HomeMy WebLinkAbout2643 GALICIA WAY; ; CBR2020-3334; PermitPERMIT REPORT Residential Permit Print Date: 05/26/2022 Job Address: 2643 GALICIA WAY, CARLSBAD, CA 92009-8125 Permit Type: BLDG-Residential Work Class: Alteration Parcel#: 2161803100 Track#: Valuation: $87,485.31 Lot#: Occupancy Group: Project#: #of Dwelling Units: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Project Title: Description: PACHECO: 1881 SF INTERIOR REMODEL Applicant: Property Owner: PERMITS IN MOTION TERRY MONTELLO 415 60TH ST PACHECO ALBERT AND SUSAN 2006 TRUST 2643 GALICIA WAY SAN DEIGO, CA 92115 (619) 994-5557 FEE STRONG MOTION-RESIDENTIAL BUILDING PLAN CHECK FEE (BLDG) CARLSBAD, CA 92009 SB1473 GREEN BUILDING STATE STANDARDS FEE BUILDING PERMIT FEE ($2000+) ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL Total Fees: $1,114.75 Total Payments To Date: $1,114.75 ( City of Carlsbad Permit No: CBR2020-3334 Status: Closed -Finaled Applied: 12/21/2020 Issued: 04/06/2021 Finaled Close Out: 05/17/2022 Inspector: Final Inspection; Balance Due: CRenf 05/17/2022 AMOUNT $11.37 $402.04 $4.00 $574.34 $43.00 $80.00 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov ('City of Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Job Address 2643 GALICIA WAY Suite: ____ APN: 216-180-31-00 CT/Project#:. _________________ Lot#:. ___ _ Fire Sprinklers: OYES ONO Air Conditioning: OYES ONO Electrical Panel Upgrade:O YES O NO BRIEF DESCRIPTION OF WORK: iNTERIOR REMODEL ( KITCHEN,LIVING ROOM,BATHROOMS AND GARAGE) 0 Addition/New: _____ Living SF, ____ Deck SF, ____ Patio SF, ____ Garage SF Is this to create an Accessory Dwelling Unit? 0 Y ON New Fireplace? 0 Y O N, if yes how many? __ 0Remodel: _1_8_8_1 ___ SF of affected area Is the area a conversion or change of use? 0 Y ON 0 Pool/Spa: ____ SF Additional Gas or Electrical Features? ____________ _ osolar: ---KW, --Modules, Mounted:ORoof OGround, Tilt:O vO N, RMA: Ov ON, Battery:OY ON, Panel Upgrade: Ov ON D Reroof: ________________________________ _ D Plumbing/Mechanical/Electrical Only: _______________________ _ D Other: _______________________________ _ APPLICANT (PRIMARY CONTACT) Name: TERRY MONTELLOL Address: 4715 60THS ST City: SAN DIEGO State:~Zip: 92115 Phone: 619994~:[S-5".,Z. Email: PERMITS@PERMITSINMOTION.COM DESIGN PROFESSIONAL Name: SAME AS CONTRACTOR Address: ________________ _ City: ________ State: ___ Zip: ____ _ Phone: ________________ _ Email: _________________ _ PROPERTY OWNER Name: AL&SUSAN PACHECO Address: 2643 GALICIA WAY City: CARLSBAD State:~Zip: _92_0~0_9 __ Phone: ___________________ _ Email: ___________________ _ CONTRACTOR BUSINESS Name: JACKSON DESIGN Address: 4797 MERCURY ST City: SAN DIEGO State:~Zip: _92_1_1_1 ___ _ Phone: 6194426125 Email: __________________ _ Architect State license: . . State license: 880939 Bu~cense: plt).>l:1/ CX 1 ;2 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolisH or repair any structure, pri6r t ~ issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's license law {Chapter 9, commending with Section 7000 of Dlvtsion 3 of the Business and Professions Code} or that he/she is e)(empt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any apphcant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-1 Page 1 of 2 Rev. 06/18 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: 01 have and will maintain a certificate of consent to self"insure for workers' compensation provided by Section 3700 of the labor Code, for the performance of the work which this permit Is issued, [i]1 have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation inrnrance carrier and policy number are: Insurance Company Name: _,_,._1"_w_m_p~------------------ Policy No. ·9072929 Expiration Date: _1_0,_01_12_0_2_1 _______ _ 0 Certificate of Exemption; I certify that in the performance of the work for which this permit is Issued, I shall not employ any person in any manner .~o as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subJect an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, Interest and attorney's fees. CONTRACTOR SIGNATURE: T}n lJAGENT DATE: 04-06-2021 -------------------- ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor$s License Law for the fo/Jowing reason: O I, as owner of the property or my employees with wages as their sole compensation, wilt do the work and the structure is not Intended or offered for safe (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sate. If, however, the building or improvement is sold within one year of completion, the owner-builder wi!J have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License law does not apply to an owner of property who buikls or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License law). 0 I am exempt under Section ________ Business and Professions Code for this reason; 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. QYES Q NO 2 I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person !firm) to provide the proposed construction (include name address/ phone/ contractors' license number}: 4. 1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): S. l will provide some of the work, but I have contracted (hired} the following persons to provide the work indicated (include name/ address/ phone/ type of work): OWNER SIGNATURE: □AGENT DATE: _____ _ -------------------- CONSTRUCTION LENDING AGENCY, IF ANY: l hereby affirm that there is a construction !ending agency for the performance of the work this permit is issued {Sec. 3097 (i) Civil Code). ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutelv hazardous materials registration form or risk management and prevention program under Sections 2550S, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? I Yes/ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes/ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes/ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES ANO THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that! have read the application and state that the above information is correct and that the information on the plans is accurate.! agree to comply with al! City ordinances and State laws relating to building construction. I hereby authorize representative ofthe City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY ANO KEEP HARMLESS THE CITY OF CARLSBADAGAINSl All UABILITIE:5, JUDGMENTS, COSTSANDEXPENSES WHICH MAY JN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit fs required for excavations over S'O' deep and demolition or construction of structures over 3 stories m height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by !imitation and become null and void if the building or work authorized by such permit ls not commenced within 180 days from the date of such permit or if the building or work authori1ed by such permit is suspended or abandoned at any time after the wo,k is commenced to, a period of 180 days. C~ APPLICANT SIGNATURE: ~~ DATE: / 2 It 7 I 1635 Faraday Ave Carlsbad, CA 92008 B-1 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of 2 Email: Building@carlsbadca.gov Rev. 06/18 PERMIT INSPECTION HISTORY for (CBR2020-3334) Permit Type: BLDG-Residential Work Class: Alteration Status: Closed -Finaled Application Date: 1212112020 Owner: TRUST PACHECO ALBERT AND SUSAN 2006 TRUST Issue Date: 04/06/2021 Subdivision: LA COSTA-SOUTH UNIT# 1 Expiration Date: 01126/2022 IVR Number: 30603 Address: 2643 GALICIA WAY CARLSBAD, CA 92009-8125 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Thursday, May 26, 2022 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final COMMENTS Status Passed Yes Yes Yes Yes Yes Page 4 of 4 PERMIT INSPECTION HISTORY for (CBR2020-3334) Permit Type: BLDG-Residential Application Date: 12/21/2020 Owner: TRUST PACHECO ALBERT AND SUSAN 2006 TRUST Work Class: Alteration Issue Date: 04/06/2021 Subdivision: LA COSTA-SOUTH UNIT# 1 Status: Closed -Finaled Expiration Date: 01/26/2022 Address: 2643 GALICIA WAY IVR Number: 30603 CARLSBAD, CA 92009-8125 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection 07/23/2021 07/30/2021 01/07/2022 01/10/2022 05/17/2022 Checklist Item BLDG-Building Deficiency COMMENTS July 21, 2021: virtual Inspection. 1. No title 24 energy efficient, mandatory energy measure-installat'Ion Deficiencies. 2. Verified installation of new energy efficient, title 24 mandatory energy measures, scope of work -approved. 07/23/2021 BLDG-13 Shear Panels/HD (ok to wrap) 162717-2021 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS July 23, 2021: 1. No interior shearwall, method of attachment deficiendes. 2. (4) interior shear wall diaphragm: type, size, and method of attachment anchoring system, per engineer plans and detail table specifications -approved. 07/30/2021 BLDG-17 Interior Lath/Drywall 163332-2021 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS July 30, 2021: 1. No drywall building Deficiencies. 2. Gypsum board/drywall: type, size, a method of attachment anchoring, per structural engineered plans detail specifications-approved. 01/07/2022 BLDG-34 Rough Electrical 174167-2022 Cancelled Tony Alvarado Checklist Item COMMENTS BLDG-Building Deficiency Cancel new panel not ready, ground rods UFER ground not located BLDG-Electric Meter Release Checklist Item 174140-2022 COMMENTS BLDG-Building Deficiency Not grounded 01/10/2022 BLDG-Electric Meter Release Checklist Item 174173-2022 COMMENTS BLDG-Building Deficiency 05/17/2022 BLDG-Final Inspection 182845-2022 Failed Peter Dreibelbis Passed Chris Renfro Passed Chris Renfro Thursday, May 26, 2022 Passed Yes Complete Passed Yes Complete Passed Yes Reinspection Incomplete Passed No Reinspection Incomplete Passed No Complete Passed Yes Complete Page 3 of 4 PERMIT INSPECTION HISTORY for (CBR2020-3334) Permit Type: BLDG-Residential Application Date: 12/21/2020 Owner: TRUST PACHECO ALBERT AND SUSAN 2006 TRUST Work Class: Alteration Issue Date: 04/06/2021 Subdivision: LA COSTA-SOUTH UNIT# 1 Status: Scheduled Date 07/21/2021 Closed -Finaled Expiration Date: 01/26/2022 Address: 2643 GALICIA WAY IVR Number: 30603 CARLSBAD, CA 92009-8125 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers COMMENTS July 16, 2021: 1. No rough frame combination/building deficiencies. 2. Structural, plumbing, electrical, and mechanical, scope of work per structural and architectural plans and detail s pecificatio ns-ap proved . 3. Plumbing gas line, under air pressure leak test-approved. 4. Tub and shower enclosures-shower pans. hot-mop installation, under water leak test-approved. July 16, 2021: 1. No rough frame combination/building deficiencies. 2. Structural, plumbing, electrical, and mechanical, scope of work per structural and architectural plans and detail specifications-approved. 3. Plumbing gas line, under air pressure leak test-approved. 