Loading...
HomeMy WebLinkAbout2325 VIA CLEMENTE; ; CBCA2020-0028; PermitPERMIT REPORT ( City of Carlsbad Commercial Associated Permit Print Date: 04/28/2022 Job Address: 2325 VIA CLEMENTE, CARLSBAD, CA 92008-6804 Permit Type: BLDG-Associated Permit Commercial Work Class: Repair Parcel#: 1672504400 Track#: Valuation: $58,000.00 Lot#: Occupancy Group: Project#: #of Dwelling Units: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: PC2020-0019 Plan Check#: Project Title: Permit No: CBCA2020-0028 Status: Closed -Finaled Applied: 08/25/2020 Issued: 10/06/2020 Fina led Close Out: 04/28/2022 Inspector: Final Inspection: PBurn 08/27/2021 Description: THE RESERVE APARTMENTS: VOLUNATRY SEISMIC RETROFIT AT TUCK UNDER PARKING-BLDG #18 (5 OF 10) FEE BUILDING PLAN CHECK FEE (BLDG) BUILDING PERMIT FEE ($2000+) Property Owner: DP CARLSBAD MAGNIFICA INVESTORS LP DP AIRPORT HOSPITAL WAY INVESTORS LP C/0 DECRON PROPERTIES CORP 6222 WILSHIRE BLVD, # UNIT 400 LOS ANGELES, CA 90048 SB1473 GREEN BUILDING STATE STANDARDS FEE Total Fees: $728.73 Total Payments To Date: $728.73 Balance Due: 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov AMOUNT $284.29 $441.44 $3.00 $0.00 Building Permit Inspection History Finaled {_ City of Carlsbad PERMIT INSPECTION HISTORY for (CBCA2020-0028) Permit Type: BLDG-Associated Permit Commerc Work Class: Repair Status: Closed -Finaled Scheduled Actual Inspection Type Date Start Date 05/20/2021 05/20/2021 BLDG-11 F ou n dation/Ftgf Piers (Rebar) 06/08/2021 06/08/2021 BLOG-12 Steel/Bond Beam 06/22/2021 06/22/2021 BLDG-18 Exterior Lath/Drywall Checklist Item Application Date: 08/25/2020 Owner: D P CARLSBAD MAGNIFICA Issue Date: INVESTORS LP DP AIRPORT HOSPITAL WAY INVESTORS LP C/O DECRON PROPERTIES CORP 10/06/2020 Subdivision: PARCEL MAP NO 13126 Expiration Date: 12/20/2021 Address: 2325 VIA CLEMENTE CARLSBAD, CA 92008-6804 IVR Number: 28249 Inspection No. Inspection Primary Inspector Reinspection Inspection Status 157768-2021 Partial Pass Tony Alvarado Reinspection Incomplete 159119-2021 Passed Tony Alvarado Complete 160227-2021 Passed Tony Alvarado Complete COMMENTS Passed BLDG-Building Deficiency June 22, 2021. (Virtual inspection). Virtual inspection completed on Monday, June 21, 2021, Yes No Exterior stucco wire lath/Interior carport drywall repair deficiencies. 1. Verified installation of drywall repair, like for like, same size same location, gypsum board scope of work-Approved. 2. Exterior repair to existing stucco wire lath, for new seismic structural retrofit components, grade beam and moment steel frame, scope of work-approved. 08/27/2021 08/27/2021 BLDG-Final Inspection 165314-2021 Passed Tony Alvarado Checklist Item BLDG-Structural Final Thursday, April 28, 2022 COMMENTS August 27, 2021: No building deficiencies 1. Structural reinforcement To existing apartment complex units, soft story design with carport parking below units. 2. seismic structural reinforcement and modifications to existing garage moment frame carports, Per structural engineer's plans and detail specifications-approved. Complete Passed Yes Page 1 of 1