HomeMy WebLinkAboutCT 14-07; BEACHWALK AT ROOSEVELT; FINAL SOILS REPORT; 2020-11-23 (3) GEOTECHNICAL | ENVIRONMENTAL | MATERIALS All material herein © 2020 GeoTek, Inc. All Rights Reserved November 17, 2020 Revised November 23, 2020 PN 3447-SD3 Vesta Pacific Development 1818 First Avenue San Diego, California 92101 Attn: Mr. Geoff McComic Subject: Report of Post Grading Geotechnical Testing and Observation Beachwalk at Roosevelt 2685, 2687 and 2715 (Units 1 through 16) Roosevelt Street Carlsbad, California Dear Mr. McComic, In accordance with your request, GeoTek, Inc. is pleased to present results of our geotechnical testing and observation services provided for the utilities and streets (post grading) after rough grading at the subject project site. This report has been revised based on commentary from the City of Carlsbad, via email, requesting a compaction test location map. Construction Summary Rough grading of the subject building pads was completed under the observation of, and with selective testing by GeoTek, as reported in our December 2018 report (Reference 7). Selective testing and observations for utilities and private driveways were performed between September 19, 2018 and November 6, 2020 and were provided on a part-time, on-call basis. Based on our field observations and testing during site grading, we noted the following:  Field density tests were taken at periodic intervals and random locations to check the compaction efforts by the contractor.  Visual classification of the soil in the field, compared to the soil descriptions from the laboratory testing, was the basis for determining the maximum density and optimum moisture content applied to each field density test.  Sewer, storm drain, dry utilities, domestic and fire water utility backfill was tested.  Private driveway subgrade.  Public driveway approach and curb and gutter subgrade.  Public asphalt concrete patch back along public improvements. GeoTek, Inc. 1384 Poinsettia Avenue, Suite A Vista, CA 92081-8505 (760) 599-0509 •ffice (760) 599-0593 F1, www.geotekusa.com Vesta Pacific Development November 23, 2020 Report of Post Grading Geotechnical Testing and Observation Project No.: 3447-SD3 Beachwalk at Roosevelt – Carlsbad, California Page 2 Field Testing Our field density testing was performed in general accordance with ASTM Test Method D6983. Field density test results indicated that the fill materials were compacted to a minimum of 90 percent compaction relative to ASTM D1557 at the locations tested for utility trenches and storm drain/street/sidewalk and subgrade. Field density test results indicated that the fill materials were compacted to a minimum of 95 percent compaction relative to ASTM D1557 at the locations tested for curb and gutter subgrade, aggregate base and ASTM D 2950 for asphalt concrete. The field density test results are included in Table 1A-G for the various backfills/items as follows: Table 1A- Sewer, Table 1B -Water, Table 1C-Fire Line, Table 1D-Dry Utility, Table 1E- Street, Table 1F - Storm Drain, and Table 1G - Sidewalk. Approximate locations are shown on Figure 1. Laboratory Testing The laboratory testing pertinent to field density tests is the Moisture-Density Relationships for the various soils encountered: The laboratory maximum dry density and optimum moisture content for soil types tested were determined in general accordance with test method ASTM D1557. Laboratory test results are presented in