Loading...
HomeMy WebLinkAbout6860 AVENIDA ENCINAS; ; FA990015; PermitJob Address: Permit Type: Parcel No: Lot#: Reference No.: PC#: Project Title: Applicant: Fees($) 90 City of Carlsbad Fire Alarm Permit Permit No: FA990015 6860 AVENIDA Status: PENDING ENCINAS FALARM Applied 11/10/1999 2144501900 Approved: 0 Issued: Inspector: KAISER PERMANENTE Owner: KAISER FOUNDATION HEAL TH PLAN INC 393 E WALNUT ST PASADENA CA Add'I Fees ($) Total($) Balance($) 0 90 0 11/10/99 @ ~ --}rqq o 2 ?°r pAq°lC:OL5 ll/ro/<?9 0 Simplex SIMPLEX Time Recorder Co. 9340 Hazard Way, Suite D San Diego, CA 92123-1228 Sales: 619-279-8010 Service: 619-279-8090 Facsimile: 619-279-8164 http://www.simplexnet.com PROJECT: FIRE ALARM PRODUCT SUBMITTAL KAISER HOSPITAL CARLSBAD ORTHOPEDICS REMODEL 6860 A VENIDA ENCINAS CARLSBAD, CA 92008 REV.#: 0 PROJECT #: 970113-02 11/10/99 &Simplex SIMPLEX Time Recorder Co. 9340 Hazard Way, Suite D San Diego, CA 92123-1228 Sales: 619-279-8010 Service: 619-279-8090 Facsimile: 619-279-8164 http://www.simplexnet.com KAISER HOSPITAL CARLSBAD ORTHOPEDICS REMODEL TAB# SYSTEM 1 FIRE ALARM 2 APPENDIX REV.#: 0 PROJECT #: 970113-02 ITEM QTY. A 2 B 2 C 1 ~ I E 1 F 1 G 1 11/10/99 KAISER HOSPITAL CARLSBAD ORTHOPEDICS REMODEL FIRE ALARM SYSTEM MODEL NO. DESCRIPTION &Simplex SIMPLEX Time Recorder Co. 9340 Hazard Way, Suite D San Diego, CA 92123-1228 Sales: 619-279-8010 Service: 619-279-8090 Facsimile: 619-279-8164 http://www.simplexnet.com C.S.F.M. NO. 4098-9601 Photoelectric Smoke Detector 7272-0026:219 4098-9682 Detector Relay Base 7300-0026: 222 2098-9739 End of the Line Relays 7300-0026:013 2088 ~007 MR.101 Relay 7300-1004: 101 2088-9608 Door Holder 3550-0026:232 2088-9680 Catch Plate NIA 2088-9682 3" Extension Rod NIA REV.#: 0 PROJECT #: 970113-02 UL, ULC* Listed, FM Approved NYC, MEA Approved** i#¥0!11Ji Photoelectric smoke detector with on-board TrueAlarm sensitivity drift compensationt UL listed to standard 268 Multi-function indicator LED: • Indicates normal and alarm conditions • Provides detailed diagnostic information for service evaluation • Identifies dirty detectors, assisting with maintenance priorities Functional chamber enclosure: • Louvered design enhances smoke capture by directing flow to chamber • Entrance areas are minimally visible when ceiling mounted Magnetically operated functional test: • Initiates alarm and verifies performance • Identifies general sensitivity status using detector LED Models available in two sensitivity settings: • 4098-9601, Standard Sensitivity, nominal 2.8%/ft obscuration • 4098-9605, Special Application Sensitivity, nominal 3.5%/ft obscuration Available base options: • Bases for 2-wire or 4-wire operation • Auxiliary alarm relay output Optional remote alarm indicating LED * ULC listed models are designated with a "C" suffix such as 4098-9601C. ** Detector 4098-9601 and compatible bases are "Accepted for use -City of New York Department of Buildings-MEA35-93E". t Simplex TrueAlarm smoke detector operation is protected by one or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,543,777; 5,400,014; 5,552,765; 5,552,763; DES. 377,460. © 1999 Simplex Time Recorder Co. All rights reserved. ® TrueA/arm Smoke Detectors TrueAlarm Photoelectric Smoke Detectors for Two-Wire and Four-Wire Bases 4098-9601 TrueAlarm Photoelectric Detector Mounted in Base MJ1diffliM,i Simplex TrueAlarm photoelectric detectors provide many of the proven TrueAlarm analog sensing features for applications where detectors are connected to conventional 2-wire or 4-wire initiating device circuits (IDCs). Each TrueAlarm detector has an on-board microprocessor that evaluates its photoelectric light scattering chamber activity and makes an intelligent decision based on light obscuration history as to whether an alarm condition is present. TrueAlarm detectors are packaged in a patented housing that minimizes the visibility of the