4. Tub and shower enclosures-shower pans, hot-mop installation, under water leak test-approved. July 16, 2021: 1. No rough frame combination/building deficiencies. 2. Structural, plumbing, electrical, and mechanical, scope of work per structural and architectural plans and detail specifications-approved. 3. Plumbing gas line, under air pressure leak test-approved. 4. Tub and shower enclosures-shower pans, hot-mop installation, under water leak test-approved. July 16, 2021: 1. No rough frame combination/building deficiencies. 2. Structural, plumbing, electrical. and mechanical, scope of work per structural and architectural plans and detail specifications-approved. 3. Plumbing gas line, under air pressure leak test-approved. 4. Tub and shower enclosures-shower pans, hot-mop installation, under water leak test-approved. 07/21/2021 BLDG-16 Insulation 162546-2021 Passed Tony Alvarado Passed Yes Yes Yes Yes Complete Thursday, May 26, 2022 Page 2 of 4 Building Permit Inspection History Finaled {_City of Carlsbad PERMIT INSPECTION HISTORY for {CBR2020-3334) Permit Type: BLDG-Residential Work Class: Alteration Status: Closed -Finaled Scheduled Actual Inspection Type Date Start Date 04/20/2021 04/20/2021 BLDG-21 Underground/Underflo or Plumbing Checklist Item Application Date: 12/21/2020 Owner: TRUST PACHECO ALBERT AND SUSAN 2006 TRUST Issue Date: 04/06/2021 Subdivision: LA COSTA-SOUTH UNIT# 1 Expiration Date: 01/26/2022 Address: 2643 GALICIA WAY IVR Number: 30603 CARLSBAD, CA 92009-8125 Inspection No. Inspection Primary Inspector Reinspection Inspection Status 155432-2021 Passed Chris Renfro Complete COMMENTS Passed BLDG-Building Deficiency Yes 04/30/2021 05/03/2021 07/16/2021 04/30/2021 BLDG-24 Rough/Topout 156355-2021 Cancelled Chris Renfro Checklist Item COMMENTS BLDG-Building Deficiency Cancelled per contractor 05/03/2021 BLDG-11 156530-2021 Passed Tony Alvarado Foundation/Ftg/Plers (Robar) Checklist Item BLDG-Building Deficiency COMMENTS May 3, 2021: 1. No interior footing steel reinforcement Building Deficiencies. 2. Existing Underground plumbing, under 10' ft. high head pressure water leak test scope of work-Approved. 3. Footing/foundation steel reinforcement per structural engineers sheet SD-2/detail #3, and detail #6-approved. 4. Scope of all foundation/footing steel layout specifications, per structural engineers plan and detail table specifications-approved. 07/16/2021 BLDG-84 Rough Combo(14,24,34,44) 162123-2021 Passed Tony Alvarado Thursday, May 26, 2022 Reinspection Incomplete Passed No Complete Passed Yes Complete Page 1 of4 ✓• EsG1I DATE: 3/22/2021 D APPLICANT D JURIS. JURISDICTION: Carlsbad PLAN CHECK#.: cbR2020-3334 PROJECT ADDRESS: 2643 Galicia Way PROJECT NAME: Interior Remodel for SFR SET III ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Email: Mail Telephone Fax In Person 0 REMARKS: By: Richard Moreno. Phone: 858-345-6435 EsGil 3/11/2021 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 ' DATE: 2/3/2021 JURISDICTION: Carlsbad PLAN CHECK#.: cbR2020-3334 ✓• EsG1I SET II PROJECT ADDRESS: 2643 Galicia Way PROJECT NAME: Interior Remodel for SFR □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Terry Montello D EsGil staff did not advise the applicant that the plan check has been completed. ~ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Terry Montello Telephone#: (619) 994-5557 Date contacted: (by: ) Email: permits@permitsinmotion.com Mail Telephone Fax In Person 0 REMARKS: By: Richard Moreno. Phone: 858-345-6435 EsGil Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad cbR2020-3334 2/3/2021 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. PLANS 1. The following note should be given with each correction list: Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Note or provide the following design requirements for gas water heaters installed to serve individual dwelling units: ES 150.0(n) Gas piping sizing based upon a minimum input of 200,000 btu/hr. PC: Please provide gas line design for review MISCELLANEOUS To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: , ' Carlsbad cbR2020-3334 2/3/2021 Yes □ No □ The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Richard Moreno. Phone: 858-345-6435 at EsGil. Thank you. • DATE: 1/11/2021 JURISDICTION: Carlsbad PLAN CHECK#.: cbR2020-3334 ✓• EsG1I SETI PROJECT ADDRESS: 2643 Galicia Way PROJECT NAME: Interior Remodel for SFR D APPLICANT D JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [8J The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [8J The applicant's copy of the check list has been sent to: Terry Montello D EsGil staff did not advise the applicant that the plan check has been completed. [8J EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Terry Montello Telephone#: (619) 994-5557 Date contacted: (by: Email: permits@permitsinmotion.com Mail Telephone Fax In Person 0 REMARKS: By: Richard Moreno. Phone: 858-345-6435 EsGil 2/22/2021 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 ,, Carlsbad cbR2020-3334 1/11/2021 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: cbR2020-3334 PROJECT ADDRESS: 2643 Galicia Way FLOOR AREA: Remodel: 1881 SF REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW 858-345-6435 COMPLETED: 1/11/2021 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad STORIES: 1 HEIGHT: no change DATE PLANS RECEIVED