HomeMy WebLinkAboutCD 2020-0010; T-MOBILE SD06088A; Administrative DeterminationTO OBTAIN LOCATION OF PARTICIPANTS
UNDERGROUND FACILITIES BEFORE
YOU DIG IN CALIFORNIA (SOUTH), CALL
DIG ALERT
TOLL FREE: 1-800-227-2600 OR
www.digalert.org
Know what's below,
Call before you dig.
CALIFORNIA STATUTE
REQUIRES MIN OF 2
WORKING DAYS NOTICE
BEFORE YOU EXCAVATE •
CITY OF CARLSBAD
Administrative Permit
ExibitNo.''A"-"f"\." Date "?:/3/J,a'Lo
SITE NUMBER: SD06088A
LAS FLORES
ROOFTOP
CITY: CARLSBAD
SITE NAME:
SITE TYPE:
SHT DRAWING INDEX
T1 TITLE SHEET
T2 GENERAL NOTES
A1 SITE PLAN
A2 ENLARGED SITE PLAN & EQUIPMENT PLAN
A3 ANTENNA PLANS
A4 NORTHEAST ELEVATIONS
A5 SOUTHEAST ELEVATIONS
A6 SOUTHWEST ELEVATIONS
A7 NORTHWEST ELEVATIONS
A8 RFDS PLUMBING DIAGRAM
01 DETAILS
G1 GROUNDING NOTES & PLAN
G2 GROUNDING DETAILS
APPROVALS:
PRINT NAME SIGNATURE
LAND OWNER:
DEVELOP. MANAGER
CONST. MANAGER
PROJECT MANAGER:
ZONING MANAGER:
TMO RF ENGINEER:
SAC. REP:
CONST. MANAGER
GENERAL CONTRACTOR NOTES
DO NOT SCALE DRAWINGS
SUBCONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL
IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE
WORK OR BE RESPONSIBLE FOR SAME.
REV
0
0
0
0
0
0
0
0
0
0
0
0
0
DATE
COUNTY: SAN DIEGO
JURISDICTION: CITY OF CARLSBAD
~ri
fllS:
nts
VICINITY MAP
CODE COMPLIANCE
PER CALIFORNIA BUILDING STANDARDS CODE, ''TITLE 24 OF THE CALIFORNIA CODE OF
REGULATIONS" GOVERNS THE DESIGN AND CONSTRUCTION OF ALL BUILDING OCCUPANCIES AND
ASSOCIATED FACILITIES AND EQUIPMENT THROUGHOUT CALIFORNIA. RELEVANT CODE
SECTIONS ARE (BUT NOT LIMITED TO):
1. 2016 CALIFORNIA BUILDING CODE
2. 2016 CALIFORNIA ELECTRICAL CODE
3. 2016 CALIFORNIA ENERGY CODE
4. 2016 CALIFORNIA HISTORICAL BUILDING CODE
5. 2016 CALIFORNIA FIRE CODE
6. 2016 CALIFORNIA EXISTING BUILDING CODE
7. CITY/COUNTY ORDINANCES
8. ANSlfTIA-222-G-2005
~--fi-!Ci! "" ~ '•'4
,:;:J --,
NORTH
L600 SCOPE OF WORK: (RFDSVERSION DATE: 04-12-19)
MODIFICATION OF AN EXISTING 'T-MOBILE' TELECOMMUNICATION FACILITY CONSISTING OF THE FOLLOWING:
SCOPE (AS DEPICTED IN RFDS)
• INSTALL (2) NEW 4' PANEL ANTENNAS, (1) PER SECTOR A & B
• INSTALL (1) NEW 6' PANEL ANTENNAS, (1) PER SECTOR C
• INSTALL (3) NEW RRU 4449 NEAR ANTENNAS (B12+B71), (1) PER SECTOR
• REPLACE (1) EXISTING DUL WITH (2) NEW BB6630
• INSTALL (6) NEW LOOSE DC CABLES AND (6) NEW LOOSE FIBER CABLES
• REPLACE (1) EXISTING FRP SCREEN BOX WITH (1) NEW FRP SCREEN BOX
PROJECT TEAM
SITE ADDRESS: 1096 LAGUNA DRIVE
CARLSBAD, CA 92008
PROPERTY OWNER/LESSOR: LAS VILLAS DE CARLSBAD
OPERATIONS, LLC
DAVID THOMPSON, DIRECTOR OF
OPERATIONS
(760) 271-8001
ZONING: R-3
JURISDICTION: CITY OF CARLSBAD
LATITUDE: 33' 10' 0.61" N {NAD 83)
LONGITUDE:
APN:
117" 20' 41.39" W (NAO 83)
155-272-19-00
APPLICANT:
PROJECT
MANAGER:
A&E
MANAGER:
RF ENGINEER:
;ii,· ·Mobile·
10509 VISTA SORRENTO PKWY #206
SAN DIEGO, CA 92121
JOEL SOLORIA
J5 INFRASTRUCTURE PARTNERS
jsoloria@j5ip.com
{619) 977-0283
RAMONA DIPLASIU
JS INFRASTRUCTURE PARTNERS
rdip/asiu@j5ip.com
(949) 247-7767 ext 159
PEDRO ABE
T-MOBILE
Pedro.Abe@T-MOBILE.com
CURRENT USE: UNMANNED TELECOMMUNICATIONS
FACILITY
CONSTRUCT/ON KIRT BABCOCK
PROPOSED USE:
ACCESSIBILITY
REQUIREMENTS:
MANAGER: T-MOBILE
NO CHANGE
THE FACILITY IS UNMANNED AND NOT ZONING
FOR CONTINUOUS HUMAN HABITATION. MANAGER:
DISABLED/CHALLENGED ACCESS IS
NOT REQUIRED PER CBC 2016, SECTION
11 B-203.4 (LIMITED ACCESS SPACE)
STATEMENTS
Kirt.Babcock@T-MOBILE.com
{858) 334-6139
CHRIS VUONG
J5 INFRASTRUCTURE PARTNERS
Cvuong@j5ip.com
(858) 205-4150
STRUCTURAL: STRUCTURAL ANALYSIS JS NOT WITHIN THE SCOPE OF WORK CONTAINED IN THIS DRAWINGS SET. FOR ANALYSIS OF
EXISTING AND/OR PROPOSED COMPONENTS, REFER TO STRUCTURAL ANALYSIS PROVIDED UNDER SEPARATE COVER.
ANTENNA MOUNT ANALYSIS IS NOT WITHIN THE SCOPE OF WORK CONTAINED IN THIS DRAWING SET. FOR ANALYSIS OF ANTENNA
MOUNT TO SUPPORT EXISTING AND /OR PROPOSED COMPONENTS. REFER TO ANTENNA MOUNT STRUCTURAL ANALYSIS PROVIDED
UNDER SEPARATE COVER.
PROPRIETARY INFORMATION: THE INFORMATION CONTAINED WITHIN THIS SET OF DRAWINGS IS PROPRIETARYT-MOBILE. ANY USE
OR DISCLOSURE OTHER THAN AS IT RELATES TOT-MOBILE IS STRICTLY PROHIBITED.
11Mobile ·
T-MOBILE WEST LLC
THE INFORMATION CONTAINED IN THIS SIT OF
DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO
T-MOBILE ANY USE OR DISCLOSURE OTHER THAN AS
IT RELATES TO T-MOBILE IS STRICTLY PROHIBITED
"'j.5 INFRASTRUClURE
P A R T N E R S
0
A
REV
AZ -CA -CO -ID -NM -NV -TX -UT
2030 MAIN STREET, SUITE 200
IRVINE, CA 92614
SITE NUMBER:
SD06088A
SITE NAME:
LAS FLORES
1096 LAGUNA DRIVE
CARLSBAD, CA 92008
08/28/19 1 DO% CONSTRUCTION
06/21 /1 9 90% CONSTRUCTION
DATE DESCRIPTION
JBE
JBE
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET TITLE
TITLE SHEET
SHEET NUMBER
T1
1. FOR mE PURPOSE OF mlS CONSTRUCTION DRA\MNG, THE FOLLO\MNG DEFINITIONS SHALL APPLY:
n L.
3.
CONTRACTOR -GENERAL CONTRACTOR (CONSTRUCTION) AND ANY l_OWER TIER SUBCONTRACTORS.
ENGINEER -JS INFRASTRUCTURE PARTNERS
OWNER -T-MOBILE \lv1RELESS
CONTRACTOR SHALL VISIT THE CELL SITE PRIOR TO THE SUBMISSION OF BIDS TO FAMILIARIZE \MTH THE EXISTING CONDITIONS AND TO CONFIRM THAT mE WORK CAN
BE ACCOMPLISHED faS SHOWN ON THE CONSTRUCTION DR/\WINGS. ANY DISCREPANCY, CONFLICT, OR OMISSION FOUNO SI-VILL BE BROUGHT TO THE ATTENTION OF
THE ENGINEER FOR RESOLUTON, PRIOR TO BID SUBMISSION & PRIOR TO COMMENCEMENT OF ANY WORK. THE CO'{TR/\CTOR SHALL BE RESPONSI BLIE FOR
CORRECTION OF ANY ERRORS, OMISSIONS, OR DISCREPANCIES DISCOVERED AFTER THE COMMENCEMENT OF CONSTRUC1lON WHICH HAVE NOT BEEN BROUGHT TO mE
ATTENTION OF THE ENGINEER. ANY COSTS INCURRED TO REMEDY THE SITUAllON SHALL BE AT THE EXPENSE OF THE CONTRACTOR. THE ENGINEER SHALL APPROVE
ALL METHODS USED TO CORRECTION THE SITUATION.
ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL
ISSUE ALL APPROPRIATE NOTICES AND COMPLY Wlm ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING
THE PERFORMANCE OF THE WORK.
ALL WORK C4RRIED OUT SHALL COMPLY WTH /ILL A0 PLJCABLIE MUNICIPAL AND UTILITY COMPANY SPECIFlCA1lONS AND LOC4L JURISDICllONAL CODES, ORDINANCES AND
APPLICABLE REGULATIONS.
4. THE CONTR/\CTOR SHALL INST/ILL ALL EQUIPMENT AI\JD MAit.RiALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDAllONS UNLIESS SPECIFlCALLY STAllED OTHER'MSE.
5. THE CONTRACTOR SHALL DETERMINE ACTUAL ROUllNG OF CONDUITS AND OTHER CABLES. CONTRACTOR SI-VILL UTILIZE EXISTING TRAYS AND/OR SHALL ADD NEVI/ TRAYS
AS NECESSARY.
