Loading...
HomeMy WebLinkAboutDWG 477-5L; SDP 90-05G; PALOMAR PLACE; 01-07RECYCLED WATER NOTES I ALL lll:li<K 5llAU. 6E DC!f IN .ICCORD.lla 11111-11IE ~eeAP lffllCl"AL WA1ER Dl&TRICT'& (Cl1Jt)) m& At{) REGUI.ATla.'& A'lD TI-E &All Dl£60 cou.TT Dl:PARl!1alT OF EN\11~41-EALTI! IDEWl<Et:IJll<l:MEll1!, 2. ALL 1'\131.IC F.ICILITU:& 511::11 ~ CCM'ORI &TATICl.f&, DRN<ll6 FCOOAIN5, DE&klNAlED CU1POOI< EAOO AREAS, ETC, 5llAU. 6E FROlECTED .1441151 COIITACI FRCl'I REC'l'CLED UIAlER SFRAY, HIST OR~- ,. lll:51~FWCTICl:55llAU. 6E 1151:D TO Eln'INATE OR CCM1U TO Tl£ lll:5T EXlEiT l'OS6IBLE, ~I-ti. l<l.N-a-F, O\IER SFRAY At{) Hl&Tlt4 4. ~ ere& ARE STRIC11. Y PR0!-1161TED. &. CROee-cct-l\lECTICl.f& 6E1lll:EN REC'l'CLED WATER LNE& A'lD FO!Aal.£ WAlER Ln-11:S ARE STRIC1L Y PR0!-116ITT:D. b. NO sie&T111JTIIJI OF FIFE HATERl,!J.& 11.U 6E ALLaJl:D IIITIICUT PRIOR AFl'l<OY4 FRCl'I Cl1Jt). 1 ALL HAllll.ltE PIFl:6 5llAU. HAif ~I-ti I.If!: FER Cl1ID At{) DEil, m& A'lD l\'E6ULAT1iJI&. &. I-IOl!<S l'OR l~TIIJI IIH1H REC'l'CLED WATER ARE lffl'l l?>.eiel PM. TO &,eie, AM. Tl£ ~ l'OR llll<llaATIIJI 111111 DI&~ TERIIARY REC'l'CLED 116,lER HAY BE HODFIEP er LOC,dl. AIJ11.IORIT'l'. llll<ll,ATIIJI ~ 1'\131.IC LliE FERIOD5 UITI! Dl&Wi:CTED TERIIARI' REC'l'CLED WATER 5llAU. 6E IWER SiffRvl&liJI OF 11-1: DE&klNATED 1151:R 511'ERY150R. llsl<IGATIIJI 111111 WATER OF A LE5SeR QJ,!J.ITY mJ-1 Dl&llfl:CTED TERIIAl<Y RECYCLED WAlER 5llAU. 6E lll:1llal 11E I-IOl!<S OF l?>.eiel Pl'I. A'lD &,eiel AM. 9. M4 OF ALL ll!Rl)I:; A'lD PIFltti mu t1:!:T Cl1Jt) A'lD Dl-15 l<lll& At{) FEOOI.ATIIJI&. 10. ~-DE&r.NATED USE~ 5llAU. 6E FROTEClED FRCl'I COIITACT UITI! RECYCLED WA~ lll-ETl£R er ll!NDfll.~ SFRAY OR er DIRECT APFLICATIIJI ~ l~TIIJI OR 011-IER LeE. I.ACK CF FROTECTIIJI, 111-ETH:R er DESIGN OR &YSTEM OFERATIIJI, I& smcn. y PROl-llflllED. a llll<llaATIIJI 1-EAD& 5llAU. 6E RELOCATED OR AD.!JSlED TO m:valT O\IERsPRAYN:ri iJI 51DEWALK5, &TRl:ET& At{) ~-DE61:i<ATED USE AREA&. 12. RECYCLED WAlER t:IJIO< CCI.fl.I-ti Y4\f& 5llAU. 6E CF TYFE DE&IGIED l'OR USE iJI REC'l'CLED WAlER DISll<llllJTIClol SYSTEMS A'lD I-IA\1: A $14 CClJFI.ER !<Er FER Cl1Jt) A'lD D115 m& A'lD l<l:GILATIIJIS. 13. r-E& 5llAU. 6E &lll:D er Cl1Jt). 14. iJI RECYCLED WAlER SYSTEMS, ALL ~ (6FRllf(J.l:R i-lEADS, Y41f OOXE&, ETC) 5llAU. 6E COLOR-CODED FER AIIIIIA GUIDEl.ltES At{) eECTIClol lV,61& F Tl£ CALFOl<IIIA f.EAl.111 A'lD 5.IR:TY CODE. 5. ALL IRRIGATIIJI FlFES 5llAU. 6E Slat:11.ED 11111111-E ~I-ti 'f,liJI FO!Ael.E 11!1.lER' OR 'RECYCLED WAlER', COLOR CODED (Mf'IL) At{) LAID IIH1H ~ I.If!: A'lD SKU.S ORENlED TOJW<DS TI-E TOI' CF Tl£ ~FER~ l1lO m& At{) l\'E6ULATIIJI&. f;:()VIDE 7JIO (2) LAYERS OF WARNII\G TAPE. ONE LOCATcD IMMEDIA"ELY ON ·op O' T1E MAit-LiNE PiPE A'1D ON: sOCATED ll INCHES ABOVE THE TOF OF 11-E r AINLl~E. 16. iJI NEIii At{) ell-SITE SYSTEMS CP06T-l'ETElV, FO!PSLJ: 116,TER, WllTAi'lt 1'1,1:551.R i.fCYOLED WATER Atf> UR LN:& 5llAU. 6E l'LACal A MIN1111 CF FOLi< Fm .hf,IR! OR~ Dli.EClcD 6Y 11-E PROJECT Ett:,NEER Atf>IOR l\'E6ULATORY .161:NCY. ~ 5llAU. 6E BE1IIEEN F,!CING ~ACES. NOT Pl'E CENTEl<I.INE&. n. ~TAi'lt i"l<ES5Jl<I: REC'l'CLED 11!1.lER LNE& ill-lAU. CROee AT LEAST IIIEL\f IDa BELCQI FO!PSLJ: WATER LNE& A'lD ill-lAU. MAINTAIN AT LEAST 1111:L If IDa Cl<:)551-ti 51:PARATIClol !lE1Ul:EN OTI-1:R UTILITIES. 11 FA CQIISTAi'lt ~ REC'l'CI.ED IIIAlER HAINLltE PIPE l'ffiT 6E INSTAU.l:D PllM A POTPSLJ: WATER LN: OR LESS mJ-11111:Llf IDa llEJ.l.1II A POTAEU 11!1.TER Lit£, TI-EN 11-E REC'l'CLED WATER LIE mu 6E IN&TAU.l:D 1111111N ilN Al"F'!<0'13l FROTECTl\1: 5I.EEl1: FER ~eeAP l1lO m& A'lD l<l:GILATIIJIS. Tl£ 91.EE\1: 5llAU. EXTEND TEN (10) Fm lffl1 EACI-I SIDE CF 11-E CENTER OF Tl£ FO!PSLJ: LN:, l'OR A TOTAL OF l1lENTY rlll) Fm. l'1 Tl£ FIEGIJIF!ED CROee CC!lECTICN 5flJT DaJN TEST 5llAU. 6E DC!f BY ~ l1lO A'lD Tl£ &All DIEGO COOOY DEPAl<IMEMI CF ~AL 1-EALTI! PRIOR TO 4'11' USE CF FIECYCLED IIIA1Elt 2i?J. Tl£ FIEG!JIFIED CROee-CC!lECTIIJI lil6F1:CTIIJI 5llAU. BE DCI-I: er EIT!-1:R ~ ttlP .IJ-ID/OR 1J.E SilH Dl£60 cou.TT DEPAl<IMEMI CF ENYIRCW-m4 I-U.11l COPIES OR INSFECTICN FIEFOtm 11.lL I'll:~ TO 1IIE ~-INSl'ECTICN P,IR!Y. 21 11-1: DE&IGN ,!HD LOCATIIJl5 Pl<OPOSED l'OR REC'l'CLED WATER 'DO NOT ~• &IGNS 5llAU. 61: CAI.LED 00T CN Tl£ FLilH&. 22. 111-1:N RECYCLED WATER 131:ca-t& AVALA61.E, AA ell SITE USEI< SlffR.150R 5llAU. 6E DE&klNATED IN URIT!t4 TIii& INDIYIDUAL 5llAU. 61: FAMILIAi< UITI! Pl.1.1161NG SYSTEMS UITl!IN Tl£ ~. UITI! 11-E ~IC~ OF ~ CC!lECTICN FROTECTIIJI, 11-E REC'l'CLED RIR\1:YOR'S FW:6 AND FIEGULATICl.f&, A'lD Tl£ SPECIFIC FIEGlliFIEl'IEWT& CF A i.fCYOLED 11!1.TER &Y51Et1 COPIES CF THE DE5klNATIIJI, 1111\l C<:ll!ACT PHCl,E ~ mu 6E ~DEP TO ~eeAP l1lO At{) &All DIEGO cou.TT Dl:PAl<IMEMI OF eMRCW-m4 I-EAi.iil IN CASE OF EMEi.GENC'l" CONTACT GrLl:NN HORTEN&l:N 16et-&,4-16S4■ NAl"E PHONE OR AfTER 1-lOUR& CONTACT c;J..l:NN MORTEN&l:N 16et-&34-16S41 NAl"E PHONE 23. ALL Ra.IC A'lD l'RIYATE POTAEU lll<ITER HAINS ~I-ti FIii£ HAINS ilHD 4'11' 11!1.TER Ulil5 A'lD 11!1.TER COJl<Sl:5 1111111N Tl£ REC'l'CLED 11!1.lER PROJECT Ll11T5 mu 6E ~ CN Tl£ l1PROl1:I-ENT fL.11,1&. 24. CALL M Cll 11-E ~ F 111ERE ARE OR ARE NOT ilHY l)Rllf(INi'i, FCOOAIN5 AND/OR DE&klNAlED cmDOOR EAOO CII SITE. 1&. A FIMICAL 51:PARATIIJI SI-IALL 6E PRO\IIDl:D lll:1llal ADJACOO AREAS IRl<l(jATED 111111 RECYCLED 11!1.TER A'lD POTAlll.f WATER 51:PARATICN 5llAU. 6E l'ROVIDED BY Dl5Tilla, romTI: MOO 61RIP5 OR 01IIER Al"F'!<0'13l 11:1110D&. 2h. ALL IRRIGATIIJI BACl3'1.0III ~ ill-lAU. 61: TESTED BY A CERTFIED TESTER At{) Fll:elJLT511.15T 61: Cill'EN TO Tl£ CITY A'lD Tl£ ~eeAP J1J,ffCIP4 WATER Dl&TRICT. PIFE llE1UEEI Tl£ METER /W e,,a<FLOUJ f'li£VEN1ER ill-lAU. 61: '5Cfl:DIU K HAAD COFFER'. Al"F'!<0'13l CCffil<ACT BACl3'1.0III TESTERS CA>-161: ~ CN Tl£ CITY 111:e SITE AT W.tp,J,malobadc.aSoVl•orvlce,idoparlllon\61wats/DOCWllll6/roo,icledlatsbac:l<!lowleotsllo4'df Far rec,pled or W.tp,J,malobmSoYi6SVlc:ea/doparlllon\61watsiDoc<l'alt6/watsbac:l<!lowleotslt,lpdF rar potabls or cal lbll-438-2122. 21 EDOCATE ALL HAn.11:NAIU ~ CII A CCllTNIII. ~I& OF 1IIE PREiiENCE CF RECYCLED 11!1.11:lt ~ l'I.IST 6E IAA'IEP lllAT RECYCLED 11!1.lER 15 l'EA1'lt FOR t..E SITE$ DE&r.NATED ~ at. Y, ilHD 15 NOT APPROVED l'OR DRN<ll6 ~. HilND IWI.Jl6, CLEA>lll«i CF TOOLS, ETC. Cill'EN Tl£ Hi:;11 ~ RATE CF fflO'fcl:& IN Tl£ LA'lDSCAF£ INDl»OO' IT 16 UfORTAi'lt IHI& ~TIIJI 6E DISSl:MNATED CII M AI.MO&T DAL r ~I&. 28. ALL IMITl,!J. llll<llaATICII ill-lAU. USE POTAel.E 11!1.11:lt NO REC'l'CLED WATER 5llAU. BE USED 0011. Tl£ 5111: HA& PASSl:D 11-E tllTIAL Sf.lJ1DOllN Cl<:)55-cotm;Tlell TEST A'lD I-IA5 lll:EII Ai"f'l<0,13) er ~eeAP l1lO A'lD 1IE 5ilH DIEGO cou.TT DEF ARl!1alT CF ~ 4 I-EAL TII 2' DEl1:L~OR 5HAtJ. cct,JIJlCI A ~mN:Crlell TEST A'lD C0"1:RAGE TEST M Dli.EClcD BY ~ l1lO A'lD Tl£ SilH DIEGO cou.TT Dl:PAl<IMEMI CF eMRCIHNT4 I-EALlll l'RIOR TO ilHY USE CF i.fCYCl.l:D 11!1.11:lt TYPICAL SIGNS 12" X 36"' SIZE / (N. TS ) WARNING RECYCLED WATER DD NOT DRINK RtCYCLED WATER 1A SH HANDS AFTER CONTACTING LAVlSE ·us MANOS DESPLlS DE USAR 1"' BLACK LETTERS 2"' BcACK LETTERS .032 ALJMINUM, .060 ABS PI_ASTIC OR STICK-ON Vll,YL SIGNS RECYCLED WATER SYSTEM (PRIVATE) Landscape Plans for: PALOMAR PLACE DRAWING INDEX SIGNAGE NOTES THE FOLLOWING GUIDELINES FOR THE USE ct RECYCLED WATER ARE TO I'll' Pt~ANENTL T POSTED INSIDE Ti-I: DOOR OF EACH CONTROLLER l:11ERE THEY ARE EASILY VISIBLE. PLACE CII e-1a· X II' SIZED Sk;N. COLOR Al"f'LE BACK6f<DUND UITH BLACK LETTERING. I GUIDELINES FOR RECYCLED WATER USE A IRRIGATE 6ETII.EEN Ti-I: HCiJR5 ct l~,00 PJ'I. AND b,W A/1. 0NL Y. Ul<ITERING OOTSIDE THI& TIME FRAME Hll&T 6E OOlE MANUALLY WITH QJALIFIED SUPERVISORY PER50NNEL ON-&ITE. NO SYSTEM SHALL AT ANY TIME I'll' LEFT JNATIDIDED DURING U5E OOTSIDE THE NOF!iAL SCHEDW.E. 6. ,RRIGATE IN A MANNER THAT WILL MINIMIZE l<!JN-C!f, POOLING, AND POND!NG. THE APPLICATICI< RATE SHALL NOT EXCEED THE 1NF!LTRATION RATE Cfi Ti-I: SOIL Tl1ER511.15T 6E ADJU&TED SO A5 TO I'll' COMPATIBLE WITH THE LOUE5T SOIL NFILTRATICI< RATE PRESENT. THI& P!<OCEDll<E MAY 6E FACILITATED Ill THE EFflCIENT SCHEDIJclNG ct THE />jj!CMATIC CONTROL CLOCK5, fiE., EMPLO,ING Ti-I: REPEAT MICTIC!l 10 BREAK uP THE TOTAL IRRIGATION TiME N10 CYCLES THAT WILL PRCMOTE MAxlMll'I SOIL ABSORPTIC!II. C. ADJUST 5FRAY I-EADS 10 ELIMINATE OVER&FRAY ONTO AREAS NOT UNDER THE CONTROL ct THE CIJSTa'"IER. FOR EXMP~E. POOL DECKS, PRIVATE PATIOS AND LOTS, AND STREETS AND &IDEWALK5. D. MGIITOR A"ID MAl<TAIN THE SYSTEM TO MINIMIZE EQJU"MENT AND MATERIAL FAILURE. BRCl<EN SPRlfl<LER HEADS, LEAKS, LNRELIABLE VALVE&. ETC .• &HOOLD BE REPAIRED A5 SOON AS Tfi:Y 6ECOHE APPARENT. E. THE LANDSCAF£ CctlTRACTOR 15 RESPCl-l&IBLE FOR EDUCATING EACH EMPLOYEE AND ALL MAINTENANCE PERSON1£L C!I A CONTINII005 BASIS, REGARDIIIG THE Fl<ESENCE Cf RECYCLED WATER. MAINTENANCE PE~L HUST I'll' INFOi;!"IED THAT WATER 15 FOR IRRIGATION F'URPOSE5 ONLY AND 15 NOT APPROvED FOR DRII.KING OR FOR flAND AND TOOL WASHING, ETC. F. OBTAli PRIOR APPROVAL OF ALL PROPOSED CHA>&S AND MODIFICATIONS 10 ANr PRIVATE Cl<-SITE FACILITIES. SUCH CHANGE& Mll&T 6E SU6MITTED TO, A"ID APPROvED SY. Ti-IE DISTRICT Ett:,INEERING CFflCE AND DE51:;NED IN ACCORDANCE WITH DISTRICT 51#1:lARDS. l ALL RECYCLED WATER SPRl~JKI.ER CONTROL YALYE5 51-!All l'l!' TAGGED WITH IDENTIFICATICI< TAGS. A TAGS SH.ALL eE u.EATHEFffiOct PLA5TIC, l'x 4', F'URPLE IN COLOR WITH THE WORDS 'WAR-lift; RECYCLED WATER· DO NOT DRINK' 11PRINTED Cl< ONE SIDE, AND 'AYISO • AGUA IMFIJRA· NO Ta'"IAR' IMPRINTED C!I THE OTHER SIDE. llfflNTING SHALL BE PE~A"ENT AND BLACK IN COLOR. U5E TAGS A5 MANUFACTURED 6Y T. CHRISTY ENTERPRISES OR APPROVED EQUAL. 6. ONE TAG SHALL 6E ATTACHED TO EACH YALYE AS FOLL0\1.6, I. ATTA!"~ 10 VAL VE STEM DIRECTL T OR WITH PI.A5TIC TIE-WRAF' OR 2. ATTACH 10 SOLENOID UJRE DIRECTLY OR. WITH PLA5TIC TIE-WRAP OR 3. ATTACH TO VALYE COYER WITH EXISTING VALVE COVER 60LT. l. ALL &PRll>KLER HEADS &HALL 6E IDENTIFIED AS REClCLED WA11:R SPRINKLER HEADS. G. E.OCH tlJTa'"IATIC CONTROLLER AND 115 ASSOCIATED EOOIPHENT SHALL I'll' IDENTIFIED WITH A SIGN l'J!'ARING THE WORDS 'RECYCLED WATER U5ED FOR IRRIGATION' IN ENGLl&H AND 5PAl>ll51!, WITH BLACK LETTER& I' HIGH C!I A F'URPLE 6ACKRalND. THE >1:;N SHALL BE PLACED 50 THAT IT CAI>! 6E READILY 5EEN llY ANY OFERATION5 PER&CII-IEL UTILIZlr,t; THE EQJIPl'fNT. DECLARATION OF RESPONSIBLE CHARGE: I HEREBY DECLARE THAT I AM LANDSCAPE ARCHITECT OF Ul'.)Fl( FOR THIS PROJECT. THAT I HAVE EXERCISED RE5PON5113LE CHAR'.iE OVER THE DE516N OF THIS PROJECT AS DEFINED IN 5ECTICN 1o 103 OF THE 13U51NE55 AND PROFESSIONS CODE AND THAT THE DE516N 15 CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWIN:.iS AND 5PECIFICATICN5 13"!' THE CITY Cf CARLSBAD AND SAN DIEc;Q COJNTY DEPARTMENT Cf ENYIRCt-iMENTAL HEAL TH 15 CONFINED TO A REVIEW ONLY AND DOES NOT RELIEVE ME, AS LANDSCAPE ARCHITECT Cf Ul'.)FJ<, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. THESE PLANS HAVE BEEN PREPARED IN 5Ul3STANTIAL CONFO,?'!ANCE WITH THE APPROVED LANDSCAPE CONCEPT PLAN, WATER CONSERVATION PLAN, FIRE PROTETION PLAN AN ALL CONDITIONS OF APPROVAL RELATED TO LAND5CAPNG. AI-ILES LANDSCAPE ARCHITECTURE PO BOX 1503 RANCOO SANTA FE, CA 92061 ~1%-8%~\ I Sie,.,-t,,...~ ll FE6 13 6TEVEN M. Al-lLE6 RI.A• 2538 EXPIRATION -30-&EP-2013 WATER EFFICIENT LANDSCAPE DECLARATION: I Al1 FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CCNTAINED IN THE CITY Cf CARLSBAD'S LANDSCAFE MANUAL I WATER EFflCIENT LANDSCAPE REGULATICNS. I HAVE PREPA'<ED THIS PLAN IN C~PLIANCE W!TH TH06E RE6ULATICNS A~D THE LANDSCAPE MANUAL. I CERTIFY THAT THE PLAN IMF\.EMENTS THO6E REGULATIONS TO PROVIDE EfflCIENT U&E OF WATER AHLES LANDSCAPE ARCHITECTURE PO BOX 15"3 RANCOO SANTA FE, CA 92061 e,e-1,&-e91o~\ I Qe.-v..,_~ l7FE613 STEVEN M. AHLES RI.A 1 2538 EXPIRATION -30-&EF· 2013 In Order to Conserve Waler ... DI RT DIAL TOLL FREE S!/£ET CCl'/TENTS Palomar Airport Road Carlsbad, California L-1 L-2 L-3 L-4 L-S L-6 L-1 TITLE SHEET, NOTES FL.JNTm F'LA'l, LEGEND FLANTm PLAN, NOTE Pl.ANTI~ DETAILS, ilPECIFICATlc+IS IRRIGATION PLAN, LE'"£-O lr.RIGATION DETAILS, sPECR'ICATICNS IRRIGATICN DETAILS, ilPECR'ICATIM SITE MAP ---~·-~~-~ RECYCLED Pac=· ,.,..,, .. ~~AIIIN::stlolL '-t,''[ ~ -. -T. -~· . ~~~:~Mm. FK.l'fKEfWIJI ,,--'"_::· .... :"_}: ',-J ..... • ~~~, / lll-5D~A'LJ'IV ~ ..• ,. -," ., ' ' C tt ' C C C !, ll ' ' PROP VIA illl WI~ INSPECTION PROCEDURES IN&PECTION SHALL BE PERfORMED BY THE LAND&CAPE ARCHITECT OF Ul'.)FJ<, OR HIS DE&IGNATED AGENT. RE•ER TO THE SPECIFICATIONS FOR THE SCHEDULE OF REG!JIRED IN&PECTONS AND REQUIRED 6UBMITTAL5. FOLLOUJINC. COMPLETION O FTHE Ul'.)Fl( THE LANDSCAPE ARCHITECT WILL CERTIFY THAT THE IN5TALLATICN HA& BEEN COMPLETEDD BY 6U13MITTI~ THE 'FINAL LANDSCAPE CERTIFICATION FORM'. A REQUE&T FOR A FINAL LANDSAPE IN&PECTICN BY THE c1rr MU&T ALSO 13E MADE BY CALLI~ THE INSPECTON REQJE5T LINE, 'FINAL LANDSCAPE CERTIFICATION FOl<J1 FAX TO 160-944-8943. LANDSCAPE INSPECTION REQUEST PI-IONE LINE: 160-602-4602. I. DISTRICT CON&T~TION IN5PECTICI< SHALL INCLUDE, A REQJIRED 5EPARATIC!l l'l!'T\i!:EN POTABLE Al-IP RECYCLED WAlER LINES (HORIZON14LY AND YERTICALL Y!. 6. PIPE IDENTIFICATIOI-! C. SLEEVING AT CRO&&INGS. D. APPROPRJATE MATERIALS #0 Ht,mNGS, INCLUDING PROPER QUICK COJPLEisS. AN APPROVAL LETT"oR REGARDINu THE IN5PECTICI< Cf THE PROJECT SHALL I'll' OBTANED FROM THE CITY AND THE DISTRICT, AND I'll' FOFlilARDED TO THE COONTY -IEALTH DEPARffiT PROR TO FINAL :N&PECTiON APPROVAL. 