HomeMy WebLinkAbout2701 LOKER AVE W; ; PC2021-0009; PermitPERMIT REPORT
Plan Check Permit
Print Date: 05/11/2022
Job Address: 2701 LOKER AVE W, CARLSBAD, CA 92010-6637
Permit Type: BLDG-Plan Check Work Class: Commercial
Parcel #: 2090812200 Track#:
Valuation: $0.00 Lot#:
Occupancy Group: Project#:
#of Dwelling Units: Plan#:
Bedrooms: Construction Type:
Bathrooms: Orig. Plan Check#:
Plan Check#:
Project Title:
Status:
(city of
Carlsbad
Permit No: PC2021-0009
Closed -Finaled
Applied: 02/12/2021
Issued: 03/15/2021
Finaled Close Out: 11/17/2021
Inspector:
Final Inspection:
Description: PACIFIC WESTERN BANK: 15,955 SF OFFICE TO OFFICE Tl IN 5 SUITES AT 1ST & 2ND FLOOR
FEE
Property Owner:
REEF PALOMAR LLC
2701 LOKER AVE
CARLSBAD, CA 92008
BUILDING PLAN REVIEW-MINOR PROJECTS (LDE)
BUILDING PLAN REVIEW -MINOR PROJECTS (PLN)
MANUAL BLDG PLAN CHECK FEE
Total Fees: $1,792.00 Total Payments To Date: $1,500.00 Balance Due:
1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
AMOUNT
$194.00
$98.00
$1,500.00
$292.00
( City of
Carlsbad
COMMERCIAL
BUILDING PERMIT
APPLICATION
B-2
Plan Check ~202.\ -CI)C)q
Est. Value :=}y21 Ol,o3·
PC Deposit
Date 2,-I :::Z. -2.1
Job Address 2701 Loker Avenue Carlsbad. CA 92010 Suite:, ____ APN: _2_0_9-_0_81_-2_2_-o_o _____ _
Tenant Nam~. ffiQ,,\f\(' 1 \_}Je;pt ~[ Q fi_u) ~ Lot#: TR 10372 Lot 22
IA . . 8D 8D Year Built: 1999 Occupancy: 8 Office Construction Type· Fire Sprinklers: yes no A/C: yes no
BRIEF DEscRIPnoN oFwoRK, ~~ro\J~ts iv :) <ou,~v '! fu\.:tlt'll-\~~::;:\ /X:.35-f;
~ 'J,_3~')::;. \;li '36 ~ 1 'It-2--'\Cr=-4 ?:i 7 2 S\, 1t: 17 0 = .2.., \ 0,:-:J S', ~ 2-so = l9 3 l r·
D Addition/New: ___________ New SF and Use, ___________ New SF and Use,
____ Deck SF, Patio Cover SF (not including flatwork)
~ Tenant lmprovement:_1_5,_95_5 ___ SF, Existing Use General Office Proposed Use General Office
_____ SF, Existing Use ______ Proposed Use ______ _
D Pool/Spa:, _____ SF Additional Gas or Electrical Features? ___________ _
DD DD DD D Solar:, ___ KW,, ___ Modules, ___ ,Mounted, Tilt: Yes/ No, RMA: Yes/ No, Panel Upgrade: Yes/ No
D Plumbing/Mechanical/Electrical Only: _________________________ _
D Other:
This permit is to be issued in the name of the Property Owner as Owner-Builder, licensed contractor or Authorized Agent of the
owner or contractor. The person listed as the Applicant below will be the main point of contact throughout the permit process.
PROPERTY OWNER APPLICANT O PROPERTY OWNERS AUTHORIZED AGENT APPLICANT 0
Name: Erin Justin-Scott Na me: Un ire Real Estate Group
Address: 1200 6th Ave. S. #700 Address: 1800 East Imperial Highway. Suite 205
City: Seattle State:_W_A __ ,Zip: 98134 City: Brea State:_C_A __ ,Zip: 92821
Phone: ________________ Phone: (714) 990-2100
Email: Harryman@UnireGroup.com Email: Harryman@UnireGroup.com
& if'I SLDtt
DESIGN PROFESSIONAL APPLICANT [i CONTRACTOR BUSINESS APPLICANT 0
Name: Hurkes Harris Design Associate Name: White Construction/ SWP Construction Inc.
