HomeMy WebLinkAbout5796 ARMADA DR; 325; FPC2021-0176; PermitPERMIT REPORT
Fire Permit
Print Date: 01/12/2022
Job Address:
Permit Type:
Parcel#:
Valuation:
Occupancy Group:
#of Dwelling Units:
Bedrooms:
Bathrooms:
Project Title:
5796 ARMADA DR, # 325, CARLSBAD, CA 92008-4693
FIRE-Construction Commercial Work Class:
2111000400 Track#:
$139,669.53 Lot#:
Project#:
Plan#:
Construction Type:
Orig. Plan Check#:
Plan Check#:
Fire Alarm
(city of
Carlsbad
Permit No: FPC2021-0176
Status: Closed -Finaled
Applied: 09/14/2021
Issued: 10/27/2021
Finaled Close Out: 01/12/2022
Inspector:
Final Inspection:
Description: NINTH CIRCUIT COURT JUDGES QUARTERS -EXPAND EXISTING FIRE ALARM SYSTEM (3 NOTIFICATION DEVICES)
Applicant:
LOW VOLTAGE INTEGRATED SYSTEMS
KYLE ARGUIJO
1090 JOSHUA WAY, #STEA
VISTA, CA 92081-7800
(760) 598-4110
FEE
FIRE Tl Fire Alarm System
Total Fees: $682.00
Fire Department
Total Payments To Date: $682.00
FPContractor:
LOW VOLTAGE FIRE INC
1090 JOSHUA WAY, # UNIT A
VISTA, CA 92081-7800
(760) 598-4110
Balance Due:
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov
AMOUNT
$682.00
$0.00
Page 1 of 1
FIRE ALARM SYSTEM
SUBMITTAL
•....._...,.....
Lc.>w~c.>l,-C11ge
integra-ted sys-tems
FIRE ALARM• SOUND e DATA e MEDIA• SECURITY• CCTV • ACCESS CONTROL
SUBMITTAL
JUDGES QUARTERS STE 325
5796 ARMADA DR.
CARLSBAD CA 92008
LOW VOLTAGE INTEGRATED SYSTEMS, INC.
1090 Joshua Way Ste A
VISTA, CA 92081
(760) 598-4110 Phone
(760) 598-4107 Fax
info@sdlvis.com
License: ClO, Cl6 # 791832
PHONE: (760) 598-4110
FAX: (760) 598-4107
LowVo/,-~ge
I ntegrated .5y$tems
MATERIAL LIST
PART
PC2WL
SCWL
P2WL
DES<;_RIPTIQN MANUFACTURER
HORN/STROBE@CEILING SYSTEM SENSOR
STROBE@CEILING SYSTEM SENSOR
HORN/STROBE @ WALL SYSTEM SENSOR
Low Voltage Integrated Systems, Inc.
1090 Joshua Way, Ste A. Vista, California 92081
FIRE• SECURITY• CCTV• ACCESS CONTROL • SOUND• MEDIA
LICENSE NO. C10, C16 #791832
email: info @ sdlvis.com
Indoor Selectable-
Output Strobes and
Horn Strobes for
Ceiling Applications
System Sensor L -Series audible visible notification
products are rich with features guaranteed to cut
installation times and maximize profits with lower
current draw and modern aesthetics.
Features
• Plug-in design with minimal intrusion into the back box
• Tamper-resistant construction
• Automatic selection of 12-or 24-volt operation
at 15 and 30 candela
• Field-selectable candela settings on ceiling units:
15, 30, 75, 95,115,150, and 177
• Horn rated at 88+ dBA at 16 volts
• Rotary switch for horn tone and two volume selections
• Universal mounting plate for ceiling units
• Mounting plate shorting spring feature checks wiring continuity
before device installation
• Electrically Compatible with legacy SpectrAlert and SpectrAlert
Advance devices
• Compatible with MDL3 sync module
• Listed for ceiling mounting only
Agency Listings
SIGNALING
@
LISTED
S5512
$401 1
<8> APPROVED
FM approved except
for ALERT models
3057383
I
7125-1653:0504
7135-1653:0503
The System Sensor L-Series offers the most versatile and
easy-to-use line of horns, strobes, and horn strobes in the industry
with lower current draws and modern aesthetics. With white and red
plastic housings, wall and ceiling mounting options, System Sensor
L-Series can meet virtually any application requirement.