2. DISTRICT FINAL IN5PECTICI< &HALL INCLUDE, A SIGNAGE INSTALLED PER Pl.Ali fl. CCWROLLER STICKER&. C. TAGc,IN:; Cfi VALVES. D. COVERAGE TEST AFTER COMFLETICI< Cf THE SPRlfl<LER SYSTEM TO EN&URE PROTECTION C1' AREA NOT APPROVED FOR RECYCLED WATER USE. E. ALL ASPECTS OF THE IRRIGATICI< CONDITICNS INCLUDING WINDBLOl!N SPRAY, l<!JNC!f, AND PONDING. F. REQJIRED PROTECTION C1' ALL RESIDENTIAL AREAS. G. REGIJIRED PROTECTION Cfi u.ELLS, STREAM&, RESERVOIR&. ETC. H. CRDSe-rott:CTIC!I TEST. I. COLOR CODED, L/ll"IINATED CHARTS INSIDE EACH CONTROLLER. 3. ANNUAL INSPECTION &HALL INCLUDE, A COMPLETE INSPECTION THAT WILL CO'YER A·I CF THE DISTRICT FINAL INSPECTION. REYl51C!l5 HU&! I'll' APPROVED SY PIJ6LIC HE4TH ENGINEER CITY ENGINEER AND DISTRICT EN:.INEER PRIOR TO IMPLEHENTATICI< IN FIELD. 1 -800-422-4133 DEVELOPER/ APPLICANT DMH ME PALCMAR PLACE, LLC ~838 STABICK CT. 5AN DIEOO, CA ~130 CCNTACT HICK FOUSSIANES SS&-231-1691 NICl<Ftil115510NEGUITIE5.CG11 LEGEND, ~ AREA Cf ON61TE RECYCLED WATER U&E -RECYCLED WATER IRRIGATION MAINLINE POTABLE WATER MAIN FIRE &ERVICE (FOTABLE) RECYCLED WATER MAIN POT ABLE WATER METER RECYCLED WATER METER 13ACKFLOW PERVENTION 'DO NOT DRINK' SIGN OMISSION STATEMENT: HO WALL OR TUFf MCtlNTED AIR INT AKES ARE PROPOSED. NO OUTDOOR DRINKINu FCIJNTAIN, PLAYGROJ"ID&, SUJIMMINu POOl.5 OR IIIELLS ARE PROPOSED. HO Ii.ELLS ARE LOCATED ON THE PROPERTY. AN OOTDOOR EATING AREA (LUNCH PATIO! 15 PROPOSED AS INDICATED ON THIS Pl.AH. ~ NORl1-I ti!& CITY OF OCEANSIDE H!GhWAY /8 PACl,IC CCEAN CITY OF ENCINI AS NOT TD SCALE CITY OF VISTA l COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEAL TH LAND AND WATER QUALITY DIVISION GLENN LEEKS ENVIRONMENTAL HEAL TH SPECIALIST c , i I r t DATE ) AHLES LANDSCAPE ARCHITECTURE INC. P.O. Box 1503 Rancho Santa Fe, CA 92007 858-756-8963 PR0£CT NO: w 0 <( _J o_ a: (/) <( z <( _J ~ (l_ w 0 (l_ <( 0 _J (/) 0 <( z :5 o_ I SET ISSUE 1218 <( -z 0: 0 LJ_ _J <( 0 0 <( co (/) _J 0: <( 0 DA,E INITIAL CD 31 JAN 13 PLAN CHECK SMAR 13 PLAN CHECK 14 MAR 13 RW PLAN CHECK 21 MAR 13 SHEET: L.1 APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. 'AS BUILT' DATE T!TLE REv1EWED BY: INSPECTCf1 DATE CARLSBAD MUNICIPAL WATER DISTRICT RECYCLED WATER IN USE DO NOT D~INK NO TOME EL AGUA AT LEAST TWO DAYS BEFORE YOU JIG UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA f----+---+-------------"-~-·· ···--+---+--I SHE,ET, I CITY OF CARLSBAD I SHE1ETS I ~===-..':::::===:=PL:::A:::::N::::N::::ING::::::::::D:':::IV:=ISION========--===~ PRIVATE (ON 51TE! RECYCLED WATER 5Y5TEM FOR: WASH HANDS AFTER CONT ACTING LAVES[ SUS MANOS DESPLJES DE USAR :8" X 18" SIZE .032 AcU✓,11,UM, .060 f,BS PLASTIC OR STICK-ON VII-JYL SIGNS CARLSBAD MUNICIPAL WATER DISTRICT DEVELOPERS NAME: ADDRESS: REVISION DESCRIPTION ·-- DATE INITIAL DATE INITIAL CITY APPRJ\I AL OTHER APPfDVAL I APPROVED< OWN BY: CHKD BY: FIELD BK: PALOMAR PLACE PALOMAR AIRPORT ROAD CARLSBAD, CALIFORNIA 1~;) l tr-f.:.IL~it '1-l"'L1~ MNNlf.13 DATE PROJECT NO., DRAWING NO.• 5DP 90-0:i(G) 477-:iL CITY SLOPE ST AND ARDS AL THOLkiH NO MANUFACTURED SLOPES, NEU/ OR EXISTING, ARE ANTICIPATED OR SHOJ.N ON PROJECT CIVIL ENGINEERING PLANS, THE FOLLOU/ &TANDARD& WILL BE APPLIED SHOJLD SLOPE BE INDICATED ON FINAL FROJECT GRADING OR IMPROVEMENT PLAN&. &LOPES: AJ 3 FEET OR LE55 IN VERTICAL HEIGHT AND ADJACENT TO p,Ji3LIC 11/ALK& OR STREET& REG!JIRE AT A MINIMUM STANDARD' /COVER CROP OR EROSION CONTROL MATTIMGJ. BJ GREATER THAN 3 FEET TO 8 FEET IN VERTICAL HEIGHT REQUIRE &TA~DARD5 ~ (EROSION CONTROL MATTING &HALL BE INSTALLED IN LIEU OF A COVER CROP), '2, AND '3. CJ IN EXCE5& OF 8 FEET IN VERTICAL HEIGHT REQUIRE STANDARD&~ (EROSION CONTROL MATTING &HALL BE IN&TALLED IN LIEU OF A COVER CROP!, '2, '3 AND 14. . ,~ STEM WALL & IVAER PROOFING SIGHT LINE PER CALTRAN5 STANDARD& NO LAND5CAPE OVER 30 IN. HIGII IS PROPOSED WITHIN VIEU/ CORRIDOR APPROXIMATE LOCATION ONLY 15 5HOII/N. THl5 AREA 15 NOT A PART OF THIS PROJECT AND HA5 NOT BEEN RE-ENGINEERED. r RECYCLED WATER EASEMENTS I ' L I PLANT LEGEND Tl/Ex Pi-ANTS OR SPECIES i!J/TIJ SIMILAR O14!?4CiER!ST!CS 4,'1: PROPOx[), F!.AWS L/STE0 i!J/TllaJT S)M£JOL MA r /3E INCOR?ORA TW INTO FIi/Ai. US/ON AfFROX -£""~s"'-rn""''f!OL £JOT4N!CAL NAME C0/1MCJ/I IIA/1E S!E Ql)ANT!ir & 1-lOLL Y O;IK GLEDITSIA T. INE~IS 'SHADEMA&TER' l-!a-lEY LOCUST 24 IN. 60X &TAt-DARD 24 IN. 60X 13 6 TRl&TANIA CCWERTA 24 IN. 60X 4 ~;,IJ.ECA&TRLH ROJ'!ANaflANUM QUEEN PALM TRANSf'L.<lN1ED II ~ SITE-~ FT. 6TI-I MIN. ARECA& 1RLM Ra"IANOFFIANtJ1 QUEEN PALM 24 IN. 60X S &HRUB5 A C/ILJ.1511:HON 'LITTLE JOl.t,j' (D PHORll'U'I 'JACK l!FR6,1l' 0 CARJeeAa 'Cl!<l:EN CAlft1' 0 \ ', JI.NIFl:J;lJ& CClftRTA CB ?i' CORD'YUE PAZZLE!<' DRACAl:NADRACO VINES " ECI-EVERIA ttAl)IA LOA' @ ECI-E\IERIA 'el:ClHDA' ~ EUPHORBIA X. HARTNII 'RED HARTIN' ~ LkilJ&TRl.l1 JAl'CNICll11EXAl'U1' ~ MORAEA IRIDIOW ¥ l'IIORl11J1 'mlOlll:R' 'V& BOOOAINVli.LfA 6D Fll:D GROJ~DCOvERS 10 FT. 6TH MIN. 4 M!Nii'.1',11 CF sci CF T/IE TOTAL Silfi/Jf!S (£Xa/J/)/N(j Si.OF£ f'l.4NT/N(jS) SI/ALL 13c S 64LLCJ/I OR L/.fefJfl< Sil£ AT !NSTALLAT!CJ/1 ~ flOT11.I: 6"11511 5 GAU.ell &3 DIIIAlif NEW ZEAUJ'lD IUX 1 GAU.CW m FRO&n.Alo NAT,61. PI.I.M 5 GAU.ell 49 5lffl .U.lffl 5 GAU.ell 28 CORDYLINI: !; GAU.CW a DRAGCWlffl 241NBOX I 1-1:N 41N.POT ~ I-EN AND CIIICKS 4 IN. POT 42 CRO!il,I Cf TI-IOl<N5 1 GAU.ell 16 FRlvET 5 GAU.ell 14 FOll!Nkil-lT LILY 5 GAU.ell 29 NIIJ ZEAUJ'lD IUX lo GAU.CW n lo GAU.CW STAKEO AHLES LANDSCAPE ARCHITECTURE INC P.O. Box 1503 Rancho Santa Fe, CA 92007 858-756-8963 PROJECT NO; w 0 <( _J o_ 1218 <{ PROPERTY LINE~· ·. I I ------i. rl I --..____--DEEP FOOTING rr~7s.so P1\D= / I, /~1 ~-__J ~ Sl:NECIO MAHDl<AI.ISCAE 11V ~ ~1111 FEL TA11.t1 Sl:NECIO Fl.AT& ~• OC. DAl<K Fll:D IVY ~1111 a: z (./') <( a: z 0 ,..--.. ~ / I © ~ • Al'l<ICANDAl&r FOOT HILL il£OOE 4 IN. POT& Ii'' oc. 4 IN. FOT& lo' li!)C. <( ....J 0... LL ~ ...J <{ I I I / \ CJRB_'__/ CARE)( 11J1Jl.lco.A (/310 RETENT!CJ/1 AREAS) w 0 0 '-1. I I I PARKING LOT I LANDSCAPE AREA ----. P Ai<l(ING LOT AREA OF 23, :i89 5f. I INCLUDES 1119 5f. OF LAND5CAPE / PROVIDED LANDSCAPE EXCEED& REG!JIRED MINIMUM OF (3%) 108 Sf. I '. I I -...._ / ', • 4 .. :. ' ; .. ,._,,, .. I r \ \ / I I 12.0' 12.0'-, C _____ ___{___ ' !,, JX TING TREE· TYPICAL 5 YHl'lOL. -----, . SE KE'f FOR 5PECIE5. TO BE REMOVED u~ ss ornER 1111sE NPTED TO BE T NSPLANTED ill QUEEN PALM&! OR RE AIN IN PLACE /NOTED 11/ITH 'R' J. BIO RETENTION AREA& PER CIVIL ENGINEER'S GR4DING PLAN&. SEE NOTE BELOIU, C """"" I / I 1. ,, / l --- /'--\c"..Ml-+-+-t--+-c-P-ct-+-. •· © ~ / --·-I / ...... \ ' . / ~'---~i '·-- 1-""1~.,4 l,T~-;'~----. •., -I (A\ \ FROP. Fll'f 5ERVICE7 WI EPC AND FIV I, I S89'33'25"E 333.91' I I.QI --1 '·-TU,: I ·~EXl&TNG I MEDIAN TO I I REMAIN ' !>1 J 0::: 0 <( 0 <( ~ 0::: <( -I I I I ' INTER& TION &IGHT/ LINE , (PLANT G HELD BACK PER/ STANDARD AJ I I I I I <] " JJ r r I ' EXl5Tll-l:l LAND5CAPE TO Ill: MAINTAD-El). TO ff .'1:RIR/5/S!/E[) AS NECESS/.Rr /II/Tll /1£111 TREES AS S/10/PI 4[)[)/TICJ/IAL S/1/il!f!S ,4!I[) GROilN[)COVER TO I/FILL Al/r !3ARE A'iEAS. PR/t'.ARr 6ROlll/[)COVER IS MrROrV/il!M f'ARV!fOLIIJ/1 /ION L!V/N(j GROIINXOVER DEca11'()SED GRANl!o • 3/8 HW, DEeERr c.oLD COLOR EXISTING TREE LEGEND TREES L OCA Ti:[) CJ/I AOJACENT Cir-SITE ARE4S ARE !NCLWE[) ·-· •, _ 1£1 £JOTANICAL NAME COM1CJV NAl1f ,.< ' ~ @, . t -·, Al<£CA5Tru1 ~INLH GUEN PALM • I ," 7 1 .:·,/ 'iJ: \ CA= """""' ., ., ~ I CUFANOF'SI& •N'V, """" ( ' ' 1 © ; -~-\= / ERYTHRINA CORAi. TREE \ ,, J \ . ' ' ' ,)·:. _ _-1-·"\@ ; Q.Jl:RCIJ& ILl:X IULY OA'< ALDER AfFROX Sil£ II X Ill 25 X 5 Ft-& IN. CAL 25 X 20 FT-& IN. CAL 6 X 20 Ft-I& IN. CAL ~ X 5 FT-I-2 IN.CAL 2!i X IS Ft· 10 IN. CAL 0... 0 <( <{ 0 _J OJ (./') (.J) 0 <( ...J z a: <( <{ ....J o_ I 0 SET ISSUE DATE INITIAL CD 31 JAN 13 PLAN CHECK 5 MAR 13 PLAN CHECK 14 MAR 13 RU! PLAN CHECK 21 MAR 13 SHEET: L.2 APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LCCA TION OF PLANTING AREAS. I I I -~ -·-~ --L __ .·· :: ,:_ _·· _· ----~· ----~ ---1--........~, ----·-----~ ------ PROPERTY LINE (TYPICAL 5 YHBOLJ LANDSCAPE PLANTING PLAN NORT~ 0 20 40 FT. I r'IIIIIIIIIIIIIIIIIIIIII I 1111111111111111111111""'-111111111111111111111111111111111111111111111 SCALE NEU/ PRIVET PLANTINGS TO REPLACE EXISTING ~-INTERSECTION 51GHT LINE BIO RETENTION AREAS TO BE LANDSCAPED /AS SHOUN! IN ACCORDANCE 11/ITH CA5QA STANDARD TC-32. &OIL AND BACK FILL PRE CIVIL EN::.INEER'S PLANS. TREES AND SHRUB& TO BE PROVIDED. THESE ARE REQUIRED TO BE IN FULL ll,IQFJ<I~ ORDER PRIOR TO OCCUPANCY, 1111TH PLANTINGS FULLY KNITTED IN AND COVERNG. UTILITY SCREENING NOTE: ALL UTILITIE& ARE TO BE SCREENED. DUE TO RELOCATION OF UTILITIES .L>J=TER PLAN APPROVAL, THE CONTRAcTOR SHALL CONTACT THE LANDSCAPE ARCHITECT PRIOR TO BEGINNING LAND5CAPE ll,IQFJ< 50 THAT THE LAND5CAPE ARCHITECT CAN REVIEW THE PROJECT UTILITY LOCATIONS AND REVISE PLAN5 ACCORDl~L Y TO FULLY 5CREEN ALL UTILITIES FROM VIEU/. SEE NOTE5 BELOW. /STANDARD 6, AT THESE ENTRIES! INTERSECTION SIGHT LINES FIRE HYDRANT PLANT&, II/HEN INSTALLED AND AT MATURITY, WILL BE POSITIONED TO AVOID OBSTRUCTION MOTORl&T51 VIEWS OF PEDE&TRIAN CROSSINGS, PRIVEU/AY&, ROADII/AYS AND OTHER VEHICULAR TRADE ll/AY5. AJ ON COLLECTOR STREETS AND LARGER, LAND5CAPE ELEMENTS OVER 3ei lNCHE5 IN HEIGHT rlt-t:LUDING PLANTING MEASURED AT MATURITY! A& MEASt:REP FROM ADJACENT STREET GRAPE ARE NOT PERMITTED AT 5ffil:ET CORNER5 UIITHIN A TRIANGULAR ZONE DRAU.N FROM TOO POINT&, 25 FEET OUTU/ARD FROM BEGINNING OF C~RVES. BJ AT MEDIUM TO HIGH USE DRIVEII/A'i'S, THE 30 INCH HEIGHT LIMITATION APPLIES AT DRIVEWAY& 25 FEET FRCM THE EDGE OF THE APRON OUTU/ARD ALONG THE CURB, THEN 45 DEGREES TOWARD& THE PROPERTY. CJ LAND5CAPE FEATURES (SHRUBS, TREES, FENCING, ETC.J &HALL BE &ELECTED TO ENSURE THAT NO Vl&UAL IMPAIRMENTS OR OBSTRUCTION& ARE LOCATED WITHIN THE CAL TRAN& SIGHT DISTANCE LINE&. DJ CAL TRAN5 SIGHT DISTANCE LINES HAVE A HORIZONTAL AND VERTICAL COMPONENT (PROFILE!. &!GHT UNE& ARE DETERMINED BY THE FROJECT CIVIL ENGINEER 'AS BUILT' DATE TITLE REVEWED BY: INS?ECTOR DATE --· ---------+---+--t----+---il ~E2ET• I CITY OF CARLSBAD I ~E,ETS I ~===;====:=========----_-_-_-_-_-_-_-_-_-_-_-_ ----=:====:===~====:===~ ~===='--'===::':P:=L:::'AN::':N:=ING::::::::::'::DIV::'::IS=:IOIII========:::.:'.....===~ PLANTING PLAN DATE NlflAL LAND. AR:Jl PALOMAR PLACE PALOMAR AIRPORT ROAD CARLSBAD, CALIFORNIA /-i;_.( \ '=r-et l..blt-'4-. ~""l,. /'? ------------+--+----+---+----; ~========~';=::::::::==:::::::::::;::==;-r=-,=,,=:-:::,,,~==:..,.=-,.=-=-==- I APPROVED> FlANNI-.G DATE I Dl'vN BY: PROJECT NO.• DRAWING NO.: REVISION DESCRIPTION DATE IWL'\L DATE INlflAL CHKD BY: 6DF 90-05! G) 471-~L QTY APPfOVAL OTHER APPFOVAL FEill BK: ~-----------------------------------------------------------------------------------------------------------------------------~ GENERAL NOTES -------------- A CCNTRACTOR iiHALL NOTIFY Ti-E ~&cAFE A~ITECT AT LEA5T 48 HOURS (Tiro~~ DAYS) PRIOR TO STARTI~ CONSm.JCTION. B. Cill-lER/DEVELOPER 5HALL PElst!ANENTI. Y AND Rll.L Y MAINTAIN ~D AREA5 WITHIN ADJACENT GENERAL UTILITr EA&EMENTS. C. AFFROYED 501L TESTI~ LAaORATORY e.lALL PE~ AGRICULTURAL AND StRUcTURAL 501L TESTS. 501LS TESTn~ FOR AGRICULTURAL 5UITA61Lllr 5HALL aE ACCC11Fl.15HEP Uf'Cl>l atlPLETION OF FINAL GRADING! PRIOR TO LAND&cAPE CONStRUcTION. -SEE 501L MAW6EMENT NOTES. D. CONTRACTOR 5HALL VERIFY EXISTING! &TATIC WATER PRE55URE AT EACH POINT OF ~TION PRIOR TO IN&TALLING! IRRIGATION 5Y5TEM. VERIFICATION &HALL aE MADE WITH Tl-IE CARl.56AD MUNICIPAL WATER DISTRICT. E. PROVIDE CONCRETE MO.II STRIP& aETU.EEN LAWN AND GRO.ND COVER. AND aETU.EEN LAU.N AND WALLS <HRE AFFLICA6LEJ. REFER TO STANDARD DETAILS REGARD!~ MOW STRIP&. F. LAND&cAPE iOC)f,j< 514ALL aE IN ACCORD.61-lCE WITU Clll', WATER PURVEYOR AND OTl-lER AFF'LICAaLE ~&GAPE REQUIREMENTS, LATEST EDITIONS. CONTRACTOR 15 RE5f'Cl>lS16LE FOR 6EW11~ FAMILIAR AND W1FL YING! WITU TUESE REQUIREMENTS. G. CCNTRACTOR iiHALL 06TAIN PE~IT5 REQUIRED TO W1FLETE LAND&cAPE !Mm)VEMENTS PRIOR TO &TART OF CONStRUcTION. 1-1. Cill-lERIDEVELOPER 5HALL oar AIN A RIGHT-Cf-WAY PE~IT OR ENCROACHMENT MAINTENANCE AND REMOVAL .AC:sREEHENT A5 DETE~INED BY Tl-IE c,rr PRIOR TO TUE CONSm.JCTION Cf ANY PRIVATE IMFROVEMENTS, INCLUDING! INSTALLATION Cf REQUIRED STREET TREES IN Tl-IE FUaLIC RIGHTS-Cf-WAY AND Cllr-i-lELD EA&EMENTS. PE~IT5 AND AGREEMENTS iiHALL aE REVIEII.ED AND AFFROVED ar Ti-IE c,rr. I. CONTRACTOR &HALL NOTIFY 'DIG ALERT' (I-Sln-221-2"00! TO LWT 48 HOURS PRIOR TO START Cf EXCAVATION IN FUaLIC RIGHT Cf WAY OR GENERAL UTILITr EA&EMENT. J. CONTRACTOR 5HALL PROVIDED ST~ WATER POLLUTION PREVENTION MWURES AND aEST MAW6EMENT PRACTICES IN ACCORDANCE WITH NFDE5, STANDARD URa-"J'-1 ST~ WATER MITIGATION FL-"J'-1 !5U5MF) ORDIN-"NCE, Cllr ORDINANCES, AND OTI-IER AFFLICA6LE CODES AND REQUIREMENTS. K. LANDSCAPE ltffOVEMENTS 5HALL aE W1FLETED AND AFFROVED BY TUE Cllr PRIOR TO Tl-IE 155U-"J'-ICE Cf OCCUF-"J'-ICY PE~ITS. L IRRIGATION A5-BUILT FLANS ARE REQUIRED TO 6E REVIEII.ED AND AFFROYED BY Tl-IE Cllr AND FINAL FL-"J'-15 WILL aE REaJIRED TO 6E AFFROYED AND SIGNED BY Ti-IE Cllr PRIOR TO RELEASE Cf SECURITIES. 5U6MITT AL Cf A5 BUILT FLANS &HALL aE A5 REQUIRED BY Tl-IE ~INEE~ AND FL-"J'-INI~ DEPARTMENTS. Tl-IE FINAL FLANS WILL aE PREPARED BY Ti-IE LANDSCAPE A~ITECT FRa-1 DIMENSIONED REDLINES TO aE PROVIDED BY TUE LANDSCAPE CONTRACTOR. SEE IRRIGATION 5U6MITTAL SPECIFICATION6 l.8.C FOR A5 BUILT REDLINE REQUIREMENTS. FINAL A5 BUILT FLANS &HALL 6E DRAFTED CLEAR!. r TO Ti-IE SATISFACTION Cf Ti-IE Cllr AND TUE FINAL FL-"J'-15 5HALL 6E SUBMITTED TO Tl-IE c,rr FOR TI-IEIR KEEF1t4 A5 BUILTS MAY aE PROVIDED ON BOND PAPER. SOIL MANAGEMENT PROVIDE 501L TEST Cf CHEMICAL AND AGRICULTURAL ANALYSIS ar AN INDEPENDENT AGRONOMIC 501LS TEST!