air intake louvers from the normal viewing locations while maintaining a high performance smoke capture abilityt. Bases are available for remote alarm LED indicator connections and auxiliary relay outputs. EM4YW40MIH Voltage 15 to 32 VDC, from Fire Alarm Control Panel IDC Standby Current 100 µA@24 VDC Alarm Current, 2-Wire Up to 86 mA maximum, exact current is Operation determined by alarm current limiting of connected IDC Alarm Current, 4-Wire 24 mA typical @ 24 VDC Operation Auxiliary Relay Ratings Refer to page 2 under Product Selection Air Velocity Range 0-2000 ft/min (0-610 m/min) Altitude up to 8,000 ft (2438 m) UL Listed Temp. Range 32°F to 100° F (0° C to 38° C) Operating Temp. Range 15° F to 122° F (-9° C to +50° C) Humidity Range 10% to 95% RH from 32° F to 122° F (0° C to +50° C) Color Frost White Dimensions 4 7/8" Dia. x 1 7/8" H, mounted in base (124 mm x 48 mm), refer to p.3 for detail S4098-0015-3 1 /99 ••i!tti61i,,i-i,,i·1d•ffltt4i•1ii¥li!1iii Intelligent Data Evaluation. Conventional smoke detectors will typically drift toward being too sensitive due to the accumulation of dust and dirt. With TrueAlarm analog detection, data from the photoelectric chamber is monitored and analyzed at the detector to provide a continuously shifting reference point. Drift Compensation. The data evaluation and its shifting reference point provide a software filtering process that compensates for environmental factors ( dust, dirt, etc.) and component aging, establishing an accurate reference for evaluating new activity. With this filtering, the resulting drift compensation provides a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity-either up or down. Diagnostic LED Output. Detailed service infonnation is provided by pulses that are continuously (and invisibly) encoded into the detector LED status indicator. A hand-held Smoke Detector Sensitivity Reader service tool reads this information without requiring direct contact and without initiating an alarm. Diagnostic information includes detailed detector identification and the detector's •RM·NAl-1'ttAiM,i present compensation level to assist maintenance by providing an indication of its dirt accumulation status. Magnetic Test Information. Status information is also available by performing the magnetic test and observing the detector LED pulses. The LED will normally go directly into alarm with the magnetic test. If there is an off-normal condition, the LED pulses first to indicate the condition and then goes into alarm. (See page 3.) Eili•1it+iit•1il;fflMMltaW Detector Locations. Locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFP A 72, the National Fire Alarm Code. For further detailed installation information, refer to Simplex publication 574-709, 4098 Detectors, Sensors, and Bases Application Manual. Sensitivity Selection. The 4098-9601 standard sensitivity detector is recommended for most applications. When a special application for a reduced sensitivity detector is required, the 4098-9605 should be considered. Consult Simplex for assistance in determining the proper selection. Smoke Detectors Model 4098-9601 Description TrueAlarm Photoelectric Detector Nominal Sensitivity 2.8%/ft (standard) Compatibility Compatible with detector bases: 4098-9788, 4098-9682, and 4098-9683 4098-9605 Detector Bases Model 4098-9788 4098-9682 4098-9683 Description 2-Wire Base with connections for Remote Alarm LED Indicator 4-Wire Base with Auxiliary Alarm Relay Contacts and connections for Remote LED Alarm Indicator 2-Wire Base with Auxiliary Alarm Relay & connections for Remote LED Indicator NOTE: Must be connected as the only device on the IDC to ensure relay operation. Detector Accessories Model Description 4098-9832 Adapter Plate 4098-9830 Remote LED Indicator 2098-9739 Encapsulated 24 VDC End-of-Line Relay 2098-9735 Plate Mounted 24 VDC End-of-Line Relay Simplex Time Recorder Co. 