Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2540 FARADAY AVE; ; CBC2019-0530; Permit
PERMIT REPORT Commercial Permit Print Date: 05/24/2022 Job Address: 2540 FARADAY AVE, CARLSBAD, CA 92008 Permit Type: BLDG-Commercial Work Class: New Parcel#: 2091200100 Track#: Valuation: $7,065,241.05 Lot#: Occupancy Group: Project#: DEV2017-0042 #of Dwelling Units: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Project Title: OAKMONT OF CARLSBAD (city of Carlsbad Permit No: CBC2019-0530 Status: Closed -Finaled Applied: 11/14/2019 Issued: 12/23/2020 Finaled Close Out: 04/05/2022 Inspector: Final Inspection: TAlva 04/05/2022 Description: OAKMONT: 42,749 SF MEMORY CARE BUILDING WITH 6,086 SF PATIO AND 1,040 SF PORTE COCH ERE Property Owner: OAKMONT OF CARLSBAD LLC 2560 FARADAY AVE CARLSBAD, CA 92010 (442) 325-8090 FEE SB1473 GREEN BUILDING STATE STANDARDS FEE SEWER BENEFIT AREA FEES -E TRAFFIC IMPACT Commercial-Industrial w/in CFD SEWER CONNECTION FEE (General Capacity all areas) GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION BUILDING PLAN CHECK FEE (BLDG) ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL STRONG MOTION-COMMERCIAL BUILDING PERMIT FEE ($2000+) FIRE Plan Resub (3rd&Subsequent Submittal/hr) FIRE R-1 & R-2 Occupancies ~50 units New LOCAL FACILITIES MANAGEMENT ZONE (LFMZ)-ZONE 16 COMMUNITY FACILITIES DISTRICT (CFD) FEE -NON-RES PUBLIC FACILITIES FEES -inside CFD SB1473 GREEN BUILDING STATE STANDARDS FEE SEWER BENEFIT AREA FEES -E TRAFFIC IMPACT Commercial-Industrial w/in CFD SEWER CONNECTION FEE (General Capacity all areas) GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION BUILDING PLAN CHECK FEE (BLDG) ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL STRONG MOTION-COMMERCIAL BUILDING PERMIT FEE ($2000+) FIRE Plan Resub (3rd&Subsequent Submittal/hr) FIRE R-1 & R-2 Occupancies ~SO units New LOCAL FACILITIES MANAGEMENT ZONE (LFMZ) -ZONE 16 COMMUNITY FACILITIES DISTRICT (CFD) FEE -NON-RES PUBLIC FACILITIES FEES -inside CFD Total Fees: $750,913.74 Total Payments To Date: $750,913.74 Balance Due: AMOUNT $283.00 $122,958.00 $24,759.00 $32,335.20 $175.00 $10,923.74 $2,523.00 $434.00 $1,978.27 $15,605.34 $476.00 $1,468.00 $17,099.60 $15,851.33 $128,587.39 $283.00 $122,958.00 $24,759.00 $32,335.20 $175.00 $10,923.74 $2,523.00 $434.00 $1,978.27 $15,605.34 $476.00 $1,468.00 $17,099.60 $15,851.33 $128,587.39 $0.00 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov l_ City of Carlsbad COMMERCIAL BUILDING PERMIT APPLICATION 8-2 Plan Check Ci)C,)ojg-{)Sj'.) Est. Value J\J+0(c5, JY l.os PC Deposit ---,-----,--c--cc."""""c---- D ate ll/ill/19 Job Address 2540 Faraday Avenue, Carlsbad _____ Suite: ___ APN: 209-120-01-00 Tenant Name: __ O~a~k_m~o_n_t_o_f C~ar_ls~b_a~d ________ CT/Project#: CUP 2017-0008 Lot#: ---- Occupancy: R2.1, A-2. A-3. B, S-2. U & S1 Construction Type: _V~A~--Fire Sprinklers:@-V no Air Conditioning: ~ no BRIEF DESCRIPTION OF WORK: Constructions~~ of_? Se_i:,_l~r llvina Facilitv ~ Memo-y Care Building on the same site as the Assisted Living Building and the Marketing Building already in process. r [Zi ~ddition/New: 42,749 SQ FT Memo,, CareBu_if<1in2_New S~a-;d u;:·-~040 so EI Porte Cacbere New SF and Use, . __ _ Deck SF, __ 6.086 .. Patio Cover SF (not including flatwork) :=J Tenant Improvement: .. --_______ SF, .... ____ ___ SF, Existing Use Existing Use Proposed Use Proposed Use. □ Pool/Spa: Additional Gas or Electrical Features? _ No~e__ _. _____ _ L'J Solar: ___ KW, __ Modules, ___ . Mounted, Tilt: Yes/ No, RMA: Yes/ No, Panel Upgrade: Yes/ No ::.J Plumbing/Mechanical/Electrical Only: __J Other: APPLICANT (PRIMARY) PROPERTY OWNER Name: Oakmont Senior Living• Grego Wanke, Sr. Proieci Designer Name: -~O~•~k~m=o=nt~o~f=C=•=rls~b=•=d=L=LC~------------ Address: 9240 Old Redwood Hwy, Suite 200 Address: 9240 Old Redwood Hwy, Suite 200 City: Windsor State:~c~A~_Zip: 95492 Phone: 707-535-3234 Email: gregg wanke@oakmontsl com DESIGN PROFESSIONAL Name; B Hills Architecture Address: 3156 s Bown Way City: Boise Phone: 208-258-6154 Email: bhills@bhtllsarch com State: Idaho Zip: ~8~3ZwP~6~-- Architect State License: __ C_-_3_7_12_8 ___ _ City: --~w=,n=ds=o~r ______ State:~c=A~_Z.ip: .95492 __ _ Phone: -~70=7~-5=3~5~-3~2~0~0 _____________ _ Email: ______ _ CONTRACTOR BUSINESS Name: OSL Construction Inc. Address: _ 9240 Old Redwood Hwy. Suite 200 City: Windsor Phone: 707-535-3200 State:_c~A~_.Zip: 95492 Email: David Hunter@oakmontsl.com I David Hunter. Director of Construct1on State License:_8~0~6~36~5~ ___ Bus. License: BLOS005682-05-2019 (Sec 7031.5 Business and Professions Code: Any City or County which require1 a permit to construct, alter, improve, demolish or repair any structure, rmor to its h\u.JncP, also requires the applicant for such perm·1t to file a s·1gned statement that he/~tle i~ lteensrid pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of D1v1sion 3 of the Busmes5 and Profes~wns Code) or that he/she is e)(empt thPcrefrom, and the basis for the alleged Pxen1pt1on. Any v1olatmn ot Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than t1ve hundrC'd dollar~ {$500}). 1635 Faraday Ave Carlsbad, CA 92008 B-2 Ph: 760-602-2719 Fax: 760-602-8558 Page 1 of 2 Email: BuildLrig(!;lc:_arlsbadca.y~ov Rev. 06/18 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury Q[lg_ of the following declarations: "..11 h;we ,mo will maintain a certificate of consent to ~e!f.·1nwr<" for workers compemation prov·rded by Section 3700 of the labor Code, lor the perform<rnce of the work which this permit is issued XI I have and will maintain worker'~ compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit 1s ·1ssued My workers' compensation insurance earner and policy number ;ire: Insurance Company Name: :rra_y~!e[s ~~o_qertJ Cas_~~l!..t_ Qofl").Qany 9_f_~_!!lerica Policy No. U8~8M954,797~ 19-51-K _ Expiration Date: 05101 /2020 :::J Cert1f1cdt£' of Exemption. I certify that 1nthe performance of the work for which this permit is issued, I shall not employ any per.son in any manner so as to be come subject to the workers' compen.sation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to crim'inal Pi,!nalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, ;nte,e,t and attorney', fee,. ..~) /:4' CONTRACTOR SIGNATUREf / ,~~ _____ _JAGENT DATE: November 5. 2019 ~y ( OPTION B ): O1,\/1'/JR-BUILDER [)_ECLJ\RAJIQ_N: I hereby affirm that I am exempt from Contractor's License Law for the following reason: □ I, as ownpr of the property or my employees with wages as their ~ole compenscttion, will do the work and thC' structure is not intended or offered for ~ale (Sec 7044, Busme,s and Professions Code: The Contractors License l·.iw doe'> not apply to an ownt>r of property who builds or Improves then•on, and who does such work h1rnse!f or throwgh his own employees, provided that swch improvements are not intrnded or offered for sale. If, however, th~ building or improvemrnt is sold withm one year ct cornplet1on, the owner-builder will have the burdPn of proving that he did not build or improve for the purpose of salr>) :, I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sf>c. 7044, Business and Professions Code The Contractor's license law does not apply to an owner of property who butlds or improves thereon, and contracts for such projects w·1th contractor(s) JicPnsed pursuant to the Contractor's license Law) :JI am exempt under Section Busine'>:. and Professions Code for this re,Hon: 1 I persona!ly