~ LABORATORY. REPRESENTATIVE 501L 5A11FLES &HALL aE TAKEN IN Tl-IE FIELD AND A WRITTEN REPORT 5HALL aE PREPARED BY THE AGRONOMl&T AND &HALL INCLUDE RECOMl"ENDATION6 FOR 501L AMENDMENT& AND AFFLICATION RATES FOR 501L PREPARATION FERTILIZATION, FL-"NTI~ 13ACl<flLL MIX, 1-lYDRO MULCU SLURRY /A5 AFFLICAaLE! AND A POST MAINTENANCE 1'1:RTILIZATION F'R!'XiRAM. 501L ANALYSIS SHALL aE PROVIDED AFiER FINAL GRADING!, PRIOR TO START Cf LANDSCAPE CONStRUcTION. PROVIDE Tiro COFIE5 Cf THE ANAL Y&IS TO THE LAND&CAPE A~ITECT. PROVIDE ACTUAL 501L Al1:NDMENTS FER 501L ANAL Y515 RECOMMOOATION5. FOR 61DDI~ FURP05ES A551J1E Ti-IE APPLICATION Cf Tl-IE FOLLOWING! AMENDMl:"NTS AND FINl&U GRADI~, I~ LB&JIM!' Sf. AGRICULTURAL GYF&.11 2S LB&JIM!' Sf.12-12-12 FERTILIZER I~ LB&JIM!' Sf. 'GROJ.roLER FLUS UJ/ SULFER' 3 CU. YD5JIM!' Sf. NITRG1'1ED ORGANIC 501L AMENDMENT <FER SPECJ ROTOTILL IN THE TOP"' Cf 501L: Ti4ERE/lfTER FOR ALL Ai<EAS: RAKE AND Fll-E GRADE ALL PLANT!~ AREA5. MAINTAIN A MINIMUM 2% DRAINAGe AWAY lm1 ALL BUILD~ AND StRIJCTURES, AND &% WITUIN FIVE FEET OF BUILDING OR StRUcTURE. SMOOTH FINISH GRADES TO ELIMINATE FUDDLING AND &TANDll--1:. WATER. COORDINATE WITl4 OTUER TRADE& AND MAINTAIN DRAINAGE DURlt-1::i CONS tRUcTION. AFFL Y 501L LEACH!~ A5 ANALYSIS INDICATES PLANTING FIT& AND FL-"J'-ITERS SHALL aE BACK FILLED WITU AMENDED EXISTING! SITE 501L AND 1/3 !BY VOLIJ1E/ NITRG1'1ED ORGANIC 501L Al"&IDMENT. FERTILIZE TREES, SHRUBS AND GROUND COVERS AT TIME Cf FL-"NTING WITH ~ TABLET(&! FER SPECIFICATIONS AT THE FOLLOWING RA TES: FLAT MATERIAL -I (5 GRAli!TAaLET LINERS -2 (5 GRA!i! TAaLETS I GAL SIZE -I TA6LET IS GAL -S TABLETS S GAL SIZE -3 TA6LETS 2-4' BOX -& TAaLETS CITY SLOPE PLANTING NOTES SLOPES "°'' OR STEEPER REQUI~ EROSION CONTROL MWURES A5 SPECIFIED 1-EREIN 5HALL aE TREATED WITH ONE OR MORE Cf THE FOLLOWING! PLANTING! ST AND ARDS. AJ STANDARD ~ -COVER Cf/OP/ REINFORCED STRAW MAT: COVER CROf' SHALL 6E A SEED MIX TYFICALL r MADE IJF Cf QUICK GE~INATI~ AND FA5T COVERING! GRA55ES, CLOVERS AND/OR IIALD FLOUERS. SUBMIT THE SPECIFIC SEED MIX FOR Cllr AFFROYAL PRIOR TO AFFLICATION. Ti-IE COVER CROP 51-lAI.L aE AFFLIED AT A RATE AND MANNER SlfflCIENT TO PROVIDE W% COVERAGE WITHIN THIRTY !31?>! DAYS. rrFE Cf REn-fORCED STRAW MATTING! SHALL 6E AS AFFROYED BY Tl-IE Cllr AND STAKED TO Tl-IE SLOPE A5 REW1MENDED BY Ti4E MANl.fACTURER. REINFORCED STRAW MATTING SHALL aE REQUIRED UJI-IEN PLANTING OCCURS 6ETU.EEN Al.l'.iU5T IS AND APRIL I!;. THE COVER CROP AND /OR REINFORCED STRAW MAT &HALL 6E USED THE REMAINDER OF THE YEAR. 6/ STANDARD ".I -GROUND COVER, MINIMUM FLATTED SIZE ONE I-IJNDRED !!00%! PERCENT Cf THE AREA SHALL aE FL-"NTED WITH A GROUND COVER KNOU.N TO UAVE EXCELLENT 501L 61NDI~ CUARACTERISTICS (PLANTED FRa-1 A MINIIU1 SIZE OF FLATTED MATERIAL AND &FACED TO PROVIDE FULL COVERAGE WITHIN ONE YEAR!. CJ STANDARD "3 -LOW SHRUBS LOW SPREADING WOODY SHRl.l65 !FLAN1'ED FRa-1 A MINIM\11 Cf 2-3/-4 INCU LINERS! SHALL COVER A MINJMIJM Cf 5EVENTr (10%) FEFaNT OF Tl-IE SLOPE FACE /AT MATURE SIZE!. DJ STANDARD t-4 -TREES AND/OR LAR'.:!E 5i-lRl.l65 TREES AND/OR LAR'.:!E SHRl.l6& SHALL aE !PLANTED FROM MINIMi.111 GALLON CONTAINERS) AT A MINIMIJ1 RATE Cf ONE (I! PER Tiro I-IJNDRED !200) SQUARE FEET. SLOPES "°'' OR STEEPER AND: A) 3 FEET OR LESS IN VERTICAL 1-!EIGHT Al-0 ADJACENT TO RJBLIC WALKS OR STREETS REaJIRE AT A MINIMUM STANDARD• /COVER CROP OR EROSION CONTROL MATTING!>. 6! GREATER TH-"J'-13 FEET TO 8 FEET IN VERTICAL HEIGHT REaJIRE &TANDARDS, !EROSION CONTROL MATTING! iiHALL aE INSTALLED IN LIEU Cf A COVER CROP!, ".I, AND "3. C) IN EXCESS OF & FEET IN VERTICAL 1-lEIGHT REaJIRE STANDARDS~ /EROSION CONTROL MATTING! SHALL aE INSTALLED IN LIEU OF A COVER Cf/OP), ".I, "3 AND •4. GRADED AREAS FLATTER TH-"J'-16,1 REQUIRE STANDARD , /COVER CROP! WITH TEMPORARY IRRIGATION UJHl:N Ti-lEY HAVE ONE OR MORE OF THE FOLLOW!~ CONDITIONS: A) SUEET GRADED FADS NOT SCi-lEDULED FOR IMPROVEMENTS WITHIN 6 MONTHS Cf W1FLETION Cf ROUGH GRADlt4 6) A POTENTIAL EROSION PROBLEM A5 DETE~INED ar THE Cllr. C) IDENTIFIED er Tl-IE Cllr A5 HIGUL Y Vl516LE TO THE FUaLIC OR UAVE SPECIAL CONDITIONS THAT WARRANT 1111EDIATE TREA111ENT. Tl-IE A60YE STAINDARDS WILL aE SPECIFIED AND SITED ON ~&GAPE CONStRIJCTION FL-"J'-15 AND IMPLEMENTED Uf'Cl>l LANDSCAPE ro-l&mJCTION. TEMPORARY EROSION CONTROL LANDSCAPE 22. ON ALL SLOPES 3, I AND STEEPER Tl-IE FOLLOWING REQUIREMENTS SHALL aE 111'1..EMENTED PRIOR TO ACCEPTANCE BY TI-IE LOCAL INSPECTOR: a! GRO.ND COVER iiHALL aE PLANTED AT TU.EL YE (12! INCHES ON CENTER SPACING, AND b! FlaER ROLLS SHALL 6E INSTALLED AL® FACE Cf SLOPES AND TOE Cf SLOPES IN ACCORD-"J'-ICE WITH MANIJ=ACTIJRER'5 REW1MENDATION AND LOCAL REQUIREMENTS. 22. SLOPE FL-"J'-ITING SHALL ACUIEYE EFFECTIVE 501L COVERAGE IN ACCORDANCE WITU THE LOCAL GRADING ORDINANCE PRIOR TO FINISI-IED GRADE AF'FROVAL. IF EFFECTIVE 501L COVERAGE 15 NOT ACUIEYED IN THE REQUIRED TIME FRAME, THEN Ti-IE CONTRACTOR 5HALL 111'1..EMENT THE ADDITIONAL EROSION CONTROL MEASURES NOTED aELOW. EROSION CONTROL MEASURES SHALL 6E: a) FlaER MATRIX AFFLICATION !STAalLIZED OR BONDED!, OR b! EROSION CONTROL B!.PN<ETS !STRAW OR COCONUT FlaER.I, OR c! COMPOSTED LANDSCAPE MULCU (2-INCU DEPTH MINJ AND l-lYDRCl1ULCU + TACKIFIER, AND/OR d) GROLND COVER FL-"NTI~ AND FIBER ROLLS IN ADDITION TO ABOVE MWURES. PLANTING NOTES ---------------------------------------- L Tl-IE PLANTING FL-"J'-1 IS Dl~TIC AND 5HALL 6E USED A5 A GUIDE FOR SETTING OUT PLANTS. PRIOR TO PLANTING, THE ~SCAPE ARCl-llTECT iiHALL aE CONT ACTED TO AFFROVE ALL PLANT LOCATIONS AND DIRECT ADJIJ5111:NTS. 2. PLANT MATERIALS SHALL~ TO NURSl:~'5 STAINDARDS FOR SIZE AND HEAL Tl-I. ALL PLANTS ARE 5U6JECT TO REJECTION ar THE ~SCAPE A~ITECT IF 5U6&TANDARD IN SIZE, Q\JALITr OR HEAL TH. 3. PLANT cot.M'S ARE FOR Tl-IE CONVENIENCE Cf CONTRACTOR ONLY. CONTRACTOR 15 RE5f'Cl>lSIBLE FOR ALL PLANTS 5HOU.N ON FLAN. 4. IRRIGATION 5Y5T815HALL 6E RJLL Y OPERATIONAL AND ALL PLANTING! AREA5 THOROUGHLY SOAKED PRIOR 10 FL-"J'-ITlt-l::i. S. ~SCAPE CONTRACTOR 5HALL MAINTAIN A MINIMUl1 Cf 2% DRAINAGE AWAY FROM ALL BUILDING!S AND FINISH GRADES 5MOOTI-IED TO ELIMINATE FUDDLING! OR STANDING! WATER. CONTRACTOR &HALL COORDINATE WITH OT14ER TRADES AND MAINTAIN DRAINAGE DUR!~ CON51'RUCTION 6. REMOVE ALL EXISTlt-1:i VEGETATION /EXCEPT INDIVIDUAL FL-"J'-ITS TO REMAIN FER FLAN AND A5 IDENTIFIED BY LAND&CAPE ARCl-llTECTJ TRA5H, CLIPPINGS AND OTHER DEBRIS IN FLANTI~ AREA&. ERADICATE 6E~A GRA55 AND NOXIOUS II.EEDS A5 FOLL~ A Uf'Cl>l INSTALLATION Cf IRRIGATION SYSTEM, CUT II.EEDS AND AFFL r AN ALL PURPOSE FERTILIZER, 5UCU A5 2~ L6&/AC Cf 1"·6-8 AND IRRIGATE FOR 11llO TO FOUR II.EEKS. a U!-lEN II.EEDS AND GRASSES ARE AFFROXIMATEL Y ONE TO 111.0 INCUES IN 141:IGHT, &FRAY WITH A NON SELECTIVE HERJ3ICIDE. C. PLANT A5 SPECIFIED. 7. PRIOR TO START Cf FL-"NTI~ llt)RK. FL-"NTING AREA& 5HALL 6E FREE Cf ll.EEDS AND 5UlsfACE ROCK5, AND CONTRACTOR 5HALL E&TABLISH FINISI-IED GRADES. /lfTER W1FLETION Cf FL-"J'-ITING llt)RK. CONTRACTOR &HALL FINE GRADE ALL FL-"J'-ITING! AREAS AND REMOVE SIMACE ROCKS, CLODS AND DEBRIS. &. PROVIDE 501L MANAGEMENT FER NOTES ~ VERIFY TREE FIT DRAINAGE WITH 2-4 HOUR WATER FILL TE&T PRIOR TO FL-"J'-1Tlt4 ALL BOXED TREES NOT DRAINING ARE TO UAVE A 4' DIAl1:TER AUGER HOLE DRILLED THROUGH ANY HARDPAN OR W1FACTED EARTH A5 REaJIRED TO PROVIDE DRAINAGE. 10. FL-"J'-ITING FITS 5HALL 6E 11JJICE Ti4E CONTAINER WIDTH AND OF EQUAL DEPTH. II. FLANTlt-1::i FITS AND PLANTERS 5HALL aE BACK FILLED WITH EXISTING! SITE 501L A'IID 1/3 (BY VOLUME) NITRIFIED 501L CONDITIONER MIX 12. DOUaLE STAJ<E IS GALLON AND 2-4' BOX TREES. GUY LAFl:,ER TREES A5 NECESSARY. CONTRACTOR SHALL aE RESFCNSl6LE FOR TREE STABILITY FOR Ti-IE LOO TU Cf THE GUARANTEE. 13. LOCATE STREET TREES " INCHES INSIDE RIGUT Cf WAY, AL~ WITH ADJACENT FROFERTIES), GENERALLY EQUALLY SFACED AND IN ALIGNMENT WITH TREE ON OFFOSITE SIDE Cf STREET (EXCEPT A5 ADJUSTED FOR UTILITr ca-FLICTS!. 14. NOTE RELATIONSHIP TO PLANTINGS TO IRRIGATION, PARTICULAR!. Y IN LINEAR CCI-FIGURATIONS. COORDINATE HRE FLANTI~ AND IRRIGATION HEAD SFAClt-1::i CORRE5f'Cl>lD TO MAINTAIN UNI~ SFACll--1:. aETU.EEN FL-"J'-ITS AS II.ELL A5 FL-"J'-ITINGS AND IRRIGATION. IS. CONTAINER PLANTS SHALL NOT 6E PLACED llJITHIN 2 FT. Cf 5FRA r i-lEAD, -4 FT. Cf LA~ RADIUS ROTOR, UNLESS OTHERWISE INDICATED ON PLAN. '"· SHRl.l65 4 TREES &HALL aE UNDER PLANTED WITH GROLND COVER OR HYDROSEED A5 5HOWN ar ADJACENT SYMBOL 11. PROVIDE THREE(':,') IN. DEPTH &HREDDED 6Alii< MULCU !NO RECYCLED GREEN OR CON&mJCTION WA5TE-SEE &FECIFICATION) IN ALL NON-TUl.f PLANTING! AREA& LESS THAN 3:1 IN SLOPE. 5U6MIT &AMPLE TO LANDSCAPE A~ITECT AND LOCAL INSPECTOR FOR AFFROVAL PRIOR TO BULK DELIVERY. HOLD 6Alii< MULCU I FT. FROM EX!ERIOR WALL Cf StRUcTURES, FROVIDI~ AA'<ED BARE EARTH IN THIS Ai<EA (FOR FlRE PROTECTION). FOR DRIP AREA5 ,6J() AREA5 INDICATED WITU GRAVEL MULCU-PROVIDE MINIMLIM DEPTH TO COVER 501L CCMFLETEL r, OR PER FLAN LEGEND, IU-IICHEVER IS GREATER. 5U6MIT 5Al1FLE TO LANDSCAPE A~ITECT FOR AFFROYAL PRIOR 10 BULK DELIVERY. 10. CONTRACTOR SHALL PROVIDE A 11.EED FREE LANDSCAFE THROUGH Tl-IE E5TA6Ll5H1ENT MAINTEN.61-lCE FERIOD. PRE-~ UERJ51CIDE MAY aE AFFLIED TO ALL FLANTll--1:. AREA& PRIOR TO SFREADll--1:. MULCH. HER61CIDES SllALL aE USED IN ACCORDANCE WITH AFFLICA6LE RI.ILES AND REGULATION&. la PROVIDE POST FLANTll--1:. FERTILIZATION SHALL 6E PEl<fO!ffD AT~ AND 1& DAYS AFTER FL-"NTING. 20. PROVIDE EST A6L15HMENT MAINTENANCE Cf ALL LAND&cAPE FOR NINErr !~! DAYS AFTER INITIAL ACCEPTANCE Cf CCMFLETION. KEEF ALL AREA& CLEAN, WATERED AND 11.EED-Asff. ALL DEAD OR DYING PLANTS SHALL aE REPLACED DURING! THE MAINTEN.61-lCE PERIOD. SEE MAINTEN-"J'-ICE NOTES 2l CONTRACTOR 5HALL GUARANTEE FLAIIIT LONGEVITr FOR ONE YEAR. ADDITIONAL PLANTING NOTES EXISTING LANDSCAPE NOTE EXISTlt-1::i TREES 5HOU.N WILL REMAIN. ANY AREA& BARE OR DISTURaED BY CONSmJCTION WILL aE REPAIRED WITH NEW LANDSCAFll--1:. TO MATCI-I. EXISTING TREE PROTECTION Ti4E FOLLOWING PROTECTION FOR EXISTll--1:. TREES TO REMAIN ON SITE WILL aE PROVIDED, I-A BRIIJHT YELLOW OR ORA~ TEMPORARY FENCE WILL aE PLACED AROUt() EXISTING TREES AT THE DRIP LINE. 2-STOCKPILING!, TOPSOIL DISTURBANCE, CONStRIJCTION MATERIAL &TORAGE, VEUICLE USE, FOOT TRAl'flC, AND STORAGE Cf ANY KIND IS FROHl611ED WITHIN THE Df<IF LINE OF EXISTlt-1::i TREES ON SITE. 3-ROOT SYSTEMS Cf EXIST!~ TREES ON SITE WILL aE PROTECTED FRa-1 FLOODING!, EROSION, CUEMICAL SFILLS, AND EXCESSIVE LI.ETTI~ AND DRYING! Dl.lf<ING DE-WATERlt4 4-THE EXl&Tlms GRADE WILL aE MAINTAINED WITHIN THE DRIP LINE Cf EXISTING! TREES ON SITE. &-ROOTS Cf EXISTll--1:. TREES ON SITE IIALL aE CUT APPROXIMATELY" INCHES BACK FRa-1 NEW CONSTRI.ICTION AND ALL CUTS WILL 6E SEALED WITH WOOD FAINT A5 MANI.FACTURES BY FL!Nn(OTE OR AFFROYED EQUAL. "°" MAINTAIN AND DoctHENT A TREE WATERlt-1::i &ci-lEDULE DURll--1:. CONSmJCTION. 1-ALL DAMAGED TREES WILL 6E REPLACED WITH ONE Cf EQUAL OR GREATER SIZE. TREE SETBACK MAINTAIN TUE FOLLOWI~ TREE SETBACKS (1-lORIZONTAL lm1 CENTER Cf TRIOO -3 FT. FRa-1 FROFERrr LINE -S FT. FRa-1 UTILITr Sm.JCTURES, INCLUDING LNDER GROUND -kll FT. FRa-1 DRAINAGE AND SEU.ER, A60\IE AND IMPER GROUND • S FT. FRa-1 FIRE UYDRANTS -kll FT. FRa-1 STREETI.IGHTS -kll FT. FROM DRIVEWAYS -2S FT. lm'I STREET INTERSl:CTIONS <SEE 51GUT Vl5161L1Tr LINES! -2/D FT. lm'I TRAl'flC SIIJNALS /STOP LIGHTS! -VERTICAL LIMB CLEARANCE Cf IS FT. OVER STREETS, kll FEET Cf OVER BIKE AND FEDESTRl-"J'-1 AREA5. VERIFY MINIMtt1 SEPARATION DIST-"J'-ICE IN FIELD PRIOR TO FL-"NTING. Uf'Cl>l lDENTFICATION OF CC!-FLICT, CONTACT LANDSCAPE A~ITECT AND ADJUST TREE LOCATION A5 DIRECTED. ROOT BARRIER REQUIREMENT PROVIDE DEEP J.roT 6ARRIERS AT PERIMETER PAVING!, CURB, StRIJCTURE OR FOUNDATION Cf ALL FLANTI~ AREA5 CONTAINING! TREES WITHIN 6 FEET Cf SIDEWALK, SmJCTURE, CURB OR FOUNDATION. BARRIERS SHALL aE 24 INCHES IN DEPTI-I. L~TH SHALL EQUAL 12 FEET PER PROTECTED EDGE. DO NOT WRAP INDIVIDUAL J.roTl3ALLS. PALM TREES ARE EXCEPTED. <SEE DETAIL! EROSION CONTROL FABRIC REQUIREMENT PROVIDE 501L STAalLIZATION FAaRIC, PER MANI.FACTURER'S SPECIFICATION, ON ALL ~SCAFED SLOPES Cf 3:1 OR STEEPER GRADIENT. SEE COI.INTr LAND&CAPE REQUIREMENTS AND cct1FL r. DRAINAGE BEST MANAGEMENT PRACTICES NO IRRIGATION RI.IN Cff 5HALL DRAIN Cff SITE INTO Ti-IE FUaLIC RIGHT OF WAY, STREETS, DRIVES OR ALLEYS. NO CONNECTION SHALL aE MADE TO ANY ST~ WA'IER 5EUER SYSTEM WITHOUT FROFER FBMF'S. ALL ROOF DISCHAR'.:!E TO aE TO SUFifACE DRAINAGE. REFER TO ST~ WATER POLLUTION FREYENTION FL-"J'-1 MAINTENANCE NOTE ALL REQUIRED LANDSCAPE AREA& SUALL aE MAINTAINED ar THE FROFERrr OWNER. THE LANDSCAPE AREA& &HALL 6E MAINTAINED FREE Cf DEBRIS AND LITTER AND ALL PLANT MATERIAL SHALL aE MAINTAINED IN HEALTHY CONDITION. DISEASED Cf DEAD PLANT MATERIAL SHALL aE SATISFACTORILY TREATED OR REPLACED FER Ti-IE CONDITIONS OF Tl-IE f'EJ;3'11T. AHLES LANDSCAPE ARCHITECTURE INC. P.O. Box 1503 Rancho Santa Fe, CA 92007 858-756-8963 PROJECT NO.: w 0 <( _J (l_ 0: (j) <( z <( .....J ~ CL w 0 0... <( 0 _J (j) 0 <( z <( .....J (l_ I SET ISSUE 1218 ~ z a: 0 LL ::J <( 0 o" <( en (/) _J a: <( 0 INITIAL CD 31 JAN 13 PLAN CHECK 5 MAR 13 PLAN C~ECK 14 MAR 13 RUJ PLAN CHECK 21 MAR 13 SHEET: L.3 APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LCCA TION OF PLANTING AREAS. 'AS BUILT' DATE TrrLE REVEWED BY: INSPECTOR DATE l---+----+--------------j-----j---j---+-----1 I 3ET• I I---+---+----------------+-----,f----+----+-----1 CITY OF CARLSBAD I Sf-E,ETS I PLANNING DIVISION ------ ·-~-------i--+-----i 1----+----+--------------j----+-----I-------- LANDSCAPE NOTE& PALOMAR PLACE PALOMAR AIRPORT ROAD CARLSBAD, CALIFORNIA ~------- I-----+----+-----~---_-_------==---= ___ ==_ .. =_=--~-==:-_=:-_=:-_=:-_=:-=-=:+-_=:-_=::=:-_=:--+=:-_=:-_=:-_=:------I= ~I AP_P_RO_VED_•_1:iJ_-~PI.AN~\=NING=&r--_~_L_.,;tt ____ ~_D_-A~_-'_<'>_~ OWN BY: PROJECT NO.