3.5%/ft Details • IDC and LED connections are screw terminals for in/out wiring, #18 to #14 AWG Relay Ratings, Single Form "C", For Suppressed Loads: • Power limited, 3 A@ 28 VDC • Non-power limited, 3 A @ 120 VAC Wiring Connections (In/Out where required): • Relay contacts and IDC wiring, color coded #18 AWG leads • LED wiring, screw terminals for #18 to #14 AWG Relay Ratings, Dual Form "C", For Suppressed Loads: • Power limited, 1 A@ 28 VDC • Non-power limited, 1/2 A@ 120 VAC Wiring Connections (In/Out where required): • Relay contacts and IDC (-), color coded #18 AWG leads • IDC (+) and LED wiring, screw terminals for #18 to #14 AWG Details • Required for mounting to 4" square box, fits 4" octagonal box • May be used when retrofitting existing bases • Compatible with 4098-9788, -9682, & -9683 detector bases • Mounted on single gang stainless steel plate • Required for 4-wire circuits using 4098-9682 base, one per circuit, select mounting type as required 2 S4098-001 5-3 1 /99 1'® n t1 • =I •l-iSi1 H ® i t+ii t•1 IH• LED Indication Flashes every 4 seconds * Status Circuit is Normal, power is applied Steady On Detector is in Alarm LED Response to Magnetic Test** LED Indication Followed By Status Action LED turns ON Normal, sensitivity is None within compensation range Flashes quickly, 6 times in More sensitive, out of 3 seconds, then turns ON Alarm is initiated normal compensation range, Cleaning or other Less sensitive, out of service is required Flashes slowly, 4 times in 8 normal compensation range seconds, then turns ON Does not initiate Alarm Detector is malfunctioning Service is required * Includes encoded diagnostic information within the LED flash. Refer to page 2 for description. ** Testing requires placing a magnet at the designated location on the detector cover for 4 seconds. Refer to application manual 574-709 for further test and maintenance information. •-1ii,MIMt•1,t¼i11·•tGMl4,Biiflt·1i,,Eiit•1il 1/4" ( 5 . 4 1 mm l _j_ =====================-6_3_18_" _( 1_6_2 _m_m_)===================== • T 1 7/8" (48 mm) l Simplex Time Recorder Co. 4098-9832 Optional Adapter Plate (required for 4" square box) ---------4 7/8" (124 mm)--------- 4098-9601 & -9605 Dimensions Mounted on Base (S) ALARM 0 &Simplex (S) V ' 4098-9830 Remote LED Indicator (not to scale) 3 Base Height 11 /16" (17 mm) S4098-0015-3 1 /99 idt•Uiliiilt·lttiMll,EiiMI• (Electrical boxes are supplied by others.) Electrical Box Requirements: Without Relay (base 4098-9788): 4" octagonal or 4" square, 1 1/2" deep; single gang, 2" deep With Relay (bases 4098-9682 and 4098-9683): 4" octagonal, 2 1/8" deep with 1 1/2" extension ring II O I IO II 4098-9832 Optional Adapter Plate (required for 4" square box) ( 4098-9682 and 4098-9683 include a relay module that mounts in base electrical box Smoke Detector Bases 4098-9682, -9683, & -9788 4098-9601, -9605 Smoke Detector Simplex, the Simplex logo, and TrueA larm are registered trademarks of Simplex Time Recorder Co. in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). S4098-0015-3 1 /99 Gardner, Massachusetts 01441-0001 USA visit us on the world wide web at www.simplexnet.com All specifications and other information shown were current as of printing and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL ~' FIRE ENGWEERm~-,;;:;: ~A~;;~1 1 s~; PROGRAM listing Expires June 30, 2000 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: 7272-0026:219 Photoelectric Smoke Detectors Simplex, 1 Simplex Plaza, Gardner, MA 01440 Contact: Paul Mattern (508) 632-2500 Page I of l Model 4098-9601, 4098-9602 and 4098-9605 photoelectric type smoke detectors. Model 4098-9602 employs an integral 135°F heat sensor. This heat sensor is intended for use as a supplemental device to the smoke detector. Refer to listee's data sheet for additional detailed system description and operational considerations. 