BY ESGIL CORPORATION: 2/22/2021 PLAN REVIEWER: Richard Moreno. Phone: This plan review is limited to the technical requirements contained in the California Residential Code, California Building Code, California Plumbing Code, California Mechanical Code, California I Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2019 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2019 CRC, 2019 CBC, 2019 CPC, 2019 CMC and 2019 CEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2019 California Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy} where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. I Carlsbad cbR2020-3334 1/11/2021 PLANS 1. The following note should be given with each correction list: Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Note or provide the following design requirements for gas water heaters installed to serve individual dwelling units: ES 150.0(n) a) Gas piping sizing based upon a minimum input of 200,000 btu/hr. b) A condensate drain installed no higher than 2" above the base of the heater that also allows for gravity drainage. c) The "B" vent installed in a straight position from the room containing the water heater to the roof termination. (For future possible sleeving for high efficiency heater venting.) d) A 120-volt receptacle accessible to the heater installed within 3'. 4. Detail the dryer exhaust duct design from the dryer to the exterior. The maximum length is 14 feet with a maximum of two 90-degree elbows or provide the manufacturer's duct length specification description on the plans: Include the dryer specifications (manufacturer, model, and fuel type) as well as the duct description (size and type). CMC Section 504.4.2.1. Residential ventilation requirements: ES 150.0(o)/ASHRAE 62.2 5. Kitchens require exhaust fans with a minimum 100 cfm ducted to the exterior. Detail compliance by including a complying exhaust fan or a ducted range hood to the exterior. Carlsbad cbR2020-3334 1/11/2021 6. Bathrooms require exhaust fans (minimum 50 cfm) to be ducted to the exterior. A bathroom is defined "as a room with a bathtub, shower, or spa or some similar source of moisture". 7. Residential bathroom exhaust fans shall be energy star rated and shall be control by a humidistat capable of an adjustment between 50 and 80% humidity. CalGreen 4.506.1. Exception: Control by a humidistat is not required if the bathroom exhaust fan is also the dwelling whole house ventilation. 8. City of Carlsbad requires that all plans provide completed Climate Action Plan (CAP) Consistency Checklist, city form B-50, and show on title sheet of plans completed CAP template, city form B-55. MISCELLANEOUS 9. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 10. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ 11. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Richard Moreno. Phone: 858-345-6435 at EsGil. Thank you. Carlsbad cbR2020-3334 1/11/2021 [DO NOT PAY-THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK#.: cbR2020-3334 PREPARED BY: Richard Moreno. Phone: 858-345-6435 BUILDING ADDRESS: 2643 Galicia Way BUILDING OCCUPANCY: BUILDING AREA Valuation Reg. PORTION ( Sq. Ft.) Multiplier Mod. remodel 1881 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisd 1ction Code cb By Ordinance 1997 UBC Buildin Permit Fee g ... 1997 USC Plan Check Fee .., DATE: 1/11/2021 VALUE ($) 87,485 87,485 Type of Review: Complete Review D Structural Only D Repetitive Fee -~..,.-Repeats □ Olhe, D Hourly EsGil Fee f-------11 Hr. @ • Comments: In addition to the above fee, an additional fee of$ $ /hr.) for the CalGreen review. $370.141 is due ( hour@ Sheet of (_ City of Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of permits are not required to fill out this form ❖ Patio 1 ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool _. If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. _. Details on CAP ordinance requirements are available on the city's website. _. A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and download the latest form. BP No.: Property Address/ APN: Applicant Name/Co.: Applicant Address: Contact Phone: L "¾() J ,S\q _ 4 !>"\ \ Contact Email: Contact information of person completing this checklist (if different than above): Name: Company name/address: Applicant Signature:~cn a.Q ' - B-50 Contact Phone: Contact Email: ,:falca\a&~~w,i@1 ,::o.o(l~\i11-~. (.cry) Date: c,J /z'?/'202( I Page 1 of 6 Revised 08/19 City of Carlsbad Climate Action Plan Consistency Checklist Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For alterations and additions to existing buildings, attach Building Permit Valuation worksheet. Building Permit Valuation (BPV) from worksheet: $ ______ _ Construction Type 8 Residential □ New construction □ Additions and alterations: □ BPV < $60,000 ]& BPV ;e $60,000 □ Electrical service panel upgrade only □ BPV ;e $200,000 0 Nonresidential □ New construction □ Alterations: □ BPV ;e $200,000 or additions ;e 1,000 square feet □ BPV ;e $1,000,000 □ ;e 2,000 sq. ft. new roof addition 1. Energy Efficiency I Complete Sectilll)(I) I Notes: A high-rise residential building is 4 or more stories, including a Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor area is residential use 2A, 3A, 1B, 2B, 4A 3B,4A NIA NIA All residential additions and alterations 1A, 4A 4A 1-2 family dwellings and townhouses with attached garages only 