6. THE CONTRACTOR Sf-lALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSC4FING AND STRUCTURES ANY DAMAGES SI-VILL BE REPAIRED AT CONTR/\CTOR'S
EXPENSE TO TrlE SATISFACTION OF OWNER.
7. CONTRACTOR SI-VILL LIEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH faS COAXIAL CAB FS AND OTHER TEMS REMOVED FROM THE EXISllNG FACILITY
ANllENNAS REMOVED Sf-iALL BE RETURNED TO THE OWNER'S DESIGNI\TED LOC4TION.
8. AT ANY TIME DURING 1}JE DUR/\TION OF CONSTRUCTION, THE CONTRACTOR SI-VILL BE RESPONSIBLE FOR THE SECURITY OF THE SlllE. CONTR/\CTOR Sf-CM LIEAVE
PREMISES IN CLEAN CONDITION.
9. AS MAY BE REQUIRED BY THE GOVERNING AGENCY OR PROPERTY OWNER, THE CONTR/\CTOR SHALL PROVIDE TEMPORARY POWER, WATER, OR TOILIET FACILITIES.
10. mE EXISTING CELL SITE IS faSSUMED TO BE IN FULL COMMERCIAL OPERATION. ANY CONSTRUCTION WORK BY SUBCONTR/\CTOR SI-VILL NOT DISRUPT llHE EXISTING
NORMAL OPERATION. ANY WORK ON EXISTING EQUIPMENT ~1UST BE COORDINATED WITH THE OWNER. ALSO, WORK MAY NEED TO BE SCHEDULED FOR AN APPROPRIATE
MAINTENANCE WINDOW USUALLY IN LOW TR/\FFIC PERIODS AFTER MIDNIGf-ff.
11. mE CONTR/\CTOR SHALL COMPLY WITH ALL OSHA REGULATIONS DURING THE ENTIRE CONSllRUCTION PERIOD. SINCE THE CELL SITE MAY BE ACTIVE, ALL SAFETY
PRECAUTIONS MUST BE TAKEN VvHEN WORKING AROUND HIGH LEVELS OF ELICTROMAGNEllC R/\DIATION. EQUIPMENT SHOULD BE SHUTDOWN PRIOR TO PERFORMING
ANY WORK THAT COULID EXPOSE THE WCRKERS TO DANGER. PERSONAL RF EXPOSURE MONITORS ARE REQUIRED TO BE WORN TO ALERT OF ANY DANGEROUS
EXPOSURE LEVELS.
12. mE CONTR/\CTOR Sf-iALL NOT USE OR INSTALL A~ff MATERIAL CONTl'-JNING ASBESTOS OR LEAD PAINT CCNTENT THE USE OF SUCH MATERIAL IS STRICTLY PROHIBITED.
13. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES, WHETHER OR NOT SHOWN ON PLANS, AND TO AVOID OR PROTECT THEM FROM
ANY DAMAGE. ANY COSTS INCURRED TO REPAIR UTILITIES DAMAGED DURING CONSllRUCTION SHALL BE AT TrlE SOLIE COST OF THE CONTRACTOR. TELEPHONE 811
FOR USA DIG ALERT.
14. THE GOVERNING AGENCY MAY REQUIRE A COPY OF THE APPROVED PLANS TO BE KEPT ON SlllE AT ALL TIMES. mE CONTR/\CTOR SHALL MAKE SUCH A SET
AVAILABLIE FOR INSPECTION AT ALL TIMES. ANY OEVIAllONS FROM THE APPROVED SET SHALL BE DOCUMENTED AND PROVIDED TO mE ENGINEER FOR APPROVAL. THE
CONTRACTOR SHALL BE4R mE SOLE COST TO CORRECT ANY INSTALLATION WHICH DEVIATES FROM APPROVED PLANS AND iS NOT ACCEPTED BY mE ENGINEER.
15. mE CONTR/\CTOR IS SOLELY RESPONSIBLE FOR ALL MEANS & METHODS, TECHNIQUES, SEQUENCING, AND PROCEDURES REQUIRED TO PERFORM llHE 'NORK. ANY
ANALYSIS OF THE STRUCTURE UNDER TEMPORARY CONSTRUCTION LOADING CONDlllONS iS OUTSIDE OF THE SCOPE OF THESE DR/\\1\INGS. THE CONTRACTOR SHOULID
EVENLY DISTRIBUTE ANY MATERIAL TO BE STORED ON SlllE DURING CONSTRUC1lON SO THAT THE LOAD DOES NOT EXCEED THE STRUCTURES DESIGNED LIVE LOAD; OR
PROVIDE TEMPORARY SHORING OR BRACING IN THESE MEAS.
16. DR/\WINGS ARE NOT TO BE SC4LED. Dl~ENSIONS SHOWN T/IKE PRECEDENCE OVER SCALE.
17. ALL NEW COMPONENTS ADD TO llHE EXTERIOR OF THE STRUCTURE, WHICH ARE VISIBLE FROM PUBLIC VIEW, SHALL BE PAINTED TO MATCH llHE EXISTING CONDITIONS.
18. ALL DETl'-JLS AND NOTES INDICAllED IN THESE PLANS ARE mE MINIMUM REQUIREMENTS.
19. IT MAY BE NECESSARY TO TEMPORARILY RELOC4llE, REMOVE, REPLACE, OR WORK AROUND VARIOUS ARCHITECTURAL FEATURES, PIPES, FlXTURES, CABLING, OR OTHER
NON-STRUCTUR/\L ITEMS IN ORDER TO COMPLIETE THE PROPOSED WORK. CONTR/\CTOR SHALL RESTORE mESE lllEMS TO mEI R ORIGINAL CONDllON
AT llHEIR EXPENSE UNLESS OTHERWISE NOllED IN THESE PLANS.
GENERAL NOTES
SYMBOLS
I S/G I SOLID GROUND BUS BAR
~ SOLID NEUTRAL BUS BAR
~~==="'µ~SUPPLEMENTAL GROUND CONDUCTOR
e 6l'o :,.i..::
0 0
_,-...
0 0
■
•
2-POLE THERMAL-MAGNETIC
CIRCUIT BREAKER
SINGLE-POLE THERMAL-MAGNETIC
CIRCUIT BREAKER
GROUND ROD
DISCONNECT SWITCH
UTILITY METER
EXOTHERMIC CONNECTION (CADWELD) TO
GROUND RING AND COMPRESSION TO
GROUND HALO
COMPRESSION, CLAMP, OR DOUBLE HOLE
LUG TYPE GROUND CONNECTION
LEGEND
GROUND ROD WITH ACCESS
(TEST WELL)
--G--
--T--
--c--
--A--
GROUNDING WIRE, DASHED
REPRESENTS UNDERGROUND
TELEPHONE LINE, DASHED
REPRESENTS UNDERGROUND
COAXIAL CABLE, DASHED
REPRESENTS UNDERGROUND
ANTENNA COAX
-OH/E -OVERHEAD ELECTRICAL CABLES
AGL
(E)
MIN
N.T.S.
REF
RF
TB.D.
TYP
EGR
AWG
lvlGB
EG
BCW
GEN
IGR
ABBREVIATIONS
ABOVE GRADE LEVEL
EXISTING
MINIMUM
NOT TO SCALE
REFERENCE
RADIO FREQUENCY
TO BE DETERMINED
TYPICAL
EQUIPMENT GROUND RING
AMERICAN WIRE GAUGE
MASTER GROUND BUS
EQUIPMENT GROUND
BARE COPPER WIRE
GENERATOR
INTERIOR GROUND RING (HALO)
(P)
EMT
GND
GPS
GFCI
BTCW
PROPOSED
ELECTRICAL METALLIC TUBING
GROUND
GLOBAL POSITIONING SYSTEM
GROUND FAULT CIRCUIT INTERRUPTER
BARE TINNED COPPER WIRE
1. ALL GROUNDING WORK SHALL COMPLY WITH THE LATEST EDITION OF THE CALIFORNIA ELECTRICAL CODE, AS WELL AS WITH ALL LOCAL, STATE, AND NATIONAL CODES, LAWS, AND
ORDINANCES APPLICABLE TO GROUNDING WORK.
2. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE.
3. THE CONTRACTOR IS RESPONSIBLE FOR DROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION SO AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING
SYSTEM OR DAMAGE TO THE CONDUIT.
4. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL GROUNDING INSTALLATION SHALL BE ACCORDING TO SPECIFIC SITE CONDITIONS.
5. GROUNDING CONDUCTORS SHALL BE #2 AWG SOLID BARE TINNED COPPER WIRE, UNLESS NOTED OTHERWISE.
6. APPROVED ANTIOXIDANT COATINGS (I.E., CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS.
7. INSTALL GROUND CONDUCTORS AND GROUND ROD A MINIMUM OF 1 '-0" FROM CONCRETE SLAB, FOOTING, OR FENCE.
8. ALL GROUNDING INSTALLATIONS AND CONNECTIONS SHALL BE MADE BY AN ELECTRICAL CONTRACTOR.
9. MISCELLANEOUS ELECTRICAL AND NON-ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC.
10. METAL CONDUIT AND TRAY SHALL BE GROUNDED ANO MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH 6 AWG COPPER
WIRE AND UL APPROVED GROUNDING TYPE CONDUIT CLAMPS.
11. GROUND CONDUCTORS USED IN THE FACILITY GROUND AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE
CONDUCTOR, SUCH AS METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL
CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC PLASTIC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (E.G., NON-METALLIC CONDUIT PROHIBITED BY
LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT
12. CHEMICAL GROUND SHALL BE XIT, CHEM-ROC, OR APPROVED EQUAL, WHEN REQUIRED.
13. CONNECTIONS TO THE GROUND BARS SHALL NOT BE DOUBLED UP OR STACKED. BACK-TO-BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BAR ARE PERMITTED.
14. NOTIFY PROJECT lvlANAGER !F THERE ARE DIFFICULTIES INSTALLING GROUNDING SYSTEM DUE TO SOIL CONDITIONS.
15. ANY EQUIPMENT, BOX, SKID TO BE GROUNDED AND DOES NOT HAVE A DESIGNATED GROUND CONNECTION SHALL BE DRILLED AS NECESSARY TO CONNECT A GROUND WIRE. REMOVE PAINT
IN AREA UNDER LUG. APPLY ANTI-OXIDANT COMPOUND AND CONNECT WITH TWO-HOLE, COMPRESSION LUG.
16. ALL NEW GROUNDING SHALL CONFORM WITH 'T-MOBILE' GROUNDING STANDARDS.
GROUNDING NOTES
1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL MEANS AND METHODS TO COMPLETE ALL UPGRADES AS INDICATED IN THIS DOCUMENT.
