HomeMy WebLinkAbout1855 ARTEMISIA CT; ; CBC2021-0031; PermitPERMIT REPORT (city of Carlsbad Commercial Permit Print Date: 05/23/2022 Job Address: 1855 ARTEMISIA CT, CARLSBAD, CA Permit Type: BLDG-Commercial Parcel#: Valuation: $18,605.97 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Work Class: Patio Track#: Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Permit No: CBC2021-0031 Status: Closed -Finaled Applied: 01/28/2021 Issued: 03/11/2021 Finaled Close Out: 05/20/2022 Inspector: Final Inspection: PB urn 05/20/2022 Description: POINSETTIA 61 (TREVISO): REC AREA -SHADE STRUCTURES, BBQ ISLAND AND FIRE TABLE Applicant: Property Owner: LENNAR HOMES ALAN CHIK 15131 ALTON PKWY, # 365 IRVINE, CA LENNAR HOMES OF CALIFORNIA INC 15131 ALTON PKWY, # UNIT 365 IRVINE, CA 92618-2385 (949) 204-4628 FEE BUILDING PERMIT FEE ($2000+) STRONG MOTION-COMMERCIAL (949) 204-4628 PLUMBING BLDG COMMERCIAL NEW/ADDITION/REMODEL BUILDING PLAN CHECK FEE (BLDG) SB1473 GREEN BUILDING STATE STANDARDS FEE BUILDING PLAN REVIEW-MINOR PROJECTS (LDE) BUILDING PLAN REVIEW -MINOR PROJECTS (PLN) Total Fees: $678.35 Total Payments To Date: $386.35 Contractor: LENNAR HOMES OF CALIFORNIA INC 15131 ALTON PKWY, # UNIT 365 IRVINE, CA 92618-2385 (949) 204-4628 Balance Due: AMOUNT $194.79 $5.21 $49.00 $136.35 $1.00 $194.00 $98.00 $292,00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction.'1 You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov (city of Carlsbad COMMERCIAL BUILDING PERMIT APPLICATION B-2 Plan Check('£{ N ()4 / -003) Est. Value b-/!f, f?x"0-c; 9-- PC Deposit ---~--~-- Date _ __,_'74/,,,:c}'-6£.__,1,.._f ::Jz...,/f-- Poinsettia 61 (Treviso) Job Address ___________________ Suite: _____ APN: __________ _ Rec Center (1855 Artemisia) CT 14-10 Tenant Name: _______________ CT/Project #: _______________ Lot#:. ___ _ Occupancy: Rec Center and Upper Parkconstruction Type: ____ Fire Sprinklers: yes/ no Air Conditioning: yes/ no BRIEF DESCRIPTION OF WORK: I) Shade Structure (Upper Park). 2) Shade Structure (Rec Center). 3) BBQ Island (Rec Center). 4) Shade Structure (Rec Center Lookout). 5) Fire Table (Rec Center Lookout). D Addition/New: ___________ .New SF and Use, ___________ N,ew SF and Use, ____ Deck SF, Patio Cover SF (not including flatwork) LJ Tenant Improvement: ______ SF, _____ SF, Existing Use ______ Proposed Use ______ _ Existing Use Proposed Use ______ _ □ Pool/Spa: _____ SF Additional Gas or Electrical Features? ____________ _ D Solar: ___ KW, __ Modules, ___ Mounted, Tilt: Yes/ No, RMA: Yes/ No, Panel Upgrade: Yes/ No l) BBQ Island (Rec Center): Gas line, GFCI outlet. 1(] Plumbing/Mechanical/Electrical Only: 2) Fire Table (Rec Center Lookout): Gas Line. 2(1 Other: Structural: I) Shade Structure (Upper Park): 381.6 SF. 2) Shade Structure (Rec Center): 745.5 SF. 3) Shade Structure (Rec Center Lookout): 381 .6 SF. APPLICANT (PRIMARY) PROPERTY OWNER Name: _ ... J"",eJJown..,aJ..r..1.H.co.,.mw,.e..,s ___________ Name: ----'L"'e'-'n'"n"'a"'r---'H'-""o"'m"'e"'s'------------- Address: 15131 Alton Parkway, Suite 365 Address: _:cl.:..5.:..13=--l=--=--A:::lt:..::o.:..n=--P=--a=r.:..k:.:.w:..:a:.i.y.:..., .:..Su=i:.:te=--=.3.::.6=..5 _____ _ City: Irvine State: CA Zip: 92618 City: Irvine State: CA Zip: _92_6_1_8 __ Phone: (949) 204-4628 Phone: _ _:(~94_9-'-)=2~04=-~4~6-28 __________ _ Email: Alan.Chik@Lennar.com Email: __ A_l_a_n_.C_h_,_·k_@_L_en_n_ar_._co_m _________ _ DESIGN PROFESSIONAL Name: Duane Stroobosscher Address: 4429 Morena Blvd. City: San Diego State: CA Zip: 92117 Phone: (858) 866-8544 Email: des@utilityspecialists.com Architect State License: ___________ _ CONTRACTOR BUSINESS Name: __ J1..e10ou.ou.a.i..ru::Hu.oum=es"------------- Address: _,_l,,_51..,3,_,l'--'A~l'-'to"'n"---'-P-"'ar'-'k"w-'-'a!Jy"-, .,,.Su"'i"'te"--"'36s,,5"------- City: Irvine State: CA Zip: _9~2~6_1~8 ___ _ Phone: _.,_(9_4_9'--) 2=-0=--4=---4.:..6:..:2:..:8 __________ _ Email: Alan.Chik@Lennar.com State License: 728102 Bus. License: BLOS1239643 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 B-2 Ph: 760-602-2719 Fax: 760-602-8558 Page 1 of 2 Email: Building@carlsbadca.gov Rev. 06/18 ( OPTION A): WORKERS'COMPENSATION DECLARATION; I hearby affirm under penalty af perjury one of the following declarations: DI have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. □ I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: _____________________ _ Policy No. ______________ Expiration Date: __________ _ □ Certificate of Exemption: I certify that in the performance of the work for wtiich this permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation laws of California. WARNING: Failure to secure workers compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. □AGENT DATE: CONTRACTOR SIGNATURE: ----------------------------- ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractors License law for the following reason: □ !, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure ls not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such Improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). C{I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). □ I am exempt under Section _______ Business and Professions Code for this reason: 1. l personally plan to provide the major