Loading...
HomeMy WebLinkAbout1923 CALLE BARCELONA; 129; CBC2021-0470; PermitPERMIT REPORT (city of Carlsbad Commercial Permit Print Date: 0S/17 /2022 Permit No: CBC2021-0470 Job Address: 1923 CALLE BARCELONA, # 129, CARLSBAD, CA 92009 Status: Closed -Finaled Permit Type: BLDG-Commercial Work Class: Tenant Improvement Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: 2550120400 Track#: $76,043.85 Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: ProjectTitle: FORUM THE Description: GORJANA; COM Tl (1,635 SF) & NEW STORE FRONT Applicant: Property Owner: DEV12010 SUNSHINE PERMIT SERVICE RON JACKSON 8678 SKYRIM DR TREA NW FORUM AT CARLSBAD OWNER LLC 1905 CALLE BARCELONA, # STE 200 CARLSBAD, CA 92009-8451 LAKESIDE, CA 92040 (760) 479-0166 (619) 885-4458 FEE SB1473 -GREEN BUILDING STATE STANDARDS FEE BUILDING PLAN REVIEW-MINOR PROJECTS (PLN) CERTIFICATE OF OCCUPANCY BUILDING PLAN REVIEW -MINOR PROJECTS (LOE) STRONG MOTION -COMMERCIAL (SMIP) COMM/IND Tl -STRUCTURAL BUILDING PLAN CHECK Total Fees: $1,889.89 Total Payments To Date: $1,889.89 Applied: 12/08/2021 Issued: 03/01/2022 Finaled Close Out: 05/17/2022 Inspector: Final Inspection: Contractor: TAlva 05/17/2022 HARDESTY AND ASSOCIATES INC 711 W 17TH ST, # STE D2 COSTA MESA, CA 92627-4338 (949) 723-2230 Balance Due: AMOUNT $4.00 $98.00 $15.00 $194.00 $21.29 $944.00 $613.60 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov ( City of Carlsbad COMMERCIAL BUILDING PERMIT APPLICATION B-2 Plan Checke&:J.~:l/. Q'f70 Est. Value , lfS't G>QO PC Deposit ,k l,/8• ho Date I :z.f, /2,2../ Job Address 1923 Calle Barcelona Suite: 129 APN: 255-012-04 ·-----· Tenant Name #:._G_o..:rJ_an_a ______________ Lot #: Year Bullt: _2_01_0 _______ _ Year Bullt:. __ _ Occupancy:_M __ Construction Type:._V_IB_ Fire sprinklers:f)YESQNO A/C:C:)YESONo BRIEF DESCRIPTION OF WORK: Tenant Improvement, New storefront, walls, ceilings, fixtures; finishes, Electrlcal, Mechanical. Plumbg. Valutation $195,000 0 Addltlon/New: ____________ .New SF and Use,. __________ New SF and Use ______ SF Deck, _______ SF Patio Cover, ________ SF Other (Specify) ___ _ li!Tenant Improvement: _____ SF, Existing Use: _______ Proposed Use: ______ _ 1,6115 SF, Existing Use: Vacant Proposed Use: (M) Jewelry store D Other: ------------------------------------ PRIMARY APPLICANT Name: Ron Jackson Address: 8678 Sky Rim Dr PROPERTY OWNER Name: Northwood Retail, LLC Address: 8080 Park Lane -Ste 600 City: Lakeside State: CA Zip: 92040 City: Dallas State:.:!!_Zlp:._7_52_a_1 __ _ Phone: 619-885-4458 Phone: 760 479-0166 Email: ron@sunshlnepermltservice.com Emal!: mtussey@northwoodretail.com DESIGN PROFESSIONAL CONTRACTOR OF RECORD Name: Sixty First Place Architects Business Name: Hardesty & Associates Address: 7120 E. Indian School Road Address· 711 W. 17th Street· Suite D2 City: Scottsdale State:._AZ _ __,Zlp: 85251 City: Costa Mesa State: CA Zlp:_9_26_2_7 ____ _ Phone: 480 947-6844 Phone: 949 723-2236 Email: scott@slxtyfirstplace.com Emal!: alex@hardestyassoclatas.com Architect State License: _c_1_21_o_9 _________ CSLB License#: 634021 Class:._B ______ _ Carlsbad Business License# (Requlred):_2_2s_s_8 _____ _ APPLICANT CERnFICATION: I certify that I have read the application and state that the above Information Is correct and that the informatlanontheplans ls accurate. I agree to comply with all City ordinances and State laws relating to building construction. NAME (PRINT): _R_o_n_J_a_ck_s_o_n ____ _ &\ 12/06/2021 SIGN: __ ..,'lj::::::1-------DATE:------ 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Emall: Bullding@cartsbadca.gov REV. 10/21 THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _ A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE. (OPTION A): LICENSED CONTRACTOR DECLARATION: I hereby affirm under penalty of per jury that I am I icensed under provisions of Chapter 9 ( commencing with Section 7000) of Division 3 of the Business