Loading...
HomeMy WebLinkAbout5815 EL CAMINO REAL; ; FPC2021-0045; PermitPERMIT REPORT Fire Permit Print Date: 11/03/2021 Job Address: 5815 EL CAMINO REAL, CARLSBAD, CA 92008-8801 Permit Type: FIRE-Construction Commercial Work Class: Parcel#: 2120621200 Track#: Valuation: $0.00 Lot#: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Description: FARMERS BUILDING -SPRINKLER MONITORING REPLACEMENT Applicant: STANDARD ELECTRONICS JESUS LEDEZMA 9340 STEVENS RD SANTEE, CA 92071-2810-SAN DIEGO (619) 596-9950 FEE FIRE Sprinkler Monitoring Fire Alarm Total Fees: $383.00 Total Payments To Date: $383.00 Fire Department {_ City of Carlsbad Permit No: FPC2021-0045 Status: Closed -Finaled Applied: 04/06/2021 Issued: 04/15/2021 Finaled Close Out: 11/03/2021 Inspector: Final Inspection: FPContractor: STANDARD ELECTRONICS 9340 STEVENS RD SANTEE, CA 92071-2810 (619) 596-9950 Balance Due: AMOUNT $383.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov SUB MITT AL SHEET PROJECT: Old Farmers Ins Bldg 5815 El Camino Real, Carlsbad, CA 92008 ELEC.CONTR: City of Carlsbad Public Works 405 Oak A venue, Carlsbad, CA 92008 ITEM QTY 1 1 2 1 3 1 4 2 5 1 6 1 7 8 8 lK 9 .8K DESCRIPTION EQUIPMENT Sprinkler Monitoring Fire Alarm Document Storage Box Fire Alarm Control Panel SFM#7l65-0559:0501 Cellular Communicator SFM#7300-l 157:0136 12 Volt 7 AH Sealed Lead Acid Battery Addressable Pull Station SFM#7150-0559:0161 Addressable Smoke Detector SFM#7272-0559:0149 Addressable Mini-Monitor Module SFM#7300-0559:0155 2 conductor, 16 AWG, Unshielded, Jacketed 2 conductor, 16 AWG, Unshielded, Jacketed, Underground MODELNO. SSU00690 6700 CELLCOMF-LTI ES7-12 SK-PULL-DA SK-PHOTO SK-MINIMON D162F H2+162 RED March 30, 2021 DATA SHEET Space Age Silent Knight DMP MK Battery Silent Knight Silent Knight Silent Knight wcw wcw Standard Features: • Installed with a 4 GB digital flash drive with USS B connector • 2 key ring hooks to hold system keys • Business card holder for key contacts • Overall dimensions are 12" x 13" tall and 2 1 /4" deep • 18 gauge steel box and cover for security • Durable powder coat baked on finish other colors available • Standard 3/4" cat 30 key lock. Other lock assemblies available • Solid stainless steel piano hinge • Permanently screened white ink 1" high "SYSTEM RECORD DOCUMENTS" • Legend sheet for documentation, passwords and system information SRD ACE-11 SYSTEM RECORD DOCUMENTS The SRO is the perfect item to help you meet demanding code requirements today. NFPA 72 2013 7.7.2.4 states that a cabinet must be "prominently labelled 'SYSTEM RECORD DOCUMENTS'." The SRO is the perfect fit to meet todays demanding code requirements. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2013 7.7.2.1 states, "With every new system, a documentation cabinet shall be installed at the system control unit or other approved location at the protected premises." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the software not being on site when technicians arrive to service the system. Along with your fire alarm software you can store your test & inspection, service records, manuals & system records. Using a standard USB B connector you may also store you records electronically (See NFPA 72 2013 7.5.6.7). The SRO has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has an organized record for identifying equipment information, required documentation locations (See NFPA 72 2013 7.2.1). II] NErlll ~ R • Made In~. r-r11.Jaan Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax NFP~ IMEIIIBER Space Age Electronics, Inc. 2013 ED0584 L T10641 Rev.A 1/2 No Excuses, Just Solutions! EL~b,-~~N?c~~E. / Specifications: The system record documents box (SRO) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cov~r shall be permanently screened with 1" high lettering "SYSTEM RECORD DOCUMENTS "with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1 /2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The SRO will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface ~ Requires Standard USB-8 Connector Key Ring Hooks For--onle<-EA0318(0ty.10) Property Information =property: __ _ ~noff)fOPNt;: __ _ Occuponcylype: __ _ Certtllcatlons and Approvals 16.1 System Installation Com-actor: llnll)'MM\,Hapte&d,,.,._,,,...,..ninltaltdand lntadaecordlf'GIOalNF~-ncllrdldtilc:lherffl. :~· ..... -, -- Dtt«_/~ =-~--- 16.5 Authority Having Jurisdiction: lhlwwllnnMdaMhflc:10fyacaptance1Ntolllil syamandflndl"bentalldandoperatil"Gp,operty lnacx:onllncewltlllappoYedpllirwarw:tapecillcalonl, =:-.:.:::::op..-atlora, andwlh 11 Equipment Information E:~codo-. ..::::::-~_-_-_ J SpoooAQO-lnc:. Minimum Required Documenc.tlon (SIG-FUN) (fWl,.nceNF~7220138Ktlon7.2.1) 1 ~:~~~OC::,aysa_m ______ _ 2RINrd.,am oNIA aEncioNd OrAlt.Locetlon _____ _ •~•~~~operdonandrnahwnanctk'lltructbn •~.r.