The entire L-Series product line of ceiling-mount strobes and horn
strobes include a variety of features that increase their application
versatility while simplifying installation. All devices feature a plug-in
design with minimal intrusion into the back box, making installations
fast and foolproof while virtually eliminating costly and time-
consuming ground faults.
To further simplify installation, the L-Series utilizes a universal
mounting plate so installers can mount them to a wide array of back
boxes. With an onboard shorting spring, installers can test wiring
continuity before the device is installed.
Installers can also easily adapt devices to a suit a wide range of
application requirements using field-selectable candela settings,
automatic selection of 12-or 24-volt operation, and a rotary switch
for horn tones with two volume selections.
AVDS868-02 • 12/01/2017 • Page 3
L-Series Specifications
Architect/Engineer Specifications
General
L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 1½-inch back box, 4-inch octagon back box, or double-
gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used
for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series
products, when used with the Sync•Circuit"' Module accessory, shall be powered from a non-coded notification appliance circuit output
and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs
shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor
L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.
Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75 , 95, 115, 150, and 177.
Strobe
The strobe shall be a System Sensor L-Series Model ___ listed to UL 1971 and shall be approved for fire protective service. The strobe
shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible
signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and
associated lens/ref lee tor system.
Horn Strobe Combination
The horn strobe shall be a System Sensor L-Series Model ___ listed to UL 1971 and UL 464 and shall be approved for fire protective
service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act
requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist
of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a
temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe
models shall operate on a coded or non-coded power supply.
Synchronization Module
The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module
shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns
on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also
control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more
synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply.
Physical/Electrical Specifications
Standard Operating Temperature
Humidity Range
Strobe Flash Rate
Nominal Voltage
Operating Voltage Range2
Operating Voltage Range (MDL3)
Input Terminal Wire Gauge
Ceiling-Mount Dimensions (including lens)
Ceiling-Mount Surface Mount Back Box Skirt Dimensions
(SBBCRL, SBBCWL)
Notes:
32°F to 120°F (0°C to 49°C)
10 to 93% non-condensing
1 flash per second
Regulated 12 voe or regulated 24 DC/FWR1
8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal)
8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal)
12to 18AWG
6.8" diameter x 2.5" high (173 mm diameter x 64 mm high)
6.9" diameter x 3.4" high (175 mm diameter x 86 mm high)
1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs.
2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 ed.
AVDS868-02 • 12/01/2017 • Page 2
UL Current Draw Data
UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS)
8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33Volts
Candela DC DC FWR Sound Pattern dB DC DC FWR
Candela I;~ I 87 I:; I 60 Temporal High 39 44 54
Range 153 86 Temporal Low 28 32 54
75 N/A 111 142 Non-Temporal High 43 47 54
95 N/A 134 164 Non-Temporal Low 29 32 54
115 N/A 158 191 3.1 KHz Temporal High 39 41 54
150 N/A 189 228 3.1 KHz Temporal Low 29 32 54
177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54
3.1 KHz Non-Temporal Low 28 29 54
Coded High 43 47 54
3.1 KHz Coded High 42 43 54
UL Max. Current Draw {mA RMS), Ceiling Horn Strobe, Candela Range (15-1n cd)
8-17.5 Volts 16-33Volts
DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd
Temporal High 103 167 71 90 143 165 187 217 254
Temporal Low 96 165 54 71 137 161 185 211 249
Non-Temporal High 106 173 71 90 141 165 187 230 273
Non-Temportal Low 95 166 54 71 124 161 170 216 258
3.1 K Temporal High 111 164 69 94 147 163 184 229 257
3.1 K Temporal Low 103 163 54 88 143 155 185 212 252
3.1 K Non-Temporal High 111 172 69 94 144 164 202 229 271
3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259
16-33 Volts
FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd
Temporal High 107 135 179 198 223 254 286
Temporal Low 78 101 151 172 199 229 262
Non-Temporal High 107 135 179 198 223 254 286
Non-Temportal Low 78 101 151 172 199 229 262
3.1 K Temporal High 108 135 179 200 225 255 289
3.1 K Temporal Low 79 101 150 171 196 229 260
3.1 K Non-Temporal High 108 135 179 200 225 255 289
3.1 K Non-Temporal Low 79 101 150 171 196 229 260
Horn Strobe Tones and Sound Output Data
Hom Strobe Output (dBA)
8-17.5 16-33
Switch Volts Volts
Position Sound Pattern dB DC DC FWR
1 Temporal High 84 89 89
2 Temporal Low 75 83 83
3 Non-Temporal High 85 90 90
4 Non-Temporal Low 76 84 84
5 3.1 KHz Temporal High 83 88 88
6 3.1 KHz Temporal Low 76 82 82
7 3.1 KHz Non-Temporal High 84 89 89
8 3.1 KHz Non-Temporal Low 77 83 83
AVDS868-02 • 12/01/2017 • Page 3
L-Series Dimensions
6.83' diam.