Address: 3838 Camino Del Rio North. Suite 252 Address: 2524 Gateway Road
City: San Diego State: CA Zip:_9_21_o_s __ City: Carlsbad State: CA Zip:_9_2_O_O_9 ___ _
Phone: (619) 702-0380 X119 Phone: (760) 931-1130
Email: ejustinscott@hhdainc,com Email: darrin@whiteconstructioninc.com
Architect State License: State License:4~2? \?:, Bus. License: O,u [V\ e /\:1
1635 Faraday Ave Carlsbad, CA 92008
B-2
Ph: 760-602-2719 Fax: 760-602-8558
Page 1 of 2
Email: Building@carlsbadca.gov
Rev. 08/20
IDENTIFY WHO WILL PERFORM THE WORK BY COMPLETING (OPTION A) OR (OPTION B) BELOW:
(OPTION A): LICENSED CONTRACTOR DECLARATION:
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. I also affirm under
penalty of perjury one of the following declarations:
0 I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of
the work which this permit is issued. Policy No. ________________________ _
Iii I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
My workers' compensation insurance carrier and policy number are: lnsuranceCompany Name: STATE coMPENsAr10N 1NsURANcE FUND
Policy No._"'_"_°'_"--" __________________ Expiration Date: -'-"'-'"-"-------------------
□ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to
become subject to the workers' compensation laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an
employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the
Labor Code, interest and attorney's fees.
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name: _____________________ ,Lender's Address: ____________________ _
_ ,......,.,,,_.,.,,,. cro
CONTRACTOR PRINT: _s_te_v_e_W_h_i_te _____ _ SIGN: Ste,eWhite-CEO~~:,cf'3:.iF""' DATE: 02.10.2021
(OPTION B): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's License Law for the following reason: DI, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and who does such
work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
DI, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's license law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s)
licensed pursuant to the Contractor's License Law).
DI am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason:
D "Owner Builder acknowledgement and verification form" has been filled out, signed and attached to this application. Proof of identification attached.
D Owners "Authorized Agent Form" has been filled out, signed and attached to this application giving the agent authority to obtain the permit on the owner' behalf
Proof of identification attached.
By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the
improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed
contractors. I understand that a copy of the applicable low, Section 7044 of the Business and Professions Code, is available upon request when this application is
submitted or at the following Web site: http://www.leginfo.ca.gov/calaw.html.
OWNER PRINT: ____________ SIGN: _________ ,DATE: ______ _
APPLICANT CERTIFICATION: SIGNATURE REQUIRED AT THE TIME OF SUBMITTAL
By my signature below, I certify that: I am the property owner or State of California licensed Contractor or authorized to act on the property
owner or contractor's behalf. I certify that I have read the application and state that the above information is correct and that the
information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE,
INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY
ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0'
deep and demolition or construction of structures over 3 stories in height.
APPLICANT PRINT: ~Y"i r. Jvs-tin-Sc<rtt
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov
8-2 Page 2 of 2 Rev. 08/20
•
DATE: FEB.22,2021
JURISDICTION: CARLSBAD
PLAN CHECK#.: PC2021-0009
✓• EsG1I
A SAFEbu1lt Compc1ny
SET: I
PROJECT ADDRESS: 2701 LOCKER AVENUE
□ APPLICANT
□ JURIS.
PROJECT NAME: T.I. FOR SUITES #155, #235 & #240, #250 & #270
[8J The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil until
corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
~ EsGil staff did not advise the applicant that the plan check has been completed.
D EsGil staff did advise the applicant that the plan check has been completed.
Person contacted:
Date contacted: (by: )
Mail Telephone Fax In Person
0 REMARKS:
By: ALI SADRE S.E., CASp
EsGil
Telephone#:
Email:
Enclosures:
2/17
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
CARLSBAD PC2021-0009 SET: I
FEB.22,2021
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: CARLSBAD
PREPARED BY: ALI SADRE S.E., CASp
BUILDING ADDRESS: 2701 LOCKER AVENUE
BUILDING OCCUPANCY: B; 1-A/SPR.
BUILDING D Valuation Reg.
PORTION Multiplier Mod.
