HomeMy WebLinkAbout2810 WHIPTAIL LOOP; 201; FPC2021-0155; PermitPERMIT REPORT Fire Permit Print Date: 12/27/2021 Job Address: 2810 WHIPTAIL LOOP, # 201, CARLSBAD, CA 92010-6753 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel#: Valuation: Occupancy Group: #of Dwelling Units: 2091202800 Track#: $92,182.82 Lot#: Project#: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Project Title: Description: NIXON -SPRINKLER Tl (16 HEADS) Applicant: AMERICAN AUTOMATIC FIRE SUPPRESSION INC KELLY SANTOS 9925 PROSPECT AVE, # STE B SANTEE, CA 92071-4376-SAN DIEGO (619) 562-3010 FEE FIRE NFPA 13 or 13R System 7-100 heads Total Fees: $553.00 Fire Department Total Payments To Date: $553.00 (city of Carlsbad Permit No: FPC2021-0155 Status: Closed -Finaled Applied: 08/18/2021 Issued: 08/26/2021 Fina led Close Out: 12/27/2021 Inspector: Final Inspection: FPContractor: AMERICAN AUTOMATIC FIRE SUPPRESSION INC 9925 PROSPECT AVE, # STE B SANTEE, CA 92071 (619) 562-3010 Balance Due: AMOUNT $553.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov 1:q :i!'!otection Worldwide Contacts www.tyco-fire.com Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: • A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. • A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 1¢Mi@#I The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Nu,nber (SIN} TY313 ....... Upright 5.6K, 1/2" NPT TY323 ...... Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* * The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi112 (80,6 LPM/bar112) FEBRUARY 2014 Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C} 200°F (93°C) 286°F (141°C} Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ................... Bronze Button .............. Brass/Copper Sealing Assembly ......... Stainless Steel w/TEFLON Bulb ...................... Glass Compression Screw ........ Bronze Deflector ................. Bronze TFP172 TFP172 Page 2 of 4 Components: 1 -Frame 2 -Button 3 -Sealing 4 -Bulb 5 -Compression Screw * Temperature rating is indicated on Deflector. ** Pipe thread connections per ISO 7-1 can be provided on special request. Assembly 6 -Deflector* DEFLECTOR * ESCUTCHEON PLATE 1/2" 7/16" (11,1 mm) SEATING SURFACE NPT** NOMINAL MAKE-IN STYLE 15 or 20 RECESSED ESCUTCHEON 7/16" (11,1 mm) NOMINAL MAKE-IN ,-~ I ~t 2" I ~IJ __ [lo (50,8 mm) l___ 1-3/8" (34,9mm) I J i WRENCH FLATS DEFLECTOR* I-2-7/8" (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE WRENCH RECESS (USE ONLY END "A") FIGURE2 W-TYPE6 SPRINKLER WRENCH WRENCH RECESS t PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141 °C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under-or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. FACE OF SPRINKLER FITTING 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) 3/8±5/16" '71~ (9,5±7,9 mm) v~ t I MOUNTING SURFACE a;::::c;:a:::s:~ 1/8" (3,2 mm) CLOSURE SERIES TY-FRB MOUNTING PLATE FIGURE 4 TFP172 Page 3 of 4 5/8" (15,9 mm) FLUSH 1-3/8" (34,9 mm) 3/4" (19,1 mm) SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER FITTING 2-1/4" DIA. ,__..