==~=Mlnglntccofdancewth7,l.land7.8.2 110~-=-~~=rwadocUmenl:ationln1cc:ordlnce...,s.c:dotl7.e Otte:_,_,_ Ston.,g.MA01!5G< ~1723 Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Ordering Information: ~ Part# Description ' ~ SSU00689 System Record Documents Cabinet RED Space Age Electronics, Inc. SSU00690 Custom screening with your Logo www.lsae.com soo.486.1 723 Toll Free EA0315 10 pack door legend sheet 508.485.0966 Local 508.485.4740 Fax This document is subject to change without notice, see doc# ED0479 for legal disclaimer No Excuses, Just Solutions! ED0584 LT10641 Rev.A 2/2 HOneywe I Addressable Fire Alarm Co ntrol Panels msn.err 6700 ~ Ad dressable Fire Alarm Contro l Panel The 6700 is an addressable fire alarm control panel (FACP) that is a direct replacment for the 5700 FACP. The 6700 can be configured to achieve a point capacity of up to 100 points. It has one built-in signaling line circuit (SLC), which can support 50 System Sensor® (SK) sensors and 50 SK modules or 50 Hochiki® (SD) devices. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single-point communications. The 6700 also has a built-in, dual-line POTS and IP communicator with additional cellular options available. The 6700 system can be enhanced by adding modules such as the 6860 remote annunciator which also has four programmable function buttons to help automate tasks and reduce time spent at the panel. SWIFT® wireless compatibility provides options for wireless detection through a Class A mesh network. It is ideal for hard-to-wire locations, buildings where new wiring is not allowed, or to provide an easy install fire system for new construction projects. SWIFT devices can be combined with other hard-wired 6700 compatible devices.SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. The 6700 also has a form-C trouble relay, two programmable form-C relays, along with powerful features such as drift compensation, pre- trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and calibration trouble alert. FEATURES & BENEFITS • Capable of providing up to 100 points to satisfy smaller installation needs • Connect up to 17 panels on one site with convenient single- point access using the SK-NIC Network Interface Card. Connected panels can have mixed compatible FACP models • Convenient field-upgradeable firmware • Built-in dual path POTS and IP communications with optional cellular models available for reliable backup reporting • 6860 annunciator with a 4 x 40 large display • Four user- programmable buttons minimize time spent executing complex or routine tasks • Built-in USB interface for convenient and quick programming 6700 The 6700 supports a variety of devices, including the 6860, 5860, and 6855 remote annunciators, 5824 serial parallel printer interface module (for printing system reports), the 5496 NAC expander, 5895XL power module, and SK or SD devices. • Programmable date setting for automatic and convenient Daylight Saving Time changes • JumpStart® auto programming reduces installation time • 125 software zones and 125 output groups for flexible design options SIGNAL LINE CIRCUIT (SLC) The 6700 SLC loops support multiple device types, maintenance alerts, and a built-in sensor test to comply with NFPA 72 calibration testing requirements. INDICATOR LIGHTS • General Alarm (Red): Flashes if in alarm; solid when alarm is silenced • Supervisory (Yellow): Flashes if a supervisory condition exists; solid when supervisory is silenced • System Trouble (Yellow): Flashes if a trouble condition exists; solid when trouble is silenced • System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared • System Power (Green): Flashes for AC failure; solid when power systems are normal USER INTERFACE The 6700 built-in 4 x 20 annunciator with 80 character LCD display and large easy-to-use tactile touch pad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1,000 events for viewing from the built- in or remote annunciator. System operations can be initiated with a mechanical firefighter's key or a valid 4 -to 7-digit operator's code. Page 2 of 4 -351607:B 9/26/2018 PROGRAMMING The 6700 system offers several options to simplify and speed-up programming. JumpStart® auto programming minimizes programming required to start a new system. The built-in keypad, or the 6860, 5860 or 6855 remote annunciators give you on-site access to current system programming. Programming can also be accomplished using the Windows®-based Honeywell Fire Software Suite (HFSS) program. SOFTWARE TOOLS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows® software system configuration tool to create a detailed Bill of Material CBOM) and battery ca Leu lations. HFSS: Honeywell Fire Software Suite provides communication and panel programming, detector