T.I. 15955
Air Conditioning
Fi re Sprinklers
TOTAL VALUE
Jurisdiction Code CB By Ordinance
1997 UBC Building Permit Fee ...
j 1997 UBC Plan Check Fee
Type of Review: r;; Complete Review
r Repetitive Fee "'II I~ Repeats
r Other
r Hourly
EsGil Fee
Comments:
PLAN CHECK#.: PC2021-0009
DATE: FEB.22,2021
VALUE ($)
742,067
r Structural Only
$1,798.077
Sheet 1 of 1
ProjecL
ENGINEERING
STRUCTURAL CONSULTING ENGINEERS
BOZEMAN, MT
P. (406) 582-7911 F. (406) 587-0673
SAN DIEGO, CA
P. (B58) 273-315B F.1858) 270-197B
STRUCTURAL CALCULATIONS
Pacific Western Bank Tl Plan Check, 100% Plan check
Submittal
Dale, 2-10-21 Location, Loker Drive, Carlsbad
CA
i-10-2-1
Prepared for,
f-lurke& f-larri& Design A&&ocaite&
San Diego, CA
0 ..-
0 N NO
NN ..---co N
0 !:: O'l N 0 N
0)
0
0
0
I
'I""'
N
0
N
(.) a..
SAN DIEGO californla BOZEMAN mantana 406.582. 7911 Fax: 406.587.0673
,_
' '
' ..
. ,
SAN DIEGO cellfornl• BOZEMAN montana 406.582.7911 Fax:406.587.0673
Title Block Line 1
You can change this area
using the "Settings" menu item
and then using the "Printing &
Title Block" selection.
Title Block Line 6
Project Title:
Engineer:
Project ID:
Project Descr:
ASCE Seismic Demands on Nonstructural Components
1,11" I
Seismic Demands on Nonstructural Components per ASCE 7-16 Section 13.3.1 and 13.4.1
h = 30.0 ft s05 = 0.6970
Description : HP 314n
ap = 1.00 WP= 180.0( z = 20.00ft Rp =
Fp Upper Limit = 200.74 Fp Calc'd : Components=
Connections = Fp Lower Limit = 37.64
aP w : p z
RP
IP
Component amplification factor, Table 13.5-1 or Table 13.6-1
Component operating weight
Height of point of attachment
Component response modification factor (Table 13.5-1 or Table 13.6-1)
Component importance factor (Section 13.1.3)
2.50 IP =
46.84
46.84
1.00 z/h : Actual = 0.67 z/h Design =
Fp Calc'd
Fp-Upper
Fp -Lower
Fp -Design
Fp DESIGN : Components
Connections
= 46.84
46.84
Calculated Fp, Eq (13.3-1), Same un!s as Wp
Upper Limit on Fp, Eq (13.3-2) ,(Same units as Wp
Lower limit on Fp, Eq (13.3-3), Same units as Wp
Fp for design purposes, Same units as Wp
0.67
Title 'Block Line 1
You can change this area
using the 'Settings" menu item
and then using the 'Printing &
Title Block' selection
Title Block Line 6
Project Title:
Engineer:
Project ID:
Project Descr:
Wood Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24
I• II' I
DESCRIPTION: (E) ROOF JOIST
CODE REFERENCES
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set: ASCE 7-16
Material Properties
..
Analysis Method : Allowable Stress Design
Load Combination ASCE 7-16
Fb + 1,300.0 psi
1,300.0psi
925.0psi
625.0psi
170.0psi
675.0psi
E: Modulus of Elasticity
Wood Species
Wood Grade
: Oouglas Fir-Larch (North)
· No.1
Fb-
Fc-Prll
Fe -Perp
Fv
Ft
Beam Bracing : Beam is Fully Braced against lateral-torsional buckling
D(0.18)
D(O 03 +I((L~4)
2x6
r-Span= 8.0 fl
------------------
Ebend-xx 1,600.0ksi
Eminbend -xx 580.0ksi
Density 30.590pcf
i
Applied Loads Service loads entered. Load Factors will be applied for calculations
Uniform Load: D = 0.0150, Lr= 0.020 ksf, Tributary Width= 2.0 ft
Point Load: D = 0.180 k@4.0 ft