___(57--.,2 mm) ~I 5/16±1/4" (7,9±6,4 mm) ~-~-----t~~-- MOUNTIN SURFACE 1/2" (12,7 mm) FLUSH /:/ ==l_J_ 1/8" (3,2 mm) t /~ a;::::c;a::::&;~ CLOSURE SERIES TY-FRB MOUNTING PLATE 1-3/8" (34,9 mm) 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. TFP172 Page 4 of 4 P/N* 77 -XXX -X -XXX I I I SPRINKLER FINISH SIN 1 NATURAL BRASS 370 5.6K UPRIGHT (1/2" NPT) TY313 3 PURE WHITE (RAL9010)** POLYESTER 371 5.6K PENDENT (1/2" NPT) TY323 4 SIGNAL WHITE (RAL9003) POLYESTER • Use suffix "I" for ISO 7-1 connection; 9 CHROME PLATED for example, 77-370-4-175-1 •· Eastern Hemisphere sales only TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS Lilnited Warranty For warranty terms and conditions, visit www.tyco-fire.com. PART NUMBER SELECTION Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 TEMPERATURE RATINGS 135 135°F (57°C} 155 155°F (68°C} 175 175°F (79°C} 200 200°F (93°C} 286 286°F (141°C} GLOBAL HEADQUARTERS I 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright© 2014 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. 'ti./ fife ~tection Products Ill Malleable Iron Threaded Pipe Unions Pressure -Temperature Ratings Temperature Pressure Class 150 Class 250 Class 300 (OA 1°e) psi bar DSi bar psi bar -20° -28.9° to to 300 20.7 500 34.5 600 41.4 150° 65.6° 200° 93.3° 265 18.3 455 31.4 550 37.9 250° 121.1 ° 225 15.5 405 27.9 505 34.8 300° 148.9° 185 12.8 360 24.8 460 31.7 350° 176.7° 150 10.3 315 21.7 415 28.6 400° 204.4° 110 7.6 270 18.6 370 25.5 450° 232.2° 75 5.2 225 15.5 325 22.4 500° 260.0° --180 12.4 280 19.3 550° 287.8° --130 9.0 230 15.9 Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F <a> APPROVED For Listings/Approval Details and Limitations, visit our website@ www.anvilintl.com or contact an Anvil/AnvilStar Sales Representative. MALLEABLE IRON Malleable Iron Threaded Fittings Pressure -Temperature Ratings Pressure Temperature Class 300 Class 150 Sizes ¼"-1" Sizes 1 ¼"-2" Sizes 2½"-3" (6-25 mm) (32-51 mm) (64-76 mm) (OF} (0e) psi bar psi bar psi bar psi bar -20° -28.9° to to 300 20.7 2,000 137.9 1,500 103.4 1,000 68.9 150° 65.6° 200° 93.3 265 18.3 1,785 123.1 1,350 93.1 910 62.7 250° 121.1 225 15.5 1,575 108.6 1,200 82.7 825 56.9 300° 148.9 185 12.8 1,360 93.8 1,050 72.4 735 50.7 350° 176.7 150 10.3 1,150 79.3 900 62.1 650 44.8 400° 204.4 --935 64.5 750 51.7 560 38.6 450° 232.2 --725 50.0 600 41.4 475 32.8 500° 260.0 --510 35.2 450 31.0 385 26.5 550° 287.8 --300 20.7 300 20.7 300 20.7 Ill C: 0 ~ E I Anvil Class 150/300 Malleable Iron Fittings conform to ASME c: Bl6.3 and Unions conform to ASME Bl6.39. i ALL ELBOWS & TEES ¾" (10 DN) and LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. (6.9 bar) c.., www.anvilintl.com 17 PF-11.10 c®usLISTED <§> BULL MOOSE TUBE COMPANY APPROVED c®usLISTED <§> APPROVED 2 Bull Moose Tube® is a customer focused, growth oriented manufacturer and marketer of tubular products, where success is based on a commitment to meeting the customer's perception of quality. Our strength resides in our people working together to satisfy customers and to promote business growth by achieving superior financial performance. www.BullMooseTube.com sales@bullmoosetube.com 800.325.4467 BULL MOOSE TUBE COMPANY Bull Moose Tube's® "Eddy Pipe®" brand sprinkler pipe is produced to meet sprinkler pipe standards and applications. c®usLISTED <§> APPROVED Ci.] NFP~ A ONFSA American,... .,.. ... ., ...... __..........., SprinkJff Association ADVANTAGES OF BULL MOOSE TUBE® EDDY PIPE® FAMILY • All pipe products are UL Listed (for U.S. and Canada}, and have been approved by Factory Mutual. • Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. • All products are certified to ASTM A 135 and A795 Type E, Grade A. • Available in specific cut to order lengths from regular mill rollings. • More popular sizes available with coating or bare. • Ultra Eddy®, Eddy Flow®, Eddylite®, and Eddythread 40® offer cost savings along with