2. ALL DIMENSIONS, SECTIONS AND DETAILS OF THE EX!STING STRUCTURE ARE INCLUDED FOR INFORMATION PURPOSES ONLY. THE CONTRACTOR SHALL VERIFY ALL RELIEVANT INFORMATION PRIOR TO
CONSTRUCTION OR FABRICATION. NOllFY THE ENGINEER-OF-RECORD IMMEDIATELY OF ANY DISCREPANCIES. ALL NEW WORK SHALL ACCOMMODATE EXISTING CONDITIONS.
3. CONTRACTOR IS RESPONSIBLE FOR ERECTING TEMPORARY BARRICADES AND/OR FENCING TO PROTECT THE SAFETY OF mE PUBLIC DURING CONSTRUCTION. THE CONTRACTOR SHALL REMOVE ALL TEMPORARY
BARRIERS AND REPAIR ALL DAMAGE TO PROPERTY ON THE SITE CAUSED BY THIS CONSTRUCTION. THE COST OF REPftJR IS THE CONTRACTOR'S RESPONSIBILITY.
4. ALL WORK SHALL BE IN ACCORDANCE WITH APPLICABLE LOCAL, STATE, AND FEDERAL REQUIREMENTS.
5. COORDINATE WORK INDIC4TED ON THESE DR/\WINGS WITH THE NEW EQUIPMENT, EXISTING EQUIPlvlENT, WAVEGUIDE ETC.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL ME4SUREMENTS AT THE SITE PRIOR TO ORDERING A\JY MATERIALS OR CONDUCTING ANY WORK.
7. ALL DETAILING, FABRICATION AND ERECTION OF STRUCTUR/\L STEEL SHAUL CONFORM TO AISC SPECIFICATIONS AND CODES, LATEST EDlllON.
8. CONTRACTOR SHALL COLD-GALVANIZE ALL RAW STEEL AS REQUIRED DURING CONSTRUCTION PROCESS.
GENERAL UPGRADE NOTES
T-MOBILE WEST LLC
THE INFORMATION CONTAINED IN THIS SET OF
DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO
T-MOBILE ANY USE OR DISCLOSURE OTHER THAN AS
IT RELATES TO T-MOBILE IS STRICTLY PROHIBITED
15 l~~Tf\U0Vftl=
AZ. -CA -CO -ID -NM -NV -TX -UT
2030 MAIN STREET. SUITE 200
IRVINE, CA 92614
Sf IE NUMBER:
SD06088A
SITE NAME:
LAS FLORES
1096 LAGUNA DRIVE
CARLSBAD, CA 92008
0 DB/28/19 100% CONSTRUCTION
A D6/21/19 90% CONSTRUCTION
REV DATE DESCRIPTION
JBE
JBE
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT
SHEET TITLE
GENERAL
NOTES
SHEET NUMBER
T2
SITE PLAN
~ PROPERTY LINE
I
I
(E) BUILDING --t,
(E) 'T-MOBILE'
ENLARGED SITE PLAN
@
/
(E) BUILDING ----
w :z
_J
>-I---
Q:'. w
CL
0
Q:'.
o_
~ w ~
I
I
F
I
I
A P.N :
155-272-19-00
KNOWLES AVENUE
~(E) PARKING AREA~
(E) PROPERTY LINE
~-
LAGUNA DRIVE
~-(E) BUILDING
(E) BUILDING
_,. _,.
\ \
\ \
\
\
DISCLAIMER
THESE DRAWINGS WERE PRODUCED WITHOUT THE BENEFIT OF
A CURRENT LAND SURVEY ALL PROPERTY LINES, EASEMENTS,
AND SETBACKS SHALL BE VERIFIED PRIOR TO START OF
CONSTRUCTION. J5 DOES NOT GUARANTEE THE ACCURACY OF
SAID PROPERTY LINES, EASEMENTS AND SETBACKS.
24"x36" SCALE: 1" = 40' -0"
11"x17" SCALE: 1" = 80'-o" 40 20 0 40' 1
q~ B ·Mobile·
T-MOBILE WEST LLC
THE INFORMATION CONTAINED IN THIS SET OF
DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO
T-MOBILE ANY USE OR DISCLOSURE OTHER THAN AS
IT RELATES TO T-MOBILE IS STRICTLY PROHIBITED
15 l~~U~llj~
0
A
REV
PZ -CA-CO -ID -NM -NV -TX -UT
2030 MAIN STREET, SUITE 200
IRVINE, CA 92614
SITE NUMBER:
SD06088A
SITENAME:
LAS FLORES
1096 LAGUNA DRIVE
CARLSBAD, CA 92008
OB/28/19 100% CONSTRUCTION
06/21/19 90% CONSTRUCTION
DATE DESCRIPTION
JBE
JBE
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET TITLE
SITE PLAN
SHEET NUMBER
A1
\
\
ENLARGED SITE PLAN
□ □ o-□-□-□__.,
'--++-----
I
I
I
_,--
_,--
~(E) BUiLDING ROOFTOPN
(E) 'T-MOBILE'
ANTENNA AREA
@
(E) 'T-MOBILE'
EQUIPMENT AREA
EB
□
~(E) BUILDING ROOFTOP~
24"x36" SCALE: 1 /16" = 1 '-0" ■ trl I tr■ IL IIJIIJIIIJ
11"x17" SCALE: 1/32" = 1'-0" 16' '2' S' 4' O"
"'
,------------(E) BUILDING
11-------------(E) 'T-MOBILE'
ELECTRICAL PANEL
~----------------(E) 'T-MOBILE' _ PANEL A
\
\
__--(E) 'T-MOBILE' CIENA
-----(E) 'T-MOBILE' GPS ANTENNA
__--(E) 'T-MOBILE' RBS 3106
CABINET W/ (E) (1) DUL TO
BE REMOVED AND REPLACED
~---~___...----(E) 'T-MOBILE'
\
\
DISCONNECT
_,.----(E) 'T-MOBILE' RBS
3106 CABINET
EXISTING EQUIPMENT PLAN
NEW EQUIPMENT PLAN
-------------------
r-----------(E) BUILDING
----(E) 'T-MOBILE' GPS ANTENNA
_,.----(E) 'T-MOBILE' RBS 3106
CABINET W/ (N) (2) BB 6630
\
\
@
~---~ _ __---(E) 'T-MOBILE'
DISCONNECT
\
\
_,,--(E) 'T -MOBILE' RBS
3106 CABINET
24"x36" SCALE: 3/8" = 1'-0" ~
11"x17" SCALE: 3/16" = 1'-0" z' 1' o" 2' 3
T-MOBILE WEST LLC
THE INFORMATION CONTAINED IN THIS SET OF
DRAWINGS IS PROPRIETARY & CONFIDENTIAL TD
T-MOBILE ANY USE OR DISCLOSURE OTHER THAN AS
ff RELATES TO T-MOBILE IS STRICTLY PROHIBITED
15 l~~~U~TV~
0
A
REV
AZ. -CA -CO -ID -NM -NV -1X -UT
2030 MAIN STREET, SUITE 200
IRVJNE, CA 92614
SITE NUMBER:
SD06088A
SITE NAME:
LAS FLORES
1096 LAGUNA DRIVE
CARLSBAD, CA 92008
08/28/19 100% CONSTRUCTION
06/21/19 90% CONSTRUCTION
DATE DESCRIPTION
JBE
JBE
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET TITLE
ENLARGED SITE
PLAN & EQUIPMENT
PLANS
SHEET NUMBER
A2
~
0: :::i u w en
a
fD
Cc 0 0 w en
a u a
0: :::i u w en
(E) ANTENNA SCHEDULE
I AZIMUTH RAD CENTER ANTENNA MAKE POS , TECHNOLOGY I I
Al U 1900, G1900, o· 37'-9" ERICSSON U21DO
A2 L2100 o· 37' -9" ERICSSON
A3 ----
A4 ----
81 U 1900, G1900, 125' 37'-9" ERICSSON U2100
B2 L2100 125' 37'-9" ERICSSON
B3 ----
84 ----
C1 U 1900, G1900, 245° 37'-9" ERICSSON U21DO
CZ L2100 245° 37'-9" ERICSSON
C3 ----
C4 ----
(E) 'T-MOBILE' FRP SCREEN \
WALL, TYP. 1 PER SECTOR
A & B (TOTAi -2) L
2'-0" ~ "'
,.
'
(E) 'T-MOBILE' • •
FRP SCREEN BOX
.I
tr=
1 i-.-t-~ I
I I
I
0 I I
co
I
I\ I
\ I
I
-
\ I
I \/ X
0 ~ c--=
OJ 1,.-r
z w I w 0-::
(_) "' (f) I ~
I") o_ ~ I 0-::
I LL
-tj-~ N w
I __J
OJ 0
I 2 I f-
I ~ [] w
j ~
I CJ~ ~" I ,:{1~
I □ I
I
I
I
-I~
~
ANTENNA MODEL RRU MODEL #'S
AIR 21 82A/84P -
AIR 32 B4A/B2P -
--
--
AIR 21 B2A/84P -
AIR 32 B4A/B2P -
--
--
AIR 21 B2A/B4P -
AIR 32 84A/82P -
--
--
10'-o"
(E) 'T-MOBILE' FRP SCREEN WALL '
f 3'-7" f
I I
~ r~
0 1; \ii, c; ..
I
-~---~
(E) HVAC UNIT
TO BE REMOVED,
TYP. (TOTAL-2) ~
I
(E) ROOF
ACCESS HATCH
(E) 'T-MOBILE' PANEL
ANTENNA TO REMAIN, TYP. 1
PER SECTOR C (TOTAL-1)
(E) HVAC ~ UNIT, TYP.
' L □ I
i
~
" -
-
(E) CABLE 1YPE
,
(2) 7 /8" COAX
I
V, u I
(2) 7 /8" COAX w X
"'
n -
(2) 7 /8" COAX
~
__J
__J
<(
:SC
z w w
0-::
(_)
(f)
0 o_ -0-:: I ~ LL
OJ w _j 0 -
I OJ
0
c--i 2 I .. f-
~ ~ w ~
-,~
I
~(E) BUILD!