DESIGN SUMMARY
Maximum Bending Stress Ratio 0.691: 1 Maximum Shear Stress Ratio
Section used for this span 2x6 Section used for this span
fb: Actual 1,459.83psi fv: Actual
Fb: Allowable 2, 112.50psi Fv: Allowable
Load Combination +D+Lr+H Load Combination
Location of maximum on span 4 000ft Location of maximum on span
Span # where maximum occurs Span# 1 Span # where maximum occurs
Maximum Deflection
Max Downward Transient Deflection 0.111 in Ratio= 861 >=240
Max Upward Transient Deflection 0.000 in Ratio= 0<240
Max Downward Total Deflection 0.295 in Ratio= 325>=180
Max Upward Total Deflection 0.000 in Ratio= 0<180
Maximum Forces & Stresses for Load Combinations
load Combination Max Stress Ratios Moment Values
Segment length Span# M V Cd C FN C; Cr Cm Ct CL M fb
<D+H
Length= 8.0 ft 0.626 0.234 0.90 1300 1.00 1.00 1.00 1.00 1.00 0.60 952.07
<D+L+H 1.300 1.00 1.00 1.00 1.00 1.00
Length= 8.0 ft 0.563 0.211 1.00 1.300 1.00 1.00 1.00 1.00 1.00 0.60 952.07
+D-tlr+H 1.300 1.00 1.00 1.00 1.00 1.00
Length = 8.0 ft 0.691 0.290 1.25 1.300 1.00 1.00 1.00 1.00 1.00 0.92 1,459.83
+D+S+H 1.300 1.00 1.00 1.00 1.00 1.00
Length= 8.0 ft 0.490 0.183 1.15 1.300 1.00 1.00 1.00 1.00 1.00 0.60 952.07
<ll+0.750Lr+O. 750L +H 1.300 1.00 1.00 1.00 1.00 1.00
Length= 8.0 ft 0.631 0.260 1.25 1300 1.00 100 100 1.00 1.00 0.84 1,332.89
<ll+0.750L +0.750S+H 1.300 1.00 1.00 1.00 1.00 1.00
Length= 8.0 ft 0.490 0.183 1.15 1.300 1.00 1.00 1.00 1.00 1.00 0.60 952.07
<D+O 60W+H 1.300 1.00 1.00 1.00 1.00 1.00
Design OK
0.290: 1
2x6
61.70psi
212.50 psi
+D+Lr+H
7.562ft
Span# 1
Shear Values
F'b V fv F'v
0.00 0.00 0.00 0.00
1521.00 0.20 35.79 153.00
0.00 0.00 0.00 0.00
1690.00 0.20 35.79 170.00
0.00 0.00 0.00 0.00
2112.50 0.34 61.70 212.50
0.00 0.00 0.00 0.00
1943.50 0.20 35.79 195.50
0.00 0.00 0.00 0.00
2112.50 0.30 55.22 212.50
0.00 0.00 0.00 0.00
1943.50 0.20 35.79 195.50
0.00 0.00 0.00 0.00
Title'Block Line 1
You can change this area
using the "Settings" menu item
and then using the 'Printing &
Title Block' selection
Title Block Line 6
Wood Beam
1,11' I
DESCRIPTION: (E) ROOF JOIST
Load Combination Max Stress Ratios
Segment Length Span# M V
Length= 8.0 ft 1 0.352 0.132
+0..0. 750Lr..O. 750L ..0.450W+H
Length= 8 Oft 1 0.493 0.203
+0..0. 750L ..0.750S..0.450W+H
Length= 8.0 ft 1 0.352 0.132
..0.60D..0.60W..O 60H
Length = 8.0 ft 0.211 0.079
+0..0.IOE..O 60H
Length= 8.0 ft 1 0.352 0.132
+0..0. 750L ..0. 750S..0.5250E+H
Length = 8.0 ft 1 0.352 0.132
..0.60D..0.70E+H
Length= 8.0 ft 1 0.211 0.079
Overall Maximum Deflections
Load Combination Span
+D<lr+H 1
Vertical Reactions
Load Combination
Overall MAXimum
Overall M!Nimum
<ll+H
+O<l+H
+D<lr+H
+D+S+H
+0..0.750Lr..0.750L +H
+0..0.750L ..0.750S+H
+0..0 60W+H
+0..0. 750Lr..O. 750L ..0.450W+H
+0..0.750L ..0 750S..0.450W+H
..0.60D..O 60W..0.60H
+0..0.70E..0.60H
+D..O. 750L ..0 750S..0.5250E+H
..0.60D..0.70E+H
D Only
Lr Only
H Only
Project Title:
Engineer:
Project ID:
Project Descr:
Printed 10 FEB 2021, 9.04AM
Fik>: PWB MECH SUPP T.
Software copyright ENERCAlC, INC. 1983-2020, Buitd:12.20.8.24 ..
