Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
267 CHINQUAPIN AVE; ; CBRA2020-0192; Permit
Building Permit Finaled (city of Carlsbad Residential Associated Permit Print Date: 09/30/2021 Permit No: CBRA2020-0192 Job Address: 267 CHINQUAPIN AVE, CARLSBAD, CA 92008-7410 Status: Closed -Finaled Permit Type: BLDG-Associated Permit Residential 2060803800 Work Class: Second Dwelling Unit Parcel#: Valuation: $98,043.39 Occupancy Group: #of Dwelling Units: 1 Bedrooms: Bathrooms: Occupant Load: Code Edition: Sprinkled: Project Title: Track#: Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: PC2020-0036 Plan Check#: Applied: 09/28/2020 Issued: 12/03/2020 Finaled Close Out: Inspector: Final Inspection: PBurn 09/30/2021 Description: BROWN: 5415F DETACHED 2ND FLOOR ADU/ 514 SF GARAGE/ 117 SF EXTERIOR STAIRCASE Applicant: BA WORTHING INC ALENA BLASIO 5145 AVENI DA ENCINAS, # STE I CARLSBAD, CA 92008 (760) 729-3965 FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) Property Owner: OWNER BROWN BELDEN H 265 CHINQAPUIN AVE CARLSBAD, CA 92008-7410 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Total Fees: $1,250.97 Total Payments To Date: Building Division $1,250.97 Contractor: BA WORTHING INC 5145 AVENIDA ENCINAS, # STE I CARLSBAD, CA 92008-4322 (760) 729-3965 Balance Due: AMOUNT $623.07 $436.15 $43.00 $52.00 $80.00 $4.00 $12.75 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov 1\f " w \ , , PE,RMIT: J;N,SPE~TION HISTQ-RY for (CB~2020-0192) Permit Type: BLDG-Associated Permit Residenti: Application Date: 09/28/2020 Owner: OWNER BROWN BELDEN H Work Class: Second Dwelling Unit Issue Date: 12/03/2020 Subdivision: CARLSBAD TCT#99-01 CARLSBAD BEACH ESTATES Status: Closed -Finaled Expiration Date: 11/01/2021 Address: 267 CHINQUAPIN AVE IVR Number: 28991 CARLSBAD, CA 92008-7410 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 03/18/2021 03/18/2021 BLDG-81 Underground 152965-2021 Passed Chris Renfro Complete Combo(11, 12,21,31) Checklist 1tcm COMMENTS Passed BLDG-Building Deficiency Yes BLDG-11 Foundation-Ftg-Piers Exterior stairs foundation Yes (Rebar) BLDG-12 Steel-Bond Beam Yes BLDG-21 Underground gas pressure test. Ok to Yes U nde rg rou nd-U nderfl oo r backfill Plumbing BLDG-31 Yes Underground-Conduit Wiring BLDG-83 Roof $heating, 153056-2021 Passed Chris Renfro Complete Exterior Shear (13, 15) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-13 Shear Panels-HD {ok Yes to wrap) BLDG-15 Roof Yes Sheathing-Reroof 05/04/2021 05/04/2021 BLDG-17 Interior 156557-2021 Passed Paul Burnette Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 09/30/2021 09/30/2021 BLDG-Final Inspection 167658-2021 Passed Chris Renfro Complete Checklist Item COMMENTS Passed BLOG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes Thursday, September 30, 2021 Page 2 of 2 Building Permit Inspection History Finaled (city of Carlsbad ~,,, 1 '''0½1 ,, \¾, ',,,, \, , .:~.' , 'PERMIT INSPEC1lTJ;ON'HIS;tORYfor (CBRA7020-0192) Permit Type: Work Class: StatLJS: Scheduled Date 12/22/2020 12/24/2020 01/06/2021 BLDG-Associated Permit Residenti: Second Dwelling Unit Application Date: 09/28/2020 Issue Date: 12/03/2020 Owner: OWNER BROWN BELDEN H Subdivision: CARLSBAD TCT#99-01 CARLSBAD BEACH ESTATES Closed -Finaled Expiration Date: IVR Number: 11/01/2021 28991 Address: 267 CHINQUAPIN AVE CARLSBAD, CA 92008-7410 Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Start Date 12/22/2020 Status BLDG•81 Underground 146781-2020 Partial Pass Chris Renfro Combo(11, 12,21,31) Checklist Item BLDG-Building Deficiency BLOG-11 Foundation-Ftg-Piers (Rebar) BLDG-12 Steel-Bond Beam BLDG-21 Underground-Underfloor Plumbing BLDG-31 Underground-Conduit Wiring COMMENTS Not ready Not ready Underground waste and water only through garage 12/24/2020 BLDG-11 147032-2020 Passed Chris Renfro F ou n datlo n/Ftg/Plers (Rebar) Checklist Item BLDG-Building Deficiency COMMENTS 01/06/2021 BLDG-12 Steel/Bond Beam 147756-2021 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS January 6, 2020: 1. Concrete slab, #4 reinforcement steel rebar @16" o.c. E.W., scope of work- approved. 2. Pre-grout Inspection for 2' ft. high, raised floor with 8" inch wide CMU masonry block, horizontal and vertical reinforcement steel rebar verified and masonry block cells cleaned out, scope of pre-grout inspection work-approved. BLDG-66 Grout Checklist Item 147633-2021 COMMENTS Passed Tony Alvarado BLDG-Building Deficiency January 6, 2020: 1. Concrete slab, #4 reinforcement steel rebar @16" o.c., scope of work - approved. 2. Pre-grout Inspection for 2' ft. high, raised floor with 8" inch wide CMU masonry block, horizontal and vertical reinforcement steel rebar verified and masonry block cells cleaned out, scope of pre-grout inspection work-approved. Relnspectlon Incomplete Passed Yes No No Yes No Complete Passed Yes Complete Passed Yes Complete Passed Yes Thursday, September 30, 2021 Page 1 of 2