plan to provide the ma;or labor and materials for construction of thl' proposed property improvement '.J Yes O No 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contrdcted with the following person (firm) to provide the propo:,ed construction (include n<1me address/ phone/ contractors' license number)· 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): S. J will provide some of the work, but I have contracted (hired) the following person<. to provide the work ·1nd·1cated (include name/ address/ phone/ type of work): OWNER SIGNATURE: CONSTRUCTION LENDING AGENCY, IF ANY: I hereby a1firm that therr is a constn;ction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: Lender's Address: ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUIWING PERMITS ONLY: Is the applicrrnt or future building occupant required to submit a business plan, acutely halJrdous materials registration form or rhk manarwment and prevC'ntron progr,:im undei Sections 25505, 25533 or 25534 of the Presley-Tanner Halardous Substdnce Account Act? "J Yes □ No Is the applicant or future building occupant required to obtain a permit from the air pollution control d1~trict or air quality management d1stnct J □ Yes ::J NO Is the facility to be constrncted within 1,000 foet of the outer boundary of a school >it('? n Yes □ No IF ANY OF THE ANSWERS ARE YES,A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that! have read the application and state thdt the above informat:on 1s corrrxt ,ind thdt the mformation on the plan.~ 15 accurcite I agrN' to comply wlth all City ordinance, ctnd State lciws relating to building construction. I hereby authorize representative of the City of Carlsbad to entf>r upon the above mf'nt1oncd property for inspection purposes. I ALSO AGREE TO SAVE. INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST All LIABILITIES, JUDGMl::NTS, COS'i5> AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavdtion~ over 5'0' deep and demolition or construction of structwres over 3 •itories m height EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void 1f the building or work author/z('d by such pern11t 1~ not commenced within 180 days trO~i(h<" date of !uch perrfiit or if the building or work authorized by such permit 1~ suspended or ;ibandoned at any timf' after the work is cornmencpd for a pNiod of 180 da·,s 1Sett1dn 1, J.,1 Unifor)n Buildmr, CodC') d j ' ' I APPLICANT SIGNATURE: 1635 Faraday Ave Carlsbad, CA 92008 B-2 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of 2 DATE: _N_ov_e_rn_b_e_r_5_. _2_0_19 __ Email: Building(iilcarlsbadca.gov Rev. 06/18 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Status: Scheduled Date 04/07/2022 Closed -Finaled Actual Inspection Type Start Date Checklist Item BLDG-Plumbing Final BLOG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final BLDG-Electrical Final 04/07/2022 BLDG-Fire Final Checklist Item FIRE-Building Final Tuesday, May 24, 2022 Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Issue Date: 12/23/2020 Expiration Date: 09/27/2022 IVR Number: 23094 Subdivision: Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Inspection No. Inspection Status Primary Inspector Reinspection Inspection COMMENTS April 5, 2022: 1. Final Structural, Electrical, plumbing and mechanical, per structural engineer's plans and details-approved. 2. All ADA title 24 elements/components addressed, and approved. 3. No outstanding correction items remaining-project approved. 4. Fire life safety elements inspected, verified, and approved. April 5, 2022: 1. Final Structural, Electrical, plumbing and mechanical, per structural engineer's plans and details-approved. 2. All ADA title 24 elements/components addressed, and approved. 3. No outstanding correction items remaining-project approved. 4. Fire life safety elements inspected, verified, and approved. April 5, 2022: 1. Final Structural, Electrical, plumbing and mechanical, per structural engineer's plans and details-approved. 2. AH ADA title 24 elements/components addressed, and approved. 3. No outstanding correction items remaining-project approved. 4. Fire life safety elements inspected, verified, and approved. April 5, 2022: 1. Final Structural, Electrical, plumbing and mechanical, per structural engineer's plans and details-approved. 2. All ADA title 24 elements/components addressed, and approved. 3. No outstanding correction items remaining-project approved. 4. Fire life safety elements inspected, verified, and approved. January 25, 2022: Electrical final, Assisted living building, third level floor, recheck dwelling units, ADA restrooms and common areas, sub-panels and GFCI protection outlets -partial pass. 179384-2022 COMMENTS Passed Felix Salcedo Passed Yes Yes Yes Yes Yes Complete Passed Yes Page 50 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Issue Date: 12/23/2020 Subdivision: Status: Scheduled Date 03/31/2022 04/0512022 Closed -Finaled Expiration Date: 09/27/2022 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 IVR Number: Actual Inspection Type Start Date Inspection No. Inspection Primary Inspector Status 03/3112022 BLDG-34 Rough Electrical 179420-2022 Partial Pass Tony Alvarado Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS March 31, 2022: 1. Rough electrical, emergency lighting, memory care building, Partial pass. 2. egress exit signs-illuminated and wall signs -partial pass. August 11, 2021. 1. Switchgear room, for memory care building, footings and UFER ground wire bonded and approved. 04/05/2022 BLDG-Final Inspection 179779-2022 Passed Tony Alvarado Reinspection Inspection Reinspection Incomplete Passed Yes Yes Complete Tuesday, May 24, 2022 Page 49 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Status: Scheduled Dale 01/26/2022 02/18/2022 Closed -Finaled Actual Inspection Type Start Date Checklist Item BLOG-Electrical Final BLDG-Electrical Final BLDG-Electrical Final 01/2612022 BLDG-Final Inspection Checklist Item BLDG-Electrical Final BLDG-Electrical Final BLDG-Electrical Final 02/18/2022 BLDG-Final Inspection Checklist Item BLOG-Electrical Final BLOG-Electrical Final BLDG-Electrical Final Tuesday, May 24, 2022 Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Issue Date: 12/23/2020 Subdivision: Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Inspection No. COMMENTS Inspection Status January 25, 2022: Primary Inspector Electrical final, Assisted living burlding, third level floor, recheck dwelling units, ADA restrooms and common areas, sub-panels and GFCI protection outlets -partial pass. January 21, 2022: Electrical final walk-through recheck for dwelling units sub-panels and GFCI protection outlets -partial pass. January 24, 2022: Electrical final, Assisted living building, second level, recheck dwelling units, ADA restrooms and common areas, sub-panels and GFCI protection outlets -partial pass. 175380-2022 COMMENTS Passed January 20, 2022: Tony Alvarado 1. Electrical GFCl's and sub panel dwelling unit and common area final inspection recheck. 2. Assisted living building, first floor level areas only-partial pass. January 26, 2022: Electrical final, Assisted living building, third level, recheck dwelling units, ADA restrooms and common areas, sub-panels and GFCI protection outlets -Approved. January 24, 2022: Electrical final, Assisted living building, second level, recheck dwelling units, ADA restrooms and common areas, sub-panels and GFCI protection outlets -partial pass. 176983-2022 COMMENTS Partial Pass Tony Alvarado January 25, 2022: Electrical final, Assisted living building, third level floor, recheck dwelling units, ADA restrooms and common areas, sub-panels and GFCI protection outlets -partial pass. January 24, 2022: Electrical final, Assisted living building, second level, recheck dwelling units, ADA restrooms and common areas, sub-panels and GFCI protection outlets -partial pass. February 18, 2021: memory care building. 