Loading...
HomeMy WebLinkAboutDWG 479-6L; CT 13-01; BUENA VISTA 11; 01-20Buer1a CaJr·lsbad, CA 92(J08 VICINITY MAP CITY OF OCEANSIDE HIGHWAY ?a PACIFIC OCEAN IQ .;J CY -1:i CITY OF VISTA 8 ;:".ty ('1_,, ,,,_.:.:R:.!;'.OA~r-----_,,.-I o?-1 ,,_ ,?-? -~ -- ·y - CITY OF ENCINITAS DHAWING INDEX: Sf-lEET TITLE OF MARCOS rdl.n LANDSCAPE DRAINAGE PLAN -LOT 1 MODEL LANDSCAPE LAYOUT PLAN -LOT 1 MODEL LANDSCAPE CONSTRUCTION PLAN LANDSCAPE CONSTRUCTION DETAILS LANDSCAPE /RR/GA T!ON PLAN LANDSCAPE /RR/GA T!ON NOTES LANDSCAPE !RR/GA TION DETAILS TREE PLANTING PLAN TREE PLANTING NOTES SHRUB ANO GROUNOCOVER PLANTING PLAN SHRUB ANO GROUNOCOVER PLANTING NOTES PLANTING DETAILS LANDSCAPE LIGHTING PLAN -LOT 1 MODEL DI RT DIAL TOLL FREE 1-800-422-4133 AT LEAST rwo DAYS BEFORE YOU D!G UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA LOCATION MAP .. : . ! ' ' . ,· ·-. . .• . f!.r,;(.c,o _ ~~~;Ale~, . ' . . Sf-lEET /\!UMBER 1 2 3 4 5 6 7 8-12 13 14 15 16 17-19 20 , NOTE: DECLARATION OF RESPONSIBLE CHARGE: I HEREBY DECLARE Tl-IA T I AM THE LICENSED DESIGNER OF WORK FDR T/-1/S PROJECT, THAT I I-IA 1/E EXERCISED RESPONSIBLE CHARGE 01/EF/ THE DESIGN OF T/-1/S PROJECT AS DEFINED IN SECTION 6 703 OF THE BUSINESS AND PROFESSIONS CODE AND Tl-IA T Tl-IE DESIGN IS CONSISTENT WIT/-/ CURRENT STANDARDS I UNDERSTAND Tl-IA T Tl-IE CI-IECK OF PROJECT DRAWINGS AND SPECIF/CATIONS BY Tl-IE CITY OF CARLSBAD AND SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL I-IEALT/-1 IS CONFINED TO A REVIEW ONLY AND DOE:S NOT RELIEVE ME, AS Tl-IE LICENSED DESIGNER OF WORK, OF MY RESPONSIBILITIES FOF/ PROJECT DESIGN. T/-/ESE PLANS I-IA 1/E BEEN PFiEPAF/ED IN SUBSTANTIAL CONF0FIMANCE WIT/-/ Tl-IE APPFiOVED LANDSCAPE CONCEPT PLAN, WATER CONSER I/A TI0N PLAN, FIF/E PF/OTECTION PLAN, AND ALL CONDITIONS OF APPF/01/AL FiELA TED TO LANDSCAPING BY: C/-/F/IST0P/-/UI M. BFi0WN, LANDSCAPE AF/Cl-1/TECT PHONE NO.· ( ..li58....) fils.c--~-"-'-'-''-------~ F/ECISTRA TION NO: CA FiLA //5 719 EXPIFiA TION DA TE: S[PTEMBEFi 30, 2015 WATER EFFICIENT LANDSCAPE DECLARATION: I AM FAMILIAF/ WITH Tl-IE F/E0U!FiEMENTS FOF/ LANDSCAPE ANO /F/F//GA TI0N PLANS CONTAINED IN Tl-IE CITY OF CAF/LSBAD 's LANDSCAPE MANUAL & WATER EFFICIENT LANDSCAPE F/ECULA TIONS. I I-IA VE PFiEPARED THIS PLAN IN COMPLIANCE WIT/-/ n/OSE REGULATIONS AND Tl-IE LANDSCAPE MANUAL. I CERTIFY Tl-IA T Tl-IE PLAN IMPLEMENTS Tl-JOSE Fi[GULA TIONS TO PROVIDE EFFICIENT USE DF WA TEFi. BY: C/-IRISTOPHER M. BROWN, LANDSCAPE ARCHITECT PHONE NO ( ...B..5fi..) n,b,--,,.5'1.c-,,.·'ic.15,.ct CL_ ____ _ Fl[CISTFIATION NO: CA FILA /15719 [XPIF<A TION DATE: S[PTEMBEFI JO 2015 BACKFLOW PREVENTER TESTING: ALL /RR/CATION BACKFLOW PR[I/ENTERS S/-/ALL 8[ TESTED BY A CERTIFIED TESTEri ANO RESULTS MUST BE Gil/EN TO THE CITY AND fl-IE CARLSBAD MUNICIPAL WATER DISTRICT. PIPE BETWEEN Tl-IE METU/ AND BACKFLOW PREI/ENTUI SHALL 8[ "SC'/-l[DULE K /-/ARD COPPUi'' APPF/01/ED CONTRACT DACKFLOW TESTERS CAN BE FOUND ON Tl-IE CITY WEB SITE AT: HTTP:/ /WW'//. CARLSBADCA GOV /SEFiVICES/DEPAR fMEN TS/WAFER/DOCUMENTS/RECYCLED WA TERBACKFLOWTESfERLIST. PDF FOR RECYCLED 0Fi HTTP: //WW'//. CARLSBADCA.COV /SERI//C[S/DEPAR TMENTS/WA TER/DOCUMENTS/WA TERBACKFLOWTESTUILIST.PDF FOR POTABLE OR CALL (760) 438-2722. INSPECTION PROCEDURES: INSP[Cf/ON PFi0C[DUR[S: INSPECTION OF ff/[ PFi0JECT S/-/ALL 8[ PERFORMED BY Tl-IE LANDSCAPE Ar/C/-1/TECT OF WORK, OR 1-115 DESIGN A TED AGENT. REFER TO THE SPECIF/CATIONS FOTI Tl-IE SCHEDULE OF FiEQU/FiED INSPECTIONS AND REQUIRED SUBMITTALS. FOLLOWING COMPLETION OF Tl-IE WORK, Tl-/[ LANDSCAPE AriCl-1/TECT OF fl-IE WOFIK WILL CERTIFY THAT Tl-IE INSTALLATION HAS BEEN COMPLETED BY SUBMITFINC Tl-IE "CUITIFICA TION OF COMPLETION" FOFiltl. A REQUEST FOR A FINAL LANDSCAPE INSPECTION BY Tl-/[ CITY MUST ALSO BE MADE BY CALLING THE INSPECIION R[OUEST LINE. "CUITIFICA TION OF COMPLETION" FORM FAX TO: (760) 944-8943. LANDSCAPE INSPECTION FiEQU[ST PHONE LIN[: (760) 602-4602. PRIOR TO BEGINNING LANDSCAPE WORK: THE CONTFiACTOFi SI-IALl CONTACT Tl-IE DESIGNEFi OF WORK PRIOR TO BEGINNING LANDSCAPE WORK AND THE DESIGNER OF WORK SHALL F/[1/l[W T/-1[ PFiOJECT UTILITY LOCATIONS AND REVISE PLANS ACCORDINGLY TO FULLY SCFl[EN ALL UTILITIES FROM I/IOI AND PROTECT ALL UTILITIES (ABOVE & BELOW Cf/ADE) FROM INVASIVE PLANT CROWTl-1 AND eooT~ J. APPROV[O F'OR /RR/GA TIO/\/ A/\/O PLA/\/ TING ONL Y1 INCLUDING PR[C/S[ LOCATION OF P LA /\I Tl/\/ G AR[A. 11 AS BUILT 11 A SEPAf!A ff CITY (i[I/IEW AND APPROVAL IS REQUIRED FOR ANY PORTIONS OF THESE PLANS REQUIRING A f,CE EXP. DATE BUILDING PERMIT. CITY APPROVAL OF TI-IES[ PLANS IS FOTI LANDSCAPE PLANTING AND /FiR/GA TI0N ONLY. RE\/IE',IED BY, INSPECT□r, DATE 12.10.13 CB /1\ REI/IS/ON I SH~ET I CITY OF' CAf~LSBAD SHEETS 01.13.14 CB /, ';\ REVISION 01.21.14 CB I I\ REVISION PLANNING DIVISION 20 LAND$CAPE: IMPROVEMENT PLANS FOR --BUENA VISTA 11 ,,.osoAPE-~ TITLE SHEET ~~ ¾ C, t$ ~ ¾ APPROVED: /'t:):_ $! -0-L--r:-~ JL..Q~-Z·w·i-f' _, __, .>;I J< . \ Tf """'' ''i---. PLANNING iftA~f • °"' DWN BY: CB I PROJECT NO I 04f9~6L0 ~.... .... '<-'\::'' DATE INI rlAL DATE IN! TIAL DATE INITIAL CHKD BY: <' 0 REVISION DESCRIPTION CT 13-01 ~-~ <;.A.\.\'c DESIGNER OF WORK OTHER APPf<OVAL Cl fY APPROVAL RVWD BY: HOA MAINTENANCE ACCESS GATE "'< « "'< 0 "'< ~a • ~ • \ ~· I, I I PAVING EDGE (TYP.) PLANTING EDGE (TYP.) RETAINING WALL (TYP.) DRAINAGE LINE, TO BE CONFIRMED BY CIVIL ENGINEER (TYP.) STORM DRAIN (TYP.) I I I I I I I I I I I I I I I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER." • I / / • • • • I I I I I I I I I I I I I "'< « / / / I I I I • I I I • /' / I • • I I I I I I • FENCELINE (TYP.) "'< • El • 0 C I I \_ I ,-\- ,L-_\,-----1-•- "'< ---- • -- \ EDGE OF TURFBLOCK PAVING (TYP.) • • ----------- • --_sn- GRADING & DRAINAGE LEGEND SYMBOL DESCRIPTION ATRIUM DRAIN IN PLANTER OR TURF AREA SURFACE DRAIN IN PAVING 2% FLOW ARROW 'INFORMATION IS PROVIDED AS A SCHEMATIC REFERENCE. FINAL GRADING AND DRAINAGE CALCULATIONS TO BE COMPLETED BY CIVIL ENGINEER 8 0 8 16 24 ' -----' --------' • 0 \ \ \ FLAGSTONE SET IN PLANTING AREA (TYP.) I <J t, <J • \ I \ \ \ ,1 t, <J ·L • <J ,1 <J t, t, <J ,1L_ ,1 t, /· < I < L L . /. C CJ 0 L -u \ < h rn < L < . r TREE SYMBOLS • PROPOSED TREE NOTE WELL GRADING GENERAL NOTES: 1. ALL WORK SHALL CONFORM TO ALL CITY AND OTHER GOVERNING AGENCIES' REGULATIONS FOR LANDSCAPE CONSTRUCTION. CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS, INSPECTIONS AND APPROVALS REQUIRED FOR THIS WORK. 2. COMPLY WITH ALL GEOTECHNICAL RECOMMENDATIONS. NOTIFY THE GEOTECHNICAL ENGINEER 48 HOURS IN ADVANCE FOR ANY REQUIRED INSPECTIONS. 3. REFER TO ARCHITECTURAL DRAWINGS BY SENNIKOFF ARCHITECTS, 5500 EAST 2ND STREET, STE 2, LONG BEACH, CA 90803. 4. REFER TO CIVIL ENGINEER'S DRAWINGS FOR DRAINAGE PIPE SIZING AND CALCULATIONS. ENGINEER TO BE LUNDSTROM ENGINEERING & SURVEYING, 5333 MISSION CENTER ROAD, SAN DIEGO, CA 92108 . 5. REFER TO THE BOUNDARY AND TOPOGRAPHIC SURVEY, BY LUNDSTROM ENGINEERING & SURVEYING, 5333 MISSION CENTER ROAD, SAN DIEGO, CA 92108 .. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE LAYOUT OF THE PROJECT, FOR ESTABLISHING ALL REFERENCE POINTS AND LINES SET FOR CONSTRUCTION, FOR CERTIFICATION OF FINISH GRADES AS SHOWN ON THE LANDSCAPE DRAWINGS, AND TO MATCH EXISTING SURFACES WHERE APPLICABLE. IF REQUIRED, THE CONTRACTOR SHALL EMPLOY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR TO DELINEATE HORIZONTAL DIMENSIONS AND SET ELEVATIONS IN ORDER TO CONFORM TO CONSTRUCTION DOCUMENTS. 7. CONTRACTOR SHALL VISIT THE SITE, VERIFY EXISTING GRADES, BECOME FAMILIAR WITH SITE AND SOIL CONDITIONS, AND COORDINATE GRADING AND DRAINAGE WORK WITH ALL SUBCONTRACTORS IN ORDER TO PREVENT CONSTRUCTION DISRUPTION OR INTERFERENCE WITH OTHER TRADES. 8. IF THERE ARE ANY DISCREPANCIES BETWEEN THE ACTUAL ON SITE CONDITIONS AND THESE PLANS, THE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT PRIOR TO BEGINNING CONSTRUCTION. 9. VERIFY LOCATION OF ALL UNDERGROUND UTILITIES AND SERVICES PRIOR TO ANY EXCAVATION. CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR ALL DAMAGE CAUSED BY FAILURE TO DO SO. 10. EROSION AND SILTATION PREVENTATIVE MEASURES SHALL BE IMPLEMENTED AS REQUIRED BY THE APPROPRIATE GOVERNMENTAL AUTHORITY. 11. CONTRACTOR SHALL KEEP SOIL WATERED SUFFICIENTLY TO ELIMINATE DUST NUISANCE. 12. REPORT ALL CONDITIONS WHICH PREVENT PROPER EXECUTION OF THIS WORK TO THE GENERAL CONTRACTOR. 13. PROTECT ALL STRUCTURES, UNDERGROUND UTILITIES AND EXISTING PLANT MATERIAL INDICATED TO REMAIN ON THE SITE FROM DAMAGE DURING GRADING WORK. CONTACT THE ARBO RIST FOR PLANT MATERIALJTREE PROTECTION RECOMMENDATIONS. 14. NO BRANCHES, LIMBS OR ROOTS OF ANY PLANT MATERIAL ARE TO BE CUT OR PRUNED WITHOUT PERMISSION FROM THE ARBORIST. 15. ROUTING AND LOCATION OF DRAIN LINES INDICATED ON DRAWINGS ARE DIAGRAMMATIC. AVOID CONFLICT WITH OTHER UNDERGROUND UTILITIES. WHEREVER POSSIBLE, AVOID PLACING DRAIN LINES IN THE ROOT ZONES OF EXISTING OR PROPOSED TREES. 16. ALL PLANTING AREAS ARE TO BE GRADED AT A MINIMUM OF TWO (2) PERCENT, UNLESS OTHERWISE NOTED ON PLANS. FINISH GRADES SHALL BE ONE (1) INCH BELOW ADJACENT PAVING IN LAWN AREAS, AND TWO (2) INCHES BELOW ADJACENT PAVING IN SHRUB/GROUND COVER AREAS. 17. SET ALL HARDSCAPE AREA GRATES TO FINISHED PAVING SURFACE. SET ALL PLANTING AREA GRATES TO FINISHED GRADE AS INDICATED ON PLANS. PROPOSED GRADES SHOWN ON PLANS ARE THE FINAL GRADES UNLESS OTHERWISE NOTED. 18. SURFACE DRAINAGE SHALL BE DIRECTED AS INDICATED ON THE DRAWINGS, FINISH SURFACE AREAS ADJACENT TO BUILDING OR PAVING SHALL SLOPE AWAY FROM THE STRUCTURES. CONTRACTOR SHALL TAKE ALL NECESSARY STEPS TO ASSURE THAT FINISHED FLOW LINES DRAIN FREELY TO DRAINAGE INLETS. AP PRO VfO FOR /RR/GA TIO/\/ AND PLAN TING ONLY, I/\/CLUO//\/G PRfC/Sf LOCA T/ON OF PLANTI/\/G AREA. RCE____ EXP. ____ _ DATE NO EXCAVATION OF ANY KIND IS TO OCCUR ANYWHERE ON SITE WITHOUT FIRST VERIFYING THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES. REV IEVED BY, JNSPECT□r, DATE f-"'~'-'~._"; ~"'-:'-'1+-.,,.6~,,___~"---"'~~=-'~"--': ~"'·:g"-'~'---------------1-----1------f----+------I I SH ~ET I C IT y O F C AR LS BAD SHEETS 01. 21. 14 CB f/EVI SION ==='--'====::::::P:=L:::::A:::::N::::N:::::IN::::G:::::::::D:::I:::V::::I s=· I:=□:::N====-==2=D==' f----1-----+-----------------l---l------+---l----l LANDSCAPE IMPROVEMENT PLANS FOR: BUENA VISTA 11 LANDSCAPE DRAINAGE PLAN -MODEL APPROVED: f----1-----+-----------------l----l------+-----+---I PLANNING f-ccD-cA=cTEc---11-IN~IT~IA7L+-------------------l--D-AT-E--I----IN-IT-IA-L----J.--0-A-.r-E____jL_---I :::;D:::¥::IN==B;::Y=:===c::8;=::::;-;===p=R=O=J=E=C=T=N=O=. ==;-;:::D=R=A=~=/IN=G=N=O::::. INlflAL CHKD BY:~~ CT 13 01 DESIGNER OF WORK REVISIO~I DESCF,IPTION OTHER APPROVAL CITY APPROVAL RI/WD BY: -4 79-6L i HOA MAINTENANCE ACCESS GATE PAVING EDGE (TYP.) PLANTING EDGE (TYP.) SITE DRAINAGE PER CIVIL PLANS (TYP) RETAINING WALL (TYP.) I I I I I I I I I I I I \ I I I I I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER." I I I I • / / • I \ • \ \ \ I \ • \ \ • • J__ I I \ F~ -:: i\1.-=---I \ \ _\ \ \ \.-- 1 \ • \ \ I \ FENCELINE (TYP.) • • ------ C EDGE OF TURFBLOCK PAVING (TYP.) • • --- SlURMWATER l3MP PER Cl'/IL DRAWINGS ) 6• z.o·~~ ?· jl \ - • • N,.iGN PJ'..1/lNG W\TH EDGE Of WALL ---.,_ n STAINED CE. SELECTED coLOR rooa uAAV'I\NGS MPPE.RCl'I\L 510RMWA1E.RB - 8 4 0 8 16 I~__,~ i I SCALE: 1/8"=1'-0" r 24 1 • • 6'-9" fENCE 1Yf', PS oT1A , PA coNCRETE- s1 ... 1NED SE. SELECTED COLOR yo . ~ ------ 12.10.13 01.13.14 01.21.14 J'-NOSCAp€" '~~~ •? "'" ~ ~, • . \ '#- <Jl),,~ 't: .., .. ' DATE l's, -, ~ 0£: Gll\.\fO DESIGNER .... ___ <1 <] [,, • CB CB CB L', <] [,, [,, <1 . <1/ L', < [,, [,, I L <1 <\ L < I < L L L < \ -CJ 0 -0 \ h • rn TREE SYMBOLS • PROPOSED TREE NOTE WELL: LANDSCAPE LAYOUT GENERAL NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12 13. 14. 15. 16. 17. ALL WORK SHALL CONFORM TO ALL CITY AND OTHER GOVERNING AGENCIES' REGULATIONS FOR LANDSCAPE CONSTRUCTION. CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS, INSPECTIONS AND APPROVALS REQUIRED FOR THIS WORK. COMPLY WITH ALL GEOTECHNICAL RECOMMENDATIONS. NOTIFY THE GEOTECHNICAL ENGINEER 48 HOURS IN ADVANCE FOR ANY REQUIRED INSPECTIONS. REFER TO ARCHITECTURAL DRAWINGS BY SENNIKOFF ARCHITECTS, 5500 EAST 2ND STREET, STE 2, LONG BEACH, CA 90803. REFER TO CIVIL ENGINEER'S DRAWINGS FOR DRAINAGE PIPE SIZING AND CALCULATIONS. ENGINEER TO BE LUNDSTROM ENGINEERING & SURVEYING, 5333 MISSION CENTER ROAD, SAN OIEGO, CA 92108. REFER TO THE BOUNDARY AND TOPOGRAPHIC SURVEY, BY LUNDSTROM ENGINEERING & SURVEYING, 5333 MISSION CENTER ROAD, SAN OIEGO, CA 92108. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE LAYOUT OF THE PROJECT, FOR ESTABLISHING ALL REFERENCE POINTS AND LINES SET FOR CONSTRUCTION, FOR CERTIFICATION OF FINISH GRADES AS SHOWN ON THE LANDSCAPE DRAWINGS, AND TO MATCH EXISTING SURFACES WHERE APPLICABLE. IF REQUIRED, THE CONTRACTOR SHALL EMPLOY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR TO DELINEATE HORIZONTAL DIMENSIONS AND SET ELEVATIONS IN ORDER TO CONFORM TO CONSTRUCTION DOCUMENTS. CONTRACTOR SHALL VISIT THE SITE, VERIFY EXISTING GRADES, BECOME FAMILIAR WITH SITE AND SOIL CONDITIONS, AND COORDINATE LANDSCAPE LAYOUT AND CONSTRUCTION WORK WITH ALL SUBCONTRACTORS IN ORDER TO PREVENT CONSTRUCTION DISRUPTION OR INTERFERENCE WITH OTHER TRADES. IF THERE ARE ANY DISCREPANCIES BETWEEN THE ACTUAL ON SITE CONDITIONS AND THESE PLANS, THE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT PRIOR TO BEGINNING CONSTRUCTION. VERIFY LOCATION OF ALL UNDERGROUND UTILITIES AND SERVICES PRIOR TO ANY EXCAVATION. CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR ALL DAMAGE CAUSED BY FAILURE TO DO SO. THE LANDSCAPE ARCHITECT IS TO REVIEW AND APPROVE ALL STAKING IN THE FIELD BEFORE THE BEGINNING OF CONSTRUCTION. INDICATED DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED MEASUREMENTS ON PLANS. REPORT ALL CONDITIONS WHICH PREVENT PROPER EXECUTION OF THIS WORK TO THE GENERAL CONTRACTOR. PROTECT ALL STRUCTURES, UNDERGROUND UTILITIES AND EXISTING PLANT MATERIAL INDICATED TO REMAIN ON THE SITE FROM DAMAGE DURING LANDSCAPE LAYOUT AND CONSTRUCTION WORK. CONTACT THE ARBORIST FOR PLANT MATERIAi/TREE PROTECTION RECOMMENDATIONS. NO BRANCHES, LIMBS OR ROOTS OF ANY PLANT MATERIAL ARE TO BE CUT OR PRUNED WITHOUT PERMISSION FROM AN ARBORIST. PRIOR TO ANY INSTALLATION, SAMPLES OF ALL FINISH MATERIALS ARE TO BE PREPARED BY THE CONTRACTOR FOR APPROVAL BY THE CLIENT AND LANDSCAPE ARCHITECT. EROSION AND SILTATION PREVENTATIVE MEASURES SHALL BE IMPLEMENTED AND MAINTAINED AS REQUIRED BY THE APPROPRIATE GOVERNMENTAL AUTHORITY. CONTRACTOR SHALL KEEP SOIL WATERED SUFFICIENTLY TO ELIMINATE DUST NUISANCE. APPROVED /Fs;:R/GA TIO/\/ AND OA/L Y, INCLUOIAIG FOR PLAAI TING PR[C/S[ LOCATION OF PLANTING AREA. 11 AS BUILT 11 RCE EXP. DATE NO EXCAVATION OF ANY KIND IS TO OCCUR ANYWHERE ON SITE WITHOUT FIRST VERIFYING THE LOCATIONS OF REVIE\./ED BY: EXISTING UNDERGROUND UTILITIES. INSPECTOR DATE /1\ f!EVISION CT:] CITY OF CAfiLSBAD SHEETS 1A REVISION ~ REVISION . PLANNING DJ V 1 SI□N 20 LANDSCAPE: IMPROVE:ME:NT PLANS F'OR: BUENA VISTA 11 LANDSCAPE LAYOUT PLAN -LDT 1 MODEL : PLANNING I APPROVED: /t_i\ k-~1_.;-tt '2-C..-i:t DWN BY: __[B__ PFWJECT NO . DRAWING NO INITIAL DATE INITIAL DATE INITIAL CHKD BY: OF '//ORK REVISION DESCRIPTION 0 [HER APPROVAL CITY APPfWVAL RVWD BY: CT 13-01 479-6L I ,---WOOD GATE ACCESS FOR HOA MAINTENANCE CREW -SEE DETAIL FLAGSTONE PATH FOR HOA ACCESS (TYP.) -SEE DETAIL • LANDSCAPE CONSTRUCTION GENERAL NOTES: 1. ALL WORK SHALL CONFORM TO ALL CITY AND OTHER GOVERNING AGENCIES' REGULATIONS FOR LANDSCAPE CONSTRUCTION. CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS, INSPECTIONS AND APPROVALS REQUIRED FOR THIS WORK 2. COMPLY WITH ALL GEOTECHNICAL RECOMMENDATIONS. NOTIFY THE GEOTECHNICAL ENGINEER 48 HOURS IN ADVANCE FOR ANY REQUIRED INSPECTIONS. 3. REFER TO ARCHITECTURAL DRAWINGS BY SENNIKOFF ARCHITECTS, 5500 EAST 2ND STREET, STE 2, LONG BEACH, CA 90803. 4. REFER TO CIVIL ENGINEER'S DRAWINGS FOR DRAINAGE PIPE SIZING AND CALCULATIONS. ENGINEER TO BE LUNDSTROM ENGINEERING & SURVEYING, 5333 MISSION CENTER ROAD, SAN DIEGO, CA 92108. 5. REFER TO THE BOUNDARY AND TOPOGRAPHIC SURVEY, BY LUNDSTROM ENGINEERING & SURVEYING, 5333 MISSION CENTER ROAD, SAN DIEGO, CA 92108. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE LAYOUT OF THE PROJECT, FOR ESTABLISHING ALL REFERENCE POINTS AND LINES SET FOR CONSTRUCTION, FOR CERTIFICATION OF FINISH GRADES AS SHOWN ON THE LANDSCAPE DRAWINGS, AND TO MATCH EXISTING SURFACES WHERE APPLICABLE. IF REQUIRED, THE CONTRACTOR SHALL EMPLOY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR TO DELINEATE HORIZONTAL DIMENSIONS AND SET ELEVATIONS IN ORDER TO CONFORM TO CONSTRUCTION DOCUMENTS. 7. CONTRACTOR SHALL VISIT THE SITE, VERIFY EXISTING GRADES, BECOME FAMILIAR WITH SITE AND SOIL CONDITIONS, AND COORDINATE LANDSCAPE CONSTRUCTION WORK WITH ALL SUBCONTRACTORS IN ORDER TO PREVENT CONSTRUCTION DISRUPTION OR INTERFERENCE WITH OTHER TRADES 8. IF THERE ARE ANY DISCREPANCIES BETWEEN THE ACTUAL ON SITE CONDITIONS AND THESE PLANS, THE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT PRIOR TO BEGINNING CONSTRUCTION. 9. VERIFY LOCATION OF ALL UNDERGROUND UTILITIES AND SERVICES PRIOR TO ANY EXCAVATION. CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR ALL DAMAGE CAUSED BY FAILURE TO DO SO. 10. THE LANDSCAPE ARCHITECT IS TO REVIEW AND APPROVE ALL STAKING IN THE FIELD BEFORE THE BEGINNING OF CONSTRUCTION. 11. INDICATED DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED MEASUREMENTS ON PLANS. 12. REPORT ALL CONDITIONS WHICH PREVENT PROPER EXECUTION OF THIS WORK TO THE GENERAL CONTRACTOR. 13. PROTECT ALL STRUCTURES, UNDERGROUND UTILITIES AND EXISTING PLANT MATERIAL INDICATED TO REMAIN ON THE SITE FROM DAMAGE DURING LANDSCAPE CONSTRUCTION WORK. CONTACT THE ARBO RIST FOR PLANT MATERIAL/TREE PROTECTION RECOMMENDATIONS. 14. NO BRANCHES, LIMBS OR ROOTS OF ANY PLANT MATERIAL ARE TO BE CUT OR PRUNED WITHOUT PERMISSION FROM THE $$ARBORIST$$. 15. PRIOR TO ANY INSTALLATION, SAMPLES OF ALL FINISH MATERIALS ARE TO BE PREPARED BY THE CONTRACTOR FOR APPROVAL BY THE CLIENT AND LANDSCAPE ARCHITECT 16. EROSION AND SILTATION PREVENTATIVE MEASURES SHALL BE IMPLEMENTED AND MAINTAINED AS REQUIRED BY THE APPROPRIATE GOVERNMENTAL AUTHORITY. 17. CONTRACTOR SHALL KEEP SOIL WATERED SUFFICIENTLY TO ELIMINATE DUST NUISANCE I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER." • ~ Cl -' . • LOT 1 LOT 2 r_ LOT 4 \ \ \ \ \ \ \ \ \ \ \ \ • \ \ • l \ \ \ \ \ \,,--,-' \ / \ \ \ \ \ ,,\ \ PERMALOC ALUMINUM EDGING TO BE INSTALLED ~-BETWEEN PRIVATE AND HOA MAINTAINED PLANTING AREAS (TYP.) -SEE DETAIL LOT 7 / LOT 9 LOT 6 /✓ \ \ ,,,,,.,,,,... /f \<\ .,...,...,...,..-✓✓ \ -✓ \ / / ( \ \ \ ,.\ ' ~-WOODGATE (TYP.), SEE DETAIL f0 ------WATER SERVICE (TYP.) -----SEWER SERVICE (TYP.) -,~-----~ ~--DRAINAGE (TYP.) -SEE CIVIL PLAN ~-RETAINING WALL (TYP.) SUBDIVISION BOUNDARY -----WATER PIPELINE EASEMENT EXISTING ROAD RIGHT-OF-WAY EASEMENT PROPOSED ROAD RIGHT-OF-WAY ~--EASEMENT ,---VEHICULAR SIGHT TRIANGLE (TYP.) ~-WOOD FENCE (TYP.) -SEE DETAIL CONSTRUCTION LEGEND INSTALLATION OF GREENFIX AMERICA'S WS05B BIODEGRADABLE ORGANIC NET STRAW MAT PER MANUFACTURER'S INSTALLATION AND FASTENING GUIDELINES *SEE CIVIL PLANS FOR SITE PAVING INFORMATION *SEE LL-1 FOR MODEL PAVING INFORMATION LOT 5 ~ SDG&E EASEMENT TREE SYMBOLS APPROVED FOR !RR/GA T!ON ANO PLAN TING 0/\/L Y, I/\/CLUOI/\/G PR[C/S[ LOCA T!ON OF PLANTING AR[A. OVERFLOW DRAIN PIPES FROM ~-- BIORETENTION BASINS -SEE CIVIL PLANS PLANTED BIORETENTION BASINS (TYP.) -SEE CIVIL PLANS RETAINING WALL (TYP.) -SEE CIVIL PLANS ii 20 0 20 40 60 ' N SCALE: 1 "=20' ~ ~-PROPOSED HOA MAINTENANCE EASEMENT • PROPOSED TREE '1 AS BUILT 1' NOTE WELL: DATE "---PROPOSED 30' PUBLIC UTILITY EASEMENT NO EXCAVATION OF ANY KIND IS TO OCCUR ANYWHERE ON SITE WITHOUT FIRST VERIFYING THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES. RCE ___ EXP, ___ _ ;;~,;;, \) \. -------,f <:; -9c, ,,., ~ IJ ~ , ·o ·-' •-t ~ ," ,, . ,_ '?- .,o OF o ;.\.•' -·- REVIE\JED BY, INSPECT □r< DATE 12.10.13 CB l REVISION 01.13.14 CB REVISION 01.21.14 CB REVISION ~~="----------+---+-----+--1---11 SH!ET I CITY OF1 CJ\f{LSBJ\D ~ PLANNING D!\/ISI □N ~ ~l=,A=N==o==s==cA:'._P'.:::E::::,,=1=M==P=r,=o=v==E=M=E:=N,::::l'=P==L=A=N::::8;::::::f'=O=R=: ===.'::===~ BUENA VISTA 11 LANDSCAPE CONSTRUCTION PLAN i~--+----+--------------+---+----+---+---1 I-AP_P_R_ov_E_o_, _/~_'-"-<'..,_-_(~G~t--~~=l...o~1:t,~-- PLANNINC DATE INITIAL REVISION DESCRIPTION DESIGNER OF '//ORK DATE INITIAL DArE INlflAL OTHER APPfWI/AL cnY APPROVAL OWN BY: CHKD BY: __ _ RVWD BY: CB PROJECT NO. CT 13-01 DF,AWINC NO. 479-6L ~-2X8CAP --2X6 PLANT ON I -~ 1 X 6 SIDING 4 X4 POST ~ 0 2X4 ' <D STRINGER i I I ~-----4 X 4 PRESSURE TREATED REDWOOD POST@ 8' O.C. ~-----2 X 8 CEDAR CAP / ~----2 X 6 CEDAR PLANT ON ~s-+----1 X 6 CEDAR SIDING 1~-f--t----~ 2 X 4 REDWOOD STRINGER ~--FINISH GRADE ~--2 X 6 CEDAR PLANT ON --2"CLEAR ~~~r SECTION I ELEV AT!ON 0 WOOD FENCE 1/2" MAX ' 30"/ I /// , ✓ I~• ~~-. - I.' 1}; 1\ / I f I I I I I I I I V \ I I / v/ --=--=-_,,L--~ I ' , ELEVATION ~)WOODGATE I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER." ,, I ~ ~/ ," / / ~ -/_ - V I LATCH ASS EMBLY 2 X B CEDAR CAP 2 X 6 CEDAR PLANT ON 1 X 6 CEDAR SIDING 2 X 4 REDWOOD STRINGER 6" SELF-CLOSING HINGE (TYP.) FINISH GRADE 2 X 6 CEDAR PLANT ON 2" CLEAR NOTE: N.T.S. ALL METAL TO BE ZINC PLATED OR APPROVED EQUAL, CLEAN OF FREE PAINT AND STAIN. ALL GATE MEMBERS TO BE GLUED AND NAILED N.T.S. CMU BLOCK RETAINING WALL INFORMATION WALLS TO BE BUILT PER CIVIL ENGINEER'S DRAWINGS UTILIZING SPLIT FACE 8X8X16 CMU BLOCK WITH A 2X10X16 PAVER WALL CAP. COLOR TO BE LA PAZ. CD CMUWALL 4". ~-------------SIZE VARIES --SEE LANDSCAPE LAYOUT PLAN ~------------MORNING MIST TUMBLED QUARTZITE FLAGSTONE -CONTACT SOUTHWEST BOULDER ~-FINISH GRADE: 2" BELOW PAVING IN GROUNDCOVER f' 1" BELOW PAVING IN LAWN AREAS -f--1\"T02"THICK • • d ~r 0 4 --3" TO 4" CONCRETE/MORTAR • . • • 1111, I SUBBASE UNDER EACH STONE -' " · .• .,i'' II!§, TRIM TO EDGE OF STONE ------------------{· I@1lmllirr~Jlimllifr1r1_'rri!MmLUml!lm~m[!]ml!lm[!]m[!]ITTg;Tf i1rrn!l;m!lim!IiITT!!!ITT~:~~~I COM PAC Tl O N O F S U BG RA DE PER I=ffi=ffi=l.fEffi=!TETT1--[!]inffi=lTEillnl!l/rrl!!rnflEffi=ffi=~trJlirriffi=ffi=JlE~l.fEITT GEOTECHNICAL ENGINEER'S 1IJli11l!lml!lffi!!lffi!liif Jlirr~f cml!lm_l!lif ikmJcm1=rrJllssl I l~~Ekff EimIJlmI!lif lljlf r!!!rnl!lf R ECO MM EN DAT I O N s ffi=ffi=l.fETTEffi=cl Ii=" -m=m=~!T'-cl I Effi=I I 1cccffi=I I l"cl I i=ffi' =cm=m=m=m=f]F' -m-sffi='TTEm=TTEITEITF -TTl=fTT"'ITT="' °=lllccflEfficcffiEJW ·11,..,,_!..!lm!.!.h,-•1•· SECT[ON FLAGSTONE PAVING PREPARED BACKFILL PLANTING MEDIUM BETWEEN STONES -REFER TO PLANTING PLANS AND NOTES. NOTE: • SPACING OF CAST STONE PAVERS APPROXIMATELY 4" APART. • LANDSCAPE ARCHITECT TO APPROVE FINAL LAYOUT. N.T.S. WITH PLANTING OR LAWN BETWEEN 1>-~.i.o s c11¾' f:--~ "o 0, -; ,t \~ 0 ~':\ .)/ . -a -~. ~ , ;, ,~ "'11-\.~ (f ..__, __ .. QI?> '-....._Or: c;..\.\\" ....... _~ SECTION ~----------------SEE GRADING PLAN FOR FINISHED GRADE ~----------PLANTING AND LAWN EDGE ~------12" ALUMINUM STAKES TO LOCK INTO PREFORMED SLOTS ON THE EDGING NOTE: INSTALL PER THE MANUFACTURER'S RECOMMENDATIONS PERMALOC PH: 800--356-9660 (c) PERMALOC ALUMINUM EDGING N.T.S. APPROVED FOR /RR/GA TIO/\/ AND PLAI\I T/1\/G 01\!L Y, INC"L U0/1\/G PF?[C/5[ LOCA TIO/\! OF PLAJ\/ T/1\/G AREA. 11 AS BUILT 11 RCE EXP. DATE f./EVJEl,/ED BY, INSPECT □r, DATE J'l_lG.U :: B /1\ l<E '/1:il ON SHU -Cl'l'Y 01" CJ'd'{LSBAlJ ~)-I[ ! ' /"'\ l<E 1/l'il!JN .. '-! 1 . I ~. 1 -~ ~: u /J\ f<C VISION 5 PLA~l~!ING DIVISl □~I )O U1 .J 1.1 ·' :: !3 LAN USC Al' E: IMP IW V ,:11 J::NT PLANS F'Oll: BUENA VISTA 11 LAt",JDSCAPE CONSTRUCTION DETAILS _"-\PPPOVEC: /-1-J.., ~ ~~...;-!t -i,. c., .f-j, PLANNl~G OWN u V: ~· r-i f-'IW.Jf :: . i\D. Lf'>'.-\'•NIN::; I\J. L! \ ; \ -l\l OA fE INJT/Al DA/"E INI r; ~\L CHKLJ [JV REl/!SIOI\ DESCRi?TION CT 13-01 479-6L u:_,:::~-\:::~ :·:-r'iOR:.<.. OT•IER APPROVAL CI TY APPROVAL l<VWO E'1: IRRIGATION EQUIPMENT LEGEND SYMBOL MFR. MODEL DESCRIPTION WATER METER -LOCATIONS TO BE DETERMINED 0 IRRITROL SYSTEMS RME SENTAR-11-30 30 STATION CONTROLLER -WALL MOUNT W/PERMANENT MOUNTED PMRKIT AND JACK-IRC RECEIVER AND 1 XMRT 'PROMAX' REMOTE. LOCATION TO BE VERIFIED IN THE FIELD BY THE LANDSCAPE ARCHITECT. HOA VALVES 0 EACH LOT Jst -■- TORO RAINMASTER HUNTER FEBCO FEBCO SUPERIOR IRRITROL SYSTEMS RAIN BIRO NIBCO PVC PVC PVC RAIN BIRD NETAFIM TECHLINE CV EVOLUTION FS-150 MINI-CLIK 825Y 765-075 3100 700-1 -OMR-100 PEB T-580 T-113 SCH 40 SCH 40 SCH 40 SCH 80 5RC TLCV26-18 12 STATION CONTROLLER -WALL MOUNT WIPERMANENT MOUNTED PMRKIT AND JACK-IRC RECEIVER AND 1 XMRT 'PROMAX' REMOTE. LOCATION TO BE VERIFIED IN THE FIELD BY THE LANDSCAPE ARCHITECT. 1-112" FLOW SENSOR-RUN A MINIMUM OF 15" OF 1" PVC SCH 40 BEFORE AND 10" 1" PVC AFTER THE FLOW SENSOR. AUTOMATIC RAIN SHUTOFF DEVICE REDUCED PRESSURE BACKFLOW UNIT. -INSTALL A BRASS WYE STRAINER ON THE INLET SIDE OF THE UNIT-SEE IRRIGATION DETAILS PRESSURE VACUUM BREAKER TO BE INSTALLED A MINIMUM OF 6" ABOVE HIGHEST SPRINKLER -SEE IRRIGATION DETAILS 1" NORMALLY CLOSED MASTER CONTROL VALVE AT P.0.C. -BRONZE CONTAMINATION RESISTANT VALVE ELECTRIC REMOTE CONTROL DRIP VALVE WI OMNIREG & IRRITROL SYSTEMS 420-75 200 MESH WYE FILTER & IN-LINE 30 PSI PRESSURE REGULATOR -ADJUST FLOW CONTROL AND ADJUST OMNIREG TO 20 PSI ABOVE SYSTEM REQUIREMENTS. SIZE ACCORDING TO PLAN ELECTRIC REMOTE CONTROL VALVE -SIZES AS SHOWN ON PLAN, FOR VALVES WITH FLOW BELOW 3.0 GPM INSTALL RBY-100-200MX FILTER UPSTREAM OR VALVE. BRASS BALUGATE VALVE ON MAINLINE -LINE SIZE MAINLINE -FOR 1~" AND SMALLER USE SCH 40 PVC SOLVENT WELD, FOR 2" ANO LARGER USE CL 315 PVC. SIZE ACCORDING TO PLAN LATERAL LINE. SIZE ACCORDING TO THE PLAN PIPE & WIRE SLEEVING UNDER ALL PAVING, INSTALL AS SHOWN ON PLANS. USE SCH 40 LINES THAT ARE A MINIMUM TWO TIMES THE SIZE OF THE LINE IT SERVES, AND 2" MIN. FOR WIRE SLEEVE. 