(E) 'T-MOBILE' PANEL ANTENNA
TO BE RELOCATED, TYP. 2 PER
SECTORS A & BAND 1 PER
SECTOR C (TOTAL-5)
NG ROOFTOP~
\ (E) BUILDING
~ , , (E) T-MOBILE FRP SCREEN BOX
TO BE REMOVED AND REPLACED
EXISTING ANTENNA PLAN
PARPAET
24"x36" SCALE: 3/8" = 1 '-0"
11"x17" SCALE: 3/16" = 1'-0" 2· 1' O" 1
:~
Cc 0 ,-u w U1
a ,rn
Cc
0 ,-u w en
:<->
QC
~ u w en
POS TECHNOLOGY AZIMUTH RAD CENTER
Al U1900, G1900, O' 37'-9"' U2100
AZ L2100 o· 37'-9"
Bl U1900, G1900, 125° 37'-9" U2100
82 LZIOO 125' 37'-9"
C1 U 1900, G1900, 245 37'-9"' U2100
C2 L21D0 245' 37'-9"'
(N) 'T-MOBILE' 6' PANEL ANTENNA --,
TO BE MOUNTED ON (N) PiPE /
MAST, TYP. 1 PER SECTOR C 1
(TOTAL-1
1
(N) ANTENNA SCHEDULE
ANTENNA MAKE ANTENNA MODEL
ERICSSON AIR 21 B2A/B4P
ERICSSON AIR 32 84A/82P
ERICSSON AIR 21 82A/84P
ERICSSON AIR 32 B4A/B2P
ERICSSON AIR 21 B2A/B4P
ERICSSON AIR 32 B4A/B2P
(E) 'T-MOBILE' FRP SCREEN
WALL, 1YP. 1 PER SECTOR
A &: B TOTAL-2
1 o'-o"
RRU MODEL #'S
(E) 'T-MOBILE' FRP SCREEN WALL
(E) CABLE TYPE
: (2) 7 /8"' COAX <,'jC_.,,,
U1 u
I
(2) 7 /8"' COAX >D
X
"'
C,
(2) 7 /8" COAX
(N) CABLE
~-(N) 'T-MOBILE' 4' PANEL ANTENNA
TO BE MOUNTED ON (N) PIPE
MAST, TYP. 1 PER SECTOR A &B
(TOTAL-2
2
(N) 'T-MOBILE'
FRP SCREEN BOX / f f f ----(E) 'T-MOBILE' RELOCATED PANEL
""iili~liEilh/'-1,--=._-=._-=._-=._-=._-=._-=._-=._-=._-=._1.:-=-~~-=--=--=--=--=--=--=--=-~~-=--=--=--=-~==~~;=."::,':_,~~1L-----7'~-"""'-ANTENNA, TYP. 2 PER SECTORS A &
3'-6" 3'-0"
X 0
OJ
z w w Q:'.
(_)
(f)
n o_ ltz
-tj-
N w
_J
OJ 0
2
I ,t-
0
I
-tj-
0
I
~
!!:. ,,,.,,,,, " ,, B AND 1 PER SECTOR C (TOTAL-5)
l~t-------1-1---(N) 'T-MOBILE' RRUS4449
0
\ I
\ I
[J
C
□
l (NJ 'T-MOGILE'
24' -3"x2'-6"x1 o' -1 o"
HIGH FRP SCREEN BOX
TO BE MOUNTED BEHIND
(N) UNISTRUT, TYP. 1
PER SECTOR (TOTAL-3)
~
~-(E) ROOF
ACCESS HATCH
"------(E) 'T-MOBILE' PANEL
ANTENNA TO REMAIN, TYP. 1
PER SECTOR C (TOTAL-1)
(E) HVAC -~
UNIT, TYP.
DC
lO
I
0J
lO
I
0J
(E) BUILDING
PARPAET
0
I
m
_J
_J <r: 5
z w w
Q:'. u
(f)
0...
Q:'.
LL
w
_J
[]J
0
2
I
f-
~ w ~
_ iN) SECTOR B
@ 125° AZIMUTH-
"------(N) 'T-MOBILE' RRUS4449 TO BE
MOUNTED BEHIND (N) PANEL ANTENNA,
TYP. 1 PER SECTOR (TOTAL-3)
(3'{4\
~
~(E) BUILDING ROOFTOP~
NEW ANTENNA PLAN 24"x36" SCALE: 3/8" = 1 '-0"
11"x17" SCALE: 3/16" = 1'-0" 2' 1' o"' 2
!Ill 11111
rl~1
1111 ·Mobile 11
T-MOBILE WEST LLC
THE INFORMATION CONTAINED IN THIS SIT OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO T-MDBILE ANY USE OR DISCLOSURE OTHER THAN AS
fT RELATES TO T-MOBiLE IS STRICTLY PROHIBITED
1s INFRASlRUCTURE p A R T N E R s
0
A
REV
AZ. -CA -CO -ID -NM -NV -TX -UT
2030 MAIN STREET, SUITE 200
IRVINE, CA 92614
SITE NUMBER:
SD06088A
SITE NAME:
LASFLORES
1096 LAGUNA DRIVE
CARLSBAD, CA 92008
08/28/19 100% CONSTRUCTION
06/21/19 90% CONSTRUCTION
DATE DESCRIPTION
JBE
JBE
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET TITLE
ANTENNA PLANS
SHEET NUMBER
A3
I
ill
I ill
EXISTING NORTHEAST ELEVATION
I
I ill
I -ill
NEW NORTHEAST ELEVATION
/~-(E) BUILDING
I I
~I __ s_E_cT_o_R_'_'A_"_~I ~TOR ''c"
0...
0 0:::
-LL
I~
sJ-w
~
.. I I I I I I
'
~--(E) 'T-MOBILE' PANEL ANTENNA TO BE
RELOCATED, TYP. 2 PER SECTORS A & B
AND 1 PER SECTOR C (TOTAL-5)
• •
I ' '
II '
(E) 'T-MOBILE' FRP
SCREEN WALL
(E) 'T -MOBILE' FRP SCREEN BOX
TO BE REMOVED AND REPLACED
•
1-----, -----'-'~1---------'-------------------------+--l 7j1 I I I
y====~=====r================================~~=l-i~-LJ I I I I I I --------------------
,_
,_
,_ l a ~
I
I
a
I l,,j
I
I
EE
LJ ==-=-~ ~.,,,...,,.....,,.,,,,..,,...,,..,..,..,..._f17"Wsni"S'Fa:1""""'""'"'v,w'"""'"""i:1"<11'S:R:FWs::>"D""l:F<!JRi''SJF<Rli"''IJR>...,,.,[R]1'"""'F!F"'"""""",.,,..,..,"""'o,1r -~~~~ r' t
~
i '
l ~ i I
I I I i1 I
i I .r; n ,_ -'
----~
--9 I
' I '
,_
-
,_
I
----ill
ill
' i
(E) 'T -MOBILE' -~
EQUIPMENT AREA
,_ ,_ -,_ I ,_
I
i
ri
I
I I
I I I
_J 11
LJ
0 Q_ ~
---7 -0:::
I Li_
I "
I 0 ~ -w
l -H ~·
I ' n
111'1--
n a rr n l'r--
H
I I
I
0 ill -
I I
I I
ill -
~I __ s_E_cT_' o_R_"A_" -~I ~I __ s_Ec_T_o_R_'_'c_" -~I
I (E) BUILDING
I I
I I
I
I.
I
EE -~-~I ~0 I
I ' ill L I
I ill
I
I I
I
(N) 'T-MOBILE' 4' PANEL ANTENNA ~
TO BE MOUNTED ON (N) PIPE 1
MAST, TYP. 1 PER SECTOR A &B
(TOTAL-2)
0...
0 n:: -LL
I ~ ~ w
~
• ,.
..
ill I I
I !1 ill -
I I
~~
~ ~ ~
(E) 'T -MOBILE' -~
EQUIPMENT AREA
I
~
~-(E) 'T-MOBILE' RELOCATED PANEL
ANTENNA, TYP. 2 PER SECTORS A &
8 AND 1 PER SECTOR C (TOTAL-5)
~ (E) 'T -MOBILE' FRP
SCREEN WALL
2' -c---n •
83
0
I
(N) 'T -MOBILE' 5' PANEL ANTENNA TO
BE MOUNTED ON (N) PIPE MAST, TYP.
1 PER SECTOR C (TOTAL-1)
ill
ill
ill
, I
I ' , I
I
I
-
T.O. (E) FRP SCREEN WALL / (E) 'T-MOBILE' PANEL ANTENNAS 6\
ELEV. 40' -0" (A.G.L.) '-I"
---------_ (E) 'T-MOEll,LE' PANEL ANTENNAS ,RA~,CENTE~ ~
ELEV. 37 -9 (A.G.L.; ,
FINISHED GRADE$
ELEV. o'-o"
24"xJ6" SCALF: 1/8" 1' 0" r--■■-■-■
11"x17" SCALE: 1/16" = 1'-0" 8' 6' 4' 2' o" ' 1 8'
T.O. (E) FRP SCREEN WALL / (N) 'T-MOBILE' PAN~L ~,NTENNAS $
ELEV. 40 -0 (AG.L.)
'T-MOBILE' PANEL ANTENNAS ,RA~;-CENTER $
ELEV. 37 -9 (AG.L.)
~
-~MOBILE' PANEL_ANJENNAS ,RA~, CENTER$
c.LEV. 36 -9 (AG.L.)
FINISHED GRADE$
ELEV. 0'-0"
24"x36" SCALE: 1 /8" 1' o" I"' ■71111 ■ ■ ~--77"x,7" SCALE: 1/76" = 1'-0" 8' 6' 4' 2' o" I 2 8'
T-MOBILE WEST LLC
THE INFORMATION CONTAINED IN THIS SET OF
DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO
T-MOBILE ANY USE OR DISCLOSURE OTHER THAN AS
IT RELATES TO T-MOBILE IS STRICTLY PROHIBITED
15 l~~UC?llj~
AZ -CA -CO -ID -NM -NV -TX -UT
2030 MAIN STREET, SUITE 200
IRVINE, CA 92614
SITE NUMBER:
SD06088A
SITE NAME:
LAS FLORES
1096 LAGUNA DRIVE
CARLSBAD, CA 92008
0 08/28/19 100% CONSTRUCTION
A 06/21/19 90% CONSTRUCTION
REV DATE DESCRIPTION
JBE
JBE
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET TITLE
NORTHEAST
ELEVATIONS
SHEET NUMBER
A4
I SECTOR "8'' I [ SECTOR "A" I ·Mobile· ri"'I Ill 111!1 llill I
T-MOBILE WEST LLC
(E) 'T-MOBILE' PANEL ANTENNA TO BE I
RELOCATED, TYP. 2 PER SECTORS A & B \ THE INFORMATION CONTAINED IN THIS SET OF
AND 1 PER SECTOR C (TOTAL-5) DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO
T-MOBILE ANY USE OR DISCLOSURE OTHER THAN AS
\ IT RELATES TO T-MOBILE IS STRICTLY PROHIBITED
\
-(E) 'T -MOBILE' FRP
(E) BUILDING SCREEN WALL
\ • T.O. (E) FRP SCREEN WALL / (E) 'T-MOBILE' PANEL ANTENNAS~
I : ' ' ' ' ' I ,.. ELEV. 40' -0" (A.G.L.) '-I' I • • ' .