status, event history and additional data. Requires a PC running Microsoft® Windows®. ADDITIONAL INFORMATION Twisted-unshielded pair wire is recommended. The 6700 also has 13 preset notification cadence patterns (including ANSI 3.41). AGENCY LISTINGS AND APPROVALS N PFA 13, N FPA 15, N FPA 16, N FPA 70, NFPA 72: Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterflow, sprinkler supervisory CDACT non-coded) signaling services • UL Listed: S2766 • CSFM 7165-0559:0501 • FDNY COA# 6250 ORDERING INFORMATION 6700: Addressable Fire Alarm Control Panel. (Red cabinet) COMPATIBLE ANNUNCIATORS 6860: 4x40 LCD remote fire annunciator (4 lines and up to 160 characters) per system; four programmable buttons 5860: 4x20 LCD remote fire annunciator. 5860 is gray; 5860R is red 6855: 4x20 LCD remote fire annunciator 5865-3 or 5865-4: LED annunciators can display up to 30 LEDs (15 red and 15 yellow). The 5865-4 has key switches for silence and reset, and a system trouble LED. 5880: The 5880 LED/ 10 module has 40 programmable LED outputs and eight supervised dry contact inputs which are useful for custom applications. You can use up to eight 5880 modules on one control panel for maximum flexibility. Its compact size allows mounting inside the annunciator, or in an accessory cabinet. 6700 COMPATIBLE DEVICES AND ACCESSORIES See the data sheets listed below for a complete listing of the SK, SD or SWIFT devices. 53623: SK Devices Data Sheet 53624: SD Devices Data Sheet 350614, 350616 & 350618: SWIFT wireless devices For a complete and current listing of compatible devices and accessories, visit www.silentknight.com Important: You cannot mix SK and SD devices in the same fire alarm system. SK COMPATIBLE ADDRESSABLE DEVICES SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135°F fixed temperature SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T: Reflected beam smoke detector with test feature SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended air speed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-W: Fixed thermal detector (135°F), white SK-HEAT-ROR: Fixed rate of rise detector (135°F) SK-HEAT-ROR-W: Fixed rate of rise detector (135°F), white SK-HEAT-HT: Fixed high temperature thermal detector (190°F) SK-HEAT-HT-W: Fixed high temperature thermal detector (190°F), white SK-ISO: Fault isolator module SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10: 10 input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-W: Photoelectric smoke detector, white SK-PHOTO-T: Photoelectric smoke detector with thermal (135°F fixed temperature) SK-PHOTO-T-W: Photoelectric smoke detector with thermal (135°F fixed temperature), white SK-PHOTOR: Photoelectric detector with remote test capability SK-PHOTO-R-W: Photoelectric detector with remote test capability, white SK-PULL-SA: Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2: Addressable Dual relay/ monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module 8300-6(-IV): 6" base for SK-W Series 8210LP: 6" mounting base 8501(-BL,-IV,-WHITE): 4"flangeless base 8501: 4" Flangeless mounting base 8200S(-IV,-WH): Intelligent sounder base 8200S: Intelligent sounder base 8200S-LF(-IV,-WH): Low-Frequency intelligent sounder base 8200S-LF: Low-frequency intelligent sounder base 8224RB(-IV,-WH): Relay base 8224RB: Relay base 82248I(-IV,-WH): Isolator base 822481: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES SD505-6AB: Addressable 6" base SD505-6I8: Addressable 6" short circuit isolator base SD505-6RB: Addressable 6" relay base SD505-6SB: Addressable 6" sounder base SD500-AIM: Addressable input module (switch input) SD500-ANM: Addressable notification module SD500-ARM: Addressable relay module SD505-DTS-K: Remote test switch and LED indicator for the SD505-DUCTR SD505-DUCT: Addressable Duct Smoke Detector. SD505-DUCTR: Addressable Duct Detector housing with relay base. SD505-HEAT: Absolute temperature heat detector. Trip point range from 135°F-150°F (0°C-37°C). SD500-LIM: Addressable Line isolator module SD500-MIM: Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA: Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module AUDIBLEIVISIBLE DEVICES These AV devices are all 2-wire. Color: "R" indicates red; "W" denotes white. For a complete listing of Silent Knight AV devices go to www.silentknight.com. CHSRUCHSWL: Wall chime/strobe CHSCRUCHSCWL: Ceiling chime/strobe CHRUCHWL: Wall chime HRUHWL: Wall horn P2RUP2WL: Wall horn/strobe PC2RUPC2WL: Ceiling horn/strobe SRUSWL: Wall strobe SCRUSCWL: Ceiling strobe SPSCRUSPSCWL: Ceiling speaker/strobe SPSRUSPSWL: Wall speaker/strobe SPRUSPWL: Wall speaker SPCRUSPCWL: Ceiling speaker SWIFT WIRELESS DEVICES SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. WSK-WGI: Wireless Gateway WSK-PHOTO: Wireless Photoelectric smoke detector VVSK-PHOTO-T: Wireless Multi-criteria photoelectric smoke detector with thermal detection (135°F fixed temperature) and 8510W 4" base VVSK-HEAT: Wireless Heat, (135°F fixed temperature) and 8510W 4" base WSK-HEAT-ROR: Wireless heat, ROR (135°F fixed temperature) and 8510W 4" base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module W-USB: SWIFT Tools USB transceiver used for communication with SWIFT devices SBUS ACCESSORIES 5496: A 6 amp notification power expander with four power-limited notification appliance circuit outputs. 