tabor and materials for construction of the proposed property improvement. □ Yes □ No 2. ! (have/ have not) signed an application fo~buifding permit for the proposed work. 3. I have contracted with the following petSO (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, b have hir e following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): 5. I will provide some of the work, but I the following persons to provide the work indicated (include name/ address/ ph()Oe / type of work): DATE: _1_12~0_12_0_21 __ _ CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name; ____________________ _ Lender's Address: ____________________ _ ONLY COMPLETE THE FOUOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley"Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No IS the facility to be constructed within 1,000 feet of the outer boundary of a scliool site? □ Yes □ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I ti ave read the application and state that tlie above information is correct and that the information on the plans is accurate. I agree to comply witli all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL UAB!UTI • JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGA!NSTSAID CITY IN CONSEQUENCE OF THE GRANT!NG OF THIS PERMIT.OSHA: An OSHA permi s required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Off!(:' by such permit is not commenced within 180 days after the work is commenced for a period of 180 1635 Faraday Ave Carlsbad, B-1 ions of this Code shall expire by limitation and become null and void if the building or work authorized permit or if the building or work authorized by such permit is suspended or abandoned at any time u 'orm Bullding Code]. Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of2 Email: Building@carlsbadca.gov Rev. 06/18 ' . ' . PERMIT INSPECTION HISTORY for (CBC202~-0031) Permit Type: BLDG-Commercial Work Class: Patio Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date Checklist Item BLDG-Structural Final BLDG-Structural Final BLDG-Electrical Final Monday, May 23, 2022 Application Date: 01/28/2021 Issue Date: 03/11/2021 Owner: LENNAR HOMES OF CALIFORNIA INC Subdivision: Expiration Date: 09/27/2021 IVR Number: 31242 Address: 1855 ARTEMISIA CT CARLSBAD,CA Inspection No. Inspection Status Primary Inspector Reinspection Inspection COMMENTS July 23, 2020: 1. Outstanding correction items for pool building and bathroom areas, cabana areas, fire piVfire table-partial approval. 2. B-59 waste management form received-filed in city Records. 3. Pool house building, bathroom areas, and open beam patio structure, per structural engineer's plans and detail specifications -pending final approval. a) Pending: fire pit/fire table unit installed {on back order). 4. Public community pool house restroom, ADA compliant, per architectural plans and detail specifications -approved. July 21, 2020: 1. Outstanding correction items for pool bathroom areas and Porcher cabana areas. Inform superintendent Jesse regarding correction items. July 23, 2020: 1. Outstanding correction items for pool building and bathroom areas, cabana areas, fire pit/fire table-partial approval. 2. B-59 waste management form received-filed in city Records. 3. Pool house building, bathroom areas, and open beam patio structure, per structural engineer's plans and detail specifications -pending final approval. a) Pending: fire pit/fire table unit installed {on back order). 4. Public community pool house restroom, ADA compliant, per architectural plans and detail specifications -approved. Passed Yes No Yes Page 3 of 3 ~,1•,;3;,<~ 0 l" PERMl:'F lNSPECTlQN HlSTOR'Yi for (CBQ~0:21-0031) Permit Type: BLDG-Commercial Work Class: Patio Status: Closed -Finaled Scheduled Date 05/20/2022 Actual Inspection Type Start Date Checklist Item BLDG-Plumbing Final BLDG-Structural Final BLDG-Structural Final BLDG-Electrical Final 05/20/2022 BLDG-Final Inspection Monday, May 23, 2022 Application Date: 01/28/2021 Issue Date: 03/11/2021 Expiration Date: 09/27/2021 Owner: LENNAR HOMES OF CALIFORNIA INC IVR Number: 31242 Subdivision: Address: 1855 ARTEMISIA CT CARLSBAD, CA Inspection No. Inspection Status Primary Inspector Reinspection Inspection COMMENTS July 23, 2020: 1. Outstanding correction items for pool building and bathroom areas, cabana areas, fire piUfire table-partial approval. 2. 8-59 waste management form received-filed in city Records. 3. Pool house building, bathroom areas, and open beam patio structure, per structural engineer's plans and detail specifications -pending final approval. a) Pending: fire piUfire table unit installed (on back order). 4. Public community pool house restroom, ADA compliant, per architectural plans and detail specifications -approved. July 23, 2020: 1. Outstanding correction items for pool building and bathroom areas, cabana areas, fire piUfire table-partial approval. 2. 8-59 waste management form received-filed in city Records. 3. Pool house building, bathroom areas, and open beam patio structure, per structural engineer's plans and detail specifications -pending final approval. a) Pending: fire piUfire table unit installed (on back order). 