HomeMy WebLinkAbout1606 JAMES DR; ; CBR2020-0235; PermitBuilding Permit Finaled Residential Permit Print Date: 09/28/2021 Job Address: Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: Code Edition: Sprinkled: Project Title: 1606 JAMES DR, CARLSBAD, CA 92008-1956 BLDG-Residential Work Class: 1562110900 Track#: $105,238.56 Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Addition ( City of Carlsbad Permit No: CBR2020-0235 Status: Applied: Issued: Finaled Close Out: Inspector: Final Inspection: Closed -Finaled 01/30/2020 03/11/2020 PBurn 09/28/2021 Description: CONROY: 604 SF ADDITION TO 1ST & 2ND FLOOR (2BED & 2BATH) // 232 SF COVERED PATIO Applicant: Property Owner: GREG JORDAN PO BOX 947 CONROY FAMILY REVOCABLE TRUST 09-29-15 1606 JAMES DR SOLANA BEACH, CA 92075-0947 (858) 775-5169 FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) CARLSBAD, CA 92008 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium BLDG SWPPP PLAN REVIEW FEE TIER 1-MEDIUM Total Fees: $1,935.09 Total Payments To Date: $1,935.09 CoApplicant: ROBERT RATAJCZAK 3990 ALDER AVE CARLSBAD, CA 92008-3601 (760) 224-8748 Balance Due: AMOUNT $647.30 $453.11 $66.00 $175.00 $92.00 $182.00 $5.00 $13.68 $246.00 $55.00 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as 11fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov ( City of Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Plan Che<kc.J2£2!'220-D23S Est. Value IOo, 239 -j PC Deposit----------- 0 ate J-:-:3)----=-aL_ Job Address~-'-/-""-'(-'~'-'(_··"-, ·_·,cc· ~Y-,_-~~-;_,-_~_\_· _·_\>_i_1_, vl-'C_-____ Suite: _____ APN: _. "-C::_( _-'1-~"'-1 _, _-_~_:-t'_-~/(_··_C_(~--·; CT/Project#: __________________ Lot#: ___ _ ,--·-- Fire Sprinklers: v~s / -~ BRIEF DESCRIPTION OF WORK: Ct:--q ,;:r Remodel: Sf of affected ared Is the df'ea a conversion or change of use? Yes/ No O Pool/Spa: ____ SF Additional Gi'\s or Elect1•ica! Features? O Solar: ___ KW, Modules, Mounted: Roof I Ground, Tilt: Yes/ No, RMA: Yes/ No, Battery·. Yes/ No Panel Upgrade: Yes/ No ..J Reroof: _______________________________________ _ ..J Plumbing/Mechanical/Electrical Only: :J Other: Architect State License: ___________ _ LONTRACTOR BUSINES5 Name: ~ /2.oZA. j::_ ¼sfYUC-fu Address: -~ "7 o /JaoVkr: A,ce, City: 0«:: fr kJ State:.ffi_Zip: q '2&0 ~ Phone: 7" I,, O 2 '2 ':f -r:. t '1 ir Email: z.,:.../<-u"' f State License: 1J {f6 '2.7 iSec. 7031.5 Bu~1nes~ Jnd Prole~\1on~ Code· 1'1..n·1 C11y or County which requ1rp5 ,:; p,.-·rm,t to con.,tn,ct. ,11tf'f, 1rnp1ovt' ctfc'rr1ol1,h CH r;,p,11r dni' ,tructure<, pr,01 to 1r, 1>•,uame, ahu • quires the appl,c;ml fo( \uch pNmit t:. filp a s1sned ,;tat.•ment th.1t he ··,he .~ l1Ct'll\t'd pur~,1.-rnt to the p1 u-.,)1on:, ut thf' ContrJttor''. Liceri-..f> Li•"- (C.h"'lph~r 9. rnmmend1n,", with St'ct1on 7000 c/ 01v1:;ion 3 ot the Busme~s al'ld Pr,)k,;,1e1n~ (odr I or th,1\ hr:/~hl' ir e~empt theretroni, ,lnd th,.-b<Vi1s tor the all,?ped (',H•mpt,on t..nv ,,1O\-1t,or, al St>tl.,on 70-U ::, by ;in•, ,,ppl,cJnt tor ,1 pdrn11 •:ub,-,.1.', the· :iprhc,mt t0 ;; c1i1I pc,nc1ily of no·. 1litnP U1~n t,11o:c hui.d;':'d (joiL11, -.~soup 1635 Faraday Ave Carlsbdd, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 ( OPTION A) WORKERS'COMPEN~ATION DECLARATION. I heorby affirm under penalty of perjury Q!1f. of the following declarations: Q1 have and will m,,inl.im a cert1f1c,HP ot con\<•nt to wit m\ure for wo1k1,r< comprn,at1011 prov1dPd by Si>rt1on 3700 of 1hP L.ibor CodP for the P<•rform,in<t' of !ht> work which th1> pprm1t I\ IS~UPd 01 h,ive .-111d will m,rn1t.im workN\ compen~,1t1on. a~ requ1rt>d by Section 3700 ot the Labor Codt>, for the perform.incl' ot tlw work for wh,ch th,~ p1.!r,l'l1t 1\ ,swed My worke-rs' compPn\dlion rmur,rncr-c.irrwr ,;1r,d pol1ry n11mber MP: Insurance Companv Name:---~------------------------- Policy No, __________ _ ___ hpiration Date: ~f1catf' ot ExPrnptwn· I certify th..it 1n the p!!rforni,;1nce of the work tor whKh th1~ permit 1~ 1~\Ued. f \hall not employ .tny person m ,1ny mannPr ~o ii\ to be conw \UbJNt to thP worlw1 ,· (onipen\ation Law~ of Catiforn1<1 WARNING: Failure to secure workers compensation coveraee is unlawful, and shall subject an employer to cr,mlnal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damaaes as pro11ided for in Section 3706 of the Labor Code, interest and attorney'\ fees, CONTRACTOR SIGNATURE: l&p=. -.-_JAGENT DATE: ------,1~--+------------- 1 OPTION B ): OIA/IIIJR!,H.IIJ_QER DECLARI\TIQ1'1: I hereby affirm that I am exempt from Contractor's License Law for the following reason: Qi .. i~ownPr ot thP property or my emplOyPe~ wilh WdBP~ds their ~ole compt.>n~at,on, will do lhP work and the ~tructurP b not intended or ottered for ,,111' ISPC 7044. Bu,mp~•. ,ttHl PrOf P~s1on, Codf': ThP Coniractor·, lfrpn~e Law do<>s not apply to ,in owner of propNty who build~ or improve\ ther£•on, ,rnd who does such work h1m,elf or through h1\ own employee~, prov1dPd th,lf wch 1mp10Yt>nwn1~ MP not intended or offered for sale. !f, howPvf>f, the building or 1mprovf'mPnt 1~ c,old within onf' yedf of complet1011, thP ownN builder will h;ive th<' burde-n of provmg th,11 hp drd not build or 1mprovt> fot the pu1pose of ,ole). 0 I, ,I\ owner of thP property, am t>•clu~•Y!!ly contr,1U1rlg with l1cPn,ed contr<1ctor, to con,truct tile pro;ect {Se< 7044, BtiSmpss ,ind ProfP'>\IOm Codp Tt11.' Cofltrartor'~ L1cf'rhP l'1w doe, 11ot apply to .m owrier ol property who bwlds or improves thereon. and contrMI~ for ~uch pro1ecta; with contr.ictor/s) licPrhPd purHunt to theContr,ictor', L1cenH• Low) 0 I am P~Prnpt undpr Sl•tt;on _ _ ____ ,,__ __ _ Bu,1np~ .. ,1nd Proft>s .. lOn~ CodP for th 1, 1pa'>on 1 I P>'r\on.illy pla11 to providt> !hf' rndJOr labo1 and matn1als for construction of the propo~ed property 1mpro11ement QYES Q NO 2 I /h,1w / h.ive not) ,1g11ed an ,1pphcat1on for .l bl11ld1ng pprm1t for thP proposed work 3 I h,ive cont1aclf>d with the following persor1 (firm) to prov1dp !he propo\ed comtrun1on (include name addres~ /phone/ contracton' IKPnSP numbPr) 4 I pl,,111 to provide portions of tht:' work. but I have hired the following person to coorduldlP, \UPPrv1se ,md provide thf> maJor work (1ncludt' namP / <tddres\ / phoni• / coritr.ictor~· hcPnw number): 5. I will provide ,onw of tht' work. but I hdvf' contr,1cted !hired) tht> following per~on\ to pro..-idf' the work 1nd1catf'd (tncludf' namp / addre\s /phone/ !ypt' of work) OWNER SIGNATURE: __________________ -.JAGENT DATE: _____ _ CONSTRUCTION tfNDING IIGJlll<:Y,IF .ANY: I ht'tPby ,iffirm th,H tlwrt> l\ d con~truction lt->nd1ng .ig.•ncy for tht' performdl7Ct-> of the work th1~ permit 1) 1~)uf'd (SPc 3097 (1) C1v1I Code). Lender'i Name: lender's Address: ONLY COMPLETE THE FQLLOWING SfCTIONJQR NON-RESIDENTIAL. BUILDING P_EHMJJ5_ QNL'(: h tht> .ipp!1c,rnt 01 futLH(• burldtrlp, occup,rnt reqt1ired to \ubrnil a bu"l1t'\S pl,m, ocutPly h,u.irdou\ matt>riah rt>g1str.it1on lorm or risk mJna~Pmt•nr .ind prf''H'nt1on progr,1m undPr Section\ 25505, 25533 or 2SS34 of tht' Pr,,~ley T <tnner Haldrdom Sub\t,1nci:> Account Art7' Yes/ No h thP ,1pplic.1nt or future building occup.1111 requ1r~•d to obtain d pPrnl+t from the d1r pollu!1on cont~ol d1\tfl(t or air qudlity man.igemrnt di)\r1ct) Yes/ No I) thf' facility to be con ,tructed w1thtn 1,000 !Pet ot the outer boundary of a \thool site:> Yes/ No IF ANV OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPUCANJ CER TIFl<;A TLQN: I (Prt1fy thal I hdVf' r.-;1rl thP clppl1cat1on <1nd ,ta!P that ttw abovp ,nform,1t1011 1, correct ,ind that the information on thf' pl,in'> 1\ Mcuratf' I <tgret> to tomplv with clll City ordlf\dn(P'> dlld St,itp law, rPl,tt1np; to buildinE'. COrht1uction. l ht>reby authOntf' rppff'\\"nt.ltl\le of thf' Crty ofCarhbad to l'ntpr upan the abow,• m+>ntione-d prop{'rty tor 1mpei:t1or1 purpo'>e'>. I Al50 AGREE TO SAVE, INDEMNIFY ANO KEEP HARMLESS THE CITY Of CARLSBAD AGAINST ALL UABILITIES, JUDGMENTS, COSTS ANO EXPENSES WHICH MAY !N ANY WAY ACCRUE AGAINST SAtDClTY IN CONSEQUfNCE OF TH[ GRANTING Of THIS PfRM!T.OSHA: An OSHA pi'rrrnt 1<, fPquirf'd for l'~CdvdtlOll'> owr S'O' dPt'p ,1nd demoht1on or construction of \tructurt'~ over 3 stOrlt'\ 1n ht>ighl EXPIRATION Every pt•rm11 1ssuf"d by thP Building Of11(1al undPr the prov1',l ~ of this Code ~h.ill e~pire by hm1tation <tnd become null and void 11 the bu1ldmgor work .iuthonzed by wch p('rm1t 1<, not commenced within 180 day> from the date of such iwr r 11 the bu1td1nr, or woril <1uthor11ed by such pnm1t 1s '>Uspended or <tbandoned at any t1mP ,3ftpr thP work 1~ commt>nct>d for .