(173mm)
2.47" (62.7 mm) --------i
1.37" (34.8 mm) -1-------,-..-;i...i
Ceiling-Mount Horn Strobes
2-Wire Ceiling Mount Horn Strobes
with Ceiling Surface Mount Back Box
L-Series Ordering Information
Model Description
Ceiling Horn Strobes
PC2RL 2-Wire, Horn Strobe, Red
PC2WL 2-Wire, Horn Strobe, White
PC4RL 4-Wire, Horn Strobe, Red
PC4WL 4-Wire, Horn Strobe, White
A0545-00
For a ceiling-listed horn-only device, see AVDS865 "Indoor Selectable-
Output Horns, Strobes, and Horn Strobes for Wall Applications".
6.92' diam.
(175.77 mm) r-25' 7 I (64mm)
1
0
0 '
Ceiling Surface Mount Back Box
4-Wire Ceiling Mount Horn Strobes
with Ceiling Surface Mount Back Box
Model Description
Ceiling Strobes
SCRL Strobe, Red
SCWL Strobe, White
SCWL-CLR-ALERT Strobe, White, ALERT
Accessories
TRC-2 Universal Ceiling Trim Ring Red
TRC-2W Universal Ceiling Trim Ring White
SBBCRL Ceiling Surface Mount Back Box, Red
SBBCWL Ceiling Surface Mount Back Box, White
A0546-00
3825 Ohio Avenue• St. Charles, IL 60174
Phone: 800-SENSOR2 • Fax: 630-377-6495
©2017 System Sensor.
Product specifications subject to change withou notice. Visit systemsensor.com
for current product information, including the latest version of this data sheet.
AVDS868-02 • 12/01/2017
LISTING No.
CATEGORY:
LISTEE:
DESIGN:
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
7135-1653:0503
7135 --AUDIBLE DEVICES
Page 1 of 2
System Sensor, Unincorporated Div of Honeywell lnt'l lnc.3825 Ohio Ave, St. Charles, IL
60174
Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309
Email: megan.sisson@honeywell.com
System Sensor Indoor 2-wire and *4-wire Models:
HWL, HRL, HGWL and HGRL Horns;
CHWL and CHRL Chimes;
P2RLI P2WL,!P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL
Wall Horn Strobes;
PC2RL,I PC2WL, rPC4RL and *PC4WL Ceiling Horn Strobes;
CHSRL and CHSWL Wall Chime Strobes;
CHSCRL and CHSCWL Ceiling Chime Strobes;
Wall Bezel Parts:
BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG,
BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG,
BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG,
BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG,
Ceiling Bezel Parts:
BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG,
BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG.
Color Lens:
LENS-A2, LENS-B2, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and
LENS-RC2.
WallTrim Rings:
*TR-2 and *TR-2W
CeilingTrim Rings:
*TRC-2 and *TRC-2W.
Wall Surface Mounted Back Boxes:
SBBRL, SBBGRL, SBBWL and SBBGWL,
Ceiling Surface Mounted Back Boxes:
Revision 08-21-2017 dee
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued:
Authorized By:
July 01, 2020
DAVID CASTILLO,, M.E., F.P.E.
Fire Engineering Division
Listing Expires June 30, 2021
RATING:
INSTALLATION:
MARKING:
APPROVAL:
Listing No. 7135-1653:0503
Page 2 of 2
SBBCRL and SBBCWL
MP120KL 120 VAC Adapter Mounting Plate
Refer to listee's data sheet for detailed product description and operational considerations.
