Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DWG 476-5L; RP 12-13; ARMY NAVY ACADEMY; 01-13
GENERAL NOTES RECYCLED WATER NOTES I. ALL WORK SHALL BE DONE IN ACCORDANCE Wl1H 1HE CARLSBAD MUNICIPAL WAJER DIS1RICT'S RULES AND REGULATIONS. 2. DRINKING WA T£R FOUNTAINS AND DE:SIGNA TE:D OUJDOOR EA TING ARE:AS SHALL BE PROT£CTE:D AGAINST CONTACT W/1H RECYCL£D WAJER SPRAY, MIST OR MISTING. 3. BEST MANAGEM£NT PRACTICES SHALL BE USED TO ELJM/NAT£ OR CONTROL TO 1HE BE:ST EXT£NT POSS/Bl.£ PONDING, RUN-OFF, OV£R-SPRA Y, AND MISTING. 4. HOS£ BIBS ARE S1RICTL Y PROHIB11ED. 5. CROSS-CONNECTIONS BETWE:EN RECYCLED WATE:R UNES AND POTABI.£ WAT£R UNES ARE S1RICTL Y PROHIB/T£D. RECYCLED CARLS BAND SIGNAGE NOTES WATER SYSTEM (PRIVATE) BLVD* AND BEECH AVENUE DRAWING INDEX: SHEET TITLE SHEET NUMBER TITLE SHEET 1 RECYCLED WATER PLAN 2 IRRIG. LEGEND & NOTES 3 /RR/GA TION PLANS 4,5 /RR/GA TION DETAILS 6,7 HYDROZONE DIAGRAMS 8,9 PLANTING LEGEND & NOTES 10 - 6. 7. 8. NO SUBSTITUTION OF PIPE MATERIALS WILL BE ALLO~D Wl11-/0UT PRIOR APPROVAL OF THE CITY OF CARLSBAD MUNICIPAL WA T£R DIS1RICT. ALL MAINLJNE PIPES SHALL HAVE WARNING TAPE PER CARLSBAD MUNICIPAL WATER DIS1RICT'S RUL£S AND REGULATIONS. HOURS FOR JRR/GA TION WITH RECYCLED WATER ARE FROM 10: 00 P.M. TO 6: 00 A.M. 1HE HOURS FOR IRRIGATION Wl11-1 DISINFEC1ED TE:RTIARY RECYCLED WAJER MAY BE MODIF1ED BY THE LOCAL AUTHORITY. IRRIGATION OUR/NG PUBUC USE PERIODS WITH DISINFECTED TERTIARY RECYCL£D WATER SHALL Bf UNDER 11-/E SUPERVISION OF 11-/E DES/GNA T£D USER SUPERVISOR. JRRJGA TION Wl1H WATER OF A LE:SSER QUAUTY THAN DISINFECTED TERTIARY RECYCLED WATER SHALL BE BETWE£N THE HOURS OF 10:00 P.M. TO 6:00 A.M. THE FOLLOWING GUIDELINES FOR THE USE OF RECYCLED WA1ER ARE TO BE PERMANENTLY POS7ED INSIDE THE DOOR OF EACH CONTROLLER WHERE 111EY ARE EASILY VISIBLE. PLACE ON 8-1 /2• X 11 • SIZED SIGN. COLOR: PURPLE BACKGROUND Wl1H BLACK LETTERING. I. GUIDELJNES FOR RECYCLED WATER USE WATER EFFICIENT LANDSCAPE DECLARATION: I AM FAM/UAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN 1HE CITY OF CARLSBAD'S LANDSCAPE MANUAL cl-WATER EFFICIENT LANDSCAPE REGULATIONS. I HA\1£ PREPARED 1HJS PLAN IN COMPUANCE Wl1H 1HOSE REGULA T/ONS AND 1HE LANDSCAPE MANUAL I CERTIFY THAT 1HE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EfflCJENT USE OF WA 1ER. BY: PLANTING PLANS PLANTING DETAILS 11, 12 13 0 N 9. BURIAL OF WIRING AND PIPING SHALL MEET CMl'IO RULES & REGULA T10NS. 10. NON-DESIGNATED USE AREAS SHALL BE PROTECTED FROM CONTACT WITH RECYCLED WATER, WHE:1HER BY WIND BLOWN SPRAY OR BY DIRECT APPLICATION 111ROUGH IRRIGATION OR OTHER USE. LACK OF PROTECTION, WHE111ER BY DESIGN, CONS1RUCT10N PRACTICE OR SYSTEM OPERATION IS S7RICTL Y PROHIBITED. 11. /RR/GA TION H£ADS SHALL BE RELOCATED OR ADJUSTED TO MINIMIZE OR ELIMJNA TE OVER- SPRA YING ON SID£WALKS, STREETS AND NON-DESJGNA TED USE AREAS. 12. RECYCLED WAJER QUICK COUPUNG VAL\IE'S SHALL BE OF A TYPE: DESIGN£D FOR 11-/E US£ ON R£CYCLED WAT£R DISTRIBUTION SYSTEMS PER CARLSBAD MUNICIPAL WAT£R DJS1RJCT'S RUL£S AND REGULA T/ONS. 13. ON RECYCLED WATER SYSTEMS. ALL APPURTENANCES (SPRINKL£R H£ADS. VAL\1£ BOXES, ETC.) SHALL BE COLOR-CODED PURPLE P£R AWWA GUJD£UNES AND SECTION 116815 OF THE CAUFORNIA HEAL TH AND SAFETY CODE. 14. ALL IRRIGATION PIPE SHALL 8£ ST£NCIL£D WITH WARNING, "NON-POTABLE OR R£CYCLED WATER•, COLOR-CODED (PURPLE) AND LAID WIT/-/ WARNING TAP£ AND STENCIUNG ORJENT£D TOWARD THE TOP OF THE TR£NCH PER THE CARLSBAD MUNICIPAL WAT£R DISTRICT'S RUL£5 AND REGULA T/ONS. 15. ON NEW ON-SITE SYSTEMS (POST-MET£R), POTABLE WATER, CONSTANT PRESSURE RECYCLED WATER AND SEWER UNES SHOULD BE PLACED A MINIMUM OF FOUR FEET APART OR AS DIRECTED BY 111E PROJECT ENGINE£R AND/OR REGULATORY AGENCY. MEASUR£MENTS SHALL BE 8ETWE:£N FACING SURFACES. NOT PIPE CENTERUNES. 16. CONSTANT PRESSURE RECYCLED WAT£R UNES SHALL CROSS AT LEAST TWE:L\1£ INCHES BELOW POTABLE WA1ER UNES AND MAINTAIN AT LEAST TWE:L\1£ INCHES CROSSING SEPARA 110N BETWE:EN OTHER UT/UT/ES. 17. IF A CONSTANT PRESSURE RECYCLED WATER UNE MUST BE INSTALL£D AB0\1£ A POTABLE WAT£R UNE OR LESS THAN l11£L\IE INCHES BELOW A POTABLE WATER UNE, TH£N THE RECYCLED WATER UNE SHALL BE INSTALLED WITHIN AN APPROVE:D PROJECTIVE: SL££\,£ AS PER 1HE CARLSBAO MUNICIPAL WA T£R DISTRICT'S RULES AND RE:GULA T/ONS, 18. THE REQUIRED CROSS-CONNECTION SHUTDOWN JEST SHALL BE DONE BY 111E CARLSBAD MUNICIPAL WA1ER DISTRICT AND 1HE SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH. 19. THE REQUIRED CROSS-CONNECT/ON INSPECTION SHALL BE DONE BY EITHER 111E CARLSBAD MUNICIPAL WATER DIS1RJCT ANO/OR THE SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH. COPIES OF INSPECT/ON REPORTS WILL BE FORWARDED TO THE NON-INSPECTING PARTY. 20. 11-/E DESIGN AND LOCATIONS PROPOSED FOR RECYCLED WA 1ER "DO NOT DRINK" SIGN SHALL BE CALLED OUT ON THE PLANS. 21. WHEN RECYCLED WAT£R BECOMES AVAJLABI.£, AN ON-SJ1E USER SUPERVISOR SHALL BE DESIGNATED IN WRITING. 1H/S INDIVIDUAL SHALL BE FAM/UAR WITH PLUMBING SYSTEM Wl1H/N 1HE PROPERTY. Wl1H 1HE BASIC CONCEPTS OF BACKFI.OW/CROSS-CONNECT/ON PROT£CTION, 111E RECYCLED PUREYOR'S RULES ANO REGULATIONS AND 1HE SPEC/RC REQUIREMENTS OF A RECYCLED WA1ER SYS1EM. COPIES OF 111E DESIGNATION, Wl1H CONTACT PHONE NUMB£RS SHALL BE PROVIDED TO THE CARLSBAD MUNICIPAL WAT£R DIS1RICT. IN CASE OF EMERGENCY CONTACT OR AFJER HOURS CONTACT MIL£S WARNER AT 760.547.5244 OPERATIONS OFFICE AT 760.547.5227 22. ALL PUBLIC AND PRIVATE POTABLE WATER MAINS INCLUDING flRE MAINS AND ANY WA 1ER ~LLS AND WA 1ER COURSES Wl1H/N THE RECYCLED WA 1ER PROJECT SHALL BE SHOWN ON THE PLANS. 23. CALL OUT ON 1HE PLANS IF 1HERE ARE OR ARE NOT DRINKING FOUNTAINS AND/OR DES/GNA1ED OUJDOOR EATING AREAS ON THE SITT::. 24. A PHYSICAL SEPARA T/ON SHALL BE PROVIDED BE"/WE:EN ADJACENT AREAS /RR/GA 1ED Wl111 RECYCL£D WAJER AND POTABLE WAJER. SEPARATION SHALL BE PROVIDED BY DISTANCE, CONCRE1E MOW STR/ PS OR OTHER APPROVED ME1HODS. 25. ALL IRRIGATION BACKFI.OW PRE\1£NT£RS SHALL BE TEST£D BY A CERTIFIED T£STER AND RESULTS MUST BE Gl\1£N TO 1HE CITY AND THE CARLSBAD MUNICIPAL WATER DIS1R/CT. PIPE BETWE:EN THE METER AND BACKFI.OW PRE\1£NTER SHALL BE "SCHEDULE K HARD COPPER". APPROVED CONTRACT BACKFI.OW TESTERS CAN BE FOUND ON THE CITY ~B SIT£ AT http: //www.carlsbadca.gov/services/departments/water/Documents/ recycledwaterbockflowtesterlist.pdf for recycled or http: //www.carfsbadca.gov/services/ departments/woter/Documents/woterbockflowtesterlist.pdf for potable or call 438-2722. PURPLE BACKROUND r-1" BLACK LETTERS A. B. C. D. E. F. G. IRRIGATE BETWE:EN THE HOURS OF 10:00 P.M. AND 6:00 A.M. ONLY. WATERING OUTSIDE THIS TIME FRAME MUST BE DONE MANUALLY Wl1H QUAUFIED SUPERVISORY PERSONNEL ON-SIT£. NO SYSTEM SHALL AT ANY TIME BE LEFT UNA T1ENDED DURING US£ OUTSIDE THE NORMAL SCHEDULE. /RR/GA TE IN A MANNER THAT WILL MINIMIZE RUN-OFF, POOLING, AND PONDING. 1HE APPUCA"nON RA 1E SHALL NOT EXCEED Tl-IE INF1L 1RA TION RA 1E OF 111E SOIL TIMERS MUST BE ADJUS1ED SO AS TO BE COMPATIBLE WITH THE LOM"ST SOIL INFIL 7RA T/ON RA TE PRESENT. 111JS PROCEDURE MAY BE FACIUTA T£D BY IHI:. EFFJCIENT SCHEDULING OF 111E AUTOMATIC CONTROL CLOCKS, (I.E., EMPLOYING 111E REPEAT FUNCTION TO BREAK UP THE TOTAL IRRIGATION TIME INTO CYCLES 111A T WILL PROM01E MAXIMUM SOIL ABSORPTION). ADJUST SPRAY HEADS TO ELIMINATE OVERSPRAY ONTO AREAS NOT UNDER THE CON7ROL OF THE: CUSTOMER. FOR EXAMPLE, POOL DECKS, PRIVATE PATIOS AND LOTS, AND STREETS AND SIDEWALKS. MONITOR AND MAINTAIN THE SY.STEM TO MINIMIZE EQUIPMENT AND MA 1ER/AL FAILURE. BROKEN SPRINKLER HEADS. LEAKS, UNRELIABLE VALV£S, ETC., SHOULD BE RE:PAIRED AS SOON AS THEY BECOME APPARENT. THE LANDSCAPE CONTRACTOR JS RESPONSIBLE FOR EDUCATING EACH EMPLOYEE AND ALL MAINJENANCE PERSONNEL ON A CONTINUOUS BASIS. REGARDING 1HE PRESENCE OF RECYCLED WATER. MAIN1ENANCE P£RSONNEL MUST BE INFORMED 111A T WA 1ER IS FOR JRRIGA T/ON PURPOSES ONLY AND IS NOT APPR0\1£0 FOR DRINKING OR FOR HAND AND TOOL WASHING, ETC. OBTAIN PRIOR APPROVAL OF ALL PROPOSED CHANGES AND MOD/FICA T10NS TO ANY PRIVATE: ON-SITE: FACILITIES. SUCH CHANGES MUST BE SUBMITTED TO, AND APPROVE:D BY, THE DIS1RICT ENGINEERING OFFICE AND DESIGNED IN ACCORDANCE Wl1H DISTRICT STANDARDS. 1. ALL RECYCLED WAT£R SPRINKLER CONTROL VAL\1£S SHALL BE TAGGED WITH JDENTIF1CA TIO/II TAGS. 2. A. TAGS SHALL 8£ WEATHERPROOF PLASTIC, 3•x 4-'; PURPLE IN COLO~ Wl1H THE KORDS "WARNING RECYCLED WATER -DO NOT DRINK IMPRINTED ON ONE SIDE, AND "AVISO -AGUA /MPURA-NO TOMAR• IMPR/N1EO ON THE 01H£R SIDE. IMPRINTING SHALL BE PERMANENT AND BLACK IN COLOR. USE TAGS AS MANUFACTURED BY T. CHRISTY ENTERPRISES OR APPROVED EQUAL 8. ONE TAG SHALL BE ATTACHED TO EACH VAL\1£ AS FOLLO~: I. ATTACH TO VALVE ST£M DIRECTLY OR WITH PLASTIC TIE-WRAe.._OR 2. ATTACH TO SOLENOID WIRE DIRECTLY OR WITH PLASTIC TIE-WRAP .QB. 3. ATTACH TO VAL\1£ C0\1£R WITH EXISTING VAL\1£ COVf:R BOLT. ALL SPRINKL£R HEADS SHALL BE IDENT1f1EO AS RECYCLED WATER SPRINKLER HEADS. EACH AUTOMATIC CONTROLL£R AND ITS ASSOCJAT£0 EQUIPMENT SHALL BE IDENTIFIED W/111 A SIGN BEARING THE WORDS "RE;CYC[.ED WA TE;R USE;D FOR IRRIGAllQN• IN ENGUSH AND SPANISH, WITH BLACK LETTERS 1• HIGH ON A PURPLE BACKROUND. THE SIGN SHALL BE PLACED SO 111A T IT CAN BE READILY SEEN BY ANY OPERATIONS PERSONNEL UTILIZING 1HE EQUIPMENT. I HEREBY DECLARE 1HA T I AM OF WORK FOR 11-1/S PROJECT, THAT I HA \1£ EXERCISED RESPONSIBLE CHARGE OVER 1HE D GN OF 11-1/S PROJECT AS DE:FINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE AND 111AT 1HE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDE:RSTAND THAT 7HE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD AND SAN DIEGO COUNTY DEPAR1::tGJ!)fliJJ,/f;fs is CONF1NED TO A REVIEW ONLY AND DOES NOT REL/EV£ ME:, AS Z OF WORK, OF MY RESPONSIBILJTIES FOR PROJECT DESIGN. flRM NAME & ADDRESS: PHONE NO: (Sz_~ .. ,cy REGISTRATION NO:_ 1 EXP/RAT/ON DA TE:: /z. --1/• /3 r BLACK LOGO 36.. / In Order to Conserve Water ... DI RT ~9Suio. (N.T.S.) ~ RECYCLED WATER IN USE WARNING RECYCLED WATER DO NOT DRINK ~ f DO NOT ~ DRINK NO TOME EL AGUA DIAL TOLL FREE 1-800-422-4133 AT I..EASJ 1WO DA'!$ BEFORE YOU DIO UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA LANDSCAP.1! ARCHlTECTURll l 1688 E. South Street, Suite 201 Artesia, California, 90701 PHONE: (562\ 860-1021 CA. LlC. NO. Ul1l I AZ, UC. NO. 889.2 FAX:: (562) 860-1091 NV.LIC.N0.78 Email: kohataaseoc@verlmn.net PHONE NO: 1'9~ REG/S1RA TION NO: INSPECTION PROCEDURES 1. 2. 3. 