and Professions Code, and my I icense is in fu// force and effect. I also affirm under penalty of perjury one of the following declarations (CHOOSE ONE/: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. Policy No. _____________________________________________ _ -OR- [il I have and will maintain worker's compensation, as required by Section 3700 of the labor Code, for the performan_ce of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: Everest N atlona) Insurance Company Policy No. CA-JQQQ'J5Q8-? J J Expiration Date: _ __LL.u:,1..,t,._L_ __________ 1 -OR- D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: ________________________ Lender's Address: ________________________ _ CONTRACTOR CERT/FICA T/ON: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roods, and utilities/utility easements. All proposed modifications and/or additions ore clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads easements, and utilities. The existing and proposed use of each building as stated rs true and correct, all easements and other encumbrances to development have been accurately i1~, a e/ed as well as all on site grodmg/s1te preparat,on All improvements ex1stmg on the property were completed m accordance with all regulations m existence at the time of their.~ ess otherwise noted NAME (PRINT): Alex Samsky SIGNATURE:.£:,;f::::::::~;;;::;;:__ ___ DATE: 2/28/22 Note: If the person signing above is an authorized agent for the contractor provide a letter of authorization on contractor letterhead. {OPTION B): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the fo//owing reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). -OR- DI, as owner of the property, am exclusively contracting with licensed contractors to construct the project {Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). -OR-01 am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason: 0 FORM B-61 "Owner Builder Acknowledgement and Verification Form" is required for any permit issued to a property owner. By my signature below I acknowledge that, except for my persona\ residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed contractors. I understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application is submitted or at the following Website: http:/lwww.leginfo.ca.gov/calaw.html. OWNER CERT/FICA TION: The applicant certifies that all documents and plans clearly and accurately shaw oil existing and proposed buildings, structures, access roods, and utilities/utility easements. All proposed modifications and/or additions ore clearly labeled an the site plan. Any potentially existing detail within these plans inconsistent with the site pion ore not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans shaw the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each building as stated is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grodmg/site preparation All improvements existing on the property were completed in accordance with oil regulot1ons in existence at the time of their construction, unless otherwise noted NAME (PRINT): SIGN: _________ DATE: _____ _ Note: If the person signing above is an authorized agent for the property owner include form B-62 signed by property owner. 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov 2 REV. 10/21 PERMIT INSPECTION HISTORY for (CBC2021-0470) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date BLDG-Electrical Final Tuesday, May 17, 2022 Application Date: 12/08/2021 Owner: TREA NW FORUM AT CARLSBAD OWNER LLC Issue Date: 03/01/2022 Subdivision: CARLSBAD TCT#92-08 GREEN VALLEY Expiration Date: 09/19/2022 IVR Number: 37488 Address: 1923 CALLE BARCELONA, # 129 CARLSBAD, CA 92009 Inspection No. Inspection Primary Inspector Status May 17, 2022: 1. Mechanical HVAC, interior tenant improvement remodel, verified air balance report-approved. 