12 voe regulated and 24 VDC/FWR
In accordance with listee's printed installation instructions, NFPA 72, applicable codes &
ordinances and in a manner acceptable to the authority having jurisdiction.
Listee's name, model number, electrical rating, and UL label.
Listed as audible devices when used with separately listed compatible fire alarm control
units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be
consulted prior to installation. Refer to listee's Installation Instruction Manual for details.
Revision 08-21-2017 dee
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued:
Authorized By:
July 01, 2020
DAVID CASTILLO,, M.E., F.P.E.
Fire Engineering Division
Listing Expires June 30, 2021
LISTING No.
CATEGORY:
LISTEE:
DESIGN:
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
7125-1653:0504 Page 1 of 2
7125--FIRE ALARM DEVICES FOR THE HEARING IMPAIRED
System Sensor, Unincorporated Div of Honeywell lnt'I lnc.3825 Ohio Ave, St. Charles, IL
60174
Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309
Email: lisa.brant@honeywell.com
System Sensor Indoor 2-wire Models:
SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT
Wall Strobes·
SCRL,ISCWL ~nd SCWL-CLR-ALERT Ceiling Strobes.
Wall Bezel Parts:
BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG,
BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG,
BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG,
BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG,
Ceiling Bezel Parts:
BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG,
BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG.
Color Lens:
LENS-A2, LENS-B2, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and
LENS-RC2.
WallTrim Rings:
TR2 and TR2W
CeilingTrim Rings:
TRC2 and TRC2W.
Wall Surface Mounted Back Boxes:
SBBRL, SBBGRL, SBBWL and SBBGWL,
Ceiling Surface Mounted Back Boxes:
SBBCRL and SBBCWL
Refer to listee's data sheet for detailed product description and operational considerations.
*Rev 04-04-1 9 gt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued:
Authorized By:
July 01, 2021
DAVID CASTILLO,, M.E., F.P.E.
Fire Engineering Division
Listing Expires June 30, 2022
RATING:
INSTALLATION:
MARKING:
APPROVAL:
Listing No. 7125-1653:0504
Page 2 of 2
Regulated 12 voe setting: 8-17.5 voe
Regulated 24 voetfwr setting: 16-33 voe
In accordance with listee's printed installation instructions, NFPA 72, applicable codes &
ordinances and in a manner acceptable to the authority having jurisdiction.
Listee's name, model number, electrical rating, and UL label.
Listed as two wire strobe units used for synchronous application when used with separately
listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal
ceiling mounted. *Listed with software code, S05-0048-001 for low temperature
compensation. Authority having jurisdiction should be consulted prior to installation. Refer to
listee's Installation Instruction Manual for details.
*Rev 04-04-19 gt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued:
Authorized By:
July 01, 2021
DAVID CASTILLO,, M.E., F.P.E.
Fire Engineering Division
Listing Expires June 30, 2022
!EXISTING SHOWN FOR CALCULATION REFERENCE ONLY.
~~SYSTEM
'-.~ SENSOR"
Indoor Selectable-
Output Horns,
Strobes, and
Horn Strobes for
Wall Applications
System Sensor L-Series audible visible notification
products are rich with features guaranteed to cut
installation times and maximize profits with lower
current draw and modern aesthetics.
Features
• Updated Modern Aesthetics
• Small profile devices for Horns and Horn Strobes
• Plug-in design with minimal intrusion into the back box
• Tamper-resistant construction
• Automatic selection of 12-or 24-volt operation at 15 and 30
candela
• Field-selectable candela settings on wall units:
15, 30, 75, 95, 110, 135, and 185
• Horn rated at 88+ dBA at 16 volts
• Rotary switch for horn tone and two volume selections
• Mounting plate for all standard and all compact wall units
• Mounting plate shorting spring checks wiring continuity before
device installation
• Electrically compatible with legacy SpectrAlert and SpectrAlert
Advance devices
• Compatible with MDL3 sync module
• Strobes and Horn Strobes listed for wall mounting only
• Horns listed for wall or ceiling use
Agency Listings
SIGNALING
@
LISTED
S5512
S4011
<8> APPROVED
FM approved except
for ALERT models
3057383, 3057072
a ~
7125-1653:0504
7135-1653:0503
The System Sensor L-Series offers the most versatile and
easy-to-use line of horns, strobes, and horn strobes in the industry
with lower current draws and modern aesthetics. With white and red
plastic housings, standard and compact devices, and plain, FIRE,
and FUEGO-printed devices, System Sensor L-Series can
meet virtually any application requirement.
