Loading...
HomeMy WebLinkAboutPRE 2022-0003; 1369 FOREST AVENUE; Admin Decision LetterMarch 9, 2022 Masoud Mosallaie 1952 Alta Oaks Drive Arcadia, CA 91006 SUBJECT: PRE 2022-0003 (DEV 2022-0008)-1369 FOREST AVENUE APN: 156-110-83 {"Cityof Carlsbad E]FILE COPY fYJ,.,·J(J 3 / 10 /'2.2 Thank you for submitting a preliminary review for a 700 square foot (SF) one-story, attached accessory dwelling unit encroaching into the 20-foot-wide front yard setback on a 0.24 -acre vacant parcel with . frontage on Forest Avenue. In response to your application, the Planning Division has prepared this comment letter. Please note that the purpose of a preliminary review is to provide you with direction and comments on the overall concept of your project. This preliminary review does not represent an in-depth analysis of your project. It is intended to give you feedback on critical issues based upon the information provided in your submittal. This review is based upon the plans, policies, and standards in effect as of the date of this review. Please be aware that at the time of a formal application submittal, new plans, policies, and standards may be in effect and additional issues of concern may be raised through a more specific and detailed review. Planning: 1. General Plan and zoning designations for the property are as follows: a. b. General Plan: R-4, 4 dwelling units/ac Zoning: R-1, One-Family Residential 2. The project requires the following permits: a. Grading and building permits. 3. Plans. Please provide a fully dimensional site plan drawn to scale. a. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensioned setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. · b. Provide floor plans, elevations and cross sections drawn to scale. Community Development . Planning Division I 1635 Faraday Avenue Carlsbad, CA 92008-7314 I 760-602-4600 I 760-602-8560 f I www.carlsbadca.gov PRE 2022-0003 -1369 FOREST AVENUE March 9, 2022 Page 2 4. Climate Action Plan (CAP). New requirements related to the city's goals to reduce greenhouse gas (GHG) emissions will likely impact development requirements of this project. A formal application submittal will need to include a completed CAP Checklist (Form P-30) to determine what requirements will apply to the project. New GHG reduction requirements are related to energy efficiency, photovoltaic, electric vehicle charging, water heating and traffic demand management requirements, as set forth in the California Green Building Standards Code and in CMC Chapters 18.21, 18.30 and 18.51 which is available on the city's website at the following address: http:ljwww.gcode.us/codes/carlsbad/view.php?topic=18&frames=on To the extent that new GHG reduction requirements are in effect at the time of application for grading or building permits, the project will be required to comply with the effective requirements even if different than what is proposed in the project's planning approvals. GHG reduction requirements may impact, but are not limited to, site design and local building code requirements. If incorporating new GHG reduction requirements results in substantial modifications to the project after planning approvals are obtained, then prior to issuance of grading or building permits, the applicant may be required to submit and receive approval of a Consistency Determination or an Amendment application for the project through the Planning Division. 5. Vehicular access. Please specify the width and location of the proposed driveway and include details for any retaining walls. Please include top and bottom-of-wall measurements, as well as the overall wall height (below-grade footings are excluded from height measurement). 6. Title Report. Provide a title report dated within the last 6-months. Please also provide a map of the easements as prepared by the title company. 7. Single-family home. While the focus of the Preliminary Review submitted is the location of proposed attached ADU, staff has comments on the setbacks and access to the attached garage for the single-family home. The access and setback comments may impact the location of the ADU. The single-family home is subject to the standards of Carlsbad Municipal Code (CMC) Chapter 21.10, R-1, One-Family Residential Zone. Staff has the following comments on the preliminary design of the home: a. Building height. Pursuant to CMC Section 21.10.050 (R-1 zone), a single-family home in the R-1 zone is limited to a height of 30 feet and two stories if a minimum roof pitch of 3:12 is provided and 24 feet and two stories if less than a 3:12 roof pitch is provided. Pursuant to CMC Section 21.04.065, building height is defined as follows: PRE 2022-0003 -1369 FOREST AVENUE March 9, 2022 Page 3 Pursuant to CMC Section 21.04.065 (definition of "building height"), the height measurement is taken from existing or finished grade, whichever is lower, to the peak of the roof. Further, when nondiscretionary permits allow retaining walls, fill or other grading, which create a finished grade higher in elevation than the grade that existed prior to the retaining wall, fill, or grading, then building height shall be measured from existing grade. Please label the existing and finished grade on the cross sections and measure the height from the lower