-----------------15 1t'J~U't11j~
: I I I I I I l -
I
I LJ LJ UI -I
L __________ c..J
----------------
(E) 'T -MOBILE' PANEL ANTENNAS ,RA~~CENTER $ ' ,. -' ,_ ,_ ,_ ,_ ----------------,_ ,_ ELEV. 37 -9 (A G L ) AZ. -CA -CO -ID -NM -NV -TX -UT
I ' ,_ ,_ ,_ ,_ ,_ ,_ ' o_ _,,.,.-n ~ n n--0 0--2030 MAIN STREET, SUITE 200 ...cc.:::rr: n n n r, ' l')TTTT11~ -LL IRVINE, CA 92614 ! I I I -tj-'w / ' / ' r----
------,___,..---I (=_,,------------------c------~ ~ -------[I] [I] --, ~ [I]
I: I I I -r ~ ~ -
!1
--~
1 I
SITE NUMBER:
I rng;1 I I I I i ~ --~
I SD06088A ,. I ~--------I L
I SIIENAME: s'.=~ -~ ill ill ill I I
LAS FLORES -~ --'=== ,~1 I I .
~-II I II FINISHED GRADE$
ELEV. o'-o"
(E) 'T-MOBILE' 1096 LAGUNA DRIVE EQUIPMENT AREA
CARLSBAD, CA 92008
EXISTING SOUTHEAST ELEVATION 24"x36" SCA! E: 1/8" 1' o" l""I ---J 1 ----11"x17" SCALE: 1/16" = 1'-0" 8' 6' 4· 2· o" 8'
I SECTOR "B" I I SECTOR "A" I
(E) 'T-MOBILE' RELOCATED PANEL
ANTENNA, TYP. 2 PER SECTORS A &
B AND 1 PER SECTOR C (TOTAL-5)
(N) 'T-MOBILE' 4' PANEL ANTENNA
TO BE MOUNTED ON (N) PIPE 0 08/28/19 1 DD% CONSTRUCTION JBE
MAST, TYP. 1 PER SECTOR A &B -(E) 'T-MOBILE' FRP A 06/21/19 90% CONSTRUCTION JBE
(TOTAL-2) SCREEN WALL REV DATE DESCRIPTION (E) BUILDING
• T.O. (E) FRP SCREEN WALL / (N) 'T-MOBILE' PANEL ANTFNNAS ~
I I ' I ' ' ' I ~ ELEV. 40' -0" (AG.L) '-f'
' I I I I I l I
= ---...________ ----------------I I !:-_~_!d_ __ L_J_ ~J • ~ ----------------
(E) 'T-MDBILE' PANEL AN~ENNAS _RA~_CENTER $ I ,.. ~ -I ---------------ELEV. 37 -9 (A.G.L) --~ ,_ o_
-[I
~ l'i--0 0--~~MOBILE' PANEL__ANTENNAS ,RA~. CENTER$ ,_ ,_
~"n~n TT n o _11:;o-., -LL I I I I -tj-C ELEV. 37 -0 (A.G.L.)
/ / r----~ ,----~-------------
~ -----.--------,___, -[I] [I]
1! I I I
~
I [I] I I I
--I --' ~ --I I i
I I i i
I i i ;1
' '
~ IT IS A VIOLATION OF LAW FOR ANY PERSON, 11 I
I I I I I I I I I Ir-~ UNLESS THEY ARE ACTING UNDER THE DIRECTION ~ OF A LICENSED PROFESSIONAL ENGINEER, I ill TO ALTER THIS DOCUMENT.
I I '.1 I~
~ SHEET TITLE r-----,__, "---' ~ ill ill ill -~ ---
I
i SOUTHEAST i I ~i1
I '
I ELEVATIONS II II FINISHED GRADE~
ELEV. D' -0" '-f'
(E) 'T-MOBILE'
EQUIPMENT AREA
SHEET NUMBER
AS
NEW SOUTHEAST ELEVATION 24"x36" SCALE: 1/8" 1' o" l""I~-
J 2 ■J ■~ 11"x77" SCALE: 1/-5" -· o" 5' 6' 4' 2· o" 8' I = I -
----------------------~----
~-s_E_c-_,o_R_'_'c_"_~II ~ __ s_Ec_T_o_R_'_'B_" -~
~ T.O. (E) ,FR~, SCREEN WALL / (E) 'T-MOBILE'
, ELEV. 40 -0 (A.GL)
$ (E) 'T-M,OBl~E' PANEL_ANTENNAS RAD CENTER
ELEV. 37 -9 (A.GL)
~ FINISHED GRADE
, ELEV. o' -o"
(E) 'T MOBILE' PANE' -L
ANTENNA TO REMAIN, TYP. 1
PER SECTOR C (TOTAL-I)
(E) 'T-MOBILE' FRP SCREEN BOX
TO BE REMOVED AND REPLACED
PANEL ANTENNAS
--
<'. -1
1 j I
..-4) 1 I I
---r-rni/ill"t
--I ,_
.--L
ill -
-
ill -
11r= "
----------v
ill -
EXISTING SOUTHWEST ELEVATION
... 2·-0"
~ .:1
7 I
I 11
I
'
I
,_ ,_
----
' ill
rn
ill
(E) 'T-MOBILE' PANEL ANTENNA
TO BE RELOCATED, TYP. 2 PER
SECTORS A & BAND 1 PER
SECTOR C (TOTAL-5)
I I
I ! I
' I l -' ' l ,_ -
I I ,_
·-,_ -,_ -
·-1 -' -,_ I '
,,-------~ -----~
I
R --
m I ~ 11 m • -
JD -ml I ' I
--
g] -ill
I
~_s_Ec_T_o_R_'_'c_" -~I l~_s_E_cT_o_R_"B_"_~
(N) 'T MOBILE' 6' PANEL ANTENNA TO -
BE MOUNTED ON (N) PIPE MAST, TYP. (E) 'T-MOBILE' RELOCATED PANEL I PER SECTOR C (TOTA~ -1) ANTENNA, TYP. 2 PER SECTORS A &
BAND 1 PER SECTOR C (TOTAL-5)
(N) 'T-MOBILE' (N) 'T-MOBILE' 4' PANEL ANTENNA 24' -3"x2' -6" FRP TO BE MOUNTED ON (N) PIPE SCREEN BOX MAST, TYP. 1 PER SECTOR A&B 2'-6" (TOTAL-2)
~
$ T.O. (N), FR~ SCREEN BOX / (N) 'T-MOBILE' PANEL ANTENNAS ~ ' I I ELEV. 4D -0 (A.G.L.)
I I I / --
-$ (E) 'T-M,OBl~E' PANEL_ANTENNAS RAD CENTER -C , " I ' 1 ,_ ,_ -j ' I I ELEV. 37 -9 (A.G.L.) / ~ I I
~ ...,-r I I I I I
$ (N) 'T-M,OBi,~E' PANE~ANTENNAS RAD CENTER ----nil Fl ii r1 I \ -1 ,_ -,_' ,_, ,_ -,_ -' I
-~I ' I ---,_
'
,_ --,_ ,_ ,_ -ELEV. 36 -9 (A.G.L.)
~ ~
~ ~ ----ill
~
ill I -_, -I
!'m mm mm JI • 11! ,ii ' I
ill ill ' I I i -
I
~ I
~ mm DUD, ■ ·--.mi
ill -ill ill -ill
FINISHED GRADE $ ELEV. 0'-0"
I
NEW SOUTHWEST ELEVATION
(E) BUILDING
I
I
l I
i \ -i ,_ ,_ --n n--
i Ii Ii IT IT fl Ii 11 n Ii JULo I I n n n 11 71--.,.,
/
I
' ill [I] ill -
'iiarn
!
ill [I] ill -
l ) I
ill ill -
(E) BUILDING
I
I I I
I
,_ -·-ncr-,_
1 ff ff i1 i1 n n n JU! fl n i1 \ -fff\f/n~
ill ![I] ill 1'
' 11
ill [I] ill -
"""" ~ J
ill ill -
I
24"x36" SCALE: 1/8" = 1'-o" r-.•-•.r.
11"x17" SCALE: 1/16" = 1'-o" 8' 6' 4' 2' o"
I
24•'x36" SCALE: 1 /8" = 1 '-0" r!'lw,*■•■r•
11"x17" SCALE: 1 /16" = 1 '-0" 8' 6' 4' 2' o" I 2 8'
l"I·."''I 1111 1111 !Iii ,,
' ·Mobile-
T-MOBILE WEST LLC
THE INFORMATION CONTAINED IN THIS SIT OF
DRAWINGS IS PROPRIITARY & CONFIDENTIAL TO
T-MOBILE ANY USE DR DISCLOSURE OTHER THAN AS
IT RELATES TO T-MOBILE IS STRICTLY PROHIBITED
15 IC'J~~U':Tlj~
0
A
REV
AZ. -CA -CO -ID -NM -NV -TX -UT
2030 MAIN STREET. SUITE 200
IRVINE, CA 92614
SITE NUMBER:
SD06088A
SIIENAME:
LASFLORES
1096 LAGUNA DRIVE
CARLSBAD, CA 92008
08/28/19 100% CONSTRUCTION
06/21/19 90% CONSTRUCTION
DATE DESCRIPTION
JBE
JBE
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET TITLE
SOUTHWEST
ELEVATIONS
SHEET NUMBER
A6
T.O. E FRP SCREEN WALL E 'T-MOBILE' PANEL ANTENNAS
ELEV. 40' -0" (A.G.L.)
$ (E) 'T-M,OBl~E' PANEL_ANTENNAS RAD CENTER
ELEV. 37 -9 (A G.L.)
$ FINISHED GRADE
ELEV. 0' -0"
EXISTING NORTHWEST ELEVATION
(N) 'T-MOBILE' 6' PANEL ANTENNA TO --
BE MOUNTED ON (N) P!PE MAST, TYP.