4. DISTRICT CONSTRUCTION INSPECTION SHALL INCLUDE: A. REQUIRE:D SEPARATION BETWE:EN POTABLE ANO RECYCLED WA1ER UNES (HORIZONTALLY AND \1£RT1CALL Y). B. PIPE JDENT/FICA T/0/11. C. SLEEVING AT CROSSINGS. D. APPROPRIA 1E MATERIALS AND MARKINGS, INCLUDING PROP£R QUICK COUPLERS. AN APPROVAL LETJER REGARDING 1HE INSPECTION OF 1HE PROJECT SHALL BE OBTAINED FROM THE CITY AND THE DJS1RICT, AND BE FORWARDED TO THE COUNTY H£ALTH DE:PARTMENT PRIOR TO FINAL INSPECTION APPROVAL D/S7RICT f1NAL INSPECTION SHALL INCLUDE: A. SJGNAGE INSTALLED PER PLAN. B. CONTROLLER ST/CK£RS. C. TAGGING OF VAL \1£S. D. C0\1£RAGE T£ST AFTER COMPLETION OF THE SPRINKLER SYSTEM TO ENSURE PROTECTION OF AREA NOT APPR0\1£D FOR RECYCLED WA1ER USE. E. ALL ASPECTS OF 1HE /RR/GA TION CONDITIONS INCLUDING WINDBLOWN SPRAY. RUNOFF, AND PONDING. F. REQUJRE:D PROT£CTION OF ALL RESIDENTIAL AREAS. G. REQUIRED PROT£C110N OF WE:LLS. STREAMS. RESERVOIRS. ETC. H. CROSS-CONNE:CTION JEST IF REQUIRED. /. COLOR CODED, LAMINA 1ED CHARTS INSIDE EACH CONTROLLER. ANNUAL INSPECTION SHALL INCLUDE: A COMPLE1E INSPECTION THAT WILL COVE:R A-I OF THE DISTRICT FINAL INSPECTION. REVISIONS MUST BE APPR0\1£D BY PUBLIC HEALT/-1 ENG/NEE:R, CITY ENGINEER AND DIS1R/CT ENGINEER PRIOR TO /MPLEMENTA T/ON IN fJEI.D, LANDSCAPE CONSTRUCTION INSPECTIONS: INSPECTION OF THE PROJECT SHALL BE PREFORMED BY THE LANDSCAPE ARCHITECT OF THE WORK, OR HIS DESIGNATED AGENT. REFER TO THE SPECIFICATIONS FOR THE SCHEDULE OF REQUIRED INSPECTIONS AND SUBMITTALS. FOLLOWING COMPLETION OF lHE WORK, THE LANDSCAPE ARCHITECT OF WORK WILL CERTIFY THAT THE INSTALLATION HAS BEEN COMPLETED BY SUBMIT11NG THE "FINAL LANDSCAPE CERTIFlCA TION FORM". A REQUEST FOR A FINAL LANDSCAPE INSPECTION BY THE CITY MUST ALSO BE MADE BY CALLING THE INSPECTION REQUEST LINE. "FINAL LANDSCAPE CERTIFICATION FORM" FAX TO: 760-944-8943 LANDSCAPE INSPECTION REQUEST PHONE LINE: 760-602-4602 ARMY/NAVY SITE en REDUCED KEY MAP CITY OF OCEANSIDE :>, PACIFIC OCEAN (1 ~-~~ ~,...... : CITY or VISTA ~• ROA CITY OF ENCINITAS VICINITY MAP APPROVED FOR IRRIGATION AND PLANTING ONLY. INCLUDING PRECiSE LOCATION OF PLANTING AREA COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEALTH LAND AND WATER QUALITY Dlv1S10N GLENN LEEKS ENVIRONMENTAL HEAL TH SPECIALIST "AS BUil T" TITLE REVIEWED BY: INSPECTOR s--1-13 DATE DATE DATE CARLSBAD MUNICIPAL WATER DISTRICT SHEET 1 CITY OF CARLSBAD PLANNING DIVISION 13 SHEETS --------+---+----+------1---< PRIVATE (ONSITE) RECYCLED f------1--+-----------------+---+-------+---+------I WATER SYSTEM FOR: VI SH HANDS AFTER CONTACTING LAVESE US MANOS DESPUES DE USAR WASH HANDS AFTER CONTACTING LAVESE SUS MANOS DESPUES DE USAR CARLSBAD MUNICIPAL WATER DISTRICT DEVELOPERS NAME: ___________ _ ARMY AND NAVY ACADEMY TITLESHEET 12" X 36" SIZE .032 ALUMINUM, .060 ABS PLASTIC OR STICK-ON VINYL SIGNS 1" BLACK LETTERS 2" BLACK LETTERS TYPICAL SIGNS C: DRAWING FILES TITLE SHEETS RECYCLED WATER TilLE SHEET.DWG 5 15 2012 18" X 18" SIZE .032 ALUMINUM, .060 ABS PLASTIC OR STiCK-ON VINYL SIGNS E)(plrotion Dote: CARLSBAD BLVD. AND BEECH AVENUE ADDRESS: f-------1--+----------------t---+-----t---+------IAPPROVED /_,J/// , ~ ~ f------1--+-----------------+---+-------+---+------I PLANNING ..,M~ t~ I) !0/3 ,__ ________ T_E_L_EP_H_O_N_E:_-_-_---~----_-_-_-_-_-_ -~~+--~-+-----~ --------+--------+--+------1-----,DRWN BY, PROJECT NO. WILLIAM[: PLUMMER /AT/ DA TE PLAN PREPARED: DA TE INITIAL R EVI SI ON DE SCRI p Tl ON e---::D:..:.A TEc::......J...:::IN:._::ITl_:AL=-+_:D::.:ATE.:::_...L::.IN::.:IT::.:IA::_L -tcccHoecK"-D"B"Y,------1 RP-12-13 DEPUTY CITY ENGINEER R.C.E.28176 EXP. ~I 20Jl.f BY: ENGINEER OF WORK -OTHER APPRDVAL CITY APPROVAL DRAWING NO. 476-SL TI..E SHE TS LS -IP. WG J \ \ r'.'._ ~- _ • .,.~ -. ' "-l '--..__ LEGEND -w- POTABLE WATER METER RECYCLED WA '/ER ME1ER BACKFLOW PREVENTION DEVICE INSTALL PER CMWD POTABLE WATER LINE -RW-RECYCLED WATER LINE -RC-~~ff~bffr ~t'f!i,~ y LIN£ -FS-FIRE SERVICE LINE ~ t:,, - RECYCLED WA '/ER USE AREA DO NOT DRINK SIGN ~ UTDOOR EA TING AREA PROTECTED AGAINST CON- ACT WITH RECYCLED WATER) 2 12 j_ POTABLE WATER BACKFLOW NOTE DO NOT DRINK SIGNAGE SHALL BE INSTALLED AT TIME OF TRANSITION FROM DOMESTIC TO RECYCLED WA '/ER. CURRENTLY THIS PROJECT IS NOT CONNECTED TO A NON-POTABLE WATER SOURCE, J 'i i 1,' I POTABLE WATER HOSE BIB FOR FIELD .. L . . --...___ POTABl,'E WA 7E'R HOSE BIB FOR FIELD ' .' I • "· •• -·-cc i.', V i /• ~OTABlE WATER HQSE Blf/ FO~ hELD-"--~ :! ' ! ' POTABLI: WATER HOSE BIB FOR FIELD ;\-::-··,. '·') .~>) .!2\k:: :•·-:-';: l{ffr~ .,,,-. ''' A):1/::tf .5';;,\ (<.,t .,, ~\~_,,, ••,,/,'~' I :":;_' ';-:: ,: ,< _"-. ', ,.,: ,' ·-, "'\ '; ,',v > ..C., 'f' ' ' ' , . ,,,. , ' -!',-., ' l-,,~-!;::' ,!-• -' ' ' ✓ , -;, ,'. , , '-" ;,-,, ;~:,~·';1/ ,-;_:(:../:'·}fr,',' ! ,: -; 't..-' '/._.'s •' f~•~• V ,v•, ,-'"J ~ ,,~,., J',".""';,_"-.,'"'',•? ,~-, ,' , -;} -. ., ,. {. ~ ,,_ ,._~ ,.•, ~· ,! ,. : j. ' ' - POTABLE WATER HOSE BIB FDR FIELD'" ';'.,,-<-, .,, ~~ ' ~ )< • -, l~~" ~? ' ' ,I-:-;~ C > I • "'? .4::,~•--.{\ A-.;.::ic ,:t-"fl-' ,, -·,~---'r ~ :.~:~~-t?_·:; . . . ,·,:-•,.·;·•c ;> /£.,-, "'7 ' _',_:;~?>;: -~(!:.: ,·',.-·:"-,-/ ,:_· ,_,,t/_ ..,~ ---.;i<. : _,--c-,--;;;;p_: -•:: ---,--<' -~~--~:?~:--? __ :_:_:-~~~-~~"~-u~-~=-::~~~·-~~c~·:,-:y -=·~~---~-~--~. ·:-:C:·:--=-=:;:--~-J---.. :., •~.-_•_': .. -,,.,, .-~,-,, ··~·•~..::..:.;,;~ ' ---... -----~-:""_"":":·----· f>QTABLE WATER BACKFLOW ·-----.., -POTABLE-WATER _METER ---... ~ ------·-v--- .< ·~ ---..,_ -' " ·O · --- /' - I;' '' J ' : I I I J Q:i i ' j I "' I I I "' I I I . -·---<-;:~·r- I ~\:t _)', \i rlJ '.o ,, : ,, 30 15 NORTI-! Scale, 0 I" = 30' 30 SCALE IN FEET 60 APPROVED FOR !RR/GA TION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. "AS BUILT" RCE __ _ EXP ____ _ DATE REVIEWED BY: INSPECTOR DATE 1------1---1--------------+--+--+--+----t I SH2EET I CITY OF CARLSBAD ~3 PLANNING DIVISION l_lU ~L=A~N;:DS;:C;:A~P;;E=;:IMP;:;R;;O~VE~M~E;;NT~~P:;::LAN~S~F;,:0;:R:==='..':::==~ OSC4 ,._f.0&117: ~ r ' ·~~~ OF e-.t.~ LANDSCAPE AROm1lCTURB 11688 E. South-~ Suite 201 Artesia, Cali:fomia, 90701 PHONE: (562) 860-1021 CA.UC.l'l'D. l219 l,Z. LIC. l'fO. 8892 FAX: (562)8tS0-1091 NV.UC.R0.18 £moll: kDbalaa8~ DATE INITIAL DESIGNER OF WORK REVISION DESCRIPTION DATE INtllAL DATE INITIAL OTHER APPROVAL CITY APPROVAL ARMY / NAVY ACADEMY RECYCLED WATER AREA USE MAP CARLSBAD BLVD. AND BEECH AVENUE I APPROVED: PLANNING DWN BY: CHKD BY: _,R~L.,.,__ RVWD BY: RKK PROJECT NO, DRAWING NO. RP 12-13 476-5L GENERAL IRRIGATION NOTES A6-1SS1: WATER 6UDGET l~IG:ATION LEG:END I. ALL MAINLINE, LATERAL FIFING AND CONTROL WIRE6 UNDER PAVING 61-lALL BE INSTALLED IN 6EFARATE 6LEEVE6. IMPORT ANT NOTE FORMULA WATER METER No.I CONTROLLER I A I MAIN LINE AND LATERAL LINE 6LEEVE6 6f-!ALL BE A MINIMUM OF 1UJICE 12X) Tl--!E DIAMETER OF TI--IE FIFE TO BE 5'lttl0!. NAH.F~ NO. f'el RAD. QJAR!fR llALF PJLL DETAI~ SLEEvED. CONTROL WIRE SLEEVING $!-!ALL BE OF SUFFICIENT SIZE FOR Tl-IE REQUIRED NLN6ER OR WIRE$ UNDER CONTRACTOR 51-lALL PROTECT IN PLACE EXISTING IRRIGATION 5.,.-5TEM AND MAXIMUM AFFLIED WATER ALLOWANCE QIR llALF PJLL Pl<ECI". P!<ECIP. f'RECIP. f'!EF. NO. PAVED AREAS. SLEEVES 6f-!ALL BE SCI-I 00 AND INSTALLED FER MINIMUM FIFE COVERAG.E 4 MINlr-1JM SLEEVE MAINTAIN FULL.,.-OPERATIONAL DURING T!-lE CONSTRUCTION Pl-lA5E. @ l<ll!l-a-C-14<!2 &ERIE$ n;£E DEEP ROOT f):,0 l!ll!. 1 COVERA::il: NOTE T!-IIS 6f-!EET. MAWA = (ETo)(0.7)(LAX0.02) RA!eli<D lllA1ERll't, 5'\'51EN (2 llUBBLER5 PER TREE! 3R) l' Ob') N0.8 2. FIFE SIZES $!-!ALL CONFoi.l-1 TO Ti-!06E SI-IOUJN ON TI--IE DRAWINGS. NO SUBSTITUTIONS OF SMALLER SIZES WILL BE CONTRACTOR 51-lALL RESTORE IRRIGATION e,.,.-5TEM5 AND REINSTALL IF < 40.0)(0.7)(20,<~!=>3X0.02) = 4~7,9(2)4 RB. f'R!:eeuRE COMFEN5ATING 110DUL£ FC-tl5-~l 3R) )' 11):,0 l!ll!. 1 PERMITTED, 6UT SUBSTITUTIONS OF LAl<!::IER 6IZES MAY 6E APPROVED. ALL DAMAGED AND REJECTED FIFE 6f-!ALL AFFECTED 6.,.-CONSTRUCTION TO ITS ORIGINAL DESIGN INTENT. RB. DT-0.lS V4' YINYL D~TRleuTIOM 1ll8II<; Gf'l4 NO. 6, 1 BE REMOVED FROM THE 5ITE AT Tl-IE TIME OF &AID REJECTION. (MAWA) EB RA!ell<D RB. 1&-0.lS IM',,_ 6TAKE ~ PC-"5-!re2 EMrrTER RB. 5E6.f,X S!JB-EMmER BOX 3. FINAL LOCATION OF THE AUTOMATIC CONTROLLER 6HALL BE AFFROVED BY CLIENT'S AUT!-IORIZED REFRESENTATlvE. 6A5ED ON ON-SITE CONDITIONS, CONTRACTOR 51-lALL INSTALL NEW RB. XEi.1-BIRD~ l1L TI-GIJTLET EMI5SIOM DEv!CE FER51Re,Lk;IIT- 4. IRRIGATION CONTRACTOR SI-IALL COORDINATE AND PROVIDE ELECTRICAL FOlLER TO CONTROLLER IT 16 TI--IE IRRIGATION WIRE5 AND/OR REDIRECT WIRES A5 REQUIRED PER EXISTING ESTIMATED TOTAL WATER USAGE RB. FC-Dlf-PPL DIRal5cR CAP RE5FON51BILITY OF Tl-IE IRRIGATION CONTRACTOR TO COORDINATE ELECTRICAL SERVICE WIT!-1 Tl-IE $CE FLANNER AND PROPOSED IRRIGATION LAYOUT. CONTRACTOR 51-lALL CONTACT + SLA) 83 SAi.CO F5T-2 FIIO&Fi:C EMITTERS OM IS I' I EMITTEI< 2f) l!ll!. 1 AND PRIME CONTRACTOR TO MAKE Tl-IE FINAL CONNECTION FROM ELECTRICAL 6ERVICE TO Tl-IE FREE STANDING LAND5CAPE ARCl-l!TECT IF 5ITE CONDITION5 DO NOT REFLECT (-FF X HA PVC-Ii-~ In' FLEX R~ PER51Rle GPl4 NO.) SERVICE CABINET. IRRluATION CONTRACTOR 16 RESFON6IBLE FOR ALL PERMIT, INSPECTION, AND SCE DE61uN FEES. CON5TRUCTION DRAWING IRRIGATION DE51C:iN INTENT. ETWU = (ETo)(0.02) I EMITTER "-~ l!ll!. 1 E----:3 ~~-~ RA!ell<D l4'D CIN-•Slll,FACE Di.JPLtE )d'[)~-~-M 3R) ~· IE ----F1aR ~· CsPl4 N0.112l, II !:>. ALL SPRINKLER 1-!EADS S14ALL 6E &ET PERPENDICULAR TO FINI51-1 a.RADE UNLE56 OTI-IERIIIISE 5FECIFIED. ALL PLANTED AREAS ARE TO 1-lAVE 1€>e>% IRRIGATION COVERAC:iE. ALL ._ 'v ---'l0-~~-PR5411)-CV-R (~) IZ>.16 032 l!ll!. 1 &. FLU6l-l AND ADJUST ALL SPRINKLER HEADS AND VALvES FOR OPTIMUM COVERAGE WIT!-1 MINIMAL OvERSPRAY ONTO 3R) 8' EXI5TING: NON-RJNCTIONING EQUIPMENT 15 TO REPLACED TO ALLOW FOR 5IRJ6 F'OP•lf' MP FiOTATOR NOmE IEtlP ,Z,.511) ,1):,0 NO.I WALK$, STREETS, WALLS, ETC. Tl-IE CONTRACTOR 51-!ALL USE RAIN6IRD 'PCS' FRE5SURE COMPENSATING SCREEN, 100% COVERAGE. (-0.4 X 22072--) 291,938 I,; • --'J0-~ij-PR5411).ey.,1 (~P ! l!>.16 032 l!ll!. 1 SELECTING TI--IE BE5T DEGREE OF ARC TO FIT TI-IE EXI5TING SITE CONDITIONS AND TO T!-IROTTLE Tl-IE FLOW ( 40.0)(0.02) ' = V -5I-RJ6 F'OP-lf' MP FiOTATOR NOZZLE H:AO 3R) 112)' 11).511) 1'1:,0 NO.I CONTROL AT EAC!-1 VALVE TO OBTAIN TI--IE OPTIMUM OPERATING FRE56URE FOR EACH SY5TEM. 0.7$ <ETWU) /.,. m0011J-~-l'l<05-12-l'RS40-CV-R ~P! 11>.16 032 l!ll!. 1 CONTRACTOR TO REPLACE AND REPAIR TO IT5 ORIC:ilNAL CONDITION, ANY V -3R) ~· 1. IT 15 Tl-IE RE5FONSIBILITY OF Tl-IE IRRIGATION CONTRACTOR TO FAMILIARIZE HIM6ELF WIT!-1 Tl-IE EXISTING SITE EXISTING LAND5CAPE, IRRIC:iATION 5.,.-e,TEM, UTILITIES, AND STRUCTURES SfRlB F'OP-lf' MP FiOTATOR NOZZLE I-IEAO 0.511) f):,0 NO.I CONDITIONS. TI--IE IRRIGATION CONTRACTOR 61-lALL REPAIR Ol'i: REPLACE ALL ITEMS DAMAGED BY HIS WORK AT MPLC5S5/l"f'56S3R>.f'l105•ll•F'R5411)•CV·R~AP 4~4' nA 51/t. 1 W!-llC!-l 1-lAVE 6EEN DAMAGED 6.,.-CONTRACTOR'$ WORK. CONTRACTOR 51-!ALL ~ [I IIINTER ,i, 4'X,1&' n1'.l 038 ~ NO C05T TO Tl-IE CITY. (-0.0 X 4 43$--) -F'OP·lf' MP FiOTATOR NOZZLE H:AO NO.I ASSUME FULL RESPONSl6ILITY FOR T!-lE COST TO REPAIR OR REPLACE SAID ( 40.0)( 0.02) I = Sl,99(2) OJ 0 [I] MP211)11)11)-.f'l<05-~---CV-R ~) 1'33 063 121 51/t. 1 DAMAGED ITEMS. MODIFICATIONS A5 DIRECTED 6.,.-T!-lE CITY 51-lALL 6E -3R) 18' e. DO NOT WILLFULLY IN5TALL Tl-IE 5FRINKLER 5Y5TEM AS 6I-IOU,N ON TI--IE DRAWINGS IIII-IEN IT IS 0BVIOU5 IN Tl-IE 0.7$ <ETWU) 81-R!! POP-UP HP FiOTATOR NOZZLE H:AO 0.4S 0.4S 0.4~ NO.I FIELD THAT UNKNOWN 06STRUCTIONS, GRADE DIFFERENCES OR Dl!