'Multi-family dwellings only where interior finishes are removed 1A, 4A' 1 B, 4A' and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed 18, 2B, 3B, 4B and 5 1B, 5 1B, 2B, 5 Building alterations of ;e 75% existing gross floor area 2B,5 1 B also applies if BPV ;e $200,000 Please refer to Carlsbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CALGreen) for more information when oompleting this section. A .8( Residential addition or alteration ~ $60,000 building permit valuation. See CMC section 18.30.190. Year Built Single-family Requirements Ii' Before 1978 Select one: □ Duct sealino )!I' Attic insulation □ Cool roof □ 1978 and later Select one: □ Lighting package □ Water heating Package □ Between 1978 and 1991 □ 1992 and later □ NIA ---------- □ Exception: Home energy score~ 7 (attach cerlification) Multi-family Requirements □ Attic insulation Select one: □ Duct sealing □ Attic insulation □ Cool roof Select one: □ Lighting package □ Water heating package Nonresidentiar new construction or alterations~ $200,000 building permit valuation, or additions ~ 1,000 square feet □ NIA Updated 8/15/2019 2 City of Carlsbad Climate Action Plan Consistency Checklist See CMC 18.21.155and CALGreen Appendix AS, Division A5.2-Energy Efficiency. A5.203.1.1 Choose one: □ .1 Outdoor lighting □ .2 Warehouse dock seal doors □ .3 Restaurant service water heating (comply "1th California Energy Code section 140.5, as amended) □ N/A _________ _ □ .4 Daylight design PAFs □ .5 Exhaust air heat recovery A5.203.1.2.1 Choose one as applicable: □ .95 Energy budget □ .90 Energy budget □ N/A A5.211.1" □ On-site renewable energy □ N/A A5.211.3" □ Green power (if offered by local utility provider, 50% minimum renewable sources) □ N/A A5.212.1 □ Elevators and escalators □ NIA A5.213.1 □ Steel framing □ N/A • lnciudes hotels/motels and high-rise residential buildings "For alterations~ $1,000,000 BPV and affecting > 75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply with CMC 18.30.130 instead. 2. Photovoltaic Systems A. D Residential new construction (for low-rise residential building permit applications submitted after1/1/20). Refer to 2019 California Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic requirement (2B below) instead. 2) If project includes installation of an electric heat pump water heater pursuant to CMC 18.30.150(9) (high-rise residential) or 18.30.170(9) (low-rise residential), increase system size by .3kWdc if PV offset option is selected. Floor Plan ID (use additional CFA #d.u. Calculated kWdc' sheets if necessary) Total System Size: kWdc = (CFAx.572) / 1,000 + (1.15 x #d.u.) 'Formula calculation where CFA = conditional floor area, #du = number of dwellings per plan type If proposed system size is less than calculated size, please explain. Exception □ □ □ □ kWdc B. 0 Nonresidential new construction or alterations ~$1,000,000 BPV and affecting ~75% existing floor area, or addition that increases roof . , 1 1,,_ area by ~2,000 square feel Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to l"" -r high-rise residential and hoteUmotel buildings. ----'-----------_:_ _____________________ _ Choose one of the following methods: □ Gross Floor Area (GFA) Metihod GFA: □ If< 1 O,OOOs.f. Enter: 5 kWdc Min. System Size: □ If .e 1 O,OOOs.f. calculate: 15 kWdc x (GFA/10,000) .. kWdc .. Round building size factor to nearest tenth, and round system size to nearest whole number. □ Time-Dependent Valuation Metihod Updated 8/15/2019 3 City of Carlsbad Climate Action Plan Consistency Checklist Annual TDV Energy use:'.. ______ x .80= Min. system size: ____ _ kWdc ... Attach calculation documentation using modeling software approved by the California Energy Commission. 3. Water Heating A. D Residential and hotel/motel new construction ;;I}. Please refer to CMC sections 18.30.150 and 18.30.170 when completing this section. □ For systems serving individual dwelling units choose one: □ Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) □ Heat pump water heater AND PV system .3 kWdc larger than required in CMG section 18.30.130 (high rise residential hotel/motel) or CA Energy Code section 150.1 (c) 14 (low-rise residential) □ Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher □ Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors □ Exception: □ For systems serving multiple dwelling units, install a central water-heating system with all of the following: □ Gas or propane water heating system □ Recirculation system per CMG 18.30.150(8) (high-rise residential, hotel/motel) or CMG 18.30.170(8) (low- rise residential) □ Solar water heating system that is either: □ .20 solar savings fraction □ .15 solar savings fraction, plus drain water heat recovery □ Exception: B. D Nonresidential new construction Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section. □ Water heating system derives at least 40% of its energy from one of the following (attach documentation): □ Solar-thermal □ Photovoltaics □ Recovered energy □ Water heating system is (choose one): □ Heat pump water heater □ Electric resistance water heater(s) □Solar water heating system with .40 solar savings fraction □ Exception: Updated 8/15/20 I 9 4 City of Carlsbad Climate Action Plan Consistency Checklist 4. Electric Vehicle Charging A D Residential New construction and major alterations* Please refer to Carlsbad Ordinance CMC section 