• DRAWING NO.• ~~: &DP ':10-0!:i/C:i) 411-!:iL DA TE INlflAL LAND. AFCH REVISION DESCRIPTION DA TE lfJTV\L DA TE INITIAL CITY APPfOIAL ornrn APPR'.lVAL SOIL PREFARA710N AND FINISH GRADING FART I • GENERAL I.I DE5CRiFTION A. 11.1:)Fl( INCLUDED, PREFARATICl-1 OF SUisfACE STRATA OF SOIL FOR Fl.ANTING INCLUP:NG, illJT NOT NECESSARIL T LIMITED TO, I. TOPSOIL PLACEMENT, 2. 501L5 TE5TING, 3. FLACEMENT AND INCORFORATICl-1 OF SOIL AMENDMENTS, 4. FINISH "'RAPING, ;, ANT INCIDENTAL ll/Orl< NOT 5HOIIJ,I OR SPECIFIED IIIHICH CAN REA50NA6L T 6E :NFERRED A5 FART OF ll/Orl<. 6. RELATEDII.OFl<, Fl.ANTING TREES, SHRU66 AND GROUND COYER 12 5\IBMITT Al.5 TEST RESULTS DELIVERY STATEMENTS 13 QU.\LITY ASSURANCE A 11.1:)Fl( SHALL 6E FE!sfORMED FER 6E51 5TANDARD5 OF PRACTICE RELATING TO VARIOUS 7RADE5 i.NDER Ca-lTlf!JOUS SUPERVISION OF COMPETENT FOREMAN, CAPABLE OF INTERPRETING DRAWINGS AND 5PECIFICATIONS, 6. HER61CIDE APPLICATOR &HALL 6E LICENSED 6T STATE OF CALIFO!iNIA 1.4 DELlvERT, 5TORAGE AND HANDLINc!A lllOFl< SHALL 6E FE>fORMED FER 6EST &TANDARDS OF A. Ca-lTAINER5 SHALL 6E UNOPENED AT DELlvERY AND RESPECTIYE LAl'lELS SHALL &HOW CONTENT&. 6. &TORE CONTAINERS Off THE GROIW AND PROTECT FROM THE llfATHER I.S PROJECT SITE CONDITIONS A. WHEN EXISTING /STOCKPILED! SOIL 15 AVAILABLE CONTRACTOR &HALL vERIFT Tri!: CIJANTITT, LOCATION AND IIIHEN 501L CAN 6E MOvED INTO THE PLANT:NG AREA &TOCKFILED SOIL 15 TO MEET CONDITIONS DE5CR16ED IN SECTICl-1 ON MATERIAL &TANDARD56. NO SOIL SHALL 6E MOVED INTO AREA& WHEN EITHER THE SOIL OR EXl5TING GRADE IS TOO u.ET OR DRY, OR IIIHEN DELETERIOJS MATERIAL& ARE PRESENT. FART l • PRODIJCT5 2.1 TOPSOIL A SOURCE, 0ff-51TE 60RROW TAKEN FROM &OURCE ACCEPTA6LE TO LAND5CAPE ARCHITECT. 6. ACID-ALKALINE RANGE, pH bf!) TO 1f!) C. FREE OF PE&TS, FE&T LARVAE AND MATTER TOXIC TO PLANT&. D. PERCENT OF ORGANIC HATTER, 2% MINIMU/1 E MAXIMUM 0% 6T VOLUME 5LAG, CINDER$, &TONES OR OTHER EXTRANEOU5 MATERIAL OVER 112' DIAJ-ETER F. FREE OF NOXIOU5 11.EED 5EED, PATHOGENIC VIRUSES, HER61CIDE5, OR CHEMICAL& THAT INH1611 GROWTH. C.. TE5T5 AND SAMFLING OF TOP&OIL, I. PROVIDE SOIL 5AMPLING FROM TJ.IRicE LOCATICl-15 AND 5\IBMIT TO CERTIFIED AGRONOMIC SOIL TE&TING LA60RATORT. 5U6HIT LA60RATORT TO PROVIDE TE5TING TO CITY FOR APPROVAL FRIOR TO TE5TING. 2. TEST&, ORGANIC MATTER, NUTRIENT ANAL Y515, TEXTURAL ANAL Y515 AND SALINITY TEST. PROl1DE TEST Rlc5ULTS AND AMENDMENT RlcCOMMENDATIONS 6Y TE5TING LA6 TO LAND5CAPE ARCHITECT AND CIT'i ffiOR TO AMENDMENT DELIVERY. CITY SHALL APPROVE TE&TING LA6. AND RECOMMENDATIONS PRIOR TO AMENDMENT DELIYERT. PLANTINci TREES, 5HRU65 AND GRCI.ND COVER PART I • GENERAL I.I DE5CRIPTICl-l A lllOFl< INCLUDED, PROVIDE ALL LA60R, MATERIALS AND ECIJIPMENT REGIUIRED TO COMFI.ETE 11.1:)Fl( ON DRAWINGS, COMPLETE IN Fl.ACE AND APPROVED, INCLUDING BT NOT NECESSARIL T LIMITED TO, I. FURCHASE OF PLANTS 2. ALL FLPNTIIG, INCLUDING GROUND COvER 3. INSPECTION AND CERTIFICATICl-1 12 CIJALITY ASSURANCE PE"1vRM IN ACCORDANCE WITH 6E51 STANDAl<PS OF PRACTICE RELATING 10 VARIOU5 TRADES UNDER CONTINUOU5 SUPERVISION OF COMPETENT FOREMA~. CAPABLE OF INTERPRETING DRA111Nci5 AND 5PECIF•CATIONS. 13 EXISTING SITE CONDITION& A ffiOR TO EXCAVATION OR PLACING OF STAKE&, LOCATE ALL ELECTFJC CA6LE5, CONDUITS, SPRINKLER VALVES, UTILITY LINE5 50 THAT PRECAUTIONS MAY 6E TAKEN NOT TO DAMAGE SUCH IMPROVEMENT&. IN EVENT OF CONFLICT BETu.EEN ~JCH LINES AND PLANT LOCATICl-1&, NOTIPr LAND5CAPE ARCHITECT. FAILURE TO FOLLOW THI& PROCEDURE FLACES UPOO CONTRACTOR THE RE11PONSl61LIT'i FOR MAKING PNT AND ALL REPAIR$ FOR DAMAGE RESULTING FROM lllJFl< HEREUNDER 6. vERFICATICl-1 OF DIMENSICl-15, ALL 5CALED DIMENS!Cl-1& ARE APPROXIMATE. 6EFORE PROCEEDING, CAREFULLY CHECK AND YERIFY ALL DIMENSIONS A~D CIJANTi-lE& AND IMMEDIATEL T INFORM LAND5CAFE ARCHITECT OF ANT Dl5CREPANCl 6ETII.EEN DRAWINGS, SPECIFICATION AND ACTUAL CONDITIONS. PERFORM NO ll/0'1( IN ANT AREA WHERE THERE 15 SUCH A DISCREPANCY UNTIL APPROVAL FOR &AME HAS 6EEN t;IVEN er LANDSCAPE ARCHITECT. l4 SCHEDUUNG I SEQJENCING A t,FTER SOIL HAS 6EEN PREPARED PER SOIL PREFARATICl-l SPEC .. IRRIGATICl-15T5TEM 15 NSTALLED AND CONDITIONS ARE FAVORA6LE TO PLANT, REG!JEST APPROVAL TO Fl.ANT. 6. IRRIGATIOO AND PLANTING MAY BY DONE CONCURRENTLY, HO\i.EVER, PI.AN71NG ll/Orl< MAT NOT &TART IN ANT SECTION PRIOR TO INSPECTICl-1 AND APPROVAi. OF IRRIGATIOO 11.1:)Fl<_ I.& SU66Tl1\JTIONS NO SU65111\JTIONS FROM SPECIFIED FLPNT MATERIALS WILL 6E PERMITTED U~LESS SU6STl1\JTE MATERIALS ARE APPROVED IN ADVANCE 6T LAND5CAPE ARCHITECT AND THE CITY, AND SU66Tl1\JTIONS ARE MADE AT NO ADDITIONAL CHARGE TO OIINER IF ACCEPTED SU66Tl1\JTES ARE OF LESS VALvE THAN THOSE INDICATED OR SPECIFIED, CON7RACT PRICE WILL llE ADJU5TED IN ACCORDANCE WITH PROVl&la-lS OF Ca-lTRACT. lb SU6HITTALS A FURNl5H &OURCE OF MATERIAL& IF F;lcQUE&TED 6T OWNER OR LAND5CAFE ARCHITECT 6. IN ADDITICl-1 TO ANT OTHER CERTIFICATES SPECFIED, FURNISH A CERTIF1CATE WITH EACH DELIVERY OF BULK MATERIAL STATING SOURCE, CIJANTITY, TYPE OF MATERIAL, AND TJ.IAT MATERIAL CONFORM& TO 5PECIFICATICN 5U6MIT CERTIFICATES ffiOR TO &TART OF MAINTENANCE PERIOD. I 1 GUARPNTEE AND REPLACEMENT ALL PLPNTS SHALL BE GUARA~TEED FOR PERIOD S?ECIFIED IN FI.PNTING NOTES. ANT Fl.ANT NOT GROWING PROPERLY DURING THIS PERIOD SHALL 6E REPLACED WITHIN SEvEN (1) DAYS OF 11.RITTEN NOTICE. GUAR#ITEE MAT 6E EXTENDED IN CASES F FI.PNTS ARE SLOW TO E5TABLl5H. IF CONTRACTOR FAIL& TO MAKE REPLACEMENTS ]1!1-ilN TIMI: LIMIT, OWNER MAT REFI.ACE THEM AT Cct.TRACTOR'S EXPENSE. PART 1 • PRODUCTS 2.! PLPNT CIJANTITIES AND TYFES FURNISH PLPNT MATERIALS IN G!J.ANTITIES AND SPACING SHOIIJ,I, OR NOTED FORE~ LOCATICl-1, OF 5PECIE&, KIND, SIZE, ETC. AS 5'1t1130LIZED AND DESCRll'lED IN PLANT LEGE~D. 1.1 PLPNT MATERIAL 5TANDARD5. A NOMENCLATURE, FLAN! NAMES LISTED IN Fl.ANT LEGEND CONFORM TO 'STANDARD PLANT NAMES' E5TA6LISHED BY AMERICAN COMMl11EE ON HORTIOULTURAL NOMENCLATURE, FOR NA'1ES NOT COVERED THER!clN FOLLOW LOCAL NURSERY CUSTOM. CALIFORNIA NATlvE FLAN! SPECIES PER 'JEPSCl-1 MPNUAL'. 11 SOIL CONDITIONER!, A PEAT, CANACIAN FEAT MOSS El. HER61CIDES, AS REGIUIRED UPON LANDSCAPE ARCHITECT'S APPROVAL. C. FERTILIZER I. PRE PLANTING FERTILIZER SHALL 6E LONG LASTING, CONTROLLED RELEASE, UNIFORM, FREE FLOWING 5UITA6LE FOR APFI.ICATION WITH APPROYED ECIJIPMENT AND SHALL CONTAIN THE FOLLOWING MINIMUM AVAILABLE PERCENTAGES BT !LEIGHT OF PLANT FOOD, FOR LAUN AREAS, N-F-K RATIO AS REGIUIREP FROM SOIL REPORT FOR 5HRU6 AREA&, N-P-K RATIO AS REGIUIRED FROM SOIL RlcPORT. 2. P05T PLPNTING FERTILIZER SHALL 6E OR6PNIC 6ASE, NON illJRNING, SLOW RELEA&E FREE R.OI.IIING, SUITAl3LE FOR APPLICATION WITH APPROvED EOOIPMENT WITH THE FOLLOW:NG MINIMUM AVAILA6LE PERCENTAGES OF llflGHT OF PLANT FOOD WITH TRACE MINERALS OF 'l\ IRON AND 3% $JLFJR, FOR LAUN AND 5HRU6 AREA$, N-P-K RATIO OF 14-1-3 3. PLANTING TA6LETS SHALL 6E TIGHTLY CO~PRESSED CHIF TYPE COMMERCIAL PLANT TA6LETS WITH THE FOLLOWING AvAILA6LE PERCENTAGES OF llflGHT OF PLANT FOOD, FOR 21 GRAM TABLETS, N-F-K RATIO OF 20-lil-5 FOR!, OR 1 GRAM TA6LET5, N-F-K RATIO OF 12-8-8. D. Oi<i,ANIC SOIL AMENDMENT&, DERIYED FROM REDWOOD OR FIR BAFl<, WITH SEYERAL GRADIENT DEGREES OF 6REl>J<DOIIJ,I, NON IONIC 11.ETTING AGENT, 51A61LIZED WITH NITROGEN i il.&%! A5 FOLLOWS, I. &ALINITY, SATURATION EXTRACT CONDUCTIVITY (eCE)NOT TO EXCEED I.lo AT 2, DEGREES CENT•GRADE. 2. 01<1,ANIC CONTENT, MINIMUM ~0% BT llflGHT. 3. pH, :i.& TO bf!). 4. Ca-lTAINING NO SLUDGE OR ANIMAL MANURE. E. MINERALS, I. S~IL SULFUR I&! SHALL 6E ELEMENTAL SULFUR(~~.&%! MINIMUM. 2. FERROUS SULFATE SHALL 6E PELTED OR GRA~AR FORM Ca-lTAINING NOT LESS THAN 18% METALLIC IRON. MATERIAL SHALL CONFORM TO THE AGRICUL 1\JRAL CODE OF THE STATE OF CALIFC;.:NIA 3. AGRICULTURAL GYPSUM <Ca504-2H20! SHALL 6E COMMERCIALLY FROCESSED WITH MINIMUM 80% GRADE CONTAINING 14% MINIMUM COM61NED SULFUR 4. LR1E (CaCO,! SHALL BE CALCIUM CARBONATES LIME. F. SOIL FENETRPNT, 'SARVON' BRAND. G. WATE~ I 50JRCE, IRRIClATICl-1 5TSTEH F.0.C. FART 3 • EXECUTION 3.1 INSPECTION A EYJ/'IINE GRADE TO RECElvE SOIL PREPARATION 10 ASSURE ll/Orl< OF OTHER TRADES HAS 6EEN COMPLETED. 6. VERIFY GRADE WITH LAND5CAFE ARCHITECT PRIOR 10 6EGINNIN~ SOIL PERFETRATICl-1 C. NO SOIL PREPARAT1Cl-l 5HALL 6E PE"1'CRMED UNTIL ALL STRUCTURES AND WALL$ AND CONSTl<OCTION ITEMS (INCLUDING HAINS AND DRAINAGE LINES! HAVE BEEN INSTALLED. D. THE 51TE SHALL 6E FREE OF llfEDS, TRASH AND DELETERIOUS MATERIALS PRIOR TO &oil PREPARATION. E. VERIFY THAT PLANTS TO REMAIN HAVE BEEN Lt-lDISTUR6ED. F. DO NOT FROCEED ~ITH SOIL PREPARATION JNTIL UN5ATl5FACTORT CONDITIONS ARE CORRECTED. B. CONDITION, 5'i1111ETRICAL, T'iFICAL FOR VARIETY AND SPECIES, 50\JND, HEALTHY, Vlc;QROUS, FREE OF DISEASE, INSECT FEST& OR EGGS, HAVING HEAL THY, NORMAL ROOT 5T5TEH5, l!ELL FITTING CONTAINER$ illJT NOT 10 POINT OF l'lEING ROOT 60UND. DO NOT PRUNE PRIOR TO DELIVERY. IN NO CASE SHALL TREES 6E !OFFED 6EFORE DELlvERY. C. DR1EN510N5, MEASURE HEIGHT AND SPREAD OF Fl.ANT MATERIAL WITH BRANCHES IN NORMAL POSITICN MEA5URE TREE CALIPER 2'·rll' A60YE GRADE. PROVIDE ALL PLANTS AT MINR1uM DIMENSION5 INDICATED ON PLANS, ll/,IERE CALIPER OR OTHER DIMENSICl-15 OF ANY PLA~T MATERIALS ARE OMlmD FROM PLANT LEGEND, IT SHALL 6E AvERAGE STOCK FOR TYPE LISTED. D. IN5PECTION&, ALL PLANT MATERIALS ARE SUBJECT TO IN5PECTION AND APPROVAL BEFORE PLANTING. ALL Fl.ANTS SUPPLIE5 TO PROJECT CWHETHER PLPNTED OR NOT! ARE SUBJECT TO RlcJECTICl-1. E. PLANT LIST, AS INDICATED ON Fl.ANTING FLAN F. SIZES OF PLANT5l PER PLANT LEGEND. CONTAINER STOCK ii,,, AND lo GALLON! SHALE HAvE l'lEEN GROUN IN CONTAINER!, FOR TIME SUFFICIENT TO DEVELOP ROOT GROWTH SUFFICIENT TO HOLD SOIL 6ALL TOGETHER TO SIDE AND BOTTOM OF CONTAINER IN IIIHICH IT WAS DELlvERED. r;, PLANTS NOT APPROvED, REMOVE FROM SITE IMMEDIATELY AND REFI.ACE WITH SUITA6LE FLPNT5. LANDSCAPE ARCHITECT HAT REJECT ENTIR!c LOT OF PLANTS REPRE&ENTED 6T DEFECTlvE SAMPLES. 23 SOIL CONDITIONS • SEE SECTIONS ON GRADING, DRAINAGE AND SOIL PREPARATION STANDARD&. FART 3 • EXECUT la-I 3.1 PLANTING -GENERAL A RELATIYE POSITION OF ALL TREE& AND Fl.ANTS 15 5U6JECT TO APPROVAL BT LANDSCAPE ARCHITECT AND SHALL, IF NECESSARY, ElE RELOCATED AS DIRECTED A5 PART OF Ca-lTRACT. 6. PLPNT FITS SHALL 6E MINIMUM WIDTH ix LARuER THAN ROOT 6ALL. IF WATER WILL NOT DRAIN FROM HOLE OVER NIGHT, TAKE CAUTICl-1 NOT TO OVER WATER FLAN!&. C. SET 50 THAT, IIIHEN SETTLED, PLANT5 ARE I IN. HIG~ER THAN FINISH C.RAPE THAN THEY 60RE TO CONTAINER PLANT IN CENTER OF PIT, 6ACK FILL ll!TH MIX PER Fl.ANTING NOTE&. NO SOIL IN 111DDY CONDITICl-l 5HALL llE USED Cl-I BACKFILLING. NO FILLING WILL 6E PERMITTED AROUND TRUNKS OR STEMS. ALL BROKEN OR FRAYED ROOTS SHALL 6E PROPERL T CUT. D. DO NOT ALLOW PLANT& 10 DRY 6EFOR!c OR IIIHILE PLANTING. !(J:EF EXPOSED R15 MOl&T 6Y 11:PN5 OF II.ET 5AI.LDU51, PEAT M055, OR 6URLAP AT ALL TIMES DURING PLANTING. DO NOT EXFO&E TO AIR IJ!.IILE BEING PLACED IN GROLt-lD. WILTED PLANTS, IN PLACE OR NOT, ll!LL NOT 6E ACCEPTED AND SHALL llE REPLACED AT CONTRACTOR'S EXPENSE. E. LANDSCAPE ARCHITECT SHALL MAKE PE~ODIC INSPECTIONS DURING PLANTING. PLANTS NOT PROPERLY HANDLED, SPOTTED OR PLANTED SHALL 6E 5U6JECT TO REMOVAL AND REFLACEMENT. F. IN THE EVENT THAT UNDERGROUND CON5TRUCTION ll/Orl< OR 065,RUCTIONS ARE ENCOUNTERED AL TERNATlvE LOCATION& WILL 6E SELECTED 6Y LAND5CAPE ARCHITECT. LOCATION OPERATION WILL 6E DONE AT NO EXTRA COST TO OWNER 32 PLANTING OF TREES A SPECIMEN TREES SHALL 6E APPROvED 6T LANDSCAPE ARCHITECT WITHIN 3~ DAYS OF THE AWARD OF Ca-lTl<ACT OR 46 HOUR5 6EFORE DELlvERY, IIIHICHEvER COME& FIRST. SPECIMEN TREES DELlvERED THAT ARE DAMAGED OR CHAN'"..ED FROM 1..IE ii,RITTEN APPROVAL ARE SUBJECT TO REJECTION. 6. NO ,REE5 lo GAi.LONS AND OvER SHALL 6E PLANTED IN A HOLE THAT WILL NOT NATURALL T DRAIN IN 14 HOUR!, AFTER 6EING FILLED WITH WATER CONPJCT TEST TO MAKE THIS DETERMINATION, AND NOTIFY LANDSCAPE ARCHITECT OF RESULT PRIOR TO PLANTING. C. PLANT ALL SPECIMENS OCCURRa.:; IN SODDED OR GROUND COVER AREA& BEFORE FINAL FREFARATICl-1 OF THOSE AREAS. 33 PLANTING 5HRU65 AND GROUND COVER A REMOVE ALL VINES FROM 5T AKES, UNTIE, AND SECURELY FASTEN IN AN APPROvED MANNER TO •WALL, FENCE, OR OTHER SU!sfAr-E NEAR TO IIIHICH THEY ARE PLANTED. 6. SET IN CENTER OF PIT, IN VERTICAL P05r10N, 50 THAT AFTER ALLOWINC. FOR WATERING AND SEffilNG, CROUN OF ROOT 6ALL 15 I IN. A6DYE SURROUNDING FINISH GRADE TO PREvENT WATER ACCUMULATICN 32 SOILS TEST RESULTS PROVIDE TE&T RESULTS TO LANDSCAPE ARCHITECT AND CITY LANDSCAPE IN5PECTOR COl>flRM SOIL AMENDMENT& FRIOR TO APFI.ICATION AND 6ACKFILL. /&EE SOIL MAN.lr..EMENT NOTES) 33 PEJ;fORMANCE A SU6501L, I. 5CARIFY 5U650IL IN ALL AREAS CEXCEPT SLOPES 3,1 OR GREATER! TO 6E PLANTED TO DEPTH OF!> INCHES PRIOR TO FI.ACEMENT OF AMENDMENTS AND TOPSOIL. THE SOIL SUlsfACE SHALL 6E HADE LOOSE AND FRIA61.E. 1. REMOVE ROCKS AND OTHER 06JECT5 OvER 2 INCHES IN DIAMETER 6. TOP&olL, i~T AF'f'LICABLE! C. INCORPORATICl-1 OF SOIL AMENDMENTS. I. PLACE ADDITIVES UNIFORML T IN ACCORDANCE WITH 5PECFICATION AND SOIL TE&T RESULTS, INCORPORATE TO DEPTH OF PLACEMENT OF AMENDMENTS AND TOPSOIL. THE SOIL SU!sfACE SHALL 6E MACE LOOSE AND FRIABLE. 1. RAKE, DRAG, ROLL AND 5MOOTH THE SUFfACE UNTIL FREE OF HOLLOl!l5 AND RIDGES AND IT CONFORMS TO E51A6Ll5HED GRADE Fl.US OR MINIMUM I INCH IN lil FEET. 3. APFI. Y PRE-EMEi<i,ENT ..IERBICIDE IN ACCORDANCE WITH MANUFACTURE'& AND AGENCY RECIJIR!cMENT5. D. FINISH GRADE, I. UPON COMPLETION OF ROTOTILLING AND TOPSOIL PLACEMENT, ALL AREA& SHALL 6E WATERED TO SETTLE SOIL 1. IIIHEN THE 501L HAS DRIED ci.lli'ICIENTL T TO 6E READILY ll/OFl<ED, ALL LAUN AND PLANTING AREAS SHALL 6E GRADED TO PREVIOU&L T E5TABLl5HED GRADE&. 