4. Public community pool house restroom, ADA compliant. per architectural plans and detail specifications -approved. July 21, 2020: 1. Outstanding correction items for pool bathroom areas and Porcher cabana areas. Inform superintendent Jesse regarding correction items. July 23, 2020: 1. Outstanding correction items for pool building and bathroom areas, cabana areas, fire piUfire table-partial approval. 2. 8-59 waste management form received-filed in city Records. 3. Pool house building, bathroom areas, and open beam patio structure, per structural engineer's plans and detail specifications -pending final approval. a) Pending: fire piUfire table unit installed (on back order). 4. Public community pool house restroom, ADA compliant, per architectural plans and detail specifications -approved. 183240-2022 Passed Tony Alvarado Passed Yes Yes No Yes Complete Page 2 of 3 Building Permit Inspection History Finaled ( City of Carlsbad PERMIT INSPECTION HISTORY for (CBC2021-0031) Permit Type: BLDG-Commercial Application Date: 01/28/2021 Owner: LENNAR HOMES OF CALIFORNIA INC Work Class: Patio Issue Date: 03/11/2021 Subdivision: Status: Closed -Finaled Expiration Date: 09/27/2021 Address: 1855 ARTEMISIA CT IVR Number: 31242 CARLSBAD,CA Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 03/16/2021 03/16/2021 BLDG-11 152808-2021 Passed Paul Burnette Complete Foundation/Ftg/Piers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-12 Steel/Bond 152809-2021 Passed Paul Burnette Complete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 0313012021 0313012021 BLDG-66 Grout 153828-2021 Passed Paul Burnette Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 07121/2021 07121/2021 BLDG-Final Inspection 162470-2021 Failed Tony Alvarado Reinspection Incomplete Checklist Item COMMENTS Passed BLDG-Plumbing Final July 21, 2020 No 1. Outstanding correction items for pool bathroom areas and Porcher cabana areas. Inform superintendent Jesse regarding correction items. BLDG-Structural Final July 21 , 2020 No 1. Outstanding correction items for pool bathroom areas and Porcher cabana areas. Inform superintendent Jesse regarding correction items. BLDG-Electrical Final July 21, 20W No 1. Outstanding correction items for pool bathroom areas and Porcher cabana areas. Inform superintendent Jesse regarding correction items. 07123/2021 0712312021 BLDG-Final Inspection 162693-2021 Partial Pass Tony Alvarado Reinspection Incomplete Monday, May 23, 2022 Page 1 of 3 DATE: 3-10-2021 JURISDICTION: Carlsbad PLAN CHECK#.: CBC2021-0031.RC2 PROJECT ADDRESS: Poinsettia 61 ✓• EsG1I SET III 0 APPLICANT 0 JURIS. PROJECT NAME: Landscape Improvement for Poinsettia 61 -Production Ph 3 iz;J The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: iz;J EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone Date contacted: (by: ) Mail Telephone Fax In Person 0 REMARKS: By: Erich A. Kuchar, P.E. (For S.C.) EsGil Email: Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 DATE: 3-1-2021 JURISDICTION: Carlsbad PLAN CHECK#.: CBC2021-0031.RC1 PROJECT ADDRESS: Poinsettia 61 ✓• EsG1I SET: II □ APPLICANT □ JURIS. PROJECT NAME: Landscape Improvement for Poinsettia 61 -Production Ph 3 D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: D EsGil staff did not advise the applicant that the plan check has been completed. ~ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Alan Chik Telephone#: (949) 204-4628 Date contacted: (by: ) Mail Telephone Fax In Person 0 REMARKS: By: Erich A. Kuchar, P.E. (For S.C.) EsGil Email: alan.chik@lennar.com Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBC2021-0031.RC1 3-1-2021 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. Please make all corrections, as requested in the correction list. Submit THREE sets of plans for residential projects. For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. PLANS 1. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). Signatures on the final sets of plans will be verified before they are approved. All sheets that were resubmitted were missing signatures. All sheets must be stamped and signed on resubmittal. STRUCTURAL 2. Shade Structures: Provide structural calculations for pilasters and footing size for lateral force (wind and seismic force load combinations) included. Plan sets received were missing all structural engineering sheets from the first submittal. Upon resubmittal make sure ALL SHEETS ARE SUBMITTED. Complete sets of plans will be reviewed next submittal for conformance and structural comments will be checked with stamped and signed sheets. MISCELLANEOUS 3. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. • Carlsbad CBC2021-0031.RC1 3-1-2021 4. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ 5. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Erich A. Kuchar, P.E. (For S.C.) at EsGil. Thank you. l'Of)>j -Rf-\-~~( a.._ DATE: 2-12-2021 JURISDICTION: Carlsbad PLAN CHECK#.: CBC2021-0031 PROJECT ADDRESS: Poinsettia 61 EsGil SET: I □ APPLICANT □ JURIS. PROJECT NAME: Landscape Improvement for Poinsettia 61 -Production Ph 3 D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [:8J The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: D EsGil staff did not advise the applicant that the plan check has been completed. [:8J EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Alan Chik Telephone#: (949) 204-4628 Date contacted: Mail Telephone 0 REMARKS: By: Soon Cho EsGil (by: ) Email: alan.chik@lennar.com Fax In Person Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBC2021-0031 2-12-2021 PLAN REVIEW CORRECTION LIST LANDDSCAPE PLAN PLAN CHECK#.: CBC2021-0031 PROJECT ADDRESS: Poinsettia 61 FLOOR AREA: REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 2-12-2021 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad STORIES: HEIGHT: DATE PLANS RECEIVED BY ESGIL CORPORATION: - PLAN REVIEWER: Soon Cho This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2019 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2018 IRC, 2018 IBC, 2018 UPC, 2018 UMC and 2017 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2018 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBC2021-0031 2-12-2021 Please make all corrections, as requested in the correction list. Submit THREE sets of plans for residential projects. For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. PLANS 1. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). Signatures on the final sets of plans will be verified before they are approved. 2. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2019 California Building Code, which adopts the 2018 IBC, 2018 UMC, 2018 UPC and the 2017 NEC. under general notes on the first sheet of the plans. 3. LC-1.02 & LC-1.04: Show and delineate accessible path of travel, including minimum width, slope, cross-slope, etc. from street to all shade structures. 4. Walks and sidewalks shall have a continuous common surface, not interrupted by steps or by abrupt changes in level exceeding ½ inch. (1113A.1) 5. LC-5.02: Exterior stairs shall have the upper approach and all treads marked by a stripe providing clear visual contrast. (1115A.5) 6. LC-2.01: Show accessible seating at shade structure and eating area. 7. LC-2.02: Provide accessible seating where benches are provided. 8. LC-2.02: Provide accessible area at shade structures. STRUCTURAL 9. Shade Structures: Provide structural calculations for pilasters and footing size for lateral force (wind and seismic force load combinations) included. Carlsbad CBC2021-0031 2-12-2021 10. Sign wall: Provide wall details and size of footing and engineering calcs for sign wall and footing. Include lateral forces. 11. Footing : Provide standard hook details. MISCELLANEOUS 12. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 13. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ 14. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Soon Cho at EsGil. Thank you. Carlsbad CBC2021-0031 2-12-2021 [DO NOT PAY -THIS IS NOT AN INVOICE] JURISDICTION: Carlsbad PREPARED BY: BUILDING ADDRESS: BUILDING OCCUPANCY: BULDING AREA PORTION {Sq.Fl) Remodel Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb I 1997 USC Building Permit fee ~ t t'H .~.i:: I 1997 USC Plan Check FH t "/\1 .f~ · i] VALUATION AND PLAN CHECK FEE Valuation Reg. M.lliplier Mod. By Ordinance PLAN CHECK#.: CBC2021-0031 DATE: 2-12-2021 VALUE {$) 1 , Type of Review: r Complete Review r Structural Only r Repetitive Fee " 8 Repeats ,, ,, r Other r Hourly EsG■Fee ,, B Hrs.@• $126.37, Sheet 1 of 1 GOUVIS nuineerinu consulting group, inc. PROJECT NO: PROJECT NAME: CLIENT NAME: 65370 POINSETTIA 61 MODEL HOMES LENNAR GENERAL NOTES & SPECIFICATIONS: 1 ALL DESIGN IS PER 2019 CBC Date 10/7/2020 SHADE STRUCTURE 2 FOOTING SHALL BEAR AGAINST FIRM, NATURAL UNDISTURBED SOIL OR CERTIFIED COMPACTED FILL 3 CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2500 psi. SPECIAL INSPECTION IS NOT REQUIRED. 4 REINFORCING SHALL BE DEFORMED BARS PER ASTM A-615. #3&#4 BARS MAY BE GRADE 40, #5 AND LARGER BARS SHALL BE GRADE 60 SOILS REPORT: SOI LS ENG INEER = REPORT#= SOILS REPORT DATE= PASSIVE PRESSURE = SOI L BEARING PRESSURE = GROUP DELTA SD412 11/20/2014 300 psf 2000 psf PER SECTION 1806.3.4, passive pressure can be increased due to short term load SEISMIC: V=0.3* Sos* W Sos= 0.79 ROOF/TRELLIS MEMBER MEMBER SIZE COUNT 6X12 BEAM 4X10 JOIST CMU PILASTER TOTAL WEIGHT = # OF POST: 2 11 4 LATERAL LOAD @ EACH POST: V= W (INCH) H (INCH) L (FEET) WEIGHT 5.5 11.5 21.5 35 pcf 3.5 9.5 21.5 35 pcf 16 16 10 130 pcf Total Wt 661.05 1911.30 9244.44 0.00 0.00 0.00 0.00 0.00 11816.79 4.00 2954.20 700.14 G Gouvis Engineering 15 Studebaker Irvine, Ca 92618 Printed: 6 OCT 2020, 8:58AM Wood Beam File = N:165370\Landscape_Shade Structure\Trellislcalcs\65370-Trellis.e<:6 . Software copyright ENERCALC, INC. 1983-2020, Build:12.20.2.28 . DESCRIPTION: 6x12 beam CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 201 8 Material Properties . . Analysis Method : Allowable Stress Design Load Combination IBC 2018 Fb+ Fb- 1,000.0 psi 1,000.0 psi 1,000.0psi 1,000.0 psi E : Modulus of Elasticity Wood Species Wood Grade Fc -Prll Fe -Perp Fv Ft Beam Bracing : Beam is Fully Braced against lateral-torsional buckling • 0(0.07) E(0.07) • 6x12 ¼ 6x12 Span= 3.750 ft Span = 14.0 ft 65.0 psi 65.0psi • Ebend-xx 1,300.0ksi Eminbend -xx 1,300.0ksi Density 34.0pcf ¼ 6x12 Span= 3.750 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 2 Uniform Load : D = 0.010, E = 0.010 ksf, Tributary Width= 7.0 ft DESIGN SUMMARY Maximum Bending Stress Ratio 0.189 1 Maximum Shear Stress Ratio 0.172: 1 Section