2. All other/rest of interior tenant improvement, final mechanical, electrical, plumbing, and structural framing, per approved plans and details -approved. 3. Approved for issuing certificate of occupancy. Reinspection Inspection Yes Page 7 of 7 PERMIT INSPECTION HISTORY for (CBC2021-0470) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status: Closed -Finaled Application Date: 12/08/2021 Issue Date: 03/01/2022 Expiration Date: 09/19/2022 IVR Number: 37488 Owner: TREA NW FORUM AT CARLSBAD OWNER LLC Subdivision: CARLSBAD TCT#92-08 GREEN VALLEY Address: 1923 CALLE BARCELONA, # 129 CARLSBAD, CA 92009 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final Tuesday, May 17, 2022 COMMENTS April 28, 2022: interior tenant improvement-TCO. Temporary certificate of occupancy. a) mechanical air balance report - required. 1. Title 24 lighting and energy report Verified and approved. 2. Final inspections for MEPS, mechanical, electrical, plumbing, and structural, scope of work-approved per plan. 3. Rest of interior tenant improvement inspection-OK. 4. Title 24 ADA compliant-approved Per plan. May 17, 2022: 1. Mechanical HVAC, interior tenant improvement remodel, verified air balance report-approved. 2. All other/rest of interior tenant improvement, final mechanical, electrical, plumbing, and structural framing, per approved plans and details -approved. 3. Approved for issuing certificate of occupancy. May 17, 2022 1. Mechanical HVAC, interior tenant improvement remodel, verified air balance report-approved. 2. All other/rest of interior tenant improvement, final mechanical, electrical, plumbing, and structural framing, per approved plans and details -approved. 3. Approved for issuing certificate of occupancy. May 17, 2022: 1. Mechanical HVAC, interior tenant improvement remodel, verified air balance report-approved. 2. All other/rest of interior tenant improvement, final mechanical, electrical, plumbing, and structural framing, per approved plans and details -approved. 3. Approved for issuing certificate of occupancy. Passed No Yes Yes Yes Page 6 of7 PERMIT INSPECTION HISTORY for (CBC2021-0470) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status: Scheduled Date 05/17/2022 Closed -Finaled Actual Inspection Type Start Date BLDG-Structural Final BLOG-Electrical Final 05/17/2022 BLDG-Final Inspection Tuesday, May 17, 2022 Application Date: 12/08/2021 Owner: TREA NW FORUM AT CARLSBAD OWNER LLC Issue Date: 03/01/2022 Subdivision: CARLSBAD TCT#92-08 GREEN VALLEY Expiration Date: 09/19/2022 IVR Number: 37488 Address: 1923 CALLE BARCELONA, # 129 CARLSBAD, CA 92009 Inspection No. Inspection Status April 28, 2022: interior tenant improvement-TCO. Primary Inspector Temporary certificate of occupancy. a) mechanical air balance report - required. 1. Title 24 lighting and energy report Verified and approved. 2. Final inspections for MEPS, mechanical, electrical, plumbing, and structural, scope of work-approved per plan. 3. Rest of interior tenant improvement inspection-OK. 4. Title 24 ADA compliant-approved Per plan. April 28, 2022: interior tenant improvement~TCO. Temporary certificate of occupancy. a) mechanical air balance report - required. 1. Title 24 lighting and energy report Verified and approved. 2. Final inspections for MEPS, mechan·Ical, electrical, plumbing, and structural, scope of work-approved per plan. 3. Rest of interior tenant improvement inspection-OK. 4. Title 24 ADA compliant-approved Per plan. 182921-2022 Passed Tony Alvarado Reinspection Inspection Yes Yes Complete Page 5 of 7 PERMIT INSPECTION HISTORY for (CBC2021-0470) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status: Closed -Finaled Application Date: 1210812021 Issue Date: 0310112022 Expiration Date: 09/1912022 IVR Number: 37488 Owner: TREA NW FORUM AT CARLSBAD OWNER LLC Subdivision: CARLSBAD TCT#92-08 GREEN VALLEY Address: 1923 CALLE BARCELONA, # 129 CARLSBAD, CA 92009 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final Tuesday, May 17, 2022 COMMENTS April 28, 2022: interior tenant improvement-TCO. Temporary certificate of occupancy. a) mechanical air balance report - required. 