The L-Series line of wall-mount horns, strobes, and horn strobes
include a variety of features that increase their application versatility
while simplifying installation. All devices feature plug-in designs
with minimal intrusion into the back box, making installations fast
and foolproof while virtually eliminating costly and time-consuming
ground faults.
To further simplify installation and protect devices from construction
damage, the L-Series utilizes a universal mounting plate for all
models with an onboard shorting spring, so installers can test wiring
continuity before the device is installed.
Installers can also easily adapt devices to a suit a wide range
of application requirements using field-selectable candela settings,
automatic selection of 12-or 24-volt operation, and a rotary switch
for horn tones with two volume selections.
AVDS865-05 • 2/22/2018 • Page 1
L-Series Specifications
Architect/Engineer Specifications
General
L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x Fie-inch back box, 4 x 4 x 1 ½-inch back box, 4-inch
octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 x 4 x 17/e-inch back box. A universal
mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be
used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series
products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output
and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs
shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor
L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.
Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185.
Strobe
The strobe shall be a System Sensor L-Series Model ___ listed to UL 1971 and shall be approved for fire protective seNice. The strobe
shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible
signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and
associated lens/reflector system.
Horn Strobe Combination
The horn strobe shall be a System Sensor L-Series Model ___ listed to UL 1971 and UL 464 and shall be approved for fire protective
seNice. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act
requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist
of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a
temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe
models shall operate on a coded or non-coded power supply.
Synchronization Module
The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective seNice. The
module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns
on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/a-inch back box. The module shall also
control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more
synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply.
Physical/Electrical Specifications
Standard Operating Temperature 32°F to 120°F (0°C to 49°C)
Humidity Range 10 to 93% non-condensing
Strobe Flash Rate 1 flash per second
Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1
Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal)
Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal)
Input Terminal Wire Gauge 12 to 18 AWG
Wall-Mount Dimensions (including lens) 5.6"L x 4.T'W x 1.91"0 (143 mm L x 119 mm W x 49 mm D)
Compact Wall-Mount Dimensions (including lens) 5.26" L x 3.46" W x 1.91" D (133 mm L x 88 mm W x 49 mm D)
Horn Dimensions 5.6"L x 4.T'W x 1.25"0 (143 mm L x 119 mm W x 32 mm D)
Compact Horn Dimensions 5.25" L x 3.45" W x 1.25" D ( 133 mm L x 88 mm W x 32 mm D)
1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs.
2. Strobe products will operate at 12 V nominal only for 15 cd and 30 ed.
AVOS865-05 • 2/22/2018 • Page 2
UL Current Draw Data
UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS)
8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33Volts
Candela DC DC FWR Sound Pattern dB DC DC FWR
Candela 15 88 43 60 Temporal High 39 44 54
Range 30 143 63 83 Temporal Low 28 32 54
75 N/A 107 136 Non-Temporal High 43 47 54
95 N/A 121 155 Non-Temporal Low 29 32 54