1 PER SECTOR C (TOTAL -1)
(N) 'T-MOBILE' 4' PANEL ANTENNA --
TO BE MOUNTED ON (N) PIPE
MAST, TYP. 1 PER SECTOR A &B
(TOTAL-2)
$ T.O. (N), FR~ SCREEN BOX / (N) 'T-MOBILE' PANEL ANTENNAS
ELEV. 40 -0 (A.G.L.)
$ (E) 'T-M,OBl~E' PANEL_ANTENNAS RAD CENTER
ELEV. 37 -9 (A.G.L.)
_//-_
$ (N) 'T-MOBILE' PANEL ANTENNAS RAD CENTER _ _/
ELEV. 36' -9" (A.G.L.)
FINISHED GRADE
ELEV. O' -0"
NEW NORTHWEST ELEVATION
I
~-s_E_c-_1 o_R_'_'A_" -~II ~ __ s_Ec_T_o_R_·_·c_" -~
[L 111 I 0 O'.'. ULJ LL I -~ 0 w
~ ~
I I
LJ
~---(E) 'T-MDBILE' PANEL ANTENNA
TO BE RELOCATED, TYP. 2 PER
SECTORS A & BAND 1 PER
SECTOR C (TOTAL-5)
(E) 'T-MOB!LE' PANEL
ANTENNA TO REMAIN, TYP. 1
PER SECTOR C (TOTAL -1)
/
,---(E) 'T-MOBILE' FRP SCREEN BOX
TO BE REMOVED AND REPLACED
I
rn
rn
~_s_E_cT_o_R_'_'A_" -~I l~ __ s_Ec_T_o_R_'_'c_" -~
0 [L
~ O'.'.
I LL
~-(E) 'T-MOBILE' RELOCATED PANEL
ANTENNA, TYP. 2 PER SECTORS A &
B AND 1 PER SECTOR C (TOTAL-5)
~-(E) 'T-MOBILE' PANEL
ANTENNA TO REMAIN, TYP. 1
PER SECTOR C (TOTAL -1)
~-(N) 'T-MOBILE'
I I
I
I
24'-3''x2'-6" FRP
SCREEN BOX
rn
' I
rn
~-(E) BUILDING
rn EB ill
EB
iiii
24"x36" SCALE: 1/8" = 7'-o" r-,_•.-.;.
11"x17" SCALE: 1/16" = 1'-0" 8' 5' 4' 2' O" l 1 5'
~-(E) BUILDING
I '
rn
EB
:!ii ii!i
24"x36" SCALE: 1/8" = 1'-0" r-.-.-.r.
11"x17" SCALE: 7/16" = 1'-0" 8' 6' 4' z' o" l 2 8'
F]"'"I
11111111!1 Ill ·Mobile·
T-MOBILE WEST LLC
THE INFORMATION CONTAINED IN THIS SIT OF
DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO
T-MOBILE ANY USE OR DISCLOSURE OTHER THAN AS
T RELATES TOT-MOBILE IS STRICTLY PROHIBITED
45 INFRASTRUCTIJRE JI P A R T N E R S
0
A
REV
AZ. -CA -CO -ID -NM -NV -TX -UT
2030 MAIN STREET, SUITE 200
IRVINE, CA 92614
SITE NUMBER:
SD06088A
Sil'ENAME:
LAS FLORES
1096 LAGUNA DRIVE
CARLSBAD, CA 92008
08/28/19 100% CONSTRUCTION
06/21/19 90% CONSTRUCTION
DATE DESCRIPTION
JBE
JBE
IT IS A VIOLATION OF LAW FDR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET TITLE
NORTHWEST
ELEVATIONS
SHEET NUMBER
A7
Do_:,u,~~~~ ~~velope ID: 94643D67-18CC-4581-876A-5BBEF3160694 ~.JOe088A _ L600_6.2_2019-08-15
RAN Tc111plD11::: ML Tcmplll.tc: PowcrSys"klmTcffiFI.SII: SD06088A L600 6.2 67D02C Outdoor 67002C_2xAIR+10P Custom
StteJD: SD060B8A
StU4: Final
V<lf'Uall: 6.2
Pro!KtT~: L600
Apprtlolld: 8115/2019 5:20:25 PM
ApprowdB1: GSM1900UChavez27
LutModilled: 8/1512019 5:20:25 PM
lntModiri.dBy: GSM1900\JChavez27
AANTamplata: 67002C Outdoo.-
Sector Coom:: 3 All1too■ Count: 9
Section 1 -Site Information
Sito N.IM: SD08S_Los Villas de Carls
SIN ci .. ,: Side Mo~,t
Sha T)'l)e: Bui!ding
~nYtar: 2019
M•riel: SAN DIEGO
"-1dot': Ericsson
LMdord: Private ll
l.atl\llff: 33.1568375000
l.ollgltudt: -117 .3448300000
Menu: 1088 LAGUNA DR
Ctt,,Stat,: Carlsbad, CA
Rewio,,: \\'EST
/IJ. T-i,lflt: 67D02C_2xAIR+10P
RJIUCo1.1M: 3
Section 2 -Existing Template Images
SD06088A _ 1 __proposed .jpg
Site Configuration 2C AIR B;;ised with RBS31Q6
Notes·
ALPIU.
Sp:oeolo,A,lVlo
c,..,.i,..,.11t><1 ~ l>o ""'-"<I I~•~••"'"'•' as-
For 3100 ,c,ual
hni,letMn:11.«1 may
e11rro, 1,om ~ u,yc,11 r
..chemollc ~how,,
rfds .eng. I-mobile .comJDa taSheeVPrintoutl 11924028
EX ISTIN G RFDS PLUMBING DIAGRAM
UTA GAMMA ....... ,, .,.,
~ ,~ j= Numbtr •Pd typt ol
1"'r"f' ~ w HCS c.tll■ wlll 17 -deptnd on l~h
11nd structura
HW or cable$ lt1at
will be add<.KI In
""
For Sltos wfUI
cdstlng RBS
J106
lnltJ.al AIR •nt■nn■ dallwry wih not
t>t tt,vlng RET ln1erconn..::t1Yity
be'--1 it.cUve ■nd pnalv■ sldu
--
1111
Do_:,u,~~i~ ~_!lvelope 1 D: 94643D67-18CC-4581-876A-5BBEF3160694 ,_,.J060S8A_LB00_G.2_2o19-08-is
Section 3 -Proposed Template Images
SO06088A_67D02C_2xAIR+1 OP.jpg
JJ;t c,,,~owPlk!n firnm -emnoos
-
1
Notes:
Mustafa Aj mal 8/16/2019
RF Manager
rfds.eng. t-mobile.comJDataSheet/Pri nto ut/1192 4028 2/11
N EW RFDS PLUMBING DIAGRAM 2
T-MOBILE WEST LLC
THE:: INFORMATION CONTAINED IN TH IS SIT OF
DRAWl ~GS IS PROPRIETA.RY & CONFID ENTIAL TO
T-MDBILE ANY USE OR DIS CLOSURE OTHER THAN AS
rT RELA.~ES TO T-MOBILE IS STRICTLY PROHIBITED
15 l~~U~llj~
0
A
REI/
AZ. -CA -CO -ID -NM -NV -TX -UT
203" MAIN STREET, SUITE 200
IRVINE, CA 92614
SITE NUMBER:
SD06088A
SITE NAME:
LAS FLORES
1096 LAGUNA DRIVE
CARLSBAD, CA 92008
08/28/19 100% CONSTRUCTION
06/21/19 90% CONSTRUCTION
DATE DESCRIPTION
J3E
J3E
IT IS A VIDLATICN OF _AW FDR ANY PERSOol,
UNLESS THEY AR':. ACTING UNDER THE DIRECT ION
OF A _ICENSED PROFESSIONAL ENGINEC:R,
TO ALE., TrlS DOCUMENT.
SH EC:T TITLE
RFDS PLU MBIN G
DIAGRAM
SH EET NUMBER
A8
PIPE TRANSFER KIT PROVIDED
BY MANUFACTURER---~
ANTENNA DOWNTILT MOUNTING KIT----+~ ' '
' ,,
(N) PANEL ANTENNA-----------+---+-------1II
: i EB
(N)/(E) PIPE 2"¢ X 8' -0" STD.~~---i
ANTENNA MOUNTING DETAIL SCALE
N.T.S. 1
--------(N) PIPE 2.5 STD MAST
OR (E) PIPE SUPPORT
RELOCATED
__.,--1 /2" DIA U-BOLT
(N) ANGLE PER PLAN
ANGLE STEEL TO PIPE MAST DETAIL SCALE 5 ---N.T.S.
SXK 125 0246/1.
PROVIDED BY
MANUFACTURER
(P) SCREWS ( 4 PER
MOUNT), PROVIDED BY
MANUFACTURER---
(TOTAL-2 PER RRU) ----~~
P 1007 NUTS WITH
SPRING, AS REQUIRED
PER EQUIPMENT
MANUFACTURE'S
SPECIFICATIONS
P1000 UNISTRUT, OR
APPROVED EQUAL, TYP ---~
RRU MOUNTING DETAIL
NOTE
1. USE MANUFACTURER SUPPLIED
MOUNTING HARDWARE.
REMOTE RADIO
UNIT (RRU)
SCALE
N.T.S. 9
25.2"
1
N
co
sj-
~
FRONT SIDE
ANTENl~A SPECIFICATIONS
MANUFACTURER· COMMSCOPE
MODEL: FFHH-65A-R3
LENGTH: 48.2" IN
WIDTH: 25.2" IN
DEPTH 9.3" IN
PORT COUNT: 8
WEIGHT: 72.8 LBS W/0
MOUNTING BRACKET
11 l I
• •
TOP
FRONT
MOUNTING KIT OPTIONS:
-~,-, /;f (
~~
ic.··.,,,j "
SIDE
RRUS 4449 SPECIFICATIONS
MANUFACTURER: ERICSSON
MODEL: RRUS 4449
HEIGHT 17.9 IN
WIDTH: 13.19 IN
DEPTH: 10.6 IN
WEIGHT 75 LBS
NOTE:
1. USE MANUFACTURER
SUPPLIED MOUNTING
HARDWARE FOR RRUS
ATTACHMENT.
r
i
,•-...._
"),,! ;!,•· '·•w
ANTENNA SPECIFICATIONS 2 RRUS 4449 SPECIFICATIONS SCALE
N.TS. 3
NOTE:
1. USE MANUFACTURER SUPPLIED
lvlOUNTING HARDWARE
BASEBAND 6630 SPECS
N r--
24"
FRONT
f
8.5"
f f
SIDE
EQUIPMENT SPECIFICATIONS
MANUFACTURER ERICSSON
MODEL: BASEBAND 6630
HEIGHT: 1.7 IN
WIDTH: 13.86 IN
DEPTH: 19 IN
WEIGHT: 14.33 LBS
SCALE 6 ---N.T.S.