24 VDC In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model designation, air velocity rating and UL label. Listed as photoelectric type smoke detectors for use with separately listed compatible fire alarm control units. Intended for use with listee's separately listed Models 4098- 9682, -9683 or -9788 detector base. For indoor use only. 09-25-97 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JULY 1, 1999 Effective issue date to expiration date Authorized By:~ BEN HO, Deputy State Fire Marshal III Pro1rram ManaQer CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ~ OFFICE OF THE STATE FIRE MARSHAL n~ FIRE ENGrnEERJN~,;~~ ~AT~~;~!;;; PROGRAM listing Expires June 30, 2000 LISTING No CATEGORY LISTEE: DESIGN: INSTALLATION: MARKING APPROVAL: 7300-0026 :222 Page 1 of 1 Misc. Devices/Control Unit Accessories Simplex, 1 Simplex Plaza, Gardner MA O 1440 Contact: Paul Mattern (508) 632-2500 Models 4098-9682, 4098-9683, 4098-9788 and 4098-9684 detector bases. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction Listee's name, model number, electrical rating and UL label Listed as detector bases for use with listee's separately listed compatible heat and smoke detector heads. 09-25-97 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JULY 1, 1999 Effective issue date to expiration date Authorized By: BEN HO, Deputy State Fire Marshal III Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE ST ATE FIRE MARSHAL ~ FIRE ENGmEERm~-,;;;:~A;;;~;s~m; PROGRAM listing Expires June 30, 2000 LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING APPROVAL: 7300-0026:013 Misc. Devices/Control Unit Accessories Simplex Time Recorder Co., 1 Simplex Plaza, Gardner MA 01440 Contact: Paul Mattern (508) 632-2500 Page 1 of 1 Models 2098-9735, 2098-9736 and 2098-9739 end-of-line relays; Model 4293-24 end- of-line resistor; and Models 2098-9737, 2098-9738 and 2098-9827 relay modules. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number and UL label. Listed as control unit accessories *for use with separately listed compatible detector bases and fire alarm control units. *Rev. I 0-23-95 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued:JUL Y 1, 1999 Effective issue date to expiration date Authorized By: BEN HO, Deputy State Fire Marshall III ProITTam ManaQer Multi-Application Peripherals and Accessories UL Listed (Air Products) Miscellaneous Devices, Control Relays Track Mounted/Encapsulated 4098-9843 and 2088 Series FEATURES • UL listed as control unit accessory • Track mount package availability: -Single or four relay module, with or without enclosure, with SPOT or DPDT contacts -LED indicates relay coil status Enclosures provide status LED viewing ports -Multiple coil voltage inputs, diode polarized -Modules are track mounted with "Snap-Apart" feature design • Single encapsulated SPOT relay package with color coded #18 AWG wire leads, available in two versions: -2088-9021 Provides diode polarized multiple input voltage ability and LED indication -4098-9843 Provides a diode polarized 24 VDC coil with In/Out wiring SPECIFICATIONS (refer to page 2 for dimensions) Track Mount Relays Contact Ratings 10 A@ 115 VAe, resistive Coil Voltage 18-35 VAeNOe, 115, or 230 VAe Coil Current • SPOT models = 15 mA • OPOT models = 35 mA Terminal Block Ratings up to# 14 AWG Encapsulated Relays Connections I# 18 AWG color-coded wire leads 2088-9021 Contact Ratings 10 A@ 115 VAe, resistive Voltage 18-35 VAeNoe, 115, or 230 VAe Coil Ratings Current 15 mA@ 24 VAeNoe, 115, or 230 VAe 4098-9843 Coil Ratings 18-35 voe input, 15 mA @ 24 voe • 10 A @ 115 VAe Contact Ratings • 1 A@28 voe • 250 µA @ 5 voe General Specifications (all models) Temperature Range j -58° F to 185° F (-50° e to 85° e) © 1999 Simplex Time Recorder Co. All rights reserved. • Model 2088-9020, Four OPOT Relay Package with Enclosure (shown with cover removed) Encapsulated Relay Package (typical of 2088-9021 