5883: Relay interface. Provides 10 Form C relays. 5824: Serial/Parallel printer interface module for printer connection. 5895XL: Power supply with six Flexput® circuits, and two Form C relays. Max. 16 per system. 5815RMK: Remote mounting kit. Dimensions 10 3/8"W x 10-3/16"H x 3"0 COMMUNICATION OPTIONS CELL-CAB-SK: Cellular communicator, metal enclosure with lock/key* CELL-MOD: Cellular communicator, plastic enclosure* *Sole path, powered by panel. IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-IP-2: Remote reporting via the Internet. Requires a VisorAlarm® receiver at the central station MISC. ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications link for the 6700 SK-NIC-KIT: Installation Accessory Kit SK-FML: Fiber-Optic Multi Mode, transmitter and receiver SK-FSL: Fiber-Optic Single Mode RBB: Remote battery box accessory cabinet for batteries that are too large to fit in the FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406mm W x 254mm H x 152mm D). SK-SCK: Seismic Compliance Kit used to securely fasten batteries to the fire panel. Page 3 of 4 -351607:B 9/26/2018 6700 Technical Specifications PHYSICAL Overall Dimensions: 12.11· w x 15.12" H x 3.33" D Weight: 15 lbs. Color: Red ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 0 to 93% relative humidity (non- condensing) ELECTRICAL 6700 Primary AC: 120VAC@60 Hz, 1.5ATotal Accessory Load: 2.5A@ 27.4 VDC power-limited Standby Current: 165mA Alarm Current: 310mA Battery Charging Capacity: 7 to 35AH Battery Size: 7AH max. allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. Honeywell Silent Knight 12 Clintonville Road Northford, CT 064 72 800-328-0103 www.silentknight.com NOTIFICATION APPLIANCE CIRCUITS (NACs) Two programmable circuits which can be programmed individually as: NACs: 2.5A@ 27.4VDC per circuit, power-limited (with a panel maximum current of 2.5A) Auxiliary Power Circuits: 2.5A@ 27.4VDC per circuit, power-limited Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for the SLC WIRING: See the product manual for wiring details 351607 I B I 09/18 © 2018 Honeywell International Inc. Flexput•, Honeywell•, JumpStart•. Silent Knight•, SWIFT•, and System Sensor• are registered trademarks of Honeywell International Inc. Hochiki• is a registered trademark of Hochiki Corporation. Microsoft• and Windows• are registered trademarks of Microsoft Corporation. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. Honeywel El LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7165-0559: 0501 7165 --FIRE ALARM CONTROL UNIT (COMMERCIAL) SILENT KNIGHT SECURITYOne Fir. -ite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 4 -544 Fax (203) 484-7309 Email: megan.sisson@hon Page 1 of 2 Silent Knight Model 6700, Fire Alarm Control Unit, automatic, manual, local, remote station (PPU), central station (PPU), releasing (water deluge only). *The CELL-MOD and CELL-CAB-SK have the option to be configured by a compatible control unit for the following pathways: Cellular only without a backup path, primary Cellular communication path, or secondary Cellular communication path. Model 6700 System Components: 5860 Remote Annunciator 6855 Remote Annunciator 6860 Remote Annunciator 5496 NAC Expander 5880 LED 1/0 Module 5865-3 Remote LED Annunciator 5865-4 Remote LED Annunciator 5883 Relay Interface 5824 Serial/Paralell Printer Interface Module 5895XL Power Supply SK-NIC Network lnerface Card SK-NIC-KIT Network Interface Card in Cabinet SK-FML Mulit Mode Fiber Card SK-FSL Single Mode Fiber Card CELL-MOD Celullar Communicator in Plastic Enclosure CELL-CAB-SK Cellular Communicator in Metal Enclosure with Lock & Key RBB Remote Battery Box (16''WX10"HX6"D) SK-SCK Seismic Complaince Kit Primary Operating Power Supply: 120VAC, 60HZ, 1.5A Secondary Operating Power Supply: 24VDC, 3.1A, 35Ah In accordance with listee's printed installation instructions, applicable codes and ordinances *Rev 10-02-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 Listing No. 7165-0559:0501 Page 2 of 2 and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a commercial fire alarm control unit for use with separately listed initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. *Rev 