ANTENNA SPECIFICATIONS
MANUFACTURER: RFS
MODEL APXVAARR 18_ 43-U-NA20
LENGTH: 72 IN
WIDTH: 24 IN
DEPTH: 8.5 IN
PORT COUNT: B
WEIGHT: 1 06 LBS
BOTTOM
~-FITS 1 ½" TO 3 ½" PIPE O.D.
0
6 X 5" ~ •
li 4 %" i I I
~
I@ ~I
PIPE TO PIPE CLAMP SET
ANTENNA SPECIFICATIONS _sc_AL_E-10 NOT USED N.T.S.
CLAMP SPECIFICATIONS:
MANUFACTURER: VALMONT
MODEL: ACP1 OK
WEIGHT: 9.38 LBS
SCALE 7 ---N.T.S
11
(N) RRU MOUNTED ON
ANTENNA STAND-OFF ARM~~~
(N) MANUFACTURER
SUPPLIED HARDWARE,
(J] z: ·o 0::: -LL i-20
0::: LL
Wu D... Li.J
o_
(J]
TYP 2 PER UNISTRUT~~
NOTE~
1. USE MANUFACTURER SUPPLIED
MOUNTING HARDWARE.
PIPE MOUNT-----------,..--Jv
RRU MOUNTING DETAIL
COPPER BRAID----..
COPPER CONDUCTOR
PVC-NYLON INSULATION
PVC SHEATH-------1-
INNER COVERING,
POLYESTER TAPE ___ ___,,.
NON-HYGROSCOPIC DUMMY
CORES AS NEEDED ----------
ERICSSON PART NUMBER UTDC1 B 500M
DIMENSIONS:
• OUTER DIA. NOMINAL:
• OUTER DIA. MIN:
• OUTER DIA. MAX:
• MIN. AVERAGE JACKET WALL THICKNESS
6AWG DC CABLE SPECS
NOT USED
SCA~E ---4 N.T.S.
0.68" (17.3MM)
0. 64" ( 16.2MM)
0. 7 4" ( 18.8MM)
0.085" (2.16MM)
SCALE
NT.S 8
12
T-MOBILE WEST LLC
THE INFORMATION CONTAINED IN THIS SIT OF
DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO
T-MOBILE ANY USE OR DISCLOSURE OTHER THAN AS
rT RELATES TO T-MOBILE IS STRICTLY PROHIBITED
/l.j'"5 INFRASlRUCTURE
P A R T N E R S
AZ -CA -CO -ID -NM -NV -TX -UT
0
A
REV
2030 MAIN STREET. SUITE 200
IRVINE, CA 92614
SITE NUMBER:
SD06088A
SITE NAME:
LAS FLORES
1096 LAGUNA DRIVE
CARLSBAD, CA 92008
08/28/19 100% CONSTRUCTION
06/2'1/19 90% CONSTRUCTION
DATE DESCRIPTION
JBE
JBE
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET TITLE
DETAILS
SHEET NUMBER
D1
GROUNDING NOTES:
1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL GROUNDING INSTALLATION REQUIREMENTS AND CONSTRUCTION ACCORDING TO SITE
CONDITIONS
2. ALL GROUNDING CONDUCTORS: #2 AWG SOLID BARE TINNED COPPER WIRE UNLESS OTHERWISE NOTED.
3. GROUND BAR LOCATED IN BASE OF EQUIPMENT WILL BE PROVIDED, FURNISHED AND INSTALLED BY THE VENDOR.
4. ALL BELOW GRADE CONNECTIONS: EXOTHERMIC WELD TYPE, ABOVE GRADE CONNECTIONS: EXOTHERMIC WELD TYPE.
5. GROUND RING SHALL BE LOCATED A MINIMUM OF 24'• BELOW GRADE OR 6" MINIMUM BELOW THE FROST LINE.
6. INSTALL GROUND CONDUCTORS AND GROUND ROD MltJIMUM OF 1 '-o" FROM EQUIPMENT CONCRETE SLAB, SPREAD FOOTING, OR FENCE.
7. EXOTHERMIC WELD GROUND CONNECTION TO FENCE F10ST: TREAT WITH A COLD GALVANIZED SPRAY.
8. GROUND BARS:
A) EQUIPMENT GROUND BUS BAR (EGB) LOCATED AT THE BOTTOM OF ANTENNA POLE/MAST FOR MAKING GROUNDING JUMPER CONNECTIONS
TO COAX FEEDER CABLE SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. JUMPERS (FURNISHED BY OWNERS) SHALL BE
INSTALLED AND CONNECTED BY ELECTRICAL CONTRACTOR
9. ALL GROUNDING INSTALLATIONS AND CONNECTIONS SHALL BE MADE BY ELECTRICAL CONTRACTOR
10 OBSERVE N.E.C. AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE GROUNDING.
11. GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS OR AT GROUNDING POINTS PROVIDED (2 MINIMUM).
12. IF EQUIPMENT IS IN A CL FENCE ENCLOSURE, GROUND ONLY CORNER POSTS AND SUPPORT POSTS OF GATE. IF CHAIN LINK LID IS USED,
THEN GROUND LID ALSO.
13. GROUNDING AT PPC CABINET SHALL BE VERTICALLY INSTALLED.
14. ALL GROUNDING FOR ANTENNAS SHALL BE CONNECTED SO THAT IT WILL BY-PASS MAIN BUSS BAR.
15. ALL EMT RUNS SHALL BE GROUNDED AND HAVE A BUSHING, NO PVC ABOVE GROUND.
16. USE SEPARATE HOLES FOR GROUNDING AT BUSS BAR. NO "DOUBLE-UP" OF LUGS.
17. POWER AND TELCO CABINETS SHALL BE GROUNDED (BONDED) TOGETHER.
18. NO LB'S ALLOWED ON GROUNDING.
19. PROVIDE STAINLESS STEEL CLAMP AND BRASS TAGS ON COAX AT ANTENNAS AND DOGHOUSE.
20 ALL ELECTRICAL AND GROUNDING AT THE CELL SITE SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (NEC), NATIONAL FIRE PROTECTION
ASSOCIATION (NFPA) 780 (LATEST EDITION), AND MANUFACTURER SPECIFICATION.
21 IF THE AC PANEL IN THE POWER CABINET IS WIRED AS SERVICE ENTRANCE, THE AC SERVICE GROUND CONDUCTOR SHALL BE CONNECTED TO
GROUND ELECTRODE SYSTEM. WHEN THE AC PANEL IN THE POWER CABINET IS CONSIDERED A SUB-PANEL, THE GROUND WIRE SHALL
BE INSTALLED IN THE AC POWER CONDUIT. THE INSTALLATION SHALL BE PER LOCAL AND NATIONAL ELECTRIC CODE (NFPA-70).
22 EXOTHERMIC WELDING IS RECOMMENDED FOR GROUNDING CONNECTION WHERE PRACTICAL. OTHERWISE, THE CONNECTION SHALL BE MADE US!NG
COMPRESSION TYPE-2 HOLES. LONG BARREL LUGS OR DOUBLE CRIMP CLAMP "c" CLAMP. THE COPPER CABLES SHALL BE COATED WITH
ANTIOXIDANT (COPPER SHIELD) BEFORE MAKING THE CONNECTIONS. THE MANUFACTURER'S TORQUING RECOMMENDATIONS ON THE BOLT ASSEMBLY
TO SECURE CONNECTIONS SHALL BE FOLLOWED.
23 THE ANTENNA CABLES SHALL BE GROUNDED AT THE TOP AND BOTTOM OF THE VERTICAL RUN FOR LIGHTING PROTECTION. THE ANTENNA CABLE
SHIELD SHALL BE BONDED TO A COPPER GROUND BUSS AT THE LOWER MOST POINT OF A VERTICAL RUN JUST BEFORE IT BEGINS TO BEND
TOWARD THE HORIZONTAL PLANE. WIRE RUNS TO GROUND SHALL BE KEPT AS STRAIGHT AND SHORT AS POSSIBLE. ANTENNA CABLE SHIELD
SHALL BE GROUNDED JUST BEFORE ENTERING THE CELL CABINET. ANY ANTENNA CABLES OVER 200 FEET IN LENGTH SHALL ALSO BE EQUIPPED
WITH ADDITIONAL GROUNDING AT MID-POINT.
24 ALL GROUNDING CONDUCTORS INSIDE THE BUILDING SHALL BE RUN IN CONDUIT RACEWAY SYSTEM, AND SHALL BE INSTALLED AS STRAIGHT AS
PRACTICAL WITH MINOR BENDS TO AVOID OBSTRUCTIONS. THE BENDING RADIUS OF ANY #2 GROUNDING CONDUCTOR IS B" PVC RACEWAY MAY
BE FLEXIBLE OR RIGID PER THE FIELD CONDITIONS. GROUNDING CONDUCTORS SHALL NOT MAKE CONTACT WITH ANY METALL:C CONDUITS,
SURFACES OR EQUIPMENT
25 PROVIDE PVC SLEEVES WHERE GROUNDING CONDUCTORS PASS THROUGH THE BUILDING WALLS AND /DR CE!LINGS.
26. INSTALL GROUND BUSHINGS ON ALL METALLIC CONDUITS AND BOND TO THE EQUIPMENT GROUND BUSS IN THE PANEL BOARD.
27 GROUND ANTENNA BASES, FRAMES, CABLE RACKS AND OTHER METALLIC COMPONENTS WITH #2 GROUND!NG CONDUCTORS AND CONNECT TO
INSULATED SURFACE MOUNTED GROUND BARS. CONNECTION DETAILS SHALL FOLLOW MANUFACTURER'S SPEC!FICATIONS FOR GROUNDING.
28. ALL PROPOSED GROUNDING CONDUCTORS SHALL BE ROUTED AND CONNECTED TO THE MAIN GROUND BAR OR EXISTING GROUND RING.
NOTES
CO,'IX CABLES
!
ANTENNA
GROUND KiT I
I
1 ,.
SCALE
N.T.S.
NOTES:
1. GROUND BAR LOCATION IS SCHEMATIC AS
SHOWN ON THIS SHEET AND ACTUAL
LOCATION OF INSTALLATION WILL BE
DETERMINED BY THE INSTALLER.