Table A. TABLE A LABORATORY TEST RESULTS - ASTM D 1557 Soil Description Maximum Dry Density (pcf) Optimum Moisture (%) A Light Brown Silty Sand 132.0 7.0 B Light Brown Clayey Silt Fine Sand 123.7 9.2 C Brown Clayey Silty Fine Sand 122.9 12.2 D Brown Clayey Silty Sand - Mixed Base 127.4 9.9 E Mixed Brown Clay Silty Sand - Mixed Existing 129.0 9.8 F Import from City Lights Vista Med to Coarse Sand /DG 135.9 8.5 I Class II Recycle Base 118.5 12.0 AC Provided by Plant 145.0 - I I I I I A GEOTEK Vesta Pacific Development November 23, 2020 Report of Post Grading Geotechnical Testing and Observation Project No.: 3447-SD3 Beachwalk at Roosevelt – Carlsbad, California Page 3 Vesta Pacific Development November 23, 2020 Report of Post Grading Geotechnical Testing and Observation Project No.: 3447-SD3 Beachwalk at Roosevelt – Carlsbad, California References Selected References: 1. “Preliminary Geotechnical Evaluation, 2685 & 2687 Roosevelt Street, Carlsbad, California” by GeoTek, Inc. dated July 21, 2014 2. “Infiltration Evaluation, Beachwalk at Roosevelt, 2685, 2687 and 2715 Roosevelt Street, Carlsbad, California” by GeoTek, Inc. dated February 7, 2016 3. “Updated Preliminary Geotechnical Evaluation, Beachwalk at Roosevelt: CT 14-07, 2685, 2687 & 2715 Roosevelt Street, Carlsbad, California” by GeoTek, Inc. dated April 16, 2016 4. “Geotechnical Review of BMP Design, Beachwalk at Roosevelt, 2685, 2687 and 2715 Roosevelt Street, Carlsbad, California” by GeoTek, Inc. dated August 9, 2016 5. “Geotechnical Update, Beachwalk at Roosevelt, 2685, 2687 and 2715 Roosevelt Street, Carlsbad, California” by GeoTek, Inc. dated April 24, 2018 6. Structural Plans for Beachwalk at Roosevelt, by Gouvis Engineering Consulting Group, Inc., Plot date July 12, 2018 7. Report of Geotechnical Testing and Observations, Beachwalk at Roosevelt, Roosevelt Street, Carlsbad, California, by GeoTek, Inc. PN 3447-SD3, dated December 21, 2018 GEOTEK MR Carlsbad, LLC Beachwalk at Roosevelt Carlsbad, CA GeoTek, Inc. Sewer 11/17/2020 Project No.: 3447-SD3 Page 1 of 7 DATE Test No.Location Lot No. Sta No. Elev/ Depth Moisture Content (%) Dry Density (pcf) Soil Type Maximum Density (pcf) Test Type Relative Compaction (%) 9/19/18 1 Manhole Stat. 23+52 -3' 10.7 111.8 C 122.9 N 91 2 Manhole Stat. 23+52 -1.5' 10.9 116.3 D 127.4 N 91 9/20/18 3 Manhole Stat. 24+17 -3' 9.7 114.9 D 127.4 N 90 4 Manhole Stat. 24+17 -1.5' 9.3 115.6 D 127.4 N 91 9/24/18 5 Private St North Roosevelt -3' 13.0 116.9 B 123.7 N 95 6 Private St North Roosevelt -1.5' 12.3 119.2 B 123.7 N 96 7 Private St North Roosevelt SG 11.9 121.1 B 123.7 N 98 8 Private St N. Roosevelt Sidewalk -2' 11.7 119.4 B 123.7 N 97 9 Private St. N. Roosevelt Sidewalk SG 12.6 120.1 B 123.7 N 97 10 Private St. N. Roosevelt Adj. Lot 1 SG 12.3 115.4 B 123.7 N 93 11 Private St. N. Roosevelt Adj. Lot 3 SG 13.2 117.9 B 123.7 N 95 12 Private St. N. Roosevelt Adj. Lot 5 SG 11.9 115.8 B 123.7 N 94 9/26/18 13 Private South & Roosevelt -3' 11.0 118.8 B 123.7 N 96 14 Private South & Roosevelt -1.5' 11.7 119.8 B 123.7 N 97 15 Private South & Roosevelt SG 10.9 117.1 B 123.7 N 95 16 Private South Sidewalk -2' 13.0 117.0 B 123.7 N 95 17 Private South Sidewalk SG 14.1 118.9 B 123.7 N 96 18 Private South Adj. Lot 9 SG 12.9 117.4 B 123.7 N 95 19 Private South Adj. Lot 9 SG 12.1 118.2 B 123.7 N 96 TABLE 1A SUMMARY OF FIELD DENSITY TESTS Sewer Note: N = Nuclear Guage Test FG = Finished Grade Test All elevations are approximate