1" QUICK COUPLING VALVE PRESSURE COMPENSATING TECHLINE CV DRIPLINE WI CHECK VALVE, 0.26 GPH EMITTERS@ 18" O.C. SPACE LINES 18" O.C. IN PLANTING AREAS, 12" O.C. SPACE LINES 12" O.C. IN TURF. FOR HEDGES, MINIMUM 2 ROWS OF TUBING. SEE LANDSCAPE IRRIGATION DETAIL SHEETS FOR INSTALLATION GUIDELINES. 1. FOR ALL NETAFIM SYSTEMS USE A NETAFIM TECHFILTER (TFxx2618) FOR TECHLINE RUNS TOTALING 100' OR LESS USE[" (TF0752618). FOR RUNS TOTALING 100' TO 200' USE 1" (TF10912). FOR RUNS TOTALING 200' TO 500' USE 1" LONG (TF10L2618). FOR RUNS TOTALING 500' TO 1000' USE 1l" (TF15L2618). 2. INSTALL ALL IRRIGATION COMPONENTS TO CONFORM WITH ALL STATE AND LOCAL CODES AND PER THE MANUFACTURER'S RECOMMENDATION 3. PROVIDE ADEQUATE LIGHTNING PROTECTION FOR ALL ELECTRICAL COMPONENTS. 4. IT IS THE CONTRACTORS RESPONSIBILITY TO SET THE FLOW RATES FOR ALL STATIONS. THE MAINLINE MAXIMUM FLOW RATE IS TO BE INITIALLY SET AT 20% GREATER THAN THE FLOW RATE FOR THE HIGHEST FLOW VALVE. THIS SETTING IS PROVIDED AS A GUIDE ONLY. IT IS THE CONTRACTORS RESPONSIBILITY TO ADJUST SETTINGS AS NEEDED FOR VARYING SITE CONDITIONS. SEE MANUFACTURERS CATALOG FOR PCS SCREEN CHART -IF NEEDED SEE SHEET LID-1 FOR IRRIGATION GENERAL NOTES IRRIGATION POINT-OF-CONNECTION NOTES: 1 THE SPRINKLER SYSTEM DESIGN IS BASED ON A MINIMUM AVAILABLE FLOW OF 11 GPM AND A MINIMUM STATIC WATER PRESSURE OF 58 PSI AT THE POINT OF CONNECTION FOR THE SITE AND A MINIMUM AVAILABLE FLOW OF 8 GPM AND A MINIMUM STATIC WATER PRESSURE OF 42 PSI AT THE POINT OF CONNECTION FOR THE MODEL. THE IRRIGATION CONTRACTOR SHALL PROVIDE A PRESSURE REGULATOR AT THE POINT OF CONNECTION AS SPECIFIED ON PLAN. THE IRRIGATION CONTRACTOR SHALL VERIFY WATER PRESSURE ON SITE PRIOR TO CONSTRUCTION, REPORT ANY DIFFERENCE BETWEEN THE WATER PRESSURE INDICATED ON THE DRAWINGS, ANO THE ACTUAL PRESSURE READING TO THE LANDSCAPE ARCHITECT. 2 IRRIGATION CONTRACfOR IS RESPONSIBLE FOR COORDINATING CONNECTION TO THE P.O.C., WITH MINIMUM DISRUPTION TO THE EXISTING WATER SYSTEM. NOTIFY GENERAL CONTRACTOR 48 HOURS IN ADVANCE OF INSTALLATION, SCHEDULE INSTALLATION AT OWNER'S CONVENIENCE. 3. ALL PIPING BETWEEN POINT OF CONNECTION AND THE BACK FLOW PREVENTION DEVICE SHALL BE OF MATERIALS AND INSTALLATION METHODS REQUIRED BY LOCAL CODE. WHEREVER POSSIBLE, TRENCHING WITHIN THE DRIP LINES OF TREES SHOULD BE INSTALLED RADIAL TO THE TRUNK. IRRIGATION SYSTEM HEAD LAYOUT DUE TO THE SCALE OF THIS DRAWING THE CONTRACTOR SHOULD BE AWARE OF THE POSSIBILITY THAT THE NEED FOR MINOR ADJUSTMENTS TO THE IRRIGATION SYSTEM MAY BE NECESSARY TO PROVIDE 100% COVERAGE. THESE ADJUSTMENTS COULD INCLUDE NOZZLE CHANGES AND/OR ADDITION OR DELETION OF INDIVIDUAL HEADS TO COMPENSATE FOR CHANGES MADE ON THE SITE. PRESSURE COMPENSATING SCREEN (IF NEEDED) THE CONTRACTOR SHALL INSTALL ONE (1) TORO PRESSURE COMPENSATING SCREEN PER HEAD IN ALL IRRIGATION INSTALLATIONS WHERE RADIUS REDUCTION IS REQUIRED. USE OF THE SCREENS WILL ALSO AID IN MINIMIZING OVERSPRAY CONDITIONS AND FOGGING CAUSED BY EXCESS PRESSURE. FOR SCREEN SELECTION REFER TO PRESSURE COMPENSATING SCREEN CHART. PROVIDE A MINIMUM OF 2 EXTRA CONTROL WIRES OF A DIFFERENT COLOR AND 1 EXTRA COMMON TO THE END OF EACH MAINLINE RUN FROM THE CONTROLLERS. LOOP THESE WIRES INTO 1 VALVE BOX OF EACH CLUSTER ALONG THE RUN. PLACE LOCATOR TAPE ON ALL MAINLINE PIPE, EXCEPT WHERE VALVE WIRES ARE BUNDLED WITH THE MAINLINE. I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMIT.TING CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER." DETAIL NB B/8 N8,N9 B/8 NB,N9 C/9 NB, 018, N9 C/8 NB, DIS FIB NS E/8 NB B/9 NB, 018, N9 B/11 NB, 0/8, N9 B/10 NB, D/8, N9 0/9 NB,N9 E/9 NS E/9 NS F/9 N8 N10 NB,N9 C-F/11, A-C/12 NS IRRIGATION HEAD LEGEND PRECIP RATE/SYMBOL/GPM SST ADJ TO T F H Q 1.0 1.0 1.0 1.0 i!l 0 @ [~ .09 .26 .13 .04 1.0 1.0 1.0 1.0 i!l 0 0-Ei)- .22 .66 .33 .17 1.0 1.0 1.0 1.0 1.0 CJ m □ a-:t VAR. .34 1.03 .51 .23 1.0 1.0 ·1.0 1.0 1.0 1.0 1.0 [. 1' ,!ll [) • ~ -EO- VAR. 1.15 .99 .49 1.48 .74 .37 MFR TORO TORO TORO TORO MODEL DESCRIPTION 570Z-4P-PRX-COM-05 PRESSURE REGULATING 4" TURF POP-UP SPRINKLER W/ CHECK-0-MATIC CHECK VALVE AND TORO PRECISION NOZZLE 570Z-4P-PRX-COM-08 PRESSURE REGULATING 4" TURF POP-UP SPRINKLER WI CHECK-0-MATIC CHECK VALVE AND TORO PRECISION NOZZLE 570Z-4P-PRX-COM-10 PRESSURE REGULATING 4" TURF POP-UP SPRINKLER W/ CHECK-0-MATIC CHECK VALVE AND TORO PRECISION NOZZLE 570Z-4P-PRX-COM-12 PRESSURE REGULATING 4" TURF POP-UP SPRINKLER W/ CHECK-0-MATIC CHECK VALVE AND TORO PRECISION NOZZLE PSI RAD 30 5' 30 8' 30 10' 30 12' .55 .56 .56 .57 TORO 570S-12P-PRX-COM-R GEAR-DRIVEN 12" SHRUB POP-UP FULL 20 14'-26' ~ £ -£--4,- .78 2.56 1.22 .62 1.0 1.0 1.0 1.0 TORO ~< 0 -0--¢- .09 .26 .13 .04 1.0 1.0 1.0 1.0 TORO (_~ @ -0--$- .22 .66 .33 .17 1.0 1.0 1.0 1.0 1.0 TORO (0 CT) O e--E~- VAR. _34 1.03 .51 .23 1.0 1.0 1.0 1.0 1.0 1.0 1.0 TORO Ct -~ <;.t C.~ e -~--~ VAR. 1.15 .99 .49 1.48 .74 .37 CIRCLE OR PART CIRCLE ROTOR WI A BUILT-IN CHECK VALVE AND TORO PRECISION ROTATING NOZZLE 570S-12P-PRX-COM-05 PRESSURE REGULATING 12" SHRUB POP-UP SPRINKLER WI CHECK-0-MATIC CHECK VALVE AND TORO PRECISION NOZZLE 570S-12P-PRX-COM-08 PRESSURE REGULATING 12" SHRUB POP-UP SPRINKLER WI CHECK-0-MATIC CHECK VALVE AND TORO PRECISION NOZZLE 570S-12P-PRX-COM-10 PRESSURE REGULATING 12" SHRUB POP-UP SPRINKLER WI CHECK-0-MATIC CHECK VALVE AND TORO PRECISION NOZZLE 570S-12P-PRX-COM-12 PRESSURE REGULATING 12" SHRUB POP-UP SPRINKLER W/ CHECK-0-MATIC CHECK VALVE AND TORO PRECISION NOZZLE 30 5' 30 8' 30 1 O' 30 12' • SPRAY HEADS AGAINST WALLS, FENCES, AND MORE THAN 10' FROM WALKING SURFACES SUCH AS TURF, PATIOS, WALKS AND DRIVEWAYS, EXCEPT IN PROMINENTLY VISUAL AREAS OR WITHIN THE RIGHT-OF-WAY, MAY BE PA-BS SHRUB ADAPTERS ON FIXED RISERS WITH TRIPLE SWING JOINTS. ALL HEADS WITHIN THE RIGHT-OF-WAY SHALL BE POP-UPS. PROTECTION OF EXISTING OR NEW SPECIMEN TREES: 1 THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXISTING SPECIMEN TREES THAT ARE TO REMAIN IN THE PROJECT AND NEW SPECIMEN TREES THAT HAVE BEEN INSTALLED. ALL NECESSARY PRECAUTIONS SHALL BE TAKEN TO ASSURE THAT THEY ARE PROTECTED FROM DAMAGE BY WORKERS AND EQUIPMENT. 2. PROTECTIVE FENCING SHALL BE INSTALLED AT THE DIRECTION OF A CERTIFIED CONSULTING ARBORIST OR HORTICULTURALIST. 3. WHERE IT IS NECESSARY TO EXCAVATE IN CLOSE PROXIMITY TO EXISTING OR NEW SPECIMEN TREES, ALL POSSIBLE CAUTION SHALL BE EXERCISED TO AVOID INJURY TO ROOTS, LIMBS AND TRUNKS. EXCAVATION CLOSE TO TREES SHALL BE BY HAND. TUNNELING UNDER ROOTS TWO (2) INCHES AND LARGER SHALL BE ALLOWED ONLY AFTER DISCUSSION WITH AND APPROVAL BY A CERTIFIED CONSULTING ARBORIST OR HORTICULTURALIST. 4. EXCAVATIONS IN THE VICINITY OF TREES SHALL BE CLOSED WITHIN 24 HOURS. WHERE THIS IS NOT POSSIBLE, THE SIDE OF THE EXCAVATION ADJACENT TO THE TREE SHALL BE KEPT COVERED WITH MOIST BURLAP OR CANVAS. 5. THE CONTRACTOR SHALL INSURE THAT NO FOREIGN MATERIAL AND/OR LIQUID, SUCH AS PAINT, CONCRETE, CEMENT, OIL, TURPENTINE, ACID OR THE LIKE, BE ALLOWED TO CONTAMINATE ANY SOIL WITHIN THE DRIPLINE (I.E., THE OUTSIDE EDGE OF FOLIAGE OVERHANG) OF ANY TREE. IF SUCH CONTAMINATION SHOULD OCCUR, THE CONTRACTOR SHALL REMOVE SOIL AS DIRECTED BY A CERTIFIED CONSULTING ARBO RIST OR HORTICULTURALIST AND REPLACE IT WITH ACCEPTABLE SOIL AT NO EXPENSE TO THE OWNER. 6. ALL DAMAGE TO EXISTING SPECIMEN TREES SHALL BE REPAIRED AT THE GENERAL CONTRACTOR'S EXPENSE BY A LICENSED TREE SURGEON OR OTHER APPROVED PERSONNEL AS APPROVED BY A CERTIFIED CONSULTING ARBO RIST OR HORTICULTURALIST. 7. ANY EXISTING IRRIGATION SYSTEM AT ALL EXISTING OR NEW SPECIMEN TREES SHALL BE MAINTAINED IN WORKING ORDER FOR THE DURATION OF CONSTRUCTION. ANY DAMAGE TO THE EXISTING IRRIGATION SYSTEM SHALL BE REPAIRED IMMEDIATELY AT NO EXPENSE TO THE OWNER. RAIN SENSOR PLACEMENT: THE RAIN SENSOR SHALL BE INSTALLED ON THE SOUTH OR SOUTHWESTERN FACING AREA OF THE ROOF (WHENEVER POSSIBLE). THE AREA SELECTED SHALL BE IN A CLEAR OPEN AREA OF THE ROOF NOT AFFECTED BY SHADE FROM ANOTHER BUILDING OR TREE. THE CONTRACTOR SHALL INSTALL THE SENSOR ON AN EAVE OR FASCIA BOARD PER THE DIRECTION OF THE LANDSCAPE ARCHITECT. ALL WIRING SHALL BE CONCEALED PER THE DIRECTION OF THE LANDSCAPE ARCHITECT EITHER WITHIN PVC CONDUIT OR OTHER MEANS AS DIRECTED BY THE LANDSCAPE ARCHITECT. IN ACCORDANCE WITH THE CITY OF CARLSBAD LANDSCAPE DESIGN GUIDELINES, WATER EFFICIENT LANDSCAPING SIGNAGE TO BE INSTALLED AT THE MODEL ALONG WITH AN INFORMATIONAL BROCHURE TO HIGHLIGHT WATER EFFICIENCY PRINCIPLES UTILIZED WITHIN THE LANDSCAPE. DETAIL C/10 C/10 C/10 C/10 N11 0110 0/10 0110 D/10 PRESSURE LOSS CALCULATIONS •HOA AREAS· VALVE 8 IRRIGATION SECTION QUANTITY PSI LOSS FACTOR TOTAL PSI LOSS 3/4" SCHEDULE 40 PVC 0.88 ·----------------- 1" SCHEDULE 40 PVC 0.08 -----· ----------------------·----· ----------••-------------· --- 5.14 3.36 0.3 3.36 0.03 4.5232 0.2688 0.3 11.1888 0.06 11 0.8 2.399 1" VALVE@1038(3Plvl f . ·-.. 1 1" SCHEDULE 40 PVC , __ 3.33 ---.----·---------··- 1" BRASS BALL GATE VALVE , 2 -·---------·-··--------------------------------- 1" BACKFLOW PREVEt-HOR ______ 1 _ 1 1" WATER METER i 1 --·--------·--•· ·---·---·---·----,----• ---.. -· 10% LOSS FOR FITTINGS 1 ELEVATION CHANGE FROM POC -4 TOTAL PSI LOSS , PSI NEEDED AT FINAL HEAD ,-------. - TOI~_l:'SI NEEDED FOR ?YSTEM ---... -·· AVAILABLE PSI AT POC • RESIDUAL PSI % ' MODEL HOME -VALVE 1-6 I IRRIGATION SECTION I QUANTITY 3/4" SCHEDULE 40 PVC i 0.62 3/4" VALVE@ 6.57 GPM ________ ,! _____ 1 ________ .. _ 3/4" SCHEDULE 40 PVC 1.54 ·---------··--·---------:, 3/4" BRASS BALL GATE VALVE I 1 -----··· 3/4" BACKFLOW PREVENTOR 5/8" WATER METER . . ----· . ··- 10% LOSS FOR FITTINGS ELEVATION CHANGE-FROM POC -[ RESIDUAL PSI % i ·LOT 9 -VALVE 9-3 IRRIGATION SECTION I 3/4" SCHEDULE 40 PVC : I 1 1 1 0 QUANTITY 0.8 1 3/4" VALVE@ 3.47 GPM r ----------·------------+-------------- 3/4" SCHEDULE 40 PVC ! 0.85 -·-----r--- 3_!i"_BBASS ElALL GATE V~VE ___ [_ ---.. 1 __ ··--· _ 3/4" BACKFLOW PREVENTOR I 1 5/8" WATER METER 10% LOSS FOR FITTINGS 1 1 -------------·------------·----------1 ----------·· .. ELEVATION CHANGE FROM POC • 0 TOTAL PSI LOSS -------.. ----------··--·· ---·- PSI NEEDED AT FINAL HEAD ' --------------------.... -i· TOTAL PSI NEEDED FOR SYSTEM ' AVAILABLE PSI AT POC ! RESIDUAL PSI % - LOTS 2-8 & 10-11 -NETAFIM VALVES IRRIGATION SECTION QUANTITY -- TOT AL PSI NEEDED FOR SYSTEM --------------------- AVAILABLE PSI AT POC RESIDUAL PSI % 11 0.8 2.399 0.433 PSI LOSS FACTOR 1 5.14 1 0.5 5.14 -1.732 28.8078 20 48.8078 58 16% TOTAL PSI LOSS 3.1868 0.5 7.9156 0.05 4 1.8 1.663 0 19.1154 I ~---4~ 11~ I 58 I 15% PSI LOSS FACTOR I TOTAL PSI LOSS 5.14 0.5 5.14 0.05 ----- 4 1.8 1.663 0.433 4.112 0.5 4.369 0.05 4 1.8 1.663 --- 0 16.494 30 46.494 58 20% PSI LOSS FACTOR' TOTAL PSI LOSS 5.14 ------------ 0.1 5.14 3.855 0.1 0.6682 10.9962 -- 30 40.9962 58 29% APPRO \/[0 FOR /RR/GA TIO!\/ ANO PLAAITING OA/L Y, IAICLUOIAIG PR[CIS[ LOCATION OF PLAJ\/TING AREA. 11 AS BUILT 11 f-cCE __ _ EXP. ___ _ DATE f-cEl/!Ev/ED BY, fNSPECTOR DATE 01.13.14 CB k\ REVISION CITY OF' CARL BAD ~~=.,____--l------1-----~---l 7 SHEETS 20 12.10.13 CB /t\ REVISION LE] 1 1 s 01.21.14 CB /.J\ REVISION PLANNING DIVISION ;:::l=,A=N::::D::::S::::C::'..A.'.:P::::E=:lM=P::::f::::lO=V::::E::::,, M=E::::•'N::::'::::I' =P::::L=A=N:::'S:::' =F::::'O::::R=: ===:'....'.::====: BUENA VISTA 11 LANDSCAPE IRRIGATION NOTES t--t-----+-------------1----+---+-----+----~I IA -P-PR_ov_E_D:~rez_:;;J_-~!1-_q::+--~lc:l=I.Jt=' ~- _PLANNING DATE INITIAL DESIGNER OF WORK DATE INITIAL FsE\/ISION DESCRIPTIO~I DATE INlflAL OTHER APPROVAL CITY APPfWVAL OWN BY: CR CI-IKD BY: __ _ RVWD BY: PROJECT NO. CT 13-01 DRAWING NO. 479-6L G) IRRIGATION GENERAL NOTES: r~iE SPRINKLEF{ SYS rEM DESIGN IS BASED ON A MINIMUM AVAILABLE FLOW OF 1·1 GPM AND A MINIMUM STATIC WATER PRESSURE OF 58 PSI AT THE POINT OF CONNECTION FOR THE S!TE /\ND A MINIMUM /\V/\ILABLE FLOW OF 8 GPM ANDA MINIMUM STATIC WArER PRESSURE OF 42 PSI AT THE POINT OF CONNECTION FOR THE MODEL. THE IRRIGATION CONTRACTOR SHALL PROVIDE A PRESSUF'\E REGULATOR AT THE POINT OF CONNECTION AS SPECIFIED ON PLAN. THE IRRIGATION CONTRACTOR SHALL VERIFY WATER PRESSURE ON SITE PRIOR TO CONSTRUCTION, REPORT ANY DJFFERENCE BETWEEN THE WATER PRESSURE lNOlCATED ON THE DRAWINGS, AND THE ACTUAL PRESSURE READING TO THE LANDSCAPE ARCHITECT 2. IRRIGATION CONTRACTOR IS RESPONSIBLE FOR COORDINATING CONNECTION TO THE P.O.C., WlT!