-i J)Priod ol 180 d,1 '> 1 10b.4 4 Uniform Bui mg COdP) APPLICANT SIGNATURE: DATE: ftt/zt 1635 Faraday Ave Carlsbad, CA Ph: 760-602-2719 Fax: 760-602-8558 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: □ I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. O I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: ______________________ _ Policy No. --------------~Expiration Date: __________ _ □ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONTRACTOR SIGNATURE: __________________ LJAGENT DATE: _____ _ ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). f'olas owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The //onhactor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed ' pursuant to the Contractor's License Law). □ I am exempt under Section ________ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): s. I will provide some of the work, but I _.-,,,-:;:----~ allowing persons to provide the work indicated (include name/ address/ phone/ type of work): DATE: 2,,/J 1 /wze; OWNER SIGNATURE: AGENT I CONSTRUCTION LENDING AGENCY. IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued {Sec. 3097 (i) Civil Code). Lender's Name: _____________________ _ Lender's Address: _____________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D Yes D No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes D No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I Al50 AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CllY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is require exc ations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building visions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 d such permit or i the building or work authorized by such permit is suspended or abandoned at any time APPLICANT SIGNATURE: after the work is commenced for a period of niform Building e). -,L-.....,L...,L-...---------=:::::=:::::::..._ __ DATE: -------¥-~/2_':?6_,+=7/µ'----J _ 1635 Faraday Ave Carls Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov Permit Type: BLDG-Residential Application Date: 01/30/2020 Owner: TRUST CONROY FAMILY REVOCABLE TRUST 09-29-15 Work Class: Addition Issue Date: 03/11/2020 Subdivision: CA~LSBAD TCT#77-07 Status: Closed -Finaled Expiration Date: 01/24/2022 Address: 1606 JAMES DR IVR Number: 24531 CARLSBAD, CA 92008-1956 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed BLOG-Building Deficiency No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 06129/2021 06129/2021 BLDG-84 Rough 160807-2021 Passed Paul Burnette Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 07114/2021 07114/2021 BLDG-17 Interior 161894-2021 Passed Paul Burnette Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 0712712021 07127/2021 BLDG-14 162905-2021 Partial Pass Tim Kersch Reinspection Incomplete Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Dense glass 2x complete Yes 09128/2021 09128/2021 BLDG-Final Inspection 167414-2021 Passed Paul Burnette Complete Checklist Item COMMENTS Passed BLOG-Building Deficiency Yes BLDG-Plumbing Final Yes BLOG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes Tuesday, September 28, 2021 Page 2 of 2 Building Permit Inspection History Finaled (city of Carlsbad Permit Type: BLDG-Residential Application Date: 01/30/2020 Owner: TRUST CONROY FAMILY REVOCABLE TRUST 09-29-15 Work Class: Addition Issue Date: 03/11/2020 Subdivision: CARLSBAD TCT#77-07 Status: Closed -Finaled Expiration Date: 01/24/2022 Address: 1606 JAMES DR IVR Number: 24531 CARLSBAD, CA 92008-1956 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 03/02/2021 03/02/2021 BLDG-81 Underground 151733-2021 Partial Pass Paul Burnette Reinspection Incomplete Combo(11, 12,21,31) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-11 Foundation-Ftg-Piers No (Rebar) BLDG-12 Steel-Bond Beam No BLDG-21 Yes U nderg round-U nd erfl oo r Plumbing BLDG-31 Yes Underground-Conduit Wiring 03/10/2021 03/10/2021 BLDG-11 152344-2021 Passed Tim Kersch Complete Foundatlon/Ftg/Plers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 04/21/2021 04/21/2021 BLDG-15 Roof/ReRoof 155533-2021 Passed Paul Burnette Complete (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 06/17/2021 06/17/2021 BLDG-13 Shear 160099-2021 Passed Paul Burnette Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 06/28/2021 06/28/2021 BLDG-27 Shower 160738-2021 Passed Paul Burnette Complete Pan/Tubs Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-84 Rough 160689-2021 Failed Paul Burnette Reinspectlon Incomplete Combo(14,24,34,44) Tuesday, September 28, 2021 Page 1 of 2 DATE: 3/6/2020 JURISDICTION: City of Carlsbad PLAN CHECK#.: CBR2020-0235 PROJECT ADDRESS: 1606 James Dr. ✓• EsG1I SET II PROJECT NAME: Conroy Residence Remodel & Addition n LICANT 77C~1~ [8'.I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: [8'.I EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: 5 \'()\:30(by6)1 ) Email: Mail Telephone 0 REMARKS: By: David Yao EsGil Fax In Person Enclosures: 2/27/20 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 DATE: 2/17/2020 JURISDICTION: City of Carlsbad PLAN CHECK#.: CBR2020-0235 PROJECT ADDRESS: 1606 James Dr. SET: I PROJECT NAME: Conroy Residence Remodel & Addition -~LICANT %J~~IS D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [8J The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [8J The applicant's copy of the check list has been sent to: Greg Jordan D EsGil staff did not advise the applicant that the plan check has been completed. [8'.I EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Greg Jordan Telephone#: 858-775-5169 Date contacted: ~\'"\\~ (by~ ) Email: gsjordandesign@gmail.com Mail Telephone 0 REMARKS: By: David Yao EsGil Fax In Person Enclosures: 2/3/20 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: CBR2020-0235 PROJECT ADDRESS: 1606 James Dr. FLOOR AREA: Add living 604 sf Patio cover 232 sf REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 2/17/2020 FOREWORD (PLEASE READ): JURISDICTION: City of Carlsbad STORIES: 2 HEIGHT: DATE PLANS RECEIVED BY ESGIL CORPORATION: 2/3/20 PLAN REVIEWER: David Yao This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2019 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2018 IRC, 2018 IBC, 2018 UPC, 2018 UMC and 2017 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2018 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 1. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 2. On the cover sheet of the plans, specify any items that will have a deferred submittal (fire sprinklers/alarms, etc.). Additionally. provide the following note on the plans: "Submittal documents for deferred submittal items shall be submitted to the registered design professional in responsible charge, who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and that they have been found to be in general conformance with the design of the building. The deferred submittal items shall NOT be installed until their design and submittal documents have been approved by the building official." (if applicable) 3. The floor plan (sheet 3) shows the window at south wall of the proposed bedroom at upper level is number 3. It should be 5 (?). Please revise ii. 4. Glazing in the following locations should be shown on the plans as safety glazing material in accordance with Section R308.4: a) Glazing in doors. 5. Show the required ventilation for attics (or enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters). The minimum vent area is 1/150 of attic area (or 1 /300 of attic area if at least 40% (but not more than 50%) of the required vent is located no more than 3' below the ridge) and remaining vents located at the lower third of the of the attic space. Show on the plans the area reguired and area provided. Section R806.2. 6. Enclosed rafter spaces do not require venting if the following specific insulation design is used, per Sections R806.5/EM3.9.6: • If the insulation is air-permeable and it is installed directly below the roof sheathing with rigid board or sheet insulation with a minimum R-5 value installed above the roof sheathing. (or) ♦ If the insulation is air-impermeable and it is in direct contact with the underside of the roof sheathing. (or) ♦ If two layers of insulation are installed below the roof sheathing: An air- impermeable layer in direct contact with the underside of the roof sheathing and an additional layer of air permeable insulation installed directly under the air- impermeable insulation. • In climate zones 3-15, air permeable insulation installed as part of one of the previous insulation assemblies in unvented attics must comply with section R806.5.5.2 7. Where eave vents are installed, insulation shall not block the free flow of air. A minimum of 1" of air space shall be provided between the insulation and the roof sheathing. To accommodate the thickness of insulation plus the required 1" clearance, member sizes may have to be increased for rafter-ceiling joists. Section R806.3. (if applicable) 8. Note on the plans: "Attic ventilation openings shall be covered with corrosion-resistant metal mesh with 1/16" minimum to¼" maximum openings. Section R806.1.