and 4098-9843) DESCRIPTION These multi-purpose control relays offer SPOT or OPOT, 10 Amp contacts in a variety of mechanical packages. Models are available for coil operation by one of four input voltages allowing a single relay to be energized from a voltage source of 18-35 VOC or VAC, 115 VAC, or 230 VAC (not available with 4098-9843). Voltage selection is made by wiring to the appropriate input terminals. Each relay model (except model 4098-9843) contains a red LED which indicates that the relay coil is energized. Mounting options are varied for application flexibility. Track mounted relays may be "snapped apart" from a standard four-module assembly and used independently if desired. S2088-001 0-6 2/99 RELAY SELECTION CHART > -,,_ Product ID Model Relay Relay Packaging Dimensions Type Quantity ~ -- 2088-9007 MR-101/T SPOT 3" H x 2 1 /8" W x 1 1 /2" D 2088-9009 MR-201/T Track mount, without enclosure (76 mm x 54 mm x 38 mm) DPDT 2088-9008 MR-101/C SPOT Single 6 1 /8" H x 3 1 /4" W X 2 1 /2" D Track mount with enclosure (156 mm x 83 mm x 64 mm) 2088-9010 MR-201/C DPDT 2088-9017 MR-104/T SPOT 3" H x 8 1 /2" W x 1 1 /2" D 2088-9019 MR-204/T Track mount, without enclosure (76 mm x 216 mm x 38 mm) DPDT Four 2088-9018 MR-104/C SPOT 6 1 /8" H x 9 1 /2" W x 2 1 /2" D Track mount with enclosure (156 mm x 241 mm x 64 mm) 2088-9020 MR-204/C DPDT Encapsulated, multi-voltage coil, color 1 1 /2" H x 1" W x 7 /8" D 2088-9021 PAM-1 coded #18 AWG wire leads, with coil (38 mm x 25.4 mm x 22 mm) SPOT Single status LED 4098-9843 PAM-SD Encapsulated, 24 VDC coil, color 1 1/2" H X 1 3/16" W X 13/16" D coded #18 AWG wire leads (no LED) (38 mm x 30 mm x 21 mm) TRACK MOUNT RELAY WIRING REFERENCE SPOT contacts rated 10 A@ 115 VAC, resistive I I l®®®®I ® 0 18/24 115 230 ® (18-35) voe Coil voltage (note polarity (18-35) VAC for DC) 115VAC 230 VAC I I I I (-) (+) AC AC N V V V Terminal strip connections SPOT models DPDT contacts rated 10 A@ 115 VAC, resistive Relay energized LED ® C NO NC C NO DJ I I l®®®®I ® 0 18/24 115 230 ® (18-35) voe Coil voltage (note polarity (18-35) VAC for DC) 115 VAC 230 VAC I I I I (-) (+) AC AC N V V V Terminal strip connections DPDT models Simplex and the Simplex logo are registered trademarks of the Simplex Time Recorder Co. S2088-0010-6 2/99 Gardner, Massachusetts 01441-0001 U.S. A. Offices and Representatives Throughout the World Visit us on the world wide web at www.simplexnet.com. All specifications and other information shown were current as of printing and are subject to change without notice. 06/21/1999 13:05 LISTING No. 'CATEGORY: LISTEE: DESIGN: INSTALLATION; MARKING: APPROVAL: 2483328807 AIR PRODUCTS CALIFOR~IA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE ST ATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTI NG SERVICE 7300-1004: 101 Misc. Device/Control Unit Accessories Air Products & Controls, 1749 East Highwood, Pontiac, Ml 48340 Contact: Daniel Klein (248) 332-3900 PAGE 01/01 Listing ExpirM June 30, 2000 Page 1 of 1 Models MR-101/C, MR-104/C, MR-201/C, •MR-201/CX, MR-204/C, •MR- 204/CX, PAM-1, PAM-2, PAM-2X, PAM-3, PAM~4, •RJC-1 and •RJC-2 relay modules. Models MR-101 IC, -201 IC and -201 /CX may employ suffix -R or -s. Refer to listee 's aata sheet for detailed product description and operational considerations. In accordance with listee's printed installation instruction, applicable codes & ordinances and in a manner ·acceptable to the authority having jurisdiction. Listee's name, electrical rating and UL labeJ. Listed as relay modules for use with separately listed compatible control units. • Rev. 10-15-98 This listing is based upon technical dar... submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other dara but does not make an independent verification of: any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to Jistee's data sheec, installation instructions and/or other suitable