1. Title 24 lighting and energy report Verified and approved. 2. Final inspections for MEPS, mechanical, electrical, plumbing, and structural, scope of work-approved per plan. 3. Rest of interior tenant improvement inspection-OK. 4. Title 24 ADA compliant-approved Per plan. April 28, 2022: interior tenant improvement-TCO. Temporary certificate of occupancy. a) mechanical air balance report - required. 1. Title 24 lighting and energy report Verified and approved. 2. Final inspections for MEPS, mechanical, electrical, plumbing, and structural, scope of work-approved per plan 3. Rest of interior tenant improvement inspection-OK. 4. Title 24 ADA compliant-approved Per plan. April 28, 2022: interior tenant improvement-TCO. Temporary certificate of occupancy. a) mechanical air balance report - required. 1. Title 24 lighting and energy report Verified and approved. 2. Final inspections for MEPS, mechanical, electrical, plumbing, and structural, scope of work-approved per plan. 3. Rest of interior tenant improvement inspection-OK. 4. Title 24 ADA compliant-approved Per plan. Passed Yes Yes Yes Page 4 of 7 PERMIT INSPECTION HISTORY for {CBC2021-0470) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status: Scheduled Date 03/23/2022 Closed -Finaled Actual Inspection Type Start Date 03/23/2022 BLDG-44 Rough-Ducts-Dampers BLDG-82 Drywall, Exterior Lath, Gas Test, Hot Mop Checklist Item Application Date: 12/08/2021 Owner: TREA NW FORUM AT CARLSBAD OWNER LLC Issue Date: 03/01/2022 Subdivision: CARLSBAD TCT#92-08 GREEN VALLEY Expiration Date: 09/19/2022 IVR Number: 37488 Address: 1923 CALLE BARCELONA, # 129 CARLSBAD, CA 92009 Inspection No. Inspection Primary Inspector Status March 17, 2022:(Partial Pass). 1. Temporary certificate of occupancy for Zumiez interior tenant improvement-(Partial pass). 2. TCO approved for the following: a) training employees. b) stocking shelves. c) equipment set-up an installation. 3. PENDING:Mechanical HVAC unit requiref air balance report or commission. 4. Rest of tenant improvement interior work -OK. 6. Minimal Drywall patching and minimal T-bar grid ceiling scope of work per plan-approved. 178924-2022 Passed Tony Alvarado COMMENTS Reinspection Inspection Yes Complete Passed BLDG-17 Interior Lath-Drywall Yes 04/28/2022 04/28/2022 BLDG-Final Inspection 181543-2022 Partial Pass Tony Alvarado Reinspection Incomplete Tuesday, May 17, 2022 Page 3 of 7 PERMIT INSPECTION HISTORY for (CBC2021-0470) Permit Type; BLDG-Commercial Application Date: 12/08/2021 Owner: TREA NW FORUM AT CARLSBAD OWNER LLC Work Class: Tenant Improvement Issue Date: 03/01/2022 Subdivision: CARLSBAD TCT#92-08 GREEN VALLEY Status: Scheduled Date Closed -Finaled Expiration Date: 09/19/2022 IVR Number: 37488 Address: 1923 CALLE BARCELONA, # 129 CARLSBAD, CA 92009 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-34 Rough Electrical COMMENTS March 17, 2022:(Partial Pass). 1. Temporary certificate of occupancy for Zumiez interior tenant improvement-(Partial pass). 2. TCO approved for the following: a) training employees. b) stocking shelves. c) equipment set-up an installation. 3. PENDING:Mechanical HVAC unit requireE air balance report or commission. 4. Rest of tenant improvement interior work -OK. 6. Minimal Drywall patching and minimal T-bar grid ceiling scope of work per plan-approved. March 17, 2022:(Partial Pass). 1. Temporary certificate of occupancy for Zumiez interior tenant improvement-(Partial pass). 2. TCO approved for the following: a) training employees. b) stocking shelves. c) equipment set-up an installation. 3. PENDING:Mechanical HVAC unit requiref air balance report or commission. 4. Rest of tenant improvement interior work -OK. 6. Minimal Drywall patching and minimal T-bar grid ceiling scope of work per plan-approved. March 17, 2022:(Partial Pass). 