(if applicable) 9. The soils engineer recommended that he/she review the foundation excavations. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that: a) The building pad was prepared in accordance with the soils report, b) The utility trenches have been properly backfilled and compacted, and c) The foundation excavations, the soils expansive characteristics and bearing capacity conform to the soils report." 10. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that ii has been determined that the recommendations in the soils report are properly incorporated into the construction documents (see page 6 of the soil report). 11. Note on plans that surface water will drain away from building and show drainage pattern. The grade shall fall a minimum of 6" within the first 10 feet. Section R401.3. 12. Dimension on the plans the 30" clear width required for the water closet compartment and the (minimum) 24" clearance required in front of the water closet. CPC 402.5. 13. Provide a note on the plans: The control valves in showers, tub/showers, bathtubs, and bidets must be pressure balanced or thermostatic mixing valves. CPC Sections 408,409,410. 14. Specify on the plans: Water conserving fixtures: showerheads may not exceed 1.8 GPM of flow. CPC Sections 407, 408, 411, 412. Please revise the note on sheet 1. 15. Specify on the plans whether the existing house was built before or after 1994. For additions or improvements to a residence built before 1994, note on the plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons of water per flush, urinals that use more than one gallon of water per flush, showerheads that have a flow capacity of more than 2.5 gallons of water per minute, and interior faucets that emit more than 2.2 gallons of water per minute) shall be replaced. Certification of compliance shall be given to the building inspector prior to final permit approval. California SB407. 16. Indoor water use. Show compliance with the following table, per CGC Section 4.303.1. FIXTURE FLOW RA TES IShowerheads 1 .8 gpm @ 80 psi 1. Lavatory faucets shall not have a flow rate less than 0.8 gpm at 20 psi. 17. Note on the plans that when a shower is provided with multiple shower heads, the sum of flow to all the heads shall not exceed 1.8 gpm @ 80 psi, or the shower shall be designed so that only one head is on at a time. CGC Section 4.303.1.3.2. 18. Recycling. Note on the plans that a minimum of 65% of construction waste is to be recycled. CGC Section 4.408.1. Please revise the note on sheet 1. 19. All domestic hot water piping to have the following minimum insulation installed: ½" pipe (1/2" insulation);¾" pipe (1" insulation); 1" to 1-½" pipe (1-½" insulation). CPC 609.11 & ES 150.0U) a) Additionally, the ½" hot water pipe to the kitchen sink, and the cold-water pipe within 5' of the water heater both require 1" minimum insulation. ES 150.OU) 20. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 21. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ 22. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Error! Reference source not found. at Es Gil. Thank you. [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: David Yao BUILDING ADDRESS: 1606 James Dr. BUILDING OCCUPANCY: R3 BULDING AREA Valuation PORTION (Sq.Ft.) Multiplier remodel & add Air Corditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordmance • Plan Check Fee b~· Ordinance • Tw:,e ofRe'tt'iew: 1.;; Complete Review r Repetitive Fee "" ····· .., Repeats r· Other r Hourly EBGilFee r r r Comments: Reg. Mod. PLAN CHECK#.: CBR2020-0235 DATE: 2/17/2020 VALUE ($) per city 105,239 105,239 J , 1· Structural Only 1(7$420.@) Sheet of CBR2020-0235 1606 JAMES DR Conroy Addition 1606 James Drive Carlsbad, CA 92008 Structural Calculations -19262 Qualls Engineering Structural Engineering Services CONROY 604 SF ADDITION TO 1 ST & 2ND FLOOR (2BED & 2BATH) // 232 SF COVERED PATIO 1562110900 1/30/2020 CBR2020-0235 GSJor anDesign G egJordan P .. Box.2265 Carlsb d, CA 92018 Phone: 58 775-5169 > 1---0 Qualls Engineering Structural Engineering Services GOVERNING CODE: CONCRETE: REINFORCING STEEL: Project: Conroy Addition Engineer: Andrew Leija DESIGN BASIS 2019 CBC f, = 2,500 psi (MINIMUM) ASTMA615, F, = 60 ksi Sheet: f /t) Job #: _1:.:9c::2:::62::....,__ ILl'f /zo I f Date: SAWN LUMBER: DOUGLAS FIR LARCH, ALLOWABLE STRESS DESIGN P 2016 CBC. ENGINEERED WOOD BOISE CASCADE OR EQUIVALENT BCI WOOD "I' JOISTS -ICC-ESR 1336 BC VERSALAM 2.0E/L VL/LSL -ICC-ESR 1040 PROJECT SCOPE Project consists of a proposed approximately 800 square foot two-story addition to ;an existing two-story single family residence with attached garage located at 1606 James Drive; Carlsbad, CA 92008. The proposed addition and existing residence are primarily constructiod utilizing wood frame construction with 2x stick framed roof and typical slab on grade with rutned down footings. There has not been a soils report provided for this project therefore the foundation design will be based on minimum soils values per 2019 CBC chapter 18. ' Qualls Engineering Structural Engineering Services Design Loads; Pitched Roof: Dead Load ( DL) Roofing 1/2" Plywood Truss Framing Insulation 1/2" Gyp. Bd. Mech./Elcc. Misc. Project: Conroy Addition Engineer: .;;.A;;;Lc.... ___________ _ 5.0 psf 1.8 psf 4.0 psf 0.5 psf 2.2 psf 0.5 psf LO psf 15.0 psf Floor: Dead Load ( DL) Flooring 3/ 4" Plywood Framing Insulation 5/8" Gyp. Bd. Mech./Elec. Misc. Live Load (IL) She t: 2 Job ': 19262 Dab: ----- 9.0 psf 2.3 psf 2.0 psf 0.5 psf 3.0 psf 1.5 psf 1.7 psf 0.0 psf Live Load (LL) LL = ,---,;;20,..0;;,psf (Reducible) DL + LL -I 35.0jpsf LL --_..;:;'"::;·O~psf (Reducible) DL + ll = I 0.0lp,f Walls: Stud Walls Exterior Stud Walls 15.0 psf Interior Stud Walls 7 .0 psf Allowable Soils Bearing Pressure: ASBP = 1,500 psf@ 18 inches below lowest adjacent finished grade Seismic: Site Class: D s, = 1.040 s, = 0.378 I',= 1.200 I',= 1.500 SMS = 1.248 SM,= 0.567 Response Redundancy pCs So,/(R/1) Occupancy Category 11 Importance Mod. Factor Factor Factor,! 1.00 Wind Load: (Simplified Envelope Procedure) Basic Wind 95 mph Exposure: C MWFRS P = 0.6*).. "'Kzt*P530 Q,RFD): P= (ASD): !' =I 17.0 psf 10.Zipsf Component§ & Cladding P = 0.6*A*Kzt*Pnct50 (LRFD): P = (ASD): p =I 20.9 psf 12.s!psf R 6.5 ,=· K.t:::: Ps30:::: Pnet30:::: p 1.3 1.29 10 13.2 16.2 ( LIU•D ) ( ASD ) 0.166 I 0.119 Qualls Engineering \ beet: 2L Structural Engineering Services Project: C.oN/>.-:>y Jbb#: 112..~ z. Engineer: >'\-L. ate: Vertical Design Level: tz~c, 1= D1,= /', psf LR= t.o psf LL= psf Member: ,<tr{ -, w,= 1~ /1~ (,>-tu)• '/7 r1..,f r= ,., ' -W2= t P,= P2= Use: Z)((, ,I' ,, " VlnllX= 2,','f lbs V.n= /Z J /3 lbs IJ RL= i-,f lbs Mmax= -, I I ft-lbs M.u= 11'6 ft-lbs RR= ,, lbs ln,q'd = If'> in4 I= ~ I in• Member: R_g -l ,,,., ' W,= ~,Xtl(/~~1,,o)"" 'l'Z.-oYGF ~ 1 Wz= t P,= ., y/17/!>\/~(. P2= Use: s: I, lie " Vmu= 3~(,0 lbs V,11= ,,~.,, lbs 'I 'I R1, = 3~(eQ lbs Mmax = JJ</'((J ft-lbs M.u-; "' I~ ft-lbs RR= " lbs lreq•d = 18 :1 in4 I= -, ... in' i I Member: ~H -/ I P, W,= "";._ (, n --u,) • Z-8D P'-1~ i ' ~A W2= h-'1t t ( I St '\o) • 1 S"/11,,f' i P,= !l?.(1a,-1). ~ H,",. P2= Use: :'-I XI 6 I, ~· " Vmax = 'J. 7ri lbs V.n= i.-s-z, lbs 'I 'I ' R1, = ,,,.,,-lbs Mmax= 'f'J'I I ft-lbs M.u= (, i) "I ft-lbs RR= ~753 lbs lreq'd -If~ in' I= -i:rl in4 Member: W,= W2= t t P,= P2= Use: I, ,, 'I 'I Vmax = lbs V.n= lbs RL= lbs Mmax= ft-lbs M.n= ft-lbs RR= lbs In,q'd = in4 I= in• Qualls Engineering Structural Engineering Services Vertical Design Level: De= Member: F,-1 .,., ' r= --t ~( l'f,' " I\ Re= rt)'{) lbs " R•= lbs Member: F6-I tf, ... , ----- _, t 'I \3S t L, l z.. ', " 1 'l Re= <;"2.., 7 lbs R•= " lbs Member: f~-.. WI 1) I ~ ::::f::t t ~' \ I, /3 ,, 1 1 Re= />'co lbs R•= "l 'j S:'t lbs Member: 1"B -3 fl)'$' e,.,, ,,,..----t 8 t L, I ;i It 1 'l Re= l'-/v lbs R•= II'/ lbs i heet: j i'. Project: to/\112.<>)'. Jbb#: 1qu,-z.. Engineer: ;11... ate: /:' C<>O ,:,._ -Z..-0 psf LR= 'l--<> psf LL= 'iO psf W,= /i,/t~f1,,()+'(o), 't,Ol'U W,= P,= P,= Use: z_ ~12-<.>K. 11/z "fl Vmax = S"e, D lbs V.u= 7, ,-z...s-. lbs Mmax= 2.