=FERENCES IN Tl-IE AREA DIMENSIONS EXIST PROVIDED 6.,.-Tl-IE CONTRACTOR AT NO ADDITIONAL C05T TO T!-lE CITY. [Ml APA,O'A:D NEW 2' IIIA1ER ME1ER FER CML OOIEER'5 R.AN l!ll!. , Tl4AT MluHT NOT 14AVE BEEN CONSIDERED DURING ENulNEERING. SUCl-l 065TRUCTION5 OR DIFFERENCES 5HOLILD 'Aai.Jf'r IN FIELD N0.3,4 BE BROUC:il4T TO Tl-IE ATTENTION OF THE CITY ENGINEER IN T14E EVENT Tl-l!S NOTIFICATION 15 NOT PERFORMED, CONTRACTOR 51-lALL GUARANTEE Tl-IE SURVIVAL OF ALL LANDSCAPE PLANT (-0.8 X 440 --) [I] FBlCO l' el&YA ~ 1'RE!elR eACl\!'1.CW F'RE'Y91TER l1!Tl-ltl l!ll!. 6 TI--IE IRRIGATION CONTRACTOR 51-!ALL ASSUME FULL RESPONSIBILITY FOR ANY REVISIONS NECE56ARY AT NO COST MATERIAL, T!-ll5 INCLUDE5 ALL AREA5 W!-lERE DAMAC:iE !-lA5 OCCURRED DUE ( 40.0)(0.02) = 11,S(Z)S GUARDSH,IQ< VANDAL PRXlF GUARD SHACK ENCLoeu;E <;&-2 NO./ TO Tl-IE CITY. TO CONSTRUCTION OF NEW IRRIC:iATION e,.,.-5TEM AND ITS 5URROUNDING 0.7$ <ETWU) B IIILK1)(5 &10 &Ei.JE5 . AREAS. MODIFICATIONS A5 DIRECTED 6.,.-Tl-IE CITY TO REPLACE F!l£561Ra l'IE6UI.ATOR (Ln-JE SIZE FR:t1111A1ER t1£TER! . ~-ALL 5PRINKLER EQUIPMENT NOT OTl--!Ef<IIJl6E DETAILED OR 5FECIFIED 6f-!ALL 6E INSTALLED AS FER DAMAGED PLANT MATERIAL 51-lALL 6E RPOVIDED 6.,.-T!-lE CONTRACTOR ~ l23R> iiERIE& l!ll!. 6 MANUFACTURER'S RECOMMENDATION& AND $FECIFICATION$. Gf!jSIIIOI.D MASTER YAL',1: 1"1E SIZE FR:t1 lllATa. 11:TER> N0,4 AT NO ADDITIONAL COST TO T!-lE CLIENT. CONTRACTOR 51-!ALL A55UME FULL TOTAL ETWU 391,733 CliEATl'Aa I~·21/l.P -& l!ll!. 6 IIZI. REFER TO SPECIFICATIONS FOR INSTALLATION AND MATERIAL REQUIREMENT INFORMATION. RE5PON5I6ILIT.,.-FOR T!-lE COST TO REPLACE DAMAGED PLANT MATERIAL. = [JJ Sl:NSOR <ETWU) TECHNOLOOY FI.Cllll 5EN50R (SIZE I-Ill'! ~1ED N SC1-l 811) PYC TEE WI SOCKET END6 N0.3 II. CHECK VALVE$ SHALL BE INSTALLED A5 REQUIRED TO PREVENT ALL LOIII I-IEAD DRAINAuE. PRIOR TO ~ RAIN11'151ER RAIN MA61ER EAGLE PLUS WI !CENTRAL &A6·RM2-48IR'ls/G11'5-IS0PIRSE l!ll!. 6 IN6TALLATION, TI--IE CONTRACTOR 51-lALL VERIFY Tl-IE ONSITE a.RADES. IF THERE 15 AN ELEVATION DIFFERENCE OF -48 &TATIOM CONOOI.I.ER 1111 RAIN eeH&0R. 1RAN5MIT1ER I l<ECEl'Aal<. AND ENCl.oeu.E NO. I 24' OR MORE BETWEEN Tl-IE I-IIGI-IEST !-IEAD AND LOWEST 1--!EAD ON A SYSTEM, THE vALvES SHALL BE IN5TALLED. 1-lYDROZONE 1 = 22,072 SQ.FT. EB RAIN:IIRD F'E&a-R l!ll!. 6 NOTE 1'0TARl' REMOIE CCINlROL VAl.\<f (61Z£ AS INDICA1EDJ NO. If> 12. T14I5 DESluN 15 DIAGRAMMATIC. ALL FIFING, VALVES, ETC, 61-iOJN WIT14IN PAVED AREA& 15 FOR DESIGN HYDROZONE 2 = 4,43!=> SQ.FT. s XCZ·F'R5·llil>·COM l!ll!.' CLARIFICATION ONLY AND SHALL BE INSTALLED IN PLANTING AREAS ~REYER F0651BLE. Tl-IE CONTRACTOR FRIOR TO OCCUPANC.,.-AND/OR SECURITY RELEASE T!-lE LANDSCAPE ARCHITECT RA!eRl XEi.l·Bll'V Dfi1IP REl"01E ~ VAi. ',l; (51ZE AS t-lDICATED! NO., SHALL LOCATE ALL MAINLINE AND VALVE& OUTSIDE OF THE RIGHT-OF-WAY. OF WORK 51-lALL REVIEW/INSPECT Tl-IE FROJECT AND PROVIDE A CERTIFICATION EXISTING TURF = 440 SQFT. ~ RAIN:lli<D XCZ-f'R5-llil>·COM l!ll!. 6 13. Tl-IE CONTRACTOR 61-!ALL vERIFY Tl-IE STATIC FRE56URE TO 6E A5 5TATED ON Tl-IE SYSTEM REQUIREMENTS. LETTER FOR RELEASE OF SECURITIES, AND AN IRRIGATION SCHEDULE AND &ALCO 5Y51EN Dfi1IP REMOIE CCIN'll,OL YAl.',l: (SIZE AS INDICA1ED! N0.9 SHOULD THE 5TATIC FRE65URE EXCEED 20% OF Tl-IE DE516N FRE56URE, IN5TALL A 'UJILKENS' 600 5ERIE5 LANDSCAPE AND IRRIC:iATION MAINTENANCE 5CI-IEDULE A5 REQUIRED 6.,.-T!-lE TOT AL LANDSCAPE = 2 0, '3!;, 3 SQ.FT. 764S 11111641 ms l!ll!. ' () J.EL5CiN PRESSURE REOOLATING VALVE (IN A SEPARATE VALVE BOX) DIRECTLY DOWNSTREAM OF T14E lf'i!RIGATION FOC.. CITY WATER ORDINANCE. G1JICX COJIUR (RJRFLE COVER! NO.& 6ET THE REGULATING VALVE AT I:,% I-IIGI-IER T!-IAN Tl-IE 5TATED $Y5TEM REQUIREMENT&. $!-IOULD TI--IE STATIC ...... NIBCO T·!lell l!ll!. 6 FRE5SURE BE LESS TI-IAN Tl-IE STATED FRE5SURE, NOTIFY THE CLIENT'$ REFRESENTAT!vE IMMEDIATELY. IN TI--IE BALL VAL ',l: (LINE 51Z£! N0.8 EVENT FRE56URE DIFFERENCES ARE NOT REFORTED PRIOR TO TI--IE START OF CONSTF<UCTION, Tl-IE IRRlc.ATION NOTE SC1-l ,JI) F'VC (f'RE66Ul1JZ£! NANLtE (15' QI< eMAU.fR), CI.A6& 3& (2' QI< LARiER! (f\ffl.E F<ECYCUD I"',(:! l!ll! .• CONTRACTOR 51-!ALL A56UME FULL RE5FON6I61LITY FOR ANY REVISION& NECE56ARY. -IN&TAI.L 3' QI< LES& DIAl'E1ER HANL11E AT I&' DEEP MIHl1J1 N0.6, 1 e CONTRACTO!< TO REPLACE AND REPAIR TO ITS ORIGINAL CONDITION, ANY EXISTIN::i MINIMUM PIPE COVERA.GE INSTALL 3'· ;~• DIAMETER HAIU,I; AT )4' DEEP Hn,IMJ-1 14. ALL 5TATED GALLONAGE IN VALVE CALL-OUTS ARE ROUNDED UP TO Tl-IE NEARE5T GALLON. LANDSCAPE, IRRIGATION 5YSTEM5, UTILITIES, AND STRUCTURE5 UJl-llCl-l l-lAS BEEN A. FRE55URE LINE5, INSTALL 2 LA'l'ER6 C1F IIAliNHS TAFE AllO',l: MAINLINE l!i. ALL 6f-!RUB &FRAY 1--!EAD5 6f-!ALL 6E 12' FOP UFS. ALL BUBBLER$ 6f-!ALL BE IN5T ALLED DAMAGED 13Y CONTRACTORS WORK CONTRACTOR 51-lALL A55UME FULL RE5FONSl13ILITY LE5S Tl-JAN 3' IN DIAMETER • 18' COYER 6CH <ll F'VC /NClll,f'R!:56.l>JZEDJ LATERAL LINE, l!ll! .• FOR Tl-IE COST TO REPAIR AND REPLACE SAID DAMAGED ITEMS. MODIFICATIONS -WITI-I A 2' FOF-UF. 3' TI-IRU 5-112' IN DIAMETER -24' COVER IN$TAI.L ij' DEEP MINl1J1 (l'lffl.E Rl:C'l'CLED PYC! NO.h, 1 AS DIRECTED 13'1' Tl-IE OUNER 61-lALL BE PROVIDED BY Tl-IE CONTRACTOR AT NO 6' OR GREATER IN DIAMETER -36' COVER PVC 61..EEV!,5 CHAIN/.n-JE ,OW LA1ERAI..) "6TALL l'ER 1\lE CITY C1F CARL6BAD STAND,,lliil) l!ll!. 6 lib. ALL ON51TE VALvES, VALVE 60XE5, VALvE MARKERS, !--!EADS, FIFING, AND POU.ER 6UPPLIE5 51-!ALL BE -INSTALLED IN ACCORDANCE WIT!-! Tl-IE REGlUIREMENT5 OF THE CITY OF CARLSBAD WATER DEPARTMENT e CONTRACTOR 51-lALL GUARANTEE Tl-IE SURVIVAL Cf ALL LANDSCAPE PLANT MATERIAL 13. LATERAL LINES, 12' COVER TREIICH DETAIL /61Z£ MINl1J12 Tte TI-E &IZEJ /FIJliF'LE l<ECYCLED PYC! N0.6, 1 5LEE\1a!i LNlER ROAD&. 6' OR LE55 D< DIAME1ER 36' CO'IER (6CH. Sf/I RULE6 ' RECIULATION6. TI-IIS INCLUDES ALL AREAS UJI..IERE DAMAGE 1-lA& OCCURRED DUE TO IN5TALLATlo.l C. 5LEEVE6 UNDER ROADS 5LEE'IE6 LNlER ROAD&. 6' QI< NORE IN DIAMETER -48' COl,£R (eCli 811)/ Cf NEW IRRIGATION 5Y6TEM AND ITS 6URROUNDING AREAS. MODIFICATION6 A& DIRECTED 6' OR LE55 IN DIAMETER -36' COVER 5LEE\1a!i LWER PAYMi (NON•RO"D5>. LEe& 111/,,'1 3' IN Dl.oM:TEI! 18' ~ (6CH. ,JI)) 11. REFER TO Tl--!E CITY OF CARL56AD WATER DEPARTMENT RULES AND REGULATIONS FOR U5E OF RECYCLED WATER AND &LEE'll:5 LWER PAYMi (NCIN·l'!OAD&>. l'•o5' D< DIAl1!1ER 24' COVB< (&c:H. 40/ LOCAL BUILDING CODE&. BY T.JE OWNER TO REPLACE DAMAGED PLANTING MATERAIL &.!ALL 6E PROVIDED BY Tl-IE GREATER 11-lAN 6' IN DIAMETER -42>' COVER &LEE'll:5 LN:£R PAYtti (NCIN-RDAD6!. 6' OR Gl<EA1ER ND-36' COVER CSCl-l. 401 CONTRACTOR AT NO ADDITIONAL COST TO Tl-IE OWNER CONTRACTOR 51-lALL ASSUME D. 5LEEVES UNDER PAVING /NON-ROADS! SCll Sf/ PVC 51.EEVES /ll,li<f/ NSTALL l'ER Tile CITY C1F CARl.6BAD STANDARD l!ll!. 6 ,e. INSTALi.. ALL VALvE BOXES, METERS, BACKFLOW PREVENTER$, BEI-IIND SIDEWALK, OUT OF VIEW. 6' OR LE55 IN DIAMETER· 36' COVER ~ TREIICH DETAIL (5IZ£ AS INDICATQ3lJ (RJl<f'LE l<ECYCLED l'YC/ N0.6, 1 1'3. ALL VALVES, COUPLER 60XE5, AND LID& ARE TO 5TANDARD FURFLE. TAu EQUIPMENT FE!'< THE CITY OF CARL5BAD e IRRIC:iATION A5-6UIL T PLANS ARE REQUIRED. Tl-IE LANDSCAPE CONTRACTOR GREATER TI-IAN 6' IN DIAMETER • 48' COVER WATER DEPARTMENT STANDARD&. VALvE 60XES 51-!ALL 1-!AvE LOCKA6LE TOP$ AND 5ET 2' ABOVE FINl51-1 a.RADE IN 51-!ALL PROVIDE ACCURATE AND LEC:il6LE DIMENSIONS FROM 1-lARD REFERENCE 5!-IFU3 AREA5. NO RCV IN TURF ZONE. 5TENCIL 'V' AND VALVE NUMBER ON LID COVER POINTS, IE. BUILDING EDGES, FACE OF CUR65, AND EDGE OF PAVING. FINAL MINIMUM SLEEVE COVERAGse A5-6UIL T PLANS 51-lALL BE DRAFTED AND 5U6MITTED FOR REVIEW, APPROVAL, SLEEVES UNDER ROADS IRRIGATION PRESSURE CALCS 21Zi. IRRluATION METER TO 6E PROVIDED AND INSTALLED BY Tl-IE CITY OF CARL56AD. IT 1$ Tl-iE RE5FON5IBILITY OF AND 5IGNATURE 6.,.-T!-lE CITY PRIOR TO RELEASE OF SECURITIES. 6' OR LE&, IN DIAMETER -36' COVER TI-IE IRRIGATION CONTRACTOR FOR ALL WATER METER FEES. GREATER TI-IAN 6' IN DIAMETER -42>' COVER WA1ER Plil!:55URE CALCULATION& CClllROLLER llt1eER () <lFM CITY Cf CAALSBAD, CALIFOl,NJA 21. $FRAY 14EAD NOZZLE INFOl'<MATION, WHEN INSTALLINu SPRINKLER !--!EADS USING IOOIZI SERIES NOZZLES Tl4AT 5CI-I 80 PVC 111:JRST CCNDITICI< FICV ~ 111:lRS T CCND ITION FICV MA VAL ',l; 5IZE *--Dlilf'RCY REQUIRE ARC PATTERN& OTHER T/.IAN Tl-IE STANDARD ARC PATTERN /~IZI, lelZI, 3/be>, ETC.! Tl-IE CONTRACTOR 5LEEVE5 UNDER PAVING /NON-ROADS! Plil!:55URE ZONE ~/NEAREST TANK . Plil!:&SU!sE ZONE ~ I NEAFi£5T T Ali< . &HALL USE RAIN6IRD VARIABLE ARC NOZZLES. RADIU5 OF VAN NOZZLES/OR EQUAL! 51-!ALL BE SELECTED LESS TI-IAN 3' IN DIAMETER • 18' COVER IIEl;IIT Cf NEAREST TANK IN PZ(FTJ . ~IGl4T Oi' NEAl'i£5T TANK IN PZ/FTJ . CONDITIONS. EXAMPLE, U5E e-& VAN 1111-iEN e FOOT RADIU5 IS REQUIRED OR 12-12 VAN 1111-iEN A 12 FOOT 3' TI-IRU &-In' IN DIAMl:TER • 24' COVER 5TATIC Plil!:&elJf,f $/l) 5TATIC Plil!:&elll,E $/l) TO MATCH SITE RADIU5 15 REQUIRED. 6' Of< C:iREATER IN DIAMETER· 36' COVER WA1ER METER SIZE 2' WA 113< ME1EI< SIZE l' 22. 06$TRUCTION6, 1111-iEN VERTICAL 06STRLICT/ON$ /STREET LIC.14TS, TREES, MAIL BOXES, ETC.! INTERFERE WITl-l e,cµ 4" PVC WA1ER METER ELEYATICI< 44.8 WA113< ME1ER ELEVATIG1-l 44.8 &FRAY PATTERN OF Tl-IE 5PRINKLER HEADS 50 AS TO PREVENT PROPER COvERAuE, Tl-IE IR!'<luATION CONTRACTOR RC.v. 51ZE I' RC.V.5IZE I-1/l' 6f-!ALL FIELD ADJUST Tl-IE SPRINKLER SYSTEM BY INSTALLING A QUARTER CIRCLE OR HALF CIRCLE SPRINKLER RC.V. ELEVATION ~/l) RC.V. ELEVATION n.1 14EAD ON EACH SIDE OF THE OB6TRUCTION 50 A& TO PROVIDE PROPER COVEl'<AGE. ALL ADJU5TMENT5 6f-!ALL BE RC.Y. DEM;IJ,ID (GPJ1J 13£1 RC.Y. DEMA'ID (GP11.! 12£1 APPROVED FOR MADE AT NO ADDITIONAL COST TO Tl-IE CLIENT. STATIC Plil!:5aJl'i£ • l!C.Y. S2£1 5TATIC Plil!:&SU!sE • RC.Y. !',6J 2~. VALvE LOCATION, ELECTRICAL CONTROL VALvE AND GATE vALvE LOCATION$ 6I-IOU,N ON Tl-II$ DRAWING ARE AFf'lRtENANCE I PIPE Pel L055 / &AIN PSI L055 / &AIN !RR/GA TION ANO PLANTING APPROXIMATE. THE CONTRACTOR 51-!ALL &TAKE OUT EACH ELECTRIC CONTROL VALVE AND uATE VALVE LOCATION 2' WATER METER 0/l) 2' WATER METER 0/l) ONLY, INCLUDING PRECISE FOR REVIEW AND APPROVAL BY CLIENT'S REFRE&ENTATlvE PRIOR TO INSTALLATION OF ALL VALVE&. FINAL LOCATION AND EXACT 2' BACKl'LOW Plil!:V!NTER ~/l) l' BACKFLOW Plil!:VENTER 12£1 FOSITIONIN.u OF ELECTRIC CONTROL VAlvE5 AND GATE VALVE& SHALL BE DETERMINED BY THE CLIENT. MINOR 2' MASTER vALYE lb l' MASTER VAi.Yi: 2.6 LOCATION OF PLANTING MODIFICATION& OF aECTRIC CONTl'<OL VALvE AND GATE VALVE LOCATIONS A$ REQUIRED BY TI--IE CLIENT 6f-!ALL 125' Fl.OW 5EN50R 1.8 12!',' Fl.OJI 5Ei'l50R ts BE PROVIDED BY TI--IE CONTRACTOR AT NO ADDITIONAL COST TO TI-IE CLIENT FAILURE TO OBTAIN CLIENT'S i' BALL YALYE/5! IS 2' BALL YAI.V!:/5! LS AREA. APPROVAL PRIOR TO IN5TALLATION 51-!ALL CAU5E CONTRACTOR TO MAKE CLIENT DIRECTED REVl5I0N6 AT NO IS' l<l:M01E CONTROL YALV!: 32 IS' Fi£MOTE CCl{!lsOL YALV!: ,2 ADDITIONAL C05T TO CLIENT. IN GENERAL. UNLE56 OTI-IERlllI5E DIRECTED BY Tl-IE CLIENT, ALL VAL VE5 61-lALL BE MAN.INE IIEAO &AIN/Loe!l +2.1 MAINLINE IIEAD GAIN/l.055 2.6 "AS BUil T" INSTALLED THREE FEET FROM EDGE OF I-IARDSCAFE, WALK, OR CURB IN PLANTING AREA. LATE'1AL LINE 1-EAD &11"111.055 0£1 LATEl<AL LINE .IEAD &AIN//..055 1)£1 5CII 40 MAINLIIE FRICTIG1-l L055 I/l) 5CII 40 MAINLINE FRICTION L055 (J)b 24. EQUIPMENT LOCATION, i._ocATION OF IRRIGATION EQUIPMENT Sl-lOIIIN ON Tl4IS DRAWING ARE APPROXIMATE. Tl-IE liCll 40 LATEl<AL LNE FRICTIOli LOSS 2£1 5CII 40 LATERAL LINE FRICTION LO&S ts CONTRACTOR 6HALL STAKE OUT ALL IRRluATION EQUIPMENT LOCATION FOR !'