-1 MINIMUM DISRUPTION ro THE EXISTING WATER SYSTEM. NOTIFY GENERAL CONTRACTOR 48 J--lOUF'\S IN ADVANCE OF INSTALLATION, SCHEDULE INSTALLATION AT OWNER'S CONVENIENCE. 3. ALL PIPING BETWEEN PO!NT OF CONNECTION AND THE BACK FLOW PREVENTION DEVICE SHALL BE OF MATERIALS AND INSTALLATION METHODS REQUIRED BY LOCAL CODE. 4. THIS DESIGN IS DIAGRAMMATIC, ALL PIPING, VALVES, ETC. SHOWN WITHIN PAVED AREAS ARE FOR DESIGN CLARIFICATION ONLY, AND SHALL BE INSTALLED JN PLANTING Afl:EAS WHERE POSSIBLE. AVOID t\NY CONFLICTS EJETWEEN rHE ff{RIGATION SYSTEM AND EXISTING s mucruRES, u nuTIES AND PLANTING. 5. IRRIGATION SLEEVING UNDER PAVING fO BE PROVIDED BY IRRIGATION CONTRACTOR. VERIFY SLEEVING REQUIREMENTS IN FIELD AND REPORT ANY DISCREPANCIES TO LANDSCAPE ARCHITECT. SLEEVES SHALL BE PROVIDED BY IRRIGATION CONTRACTOR AND SHALL BE SCHEDULE 80 PVC AND SIZED PER THE SPECIFIGATJONS AND THE LEGEND. EXTEND All SLEEVES MINIMUM TWELVE (12) INCHES BEYOND PAVING EDGES. 6. EXERCISE EXTHEME CARE WHEN EXCAVATING FOR IRRIGATION SYSTEM DUE TO EXISTING U flLITIES. IT JS THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO BECOME FAMILIAR WITH All GRADE DIFFERENCES, LOCATION OF WALLS, STRUCTURES AND UNDERGROUND UT!UTIES 7. rHE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PLANT MATERIALS SCHEDULED TO F~EMAIN ON SITE. HE SHALL TAKE ALL NECESSARY PRECAUTIONS REQUIRED TO ASSURE THAT THEY ARE PROTECTED FROM DAMAGE FROM WORKERS AND EQUIPMENT. 8. WHERE IT JS NECESSARY TO EXCAVATE IN CLOSE PROXIMITY TO EXISTING PLANT M1\TERIAL, ALL POSSIBLE CAUTION SHALL BE EXERCISED TO AVOID INJURY TO ROOTS AND TRUNK. TUNNELING UNDER ROOTS TWO (2) INCHES OR LARGER SHALL BE ALLOWED ONLY AFTER REVIEW BY THE LANDSCAPE ARCHITECT. THE PRUNING AND TRJMMING OF BRANCHES AND ROOTS OF PLANT MATERIALS WILL BE DONE BY EXPERIENCED WORKERS WITH THE CONSENT OF THE ARBORIST. 9. WHEN IT IS OBVIOUS IN THE FIELD THAT OBSTRUCTIONS, GRADE DIFFERENCES, OR DISCREPANCIES IN THE AREA DIMENSIONS EXIST, SUCH DIFFERENCES SHOULD BE BROUGH r ro THE AHENTION OF THE OWNER'S ON SITE REPRESENTATIVE FOR RESOLUTION. IF SUCH NOTJFICATION IS NOT GIVEN, THE IRRIGATION CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY NECESSARY F./.EPAIRS AND/OR REVISIONS. 10. lRRIGArlON CONTRACTOR SHALL BE RESPONSIBLE FOR PULLING ADDITIONAL VALVE WIRING AS INDICATED ON PLAN 11. JNSTALL ALL MATERIALS AND EQUIPMEN r AS SHOWN IN THE DETAILS. USE TEFLON TAPE ON ALL MALE PIPE THREADS, ON All SPRINKLER SWING JOJNT ASSEMBLIES, AND VALVE ASSEMBLIES. 12 ALL HEADS LOCATED ADJACENT TO WALKS, RAMPS, F'IOADWAY PAVEMENT, CURBS AND/OR PARKING AREAS SHALL BE INSTALLED WITH TRIPLE SWING JOINTS 13. ALL VALVES AND QUICK COUPLERS SHALL BE LOCATED IN SHRUB PLANTING AREAS WHEREVEH POSSIBLE. LOCATE 36" FROM TURF, HARDSCAPE, PATHS, CURBS, AND WALLS. REMOTE CONTROL VALVES SHALL BE INSTALLED BELOW GRADE IN VALVE BOXES AS SHOWN ON DETAILS. 14. 120 VOLT ELECTRICAL POWER OUTLET SHALL BE PROVIDED BY THE OWNER. THE IRRIGATION CONTRACTOR SHALL MAKE THE FINAL HOOKUP FROM THE ELECTRICAL OUTLET TO THE AU fOMATIC CONTROLLER. 15, FLUSH AND ADJUST ALL SPRINKLER HEADS FOR OPTIMUM PERFORMANCE, AND TO PREVEN r OVER SPRAY ONTO WALKS, ROADWAYS, AND/OR BUILDINGS. THIS SHALL INCLUDE SELECTING THE BES r DEGREE OF ARC TO FIT THE EXISTING SITE CONDITIONS, AND TO THRO rfLE THE FLOW CONTROL SYSTEM AT EACH VALVE TO OBTAIN OPTIMUM OPERATING PRESSURE FOR EACH SYSTEM PER MANUFACTURER'S RECOMMENDATIONS. 16 INSTALL ANTI-DRAIN CHECK VALVES ON ALL SPRINKLER HEADS AS REQUIRED TO PREVENT RESIDUAL FLOW. 17. IRRIGATION CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING CONCRETE THRUST BLOCKS WHERE NECESSARY ON THE MAINLINE AND/OR LATERAL LINES TO PROTECT THE LINE FROM WATER SURGING. 18 OWNER IS RESPONSIBLE FOR SCHEDULING THE IHRIGATION SYSTEM TO MEET HORTICULTURAL REQUIREMENTS AND TO INSURE THAT EXCESSIVE SOIL SATURATION AND/OR SOIL EROSION DOES NOT OCCUR. 19. PRECIPITATION RATES {PPT) AND GPM SHOWING IN THE IRRIGATION HEAD LEGEND ARE GIVl::N UNLY AS A GENERAL INDICATION OF NOZZLE PERFORMANCE. ACTUAL PRECIPITATION RATES/GPM'SARE DEPENDENT UPON THE 1\PPLICATION TIME OF EACH SYSTEM. fHE APPLICATION TIME FOR EACH SYSTEM SHALL BE ADJUSTED TO PROVIDE A UNIFORM WATER COVERAGE. IN NO El/ENT SHALL THE DURATION OF SPHINKLING BE PERMITTED SUCH AS TO CREATE A SATURATED CONDITION AND CAUSE AN EROSION PROBLEM. 20. IRRIGATION CONTRACTOR SHALL FOLLOW ALL MANUFACTURER'S INSTr'\UCTIONS AND RECOMMENDATIONS FOR INSTALLATION ANO COORDlNAflot~ OF THE IRRIGATION SYSTEM, INCLUDING HEADS, POROUS PIPE, MASTER VALVES, CONTROLLERS AND STATION VALVES TO INSUHE A COMPLETE SYSTEM. 21. FINAL AS-BUILT PLANS SHALL BE SUBMIHED TO THE CITY TO BE REVIEWED, APPROVED, AND SIGNED PRIOR TO RELEASE OF SECURITIES. ALL HEADS IN RIGHT-OF-WAY SHALL BE POP-UPS. HEADS MORE THAN 10' FROM WALKING SURFACES SUCH AS TURF, PATIOS, WALKS AND DRIVEWAYS -EXCEPT IN PROMINENTLY VISUAL AREAS, OR IN THE RIGHT-OF-WAY -MAY BE PA-8S SHRUB ADAPTERS ON FIXED RISERS WITH TRIPLE SWING JOINTS. ---------------------------PRESSURE SUPPLY LINE FROM WATER METER -SCHEDULE K HARD COPPER -------------------BRASS 'Y' STRAINER (#40 MONEL SECTION/ELEVATION MESH) WITH 3/4" HOSE BIB -------------REDUCED PRESSURE BACKFLOW PREVENTER WITH GATE VALVES -----MINIMUM 24" X 24" X 24" GRAVEL SUMP UNDER ALL DISCHARGE POINTS ~ BRASS UNION OR FLANGES -TYPICAL / (2) PLACES ---MINIMUM 1 CUBIC FOOT CONCRETE THRUST BLOCK SCHEDULE 40 PVC MALE ADAPTER ~ ;--SCHEDULE 40 PVC PRESSURE • •j / MAINLINE =iii:e !!/ii~ ' ; -~ er,, ;;:· NOTES: ·INSTALL 12" FROM WALLS OR BUILDINGS, INSTALL WITH TEST COCKS FACING OUTSIDE. ·ALL FITTING AND NIPPLES TO BE THREADED BRASS. ·CONFORM TO ALL LOCAL AND STATE CODES. CD BACKFLOW PREVENTER REDUCED PRESSURE N.T.S. I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER." ---!:!----------AUTOMATIC CONTROLLER (REFER TO PLANS FOR LOCATION) ----+ii-----------COLOR CODED MAP FOR VALVE -LOCATION, INSIDE DOOR •---•11-----------PROVIDE ON/OFF SWITCH & 110 VOLT I -EXTERIOR OUTLET INSIDE CABINET " ------------3" PVC SWEEP ELL (BY GENERAL CONTRACTOR) ~---------120 VOLT CONDUIT TO SOURCE ------FINISHED GRADE OR PAVING SURFACE WHERE IT OCCURS ili~~frnilli ._____;r---..!:/ 24 VOLT CONTROL WIRES, ( 1) COMMON WIRE TO ALL RCV'S, (1) CONTROL WIRE TO EACH RCV, TAPE@ 10' INTERVALS NOTES: · PROVIDE GROUNDING ROD AS REQUIRED BY CODE ·CONTROL WIRING TO BE AWG. UF#14 UNLESS OTHERWISE NOTED SECTION/ ELEVATION ·COMMON WIRE TO BE WHITE & CONTROL WIRE TO BE RED IN COLOR ·NO SPLICES SHALL BE MADE BETWEEN CONTROLLER & REMOTE CONTROL VALVE UNDER 500 LINEAR FEET N.T.S. AUTOMATIC CONTROLLER WALL MOUNTED 99999-00liw --------------------LOW VOLTAGE WIRES, 3 MAXIMUM ELEVATlON ----------------OUTER CASE OF CONNECTOR ~--CONNECTOR INSERT ~----CRIMP COPPER SLEEVE INSTALLED WI RECOMMENDED TOOL ~----STRIP AND TWIST WIRES FOR PROPER CONNECTION NOTE: FILL OUTER CASE WI SEALER PRIOR TO FINAL ASSEMBLY. ® WIRE CONNECTION N.T.S. -------------SURFACE ~-~~------MOUNTING BRACKET ¾\--------------MOUNTING SCREW (1 OF 2) -----------WIRE TO IRRIGATION CONTROLLER SECTION/ ELEVATION RAIN SENSOR ------WIRE TO REMOTE CONTROL VALVE L+ NOTE: MOUNT IN AN AREA THAT WILL BE EXPOSED TO UNOBSTRUCTED RAINFALL, BUT NOT IN THE PATH OF SPRINKLER SPRAY. N.T.S. WIRED NORMALLY CLOSED 'J9'.l<J'J-0021e ----------------------PRESSURE SUPPLY LINE FROM WATER METER -SCHEDULE K HARD COPPER -----------------PRESSURE VACUUM BREAKER -PLACE w ~.A= w . -r 1 E • , ~ SECTION/ ELEVATION A MINIMUM OF 6" ABOVE HIGHEST SPRINKLER ---------BRASS UNION OR FLANGES -TYPICAL (2) PLACES NOTES: ·INSTALL 12" FROM WALLS OR BUILDINGS, INSTALL WITH TEST COCKS FACING OUTSIDE. ·ALL FITTING AND NIPPLES TO BE THREADED BRASS. ·CONFORM TO ALL LOCAL AND STATE CODES. PRESSURE VACUUM BREAKER N.T.S. APPRO\/[O FOR /RR/GA TIO/\/ A/\/0 PLA/\ITI/\IG ONLY, INCLUOI/\/G PR[CIS[ LOCA TIO/\/ OF PLANTING AR[A. 11 AS RC[ ___ EXP. ___ _ DATE REVIE\./ED BY, INSPECT □r, DATE 1:'.10.1..: (:[3 If RF:VISION ~ C'l'.l'Y. Q_L,' C'f.\_D_L,S'.U_"\.U ~, Ul.151-: ::u ;~\hl\/1'310N l l\ Ur ~~=.,____--1.-1-------1---------l-----l ~ ,JI.; I . I : ;· l3 /:\ f<I •ii :310N ===='--'====P:::::::L::::A::::N::::N::::!N::::G::::::D:::l::::V:::::::::I s::::· I::::0:::N:::::====:....:===~ LANl!C::l';Wl: l.llf'IW\ll:\IE:NT PLANS f'Ofl: BUENA VISTA 11 LANDSCAPE !RRIGATIDI\I DETAILS ,1PPf<Cl'/EC: PLAflNl~G DATE F<Ev:s Oi\ DESC RiPTION li'JI rlAL DATE 1/\11 fl AL OTHER APPROI/Al CITY APPROVAL OWN l3 V: :~H CHKD LJY: __ _ RVWD B V: PIW.Jf_c: t--0. CT 13-01 479-6L ua: O!l'. !l'.O f-Z IDENTIFICATION GUIDE ~~ WW wz zo ";--JW w~ w<( -< Jc, ~~ "J: :'ii! Ow ~z 0 0 "'J "" ~ 0 w z a-a: 0 w 33 0 D ow RW A ARV AIR RELIEF VALVE ow RW A BS BASKET STRAINERS ow RW A COMM COMMUNICATION SPLICES ow RW A Fl FERTILIZER INJECTORS ow RW A FS FLOW SENSORS ow RW A FVA FLUSH VALVE ASSEMBLY ow RW A GR GROUNDING RODS ow RW A GV GATE VALVES ow RW A MS MOISTURE SENSORS ow RW A MV MASTER VALVE ow RW A SB SPLICE BOX ow RW A (STA#) REMOTE CONTROL VALVES ow RW A QC QUICK COUPLERS CONTACT LANDSCAPE ARCHITECT FOR INFO ON ANY DEVICE IN A BOX NOT LISTED. SAMPLE: POTABLE WATER SYSTEM OF CONTROLLER "A" REMOTE CONTROL VALVE ON STA. #9 PLAN NOTES: A-VALVE BOXES SHALL BE LABELED BY HOT IRON BRANDING OR ALUMINUM ASPHALTIC BASE WATERPROOF PAINT. B-CONTROL VALVES SHALL BE INSTALLED TO ALLOW ORDERLY ARRANGEMENT OF VALVE BOXES. C-LOCATE VALVE ASSEMBLIES IN SHRUB OR GROUNOCOVER AREAS ONLY. 0-LOCATION OF VALVE ASSEMBLIES SHALL BE STAKED FOR APPROVAL BY LANDSCAPE ARCHITECT PRIOR TO INSTALLArlON. E-CENTER VALVE BOXES OVER VALVE ASSEMBLE ro FACILI fATE ACCESS AND MAINTENANCE. F-SET VALVE BOXES AT EQUAL ELEVATIONS W/TOPSAT 2" ABOVE FINISH GRADE IN SHRUB/ GROUNDCOVER AREAS. G-VKVE BOXES SHALL BE SET PARALLEL TO EACH OTHER AND PERPENDICULAR TO EDGE OF AREA. H-DO NOT DEFORM OH COLLAPSE VALVE BOX BY EXCESSIVE SOIL COMPATION AROUND BOX. 1-SEE ALSO INDIVIDUAL VALVE !NSTALLATfON DETAILS. TYPICAL VAL VE BOX IDENTIFICATION N.T.S. ---------10" ROUND PLASTIC VALVE BOX WITH COVER MARKED "IRRIGATION GATE". REFER TO PLANS AND SPECIFICATIONS FOR APPROVED MANUFACTURERS ~ 2" IN SHRUB/GROUNDCOVER AREAS -y fflilllilwf!E~ lb,-----------,,!J ~Jrmfrrl~m[jj=8 'l'=ffi=ffi=flE=1ITI-Trt= 0f1Ef1Ef1Effi=ITT=~ 'TJ=ifi=ffi=Tr-1=r '=ITE.1 ocTTl'ccfTI=ili=iT' "-0m=11 F-11 m ITTc;;lfl';';ffi;;c;i I I=-~ .,IJITT_~~ ----ll',~ 1 u,,"",m"'E'c""'m:;;u;::, '------LINE SIZE BALL VALVE, REFER TO IIF-lft=I 'flETTE'' PLANS & SPECIFICATIONS, NIBCO "'=i!Fmf ~~ BRASS MODEL #T-580 8cd',p==;:::;:="-__)'l-------SCHEDULE 40 PVC MALE ADAPTER (2 REQUIRED) SECTlON/ELEVATJON BALL VALVE (ISOLATION VAL VE) I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER." NOTE: ALL VALVE BOXES TO BE INSTALLED IN GROUND COVER AREAS REFER TO PLAN FOR LOCATIONS. N.T.S. ----------------FINISH GRADE ------WATERPROOF CONNECTION (1 OF 2)- 'SNAP-TITE' OR APPROVED EQUAL ~-----ID TAG -'T. CHRISTY' (800) 258-4583 -------GREEN RECTANGULAR VALVE BOX W/BOLT-DOWN COVER, 12" SIZE, W/'RCV' & STATION NUMBER ON COVER. SEE -,----·-,,~, -="1 ='=. __ ,..... ______ -+-~--_,,-1-w PLANS & SPECS FOR MANUFACTURER. ·=w=1 I I -IT=ffi= z ::, m-111= z =111=11, riif ~,-i ' i/-W,=\s:=w~----30" LINEAR LENGTH OF WIRE, COILED , _ -1/. • ~ BRASS UNION AND NIPPLES (TYP.) NOTE: MASTER VALVE TO BE INSTALLED IN GROUNDCOVER AREAS ONLY. SECTlON /ELEVATION --11-------PVC SCH 40 45' ELL (4 TYP.) 11------ELECTRIC REMOTE CONTROL VALVE - REFER TO IRRIGATION LEGEND ----PVC SCH 40 PRESSURE MAINLINE MASTER REMOTE CONTROL VAL VE N.T.S. 9')')')')-0071~ ~--------------MINIMUM COVER: AS REQUIRED t SECTlON LINE TRENCHING 18" FOR LINES 3" IN DIAMETER OR LESS 24" FOR LINES 3" -5-1/2" IN DIAMETER 36" FOR LINES 6" OR GREATER IN DIAMETER -----SCHEDULE 40 PVC NON-PRESSURE LATERAL LINE ~----FINISHED GRADE ---TYPE 'UF' DIRECT BURIAL CONTROL & COMMON WIRES, BUNDLE & TAPE WIRES TOGETHER EVERY 10 FEET ----SCHEDULE 40 PVC PRESSURE MAINLINE --COMPACTED OR UNDISTURBED SUBGRADE NOTES: • EXCAVATE TRENCHES TO REQUIRED DEPTHS. • TRENCH BO rfOM SHALL BE FLAT TO INSURE PIPING IS SUPPORTED CONTINUOUSLY ON AN EVEN GRADE. ALL ADJUSTMENTS TO GRADE SHALL BE MADE BY SCRAPING AWAY OR FILLING IN WITH CLEAN EARTH BACKFILL MATERIAL, WELL COMPACTED UNDER Tl-IE BODY OF THE PIPE. PIPE SHALL BE SNAKED IN TRENCHES. ·ALL LINES SHALL HAVE A CLEARANCE OF 6" FROM UTILITY LINES OF OTHER TRADES. DO NOT INSTALL PARALLEL LINES DIRECTLY OVER ONE ANOTHER. -W~IERE PIPE SLEEVING OCCURS UNDER PAVING, EXTEND THE ENDS OF SLEEVING 12" BEYOND PAVING. -PROVIDE 20" EXPANSION LOOP IN WIRING AT ALL CHANGES OF DIRECTION GREATER THAN 30 DEGREES, UNTIE LOOPS AFTER ALL CONNECTIONS HAVE BEEN MADE. • BACKFILLING SHALL BE DONE IN 6" LIFTS UNTIL FINISHED GRADE IS REACHED. FIRST LAYER SHALL BE FREE FROM SHARP ROCKS OR CLODS OF DIRT OVER 112" IN SIZE. N.T.S. ')'J'J')')-0101~ NOTE: ALL VALVE BOXES TO BE INSTALLED IN GROUND COVER AREAS. REFER TO PLAN FOR LOCATIONS. -----------10' ROUND PLASTIC VALVE BOX WITH COVER MARKED "FLOW SENSOR" REFER TO PLANS AND SPECIFICATIONS FOR APPROVED MANUFACTURERS -----------WATERPROOF CONNECTION (1 OF 2) - 'SNAPTITE' OR APPROVED EQUAL f'. ~--------2" IN SHRUB/GROUNOCOVER AREAS rim1' ~11 -m='m='m=m= -1=-L',------,''---;a!J 1rn;g1 i;;m;:;;m;:;;ITT'aTfFr --1 iTEm-rr3w=l""ffi =====-=~-----ID TAG-'T. CHRISTY' (800) 258-4583 '=ffi-~m=ffi"em-m=r 'ITEflEm"em"errl"c'rJI '=~111=m=m=m=m =IT"EI 11=m=m=11, ,~~.m ~m=TTF~ TE~mecrn~~ ~urm~mmmwmri ~--111c;[IJ;;;"ITT=c;II!ccm-'-.!I_I"'~ ________ FLOW SENSOR CABLE BY ARIZONA ELECTRICAL -=~~Wi~~nr "l.!J]T[UI:-FABRICATORS #9516-2SP OR APPROVED EQUAL (C) z :e --=iu~w~ ",;, ---~ 1"PVCCONDUIT _____ ,._ __________ FLOW SENSOR ,r--\----------SCHEDULE 40 PVC MALE ADAPTER (2 REQUIRED) ~--------------------ALLOW MIN. DISTANCE OF 5 PIPE DIAMETERS FROM NEAREST DOWNSTREAM VALVE, FITTING, METER, OR REDUCING COUPLER SECTION/ELEVATION PLASTIC FLOW SENSOR N.T.S. AS REQUIRED SECTlON SLEEVING ,.,-----MINIMUM COVER: UNDER ROADS (SCH 80): 6" OR LESS -36", >6" -48", UNDER PAVING (SCH 40): <3" -18", 3" • 5-1/2" -24", 6" OR GREATER -36" ~---4-------HARDSCAPE SURFACE -SEE PLANS. ,,-----CLEAN BACKFILL AS REQUIRED, REFER TO ENGINEER FOR SPECIFIC MATERIAL AND COMPACTION REQUIREMENTS. ~---CLEAN SAND. .,.