MR Carlsbad, LLC Beachwalk at Roosevelt Carlsbad, CA GeoTek, Inc. Water 11/17/2020 Project No.: 3447-SD3 Page 2 of 7 DATE Test No.Location Lot No. Sta No. Elev/ Depth Moisture Content (%) Dry Density (pcf) Soil Type Maximum Density (pcf) Test Type Relative Compaction (%) 10/17/18 1 Roosevelt St. & S. Private St.SG 11.2 117.3 B 123.7 N 95 2 Roosevelt St. & S. Private St.SG 11.1 119.1 B 123.7 N 96 10/18/18 3 Roosevelt St. & S. Private St.SG 12.6 118.8 B 123.7 N 96 4 Roosevelt St. & S. Private St.SG 12.9 117.9 B 123.7 N 95 TABLE 1B SUMMARY OF FIELD DENSITY TESTS Water Note: N = Nuclear Guage Test FG = Finished Grade Test All elevations are approximate MR Carlsbad, LLC Beachwalk at Roosevelt Carlsbad, CA GeoTek, Inc. Fire Line 11/17/2020 Project No.: 3447-SD3 Page 3 of 7 DATE Test No.Location Lot No. Sta No. Elev/ Depth Moisture Content (%) Dry Density (pcf) Soil Type Maximum Density (pcf) Test Type Relative Compaction (%) 11/15/18 1 Fire line in North Entrance -2' 10.2 123.8 D 127.4 N 97 2 Fire line in North Entrance -1' 9.8 122.5 D 127.4 N 96 3 Fire line in North Entrance SG 9.1 123.0 D 127.4 N 97 12/10/18 4 4" Fire Line Adj Unit 8 SG 10.3 119.6 A 132.0 N 91 5 4" Fire Line Adj Unit 7 SG 11.2 119.3 A 132.0 N 90 6 4" Fire Line Adj Unit 4 SG 11.8 118.8 A 132.0 N 90 12/11/18 7 4" Fire Line Adj Unit 15 SG 11.6 120.2 A 132.0 N 91 8 4" Fire Line Adj Unit 14 SG 12.8 119.6 A 132.0 N 91 9 4" Fire Line Adj Unit 12 SG 11.7 120.9 A 132.0 N 92 TABLE 1C SUMMARY OF FIELD DENSITY TESTS Fire Line Note: N = Nuclear Guage Test FG = Finished Grade Test All elevations are approximate MR Carlsbad, LLC Beachwalk at Roosevelt Carlsbad, CA GeoTek, Inc. Dry Utilities 11/17/2020 Project No.: 3447-SD3 Page 4 of 7 DATE Test No.Location Lot No. Sta No. Elev/ Depth Moisture Content (%) Dry Density (pcf) Soil Type Maximum Density (pcf) Test Type Relative Compaction (%) 12/18/18 1 Gas Roosevelt St &S Driveway -2' 10.9 123.5 E 129.0 N 96 2 Gas Roosevelt St &S Driveway -2' 11.3 124.2 E 129.0 N 96 3 Gas Roosevelt St &S Driveway SG 11.9 124.2 E 129.0 N 96 4 Gas Roosevelt St &S Driveway SG 11.5 123.8 E 129.0 N 96 5 Gas Crossing Roosevelt SB SG 12.8 118.8 B 123.7 N 96 6 Gas Crossing Roosevelt NB SG 13.2 117.4 B 123.7 N 95 12/20/18 7 Gas Line Adj. Unit 16 SG 12.2 112.2 B 123.7 N 91 8 Gas Line Adj. Unit 15 SG 14.1 114.6 B 123.7 N 93 9 Gas Line Adj. Unit 8 SG 13.2 113.5 B 123.7 N 92 10 Gas Line Adj. Unit 9 SG 13.8 113.0 B 123.7 N 91 5/20/20 11 Bio-Rention Basin front of U 6&11 36' 7.5 116.1 D 127.4 N 91 12 Bio-Rention Basin front of Unit 5 36' 8.5 119.7 D 127.4 N 94 13 Between Units 14 & 15 SG 10.9 110.7 C 122.9 N 90 14 East of Unit 9 SG 9.1 119.8 D 127.4 N 94 15 Between Units 10 & 11 SG 12.1 110.6 C 122.9 N 90 16 East of Unit 1 SG 11.9 115.0 C 122.9 N 94 TABLE 1D SUMMARY OF FIELD DENSITY TESTS Dry Utilities MR Carlsbad, LLC Beachwalk at Roosevelt Carlsbad, CA GeoTek, Inc. Street 11/17/2020 Project No.: 3447-SD3 Page 5 of 7 DATE Test No.Location Lot No. Sta No. Elev/ Depth Moisture Content (%) Dry Density (pcf) Soil Type Maximum Density (pcf) Test Type Relative Compaction (%) 4/19/19 1 Roosevelt St adj NW corner SG 9.1 118.6 C 122.9 N 97 2 Roosevelt St adj N corner SG 10.1 117.2 C 122.9 N 95 3 Roosevelt St adj S corner SG 12.2 116.9 C 122.9 N 95 4 Roosevelt St adj SW corner SG 11.6 117.4 C 122.9 N 96 5 Roosevelt St adj NW corner AB 10.6 112.5 I 118.5 N 95 6 Roosevelt St adj N entrance AB 11.2 113.2 I 118.5 N 96 7 Roosevelt St adj S entrance AB 