10-02-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 . Mn DMP.COM O O e O 0 G @DMPALARMS •-iii' / CellCom LTE Alarm Communicators ► CellCom-LTE-V and CellComF-LTE-V enable basic remote panel control via Virtual Keypad™ app ► Provides end user alerts of arming/disarming, alarm, and other events ► Add Z-Wave control of lights, locks, and thermostats with CellComZ-LTE-V ► Fully supervised universal alarm communication over LTE ► Program your own account number to easily work around locked panels ► External SMA antenna ► Use Contact ID dialer ► Armed/disarmed status LED capture, four input zones or bell monitoring ► Private labeling available on the rubber logo insert ► Wiring for Ademco ECP Bus ► Two output terminals with ► Communicates with multiple output options DMP SCS-lR and SCS-VR Receivers WORKS WITH MOST PANELS If the existing panel supports Contact ID, then it's a candidate for upgrading with CellCom-LTE-V, CellComZ-LTE-V, or CellComF-LTE-V. There are no issues with lockout codes. Simply add the CellCom-LTE-V unit to the existing installation and program in your own account number. AVAILABLE BURGLARY COMMUNICATION The CellCom-LTE-V provides control of basic panel security functions and video. The CellComZ-LTE-V adds the ability to remotely interact with Z-Wave devices, enabling a variety of home automation features including control of lights, door locks, thermostats, and more. FIRE COMMUNICATION The CellComF-LTE-V offers cellular fire communication on any fire control panel via Contact ID captures or zone inputs. Meets NFPA 72 Standard for Single Communication Technology. MOBILE SYSTEM CONTROL With CellComLTE communicators, you can easily update your customers' older residential and commercial systems to the latest cellular communication links. With cellular in place, end users can remotely access their panels via the Virtual Keypad app. This makes it possible to use their mobile device not only to control basic arm/disarm functions and receive alerts, but also to control Z-Wave home automation devices. ENABLE VIDEO ON THE APP With the CellCom-LTE-V communicators, you can easily add up to six video cameras. Via the Virtual Keypad app, end users can remotely view their premises to cancel or verify an alarm or simply check in on children or senior adults. Users can also capture still or video images. FULLY SUPERVISED COMMUNICATION CellCom-LTE-V allows alarm messages to be communicated to an SCS-lR or SCS-VR Receiver over the Verizon LTE network. Sending alarm communication for burglary control panels over the LTE network provides higher speeds. FIELD PANEL UPDATES The Model 400 USB Flash Module allows you to easily field update firmware for panels that would otherwise require the use of a computer and a Model 399 Programming Harness. SYSTEM PROGRAMMING Specifications Dimensions 5.5" W x 3.75" H x 1" D Color White Open-Collector Outputs 2 Zones CellCom-LTE-V 4 System programming over cell via Primary Power 12VDC Virtual link™ includes zone information Current Draw and monitoring center communications. Alarm 99mA 51mA MULTIPLE CONNECTION OPTIONS ~ 1 standby CellCom-LTE-V communicators can ~Cell(omf-LTE-V be attached to the existing panel in a variety of ways. It can capture Contact ID messages from the dialer or connect the four input zones from outputs on the panel. Or it can sense the output of the bell of an existing alarm and communicate the appropriate message to the central station. FOUR ZONES Each of the CellCom-LTE-V models provide four zones for connection to burglary control panel outputs. Zone 4 is intended for connection to the control panel bell output. OUTPUTS Use outputs to connect to an arming zone of an existing panel for control of that panel via the app. EASY UPGRADE FOR DIALER-ONLY PANELS Older, dial-up panels have new life with the addition of cellular communication. Earn customer loyalty by extending the life of their existing panels and build satisfaction with the purchase decision. BUILD CUSTOMER LOYALTY Avoid the possibility of customers seeking mobile intrusion alarm features from a competitor by enabling those features on their existing panel with a minimal additional cost. They are less likely to switch systems and cancel their contract. When the time does come to replace the panel, they are more likely to rely on you. DMP's Virtual Keypad app can be branded with your organization's logo and contact information to provide a daily reminder of your services. Primary Power Current Draw at 12VDC 12-24VDC Alarm 99mA Standby 51 mA Current Draw at 24VDC Alarm Standby CellComl-LTE-V 81mA 30mA Primary Power 12VDC Current Draw Alarm 109mA Standby 64 mA Ordering Information CellCom-LTE-V Universal Alarm Communicator CellComF-LTE-V Universal Fire Alarm Communicator CellComZ-LTE-V Universal