------SCHEDULE 40 OR 80 PER MINIMUM COVER NOTE ABOVE PVC LATERAL LINE WITH SLEEVE. .,.------TYPE 'UF' DIRECT BURIAL CONTROL & COMMON WIRES, SLEEVE SIZE AS REQ. __,-----SCHEDULE 40 OR 80 PER MINIMUM COVER NOTE ABOVE PVC PRESSURE MAINLINE WITH SLEEVE NOTES· •EXCAVAfE TRENCHES TO REQUIRED DEPTHS. ·TRENCH BOTTOM SHALL BE FLAT TO INSURE PIPING IS SUPPORTED CONTINUOUSLY ON AN EVEN GRADE. ALL ADJUSTMENTS TO GRADE SHALL BE MADE BY SCRAPING AWAY OR FILLING IN WITH CLEAN EARTH BACKFILL MATERIAL, WELL CIJMPACTED UNDER THE BODY OF THE PIPE. PlPE SHALL BE SNAKED IN TRENCHES. ·ALL LINES SHALL HAVE A CLEARANCE OF 6" FROM UTILITY LINES OF OTHER TRADES. 00 NOT INSTALL PARALLEL LINES DIRECTLY OVER ONE ANOTHER. • EXTEND THE ENOS OF SLEEVING 12" BEYOND PAVING. • SEE LEGEND AND/OR SPECIFICATIONS FOR SLEEVE SIZING. • BACKFILLING SHALL BE DONE IN 6~ LIFrS UNTIL FINISHED GRADE IS REACHED. N.T.S. 'J?'J'.l9-0llle APPRO \/ED r OFt /RR/GA TION ANO PLAAI TIAIG OA/L Y, INCLUDING PRECISE LOCA T!ON or PLANTING AREA. REVl'ilON f<l 1/ISION fiEVISi01, DESCRIPTION DATE INI HAL OTHER APPROVAL DATE INITIAL CITY APPROVAL RCE EXP, DATE REVJE\,/ED BY, INSPECTOR DATE ~ CITY OF' C Af<LSB1\D SHl-L PLANNING DJVJSI □N /0 ' LANDSCc\l'E: IM I' IW \I 1::.11 f: N 'J' I' Li\NS F'OR BUENA VISTA 11 LANDSCAPE IRRIGATION DETAILS APPROVED: ~ lc:,lt--0it -i . <.. . r..J' PLAflNING OWN BY: r F, Pf!OJE C T NO. [)f< .\ WING ~J. CHKD BY: HI/WD BY: CT 13-01 479-6L 18" MIN. f -------QUICK-COUPLING VALVE -SEE PLAN FOR LOCATION, SEE IRRIGATION LEGEND FOR MANUFACTURER ------EDGE OF PAVING b,;;,,.,6n,~;j~' ~--,c -1------VAL VE BOX WITH COVER: 6" SIZE ·; 1"' -1TEITT'=ITT' · =rr· -ITI~m=m=l n!IF.-nl@'...;]!cS"1=lf11J~i;;;:;;0=:::f------PVC SCH 80 NIPPLE (LENGTH AS ~m!]F / 'lllm-· REQUIRED) =JTF""/ ,~ 3" MIN. DEPTH OF 3/4" WASHED GRAVEL ----------PVC SCH 40 STREET ELL ---------BRICK (1 OF 2) -------PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) ~~~::__-_-_ ---.L_~=-_,-=--=--=-=-=-----PVC SCH 40 STREET ELL A-----PVC SCH 40 TEE OR ELL 1-------"s~¾--l. ___ ..J-~ '-----------PVC SCH 40 MAINLINE PIPE '----------PVC SCH 40 ELL NOTES: '-------------2" X 2" REDWOOD STAKE W/STAINLESS STEEL GEAR CLAMPS OR EQUIVALENT ·FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TO NOMINAL QUICK-COUPLING VALVE INLET SIZE. ·USE TEFLON TAPE ON ALL THREADED CONNECTIONS SECTION/ ELEV ATJON SUPPORT SYSTEM 0 QUICK-COUPLING VAL VE ------------------------EDGE OF PAVING 4" MIN. ---------SPRAY OR STREAM POP-UP SHRUB HEAD --------FINISHED GRADE: N.T.S. 'J<J999-012ie \r--'-----,1 f 2" BELOW PAVING IN GROUND COVER ------PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) -------PVC SCH 40 ELL -------HOPE (MARLEX) SCH 40 STREET ELL -----PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) ----HOPE (MARLEX) SCH 40 STREET ELL '------PVC SCH 40 TEE OR ELL '-------PVC SCH 40 LATERAL PIPE SECTlON/ELEVATION NOTE: (HDPE) HIGH DENSITY POLYETHYLENE POP-UP SHRUB HEAD W /TRIPLE SWING JOINT AT BOTTOM INLET I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER." N.T.S. NOTE: ALL VALVES TO BE INSTALLED IN GROUND COVER AREAS ONLY. SECTION/ ELEVATION --------30" LINEAR LENGTH OF WIRE, COILED --------WATERPROOF CONNECTION (1 OF 2)- 'SNAP-TITE' OR APPROVED EQUAL --------ID TAG -'T. CHRISTY' (800) 258-4583 --------GREEN RECTANGULAR VALVE BOX W/BOLT-DOWN COVER, 12" SIZE, W/'RCV' & STATION NUMBER ON COVER. SEE PLANS & SPECS FOR MANUFACTURER. -------PVC SCH 40 MALE ADAPTER '--------3" MIN. DEPTH OF 3/4" WASHED GRAVEL '---------PVC SCH 40 NON-PRESSURE LATERAL LINE (~) REMOTE CONTROL VAL VE N.T.S. '.l'J'l<J9-0!Jle --~ttDSCAP&•...._ ~--~~~" " C) o/,-'" .,_ () "' -,:, ~ ~,,. T S ~¥~ )I~ ·" ""'r ,,..~ $' ----0~ '-::.,or-<;A\..f'i-.... _~- ----------------------EDGE OF PAVING 2"MIN. ---------SPRAY POP-UP LAWN HEAD --------FINISHED GRADE: 1" BELOW PAVING IN TURF ------PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) -------PVC SCH 40 ELL -------HDPE(MARLEX)SCH40STREETELL -----PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) ----HDPE (MARLEX) SCH 40 STREET ELL ~ PVC SCH 40 TEE OR ELL -------PVC SCH 40 LATERAL PIPE SECTION/ ELEV A TION NOTE: (HOPE) HIGH DENSITY POLYETHYLENE POP-UP LAWN HEAD N.T.S. W /TRIPLE SWING JOINT AT BOTTOM INLET 99')')')-003,h 0 APPROVED FOR /RR/GA T!ON ANO PLAAI TIA/G OA/L Y, INCLUOIA!G PR[CIS[ LOCATION OF PLAA/ TING AREA. ''AS BUILT" RCE EXP. DATE REVIE\./ED BY, INSPECTOR DATE 1). IC.13 :: E3 Ii\ r,r 1/I'.JON I •;~~[ I CITY OF' CAELSBAD ')HU. ,· IZ\ I,I-vIsI0~I ' u1.1.,1: :: t3 PLANNl~IG D!VlS!□N /(j LANIJSC!ll-'E: L\ll-'IWVL\11::NT PLANS \"OIi: BUENA VISTA 11 LA/\IDSCAPE IRRIGATID/\1 DETAILS ,IPPFU vEC: /ill Gr-8L..,ft t> &-1--l PLf\NNlf\G OWN O '1 : :'' I I f-'f.:CJ JI :: -f\J. L,f~·\W!N~; f\J. L) .\ . \ \I r_i L\ TE INlrlAI_ D~\ IT 11'11 Ti,\:_ C HK[J [j "': REvs,or-; DC:SC '~l'''TION CT 13-01 479-6L l.i~-'.'., '.;\~;~ .::;::-,'/1);':.:,s 0 IHER APPFWVAL CIT)' APPROI/Ac.. R1/W[J B ·,, --',---------------SHRUB ROTOR HEAD 0 ----------CHECK VALVE (AS REQUIRED) --------#3 REBAR (MIN. 24" LONG) -------STAINLESS STEEL STRAP FASTENERS (MIN. 2 REQUIRED) -----PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) -----FINISH GRADE ---PVC SCH 40 ELL --PVC SCH 40 TEE OR ELL r--PVC SCH 40 LATERAL PIPE NOTE: USE TEFLON TAPE ON ALL THREADED CONNECTIONS SECTION SHRUB OR STREAM ROTOR HEAD ON RISER W /CHECK VALVE -----------FINISH GRADE N.T.S. ')9999-007,h ----------------BACKFILLED TRENCH (FREE OF DEBRIS) SECTION/ ELEVATION (D) LANDSCAPE DRIPLINE TRENCHING I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGUcATIONS AND THE LANDSCAPE MANUAL AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER." N.T.S. NOTE ALL VALVES TO BE INSTALLED IN GROUND COVER AREAS ONLY. SECTION/ELEVATION ,----------·--30" LINEAR LENGTH OF WIRE, COILED ----------ID TAG -'T. CHRISTY' (800) 258-4583 ----------WATERPROOF CONNECTION (1 OF 2) - 'SNAP-TITE' OR APPROVED EQUAL ----FINISH GRADE '-------------IN-LINE WYE FILTER '------------IN-LINE PRESSURE REGULATOR '--------------PVC SCH 40 PRESSURE MAINLINE 0 PRESSURE REG. DRIP VALVE N.T.S. W /WYE FILTER AND IN-LINE PR.ESSURE R.EGULATOR. SECTION/ ELEVATION ~ LANDSCAPE DRIPLINE \_J ON-GRADE INSTALLATION ')')')')<J-00\ii,<.J --.y~~ '<t'v "Yo !~=¾ ...d 1" 0 ~-~ ·~\ . ,;,~ ....... "")'~ ~~ 0 ,O ,.~~~ 1/ 1C. L~ :; 8 'J1.L~.1-'. :: lJ U-\ .. \ .. 1\l DC'i,•~\::_:::.; ·.:=-·NOR',< --------------FINISH GRADE --------------PVC TEE (SXSXS) COMPRESSION FITTING FOR DRIPLINE LANDSCAPE DRIPLINE -GPH, EMITTER SPACING, AND DISTANCE BETWEEN LINES PER PLANS -+---------SCHEDULE 40 PVC CONNECTION --------PVC SCH 40 ELL (SxS) ---=---PVC SCH 40 LATERAL PIPE SECTION/ELEVATION DRIPLINE SUPPLY HEADER BELOW-GRADE INSTALLATION -------FINISH GRADE ------BRICK (1 OF 2) SECTION/ELEVATION TECHLINE CV LINE FLUSHING VAL VE PLUMBED TO PVC N.T.S. 999'J9-002ii,tl N.T.S. APPROVED !RR/GA TIO/\/ Ai\/0 FOR PLA/\I Tf f\!G 0/\/L Y, INCLUOI/\/G PRECISE LOCA TIO/\/ OF PLA/\! TING AREA. 11 AS BUIL T 11 RCE EXP. DATE REV!Ev/ED BY: INSPECT□r, DATE /1\ f![VISION IT] CITY OF' Ci-\HLSBi-\D :JHH ''; /,!\ r,rv1·;10,1 PLANNING D!V[S!DN )(J I LANIJSC,Wl: IMP~OV~ll~NT PLANS f'OR BUENA VISTA 11 LANDSCAPE ]1'(1-! I GA T ION DETAILS I APPf,01/ED: 11J( 4' -<Id I _.-if -i-c..-1+ Pl ANNING OWN BY: r• R PfiOJfC, NO. 1;1nw1w; l\'.J. D/\TE INI rlAL 0f\TE INITIAL CHKD BY: RE\/IS:ON DESCR,PTION CT 13-01 479-6L OTHER APPF~OI/AL CITY APPf"W\/AI RI/WD BY: I S;c-_ LINE FLUSHING VALVE PLUMBED TO PVC PIPE (TYP.) ~ ' W1 I I I PVC SCH 40 EXHAUST HEADER W/ 12" I COVER OVER PIPE -SEE DETAIL I I I TECH LINE LATERAL TUBING I ~ PVC SCH 40 SUPPLY HEADER W/ 12" COVER OVER PIPE -SEE DETAIL / I J / TECHLINE START CONNECTION (PVC TO ELL) -SEE DETAIL I / I/ :o-, / I ELECTRIC REMOTE CONTROL VALVE W/ DISC FILTER AND PRV -REFER TO IRRIGATION EQUIPMENT LEGEND I I AREA PERIMETER ~ I I I -l -~ PERIMETER LATERALS 2" TO 4" FROM I I EDGE li LATERAL BANK TECHLINE TUBING ~ -TECHLINE START CONNECTION F (PVC TO ELL) -SEE DETAIL PLAN G) TECHLINE CV "CENTER FEED" LAYOUT I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER." N.T.S. I I I I I I I I I I I I I /;, "' I '-,(e}----------LINE FLUSHING VALVE PLUMBED TO PVC PIPE (TYP.) ['---------AREA PERIMETER r-#'llh---------TECHLINE LATERAL TUBING I I V -------TECHLINE START CONNECTION (PVC TO ELL) -SEE DETAIL I !----------PVC SCH 40 EXHAUST HEADER W/ 12" COVER OVER PIPE -SEE DETAIL G;/1 K o: J~--------TECHLINE TEE 0 '~ ' "' '-' ' ' '- !'LAN ,~! c---------LATERAL BLANK TECHLINE TUBING IH---------PVC SCH 40 SUPPLY HEADER W/ 12" ' ' ' ,, I COVER OVER PIPE -SEE DETAIL ',I ~-----------ELECTRIC REMOTE CONTROL VALVE W/ DISC FILTER AND PRV -REFER TO IRRIGATION EQUIPMENT LEGEND TECHLINE CV IRREGULAR AREAS TR.IANGULAR LAYOUT N.T.S. 9\l<J<J'.I-0U5111<.l . --- -~~-~()~).) ~'?_F CS C '::,/? --- /4 F )-,----------------LINE FLUSHING VALVE PLUMBED TO PVC PIPE _4! '~---------------AREA PERIMETER d ~~-\\\\--\\-\·t-1--------------PVC SCH 40 EXHAUST HEADER W/ 12" g , COVER OVER PIPE -SEE DETAIL '-I '-\\ \ '-_\ ✓\\~-,-\~I--'-\-,--------------TECHLINE TEE I I / '-'I' -----------LATERAL BLANK TECHLINE TUBING TUBING ''-~ ~ '---------......_____ . PLAN ' " /2 -"-c-----TECHLINE LATERAL TUBING ~---TECHLINE STARf CONNECTION (PVC TO Ell) -SEE DETAIL /.,.;"'----PVC SCH 40 SUPPLY HEADEF\ W/ 12'' COVER OVER PIPE -SEE DETAIL -----ELECrnIc REMOTE CONTROL VALVE W/ D!SC FILTER AND PRV -REFER TO IRRIGATION EQUIPMENT LEGEND NOTES; -ORIP-LINES TO BE EQUALLY & UNIFORMILY SPACED FOR ENTIRE LENGTH OF RUN. SPACE LINES AS SHOWN AND/OR NOTED ON DRAWINGS ~ SPECS. -SEE:. NETAFIM. 'TEC!-ILINE DESIGN GUIDE' FOR ADDITIONAL INFORMATION. .ORIP-UNES TO BELAYED FLAT AND SECURED TO SUBGRADE W/ STAPLES AT 5' CENTERS PRIOR TO BACK-FILL OR MULCH COVER .USE CAUTION VVl-!EN SECURING DRIP-LINE WI STAPLES. DRIP-LJNE SHALL NOT BE OBSTRUCTED OR KINKED. TECHLINE CV IRREGULAR AREAS ODD CURVES LAYOUT N.T.S. 'J')'J'l'J-006tuLi ------------VALVE BOX WITH COVER: 6" SIZE APPROV[O FOR !RR/GA TIO!\/ ANO PLA/1/ Tl/1/G 01\/L Y, lf\!CLUOING PR[C!S[ LOCATION OF PLAI\I TING AR[A RCE __ _ EXP. ___ _ DATE REV IE'dED BY, INSPECTOR DATE u1.1.,.1-· ::o A 1;c:v1s1oe1 1:-1. 1:-1. I) IC.1.l ::u /(\ r,[VISION m c·.[rI'Y o·F-, C "Rl,SB 1\D ';HI! -, ~"--+~"-"-'-'-----e----+---+-----1-----1 . ;·,, Cl.)1.1: c:lJ /1 fiFVl<;iOel ~==:'....'::====P::::L=A=N:::::1'-l::::IN=G:::::D:::l:::::\/:::::l::::S::::l□:::l'-=I===::::::....===-:=::; LANDSCM'i:; lMP!WVl::MI::N'J' PLANci 1'00H: BUENA VISTA 11 LANDSCAPE IRRIGATION DETAILS : PLMINING I APPROVED: ~I ~ \;:_ll-6tt_ 't-G ·If° I REVSIOr\ DESC R"-'TION D'111'-I BY: CR PliOJEC -t\O. l.;f'(.