1. Reinspect Partial areas and floors, final electrical GFCl's outlets-approved. Reinspection Inspection Passed Yes Yes Yes Complete Passed Yes Yes Yes Reinspection Incomplete Passed Yes Yes Yes Page 48 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530} Permit Type: BLDG-Commercial Work Class: New Status: Scheduled Date 01/24/2022 01/25/2022 Closed -Finaled Actual Inspection Type Start Date Checklist Item BLOG-Plumbing Final BLDG-Structural Final BLDG-Electrical Final 01/24/2022 BLDG-Final Inspection Checklist Item BLDG-Electrical Final BLDG-Electrical Final Checklist Item BLDG-Electrical Final BLDG-Electrical Final 01/25/2022 BLDG-Final Inspection Tuesday, May 24, 2022 Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Issue Date: 12/23/2020 Subdivision: Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Inspection No. COMMENTS Inspection Status January 11, 2022: Primary Inspector 1. Final walk-through, first floor locations memory care building, dwelling units (only) -partial pass. January 11, 2022: 1. Final walk-through, first floor locations memory care building, dwelling units (only) -partial pass. January 21, 2022: Electrical final walk-through recheck for dwelling units sub-panels and GFCI protection outlets -partial pass. 175171-2022 COMMENTS Partial Pass Tony Alvarado January 24, 2022: Electrical final, Assisted living building, second level, recheck dwelling units, ADA restrooms and common areas, sub-panels and GFCI protection outlets -partial pass. January 21, 2022: Electrical final walk-through recheck for dwelling units sub-panels and GFCI protection outlets -partial pass. COMMENTS January 24, 2022: Electrical final, Assisted living building, second level, recheck dwelling units, ADA restrooms and common areas, sub-panels and GFCI protection outlets -partial pass. January 20, 2022: 1. Electrical GFCl's and sub panel dwelling unit and common area final inspection recheck. 2. Assisted living building, first floor level areas only-partial pass. 175234-2022 Partial Pass Tony Alvarado Reinspection Inspection Passed Yes Yes Yes Reinspection Incomplete Passed Yes Yes Passed Yes Yes Reinspection Incomplete Page 47 of 50 PERMIT INSPECTION HISTORY for {CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Status: Scheduled Date 01/20/2022 01/21/2022 Closed -Finaled Actual Inspection Type Start Date Checklist Item BLDG-Plumbing Final BLOG-Mechanical Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final 01/20/2022 BLDG-Final Inspection Checklist Item BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Electrical Final 01/21/2022 BLDG-Final Inspection Tuesday, May 24, 2022 Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Issue Date: 12/23/2020 Subdivision: Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Inspection No. COMMENTS Inspection Status January 19, 2022: Primary Inspector 1. Dwelling units and ADA restrooms - partial pass. 2. Pending outstanding AC units and miscellaneous room items. 3. Rest of work -OK. January 19, 2022: 1. Dwelling units and ADA restrooms - partial pass. 2. Pending outstanding AC units and miscellaneous room items. 3. Rest of work -OK. January 11, 2022: 1. Final walk-through, first floor locations memory care building, dwelling units (only) -partial pass. January 19, 2022: 1. Dwelling units and ADA restrooms - partial pass. 2. Pending outstanding AC units and miscellaneous room items. 3. Rest of work -OK. January 19, 2022: 1. Dwelling units and ADA restrooms - partial pass. 2. Pending outstanding AC units and miscellaneous room items. 3. Rest of work -OK 174952-2022 COMMENTS Partial Pass Tony Alvarado January 19, 2022: 1. Dwelling units and ADA restrooms - partial pass. 2. Pending outstanding AC units and miscellaneous room items. 3. Rest of work -OK. January 11, 2022: 1. Final walk-through, first floor locations memory care building, dwelling units (only) -partial pass. January 20, 2022: 1. Electrical GFCl's and sub panel dwelling unit and common area final inspection recheck. 2. Assisted living building, first floor level areas only-partial pass. 175132-2022 Partial Pass Tony Alvarado Reinspection Inspection Passed Yes Yes Yes Yes Yes Reinspection Incomplete Passed Yes Yes Yes Reinspection Incomplete Page 46 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Status: Scheduled Date 01/1912022 Closed -Finaled Actual Inspection Type Start Date Checklist Item BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Checklist Item BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final 01/19/2022 BLDG-Final Inspection Tuesday, May 24, 2022 Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Issue Date: 12/23/2020 Subdivision: Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Inspection No. COMMENTS Inspection Status January 11, 2022: Primary Inspector 1. Final walk-through, first floor locations memory care building, dwelling units (only) -partial pass. January 11, 2022: 1. Final walk-through, first floor locations memory care building, dwelling units (only) -partial pass. January 11, 2022: 1. Final walk-through, first floor locations memory care building, dwelling units (only) -partial pass. January 11, 2022: 1. Final walk-through, first floor locations memory care building, dwelling units (only) -partial pass. COMMENTS January 11, 2022: 1. Final walk-through, first floor locations memory care building, dwelling units (only) -partial pass. January 11, 2022: 1. Final walk-through, first floor locations memory care building, dwelling units (only) -partial pass. January 11, 2022: 1. Final walk-through, first floor locations memory care building, dwelling units (only) -partial pass. January 11, 2022: 1. Final walk-through, first floor locations memory care building, dwelling units (only) -partial pass. 17 4 777-2022 Partial Pass Tony Alvarado Reinspection Inspection Passed Yes Yes Yes Yes Passed Yes Yes Yes Yes Reinspection Incomplete Page 45 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Issue Date: 12/23/2020 Subdivision: Status: Scheduled Date 12/07/2021 01/07/2022 01/11/2022 Closed -Finaled Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector BLDG-82 Drywall, 172041-2021 Passed Tony Alvarado Exterior Lath, Gas Test, Hot Mop Checklist Item COMMENTS BLDG-17 Interior Lath-Drywall December 6, 2021: 12/07/2021 BLDG-Gas Meter Release Checklist Item 1. Interior drywall Gypsum Board-Final approval. 2. Thermal insulation-final approval. 172121-2021 Passed Tony Alvarado COMMENTS BLDG-Building Deficiency December 7, 2021: 01/07/2022 BLDG-Final Inspection Checklist Item BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final 01/11/2022 BLDG-Final Inspection 1. Gas plumbing line Air pressure leak-test approved. 2. Released per email gas meters: to SDGE newserv department. 3. Building addresses: 2540 and 2560 Faraday Ave., gas meter released-approved. 17 4086-2022 COMMENTS January 7, 2022: Partial Pass Tony Alvarado 1. Memory care building, first floor level, dwelling units (only), partial pass for final Inspection walk-throughs. 