HomeMy WebLinkAboutPRE 2022-0013; OLIVE GARDEN; Admin Decision LetterApril 28, 2022
Nina Raey
3187-A Airway Avenue
Costa Mesa, CA 92626
SUBJECT:
Dear Ms. Raey,
PRE 2022-0013 (DEV2022-0053) -OLIVE GARDEN
APN 156-302-07-00
{"city of
Carlsbad
,--,
l.J f ILE CO PY
1YJ,.,,·1el s/;/22
Thank you for submitting a preliminary review application for an Olive Garden restaurant at 2515 El
Camino Real located within Planning Area 3 of the Westfield Carlsbad Specific Plan (SP 09-0l(B)). The
project site, an approximately 0.44-acre lot, currently is developed with an existing building that was
previously occupied by the Luxe Buffet restaurant.
In response to your application, the Planning Division has prepared this comment letter. Please note that
the purpose of a preliminary review is to provide you with direction and comments on the overall concept
of your project. This preliminary review does not represent an in-depth analysis of your project. It is
intended to give you feedback on critical issues based upon the information provided in your submittal.
This review is based upon the plans. policies, and standards in effect as of the date of this review. Please
be aware that at the time of a formal application submittal, new plans. policies, and standards may be
in effect and additional issues of concern may be raised through a more specific and detailed review.
Planning:
General
1. General Plan and Zoning designations for the property are as follows:
a. General Plan: R (Regional Commercial)
b. Zoning: C-2 (General Commercial)
c. Specific Plan: Westfield Carlsbad Specific Plan (SP 09-0l(B)), Planning Area 3
https://www.carlsbadca.gov/home/showpublisheddocument/6988/637614204976670000
2. The project requires the following permits:
1. Site Development Plan (SOP).
2. Nonconforming Construction Permit (NCP).
Community Development Department
Planning Division j 1635 Faraday Avenue Carlsbad, CA 92008-7314 I 442-339-2600 www.carlsbadca.gov
PRE 2022-0013 (DEV2022-0053) -OLIVE GARDEN
April 28, 2022
Page 2
Not enough information has been provided with this preliminary review application to determine the
specific Development Review Process as outlined in the specific plan (Section 6.0, pg. 6-1). For this,
you will need to provide detailed exhibits that compare the existing structure height and the square
· footage to that being proposed. Then determine the percentage of change that is being proposed for
each category and compare it against Table-6 on pg. 6-1 of the specific plan for Out-Buildings to
determine if the decision maker for the SOP discussed above can be made administratively (i.e., City
Planner) or by the Planning Commission.
3. It's unclear from the single exhibit, showing a floor plan graphically overlaid on an a rial photo of the
building, the degree to which the existing building footprint may be changing. The existing building is
generally rectangular in shape. The proposed exhibits show some form of building articulation that
infers changes to, expansion of, or possibly a reduction in, certain areas of the building footprint. All
these changes need to be fully confirmed and vetted as part of a formal application submittal process
with refined exhibits as discussed above.
Please note that the building and landscape setback requirements associated with the Planning Area
3 Development Standards (pg. 5-11) of the specific plan requires a minimum 15.,foot building and
landscape setback as measured from the back of sidewalk along El Camino Real. The existing building
is presently setback approximately 13 feet from the back of sidewalk with an outdoor storage area
enclosed by solid masonry walls that is setback approximately 3.5 feet from the back of sidewalk.
Existing buildings are permitted to remain at existing setbacks, but if modifications are made, then
the requirements of the nonconforming section (Section 2.6) of the specific plan shall apply. To this
point, the proposed floor plan appears to show the outdoor storage area along El Camino Real possibly
being enclosed as conditioned floor area. Please note that the existing building qualifies as a
nonconforming non-residential structure because of inadequate setbacks. While the existing footprint
can be expanded with a NCP, an increase in the degree of existing nonconformity however cannot be
supported or approved.
The proposed improvements to the existing building, as shown in the preliminary review application
exhibits, would not constitute redevelopment ofthe area. However, demolition ofthe building would
constitute redevelopment and all requirements of the specific plan for this area, including but not
limited to, landscape improvements along El Camino Real, Haymar Drive, and the adjacent parking
field would be triggered as discussed in Section 4.2 ofthe Landscape Design Guidelines.
4. The preliminary review application discusses landscape changes. A formal submittal will need to
include concept landscape and irrigation plans that describe the level of change being proposed. The
concept plans shall be designed in accordance with both the Landscape Guidelines of the specific plan
and the City of Carlsbad's Landscape Manual Policies and Requirements. The City of Carlsbad's
Landscape Manual document can be found on the Planning Division's web page at the following
address:
https:// ca rlsbadca. prod .govaccess.org/home/showdocu ment?id= 7032
5. Building signage must comply with the specific plan and the approved sign program for the Shoppes
at Carlsbad Shopping Center. The preliminary review application exhibits are showing four (4) facia
tenant signs, one on each building elevation. Please note that the approved sign program allocated
two (2) facia tenant signs to this building, one (1) facing west towards the parking lot and one (1)
facing east towards El Camino Real. Additional facia tenant signs will not be permitted. Please also
note that signage is approved under separate permit.