-1 D 3 ft-lbs M.u= ;o-r.~ ft-lbs Irui•d = l. 'l in• I= I ~ B Jn4 I W,= 11/i.(t.ot'lo)<b'Yi f1'5f ~ -..'7',._{/J'.f"k>j, ?\-s-1,l{' W,= P1=l'l(I.LOj ~ '!IU )( '!, :J> z,101'1 I P,= Li,..r1. Use: 71' 'r, VS l OIL SXf V max ::::: $;LT7 lbs V.n= ,-lbs Mmax = -ft-lbs M,11= ~i-ft-lbs Ireq'd = -in4 I= -in4 'II<' so· c l"XC.HC.C.. W,= (z.<>tlf•)t 8 'nfffF t (!r-11..o) ~ Z-IS-PL/' W,= P,= ~(H, b.) ~ 'foz ,r 3 "° '2-1 D VJ //, P2= 4..1).. Vmax::::: '2-'fN lbs Mmax= -ft-lbs - Ireq'd = in' W1= '" ft ,_(;.or 'IO) 0 80 (llf' W2= P,= v/.,_(-,_.w.o)~ .i-;,1.. ~. /80# P,= Vmax = / '{(p lbs Mmax::::::: S"T(. ft-lbs lrcq'd = I ?--in4 ! i ' I I (wi111,) Use: 31,)< Fz. vsl V""= lbs M.u= -ft-lbs I= -in4 'I(" JC? l'l1 l X. ""1-U • Use: ;z: l'Z- V.u= ,~ia. Man= ~01 t. I= ,. e O/SL 1¾1t 7\bv(.. <LO ~Q)S lbs ~I ft-lbs in4 I 2-, Qualls Engineering beet: 5 L Structural Engineering Services Project: C CN,._,, y Job#: /9U,z Engineer: I¾--hte: Vertical Design Level: FU><>/L DL= t,-0 psf LR= -z..o psf IL -'i o psf Member: F/1--I ...,, W,= t¼{101-'-1<>)1-91<,~IF f ?'i>ft.(S-V>~!") o/2-'(1,1 lf> r= ---W2= t P1= P2= Use: ~ 1,. >< /j y'b VJ" ~ 8."> v Vmax -S-2-1 (,. lbs V,n= ' ;,, lbs ,, 't RL -I ?.'t I!! lbs Mmax-I I 1-.S-3 ft-lbs M,n= ; it. ls ft-lbs R•= • lbs I"'l•d = I ':t ~ in• I= '1H' in4 Member: EH -i. W,= 11/2-t 2 (zo,'io}t S ·~ 1 t"SF +-1~/t'l-{fffu,) ~~ 13 P r ---.... , --W2= t t P,= P2= Use: ;; '. ,,. II 'Pg Vf'- ~ I l., f v Vmax = lfz,~I, lbs Van= f1lc17 'l 'i juz.,1r lbs Rr, = 'f 2-D (P lbs Mmax = IJ/Y.> ft-lbs M.n= ft-lbs R•= " lbs lreq'd -2 'f.!, in• r-l'fi;t in' I Member: I ' W,= ' W2= I t t P,= ! P2= Use: ,. ,. 1 1 V--lbs Van= lbs RL -lbs M--ft-lbs M,11= ft-lbs R•= lbs Ireqd -in• I= in4 Member: W,= W2= t t P,= Pz= Use: ,. ,. Vmax = lbs 1 1 Vau= lbs R1, = lbs Mma.,i:.= ft-lbs M,n= ft-lbs R.= lbs Ireq'd = in' I= in• Qualls Engineering Project Title: Conroy Addition 4403 Manchester Ave #203 • Encinitas, CA 92024 Tille Block Line 6 ... DESCRIPTION: FB-1 CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set : ASCE 7-10 Material Pro erties Analysis Method : Allowable Stress Design Load Combination ASCE 7-10 Wood Species : Boise Cascade Wood Grade : Versa Lam 2.0 3100 West Engineer: AL Project ID: 19262 Project Descr: Fb+ 3,100.0psi Fb-3,100.0psi Fc-Pnl 3,000.0psi Fc-Perp 750.0psi Fv 285.0psi Fl 1,950.0 psi Beam Bracing : Beam is Fully Braced against lateral-torsional buckling Span = 12.50 ft E: Modulus of Ebend-xx Eminbend- Density Jasticily 2,000.0ksi 1,036.83ksi 41.760pcf lied Loads Service loads entered. Load Factors will b applied for calculations. Beam self weight calculated and added to loads Uniform Load : D = 0.020, L = 0.040 ksf, Tributary Width= 7.50 ft, (FLOOR) Uniform Load : D = 0.0150, Lr= 0.020 ksf, Tributary Width= 11.0 ft, (ROOF) Uniform Load: D = 0.0150 ksf, Tributary Width= 8.0 ft, (WALL) Point Load : E = 2 730 k @4.0 ft, (HOLD DOWN STRAP) DESIGN SUMMARY Maximum Bending Stress Ratio Section used for this span 0.542 1 7x9.5 1,679.01 psi 3,100.00psi +D+L+H Maximum Shear Stress Ratio Section used for this span Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection = = = = 6.250ft Span# 1 0.166 in Ratio= 0.000 in Ratio= 0.466 in Ratio = 0.000 in Ratio= Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Segment Length Span# M V Cd CFN C; c, Cm ,0..+1 Length= 12.50 ft 0.362 0.219 0.90 1.000 1.00 1.00 1.00 ..0"1...+I 1.000 1.00 1.00 1.00 Length = 12.50 ft 0.542 0.327 1.00 1.000 1.00 1.00 1.00 ..0"1.r..+I 1.000 1.00 1.00 1.00 Length= 12.50 ft 0.387 0.234 1.25 1.000 1.00 1.00 1.00 ..0..0.750Lr..0.750L ..+I 1.000 1.00 1.00 1.00 Length= 12.50 ft 0.485 0.293 1.25 1.000 1.00 1.00 1.00 ..0..0.70E..+I 1.000 1.00 1.00 1.00 Length= 12.50 ft 0.301 0.187 1.60 1.000 1.00 1.00 1.00 Load Combination Location of maximum on span Span # where maximum occurs 905>=360 0<360 321 >=240 0<240 C t CL 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1,00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Moment Values M fb 8.87 1,011.22 14.73 1,679.01 13.17 1,500.93 16.49 1,879.34 13.11 1,493.71 • • 1 0.327: 1 7x9.5 = 93.14 psi = 285.00 psi +D+L+H = 11.724 ft = Span# 1 Shear Values F'b V fv F'V 0.00 0.00 0.00 0.00 2790.00 2.49 ~.10 256.50 0.00 0.00 0.00 0.00 3100,00 4.13 93.14 285.00 0.00 0.00 0.00 0.00 3875.00 3.69 83.26 356.25 0.00 0.00 'o.oo 0.00 3875.00 4.62 104.26 356.25 0.00 0.00 0.00 0.00 4960.00 3.79 85.41 456.00 Qualls Engineering 4403 Manchester Ave #203 · Encinitas, CA 92024 Title Block Line 6 ., .. DESCRIPTION: FB-1 Load Combination Segment Lenglh ..0.60D.0.70E..0.60H Span# Max Stmss Ratios M V Lenglh=12.50ft 1 0.226 0.138 Overall Maximum Deflections Load Combination Span <0.0.750Lr..0.750L <ti Vertical Reactions Load Combination eral MAXimum Overall MINimum <O<+i <O<l<+i <O<lr<+i <0,0.750Lr..0.750L<+i <0..0.70E<+i ..0.600..0.70E.0.60H DOnly Lr Only LOnly EOnly Project Title: Conroy Addition Engineer: AL Project ID: 19262 Project Descr: Moment Values Cd CFN Ci Cr Cm Ct CL M lb 1.000 1.00 1.00 1.00 1.00 1.00 1.60 1.000 1.00 1.00 1.00 1.00 1.00 9.83 1,120.50 Max.·-· Defl Location in Span Load Combination 0.4664 6.296 Support notation : Far k>ft ~ #1 Support 1 5. 77 1.856 2.839 4.714 4.214 5.277 4.139 3.003 2.839 1.375 1.875 1.856 Support2 . 7 0.874 2.839 4.714 4.214 5.277 3.451 2.315 2.839 1.375 1.875 0.874 F'b V 0.00 0.00 4960.00 2.79 Max.• • Defl 0. 000 Values in IPS 1 Shear Values fv F'v o.oo 0.00 si.91 456.00 Location in Span 0.000 Qualls Engineenng 4403 Manchester Ave#203 Encinitas, CA 92024 Ti le Block Line 6 I, DESCRIPTION: FB-1 CODE REFERENCES Calculations per NOS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set : ASCE 7-1 O Material Pro ertles Project Title: Conroy Addition Enqineer: AL ProJect ID: 19262 Project Descr: Analysis Method : Allowable Stress Design Load Combination ASCE 7-10 Fb+ Fb- Fc-Prtl Fc-Perp Fv 3,100.0psi 3,100.0 psi 3,000.0psi E : Modulus of lasticity Ebend-xx 2,000.0ksi Eminbend -1,036.83ksi Wood Species : Boise Cascade Wood Grade : Versa Lam 2.0 3100 West Fl Beam Bracing : Beam is Fully Braced against lateral-torsional buckling D 0.12 D 0.165 Lr 0.22 Span= 12.50 ft ~--~----~ 750.0psl 285.0psi 1,950.0 psi Density 41.760pcf A lied Loads Service loads entered. Load Factors will applied for calculations. Beam self weight calculated and added to loads Uniform Load: D = 0.020, L = 0.040 ksf, Tributary Width= 7.50 ft, (FLOOR) Uniform Load: D = 0.0150, Lr= 0.020 ksf, Tributary Width= 1 t.O ft, (ROOF) Uniform Load : D = 0.0150 ksf, Tributary Width= 8.0 ft, (WALL) Point Load: E = 2.730 k@4.0 ft, (HOLD DOWN STRAP) DESIGN SUMMARY Maximum Bending Stress Ratio Section used for this span 0.51l 1 5.25x11.25 1,591.81 psi 3, 100.00psi +O+L -,Ji 6.250ft Span# 1 Maximum Shear Stress Ratio Section used for this span Load Combination Location of maximum on span Span# where maximum oocurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection = 0.133 in Ratio = 0.000 in Ratio= 0.373 in Ratio= 0.000 in Ratio= Maximum Forces & Stresses for Load Combinations Load Combihation Max Stress Ratios Segmant Length Span# M V Cd CFN C1 c, Cm .O+H Length= 12.50 ft 0.343 0.239 0.90 1.000 1.00 1.00 1.00 .O<l+H 1.000 1.00 1.00 1.00 Length= 12.50 ft 0.513 0.358 1.00 1.000 1.00 1.00 1.00 .O<lr+H 1.000 1.00 1.00 1.00 Length= 12.50 ft 0.367 0.256 1.25 1.000 1.00 1.00 1.00 .0+0.750Lr+0.750l +H 1.000 1.00 1.00 1.00 Length= 12.50 ft 0.460 0.320 1.25 1.000 1.00 1.00 1.00 .0+0.70E+H 1.000 1.00 1.00 1.00 Length = 12.50 ft 0.285 0.207 1.60 1.000 1.00 1.00 1.00 Load Combination Location of maximum on span Span # where maximum occurs 1127>=360 0<360 401 >=240 0<240 CI CL 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Moment Values M lb 8.83 956.88 14.69 1,591.81 13.13 1,422.49 16.45 1,782.28 13.07 1,415.84 = = F'b 0.00 2790.00 0.00 3100.00 0.00 3875.00 0.00 3875.00 0.00 4960.00 •- 0.358: 1 5.25x11.25 101.96 psi 285.00 psi +O+L-IH V 0.00 2.41 0.00 4.01 0.00 3.59 0.00 4.49 0.00 3.71 11.588ft Span# 1 Shear Values rv F'v 0.00 0.00 61.29 256.50 0.00 0.00 101.96 285.00 0.00 0.00 91.11 356.25 .0.00 0.00 114.16 356.25 0.00 0.00 94.29 456.00 Qualls·Engineering 4403 Manchester Ave #203 Encinitas, CA 92024 Title Blocl< Line 6 ,. ' DESCRIPTION: FB-1 Load Combination Segment Length Span# -o-0.60D-o-0.70E-o-0.60H Length • 12.50 ft 1 Max Stress Ratios M V 0.214 0.153 Overall Maximum Deflections Load Combination +O-o-0.750Lr-o-0.750L+H Vertical Reactions Load Combination vera I MAXimum Overall MINimum +0-otl +04.