grade to the peak of the roof. The height must not exceed 24 feet if less than a 3:12 roof pitch is proposed or 30 feet if the roof pitch is 3:12 or greater. Please ensure the building height is measured from existing or finished grade, whichever is lower. b. Setbacks-Single-Family Home. Please label and dimension all required setbacks. Pursuant to CMC Section 21.10.100.C, a determination shall be made on which property lines of the buildable lot are the front, sides and rear for purposes of providing required yards. Please revise the site plan to designate the front, side and rear property lines/setbacks. The required side yard setback is 10% of the width of the lot, with a minimum of 5 feet and a maximum of 10 feet. Pursuant to CMC Section 21.04.263, the width of the lot is the horizontal distance of the line constituting the required front yard setback. The rear yard setback is double the interior side yard. See the Attachment A, Panhandle Lots for guidance. Setbacks-Attached ADU. The ADU cannot be located in the 20-foot-wide front yard setback. The required side and rear yard setback for the ADU is a minimum of four (4) feet. c. Lot Coverage. Provide a line calculation identifying the lot coverage of the proposed structures (total square footage of coverage area+ square footage of net area of the lot, i.e., excluding the panhandle portion of the lot). The lot coverage cannot exceed 40% of the net lot area. d. Parking. Pursuant to CMC Section 21.10.100.D.7, a panhandle lot shall have three non- tandem parking spaces with an approach not less than 24' in length with proper turnaround space to permit complete turnaround for forward access to the street (i.e., 24 feet, free and clear). The parking and access arrangement shall be designed to the satisfaction of the city engineer. These spaces shall be provided as a two-car garage (20'x20') with one tandem space or as a three-car garage. Please label the garage(s) on the site plan as either two or one car garage. Label the additional space(s) with the 24' turnaround. Please note, back up can be provided in the private access easement on the adjacent parcels lot if proof of shared access rights is provided. However, please note that depending on the front yard setback designation, the garage will either need to be setback a minimum 20 feet (if front yard setback) or 10% the width of the lot if it is a side yard setback. Either way, as currently proposed, the project does not comply with the setbacks. PRE 2022-0003 -1369 FOREST AVENUE March 9, 2022 Page 4 8. e. Garage. The attached garage appears to be encroaching into either the side yard or front yard setback. Please scale and label the setback and ensure it does not encroach into the setbacks. f. Driveway. An improved driveway shall be provided within the access portion of the lot from the street or public easement to the parking area on the buildable lot at least 20'. The driveway shall be constructed to accommodate public service vehicles with a minimum of two-inch thick asphalt concrete paving on proper base with rolled edges. g. Additional Corrections. Please note, additional corrections may be required upon review of a detailed site plan, floor plans, elevations, and cross sections. Accessory Dwelling Unit (ADU). The ADU is subject to the standards of Carlsbad Municipal Code (CMC) Chapter 21.10, R-1, One-Family Residential Zone, and State Law as summarized in the Accessory Dwelling Unit Informational Bulletin IB-111 (Attachment B). Staff has the following comments on the preliminary design of the ADU: a. Building Height. Attached AD Us are subject to the limits specified under the applicable zone. Please provide elevations for the ADU and indicate and dimension the height and the roof pitch. b. Parking. One parking space is required for the proposed ADU and may be located within the building setbacks or on the driveway as a tandem space. Please label and dimension the ADU parking space. Parking must be a minimum of 8.5 feet wide and 170 square feet. If the ADU is less than 500 square feet, it qualifies as a Junior Accessory Dwelling Unit (JADU) and parking is not required. c. Lot Coverage. If the proposed ADU is greater than 16' in height and over 800 square feet in area, please include the ADU in the lot coverage calculation. If the ADU is less than 16' in height or less than 800 square feet in area it does not need to be included in the lot coverage calculation. d. Additional Corrections. Please note, additional corrections may be required upon review of a detailed site plan, floor plans, elevations, and cross sections. 9. Variance. A Variance for reduced setbacks would not be supported by staff for the following reasons: a. Staff has determined that the single-family dwelling and accessory dwelling unit can be designed on the subject .24-acre vacant lot to comply with the development standards. The design will need to be adjusted and the size of the proposed single-family dwelling may need to be reduced. PRE 2022-0003 -1369 FOREST AVENUE March 9, 2022 Page 5 b. The drainage path and panhandle shape of the lot do not qualify as special circumstances that deprives the property of privileges enjoyed by others in the vicinity and under the same zoning classifications. 