2. No common areas or Corridor's are ready, Rest of work-OK. January 7, 2022: 1. Memory care building, first floor level, dwelling units (only), partial pass for final Inspection walk-throughs. 2. No common areas or Corridor's are ready, Rest of work-OK. January 7, 2022: 1. Memory care building, first floor level, dwelling units (only), partial pass for final Inspection walk-throughs. 2. No common areas or Corridor's are ready, Rest of work-OK. January 7, 2022: 1. Memory care building, first floor level, dwelling units (only), partial pass for final Inspection walk-throughs. 2. No common areas or Corridor's are ready, Rest of work-OK. 174175-2022 Partial Pass Tony Alvarado Reinspection Inspection Complete Passed Yes Complete Passed Yes Reinspection Incomplete Passed Yes Yes Yes Yes Reinspection Incomplete Tuesday, May 24, 2022 Page 44 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Issue Date: 12/23/2020 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Status: Closed -Finaled Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection 12/03/2021 12/06/2021 Checklist Item BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers COMMENTS December 2, 2021: 1. Memory care building, phase D, second floor, dwelling units and common areas, metal frame drop ceilings, above MEPS combination inspection-Final approved. December 2, 2021: 1. Memory care building, phase D, second floor, dwelling units and common areas, metal frame drop ceilings, above MEPS combination inspection-Final approved. December 2, 2021: 1. Memory care building, phase D, second floor, dwelling units and common areas, metal frame drop ceflings, above MEPS combination inspection-Final approved. December 2, 2021: 1. Memory care building, phase D, second floor, dwelling units and common areas, metal frame drop ceilings, above MEPS combination inspection-Final approved. 12/03/2021 BLDG-17 Interior Lath/Drywall 171864-2021 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS December 3, 2021: (Final drywall), memory care building -approved. 1. Interior drywall, memory care building, phase D, second level, dwelling units and common areas, drywall anchoring -Final drywall approval. December 2, 2021: 1. Interior drywall, memory care building, phase D, second level, dwelling units and common areas, drywall anchoring -partial pass. 12/06/2021 BLDG-16 Insulation Checklist Item 172037-2021 COMMENTS Passed Tony Alvarado BLDG-Building Deficiency December 6, 2021: 1. Interior drywall Gypsum Board-Final approval. 2. Thermal insulation-final approval. BLDG-18 Exterior Lath/Drywall 171933-2021 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS December 6, 2021: 1. Interior drywall Gypsum Board-Final approval. 2. Thermal insulation-final approval. Tuesday, May 24, 2022 Passed Yes Yes Yes Yes Complete Passed Yes Yes Complete Passed Yes Complete Passed Yes Page 43 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Issue Date: 12/23/2020 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Status: Scheduled Date Closed -Finaled Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS December 2, 2021: 1. Interior drywall, memory care building, phase D, second level, dwelling units and common areas, drywall anchoring -partial pass. October 21, 2021: (Partial pass) memory care building, phase B, (continuous)-insulation and drywall work. 1. First floor, memory care Building, phase A (Basement), common area locations, title 24 energy efficient-thermal insulation installation: type, size, installation methods -approved. 2. Drywall/gypsum board; type, size, and anchoring schedule, per plan -partial approval. BLDG-84 Rough Combo(14,24,34,44) 171601-2021 Partial Pass Tony Alvarado Checklist Item BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers BLDG-44 Rough-Ducts-Dampers COMMENTS December 1, 2021: 1. Memory care building, phase D, second floor, dwelling units and common areas, metal frame drop ceilings, above MEPS combination inspection-partial pass. December 1, 2021: 1. Memory care building, phase D, second floor, dwelling units and common areas, metal frame drop ceilings, above MEPS combination inspection-partial pass. December 1, 2021: 1. Memory care building, phase D, second floor, dwelling units and common areas, metal frame drop ceilings, above MEPS combination inspection-partial pass. December 1, 2021: 1. Memory care building, phase D, second floor, dwelling units and common areas, metal frame drop ceilings, above MEPS combination inspection-partial pass. November 22, 2021: 1. Memory care building, basement level - drop ceilings overhead-approved. 2. Drywall nail located at stairwell from 1st to 200 level area-approved. 3. Second level, phase D, drywall nail-approved. 4. Assisted living building -third-floor partial pass, drywall nailing -approved. Reinspection Inspection Passed Yes Yes Reinspection Incomplete Passed Yes Yes Yes Yes Yes Tuesday, May 24, 2022 Page 42 of 50 Permit Type: Work Class: Status: Scheduled Date 12/02/2021 PERMIT INSPECTION HISTORY for {CBC2019-0530} BLDG-Commercial Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC New Issue Date: 12/23/2020 Subdivision: Closed -Finaled Expiration Date: 09/27/2022 Address: 2540 FARADAY AVE Actual Start Date IVR Number: 23094 CARLSBAD, CA 92008 Inspection Type Inspection No. Inspection Primary Inspector Reinspection Checklist Item BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers BLDG-44 Rough-Ducts-Dampers Status COMMENTS November 22, 2021: 1. Memory care building, basement level - drop ceilings overhead-approved. 2. Drywall nail located at stairwell from 1st to 2nd level area-approved. 3. Second level, phase D, drywall nail-approved. 4. Assisted living building -third-floor partial pass, drywall nailing -approved. November 22, 2021: 1. Memory care building, basement level - drop ceilings overhead-approved. 2. Drywall nail located at stairwell from 1st to 2nd level area-approved. 3. Second level, phase D, drywall nail-approved. 4. Assisted living building -third-floor partial pass, drywall nailing -approved. November 22, 2021: 1. Memory care building, basement level - drop ceilings overhead-approved. 2. Drywall nail located at stairwell from 1st to 2nd level area-approved. 3. Second level, phase D, drywall nail-approved. 4. Assisted living building -third-floor partial pass, drywall nailing -approved. November 22, 2021: 1. Memory care building, basement level - drop ceilings overhead-approved. 2. Drywall nail located at stairwell from 1st to 2nd level area-approved. 3. second level, phase D, drywall nail-approved. 4. Assisted living building -third-floor partial pass, drywall nailing -approved. September 10, 2021: 1. No rough combination (MEPS)/building Deficiencies. 2. Assisted living building, section 9, third floor, up to and including units #304-Partial pass. 3. MEPS, metal drop ceiling locations-(only), rough combination inspection-partial approved. Passed Yes Yes Yes Yes Yes Inspection 12/02/2021 BLDG-17 Interior Lath/Drywall 171743-2021 Partial Pass Tony Alvarado Reinspection Incomplete Tuesday, May 24, 2022 Page 41 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Status: Closed -Finaled Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Issue Date: 12/23/2020 Subdivision: Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Tuesday, May 24, 2022 Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS November 22, 2021: 1. Memory care building, basement level - drop ceilings overhead-approved. 