2. REFER TO ANTENNA PLAN FOR EXACT
NUMBER OF ANTENNA, RRU AND DC SURGE
SUPPRESSOR
-----+---------+--, ________,,, // r /
c>-----JUMPER
-
AWG 6 (TYP)
AWG 2 (TYP)
SECTOR ANTENNA
GROUND BAR
AWG 2 BCW TO GROUND RING
I I I
lt lt ••
RRU RRU DC-SURGE
~-;--=-~:::f7----n . • .,,~/ '" -r
~T/ AWG 2
"------AWG 2
IL__ _ _,,.___. __ J:-~-ANTENNA GROUND BAR @
TOP & BOTTOM OF POLE
I I
J T'---~AWG 2 BCW TO GROUND RING
TYP. ANTENNA GROUNDING DIAGRAM
1
3
NOT USED
KEY NOTES:
0 (E) ANTENNA GROUND BAR
TO BE VERIFIED @ FIELD W (N) AWG 2 INSULATED COPPER GROUND WIRE
FROM (N) RRUS TO (E) ANTENNA GROU1\JD BAR
~ (N) AWG 6 INSULATED COPPER GROUND WiRE
FROM GROUND KIT TO (E) ANTENNA GROUND BAR
NOTES:
1. REFER TO TYP. ANTENNA GROUNDING DIAGRAM
2. (E) GROUND WIRES ARE NOT SHOWN FOR CLARITY
I\ i
\ I
\ I
\/
LJ
□
[J
I
ANTENNA GROUNDING PLAN, TYP. PER SECTOR
3
1
I
2
~(E) BUILDING ROOFTOPN
D LJ LJ
24"x36" SCALE: 3/8" -1 '-0" ~ ~
11··x17" SCALE: 3/16" -1'-0" 2' 1' o" 2' ~ 4
T-MOBILE WEST LLC
THE INFORMATION CONTAINED IN THIS SIT OF
DRAWINGS IS PROPRIITARY & CONFIDENTIAL TO
T-MOBILE ANY USE OR DISCLOSURE OTHER THi'.N AS
IT RELATES TO T-MOBILE IS STRICTLY PROHIBITED
ti,·5 INFRASTRUCTURE
P A R T N E R S
AZ. -CA -CO -ID -NM -NV -TX -UT
2030 MAIN STREET, SUITE 200
IRVINE. CA 92614
SITE NLlMBER:
SD06088A
SITENAME:
LAS FLORES
1096 LAGUNA DRIVE
CARLSBAD, CA 92008
0 08/28/19 100% CONSTRUCTION
A 06/21/19 90% CONSTRUCTION
REV DATE DESCRIPTION
JBE
JBE
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET TITLE
GROUNDING PLAN
& NOTES
SHEET NUMBER
G1
NOT USED
NOT USED
TfPE ND
0
v
UNIVERSAL PIPE
CLAMP 75/1 25
UNIVERSAL PIPE
CLAMP 50H2
TYPE NX1 TfPE RR
TYPE SS TYPE TA
TfPE XA TYPE GT
TYPE I J TYPE HA
TYPICAL MECHANICAL CONNECTIONS
1 NOT USED
NEW GPS ANTENNA~-~
CABLE TO PIPE
CONNECT BURNDY TYPE
~
GAR, TYP. (2) PLACESc--------,
j_l
#2 AWG BCW, TYP.
(2) PLACES
MOUNTING BRACKET
1 /2''r/J COAX CABLE
GROUNDING KIT
I,
\
(• "JrjL JJ #6 AWG GROUNDING
KIT CABLE
\\ ~ -'--, "'-, ./:#2 AWG BCW TD ~ '-::_ . . (CIGBE)
, ... -. '\ \
-, \ \ #2 AWG BCW TD
b \ I I i / (CIGBE)
4 GPS ANTENNA GROUNDING TYP. SCALE
NT.S.
TYPE NC
TfPE VB
0
0 /~C~
'1I/
TYPE GL LUG
TYPE PG
/!#,,lie/;\
\l I 'r\l I W"l
I
llUl llUl
TYPE PH
TYPE GR
TYPE PC
BOLT GROUND
ROD CLAMP
2 HOLE LUG
"u" BOLT PIPE
CLAMP
2 BOLT
PARALLEL
SPLiCER
CAST "T"
SPLICER
CROSS RUN
CLAMP
1 BOLT
PARALLEL
SPLICER
1 BOLT
PARALLEL CLAMP
2
5
SCALE 8 ---NT.S.
NOTES:
1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND
ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR
2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS
SUPPLIED OR RECOMMENDED BY CABLE MFR
3. WEATHER PROOFING SHALL BE TYPE AND PART NUME1ER
AS SUPPUED OR RECOMMENDED BY THE CABLE MFR
I I
[Q QI
--STRIP OUTER JACKET AWAY
USING APPROVED TOOLS
~-OUTER JACKET OF COAXIAL
CABLE
~-SHIELD
In\ '"
\_ GROUND KIT CLAMP PER
MFR SPECIFICATIONS
~------#6 AWG STRANDED
lo o IJ 11 1 ...
GROUNDING KIT
ANTENNA
I
COPPER GROUND WIRE
(GROUNDED TO GROUND
BAR PER NOTES 1 AND 2)
\_ WEATHERPROOFING PER
MFR SEE NOTE 3
#6 AWG STRANDED
COPF'ER GROUND WIRE
(GROUNDED TO GROUND
BAR PER NOTES 1 AND 2)
SCALE
NT.S.
12" TO 24"
2 11/16" r/J MAX.
I
6
WEATHERPROOFING KIT-~
(SEE NOTE 3)
CABLE GROUNDING KIT
#6 AWG STRANDED COPPER
GROUND WIRE (GROUNDED TO
GROUND BAR)
(SEE NOTE 1 & 2)
NOTE:
1 DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT WIRE
DOWN TO GROUND BAR.
2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR
RECOMMENDED BY CABLE MANUFACTURER.
3. WEATHER PROOFING SHALL BE (TYPE AND PART NUMBER AS SUPPLIED OR
RECOMMENDED BY CABLE MANUFACTURER.)
GROUND KIT CONN TO ANT GABL SCALE
N.T.S. 9
TO ANTENNA
'
TX1 e, COAX ~ ------1~ JUMPER, TYP. ~~ ~~
rr~ ~
CONNECTOR ~
WEATHERPROOFING ~ l8
KIT, TYP. SEE NOTE ~ :, : ' :
2 I I I I
l I I I Jj_ I I
4 RX1
r-'~ ,u,, I I !l' h : I•
I "1
WEATHERPROOFING KIT, TYP.
ANDREW SUREGROUND
TYPE KIT, TYP ., SEE
~OTE /f6 AWG
_,,,,--,-). : cV :, :.-\,-ANTENNA CABLE TO _.,,,,.,--..Y\f', ..Y'f \ /ANTENNA GROUND BAR, SIMILAR
BTS EQUIPMENT, TfP_-~ --, , TO DETAIL #4 WITHOUT
,-------,!.--1h,i--~--, iNSULATORS. BONDED DIRECTLY
0 0 0 0 ; 8 ° 0 0 TO TOP OF POLE OR TOWER 0 0
oooooooo~
' -·-·-------___,__
NOTE:
1. DD NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT
GROUND WIRE DOWN TO ANTENNA GROUND BAR.
2. WEATHER PROOFING SHALL BE ANDREW TWO-PART TAPE KIT. COLD
SHRINK SHALL NOT BE USED
GROUNDING KIT SCALE
N.T.S.
1-COPPER GROUND BAR, "X 1/ 4''X 20", NEWTON INSTRUMENT CO. CAT.
NO. B-6142 OR EQUAL. HOLE CENTERS TO MATCH NEMA DOUBLE LUG
CONFIGURATION. (ACTUAL GROUND BAR SIZE WILL VARY BASED ON NUMBER
OF GROUND CONNECTIONS)
2-INSULATORS, NEWTON INSTRUMENT CAT. NO. 3061-4 OR EQUAL
3-5/8" LOCKWASHERS, NEWTON INSTRUMENT CO. CAT. NO. 3015-8
OR EQUAL
4-WALL MOUNTING BRACKET, NEWTON INSTRUMENT CO. CAT NO. A-6056
OR EQUAL
5-5/8-11 X 1" HHCS BOLTS, NEWTON INSTRUMENT CO. CAT NO.
3012-1 OR EQUAL
6-INSULATORS SHALL BE ELIMINATED WHEN BONDING DIRECTLY TO
TOWER/MONOPOLE STRUCTURE. CONNECTION TO TOWER/MONOPOLE
STRUCTURE SHALL BE PER lvlANUFACTURERS RECOMMENDATIONS
I NOTE: ALL HARDWARE SHALL BE STAINLESS STEEL I
GROUND BAR DETAIL
#2 AWG FROM
EQUIPMENT TO BE "'-
GROUNDED ~
~----~,
-;-I
---
SCALE
N.T.S.
~ I ~ ~-..._~---------j' ~--------j'~~ ---i • , ' I ,---
0 LJAL CADWELDS, TO BE /-
3
7
-SED WITH # 2 AWG BC 1v,.,_v/
TO GROUND RING
-SILICON SEAL
AT TOP
-/~-
1' OVC SEALTITE·_/
NOTE:
1. CONTRACTOR TO UTILIZE KOPR-SHIELD (THANS & BETTS) ON
ALL LUG CONNECTIONS OR APPROVED EQUAL
2 ALL LUGS TO BE DUAL HOLE LONG BARREL AND CRIMPED
TWICE WITH MFR'S RECOMMENDED TOOL
GROUND BAR CONNECTION SCALE 1 Q 1-----1 NT.S.
·Mobile·
T-MOBILE WEST LLC
THE INFORMATION CONTAINED IN THIS SIT OF
DRAWINGS IS PRDPRIITARY & CONFIDENTIAL TO
T-MOBILE ANY USE OR DISCLOSURE OTHER THAN AS
rT RELATES TO T-MOBILE IS STRICTLY PROHIBITED
ta,•5 INFRASTRUCTURE
P A R rT N E R S
AZ -CA -CO -ID -NM -NV -TX -UT
2030 MAIN STREET, SUITE 200
IRVINE, CA 92614
SITE NUMBER:
SD06088A
SITENAME:
LASFLORES
1096 LAGUNA DRIVE
CARLSBAD, CA 92008
I 1---+--~c----------+---i
0 08/28/19 100% CONSTRUCTION JBE
A 06/21/19 90% CONSTRUCTION JBE
REV DATE DESCRIPTION
IT IS A VIOLATION OF LAW FOR ANY PERSON.
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET TITLE
GROUNDING
DETAILS
SHEET NUMBER
G2