1373 Forest Avenue is also a panhandle lot and contains the same path as this project. The lot contains a single-family dwelling and garage permitted in 2019 which meets the setback requirements. The lot also appears to have additional area to build an accessory dwelling unit that will meet setback requirements. c. Although the doctors note submitted with the Preliminary Review supports the claim that the ADU cannot be designed as a two-story structure, the proposed ADU and main dwelling unit proposed on the vacant lot can be redesigned to meet the setbacks. Therefore, staff is not supportive of locating the ADU in the front yard setback. If the property line closest to the ADU is designated as a side yard setback, a four-foot-wide setback is allowed for the ADU. However, the property line closest to the attached garage would qualify as the front property line and the garage would need to be set back 20 feet from the property line. All necessary application forms, submittal requirements, and fee information are available at the Planning counter located in the Faraday Building at 1635 Faraday Avenue or on line at www.carlsbadca.gov. You may also access the General Plan Land Use Element and the Zoning Ordinance online at the website address shown; select Department Listing; select Planning Home Page. Please review all information carefully before submitting. Land Development Engineering comments: Land Development Engineering Division staff has completed a preliminary review of the above- referenced project. Prior to formal application submittal the following items must be adequately resolved/ addressed: 1. Complete a Stormwater Standards Questionnaire. This questionnaire will guide you and the City in determining what type of reports and storm water mitigation must be completed to satisfy state and City storm water quality requirements. The questionnaire can be printed from the following website link: https://www.carlsbadca.gov/home/showpublisheddocument/604/637659282326670000 2. A grading plan will be required. 3. A preliminary hydrology study will be required to determine the pre-development and post- development discharge flows. Provide preliminary recommendations to mitigate any increase in flows. 4. A recent Preliminary Title Report (PTR) will be required with formal project application submittal. All easements and encumbrances identified in the PTR must be indicated on the site plan 5. Show complete property boundary data on the site plan, including bearings and distances. 6. Provide a typical street cross section of Forest Avenue showing existing improvements. PRE 2022-0003-1369 FOREST AVENUE March 9, 2022 Page 6 7. On the site plan, show and identify all existing surface improvements (curb, gutter, sidewalk, paving, manholes, inlets, streetlights, adjacent driveways, vaults, transformers, etc.) at the project frontage and within 25 feet. 8. Provide multiple cross-sections of the site to demonstrate differences in grade, including adjacent properties. 9. Indicate the volume of grading (cut, fill, import, export, remedial) proposed for the project in cubic yards. 10. Use NGVD 29 datum for vertical control for all design elevations per city Engineering Standard Volume 1, Chapter 2. 11. Show proposed finished floor elevations for structures. 12. Show existing and proposed water services and sewer laterals. 13. A Neighborhood Improvement Agreement will be required. 14. Show that there is sufficient room for a vehicle turning into and out of the garage. 15. Please be advised that in order to make a more in-depth review of the proposed development, a more complete design of the project is required. Fire: 1. NFPA 13D Fire Sprinklers required throughout the entire ADU and future attached home. Building: 1. Show details for one-hour fire resistance rated wall(s) separating the ADU from the main residence for this attached ADU. 2. Show details for one-hour fire resistance rated wall(s) separating the ADU from the main residence for this detached ADU that is closer than 5' to the property line. 3. Sewer design with fixture unit counts for entire sewer line, including the new house if the ADU ties into the existing sewer line prior to the sewer main connection. 4. Electrical load calculations and single line diagram for entire electrical design, including the new house. Solar required for the new house. 5. Carlsbad Climate Action plan details on plans to be coordinated with the CFl-R energy documents. 6. Single line diagram for proposed gas fixtures including the new house fixtures. 7. Separate HVAC will be required for the ADU. PRE 2022-0003 -1369 FOREST AVENUE March 9, 2022 Page 7 If you would like to schedule a meeting ~o discuss this letter with the commenting departments, please contact Lauren Yzaguirre at the number below. You may also contact each department individually as follows: • Planning Division: Lauren Yzaguirre, Associate Planner, at (442) 339-2634 • Land Development Engineering: Allison McLaughlin, Project Engineer, at (442) 339-2732 • Fire Department: Randy Metz, Fire Marshal, at (442) 339-2661 Sincerely, DON NEU, AICP City Planner DN:LY:cf Attachments: A. Panhandle Lots B. IB-111, Accessory Dwelling Units c: Allison McLaughlin, Project Engineer Randy Metz, Fire Prevention File Copy Data Entry/Laserfiche