+H +04.r-otl +O-o-0.750Lr-o-0.750L +H +D-o-0.70E-otl -o-0,60D-o-0.70E-o-0.60H DOnly Lr Only L Only EOnly Span Project Tttle: Conroy Addition Engineer: AL Project ID: 19262 ProJect Descr: Moment Values Cd CFN C; c, Cm C t CL M fb 1.000 1.00 1.00 1.00 1.00 1.00 1.60 1.000 1.00 1.00 1.00 1.00 1.00 9.81 1,062.96 Max.•.• Dell Location in Span Load Combination 0.3735 6.296 Support nolation : Far left~ #1 Support2 5. 1.856 0.874 2.826 2,826 4.701 4,701 4.201 4.201 5.263 5.263 4.125 3,437 2,995 2.307 2,826 2.826 1.375 1.375 1.875 1.875 1.856 0.874 F'b V 0.00 0.00 4960.00 2.75 Max.· • Defl 0 000 Values In IPS Shear Values fv F'v 0.00 0.00 69.78 456.00 Location in Span 0.000 Qualls Engineering Project Title: Conroy Addition 4403 Manchester Ave #203 -Encinitas, CA 92024 TiUe Block Line 6 I II" DESCRIPTION: FB-2 CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set : ASCE 7-1 O Material Pro erties Analysis Method : Allowable Stress Design Load Combination ASCE 7-10 Wood Species : Boise Cascade Wood Grade : Versa Lam 2.0 3100 West Engineer: AL Project ID: 19262 Project Descr: Fb+ 3,100.0psi Fb-3,100.0psi Fe -Pnl 3,000.0psi Fc-Perp 750.0psi Fv 285.0psi Ft 1,950.0psi Beam Bracing : Beam is Fully Braced against lateral-torsional buckling Span= 13.0 ft E: Modulus of Ebend-xx Eminbend - Density /0 Jasticlty 2,000.0ksi 1,036.83ksi 41.760pcf lied Loads Service loads entered. Load Factors will b applied for calculations. Beam selt weight calculated and added to loads Unttorm Load: D = 0.020, L = 0.040 ksf, Tnbutary Width= 1.0 ft, (FLOOR) Uniform Load: D = 0.0150, Lr= 0.020 ksf, Tributary Width= 1.0 ft, (ROOF) Uniform Load : D = 0.0150 ksf, Tnbutary Width = 8.0 ft, (WALL) Point Load: E = 2.706 k@9.50 ft, (HOLD DOWN STRAP) DESIGN SUMMARY Maximum Bending Stress Ratio Section used for this span 0.348: 1 3.5x9.5 1,728.18psi 4,960.00psi Maximum Shear Stress Ratio Section used for this span Load Combination Location of maximum on span Span# where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection +D+0.70E+H 9.489ft Span# 1 0.318 in Ratio= 0.000 in Ratio= 0.434 in Ratio = 0.000 in Ratio• Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Segment Length Span# M V Cd CFN C1 Cr Cm ..O<H Length= 13.0 ft 0.284 0.166 0.90 1.000 1.00 1.00 1.00 ..O+L<H 1.000 1.00 1.00 1.00 Length= 13.0 ft 0.318 0.186 1.00 1.000 1.00 1.00 1.00 ..O+Lr<H 1.000 1.00 1.00 1.00 Length= 13.0 ft 0.229 0.134 1.25 1.000 1.00 1.00 1.00 ..O-o-0.750Lr-o-0.750L <H 1.000 1.00 1.00 1.00 Length= 13.0 ft 0.261 0.152 1.25 1.000 1.00 1.00 1.00 ..O-o-0.70E<H 1.000 1.00 1.00 1.00 Length= 13.0 ft 0.348 0.230 1.60 1.000 1.00 1.00 1.00 Load Combination Location of maximum on span Span # where maximum occurs 489>=360 0<360 359>=240 0<240 CI CL 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Moment Values M lb 3.48 792.79 4.32 985.39 3.90 889.09 4.43 1,009.47 7.58 1,728.18 • • = 0.230 : 1 3.5x9.5 = 105.09psi = 456.00psi +D+0.70E+H = 12.241 ft = Span# 1 Shear Values F"b V . rv F'v 0.00 0.00 0.00 0.00 2790.00 0.95 42.64 256.50 0.00 0.00 0.00 0.00 3100.00 1.17 ·53.00 285.00 0.00 0.00 0.00 0.00 3875.00 1.06 47.82 356.25 0.00 0.00 0.00 0.00 3875.00 · 1.20 54.29 356.25 0.00; 0.00 '0.00 0.00 4960.00 2.33 165.09 456.00 Qualls Engineering 4403 Manchester Ave #203 . Encinitas, CA 92024 Title Block Line 6 DESCRIPTION: FB-2 Max Stress Ratios Load Combination Segment Length Span# M V <-0.60D<-0.70E<-0.60H Length= 13.0 ft 1 0.298 0.193 Overall Maximum Deflections Load Combination +D<-0.70E<tl Vertical Reactions Load Combination e I AXimum Overall M!Nimum +D<tl +D+l<tl +D+lr<H +D<-0.750Lr<-0 .750L <ti .0<-0.70E<tl <-0.60D<-0.70E<-0.60H DOn~ Lr On~ LOn~ EOnly Span 1.000 1.60 1.000 1.00 1.00 1.00 1.00 Max. •. • Defl Location In Span 0.4341 6.680 Project Title: Conroy Addition Engineer: AL Project ID: 19262 ProJect Descr: Moment Values M lb 1.00 1.00 1.00 1.00 1.00 1.00 6.48 1,478.12 Load Combination Support notation : Far left~ #1 Support 1 .5 0.729 1.070 1.330 1.200 1.363 1.580 1.152 1.070 0.130 0.260 0.729 Support2 .5 1.977 1.070 1.330 1.200 1.363 2.454 2.026 1.070 0.130 0.260 1.977 F'b 0.00 4960.00 I ( Shear Values V Iv F~ 0.00 0.00 0.00 1.95 86.03 456.00 Max." "Defl Location In Span 0 000 Values in IPS 0.000 Qualls Engineering Structural Engineering Services Level Component Weight (psi) Main Roof 15 Roof Deck ·: ,15:. Roof Exterior Wall 15 Interior Wall 7 Main Floor 20 Floor Deck !$ 2nd Floor Exterior Wall 15 Interior Wall 7 C, (ASD) W (lbs) V (lbs) 0.119 76,252 9,063 Level w. (kips) h,. (ft) Roof 26.4 17 2nd Floor 49.9 8 L: c, h,. X 0.02 17 0.75 Ps 10.2 North-South Level Height (ft) Diaphragm Dcnth /ft\ Roof Peak · 21 ' Roof 17 50 2nd Floor 8 50 ~, Direction Governing Load North-South Seismic I 6.4 nsf East-West Sefamic 1 6.4 osf Project: Contoy Addition Engineer: AL Lateral Analysis Tribuhl"' Arca fft:t; Tributary Tributary Weight IWeight Length (ft) Height (ft) (lbs) (lbs) ·,. --tA8Q 17.700 .. .. 0 0 y,.j_ 13.365 26,399 9.0 . '· 64,. 9.0 4,032 ·,•j;j \lj/'" · .. 23600 . 6 l .. 10.215 49,854 -,' ·_99,. ,"• 8.0 11.880 : ... !ro 8.0 2,800 ,:, 76,252 w,1,,.•(k-ft) :1¥..!!.". v. (lbs) A<ea(ft) v. (psi) Z:(W.h,. ', 449 0.53 4 799 1180 4.1 399 0.47 4,265 1,861 2.3 848 ,:, 6.4 k 0.17 1.0 Wind Check . East-West v. (psi) Level Diaphnlgm Height (ft) Deoth /ft\ Roof Peak 21 . 1.7 Roof 17 28 1.7 2nd F'.loor 8 45 3.5 L: Sheet Job#: Date: v. (p, f) 3.1 1.9 5,01 t 2.. 19262 Qualls Engineering Structural Engineering Services Project: Conroy Addition Engineer: -=-AL=--------- Lateral Design Direction Controlling Load I North-South I Seismic l V Dlract VDlrectly V OffHt V Level v. (paf) Grid Trib Area (fti Cumulative (lbs) Above(lba) Above(lbs) ,, .. , A 0 0 Roof 4.1 B 2.399 -2399 2 399 -2 399 ' •c•:· 781 0 0 781 2nd Floor 2.3 . 936· 2143 2399 4542 . \" ' 896 0 . 896 ·• 1 031 3430 N,..._.,.oh Woll • Level Grld "'"" "'" ""'' ., .. , ""' "'"'' """ ., ... Tow ..,....,_ A -' ._._,, ,,, . ·.• 0 0 Roof El C&D II ·. " II , .. .. . . · CT 7.S 1.S A -,;'.' . " 0 ""'"""' • C .. . • .. S.2S 5.25 0 0 D U,5 ll.5 11.S Overturning Anal)"'i• l'ii;'(ij1 B.Qoft, . ' 12nd Floorl • Nottb.SOUth L,.mln (ft) M.,.(ft-1"-) RoofTrib(I\) FloorTr!b(ft) Add'l M,.,. (ft.tba) M.,.(ft-lbo} C(h) A 0 ..,,, B n C&D 7.S A 0 B "' ,., C 0 D 11,5 "' "' '" 0 "' #N/A, 19,194 0 l9194 19194 " "-"' #N/A 46,638 0 0 0 .. ' 1 1745 l M ''" '-"' .. 0 0 IO ·t _. .M "'' (r,_')21 " 0 ' ,;,,, . .. 13,.355 ♦,055 :·hcet: Job#: 19262 )ate: . h:2W SWT DNO '" ,1,M 6B "" 1.00 .. • .., ,. '"' #Drv OI "' 1.00 " T ) HD "-,;,lty(lbo) OCR "-000 000 " MSTOO "'' 0.47 .. MSTC52 ~45.'> 0.68 N-"' MO ,n HDU, ""' 0.82 N= 000 0.00 HOU• 4,565 0.70 Qualls Engineering heet: I 'l (_ Structural Engineering Services Project: Conrox Addition J,ob#: 19262 Engineer: AL )ate: ' Lateral Design ' Direction Conltolllng Loa• I East-West I Seismic I V Dln>et VDlrectly VOffHt V Level v,. (pt,f) Grid Trtb Area (1'12} Cumulative (lbs) Above(lbs) Above(lbt) 'lbs' " I 915 . 915 Roof 4.1 . .• . . , 2399 . 2399 4 1594 -1594 ' 51• 915 0 1431 2.3 . ., ,•,.,,, 1352 2 399 . 3751 2nd Floor '4·, 1,,;"i 781 1 . · ',' . 2376 .. 1880 0 1680 &ut-Wnt w • ...., Gd< w .. , W.U2 "'"'' w ... w .. , w .. , "'"" ""'' Tow Ml...,_ . h:2w ... . ·.· ' ,, .. ,. s .,, "' <M 6R Roof ,., ._ .,_5 .. ~ ,, s.s s.s "' 1.00 >E • . .. ',, ,r:, •. •t'.'.,.'' 0 0 #DIV/01 1 .. ,,: ,,· . 6.75 325 "' 1 68 ""''""" ,., ' -,,~ -,-_, ; " s, ,., 1.00 ,n 4 .,. 0 0 #DTVOI , .. , .. ,' 0 0 #DlVOI Overturning Analysis ~ 1&1W.U~~f)1lntWaU~..t~11loof°;t!t:!}IPb>rD:1~1 8 Eu~We.i L.mln(l't) . Add'I M., (ft-lbl) M...(fl-tbs) RoofTrlb 'ft' PJoorTrlb rt Add'IM-1!l-llM) .,_, .... c,,,. T JIM\ HD c,, DCR 1 6.7S "' ""' ' ,.., I M I 920 .., Roof .., " "' 19,llM 8 -,-,, 64''" ,,,. '·"" ]· 2r, MS><" 3,455 0,0 • 0 0 0 . 0 0 0 No~ 000 000 1 .75 "' ' 18764 I ,.,. .. 7_137 2,780 ' HDU2 l,o75 . ., .., s.s "' 191<,M 31.1191 "" • .M 1214 '"' s HDUS s s 1.00 '"" 4 0 0 ' 0 0 0 0 N•~ 000 0.00 ... 0 0 A #NIA 0 0 0 N-600 I ' ! • Qualls Engineering i Sheet: l S:: Structural Engineering Services Project: . Job#: I 'tUe'2. . Engineer: Date: FOUNDATION DESIGN AUowable Soils Bearing Capacity Foundation design 1,500 psf b = 15 d = 18 15 18 2#4 inch wide x' inch deep £ oting with topandbo om Allowable Max Line Load W m" = b X ASBP Allowable Max Point Load Pm.,= b x2dxASBP Spread Footing Design = 1,875 plf = 5,625 lbs Pm"= b2 xASBP F2= 2 foot square footing with 3 # 4 each way@ btm pmax = 6,000 lbs F2.5 = 2.5 foot square footing with 3 # 4 each way@ btm Pmax = 9,375 lbs F3= 3 foot square footing with 4 # 4 each way @ btm p = =x 13,500 lbs F3 .. 