information sources. )ate Issued: JULY 1, 1999 Effective issue dace to expiration date Authorized By~~ BEN HO, Deputy State Fire Marshal Ill Program Manager UL Listed 1#¥\hilii Electromagnetic door holders with wall mount models available for: • Flush mount for low profile applications • Semi-flush mount for shallow box applications • Surface mount Low current, multi-voltage design reduces power supply and battery demands: • Operates with 24 VDC, 24 V AC, or 120 V AC • Current requirement is 15 mA at rated voltage Internal full wave rectifier allows AC or DC operation and provides switching transient suppression Low residual magnetism allows easy door release for compatibility with low pressure door closers Quick and easy installation: • Self-adjusting swivel catch-plate has two pivot points to adjust to door alignment changes • Adhesive mounting templates assure alignment Holding force is 25 lbs minimum Optional accessories: • Extension rods of 1" or 3" • Back plate for reinforced door mounting M419iffl1Mli Door holders are normally energized to provide door holding with a minimum force of 25 lbs. In the event of a fire, the fire alarm control panel or other compatible control means will release the magnet allowing the door to close to prevent the spread of smoke. Doors may be manually opened when the door holder is energized. © 1999 Simplex Time Recorder Co. All rights reserved. Fire Alarm System Accessories Electromagnetic Door Holders for Flush, Semi-Flush, or Surface Mount Semi-Flush Mount Door Holder Magnet and Catch Plate (shown with screw hole caps in place) EM49otffiOM,H Mechanical Specifications Material Finish Durable die-cast metal Double chrome plated, decorative surfaces are textured Three position terminal block with provisions Wiring Connections for in/out wiring (common, low voltage, high voltage) Ground Connection # 18 AWG wire lead, 9" minimum Electrical Specifications Input Voltage Terminals Current 24VDC C&L 24VAC 15 mA 120 VAC C&H S2088-0013 2/99 •AM·t!Af.11ttAiMII Door Holders, Voltage Selectable as 24 VDC, 24 VAC, or 120 VAC Model 2088-9607 2088-9608 2088-9609 Description Flush mount, includes magnet, catch plate, cover, and 3" (76 mm) chrome extension rod Semi-flush mount, includes semi-flush magnet and cover assembly, catch plate, and screw hole caps Surface mount, includes semi-flush magnet and cover assembly, catch plate, and matching electrical box Optional Door Holders Accessories Description Electrical Box Requirement Single gang box, 2 1/2" deep minimum (supplied by others) Single gang box, 2" deep minimum (supplied by others) Surface mount box is supplied with door holder, dimensions: 4 5/8" H x 2 3/4" W x 2 1/8" D (117 mm x 70 mm x 54 mm) Model 2088-9680 Back plate for reinforcing catch plate, mounts on opposite side of door 2088-9681 Catch plate extender rod, 1" (25.4 mm) long 2088-9682 Catch plate extender rod, 3" (76 mm) long (supplied with 2088-9607) ~ 23/4" __J I · (70 mm) · I . l 3 5/16" @ 4 5/8" (8-4~m_m_) -~---:·· __._ \ .. Jm) Semi-Flush and Surface Mount Front View Simplex Time Recorder Co. 1" (25 mm) 1 1/8" (29 mm) Semi-Flush Side View 2 1" (25mm) 2 1/8" __J (54 mm) -, l 4 5/8" (117 mm) ,.__.________,J Surface Mount Side View (conduit entries are supplied on top, bottom, and back) S2088-0013 2/99 H11:J:IM•tlittmll1',t•hiliii1u6i·1itA••11i,i41Mt·1,tW 3 5/16" (84 mm) I.--23/4" __J I · (70 mm) · I 4 5/8" (117mm) Flush Mount Front View 1.--115/16" l;1 (49 mm) Flush Mount Side View 1efflAIIUffit1•1i,,t41MMlti€WE•1fPGdhei¥t3,111€i•11€iii4i#11MN■ _______________ _ Simplex Time Recorder Co. r 2" _ _I (51 mm) I T -, ---------j 2" (51 mm) _L Pivot swivel Screw holes 2 112,, 1 3/4" (44 mm) (64 mm) I l Threaded rod extensions insert here 3 S2088-0013 2/99 f11M=lta=11l•MiMIFi•=ffllMffltl 1.