18.21.140 when completing this section. □ One and two-family residential dwelling or townhouse with attached garage: □ One EVSE Ready parking space required □ Exception : □ Multi-family residential· □ Exception · Total Parking Spaces EVSE Spaces Proposed Capable I Ready I Installed I I Calculations: Total EVSE spaces= .10 x Total par~ng (rounded up to nearest whole number) EVSE Installed= Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other-Total EVSE spaces -EVSE Installed (EVSE other may be "Capable," "Ready" or "Installed.") I Total I 'Major alterations are: (1) for one and two-famHydwellings and townhouses with attached garages, alterations have a building permtt valuation~ $60,000 or inciude an electrical service panel upgrade; (2) for multifamily dwellings (three units or more 1Mthout attached garages), alterations have a building permit valuation~ $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed. 8 D Nonresidential new construction (includes hotels/motels) □ Exception · Total Parking Spaces EVSE Soaces Proposed Capable I Ready I Installed I Total I I I Calculation· Refer to the table below· Total Number of Parkina Soaces orovided Number of reauired EV Spaces Number of renuired EVSE Installed Soaces □ 0-9 1 1 □ 10-25 2 1 □ 26-50 4 2 □ 51-75 6 3 □ 76-100 9 5 □ 101-150 12 6 □ 151-200 17 9 □ 201 and over 10 oercent of total 50 oercent of Required EV Spaces Updated 8/15/2019 5 City of Carlsbad Climate Action Plan Consistency Checklist 5. D Transportation Demand Management (TOM): Nonresidential ONLY An approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT. City staff will use the table below based on your submitted plans to detem,ine whether or nor your pem,it requires a TOM plan. lfTDM is applicable to your permit, staff will contact the applicant to develop a site-specific TOM plan based on the pem,it details. Acknowledgment: Employee ADT Estimation for Various Commercial Uses Office ( all )2 20 Restaurant 11 Retail, 8 Industrial 4 Manufacturing 4 Warehousin 4 1 Unless otherwise noted, rates estimated from /TE Trip Generation Manual, 10'"Edition 13 11 4.5 3.5 3 1 2 For all office uses, use SAN DAG rate of 20 ADT/1,000 sf to calculate employee ADT , Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration Sample calculations: Office: 20,450 sf 1. 20,450 sf/ 1000 x 20 = 409 Employee ADT Retail: 9,334 sf 1. First 1,000 sf = B ADT 2. 9,334 sf -1,000 sf= 8,334 sf 3. 8,334 sf/ 1,000 x 4.5 + 8 = 46 Em lo ee ADT I acknowledge that the plans submitted may be subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should my pem,it require a TOM plan and understand that an approved TOM plan is a condition of pem,it issuance. Applicant Signature: _________________ _ Date: ______ _ Person other than Applicant to be contacted for TOM compliance (if applicable): Name(Printed): __________________ _ Phone Number. _____ _ Email Address: __________________ _ Updated 8/15/2019 6 • Carlsbad Climate Action Plan Trigger Sheet Plan Check Number: CR~~ 2o2o-?33C/ Valuationd!S l "'1gs- 1. Does this project have an electric panel upgrade: Yes EJ Triggers: • New residential (1-2 family dwellings and townhouses with attached garages): If the plans show an electric panel upgrade they need to show details for 1 "EV Ready" EV charging system. o Panel capability, dedicated branch circuit, minimum 40A 2-pole breaker, 1" raceway, No. 8 conductors and receptacle installed to the anticipated charger location. 2. Is EV charging Applicable: es}>o Triggers: • Newly constructed SF residential building: Plans need to show details for 1 "EV Ready" charging system for each unit. o Panel capacity, dedicated branch circuit, minimum 40A 2-pole breaker, 1" raceway, No. 8 conductors and receptacle installed to the anticipated charger location. F residential addition and or alteration: With valuation of $60,000 or more DR an electric panel upgrade need to show details for 1 "EV Ready" charging system. o Panel capacity, dedicated branch circuit, minimum 40A 2-pole breaker, 1" raceway, No. 8 conductors and receptacle installed to the anticipated charger location. • Newly constructed multi-family building: (more than 2 dwelling units). Plans need to show 10% of parking to be EV spaces and 50% (of the 10% EV spaces) to be "EV Installed" spaces. The remaining 50% may be "Capable, Ready, or Installed". o Accessible EV installed spaces per CBC 11B-Table 228.3.2.1. o Single space must be a van accessible EV installed space (if it is a common area parking stall). o Refer to CMC 18.21.140 for stall dimension updates made to 4.106.4.2.2. • Multi-family additions and major alterations: With valuation of;, $60,000 AND including: removal of interior finishes; significant upgrade to structural and mechanical, electrical and/or plumbing systems; and significant site work requiring a grading permit. Plans need to show 10% of parking to be EV spaces and 50% (of the 10%) installed spaces. The remaining 50% may be "Capable, Ready, or Installed". o Accessible EV installed spaces per CBC 11B-Table 228.3.2.1. o Single space must be a van accessible EV installed space (if it is a common area parking stall). o Refer to CMC 18.21.140 for stall dimension updates made to 4.106.4.2.2. • Newly constructed Hotels/ Motel: EV parking per CMC updated Green Code Table 4.106.4.3.1. (10% EV spaces and 50% (of the 10% EV spaces) to be "EV Installed" spaces. • Newly constructed commercial and industrial buildings: Plans need to show 10% of parking to be EV spaces and 50% (of the 10%) to be "EV Installed" spaces. The remaining 50% may be "Capable, Ready, or Installed". o Accessible EV installed spaces per CBC 11B-Table 228.3.2.1. o Single space must be van accessible EV installed space. 