<EVIEW AND APPROVAL BY CLIENT PRIOR TO IN5T ALLATION OF Ti-115 EQUIPMENT. FINAL LOCATION AND EXACT POSITIONING OF IRRIGATION ... TOT AL F51 GAIN I LOSS 22£1 TOT AL F5I GAIN / L055 U,J RCE EXP . DATE EQUIPMENT SHALL BE DETERMINED BY THE CLIENT. MINOR MODIFICATION6 OF IRRIGATION EQUIPMENT LOCATION ~~OSCA..oe Call before you Di G DE5IGN Plil!:5Slll<E 'J(j)/l) DE5@1 Fl<ES6!.li£ 30£1 A5 REQUESTED BY TI--IE CLIENT &HALL 6E PROVIDED BY TI--IE CONTRACTOR AT NO CO&T TO T14E CLIENT. FAILURE Avoid cutting underground PSI fll:Glllfll:D &2£1 Pel REGllll<ED ~J ~ ,._ '1,.CBAT◄ -f,pL'! utility lines. It's costly. REVIEWED BY: TO OBTAIN CLIENT'& APPROVAL PRIOR TO INSTALLATION 61-!ALL CAUSE CONTl'<ACTOR TO MAKE CLIENT DIRECTED -5TATIC Plil!:SaJRE 1$/l) STATIC Plil!:56Ul'i£ 1$/l) REVISION AT NO ADDITIONAL C05T TO CLIENT. ~,, 4i 'to ®a" Fi£51DUAL 33£1 Fi£5IDUAL 28.9 ://j " ~~ INSPECTOR DATE ' . ~ ;2!:>. 'FC5' NOZZLE 5CREEN &ELECTION NOTE, ... WI-IEN RADIUS OF &FRINKLER 14EAD5, REQUIRED FOR PROPER COVERAGE. 15 LE56 TI-IAN RADIUS 5HOUJN ON . ,,,, ' . _,_, I SH3ET I CITY OF CARLSBAD CTu ~ lffi LEuEND, T14E CONTRACTOR 61-lALL EQUIP SPRINKLER HEAD WIT!-! A RAIN BIRD 'PCS' FRE6SURE COMFENSATIN.u ~ ' ~ ,r,,: ../..~ SCREEN FOR FLOW AND RADIUS CONTROL SCREEN( OR EGlUALJ FROM FC5 NOZZLE SCREEN &ELECTION CHART FOR Tl-lie IRRIGATION PLAN IS DESIGNED FOR FUTURE RECYCLED PLANNING DIVISION 3 ...... "'" ..,,,, OF C'-'-'~ APPROPRIATE RADIUS. WATER USe. OUNl:R'e ReFReSeNTATIVE TO PROVIDE OR LANDSCAPE IMPROVEMENT PLANS FOR: 1-800-227-2600 ,lb. IRRIGATION $Y5TEM IN5TALLATION 6f-!ALL CONFORM TO ALL APPLICABLE STATE AND LOCAL CODES AND REGULATIONS. DOCUMENTATION OF PAYMENT OF FEES FOR RECYCLED ARMY AND NAVY ACADEMY WATeR REVIEW. IRRIGATION LEGEND/NOTES 21. Tl-IE CONTRACTOR 6f-!ALL REFER TO Tl-IE LATEST EDITION OF Tl-IE 'GREEN600K' 5T ANDARD 5FECIFICATION5 FOR PUBLIC WORKS CON6TRUCTION, SECTION 3€113 FOR LANDSCAPE AND IRRIGATION IN6TALLATION. .._. __ CARLSBAD BLVD. AND BEECH AVENUE IRRIGATION CONTRACTOR TO DOCUMeNT INeTALLATION I APPROVED: l'i:-k\ I AND FROVIDE'AS-6UIL T' DRAWINGse OF IRRIGATION 4-El k>-ft I',.,;.,~ INSTALLATION. LANDSCAPBARCHlTI!CTURE PLANNING 11688S. Saulh81Ret,Sulbe201 OWN BY: I PROJECT NO. I DRAWING NO. Arteola, Califbmla, 90701 PHONE: (562) 860-1021 CA. UC, ftO, 1219 DATE INlllAL DATE INITIAL DATE INITIAL CHKD BY: RL'~ AZ.UC,N0.88Sl'.l REVISION DESCRIPTION RP 12-13 FAX, (562) 860-1091 NV, UC. R0. 78 DESIGNER OF WORK OTHER APPROVAL CITY APPROVAL RVWO BY: RKK 476-SL Emoll, kDbamas~ ----------...... 12'><12~ Pl'<ECA&T &TEP &TONE&. c:0N1'11!ACTOR &MAI I INSTALL AT LEVEL CiRAPE. COLOR, NATURAL c:c:lNCRETEC:£1 ¾' 2 1 4 PROPERTY' LINE 6 HUNTER SPRAY BODIES TO BE LOCATED 24" AWAY FROM BACK OF CURB 7 INSTALL 6" WIDE CONCRETE HEADER PER DETAIL 9 ON SHEET 13 FOR SEPARATION OF POTABLE AND RECYCLED IRRIGATION SYSTEMS EXISTING IRRIGATION TO REMAIN PROTECT-IN-PLACE ·'"'•' .'->'·! "' '. ~-- 3' £L v. A 12 6 "'--'12'><12"c:c:lNCRETE f'IIECA&T &TEP &TONE&. COLOR, NATURAL caNC1l£'TE ~ eel!! DETAIL If'), 6MT IS 6 3 R01.w:--_,, FOC 6LocK l~ATION • STREET STATION NO. ':1+2&~ • USE SITE NO. CA!-!L56AD BLVD.' BEECH • METER SIZE 2' • SERVICE SIZE ______ 2_' -~ • ELEVATION 44.8 • MAX GFM 2A/13 + 34A/12 2!:>£> • POC STATIC PRESSURE 8!:>.rZ> psi • REQ. DYNAMIC PRESSURE _&=6~-~I __ psi • AREA SERVED rZ>.57 acres (irrigated) • ANNUAL WATER USE --~rZ>~.':1~3~ acre fl/yr CONSTRUCTION DRAWINGS THESE 'RECOFm' DRAWINGS ll.ERE PREPARED FROM INFOf.NATION FURNISHED ENTIRELY OR IN PART BY OTHERS. NO WARRANTY, EXPRESSED OR IMPLIED, IS MADE BY THE LANDSCAPE ARCHITECT OF RECORD, AS TO COMPLETENESS OR ACCURACY OF DATA INCORPORATED INTO THESE DRAWINGS AS RESULT OF WORK BY OTHERS. THE ARCHITECT OF RECORD SHALL NOT BE HELD LIABLE NOR RESPONSIBLE FOR ANY UNAUTHORIZED USE AND OR REPRODUCTION OF SAID 'RECORD' DRAWINGS WITHOUT AUTHORIZED PEf.NISSION. Call before you DIG Avoid cutting underground utility lines. It's costly. OR 1-800-227-2600 ALL IRRIGA BE LOCATIE E RIGHT-O - HUNTER TO BE LO M BACK OF NOTE, l~IGATION 5'Y'5TEM IS DESIGNED FOR FUTURE RECYCLED WATER IRRIGATION POINT OF CONNECTION POINT OF CONNECTION 51--iALL BE A NEW 2' DOMESTIC WATER METER WITH A NEW SERVICE LINE. VERIFY THE ACTUAL LOCATION, SIZE AND WATER FRESSURE IN THE FIELD PRIOR TO STARTING, WOF<K. IF ANY OF THE POC INFORMATION SHOUN ON THE51: DRAWING IS FOUND TO BE DIFFERENT THAN THE AC11JAL POC INFORMATION GATHERED IN Tl-IE FIELD, IMMEDIATELY NOTIFY Tl-IE LANDSCAPE ARCHITECT AND IF<RIGATION CONSULT ANT. SHOULD THE CONTRACTOR FAIL TO NOTIFY Tl-IE POC INFot=.MATION, ANY CHANGES REQUIRED BY LOW FRES5URE OR VOLUME SHALL BE Tl-IE SOLE RESPONSIBILITY OF THE CONTRACTOR. PIPE BETILeEN WATER METER AND BACKl'LOW FREVENTER SHALL BE TYPE K =PPER Tl-!15 l~IGATION FLAN IS DESIGNED FOR RJTURE RECYCLED WATER U5E. 3" SLY. ; 5 '1-0 1 I½' WIRE 1 5L V. i .. ' . f I j / ' / I i l I :~ I j'f / ${ I i I !fv ;,f' fw_l I I I I ' I ' ' I ' ' I ' ' ' ' ' ' !~ 8A 1 l Jf I/ I½' H SLV. WIRE ' "::~ ,··-.. ,~ I ' ' -\-. ~ .. \.\ .. \' .. ' ' ' \ \ 1 \ \ ', '-.. ·U ! --- EXISTING IRRIGA N, PROTEC - TO NEW --~=== C '' ! i 1JA ' I ' ' ¾' ____ .::.·.;. ... _ _,_~-~-~~---:::_,...;;,,--~------------------------------(t- I ' ' ' ' ·1A ·:8" .. 1 ' ' ! I ' ' ' ' ' I I -~ ,-,,,-._ - / ; ' ' ' ' ' ' ' , ' ' ' : AR1i11:~c1AL Ftl=LD /ruRP A~A , 1 1 1 Nor IN C:ON1i~Cit. N(p IRFclGA I ION i ' ' ' ' ' ' : '5A 7 1 ' I ' i ' I-IAS 6EEN P:ROv1'iDED. . : ! ,' / r ' ' I ' ' ' I ' , ' 6 ' I ' ' ' ' ' I ' ' I ' ' ' ' ' I ' ' I ' ' ' , • ' ' ' f l i / " // /' , l " j i i ; '' ' ' : ' 1 r .• r /i.. 6,1 I ' I ' I ' 6 ! ' ' HUNTER SPRAY BODIES / TO BE LOCATED 24" AWAY FROM BACK OF CURB / I ' ' ' ' ' I // ' --...::_r / I ~;-. I I I L()I NOTE Sl-4T.4 REDUCED KEY MAP _. ccmRAC'TOR TO liEA.ACe AND 1<!:PAIR TO IT& ORICllNAL CCIOITION, ANY EX15Tt6 LANOOCAF!:, IRR16ATIOO SYSTEMS, UTILITIES, AND &TRIJCTUl,£5 111410! 1¼& l:!EEN DAMAGED BY CCffiRACTORS IIKll'iK. CONTRACTOR !llALL ASelJ1E RILL RE&PONSIBILITY FOR Tl-IE co&T TO REPAl!ii AND REPLACE SAID DAl"!.<l6ED ITEMS. l"'ODIFICATIOOS A5 DIRECTED BY THE CIII-IER SHALL BE l'l<OVIDED BY Tl-IE CONTRACTOR AT NO • CONTRACTOR !llALL ~ THE 9IRVIVAI. OF ALL L.ANDErCAPE Fl.ANT MA1ERIAI. TI-llS INCLUDES ALL AREAS 11,1,ERE DAl"IAGI: I¼& OCCUFftD DUE TO IN5TALLATIOO OF NEW IRRIClATION SYSTEM AND ITS &MllN:>1-6 AREAS. MODIFICATIONS AS DIRECTED BY THE ®(ER TO REPLACe DAMAGED PLANTl-6 HA19'AIL 5I-IAl.L BE FROYIDED BY ™E CONTRACTOR AT NO ADDITIONAL co&T TO THE CIII-IER ccmRACTOR 5I-IAl.L A56U1E LEGEND ~ VIETNAM WAR MEMORIAL LANDSCAPE AREA. PROTECT IN PLACE /,_, SEE Sl-4EET 3 FOR Tl-4E IRRIGATION LEGEND // .. ,""-:'!, I _,F~l I : I SEE Sl-4EET 3 FOR PRESSURE CALCULATIONS SEE Sl-4EET 6n FOR Tl-4E IRRIGATION DETAILS i I ' I OA 3 1 " . -c. -. . ./_ / . ._ • / __ ' 19/i.. 1 1 -----:---~-,,,..__ ~-- ¾' ----. L SLV. \ ' ' ' ' NORT~ 5c::a ls, I' • 20' 20 10 0 20 SCALE IN FEET 1 40 APPRO VEO FOR /RR/GA TION ANO PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. "AS BUil T" V /J /? I._ ss4o BI.. INSTALL 6" WIDE CONCRETE HEADER PER DETAIL 9 ON SHEET 13 FOR ---SEPARATION OF POTABLE AND RECYCLED IRRIGATION SYSTEMS RCE __ _ EXP ____ _ DATE REVIEWED BY: ~-=·~--SC I) \tllJNTER SPRAY j6 BnOCATED 24" A FROlf.-aACK OF SIDEWALK I.a .. LANDSCAPHAROm'BCTURI! 11688E, SauthSln:ot.Sulb,201 Annla,CalilmJla,90701 PHONE: '562) 860-1021 ::~:~= FAX: (562) 860-1091 1'V.t.KJ. no. 78 Email: lwbeteeeer,..@uuiwu.net INSPECTOR DATE I:====:===:===========================:====:===:====:===~ ~ILAN=sH=!=:T=cAP:...':I =EC=1=~T=PR=:==P~=A~::::NN=!==:G=P=~=1~=s~=o==t==~==B=A=D=-=I =3===:I ARMY AND NAVY ACADEMY LANDSCAPE IRRIGATION PLAN CARLSBAD BLVD. ANO BEECH AVENUE I APPROVED: tr4\ lr-~l-4>tt ,., . ,.,..,~ PLANNING OWN BY: I I DRAWING NO. PROJECT NO. DATE INITIAL DATE INITIAL DATE INITIAL CHKD BY: RL RP 12-13 DESIGNER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL RVWD BY: RKK 476-5L IRRl<!IATION OPERA.TING TIMES WATER WINDOW Water Me:ter No: 1 Controller O Water Days Sto. Start Woter M T W T F S S Total No. Times Time 1 2 3 4 5 6 7 Days 1 10 2 10 3 10 4 10 5 10 6 1 10 1 7 1 10 8 1 10 1 9 10 10 10 1 11 10 12 10 1 13 1 10 14 1 10 15 10 16 1 10 17 1 10 18 10 1 19 10 20 10 21 1 10 22 10 23 1 1D 24 10 1 25 1 10 26 1 10 1 27 10 28 10 29 10 30 10 31 10 32 10 33 10 34 10 35 1 10 36 1 10 37 1 10 38 10 39 1 10 40 1 10 41 1 10 42 10 43 10 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Sto. G.P.M. 4.0 13.0 5.0 8.0 1,0 2.0 1.0 1.0 7.0 7.0 3.0 4.0 3.0 5.0 3.0 2.0 2.0 1.0 1.0 3.0 6.0 7.0 6.0 3.0 7.0 6.0 9.0 6.0 6.0 3.0 3.0 3.0 7.0 6.0 6.0 4.0 12.0 1.0 2.0 5.D 6.0 6.0 6.0 Total Gallons Per Yr 13,354.80 1,587.20 7,353.20 9 920.00 5 902.40 3 422.40 8 779.20 383.57 14213.94 19 995.89 740.69 11,758.51 15191.77 740.69 16 160.58 9,920.00 5,902.40 3 422.40 10 974.00 16 033.20 859.73 11,333.60 520.80 1,335.89 2 839.60 9 324.80 608.43 9,920.00 5,902.40 3 397.60 10 974.00 16 033.20 859.73 11 333.60 520.80 4 009.78 1,335.89 2 839.60 9,324.80 608.43 8,394.80 8 394.80 8,394.80 Precip Rote/HR 0.36 1D.69 0.72 10.69 0.08 0.16 0.61 0.20 10.69 0.37 0.47 10.69 0.47 0.47 10.69 0.24 0.41 0.35 0.13 10.69 0.50 0.50 10.69 0.33 0.50 10.69 1.92 0.47 10.69 0.41 0.32 0.22 10.69 0.50 14.44 1.87 10.69 0.42 0.26 10.69 0.36 0.36 0.36 Total Minutes Total Hours 420 7.0 TOTAL 322,322.78 MAXIMUM WATER ALLOWANCE PER MAWA STANDARD. (MAWA) =(Eto)(O. 7)(HA)(0.62) = GALLONS IN C.C.F. = ESTIMATED WATER USAGE FOR THIS PROJECT. (Eto)(PF)(HA)(0.62)/(IE) = GALLONS IN C.C.F. = 417,785.76 558.54 322,322.78 430.91 WATER 50-IEDULE -CONTROLLER 'A' Station No. 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 16 17 18 19 20 21 22 23 24 Days/ Week 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Doil Weeki 14.86 44.59 0.47 1.41 7.43 22.29 22.29 66.88 13.05 39.15 15.29 45.86 41.16 123.47 0.47 1.41 9.36 28.09 9.36 28.09 0.47 1.41 15.20 45.60 9.36 28.09 0.47 1.41 3.83 11.49 0.47 1.41 66.88 200.64 33.44 100.32 41.16 123.47 0.47 1.41 9.36 28.09 9.36 28.09 0.47 1.41 15.20 45.60 Minutes Summer Winter Doil Weeki Doil Weeki 17.66 52.97 7.63 22.88 0.56 1.67 0.24 0.72 8.83 26.48 3.81 11.44 26.48 79.45 11.44 34.32 15.50 46.51 6.70 20.09 18.16 54.48 7.B4 23.53 48.89 1 46.6 7 21.12 63.36 0.56 1.67 0.24 0.72 11.12 33.37 4.80 14.41 11.12 33.37 4.80 14.41 0.56 1.67 0.24 0.72 18.06 54.17 7.80 23.40 11.12 33.37 4.80 14.41 0.56 1.67 0.24 0.72 4.55 13.66 1.97 5.90 0.56 1.67 0.24 0.72 79.45 238.34 34.32 102.95 39.72 119.17 17.16 51.48 48.89 146.67 21.12 63.36 0.56 1.67 0.24 0.72 11.12 33.37 4.80 14.41 11.12 33.37 4.80 14.41 0.56 1.67 0.24 0.72 18.06 54.17 7.80 23.40 , .. 