1. Temporary certificate of occupancy for Zumiez interior tenant improvement-(Partial pass). 2. TCO approved for the following: a) training employees. b) stocking shelves. c) equipment set-up an installation. 3. PENDING:Mechanical HVAC unit require~ air balance report or commission. 4. Rest of tenant improvement interior work -OK. 6. Minimal Drywall patching and minimal T-bar grid ceiling scope of work per plan-approved. Reinspection Inspection Passed Yes Yes Yes Tuesday, May 17, 2022 Page 2 of 7 Building Permit Inspection History Finaled ( City of Carlsbad Permit Type: Work Class: Status: Scheduled Date 03/03/2022 03/17/2022 PERMIT INSPECTION HISTORY for (CBC2021-0470) BLDG-Commercial Application Date: 12/08/2021 Owner: TREA NW FORUM AT CARLSBAD OWNER LLC Tenant Improvement Issue Date: 03/01/2022 Subdivision: CARLSBAD TCT#92-08 GREEN VALLEY Closed -Finaled Expiration Date: 09/19/2022 Address: 1923 CALLE BARCELONA, # 129 CARLSBAD, CA 92009 Actual Start Date 03/03/2022 03/17/2022 IVR Number: 37488 Inspection Type Inspection No. Inspection Primary Inspector Status BLDG-21 177636-2022 Passed Tony Alvarado Underground/Underflo or Plumbing Checklist Item COMMENTS BLDG-Building Deficiency March 3, 2022: 1. Duck sealant-approved. 2. Underground plumbing under water leak test pressure test-approved. 3. Rough top out plumbing Jines, under water leak pressure test-approved. BLDG-24 Rough/Topout 177637-2022 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS March 3, 2022: 1. Duck sealant-approved. 2. Underground plumbing under water leak test pressure test-approved. 3. Rough top out plumbing lines, under water leak pressure test-approved. BLDG-44 Rough/Ducts/Dampers 177638-2022 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS March 3, 2022: 1. Mechanical Dud sealant-approved. 2. Underground plumbing under water leak test pressure test-approved. 3. Rough top out plumbing lines, under water leak pressure test-approved. BLDG-84 Rough 178679-2022 Passed Tony Alvarado Combo(14,24,34,44) Checklist Item COMMENTS BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers BLDG-85 T-Bar, Ceiling 178653-2022 Passed Tony Alvarado Grids, Overhead Reinspection Inspection Complete Passed Yes Complete Passed Yes Complete Passed Yes Complete Passed Yes Yes Yes Yes Complete Tuesday, May 17, 2022 Pago 1 of 7 • lW INTERWEST DATE: 2/3/2022 JURISDICTION: City of Carlsbad PLAN CHECK#.: CB-CBC2021-0470.RC1 PROJECT ADDRESS: 1923 Calle Barcelona PROJECT NAME: Gorjana T. I. SET II D APPLICANT D JURIS. [g] The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The check list transmitted herewith is for the applicant's information. The plans are being held at lnterwest until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to the jurisdiction at: Ron Jackson [g] lnterwest staff did not advise the applicant that the plan check has been completed. D lnterwest staff did advise the applicant that the plan check has been completed. Person contacted: Ron Jackson Telephone#: 619-885-4458 Date contacted: (by: ) Email: ron@sunshinepermitservice.com Mail Telephone Fax In Person [g] REMARKS: City to field verify that the path of travel from the handicapped parking space to the T. I. area and the bathroom serving the T. I. area comply with all the current disabled access requirements. By: David Yao lnterwest 1/27/2022 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 ·' • lW INTERWEST DATE: 12/28/2021 JURISDICTION: City of Carlsbad PLAN CHECK#.: CB-CBC2021-0470 PROJECT ADDRESS: 1923 Calle Barcelona PROJECT NAME: Gorjana T. I. SETI □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. ~ The check list transmitted herewith is for the applicant's information. The plans are being held at lnterwest until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to the jurisdiction at: Ron Jackson D lnterwest staff did not advise the applicant that