used for this span 6x12 Section used for this span 6x1 2 = 169.75psi 10.06 psi = 900.00psi 58.50 psi Load Combination +O+H Load Combination +O+H Location of maximum on span = 6.941 ft Location of maximum on span = 3.750 ft Span # where maximum occurs = Span #2 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.068 in Ratio= 2482>=360 Max Upward Transient Deflection -0.057 in Ratio= 1572>=360 Max Downward Total Deflection 0.115 in Ratio = 1460>=180 Max Upward Total Deflection -0.097 in Ratio= 924>=180 ------------ Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span# M V Cd C FN Ci Cr Cm Ct CL M fb F'b V fv F'v +O+H 0.00 0.00 0.00 0.00 Length = 3.750 ft 0.172 0.90 1.000 1.00 1.00 1.00 1.00 1.00 900.00 0.42 10.06 58.50 Length= 14.0 ft 2 0.189 0.172 0.90 1.000 1.00 1.00 1.00 1.00 1.00 1.71 169.75 900.00 0.42 10.06 58.50 Length = 3.750 ft 3 0.172 0.90 1.000 1.00 1.00 1.00 1.00 1.00 900.00 0.00 10.06 58.50 +O+L+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length= 3.750 ft 1 0.155 1.00 1.000 1.00 1.00 1.00 1.00 1.00 1000.00 0.42 10.06 65.00 Length= 14.0 ft 2 0.170 0.155 1.00 1.000 1.00 1.00 1.00 1.00 1.00 1.71 169.75 1000.00 0.42 10.06 6500 Length = 3.750 ft 3 0.155 1.00 1.000 1.00 1.00 1.00 1.00 1.00 1000.00 0.00 10.06 65.00 +D+Lr+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 3.750 ft 1 0.124 1.25 1.000 1.00 1.00 1.00 1.00 1.00 1250.00 0.42 10.06 81.25 Length = 14.0 ft 2 0.136 0.124 1.25 1.000 1.00 1.00 1.00 1.00 1.00 1.71 169.75 1250.00 0.42 10.06 81.25 Length = 3.750 ft 3 0.124 1.25 1.000 1.00 1.00 1.00 1.00 1.00 1250.00 0.00 10.06 81.25 +D+S+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 G Gouvis Engineering 15 Studebaker Irvine, Ca 92618 Printed: 6 OCT 2020, 8:58AM Wood Beam File= N:165370\Landscape_Shade Structure\Trellislcalcs\65370-Trellis.ec6 . Software copyright ENERCALC, INC. 1983-2020, Build:12.20.2.28 . 1,1111' • DESCRIPTION: 6x12 beam Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span# M V Cd CFN Ci Cr Cm Ct CL M fb F'b V fv F'v Length = 3.750 ft 1 0.135 1.15 1.000 1.00 1.00 1.00 1.00 1.00 1150.00 0.42 10.06 74.75 Length = 14.0 ft 2 0.148 0.135 1.15 1.000 1.00 1.00 1.00 1.00 1.00 1.71 169.75 1150.00 0.42 10.06 74.75 Length = 3.750 ft 3 0.135 1.15 1.000 1.00 1.00 1.00 1.00 1.00 1150.00 0.00 10.06 74.75 +0.0.750Lr+0.750L +H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length= 3.750 ft 1 0.124 1.25 1.000 1.00 1.00 1.00 1.00 1.00 1250.00 0.42 10.06 81.25 Length= 14.0 ft 2 0.136 0.124 1.25 1.000 1.00 1.00 1.00 1.00 1.00 1.71 169.75 1250.00 0.42 10.06 81.25 Length = 3.750 ft 3 0.124 1.25 1.000 1.00 1.00 1.00 1.00 1.00 1250.00 0.00 10.06 81.25 +0.0. 750L .0. 750S+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 3.750 ft 1 0.135 1.15 1.000 1.00 1.00 1.00 1.00 1.00 1150.00 0.42 10.06 74.75 Length= 14.0 ft 2 0.148 0.135 1.15 1.000 1.00 1.00 1.00 1.00 1.00 1.71 169.75 1150.00 0.42 10.06 74.75 Length = 3.750 ft 3 0.135 1.15 1.000 1.00 1.00 1.00 1.00 1.00 1150.00 0.00 10.06 74.75 +0+0.60W+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length= 3.750 ft 1 0.097 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1600.00 0.42 10.06 104.00 Length = 14.0 ft 2 0.106 0.097 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1.71 169.75 1600.00 0.42 10.06 104.00 Length = 3.750 ft 3 0.097 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1600.00 0.00 10.06 104.00 +D.0.70E+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length= 3.750 ft 1 0.164 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1600.00 0.72 17.10 104.00 Length= 14.0 ft 2 0.180 0.164 1.60 1.000 1.00 1.00 1.00 1.00 1.00 2.92 288.57 1600.00 0.72 17.10 104.00 Length = 3.750 ft 3 0.164 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1600.00 0.00 17.10 104.00 +0.0. 750Lr.0. 750L .0.450W+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length= 3.750 ft 1 0.097 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1600.00 0.42 10.06 104.00 Length= 14.0 ft 2 0.106 0.097 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1.71 169.75 1600.00 0.42 1006 104.00 Length= 3.750 ft 3 0.097 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1600.00 0.00 10.06 104.00 +0.0. 750L +O. 750S+0.450W+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length= 3.750 ft 1 0.097 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1600.00 0.42 10.06 104.00 Length= 14.0 ft 2 0.106 0.097 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1.71 169.75 1600.00 0.42 10.06 104.00 Length= 3.750 ft 3 0.097 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1600.00 0.00 10.06 104.00 +0+-0. 750L +O. 750S+0.5250E+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length= 3.750 ft 1 0.147 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1600.00 0.65 15.34 104.00 Length= 14.0 ft 2 0.162 0.147 1.60 1.000 1.00 1.00 1.00 1.00 1.00 2.62 258.87 1600.00 0.65 15.34 104.00 Length= 3.750 ft 3 0.147 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1600.00 0.00 15.34 104.00 +0.60D+0.60W.0.60H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length= 3.750 ft 1 0.058 1.60 1.000 1.00 1.00 1.00 1.00 1.00 160000 0.25 6.03 104.00 Length= 14.0 ft 2 0.064 0.058 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1.03 101.85 1600.00 0.25 6.03 104.00 Length= 3.750 ft 3 0.058 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1600.00 0.00 6.03 104.00 +0.60D+0.70E+0.60H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length= 3.750 ft 1 0.126 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1600.00 0.55 13.08 104.00 Length= 14.0 ft 2 0.138 0.126 1.60 1.000 1.00 1.00 1.00 1.00 1.00 2.23 220.67 1600.00 0.55 13.08 104.00 Length = 3.750 ft 3 0.126 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1600.00 0.00 13.08 104.00 Overall Maximum Deflections Load Combination Span Max.