Alarm Communicator with Z-Wave Certifications California State Fire Marshal (CSFM) Underwriters Laboratory (UL) Listed ANSI/UL 1610 Central Station Burglar (Cellular) ANSI/UL 1023 Household Burglar ANSI/UL 985 Household Fire Warning (CID Capture) ANSI/UL 864 Fire Protective Signaling Systems Cellular FCC Part 15: MIVCNN0301 CellComLTE FCC Part 1510: CCKPC0163 IC: 5251A-PC0163 800-641-4282 I DMP.com 2500 N. Partnership Blvd, Springfield, MO 65803 Designed, Engineered & Manufactured in Springfield, MO using U.S. & global components © 2018 Digital Monitoring Products, Inc. I LT-ITT4 I 18345 LISTING No. CATEGORY: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-1157:0136 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Page 1 of 1 LISTEE: Digital Monitoring Products, lnc.2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Amy Bade (417) 831-9362 Fax (417) 447-9698 ~ Email: abade@dmp.com DESIGN: ~ Models CellComSLC, CellComSLCZ, CellComSLCF, CellCom-L TE-V, CellComZ-L TE-V, RATING: INSTALLATION: MARKING: APPROVAL: CellComF-L TE-V, iComSLF, iCOMSL, iComSLZ, DualComNF-L, *CellComSF, and *CellComDF Communicators. Refer to listee's data sheet for additional detailed product description and operational considerations and listee's installation instructions for details. 12 voe or 24 voe In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as alarm communicators for use with separately listed fire and burglary alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. Burglary and other non-fire functions were not examined. *Revision 02-26-20 VWW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 SPECIFICATIONS Nominal Voltage (V) Nominal Capacity 20 hour rate ( 0.36A to 10.50V) 10 hour rate ( 0.72A to 10.50V) 5 hour rate ( 1.22A to 10.20V) 1 C ( 7.2A to 9.60V) 3C ( 21.6A to 9.60V) Weight Internal Resistance (at 1 KHz) Maximum Discharge Current for 30 seconds: Maximum Discharge Current for 5 seconds: Operating Temperature Range Charge Discharge Storage 12V 7.2Ah 6.84Ah 6.12Ah 3.24Ah 2.52Ah Approx. 5.39Lbs. (2.45kg) 22mQ 144A 288A 0°c (32°F) to 40°C (104°F) -15°C ( 5°F ) to 50°C (122°F ) -15°C ( 5°F) to 40°C (104°F) Charge Retention (shelf life) at 20°c ( 68°F) 1 month 92% 90% 80% 3 months 6 months Charging Methods at 20°c ( 68°F) Cycle Use : Charging Voltage 14.4 to 15.0V Standby Use : Life expectancy : Cycle Use: Standby Use : Maximum Charging Current : 2.16A Float Charging Voltage 13.50 to 13.80V 100% depth of discharge 200 cycles 80% depth of discharge 225 cycles 50% depth of discharge 500 cycles 3-5 years Case Material : ABS (Option : 94-HB & 94V-0 Flame Retardant Case Material) Terminal: F1 or F2 MK Battery 1631 South Sinclair Street• Anaheim, California 92806 Toll Free: 800-372-9253 • Fax: 714-937-0818 • E-mail: sales@mkbattery.com ES7-12 Maintenance-Free Rechargeable Sealed Lead-Acid Battery DIMENSIONS mm(inch) F1 F2 (FASTON TAB NO. 117) ('FASTON TAB NO. 2118) 00 I 65±1(2.56:ID.04) 151±1 5.94:!D.04 I"\ I"\ Discharge Time VS. Discharge Current (20°C) 1 z 4 e 110 20 40 eo z 4 e 110 20 I-mlnutH hours --+ i Discharge Time . INTELLIKNIGHT ACCESSORY ® SILENT KNIGHT by Honeywell SK-Pull-SA and SK-Pull-DA~ Intelligent Pull Stations The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's lntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The lntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the lntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Pull-SA is a single action pull station requiring only one motion to activate the station. The SK-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight lntelliknight series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition • Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1 .3[13]) • Meets ADA requirement for 5 lbs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® • Reliable analog communications for trouble-free operation • Braille text on station handle • Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled • Rotary address switches for fast installation • UL Listed, including UL 38, Standard of Manually Actuated Signaling System SK-Pull-SA SK-Pull-DA ~ Compatibility The SK-Pull-SA and SK-Pull-DA are compatible with the following lntelliKnight FACP's: 5600 5700 5808 5820XL INTELLIKNIGHT ACCESSORY Model SK-Pull-DA and SK-Pull-SA Engineering Specifications The contractor shall furnish and install where indicated on the plans, Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. • ac OUT Compatible FACP Class A ClanB I C1assA Wlrtng: = I Class B Wlrtng: -- 0 0 0 0 ~ 0 0 0 0 Specifications Physical Height: 5.5" (14 cm) Width: 4" (10.2 cm) Depth: 5.4 oz. (3.7 cm) -- Wiring SK.Pull-SA & SK-Pull-DA Pull Stations Electrical Operating Voltage: 15--32 voe Average Operating Current (LED flashing): 300 µA Wire Gauge: Up to 12 AWG (3.1 mm2) Environmental Housing Material: LEXAN polycarbonate resin Bi-Colored LED: Operating Temperature 32° -120°F (0°C -49°C) Humidity: 10% -93% non-condensing Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (N/O) switch which closes upon activation of the pull station Accessories BG-TR SB-1/O Optional trim ring. Surface backbox ~ SILENT ~KNIGHT by Honeywell This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com MADE IN AMERICA FORM# 350135 Rev A © 2009 Honeywell International Inc. LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7150-0559:0161 Page 1 of 1 7150 --FIRE ALARM PULL BOXES SILENT KNIGHT SECURITYOne Fire-Lite ace, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 x (203) 484-7309 Email: megan.sisson@honeywell.co Models SK-PULL-SA and SK-PULL-DA single/dual action fire alarm pull boxes. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, rating, and UL label. Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. 7150-0028:0199 04-16-09 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 INTELLIKNIGHT ACCESSORY -~➔SK-Photo and SK-Photo-T Intelligent Photoelectric Smoke Sensors The SK-Photo is a photoelectric smoke detector and the SK-Photo-T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight lntelliKnight Fire Alarm Control Panels (FACPs). For more information about the lntelliKnight system, or to locate your nearest source, please call 800-328-0103 or in Connecticut, call (203) 484-7161. Description SK-Photo and SK-Photo-T are plug-in type smoke sensors that combine a photoelectric sensing chamber with addressable analog communications. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. SK-Photo and SK-Photo-T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the SK-Photo-T, dual electronic thermistors add 135°F (57°C) thermal technology to maximize detection. Features • Sleek, low-profile design • Base included • Reliable analog communications for trouble-free operation • Age resistant polymer housing • Dual electronic thermistor design on the SK-Photo-T • Superior EMI resistance for reliability • Simple field cleaning for code compliance • Variety of mounting options to meet any application • Dual LED indicators for 360° visibility • Detector transmits signal to indicate maintenance is required • Optional remote LED annunciator (System Sensor® PN RA 1002) • Plug-in mounting provides ease of installation • Tamper-proof feature available on mounting bases • Listed for use in duct applications • Rotary address switches for fast installation • UL Listed • FM Approved Specifications Physical Height: 2.0" (5.0 cm) Diameter: 4.1" (10.4 cm) Shipping Weight: 5.2 oz. (147 g) Electrical Operating Voltage: 15--32 voe Standby Current: 300 µA @ 24 VDC Maximum Alarm Current: 6.5 mA @ 24 VDC max (with LED on) Environmental Operating Temperature SK-Photo: 32° -120°F (0°C -49°C) SK-Photo-T: 32° -100°F (0°C -38°C) Humidity: 10% -93% non-condensing Other Ratings SK-Photo-T Thermal: Fixed temperature set point 135°F (57°C) Velocity: 0 -4000 fpm (0 -20 m/sec) SK-Photo Insect Screen Hole Size: 0.016" (0.41 mm) nominal SK-Photo (Base included) Compatibility The SK-Photo and SK-Photo-T are compatible with the following lntelliKnight FACPs: 5700 5808 5820XL SK-Photo and SK-Photo-T are compatible with the following detector bases: 8210LP 8501 8501BHT-2 8224RB 822481 8501BH-2 (included) 6" base 2 wire base Temporal base Relay base Isolator base Sounder base ~ SILE ~KNIGHT byHoneywel INTELLIKNIGHT ACCESSORY I Model SK-Photo and SK-Photo-T Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shall be UL listed and compatible with Silent Knight's lntelliKnight fire control panels. The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lock base part number B210LP (included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. G'a,_11J11PAOII _______ ......,.. lloiiiiiii ________ ___. ..., ____ I ~SILENT ~ G bJHor-,wel I ' -~- IK.-...o.i.tar~.._. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com MADE IN AMERICA FORM# 350118 Rev A, © 2009 Honeywell International Inc. LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7272-0559:0149 7272 --SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com Page 1 of 1 Models IDP-PHOTO, IDP-PHOTOR*, IDP-PHOTO-T, !DP-ACCLIMATE, SK-PHOTO, SK-PHOTOR*, SK-PHOTO-T and SK-ACCLIMATE photoelectric type smoke detectors. Model IDP-PHOTO-T employs a 1350F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. 24VDC In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Listee's name, product number, electrical rating and UL label. Listed as photoelectric type smoke detector for use with listee's separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 0-4000 FPM. Models IDP-PHOTO and IDP-PHOTOR are approved for installations inside System sensor duct housing DNR (OSFM Listing No. 3242-1653:209) and DNRW (OSFM Listing No. 3242-1653:210)*. Models SK-PHOTO and SK-PHOTOR are approved for installations inside Silent Knight SK-DUCT (OSFM Listing No. 3242-0559:162) and System Sensor DNRW (OSFM Listing No. 3242-1653:210)* The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. 