\'J\/11\(; I\J. DA1E /t\JI f/1\L DATE INITiAL CHKD Ei Y: OTHER APPROVAL CITY APPROVAL RVWO El Y: CT 13-01 479-6L ,----WOOD GATE ACCESS FOR HOA MAINTENANCE CREW-SEE DETAIL PROPERTY LINE (TYP.) TREE SYMBOLS EXISTING STREET TREE TO BE REMOVED THROUGH CITY MUNICIPAL CODE GUIDELINES FOR STREET TREE REMOVAL. PARKS DEPARTMENT TO REVIEW AND APPROVE APPLICATION PRIOR TO REMOVAL OF STREET TREES 0 PROPOSED TREE NOTE WELL: NO EXCAVATION OF ANY KIND IS TO OCCUR ANYWHERE ON SITE WITHOUT FIRST VERIFYING THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES. I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER." LOT 4 20 ' ~ LOT 5 r ,,. LOT 8 [ I I I I I I I ~ ,J - LOT 9 / • / w " • -'"AG / T • ~-WOODGATE (TYP.), SEE DETAIL ( SUBDIVISION BOUNDARY ------WATER PIPELINE EASEMENT EXISTING ROAD RIGHT-OF-WAY EASEMENT PROPOSED ROAD RIGHT-OF-WAY -------EASEMENT ~-VEHICULAR SIGHT TRIANGLE (TYP.) ""::. -------1 -B-C G 0 -- LOT 7 OVERFLOW DRAIN PIPES FROM BIORETENTION BASINS -SEE CIVIL PLANS ~ PLANTED BIORETENTION BASINS (TYP.) -SEE CIVIL PLANS '-----RETAINING WALL (TYP.) -SEE CIVIL PLANS 20 50 ii f-----' N ~ SCALE: 1 "~20' \ "' ~ \ ··,\ ""'· ,\ \ \~~\\ \\, \\ \ \\ \ \\ \ \\\ " \\ ~~- --RETAINING WALL (TYP.) ,~ WOOD FENCE (TYP.) -SEE DETAIL ~:___ _______________ WATER SERVICE (TYP.) !'V----------------------SEWER SERVICE (TYP.) TREE LEGEND Symbol Botanical Name Common Name AM Arbutus 'Marina' Strawberry Tree DC Dwarf Citrus Species -TBD TBD EUC CIT Eucalyptus citriodara Lemon Gum LOP CHO Lophostemon confertL1s Brisbane 8ox MAG GRA Magnolia grandiflora Southern Magnolia MAG GRA 48 Magnolia grandiflora Southern Magnolia MN Melaleuca nesophila Pink Melaleuca Swan Hill Olive Rootball Size Quantity 15 Gal 3 24'' Box 2 15 Gal 10 15 Gal 15 24" Box 8 48" Box 5 15 Gal 48 24" Box 4 OE Olea europaea 'Swan Hill' -----------~--------------~---~--- --DRAINAGE (TYP.) -SEE CIVIL PLAN '-----SDG&EEASEMENT APPRO VEO FOR /RR/GA TIO/\/ Af\/0 PLA/\IT/f\/G 0/\/L Y, INC"LUOING PRECISE LOCA TIO/\I OF PLANTING AREA. --PROPOSED HOA MAINTENANCE EASEMENT -~--PROPOSED 30' PUBLIC UTILITY EASEMENT RCE __ _ f,EVIE\✓ED BY, INSPECT OF/ EXP, ----DATE DATE SHEETS 20 12.10.13 cB 1 REVISION ~ c' l'.l'Y o·.L,' C'A!YLs·.13-_tu L,0._,_1.._,_1"'3.-'-14+~c...,·B--t-'-ic-·-~f:",E~l/~IS=IO~~'--I -----------j----j----j-----t-----i . L \ -i '. PLANNING DIV ISI□~l 01.21.14 CB REVISION ~==='-'==============:'..':====: LANDSCAPE IMPIWVE:.IJCNT PLIINS FO[i: BUENA VISTA 11 TREE PLANTING PLAN 1----1---+----------------j----j----j-----t-----i I APPROVED: .PLANNING 1---~--1~~-+----------------+----+--+-c-c::c-t-c:-::-cc-1 ~D::;~==,N:::;::BY==,==c:::;B=:::;-;::==P==R=O=JE=c=T=N=O=.=~==o=R=A=W=IN=G=N=O=:. oE~;:~R 0t,:;~K REVISION DESCRIPTION 0~::: APP:~:;:~ ~~TT: APP::;:~ ~~~g ~~: ---CT 13-Q 1 4 79-6L I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER." PLANTING NOTES: 1. ALL WORK PERFORMED SHALL CONFORM TO THE STANDARDS AND SPECIFICATIONS OF LOCAL AND/OR STATE JURISDICTIONS. CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS, INSPECTIONS AND APPROVALS REQUIRED FOR THIS WORK. 2. THE CONTRACTOR MUST VERIFY THE LOCATIONS OF UNDERGROUND UTILITY LINES IN FIELD PRIOR TO ANY EXCAVATION, AND IS RESPONSIBLE FOR THE COST OF REPAIRING ANY DAMAGE. REQUEST APPROVAL FROM LANDSCAPE ARCHITECT FOR ANY DEVIATION IN PLANT MATERIAL LOCATIONS. 3. FINAL GRADES SHALL BE WITHIN TWO (2) INCHES BELOW CURB AND/OR PAVING GRADE IN SHRUB AREAS, AND ONE (1) INCH BELOW CURB AND/OR PAVING GRADE IN LAWN AREAS. 4. ALL TREES AND SHRUBS ARE TO BE REVIEWED AND APPROVED BY THE OWNER OR LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. 5 ALL TREE DELIVERIES MUST BE COORDINATED WITH THE GENERAL CONTRACTOR. 6. ALL TREE LOCATIONS ARE TO BE REVIEWED AND APPROVED BY THE LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. 7. ALL PLANTING PLANS ARE DIAGRAMMATIC, AND THE CONTRACTOR SHALL TAKE EVERY PRECAUTION TO ENSURE THAT THE ROOTBALLS OF NEW AND EXISTING TREES ARE NOT DISTURBED. 8 ALL ON-CENTER SPACINGS FOR SHRUBS AND GROUND COVERS ARE TRIANGULAR SPACINGS. 9. ALL GROUND COVER SHALL EXTEND BENEATH ALL PLANT MATERIAL. 10. ALL VINES AND ESPALIERS ARE TO BE REMOVED FROM STAKES OR TRELLISES AND ATTACHED TO WALLS WITH APPROVED DEVICES (SEE DETAIL). 11. A MINIMUM OF 3" ORGANIC MULCH SHALL BE ADDED TO NON-TURF PLANTING AREAS WITH SLOPES LESS THAN 31 TO COVER THE SOIL SURFACE COMPLETELY. 12. THE CONTRACTOR SHALL CONTACT THE LANDSCAPE ARCHITECT PRIOR TO BEGINNING LANDSCAPE WORK SO THAT LANDSCAPE ARCHITECT CAN REVIEW THE PROJECT UTILITY LOCATIONS AND REVISE PLANS ACCORDINGLY TO FULLY SCREEN ALL UTILITIES FROM VIEW MODEL SOIL PREPARATION & BACKFILL MIX SPECIFICATIONS: THE FOLLOWING SPECIFICATIONS ARE TO BE USED FOR COST ALLOWANCES ONLY FINAL SOIL PREPARATION AND BACKFILL MIX RECOMMENDATIONS TO BE BASED ON RESULTS OF REQUIRED SOIL TESTS. MODEL SOIL PREPARATION: (PER 1000 SQUARE FEET) ALLOW FOR A MINIMUM OF 4 CUBIC YARDS/1000 SQUARE FEET NITROGEN-STABILIZED ORGANIC AMENDMENT (AS SPECIFIED IN SECTION 02821, PAR. 2.01) ALLOW FOR A MINIMUM OF 150#/1000 SQUARE FEET 'GRO-POWER' 5-3-1 ALLOW FOR A MINIMUM OF 20#/1000 SQUARE FEET SOIL SULFUR BROADCAST UNIFORMLY AND ROTOTILL INTO UPPER FOUR (4) TO SIX (6) INCHES OF SOIL. MODEL BACKFILL MIX FOR TREES AND SHRUBS: (PER CUBIC YARD) 3 PARTS BY VOLUME NITROGEN STABILIZED ORGANIC AMENDMENT 7 PARTS BY VOLUME SITE SOIL 20# 'GRO-POWER 5-3-1' PER CUBIC YARD OF MIX MODEL BACKFILL MIX FOR RHODODENDRONS, AZALEAS AND/OR CAMELLIAS· (PER CUBIC YARD) 113 BY VOLUME -PRE-MOISTENED SPHAGNUM PEAT MOSS 1/3 BY VOLUME -APPROVED TOPSOIL 1/3 BY VOLUME -AMENDED SITE SOIL 10# -'GRO-POWER 3-12-12 FLOWER & BLOOM' FERTILIZER PER CUBIC YARD OF MIX 3# -'GRO-POWER PREMIUM GREEN IRON -40% Fe' PER CUBIC YARD OF MIX MODEL BACKFILL MIX FOR PERENNIALS AND ROSES: (PER CUBIC YARD) 1/3 BY VOLUME -PRE-MOISTENED SPHAGNUM PEAT MOSS 2/3 BY VOLUME -AMENDED SITE SOIL 10# -'GRO-POWER 3-12-12 FLOWER & BLOOM' FERTILIZER PER CUBIC YARD OF MIX PROTECTION OF NEW SPECIMEN TREES: 1. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NEW SPECIMEN TREES THAT HAVE BEEN INSTALLED. ALL NECESSARY PRECAUTIONS SHALL BE TAKEN TO ASSURE THAT THEY ARE PROTECTED FROM DAMAGE BY WORKERS AND EQUIPMENT. 2. PROTECTIVE FENCING SHALL BE INSTALLED AT THE DIRECTION OF A CERTIFIED CONSULTING ARBORIST OR HORTICUL TURALIST. 3. WHERE IT IS NECESSARY TO EXCAVATE IN CLOSE PROXIMITY TO NEW SPECIMEN TREES, ALL POSSIBLE CAUTION SHALL BE EXERCISED TO AVOID INJURY TO ROOTS, LIMBS AND TRUNKS. EXCAVATION CLOSE TO TREES SHALL BE BY HAND. TUNNELING UNDER ROOTS TWO (2) INCHES AND LARGER SHALL BE ALLOWED ONLY AFTER DISCUSSION WITH AND APPROVAL BY A CERTIFIED CONSULTING ARBORIST OR HORTICUL TURALIST. 4. EXCAVATIONS IN THE VICINITY OF TREES SHALL BE CLOSED WITHIN 24 HOURS. WHERE THIS IS NOT POSSIBLE, THE SIDE OF THE EXCAVATION ADJACENT TO THE TREE SHALL BE KEPT COVERED WITH MOIST BURLAP OR CANVAS. 5. THE CONTRACTOR SHALL INSURE THAT NO FOREIGN MATERIAL AND/OR LIQUID, SUCH AS PAINT, CONCRETE, CEMENT, OIL, TURPENTINE, ACID OR THE LIKE, BE ALLOWED TO CONTAMINATE ANY SOIL WITHIN THE DRIPLINE (I.E., THE OUTSIDE EDGE OF FOLIAGE OVERHANG) OF ANY TREE. IF SUCH CONTAMINATION SHOULD OCCUR, THE CONTRACTOR SHALL REMOVE SOIL AS DIRECTED BY A CERTIFIED CONSULTING ARBORIST OR HORTICULTURALIST AND REPLACE IT WITH ACCEPTABLE SOIL AT NO EXPENSE TO THE OWNER. 6. ALL DAMAGE TO SPECIMEN TREES SHALL BE REPAIRED AT THE GENERAL CONTRACTOR'S EXPENSE BY A LICENSED TREE SURGEON OR OTHER APPROVED PERSONNEL AS APPROVED BY A CERTIFIED CONSUL TING ARBO RIST OR HORTICUL TURALIST. 7. ANY IRRIGATION SYSTEM AT ALL EXISTING OR NEW SPECIMEN TREES SHALL BE MAINTAINED IN WORKING ORDER FOR THE DURATION OF CONSTRUCTION. ANY DAMAGE TO THE IRRIGATION SYSTEM SHALL BE REPAIRED IMMEDIATELY AT NO EXPENSE TO THE OWNER. SOIL TESTING REQUIREMENTS: SOIL TESTING FOR AGRICULTURAL SUITABILITY IS REQUIRED FOR ALL LANDSCAPE AREAS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING SOILS TESTING AND SOIL AMENDMENT RECOMMENDATIONS. SOILS TESTING SHALL BE COMPLETED AND TEST RESULTS AND AMENDMENT RECOMMENDATIONS SUBMITTED TO THE OWNER'S REPRESENTATIVE A MINIMUM OF FIFTEEN ( 15) DAYS BEFORE COMMENCEMENT OF ANY PLANTING. THE TESTING LABORATORY SHALL BE APPROVED BY THE OWNER'S REPRESENTATIVE. ( REFER TO SECTION 01630) THE TESTING LABORATORY FOR SOILS ANALYSIS SHALL USE THE FOLLOWING CRITERIA FOR SOIL TESTING; USDA AGRICULTURAL SUITABILITY TEST PER HANDBOOK 60, TO INCLUDE BORON PRESENCE AND CONTENT; AND UNIVERSITY OF CALIFORNIA SOIL FERTILITY TEST. INTERPRETATIONS, FERTILIZATION AND SOIL AMENDMENT RECOMMENDATIONS, ANO COMMENTS REGARDING THESE TESTS ARE REQUIRED. SOILS TEST SITES SHALL OCCUR NOT MORE THAN 250 FEET ON_ CENTER IN THE PLANTING AREAS, UNLESS OTHERWISE NOTED ON PLANS. SAMPLES OF ALL IMPORT SDIL FROM EACH SOURCE SHALL ALSO BE SUBMITTED TO THE SOILS TESTING LABORATORY FOR ANALYSIS, INTERPRETATION AND RECOMMENDATIONS PRIOR TO PLACEMENT, BLENDING OR BACKFILLING. TEST RESULTS SHALL BE SUBMITTED TO LANDSCAPE ARCHITECT BEFORE DELIVERY OF SOIL AMENDMENTS. APPLICATION RATE TABLE GRO-POWER 7 GRAM PLANTING TABLETS, 12-8-8 with 20%%% Humus and 4%%% Humic Acid Plant Size # of Tablets 1 Gal Plant 2 2 Gal Plant 3 5 Gal Plant 6 15 Gal Plant 12 20"-24" Box 15 Specimen Trees & Shrubs 4 Tablets for every inch of Caliper Note: Place tab!et(s) no higher than 1/3 of the way up the rootball spaced equally around the perimeter of the rootbal! approximately 2" from the root tips. --......._ , p,J.\.OSG/lp~ 12.10. 13 01.13.14 01.21.14 CB NOTE WELL: NO EXCAVATION OF ANY KIND IS TO OCCUR ANYWHERE ON SITE WITHOUT FIRST VERIFYING THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES. '1\ f,EI/ISION APPROVED FOR /RR/GA T/Ot\/ AA/0 PLAAITIAIG ONLY, /1\/C'LUOIA/G PRECISE LOCA T!Ot\/ OF PLAN TING AREA. RCE___ EXP, ___ _ DATE REV!Elt!ED BY, INSPECTOF/ DATE CB i>\ REVISION fsHm7 ClTY OF' C1\f{LSBA1J SHEETS 20 CB /1. REVISIO~I -""'---l-'-'ic"-'-'=-"="-'--------------+---+-----l-----l---l l____1_'l__j PLAM~II~IG DIVIS !ON ""-----l-LO!..>....'..'..=...!..'.="-'--------------l---+---11----+---1~===-'================-.'::-=====~ LANDSCAPE: l.\lf'IWVJ::.\ICNT Pl.AN::i F'OI<: BUENA VISTA 11 TREE PLANTING NOTES ~--"'"'\, ,, ':\,, t' ? CJ ~ .J ... ,,..~ I ~ \~ \;__ 2/iP-¥ . l-----f---+--------------------ll----+---l----+---11 APPROVED , -/ \ I /'t,,.d:'., J q B\-Q%~--z. ""'•1+- 1----+---l-----------------+---+---l---1---J '.::;P:=LA:::,N:::.N=:.lf::::I_G=-=-=-:::..:::..=-~::::-;:========~====~· ~ ,~ DATE INITIAL " ...__ __ Q~ RE\/ISIO~I DESCRIPTIO~! 0Fc;A\.\1 DESIGNER OF WORK ...... ____. .•. OWN BY: _CB__ PROJECT NO. DRAWING NO. ~~~,g ~~: --CT 13-01 4 79-6L DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPfWVAL r----WOOD GATE ACCESS FOR HOA MAINTENANCE CREW-SEE DETAIL A""-""""--==.,,.-./-/-WOOD GATE (TYP.), SEE DETAIL ------SUBDIVISION BOUNDARY FLAGSTONE PATH FOR HOA ACCESS GARJAS PHO PS AGANOV WES FRU LAM MAC WES FRU ROS APP PHO PS GAR JAS RHA BAL GAR JAS WES FRU ROS APP GAR JAS ROS APP AGANOV GARJAS HEU PP AGANOI/ PHO PS TRA JAS (TYP.} LAM MAC GARJAS WES FRU FIC REP (TYP.) ~ ____-:: LAUNOB~ MUH LIN LEY CON I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER." .. RJAS Si :L LEld CON MAU APP GAR JAS FRU AElAL HLIN u pp FES IDA{fYP.) COT DAM (TYP.) CEA YP 7 ,,,,-AEOZWA / PIIVAR BUENA VISTA WAY ALY HUE LAV STO CON MAU ,,-PHO rr OST FRU CAR BB CON MAU ------ PHO PS VIBTIN- SALLEU DOD VIS CON MAU AGANOV -----WATER PIPELINE EASEMENT ON MALr------- CEA YP PITVAR- AEO ZWA SAL LEU\ _\.---CON MAU EXISTING ROAD RIGHT-OF-WAY . -.. \ - • • AR JAS HEU PP GA NOV I LEY CON WES FRU ROS APP R' ROS APP .--MUH LIN GAr~ JAS GARJAS LAM MAC TRA JAS (TYP.) CARB PHO P CARS 1-!A. JAS o-PHO JS '-ff,--->AEO z{'j,;A AR BB LOT 1 AGANO -, PHO PS _ --------1\ ·. './'. -· CAR BB • .. \ ~s===-~ . ~ LOT 2 • ·+ + + ·\" + I-J--1-+ ·+ 1-_ + -1- + .• -1-I-. + + • 't-+ +-• ·f • LOT 3 LOT 4 +. + +· + + ·I-·I-+ + ·, r. +· r • + + • + • OST FRU AGANOV PHO PS OST FRU CAR BB PHO PS AGANOY CAR BB AGANOY CON MAU OST FRU PHO PS CAR BB AGANOV --CON MAU --CAF{BB CAR BB PHOTr PHO JS COT DAM COT DAM CEA YP PHO P AGANO GARB OST FR CON MA LOT 8 LOT 7 \.....---CON MAU OSTFRU GAF{ BB osrmu OST mu~ CON MAU OST FRU CAR BB AGANOV PHO PS CAF{ BB CON MAU OST FRU PHO PS AGANOY~ ~l2 CON MAU -~~ CON MAU-------:,----7 ~-=-~'\!:> CAR BB - 0. · .. ·.· LOT 9 ·!·-~· . J t._: .•. :_.~ : 1-:-:-r'.-.-.J:-~:-• .: . ' ... ::. . : . .. LOT 6 BOULDER GROUPING LOT 10 ~LOT 11 PHOJS, _________ _ hAV{W' EASEMENT VIB TIN PROPOSED ROAD RIGHT-OF-WAY L-.-----EASEMENT -i ~ VEHICULAR SIGHT TRIANGLE (TYP.) ~)- o)..A ~ CON MAU ~ AEOZWA ~~ AGA NOV /' RETAINING WALL (TYP.) WOOD FENCE (TYP.) -SEE DETAIL TREE SYMBOLS e PROPOSED TREE GROUNDCOVERSYMBOLS [] FESIDA G COT DAM ' NOTE WELL: NO EXCAVATION OF ANY KIND IS TO OCCUR ANYWHERE ON SITE WITHOUT FIRST VERIFYING THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES. LOT 5 APPROVED F"OR !RR/GA T!ON AND PLAN TING 01\/L Y, !A!CLUO!A!G PRECISE LOCATION or PLAAIT!NG AREA. 20 0 ' ~-PROPOSED HOA MAINTENANCE EASEMENT OVERFLOW DRAIN PIPES FROM ~---PROPOSED 30' PUBLIC UTILITY EASEMENT ~-BIORETENTION BASINS -SEE CIVIL PLANS ~ PLANTED BIORETENTION BASINS (TYP.) -SEE CIVIL PLANS RCE __ _ r,E\/JE,/ED BY, INSPECTOR EXP. ___ _ DATE DATE 12.10.13 CB r,Ev1s10N ~ CITY OF CAftLSBAD l'0'-'1-'-.1'-'3"-. '-14'-t-_C=.cB:---t-~r':::r,=E""\/l'::S~IO~~-'-I -------------ii----t---ii----t--, 5 ~-------------~ 01.21.14 CB REVISION _ PLA~INING D1\/JS!DN SHEETS 20 '---RETAINING WALL (TYP.) -SEE CIVIL PLANS 20 40 60 '-----i SCALE: 1 "~20' ----J,'1'i-OS0Apf: ~ ,,,◊ -<,;, ~0 C; !)' ., I ~,,, "'I;-----~"\; ,,. 