5 = 3.5 foot square footing with 4 # 4 each way@ btm Pmax;:::: 18,375 lbs F4= 4 foot square footing with 5 # 4 each way @ btm Pmax = 24,000 lbs FS= 5 foot square footing with 6 # 4 each way@ btm p = m.. 37,500 lbs MAR 11 2020 (_ City of Carlsbad CERTIFICATION OF SCHOOL FEES PAID This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City prior to issuing a building permit. The City will not issue any building permit without a completed school fee form. Project# & Name: Permit #: CBR2020-0235 ===c..::.='-------------- P r o j e ct Address: 1606 JAMES DR ------------------- Assessor's Parcel #: 1562110900 ====.c_ _____________ _ Project Applicant: TRUST CONROY FAMILY REVOCABLE TRUST 09-29-15 (Owner Name) Residential Square Feet: New/Additions: ::.60::.4-'-------------------- Second Dwelling Unit: _________________ _ Commercial Square Feet: New/Additions: ------------------- City Certification: City of Carlsbad Building Division Date: 03/09/2020 Certification of Applicant/owners. The person executing this declaration ("Owner'') certifies under penalty of perjury that (1) the information provided above is correct and true to the best of the Owner's knowledge, and that the Owner will file an amended certification of payment and pay the additional fee if Owner requests an increase in the number of dwelling units or square footage after the building permit is issued or if the initial determination of units or square footage is found to be incorrect, and that (2) the Owner is the owner/developer of the above described P. · c ), or that the person executing this declaration is authorized to sign on behalf of th Own I "ij Carlsbad Unified School District 6225 El Camino Real Carlsbad CA 92009 Phone: (760) 331-5000 [;;:,;:! Encinitas Union School District 101 South Rancho Santa Fe Rd Encinitas, CA 92024 Phone: (760) 944-4300 x1166 I'./;:! San Dieguito Union H.S. District 684 Requeza Dr. Encinitas, CA 92024 Phone: (760) 753-6491 Ext 5514 (By Appl. Only) ! > :j San Marcos Unified Sch. District 255 Pico Ave Ste. 100 San Marcos, CA 92069 Phone (760) 290-2649 Contact: Katherine Marcelja (By Appl.only) I )] Vista Unified School District 1234 Arcadia Drive Vista CA 92083 Phone (760) 726-2170 x2222 SCHOOL D STRICT SCHOOL FEE CERTIFICATION (To be completed by the school district(s)) THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE PROJECT HAVE BEEN OR WILL BE SATISFIED. The undersigned, being duly authorized by the applicable School District, certifies that the developer, builder, or owner has satisfied the obligation for school facilities. This is to certify that the applicant listed on page 1 has paid all amounts or completed other applicable school mitigation determined by the School District. The City may issue building permits for this project. Signature of Authorized School District Official: Qr Chuvcnlll Ctwutw) Date 2,/( \ ( 2-D Title S.\.)p.U lITT:Q h c,U V\+ Name of School District: __ .::;,,;,AR~.Ll=JSB--l'A'IIDMU!MNl~FI ... ED.,_,s.._c_H_O_OL_D_IS_T_R_lC_T ___ Phone 1 (p O -3 3 ( -5' DD 0 -C?.25 EL CAMINO REAL Community & Economic D~~CA 82ll1'8ing Division 1635 Faraday Avenue I Carlsbad, CA 92008 I 760-602-2719 I 760-602-8558 fax I building@carlsbadca.gov Brian Conroy EAST COUNTY SOIL CONSlJLTA TION Al\'D ENGINEERING, INC. 10925 HARTLEY ROAD. SUITE '"I" SANTEE, CALffORNIA 92071 TEL. (619) 258-7901 1606 James Drive Carlsbad, California 92008 Subject: Review of foundation Drawings, Plans and Details for Proposed Two-Story Addition 1606 James Drive Carlsbad, California 92008 February 25, 2020 Project No. 20-1106F4 Reference "Geotechnical Investigation for Proposed Two-Story Addition, Proposed Two- Story Addition, I 606 James Drive, Carlsbad, California 92008", Project No. 20- 1106F4, Prepared by East County Soil Consultation and Engineering, Inc, Dated January 17, 2020 Dear \1r. Conroy. In accordance with your request, we have reviewed the foundation drawings, plans and details prepared by G.S. Jordon Designs of Carlsbad. California and Qualls Engineering of Encinitas, California for the proposed two-story addition at the subject site. The foundation plan and details were found to be in accordance with the recommendations presented in the referenced geotechnical report. Our firm should observe the foundation excavations for proper size and embedment into competent bearing soils. If we can be of fort her assistance, please do not hesitate to contact our office Respectfolly Submitted, Martin R. Owen, PE. GF Geotechnical Engineer FEB 2 6 2020 STORM WATER POLLUTION PREVENTION NOTES 1. ALL NECESSARY EQUIPMENT AND MAlERIALS SHALL BE AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATlON OF EROSION AND SEDIMENT CONTROL BMPs WHEN RAIN IS EMINENT. 2. lHE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF Tl1E CITY INSPECTOR AFTER EACH RUN-OFF PRODUCING RAINFALL. 3. THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY lliE CITY INSPECTOR DUE TO INCOMPLETE GRADING OPERA TlONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 4. ALL REMOVABLE PROTECllVE DEVICES SHALL BE IN PLACE AT TI-IE END OF EACH WORKING DAY v.1--IEN THE FIVE (5) DAY RAIN PROBABILJTY FORECAST EXCEEDS FORTY PE CENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL 5. ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM AGGREGATE. 6. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER PROTECTION BEST t.4ANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINED. 7. THE CITY INSPECTOR SHALL HAVE TI--IE AUTHORITY TO ALTER THIS PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED TO ENSURE COMPLIANCE ~TH CITY STORM WATER QUALITY REGULATIONS. OWNER'S CERTIFICATE: I UNDERSTAND AND ACKNO'M.EDGE THAT I t.4UST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION ACTIIJlTIES TO THE t.4AXlt.4Ut.4 EXTENT PRACTICABLE TO AVOID THE MOBILIZATION Of POU.UTANTS SUCH AS SEDIMENT AND TO AVOID THE EXPOSURE Of STORM WATER TO CONSTRUCTION RELATED POLLUTANTS; AND (2) ADHERE TO, AND AT AU TIMES, COMPLY WITH THIS CITY APPROVED TIER 1 CONSTRUCTION S'M"PP THROUGHOUT THE DURATION OF THE CONS1RUCTION ACTl\JlTIES UNTIL THE CONSTRUCTION 'NORK IS COMPLETE AND APPROVED BYTHC~l20! ---·-~ OWNER(S)/O'ffl'.IER'S AGI OWNER(S)/OWNER S AGENT NAME (SIGNATURE) E-29 om STORM WATER COMPLIANCE FORM TIER 1 CONSTRUCTION SWPPP E-29 ~2J2Fo2.o5 SW BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE Best Management Practice* (BMP) Description ➔ CASQA Desigl'llllion ➔ Construction Activity Grading/Son Disturbance Trench ing/[xcovation StockpH'1g Drilling/Boring Concrete/Asphalt Sawcutting f_l Concrete Flatwan< Paving Conduit i e Installation Stucco ortar Work Waste Disposal Staging/Lay Down Area Equipment Maintenance and Fuelina Hazardous Substa'l_CJ!' \.)se/Storage Dewatering Site Access Across Dirt Other (list): Instructions: ~ ~ Erosion Control '""' ~. o• .£ ~(/) ·o :::i n 8, a Sediment Cootrot BMPs ~ 0 Trackir,g ControtBMPs 0 O ,g ,g .., 2 2 5.~.!!~ ~ .. ~ ;g_ CDfr~c 8~8 11 ~ ~ i ~ I l-~~ l§ -g~il> ~.~ti':]]~cgf~ ~~it woltnl I~ Ji B ~ ~ e,;g ~ in£ ~g' r;;& I ~ii C I ~i i ~lwl ~ 1-~ ~ ~ ~ -1~1~1~1~ J.. ,:., J.. J.. J.. (/) (/) (/) (/) (/) 0 1• ~ :,: w ' I>! 0 ' I>! l N ' ~ Non--Stoml Water Management BMPs ' I '. i] ~ ~ '5 8 ]§ c,,.:. -~ i ~o ~ ~ ,g 1 • il, E l ·! . ~ 0 ii ~1;.~1 0 .!.! g ~ ia ~ ' !Q w ' !Q 6 f ~ :§ 8, .0 o.2 ~~ r~ ' ii Waste Management and Matenals PollL!lioo Control BMPs . ~ E o • 0 ., I _g • ~ 0 = ~ ! ] I~~ ~ in Jt8 ~-1~· i ~ 5 ~ CJ' 1' CJ' :5! g 2 g 0 O o O Vl :::::E :C: :::::E Nini• ~~J ~ I I I I I i i i i i 1. Check the box to the left of all applicable construction activity (first column) expected to occur during constructioo. 2. Located along the top of the BMP Table is a list of BMP's with it's corresponding California Stormwoter Quality Association (CASQA) designation number. or more B~Ps you intend to use during construction from the list. Check the box where the chosen activity row intersects with the BMP column. Choose one 3. Refer to the CASQA construction handbook for information and details of the chosen BMPs and ho"" to apply them lo the project. SHOW THE LOCA T/ONS OF ALL CHOSEN BMPs ABOVE ON THE PROJECTS SITE Pl.AN/EROSION CONTROL Pl.AN. SEE THE REVERSE SIDE OF THIS SHEET FOR A SAMPLE EROSION CONTROL Pl.AN. -BM P's are subject to field inspection- PROJECT~ON - Site Addres:.k.t2ik :<-:.,~-.pf2 l Assessor's Parcel NumbeJq;.,-Z..Jf :Cf(-0: Emergency Contact: Nome: _____________ _ 24 Hour Phone: __________ _ Construction Threet to Storm Water Quality (Check Box) 0 MEDIUM ~ LOW ].., ., . _:,!