11.3 114.8 I 118.5 N 97 8 Roosevelt St adj SW corner AB 10.9 113.0 I 118.5 N 95 9 Roosevelt St SB adj NW corner -4" - 138.6 AC 145.0 N 96 10 Roosevelt St adj N entrance -4" - 144.1 AC 145.0 N 99 11 Roosevelt St adj S entrance -4" - 143.3 AC 145.0 N 99 12 Roosevelt St adj SW corner -4" - 142.3 AC 145.0 N 98 13 Roosevelt St adj NW corner AC - 139.3 AC 145.0 N 96 14 Roosevelt St adj N entrance AC - 138.8 AC 145.0 N 96 15 Roosevelt St adj S entrance AC - 141.3 AC 145.0 N 97 16 Roosevelt St adj SW corner AC - 141.9 AC 145.0 N 98 11/5/20 17 Street-Curb & Gutter AB 18.4 116.1 I 118.5 N 98 18 Street-Curb & Gutter AB 20.1 114.7 I 118.5 N 97 19 Street-Curb & Gutter AB 19.3 114.9 I 118.5 N 97 20 Street-Curb & Gutter AB 18.8 113.8 I 118.5 N 96 21 Street-Curb & Gutter AB 21.2 113.5 I 118.5 N 96 22 Street-Curb & Gutter AC - 139.4 AC 145.0 N 96 23 Street-Curb & Gutter AC - 139.0 AC 145.0 N 96 24 Street-Curb & Gutter AC - 141.2 AC 145.0 N 97 25 Street-Curb & Gutter AC - 138.7 AC 145.0 N 96 26 Street-Curb & Gutter AC - 139.9 AC 145.0 N 96 27 Street-Curb & Gutter AC - 140.1 AC 145.0 N 97 28 Street-Curb & Gutter AC - 140.4 AC 145.0 N 97 29 Street-Curb & Gutter AC - 139.3 AC 145.0 N 96 TABLE 1E SUMMARY OF FIELD DENSITY TESTS Street MR Carlsbad, LLC Beachwalk at Roosevelt Carlsbad, CA GeoTek, Inc. Storm Drain 11/17/2020 Project No.: 3447-SD3 Page 6 of 7 DATE Test No.Location Lot No. Sta No. Elev/ Depth Moisture Content (%) Dry Density (pcf) Soil Type Maximum Density (pcf) Test Type Relative Compaction (%) 6/1/20 1 Storm Drain crossline N Entrance SG 9.9 122.2 D 127.4 N 96 2 Storm Drain crossline N Entrance SG 8.3 124.3 D 127.4 N 98 TABLE 1F SUMMARY OF FIELD DENSITY TESTS Storm Drain I I I I I I I I I I I I BWR 16 LLC Beachwalk at Roosevelt Carlsbad, CA GeoTek, Inc. Sidewalk 11/17/2020 Project No.: 3447-SD3 Page 7 of 7 DATE Test No.Location Lot No. Sta No. Elev/ Depth Moisture Content (%) Dry Density (pcf) Soil Type Maximum Density (pcf) Test Type Relative Compaction (%) 10/19/20 1 N edge of Sidewalk SG 7.8 107.9 C 122.9 N 88 2 Near N edge of Sidewalk SG 8.9 108.3 C 122.9 N 88 3 N-Central Sidewalk SG 11.7 117.8 C 122.9 N 96 4 Center Sidewalk SG 11.0 118.2 C 122.9 N 96 5 S-Central Sidewalk SG 8.9 122.6 D 127.4 N 96 6 S edge of Sidewalk SG 9.6 115.5 C 122.9 N 94 10/26/20 1A Retest of test number 1 SG 11.7 115.0 I 118.5 N 97 2A Retest of test number 2 SG 11.3 115.9 I 118.5 N 98 7 S edge of Sidewalk SG 10.5 125.0 D 127.4 N 98 8 N area of Gutter SG 13.5 120.0 C 122.9 N 98 9 N central area of Gutter SG 14.4 118.7 C 122.9 N 97 10 S central area of Gutter SG 16.3 114.1 C 122.9 N 93 6A Retest of test number 6 SG 14.7 118.5 C 122.9 N 96 11/6/20 11 Front Sidewalk area SG 7.2 109.9 I 118.5 N 93 12 Roosevelt Street SG 8.4 109.3 I 118.5 N 92 13 South to North SG 9.1 108.2 I 118.5 N 91 14 South to North SG 8.0 109.7 I 118.5 N 93 15 South to North SG 12.2 113.6 I 118.5 N 96 16 Between 2711 & 2675 Roosevelt SG 11.8 112.8 I 118.5 N 95 17 Between 2711 & 2675 Roosevelt SG 12.4 114.6 I 118.5 N 97 18 Between 2711 & 2675 Roosevelt SG 12.4 118.5 I 118.5 N 100 19 Between 2711 & 2675 Roosevelt SG 10.4 112.2 I 118.5 N 95 TABLE 1G SUMMARY OF FIELD DENSITY TESTS Sidewalk LEGEND FIELD DENSITY TEST LOCATIONSEWERWATERFIRE LINEDRY UTILITIESSTREETSTORM DRAINSIDEWALK1384 Poinsettia Avenue, Suite A Vista, California 92081Vesta Pacific Development Beachwalk at RooseveltCarlsbad, California PN: 3447-SD3November 2020Figure 1Post- Grading Compaction Test Map-