Moment Values Shear Values
Cd C FN C; c, Cm C t CL M fb F'b V fv F'v
1.60 1.300 1.00 1.00 1.00 1.00 1.00 0.60 952.07 2704.00 0.20 35.79 272.00 1.300 1.00 1.00 1.00 1.00 1.00
1.60 1.300 1.00 1.00 1.00 1.00 1.00
0.00 0.00 0.00 0.00
0.84 1,332.89 2704.00 0.30 55.22 272.00 1.300 1.00 1.00 1.00 1.00 1.00
1.60 1.300 1.00 1.00 100 1.00 1.00
0.00 0.00 0.00 0.00
0.60 952.07 2704.00 0.20 35.79 272.00 1.300 1.00 1.00 1.00 1.00 1.00
1.60 1.300 1.00 1.00 1.00 1.00 1.00
0.00 0.00 0.00 0.00
0.36 571.24 2704.00 0.12 21.48 272.00 1.300 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1.60 1.300 1.00 1.00 1.00 1.00 1.00 0.60 952.07 2704.00 0.20 35.79 272.00 1.300 1.00 1.00 1.00 1.00 1.00
1.60 1.300 1.00 1.00 1.00 1.00 1.00
0.00 0.00 0.00 0.00
0.60 952.07 2704.00 0.20 35.79 272.00 1.300 1.00 1.00 1.00 1.00 1.00
1.60 1.300 1.00 1.00 100 1.00 100
0.00 0.00 0.00 0.00
0.36 571.24 2704.00 0.12 21.48 272.00
Max.•-· Deft Location in Span Load Combination Max."+" Oefl Location in Span
0.2953 4.029 0.0000 0.000
Support notation Far left is #1 Values in KIPS
Support 1 Support 2
0.370 0.370
0.160 0.160
0.210 0.210
0.210 0.210
0.370 0.370
0.210 0.210
0.330 0.330
0.210 0.210
0.210 0.210
0.330 0.330
0.210 0.210
0.126 0.126
0.210 0.210
0.210 0.210
0.126 0.126
0.210 0.210
0.160 0.160
□ □ □ □ □ □ □ □ □ □ □
ENCINA WASTEWATER AUTHORITY
INDUSTRIAL WASTEWATER DISCHARGE PERMIT
SCREENING SURVEY
6200 Avenida Encinas, Carlsbad, CA 92011
Phone: 760-438-3941 Fax: 760-476-9852
SourceControl@encinajpa.com
Date: 02/10/2021
Business Name: Pacific Western Bank ..._ • LU
Street Address: 2701 Loker Ave. San Diego, CA 92108
Email Address: ejustinscott@hhdainc.com
CITY OF CARLSBAD
BUILDING DIVISION
PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT : (ON REVERSE SIDE CHECK TYPE OF BUSINESS) I ✓ I
Check all below that are present at your facility:
Acid Cleaning D Food Processing D Metal Powders Forming
Assembly D Glass Manufacturing D Nutritional SupplementNitamin
Automotive Repair D Industrial Laundry D Manufacturing
Battery Manufacturing D Ink Manufacturing D Painting/Finishing
Biofuel Manufacturing D Laboratory D Paint Manufacturing
Biotech Laboratory D Machining/Milling D Personal Care Products
Bulk Chemical Storage D Membrane manufacturing D Manufacturing
Car Wash D (i.e. waterfilter membranes) D Pesticide Manufacturing/ Packaging
Chemical Manufacturing D Metal Casting/Forming D Pharmaceutical Manufacturing
Chemical Purification D Metal Fabrication D (including precursors)
Dental Offices D Metal Finishing D Porcelain Enameling D Dental Schools D Electroplating D Power Generation D Electroless Plating D Print Shop D Dental Clinics
D Dry Cleaning D Anodizing D Research and Development
□ Electrical Component D Coating (i.e. phosphating) D Rubber Manufacturing
□ Manufacturing D Chemical Etching/Milling D Semiconductor Manufacturing
□ Fertilizer Manufacturing D Printed Circuit Board D Soap/Detergent Manufacturing
□ Film/ X-ra y Processing D Manufacturing D Waste Treatment/Storage
New Business? YesONoE] SIC Code(s) if known: Date operation began/will begin: 06/01/2021
Tenant Improvement? Yes E] NoO If yes, briefly describe improvement: General Office to include demolition, new partitions
new electrical, new HVAC, new plumbing, new finishes, structural for HVAC only.
Description of operations generating wastewater (discharged to sewer, hauled or evaporated):_N_/A ________ _
Estimated volume of industrial wastewater to be discharged (gal/ day) : _N_/A ___________________ _
List hazardous wastes generated (type/volume):_N_i_A ___________________________ _
Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? YesD Date: _____ No[!]