2. Drywall nail located at stairwell from 1st to 2nd level area-approved. 3. Second level, phase D, drywall nail-approved. 4. Assisted living building -third-floor partial pass, drywall nailing -approved. October 21, 2021: (Partial pass) memory care building, phase B, (continuous)-insulation and drywall work. 1. First floor, memory care Building, phase A (Basement), common area locations, title 24 energy efficient-thermal insulation installation: type, size, installation methods -approved. 2. Drywall/gypsum board; type, size, and anchoring schedule, per plan -partial approval. November 15, 2021: (Partial pass) memory care building, (continuous) -insulation and drywall work. 1. 2nd. floor, memory care Building, phase A (Basement), common area locations, title 24 energy efficient-thermal insulation installation: type, size, installation methods -partial approved. 2. Drywall/gypsum board; type, size, and anchoring schedule, per plan -partial approval. BLDG-84 Rough Combo(14,24,34,44) 171247-2021 Partial Pass Tony Alvarado Passed Yes Yes Yes Reinspection Incomplete Page 40 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Issue Date: 12/23/2020 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Status: Scheduled Date 11/23/2021 Closed -Finaled Expiration Date: 09/27/2022 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 IVR Number: Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Checklist Item BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers COMMENTS Metal frame drop ceilings, rough combination above metal drop ceiling areas, electrical, plumbing, mechanical, with fire caulking at all penetrations-approved. Drywall fastening anchoring system per plan-approved. Memory care building, second floor, phase D & E Approved. Metal frame drop ceilings, rough combination above metal drop ceiling areas, electrical, plumbing, mechanical, with fire caulking at all penetrations-approved. Drywall fastening anchoring system per plan-approved. Memory care building, second floor, phase D & E Approved. Metal frame drop ceilings, rough combination above metal drop ceiling areas, electrical, plumbing, mechanical, with fire caulking at all penetrations-approved. Drywall fastening anchoring system per plan-approved. Memory care building, second floor, phase D & E Approved. Metal frame drop ceilings, rough combination above metal drop ceiling areas, electrical, plumbing, mechanical, with fire caulking at all penetrations-approved. Drywall fastening anchoring system per plan-approved. Memory care building, second floor, phase D & E Approved. 11/23/2021 BLDG-17 Interior Lath/Drywall 171245-2021 Partial Pass Tony Alvarado Reinspection Inspection Passed Yes Yes Yes Yes Reinspection Incomplete Tuesday, May 24, 2022 Page 39 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Issue Date: 12/23/2020 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Status: Scheduled Date 11/17/2021 11/19/2021 Closed -Finaled Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Checklist Item BLOG-Building Deficiency BLDG-Building Deficiency COMMENTS November 15, 2021: (Partial pass) memory care building, (continuous) -insulation and drywall work. 1. 2nd. floor, memory care Building, phase A (Basement), common area locations, title 24 energy efficient-thermal insulation installation: type, size, installation methods -partial approved. 2. Drywall/gypsum board; type, size, and anchoring schedule, per plan -partial approval. October 21, 2021: (Partial pass) memory care building, phase B, (continuous)-insulation and drywall work. 1. First floor, memory care Building, phase A (Basement), common area locations, title 24 energy efficient-thermal insulation installation: type, size, installation methods -approved. 2. Drywall/gypsum board; type, size, and anchoring schedule, per plan -partial approval. 11/17/2021 BLDG-17 Interior Lath/Drywall 170926-2021 Partial Pass Tony Alvarado Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS October 21, 2021: (Partial pass) memory care building, phase B, (continuous)-insulation and drywall work. 1. First floor, memory care Building, phase A (Basement), common area locations, title 24 energy efficient-thermal insulation installation: type, size, installation methods -approved. 2. Drywall/gypsum board: type, size, and anchoring schedule, per plan -partial approval. November 15, 2021: (Partial pass) memory care building, (continuous) -insulation and drywall work. 1. 2nd. floor, memory care Building, phase A (Basement), common area locations, title 24 energy efficient-thermal insulation installation: type, size, installation methods -partial approved. 2. Drywall/gypsum board; type, size, and anchoring schedule, per plan -partial approval. 11/19/2021 BLDG-84 Rough Combo(14,24,34,44) 171117-2021 Passed Tony Alvarado Reinspection Inspection Passed Yes Yes Reinspection Incomplete Passed Yes Yes Complete Tuesday, May 24, 2022 Page 38 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Issue Date: 12/23/2020 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Status: Scheduled Date 11/10/2021 11/15/2021 Closed -Finaled Expiration Date: 09/27/2022 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Actual Inspection Type Start Date 11/10/2021 BLDG-16 Insulation Checklist Item IVR Number: Inspection No. 170548-2021 COMMENTS Inspection Status Primary Inspector Partial Pass Tony Alvarado BLDG-Building Deficiency November 9, 2021: (Partial pass) memory care building, phase B, (continuous) insulation-No building Deficiencies. BLDG-Building Deficiency BLDG-Building Deficiency 1. First floor, memory care Building, phase E, common areas and dwelling units locations, title 24 energy efficient-thermal insulation installation: type, size, installation methods -approved. 2. Drywall/gypsum board; type, size, and anchoring schedule, per plan -partial approval. November 10, 2021: (Partial pass) memory care building, phase E, (continuous) insulation-No building Deficiencies. 1. Second floor, memory care Building, phase E, common areas and dwelling units locations, title 24 energy efficient-thermal insulation installation: type, size, installation methods -approved. 2. Drywall/gypsum board; type, size, and anchoring schedule, per plan -partial approval. October 21, 2021: (Partial pass) memory care building, phase B, (continuous)-insulation and drywall work. 1. First floor, memory care Building, phase A (Basement), common area locations, title 24 energy efficient-thermal insulation installation: type, size, installation methods -approved. 2. Drywall/gypsum board; type, size, and anchoring schedule, per plan -partial approval. 11/15/2021 BLDG-17 Interior Lath/Drywall 170747-2021 Partial Pass Tony Alvarado Reinspection Inspection Reinspection Incomplete Passed Yes Yes Yes Reinspection Incomplete Tuesday, May 24, 2022 Page 37 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530} Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Issue Date: 12/23/2020 Subdivision: Status: Scheduled Date 11/09/2021 Closed -Finaled Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS October 21, 2021: (Partial pass) memory care building, phase B, (continuous)-insulation and drywall work. 1 First floor, memory care Building, phase A (Basement), common area locaUons, title 24 energy efficient-thermal insulation installation: type, size, installation methods -approved. 2. Drywall/gypsum board; type, size, and anchoring schedule, per plan -partial approval. October 12, 2021: (Partial Pass). 