superior hydraulics without compromising service life. • Sprinkler pipe inventory stocked in Masury, Ohio; Gerald, Missouri; Casa Grande, Arizona; Kent, Washington; and Dallas, Texas. • All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD II® MIC preventative coating. • Bull Moose Tube® sprinkler pipe is FBC™ compatible. PRODUCTS • Schedule 10 and Schedule 40: FM approved and UL listed sprinkler pipe. • Eddythread 40®: Light threadable Schedule 40 replacement with corrosion resistance ratio of 1.0. • Eddylite®: Lightwall threadable with standard outside diameter. • Eddy Flow®: Cost effective replacement for Schedule 10. • Ultra Eddy®: Lightwall roll groovable pipe. • Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM A 123 standards. All products are stencilled to meet FM & UL specifications. PROTECTION • Eddy Guard II®: Bull Moose Tube® is producing product that can resist bacteriological growth even after multiple rinse-outs. You know MIC corrosion can impact your installation and your property. Specify Bull Moose Tube® "Eddy Guard II®" and feel comfortable knowing that you are getting Eddy Pipe® product you trust with the bacteria resistance you need. Eddy Guard II® is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information contained herein is accurate as known at the time of publication. Bull Moose Tube® reserves the right to change product specifications without notice and without incurring obligation. 3 Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM A 123 standards. All products are stencilled to meet FM & UL specifications. c®usLISTED <:g> APPROVED II) NFP• ONFSA American,...... .... ..................... ....., Sprinl,.i..Aasoclatlon 4 SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1.820 1-1/4 1-1/2 2 4.223 2-1/2 4.92 5.893 30 3 3.54 4 2.50 5.62 lbs/ft 11.796 19 S C HEDULE 40 PIPE SPECIFIC ATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE _J !_ ~L--1.Q.49 C "l'.' - 1 1.315 1.00 -----1:§8 lbs/ft 2.055 70 ' -- 1-1/4 1.660 1.380 1.00 2.27 lbs/ft 2.918 51 1-1/2 -,:-900--1.610 -1.00 r---2.12 l bstft -3.602 ~ --44 -------------""----·---...__ --- 2 2.375 2.067 1.00 3.66 lbs/ft 5.114 lf<c-•· •"• 30 2-1/2* ...--~ --2.468 1.00 ___ 5.80 lbs/ft ·-~ 7.875 30 --2.875 3* 3.500 3.068 1.00 7.58 lbs/ft 10.783 ( 19 4* ___ 4.500 -4.026 --1.00 = [ i 0.80 lbs/ft =c -19 - ---16.316,_ --*Only available in Casa Grande, AZ **Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. BULL MOOSE TIJBE COMPANY For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Clarkson Road Chesterfield, MO 63017 Gerald, MO Kent,WA Casa Grande, AZ www.bullmoosetube.com sales@bullmoosetube.com Dallas, TX Masury, OH Firelock® Outlet-T STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, ¾, and l "/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 1 ¼ through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. JOB/OWNER System No. __________ _ Location ___________ _ Gasket: • Grade "E" EPDM -Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel (North America, Latin America, Asia Pacific) • Red enamel (Europe) CONTRACTOR ENGINEER Submitted By ________ _ Spec Sect _____ Para ___ _ Date ____________ _ Approved __________ _ IPS CARBON STEEL PIPE -HOLE CUT PRODUCTS 10.52 Firelock® Outlet-T STYLE 922 DIMENSIONS Nominal Size I Hole I I Approx. inches/mm Diameter Dimensions -mches/m1lhmeters Weight Each Run X Branch +0.06/+1.5 FPH -0.00/-0.0 T* V w y z lbs/kg l¼ X ½ l3/i6 1.30 1.83 1.10 3.87 2.56 1.0 32 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45 ¾ l3/i6 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1 l3/i6 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 ----------·--.