Loading...
HomeMy WebLinkAboutDWG 473-2SW; SDP 06-12A; BMP SITE PLAN - TAVARUA SENIOR APARTMENTS; 01i ! . )j,";. , ....... ,:; ~, :.,,-f ''"t' ~ ·1 -·'\" ,"J', ' ' 1, a : ' " ii IC :):}: I I ; i " ' 17-19 Ill Ill o., Cl <l'. w ().Z_ - 0 <l'. >' _J ~ 45-4 f-71 L ___ _ I 52-55 1-- __ ,,_,:-7 j ---! I ------ HARDING ·,'·''""'"'"'''"" ------:,:::\._~_i;;/4 __ -·--'\ -""----,- • --:/-:?] (" STR ET GENERAL INFORMATION BMP ID# BMP TYPE SYMBOL BMP TABLE CASQA NO. QUANTITY INSPECTION FREQUENCY MAINTENANCE FREQUENCY TREATMENT CONTROL/LOW IMPACT DESIGN (LID)/HYDROMODIFICATION FACILITIES 1-15 FLOW-THROUGH PLANTER/ BIORETENTION AREAS 16-55 ROOF DRAIN TO PLANTER 56-73 INLET WITH KRISTARFILTER SOURCE CONTROL 74-77 SITE DESIGN AND LANDSCAPE PLANNING 78 STORM DRAIN SYSTEM SIGNS ROOF DRAIN DOWNSPOUT. REFER TO PLUMBING DRAWINGS FOR EXACT LOCATIONS AND CONTINUATION WITHIN BUILDING. REVERSE BEND TRAP OR HOODED OVERFLOW WITH STRAINER AT X' O.C. COBBLES OR SPLASH BLOCK ROOF DRAIN DOWNSPOUT. REFER TO PLUMBING DRAWINGS FOR EXACT LOCATIONS AND CONTINUATION WITHIN BUILDING. REINFORCEMENT PER -1--...u1 STRUCTURAL DRAWINGS 6" MULCH FOR PRETREATMENT PLANTER WALL PER STRUCTURAL DRAWINGS 2' SANDY LOAM, MINIMUM INFILTRATION RATE 5" PER HR WATERPROOFING MEMBRANE -.,_- 12" OPEN-GRADED GRAVEL, 1/2" DIA. PER ASTM 448 N0.57 NOTE: Fe'= 2,500 PSI MIN. Fy= 60,000 PSI MIN. d • fill!Jl TC-31 SD-11 TC-50 SD-10 SD-13 PERFORATED 1115 SQ. FT. 40 EA. 17 EA. SEMI-ANNUAL SEMI-ANNUALLY VEGETATION MANAGEMENT SEMI-ANNUALLY QUARTERLY DEBRIS REMOVAL EVERY QUARTER DEBRIS REMOVAL EVERY QUARTER 11,101 SQ. FT. SEMI-ANNUALLY SEMI-ANNUAL VEGETATION MANAGEMENT 1 EA. ANNUALLY 4" OVERFLOW PIPE AT X' O.C. --TREES PER LANDSCAPE DRAWINGS • VERIFY READABILITY OF SIGNS PIP;:.E ___ _.,;'--a---,,.-__bj:::::.j X" OUTLET PIPE AT X' O.C < • ,~::::;:::::::::;;:::::::':::::::;::::::::;::::~ FOOTINGS PER STRUCTURAL DRAWINGS STORM DRAIN OUTLET PIPE TO CURB FACE LIMIT OF DISTURBANCE: 0.90 ACRES. 38.781 SQ. FT. 8 FLOW-THROUGH FILTRATION PLANTER BOX / N.T.S CONSTRUCTION SIGN OFF SWMP NO. 11 -I 'Z. MAINTENANCE AGREEMENT DOCUMENT: YES~ NO_ RECORDATIQN NO. ____ _ PARTY RESPONSIBLE FOR MAINTENANCE: NAME TAVARUA SENIOR APARTMENTS CONTACT GARY E DUBOFF ADDRESS 1640 S. SEPULVEDA BLVD LOS ANGELES, CA 90025 PHONE NO. -~(3~1~0L) ~5~75~-~3~5~43'-- PLAN PREPARED BY: NAME DAN KRIEF COMPANY KPFF CONSULTING ENGINEERS ADDRESS 6080 CENTER DRIVE LOS ANGELES, CA 90045 PHONE NO. 310-665-2800 CERTIFICATION ____ _ BMPNOTES: 1. THESE BMPS ARE MANDATORY TO BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS OR THESE PLANS. 2. NO CHANGES TO THE PROPOSED BMPS ON THIS SHEET WITHOUT PRIOR APPROVAL FROM THE CITY ENGINEER. 3. NO SUBSTITUTIONS TO THE MATERIAL OR TYPES OR PLANTING TYPES WITHOUT PRIOR APPROVAL FROM THE CITY ENGINEER. 4. NO OCCUPANCY WILL BE GRANTED UNTIL THE CITY INSPECTION STAFF HAS INSPECTED THIS PROJECT FOR APPROPRIATE BMP CONSTRUCTION AND INSTALLATION. SWMP DATA PROPOSED SITE FEATURES IMPERVIOUSNESS: ROOF: 22,740 SQ. FT.* WALKS (DISCONNECTED IMPERVIOUS AREAS): 4,007 SQ. FT.t 26,747 SQ. FT. TOTAL PERVIOUS: PLANTER/ BIORETENTION AREA: LANDSCAPE: 1, 115 SQ. li<r. 11,101 SQ. FT. 10,922 SQ. FT. TOTAL GEOTECHNICAL DATA PERCHED GROUND WATER GROUND WATER AT 12' BELOW SURFACE EXISTING SITE FEATURES IMPERVIOUSNESS : 27,233 SQ. FT. PERVIOUS 11,546 SQ. FT. EXISTING SITE FLOW 0(2 "'l = 2.23 CFS 0(10 YR) = 3.13 CFS PROPOSED SITE FLOW 0(2 YR) = 2.21 CFS Qc10 YR) = 3.10 CFS PLAN SCALE: 1" = 20' -0" 0 10' 20' 40' GRAPHIC SCALE I SH~ET I CITY OF CARLSBAD I SH~ETS I ENGINEERING DEPARTMENT ONE SHEET TREATMENT BMP: TAVARUA SENIOR APARTMENTS 3596 HARDING ST., CARLSBAD, CA APPROVED: -/ ~ GLEN K. VAN },SKI rZ/11; CITY ENGINErR PE 41204 EXPIRES 3/31/13 DATE DWN BY: PROJECT NO. DRAWING NO. CHKD BY: SOP 06-12(A) RVWD BY: 473-2SW