~ ~ g' l5 a U:::::E ,,-~ a:> t'"\ ,. ~ ~· :, ,, Page 1 of 1 ' REV 02/16 DETERMINATION OF Develoe_ment Services (city of PROJECT'S SWPPP Land Development Engineering TIER LEVEL AND CONSTRUCTION 1635 Faraday Avenue 760-602-2750 Carlsbad THREAT LEVEL www.carlsbadca.gov E-32 I'm applying for: ~ in9 Permit;) n.Building Permit □ Right-of-way permit □ Other Project Name:rr,t »->< 1:1r11 IV >roject ID: DWG #/CB# Address: 11,~li-,, .'v ~" P'.fZ-, APN 11.I..:,-Uj~c,q-CDJisturbed Area: ,o I Ac (+fO~F) ~ Section 1: Determination of Project's SWPPP Tier Level SWPPP (Check annlicable criteria and circle the corresoondina SWPPP Tier Level, then ao to section 2) Tier Level Exem!/t -No Threat Project Assessment Criteria My project is in a category of permit types exempt from City Construction SWPPP requirements. Provided no significant grading proposed, pursuant to Table1, section 3.2.2 of Storm Water Standards, the followina oermits are exemot from SWPPP renuirements: Exempt ), Electrical ), Patio ), Mobile Home ), Plumbing ), Spa (Factory-Made) ), Fire Sprinkler ), Mechanical ), Re-Roofing ), Sign ), Roof-Mounted Solar Array .................. ............. . ......................... ··············••·•···· ............................ ...........• . .................. . ..............•. Tier 3-Significant Threat Assessment Criteria -(See Construction General Permit (CGP) Section I.B)* □ My project includes construction or demolition activity that results in a land disturbance of equal to or □ greater than one acre including but not limited to clearing, grading, grubbing or excavation; or, My project includes construction activity that results in land disturbance of less than one acre but the construction activity is part of a larger common plan of development or the sale of one or more acres of disturbed land surface or, □ My Project is associated with construction activity related to residential, commercial, or industrial Tier 3 development on lands currently used for agriculture; or □ My project is associated with construction activity associated with Linear Underground/overhead Projects (LUP) including but not limited to those activities necessary for installation of underground and overhead linear facilities (e.g. conduits, substructures, pipelines, towers, poles, cables, wire, towers, poles, cables, wires, connectors, switching, regulating and transforming equipment and associated ancillary facilities) and include but not limited to underground utility mark out, potholing, concrete and asphalt cutting and removal, trenching, excavation, boring and drilling, access road, tower footings/foundation, pavement repair or replacement, stockpile/borrow locations. □ Other oer CGP Tier 2-Moderate Threat Assessment Criteria: My project does not meet any of the Significant Threat Assessment Criteria described above and meets one or more of the following criteria: □ Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code); or, □ Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas and project meets one or more of the additional following criteria: Tier 2 • located within 200 feet of an environmentally sensitive area or the Pacific Ocean; and/or, • disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical; and/or • disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse; and/or • construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 throuah Apr. 30). \ril!r 1-Low Threat Assessment Criteria ~y project does not meet any of the Significant or Moderate Threat criteria above, is not an exempt ermit type per above and the project meets one or more of the following criteria: Tier 1 • results in some soil disturbance; and/or • includes outdoor construction activities (such as roof framing, saw cutting, equipment washing, material stockoilina, vehicle fuelina, waste stockpilina) " Items listed are excerpt from CGP. CGP governs criteria for tnggers for Tier 3 SWPPP. Developer/owner shall confirm coverage under the current CGP and any amendments, revisions and reissuance thereof. SWPPP Section 2: Determination of Project's Construction Threat Level Tier (Check applicable criteria under the Tier Level as determined in section 1, circle Construction Level the corresponding Construction Threat Level, then complete the Threat Level sianature block below) Exempt -Not Applicable -Exempt Tier 3 -High Construction Threat Assessment Criteria: Mt Project meets one or more of the following: □ Project site is 50 acres or more and grading will occur during the rainy season □ Project site is located within the Buena Vista or Agua Hedionda Lagoon watershed, inside or within 200 feet of an environmentally sensitive area (ESA) or discharges directly to an ESA High □ Soil at site is moderately to highly erosive (defined as having a predominance of soils Tiera with USDA-NRCS Erosion factors kf greater than or equal to 0.4) □ Site slope is 5 to 1 or steeper □ Construction is initiated during the rainy season or will extend into the rainy season (Oct. 1 -April 30). □ Owner/contractor received a Storm Water Notice of Violation within past two years Tier 3 -Medium Construction Threat Assessment Criteria Medium □ All projects not meeting Tier 3 High Construction Threat Assessment Criteria Tier 2 High Construction Threat Assessment Criteria: Mt Project meets one or more of the following: □ Project is located within the Buena Vista or Agua Hedionda Lagoon watershed, inside or within 200 feet of an environmentally sensitive area (ESA) or discharges directly to an ESA □ Soil at site is moderately to highly erosive (defined as having a predominance of soils High with USDA-NRCS Erosion factors k, greater than or equal to 0.4) Tier 2 □ Site slope is 5 to 1 or steeper □ Construction is initiated during the rainy season or will extend into the rainy season (Oct. 1-Apr. 30). □ Owner/contractor received a Storm Water Notice of Violation within past two years □ Site results in 10,000 sq. ft. or more of soil disturbance Tier 2 -Medium Construction Threat Assessment Criteria Medium □ My project does not meet Tier 2 High Threat Assessment Criteria listed above Tier 1 -Medium Construction Threat Assessment Criteria: Mt Project meets one or more of the following: □ Owner/contractor received a Storm Water Notice of Violation within past two years Medium □ Site results in 500 sq. ft. or more of soil disturbance Tier 1 □ Construction will be initiated during the rainy season or will extend into the rainy season (Oct.1-April 30) Tier 1 -Low Construction Threat Assessment Criteria Low ~ My project does not meet Tier 1 Medium Threat Assessment Criteria listed above I certif to the be'st of m knowled e that the above statements are true and correct. I will repare and submit an appropriate tier level SWPPP as determined above y y g p prepared in accordance with the City SWPPP Manual. I understand and acknowledge that I must adhere to and comply with the storm water best management practices pursuant to Title 15 of the Carlsbad Municipal Code and to City Standards at all times during construction activities for the permit type(s) checked above. The City Engineer/Building Official may authorize minor variances from the Construction Threat Assessment Criteria in special circumstances where it can be shown that a lesser or higher SWPPP Tier Level is warranted. City Concurrence: Yes No (For City Use Only) By: Date: Project ID: E-32 Page 2 of 2 Rev. 2/16/16 (city of Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of permits are not required to fill out this form ❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) 1 ❖ Pool ..i If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. ..i Details on CAP ordinance requirements are available on the city's website . ..i A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and download the latest form. Project Name/Building Permit No.: Property Address/APN: Applicant Name/Co.: Applicant Address: Contact Phone: Contact Email: Contact information of person completing this checklist (if different than above): Name: Company name/address: B-50 Contact Phone: Contact Email: Page 1 of 6 Revised 08/19 -•\,, ...... -•••II ...... ...., ........... _ .. , •• ....._._...,I ,...,. .......... I ........ • ...,..., .............. ._,. ....... , -• • ._,....,,...,.._. .. Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For alterations and additions to existing buildings, attach Building Permit Valuation worksheet. Building Permit Valuation (BPV) from worksheet:$ ! D 5 2, ~0\- ~ Residential □ New construction . -\)g_ Additions and alterations: □ BPV < $60,000 1:-BPV " $60,000 ( □ Electrical service panel upgrade only □ BPV" $200,000 D Nonresidential □ New construction □ Alterations: □ BPV" $200,000 or additions" 1,000 square feet □ BPV" $1,000,000 □ "2,000 sq. ft. new roof addition 1. Energy Efficiency A high-rise residential building is 4.or more stories, including a Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor area is residential use 2A, 3A, 1B, 2B, 4A 3B,4A rl'llA N/A All residential additions and alterations ,, 1-2 family dwellings and townhouses with attached garages 1A, 4A ~ 4A only •Multi-family dwellings only where interior finishes are removed 1A, 4A' 1 B, 4A' and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed 1 B, 2B, 3B, 4B and 5 1B, 5 1B,2B,5 Building alterations of" 75% existing gross floor area 2B, 5 1 B also applies if BPV" $200,000 Please refer to Carlsbad Municipal Code (CMG) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CALGreen) for more inf rmation when completing this section. See CMC se ,on 18.30.190. □ Exception: Home energy score~ 7 (attach certification) Year Built □ Before 1978 □ 1978 and later etween 1978 and 1991 □ 1992 and later Single-family Requirements Multi-family Requirements Select one: □ Duct sealin □ Attic insulation □ Cool roof □ Attic insulation Select one: □ Lighting package □ Water heating Package Select one: □ Duct sealin Select one: □ Lighting package B. D Nonresidential• new construction or alterations? $200,000 building permit valuation, or additions ? 1,000 square feet. □ N/A l lmfritt->d R/1-=i/?OJ() ·c insulation □ Cool roof □ Water heating package See CMC 18.21.155 and CALGreen Appendix AS, Division A5.2-Energy Efficiency. A5203.1.1 Choose one: □ .1 Outdoor lighting □ .2 Warehouse dock seal doors □ .3 Restaurant service water heating (comply with California Energy Code section 140.5, as amended) □ NIA _________ _ □ .4 Daylight design PAFs □ .5 Exhaust air heat recovery A5203.1.2.1 Choose one as applicable: □ .95 Energy budget □ .90 Energy budget □ N/A A5211.1tt □ On-srte renewable energy □ N/A A5211.3tt □ Green power (if offered by local utility provider, 50% minimum renewable sources) □ NIA A5.212.1 □ Elevators and escalators □ N/A A5.213.1 □ Steel framing □ N/A 'Includes hotels/motels and high-rise residential buildings tt For alterations~ $1,000,000 BPV and affecting > 75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply with CMG 18.30.130 instead. 2. Photovoltaic Systems A. D Residential new construction (for low-rise residential building permit applications submitted after 111120). Refer to 2019 California Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic requirement (28 below) instead. 2) If project includes installation of an electric heat pump water heater pursuant to CMC 18.30.150(8) (high-rise residential) or 18.30.170(8) (low-rise residential), increase system size by .3kWdc if PV offset option is selected. Floor Plan ID (use additional CFA #d.u. Calculated kWdc' sheets if necessary) Total System Size: k\Ndc = (CFAx.572) I 1,000 + (1.15 x#d.u.) 'Fomnula calculation where CFA = conditional floor area, #du= number of dwellings per plan type If proposed system size is less than calculated size, please explain. Exception □ □ □ □ k\Ndc 8. D Nonresidential new construction or alterations ~$1,000,000 8PV and affecting ~75% existing floor area, or addition that increases roof area by ~2,000 square feet. Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to high-rise residential and hotel/motel buildings. Choose one of the following methods: □ Gross Floor Area (GFA) Method GFA: □If< 10,000s.f. Enter: 5 kWdc Min. System Size: □ Ill! 10,000s.f. calculate: 15 kWdc x (GFA/10,000) •• kWdc "Round building size factor to nearest tenth, and round system size to nearest whole number. □ Time-Dependent Valuation Method I Jnc'hit~d R/l";/J01() Annual TDV Energy use: .. • ______ x .80= Min. system size: _____ kWdc ... Attach calculation documentation using modeling software approved by the California Energy Commission. 3. Water Heating A. D Residential and hotel/motel new construction Please refer to CMC sections 18.30.150 and 18.30.170 when completing this section. □ For systems serving individual dwelling units choose one: □ Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) □ Heat pump water heater AND PV system .3 kWdc larger than required in CMG section 18. 30.130 (high rise residential hotel/motel) or CA Energy Code section 150.1(c) 14 (low-rise residential) □ Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher □ Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors □ Exception: □ For systems serving multiple dwelling units, install a central water-heating system with all of the following: □ Gas or propane water heating system □ Recirculation system per CMG 18.30.150(8) (high-rise residential, hotel/motel) or CMG 18.30.170(8) (low- rise residential) □ Solar water heating system that is either: □ .20 solar savings fraction □ .15 solar savings fraction, plus drain water heat recovery □ Exception: B. D Nonresidential new construction Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section. □ Water heating system derives at least 40% of its energy from one of the following (attach documentation): □ Solar-thermal □ Photovoltaics □ Recovered energy □ Water heating system is (choose one): □ Heat pump water heater □ Electric resistance water heater(s) □Solar water heating system with .40 solar savings fraction □ Exception: 4 _,,., ..... , _._.., ,._,,_,,...._. -Ill I,,._.,_.,_,• 1.....-LI ..... I I I ,,..., I _.._., ,._,,._,,..,_,, ,.._., -• ,.,_,.,_,,..,.._,,_ esidential New construction and major alterations• lease refer to Carlsbad Ordinance CMC section 18.21.140 when com letin this section. One and two-family residential dwelling or townhouse with attached garage: One EVSE Ready parking space required D Exception : □ Multi-family residential· □ Exception · Total Parl<ing Spaces EVSE Soaces Proposed Caoable Readv Installed Calculations: Total EVSE spaces= .10 x Total parking (rounded up to nearest whole number) EVSE Installed= Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other= Total EVSE spaces-EVSE Installed (EVSE other may be "Capable," "Ready" or "Installed.") Total 'Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation~ $60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), alterations have a building permit valuation~ $200,000, intenor finishes are removed and significant site work and upgrades to structural and mechanical, electncal, and/or plumbing systems are proposed. B D Nonresidential new construction (includes hotels/motels) □ Exception · Total Parl<ing Spaces EVSE Soaces Proposed Capable Ready Installed Total Calculation· Refer to the table below· Total Number of Parkinq Spaces provided Number of required EV Spaces Number of required EVSE Installed Spaces □ 0-9 1 1 □ 10-25 2 1 □ 26-50 4 2 □ 51-75 6 3 □ 76-100 9 5 □ 101-150 12 6 □ 151-200 17 9 □ 201 and over 10 percent of total 50 oercent of Required EV Spaces llnrh1tt~rl R/l'i/?019 5. 0 Transportation Demand Management (TDM): Nonresidential ONLY An approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT. City staff will use the table below based on your submitted plans to determine whether or nor your permit requires a TOM plan. If TOM is applicable to your pennit, staff will contact the applicant to develop a site-specific TOM plan based on the pennit details. Acknowledgment: Employee ADT Estimation for Various Commercial Uses Use Office (all), Restaurant Retail3 Industrial Manufacturing Warehousin EmpADTfor first 1,000 s.f. 20 11 8 4 4 4 EmpADTI 1000 s.f., 13 11 4.5 3.5 3 1 1 Unless otherwise noted, rates estimated from /TE Trip Generation Manual, 10thEdition , For all office uses, use SAN DAG rate of 20 ADTl1,000 sf to calculate employee ADT , Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration Sample calculations: Office: 20,450 sf 1. 20,450 sf I 1000 x 20 = 409 Employee ADT Retail: 9,334 sf 1. First 1,000 sf= 8 ADT 2. 9,334 sf -1,000 sf= 8,334 sf 3. 8,334 sf/ 1,000 x 4.5 + 8 = 46 Em lo ee ADT I acknowl my permit ed may be nderstand t to the City of Carlsba ' sportation Demand Management Ordinance. I agree to be contacted should an is a condrtion of permit issuance. Applicant Date: Person other than Applic nt to be contacted for TDM compliance /if applicable): Name (Pnnted): ___________________ _ Phone Number: _____ _ Email Address: ___________________ _ l lmhitPcl R/1-=i/?01 C) Ii 1..E:TTE:~ OF AUTHO~IZATION JAN 3 O 2020 I, BRIAN CONROY, AS Ol/l!NE:R OF THE: PROPERTY L.OCATE:D AT 1 606 JAMES DRIVE: IN CARL.SSAD CA, 'i :2008; DO HERESY AUTHORIZE: (5,R!:(5, JORDAN (gsjordsndesign) TO ACT ON MY SE:HAL.F FOR PURPOSES FIL.ING, AN APPL.ICATION FOR SUIL.DING, PERMIT FOR THE: PROPOSED ADDTION TO MY HOME: L.OCATE:D AT THE: ABOVE: MENTIONED L.OCATION. (Homeo ner)