25 3 9.36 28.09 11.12 33.37 4.80 14.41 26 3 0.47 1.41 0.56 1.67 27 3 3.83 11.49 4.55 13.66 0.24 0.72 1,97 5.90 I 28 3 29 3 30 3 31 3 32 3 33 3 34 3 35 3 36 3 37 3 38 3 39 3 40 3 41 3 42 3 43 3 Total Call before you D & G Avoid cutting underground utility lines. It's costly. 22.29 66.88 13.05 39.15 15.29 45.86 16.72 50.16 24.32 72.96 0.47 1.41 10.70 32.10 0.38 1.15 9.36 28.09 0.47 1.41 12.74 38.22 20.58 61.73 0.47 1.41 14.86 44.59 14.86 44.59 14.86 44.59 544.9 1634.9 I 26.48 79.45 15.50 46.51 18.16 54.48 19.86 59.59 28.89 86.67 0.56 1.67 12.71 38.13 0.45 1.36 11.12 33.37 0.56 1.67 15.13 45.40 24.45 73.34 0.56 1.67 17.66 52.97 17.66 52.97 17.66 52.97 636.2 1942.2 11.44 34.32 6.70 20.09 7.84 23.53 8.58 25.74 12.48 37.44 0.24 0.72 5.49 16.47 0.20 0.59 4.80 14.41 0.24 0.72 6.54 19.61 10.56 31.68 0.24 0.72 7.63 22.88 I 7.63 22.88 7.63 22.88 279.6 294.7 RO.W. ALL IRRIGATION MAINLINE TO BE LOCATED OUTSIDE OF THE RIGHT-OF-WAY 0 2' 4 ~3A 1 J HUNTER SPRAY BODIES TO BE LOCATED 24" AWAY FROM BACK OF CURB 4 -. -I 13 .2A / 1 ARTIFlCIAL FIEL)D TUJ~J= AREA 15 NOT IN CQNT1'11:::'..l.!i.CT~--1 1NO IR .· . l-4A5 6 N /FRO 7 --.. _{_ 3 ,13A '1 .5 9 ,14A 1 l ; , . , . . I • ! , ' :v BODIES ---- TO /BE LO D 24"• AWAY fi:RPM BAC OF SIDtHALK . ,'I; i ,' !J i ' -· 'J.'. ---' , I , I 1/ ¾' I" HUNTER SPRAY BODIES I' TO BE LOCATED 24" AWAY 2' $L V. (2) FROM BACK OF CURB ¾' FARKING LOT 16 1 I I I r 1. • 15A 2 1 4 16A 3 0 ...... --- OR 1-800-227-2600 IRRIGATION MAINLINE WIT~IN PROJECT LANDSCAPB ARCHlTBCTURB 1l688E. SoulhS1Ret,Sulte201 LIMIT$, FOR CLARIFIFCATION ONLY --~ Artoala, Calilbrnla, 90701 PHONE;(S62)860-1021 ::~:~= FAX: (562) 860-1091 ftV, UC. no. 78 Emal!: kobe. . -- 11/13' SLV. 1:/I 1:,// I' WIRE I, 11 I 5LV. I I I I 0 ....... 0 3A 5 1 THIS IRRIGATION FLAN 15 DE51C:sNED FOR !=UTURE RECYCLED WATER USE. OLI.NER'S FeEPRE5ENTATIYE TO PROVIDE DOCll1ENTATION OF PAYMENT OF FEES FOR RECYCLED WATER REVIEW. 51-4T.4 ALL IRRIGATION MAINLINE TO BE LOCATED OUTSIDE OF THE RIGHT-OF-WAY 8 1 2 7A 1 1 REDUCED KEY MAF CONSTRUCTION DRAWINGS Tl-!ESE 'RECORD' DRAWINGs5 LUERE PREPARED FROM INFORMATION FURNl~ED ENTIREL T OR IN PART BT OTl-!ERS. NO UJARRANTT, EXPRESSED OR IMPLIED, 15 MADE BT Tl-IE LANDSCAPE ARCl-!ITECT OF RECORD, AS TO COMPLETENESS OR ACCURACY OF DATA INCORPORATED INTO Tl-!ESE DRAWINGs5 AS RESULT OF UJORK BY OTl-!ERS. Tl-IE ARCl-!ITECT OF RECORD 51-!ALL NOT BE 1-!ELD LIABLE NOR RE5PON5I6LE FOR ANT UNAUTl-!ORIZED USE AND OR REPRODUCTION OF SAID 'RECORD' DRAIIJING,5 WITl-!OUT AUTl-!ORIZED PEI-MISSION. LEGEND -.J 2" ~ VIETNAM WAR MEMORIAL LANDSCAPE AREA. PROTECT IN PL.ACE ....... NOTE CONTROLLER 'A' LOCATION RAIN! I EMFEFeA TURE SENSOR VERIFY EXACT LOCATION IN FIELD PRIOR TO IN&TALLATION. IR!'!la.ATION CONTRACTOR 15 RESPONSIBLE FOR ALL LABOR AND MATERIAL& TO CONNECT CONTROLLER TO ELECTRICAL SE-ICE. • CCXIITRACTOR TO F<Ef'LACE AND f<l:PAIR TO IT& ~GINA!.. CONDITICl>I, ANY EXISTn-.. 1.AND5CAPE, IRRIGATION 5Y5W15, UTILITIE5, AND 5mlC1\Jf<l:5 UI-II~ i-lA6 6EEN DAMAGED BY CON1RACTOR5 IU?lsK. CONTRACTOR 51-iALI. A5SUMI: RJLL f<£5PON&IBILITY FOR THE COST TO f<l:PAIR AND REFLACE !!AID DAMA6ED ITEM$. MODIFICATION& t:; DIRECTED BY TIE OllNER 51-iALL BE l'l<OYIDED BY ™E CONTRACTOR AT NO • CONTRACTOR 51-iALL GIIARANTEE THE $URYIYAI. OF ALL LANDSCAFE PLANT MATERIAi. THI& INCLUDE& ALL AliEAS 1118E DAMAGtE I-IA6 OCClffiD DUE TO IN5TAI.LATION ClF NEW IRRIGATICl-4 &Y5TEM AND ITS SI.IRRC\NDn-.;, Af<ft/1,, MODIFICATICI/IIE, t:; DIRECTED BY THE OILIER TO REPLACE DAMAGtED PI..ANT11'6 MATERAIL 51-iAU. BE PROVIDED 6Y Tl-IE CCl<"ll'<ACTOR AT NO ADDITIOl'IAL COST TO THE OIINER CONTRACTOR 51-iALL A961.11E 20 10 I I NORTl-4 5c::ale, I' • 20' 0 20 40 I~~,-~ -·--·-- SCALE IN FEET APPROVED FOR /RR/GA T/ON AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. "AS BUil T" RCE __ _ EXP ____ _ DATE SEE Sl-4EET .3 FOR Tl-4E IRRIGATION LEGEND 5EE 51-4EET 6/1 FOR Tl-4E IRRIGATION DETAIL5 REVIEWED BY: INSPECTOR DATE 1---+------+----------t----t-----t----t----i j SH5EET j CITY OF CARLSBAD ~3 PLANNING DIVISION ~ 1---1---f-----------------+--+---t---J------t :;LAND::::;:::S:::C:::'.AP.;:;E=I:::M::;::P::;R:::O;:VE;:M:::E;:NT~::;P~LA:::N~S;':;F:;OR::::===:::'..'::::==~ ARMY AND NAVY ACADEMY LANDSCAPE IRRIGATION PLAN CARLSBAD BLVD. ANO BEECH AVENUE l---+--+-----------------t--1----t----t-----t I APPROVED: J"t-J\ l.p ~\\.ctr t;-•~-1"!. _PLANNING DATE INITIAL DESIGNER OF WORK REVISION DESCRIPTION DWN BY: DATE INITIAL DATE INITIAL CHKD BY: _,R_,.L"'-- OTHER APPROVAL CITY APPROVAL RVWD BY: RKK PROJECT NO. RP 12-13 DRAWING NO. 476-SL 7 1 Size or dlrectlor chan9s at. dl•tance squa I to I0X pips diameter from flow •en•or tll;:;,rr---1~ll-11 lsi' 1_1,,_iP-1-3 I. Approved Jumbo rsc::tan9ular pla&tlc valve box with l0ci<.ln9 cover. 2. Flnl&h grads 3. 24' extenolor coll• 4. Maot.er remote cot'llrol valve S. FVC SCI-I 80 female adapter, two required. 6. c:.ravel, 12' deep 1. Vln~I ID. tag with c::ortroller let.t.er 8. 6ra•• nipple& ( t~pJ ~ FVC mainline pips from baaJ'low per opeco. I .--\li----------._4 11 l<Z). FVC 4S1 elbow. 11. 6ra•• union -male adapter. 12. '14 UF control wlreo 13. Fentlts Epoxy wire c::ornect.ore 14. Common brlci<.-4 required. IS. 1/4' X 114' wire meeh. 16. FVC mainline to flow •""•or pips per opec. 11. Flow oen&or MASTER VALVE SC.ALE, N.T .5. 4 NOTES, a. All plaotlc:: plpln<l to be onaksd In trenc:liee b. 6unclle • ta~ wTr1n9 at 10' Interva lo c::. Tie• loooe 24' loop In wiring ever~ IIZ>0 feet and at chang<10 of dlrectlor greater than 301. Urtle all loop• art.er all eonneetlone hove been made. d. lnet.all all cont.rot wire or the underolde of the main line pipe. e. Flpe cover for 2' dla. and larqer oholl be 24'. f. Flpe cover For 1-1/2' and omaller-&hall be 18'. 9. Common trench wlt.h other utllltl ... lo prohibited TRENC~ING ,.,.----24' COILED LOOFD SC.ALE, N.T.5. --WATER PROOF CONNECTION (I OF 2! .,----ID TAG ,.,-----vALVe 60X WITl-l COYER, 12 -INCH SIZE -------FINISH GsRADE/TOP OF MULC!-1 --REMOTE CONTROL VALVE, .,--FVC SCI-I 80 NIFFLE CLENGT!-1 AS REQUIRED! M~~ .. ~,.,.----BRICK (I OF 4) ,,--SCH 80 NIPFLE (2-INCH LENl'.:ITl-l, HIDDEN! AND SCH 40 ELL '---PVC SCH 40 TEE OR ELL '--PVC SCH 40 MALE ADAFTER "'---PVC LATERAL FIFE "'--3.0-INCH MINIMUM DEPTH OF 3/4-INCH WASI-IED GRAYEL 7 REMOTE CONTROL VAL VE S<;ALf;, N.T.5. 1 0 JUM6C FLA5TIC VALvE 60X WITH LOCKING, COYE WATEF<FROOF CONNECTION.,__ __ Main lln - Size or directlor change at dl&tanee equal to I0X pipe diameter from f'!ow &ens.or eeneor upstream_ Two (2) corductor, ohellded cable CAEF '.lSl6-25F! c::onnectlor to transmitter .--+,-, FINISH GRADE \_ 5Ize or direct.Ion change at dlot.anee squa I to !;X pipe 6' deep 3/4' dlamet.er from flow oeneor pea gravel oump downotrsam (If required! FLOW SENSOR :GALE, N.T.5. 3 12" 4" MIN. CLEARANCE WARNING TAPE (TWO LAYERS) SLEEVES DEPTH VARIES SEE IRR. LEGEND I ..;;;::::::':::=---pvc CAP (TYPICAL) NOTES, I. ALL PVC IRRIC:,ATION SLEEYES TO 6E SCI-I. 4,Z, OR SCI-I. 5e FIPE. (SEE !RR. LEuEND! 2. ALL JOINTS TO 6E SOLVENT WELDED AND WATERTlu.!T. 3. WI-IERE TI-IERE 15 MORE THAN ONE SLEEVE, EXTEND Tl-IE SMALLER SLEEVE SEE MINIMUM SLEEYE COVERAe:.E NOTE SI-IEET 2 SLEEVE TRENC~ING SCALE, N.T.5. 6 30-INCH LINEAR LENGT OF WIRE, COILED TOP OF MULCH FVC SCH 40 COUPLI FVC SCH 80 NIPFLE (LENGTH AS REQUIRED) PVC SCI-I 40 EL PVC SCI-I 80 NIPFLE,1"-:f~=:::J CLEN:::!TH AS REQUIRE PYCSCH40 '. TEE OR ELL 6ALL VALvE, RAIN Bl MODEL XBV-01S REMOTE CONTROL VALVE, RAIN 6IRD MODEL FES6-l<Z)0 3.0-INC.! MINIMUM DEFTH OF 3/4-INCH WA5HED GsRAYEL VALVE BOX WITH COVER, WATER FROOF 24-INCl-l SIZE CONNECTION (1 OF 2) ID TAG. FVC SCH 80 NIFFLE PVC SCI-! 40 MALE ADAPTER PVC SCH 80 UNION FOR SERVICING ASSEMBLY INLINE FRE55URE REGULATOR, RAIN BIRD MODEL P5I-M40X-I00 FOR MEDIUM FLOW INLINE BASKET FILTER, RAIN BIRD MODEL QKCHK-100 DRIP REMOTE CONTROL VAL VE SCALE, N.T.5. 9 STAINLESS STEEL __ --,:-,I SECURITY ENCLOSURE - LOCKABLE VANDAL PROOF BRAS& RISER, SIZE PER MAINLINE BRAS& UNION!, EACH 5IDE 12" Min (Refer to local Codes} ST AINLES5 !!TEEL BOL T5 to' THICK CONCRETE FAD 3' A60YE FINI51-1 GRADE SLOFE I % TO DRAIN FINISH GRADE NOTES, i----I CU. FT. ,__ __ ~ CONCRETE I. ALL FITTING.$, UNIONS AND RI5ER5 TO 6E RED BRASS. 2. F.C.C. FAD SIZE SHALL 6E SUFFICIENT TO ACCOMMODATE BACKFLOW FREYENTER ENCLOSURE. 3. CONCRETE SHALL 6E 3I0-C-l1 (S20-C-2S00) 4. THE 6ACKFLOW FREvENTER DEVICES AND INSTALLATIONS 51-iALL 6E APPROVED 6Y THE LOCAL DEPARTMENT OF HEALTH SERVICES 4 WATER AGENCY. S. VALYE A55EM6LIES MAY I-IAVE SCREWED FITTINGS OR FLANGiED FITTINGS. 6. AFFROYED TEFLON TAFE, 12mm (1/2') WIDE, SHALL BE USED ON ALL THREADED CONNECTIONS. 1. DISSIMILAR METALS 51-iALL 6E SEPARATED BY AN APPROVED DIELECTIC COIJFLINl'.:i. 8. PLASTIC PIPE 5!-IALL NOT BE USED A60VE FINISHED GRADE. REDUCED PRESSURE BACKFLOW FREVENTSiu,, N.r.s. 2 NOTES: 2 CU. FT. MINIMUM FEAGRA'=- PRESSURE MAINLIN ./ / SCI-I. 40 GAL V. 36' ST AKE___,/ WITl-l 2 SPRINKLER TIES A. Valve box lld oholl be branded lo ldentlf~ quick coupler, """ Brandinq Gulde below 6. Attach recla""Tmed w.aler ldenllfleat.lor taq& or potable water U&ed for lrrl9allon Ident.Jrlcallor t;!qo. C. ACME thread prpe tyj::><1 device for reclaTmed water uee. l<Z)' ROUND VALVE 6CX QUICK COUPLER WI LOCKING COVeR LATERAL LINES TO 5FRINKLER5 6RA55 NIPFLE LENG.TH AS REQUIRED BRASS ':l0 DEGREE STREET ELL D. Pin lock type devl= for potable water uoe. E. 'GMck coupler valve• &hall be of a t~e approved for r~cled water uoe'. QUICK COUPLER SCALE, N.T.5. 5 FINI5H GRADE ---, I' TURF r-ROUND VALVE 60X W/ LOCKING COvER I I FINIS!-1 SURFACE IN FAYED AREA 5!-IUT OFF VALVE SCH 80 FVC PVC UNlnN, (DOWNSTREAM) l+---F--EXTENSION AS REQ'D ,---PVC SxT COUPLING PRESSURE MAINLINE C~~)m:~:m~~;)---COMMON 6RICK (4 FER VALVE! NOTE, ~==,!!li I. AREA AROUND VALVE 6CX CAN BE EITI-IER PLANTED, HARD SURFACE, OR COM60NATION. 2. CLOSE NIFFLES &HALL NOT 6E USED ::l. ALL FIFE FITTINGS SHALL SE PVC SCI-I 80 UNLESS OTHERWISE NOTED. 4. vALvE 60X SHALL BE ONE OF Ti--lE FOLLOWING CA&ES AS &FECIFIED ON PLANS. CASE I -CONCRETE 60X WITH e-----FILTER FA6RIC '----I CU. FT. 3/4' CRUSHED GsRAYEL SC.ALE, N,T.5. BALL VALVE 8 ' ,---' . • ~ ---' !_ osc '(.0~, ... STAINLESS 5TEEL ¾M VANDAL PROOF ENCLOSURE SEE LEGEND FOR SFECIFICATION ---RAIN 5HUT-OFF DEVICE. REFER TO IRRIGATION LEGEND AND 5FECIFICATION. INSTALL THIS SENSOR 11.1-lERE MOST AFFECTIYE r---~~=c!_----IRRIGATION CONTROLLER G GFI TYPE RECEPTACLE W/ ON-OFF SWITCH SURasl: PROTECTOR --TEi-NINAL 5TRIF AND CONTROL WIRES ~-•4 GROUND WIRE ~-I' PVC ELECTRICAL SWEEF FOR FLOW SENSOR WIRES --CONCRETE FAD A5 f'ER CONTROLLER ENCLOSURE MANLFACTURER'S SPECS. ~!-:;-!~~~~-FINISH GRADE ~-3' FYC ELECTRICAL SWEEF FOR LOW VOLTAGE CONTROL WIRES s • 16'. .-----------1' PVC ELECTRICAL SU.IEEF FOR IIIZ> VOLT POWER WIRES. COOR. W/ ELECTRICAL pu,;,e_ If -..