3. Was an EV Hardship/ Exemption Approved: Ye~ o See Carlsbad Municipal Code section~l.140 (CGBSC section 4.106.4 exception 4). 4. Provide the applicable EV parking stall count below: • EV Total Spaces: -L • Number of EV Capable: 0 _ • Number of EV Ready: ... -__ / ___ (single family new constn~ctlon, additions and alterations) • l~u,·nber of EV lnsta-:led: D~-(mu.ltl-tamily and comrnercia new construction) 5. Energy Efficiency Applicable: 'CJ No Triggers: c,,Yngle Family AND Multi-Family additions and alterations with valuation of $60,000 or more. CMClS.30.190 • Newly constructed Commercial and Industrial buildings. CMC18.21.155 • New hotels/motels and high-rise residential construction. • Commercial alteration with valuation of $200,000 or more. o If valuation of $1,000,000 or more AND affecting 75% or more of existing floor area or addition of 2,000sf of new roof area see CMC 18.30.130 for solar tradeoff. • Commercial addition of 1,000sf or more. 6. Photovoltaic System Applicable: Yes / 6) PV Size in KW DC Triggers: • Newly constructed low-rise residential buildings. (CEC section 150.1 (c)14). • Newly constructed high-rise residential and hotel/motel buildings are subject to the non-residential PV requirements for new commercial buildings. • o Projects with an electric heat pump shall increase the PV system size by .3kWdc if PV offset option is selected. • Newly constructed commercial and industrial buildings. • Commercial alteration with valuation of $1,000,000 or more AND affecting 75% or more of existing floor area see CMC 18.30.130. • Commercial addition that increases the roof area by 2,000sf or more. 7. Water Heating Applicable: Triggers: • New Single and Multi-Family residential construction. • Newly constructed Commercial and Industrial buildings. Choose between 3 options. (CMC 18.30.150) 8. Transportation Demand Management: Esgil is not responsible for reviewing TOM. Plan Reviewer: ________________ _ Date: __________ _ '(city of Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of permtts are not required to fill out this form ❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool .,. If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. .,. Details on CAP ordinance requirements are available on the city's website . .,. A CAP Building Plan template (form 8-55) shall be added to the title page all building plans. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and download the latest form. Project Name/Building Permit No.: Property Address/APN: 2643 GALICIA WY Applicant Name/Co.: TERRY MONTELLO Applicant Address: 4715 60THS ST Contact Phone: 619-994-5557 BP No. CBR2020-3334 Contact Email: PERMITS@PERMITSINMOTION.COM Contact information of person completing this checklist (if different than above): Name: Company name/address: Contact Phone: Contact Email: Applicant Signature: _______________ Date: _______ _ 8-50 Page 1 of6 Revised 06/18 City of Carlsbad Climate Action Plan Consistency Checklist Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For alterations and additions to existing buildings, attach Building Permit Valuation worksheet. Building Permit Valuation (BPV) from worksheet: $87,475 ------ D Residential □ New construction ~ Additions and alterations: □ BPV < $60,000 ~ BPV;, $60,000 □ Electrical service panel upgrade only □ BPV" $200,000 D Nonresidential □ New construction □ Alterations: □ BPV" $200,000 or additions" 1,000 square feet □ BPV;, $1,000,000 □ "2,000 sq. ft. new roof addition Low-rise N/A 1A,4A 1A, 4A' A high-Ilse residential buik!ing is 4 or more stories, including a High-rise mixed-use building in which at least 20% of its conditioned floor area is residential use 3B,4A I1B, 2B, N/A All residential additions and alterations 4A 1-2 family dwellings and townhouses with attached garages only 'Multi-family dwellings only where interior finishes are removed 1 B, 4A' and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed 1 B, 2B, 3B, 4B and 5 1B, 5 1B, 2B, 5 Building alterations of" 75% existing gross floor area 2B, 5 1 B also applies if BPV" $200,000 Please refer to Carlsbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CALGreen) for more information when completing this section. A. ~ Residential addition or alteration~ $60,000 building permit valuation. See CMC section 18.30.190. Year Built Single4amily Requirements l!I Before 1978 Select one: Cl Duct sealing I] Attic insulation Cl Cool roof □ 1978 and later Select one: Cl Lighting package Cl Water heating Package □ Between 1978 and 1991 □ 1992 and later □ N/A ________ _ □ Exception: Home energy score" 7 (attach certification) Multi4amily Requirements □ Attic insulation Select one: □Duct sealing CIAttic insulation □Cool roof Select one: □ Lighting package □Water heating package B. 0 Nonresidential' new construction or alterations~ $200,000 building permit valuation, or additions ~ 1,000 square feet. □ NIA Updated 8/\5/2019 2 City of Carlsbad Climate Action Plan Consistency Checklist See CMC 1821.155 and CALGreen Appendix AS, Division A52 -Energy Efficiency. AS.203.1.1 Choose one: I] .1 Outdoor lighting [1.2 Warehouse dock seal doors □ .3 Restaurant service water heating (comply with California Energy Code section 140.5, as amended) □ N/A ________ _ a .4 Daylight design PAFs a .5 Exhaust air heat recovery AS.203.1.2.1 Choose one as applicable: 095 Energy budget □.90 Energy budget □ N/A AS.211.1" □ On-site renewable energy □ N/A AS.211.3" □ Green power (if offered by local utility provider, 50% minimum renewable sources) □ N/A AS.212.1 □ Elevators and escalators □ N/A AS.213.1 □ Steel framing □ N/A • Includes hotels/motels and high-rise residential buildings .. For alterations;, $1,000,000 BPV and affecting > 75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply with CMC 18.30.130 instead. 