Page 1 of 2
ENCINA WASTEWATER AUTHORITY
INDUSTRIAL WASTEWATER DISCHARGE PERMIT
SCREENING SURVEY
6200 Avenida Encinas, Carlsbad, CA 92011
Phone: 760-438-3941 Fax: 760-476-9852
SourceControl@encinajpa.com
The commercial enterprises listed below are a partial listing of businesses that are exempt from industrial wastewater discharge
permitting under normal operating conditions. They are exempt because (a) they discharge no process wastewater (i. e., they
only discharge sanitary wastewater with no pollutants exceeding any local limits ), and (b) they have no potential to negatively
impact the EWPCF or other wastewater treatment plants in the ESS. Any questions regarding exemptions should be referred
to EWA Source Control staff.
□ Automobile Detailer s
□ Barber/Beauty Shops
□ Business/Sales Offices
□ Cleaning Services
□ Carpet/Upholstery
□ Childcare Facilities
□ Churches
□ Community Centers
□ Consulting Services
□ Contractors
□ Counseling Services
□ Educational Services (no auto repair/film
□ Financial Institutions/Services
□ Fitness Centers
□ Gas Stations (no car wash/auto repair)
□ Grocery Stores (no film developing)
□ Residential based Businesses
developing)
□ □ □ □ □ □ □ □ [!]
□ □ □ □ □ □ □
□
Hotels/Motels (no laundry)
Laundromats
Libraries
Medical Offices (no x-ray developing)
Mortuaries
Museums
Nail Salons
Nursing Homes
Office Buildings (no process flow)
Optical Services
Pest Control Services (no pesticide repackaging for sale)
Pet Boarding/Grooming Facilities
Postal Services (no car wash/auto repair)
Public Storage Facilities
Restaurants/Bars
Retail/Wholesale Stores (no autorepair/film
developing)
Theaters (Movie/Live)
CERTIFICATION STATEMENT
I certify that the hiformation above is I rue and correct lo the best of my knowledge.
Signature: __ _,ec..,,,.,.4G~_,__--_ _,1-_-:_-_-:_-:_-:_ __ Print Name Erin Justin-Scott 02/10/2021 Date: ____ _
Kathie Hermanson Facility Contact: ___________ _ VP, Corporate Real Estate Title: ______________ _
ENCINA WASTEWATER AUTHORITY
6200AVENIDA ENCINAS, CARLSBAD, CA Phone: 760-438-3941 Fax: 760-476-9852
SourceControl@encinajpa.com
Page 2 of 2
( City of
Carlsbad
PURPOSE
CLIMATE ACTION PLAN
CONSISTENCY CHECKLIST
B-50
Development Services
Building Division
1635 Faraday Avenue
(760) 602-2719
www.carlsbadca.gov
This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance
requirements apply to their projects. Unless none of the requirements apply, the completed checklist must be
included in the building permit application. It may be necessary to supplement the completed checklist with
supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance
requirements. For example, projects that propose or require a performance approach to comply with energy-
related measures will need to attach to this checklist separate calculations and documentation as specified by
the ordinances.
,. If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required
by ordinance, an explanation must be provided to the satisfaction of the Building Official.
,. Details on CAP ordinance requirements are available on the city's website.
Project Name/Building
Permit No. Pacific Western Bank BP No. R2021-mo9
PropertyAddress/APN 2701 Loker Ave. Suites 155,235,240,250,270 Carlsbad CA 92010
Applicant Name/Co.: Erin Justin-Scott, Hurkes Harris Design Assoc.
Applicant Address 3838 Camino Del Rio N., Suite 252 San Diego, CA 92108
Contact Phone (619( 702-0380 x119 Contact Email ejustinscott@hhdainc.com
Contact information of person completing this checklist (if different than above):
Name:
Company
name/address:
Erin Justin-Scott Contact Phone:
HHDA, 3838 Camino Del Rio N, # 252 Contact Email:
San Diego, CA 92108
(619( 702-0380 x119
ejustinscott@hhdainc.com
Applicant Signature: __ ._~""""--+-¥..__.,_ __ "' _____ Date 02/10/2021
B-50 Page 1 of 3 Revised 04/19
City of Carlsbad Climate Action Plan Consistency Checklist
Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project.
For alterations and additions to existing buildings, attach Building Permit Valuation worksheet.