7272-0028:0206 *Rev. 02-01-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 ® SILENT KNIGHT by Honeywell INTELLIKNIGHT ACCESSORY ~ SK-Minimon Intelligent Mini Monitor Module The SK-Minimon addressable mini monitor modules for use with Silent Knight lntelliKnight fire alarm control panels (FACP). The SK-Minimon is designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. For more information about the lntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description The SK-Minimon is an addressable monitor modules for use with the lntelliKnight fire alarm control panels (FACPs ). The SK-Minimon acts as an interface to contact devices, such as waterflow switches and pull stations. The SK-Minimon supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions The SK-Minimon can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. Features • Single contact monitor • SK-Minimon support for Class B (Style B) contact monitor wiring • Small and lightweight size allows for flexible mounting options • Rotary address switches for fast installation • UL listed Specifications Electrical Standby Current: 400 uA max @ 24 VDC with comm. Voltage Range: 15 -32 VDC SK-Minimon Compatibility The SK-Minimon is compatible with the following lntelliKnight Systems: 5820XL 5808 End of Line Resistance: 4 7 k Ohms 5700 Physical Dimensions: 2.75" W X 1.3" H X 0.5" D Weight: 1.2 oz (37 g) Environmental Operating Temperature: 32°F -120°F (0°C -49°C) Humidity: 10% -93% non-condensing 5600 (Rev 2.0 or higher) SK-FFT Approvals UL approved CSFM FM Approved INTELLIKNIGHT ACCESSORY SK-Minimon Intelligent Monitor Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable monitor modules Silent Knight SK-Minimon. The modules shall be UL listed and compatible with Silent Knight's lntelliKnight FACPs. The device shall be capable of Styles A and B supervised wiring to the load device. The SK-Minimon shall be installed inside a single gang junction box directly behind the monitored unit. Compatible FACP • SILENT KNIGHT by Honeywell ADDRESS LOOP D 01 2 3 4 5 8976 ONES Wiring the SK-Minimon This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203)484-7118. www.silentknight.com Other Devices MADE IN AMERICA FORM# 350133 Rev C © 2011 Honeywell International Inc LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-0559:0155 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Page 1 of 1 SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 ✓ Email: megan.sisson@honeywell.com Models IDP-Relay-6, SK-Relay-6, relay module, IDP-Control-6, SK -Control-6, supervisi control module, IDP-Monitor-10, SK-Mon-10, input monitor module, IDP-Zone-6, SK-e-6 six zone interface module, !DP-Monitor, IDP-Minimon, IDP-Zone, SK-Monitor, SK-Minimon, SK-Zone monitor modules, !DP-Control, IDP-Relay, SK-Control, SK-Relay, control modules, IDP-Monitor-2, SK-Monitor-2, dual monitor modules.and *IDP-RELAYMON-2, *SK-RE LA YMON-2 with 2 input/2 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. 16-33 VDC Primary In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Listee's name, product number and UL label. Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. If an external power supply is used for Model SK-Zone-6 and IDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. 7300-0028:0219 *Rev. 10-25-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 Fire/Life Safety SmartWire™ UL Listed and Rated Type CMR or FPLR Multi-Conductor Non-Shielded Non-Plenum Fire Alarm CSFM# 7161-1727:0100 D162F ~onductor Non-Shielded Non-Plenum Fire Alarm scriptlon onductor Description Agencies Approvals: 16 AWG 2 Conductor Bare p,pper, Non-Shielded Non- m FIN Alarm, UL C(UL) RorFPLR UL CONTROL • DEVICE/ 123456 LC(UL)CMR ROHS MADE NEC Article 800, 760; UL C(UL) CMR or FPLR UL, RoHS Compliant, Made in the USA UL Listed and Rated Type TC, PLTC, FPL OR NPLF Multi-Conductor Non-Shielded Non-Plenum Cable CSFM# 7161-1727:0100 H2+162 ~r Non-Shielded Non-Plenum Quad Rated Fire Alarm scription Agencies Approvals: 6 AWG 2 Conductor Bare ~, Non-Shielded Non- m Quad Rated Fire UL Type TC, PLTI:, orNPLF C with Nylon C .040• Nom. ¥ CITY WIRE A B C D 23456789 (UL) TYPE TC 600V Y 7SC WET "DIR SUN RES• PLTC, FPL MADE IN THE USA RE WARRIOR®" SOhms/Mft. 20 C to 105 C / 600 olt 2 Lbs/Mft. UL Standard 1277, UL 1424 Power limited fire alarm cables, UL 1425 Non-power limited fire alarm cables, UL 13 power limited circuit cables, NEC Articles 340, 725, 760, Made in the USA ®