2. Photovoltaic Systems A. 0 Residential new construction (for low-rise residential building permit applications submitted after 1/1/20). Refer to 2019 California Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic requirement (2B below) instead, 2) If project includes installation of an electric heat pump water heater pursuant to CMC 18.30.150(8) (high-rise residential) or 18.30.170(8) (low-rise residential), increase system size by .3kWdc if PV offset option is selected. Floor Plan ID (use additional CFA #d.u. Calculated kWdc' sheets if necessary) Total System Size: kWdc = (CFAx.572) / 1,000 + (1.15 x #d.u.) 'Formula calculation where CFA = conditional floor area, #du = number of dwellings per plan type If proposed system size is less than calculated size, please explain. Exception □ □ □ □ kWdc 8. D Nonresidential new construction or alterations ~$1,000,000 8PV and affecting ~75% existing floor area, or addition that increases roof area by ~.000 square feet. Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to high-rise residential and hotel/motel buildings. Choose one of the following methods: □ Gross Floor Area (GFA) Method GFA: OIi < 10,000s.f. Enter: 5 kWdc Min. System Size: □If;, 1 O,OOOs.f. calculate: 15 kWdc x (GFN10,000) " kWdc "Round building size factor to nearest tenth, and round system size to nearest whole number. □ Time-Dependent Valuation Method Updated 8/15/20 I 9 3 City of Carlsbad Climate Action Plan Consistency Checklist Annual TDV Energy use:**' ______ x .80= Min. system size: _____ kWdc "'Attach calculation documentation using modeling software approved by the California Energy Commission. 3. Water Healing A. 0 Residential and hotel/motel new construction Please refer to CMC sections 18.30.150 and 18.30.170 when completing this section. D For systems serving individual dwelling units choose one: D Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) D Heat pump water heater AND PV system .3 kWdc larger than required in CMC section 18.30.130 (high rise residential hotel/motel) or CA Energy Code section 150.1 (c) 14 (low-rise residential) D Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher D Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors D Exception: D For systems serving multiple dwelling units, install a central water-heating system with all of the following: D Gas or propane water heating system □Recirculation system per CMC 18.30.150(8) (high-rise residential, hotel/motel) or CMC 18.30.170(8) (low- rise residential) D Solar water healing system that is either: □ .20 solar savings fraction □ .15 solar savings fraction, plus drain water heat recovery D Exception: B. 0 Nonresidential new construction Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section. D Water healing system derives at least 40% of its energy from one of the following (attach documentation): D Solar-thermal □ Photovoltaics D Recovered energy □Water heating system is (choose one): Cl Heat pump water heater □ Electric resistance water heater(s) □Solar water heating system with .40 solar savings fraction D Exception: Updated 8/15/2019 4 City of Carlsbad Climate Action Plan Consistency Checklist ~---~-"----------------------------------------4. Electric Vehicle Charging A [!] Residential New construction and major alterations* Please refer to Carlsbad Ordinance CMC section 18.21.140 when completing this section. ~ One and two-family residential dwelling or townhouse with attached garage: [!] One EVSE Ready parking space required D Exception : D Multi family residential· D Exception · - Total Parking Spaces EVSE Spaces Proposed Capable Ready Installed Calculations: Total EVSE spaces= .10 x Total parking (rounded up to nearest whole number) EVSE Installed= Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other= Total EVSE spaces-EVSE Installed (EVSE other may be "Capable," "Ready" or "Installed.") Total 'Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation ~ $60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), alterations have a building permit valuation ~ $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed. B D Nonresidential new construction (includes hotels/motels) D Exception · Total Parking Spaces EVSE Spaces Proposed Capable Ready I Installed I Total I I Calculation· Refer to the table below· Total Number of Parkin□ Spaces orovided Number of recuired EV Spaces Number of reauired EVSE Installed Soaces □ 0-9 1 1 □ 10-25 2 1 □ 26-50 4 2 □ 51-75 6 3 □ 76-100 9 5 □ 101-150 12 6 □ 151-200 17 9 n 201 and over 10 percent of total 50 percent of Required EV Spaces Upclatccl 8/15/20 I 9 5