·-• Defl Location in Span Load Combination Max."+" Defl Location in Span 1 0.0000 0.000 +D+0.70E+H -0.0973 0.000 +0+0.70E+H 2 0.1150 7.059 0,0000 0.000 3 0.0000 7.059 +D+0.70E+H -0.0973 3.750 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support3 Support 4 Overall MAXimum 0.833 0.833 Overall MINimum 0.490 0.490 +O+H 0.490 0.490 +O+L+H 0.490 0.490 +O+Lr+H 0.490 0.490 +O+S+H 0.490 0.490 +D.0.750Lr+0.750L +H 0.490 0.490 +D.0.750L +0.750S+H 0.490 0.490 +0+0.60W+H 0.490 0.490 +D+0.70E+H 0.833 0.833 +D+0. 750Lr+O. 750L +0.450W+H 0.490 0.490 +0+0.750L+0.750S+0.450W+H 0.490 0.490 G Gouvis Engineering 15 Studebaker Irvine, Ca 92618 Wood Beam DESCRIPTION: 6x12 beam Vertical Reactions Load Combination +D-+-0. 750[-+-0. 750S-+-0.5250E-iH -+0.60O-+0.60W-+0.60H -+0.60O-+0. 70E-+0.60H DOnly Lr Only LOnly SOnly WOnly E Only H Only Support 1 Printed: 6 OCT 2020, 8:58AM File= N:165370\Landscape_Shade Structure\Trellis\calcs\65370-Trellis.ec6 . Software copyright ENERCALC, INC. 1983-2020, Build:12.20.2.28 . . - Support notation : Far left is #1 Values in KIPS Support 2 Support 3 Support 4 0.747 0.747 0.294 0.294 0.637 0.637 0.490 0.490 0.490 0.490 G Gouvis Engineering 15 Studebaker Irvine, Ca 92618 General Footing 1.1111• DESCRIPTION: SHADE STRUCTURE Code References Calculations per ACI 318-14, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used : IBC 2018 General Information Material Properties fc : Concrete 28 day strength fy : Rebar Yield Ee : Concrete Elastic Modulus Concrete Density <p Values Flexure Shear Analysis Settings Min Steel % Bending Reinf. Min Allow % Temp Rein!. Min. Overturning Safety Factor Min. Sliding Safety Factor Add Fig Wt for Soil Pressure Use fig wt for stability, moments & shears Add Pedestal Wt for Soil Pressure Use Pedestal wt for stability, mom & shear Dimensions Width parallel to X-X Axis Length parallel to Z-Z Axis Footing Thickness Pedestal dimensions ... px : parallel to X-X Axis pz : parallel to Z-Z Axis Height = = = = Rebar Centerline to Edge of Concrete ... at Bottom of footing = Reinforcing Bars parallel to X-X Axis Number of Bars Reinforcing Bar Size Bars parallel to Z-Z Axis Number of Bars = Reinforcing Bar Size = Bandwidth Distribution Check (ACI 15.4.4.2) Direction Requiring Closer Separation # Bars required within zone # Bars required on each side of zone Applied Loads P : Column Load OB : Overburden M-xx M-zz V-x V-z = = 2.50 ksi = 60.0 ksi 2,850.0 ksi 145.0 pct 0.90 = 0.750 = 0.00180 = 1.10 : 1 = 1.10 : 1 Yes Yes No No 3.50 ft 3.50 ft 12.0 in 16.0 in 16.0 in 76.0 in 3.0 in 5.0 # 5 5.0 # 5 n/a n/a n/a D Lr 3.0 Printed: 7 OCT 2020, 10:30AM File= N:165370\Landscape_Shade Structure\Trellis\calcs\65370-Trellis.ec6 . Software copyright ENERCALC, INC. 1983-2020, Build:12.20.2.28 . . . Soil Design Values Allowable Soil Bearing = 2.0 ksf Increase Bearing By Footing Weight = No Soil Passive Resistance (for Sliding) 300.0 pct Soil/Concrete Friction Coeff. = 0.350 Increases based on footing Depth Footing base depth below soil surface = 2.0 ft Allow press. increase per foot of depth = ksf when footing base is below = ft Increases based on footing plan dimension Allowable pressure increase per foot of depth when max. length or width is greater than z X ~ ~ 1'-V IWl~~••l L s w = u-~•"' E 0.710 0.710 H ksf ft k ksf k-ft k-ft k k Printed: 7 OCT 2020, 10:30AM G Gouvis Engineering 15 Studebaker Irvine, Ca 92618 File= N:\65370\Landscape_Shade Structure\Trellis\calcs\65370-Trellis.ec6 . Software copyright ENERCALC, INC. 1983-2020, Build:12.20.2.28 . General Footing .. , .... . . DESCRIPTION: SHADE STRUCTURE _________________________________ __...--.t¥iH,C-U..._ DESIGN SUMMARY Min. Ratio Item PASS 0.4948 Soil Bearing PASS 1.708 Overturning • X-X PASS 1.708 Overturning -Z-Z PASS 5.674 Sliding -X-X PASS 5.674 Sliding· Z-Z PASS n/a Uplift PASS 0.03388 Z Flexure (+X) PASS 0.01113 Z Flexure (-X) PASS 0.03388 X Flexure (+Z) PASS 0,01113 X Flexure (-Z) PASS 0.04917 1-way Shear (+X) PASS 0.01431 1-way Shear (·X) PASS 0.04917 1-way Shear (+Z) PASS 0.01431 1-way Shear (-Z) PASS 0.01861 2-way Punching Detailed Results Soll Bearing Rotation Axis & Load Combination ... Gross Allowable X-X, +D+H 2.0 X-X, +D+L+H 2.0 X-X, +D+Lr+H 2.0 X-X, +D+S+H 2.0 X-X, +0+0.750Lr+O. 750L +H 2.0 X-X, +0+0.750L +0.750S+H 2.0 X-X, +D+0.60W+H 2.0 X-X, +D+0.70E+H 2.0 X-X, +0+0.750Lr+0.750L +0.450W+H 2.0 X-X, +0+0.750L +0.750S+0.450W+H 2.0 X-X, +0+0.750L +0.750S+0.5250E+H 2.0 X-X, +0.60D+0.60W+0.60H 2.0 X-X, +0.60D+0.70E+0.60H 2.0 Z-Z, +D+H 2.0 Z-Z, +D+L+H 2.0 Z-Z, +D+Lr+H 2.0 Z-Z, +D+S+H 2.0 Z-Z, +D+0.750Lr+0.750L +H 2.0 Z-Z, +0+0.750L +O. 750S+H 2.0 Z-Z, +D+0.60W+H 2.0 Z-Z, +D+0.70E+H 2.0 Z-Z, +0+0.750Lr+0.750L +0.450W+H 2.0 Z-Z, +0+0.750L +O. 750S+0.450W+H 2.0 