3. GRADES NOT OTHEl'J!IISE INDICATED SHALL ElE UNIFORML T LEVEL OR SLOPING 6ETllfEN GIYEN ELEVATICl-15. FINISH GRADE SHALL 6E SMOOTH, EVEN, UNIFOO'I PLANES WITHOUT ABRUPT CHAW.£ Cf ELEVATICN 4. SOIL AR!cAS ADJACENT TO lllJILDINGS SHALL SLOPE AWAY FROM illJILDING TO ALLOW FOR A NATURAL RUN OFF OF WATER, AND SURFACE WATER SHALL 6E DIRECTED AS INDICATED Cl-I THE DRAIIIINGS 6T REMODELING SU!sfACES TO FACILITATE NATURAL RUN Off OF WATER ,. LOW &POT& PND FOCKE!& &HALL BE GRADED TO DRAIN PROFERL Y, MAINTAIN 2% MINIMUM SLOPE. 6. FINl5H GRADE OF ALL Fl.ANTING AREAS SHALL 6E 6ROUGHT FLWSH WITH CURBS AND PAVING TO A55URE POSITlvE DRAINAGE OVER TJ.IE S(FfACE. 1. MAKE MINOR ADJU5TMENT5 TO FINISH GRADE A& DIRicDED EIT THE LAND5CAPE ARCHITECT. 3.4 CLEANUP A IMMEDIATEL T CLEAN UP &FILLS, SOIL, CONDITIONER$ Cl-I PAVED AND FINISHED SU,fACE AREAS. 6. REMOVE DEBRIS AND EXCESS MATERIALS FROM PROJECT SITE. END OF SECTION 3.4 IN&TALLATICl-1 OF GROI.ND COvER A PLANT GROIND COVER IN AREAS DESIGNATED ON FLANS. 6. KEEF GROUND COVER STORED ON THE 51TE MOIST AND FREE OF IN&EC15 AND ~EEDS. C. DO NOT PLANT GROUND COvER UNTIL INSPECTED 6T LAND5CAPE ARCHITECT. D. PLANT FLATTED GROUND COvER WITH FLAT SOIL INT ACT WIT~ ROOTS. 3~ FERTILIZER INSTALL CHIP TYPE FERTILIZER TABLETS PER THE PLANTING NOTES. 3b WATER 6A51N5 PREPARE RAISED WATER 6A51N A5 WIDE AS Fl.ANT BALL AT EACH Fl.ANT. WATER THOROUGHLY, 6ACK FILLING ANT VOIDS WITH ADDITIONAL PREPARED Fl.ANTING MIX DO NOT 6ASIN FLAT SIZED PLANT&. REMOVE ALL 6A51N5 PRIOR TO Fl.ANTING OF LAl:.N AND GROUNDCOVER 3.1 WATERING A APFL Y WATER IMMEDIATELY AFTER PLANTII\I:;, TO EACH TREE, 5HRU6, VINE AND GROI.ND COYER AREA BT HOSE. APPLY WATER IN A MODERATE STREAM IN Fl.ANTING HOLES UNTIL THE MATERIAL A60UT THE ROOTS 15 MOIST FROM 60110M OF HOLE TO TOP OF THE GROUND. 6. FOLLOUIING THE PLANTING OF GROUND COVER PLANT&, IMMEDIATEL r AND THORCIJGHL Y WATER EACH Fl.ANT. C, WATER PLANTS NOT EFFIC!ENTL T WATERED WITH EXISTING IRRIC.ATION SYSTEM WITJ.I HOSE. D. AFFI. T WATER IN SUFFICIENT CIJANTITIES, AS OFTEN AS SEASONAL CONDITIONS RECIJIRE TO KEEF THE GROUND MOIST AT ALL TIMES TO THE DEPTH OF THE ROOT 5r5TEM OF GRASS AND PLANTS. 38 PROTECTION CAREFULL r AND Ca-lTINUOUSL Y PROTECT AREAS INCLUDED IN Ca-I TRACT, INCL UP ING PLANT MATERIALS, FENCE SUPPORT$, ETC, UNTIL FINAL N"..,CEPTAll::E. ~~M9ljlON OF ll/Orl<, REMOYE RUBBISH, TRASH, AND DEBRIS Rlc5UL TING FROM OPERATION. REMOvE ECIJIPMENT AND IMPLEMENTS OF SERVICE AND LEAvE ENTIRE AREA INVOLvED IN A NEAT, ACCEPTA6LE CONDITION SUCH A510 MEET APPROVAi. OF LAND5CAPE ARCHITECT. 3.lil MAINTENANCE A. MAINTAIN ALL FI.PNTING AREAS IN VIOOROU5, THRIVING CONDITICl-1 6T WATERING, CLI.Tl'IATING, SPRAYING, WASHIIG Off WALKS, AND ANT OTHER NECESSARY OPERATION$ DURING THE ENTIRE PERIOD OF INSTALLATION AND EST 46LISHHENT MAINTENANCE UNTIL FINAL ACCEPTANCE. 6. CALE'-O)A~ MAINTENANCE PERIOD SH.ALL 6E CALC\ILA TED FROM INITIAi. ACCEPT ANGE 6Y LANDSCAPE ARCHITECT. C. IMPROPER MAINTENANCE WHICH HAT CAUSE THE POOR CONDITION OF Fl.ANTED MATERIAL AT TERMINATION OF SCHEDllED Ca-lTRACT PERIOD WILL CAUSE POSTPONEMENT OF FINAL ACCEPTANCE OF :Jl?Fl<. Ca-lTINUE MAINTENANCE OF SUCH AREAS AT NO ADDITIONAL COST TO OWNER UNTIL 11.1:)Fl( 15 ACCEPTED. D. KEEF ALL AREAS FREE OF DE6Rl5, llEEDED AND CULTIVATED AT INTERVALS OF NOT C.REATER THAN TEN /Ill! DAT5 AFTER INITIAi. ACCEPTANCE OF PNT AREA E. MAIN! AIN ADECIJA TE PROTECTION OF ALL AREAS. D.lt!AGED AREAS SHALL 6E RicPAIRED 1111EDIATELT. F. P051 FERTILIZE ALL AREAS PFTER THIRT'i (3il! DAYS AND EACH SIXTY (bil! DAT5 THEREPFTER OF MAINTENANCE G. REMOvE ALL 11!:EDS Ell HAND, AFTER WATERING, AT THIRTY 13€!! DAYS PFTER INITIAL ACCEPTANCE. APPLICATION OF OF D'iMID OR TREFLAN OR APPROVED PRE EME1<1,ENCE llEED Ca-lTROI. SHALL BE MADE IIIHEN, IN LAND5CAPE ARC~ITECT'S OPINION, PROJECT 15 l~STED WITH llEED SEED AND RJRTHER 11.EEDING WILL 6ECOME AN UNNECE55ART illJRDEN TO OWNER H. CALL FOR iNSFECTION PFTER EACH Ti-llRTY C3rll! DAYS OF MAINTENANCE. I. MAINTENANCE 5i-lAI.L Ca-lTINUE FOR PERIOD SPECIFIED IN PLPNilNG NOTES. END OF SECTION INSTALL ROOT BARRIER PER MANlfACTLIRER'S SPECIFICATIONS AND APPLICABLE MUNICIPAL CODES. -~_...o ___ INSTALL TREE PER FI.At!TING NOTES AND DETAIL5, NCLUDING GUYING OR 5TAKING, BACKFILL, MULCH, FERTILIZER, ETC. ,,,---LOCATE 6ARRIER AT PERD1ETER CURBS, WALKS, WALLS OR &iRUCTURES DO NOT WRAP INDIVIDUAL ROOT6ALL5 '-----HINIMuM PIT DEPTH EQU.\L TO BARRIER DEPTH FOR TREES RlcGIUIRING ROOT BARRIER, CO~PACT BACK FILL BELOW E TREE ROOT BARRIER NTS FROND TIE DETAIL NOTE· ALL BACK FILL TO BE WA1ER JEmD DURING PLANTING FOR MAXIMUM 51A61LIT'i TO 6E TIED PRIOR Til Fl.ANTING WITH ORGANIC TWINE 6ACK FILL 100% WASHED FLA5TER SAND FINISH GRADE ------------- PALM TRUNK TO BE PLUMB /VERTICAL/ l' LATER MULCH o,.J""i--,-ROOT 6ALL -!>' BACK FILL F PALM TREE PLANTING NTS -....__ __ Fl.ANT PIT-lx WIDTH, EQDEPTH ROOTBALL ORIGINAL ROOT BALL G SPECIMEN TREE GUYING NTS ~-MAXIMUM I, I SLOPE, COYE RED WITH REINFORCED STRAW ~AT NOTE-ALL I, GAL I 24' 60X TREE& $HALL DE ST ilJ<ED EXISTING GRADE NOTE, ---""--~~ BREATHER TU6E5 4 IN. FEFf. FIFE ~ WITH FILTER FABRIC I PER IS GAL TREE l PER 24' IN. 60X PROl1DE DRAIN GRATE CAF SET ROOT CROUN A60vE SURROUNDING 6ACKFILL , f---PREVAILING WIND 2' DIA PINE LODGE POLE STAKE CINCH TIE W/GAL V. NAIL i6T VIT! 24' FOR lo GAL> 32' FOR 14' 60X 4 PER TREE 6Arl< MULCH, 1-112 10 2' DEEP, MOISTEN AFTER FI.ACEMENT 3 IN. WATERING 6A&IN CONSTRUCTED FROM EXCAVATED SOIL MAXl~UM Id SLOFE, COvERED WITH REINFORCED STRAW MAT ·e-f-----c",:---FERflLIZER TA6LET FER NOTE5 l/3 DEPTH Cf HOLE -...... _ __:""--' AMENDED SOIL BACK FILL ~---ROOT 6ALL V'----f'_ANTING HOLE· 51ZE FER SPECIFICATICl-1 @ SLOPE TREE PLANTING NOTE, PROVIDE p,...-?,!cf""'1-,.,_ NOTE· ALL IS GAL 114' 60X TREES BREATHER TJl'lES t. t t , ', SHALL 6E 5TAKED SEPARATE FROM TREi;,I' 't..., ( PREVAILING WIND 6U66LERS TJ6E5 "i,_. 0 · TRIPLE STAKE WITH t__ -'---..,_,,, l' DIA 10 FT. LONG FINE LODGE POLE STAKE ElREA !HER TU6E5 4 --,,-tvt,;:;;.,.~,, 3 FT 61:LOW GRADE, 1 FT. A60VE IN. PERF. FIFE ~ I il,RAP WITH :. -~~ FILTER FA6RIC I PER I& GAi. TREE l PERl4' IN.60X PROVIDE DRAIN GRATE CAP SET ROOT 6ALL 2 INCHES A60VE FINISH GRADE WITH!i<UNKFLARE Vl516LE __ ../ CINCH TIE W/GAI. V. NAIL (6Y VIT! 24' FOR lo GAL· 31' FOR 24' 60X 2 PER &TAKE 2' NITROLIZED 6Arl< MULCH 4' WATERING SASIN FINISH GRADE 118---FERTILIZER TABLET FER NOTE5 I/; DEPTH OF ~OLE '----6ACK FILL MIX FER NOTE$ " ~--ORIGINAL ROOT 6ALL @DOUBLE-STAKED ;~T~l~xWIDTH,EQDEPTHROOTeALL NT& ~-SHREDDED NITROLIZED 6Arl< MULCH, 2' DEEP, MOISTEN PFTER FLACEMENT ~-3' WATERING BASIN FINISH GRADE AMENDED SOIL 6ACK FILL ~---ROOT6ALL ~----Fl.ANTING HOLE· SIZE FER 5PECIFICATION @) CONTAINER PLANTING 5 --1 --GROUND COvER TO 6E PLPNTED FROM FLA !5, CUTTINGS, LINER5 OR ONE GALLON CONTAINER$ FER PLAN 5Q FT. COvER PER NTS 5 ~ 0 b4 Fl.ANT& 100 Fl.ANT& 0 0 D ~ 0 Q 4' 1 00. FT II 5Q. FT 0 0 D 0 0 0 6' lb 2; Loo o 0 0 0 0 8' 28 44 1121' 4, ,~ "' 0 0 0 " 0 ~· u IW I j e t__0 0 5' lil0 1;6 18' 144 iis JsL 5G:UARE &PACING 24' 256 400 TRIANGULAR SPACING . C GROUND COVER PLANTING ,--'ENCE OR WALL 5PREAD VINE AND SEOJRE TO ADJACENT SU!sfACE SET ROOT6ALL TIGHT TO FCOTINt; SHREDDED NITROLIZED BAFl< MULCH, 1-1/l TO l' DEEP, MOISTEN PFTER PLACEMENT FINISH GRADE FERTILIZER TABLE! PER NOTE& V3 DEPTH OF HOLE CONCR!cTE IMPROVEMENT ,.:.~ .II--AMENDED SOIL 6ACKFILL f;:::.: '----=--~;:;.,;.:'.I.:,:''L -. -ROOT6ALL-SET I IN. A60vE FINl5H GRADE FLPNTING HOLE A& DEEP AND TWICE AS WIDE AS Ca-11 AINER @ VINE PLANTING ------FINl&H GRADE IN GROUND COVER AFfA 10 6E AT LEA&! I' 6ELOW MOW &TRIP FIN. GRADE ---6' X 6' CCWCRETE MOW STRIP ---3/4' CHAl"FER FINISH GRADE IN LAUN AREA TO 6E NEAF!L T FLUSH WITH MOW STRIP 0---t---'3 RE6AR Ca-lTINUOU5 /LAP 12' AT 5PLICE5) It-~% COMPACTED SUB-GRADE NOTES, FINISH SHALL 6E SMOOTH WOOD FLOAT PROVIDE EXPANSION JOINT AT 2~ O.C. MAX. COLOR PER PLAN CALL G1JT CD CONCRETE MOW STRIP NTS NT5 NTS AHLES LANDSCAPE ARCHITECTURE INC P.O. Box 1503 Rancho Santa Fe, CA 92007 858-756-8963 PROJECT NO.: 1218 w 0 <( _J (l_ a: <( -z (/) <( 0: z 0 <( LL _J ~ _J CL <( w 0 0 CL • 0 <( <( () _J a:i (/) (/') 0 <( _J z 0: <( <( _J (l_ I 0 SET ISSUE DATE INITIAL CD 31 JAN 13 FLAN CHECK 5 MAR 13 --- FLAN CHECK 14 MAR 13 F.IIJFLAN CHECK 21 MAR 13 - SHEET: L.4 APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. 'AS BUILT" DATE llTLE RruEWED BY: INSPECTOR DATE c--+--+-------e---+--+----+--~~Lc_1T_Y_O_F_CA_R_LS_BA_D_Jl~E,ml L..i...J . PLANNING DIVISION . ----------------------~---·- DA TE INlft,\L DATE Nlfl'IL DATE INlft,\L LAND. AFCI-I REVISION DESCRf'TION CITY APPRlVAL OTHER Afffi)VAI. PLANTING DETAIL& AND 5PECIFCATION5 PALOMAR PLACE PALOMAR AIRPORT ROAD CARLSBAD, CALIFORNIA I APPROVED, /1.:-l ~ fx. ~L.,.-H-- MNNll,G <-\,L~-1'? DATE DWN BY: PROJECT NO.• DRAWING NO.• CHKD BY: FlB.D B~ &DP 90-0~/ G! 471-~L • i • _. -A I ITRA5~ I rl I I I I I I " C r', . STEM WALL & WA -ER PROOFING DEEP FOOTING , '4 _, 2!_: __ ~-~ WATER FLOUIS FRCM .Jt---<. IHPElst'IEABLE 5U!<fA INTO LANDSCAPE IRRIGATION PLAN NORT~ 20 40 FT. I 1 111111111111111111111111t -J 1111111111111111111111111111111~11~l1~ 5CALE • I" 314 : / lf=/8 :,o OAD-77.75 PALOMAR AIRPORT ROAD PROPOSED FIRE? SERVICE 1. POINT OF CONNECTION DO~STl'fAM OF I Di RECYCI.ED METER ~5 F51 DE&IGN f'RE&SU,£ ms l,i;I.~ vE~Fl' PRIOR 10 STA1'11:NG WRK MAINTAlN EXl&T~ BACKFLOW f'REYENTER AND PRES5Usf sftlll1.ATIC!4- FIEI.D TEST AND CERilFl DEVICES LOCATE BACKFLOW IN SH!l<6 AsfA PER LOCAi. CODE --- cX!ST. WATER MAIN ----IIN, sfCYCI.ED METER ----=:_~=--=--=-:__-==\- STATICl4 34'46.10, 1 IN, SERVICE FEAK DE!t'ND-11.1 GA1 -------------------------i . I r RECYCLED WATEi< EASEMENT$ r-r-t --1 - . '< I l I ' I " ~5 I ~ , ... I -. .. 11--'-o-,++-f+--•-a~" . -· ·314 ' C C PROP. FIi'!" 5ERVIC llJ/ EDC AND F IV / C P~OP0 "IR, SERVICF.W---c""-FDC i'1 °1V C 'C ------ • o·3/4 I. EXl&TINCi CJRE! l S89"33'25"E HYDROZONE <PER UJA TER EFFICIENT LANDSCAPE ILORK5HEET! HYDROZONE KEY MAP rn 0w-W~ NORTH SCAI.E 333. 91' I I , .,....-UUJ-fOOlll'!G ' I : • II ~b I I I I II ii , II., I FF 80.08 PAD= 79.25 ~EXISTING MEDIAN TO I / isEHAIN , ':!; 0::: 0 -st'. 0 <,: ::,; 0::: <,: I ' I I I ----- ---'-5ET 5PRA Y HEAj 13ACK 2/ INCI-IE5 FRCl1 EDl:.E Of PAVI~, EXTE.NDIDRIP L~E,& TYPICAL WriERE 'LAND& APE , I 314 I D INS TOUJA,5 5TR!J T5 --;:J 3: I -, -1 --llic ----- ---I----- CAAi..!l!.iJl PEl11'1.1166BO I ____ j U• I :> "' 1- I """"'~ ~ ;;£TA!R. UWJ. I ~-◄3'I ·--1, 11·, EJcm.;!El'atlllA"U---. j PCtl"~CCltW.O,. D'..1@:!0.,,~''-i!. ~l__ . i . -jl ~-- •I I -. ·~I I """"=4c ff~:,' ·:~-• i<-. ~t¼-h , I ~ ;I e::! ~ " ~µ.,,< ca/,,,d I ii! !1., .. o'r+t+++ttti: l -• i /'1 I I i tW,,-,· :U:-1 -~ · 1::~--l I/ ::,, ...•.•.••... ,,1 ·. I ,· -I 'LL,U.L.liL/J-'-~ I L..,-~,;:,1--_-·-_·-~~,_• 1 ,,-_-__,' . -. _ 1 , ~ PRDf'. WATER II.II~ "W"t Sl).;]'~'t --~-- -, .... 111·~ --···- I I -1J I I I t i DATE NmAL IRRIGATION LEGEND IRRIGATION HEADS SrMXJi. M4KE /'/OPEi NOlllF PSI ,FM R /,RC {)fT.4/1 MP ROTATORS PR05-U-m.w-CY-R ,t. i-lJN1ER 40 8 ADJ. F,\.-6 tfl,W-!oill A(tW! l W-2121 l .14 (I 18'11) 0 tf~511<1P 22 5x30 e: If SIDE 511<1P M 5xl5 3bel PR05-t-m.w-CY-R f,\A, ~ ~ If 200ill 4" 13-21 AP~ If 200ill·W A (I W) J. W-2121 .14 (• 18'11) If 200ill-3htl IS 3h/D tf3/Z)tltl 22-,tl />DJ. tf 31nt1-W /J6 (I W) J. in (t 18'11/ BUBB.ER V RAn-161RD ~-BC-14m ,ti 1'5 FWv!Pf .'W PER ll'EF /OPPOSITE WES CF ll'EE) SOAKER LINE ---NETAFIM TLR~b-ll 2!i 0.1, GP.JI LF .0102 C.FMILF IA! 1£tilflM TLA'IRI' [El 1£T,,lflM TLYF-1 i X4 TE 6/lf3S/Jfc'.4CE &04K£R IRR//J4 Tia/ T/JBM r ,/RCl/JI/C//T S/-IRI/B P/A'IT/NJ A.REA· fleC:/RF 7/JBM /JI/TH l"',AM/,4&ACTJRER'S .STAPLE~ COl£R/jJJT/-I MilLCI-I. m1VIOE A~ ,REUS: VAL J.,fS AND f!. ~, VAL v.:$ AS W/C:,t, tEO Iii/Tl-/ AJ)f)/TICNA/. AS NECESSAR'r FOR PROffR Offl'!ATW f,aJV/{)f Ali Pl!RMA¥JACI'JR£R~ SffaFICATW OTHER EQUIPMENT Srl'IXJ/. MA<E /'/OPEL 5/IF PEacl?IPTlCN W-2121 WL-6 J/ L • 1 Ki L-1 I.I L-1 Pf SCRIPT/CW FOP UP &'MAM ROTOR FOP LIP STRE,ltl ROTOR neeueet.ER TECHLINE LASE~ TUB!N~ FOR RECYCLED WATER AIR F£LIB' VAl.11: Fl.USM VAl.11: PFTAIL/Sl/ffT B HJ,111:R IC -600-1!6 U 5TATlctl 111AU. l"OLNT CCWROLLER w!&TAl'US& CA61NET M-6 ~ 111' EXP,IN51ctl HODULI:& TO ACOaiOPAlc ALL STATW UV IOITER SOLARS'l'NC AIJTctlATIC R.4"1 5l-4JT c:!'I' a 19:BCO &251"A I IN. 6ACl<Ft01ll f'l;£Vl:N!ER a,\.-6 IIIILKENS 5001' 1-1/2 IN. ~SIR "1:GIJLATER Wol.11'5 m 1-1/2 IN. r 51RA"11:R 0 RAIN61RD FE55R FER KEY CONTROL VAL'lc-RECYCLED CA.-6 ~ RAIN61RD XC:Z-IW-~ I IN. DRIP YAL'IE, f!L'IER, Rl:OOLATOis, 6ALL VAl.11: [ ~5TATICNt-lJ1flER VAi.YE KEY X VAl.11: SIZE VAL vE r.Fl1 @ NcLSON '164!i I' QUICK COilFLER VAL VE D,1..-6 M 1<51 6TU~E5 LNE SIZE '1'l<IE IJ.11ctl' 6ALL VAL \II: EIL-6 5CH 40 l•l/2' P\IC Ff,£iiSUF£ MANI.IIE -PcRP .E COLOR --Ii- [Cl. 200 FER PLM -----+ 5CH 4" lll'OIIL Y P\IC LA'l!RAL -P,RP .E COLOR P\IC LA'l!RAL ·Fe RF .E COLOR 5CH W 2X LINE P\IC 51.EE\11: 5CH 4" 2' P\IC EJ..l:CTRICAL 51.EEVf NOTE SLff>f' T(ff Al/!) {)fPT/1 AS FOL/Cl/Ji .411 Siff ,£S /)/0/'R 1$1/!CIF P.4 v!}/J-aCil a,, /IP J6 iii CO;fR MAINLINE AN{) 11/;'fiE iJN!)ER f'EOE&JR.4111 PAVIJ.t:-SCI-I 4£' UJI ~IN.COYER L..4T£RAJ.S /)/OfR ffPESTRA//1 PAVM· X/14e W Ii IN. CO>f'R NOTE, EX/EN{) AU 5!.ff>f'S Ii' /3frC/I/) f{Y,E CF PAVM * RECTCL:D WATER SIGN THIS SYSTEM UTILIZES RECYCLED WATER ALL l~FROVEME~TS PROVIDED UILL BE CONSTRUCTED FOR RECTCLED WATER USE, AND S~All COMP_ TWIT~ ALL LOCAL .AND HEAL!~ DEPARTMENT lsEG'JLAT!ONS. RECYCLED WATER NOTES ON 5~EET I AND DETA'L& BE'.OW SUFFLIHENT T.JESE PLAN5A ND SFECIFICATIONS. SEE IRRIGATION NOTES AND DETAILS TEMPORARY CONSTRUCTION NOTE 1,1..