110 N/A 148 179 3.1 KHz Temporal High 39 41 54
135 N/A 172 209 3.1 KHz Temporal Low 29 32 54
185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54
3.1 KHz Non-Temporal Low 28 29 54
Coded High 43 47 54
3.1 KHz Coded High 42 43 54
UL Max. Current Draw (mA RMS), Wall Horn Strobe, Candela Range (15-185 cd)
8-17.5 Volts 16-33 Volts
DC Input 15cd 30cd 30cd 75cd 95cd 110cd 135cd 185cd
Temporal High 98 158 74 121 142 162 196 245
Temporal Low 93 154 44 65 111 133 157 184 235
Non-Temporal High 106 166 73 94 139 160 182 211 262
Non-Temportal Low 93 156 51 71 119 139 162 190 239
3.1 K Temporal High 93 156 53 73 119 140 164 190 242
3.1 K Temporal Low 91 154 45 66 112 133 160 185 235
3.1 K Non-Temporal High 99 162 69 90 135 157 175 208 261
3.1 K Non-Temporal Low 93 156 52 72 119 138 162 192 242
16-33 Volts
FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd
Temporal High 83 107 156 177 198 234 287
Temporal Low 68 91 145 165 185 223 271
Non-Temporal High 111 135 185 207 230 264 316
Non-Temportal Low 79 104 157 175 197 235 283
3.1 K Temporal High 81 105 155 177 196 234 284
3.1 K Temporal Low 68 90 145 166 186 222 276
3.1 K Non-Temporal High 104 131 177 204 230 264 326
3.1 K Non-Temporal Low 77 102 156 177 199 234 291
Horn Tones and Sound Output Data
Hom and Hom Strobe Output (dBA)
8-17.5 16-33
Switch Volts Volts
Position Sound Pattern dB DC DC FWR
Temporal High 84 89 89
2 Temporal Low 75 83 83
3 Non-Temporal High 85 90 90
4 Non-Temporal Low 76 84 84
5 3.1 KHz Temporal High 83 88 88
6 3.1 KHz Temporal Low 76 82 82
7 3.1 KHz Non-Temporal High 84 89 89
8 3.1 KHz Non-Temporal Low 77 83 83
9* Coded High 85 90 90
10* 3.1 KHz Coded High 84 89 89
* Settings 9 and 10 are not available on 2-wire horn strobes. Temporal coding must
be provided by the NAC. If the NAC voltage is held constant, the horn output remains
constantly on.
AVDS865-05 • 2/22/2018 • Page 3
L-Series Dimensions
--------1.91'
5.27'
133.9mm
3.46"
88mm
48.5mm
-------1.25" 32mm
A0548-00
Compact Strobe, Horn Strobe
5.67"
(14.4cm)
4.70"
(11.94cm)
Strobe, Horn Strobe
1.91"
(4.85cm)
1.25"
(3.18mm)
A0550-00
L-Series Ordering Information
Model Description
Wall Horn Strobes
P2RL 2-Wire, Horn Strobe, Red
P2WL 2-Wire, Horn Strobe, White
5.27"
133.9mm
5.67"
144mm
P2GRL 2-Wire, Compact Horn Strobe, Red
P2GWL 2-Wire, Comp 2 fils act Horn Strobe, White
P2RL-P 2-Wire, Horn Strobe, Red, Plain
P2WL-P 2-Wire, Horn Strobe, White, Plain
P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO
P2WL-SP 2-Wire, Horn Strobe, White, FUEGO
P4RL 4-Wire, Horn Strobe, Red
P4WL 4-Wire, Horn Strobe, White
Wall Strobes
SRL Strobe, Red
SWL Strobe, White
SGRL Compact Strobe, Red
SGWL Compact Strobe, White
SRL-P Strobe, Red, Plain
SWL-P Strobe, White, Plain
SRL-SP Strobe, Red, FUEGO
SWL-CLR-ALERT Strobe, White, ALERT
3.46"
88mm
A0547-00
1.55"
(3.9cm)
A0557-00
Compact Horn Compact Wall Surface Mount Back Box
SBBGRL, SBBGWL
rT 1.25'
1
r11 32mm
5.78"
:14.68cm)
4.82'
(12.24cm) -----1.85'
(4,69cm)
0
Horn A0549-00 A0554-01
Wall Surface Mount Back Box
SBBRUSBBWL
Model Description
Horns*
HRL* Horn, Red
HWL* Horn, White
HGRL* Compact Horn, Red
HGWL* Compact Horn, White
Accessories
TR-2 Universal Wall Trim Ring Red
TR-2W Universal Wall Trim Ring White
SBBRL Wall Surface Mount Back Box, Red
SBBWL Wall Surface Mount Back Box, White
SBBGRL Compact Wall Surface Mount Back Box, Red
SBBGWL Compact Wall Surface Mount Back Box, White
Notes:
All -P models have a plain housing (no "FIRE" marking on cover).
All -SP models have "FUEGO" marking on cover.
All -ALERT models have "ALERT" marking on cover.
*Horn-only models are listed for wall or ceiling use.
~\SYSTEM C~ SENSOR~
3825 Ohio Avenue• St. Charles, IL 60174
Phone: 800-SENSOR2 • Fax: 630-377-6495
www.systemsensor.com
©2018 System Sensor.
Product specifications subject to change without notice. V,s1t systemsensor.com
for current product information, including the latest version of this data sheet.
AVDS865-05 • 2/22/2018