__ _____ .3/4' CONDUIT FOR COM-1UNICATION ~--•-------.314' X ~• COPPER GROUND ROD CONNECT AS f'ER ELECTRICAL CODE CONTROLLER ENCLOSURE ASSEMBL 1 SC.ALE N.T.5. 1 ~~ APPROVED FOR /RR/GA TION ANO PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. "AS BUil T" ;!!,,,,--,-4 RC[ __ _ EXP ____ _ DATE REVIEWED BY: INSPECTOR DATE LOCKING CAST IRON COYER. CASE 2 -FLASTIC BOX WIT!-1 LOCKING COVER FLASTIC COYER S. CRU&I-IED ROCK 5!-IALL COYER VALYE 6CX PIFE OPENING TO FREYENT &OIL ENTRY t-------+---+------------+---+--------11---------t-------t/ SH6EET I CITY OF CARLSBAD I SH1E3ETS I PLANNING DIVISION ~='....'=========::;::::::::::::::;:::::;::::;:==:::::'...'==~ LANDSCAPE IMPROVEMENT PLANS FOR: ~-----LANDSCAPll ARCHITJ!CTURE 11688 E, South Stroot, Suite 201 Arteela, C8llfiJmla, 90701 PHONE: (562)860-1021 ~~i:::: FAX, (5fi2)860--109I 1"'.UC.ff0.'18 Email; kDba..._ooc@,mbnn.net DA TE INITIAL DESIGNER OF WORK REVISION DESCRIPTION ARMY AND NAVY ACADEMY IRRIGATION DETAILS CARLSBAD BLVD. AND BEECH AVENUE APPROVED: PLANNING PROJECT NO. DRAWING NO. RP 12-13 476-5L STREET SUl'<fACE 3,5' FOTABLE WATEF< LINE _/ 12" MIN. Q ~ F<ECYCLED WATEF< IRRIGATION MAINLINE IN SLEEYE BASIC SEPARATION STANDARDS 1. PARALLEL CONSTRUCTION: THE HORIZONTAL DISTANCE BETWEEN PRESSURE POTABLE WATER AND RECLAIMED WATER MAINS AND SEWER LINES SHALL BE AT LEAST 10 FEET. 2. VERTICAL CLEARANCE OF 12" MINIMUM IS MANDATORY WHEN CROSSING PATH OF A POTABLE WATER LJNE. INSTALLATION OF CYCLED WATER IRRIGATION MAINLINE 24" FROM FACE OF SIDEWALK WILL PROVIDE THE NECESSARY 10' HORIZONTAL CLEARANCE FROM THE POTABLE MAINLINE IN THE STREET. POTA6LE SERVICE LINE CROSSING SC.ALE, N.T.5. 4 TREE TF<LNK CF<USI-IED c.F<ANI1E ----. FINIS!-1 c.RADE --- c.RA lED CAF (FLIRFLE) ___ .,,. f-lLITNlEF< ri>.se> c.FM FCB BUBBLER ___ _,, f-lUNTEF< f-lVC CI-IECK VALVE (OPTIONAL) ___ _,,- FAlENTED STF<ATAF<OOT ASSEMBLY-----..--....--;~ HUNTER SWING JOINT--~- LATEF<AL TEE OF< ELL LATEF<AL FIFE --~_,, ROOT INTF<USION BARRIER!-----<--..___,_:::::::,/ NOTE: INSTALL HUNTER FlLTER FABRIC SLEEVE- #RZWS-SLEEVE ~1;,• LONc. DEEP WELL TREE 6U66LER ~- I I I ,'Ft=~~~~-== I I I I ~;::::!;;;j:::;t:1:=t~ ~ PLAN (j) AUTOUATIC FUJSH VAJ.VE PWMBED TO TUBING (n'P.) © PVC FLUSH MANIFOLD @ RAJNBIRD DRIPLINE MANIFOL.D-TO- ELBOW CONNECTION (lYP.) © POINT OF CONNECTION @ BACKFLOW PREVENTER © REMOTE CONTROL VALVE WITH FILTER ANO PRESSURE REGULATOR (i) PVC SUPPLY >tANIFOLD © RAINBIRO DRIPLINE MANIFOL.D-TO- TEE CONNECTION @ RAINBIRO XFD-09-12-250 @ AIR/VACUUM RELIEF LATERAL BLANK TUBING CENTERED ON MOUND OR BERM @ AJR/VACUUM RELIEF VAJ.Vf. (YD-5D0-34) PLUUBEO TO RAJNBIRD BlANK TIJBING AT EACH HIGH POINT @) PERIMETER LATERALS 2" TO 4" FROM EDGE @ AREA PERIMETER DRIPLINE INSTALLATION ¾ALE, N.T.$, 8 SC.ALE, N.T.$. 1 1 5IDEWALK . J ·., ",f,11 .-• 24" MElERBOX WIT!-1 MElEF< APPROX, FOTA6LE SERVICE LINE Q RECYCLED WA1EF< IRRIGATION_/ MAINLINE IN SLEEVE BASIC SEPARATION STANDARDS 1, PARALLEL CONSTRUCTION: THE HORIZONTAL DISTANCE BETWEEN PRESSURE POTABLE WATER AND RECLAIMED WATER MAINS AND SEWER LINES SHALL BE AT LEAST 10 FEET. 12' MINIMUM REQUIRED V!:F<TICAL SEFAF<A TION 2. VERTICAL CLEARANCE OF 12" MINIMUM IS MANDATORY WHEN CROSSING PATH OF A POTABLE WATER LINE. INSTALLATION OF CYCLED WATER IRRIGATION MAINLINE 24" FROM FACE OF SIDEWALK WILL PROVIDE THE NECESSARY 1 O' HORIZONTAL CLEARANCE FROM THE POTABLE MAINLINE IN THE STREET. 8" POTA6LE MAINLINE CROSSING SC.ALE, N.T.5. 3 -,1 13 14 15 t,'\ SINGLE-OUTLET DIFFUSER: RAIN BIRD \.:.) DBC025 DIFFUSER BUG CAP ~ 1/4-INCH VINYL DISTRIBUTION \.V TUBING: RAIN BIRD DT-025 ~ 1/4-INCH TUBING STAKE: "-::_,I RAIN BIRD TS-025 BOX: MULTI-OUTLET EMISSION DEVICE: RAIN BIRD XERI-BIRD-KIT SINGLE-OUTLET EMITTER: RAIN BIRD XERI-BUG EMITTERS PC-1032 TOP OF MULCH FINISH GRADE FLEX RISER STAKE: RAIN BIRD RS-025 @ RETROFIT PRESSURE REGULATOR: RAIN BIRD PRS-050 @ PVC SCH 80 CLOSE NIPPLE @ 3-INCH MIN. DEPTH OF 3/ 4 -INCH WASHED GRAVEL PVC SCH 40 TEE OR ELL PVC LATERAL PIPE ZIP TIE ~OTEfHE XBD-KIT INCLUDES: ONE XBD-81 UNIT, 50 FEET 1 /4-INCH VINYL DISTRIBUTION TUBING, EIGHT BUG CAPS, AND EIGHT TUBING STAKES. 6ELOW GRADE DRIP EMITTER A55EM6L Y 5CALE, N.T.5. (i) FINISHED GRADE © 6" ROUND VALVE BOX I 1--1 @ AUTOMATIC FLUSH VALVE © MALE ADAPTER © RAINBIRD BLANK TUBING © RAJNBIRD EASY COMPRESSION ADAPTER (j) PVC PIPE © PVC ELBOW @ BRICK SUPPORTS ® PEA GRAVEL SUMP (18") N01ES: 1. USE ONE FOR EACH INCREMENT OF 7 GPM. 2. FLUSH RATE = D.B GPM 3. SEALING PRESSURE = 2 PSI SECTION/ELEVATION 7 SCALE, N.T.$. AUTOMATIC FLUS~ VALVE 1 SINGLE OUTLET EMITTEF< &ALCO, FST-2 ~-AF'FRO\/ED eACl<l'ILL FINISHGl<ADI: MFR PLUS NOZZLE HARD6CAF£ CURB, WALK. OR .,----FOIJ,IDA TION i----------HlMER FiotO-SEF!IEe 5FRAY60DY PVC 5Cl-l. 00 RISEF! i PVC 5Cl4 4€> ELL5. I T < Tl AND PVC &cM. 80 TH!otEADED Nll"PLE 12" FINIS!-1 C.F<ADE PVC SCH. 80 Nll"PLE LATE!otAL TEE PVC SCH. 4€> &TlotEET ELL. FLEX F<I5EF<, SALCO, F'YCl!-1-I8 FV'C SCI-I 40 lEE OR ELL 0 -- FV'C LATERAL FIFE--,------'~-----,' VINE DRIP EMITTER ON FLEX RISER -·,1~m II I_ IOOOTl!IALL -,, NOTE: ONE EMITTER PER SHRUB, LOCATE EMITTER ABOVE ROOTBALL. THREE EMITTERS PER TREE, TRIANGLE SPACE EMITTERS AROUND TREE CROWN THREE FEET APART. SI-IRU6 EMITTER ASSEM6L 'r' RECYCLEDWAlER DO NOT DRINK INSTALL WITH %" STAINLESS STEEL BOLT AT A MINIMUM OF TWO LOCATIONS. i---~ LENGTH AS REQUIRED. USE 1" DIAMETER WASHER TO PROTECT SIGN. i------1¼" GALVANIZED STEEL U-CHANNEL, OR BOX POST --CONCRETE FOOTING IN5T ALL 5Fl<Nl<LER AT FINl&H GRAD LATERAL l"lf'E SC.ALE, N.T.5. 2 SI-IRU6 SPRAY (POP-UP) SC.ALE, N.T.5. 1 DW OA MT EE SR T RW EA CT LE AR I CLO OE E NT S TT I REG ORN L A L T E I R 0 RECYCLED WATER E>RANDINC:i GUIDE TUBING DEPTH 6" MIN. FROM F.G. I C DW DW DW DW DW DW DW DW OW DW DW DW M E D RW RW RW RW RW RW RW RW RW RW RW RW N COMM GR (STATION #) MV FS GV Fl BS MS SB QC FVA COMMUNICATION SPLICES GROUNDING RODS REMOTE CONTROL VALVES MASTER VALVES FLOW SENSORS GATE VALVES FERTILIZER INJECTORS BASKET STRAINERS MOISTURE SENSORS SPLICE BOX QUICK COUPLERS FLUSH VALVE ASSEMBLY 5CALE, N.T.5. 6 6RAND ING GUIDE SC.ALE, N,T.5. 5 C.M.W.D. RECYCLED WATER PROPER SIGNAGE ALL PROPER SIGNAGE, AS SHOWN BELOW, MUST BE IN PLACE PRIOR TO INSSUANCE OF A JUMPER OR METER FOR YOUR SYSTEM. FAILURE TO INSTALL THE REQUIRED SIGNS PER CMWD STANDARDS WILL DELAY YOUR METER SET, OR REQUEST FOR A JUMPER. IF A SYSTEM IS FOUND TO BE OPERATING ON A JUMPER OR METER WITHOUT THE PROPER SIGNS BEING INSTALLED, WILL BE GIVEN 48 HOURS NOTICE TO INSTALL PROPER SIGNS BEFORE CMWD WILL LOCK OFF EXISTING JUMPERS OR METERS. CMWD WILL NOT BE RESPONSIBLE FOR ANY SUBSEQUENT LANDSCAPE MATERIAL THAT MAY WITHER AND DIE Afi A RESULT OF A JUMPER OR METER BEING LOCKED OFF. REQUIRED SIGNAGE FOR RECYCLED WATER USE AREAS: ALL USE AREAS ACCESSIBLE TO THE PUBLIC SHALL BE POSTED WITH SIGNS (MINIMUM 2 PER METER) THAT ARE VISIBLE TO THE PUBLIC INA SIZE ND LESS THAN 4 INCHES HIGH BY 8 INCHES WIDE. APPROVED FOR /RR/GA TION ANO PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. "AS BUILT" RCE __ _ EXP ____ _ DATE SCALE, N.T.5. REVIEWED BY: 12" RECYCLED WATER POST SIGN 9 INSPECTOR DATE 8 // LANDSCAPE ARODTECTURE 11688 E. South S-. Suite 201 Arte,la, CalJlbmla, 90701 PHONE: (562) 860-1021 ~~'::~ FAX, (562) 860-1091 .v.uc.N0.78 Emal!: lmbataaa~ 1-----+--+-----------+--+--+---+---t I SH7EET I CITY OF CARLSBAD ~3 PLANNING DIVISION ~ ~LAN:::;;D::::S::::C:::A~P:::E=I::::M:::P:::R=o==VE::::M::::E;;N::::T==:P=LAN===s:'::;FO::::R:::::==='-'====::::; DA TE INITIAL DA TE INITIAL DA TE INITIAL DESIGNER OF WORK REVISION DESCRIPTION OTHER APPROVAL CIT'!' APPROVAL ARMY AND NAVY ACADEMY IRRIGATION DRIP DETAILS CARLSBAD BL 'vD. AND BEECH A VENUE APPROVED: PLANNING OWN BY: CHKD BY: ...,R,,..L.,,__ RVWD BY: RKK PROJECT NO. DRAWING NO. RP 12-13 4 76-5L CONSTRUCTION DRAWINGS Tl-lE5E 'l'<E:COF!D' DF<AWING,5 WeRE FRE:PAF<E:D FROM INFORMATION FURNl&I-IED ENTIF<E:L Y OR IN PART 6Y OTl-lERS. NO WARRANTY. EXPRESSED OR IMPLIED, IS MADE 6Y Tl-lE LANDSCAPE ARCl-llTECT OF RECOF!D, AS TO COMPLETENESS OR ACCURACY OF DATA INCORPORATED INTO Tl-lESE DRAWING,5 AS RESULT OF WORK 6Y OTl-lERS. Tl-lE ARCl-llTECT OF l'<E:CORD 61-lALL NOT 6E 1-lELD LIABLE NOR F<E:SPONSIBLE FOR ANT UNAUTl-lORIZED uee AND OR F<E:PRODUCTION OF SAID 'RECOF!D' DRAWING.€> WITl-lOUT AUTl-lORIZED PERMISSION. 0 ' ' . ' ,-~ -_-.-,: =+_ -->-i"""·_'.··-~ ◊ :----j___ --·-..... ··I . . ' ! ! 1 ' ' ' • ' ._-,_,__,._._, ..... .:.=.-....... -.. ......_, ___ ~·-* "--~ ... -----..l....--"~«,, .. :.,., 0 ARTIFICIAL Fl'ELD:TURF; ARgA I NOT IN CONT'RAcr. NO IRRIGA ; ION ~AS BEEN PROVIDED. ::. :~/_ :'/ .. "':) -. : ' ·I I -I I I I 51-!T 2, 51-!T.'9 REDUCED KEY MAP / LEGEND 0) ~ VIETNAM WAR MEMORIAL LANDSCAPE AREA. PROTECT IN PLACE p (/) uil (I} ,, i i!I ti I .. , I I I I I 1-lYDROZONE I PLANT Ko FACTOR 12'.4 1-lYDROZONE 11 -5LOPESAVER2 PLANT Ko FACTOR 12'.6 EXISTING TURF PLANT Ko FACTOR 12'.B NORTl-4 Sc:a le, I' ■ 2fl>' 20 10 0 20 SCALE IN FEET 40 APPROVED FOR !RR/GA TION ANO PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA . "AS BUil T" RCE __ _ EXP ____ _ DATE REVIEWED BY; INSPECTOR DATE I---I-----J------------1-----t----i---~-11 sH8EET I CITY OF CARLSBAD ~3 PLANNING DIVISION ~ ~LAN=:=;~D;SC;A;_;P:;.E:;::::;:IM~PR;O;VE~M;E~NsaT~P:a=LAN~S~FO~R~; ===::~== DATE INITIAL DATE INITIAL DATE INITIAL DESIGNER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL ARMY AND NAVY ACADEMY HYDROZONE PLAN CARLSBAD BLVD. AND BEECH AVENUE I APPROVED: PLANNING /q( lr: ~n~-tt I? •I~• I'; OWN BY; PROJECT NO. DRAWING NO. CHKO BY: RL RP 12-13 4 76-5L RVWD BY; RKK CONSTRUCTION DRAWINGS Ti-lE5E 'RECORD' DRAWINe:.S WERE PREPARED FROM INFORMATION FURNISl-lED ENTIRELY OR IN FART BY OTl-lEF<6. NO WAF<F<ANTY, EXFF<ESSED OR IMPLIED, IS MADE BY Ti-lE LANDSCAPE ARCl-llTECT OF RECORD, AS TO COMPLETENESS OR ACCURACY OF DATA INCOF<FOF<ATED INTO Ti-lESE DRAWINa.6 AS RE6UL T OF WOF<K BY OTl-lERS. Ti-lE ARCl-llTECT OF RECORD 51-lALL NOT BE 1-lELD LIABLE NOR RESPONSIBLE FOR ANY UNAUTl-lORIZED USE AND OR REPRODUCTION OF SAID 'RECORD' DRAWINei,S WITl-lOUT AUTl-lORIZED PERMISSION. 0 .__,..____ t /. I I --0 I I I I /_ I I I I ' .. -··--'--·· --• ----· -- ARTIFICIAL FIELD TU~ AREA I& NOT IN CONT CT. 1NO I~ N l-4A5 e-►N 1FRd ' ' / i 0 ' ! ' ' ' ' i I ,c''' . -, ' ', / ----. --• __ , ,,,', \ ---- . '. , I ... ::.;: .... .:... ' / }'$ > : \ < i -\' I----- , \" . --,,· -·-·7 ·/ .. __ ·;-----➔,: __ ,,,_ ___ r , ' , ' --\· --_·, .::' .• ~ -_. ___ ·_ '.1 ' . -' -.,- . -,. J FARK.INC:i: LOT 16 1 I I I I I I I I I ,- r-...... lteslllt. LANDSCAPE ARCHl'I'l!CTURll I 1688 E. South S1rect, SUlle 201 Arteeia., Calibnia, 9070 l PHONE: (562) 8'50--1021 FMC, (562) 8'50--1091 Email: lmbataaa CA. UC. NO. 1:219 AZ.UC.no.8892 NV. UC. NO. 78 0 --Y--- . ' ' -'i-.. ,_(. "" ~ I I I ' I I LEGEND ~ I SI-IT .a SI-IT.~ REDUCED KEY MAP VIETNAM WAR MEMORIAL LANDSCAPE AREA. PROTECT IN PLACE !