Buildin Permit Valuation BPV rk t· · 2. \ ·
19 -nse residential building is or more $!ones, including a 0 Residential Low-rise High-rise mixed-use building in which at least 20% of Its conditioned floor
area is residential use
□ New construction
D Additions and alterations:
□ BPV < $60,000
□ BPV" $60,000
D Electrical service panel upgrade only
□ BPV " $200,000
Nonresidential
□ New construction
BPV" $200,000 or additions" 1,00
square feet
BPV" $1,000,000
;, 2,000 sq. ft. new roof addition
1. Energy Efficiency
N/A
1A, 4A
1A, 4A'
1B, 2B,
3B, 4A
N/A
4A
18, 4A'
18, 2B, 3B, 4B and 5
All residential additions and alterations
1-2 family dwellings and townhouses with attached garages
only
'Multi-family dwellings only where interior finishes are removed
and significant site work and upgrades to structural and
mechanical, electrical, and/or plumbing systems are proposed
Building alterations of;, 75% existing gross floor area
1 B also applies if BPV;, $200,000
Please refer to Carlsbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CALGreen) for
more information when completing this section.
A D Residential addition or alteration~ $60,000 building permit valuation. □ NIA ________ _
See CMC section 18.30.190. D Exception: Home energy score~ 7
(attach oertification)
Year Built Single-family Requirements Multi-family Requirements
□ Before 1978 Select one:
C Duct sealinq [] Attic insulation [] Cool roof □ Attic insulation
□ 1978 and later Select one:
C Lighting package C Water heating Package
□ Between 1978 and 1991 Select one:
[l Duct sealing []Attic insulation □Cool roof
□ 1992 and later Select one:
Cl Lighting package □Water heating package
B. )8l Nonresidential' new construction or alterations ~ $200,000 building permit valuation,
or additions ~ 1,000 square feel □ N/A
llpdated 8115/2019 2
City of Carlsbad Climate Action Plan Consistency Checklist
See CMC 18.21.155 and CALGreen Appendix AS, Division AS.2 -Energy Efficiency.
AS.203.1.1 Choose one: Cl .1 Outdoor lighting □.2 Warehouse dock seal doors
IJ .3 Restaurant servioe water heating (comply with California Energy Code section 140.5, as amended) □ N/A ________ _
[I .4 Daylight design PAFs [I .5 Exhaust air heat recovery
AS.203.1.2.1
Choose one as applicable: 0.95 Energy budget 0,90 Energy budget □ N/A
AS.211.1"
D On-site renewable energy □ N/A
AS.211.3"
D Green power (if offered by local utility provider, 50% minimum renewable souroes) □ N/A
AS.212.1
D Elevators and escalators □ N/A
AS.213.1
□ Steel framing □ N/A
• lndudes hotels/motels and high-rise residential buildings
"For alterations~ $1,000,000 BPV and affeding > 75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comp~
\vith CMC 18.30.130 instead.
2. Photovoltaic Systems
A. D Residential new construction (for low-rise residential building permit applications submitted after 1/1/20). Refer to 2019 California
Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subjectto nonresidential photovoltaic
requirement (28 below) instead. 2) If project includes installation of an electric heat pump water heater pursuantto CMC 18.30.150(8)
(high-rise residential) or 18.30.170(8) (low-rise residential), increase system size by .3kWdc if PV offset option is selected.
Floor Plan ID (use additional CFA #d.u. Calculated kWdc'
sheets if neoessary)
Total System Size:
kWdc = (CFAx.572) / 1,000 + (1.15 x#d.u.)
'Formula calculation where CFA = conditional floor area, #du= number of dwellings per plan type
If proposed system size is less than calculated size, please explain.
Exoeption
□
□
□
□
kWdc
~onresidential new construction or alterations ~$1,000,000 8PVand affecting ~75% existing floor area, or addition that increases roof
area by ~2,000 square feel Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to
high-rise residential and hotel/motel buildings.
Choose one of the following methods:
□ Gross Floor Area (GFA) Method
GFA:
0 If< 1 O,OOOs.f. Enter 5 kWdc
Min. System Size:
~ 10,000s.f. calculate: 15 kWdc x (GFN10,000) ••
kWdc
"Round building size factor to nearest tenth, and round system size to nearest whole number.
□ Time-Dependent Valuation Method
llpdated 8115/2019 3
City of Carlsbad Climate Action Plan Consistency Checklist
Annual TDV Energy use:-* ______ x .80= Min. system size: ____ _ kWdc
... Attach calculation documentation using modeling software approved by the California Energy Commission.
3. Water Heating
A. D Residential and hotel/motel new construction
Please refer to CMC sections 18.30.150 and 18.30.170 when completing this section.