Z-Z, +D+0.750L +0.750S+0.5250E+H 2.0 Z-Z, +0.60D+0.60W+0.60H 2.0 Z-Z, +0.60D+0.70E+0.60H 2.0 Overturning Stability Rotation Axis & Load Combination ... X-X, +D+H X-X, +D+L+H X-X, +D+Lr+H X-X, +D+S+H X-X, +D+0.750Lr+0.750L +H X-X, +D+0.750L+0.750S+H X-X, +D+0.60W+H X-X, +D+0.70E+H X-X, +D+0.750Lr+0.750L +0.450W+H X-X, +D+0.750L +0.750S+0.450W+H Applied 0.9896 ksf 3.645 k-ft 3.645 k-ft 0.4970 k 0.4970 k 0.0 k 0.5725 k-ft/ft 0.1881 k-ft/ft 0.5725 k-ft/ft 0.1881 k-ft/ft 3.688 psi 1.073 psi 3.688 psi 1.073 psi 2.792 psi Xecc Zecc (in) n/a 0.0 n/a 0.0 n/a 0.0 n/a 0.0 n/a 0.0 n/a 0.0 n/a 0.0 n/a 7.378 n/a 0.0 n/a 0.0 n/a 5.533 n/a 0.0 n/a 12.296 0.0 n/a 0.0 n/a 0.0 n/a 0.0 n/a 0.0 n/a 0.0 n/a 0.0 n/a 7.378 nla 0.0 n/a 0.0 nla 5.533 n/a 0.0 n/a 12.296 n/a Overturning Moment None None None None None None None 3.645 k-ft None None Capacity 2.0 ksf 6.225 k-ft 6.225 k-ft 2.820 k 2.820 k 0.0 k 16.897 k-ft/ft 16.897 k-ft/ft 16.897 k-ft/ft 16.897 k-ft/ft 75.0 psi 75.0 psi 75.0 psi 75.0 psi 150.0 psi Governing Load Combination +0+0.70E+H about Z-Z axis +0.60D+0.70E+0.60H +0.60D+0.70E+0.60H +0.60D+0.70E+0.60H +0.60D+0.70E+0.60H No Uplift +0.7420D+E+0.90H +1.40D+1.60H +0.7420D+E+0.90H + 1.40D+ 1.60H +0.7420D+E+0.90H +1.358D+0.50L +O. 70S+E+1.60H +0.7420D+E+0.90H +1.358D+0.50L +O. 70S+E+1.60H +1.40D+1.60H Actual Soll Bearing Stress i Location Actual / Allow Bottom, -Z Top, +Z Le , -X Right, +X Ratio 0.4839 0.4839 n/a n/a 0.242 0.4839 0.4839 n/a n/a 0.242 0.4839 0.4839 n/a n/a 0.242 0.4839 0.4839 n/a n/a 0.242 0.4839 0.4839 n/a n/a 0.242 0.4839 0.4839 n/a n/a 0.242 0.4839 0.4839 n/a n/a 0.242 0.0 0.9896 n/a n/a 0.495 0.4839 0.4839 n/a n/a 0.242 0.4839 0.4839 n/a n/a 0.242 0.1052 0.8626 n/a n/a 0.431 0.2904 0.2904 n/a n/a 0.145 0.0 0.9266 n/a n/a 0.463 n/a n/a 0.4839 0.4839 0.242 n/a n/a 0.4839 0.4839 0.242 n/a n/a 0.4839 0.4839 0.242 n/a n/a 0.4839 0.4839 0.242 n/a n/a 0.4839 0.4839 0.242 n/a n/a 0.4839 0.4839 0.242 n/a nla 0.4839 0.4839 0.242 n/a n/a 0.0 0.9896 0.495 n/a n/a 0.4839 0.4839 0.242 n/a n/a 0.4839 0.4839 0.242 n/a n/a 0.1052 0.8626 0.431 n/a n/a 0.2904 0.2904 0.145 n/a n/a 0.0 0.9266 0.463 Resisting Moment Stability Ratio Status 0.0 k-ft Infinity OK 0.0 k-ft Infinity OK 0.0 k-ft Infinity OK 0.0 k-ft Infinity OK 0.0 k-ft Infinity OK 0.0 k-ft Infinity OK 0.0 k-ft Infinity OK 10.374 k-ft 2.846 OK 0.0 k-ft Infinity OK 0.0 k-ft Infinity OK Gouvis Engineering 15 Studebaker Irvine, Ca 92618 General Footing DESCRIPTION: SHADE STRUCTURE Overturning St_ability Rotation Axis & Load Combination ... ---··· X-X, +D+0.750L +0.750S+0.5250E+H X-X, +0.60D+0.60W+0.60H X-X, +0.60D+0.70E+0.60H Z-Z, +D+H 2-Z, +D+L+H Z-Z, +D+Lr+H 2-Z, +D+S+H Z-Z, +D+0.750Lr+0.750L+H Z-Z, +D+0.750L+0.750S+H Z-Z, +D+0.60W+H Z-Z, +D+0.70E+H Z-Z, +D+0.750Lr+0.750L +0.450W+H Z-Z, +D+0.750L+0.750S+0.450W+H Z-Z, +D+0.750L +0.750S+0.5250E+H Z-Z, +0.60D+0.60W+0.60H Z-Z, +0.60D+0.70E+0.60H Sliding Stability Force Application Axis Load Combination ... X-X, +D+H X-X, +D+L+H X-X, +D+Lr+H X-X, +D+S+H X-X, +D+0.750Lr+0.750L+H X-X, +D+0.750L +0.750S+H X-X, +D+0.60W+H X-X, +D+0.70E+H X-X, +D+0.750Lr+0.750L+0.450W+H X-X, +D+0.750L+0.750S+0.450W+H X-X, +D+0.750L +0.750S+0.5250E+H X-X, +0.60D+0.60W+0.60H X-X, +0.60D+0.70E+0.60H Z-Z, +D+H Z-Z, +D+L+H Z-Z, +D+Lr+H Z-Z, +D+S+H Z-Z, +D+0.750Lr+0.750L+H Z-Z, +D+0.750L +0.750S+H Z-Z, +D+0.750L +0.750S+0.450W+H Z-Z, +D+0.750L +0.750S+0.5250E+H Z-Z, +0.60D+0.60W+0.60H Z-Z, +0.60D+0.70E+0.60H Z-Z, +D+Q.60W+H Z-Z, +D+0.70E+H Z-Z, +D+0.750Lr+0.750L +0.450W+H Footing Flexure Flexure Axis & Load Combination Mu k-ft X-X, +1.40D+1.60H 0.1881 X-X, +1.40D+1.60H 0.1881 X-X, +1.20D+0.50Lr+1.60L+1.60H 0.1612 X-X, +1.20D+0.50Lr+1.60L+1.60H 0.1612 X-X, +1.20D+1.60L +0.50S+1.60H 0.1612 X-X, +1.20D+1.60L+0.50S+1.60H 0.1612 X-X, +1.20D+1.60Lr+0.50L +1.60H 0.1612 X-X, + 1.20D+1.60Lr+0.50L +1.60H 0.1612 X-X, +1.20D+1.60Lr+0.50W+1.60H 0.1612 X-X, +1.20D+1.60Lr+0.50W+1.60H 0.1612 X-X, +1.20D+0.50L+1.60S+1.60H 0.1612 X-X, +1.20D+0.50L+1.60S+1.60H 0.1612 Overturning Moment 2.734 k-ft None 3.645 k-ft None None None None None None None 3.645 k-ft None None 2.734 k-ft None 3.645 k-ft Sliding Force 0.0 k 0.0 k 0.0 k 0.0 k 0.0 k 0.0 k 0.0 k 0.4970 k 0.0 k 0.0 k 0.3728 k 0.0 k 0.4970 k 0.0 k 0.0 k 0.0 k 0.0 k 0.0 k 0.0 k 0.0 k 0.3728 k 0.0 k 0.4970 k 0.0 k 0.4970 k 0.0 k Side Tension Surface +Z Bottom -Z Bottom +Z Bottom -Z Bottom +Z Bottom -Z Bottom +Z Bottom -Z Bottom +Z Bottom -Z Bottom +Z Bottom -Z Bottom Printed: 7 OCT 2020, 10:30AM File= N:\65370\Landscape_Shade Structure\Trellislcalcs\65370-Trellis.ec6 . Software copyright ENERCALC, INC. 1983-2020, Build:12.20.2.28 . . . Resisting Mo~ent Stability Ratio Status 10.374 k-ft 3.795 OK 0.0 k-ft Infinity OK 6.225 k-ft 1.708 OK 0.0 k-ft Infinity OK 0.0 k-ft Infinity OK 0.0 k-ft Infinity OK 0.0 k-ft Infinity OK 0.0 k-ft Infinity OK 0.0 k-ft Infinity OK 0.0 k-ft Infinity OK 10.374 k-ft 2.846 OK 0.0 k-ft Infinity OK 0.0 k-ft Infinity OK 10.374 k-ft 3.795 OK 0.0 k-ft Infinity OK 6.225 k-ft 1.708 OK All units k Resisting Force Stability Ratio Status 3.650 k No Slidino OK 3.650 k No Slidino OK 3.650 k No Slidino OK 3.650 k No Slidino OK 3.650 k No Slidino OK 3.650 k No Slidino OK 3.650 k No Slidinq OK 3.650 k 7.344 OK 3.650 k No Slidino OK 3.650 k No Slidino OK 