-lYDROZONE I PLANT Ko FACTOR 0.4 1-lYDROZONE 11 -SLOPESAVER2 PLANT Ko FACTOR 0.0 EXISTING: TURF PLANT Ko FACTOR 0.8 NORTl-1 &cale, I' ■ 20' 20 10 0 20 SCALE IN FEET AP PRO VEO FOR !RR/GA T!ON AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. "AS BUil T" RCE __ _ EXP, ___ _ DATE REVIEWED BY: INSPECTOR DATE l---+---+-----------t---t----t----t----1 I SHgEET I CITY OF CARLSBAD ~3 PLANNING DIVISION ~ ~LAN====ns==c=AP~E===IM::P:::R:::O::VE:::M:::E:::N::T=;:P:::LAN=;S===FO:;:::R:==='..':::==:::: ARMY AND NAVY ACADEMY HYDROZONE PLAN CARLSBAD BLVD. AND BEECH AVENUE 1----+---+--------------r---i-----i----r---i I APPROVED: ltj I Gr-Ell-c-\r .,.,.,.1~ ,PLANNING DATE INlllAL DE~GNER OF WORK REVISION DESCRIPTION DWN BY: DATE INITIAL DATE INlllAL CHKD BY: ~L~_ OTHER APPROVAL CITY APPROVAL RVWD BY: RKK PROJECT NO. RP 12-13 DRAWING NO. 476-5L PLANTING NOTES: PLANTING LEGEND LANDSCAPE SLOPES: I. CONTRACTOR 51-lALL BE RE5FON51BLE FOR MAKING l-4IM5ELF FAMILIAR UJITl-4 ALL UNDERGROUND 5YM QTY SIZE BOTANICAL NAME COMMON NAME Ko SLOFES 6,1 OR STEEPER REQUIRING EROSION CONTROL MEASURES AS UTILITIE5, FIFE5 AND 5TRUCTURE5. CONTRACTOR Sl-lALL TAKE SOLE RESFONSl6ILITY FOR COST INCURRED A 2!:, 24"BOX ARECA5TRUM ROMANZOFFIANUM QUEEN PALM M SPECIFIED 1-lERIN Si-lALL BE TREATED WITl-l ONE OR MORE OF Tl-IE FOLLOWING DUE TO DAMAGE AND REPLACEMENT OF SAID UTILITIES. PLANTING STANDARDS, 2. CONTRACTOR Sl-lALL NOT UJILLFULL Y PROCEED WITl-4 CONSTRUCTION AS S!-IOWN UJl.lEN IT IS 06VIOUS B 12 24'BOX LAGER5TROEMIA I. BILOXI CRAPE MYRTLE M A. STANDAl'<D I -COVER CROP/REINFORCED STRAW MATTING, Tl-4AT UNKNOWN CONDITIONS AND/OR OBJECT$ EXIST Tl-lAT MAY NOT 1-lAVE 6EEN KNOWN DURING Ti-lE COVER CROP SI-IALL BE A SEED MIX TYPICALLY MADE UP WITI-I OF QUICK PREPARATION OF Tl-lI5 FLAN. 5UCl-l CONDITIONS OR 06JECT5 51-lALL 6E IMMEDIATELY 6ROUGi-lT TO C ,:l 12'BT Pi-lOENIX DACTYLIFERA DATE PALM L Gsl:RMINATING AND FAST COVERING GRASSES, CLOVERS, AND/OR WILD Ti-lE ATTENTION OF Tl-4E CLIENT'S REPRESENTATIVE. Tl-IE CONTRACTOR 51-4ALL ASSUME FULL RESPONSIBILITY FOR ALL 1-!YMENOSPORUM FLA\/UM SUJEET5i-lADE TREE FLOWERS. SUBMIT Tl-IE 5PECIFIC &EED MIX FOR CITY APPROVAL PRIOR TO NECESSARY REVISIONS DUE TO FAILURE TO GIVE SUCl-l NOTIFICATION. D 8 24' BOX L APPLICATION. Tl-IE COVER CROP Si-lALL 6E APPLIED AT A RATE AND 3. ALL EXISTING IMPROVEMENTS, MATERIALS, AND PLANT MATERIAL 15 TO !'i!EMAIN IN Tl-lE E 23 24' BOX GEIJERA PARVIFLORA AUSTRAL IAN WILLOW L MANNER SUFFICIENT TO PROVIDE W% COVERAGE WITI-IIN TI-IIRTY (30) DAYS. CONSTRUCTION AREA, AND 51-lALL BE FROFERL Y AND ADEQUATELY PROTECTED FROM DAMAGE DURING F PODOCARPUS GRACILIOR FERN PODOCARPUS TYPE OF REINFORCED STRAW MATTING SI-IALL 6E AS APPROVED BY Tl-IE CITY CONSTRUCTION. Tl-<E CONTRACTOR 51-lALL REPAIR OR REPLACE ANY EXI5TING ITEM5 DAMAGED OR 8 24' BOX L AND AND STAKED TO Tl-IE SLOPE AS RECOMMENDED BY Tl-IE MANUFACTURER DISTURBED AS APPROVED BY Tl-lE CLIENT'5 REPRE5ENTATIVE AT NO ADDITIONAL C05T TO Tl-lE CLIENT. I 16 !:>GAL AL YOGYNE 1-!Ul;GELII BLUE i-llBl5CUS L REINFORCED STRAW MATTING SI-IALL 6E REQUIRED Wl-<EN PLANTING OCCURS 4. CONTRACTOR 51-4ALL VISIT 5ITE PRIOR TO BID. NO Cl-lANGE IN CONTRACT PRICE WILL 6E ALLOWED BETWEEN AUGUST I& AND APRIL l&Ti-1. FOR ACTUAL OR CLAIMED Dl5CREFANCIE5 6ETWEEN EXISTING SITE CONDITIONS, AND Tl-lOSE Sl-lOWN ON 2 301 !::>GAL CARISSA MACROCARPA 'BOX.W BEAUTY' NATAL PLUM M FLANS, B. STANDARD "2 -GROUNDCOVER 3 268 !GAL DIANELLA CAERULEA LITTLE BECCA L 5. PLANT QUANTITIES INDICATED IN PLANT LIST Sl-lALL 6E VERIFIED 6Y CONTRACTOR 4 63 BGAL DIETES BICOLOR BUTTERFLY IRIS M ONE I-IUNDERD (l(Z)(Z)?'.) PERCENT OF Tl-IE AREA SI-IALL BE PLANTED WITI-I A FROM FLAN PRIOR TO 61D. CONTRACTOR TO PROVIDE AND INSTALL ALL PLANTS AE, GROUNDCOVER KNOWN TO I-IAVE EXCELLENT SOIL BINDING CI-IARACTERISTICS INDICATED ON FLAN. B 184 BGAL i-lEMEROCALLIS i-lYBRIDA (YELLOW) DAYLILY M (PLANTED FROM A MINIMUM SIZE OF FLATTED MATERIAL AND SPACED TO PROVIDE FULL COVERAGE WITI-IIN ONE YEAR). 6. ALL SOIL PREPARATION MATERIALS ARE TO BE STOCKPILED ON 5ITE AND APPROVED 6Y CLIENT'S 6 241 !GAL LIRIOPE MUSCARI 'MAJESTIC' LILY TURF M REPRESENTATIVE FOR QUANTITY AND MATERIALS PRIOR TO IN5TALLATION. 5EE SPECIFICATIONS FOR REQUIRED C. STANDARD "3 -LOW SI-IRUBS SUBMITTAL OF INVOICES AND DELIVERY SLIF'S. 1 141 !::>GAL MUI-ILENBERGIA CAPILLARIS 'LENCA' REGAL MIST M LOW SPREADING WOODY SI-IURBS (PLANTED FROM A MINIMUM OF 2-¾' INCi-i 8 41 BG.AL N.ANDINA DOMESTICA 'COMP.ACTA' I-IE.A VENL Y BAMBOO L LINERS) SI-IALL COVER MINIMUM OF SEVENTY (10%) PERCENT OF Ti-lE SLOPE ,. ALL TREES WITl-l IN !::> FEET TO FAYING, WALLS, AND BUILDINGS Sl-lALL BE INSTALLED WITl-l AFFROVED ROOT BARRIER. FACE ( AT MATURE SIZE). 8. FINISI-I Gf.?ADE TO BE 2' BELOW ALL WALKS, CURBS AND FAYING. '.:J 24 BGAL Pi-lORMIUM TEN.AX '.APRICOT QUEEN' NEW ZEALAND FLAX M D. STANDARD •4 -TREE& AND/OR LARGE SI-IRUBS 9. CONTRACTOR TO GUARANTEE ALL Sl-lRUBS FOR 90 DAYS FROM DATE OF ACCEPTANCE BY Tl-IE CLIENT 10 11 !::>GAL Pi-lORMIUM TENAX 'FLAMINGO' NEW ZEALAND FLAX M TREES AND/OR LARGE Si-ll'<UBS Si-lALL BE (PLANTED FROM A MINIMUM OF I GALLON CONTAINER&) AT A MINIMUM RATE OF (I! PER TWO HUNDRED (2(Z)(Z)) AND ALL PALMS AND TREES, FOR ONE YEAR FROM DATE OF ACCEPTANCE BY THE CLIENT. II 23 BGAL Pi-lORMIUM TENAX 'MAORI QUEEN' NEW ZEALAND FLAX M SQUARE FEET. 112)_ BACKFILL MIX, ALL TREES AND Sl-4RU6 PITS TO 6E 6ACKFILLED WITl-l FOLLOWING BACKFILL MIX. 12 33 BGAL Pi-lORMIUM TENAX 'YELLOW WAVE' NEW ZEALAND FLAX M SLOPES -6,1 01'< STEEPER AND, G!:> FARTS ROCK FREE ON SITE SOIL 4 FARTS NITROLIZED WOOD 51-lAVINGS. 15 LBS. GRO POWER 13 BB !::>GAL A. :3' OR LESS IN VERTICAL HEIGHT AND ARE ADJACNET TO PUBLIC WALK& (5-3-U COMMERCIAL FERTILIZER FER CUBIC YARD OF MIX. PITTOSPORUM TOBIRA 'VARIEGATA' MOCK ORANGE M OR STREET& REQUIRE AT MINIMUM STANDARD "I. PALMS TO 1-lAVE 112)12'% 6ACKFILL WITI-I WASI-IED PLASTER SAND. 14 3e, BG.AL PITTOSPORUM TENU. 'SIL VER S!-tEEN' MOCK ORANGE M B. :3' TO 8' IN VERTICAL 1-lEIGI-IT REQUIRE STANDARDS "I (ERO&ION CONTROL MATTING SI-IALL BE INSTALLED IN LIEU OF A COVER CROP), "2, AND "3. 11. 50IL FREFARATION. ALL PLANTING AREAS TO l-4AvE Tl-4E FOLLOWING SOIL AMENDMENTS IB 84 &GAL PRUNUS CAROLINIANA Ci-lERRY LAUREL M C. IN EXCESS OF 8' IN VERTICAL I-IEIGHT REQUIRE &TANDAl'<D "I <EROSION UNIFORMLY TILLED INTO Tl-<E TOF G!:>' OF EXISTING SOIL. QUANTITIES ARE FER i(Z)€)1Zl SQ. FT. 3 CU6IC YARDS CONTROL MATTING SI-IALL BE IN&TALLED IN LIEU OF A COVER GROF), "2, "3, OF NITROLIZED SI-IAVINGS. 21Zl<Zl LBS. OF GRO FOWER (!::>-3-1} COMMERCIAL FERTILIZER. 16 11Zl6 BGAL Ri-lAPi-llOLEPIS INDICA 'CLARA' INDIAN 1-1.AWTI-IORN M AND •4_ 12. PLANT FITS TO BE FEl'i? Sl-lRU15 PLANTING DETAIL ON FLANS. BACKFILL WITl-l 15ACKFILL MIX AND 11 81 !::>GAL ROSMARINUS OFFICINALIS 'TUSCAN BLUE' ROSEMARY L AREAS GRADED FLATTER TI-IAN 6,1 REQUIRE &TANDARD "I !COVER GROF) COMPACT TO 00% UNLE55 OTl-lERWISE NOTED. PLACE RECOMMENDED TA6LETS 6ETWEEN Tl-lE BOTTOM 18 22 BGAL STRELITZIA REGINAE BIRD OF PARADISE M WITI-I TEMPORARY IRRIGATION WI-IEN THEY HAVE ONE OR MORE OF Tl-IE AND Tl-lE TOF OF THE ROOT BALL, 6UT NO 1-llGl-lER Ti-lAN 1/3 OF Tl-lE WAY TO Tl-lE OF Tl-lE ROOT 6ALL. FOLLOWING CONDITION&. 13. ALL PROPOSED 51-4RU6 AREAS TO BE TREATED WITl-l A PRE-EMERGENT 1-lERBICIDE ,~ 1'.:J BG.AL LIGUSTRUM TEXANUM TEX.AS PRIVET M A. SI-IEET GRADED PADS NOT SCl-lEDULED FOR IMPROVEMENTS WITI-IIN /1, (EFTAM/RONSTAR). APPLY FER MANUFACTURERS RECOMMENDATION, IMMEDIATELY AFTER PLANTING. 20 l'.:J !:>GAL Dl5TICTIS BUCCIN.ATORIA BLOOD RED TRUMPET VINE M MONTHSOF COMPLETION OF ROUGH GRADING. A SECOND APPLICATION MAY 15E APPLIED IF RECOMMENDED 15Y Tl-lE MANUFACTURERS SPECIFICATION 6. A POTENTIAL EF<O&ION PROBLEM A& DETEFiiMINED BY Tl-IE CITY. AND AGAIN AT Tl-IE END OF SIZ' DAY MAINTENANCE PROGRAM. 21 11 !::>GAL PARTI-IENOCISSUS TRICUSPIDAT A 605TON IVY M C. IDENTIFIED BY THE CITY A& I-IIGHL Y VISIBLE AREAS TO Tl-IE PUBLIC OR HAVE SPECIAL CONDITIONS THAT WARRENT IMMEDIATE TREATMENT. 14. ALL PLANTING AREAS TO RECEIVE A 3' LAYER OF 3/4' -I I/Z' PARTICLE 5IZE DECORATIVE BARK. 22 13 !::>GAL ROSEMARINUS 0. 'PR05TRATUS" PROSTRATE ROSEMARY M 23 s BGAL AUCUBA JAPONICA 'VERIEG.AT .A' GOLD DUST PLANT M PERCENT AGES 15. AFTER ROUGl-l GRADING, SOIL SAMPLES SI-IALL BE TAKEN FROM ENOUGI-I LOCATIONS ON Tl-lE SITE TO REPRESENT AN ADEQUATE CROSS &ECTION OF CONDITIONS. SOIL TEST 5!-lALL 6E PERFORMED 6Y A SOIL TOTAL SITE FOR LANDSCAFE 2b,S21 /12.5%) OF 214,442 TESTING LABORATORY (FRE-AFFROVED E3Y CITY) Tl-lE TEST SI-IALL INDICATE BUT NOT LIMITED TO Tl-lE ~ MYOPORIUM PARVIFLORIUM I GAL SQ.FT. 11,084 M TOT AL 5YN1i-lETIC TUl<F AJ.EA 11'1')33 /!',1%/ OF 214,442 FOLLOWING, MYOPORIUM ,. 18' O.C. QTY. !::>,242 LANDSCAFED AF£A 2 FOR EACI-I ZONE ~% fsl:FINED OF 2b,S21 A. Of.?GANIC MATTER CONTENT LAND5CAFED AF£A 3 FOR EACI-I ZONE 6% FIEFINED OF 26.~ 6.N, F,K ~ SLOPES.AVER2 BIO-SWALE PLANTING SQ.FT. 3,404 PAFi!KING TO LAND5CAPE PERCENTAGE C.pH PLANT MA TE RIAL PAFi!<ING LOT 'A' LAND6CAFE, 121 SF (3.1%/ OF 4,085 SF D. EC PARKN::. LOT '6' LAND5CAFE, 1,42!', SF (&.8%) OF 16.~ SF E. SOIL TEXTURE (SILT, CLAY, SAND) CAREX PANSA I CALIFORNIA MEADOW SEDGE -IGAL RANDOM PLANTING,. 12' TO 18" 0,C. TOT AL. LANDSCAPE A A, 26.'a21 SQ. FT. F. REcot-n~IENDATIONS FOR AMENDMENTS, LEACl-41NG, AND MAINTENANCE FEl'i?TILIZATION CAREX TUMULICOLA I FOOTi-llLL SEDGE -IGAL RANDOM PLANTING ,. 12' TO 18' O.C. Tl-IE RESULTS AND RECOMMENDATIONS OF Tl-IE SOIL TESTING LABORATORY Sl-4ALL BE 5UBMITTED TO AND LEYMU5 TRITICOIDES / BEARDLESS RYE GRASS -1 GAL RANDOM PLANTING,. 12' TO 18' O.C. AL.L 'ZONED 2 LANDecAPE' TO fli!ECEIVE APPROVED BY Tl-lE CITY. Tl-lE APPROVED RECOMMENDATIONS FOR AMENDMENTS AND 6ACKFILL Sl-lALL BE 5l5YRINCIUM IDAi-lOENSE BELLUM / BLUE EYED GR.ASS -1 GAL RANDOM PL.ANTING ,. 12" TO 18' O.C. MYOPOfii!IJM PARVlrOLIUM Ae GFeOUNDCOVE~ INCORPORATED INTO Tl-lE LANDSCAPE PLANS PRIOR TO 5TART OF CONSTRUCTION AND Sl-lALL BECOME FART OF Tl-lE APPROVED PLANE,. AGRONO-TEC SEED CO. SLOPESAVER2 -i-lYDROSEEDING lb. 112)12)% OF ALL TREES, STUMPS, ROCKS, VEGETATION, AND ASSOCIATED SOILS PRIMARILY FROM Tl-lE SEED MIX, CONSTRUCTION WILL BE REUSED OR RECYCLED. 50% Ci-lEWINGS FESCUE -FESTUCA RUBRA v. COMMUTAT.A 11. PLANTING LOCATED IN Tl-lE BIO-SWALES Sl-lALL BE FULLY KNITTED IN AND PROVIDE COMPLETE COVERAGE OF 25% Si-lEEP FE5CUE -FESTUC.A OVINA Tl-lE 5WALE AREA IN ORDER TO PROVIDE A WORKING FILTER PRIOR TO PROJECT AFFROVAL. 25% 1-!ARD FESCUE -FESTUCA TRACI-IYPI-IYLLA 18. ALL PLANTING AREAS 51-lALL l-4AVE POSITIVE SUl'i?FACE DRAINAGE OF A MINIUM OF 2% WAY FROM STRUCTURES AND TERMINATING IN AN APPROVED DRAINAGE 5Y&TEM. MULC!-4 l!:,,Z,0•'SI .ACRE AGRONO MULCI-I 19. Tl-lE CONTRACTOR SI-IALL REFER TO Tl-IE LATEST EDITION OF Tl-lE 'GREENBOOK' STANDARD SPECIFICATIONS BINDER I.S GAL/AC FAST TAC FOR FU6LIC WORKS CON5TRUCTION, SECTION 308 FOR LANDSCAPE AND IRRIGATION INSTALLATION. PRE-PLANT FERTILIZER PER SOILS TEST RECOMENDATIONS SEED RATE 10-l2#/l,01Zl!Zl.1Zl!Zl 5QFT PRE-EMERGENT i-lERBICIDE TUPERSAN AT I2•/AC NOTE: ~t2tti◊~tit®iti SLOPESAVER2 PLANTING SEE ARCl-41TECTUAL FLANS FOR ALL SCORELINE AND EXFAN5I0N JOINTS. SQ.FT. '981 AGRONO-TEC SEED CO. SLOPESAVER2 -i-lYDROSEEDING SEED MIX, !:,,Z,% Ci-lEWINGS FESCUE -FESTUCA RUBRA v. COMMUTATA 2B% 51-!EEP FESCUE -FE5TUC.A OVINA APPROVED FOR 2B% 1-!ARD FESCUE -FESTUCA TRACI-IYPI-IYLLA /RR/GA TION ANO PLANTING MULC!