__ ---l½ X ½ l3/i6 1.42 1.95 1.22 4.08 2.56 1.2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 ¾ 13/16 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 ··----------·-·----- 1 13/16 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 ------------2 X ½ P/i6 1.66 2.19 1.46 4.60 2.56 1.3 50 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 --¾ Pli6 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 13/16 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 2½ X ½ l3/i6 1.91 2.44 1.71 5.40 2.56 1.6 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 ¾ P/i6 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 l3/i6 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 76.1 mm X ½ l3/i6 1.91 2.44 1.71 5.50 2.56 1.6 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 ¾ l3/i6 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 ·---- 1 l3/i6 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads (dimensions are approximate). - - IPS CARBON STEEL PIPE -HOLE CUT PRODUCTS 10.52 Firelock® Outlet-T STYLE 922 PERFORMANCE I Equivalent Length of I inch Schedule 40 Steel Pipe (per UL Run Size x Outlet Size 213, Section 16) (C:120)*, FT Inches/mm Feet/meters 1¼ X 1 8.5 32 25 2.6 1½ X 1 8.5 40 25 2.6 2 X 1 8.5 50 25 2.6 2½ X 1 8.5 65 25 2.6 76.1 mm X 1 8.5 25 2.6 * Hazen-Williams coefficient of friction is 120 Firelock® Outlet-T STYLE 922 INSTALLATION WARRANTY NOTE Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. @@/Ji) P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 300 RING HANGER 1 thru 4 inch pipe LISTED FOR STEEUCPVC 1/2 & 3/4 inch pipe 5 thru 8 inch pipe SIZE -ROD-3/8" or 1/2" SIZE -SYSTEM PIPE -1/2" thru 8" MATERIAL -Carbon Steel, Mil. Galvanized to G-90 spec. LISTING/APPROVAL - c~us 203-EX 2551 1 "-8" <§> Approval guide -1 "-8" OSHPD OPA-060 I See Website. CONFORMS WITH: Federal Specification WW-H-l 71E, Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE -650°F. FUNCTION -Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe. INSTALLATION -Per NFPA 13, 13R, 13D, these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES- * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING -Part#, pipe size. 11/09 PIPE ROD 1 3/8 11/4 3/8 1 1/2 3/8 2 3/8 21/2 3/8 3 3/8 4 3/8 5 1/2 6 1/2 8 1/2 NFPA 13 UL 1WT. 5 WT.+250 TEST LOAD 30.75 403.75 750 43.95 469.75 750 54.15 520.75 750 76.95 634.75 750 118.35 841.75 850 162.30 1061.50 1050 246.00 1480.00 1500 349.45 1996.75 2000 476.35 2631.75 2650 711.00 3805.00 4050 PIPE A B 1 1.8793 2.5259 11/4 2.1382 2.7850 11/2 2.2673 2.9140 2 2.6048 3.2516 21/2 3.4920 4.1150 3 3.7845 4.4311 4 4.3582 4.9992 6 6.0668 6.8180 8 7.5768 8.3290 @@/j) P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 310 RING RESTRAINER t Restraint SIZE -One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. MATERIAL-Carbon Steel. FINISH -Mil. Galvanized. LISTINGS -~ c\e/us 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION -To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION -Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL OTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES- * Listed only for use with AFCON #300 Ring Hanger. ORDERING -Part# and size. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised tl1e following warranty restriction will apply. DISCLAIMER -AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limiled to loss of business or profit, when non-AFCONproducts have been, or are used. 1/08 2' nominal width ~ 1/4" 1/4" 3/8" ~ 3/8" :@. .. ~ 3/8" 3/8" y 3/8" ~~ 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 1/2" 1/2" 1/2" Not less than 3" nominal thickness (2-1/2") (depth or side f vertical member) 8003957 8004957 8006957 8007957 8008957 8068925 8009925 8010957 8069925 8011925 8012925 8013925 8014925 8015925 8016925 8017925 GST 200 GSJ 300 GST .75 GST10 GST 20 GST 20-SS GST 25-380 GST30 GST 30-SS GST40 GST60 GST2 GST 2.5-380 GST3 GST4 GST6 1/4 X 2" 1/4x 3" 1/4 X 3/4" 1/4x 1" 1/4 X 2" 1/4x 2" Composite I Truss Consult truss manufacturer for recommended mstallation point I •Pre-dnlling may be required for GST 25-380. Tool available on page 10. 1760 (Fir) 2060 (Fir 564 (3/4" Ply) 210 (7/16" OSB) 670 (3/4" Ply) 1760 (Fir) 1760 Fir 300 850 850 3/8 X 2-1/2" 2113 (Fir) 1500 1/4x 3" 2060 Fir 1500 1/4 X 3" 2060 (Fir) 1/4x4" 2180 Fir 1/4 X 6" 2230 (Fir) 1/4x 2" 1760 Fir 3/8 X 2-1/2" 2113 (Fir) 1/4x 3" 2275 (Fir) 1/4 X 4" 2180 (Fir) 1/4x6" 2230 Fir • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation cost. • Made in the U.S.A. 25 25 25 25 1475 25 25 25 1475 25 25 25 25 25 25 25 25 25 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 #14 Black Nut Driver Part#8113910 14SWRed Nut Driver Part#8114910 SAMMY Swivel HeacfID for Wood Product Features • Eliminates distortion of threaded rod. • Saves time from traditional methods. • Accommodates up to 3 ½" x 12 pitch roof. • Allows 17° deflection from vertical. Nut Driver nd safe installation each time. When the face of the driver comes into Part# 811391 o Warranty requires the use of the appropriate nut driver for installations . • Not less than 2• nominal width (1-1/2") up to 3-1/2" pipe; not less than 3· (2-112·) nominal width 4· & s· pipe .._... I Minimum 2-1/2" from bottom for branch lines. Minimum 3• from bottom for main lines. Exception: This requirement shall not apply to 2" or thicker nailing strips resting on top of steel beams. )' Floor Joist • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation cost. • Made in the U.S.A. A I Rod Part M d I Screw Ultimate UL Test Box Case pprova s Size Number O e Descriptions Pullout (lbs) Load (lbs) Qty Qty 1/4 8018957 1/4" 8019957 3/8" 8020957 3/8" 8021957 I 3/8" 8073925 #14 SW Red 3/8" 8022925 Nut Driver 3/8" 8023925 Part# 8114910 VERTICAL 1. Insert the appropriate nut driver into a 318" or 112" portable drill. 2. Insert the SAMMYS into the #14 (black) nut driver (pin 8113910). Drill should be in a vertical position. 3. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. 4. The SAMMYS is now ready to receive 114", 318", 112" or metric all thread rod, bolt stock. (The 112" requires the #14SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. SWG100 SWG 200 SWG10 SWG20 SWG 20-SS SWG 25-380 SWG30 1/4X 1 622 Fir 25 125 1/4x 2" 1725 (Fir) 25 125 1/4x 1" 622 Fir 300 25 125 1/4 X 2" 1725 (Fir) 1050 25 125 1/4x2" 1725 Fir 850 25 125 3/8 X 2-1/2" 2249 (Fir) 1500 25 125 1/4x3' 1884 Fir 25 125 HORIZONTAL 1. Insert the appropriate nut driver into a 318" or 112" portable drill. 2. Insert the SAMMYS into the #14SW (red) nut driver (pin 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. 3. When the nut driver spins free on the SAMMYS, stop the drill and remove. 4. The unit is now ready to receive 114", 318" or metric all thread rod or bolt stock. Note: When installing SWOR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.