PRE 2022-0013 (DEV2022-0053)-OLIVE GARDEN
April 28, 2022
Page 3
6. New requirements related to the city's goals to reduce greenhouse gas (GHG) emissions will likely
impact development requirements of this project. A formal application submittal'will need to include
a completed Climate Action Plan Checklist (Form P-30) to determine what requirements will apply to
the project. New GHG reduction requirements are related to energy efficiency, photovoltaic, electric
vehicle charging, water heating and traffic demand management requirements, as set forth in the
California Green Building Standards Code and in Carlsbad Municipal Code Chapters 18.21, 18.30 and
18.51 which is available on the city's website at the following address:
http://www.gcode.us/codes/carlsbad/view.php?topic=18&frames=on
To the extent that new GHG reduction requirements are in effect at the time of application for grading
or building permits, the project will be required to comply with the effective requirements even if
different than what is proposed in the project's planning approvals. GHG reduction requirements may
impact, but are not limited to, site design and local building code requirements. If incorporating new
GHG reduction requirements results in· substantial modifications to the project after planning
approvals are obtained, then prior to issuance of grading or building permits, the applicant may be
required to submit and receive approval of a Consistency Determination or an Amendment
application for the project through the Planning Division.
All necessary application forms, submittal requirements, and fee information are available at the Planning
counter located in the Faraday Building at 1635 Faraday Avenue or online at
https://www.carlsbadca.gov/departments/community-development/planning. You may also access the
General Plan Land Use Element and the Zoning Ordinance online at the website address shown. Please
review all information carefully before submitting.
Land Development Engineering:
1. Please complete the City's Storm Water Standards Questionnaire (Form E-34). This questionnaire will
guide you and the city in determining what type of reports and storm water mitigation must be
completed to satisfy state and city storm water quality requirements. The questionnaire can be
obtained on the City of Carlsbad's web site. Preliminary analysis suggests that the project is not a
development project.
2. Please complete the City of Carlsbad's Storm Water Compliance Form Tier 1 Construction SWPPP (Form
E-29) and identify any construction Best Management Practices (BMPs) to be used on the project site
during the improvements. The template can be found on the City of Carlsbad's website.
3. Please provide the change in average daily traffic, as well as the change in water demands (GPM or
GPO) and sewer generation (EDU) resulting from the project. List even if net change is zero.
Fire Department:
1. If no additional square footage is being added, then the Fire Department has no requirements for this
proposal.
2. Alterations to the kitchen/floor plan shall be reviewed by the Fire Department.
Building Division:
1. The Building Division has no comments regarding the conceptual exhibits included with this
preliminary review application submittal.
PRE 2022-0013 (DEV2022-0053) ~ OLIVE GARDEN
April 28, 2022
Page 4
2. The following comments are provided courtesy of the Building Division, and will need to be clearly
detailed in your final design prior to submitting for building permit construction plan review:
a. The City of Carlsbad enforces the 2019 California Building Codes.
b. Fats, Oils, Grease requirements are found in the city's municipal code within chapter 13.06.
Details should be on the plans prior to submitting for plan review. A grease interceptor will
be required.
c. Carlsbad Climate Action Plan application (B-50) will be required at permit application
submission. This program is valuation based. Appropriate details will need to be on the plans
based on outcome of the B-50 application.
d. The B-2 commercial permit application will be required.
e. The B-59 waste management application may need to be included if project valuation exceeds
200k.
f. 60-inch accessible bar area will need to be shown in the design.
g. A-2 occupancy is required for occupant load and egress.
h. Plumbing facilities will be based on 2019 CPC section 422. Indoor and outdoor square footage
to be considered for calculating minimum plumbing facilities.
If you would like to schedule a meeting to discuss this letter with the commenting departments, please
cqntact Jason Goff at the number below. You may also contact each department individually as follows:
• Planning Division: Jason Goff, Senior Planner, at (442) 339-2643
• Land Development Engineering: Nichole Fine, Project Engineer, at (442) 339-2744
• Fire Department: Randy Metz, Fire Inspections, at (442) 339-2661
• Building Division: Jason Pasiut, Building Manager, at (442) 339-2788
Sincerely,
Cl?'L
DON NEU, AICP
City Planner
DN:JG:cf
c: RPI Carlsbad, L.P., 350 North Orleans Street, Suite 300, Chicago, IL 60654-1607
Nichole Fine, Project Engineer
Fire Prevention
Laserfiche/File Copy
Data Entry