-t IB00#'5/ACRE AGRONO MULCI-I ONLY, INCLUDING PRECISE BINDER I.!::> GAL/AC FAST TAC PRE-PLANT FERTILIZER PER SOILS TEST RECOMENDATIONS LOCATION OF PLANTING SEED RATE 10-12•!!,00,Z,.00 5QFT AREA. PRE-EMERGENT i-lERBICIDE TUPERSAN AT I2•/AC "AS BUil T" ~ EXISTING TURF TO REMAIN PROTECT IN PLACE RCE EXP. DATE REVIEWED BY: INSPECTOR DATE ufil CITY OF CARLSBAD CTr] 0 PLANNING DIVISION 3 LANDSCAPE IMPROVEMENT PLANS FOR: ~1>$C4Pt ARMY AND NAVY ACADEMY ~ ,._ -.~r4 "'-t>.:1 PLANTING LEGEND/NOTES ~I" .. ~ -WL CARLSBAD BLVD. AND BEECH A'vf:NUE r:i• ~s I APPROVED: I rcJ! ~ ~\\.d\r . ' . . 1,-1~.J~ 'f?t~~-~~ LANDSCAPE AROil11!CTURE PLANNING L'--DtiTI ~~ 11688 E. South Street, Suite 201 OWN BY: , Artesia, California, 9070 I PROJECT NO. DRAWING NO. l' OF CJ-1..\'i~ PHONE, (562) B<;(}.1021 CA. UC. 1'10. 1:219 DATE INITIAL DATE INITIAL DATE INITIAL CHKD BY: BLC KI,, UC. NO. 8892 REVISION DESCRIPTION RP 12-13 476-SL FAX: (562) B<;(}.1091 NV. UC, l'fO, 78 DESIGNER OF WORK OlHER APPROVAL CITY APPROVAL RVWD BY: RKK Email: lmba.t.HIHM @:uic.""izon.net INSTALL 6" WIDE CONCRITE HEADER PER DETAIL 9 ON SHEET 13 FOR SEPARATION OF POTABLE AND RECYCLED IRRIGATION SYSTEMS LINE OF 51GHT 2S' • 4SDEG. Cal I before you D g G Avoid cutting underground utility lines. It's costly. rn..r.....L.Ju ~iffi OR 1-800-227-2600 ~ ,_. ·" . ,$" ,,,, ._:.· ... ._ -1/1 •·,) -. ~---. .,f "'-FA LOT' CONSTRUCTION DRAWINGS THESE 'RE=RD' DRAWING,$ WERE FFIEFARED FROM INFORMATION FURNISHED ENTIFIEL Y OR IN FART BY OTHERS. NO WARRANTY, EXFFIESSED OR IMPLIED, 15 MADE BY THE LANDSCAPE ARCHITECT OF RECORD, AS TO COMPLETENESS OR ACCURACY OF DATA INCORPORATED INTO THESE DRAWINGS AS RESULT OF WORK BY OTHERS. THE ARCHITECT OF RECORD SHALL NOT 6E HELD LIABLE NOR RESPONSIBLE FOR ANY UNAUTHORIZED USE AND OR REPRODUCTION OF SAID 'RECORD' DRAWINGS WITHOUT AUTHORIZED PERMISSION. I _------------:,------------------·-· --.-----l. ----------------------------------------------------- STOFi!MDRAIN TO BE INSTALLED ON NORTHSIDE OF BUILDING! EDGE WITH IN PLANTER TREES SHALL HAVE ROOTBARRIERS TO FFIOTECT STOFIMDRAIN. ------12•><12~ PlloECA&T &TEP &TONE&. COL""- NA~ CQolCIIIETE Gt¥~ &EE PET AIL W>, eMT 13 MAINTENANCE RE5PON5161L ITY Tl-IE LANDSCAPE MAINTENANCE 51-!ALL 6E T~E ~&FONl61LITY OF ~E NAVY I ARMY ACADEMY. ALL 'AeovE GROUND UTILITIE5' TO eE 5CREENED 6Y AFFROVED LAND5CAPINGs. ALL 'REFINED' PLANTING AFi!EA5 TO RECEIVE HYOPOIU"I PA~R=OLIUM A5 ~COYER I I ' ' ' ' ' ' ' • ' ' I If " ! i l ,'/ I ---, ------:.J. _ I I ' ' ' • . ' ' i ! . ' ' . ' I ' ' ! / /i I• /' .. ./ J 0 ,' / • . ! ' ' i ' } , I ..•• ,. ' ' I ' - , , ' --,-__ ,, , I ' , , , ! • ' , · AR111F1c1kL F~ELD /ruRfi ARftA 1 Not IN toNT:kAct. SEE FIELD / URF/ AND CIVIL DRALlilNG6/. . . ' , ' , . : , , I ' , .' _! / i t I ' ·- / , ' ' ' ' • ' , / I I I , ' ' '. '. i ! t i ' ' ------' i .' . ' ,,.. ./' ·y-. --- • ' • I ' , f j ' f_, .. /- ,.✓ , ,i ! ' • • ' ' ' ' ' . ' I I ' ' :23 SGAL --------/ I I I ~' ~ 5l-4T.11 5l-4T.12 REDUCED KEY MAP VIETNAM WAA MEM~IAL/EXl5TINC!s LAND5CAFE AREA F~IECT IN PLACE SEE 5l-4EET 1~ FOR Tl-4E PLANTING LEGEND SEE Sl-4EET 13 FOR Tl-4E PLANTING DETAILS NORTI-I 5cals, 1' ■ 20' 20 10 0 20 40 I I I 1 I SCALE IN FEET APPROVED FOR /RR/GA TION ANO PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. "AS BUil T" s ··.. &!GMT B •-· l ,4 l) INSTALL 6" WIDE CONCRITE HEADER r..------PER DETAIL 9 ON SHEET 13 FOR SEPARATION OF POTABLE AND RECYCLED IRRIGATION SYSTEMS DATE LANDSCAPEAROnTBCTURB 11688 E, Sauth Street, Sulle201 Artala, Calibma, 90701 PHONE: (562)860-1021 ::~:~= FAX: (5621860-1091 .V.UC.ff0.78 Email; laibate■eK @iaiam.net Hc:iNOL: eeE-OETAIL 8, 61-1EEfl3• .. RCE __ _ EXP ____ _ REVIEWED BY: INSPECTOR DATE lt------+---+--------------+----+---+----+--LITJ CITr:LA~N~G ~!~~SBAD I S1E3TS I 1----1-----+-----------------+--+----+---+---1 ;:;LAN~D;:S;:C;::'.AP,;;E=IM::;=;P:;R:;O;:::VE;:M::;.E~N;:::T~P;:LAN::;;S~FO:;R;::===:::'...'.:::==~ ARMY AND NAVY ACADEMY PLANTING PLAN CARLSBAD BL \ID. AND BEECH A VENUE ■--+------<------------+---+--+----+-----ii I APPROVED: 11'~.:k \ l:s:-~\-ct t----t-----+-----------------+--+----+---+---1 ~P~LA~NrN~IN~G~~~fir=~~~~~~=iFo~~~~ DATE INITIAL I OWN BY: PROJECT NO. I DRAWING NO. DA TE INITIAL DA TE INITIAL CHKD BY: --!R~L,,.__ DESIGNER OF WORK REVISION DESCRIPTION OTiiER APPROVAL CITY APPROVAL RVWD BY· RKK RP 12-13 4 76-SL Call before you oi G Avoid cutting underground utility lines. It's costly. ®TI ~ iffi OR 1-800-227-2600 CONSTRUCTION DRAWINGS Tl-lE5E 'RECORD' DRAWING.5 WERE PREPARED FROM INFORMATION FURNl&l-lED ENTIREL 'Y OR IN FART BY OTI-IER5. NO WARRANTY, EXPRE55ED OR IMPLIED, IS MADE BY Tl-IE LANDSCAPE ARCI-IITECT OF RECORD, AS TO COMFLETENE55 OR ACCURACY OF DATA INCORPORATED INTO Tl-lE&E DRAWING,& A5 RE&UL T OF WORK BY OTl-lER5. Tl-IE ARCI-IITECT OF RECORD 51-!ALL NOT BE l-lELD LIABLE NOR RESPONSIBLE FOR ANY UNAUTI-IORIZED USE AND OR REPRODUCTION OF SAID 'RECORD' DRAWING& WITI-IOUT AUTI-IORIZED FERM1551ON. I MYOf'OIIU1 ,-IEC.,uE""'1J TOeE~ WITI-I h~ 11 AUF. LINE 0 I I I I EMERGENCY ACCESS POINT~, A~TIFICIAL FIELD TURF , A!¢A 15 NOT IN CONt~CT. SEE FIELD TU~ AND CIVIL D~AWING5. _I ,' : D . - FA~ING LOT 16 1 LANDSCAPE ARCHlTllCTURB 11688 E. South Sln,et, Sutto 201 Arteoia, Calllomla, 90701 PHONE: (562) 860-1021 CA. UC. NO. 1219 Kl,. LIC, NO, 8892 FAX! (562) 860-1091 nv.LIC. NO. 78 Email: koba~ B ;2 ;24 BOX LEGEND SI-IT.II Sl-lT.1:2 VIETNAM WAR MEM~IAL/EXl&ITING LAND&CAFE AREA ~TECT IN PLACE SEE Sl-lEET 1~ FOR Tl-IE PLANTING LEGEND SEE Sl-lEET 1.3 FOR Tl-IE PLANTING DETAILS MAINTENANCE RESPONSIBILITY Tf.lE LANDSCAPE MAINTENANCE &HALL 6E Tf.lE RESPONl61LITY OF Tf.lE NAVT I ARMY ACADEMY. ALL 'AeOYE ~ UTILITIE&' TO BE &cFeENED 6Y AFF~'vED LAND&cAPING. ALL 'Fi£FINED' PLANTING AREA& TO RECEIVE MY'OPORLIM PARVIFOLIUM A& G¥i!OUNDCOYER NORT!-1 &cale, I' • 31Z>' 20 10 0 20 40 SCALE IN FEET APPROVED FOR !RR/GA TION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. "AS BUil T" RCE __ _ EXP ____ _ DATE REVIEWED BY: INSPECTOR DATE ~ CITY OF CARLSBAD ~ l---t--t----------------t---t-----i----1r------i ~ PLANNING DIVISION ~ 1---t--t----------------t---t-----i----1r------i ;:;:LAN:::;:;D;:::S::;CAP:'..;;:;E;::;:IM;:P::;R:;:OVE::;:;:M:;E;:NT;:::;P:;:LAN::::;:;S;::::;:FO;:R::::: ==::'....'.:===: ARMY AND NAVY ACADEMY LANDSCAPE PLANTING PLAN CARLSBAD BLVD. AND BEECH AVENUE 1-----+----+--------------t---t----+----+---t I .,_---t_ ~-fa\..o}L l,-1~· 1'!> I APPROVED: i.-, _ ~ \ I_ .il- 1---t--t----------------t---t-----t-----cr------i PLANNING ~D~W~N=;B~Y;:: ::;;:;::;;;;:;--;==:::P:::RO=J:::E:::CT;:=N0:::.=::::;-;1 :::D:::RA=W=IN:::G;::::NO;::. DATE INITIAL DATE INITIAL CHKD BY: RL O'THER APPROVAL CITY APPROVAL RVWD BY: ..LR...,KK"---RP 1 2 -1 3 4 7 6-5 L DA TE INITIAL DESIGNER OF WORK REVISION DESCRIPTION I.IALL LT□P □F I.IALL SCREl.i DR BOLT AS CONDITIONS REQURE I' I.IDNDER TIE DR EQUAL -AS NEEDED I' STAINLESS STL I.IASHER AS CDNDITJ□NS REQUIRE NOTE, Hi,X R□□TBALL l ESPALIERED PLANT DR VINE VINE ON WALL FINISH GRADE GROUND COVER NOTE, PAINT BDL T DR SCREl.i TD MATCH MOUNTING SURFACE. SCALE, N.T.5. 4 STEEL TROWEL FINISH INST ALL 1/4' DEEF' SCORELINE& e 10' OC. CONCRETE HEADER SC.ALE, N.T.5. 9 FINl5!-I GsRADE r--F'RECAST CONCRETE F'AD 12' X 12' SQUARE -o·0 oa -~ 11i' 11 111 111 111 111 111ill II= =Ill= COMF'ACTED 5U66RADE 12' CONCRETE STEPPING STONE 5CCALE, N.T.5_ 1 0 -11 Jc1------Rt.1661:R CINCH TIES OR _ AF'FROVED EQUAL. ~~ ATTACH CINCH TIES TO LODGiE POLE WITH GALYANZIED SCREWS I+-----2-2' DIA LODGiE F'OLE STAKE 10' LONG. --ROOTElALL --WATER ElASIN. REMOVE ONCE F'LANT 16 ESTAElLISHED. --ElACKl=ILL F'ER GiENERAJ.. NOTES FINISI-I e:.RADE NATIVE SOIL 3/4' GRAVEL "i/if:"---FERTILIZER TAElLETS AS 2x ROOTElALL DIAMETER REQUIRED. SEE F'LANTING NOTES '-----ROOT 6ARRIER IN TUR' AREAS. M01EO, ARElOR GUARD REQUIRED TREE PLANTING / STAKING SCALE, N.T.5. 3 .,,,.------.. / ' / ........_ / "- I------:y-o" -----,IL-----s '-'&" -----r • • , 4' I \ I _,.,---TREE -\ I \ \ """'""""r -El' ie ,._, / ,.---ROOT SAFilRIER AL~ PAVING EDGE / \ IN&TALL FER MANU=AC~ Rf:CG1"'t1ENDATlt:Jl'0 __ j__ CCNCRETE PAVINIS TREE ROOT 6ARRIER SC.ALE, N.T.5. 7 • I 1/8' &AWCUT HORT t VERT. &URFACE5 TYF'. ~ PLAN VIEW EQ. • EQ. • EQ. • EQ. • . . . . ";> REBAR HORT. TOP/ BOTTOM 24' I' RADILI& TYP. 1-112' REVEAL ";> REBAR VERT. CAGE e 24' O.C. POURED IN PLACE CONCRETE ~-FINl&H GsRADE TURF NOTE, NATURAL uREY COLOR MEDIUM &ANDBLA&T FINl&l-l MONLITHIC CONCRETE 6ENC!-1 SC.ALE, N.T.5. 8 • 111A 11'1U>Ael>l FINl51-! ~ .,__ffi/---FERTILIZER TABLET!I /FER PLANTING NOTI!&) -+----BAOCRLL FER NOTES SHRUB PLANTING SC.ALE, N,T_5_ 2 LODGEFOLE eECTIQN V2 X DC. 9PA.CR'-i'.i 5EE PLANT Lle6END FOi< OC. 6PACING E8TA1'Ll81l FNl81l GRADE l' BELaJJ FNISll 8iR'ACE OF >W<DeCAPEICUIIB 1/l' Da!P LAY!!" OF NIT1'0LIZED "-""Kl-lJLCH TILLED AND AMENDED Pl.ANTIN5c 6ED F£R Fl.ANTING N011'8. NOlE5, ROTOTILL ARE.le el!ING ~ TO A DE1"114 OF 6'. ISl.!ND AMEND- M:NTe MO NATIVS eofL TO AVOID -"'Y DISTINCT BOIL 1-<lRizetl. BEE Fl.ANTING Lle6END FOi< &FACING D1"1ENOIO<l r-PLANT LOCATION / .,.A_ . /TYP. 8Yl'IIOL) IBIANC;ULAg SFAC!Nas EDGE OF PL-"'TING 0'1i:PAYING GROUND COVER SPACING SCALE, N.T.5. 1 1-!EAFi.? Cf= Fl.ANTING: PIT! SHAU. BE GRADED TO A l: 1 MAX. h-1$TALL Ef<Q&ION OONlROl. ,-e, REAR OF Fl.-"'T~ FIT& 6"ALL eE Cll'ADED TO A I, I HAX. ,.-----INSTALL ER,O&ION. c:a,,/TfW)L F.AeRIC. &. .. LANDSCAPll ARCfDTBCTURE 11688 E. South St,eet, Sulle 201 Artesia, Calilbrnia, 9070 I PHONE: (562) 860-1021 C.-\.UC.NO. l:ill9 AZ. UC. NO. 8892 FAX: (562) 860-1091 NV, UC. NO. 78 &meli; lmbatau~ TIOEE- Ctl0-1 TIE OIOEGllAL (DO NOT TUM6T)----1 I+----2·2' DI.A. LODGE POLE STAKE 1">' LCW. --F100Tl>AL, UJA'!E" e,Ael,( -ONCl! PLANT lo ESTA6Ll!IIED. eAOCFU PEIO GENEIOAL NOTES Fn<15M GIOAD£ ~-314' 6"A\ll!L 111,--FERTILIZER T ABLET5 A5 l'IE<IJI-. E f'L-"'TING NOTES TREE STAKING e SLOPES F'REYAILINi:!a WIND PIFii!ECTION. 5CCALE, N.T.5. 6 • WATER f5Ae!N FINl&H c;RADE o---fJJJ,a!±,---FERTILIZE" TAel.E18 /PE" FLA>IT~ NOTE&) -,1!,!,!ffl!,!,!f---eAOCFILL PER N01E8 SHRUB PLANTING ON SLOPES SC.ALE, N.T.5. 5 uTI 3 APPROVED FOR /RR/GA TION AND PLANTING ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREA. "AS BUil T" RCE __ _ EXP ____ _ DATE REVIEWED BY: INSPECTOR DATE CITY OF CARLSBAD CTr] PLANNING DIVISION 3 LANDSCAPE IMPROVEMENT PLANS FOR ARMY AND NAVY ACADEMY LANDSCAPE PLANTING DETAILS CARLSBAD BL\ID. AND BEECH AVENUE 1--------+-----+--------------+---+----+-----+------1 1-AP_P_Ro_v_ED_= --'l,_~_':{_,,_\,.__~_,_-__,l::\=L=o,\\:..,_____ ., _ ~~,-.. I 1----1----+----------------+---+-------+---+----I ~P~LA7tiN=Nl~N~G ~~~lf==j~~~~==ffoj~~~~- DATE INlllAL DATE INlllAL DATE INITlAL RL DWN BY: PROJECT NO, I DRAWING NO. CHKD BY: ---"'"''-----RP 1 2-1 3 4 7 6 5 L DESIGNER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL RVWO BY: RKK -