-1 -POTA13LE WATER IS TO 13E USED FRCl1 A TEMPORARY SOURCE UNTIL ilJ=TER A CR055 CONNECTION SHUT DOllN TEST IS COMPLETE, -TEMPORARY SOURCE &HALL i3E A CONSTRUCTION HETER ON A FIRE HYDRANT. -A 13ACKFLOUJ PREVENTER WILL 13E REQUIRED DOI.IN&TREAH Of THE CONSTRUCTION HETER • ALL IRRIGATION &'!'STEMS HIGH LINED (Ai30VE GROUND FRCM TEMPORARY WATER SOURCE TO HAIN CONNECTION FOR IRRIGATION) UNTIL CROSS CONNECTION TEST 15 PA55ED AND APPROVED er CHWD AND DEH. • EXISTING RECYCLED WATER HAIN NEEDS TO flE CUT AND CAPPED. AHLES LANDSCAPE ARCHITECTURE INC P.O. Box 1503 Rancho Santa Fe, CA 92007 858-756-8963 PFOJECT NO.: 1218 w 0 <( _J Q_ 0:: <( z U) <( a: z 0 <( LL ...J ~ ...J 11. <( w 0 0 11. 0 <( <( 0 _J O'.l U) (J) 0 <( ...J z a: <( <( ...J Q_ I 0 SFT ISSUE -DATE INITIAL CD 31 JAN 13 PLAN Cf.lECK SMAR13 PLANCf.lECK 14 MAR 13 RU! PL~ CHECK 21 MAR 13 SHEET: L.5 APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE UJCA TION OF PLANTING AREAS. 'AS BUILT' DATE TTLE REVIEWED BY: INSPECTCTI DATE _________ -_-~_-_-:==:======~~=-= I ~;Er, I. _c_iT_Y_o_F_c_A_R_L_s_s_A_o__, I ~E,ETS I _ PLANNING DIVISION REVISION DESCRIPTION IRRIGATION FLAN DA TE INTIAL DATE INTIAL I OWN BY: >---~--+--~----< CHKD BY: CITY AlfflJVAL OTHER APPFOl'Al. FIELD BK PALOMAR PLACE PALOMAR AIRPORT ROAD CARLSBAD, CALIFORNIA PROJECT NO,, 5DP 90-IZIS(G! DRAWI-IGNO; 411-SL IRRIGATION &Y5TEM PART I • GENERAL IJ DE&cRIPTION A. roRK INCLUDED, IRRIC.ATION SYSTEM Sl40UN ON DRAWINc.5 AND SPECIFIED HEREIN COMPLETE IN PLACE, TESTED, APPROYED, INCLUDINc. 13UT NOT NECESSARILY LIMITED TO, l CONNECTION OF &Y&TEM TO EXl&TI~ WATER &LIPPI. Y 2. REVIEW OF UTILITY PLANS &HCUIINc. OTHER UNDE~ND UTILITIES 3. TRENCHING A"iD 13ACK FILL 4. DRIP AND &PRAY IRRlc.ATION 5Y5TEM 5. AUTOMATIC CONTROLLER AND REMOTE CONTROL VALVES 6. RECORD DRAWINc. AND &cHEDULE ~JBMITT ALS 1. INCIDENTAL WDl<l< NOT SHOUN OR &PECIFIED IJI.IICH CAN REASONA13LY 13E INFERRED AS PART OR AND NECESSARY TO PROVIDE A COMPLETE AND OPERA6LE &Y&TEM. 6. RELATED WORK, DOCUMENTS AFFECTINc. WOi;K OF THIS SECTION INCLUDE, 13UT Al<E NOT NECESSARILY LIMITED TO GENERAL CCNDITIONS AND OTHER SECTION& Cf THESE 5F£CFICATION5. 1.2 F£RMIT5, FEES AND CODES A. 06TAIN ALL F£RMIT5 AND FAY REOOIRED FEES TO ANY GO\/El<NMENTAL AGENCY HAVING .!JRloDICTION ON COMPLETION OF WOsl<, Pl<ESENT SATISFACTORY EVIDENCE TO LAND&cAPE ARCHITECT THAT WDl<l< 15 IN ACCORDA'ICE WITH ORDINANCE AND CODE REQUll<El1ENTS. ARRANc.E FOR IN&F£CTION5 REQUIRED 6Y LOCAL ORDINA'lCE DURINC, CON&Tl'lJCTION 6. CONFORM WITH APPLICA13LE CODES, STANDARDS, LAWS AND REc.uLATIONS. NOTHING IN DRAWINGS OR SF£CIFICATION5 SHALL ElE CON&Tl'lJED TO F£RMIT NON CONrORMINc. WDl<K SHOULD CON5Tl'lJCTION DOCUMENTS OR INSTl'lJCTIONS VARY FROM AFOREMENTIONED FlJLES AND REC.ULATIONS, NOTIFY LAND. ARCHITECT, AWAIT INSmJCTION513EFORE PROCEEDINc. WITH AFFECTED WDl<K 1.3 S/411:TY ORDERS MAINTAIN WAl<NINc. SIC.NS, 6ARRIERS, SHORINc. REQUIRED llY LOCAL ORDINANCE OR OTHER Ac;ENCY. '.4 QUALITY A&&URANCE A. A SUPERVISOR CAPA6LE OF INTERPl<ETINC, THE DRAWINc.5 SHALL ElE ON SITE ALL TIMES DJRINc. CON5Tl'lJCTION 6. U5E ADEQUATE NUM6ER OF &KILLED WOi;KMEN, THOROJGHL Y 'TRAINED, EXPERIENCED IN NECESSARY CRAFTS AND COMPLETELY FAMIL!AR WITH &PECIFIC REQUIREMENT& A'lD METl40D5 NEEDED FOR PROPER PERFORMA.'ICE Cf WDil<. C. ALL MATERIALS &HALL l3E NEW AND IN NEAR PE~ECT CONDITIONS. DECISION OF LAND&cAPE ARCHITECT I& FINAL IN DETERMINATION OF QUALITY OF MATERIALS, EQUIPMENT, WDi;KMANSHIP. :,1; EX15TINc. SITE CCNDITION& A. ACQUAINT SEU' WITH ALL &ITE CONDITION&. SHOULD UTILITIES NOT SHO!N ON PLANS l3E FOUIND DURINc. EXCAVATIONS, PROMPTLY NOTIFY LANDSCAPE ARCHITECT FOR IN51"1JCTION5 FOR FURTHER ACTION FAILURE TO DO SO IIJILL HAKE CONTRACTOR LIA13LE FOR ANY AND ALL DAMAGE THERETO ARl&INc. FROM OPERATIONS, SU6SEQJENT TO DISCOVERY OF SUCH UTILITIES NOT &HOUN ON DRAWINC,S. B. MAKE MINOR AD.!J&111ENT5 TO &PRINKLER &Y&TEM LAYOUT A& MAY l3E REQUIRED, A"iD WDF<K AROUND EXl&TINc. CONSTl'lJCTION AT NO INCREASE IN COST TO OIINER !t, DELIYERY, &TOR.Ir£ AND HA"iDLINc. PROTECT WOl<l< AND MATERIAL& UNDER THI& SECTION FROM DAMAGE DURINC, CON&TRUCTION AND &TORAGE. POLY VINYL CHLORIDE (PVC/ PIPE AND FITTINc.S SHALL 6E E&PECIALL T PROTECTED FROM DIRECT 5UNLIGHT. 1.1 &U!lSTITUTIONS NO DEVIATIONS FROM SPECIFIED EQUIA1ENT OR IN&TALLATION PROCEDURES SHALL 6E ALLOll!:D WITHOUT WRITTEN APPROVAL OF LAND&cAPE ARCHITECT AND CITY INSPECTOR I.fl SUBMITTAL& A. EQUIPMENT &UBMITTAL, PRIOR TO COMMENCEMENT OF CONSTl'lJCTION, &U!lMIT FOR REVIEW A LIST OF ALL IRRIC.ATION EQUIPMENT TO 6E U&ED, MANUFACTUl<ER'S 6ROCHURES, MAINTENANCE MANUALS, WARRANTEES, AND OPERATION INS7l<lJGTION5 13. Pl<E55URE DOCUMENTATION, PRIOR TO INSTALLATION OF ANY IRRIGATION MAIN OR LATERAL Llt-0;5, SUBMIT DOCUMENTATION OF FIELD TESTING OF &TATIC WATER PRE&&URE AT THE POINT OF CONNECTION C, RECORD DRAllll!-1:;&. PRIOR TO CONDITIONAL ACCEPTANCE, SUBMIT REDLINE DRA1111% OVi:R A CLEAN &ET OF PLANS 51-iOWING DEVIATIONS FROM BID DOCUMENT& MADE DURINc. CON&TR!JCTION AND LOCATINC. CONTROLLER, POC, MAl~LINE PIPE, CONTROL QUICK COUPLER AND 6ALL VALVE& AND ALL &LEEVINC,. ITEMS SHALL 6E LOCATED 6Y WRITTEN DIMENSION FROM TWD FIXED CONSTl'lJCTION POINT (IE. CU1<6, LIC.HT 5T ANDARDJ. DEVIATION& IN &PRIHKLER HEAD TYPE& OR AREA OF COYEl<Ac.E SHALL BE FURTHER NOTED. l<ECORD DRAIIIINc.5 &HALL l3E DELIVERED TO LAND&cAPE ARCHITECT AND LOCAL JURISDICTION (AS APPLICA61.E/ 6EFORE PRIOR TO ACCEPTANCE. D, CONTROLLER CHART. SCHEDULE AND INSTl'lJCTIONS, PRIOR TO F111AL ACCEPTANCE, PER PART 3.S 1.9 GUARANTEE A. C.UARANTEE ALL WD!<l< FOR ONE YEAR FROM ACCEPTANCE DATE AGAINST DEFECT& IN MATERIAL EQUIPMENT AND WOi;KMANSHIP. C.UARANTEE SHALL COYER DAMAGE REPAIR TO ANT PART OF Pl<EMl&E& RE&UL 11!-I:; FROM LEAi<& OR DEFECTS IN MATERIAL, EQUIPMENT, ~IP TO SATISFACTION OF LANDSCAPE ARCHITECT. 6. PROMPTLY MAKE REPAIRS UPON NOTIFICATION 6T LANDSCAPE ARCHITECT AND AT NO CO&T TO DIIN:R PART 2· PRODUCT& 2.1 PIPE A. PLASTIC PIPE I. USE POLY VINYL CHLORIDE (PVC/ TYPE 1121!'· 1221!> PIPE UNLESS OTHERWISE INDICATED ON PLANS. HAINLINE SHALL 6E SCHEDULE 40 PVC FOR SIZES 1-1/2' AND SMALLER, CLASS 315 FOR SIZES. 2' AND LARGER, LATERAL LINES CLASS ;1; PVC FOR 1/2' SIZE&, CLA&S 200 FOR LARGER SIZE&, SLEEVINc. &cH. 40 6ENEATH PEDESTRIAN PAVINc., SCH. W BENEATH Vi:HICULAR PAVINc.. 2. FITTINGS, &cHEDIJLE 40 PVC FITTING& 3, e>OL \/ENT CEMENT, AS l<ECOMMENDED 6Y PIPE MANUFACTURER AND OF PROPER CONSISTENCY. HAINLINE CEMENT SHALL l3E A TWO STEP (PRIMER/ PROCESS. B RECYCLED WATE~ SYSTEMS, PIPE S~ALL BE F'JRPLE COLOR BY A.ER! LINE OR PACI' C CAL PPE 22 RISER A. POP UP HEADS, USE &cHEDULE W PVC NIPPLES WITH STREET ELL &WINc. JolNT& PER DETAILS 6. Rl&ER ;:£ADS• U5E C.RAT SCHEDULE 00 PVC NIPPLE& WITH &WINc. JOINT& BELOW C.RADE PER DETAILS. MEA&URE RISER HEIGHT FROM FINISH c.RADE TO TOP Cf RISER Rl&ER DIAMETER SHALL l3E 1/2', EXCEPT WHERE HEAD INLET IS LA,i;ER IN WHICH CASE RISER WILL MATCH INLET SIZE, UNLESS OTHERWISE NOTED ON DRAWl!-1:;5. C. &LOPE HEAD&, STAKE RISERS OF IMPACT AND GEAR DRIVEN HEAD& ON SLOPES WITH NO. 6 STEEL REINFORCING BAR, &ECURE WITH ADJU5TA6LE STAINLESS &TEEL C.EARED CLAMP. D. DRIP EMITTER RISERS, USEC.RAY SCHEDULE 00 PVC NIPPLES PER DETAILS, 2.3 &PRINKLER HEADS A. PROVIDE SPRINKLER "EADS SHOUN ON IRRl<:iATION LEC.END. 6. RECYCLED WATE~ SYSTEMS, HEAJ5 SHALL 6E 5PECIFICALL Y MADE FO~ RECYCLED WATER APP.ICATION tlTI-PURPLE COLOR CODING AI\D IN.EGRAL CHECK VALVE. 2.4 VALVi:S A. 6ALL VALVE&! PROVIDE 12; P.5J. RATED VAL YES CLINE SIZE/ l"ER LEC.END AND DETAIL& ON DRAWINc.S. 6. QUICK COUPLER vALVi:S, PROVIDE PER DRAWINc.S Al() DELIVER TO OUNER WI-EN APPLICA6LE, I. TWO KEYS FOR LOCKED CAP 2. TWO COUPLERS 3. TWD l40SE &mYEL& C. AUTOMATIC AND MANJAL CONTROL VALVi:S, PROVIDE PER LEGEND AND DETAILS ON DRAWINGS. D. RECYCLED WATER sn-EM5, VALVE SHALL EIE SPECIFICALLY MADE FOR RECYCLED I.ATER APPclCATION. WITrl REVER&EJ THREADING QUICK COUPLERS, PURFcE COLOR CODING AND D RTY WATER ' &C~UB6ER' CONTROL VA_ VE$. 2,I; DRIP IRRIC.AT!ON A. TUBINc.· 0.~;• ID. POLYPROPYLENE 'SP,\c;HETTI' TU61Nc.. 6. EMlffiRS· PER IRRlc.ATION LEGEND ON DRAWINGS. C. &TAKE&· 4' POL TPROPYLENE EMITTER STAKES. D. RECYCLED WATER S'51EMS-P,RPLE COLOR WITH INTEGRAL CHECK VALVES Zh EIACK FLOIII Pl<EVi:NTER/PRES5URE REC.ULATOR A. PROVIDE 6ACK FLCUI PREVi:NTER SHOUN ON LEc.END AND INSTALL PER DETAIL ON DRAWl!-1:;S. 6. INCORPORATE Pl<ESSURE REc.uLA TOR AND FILTER DEVICE IN A5&EM61. Y PER DETAILS AND DRAU!Nc.5. 2.1 AUTOMATIC CONTROLLER A. PROVIDE CON:ROLLER Sl40!N ON LEc.END ON DRAWINGS. PROVIDE ALL MOUNTINc. EQUIPMENT AND HARDWARE REQ1;IRED FOR PEDESTAL OR WALL MOUNTING AS INDICATED. 13. CONTROL WIRE&. 24 VOLT SOLID UL. APPROVi:D FOR DIRECT BURIAL IN C.RtmD. BLACK ~4 DIRECT LEAD AND UJ.IITE ~2 UF COMMON GROUND, UNLESS OTHERWISE NOTED ON DRAWIW.,S. 2.fl OTHER MA TE RIALS A. BACK FILL, LOCAL SOIL, CLEAN, FREE OF RUBBISH AND ROCKS OVi:R 2 INCHES DIAMffiR 13. PLASTIC VALVE 60XES, PLASTIC VALVE 60XES WITH LIDS "OR BALL VALVES CRC\11D! AND AUTOMATIC CONTROL VAL YE5 (2 PER 60X MAXIMUM/. PLACE 6' DEPTH PEA PEA C.RAYEL AT 6A5E OF 60XE&. FOR RECYCLED WATER APPLICATION, LID& SHALL BE FURPLE COLOR C. CHECK VALVE&, PRCVIDE &PRINc. IN-LINE CHECK VALVi:S (LINE SIZE!PER PLAN AND A& l<EQ\JIRED TO Pl<EVi:NT LOU: HEAD DRAINAGE. D. RECYCLED WATER &Y51=M5, P~OVDE &IE AND CONTROLL=R &IC.NAG: A5 l~DICATED ON DRAnlNGS. E. PROVIDE OTHER MATERIALS NOT 5PECIFICALL Y DESCRIBED l3UT REQUIRED FOR A COMPLETE IN&TALLATION AS &ELECTED BY CONTRACTOR 5U6JECT 10 APPROVAL OF LANDSCAPE ARCHITECT. PART 3 • EXECUTION 3J 5U~ACE CONDITION& A. Vi:RIFY FINISH c.RADES AND mACE DRAINAr,E WITH LANDSCAPE ARCHITECT PRIOR TO COMMENCEMENT OF WO;:K 6. EY.AMINE AREAS AND CONDITION& UNDER WHICH WOi;K WILL l3E PE~ED. CORl<ECT CCNDITIONS DE'TRIMENTAL TO TIMELY, PROPER COMPLETION OF lLORI( DO NOT PROCEED UNTIL UNSATISFACTORY C®ITIONS ARE CORRECTED. ,2 FIELD MEASUREMENTS MAKE NECE55ARY MEA&UREMENT& IN FIELD. EN~Jl<E Pl<ECl&E FIT OF ITEM& IN ACCORDANCE WITH DESI&< 3.3 LAYOUT A. LAYOUT WOi;K AS ACCURATELT AS P05516LE TO DRAWING&. DRAWJNC,S, THOUGH CAREFULLY DRAIN, ARE C.ENERALL Y Dl,\c;RA'1MATIC TO EXTENT THAT &WINC. JOINT&, OFFSET& A"ID ALL FITTINc.S ARE NOT SHO!N. SITE CONDITION& WILL NOT ALWAYS PERMIT LOCAT'NG PIPINc., VALVi:5 AND HEADS '.ilHERE 5140UN. THIS SITUATION SHALL 13E 6ROUGHT TO IM'IEDIATE ATTENTION OF LANDSCAPE ARCHITECT AND RELOCATION DETERMINED IN JOINT COffERENCE. CONTRACTOR 15 RE5PONSl6LE FOR RELOCATINc; ANY ITEMS INSTALLED WITl40UT FIRST OEITAINING LANDSCAPE ARCHITECT'& APPROVAL AND SHALL l<EMOYE AND RELOCATE SUCH ITEMS AT OUN EXPENSE IF SO DIRECTED 13Y LANDSCAPE ARCHITECT. 6. WHERE PIPING 15 SHOUN ON DR,\WINc;S TO l3E UNDER PAYED AREA& EIUT FlJNNI~ PARAU.EL AND ADJACENT TO PLANTINc. Al<EAS, THE INTENTION 15 TO INSTALL PIFINc. IN PLANTED AREA. C. MINOR CHANc.E& IN EQUIPMENT LOCATION FROM THAT SHOUN ON DRAWl)IGS &HALL BE MADE A5 DIRECTED BY LANDSCAPE ARCHITECT AT NO ADDITIONAL COST TO OUNER, PROVIDINc. SUCH CHANGE 15 ORDEl<ED 6EFORE COMMENCEMENT OF WO~ OR roRK D!RECTL T CONNECTED. AND NO ADDITIONAL MATERIAL& ARE REQUIRED. D. OFFSET ALL SPRAY HEADS A MINIMUM OF l4 IN. UJ.IERE ADJACENT TO STREET OR OT~ER IMPERMEABLE &U~ACE IJI.IICH DOES NOT RUNOFF INTO PEFY-EA6LE LAND&cAPE AREA. 3.4 TRENCHINc. A"ID BACK FILL A. PE~RM ALL EXCAVATIONS AS REQUIRED FOR INSTALLATION OR OOR< INCLJDED UNDER THIS SECTION, INCLUDING 5HORINC, OF EARTH 6A.'JKS TO Pl<E\/ENT CAYE INS. RE&TOl<E ALL &Ul<FACE&, EXl&TINC. UNDEli!iROUND INSTALLATION&, ETC DAMAGED OR CUT AS A RE&ULT OF EXCAVATIONS TO ORIC.INAL CCNDITION& IN MANNER APPROVED BY LANDSCAPE ARCHITECT AT NO ADDITIONAL COST TO OUNER 6. TRENCHES SHALL 6E MADE WIDE ENOilCiH TO ALLOW A MINIMUM OF 4 IN.13ETU!:EN PARALLEL PIPE LINES AND &HALL BE SUFFICIENT DEPTHS TO PROVIDE THE MINIMUM COVi:R FROM FIN1$H C.RADE AS FOLL0\115, I. 18 IN. MINIMUM COYER OYER MAINLINES LESS THAN 3 IN. IN &IZE TO REMOTE CONTROL VALVE&, l. 24 IN. MINIMUM COVER OYER MAINLINES 3 IN. OR GREATER IN SIZE TO REMOTE CONTROL VALVE&, 3. 12 IN. MINIMUM COYER OYER LATERAL LINE& TO HEADS. 4. % IN. MINIMUM COVi:R UNDER VEHICULAR DRIVE&, PAJs!<'Nc; AREAS, OR ROAD&. C. EXCAVATE FOR IRRIC.ATION 5TSTEMS Ill TRENCHING, WITH SIDES NEAR!. Y VERTICAL A5 P05$16LE. ACCURATELY c.RADE THE 60TTOM TO PROV!DE UNIFORM ElEARING FOR LINE. D. SHORT SECTIONS OF TRENCH HAY l3E TUNNELED F, IN LAND&cAPE ARCHITECT'S OPINION LINES CAN ElE IN&TALLED &AFEL Y AND 13ACK FILL CAN BE COMPACTED PROPERLY. E. REMOVE BOULDERS AND OTHER INTEITTRINc. OBJECTS, BACK FILL VOIDS REMAINING AFTER REMOVAL OF OBJECTS. F. PROTECTION OF PERSONS AND PROPERTY, I. BARRIC.ADE AND OPERATE WA!<NINc. LIGHT5 FROM DUSK TO DAUN AT OPEN HOLE&, TRENCHE& AND DEPl<ESSION& OCCURRl!-1:; AS PART OF WDl<l< ON PROPERTY ADJACENT TO OR WITHIN PU6LIC ACCESS. 2. PROTECT STl'lJCTURE5, UTILIT1ES, SIDEWALK PAVi:MENT AND OTHER FACILITIES FROM DAMAGE CAUSED BT SETT"EMENT, LATERAL MOYEMENT, WASHOUT, OTHER HAZARD& CREATED BT WO;:K 3. DO NOT TRENCH INDER DRIP LINES OF EXISTINc. TREE&. G. DO NOT BACK FILL TRENCHES UNTIL REQUIRED Pl<E5SURE AND LEAKAGE TEST& HAYE BEEN PERFORMED, AND UNTIL 5Y5TEM5 AS INSTALLED CONFORM TO SPECIFICATION&. H. PROR TO 6ACK FILLINc., REMOVE ALL SHEETINC. OR SHORING. I. BACK FILI. FOR ALL TRENCHES AND EXCAVATIONS SHALL l3E COMPACTED TO ~0% DEN51TY. J. 6ACK FILI. TO LEVi:L OF ADJACENT ELEVATION&, ALLOWING FOR 5ETTLINc. A>JD COMPACTION. 3,1; INSTALLATION Cf PIPI~ A. PIPING DEPTH, INSTALL PIPINc. WITH AT LEAST THE FOLLo-lilNC, DEFTH OF COYER· PVC MAINLINI: LE&& THAN 3 IN DIA.-18 INCHE& PVC LATERAL· 12 INCHES POLYPROPYLENE MllNc.