the plan check has been completed. ~ lnterwest staff did advise the applicant that the plan check has been completed. Person contacted: Ron Jackson Telephone#: 619-885-4458 Date contacted: Mail Telephone 0 REMARKS: By: David Yao lnterwest (by: ) Email: ron@sunshinepermitservice.com Fax In Person Enclosures: 12/9/2021 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 City of Carlsbad CB-CBC2021-0470 12/28/2021 PLAN REVIEW CORRECTION LIST COMMERCIAL PLAN CHECK#.: CB-CBC2021-0470 JURISDICTION: City of Carlsbad OCCUPANCY: M USE: retail TYPE OF CONSTRUCTION: VB ACTUAL AREA: T. I. 1635 sf ALLOWABLE FLOOR AREA: STORIES: 1 HEIGHT: SPRINKLERS?: Y REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 12/28/2021 FOREWORD (PLEASE READ): OCCUPANT LOAD: ~21 DATE PLANS RECEIVED BY ESGIL CORPORATION: 12/9/2021 PLAN REVIEWER: David Yao This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2019 CBC, which adopts the 2018 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2018 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad CB-CBC2021-0470 12/28/2021 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to lnterwest and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to lnterwest, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to lnterwest only will not be reviewed by the City Planning, Engineering and Fire Departments until review by lnterwest is complete. CARLSBAD CLIMATE ACTION PLAN: (APPLICABLE ONLY WHEN THE PLANS COME WITH THE B-50 APPLICATION FILLED OUT AND MUST HAVE B-55 FORM ON PLANS.) City of Carlsbad requires that all projects that qualify for CAP compliance will require a completed Climate Action Plan (CAP) Consistency Checklist (citv form B-50) to be completed by the APPLICANT. For plans submitted to the City the following Climate Action Plan requirements apply, per Carlsbad ordinance: A. The applicant is to fill out the B-50 CAP Consistency Checklist. The scope of work and project valuation will determine which sections of the CAP are required. B. Plan examiners review the B-50 CAP Consistency Checklist for completion. For example: If new residential construction is the scope of work, CAP sections 2A, 3A, and 4A are required to be filled on the B-50 checklist. C. Only for projects that require CAP compliance: DO NOT APPROVE THE PLANS UNTIL THE B-55 CAP PLAN TEMPLATE IS COMPLETED (MATCHING THE B-50 APPLICATION) AND IMPRINTE.D ONTO THE PLANS. THE B-55 FORM IS LOCATED AT THE END OF THE B-50 FORM. City of Carlsbad CB-CBC2021-0470 12/28/2021 1. Provide item-by-item responses on an 8-1/2-inch by 11-inch sheet(s) clearly and specifically indicating where and how each correction item has been addressed (vague responses, such as "Done" or "See plans," are unacceptable). 2. Sheet A 1.1 does not clearly reference the storefront detail to 1/A4.1. Please add the information on the plan. 3. Please refer the section for 1/A4.1 to A4.2. 4. Per California law, additions or alternations of Commercial projects or Multifamily Residential projects (condos, apartments and hotels with kitchens) available for use before January 1, 1994 may require replacement of noncompliant plumbing fixtures *** by water conserving fixtures: • All plumbing fixtures in the building where an addition will increase the floor area of the building by 10%. (Or) • Plumbing fixtures that serve the alternations or improvement in which the building permit valuation exceeds $150,000.00. (Or) • An alternation or improvement to a room containing noncompliant fixtures (regardless of valuation). Please note on the plans the specific plumbing fixtures requiring replacement. *** "Noncompliant plumbing fixtures" are any of the following: • Any water closet exceeding 1.6 gallons/flush. • Any urinal manufactured to use more than 1.0 gallon/flush. • Any showerhead exceeding 2.5 gallon/minute. • Any interior faucet that emits more than a 2.2 gallons/minute. 