' RHAPIOLEPIS INDICA 'BALLERINA' BALLERINA INDIAN HAWTHORN 5 GAL 9/L2.2 38 - RHA IND 'SPR' RHAPIOLEPIS INDICA 'SPRINGTIME' SPRINGTIME INDIAN HAWTHORN 5 GAL 9/L2.2 9 - LEP SCO'RG' LEPTOSPERMUM SCOPARIUM NEW ZEALAND TEA TREE 5GAL 9/L2.2 42 - 'RUBY GLOW' PHO 'M.Q.' PHORMIUM 'MAORI QUEEN' FLAX 5 GAL 9/L2.2 47 - STR REG STRELITZIA REGINAE BIRD OF PARADISE 5 GAL 9/L2.2 9 - GROUNDCOVER AGA 'Q.A.' AGAPANTHUS 'QUEEN ANNE' LILY-OF-THE-NILE 1 GAL 9/L2.2 111 BLUE FLOWER BEG RIC BEGONIA 'RICHMONDENSIS' NCN 1 GAL 9/L2.2 18 - HEM HYB HEMERCALLIS HYBRID DAYLILY 5GAL 9/L2.2 348 EVERGREEN, YELLOW FLOWER --LAV ANG LAVAN DULA ANGUSTIFOLIA ENGLISH LAVENDER 5GAL 9/L2.2 150 - PEL PEL PELARGONIUM PEL TATUM IVY GERANIUM 1 GAL 9/L2.2 348 RED FLOWER --·-- LAWN HYB BER HYBRID BERMUDA PRO SPORTSFIELD MIX SOD -SEE SPECS VINES BOU 'T.D.' BOUGAINVILLEA 'TEXAS DAWN' NCN 5GAL 10/L2.2 13 -·~ CLY CAL CL YTOSTOMA CALLISTEGIOIDES VIOLET TRUMPET VINE 5GAL 10/L2.2 9 - DIS BUC DISTICTUS BUCCINATORIA BLOOD-RED TRUMPET VINE 5GAL 1 0/L2.2 16 --- NOTE: MAIN LEADER SHALL REMAIN IN TACT. TREES WITHOUT LEADERS SHALL BE REPLACED WITH APPROVED TREES. B.T.H. = BROWN TRUNK HEIGHT, O.C. = ON CENTER, NCN = NO COMMON NAME PLANT MATERIAL LEGEND NTS SECTION 1x6 BEND-A-BOARD PLASTIC HEADER BOARD BY EPIC PLASTIC OR EQ. COLOR: BROWN 12" STANDARD STAKE- USE PLATED SCREWS TO JOIN BOARD TO STAKE BEND A BOARD PLASTIC -- HEADER BOARD rn .rn I INSTALL PLASTIC STAKE@ 3' / -I ~ ~ ~ 2" O.C. USE PLATED SCREWS FOR ATTACHMENT PLAN BENDER BOARD NTS "'""""'""" ,,,,,,,•'~OSCAA';'',,,,, ,, \,. ,, /0ef-' f . "1 ~~--,, fl? Qt), o~\ ::w < ,,..,. _..~ §U'-·: Y'fT1~ -0 - \~ <?) . 4529c§' * j ',<l',..,_ Iv V "<"! '--, · 12-:> ~ _., .,,, )'ct ,,,' ,,,,,,,, Or CAL\ 't ,,,,,,,, ,,,,,,,,.,.,,.,,.,,,.,,,,,. )CJ-\<;-08 DATE INITIAL THERMAL EXPANSION GAP7 /\\ ~ I - JOINT CONNECTION SLIP JOINT -DO NOT SCREW THROUGH THE SLIP JOINT ~~ ~ ~~0 APPROVED FOR IRRIGATION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. DATE INITIAL DATE INITIAL DATE ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL ''AS BUILT" dl0rn6{ ~ 10-15-o5 DATE TITLE: L P-Jso &: Al'€-Ak\11-rr,;Cf REVIEWED BY: HL( l-,, f:-\\4 ll-'1.-=>~ INSPECTOR DATE I S1ET Ii CITY OF CARLSBAD I I SHEETS II 1 PLANNING DEPARTMENT PLANTING MATERIAL LEGEND AND DETAILS FOR L2.2 ASPIRATIONS DAYCARE CENTER CARLSBAD,CA I AP~~Ef' 4· EiL,df: Jl-•;-9S DATE PLANNING DWN BY: TG PROJECT NO. DRAWING NO. CHKD BY: SOP06-13 RVWD BY: 451-6L -- I