· 3 INCHE& 6. PIPING JNDER PAVi:HENT, SLEEVE PIPING UNDER PAYED AREAS AS INDICATED ON DRAWING&. EXTEND &LEl:VIN(; 12' 6EYOND EDGE Cf PAVINc., OJl<65, WALL& ETC C. IN5F1:CTION OF MATERIAL&. CAREFULLY INSPECT PIPE AND FITTINGS 6EFORE INSTALLATION, REMOVINc. ALL DIRT, SCA;.E AND 13URR5, REAMINc. AS REQUIRED. IN&TALL PIPE WITH MARKJNC,5 UP FOR Vl&UAL IN&PECTION D. PLASTIC (PVC/ PIPE I. l:XERCl&E CARE IN HA>IDLIN(;, LOADINc., UNLOADING AND STORING PLASTIC PIPE AND FITTINc.S. AJ &TORE UNDER COYER FROM Dll<ECT 5UNLIC.HT UNTIL READY TO IN5TALL. 6J TRANSPORT ONLY ON VEHICLE WITH 13ED LONc. ENOUGH TO ALLOIII PIPE TO LAY FLAT, TO AVOID UNDUE BENDINc. AND CONCENTRATED EXTEl<NAL LOAD. 2. REPAIR DENTED A>JD DAMAl:iED PIPE 6Y CUTT!Nc. 0NL Y AND Dl&cARDING DENTED OR DAMAc.ED 5ECTION5, l<EJOININc. WITH A COUPLING. 3. IN JolNINC., USE 0NL Y SPECIFIED SOLVENT. MAKE JOINT& IN ACCORDANCE WITH MANlfACTURER REC0'1MENDATION5. PIPE AND FITTINc.S SHALL 6E Tl40ROUC.HL Y CLEANED OF DIRT, DU&T, MOISTURE 6EFORE APPL YINc; SOL VENT. CLEAN OFF EXCESS SOL \/ENT. ALLOW SOLVENT WELDS AT LEAST 1; MINUTES SET UP TIME 6EFORE MOVING OR HANDLINC, AND 24 HOURS DING TIME 6EFORE FIU.INc. WITH WATER 4. &NA<:E LINES FROM SIDE TO SIDE IN TRENCH TO ALLOW FOR EXPANSION AND CONTRACTION. 5. FOR PLASTIC TO METAL COi'INECTION5- A./ WOl<l< METAL CONNECTION& FIRST. 6J USE NON HARDENINc. PIPE DOPE ON THREADED PLASTIC TO METAL CONNECTIONS. CJ USE 0NL Y A LIGHT II.RENCH PRESSURE. DJ USE JOINT COMPOUND ON C.ALVANIZED IRON FITTING&. E. FLUC. OR CAP ALL OPENINc.S UPON LINE INSTAU.ATION TO PREVENT ENTRANCE OF MATERIALS. F. THOROilCiHLY FLU&H ALL LINE&, PE~RM HYDRO&TATIC TE&TINc. PER PARAc;RAPH 6ELOIII. TESTING AND COMPACTION 3.6 INSTALLATION OF EQUIPMENT A. POF UP 5PRA Y HEADS I. INSTALL WHERE INDICATED ON DRAWING& IN ACCORDANCE WITH DETAIL& AND MANUFACTURER l<ECOMHENDATION A5 APPROVi:D 6T LANDSCAPE ARCHITECT. 2. LOCATE POP UP 3' FROM PEDESTRIAN PAVl!-1:;. Ii' FROM AUTOMQl31LE TRAFFIC WITl40UT OUR65, 6' FROM AUTO. TRAFFIC WITH CUR65 AND 6' FROM ALL 6UILDl!-I:; AND WALL FOOTl!-1:;& UNLES5 NOTED OTHERWISE. SET HEADS FLUSH TO ADJACENT PAVl:-IG OR C.RADE ELEVATION 3. UPON LINE TE&TINc. COMPLETION, COMPLETE AS5EMBL Y, ADJU&T &PRIHKLER HEADS FOR PROPER Dl5TRl6UTION. 6. RISER HEADS I. INSTALL IN PLANTINc. AREA& HRE INDICATED ON DRAWINC,S. !NONE ANTIC:fATED ON 'H!S PROJECT/ 2. POP UP5 SHALL 6E USED IN THE Rl<:iHT OF WAY AND IJI.IERE\/ER WITHIN 10 FEET OF ANY HARDSAPE, TUl<f OR OTHER AREA WHERE PEDE&~AN TRAFFIC MAY OCCUR, AND 12' FROM AIJTOM061LE TRAFFIC WITHOUT CUR6&, 6' FROM AUTO. TRAFFIC WITH CURBS AND&' FROM ALL 13UILDING AND WALL FOC,INc.5 UHLES& NOTED OTHERWISE. &ET &HM HEAD& EIC.HTEEN (18'/ INCHES A60\/E FINISH GRADE UNLE&S NOTED OTHERWISE (SEE DETAILS/ 3. lf'ON LINE TESTING COMPLETION, CO!fcETE ASSEM61. Y, ADJUST SPRINKLER HEAD& FOR PROPER Dl5TRl13UTION C. OFFSET ALL 5PRA T ,-!EADS A MINIMUM OF l4 IN. UJ.IERE ADJACENT 10 STREET OR OTHER IMPERMEA6LE &:ffACE WHICH DOES NOT RUNOFF INTO PERMEA6LE LAND&cAPE AREA. D. VALVES, INSTALL BALL VALVE& AND QUICK COuPLER vALVi:5 PER DRAWINGS. PROV!DE 6ALL v AL Vi:S TO SEPARATE QUICK COUPLERS AND CONTROL VAL YE CLUSTERS FROM MAINLINE. E. CONTROL VALVES, INSTALL U!-IERE SHOUN ON DRAWING&, LOCATJNC, IN CLU&TERS IN PLANT!Nc. AREAS WHERE PRACTICAL. PLACE NO CLOSER THAN 12' AND PARALLEL TO WALK EDGE&, 13UILDING5 AND WALLS. HOUSE IN VALVE 60XE& WITH TOPS &ET FLUSH TO GRADE. SEPARATE CLU&TER5 FROM MAINLINE WITH 13ALL VALVE. F. DRIP :RRIGATION, PROVIDE COl1"LETE &T&TEMS WITH IRRlc.ATION TO EACH INDIVIDUAL PLANT WITHIN THE ZONE OF DRIP IRRIGATION. I. ALL DRIP, !Ai PROVIDE &TATION SPECIFIC FILTER AND Pl<ES5Ul<E REG'JLATOR DOUNSTREAM OF EACH INDIVIDUAL DRIP VAL YE. (6! COVi:R DRIP TU61Nc. COMFLETEL Y mH MULCH. IJI.IERE NO MJLCH 15 5PECIFIED.13URY 2·3 INCHES IN SHOVi:L CUT TRENCH. 2. POINT EMITTER SYSTEMS, <Ai PROVIDE PVC PIFINc. FRO~ VALVE WITH R!5ERS TO EACH INDIVIDUAL OR l1ILTI PORT EMITTER LOCATION. (6! EMITTERS SHALL l3E FLUSH WITH FINISH GRADE, EXCEPT WHEl<E INDICATED ON PLAN TO 6E IN 6ELOIII C.RADE BOX (Ci ROUTE POLY Dl57Rl13UTION TUBl:-IG TO EACH INDIVIDUAL PLANT, QUANTITY PER IRRIGATION LEGEND AND ~TE&. II! FLINCH INTO LINE& WITH HA'-llfACTURER APPROVED PUNCH, IF APPLICA6LE. (l/ PLACE OUTLET AT Eoc;E OF WATER 6A&IN, A MINIMUM OF 6 INCHES~ PLANT STEM OR ml\K, (3! FOR &LOPE CONDITION&, LOCATE OUTLET& TO UPHILL 51DE OF PLANT &TEM OR TRUNK, ( 4! PLACE EMITTER 6ilCi CAP ON CIJTLET TUBINC, END, !5! STAKE OUTLET TU61Nc. NEAR END. 3. SOAKER TUB!Nc. SYSTEMS, !Ai PROVIDE PvC PIPING FROM VALVE TO MULTIPLE SOAl(J:R TuBE CONNECTIONS AS INDICATED ON l'HE PLAN MANIFOLD MULTIPLE CONNECTIONS TO FACILITATE UNIFORM FLOW INTO LINE. 16! LAYOUT SOAKER TU61Nc. TO UNIFORML T COVER AREA Cf IRRIC.AJ10N !Ci PROVIDE AIR RELIEF AND FLU&H VALVi:5 PER MANUFACTURERS SPECIFICATION&. c;, BACK FLOW PREVENTER, INSTALL WHERE INDICATED ON DRAWINc.S AND IN ACCORDANCE WITH ALL PERTINENT CODES, REGULATIONS, AND MANUFACTuRER'5 l<ECOMMENDATION5 AS APPROVED 6Y THE LANDSCAPE ARCHITECT AND LOCAL MUNICIPAL WATER DISTRICT. H. AUTOMATIC CONTROL SYSTEM I. CONTROLLER (A/ INSTALL AS SHO!N ON DRAWINGS, UNLESS OTHERWISE DIRECTED BY LAND&cAPE ARCHITECT, (6! CONNECT REMOTE CONTROL VALVES TO CONTROLLER IN SEQUENCE CORl<E5PONDINC, TO THAT INDICATED ON DRAWINGS. HRE TWO OR MORE VALVES HAYE SAME NUM6ER, WIRE TOGETHER AT CONTROLLER DO NOT C.ROUP DRIP AND SPRAT HEAD& ON SAME STATION (Ci ELECTRICAL &UPPL Y TO POINT OF CONNECTION SHALL 6E 6Y OTHERS. PRCVIDE 'HARD WIRE' &PLICE INTO EXl511Nc. JUNCTION 60X NEAR CONTROLLER LOCATION. 2. AUTOMATIC CONTROL WIRINC;, ! Ai INSTALL CONTROL WIRES, IRRIMTION MAIN& AND LATERAL& IN COMMON TRENCHES WHENEVER POS&IBLE. /6! INSTALL CONTROL WIRE& AT LEAST 18' 6ELOW FINISH C.RADE AND LAY 10 SIDE OF MAINLINE WHERE P05Sl6LE. WIRES &HALL 6E A MINIMUM I' FROM l>M' PIPE OR FITTINc. EXCEPT AT TERMINAL POINTS. PROVIDE LOOPED SLACK AT VALVi:5 AND SNAKE WIRES IN TRENCH TO Al.LOU: FOR CONTRACTION Cf WIRE. TIE WiRE 11 ~JNDLES AT le>' INTERVALS WITH PLASTIC ELECTRICAL TAPE. IC.I Wll<E SPLICES WILL 6E ALLOWED ONLY ON RUN& MORE THAN 500 FEET. CRiMP WIRE& TOGETl-l:R IIJITH APPROVED WIRE CONNECTOR AND 5EAL CONNECTION PLACE IN A130\/E C.RADE FULL 60X PER SAN DIEOO REC.IONAL &l<INDARD DRAIIIING ~-l!i. CD! PROVIDE SEPARATE SLEEVING FROM IRRIGATION LINE& FOR CONTROL WIRES 6ENEATH PAVINc.. WALLS. ETC. !E/ WIRES &HALL BE PLACE IN GRAY &cHEDULE 00 PVC ELECTRICAL SLEEVi: rROM 18' BELOW GRADE TO CONTROLLER AT CONTROLLER LOCATION. (F! PROVIDE EXTRA IIIRE& FROM CONTROLLER TO EACH VALVE CLUSTER PER IRRIGATION NOTES. 3. WEATHER CONTROLS, (A! PROVIDE PER PLAN AND LEGEND. CONNECT A"ID MAKE FUU. T OPERATIONAL PER MANUFACTURER'S &PECIFICATIONS 3.1 TE&Tl!-1:; AND INSPECTION A. DO NOT ALLCUI OR CAUSE ANY WDl<l< Cf THI& SECTION TO BE CO'IERED OR ENCLOSED UNTIL IT HA5 6EEN INSTALLED, TESTED, APPRO'IED BY LAND&cAF£ ARCHITECT AND CITY INSPECTOR REQUE&T INSPECTIONS AT LEAST FORTY-EIGHT (48! HOURS IN ADVANCE HOURS IN ADVANCE OF TE&TING. a FLUSH PIPE BEFORE 13ACK FILLING MAINLINE, 111TH CONTROL VAL Vi:S PLACED 13UT BEFORE LATERAL LINES Al<E CONNECTED, COMPLETELY FLU&H AND TEST MAINLINE. I. REPAIR LEAKS 2. FLUSH OUT EACH SECTION OF LATERAL PIPE BEFOl<E &PRINKLER HEAD& ARE ATTACHED. C. TESilNC;, l MAKE NECESSARY PROVl510N5 TO THOROJGHL Y 61.EED LINE OF AIR AND DE6Rl5. 2. tJ'TER VALVES HAYE 6EEN INSTALLED, HN WELDED PLASTIC JOINTS HAYE CURED FOR 24 HOURS, TEST MAIN W/TER LINES FOR LEAK& AT PRES&URE Cf 125 P.5.1. FOR PERIOD OF 24 HOURS WITH COUPLIW.,S EXP05ED AND PIPE SECTIONS CENTER LOADED IIJITH &UFFICIENT BACK FILL TO PREVENT ARCHING OR SLIPPING UNDER Pl<E&SURE. LATERAL LINES SHALL BE TESTED, WITH RISERS CAPPED, FOR TWO HOURS UNDER NORMAL STATIC Pl<ES5URE. 3. PROVIDE REQUIRED TE&TINc. EQUIPMENT AND PERSONIJEL. 4. REPAIR LEAi<&, RE TEST UNTIL ACCEPTANCE BY LANDSCAPE ARCHITECT AND CITY INSPECTOR D. FINAL IN&PECTION, CLEAN, ADJUST, 6Al.ANCE ALL SYSTEMS. VERIFY, I. HEAD& ARE PROPERLY ADJJ&TED FOR RADIUS AND ARC Cf COVERAGE. 2. INSTALLED SYSTEM 15 WDF<KABLE, CLEAN, EFFICIENT. E. RECYCLED WATER SYSTEMS, PROVIDE CROSS CONNECTION. C0',1:RAGE. OTHER TESTINC; REQUIRED SY HEAL Tl-DEPARTMENT OR •.ATER DISTRICT (SEE RECYCLED NOTES. Si-EET _-I!. ,.fl RECYCLED WATER &IGNACiE INSTALL A& SHO!N ON DRAWINGS OR REQl;ll<J:D 6Y HEALTH DEPARTMENT OR WATER DISTRICT. 3.9 INSTl'lJCTIONS A. ATTACH TYPEIIRITTEN LEC.END INSIDE EACH CONTROLLER DOOR, STATING AREAS COVERED 6Y EACH VALVE. PROvlDE REDLl'.;ED, LAMINATED. COLOR CODED MAP OF AREA IRRIGATED BY CONTROLLER 6. PROVIDE AN IRRl<:iATIIJN &cHEDULE INCLUDINc. THE FOLLCUIINc., • REFERENCE INFOl<tlATION-ETO DATA UTILIZED TO DEVELOP SCHEDULE, PROJECT SOIL CONDITIONS • APPLICATION WINDOW FOR OVERHEAD IRRIGATION-LIMITED 6ETUeEN le>,00 AM A"ID 6,00 PM • FOR EACH IRRIC.ATION STATION-RUN DAYS, RUN TIMES (UTILIZINc.11JLTIP1-E CYCLES TO AVOID FlJNOFF/ -FOR EACH STATION· PLANT TYPE, &LOPE AND SHADE FACTORS • SEPARATE &cHEDIJLES FOR PLANT E5TA13LISHMENT (INCLUDINc. TEMPORARY AREA&! AND EST A6Ll&HED, PERMANENT LANDSCAPE -SEASONAL OR MONTHLY ADJU5111ENT5 -ESTIMATED AMC\NT OF WATER TO l3E APPLIED ON A MONT~Y 13A51S. C. AFTER SYSTEM HAS 6EEN COMPLETED, TE&TED, INSPECTED AND APPRO-IED, INSTRUCT OIINER OR MAINTENANCE PERSONNEL IN OPERATION AND MAINTENANCE OF SY&TEM. 3.10 IRRIC.ATION SCHEDULE PROVIDE A WRITTEN SCHl:DULE OF LONc. TERM IRRIC.ATION PROORAMMING. C.ROUP STATIONS 6Y HYDROZONE AND SPECIFY FOR EACH ZONE- • MINUTES PER START TIMES, • START TIMES PER 11!:EK -TOTAL MINUTE& FER WEEK. PROVIDE A CHART OF MONT-IL Y FlJN TIMES FOR THE ABOVE. 6' ROUIND PLASTIC VALVE 60X 1~URFLE! ,.___ 13AU. VALVE WITH UNIONS (Sx&J j ~3/-'=-111 __ VALVi: 60X EXTENSIONS LENG TH AS REQUIRED 3/4' DIA. GRAVEL, HIN 12' DEEP ..: ,: " NOTE· ALL ~IRl!-1:; SHALL 6E PER LOCAL CODE AND Ufl.C. -CONNECT WIRINc. 111TH 'PEN TITE' WATERPROOF CONNECTORS ~ ':'_.'· ;: . :!" ~ .• . ~ "OH ... .. -11- 11 .,--CONTROLLER PER LEc.END. MOUNT TO WALL PER MANlfACTURER'& &PECIFICATION .,--JUNCTION 60XE5 _,--~0 V. POWER A'() GROUND _,--TO 121!> V. PO\LER SUPPLY 1.,. .... --PVC CCNDUIT ~-FLOOR LINE ~-FINISH GRADE F"''----1½' SLEEVE THROUGH WALL (INTERIOR APPLICATIONS/ ,-;;;;I>---DIRECT 13URIAL WIRE TO VALVE& --....__ 2' DIA. PVC 'lf!d &cH. 00 :>.IEEP ELL AHLES LANDSCAPE ARCHITECTURE INC: P.O. Box 1503 Rancho Santa Fe, CA 92007 858-756-8963 BALL VALVE NTs @ WALL MOUNT CONTROLLER NTS PROJECT NO.: 1218 FINl&H c.RADE '----PCf'•UP 5PRA Y HEAD FLJSH W/ GRADE (Wile PURPLE CAP/ --USE 60TTOM INLET FOR SAM HEADS rh~x-x::J~111---pvc LATERAL _.,___..J ~----&cH. 00 PVC NIPPLE '-------SCH. 40 PVC S,&,T TEE OR ELL NOTE, ALL &WINc. JOINT COMPOIJENT& &HALL EQUAL HEAD INLET SIZE 6RA55 UNIC!-1, TYPICAL PRESSURE REWTOR PER LEGEND UP&TRi:AM FOR CROSS CONNECTION TE&TING AJRP05E5 CONCRETE SI.All 4 IN. DEPTH X 16 IN. WIDrn Y-5TRAINER BRAS& NIPFLES, TTT'ICAL USE NO CLOSED NIPPLES FINISH C.RADE PVC MAINLINE 'lm-'L!.Lllljjr==:~-~ FLOW 1...-,_....r.:,.ff:ln.il,...., &cH. 00 (FIPTxS! p·vc ADAPTER COPPER 5UPPL Y LINE FROM l'ETER 12' X ll' X 12' CONCRETE w 0 <( _J ()_ a: <( z Cf) 0: CE) POP-UP SHRUB SPRAY NT& @ BACK FLOW PREVENTER W/P.R. NT& <( z 0 :5 u.. ~ _J POF UFS SHALL 6E USED IN THE Rl<:iHT Cf WAY AND r WHEREYER WITHIN 10 FEET OF ANT HARD&APE, TU~ OR QJµER AREA WHERE PEDESTRl<\N TRAFFIC MAY OCCUR 6' MIN. SEE SPEC&. FOR OTHER Cff&ET REGlJll<EMENT&• 14 IN. MINIMUM 111-iERE ADJACENT TO STREET OR ONER IMPE!i11"..A6LE SiJ~ACE ll!-IICH DOES NOT FlJNOFF INTO PEi<HEA6LE LANDSCAPE AREA. 5Hl'lJ6 HEAD OR 13UOOLER ~-PAVING, WALL, FENCE OR CURB ~-SCH. l¾l PVC RISER, &IZE PER ~EAD INLET FINISH c.RADE .__ W STl<EET ELL /M x F / Ir--'lf!d STREET ELL (M X FJ /~ SCH.40PVCTEEORELL/Sx5xF/ ~-PVC LATERAL LINE @SHRUB RISER ~-c.RATE =:::nj::::,,: r FINISH GRADE PVC LATERAL ~------&cH. 41!> PVC Sx5xT TEE OR ELL NT& ~-----FINl&H C.RADE ~--PVC LATERAL TO HEADS ---&cM. 40 PVC MALE ADAPTER ~-14'xlS' PLASTIC VALVi: 60X WITH COYER !PURPLE/ REMOTE CONTROL VALVE ~f-,l-"'--M='l!!i'i1:JF-~~ RECYCLED 1:.ATE~ WAR'llNr.i TAG ~-ii=--WATER PROOF Wll<E CONNECTIONS 1111 10 112' WIRE EXPANSION COIL& .,--II',:---&cH. W PVC UNION 4_;:~'i.ri~ ~~_,--\i+l, f---&cH. 00 PVC NIPPLE ~ 1111-&cH. 40 PVC W ELL (5xFIPTJ 314' GRAVEL, MIN. 12' DEPTH 0 -111 &cH. 40 PVC ' ' NT5 NO-J;, RECYCLED QUICK COUPLER SHALL BE DIFFERENT mo &HALL NOT BE INTERCHANGEABLE WITH ~o· A6LE WATE~ 'ITT Nc.S th: ~ IN. DIAMETER PLASTIC VALVi: 60X I COVi:R (PJRPLE/ ~--------lx2x24' RDW &TAKE ~-------QUICK COUPLER VALVE ~-'---FINISH C.RADE Q~-'-k-c=1~i;:::t:=t=-=t==:;rJJ-,,,.j--lrrr=-- :~ 11 1 I' DIAGRAYEL ~ ~ 'Rtr"i--F'"---5TAINLE55 STEEL HOSE CLAMP (2J ~ I ,,-f-Ftf-,1----I' &cM. w PVC RISER· ~· I :3 ! rlit;;JJ--+--I' &cH. 4il! PVC 'lfJd ELL (FIPTxFIPT/ ~ z_~ 111 kif--+---I' 'lf!d 5 TREET ELL (MIPT xFIPT! -I .w1~-+---I' &cH. W PVC NIPPLE ~; -"1---.=jj+JH.-1""-"-l" j.J,!J,--i=~-I' 'lf!d STREET ELL (MIPTxFIPT! ~ ~ Q~t--PVC HAll{.INE ,i: >= l!J,!L-C::.-SCH. 411) P'VC TEE rs,s, I' &) =-e_ __ I' &cH. 00 PVC NIPPLES 1111 '-+I --MALI, ADAPTER 0.. <( w 0 0 0.. 0 <( <( () _J en Cf) (f) 0 <( _J z 0: <( <( _J ()_ I 0 SET ISSUE DATE INITIAL CD 31 JAN 13 FLAN CHECK ~ MAR 13 FLAN CHECK 14 MAR 13 RUI FLAN CHECK 21 MAR 13 SHEET: L.6 (ID TREE BUBBLER NT& (Q) QUICK COUPLER VALVE NT6 APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. HYDROZONES SHALL l3E AS E&TA6Ll5HED PER THE WATER USE CALOJLATIONS, ADJUST TO REFLECT ACTUAL FIELD CONDITIONS AND CON& !RUCTION HYDRO ZONE& SHALL 6E 13A5ED ON PLANT TYPE, IRRIC.ATION TYFE, SOIL&, &LOPE ASPECT AND OTHER CONDITIONS. INCLUDE A SEPARATE SCHEDULE FOR PLANT E5TA6LISHMENT A"iD ANY AREAS OF TEMPORARY IRRIGAT!ON NOTE THAT THE &cHEDIJLE 15 PROVIDED 0NL YA& A C.UIDE, AND ACTUAL WATER USE WU VARY IIJITH WEATHER, PLANT MAINTENANCE A>JD OTHER FIELD CONDITIONS. 