---2 3/8" -----.J I (60 mm) I ~ ~ 3/16" I ,--(5 mm) 7/8" (22 mm) + 1 3/4" (44 mm) 3/4" (19 mm) Simplex and the Simplex logo are registered trademarks of Simplex Time Recorder Co. in the U.S. and/or other countries. S2088-0013 2/99 Gardner, Massachusetts 01441-0001 USA visit us on the world wide web at www.simplexnet.com All specifications and other information shown were current as of printing and are subject to change without notice. L LISTING No. CATEGORY: LISTEE: DESIGN: RATING: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LIS TING SERVICE 3550-0026:232 Door Closer/Holders/Releasing Devices Simplex, Simplex Plaza, Gardner, MA 01441 -0001 Contact: Paul Mattern (978) 874-8542 listing Expires June 30, 2000 Page 1 of I Models 2088-9608, 2088-9608C, 2088-9609, 2088-9609C, 2088-9607, and 2088-9607C door holders. These door holders consist of electromagnetic assemblies housed in either listed outlet boxes or secured within aluminum or zinc cover plates. Refer to listee's data sheet for detailed product description and operational considerations. 12 VAC, 24 V AC, 120 V AC, 240 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. The units are intended to be flush, recessed or surface mounted to the adjacent wall surface. MARKING: APPROVAL: XLF: Listee's name, model number, electrical rating, load rating, and UL label, Listed as door holders for use on swinging type fire doors where permitted per codes. For indoor use only. 3550-1459:112 03-01-99 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JULY 1, 1999 Effective issue date to expiration date Authorized By: . ~ ~O, Deputy State Fire Marshal III ProPT~m M~n~P-P.r 11/10/99 ITEM A B APPENDIX REV.#: 0 &Simplex SIMPLEX Time Recorder Co. 9340 Hazard Way, Suite D San Diego, CA 92123-1228 Sales: 619-279-8010 Service: 619-279-8090 Facsimile: 619-279-8164 http://www.simplexnet.com DESCRIPTION BUSINESS LISCENCE SIMPLEX WARRANTY PROJECT #: 970113-02 jhdc of Q.Ialifornia @nntrartnrs jtate 1Jlirenttr.· 16lnar0 ,-----, -~C<'-< lll-24 (REV. 4-91) 91 62972 Pursuant to Chapter 9 of Division 3 of the Business and Professions Code and the Rules and Regulations of the Contractors State License Board, the Registrar of Contractors does hereby issue this license to: SIMPLEX TIME RECORDER CO to engage in the business or act in the capacity of a contractor in the following classification(s): re of License Qua I ifier I< 111£ C,-1(:. CIO -ELECTRICAL (GENERAL) Ct6 -FIRE PROTECTION CONTRACTOR Witness my hand and seal this day, April 11, 1996 Issued August 18, 1992 CERTIFIED COPY This license is the property of the Registrar of Contractors, is not transferrable, and shall be returned to the Registrar upon demand when suspended, revoked, or invalidated for any reason. It becomes void if not renewed. ~ teof Callfomla Department of Consumer Affairs 652487 License Number -----_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ -_ ---=--=--=------_-_ -_-_-_-_-------------------______ ·:.=-=:--=~---------=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=-~~ AUOIT NO 138106 &Simplex SIMPLEX WARRANTY 9340 Hazard Way, Suite D3 San Diego, CA 92123 Sales (858) 279-8010 Service (858) 249-8090 Fax (858) 279-8164 WARRANTY & DAMAGES: Simplex hereby warranties for one (1) year from the date of beneficial use or eighteen (18) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty is made to the purchaser of this equipment and is in lieu of all other warranties, express or implied, including any implied warranty of merchantability of fitness for a particular purpose. Simplex shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. This warranty is solely limited to the equipment as provided by Simplex in this submittal and excludes associated field wiring and/or any equipment to which the submitted equipment may be attached or connected. WARRANTY SERVICE HOURS: -8:00 TO 17:00, MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED SIMPLEX HOLIDAYS. -OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST.