Loading...
HomeMy WebLinkAbout1923 CALLE BARCELONA; 147; AS050021; Permit6/16/22, 3:48 PM AS050021 Permit Data City of Carlsbad Sprinkler Permit Job Address: 1923 CALLE BARCELONA Permit Type: SPRINK Parcel No: 2550120400 Lot#: 0 Reference No.: Permit No: AS050021 Status: ISSUED Applied 2/24/2005 Approved: 2/25/2005 Issued: 2/25/2005 PC #: Inspector: Project Title: POUT A CHILD'S BOUTIQUE FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: BRADSHAW ENGINEERING CORP 8645 ARGENT ST SANTEE CA 619-448-4300 Fees($) Add'I Fees ($) 115 0 Owner: BORDERS INC FOURTH QUARTER PROPERTIES XXX L C/ BORDERS INC 300 VILLAGE GREEN CIR SE #200 SMYRNA GA Total($) Balance($) 115 0 1 /1 Reliabld Product Description The Reliable Model G Automatic Sprinkler utilizes the center strut solder in compression principle of construction. The fusible alloy is captured in the cylinder of the solder capsule by a stainless steel ball. When the fusible alloy melts, the ball moves into the cylinder allowing the cylinder to fall away from the sprinkler. When this happens, the lever is released to spring free from the sprinkler so that all of the operating parts clear from the waterway allowing the deflector to distribute the discharging water. Except for the parts in the cylinder as mentioned above, the sprinkler components are made from copper based alloys for maximum corrosion protection. Lead plated, wax coated or wax over lead plated sprinklers are available for specially severe environments. Chrome plated sprinklers are available for decorative purposes. All sprinklers are individually hydrostatically tested. All sprinklers are identified as to their fusing point by markings that appear on several of the operating parts and by an identifying color that appears on the frame. Sprinkler Types Standard Upright -This deflector configuration is normally used with exposed piping installations. Water is distributed laterally and downward in a wide pattern approximating a hemisphere which is completely and uniformly filled with water in the form of small drops or spray. At a sprinkler height of 10 feet (3m), a circular area of approximately 20 feet (6.1 m) in diameter is covered by the water discharged at the minimum pressure. Standard Pendent -This deflector configuration is normally used where the space above the piping is not adequate or where a concealed piping installation is employed. The discharge characteristics of the standard pendent are virtually identical to the standard upright as described above. Large and Small Orifice-By varying the orifice size, a large or small orifice sprinkler is created that will distribute as much as 40% more water or 65% less water than the normal ½" (15mm) orifice sprinkler. These sprinklers are identified by the orifice size that is stamped in the base of the sprinkler and by the pintle that extends from the deflector-the exception is the large orifice sprinkler with the¾" NPT (R¾) inlet thread where the size of the inlet is sufficient to classify this sprinkler as one having a larger than standard orifice. Model G Automatic Sprinklers Spray Upright, Spray Pendent And Conventional A..sos-0021 Upright Pendent Small Orifice Upright Conventional Conventional-This deflector configuration is used pri- marily in those countries where the LPC installation rules have precedence. The sprinkler is designed to distribute a portion of its water discharge upward against the ceil- ing with the balance downward. It may be installed in ei- ther the upright or the pendent position. Sprinklers with conventional deflectors are available with orifice sizes corresponding to light, ordinary and extra-high hazard installations. Application and Installation Standard sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice sizes, temperature ratings, deflector styles and sprinkler spacings are in accordance with the latest published stan- dards of the National Fire Protection Association or the approv- ing authority having jurisdiction. The sprinklers must be installed with the Reliable Model D Sprinkler Wrench. Any other type of wrench may damage the sprinkler. The approvals or listings of Reliable Automatic Sprinklers by major approving organizations are shown in the tabulated list provided on the back of this bulletin. *Patent No. 4,440,234 The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 -.I. -.I. 0 ::0 (D ~ ::0 Technical Data "K" Factor Sprinkler Type us Standard-Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position X." (15 mm) Standard Orifice with X." NPT (RX.) Thread 5.62 Y,6" (11 mm) Small Orifice with X." NPT (RX.) Thread 4.24 ¾" (10 mm) Small Orifice with X." NPT (RX.) Thread 2.82 Y,6" (8 mm) Small Orifice with X." NPT (RX.) Thread 1.98 %" (20 mm) Large Orifice with X." NPT (RX.) Thread 7.96 1½t (20 mm) Large Orifice with ¾" NPT (R¾)Thread 8.20 20 mm XHH with 20 mm Thread 8.20 10 mm XLH with 10 mm Thread 4.10 Conventional-Installed in UpriQht or Pendent Position 10mm XLH with 10mm Thread 4.10 15mm Standard Orifice with (RX.) Thread 5.62 20mm XHH with (R¾) Thread 8.20 T emperature Rf a 1ngs Maximum Sprinkler Ambient Rating Temperature Frame (1> Classification OF oc OF oc Color Ordinary 135 57 100 38 Black Ordinary 165 74 100 38 Uncolored Intermediate 212 100 150 66 White High 286 141 225 107 Blue (1) Frame color does not apply to painted or plated sprinklers-Use sprinkler rating as identified on operating parts. Finishes(1> Standard Finishes Bronze -All Temperature Ratings Chro~~ -All Temperature Ratings White l -All Temperature Ratings Only Frame and Deflector are Painted Special Application Finishes Metric 81 .0 61 .0 40.6 28.5 114.7 118.2 118.2 59.1 59.1 81 .0 118.2 Sprinkler Identification Sprinkler Number (SIN) Height Approvals ssu SSP 2 ½" (73mm) 1,2,3,4,5,6, 7 R1025 R1015 2 ½" (73mm) 1, 3, 7 R1023 R1013 2 ½" (73mm) 1, 2, 3, 7 R1021 R1011 2 ½" (73mm) 1, 3, 7 R1022 R1012 2½" (73mm) 1, 2, 3, 7 R1026 R1016 2 %" (75mm) 1, 2, 3, 7 R1027 R1017 75.4 mm 4,5,6 R1027 R1017 73mm 4,5,6 R1024 R1014 73mm 5 R1074 73mm 4,5,6 R1075 75.4 mm 4,5 R1077 Maintenance Model G Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove any sprinkler that has been painted ( other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Use only the Model D Sprinkler Wrench for sprinkler removal and installation. Any other type of wrench may damage the sprinkler. Approval Organizations 1. Underwriters Laboratories, Inc. 2. Factory Mutual Research Corporation 3. Underwriters' Laboratories of Canada 4. Loss Prevention Council 5. Pleniere Assemblee 6. Verband der Schadenversicherer eV Bright Brass Plated -Only frame, deflector and cap are plated. 135°F (57°C), 165°F 7. N.Y.C. BS&A No. 587-75-SA (74°C), 212°F (100°C) Temp. Rating. Black Plated -Only frame, deflector and cap are plated. All Temp. Ratings. Polyester Coated (2) -Only frame and deflector are coated. Lead Plated -165°F (74°C), 212°F (100°C) and 286°F (141 °C) Temp. Ratings. Wax-Coated (3) -165°F (74°C) Clear Wax, 212°F (100°C) Brown Wax. Wax-Coated Over Lead Plated (3) -165°F (74°C) Clear Wax, 212°F (100°C) Brown Wax. (1) Other colors and finishes are available. Consult factory for details. (2) UL listed and NYC MEA Approved only. {3) 212°F (100°C) brown wax may be used on 286°F (141 °C) sprinklers when maximum ambient temperatures do not exceed 150°F (66°C). UL Listed, FM Approved, NYC MEA 258-93-E. 8. N.Y.C. MEA 258-93-E Ordering Information Specify 1. Model G 2. Deflector • Upright • Pendent • Conventional 3. Nominal Orifice 4. Inlet Thread 5. Temperature Rating 6. Finish The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. Reliable1 (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 668-3470 Corporate Offices ~ R8()'tled ~ Paper Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 4/03 PIN 999997CXX)5 Reliabld The Concealer® A Concealed Sprinkler With½" (13mm) or 1½" (38mm) Adjustment Features 1. Push-on{fhread-off cover plate assembly attachment with ½" (13mm) adjustment. Does not require clips or springs. 2. 1½" (38mm) Total adjustment provided by adjustable inlet versions. 3. Adjustable inlet version available with either 1" NPT ale or female threads eliminating costly reducing coupling. 4. Smooth aesthetic ceiling profile. 5. Available in white or other color painted or brass, chrome, or black plated finishes. 6. Ordinary and intermediate temperature ratings. 7. Multiple orifices for design flexibility. Approvals & Listings 1. Underwriters Laboratories Inc. (UL) 2. Underwriters Laboratories of Canada. (ULC) 3. N.Y.C. BS&A No. 587-75-SA. Note: Approvals are for light and ordinary hazard, except for small orifice sprinklers which are limited to light hazard occupancies. The cup and skirt are fabricated from plated steel and are intended for interior non corrosive applications. U.S. Patent No. 4,880,063. Application The Reliable Model G4 Concealer® is the most versatile concealed sprinkler available. It provides the best form of fire pro- tection while offering an attractive appearance and ½" ( 13mm) of cover adjustment for ease of instal- lation. The adjustable 1" NPT inlet versions have 1 ½" (38mm) of total adjustment and also eliminates the need for a reducing cou- pling. The small diameter Push-on/Thread-off cover plate assembly is easily attached and blends into the ceiling, con- cealing the most dependable fire protection available, an automatic sprinkler system. Bulletin 121 Rev.I Model G4 Concealed Automatic Sprinkler The Concealer® is designed for use where aesthetic ap- pearance is important. Offices, hospitals, motels and res- taurants are but a few of the applications where it can be used. It is available in different orifice sizes allowing the de- signer to optimize system performance, thereby achieving a most efficient installation. The Concealer® can eliminate the need for precise cutting of drop nipples. The Push-on/Thread-off cover plate assem- bly can be adjusted without tools so it mates accurately with the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. Product Description The Reliable Model G4 Concealer® uses the proven Model G fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate. The Push-on/Thread-off cover plate and sprinkler cup assem- blies are held tight by a flexible tooth engagement to the threaded cup. This threaded engagement provides ½" ( 13mm) of cover adjustment. The flat cover plate is attached to the skirt using an ordinary temperature classification sol- der. This results in a strong cover plate assembly with an or- dinary temperature rating, and an intermediate temperature sprinkler which can be installed in 150°F (66°C) environ- ments. When the ceiling temperature rises, the solder hold- ing the cover plate to the skirt melts, the flat cover plate released thus exposing the sprinkler inside to the rising am- bient temperature. The subsequent fusing of the sprinkler element opens the waterway and causes the deflector to drop into position to distribute the discharging water. Any secure engagement of the threads between the cover plate and cup will assure that the drop-down deflector is properly located below the ceil- ing when a sprinkler operates. The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 OJ C ro ~-::J .....I. I\.) .....I. :0 CD ~ Installation Do not install The Concealer® in ceilings which have positive pressure in the space in the space above. After a 2'5/4 inch diameter hole is cut in the ceiling, the sprinkler is to be installed with the Model G4 Wrench. The wrench has drive tangs which insert into cup slots. When installing a sprin- kle~ the wrench is first positioned into the sprinkler/cup assembly until the wrench tangs engage drive slots in the top of the cup (there are two sets of mating drive slots in the cup). The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/cup assembly care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY. The adjustable inlet versions are similar to the standard Model G4 except that an addition 1" (25mm) of adjustment is provided by means of a telescoping inlet section that threads in or out of a stationary coupling reducer ( either 1 male or 1 female) as shown in Fig. 2 or Fig. 3. These sprinklers must be installed before the ceiling is in place, by wrenching on only the coupling reducer Temperature Ratings Classification Sprinkler Cover Plate Max. Ambient Temp. Ordinary 135°F/57°C 135°F/57°C 100°F/38°C Ordinary 165°F/74°C 135°F/57°C 100°F/38°C Ordinary 165°F/74°C 165°F/74°C 100°F/38°C Intermediate 212°F/100°C 165°F/74°C 150°F/66°C Installation Data Nominal Sprinkler Total Nominal K 1:.,.,.+,-.r Thread Inlet Adjustment Orifice us Metric f\Jon--Adjustable X '(13mm) ½_"(15mm) 5.6 80 X''NPT(R½) Non-Adjustable X"(13mm) 1/,/(11mm) 4.2 00 );;"NPT(R½) f\Jon--Adjustable X"(13mm) ¾"(1Cmm) 2.8 40 );;"NPT(R½) hex flats. After the ceiling has been installed with holes for the sprinkler, each telescoping inlet section is to be adjusted with the G4 Wrench. Install the push-on/thread-off cover plate assembly over the sprinkler by holding and pressing it straight up into the cup. Final adjustment of each cover assembly is made by hand turning it clockwise until it is tight against the ceiling. Maintenance The Model G4 Concealer® should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any ot~er cleaning fluids. Remove any sprinkler that has been painted (other tha_n factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick re- placement of damaged or operated sprinklers. Prior to installa- tion, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Ordering Information 1. Sprinkler Model 2. Temperature Rating 3. Nominal Orifice 4. Flat Cover Plate Finish 5. Inlet Type Note: Unless otherwise specified, the 165°F (74°C) sprinkler will be provided with the 165°F (74°C) cover. Sprinkler Identification Approvals Number fCIM\ 1,2,3 R2115 1,2,3 R2113 1,2,3 R2111 Cover Plate Finishes (1> Standard Finishes Bronze Chrome Plated White Special Application Finishes Black Plated Bright Brass Off White Black Paint (1) Other colors and finishes are available. Consult factory for details Adjustable 1);;''(38mm) ½_"(15mm) 5.6 80 1" NPT Male or Female 1,2,3 R2118 Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. Adjustable 1);;''(38mm) 1/,6"(11mm) 4.2 Adjustable 1)t (38mm) ¾"(1Cmm) 2.8 Fig. 1 -½" (R½) NPT Non-Adjustable Inlet 00 1" NPT Male or Female 1,2,3 40 1" NPT Male or Female 1,2,3 Fig. 2 -1" NPT Male-Adjustable Inlet R2113 R2112 Installation Wrench Model G4 Sprinkler Wrench Fig. 3 -1" NPT Female-Adjustable Inlet The equipment presented i~ this bulletin i~ tC? be install_ed \n accordance "".'ith the lates_t pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other s1m1lar organizations and also with the provIsIons of governmental codes or ordinances whenever applicable. Prod.~cts manufactured an~ distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qual1f1ed and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliabl~ The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Office (800) 848-6051 Sales Fax (914) 668-3470 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 06/02 P/N 9999970014