HomeMy WebLinkAbout2325 VIA SANTOS; ; CBCA2020-0031; PermitPERMIT REPORT ( City of Carlsbad Commercial Associated Permit Print Date: 04/28/2022 Job Address: 2325 VIA SANTOS, CARLSBAD, CA 92008-6814 Permit Type: BLDG-Associated Permit Commercial Work Class: Repair Parcel#: 1672504400 Track#: Valuation: $58,000.00 Lot#: Occupancy Group: Project#: #of Dwelling Units: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: PC2020-0019 Plan Check#: Project Title: Permit No: CBCA2020-0031 Status: Closed• Finaled Applied: 08/25/2020 Issued: 10/06/2020 Fina led Close Out: 04/28/2022 Inspector: Final Inspection: TAlva 09/02/2021 Description: THE RESERVE APARTMENTS: VOLUNATRY SEISMIC RETROFIT AT TUCK UNDER PARKING· BLDG #13 (8 OF 10) FEE BUILDING PLAN CHECK FEE (BLDG) BUILDING PERMIT FEE ($2000+) Property Owner: DP CARLSBAD MAGNI FICA INVESTORS LP DP AIRPORT HOSPITAL WAY INVESTORS LP C/0 DECRON PROPERTIES CORP 6222 WILSHIRE BLVD, # UNIT 400 LOS ANGELES, CA 90048 SB1473 GREEN BUILDING STATE STANDARDS FEE Total Fees: $728.73 Total Payments To Date: $728.73 Balance Due: 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov AMOUNT $284.29 $441.44 $3.00 $0,00 PERMIT INSPECTION HISTORY for (CBCA2020-0031) Permit Type: BLDG-Associated Permit Commerc Work Class: Repair Status: Scheduled Date 09/02/2021 Closed -Finaled Actual Inspection Type Start Date 09/02/2021 BLDG-Final Inspection Checklist Item BLDG-Structural Final Thursday, April 28, 2022 Application Date: 08/25/2020 Owner: D P CARLSBAD MAGNIFICA INVESTORS LP DP AIRPORT HOSPITAL WAY INVESTORS LP C/O DECRON PROPERTIES CORP Issue Date: 10/06/2020 Subdivision: PARCEL MAP NO 13126 Expiration Date: 02/22/2022 IVR Number: 28252 Address: 2325 VIA SANTOS CARLSBAD, CA 92008-6814 Inspection No. Inspection Primary Inspector Reinspection Inspection 165730-2021 COMMENTS Status Passed Tony Alvarado September 2, 2021: Final inspection approved. No building deficiencies 1. Structural reinforcement To existing apartment complex units, soft story design with carport parking below units. 2. seismic structural reinforcement and modifications to existing garage moment frame carports, Per structural engineer's plans and detail specifications-approved. Complete Passed Yes Page 2 of 2 Building Permit Inspection History Finaled (city of Carlsbad PERMIT INSPECTION HISTORY for (CBCA2020-0031} Permit Type: BLDG-Associated Permit Commerc Application Date: 08/25/2020 Owner: D P CARLSBAD MAGNIFICA INVESTORS LP D P AIRPORT HOSPITAL WAY INVESTORS LP C/O DECRON PROPERTIES CORP Work Class: Status: Scheduled Date 07/23/2021 08/12/2021 08/26/2021 Repair Issue Date: Closed -Finaled Expiration Date: IVR Number: 10/06/2020 02/22/2022 28252 Subdivision: PARCEL MAP NO 13126 Address: 2325 VIA SANTOS CARLSBAD, CA 92008-6814 Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Start Date Status 07/23/2021 BLDG-11 162643-2021 Partial Pass Tony Alvarado Foundation/Ftg/Piers (Rebar) Checklist Item BLDG-Building Deficiency COMMENTS July 23, 2021: 1. No footings/foundation-steel reinforcement building deficiencies. 2. Third-party deputy inspectors report for steel reinforcement; type, size and placement location, verified and received-approved. 3. Footing and foundation steel reinforcement: type, size, epoxied rebar, and rebar placement location, per structural engineers plans and detail specifications-approved. 08/12/2021 BLDG-12 Steel/Bond Beam 164092-2021 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS August 12, 2021: 1. Grade beam -steel rebar reinforcement, seismic soft-story reinforcement for new steel moment frame retrofit, per structural engineered plans and detail specifications-approved. 2. OK to pour concrete. 3. Verified and received all third-party/deputy inspectors reports. 08/26/2021 BLDG-18 Exterior Lath/Drywall 165161-2021 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS August 26, 2021: (virtual inspection). 1. No exterior metal wire stucco lath Deficiencies. 2. New exterior metal stucco wire lath paper, metal weep screed, and all penetrations sealed with silicone, (typical) -scope of work-approved. 3. Exterior garage Gypsum/drywall board patch/repair; type, size, and fasteners-method of attachment anchoring system-approved. Reinspection Incomplete Passed Yes Complete Passed Yes Complete Passed Yes Thursday, April 28, 2022 Page 1 of 2