0 , 0 '-...., F GA\..\€ .... __ . DATE INITIAL DESIGNER OF WORK REVISION DESCRIPTI0/\1 LANIJSC'APE IMPROVEMENT PLANS F'OR BUENA VISTA 11 SHRUB AND GR □UNDC □VER PLANTING PLAN APPROVED: IM) ~ E:-11~-tr ..Z,G,1--\ PLANNING DWN BY: _ca_ PfWJECT ~10. DRAWING NO. DATE INITIAL DATE INITIAL CHKD BY: CT 13-01 479-6L orHER APPROVAL CITY APPROVAL r,vwo BY: SHRUB LEGEND PLANTING NOTES: SOIL TESTING REQUIREMENTS: 1. ALL WORK PERFORMED SHALL CONFORM TO THE STANDARDS AND SPECIFICATIONS OF LOCAL SOIL TESTING FOR AGRICULTURAL SUITABILITY IS REQUIRED FOR ALL LANDSCAPE AREAS, Container/ AND/OR STATE JURISDICTIONS. CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS, Rootball On-Center INSPECTIONS AND APPROVALS REQUIRED FOR THIS WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING SOILS TESTING AND SOIL AMENDMENT Symbol Botanical Name Common Name Size Spacing Quantity RECOMMENDATIONS. SOILS TESTING SHALL BE COMPLETED AND TEST RESULTS AND AMENDMENT Aeonium 'Schwartzkopf Black Aeonium 5 gal 36" 36 2. THE CONTRACTOR MUST VERIFY THE LOCATIONS OF UNDERGROUND UTILITY LINES IN FIELD PRIOR RECOMMENDATIONS SUBMITTED TO THE OWNER'S REPRESENTATIVE A MINIMUM OF FIFTEEN ( 15) DAYS BEFORE AEOZWA TO ANY EXCAVATION, AND IS RESPONSIBLE FOR THE COST OF REPAIRING ANY DAMAGE. REQUEST COMMENCEMENT OF ANY PLANTING. AGAAME Agave americana 'Medio~picta Alba' Dwarf Variegated Century Plant 15 gal 48" 3 APPROVAL FROM LANDSCAPE ARCHITECT FOR ANY DEVIATION IN PLANT MATERIAL LOCATIONS. AGANOV Agave attenuata 'Nova' Blue Foxtail Agave 5 gal 36" 44 THE TESTING LABORATORY SHALL BE APPROVED BY THE OWNER'S REPRESENTATIVE. ( REFER TO SECTION 01630) ALY HUE Alyogyne huegelii 'Swan River' Blue Hibiscus 5 gal 48" 9 3. FINAL GRADES SHALL BE WITHIN TWO (2) INCHES BELOW CURB AND/OR PAVING GRADE IN SHRUB CAR BB Carissa macrocarpa 'Boxwood Beauty' Dwarf Natal Plum 5 gal 18" 625 AREAS, AND ONE (1) INCH BELOW CURB AND/OR PAI/ING GRADE IN LAWN AREAS. THE TESTING LABORATORY FOR SOILS ANALYSIS SHALL USE THE FOLLOWING CRITERIA FOR SOIL TESTING: USDA CEA YP Ceanothus griseus horizontalis 'Yankee Point' Yankee Point Ceanothus 1 gal 72" 276 AGRICULTURAL SUITABILITY TEST PER HANDBOOK 60, TO INCLUDE BORON PRESENCE AND CONTENT; AND UNIVERSITY 4. ALL TREES AND SHRUBS ARE TO BE REVIEWED AND APPROVED BY THE OWNER OR LANDSCAPE OF CALIFORNIA SOIL FERTILITY TEST. CON MAU Convolvulus mauritanicus Bush Morning Glory 4" pot 24" 571 ARCHITECT PRIOR TO INSTALLATION. COT DAM Cotoneaster dammeri 'Lowfast' Lowfast Bearberry flat 12" 11792 INTERPRETATIONS, FERTILIZATION AND SOIL AMENDMENT RECOMMENDATIONS, AND COMMENTS REGARDING THESE DOD VIS Dodonaea viscosa 'Purpurea' Purple Hopseed 5 gal 48" 18 5 ALL TREE DELIVERIES MUST BE COORDINATED WITH THE GENERAL CONTRACTOR. TESTS ARE REQUIRED. FESIDA Festuca idahoensis Idaho Fescue flat 12" 2850 FIC REP Ficus repens (staked) Creeping Fig 5 gal per plan 34 6. ALL TREE LOCATIONS ARE TO BE REVIEWED AND APP ROI/ED BY THE LANDSCAPE ARCHITECT PRIOR SOILS TEST SITES SHALL OCCUR NOT MORE THAN 250 FEET ON_CENTER IN THE PLANTING AREAS, UNLESS TO INSTALLATION. OTHERWISE NOTED ON PLANS. GAR JAS Gardenia jasminoides (grafted) Grafted Gardenia 5 gal 36" 62 HEU PP Heuchera 'Palace Purple' Purple Alumroot 1 gal 12" 23 7. ALL PLANTING PLANS ARE DIAGRAMMATIC, AND THE CONTRACTOR SHALL TAKE EVERY PRECAUTION SAMPLES OF ALL IMPORT SOIL FROM EACH SOURCE SHALL ALSO BE SUBMITTED TO THE SOILS TESTING LABORATORY LAM MAC Lamium maculatum Dead Nettle 1 gal 12" 77 TO ENSURE THAT THE ROOTBALLS OF NEWAND EXISTING TREES ARE NOT DISTURBED. FOR ANALYSIS, INTERPRETATION AND RECOMMENDATIONS PRIOR TO PLACEMENT, BLENDING OR BACKFILLING. LAU NOB Laurus nobilis Bay Laurel 15 gal 36" 40 LAV STO Lavandula stoechas 'Otto Quast' Spanish Lavender 5 gal 24" 128 8. ALL ON-CENTER SPACINGS FOR SHRUBS AND GROUND COVERS ARE TRIANGULAR SPACINGS. TEST RESULTS SHALL BE SUBMITTED TO LANDSCAPE ARCHITECT BEFORE DELIVERY OF SOIL AMENDMENTS. LEY CON Leymus condensatus 'Canyon Prince' Blue Wild Rye 5 gal 24" 22 9. ALL GROUND COi/ER SHALL EXTEND BENEATH ALL PLANT MATERIAL. MUH LIN Muhlenbergia lindheimeri Lindheimer's Muhly 5 gal 36" 9 OST FRU Osteospermum fruticosum African Daisy 1 gal 24" 105 10. ALL VINES AND ESPALIERS ARE TO BE REMOVED FROM STAKES OR TRELLISES AND ATTACHED TO PHO JS Phormium 'Jack Spratt' Jack Spratt Flax 5 gal 14" 53 WALLS WITH APPROVED DEVICES (SEE DETAIL). PHO PS Phormium 'Pink Stripe' Pink Stripe Flax 15 gal 42" 59 11. A MINIMUM OF 3" ORGANIC MULCH SHALL BE ADDED TO NON-TURF PLANTING AREAS WITH PHO TT Phormium 'Tony Tiger' Tony Tiger Flax 5 gal 20" 70 SLOPES LESS THAN 3:1 TO COVER THE SOIL SURFACE COMPLETELY. PIT VAR PIttosporum tobira 'Variegata' Variegated Mock Orange 5 gal 36" 34 RHA BAL Rhaphiolepis indica 'Ballerina' Dwarf lndain Hawthorn 5 gal 30'' 31 12 THE CONTRACTOR SHALL CONTACT THE LANDSCAPE ARCHITECT PRIOR TO BEGINNING ROS APP Rosa 'Appleblossom Flower Carpet' Appleblossom Flower Carpet Rose 5 gal 24" 29 LANDSCAPE WORK SO THAT LANDSCAPE ARCHITECT CAN REVIEW THE PROJECT UTILITY SAL LEU Salvia leucantha 'Midnight' Purple Mexican Bush Sage 5 gal 36'' 45 LOCATIONS AND REVISE PLANS ACCORDINGLY TO FULLY SCREEN ALL UTILITIES FROM VIEW. TRAJAS Trachelospermum jasminoides 'espaliered' Star Jasmine 15 gal per plan 6 VIBTIN Viburnum tinus 'Spring Bouquet' Laurustinus 15 gal 48" 33 WES FRU Westringia fruticosa 'Blue Gem' Coast Rosemary 5 gal 36" 24 *50% OF SHRUBS (EXCEPT ON SLOPES 31 OR STEEPER) SHALL BE A MINIMUM OF 5 GALLON SIZE MODEL SOIL PREPARATION & BACKFILL MIX SPECIFICATIONS: MULCH NOTE: THE FOLLOWING SPECIFICATIONS ARE TO BE USED FOR COST ALLOWANCES ONLY. FINAL SOIL ALL PLANTER BEDS ARE TO BE TOP DRESSED WITH MULCH UPON THE COMPLETION OF PLANTING OPERATIONS. MULCH SAMPLES PREPARATION AND BACKFILL MIX RECOMMENDATIONS TO BE BASED ON RESULTS OF REQUIRED SOIL SHALL BE APPROVED BY THE LANDSCAPE ARCHITECT PRIOR TO INSTALLATION OF THE MULCH. TESTS (REFER TO SPECIFICATIONS SECTION 02821, PAR. 1.04, E-1 THRU E-6 FOR SOIL TESTING REQUIREMENTS.) MODEL SOIL PREPARATION: (PER 1000 SQUARE FEET) ALLOW FOR A MINIMUM OF 4 CUBIC YARDS/1000 SQUARE FEET NITROGEN-STABILIZED ORGANIC AMENDMENT (AS SPECIFIED IN SECTION 02821, PAR. 2.01) SLOPE PLANTING GUIDELINES ALLOW FOR A MINIMUM OF 150#11000 SQUARE FEET 'GRO-POWER' 5-3-1 ALLOW FOR A MINIMUM OF 20#11000 SQUARE FEET SOIL SULFUR SLOPES 6:1 OR STEEPER AND LESS THAN 3' IN VERTICAL HEIGHT BROADCAST UNIFORMLY AND ROTOTILL INTO UPPER FOUR (4) TO SIX (6) INCHES OF SOIL. A STANDARD #1 -INSTALLATION OF GREEN FIX AMERICA'S WS05B BIODEGRADABLE ORGANIC NET STRAW MAT PER MANUFACTURER'S INSTALLATION AND FASTENING GUIDELINES MODEL BACKFILL MIX FOR TREES AND SHRUBS: (PER CUBIC YARD) 3 PARTS BY VOLUME NITROGEN STABILIZED ORGANIC AMENDMENT SLOPES 6:1 OR STEEPER AND 3' TO B' IN VERTICAL HEIGHT 7 PARTS BY VOLUME SITE SOIL 20# 'GRO-POWER 5-3-1' PER CUBIC YARD OF MIX A STANDARD #1 -INSTALLATION OF GREEN FIX AMERICA'S WS05B BIODEGRADABLE ORGANIC NET STRAW MAT PER MANUFACTURER'S INSTALLATION AND FASTENING GUIDELINES MODEL BACKFILL MIX FOR RHODODENDRONS, AZALEAS AND/OR CAMELLIAS: (PER CUBIC YARD) B. STANDARD #2 -COTON EASTER DAM MERI 'LOWFAST' GROUND COVER TO BE PLANTED FROM A MINIMUM OF FLATS AND 12" ON CENTER SPACING 1/3 BY VOLUME -PRE-MOISTENED SPHAGNUM PEAT MOSS C. STANDARD #3 -CEANOTHUS GRISEUS HORIZONTALIS 'YANKEE POINT' TO BE PLANTED FROM A MINIMUM 2-314" LINER AND 6' ON CENTER SPACING 1/3 BY VOLUME -APPROVED TOPSOIL 113 BY VOLUME -AMENDED SITE SOIL 10#-'GRO-POWER 3-12-12 FLOWER & BLOOM' FERTILIZER PER CUBIC YARD OF MIX SLOPES 6: 1 OR STEEPER AND IN EXCESS OF 8' IN VERTICAL HEIGHT 3# -'GRO-POWER PREMIUM GREEN IRON -40% Fe' PER CUBIC YARD OF MIX A STANDARD #1 -INSTALLATION OF GREEN FIX AMERICA'S WS05B BIODEGRADABLE ORGANIC NET STRAW MAT PER MANUFACTURER'S INSTALLATION AND FASTENING GUIDELINES MODEL BACKFILL MIX FOR PERENNIALS AND ROSES (PER CUBIC YARD) B STANDARD #2 -COTONEASTER DAMMERI 'LOWFAST' GROUND COi/ER TO BE PLANTED FROM A MINIMUM OF FLATS AND 12" ON CENTER SPACING 113 BY VOLUME -PRE-MOISTENED SPHAGNUM PEAT MOSS 213 BY VOLUME -AMENDED SITE SOIL C. STANDARD #3 -CEANOTHUS GRISEUS HORIZONTALIS 'YANKEE POINT' TO BE PLANTED FROM A MINIMUM 2-314" LINER AND 6' ON CENTER SPACING 10#-'GRO-POWER 3-12-12 FLOWER & BLOOM' FERTILIZER PER CUBIC YARD OF MIX D. STANDARD #4 -MELALEUCA NESOPHILA SMALL TREES TO BE PLANTED FROM A MINIMUM OF 1 GALLON CONTAINERS AND SPACING PER PLAN AT A MINIMUM RATE OF ONE (1) PER TWO HUNDRED (200) SQUARE FEET AREAS GRADED FLATTER THAN 6:1 AND NOT SCHEDULED FOR IMPROVEMENT WITHIN 6 MONTHS OF COMPLETION OF ROUGH GRADING, HAVE POTENTIAL EROSION PROBLEMS AS APPLICATION RATE TABLE DETERMINED BY THE CITY, AND/OR ARE IDENTIFIED BY THE CITY AS HIGHLY VISIBLE AREAS THAT WARRANT IMMEDIATE TREATMENT SHALL BE PLANTED WITH S&S SEEDS' BASIC NATIVE EROSION CONTROL MIX APPLIED VIA THE MANUFACTURER'S INSTALLATION GUIDELINES GRO-POWER 7 GRAM PLANTING TABLETS, 12-8-8 with 20%%% Humus and 4%%% Humic Acid Plant Size 1 Gal 2 Gal 5 Gal 15 Gal 20"-24" Specimen Trees Plant Plant Plant Plant Box & Shrubs # ofTablets 2 3 6 12 15 4 Tablets for every APPROVED roR inch of Caliper Note: Place tablet(s) no higher than 1/3 of the way up the rootball spaced equally around the perimeter of the rootball !RR/GA TION AA/D PLAA!TING approximately 2" from the root tips. OA/L Y, INCLUDING PRECISE LOCA TIOA/ or PLANTIA/G AREA. 11 (c-,S BUIL T 11 NOTE WELL: RCE EXP. DATE NO EXCAVATION OF ANY KIND IS TO OCCUR ANYWHERE ON SITE WITHOUT FIRST VERIFYING THE LOCATIONS OF REV!Ev/ED BY, EXISTING UNDERGROUND UTILITIES. !~!SPECTOR DATE 12.10.13 CB /t\ REI/I SION ~ CITY OF CARLSBAD SHEETS 01.13.14 CB 0. REVISION 01.21.14 CB 1:'J\ REI/I SION . PLANNJNG D[l/[S!□N 20 LANDSCAPE: IMPROVEMENT PLANS f'OR: I AM FAMILIAR WITH THE REQUIREMENTS FOR BUENA VISTA 11 LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE ---------- CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER r:i""'' ~. SHt~UB AND GRDUNDCDVER PLAl'IT ING NOTES EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED CJ, THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS 1/ 9 ~ I APPROVED: ~\ Cr: ~)""""tt I -0 -t,,r.:,, 1--t AND THE LANDSCAPE MANUAL AND AGREE TO COMPLY ,, ., f';:;"'1,::,, WITH ALL REQUIREMENTS WHEN SUBMITTING · \ , _±,TW1'f PLANNING CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN \,fl,,>,~ ...._"t: DWN BY: CB PROJECT NO. DRAWING NO. IMPLEMENTS THOSE REGULATIONS TO PROVIDE "lj', ..... ....__ '?,. ........ DATE INITIAL DATE INITIAL DATE INITIAL CHKD BY: ~ -,-() REVISION DESCRIPTION CT 13-01 479-6L EFFICIENT USE OF WATER." '-..,Of;CA\..\( DESIGNEF~ OF WORK OTHER APPROVAL CITY APPfWVAL RVWD BY: -.... ----- SECTION/ ELEVATION ~-------BOXED SPECIMEN TREE CENTERED IN PIT AND VERTICAL ~---PLACE CROWN OF ROOTBALL 1" MIN./ 2" MAX. ABOVE SURROUNDING FINISH GRADE -----EARTHEN WATERING BASIN -RAKE OUT BEFORE PLANTING LAWN OR GROUND COVER ------WATER-SETTLED PREPARED BACKFILL MIX -REFER TO SOIL REPORT, NOTES AND SPECS --------FINISH GRADE 7"~:1/~~·~-:_--------'GRO POWER' PLANT TABLETS -SEE "' · · m NOTES AND SPECS FOR PROPER . mff QUANTITIES AND PLACEMENT -r . illt---------UNDISTURBED OR COMPACTED . '· · ·' l[[l;c SUBGRADE TT =[TI= -• ,' 18" MIN. (TYP.) NOTE: REFER TO GUYING DETAIL IF GUYING IS REQUIRED 0 SPECIMEN TREE PLANTING N.T.S. '.l9')S'.l-021 ---------TYPICAL CONTAINER GROWN OR 24" BOX TREE CENTERED IN PIT AND VERTICAL ~----PLACE CROWN OF ROOTBALL 1" MIN./ 2" MAX. ABOVE SURROUNDING FINISH GRADE -------BARK MULCH -MIN. 1" DEEP, MAX. SIZE 1", REFER TO NOTES AND SPECS --------EARTHEN WATERING BASIN -RAKE OUT BEFORE PLANTING TURF OR GROUND COVER, OR AS DIRECTED ---------FINISH GRADE -r-• i-~ ll 111 ill l) 0 Ill () ~ O' 3 IL I-() SECTION/ ELEV ATlON TREE PLANTING 5 & 15 GAL./24" BOX I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER." NOTE: REFER TO SPECS FOR STAKING REQUIREMENTS N.T.S. ---------------MIN. 3 GUYS, EQUALLY SPACED 120" AROUND TREE 1 --------------THIS DIMENSION SHOULD BE APPROXIMATELY q_ · }, EQUAL TO THE HEIGHT OF ATTACHMENT 0;:: ✓--I ROOTBALL LIMIT -'~ II/--. ~--------------..... r \ PLANT PIT LIMIT I I · \ I \ \ 'q:"~-------------POSITION TIES FOR MUL Tl-TRUNK TREES AS SHOWN ~-/ / ~ BELOW '-..._ _ _. 2" X 2" X 36" LONG, BURIED REDWOOD STAKE, TYPICAL az1-, - N :E -,------.