3.11 MAINTAIN SYSTEM FOR PERIOD INDICATED IN IRRl<:iATION NOTE&, OR LENc.TH OF PLANTINc; MAINTENANCE PERIOD, WHICHEVi:R 15 GREATER END OF SECTION --------------- 'AS BUILT' DATE TITLE REVEWED BY: INSPECTOR DATE 1--+--+-----------+--+--+--+-------11~~~1. _c_1T_Y_o_F_c_A_R=L~s_B_A_D__Jl~E1 8 sl I(;/ _ PLANNING DNISION DA TE INITIAL DATE IITTIAL DATE l~l!IAL LAfO. AFCH REVISION DESCRIPTION CITY Afl'FOV AL OlliER APPfDVAL IRRIGATION PETAIL5 AND 5PECIFICATION5 PALOMAR PLACE PALOMAR AIRPORT ROAD CARLSBAD, CALIFORNIA I APPROVED-11-JJfn Lt--~lL€>'\t-'-!-,~ -1"> DATE OWN BY: PROJECT NO.• DRAWINCl NO; CHKD BY: REI.D BK: SDP ':10-0,(G) 471-,L . -~==-=-•-·· ._,_ . __ ,_.._ STR!:ET 5UFfACE-~\ POTABLE SERVICE LINE \ !SEE IHPROVl31ENT DRAlllll-ti5J _ NOTES: , TH£ USTED PIPE A.ND nTTl~GS ,\J1£ INTENDED FOR A 2" WAITll s,RVICr ,\ND 1" COPPER PIPE AND FllllN,S MAY GE USE[) m~ WAT::k SERVICE, Z. IJ-lf(tADrn JO:NT flTT1NGS (NPl') MAY BE ,ISED IN Pl.ACE 0f SOJlEHLD .iOJN JS :;1 IOV\'N ON l!i1::i IJP.AWll-iG. 1 !2;, cQf,;-,c~ )( CO['Pl!?~l --· ----- 2 11" , 1'' .< .," COPPrn TEF ______ ..... _, 3 ,2" MALE x COPPER AOAPC"ER ... .. . .... _' 4 ,;(' Bt,,LL VAL VE W· fH :-/,'I.ND lf\1£R ____ __ 5 '7 YPE L COPPER ·--6. 2" , 1.5" FJRE HOSE flmNG 7 2" BALL VALVE \In~ PAOi.OC,-\'-11N-G -:j 8 2" x 2" ,c 1• C )( C li C T[[ ._j -~--F.-,-,~~~~-----' 9 'fi' rlOSE 818 OH lcSJ-c-CC=-·oc"=K ___ / ~ 10 Ir x J/4" C x_ MIP ADAPTE~ --~' 3.5 FEET ' I ij' MII-IIM\J'11<1:00IRED VERTICAL SEPARATION- 1<1:CLAll1:D W4TER lf<Rk':ATION MAIJ-l.lNE Ill' 51.EEVE y I-IOTE, ALL 1<1:CLAIMED W4TER IRRk':ATION PIPE AND SLEEVE& SHALL 6E FU~E AND LABELED A& SPECIFIED IN: ' '5TANDAAP SPECIFICATION& FOR PRIVATE lf<RIGATION SYSTEMS' 'CAAl..56AD RECLAMATla-1 m.l:& AND REGULATION& FOR CONSTJil.lCTION Cf RECLAIMED W4TER MAIN&' OCTOOER I~ ® POTABLE MAINLINE CROSSING ---,-------1 r 18' X 18' APPROVED RUJ WARNING SIGN SEE L-I FOR PRECISE DETAIL AND GRAPHICS &.92' .. ~. I ~-FRE DRILL PIPE I SIGN, SECURE WITH RECYCLED / i<IVET OR TAMPER PROO' 60L T WATER ~ n -1/-2' so,~ GAI.V. STEEL F06T. INSTALL POOT _, @ FLUSH WITH TOP Cf SIGN TOP Cf SIGN "' ~~ ~a TO BE 42 IN. ABOVE FINISH GRADE. --..1:1 • -ll'llllilillll NOTE· CON:-RACTOR TO PROVIDE &IGNS L\&11111111111 Mi il!DICATED ON KEY MIIP, LOCATE IN FIELD wIrn LANDSCAPE ARCHITECT • - ., • SLOPE TOP Cf FOOTl<u 10 DRAIN FINISH GRADE .------COMPACT 5UOO!<ADE L-----W,CRETE FOOTING· DIG Ill' X 8' D!A HOLE AND SECURE If CJi PO&T IN W,CRETE. (Q)R~CYCLED WATER SIGN \---~---------------------------t we FEET t' AXIHUH W,TROLLEI< ' I 1\===l,-1",e---MODEL, WIRELESS SOLAR SrNC 1 SENSOR, MOUNT UP TO 100' Fl<OM RECEIYER ___--SUI! A61.E POST, POLE, GUTTER 11:1.NT. •. J ........ ...-MOUNT IN LOCATION THAT MAXIMIZE& DIRECT 5UNLIGIII, OPEN TO RAllfALL , .., gJ AND OJI CJi &PRINKI.ER SPRAY PA"fTEl,l,I "'-4---~DEL, SOLAR SrNC i'WULE MOUNT LESS THAN /,' AWAY FRCi1 W,TROLLER '4--l---WIRELESS SOLAR SYNC RECElvi:I< MOUNTED ON THE WAL IIEXT TO THE \ ""-W,IROI.LER -'""\ '-- '-----.......,,~---W,DUIT FOR VAi.YE W,JROL W:RE AND SOI.AR SrNC C0111111NICATION \..---~"~-~L£'·~···~·-"~·-·'~"' WIRE CONTROLLER POlllER SOURCE @WIRELESS SOL, ,R SYNC SYSTEM WATER EFFICIENT LANDSCAPE WORKSHEET HYDRO ZONE INFORMATION TABLE 1-iYDROZONE Y.41.1£ IRRkiATICW FL.4NT FACTOR AREA CONTr20LL£R 1 1-irIJROZCNE ' DfSCRIFTIOII Cl~VIT' /1/:T!-iO[) ( CODf) r A,Efe4t:£HFFJ fl<AHSF) FAD I A ROTATORS R '1>.5 6':112 I 6 610 RETENTION AREAS R '1>.o 22"'5 I C NEWD~IF D '1),3 2¾11 ~ a' TOTAL L,4!,/[)SC,4Ff AREA FFX /<A If 6'1>.5 3456 ~, I~ 11'1>3 '1>.l 2'1>21.2 69!Zl '1>i FF X 1-iAII/: ----------- 4~1 ISlS 1363 IRRIGATION NOTES I. li<R~TICN FLANS-FIFll'-l::s, VAlvES, l-!EAD5, EiC. ARE DAA1N Dl~TICALL '1'. WITl<ACTOR 51-lALL ADJUST TO PROVIDE ADEQIJAlE COvERAGE M REQUIRED DUE ro MINOR &llE DRAW~ DISCREPANCIES. 2. IRRIGAllON FLAN 15 Dl~TIC. LOCAlE ALL MAINLINE&, EQIJIR1ENT AND APAJRTENANCE& WITHIN ~RTY LINES AND CiJTSIDE Cf PJBLIC RIGHT Cf WA 'I'. LOCAlE LATERAL& WITHII-I THE RO.W. ~ 'I' HRE IRRIGAT!mi THE RO.W. LANDSCAPE. AHLES LANDSCAPE ARCHITECTURE INC. P.O. Box 1503 Rancho Santa Fe, CA 92007 858-756-8963 MAXIMUM APPLIED WATER ALLOWANCE CALCULATIONS ESTIMATED TOTAL WATER USE 3. ca-lTl<ACTOR &1-!ALL OOARANlEE THE ENTIRE S'l'&l'El1 TO 6E FREE Cf DEFECTS Ill ~SHIP AND MATERIALS FOR A PERIOD Cf ONE YEAR~ FINAL ACCEPTANCE. Elo: ET FACTOR LANDSCAPE AREA /TOT Al}. CCN /fR FACTOR SFfC/.4/. LA,!,/[)SCAFE AfiEA, ADDITICWAL fl, 6f'EC!AL 4./ifA, FINISH GRADE---~ ' II ' b'RO!l'ID-----·---~ -VALVE OOX /clTH P-JRPLE UC!!. VAL VE TL0!'>01FV . SEE SPECS LI-IE FLUSHIN'.:i -;--~~r$~~~-I~• ~ \ ~ -::f--lllhl~U□f----.....J~ 1/2' PVC FEMALE-------n-;:=--:::;:=-:=--:::;:=-:::::;=:::\lli:'--1......sl~ ADAPTER C:-., MD PIPING · T-I BRICK 5UFFOl<TS ---~ . I .... "i,,~---_-1::::...::. /THREE! ...J.------::::---,~ ~~~1t s-· -----=,----------.., I 24' D!AMETER/ L ---J ____ ___ ,, I 44~ @7 11,416 @£,J t,;418 @.J ALL O/J/4NCE HAWA,!EWX0h2! [0.1 X LA + 0.3 X 5LA] = 311,483 GALLON&/'r'EAR 29.!46 CF/ YEAR @.6 7 AFI YfAR PVC MAINLII-E ,--RECYCL:'P WAlE~ wARNI~~ "AG REMOTE CONTROi. / I 12' x Ie VALVE BOX iw TH F\JRPLE UC) VALi'\: j \. i BRICK 5UFFORT /1-EA COl<NER/ ' \ I CU. FT. PEA GRAVEL 5UMP PRv M, F IPS COUPLING SCH.W UNION PVC OR POLY LATERAL UIE ESi!,11AT/:O TOTAL /114T/:R /.!SE ---------·----------· PERCENTAGE ALLOWANCE USED 1 64.6 PRESSURE LOSS CALCULATIONS &'l'&lfM I-IO, 8 5'1'61fMc;f11, 14.8 LAll:RAL 5'1'5TEM& PIPE FIFE 'C' FIFE SECTION FACTOR TrPE I w cl l0rll 2 w CL l0rll 3 w CL20rll 4 w CL 20rll 5 l!;'1) CL 20r21 6 l!;'1) CL 2"'11) , l!;'1) CL 200 & l!;'1) CL 200 9 l!;'1) CL 2"'11) I!) w CL 2"'11) A. TOTAL LA1£1<AL 5Y51fM L06Sl:6 Ml5Cel.U>£0J& L055ES 1111\TERMElER I' BACK FtOIII f'i<£'IENTER - 51'ATIC F'i<EOOiM, ~8 p,1 • t 384 llGL 11:TE!< 1:LEYATlc,ol, 68 PIPE FIPE ACCIJ1 SIZE LENt;T~ GPM 314 I& 0.4 314 I& ll 314 lr!I 21/) 314 20 2.8 314 2r21 3.6 I 20 4.4 I 20 52 I 2r21 f,1/) I I!) 3.8 l-i/2 20 14.8 MAINLINE PIPE TrPE PIPE 5,ZE PIPE LENt; TH c;PM Pl LOSS 0J 0J 0J r21J 02 r21J 0J 0J 02 r21J ll 4. CONTRACTOR &1-!ALL VERIFY WAlER Pfi£SSURE AT FDC Fl<IOR ro 6EGINNm ~ NOllF'l' LANDSCAPE ARCHllECT 1111EDIAlEL 'I' ~ AN'!' DISCREPANCIES. S. CONTRACTOR'S FOIi-iT Cf CONNECTION 51-lALL 6E DOILNSTREAM Cf WATEI< METER. FIFE 6E11l.EEN MElER AND BACK FLOW Pfi£VENlER SHALL 6E SCHEDULE K 1-IARD COFFER. 6. ELECTRICAL FDC. &1-!ALL 6E &FL.ICE TO 11'1> V PCllfR PROVIDED 6'1' OJ.HER ADJACENT TO WITROLLE~ LOCATION. 1. PRESSURE MAINLINES &1-!ALL 6E INSTALLED E~lEEI-I /!&'! INCHES DEEP AND LA lERALS TU.EL vE /12 ') INCI-IES DEEP. 6. CONTl<ACTOR &1-!ALL INSTALL T~T BLOCK& (I CUBIC FOOT Cf CONCRElE/ AT EACH CHANSE IN DIRECTION Cf Pfi£SSURE MAINLINE ':l. ffiESSIJRE lEST MAINLINE FOR 3 HOURS AT 125 F.S.I, 1-!AvE 11-15f'EClED AND AFFROVED 6'1' LAND. ARCHllECT, CIT'!' AND WAlER DISTRICT INSFECTORS F'l<IOR TO 6ACICflLL 10. LOCA1E AUTOMATIC VAi.YE& IN FLA&TIC YAL'vf BOXES. PROVIDE ONE OJBIC FOOL fx-PEA GRA'v1:1. UNDER EACH VAL'v1:. PROVIDE WAlE~ YALvE IDEl-lrlFICATICN TMI CN EACH VAL'v1:. 'BRAt-Cl' EACH LID BY l"ELT!mi STATION NIJ16ER CNTO EACH LID. IL PROVIDE '!1ro EXTRA WIRES FLU& ONE EXTRA CCMMCW WIRE, WITINUOJ5 ~ CONTROLLER TO RJRTHE&l VAlvE IN EACH CLU&lER. PROVIDE WATE~ IDEI-ITIFICATICN TMI ON EXTRA WIRES. 12. PROVIDE 6ALL YAlvE IN SEPARATE FLA&TIC BOX TO SEPARATE VAlvE CLU&TE!< FRCl'1 MAINLINE (HTHEI< &HO.IN ON THE FLANS OR NOT!. 13. LOCATE VAL 'v1: BOXES, ETC. Ill &HM FLANT!mi AREAS !NOT LAUN) WHERE FO&Sl6LE. 14. Fl.ACE QUICK COUPLER& NEARVALvE& AND SEPARATE~ MAINLINE WITH 6ALL VAL vE /HTHER &HO.IN ON FLANS OR NOT!. IS. LOCAlE SFRA'l' 1-!EADS 3 IN. MIN. FRG11 CURBS AND WA!.J<S AND 6 IN. MIN.~ allLDI~ AND WAI.LS. PROJECT NO.: 1216 w 0 <( _J ()_ 0:: ~ z U) <( 0: z 0 <( u. 2 -...J ...J 0.. <( w 0 0 0.. 0 <( <( () _J O'.l U) C/'J 0 ...J ...,,,-1-~-s• ITT FLUSH VALVE \__~ Cf'LIJ1BED TO PVC) I NT5 CD REMOTE CONTROL VALVE W/ DISC FILTER NTS SCH. 4" l-i/2' FITTING,& ""Cf LATl:7'AL& GATE VALi: - &r2I 14.8 r!IJ 11>2 NEGLlul!U 2.5 16. FOP UFS SHALL 6E USED IN THE RIGHT ~ WA 'I' AND WHEREVER WIT.IIN 10 FEET Cf AN'!' HARDSAPE, TIJl,f OR OTHER AREA UA.fRE PEDESTRIAN TRAFFIC MA'!' OCCUR 11. &FACE SFRA'l' 1-!EADS Cf &AME RADIU5 UN~ 'I' AL~ LAlERAL LINES. z <( ...J <( 0: <( ()_ I 0 [" FINISH GRADE ' ' "'z :,:: ,: z ~ "" £" _+--;~WARNING TAPE, CONTINUOUS ALONG LENGTH OF . b IN. ~.... V MAINLINE. CNE LAYER IMMEDIATELY AOOVE MAINLINE · · ' PIPE AND ONE LA,ER U IN. AOOVIE TOP OF MAINU~E. ' ' ' . "f._.+c,,~:.,,.. "'· \ .. . I V MAIN LINE-f'VC CLASS :ll&, 2 IN. OR LAR&ER, , . . , ·· · ·.. SCH. 41.il FOR 1-1/2 IN. OR 5MALLER SIZE , . \ 2.::: MIN. 18 IN. BELOW GRADE, MIN. 24 IN. BELOW PAVING \ CONTROLLER WIRES ~--LATERAL LINE• f'VC CLA&5 200 /EXCEPT SCH 4e FOR 1/2 IN. SIZE/ MIN. 12 IN. 6ELOIII GRADE, HIN. 16 IN. 6ELOIII PAVING @ IRRIGATION TRENCH PED=S'IRIAN PAVll.6--"'-, \ ' 1-EHICIU,R PAVll-l:i _r--FINliltl GRADE .. 0 ,1 <11 • • • -I I 1- U' ffil 11 1 I l~---~1·1 f~ I 1 111 I U'(MIN) / :I IJTG 11 ' I ~ :::fil_ SCIJ4D-----2// 11 11f 11 I 14 5I.EEv£ ~111~ r.l--~----t==--, ' • ' -11 I "~ SCll ll\!I @SLEEVE UNDER PAVING 5I.EEv£ ,~--&IDEIMLK CUfs6----, ,--METER BOX UV METER • -/1 24' _ . l , ___ -J f\ AFl'ROX. 8'_) i 12' MINR1UM POTABLE SERVICE LINE ---- ~ ' Ill)' M-II-IIMIJ1--TO_POT_ABLE __ MA.,lln< N ,,m ~ :All"ED W4TER IRRIGATION MAINLINE UV 51..EEVE - NOTE: VERTICAL CLEARANCE Cf ~• MINIMIJ1 IS M!!WATOl<Y 111,E,1 CROSS~ PATfl Cf A POTABLE l!IATER LINE. INSTALLATION Cf RECLAIMED l!IA~ lf<RIGATION MAINLINE 24' ~ FACE Cf 51DE111ALK WILL ~IDE Tl-IE NECE55ART' Ill)' flORIZONTPL c;LEAR,lJU ~ POTABLE MAINLII-E IN 5TRl:ET. MT& (Q) POTABLE SERVICE LINE CROSSING I 11~1 I I I , ! 1; [ l -----REMOTE CONTROL VAVE ✓ Wlrn DISC FILTER ,Al<D PlsV -,---PVC OR POLY Slf'FL Y HEADER • Tedil!ne STAI<! -ll--1-1-i---CONNECTION MALE ADAPTER l:e--jjH----Techl!no TU6ING LATERAL .....---AREA PERIMETER AIR/\' ACUIJ1 RELIEF -++---H----vALVE /PLUMBED ;o Tochl!no AT EAC!4 HIGH POINT BLANK Tec:Nlne TUBING li--+e----!CENTERED a; MOIJ,I[) OR BE,!1/ .+'r-+1-f-----PVC OR POLY EXHAUST HEADER / !-- I ~I~-PERIMETER LATERALS l' TO 4' FRa1 EDGE I = ~ PLUM6ED TO PVC OR POLY ILF -LINE FLU5HIN:; VALVE Q) SOAKER"'-'TlJBING LA YOUTchl!no 'END FEED' LAYOUT -------·- NT5 -------------------------------------------- FINISH GRADE b' ROlND I ll I VALYE OOX iPURPLE, AIR/ VACUUM 1:9 RELIEF VAi.VE :o 112' PVC COUPLING /TxT! t~• SCH. W ~SER - /LEN:;TH Mi REQUIRED) e~cK SUFFORT5 -□ /THREE/ □ 314' CRUSHED GRAVEL 5Ul1' es:: -_)-._ I I PVC FIFING AND FITTINGS ® AIRNACUUM RELIEF VALVE /PLUH6ED TO PVC) NT6 : >-------------------------------- CGlll1'0LVAI.YE I" HEAD Loe& 10 HIGie! 1-1:AP a TOTAL M19C. L055E& C. iOTAL&YSlfMLOSSl:5 D. DESIGN OFERATN:i Pl<E55UR!: E. Pi<E!iOO<E Rl:G!JIRl:P AT P.O.C. EXCc:55 /Df:FICITJ Pl<E551R EXCESS (Off/CIT) ffESS/JRf 0 Flt .433 r2I ah 20.8 4" 60.8 612 NOlE RELATIONSHIP TO Fl.ANT~, FARTIOJLARL 'I' Ill LINEAR ro-FIGURATICN5. COORDINAlE WHERE FLANT!mi AND IRR~TICN 1-fAD &FACll'-l::s CORRESFCW ro MAINTAIN UNI~ &FACll'-l::s 6ETU.EEI-I Fl.ANTS AND IRRIGATION. 16. PROVIDE MINIMUM 2 FT. SFRA'l' HEAD, 4 FT. LA~ RADIUS ROlOR. SEPARATION ~ CONTAIN!:~ FLANl IJ,ILE55 OlHERll!SE INDICAlED CN FLAN. IS. ADJUST HEADS TO PROVIDE EVEN COvERAGE AND AVOID THROJJ!mi WATER CN a!ILD~, WAI.LS AND FAYEMENT. UTILIZE MAlCHI~ SET VARIA6LE A~ NOULE& M NECE55AR!' ro AVOID OVER SFRA'l' . 20. ~VIDE LINE SIZE CHECK VAL vE FER FLAN AND M REQUIRED TO Pfi£vENT LOW HE,4D DRAINA:;E. 2L FLU&l-l ALL FIFE Fl<IOR TO IN&TALL!mi 1-!EADS. 22. &I-!~ RISERS TO 6E GRAY SCH. 130 F.VC, /NO 11!-lllE PVC/ &I-!~ RISE!sS TO 6E 16 IN. ABOVE FINISH GRADE, 6U66LERS 6 IN. lNLE55 INDICAlED 6'1' DETAIL 6ELOW GRADE IN WA TERll'-l::s TIJ6E. 23. 06TAIN AN IRRIGATICN COVERAGE AFFROVAL ~ LANDSCAPE AACHllECT PRIOR TO FLANlll'-l::s. CONT ACT LANDSCAPE ARCHITECT, CIT'!' AND WA TEI< DISTRICT INSFECTORS AT LEAST 12 HOURS Ill ADVANCE Cf IN5f'ECTION. 24. ffi?VIDE WATE!<f'ROCf' COLOR-CODED CONTROLLER CHARl Ill CONTROLLER CA61NET. REDUCE M NECE55AR'l' TO FIT, AND BE LEG16LE. f'ROVIDE ADDlllONAL COPY WIT.I IRR~TION RECORD DRAW~ AND MANUAL &U6MITTAL. 2S. f'ROORAl1 WITROLLER AND PROVIDE RECORD DRAW!mi AND WRITTEN SCHEDULE ro LANDSCAPE ARCHITECT /SEE 5f'ECIFICATION&). 26. ADJUST CONTROLLER ~5 ro WAlER AT A MORE CONSEFNATlvE RAlE AT Ml AND AGAIN AT 1S DAYS JJ=TER COHPLEllON Cf FLANlli'-1::s. 21. Ol!NER &1-!ALL AGAIN ADJUST WAlERI~ RAlE DOILN ONE YEAR~ cotfl.ETICN DA TE. 26. IRRIGATICN CONTRACTOR &1-!ALL MAII-ITAIN THE 5Y51'El1 FOR A PERIOD~ I-IINET'l' /'MJ) DAYS OR UNTIL FINAL FLANT!mi ACCEPTANCE (IJJl-llCHEvER 15 GREA TER.l AND OPERA lE M REQUIRED. 2':l. CONTl<ACTOR 51-'ALL ~YIPE 5U6MITTAL5 FER 5f'ECIFICATION&, INCLUDI~ OPERATION SCHEDULE AND />5 a!ILT DRAWi~. PRIOR TO FINAL ACCEPTANCE. SET ISSUE DATE INITIAL CD 31 JAN 13 FLAN cµEcK 5 MAR 13 FLAN cµECK 14 MAR 13 RUI PLAN cµEcK 21 MAR 13 SHEET: L.7 APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS . 'AS BUILT' DATE TITLE REVIEWED BY: INSPECTOR DATE ,--..,--.........,.-=============::::;-----i ~ CITY OF _c_A_R_LS_B_A_D~ I scE,ETS I ,-.....---+----+---------------+----+--+------+-·--L_l_J PLANNING DIVISION 1-------+----+--------------------------------------+----+---1 1-------+-----+---------------+--+----+--t----- DATE INffi/\L DATE INITIAL DATE INffi/\L LAND. AICf-l REVISION DESCRIPTION CITY APPRJVAL OTHER APPfOVAL IRRIGATION DETAIL& AND 5FECIFICATION5 PALOMAR PLACE PALOMAR AIRPORT ROAD CARLSBAD, CALIFORNIA I APPROVED< n-JI l::t ~l\._.;-\t PLANNlfll 4'-\''f.i'?, DATE OWN BY: PROJECT NO.• DRAWING NO.• Cl-l<D BY: RELD BK: SDP W-05(C:i) 411-,L ----->---------------~----~--------------