5. Provide notes and details on the plans to show compliance with the enclosed "Disabled Access" Review List. 6. PME is O.K. 7. Please provide a response list indicating where each correction item has been addressed on the plans. I.e., specify the plan sheet, note, or detail number, calculation page, etc., where the item is corrected on the plans. 8. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: □ Yes □ No 9. The jurisdiction has contracted with lnterwest, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Error! Reference source not found. at lnterwest. Thank you. City of Carlsbad CB-CBC2021-0470 i2/28/2021 DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT-TITLE 24 The following disabled access items are taken from the 2019 edition of California Building Code, Title 24. Per Section 1.9.1, all publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities. REMODELS, ADDITIONS AND REPAIRS 1. When alterations, structural repairs or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the following requirements, per Section 11 B-202.4: • The area of specific alteration, repair or addition must comply as "new" construction. • A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. • The path of travel shall include the existing parking. 2. If any proposed walks slope >1 :20 (5%) they must comply with ramp requirements, per Section 11 B-402.2. 3. Walks along an accessible route of travel are required to be ~48" minimum in width and have slip resistant surfaces, per Section 11 B-403.5.1, Exception 3. 4. Show that a 60" x 60" level area is provided at areas where a door (or gate) swings toward the walk in the accessible route of travel, per Section 11 B-404.2.4. Show that the walk extends ~24" beyond the strike edge of the strike edge of any door (or gate) that swings toward the walk. 5. Show, or note, that there is a level floor or landing on each side of all doors. The floor or landing is to be S½'' lower than the doorway threshold, per Section 11 B- 404.2.5. 6. Show or note that all hand-activated door opening hardware meets the following requirements, per Section 11 B-404.2. 7: Please clarify how the hardware for barn door D2 comply with the requirement? a) Latching, or locking, doors in a path of travel are operated with a single effort by lever type hardware, by panic bars, push-pull activating bars, or other hardware designed to provide passage without requiring the ability to grasp the opening hardware. 7. Show that the minimum strike edge distances are provided at the level area on the side to which a door (or a gate) swings, per Section 11 B-404.2.4: a) ~24" at exterior conditions. 8. Show a level area, or landing, per Section 11 B-404.2.4: City of Carlsbad CB-CBC2021-0470 12/28/2021 a) 260" in the direction of door swing. b) 248" in the direction opposite the door swing (or 44" if doors don not have latches or closers). 9. Show or note that the proposed general sales, display and office areas are accessible, as follows: (if applicable) a) Checkstands shall comply with the following: b) i) Where regular checkstands are provided, the number of accessible checkstands shall be as follows, per table 11 B-227.2: a) 21 but ~4 regular total = 1 accessible. Accessible checkstands shall provide a clear check-out aisle width of 36" with an adjoining counter ~38" above finished floor. END OF DOCUMENT City of Carlsbad CB-CBC202 l-0470 12/2S/2021 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: David Yao BUILDING ADDRESS: 1923 Calle Barcelona BUILDING OCCUPANCY: M BUILDING PORTION T.I. Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code Id ,Per i Feeb Or. B g mt y d1na I tJ '/I AREA Valuation ( Sq. Ft.) Multiplier 1635 cb nee .... Plan Check Fee by Ordinance • Type of Review: D Repetitive Fee ..,. Repeats Comments: [7] Complete Review □ Other D Hour1y EsGil Fee PLAN CHECK#.: CB-CBC2021-0470 DATE: 12/28/2021 Reg. VALUE ($) Mod. D Structural Only $613.601 Sheet of