---- PLAN VIEW '---------------EDGE OF PAVING OR WALL ----------TYPICAL BOXED SPECIMEN TREE --------~ TYPICAL TREE TIES -ATTACH TO MAJOR BRANCHES ONLY, TIES SHALL BE 5/8" DIA. GARDEN HOSE WITH /J'12 GAUGE GALVANIZED WJRE, DOUBLE STRAND --------PROVIDE WHITE PLASTIC TUBING OVER GUY WIRE ~-------TURNBUCKLE AT FINISH GRADE, ADJUST TO TAKE UP SLACK ONLY ~------ANCHORS-2" X z~ X36" LONG REDWOOD STAKES, INSTALL MIN. 1" BELOW FINISH GRADE -------EDGE OF PAVING NOTE: GUYING OF BOXED SPECIMEN TREES IS LEFT TO THE CONTRACTOR'S DISCRETION DEPENDING ON BRANCHING STRUCTURE AND WIND EXPOSURE. THE lPJ'.IDSCAPE ARCHITECT RESERVES THE RIGHT TO MAKE THE FINAL DECISION REGARDING GUYING REQUIREMENTS. 0 SPECIMEN TREE GUYING N.T.S. 0 -------------------'WONDER TIE' #B-18 OR 'V.1.T. BRACE' INSTALLATION \--------------WRAP WIRE AROUND STAKE AND SECTION/ ELEV ATlON TREE STAKING DOUBLE STAKE SECURE PARALLEL TO BACK OF STAKE WITH 3/4" STAPLES FOR 'WONDER TIE', WITH 4 GALVANIZED NAILS FOR 'V.I.T. BRACE' N.T.S. 'J'J'J')'.)-016 ~--------------ADJACENT PAVING -----------PLANTING AREA ~--------FINISH GRADE ~---PROPOSED TREE BIOBARRIER AVAILABLE FROM: REEMAY, INC. 70 OLD HICKORY BLVD. OLD HICKORY, TN 37138 PHONE: 800-284-2780 FAX: 615-847-7068 '-------------SOIL BACKFILL SECTION I ELEVATION BIOBARRIER NOTE: INSTALL PER THE MANUFACTURER'S RECOMMENDATIONS N.T.S. FOR TREES PLANTED WITHIN 5' OF HARDSCAPE 'n<J<J<J-12:Jpt ~------------------ON SLOPES GREATER THAN 3:1, INSTALL JUTE MESH ON UPHILL SIDE OF PLANT PIT, SECURE AT ALL EDGES ~----------------MAXIMUM 1:1 SLOPE ~---------------LINE OF ORIGINAL GRADE SECTION I ELEVATION ~----TYPICAL CONTAINER GROWN OR 24" BOX TREE, CENTERED IN PIT AND VERTICAL ~---SET CROWN OF ROOTBALL LEVEL OR SUGHTL Y ABOVE FINISH GRADE WITH CORNER OF ROOTBALL AT LINE OF ORIGINAL GRADE ------3" MIN. COMPACTED SOIL BERM - INSTALL JUTE MESH ON ALL SLOPES GREATER THAN 3:1, SECURE TO SLOPE PER MANUFACTURER'S RECOMMENDATIONS --------'GRO POWER' PLANT TABLETS -REFER TO NOTES AND SPECS FOR PROPER QUANTITIES AND PLACEMENT '--'--------WATER-SETTLED PREPARED BACKFILL MIX -REFER TO SOIL REPORT, NOTES AND SPECS. COMPACT FIRMLY UNDER ROOTBALL TO AVOID SETTLING ~------UNDISTURBED OR COMPACTED SUBGRADE NOTE: REFER TO SPECS FOR STAKING REQUIREMENTS TREE PLANTING ON SLOPES 5 & 15 GAL./24" BOX N.T.S. ')'J<J~')-018 APPROVED FOR /RR/GA TION A/\/O PLA/\ITl/\!G O/\/L Y, 1/\/CLUDING PRECISE LOCATION OF PLA/\ITI/\/G AREA. EXP, ___ _ DATE REV !E'tlED BY, DATE 1;1.1c.1.o ::!J firVl'ilON ~ C' .. l'l'Y' 01;1 C' ,1.u1,s·.8f'' 'D µ~c.:' 1"-. l'-'.'5"-. ,_I·_· f--"'::..eUc_µ;p.'lccil~· ''-'il"'SeclO,._~,_I --------------+---l---+----1----I , l' .C-i l \. _-i :, 1.) 1. 1.: :. Ii rd \/l'ilON PLANNING DIV IS ION =='....'=========:::::::::::::========='-=== LANDSCAPE LIIPFWVC.\ll:N'I' PLANS !''OR BUENA VISTA 11 PLANTING DETAJLS ,IPPROI/ED: /t ~ G(, 8 ko :1t -z.. (:.., 1-t PLANNING REVISION DESCRIPTION OWN BY: r: R PIWJEC T NO. cr~-\\,1/ING 1\,J, DATE INI rl/\L DATE INITIAL CHKD BY: 479-6L 0TrlcR APPR0\/AL CITY APPROVAL r<VWD B 'I: CT 13-01 ~------:::::::::;::---------'CINCH TIE' INSTALLATION ,/ ~••= 'WONDER TIE' #A-12 INSTALLATION OR HOSE AND WIRE TIE , ,,--WRAP WIRE AROUND STAKE AND mec "'"' / SECURE PARALLEL TO BACK OF STAKE WITH 3/4" STAPLES FOR 'WONDER TIE' :----------------LODGEPOLE PINE STAKE -2" DIA X 12' LONG. PLACE STAKE ON WINDWARD SIDE MIN, 8" FROM TRUNK, DO NOT ALLOW STAKE TO PENETRATE ROOTBALL /1;,oi,,.,.lff-------------'GRO POWER' PLANT TABLETS -RicFER ill =.;41 E TO NOTES AND SPECS FOR PROPER ,!]°"'/><.~"/ n:,,,~,J,;r/ ""''' [ QUANTITIES AND PLACEMENT ·ITT=-, , i ~if!a,~!JF-1 ~ _ NOTE: TIES SHALL BE (1) 'WONDER TIE' #A-12 BY ALDEN = ENTERPRISES, OR __________ v (2) 'CINCH-TIE' BY V.1.T. COMPANY, OR 0 SECTION/ELEVATION (3) 1/2" DIA, GARDEN HOSE WITH #12 GALVANIZED WIRE, MIN, 18" LONG TREE STAKING ON SLOPES SINGLE ST AKE ------------TYPICAL SHRUB CANOPY -----------GROUNDCOVER TO EXTEND TO 2/3 UNDER CANOPY OF SHRUBS N,T.S, 9'J'J'J9-0l◄ ~ + 1 ------TYPICAL TRIANGULAR SPACING -REFER TO PLANT SPACING CHART BELOW ·> + + "A" "B" ·c· + PLANT SPACING ROWSPACJNG SETBACK 12" 10-1/2" e· > + + > + 16" 14" H" 18" 15-1/2" 9" 24" 21" 12· l'LAN ----------------EDGE OF WALK, WALL, CURB, HEADER OR BUILDING FACE ----------------TYPICAL SHRUB CANOPY , ~-----------fYPICAL GROUNDCOVER ROW SPACING AND ' / I SETBACK, REFER TO CHART ABOVE ·s· ·c· r-rj MULCH, MIN. 1" DEEP NEAR PLANTS AND HARDSCAPE, 3' {1 / DEEP IN ALL OTHER LOCATIONS, MAX. SIZE 1" ·17tf6~?{ '§cf'//;; ' "• =/-PLANT PIT MIN. 4" X 4" /j~:,flll:=;1J._Fml ,,,--AMENDED SOIL PER SOIL REPORT RECOMMENDAf!ONS I -in I AND NOTES , CANOPY GROUNDCOVER PLANTING I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING CONSTRUCTION DOCUMENTS, I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER." N.T.S. 9<J<J<J<J-026 SECTlON/ELEVATlON CONTAINER GROWN SHRUB SET CROWN LEVEL OR MAX. 1" ABOVE SURROUNDING FINISH GRADE ----BARK MULCH -MIN, 1" DEEP, MAX. SIZE 1 ", REFER TO NOTES AND SPECS ~---EARTHEN WATERING BASIN -RAKE OUT BEFORE PLANTING TURF OR GROUND COVER, OR AS DIRECTED -----FINISH GRADE ------'GRO POWER' PLANT TABLETS -SEE NOTES AND SPECS FOR PROPER QUANTITIES AND PLACEMENT SHRUB PLANTING N.T.S. v + ·> + + + + + + + ·> + PLAN SECTlONS ' + ~-----------TYPICAL SHRUB CANOPY -----------GROUNDCOVER TO EXTEND TO 213 UNDER CANOPY OF SHRUBS 'J<J<J<J<J-023 ------TYPICAL TRIANGULAR SPACING -REFER TO PLANf SPACING CHART BELOW + "A" "B" ·c· PLANT SPACING ROWSPAC!NG SETBACK 8" 7-1/4" 5• + 12' 10-1/:.!" 6" 16" 14" a· . '~ I + '1/ + ~--1, ·" . ~ ~ "A' ·t -1 l.) 18" 15-1/2'' 9' 24" 21" 12· ........ -~. ----------------EDGE OF WALK, WALL, CURB, HEADER OR BUILDING FACE GROUNDCOVER PLANTING ON SLOPES N.T.S. 01190-llp! --- ~,C#~ rt ,;,. '{\ fiij/"6-. ·~\~~-" , ... .y ;-':----.... ~ (:" --.;eQ~ '-..':_ F G ,-, \. V ·-- l'.'.10,1.l CG 01.1.5.1 t := 8 Ul.l I. I : ~ [3 U-\ ·1 \' Al D~ :;:.,~.,\~-;:.: C • N(J~r< ~------------------ON SLOPES GREATER THAN 3:1, INSTALL JUTE MESH ON UPHILL SIDE OF PLANT PIT, SECURE AT ALL EDGES ~-----------------MAXIMUM 1:1 SLOPE ~-----------------LINE OF ORIGINAL GRADE --------TYPICAL SHRUB ----SET CROWN OF ROOTBALL LEVEL OR SLIGHTLY ABOVE FINISH GRADE WITH CORNER OF ROOTBALL AT LINE OF ORIGINAL GRADE ~-----3" MIN, COMPACTED SOIL BERM - INSTALL JUTE MESH ON ALL SLOPES GREATER THAN 3:1, SECURE TO SLOPE PER MANUFACTURER'S RECOMMENDATIONS ~------'GRO POWER' PLANT TABLETS -REFER TO NOTES AND SPECS FOR PROPER QUANTITIES AND PLACEMENT SECTION/ELEVATfON SHRUB PLANTING ON SLOPES N.T.S. 99999-0!'J ~-----CRIMPS AT EACH END ELEVATION WALL ELEVATION FOR VINES AND ESPALIERS EYE BOLT TYPICAL -SEE DETAIL NOTE: STAINLESS STEEL WIRE TO RUN CONTINUOUS FROM TOP OF WALL TO BOTTOM. DO NOT DOUBLE UP LINE BETWEEN EYE BOLTS. ADJUST LINE AT EDGES FOR EXTRA SLACK, SCALE: 3/8" == 1'-0" 9<J9'J'J-JJ4pl APPROVED !RR/GA T!ON AND ONLY, INCLUO/(\/C FOR PLAN T/(\/G PRECISE LOCA T/0(\/ OF PLAN T/(\/G AREA. 11 AS BUILT'' RCE EXP, DATE REV!E1t!ED BY, INSPECT□r, De\TE /1\ f,EI/ISION SHEET Cl'l'Y OF' CA1~LS.BAD SHl[-,-:i /2' I,E\/ISION ,,(\ f!EVISIO~I 18 PLANNING DIVISl □N 20 LANDSCAP8 LllPfW\18,IICN'l' PLANS l·'OH: BUENA VISTA 11 PLA~IT ING DETAILS I APPROVED: nJl 4 LllJr -z. (.,.(:j_ PLANNl~G DWN G Y: CR PfWJLC. NO, UH-IWING 1\:J. D •\ TE l,\Ji rlAL LIATE I/\IITl•\L CHKD uv: F~EV S.Of\ DESC f<l :o TION CT 13-01 479-6L OTHEq APPROVAL CI TY APPROVAL F!VWU B '!: I I I ~----------------STONE OR STUCCO WALL ~------------VINE OR ESPALIER - ~ (1/' \l l ~ vi /~------------BRASS EYE BOLT J\' / Fl ~---------~VINYL COATED WIRE TIE /-~/~1/ I ~ ' __ / ~■----1-11 --------------PLASTIC ANCHOR-MATCH ANCHOR SECTJON WALL ATTACHMENT FOR VINES AND ESPALIERS I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER." COLOR TO SURFACE COLOR (PLASTIC ANCHORS ARE NOT REQUIRED WHEN ATTACHING TO WOOD POSTS.) NOTES: • EYE BOLT PLACEMENT TO BE DETERMINED IN THE FIELD BY THE OWNER'S REPRESENTATIVE OR THE LANDSCAPE ARCHITECT. • REMOVE ALL VINES AND ESPALIERS FROM NURSERY STAKES OR TRELLISES AND ATTACH TO SUPPORTS AS SHOWN N.T.S. O/l~0-12pl I?. lC.13 ._I 1 . ] ~. 1 ·. ._1171.1: '._' !j /i\ ,<CVISION I~ 1,,v1s10,1 A lff\/lSION SHU" C 19 APPROVED FOR !RR/GA T!ON A!\/O PLA/\I Tlf\!G O/\/L Y, /f\/CLUO/f\/G PREC'/SE LOCA T!ON OF PLANTING AREA. ''AS BUILT" PCE __ _ EXP. ___ _ DATE PEV![',/EO BY, INSPECT□P DATE Cl'l'Y OF' CJ-\F?LSBJ\D PLANNING DIVISI □N LANUSCAl0 C: IMPIWVC_\lr:N'l' l-'LANS F'OK .--------------:-----i---+--1-----------------+----l----l---J----l BUENA VISTA 11 _, ... ~ :·· ~ . ~\;: ,,,T '-I! .... __ ,, o'<- .........._, of: cA\..\c '--...::..:::;,.-, PLANT l~IG DETAILS '-----i,----+----------------l----+-----+---+----11-A-PP_R_o_v_E_D_'---'-~7t~1--==-----"==.J.l---'------I • /~--k", C:f· t:tl...oJL -z,. "'· r-t J----ll-----+----------------1----+-----l----1-----I ~P::::LA::::~=:IN=:IN::::G====:;-;========:::;-;:::--=--=--=--=-=-=-=-=~- D w,1 B Y: -----'-r""". RL_ CHKD EJY: __ _ RVI//D BY: REVISION DESC RiPTION OA TE INI rlAL DATE INI rJAL OTHER APPROVAL C i"!"Y ,-\PPROVAL Pt<OJEC: NO. CT 13-01 ur!-\WIN::; 1\0. 479-6L ' I I I I I I, I I I / / • / / / I / / / ..::::..• ► f f I I I I 'i' I f I I f I I I I I \ \ \ \ \ \ \ \ \ \ \ /). • \ 1....,_/ \~------\-___:\-~~\\ \ \ \ \ ~-\ -"" -----" \ -----" -'?-\ >-J'"--..0' \ LIGHTING MANUFACTURER'S LIST SPJ LIGHTING, INC. 2107 CHICO AVENUE SOUTH EL MONTE, CA 91733 WWW.SPJLIGHTING.COM CONTACT: CHRIS GONZALEZ EMAIL: CHRIS@SPJLIGHTING.COM TELEPHONE: 800-469-3637 CELL: 213-216-2190 FAX: 626-433-4839 I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINED IN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPE REGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS AND THE LANDSCAPE MANUAL AND AGREE TO COMPLY WITH ALL REQUIREMENTS WHEN SUBMITTING CONSTRUCTION DOCUMENTS. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TO PROVIDE EFFICIENT USE OF WATER." I \ \ \ ,1 • <1, \ \ \ \ \ \ /),: C LIGHTING LEGEND SYMBOL FIXTURE (NAME OR STOCK NO.) ~t.r--SPJ-MR. UNIVERSE 3900K UPLIGHT -$-SPJ-MW1000-P-3900K-MBR WELL LIGHT ' SPJ-CC-102-LED '-EB-MULTITAP PROFESSIONAL MTP 300T 300 WATT TRANSFORMER 4• NUMBER OF FIXTURES 26 4 2 AS NEEDED 8 ' ~ • <--117 \ 4 • ve· <--1 BULB WATTAGE & TYPE TYPE OF MOUNT 3WATT STAKE LED ?WATT IN-GROUND LED 3WATT STAKE LED 300 WATT MOUNT LOCATIONS TO BE LOW VOLT TRANSFORMER DETERMINED 8 15 24 -----· '----~ SCALE: 1/8"=1'-0" \ \ 1/.10. 13 C8 <l <l t, <l -\ \· \ L • • <l L) t, < \ < L L /_ \ -CJ 0 ~ () rn TREE SYMBOLS e PROPOSED TREE NOTE WELL: LIGHTING NOTES: 1. INSTALLATION SHALL BE PER ALL APPLICABLE CODES. 2. ALL FIXTURE LOCATIONS SHALL BE APPROVED AT A NIGHT SET WITH THE OWNERS, THE LANDSCAPE ARCHITECT, AND THE LIGHTING INSTALLATION CONTRACTOR 3. ALL CABLE, CONDUIT AND TRENCHING SHALL NOT CONFLICT WITH PLANTING PLANS, NOR DISTURB THE ROOT ZONES OF ANY EXISTING OR PROPOSED TREES. ALL CABLE SHALL BE INSTALLED PER THE GOVERNING CODES. 4. FIXTURES AND TRANSFORMERS LOCATED IN THE FIELD BY THE LIGHTING INSTALLATION CONTRACTOR AND SHALL BE APPROVED BY THE LANDSCAPE ARCHITECT. THESE DRAWINGS ARE DIAGRAMMATIC . 5. ALL LOW VOLTAGE LIGHTING TO BE CONTROLLED BY A DIMMER. ALL FOUNTAIN LIGHTS TO BE CONTROLLED BY A DIMMER. 6. THE LANDSCAPE LIGHTING CONTRACTOR SHALL BE PREPARED TO LAMP ALL FIXTURES WITH VARIOUS LAMPS OF DIFFERENT WATTAGE. THE UPLIGHTS SHOULD BE SET TEMPORARY FOR A NIGHT SET WITH THE OWNER AND THE LANDSCAPE ARCHITECT. THE FINAL FIXTURE LOCATION AND LAMPS WILL BE DETERMINED AT THIS NIGHT SET. 7. REFER TO ELECTRICAL ENGINEER'S DRAWINGS FOR ALL ELECTRICAL ENGINEERING. 8. LIGHTING CONTRACTOR TO PROVIDE 5' OF COILED CABLE AT ALL LOW VOLTAGE LIGHT FIXTURE LOCATIONS TO BE ABLE TO MOVE EACH FIXTURE IN ANY DIRECTION 9. ELECTRICAL INSTALLATION CONTRACTOR TO COORDINATE ALL WIRE SIZING, NUMBER AND SIZING FOR TRANSFORMERS WITH AN ELECTRICAL ENGINEER. 10. SYSTEM CIRCUITING TO BE COORDINATED WITH THE OWNER'S REPRESENTATIVE, ELECTRICAL ENGINEER AND THE LANDSCAPE ARCHITECT. 11. SHRUB PLANTING SHALL BE ADJUSTED IN THE FIELD TO PROVIDE CLEARANCE AND ACCESS TO LANDSCAPE LIGHTING TRANSFORMERS PER LOCAL CODES. APPRO \/[0 FOR !RR/GA T!ON ANO PLAAITING OA!L Y, INCLUDl!\/G PRECISE LOCA TIOA/ OF PLANTING AREA. f<CE ___ EXP, ___ _ DATE NO EXCAVATION OF ANY KIND IS TO OCCUR ANYWHERE ON SITE WITHOUT FIRST VERIFYING THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES. REV IE'JED BY: INSPECTOR DATE 1 REVISION Ul.l.i.1·' CEJ fff\/lSION Cl'I'Y OF' CJ\.RLSBAD SH[E-', -1---"-''--+-'-',-:,..C""-==--------------l-----l----l-----1-----1 0 )0 ==='-'===::::::::P::::L:::::A:::::N:::::N::::I '':::::IG::::::::D::1 ::::V::::I S::::1::::0:::::N====-'====='. .Jl.)1.1·' (~ G fsE\/ISION LANDSCAPf: IMPfW\IC,\JE:N'I' Pl.ANS F'OR: BUENA VISTA 11 LANDSCAPE LIGHTING PLAN -LDT 1 MODEL ,\PPROVED: PLANNl~G D~\ fE l,\JI TIAL 01-\ I[ OTHER A~PROVAL CI TY ~\PPROV~\L OWN B V: I' R C:HKD BY: __ _ r,vwD 0·1: fJfWJf_;; . ~O. CT 13-01 479-6L