Loading...
HomeMy WebLinkAbout2345 VIA FRANCISCA; ; CBCA2020-0025; PermitPERMIT REPORT ( City of Carlsbad Commercial Associated Permit Print Date: 04/28/2022 Job Address: 2345 VIA FRANCISCA, CARLSBAD, CA 92008-6828 Permit Type: BLDG-Associated Permit Commercial Work Class: Repair Parcel#: 1672504400 Track#: Valuation: $58,000.00 Lot#: Occupancy Group: Project#: #of Dwelling Units: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: PC2020-0019 Plan Check#: Project Title: Permit No: CBCA2020-0025 Status: Closed -Finaled Applied: 08/25/2020 Issued: 10/06/2020 Fina led Close Out: 04/28/2022 Inspector: Final Inspection: TAlva 08/27/2021 Description: THE RESERVE APARTMENTS: VOLUNATRY SEISMIC RETROFIT AT TUCK UNDER PARKING-BLDG #20 (2 OF 10) FEE BUILDING PLAN CHECK FEE (BLDG) BUILDING PERMIT FEE ($2000+) Property Owner: DP CARLSBAD MAGNI FICA INVESTORS LP DP AIRPORT HOSPITAL WAY INVESTORS LP C/0 DECRON PROPERTIES CORP 6222 WILSHIRE BLVD, # UNIT 400 LOS ANGELES, CA 90048 SB1473 GREEN BUILDING STATE STANDARDS FEE Total Fees: $713.02 Total Payments To Date: $713.02 Balance Due: 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov AMOUNT $268.58 $441.44 $3.00 $0.00 PERMIT INSPECTION HISTORY for (CBCA2020-0025) Permit Type: BLDG-Associated Permit Commerc Work Class: Repair Status: Closed -Finaled Application Date: 08/25/2020 Owner: D P CARLSBAD MAGNIFICA INVESTORS LP D P AIRPORT HOSPITAL WAY INVESTORS LP C/O DECRON PROPERTIES CORP Issue Date: 10/06/2020 Subdivision: PARCEL MAP NO 13126 Expiration Date: 02/28/2022 IVR Number: 28246 Address: 2345 VIA FRANCISCA CARLSBAD, CA 92008-6828 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Date Start Date Status 08/27/2021 08/27/2021 BLDG-Final Inspection 165308-2021 Passed Tony Alvarado Checklist Item BLDG-Structural Final COMMENTS August 27, 2021: No building deficiencies 1. Structural reinforcement To existing apartment complex units, soft story design with carport parking below units. 2. seismic structural reinforcement and modifications to existing garage moment frame carports, Per structural engineer's plans and detail specifications-approved. 08/30/2021 08/30/2021 BLDG-85 T-Bar, Ceiling 165358-2021 Cancelled Tim Kersch Thursday, April 28, 2022 Grids, Overhead Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers COMMENTS Reinspection Inspection Complete Passed Yes Reinspection Complete Passed No No No No No Page 2 of 2 Building Permit Inspection History Finaled ( City of Carlsbad PERMIT INSPECTION HISTORY for (CBCA2020-0025) Permit Type: BLDG-Associated Permit Commerc Application Date: 08/25/2020 Owner: D P CARLSBAD MAGNIFICA INVESTORS LP D P AIRPORT HOSPITAL WAY INVESTORS LP C/O DECRON PROPERTIES CORP Work Class: Status: Scheduled Date 03/19/2021 04/15/2021 04/20/2021 Repair Issue Date: Closed -Finaled Expiration Date: IVR Number: 10/06/2020 02/28/2022 28246 Subdivision: PARCEL MAP NO 13126 Address: 2345 VIA FRANCISCA CARLSBAD, CA 92008-6828 Actual Inspection Type Inspection No, Inspection Primary Inspector Reinspection Inspection Start Date Status 03/19/2021 BLDG-12 Steel/Bond 153128-2021 Partial Pass Tony Alvarado Beam Checklist Item COMMENTS BLDG-Building Deficiency March 19, 2021: 04115/2021 BLDG-16 Insulation Checklist Item 1. No Building/Multi-family structural reinforcement Deficiencies). 2. approved and OK to pour first phase concrete footings/isolated pad footings at columns, for garage carport areas, soft-story, multi-family units seismic reinforcement retrofit. 3. Approved and OK to cover up patched openings with drywall and stucco lath patches, under-side garage carport locations, per structural engineer's plans and detail specifications. 4. Deputy inspector report verified for isolated pad footing, retrofit steel reinforcement dowels and isolated pad footings steel reinforcement rebar - approved. 154967-2021 COMMENTS Passed Tony Alvarado BLDG-Building Deficiency April 15, 2021: 1. Nope Building Deficiencies. 2. Energy compliant insulation, installed at all ceiling neath all habitable living spaces above, at repaired/remodeled-seismic retrofit, soft-story new moment frame for apartment building units. 04/20/2021 BLDG-18 Exterior Lath/Drywall 155540-2021 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS April 20, 2021 :(Virtual inspection). 1. No building/exterior stucco lath Deficiencies. 2. Final exterior stucco lath-Type, size, and nailing pattern, metal weep screed installation, silicone caulking sealed at stucco lath paper penetrations, scope of lath paper work Inspection-Approved. Reinspection Incomplete Passed Yes Complete Passed Yes Complete Passed Yes Thursday, April 28, 2022 Page 1 of 2