------------
□ For systems serving individual dwelling units choose one:
D Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise
residential only) D Heat pump water heater AND PV system .3 kWdc larger than required in CMC section 18.30.130 (high rise
residential hotel/motel) or CA Energy Code section 150.1 (c) 14 (low-rise residential)
D Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher
D Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors
D Exception:
D For systems serving multiple dwelling units, install a central water-heating system with all of the following:
D Gas or propane water heating system D Recirculation system per CMC 18.30.150(B) (high-rise residential, hotel/motel) or CMC 18.30.170(B) (low-
rise residential)
D Solar water heating system that is either:
□ .20 solar savings fraction
□ .15 solar savings fraction, plus drain water heat recovery
D Exception:
8, D Nonresidential new construction
Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section.
D Water heating system derives at least 40% of its energy from one of the following (attach documentation):
D Solar-thermal D Photovoltaics D Recovered energy
□Water heating system is (choose one):
□ Heat pump water heater
□ Electric resistance water heater(s)
□Solar water heating system with .40 solar savings fraction
D Exception:
Updated 8/15/2019 4
City of Carlsbad Climate Action Plan Consistency Checklist
4. Electric Vehicle Charging
A D Residential New construction and major alterations•
Please refer to Carlsbad Ordinance CMC section 18.21.140 when com letin this section.
One and two-family residential dwelling or townhouse with attached garage:
D One EVSE Ready parking space required D Exception :
D Multi family residential· -D Exception ·
Total Parking Spaces EVSE Spaces
Proposed Caoable I Readv I Installed
I I
Calculations: Total EVSE spaces= .10 x Total parking (rounded up to nearest whole number)
EVSE Installed = Total EVSE Spaces x .50 (rounded up to nearest whole number)
EVSE other-Total EVSE spaces -EVSE Installed
(EVSE other may be "Capable," "Ready'' or "Installed.')
Total
'Major alterations are: (1) for one and two-family dwellings and townhouses l'ith attached garages, alterations have a building penr,it valuation~ $60,000
or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more l'ithout attached garages), alterations have a building permit
valuation~ $200,000. interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing
systems are proposed.
B D Nonresidential new construction (includes hotels/motels) D Exception ·
Total Parking Spaces EVSE Spaces
Proposed Caoable I Readv I Installed I Total
I T I
Calculation· Refer to the table below·
Total Number of ParkinA Soaces orovided Number of r00uired EV Soaces Number of reouired EVSE Installed Spaces
D 0-9 1 1
D 10-25 2 1
D 26-50 4 2
□ 51-75 6 3
D 76-100 9 5
D 101-150 12 6
D 151-200 17 9
11 201 and over 10 percent of total 50 oercent of Reouired EV Spaces
lJ pdated 8/15/2019 5
City of Carlsbad Climate Action Plan Consistency Checklist
An approved Transportation Demand Management (TDM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT.
City staff will use the table below based on your submitted plans to determine whether or nor your permit requires a TDM plan. If TDM is applicable to your
permit, staff will contact the applicant to develop a site-specific TDM plan based on the permrt details.
Ackno~edgment:
Employee ADT Estimation for Various Commercial Uses
Use
EmpADTfor
first 1,000 s.f.
EmpADTI
1000s.f.,
Office (all), 20
Restaurant 11
Retail, 8
Industrial 4
Manufacturing 4
Warehousin 4
1 Unless otherwise noted, rates estimated from /TE Trip
Generation Manual, 10''Edition
13
11
4.5
3.5
3
1
2 For all office uses, use SAN DAG rate of 20 ADT/1,000 sf to
calculate employee ADT
, Retail uses include shopping center, variety store, supermarket,
gyms, pharmacy, etc.
Other commercial uses may be subject to special
consideration
Sample calculations:
Office: 20.450 sf
1. 20,450 sf/ 1000 x 20 = 409 Employee ADT
Retail: 9,334 sf
1. First 1,000 sf= 8 ADT
2. 9,334 sf -1,000 sf= 8,334 sf
3. 8,334 sf/ 1,000 x 4.5 + 8 = 46 Em lo ee ADT
I ackno~edge that the plans submitted may be subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should
my permit require a TDM plan and understand that an approved TDM plan is a condition of permit issuance.
Applicant Signature: _________________ _
Person other than Applicant to be contacted for TDM compliance (if applicable):
Name (Printed): __.t:,.,,_•.,_,\ (\_,__0..:::....,U='-c:-=~-''t_,_\..:...\\,-'---C',.,0,..,(~~.._, '--'' t\:._,_ __
Email Address: e.:~1.,,ut\osc o\t @,nbo.Xr\e,," mm
Updated 8/15/2019
Date: _____ _
Phone Number U)\C\-·7D2-(BY)Q
X-11°1