3.650 k 9.792 OK 2.820 k No Slidino OK 2.820 k 5.674 OK 3.650 k No Slidinq OK 3.650 k No Slidinq OK 3.650 k No Slidino OK 3.650 k No Slidino OK 3.650 k No Slidino OK 3.650 k No Slidino OK 3.650 k No Slidino OK 3.650 k 9.792 OK 2.820 k No Slidino OK 2.820 k 5.674 OK 3.650 k No Slidinq OK 3.650 k 7.344 OK 3.650 k No Slidino OK As Req'd Gvrn. As Actual As Phi*Mn Status in112 in112 in112 k-ft 0.2592 Min Temp% 0.4429 16.897 OK 0.2592 Min Temp% 0.4429 16.897 OK 0.2592 Min Temp% 0.4429 16.897 OK 0.2592 Min Temp% 0.4429 16.897 OK 0.2592 Min Temp% 0.4429 16.897 OK 0.2592 Min Temp% 0.4429 16.897 OK 0.2592 Min Temp% 0.4429 16.897 OK 0.2592 Min Temp% 0.4429 16.897 OK 0.2592 Min Temp% 0.4429 16.897 OK 0.2592 Min Temp% 0.4429 16.897 OK 0.2592 Min Temp% 0.4429 16.897 OK 0.2592 Min Temp% 0.4429 16.897 OK Gouvis Engineering 15 Studebaker Irvine, Ca 92618 General Footing 1,1111' DESCRIPTION: SHADE STRUCTURE Footing_Flexure Flexure Axis & Load Combination Mu k-ft X-X, +1.20D+1.60S<-0.50W+1.60H 0.1612 X-X, +1.20D+ 1.60S<-0.50W+1.60H 0.1612 X-X, +1.20D<-0.50Lr<-0.50L +W+1.60H 0.1612 X-X, +1.20D<-0.50Lr<-0.50L +W+1.60H 0.1612 X-X, +1.20D<-0.50L <-0.50S+W+1.60H 0.1612 X-X, +1.20D<-0.50L <-0.50S+W+1.60H 0.1612 X-X, +1.358D<-0.50L <-0.70S+E+1.60H 0.5234 X-X, +1.358D<-0.50L <-0.70S+E+1.60H 0.1534 X-X, <-0 90D+W<-0.90H 0.1209 X-X. <-0 90D+W<-O 90H 0.1209 X-X, <-0.7420D+E<-0.90H 0.5725 X-X, <-0.7420D+E<-0.90H 0.1110 Z-Z, +1.40D+1.60H 0.1881 Z-Z, +1.400+1.60H 0.1881 Z-Z, +1.200<-0.50Lr+1.60L+1.60H 0.1612 Z-Z, +1.200<-0.50Lr+1.60L+1.60H 0.1612 Z-Z, +1.200+1.60L <-0.50S+1.60H 0.1612 Z-Z, +1.200+ 1.60L <-0.50S+1.60H 0.1612 Z-Z, +1.200+1.60Lr<-0.50L+1.60H 0.1612 Z-Z, +1.200+1.60Lr<-0.50L+1.60H 0.1612 Z-Z, +1.200+1.60Lr<-0.50W+1.60H 0.1612 Z-Z, +1.200+1.60Lr<-0.50W+1.60H 0.1612 Z-Z, + 1.200<-0.50L +1.60S+1.60H 0.1612 Z-Z, +1.200<-0.50L +1.60S+1.60H 0.1612 Z-Z, +1.200+1.60S<-0.50W+1.60H 0.1612 Z-Z, +1.200+1.60S<-0.50W+1.60H 0.1612 Z-Z, +1.200<-0.50Lr<-0.50L +W+1.60H 0.1612 Z-Z, +1.200<-0.50Lr<-0.50L +W+1.60H 0.1612 Z-Z, +1.200<-0.50L <-0.50S+W+1.60H 0.1612 Z-Z, +1.200<-0.50L <-0.50S+W+ 1.60H 0.1612 Z-Z, +1.3580<-0.50L <-0.70S+E+ 1.60H 0.1534 Z-Z, +1.3580<-0.50L <-0.70S+E+ 1.60H 0.5234 Z-Z. <-0.900+W<-0.90H 0.1209 Z-Z, <-0.900+W<-0.90H 0.1209 Z-Z, <-0.74200+E<-0.90H 0.1110 Z-Z, <-0.74200+E<-0.90H 0.5725 One Way Shear Side +Z -Z +Z -Z +Z -Z +Z -Z +Z -Z +Z -Z -X +X -X +X -X +X -X +X -X +X -X +X -X +X -X +X -X +X -X +X -X +X -X +X Printed: 7 OCT 2020, 10·30AM File; N:\65370\Landscape_Shade Structure\Trellis\calcs\65370-Trellis.ec6 . Software copyright ENERCALC, INC. 1983-2020, Build:12.20.2.28 . . . Tension As Req'd Gvrn. As Actual As Phi*Mn Status Surface in"-2 in"2 in"-2 k-ft Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Top 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Top 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Top 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Top 0.2592 Min Temp% 0.4429 16.897 OK Bottom 0.2592 Min Temp% 0.4429 16.897 OK Load Combination ... Vu@•X Vu@+X Vu@•Z Vu@+Z Vu:Max PhiVn Vu/ Phi'Vn Status +1.400+1.60H 1.04 psi 1.04 psi 1.04 psi 1.04 psi 1.04psi 75.00 psi 0.01 OK +1.200<-0.50Lr+1.60L +1.60H 0.89psi 0.89psi 0.89 psi 0.89 psi 0.89 psi 75.00 psi 0.01 OK +1.200+1.60L <-0.50S+ 1.60H 0.89 psi 0.89psi 0.89 psi 0.89 psi 0.89 psi 75.00 psi 0.01 OK +1.20D+1.60Lr<-0.50L +1.60H 0.89 psi 0.89 psi 0.89 psi 0.89 psi 0.89 psi 75.00 psi 0.01 OK + 1.200+1.60Lr<-0.50W+ 1.60H 0.89 psi 0.89 psi 0.89 psi 0.89 psi 0.89 psi 75.00 psi 0.01 OK + 1.200<-0.50L +1.60S+1.60H 0.89 psi 0.89 psi 0.89 psi 0.89 psi 0 89 psi 75.00 psi 0.01 OK + 1.200+ 1.60S<-0.50W+ 1.60H 0.89 psi 0.89 psi 0.89 psi 0.89 psi 0.89psi 75.00 psi 0.01 OK + 1.200<-0.50Lr<-0.50L +W+1.60H 0.89 psi 0 89 psi 0.89 psi 0.89 psi 0.89psi 75.00 psi 0.01 OK + 1.200<-0.50L <-0.50S+W+1.60H 0.89 psi 0 89 psi 0.89 psi 0.89 psi 0.89 psi 75.00 psi 0.01 OK + 1.3580<-0.50L <-0. 70S+E+ 1.60H 1.07 psi 3.14psi 1.07 psi 3.14 psi 3.14psi 75.00 psi 0.04 OK <-0.900+W<-0.90H 0.67 psi 0.67 psi 0.67 psi 0.67 psi 0.67 psi 75.00 psi 0.01 OK <-0.7 4200+E<-0.90H 0.61 psi 3.69psi 0.61 psi 3.69 psi 3.69 psi 75.00 psi 0.05 OK Two-Way "Punching" Shear All units k .. Load Combination ... Vu Phi*Vn Vu/ Phi'Vn Status +1.400+1.60H 2.79 psi 150 OOpsi 0.01861 OK + 1.200<-0.50Lr+1.60L +1.60H 2.39 psi 150 OOpsi 0.01595 OK + 1.200+ 1.60L <-0.50S+1.60H 2.39 psi 150.00psi 0.01595 OK +1.200+ 1.60Lr<-0.50L +1.60H 2.39 psi 150.00psi 0.01595 OK +1.200+1.60Lr<-0.50W+1.60H 2.39 psi 150.00psi 0.01595 OK +1.200<-0.50L +1.60S+1.60H 2.39 psi 150.00psi 0.01595 OK +1.200+1.60S<-0.50W+ 1.60H 2.39 psi 150.00psi 0.01595 OK +1.200<-0.50Lr<-0.50L +W+1.60H 2.39 psi 150.00psi 0.01595 OK Gouvis Engineering 15 Studebaker Irvine, Ca 92618 General Footing 1,1111' DESCRIPTION: SHADE STRUCTURE Two-Way "Punching" Shear Load Combination ... +1.200+-0.50L +-0.50S+W+1.60H + 1.3580+-0.50L +-0. 70S+E+ 1.60H +-0.90D+W+-0.90H +-0.7 420D+E+-0.90H Vu 2.39 psi 2.72 psi 1.80 psi 2.23 psi Phi*Vn 150.00psi 150.00psi 150.00psi 150.00psi Printed: 7 OCT 2020, 10:30AM File= N:\65370\Landscape_Shade Structure\Trellis\calcs\65370-Trellis.ec6 . Software copyright ENERCALC, INC. 1983-2020, Build:12.20.2.28 . Vu/ Phi*Vn 0.01595 0.01812 0.01197 0.01484 . . All units k Status OK OK OK OK