1. Interior gypsum board/drywall method of attachment anchoring, first floor, memory care building, phase 8, Gypsum/Drywall board, dwelling units, common areas and office areas-scope of work -approved. November 3, 2021: (Partial Pass). 1. Memory care building, Interior gypsum board/drywall method of attachment anchoring, first floor, phase B & C sections, dwelling units, common areas and office areas, Drop ceiling-metal lid locations, scope of drywall work - Approved. 11/09/2021 BLDG-16 Insulation Checklist Item 170435-2021 COMMENTS Partial Pass Tony Alvarado BLDG-Building Deficiency BLDG-Building Deficiency October 21, 2021: (Partial pass) memory care building, phase B, (continuous)-insulation and drywall work. 1. First floor, memory care Building, phase A (Basement), common area locations, title 24 energy efficient-thermal insulation installation: type, size, installation methods -approved. 2. Drywall/gypsum board; type, size, and anchoring schedule, per plan -partial approval. November 9, 2021: (Partial pass) memory care building, phase B, (continuous) insulation-No building Deficiencies. 1. First floor, memory care Building, phase E, common areas and dwelling units locations, title 24 energy efficient-thermal insulation installation: type, size, installation methods -approved. 2. Drywall/gypsum board; type, size, and anchoring schedule, per plan -partial approval. Reinspection Inspection Passed Yes Yes Yes Reinspection Incomplete Passed Yes Yes Tuesday, May 24, 2022 Page 36 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Work Class: New Issue Date: 12/23/2020 Subdivision: Status: Closed -Finaled Expiration Date: 09/27/2022 Address: 2540 FARADAY AVE IVR Number: 23094 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status BLDG-14 169440-2021 Cancelled Peter Dreibelbis Re inspection Incomplete Frame/Steel/Bolting/We lding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Cancelled No 10/2812021 10128/2021 BLDG-17 Interior 169660-2021 Partial Pass Tony Alvarado Re inspection Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency October 28, 2021: (Partial Pass). Yes (No deficiencies). 1. Memory care building, phase C, first floor, common areas-(only), partial drywall/gypsum board attachment-(only), scope of drywall work-partial Pass. BLDG-Building Deficiency October 25, 2021: (Partial Pass). Yes (No deficiencies). 1. Memory care building, phase C, first floor, Partial drywall/gypsum board attachment-(only), scope of drywall work-partial Pass. BLDG-Building Deficiency October 6, 2021: (Partial Pass). Yes 1. Interior gypsum board/drywall method of attachment anchoring, first floor, memory care building, phase B, Gypsum/Drywall board, dwelling units-(only), scope of work -approved. 11/0312021 11103/2021 BLDG-17 Interior 169943-2021 Partial Pass Tony Alvarado Reinspection Incomplete Lath/Drywall Tuesday, May 24, 2022 Page 35 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Status: Scheduled Date 10/27/2021 Issue Date: 12/23/2020 Closed -Finaled Expiration Date: 09/27/2022 IVR Number: 23094 Subdivision: Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection 10/27/2021 Checklist Item BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers BLDG-44 Rough-Ducts-Dampers COMMENTS October 26, 2021: 1. Memory care building, first floor, phase B, drop metal ceiling lids, preliminary rough combination and fire penetrations sealed with rated Approved fire sealant, scope of work-approved. October 26, 2021: 1. Memory care building, first floor, phase B, drop metal ceiling lids, preliminary rough combination and fire penetrations sealed with rated Approved fire sealant, scope of work-approved. October 26, 2021: 1. Memory care building, first floor, phase B, drop metal ceiling lids, preliminary rough combination and fire penetrations sealed with rated Approved fire sealant, scope of work-approved. September 1 0, 2021 : 1. No rough combination (MEPS)/building Deficiencies. 2. Assisted living building, section 9, third floor, up to and including units #304-Partial pass. 3. MEPS, metal drop ceiling locations-(only), rough combination inspection-partial approved. October 26, 2021: 1. Memory care building, first floor, phase B, drop metal ceiling lids, preliminary rough combination and fire penetrations sealed with rated Approved fire sealant, scope of work-approved. BLDG-Electric Meter Release 169445-2021 Passed Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS October 27, 2021 : No electrical meter, transformer and switch gear Deficiencies. 1. No electrical meter release for transformer and switchgear room/meter locations. 2. Cabinet method of attachment anchoring -verified torqued lugs Per engineered specifications-approved . 3. Electrical meter panel bus bar-verified torqued lugs-approved per engineered specifications-approved . Passed Yes Yes Yes Yes Yes Complete Passed Yes Tuesday, May 24, 2022 Page 34 of 50 PERMIT INSPECTION HISTORY for {CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Status: Closed -Finaled Scheduled Actual Inspection Type Date Start Date 10/26/2021 10/26/2021 BLDG-33 Service Change/Upgrade Checklist Item Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Issue Date: 12/23/2020 Subdivision: Expiration Date: 09/27/2022 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 IVR Number: 23094 Inspection No. Inspection Primary Inspector Reinspection Inspection Status 169444-2021 Passed Tony Alvarado Complete COMMENTS Passed BLDG-Building Deficiency October 27, 2021: Yes Tuesday, May 24, 2022 BLDG-84 Rough Combo(14,24,34,44) No electrical meter, transformer and switch gear Deficiencies. 1. No electrical meter release for transformer and switchgear room/meter locations. 2. Cabinet method of attachment anchoring -verified torqued lugs Per engineered specifications-approved. 3. Electrical meter panel bus bar-verified torqued lugs-approved per engineered specifications-approved. 4. Grounding and bonding Verified and Torqued lugs-approved. 5. Released electrical meter to SDGE. 169337-2021 Partial Pass Tony Alvarado Reinspection Incomplete Page 33 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Status: Closed -Finaled Application Date: 11/14/2019 Issue Date: 12/23/2020 Expiration Date: 09/27/2022 IVR Number: 23094 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS October 19, 2021: (Partial Pass). 1. Interior gypsum board/drywall method of attachment anchoring, first floor, memory care building, phase B & C, Gypsum/Drywall board, dwelling units, common areas and office areas-scope of work -partial pass. 2. Memory care building, phase C, first floor, MEPS/rough combination inspection at ceiling lid areas -(only), scope of work-partial Pass. October 21, 2021: (Partial pass) memory care building, phase B, {continuous)-insulation and drywall work. 1. First floor, memory care Building, phase A (Basement), common area locations, title 24 energy efficient-thermal insulation installation: type, size, installation methods -approved. 2. Drywall/gypsum board; type, size, and anchoring schedule, per plan -partial approval. October 12, 2021: (Partial Pass). 1. Interior gypsum board/drywall method of attachment anchoring, first floor, memory care building, phase B, Gypsum/Drywall board, dwelling units, common areas and office areas-scope of work-approved. 10/25/2021 10/25/2021 BLDG-17 Interior Lath/Drywall 169219-2021 Partial Pass Tony Alvarado Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency Tuesday, May 24, 2022 COMMENTS October 6, 2021: (Partial Pass). 1. Interior gypsum board/drywall method of attachment anchoring, first floor, memory care building, phase 8, Gypsum/Drywall board, dwelling units-{only), scope of work -approved. October 8, 2021: (Partial Pass). 1. Interior gypsum board/drywall method of attachment anchoring, 1st, floor, memory care building, phase B & C. Preliminary ceilings-Gypsum/Drywall board, common areas and dwelling units-(only), scope of work -First floor entire areas approved. October 25, 2021: (Partial Pass). {No deficiencies). 1. Memory care building, phase C, first floor, Partial drywall/gypsum board attachment-(only), scope of drywall work-partial Pass. Passed Yes Yes Yes Reinspection Incomplete Passed Yes Yes Yes Page 32 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Issue Date: 12/23/2020 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Status: Scheduled Date 10/2112021 Closed -Finaled Expiration Date: 09/27/2022 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 IVR Number: Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Checklist Item BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers COMMENTS October 20, 2021: partial pass 1. Memory care building, insulation and MEPS/rough combination on vertical wall common areas (only) and dwelling units-approved. October 20, 2021: partial pass 1. Memory care building, insulation and MEPS/rough combination on vertical wall common areas (only) and dwelling units-approved. October 20, 2021: partial pass 1. Memory care building, insulation and MEPS/rough combination on vertical wall common areas (only) and dwelling units-approved. October 20, 2021: partial pass 1. Memory care building, insulation and MEPS/rough combination on vertical wall common areas (only) and dwelling units-approved. 10/21/2021 BLDG-16 Insulation Checklist Item 169035-2021 COMMENTS Partial Pass Tony Alvarado BLDG-Building Deficiency BLDG-Building Deficiency October 6, 2021: Partial pass memory care building, phase B, first floor-continuous. 1. First floor, memory care Building, phase B, dwelling unit locations, title 24 energy efficient-thermal insulation installation: type, size, installation methods -approved. October 21, 2021: (Partial pass) memory care building, phase B, (continuous)-insulation and drywall work. 1. First floor, memory care Building, phase A (Basement), common area locations, title 24 energy efficient-thermal insulation installation: type, size, installation methods -approved. 2. Drywall/gypsum board; type, size, and anchoring schedule, per plan -partial approval. BLDG-17 Interior Lath/Drywall 169122-2021 Partial Pass Tony Alvarado Reinspection Inspection Passed Yes Yes Yes Yes Reinspection Incomplete Passed Yes Yes Reinspection Incomplete Tuesday, May 24, 2022 Page 31 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Issue Date: 12/23/2020 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Status: Scheduled Date 10/20/2021 Closed -Finaled Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Checklist Item BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers BLDG-44 Rough-Ducts-Dampers COMMENTS October 19, 2021: (Partial Pass). 1. Memory care building, phase C, first floor, MEPS/rough Metal frame dropped ceiling lid areas -(only), scope of work-partial Pass. 2. Fire resistant, one hour fire caulking red compound sealed at all penetrations, scope of work-approved. October 19, 2021: (Partial Pass). 1. Memory care building, phase C, first floor, MEPS/rough Metal frame dropped ceiling lid areas -(only), scope of work-partial Pass. 2. Fire resistant, one hour fire caulking red compound sealed at all penetrations, scope of work-approved. October 19, 2021: (Partial Pass). 1. Memory care building, phase C, first floor, MEPS/rough Metal frame dropped ceiling lid areas -(only), scope of work-partial Pass. 2. Fire resistant. one hour fire caulking red compound sealed at all penetrations, scope of work-approved. October 19, 2021: (Partial Pass). 1. Memory care building, phase C, first floor, MEPS/rough Metal frame dropped ceiling lid areas -(only), scope of work-partial Pass. 2. Fire resistant, one hour fire caulking red compound sealed at all penetrations. scope of work-approved. September 10, 2021: 1. No rough combination (MEPS)/building Deficiencies. 2. Assisted living building, section 9, third floor, up to and including units #304-Partial pass. 3. MEPS. metal drop ceiling locations-(only), rough combination inspection-partial approved. 10120/2021 BLDG-84 Rough Combo(14,24,34,44) 168891-2021 Partial Pass Tony Alvarado Reinspection Inspection Passed Yes Yes Yes Yes Yes Reinspection Incomplete Tuesday, May 24, 2022 Page 30 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Status: Closed -Finaled Application Date: 11/14/2019 Issue Date: 12/23/2020 Expiration Date: 09/27/2022 IVR Number: 23094 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Tuesday, May 24, 2022 Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS October 8, 2021: (Partial Pass). 1. Interior gypsum board/drywall method of attachment anchoring, 1st, floor, memory care building, phase B & C. Preliminary ceilings-Gypsum/Drywall board, common areas and dwelling units-(only), scope of work -First floor entire areas approved. October 6, 2021: {Partial Pass). 1. Interior gypsum board/drywall method of attachment anchoring, first floor, memory care building, phase B, Gypsum/Drywall board, dwelling units-(only), scope of work -approved. October 19, 2021: (Partial Pass). (No deficiencies}. 1. Memory care building, phase C, first floor, MEPS/rough Metal frame dropped ceiling lid areas-(only), scope of work-partial Pass. 2. Fire resistant, one hour fire caulking red compound sealed at all penetrations, scope of work-approved. COMMENTS October 19, 2021: (Partial Pass). 1. Interior gypsum board/drywall method of attachment anchoring, first floor, memory care building, phase B & C, Gypsum/Drywall board, dwelling units, common areas and office areas-scope of work -partial pass. 2. Memory care building, phase C, first floor, MEPS/rough combination inspection at ceiling lid areas -(only), scope of work-partial Pass. October 12, 2021: (Partial Pass). 1. Interior gypsum board/drywall method of attachment anchoring, first floor, memory care building, phase B, Gypsum/Drywall board, dwelling units, common areas and office areas-scope of work -approved. BLDG-84 Rough Combo(14,24,34,44) 168919-2021 Partial Pass Tony Alvarado Passed Yes Yes Yes Passed Yes Yes Reinspection Incomplete Page 29 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Issue Date: 1212312020 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Status: Scheduled Date 10/19/2021 Closed -Finaled Expiration Date: 0912712022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Checklist Item BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers COMMENTS September 10, 2021: 1. No rough combination (MEPS)/building Deficiencies. 2. Assisted living building, section 9, third floor, up to and including units #304-Partial pass. 3. MEPS, metal drop ceiling locations-(only), rough combination inspection-partial approved. September 10, 2021: 1. No rough combination (MEPS)/building Deficiencies. 2. Assisted living building, section 9, third floor, up to and including units #304-Partial pass. 3. MEPS, metal drop ceiling locations-(only), rough combination inspection-partial approved. September 10, 2021: 1. No rough combination (MEPS)/building Deficiencies. 2. Assisted living building, section 9, third floor, up to and including units #304-Partial pass. 3. MEPS, metal drop ceiling locations-(only), rough combination inspection-partial approved. September 10, 2021: 1. No rough combination (MEPS)/bui1ding Deficiencies. 2. Assisted living building, section 9, third floor, up to and including units #304-Partial pass. 3. MEPS, metal drop ceiling locations-(only), rough combination inspection-partial approved. COMMENTS 10/19/2021 BLDG-17 Interior Lath/Drywall 168886-2021 Partial Pass Tony Alvarado Reinspection Inspection Passed Yes Yes Yes Yes Passed No No No No No Reinspection Incomplete Tuesday, May 24, 2022 Page 28 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Status: Scheduled Date 10/12/2021 10/13/2021 Issue Date: 12/23/2020 Closed -Finaled Expiration Date: 09/27/2022 IVR Number: 23094 Subdivision: Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection 10/12/2021 10/13/2021 Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS October 8, 2021: (Partial Pass). 1. Interior gypsum board/drywall method of attachment anchoring, 1st, floor, memory care building, phase B & C. Preliminary ceilings-Gypsum/Drywall board, common areas and dwelling units-(only), scope of work -First floor entire areas approved. October 6, 2021: (Partial Pass). 1. Interior gypsum board/drywall method of attachment anchoring, first floor, memory care building, phase 8, Gypsum/Drywall board, dwelling units-(only), scope of work -approved. BLDG-17 Interior 168300-2021 Partial Pass Tony Alvarado Lath/Drywall Checklist Item COMMENTS BLDG-Building Deficiency October 12, 2021: (Partial Pass). 1. Interior gypsum board/drywall method of attachment anchoring, first floor, memory care building, phase B, Gypsum/Drywall board, dwelling units, common areas and office areas-scope of work -approved. BLDG-84 Rough 168386-2021 Cancelled Tim Kersch Combo(14,24,34,44) Passed Yes Yes Re inspection Incomplete Passed Yes Reinspection Incomplete Tuesday, May 24, 2022 Page 27 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Issue Date: 12/23/2020 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Status: Scheduled Date 10/07/2021 10/08/2021 Closed -Finaled Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector 10/07/2021 10/08/2021 BLDG-17 Interior Lath/Drywall 167950-2021 Partial Pass Tony Alvarado Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS June 22, 2021: 1. No Building, insulation, drywall, floor nailing or MEPS Deficiencies. 2. Phase 4, first floor, corridor locations, final gypsum/drywall completed interior corridors-approved. 3. memory care building, section 3 & 4 second floor, sole plate and sub-floor plywood nailing pattern-approved. July 13, 2021: 1. No gypsum board/drywall Building Deficiencies. 2. Memory care building, phase B &C, first floor level, tub/ shower enclosures, preliminary-moisture resistive, (cement green board), scope of work; type, size, and method of attachment anchoring System-Approved. October 6, 2021: (Partial Pass). 1. Interior gypsum board/drywall method of attachment anchoring, first floor, memory care building, phase B, Gypsum/Drywall board, dwelling units-{only), scope of work -approved. BLDG-17 Interior 168163-2021 Partial Pass Tony Alvarado Lath/Drywall Checklist Item COMMENTS BLDG-Building Deficiency October 7, 2021: (Partial Pass). 1. Interior gypsum board/drywall method of attachment anchoring, first floor, memory care building, phase B, Gypsum/Drywall board, dwelling units-(only), scope of work -approved. BLDG-17 Interior 168252-2021 Partial Pass Tony Alvarado Lath/Drywall Reinspection Inspection Reinspection Incomplete Passed Yes Yes Yes Reinspection Incomplete Passed Yes Reinspection Incomplete Tuesday, May 24, 2022 Page 26 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Issue Date: 12/23/2020 Subdivision: Status: Scheduled Date 10/06/2021 Closed -Finaled Expiration Date: 09/27/2022 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 IVR Number: Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS September 29, 2021-(Partial pass). 1. Energy-efficient thermal insulation installation, Units completed memory care building. 2. First floor, memory care Building, Tub and shower bathroom dwelling unit locations, exterior wall, title 24 energy efficient-insulation installation: type, size, installation methods -approved. October 1, 2021-(Partial pass). 1. Energy-efficient thermal insulation installation, Units completed memory care building. 2. First floor, memory care Building, phase B, dwelling unit locations, title 24 energy efficient-thermal insulation installation: type, size, installation methods -approved. July 12, 2021: Canceled/work not ready. 1. pre-liminary tub/shower-insulation installation Deficiencies. 2. First floor, memory care Building, Tub and shower bathroom dwelling unit locations, exterior wall, title 24 energy efficient-insulation installation: type, size, installation methods -Not completed or approved. 10/06/2021 BLDG-16 Insulation Checklist Item 167949-2021 COMMENTS Partial Pass Tony Alvarado BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency September 29, 2021-(Partial pass). 1. Energy-efficient thermal insulation installation, Units completed memory care building. 2. First floor, memory care Building, Tub and shower bathroom dwelling unit locations, exterior wall, title 24 energy efficient-insulation installation: type, size, installation methods -approved. October 1, 2021-(Partial pass). 1. Energy-efficient thermal insulation installation, Units completed memory care building. 2. First floor, memory care Building, phase B, dwelling unit locations, title 24 energy efficient-thermal insulation installation: type, size, installation methods -approved. October 6, 2021: Partial pass memory care building, phase B, first floor-continuous. 1. First floor, memory care Building, phase B, dwelling unit locations, title 24 energy efficient-thermal insulation installation: type, size, installation methods-approved. Reinspection Inspection Passed Yes Yes No Reinspection Incomplete Passed Yes Yes Yes Tuesday, May 24, 2022 Page 25 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Issue Date: 12/23/2020 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Status: Scheduled Date 09/30/2021 10/01/2021 Closed -Finaled Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS July 9, 2021: 1. No pre-liminary tub/shower-insulation installation Deficiencies. 2. First floor, memory care Building, Tub and shower bathroom dwelling unit locations, exterior wall, title 24 energy efficient-insulation installation: type, size, installation methods -approved. September 29, 2021-(Partial pass). 1. Energy-efficient thermal insulation installation, Units completed memory care building. 2. First floor, memory care Building, Tub and shower bathroom dwelling unit locations, exterior wall, title 24 energy efficient-insulation installation: type, size, installation methods -approved. July 12, 2021: Canceled/work not ready. 1. pre-liminary tub/shower-insulation installation Deficiencies. 2. First floor, memory care Building, Tub and shower bathroom dwelling unit locations, exterior wall, title 24 energy efficient-insulation installation: type, size, installation methods -Not completed or approved. 09/30/2021 BLDG-16 Insulation Checklist Item 167610-2021 COMMENTS Partial Pass Tony Alvarado BLDG-Building Deficiency September 30, 2021: (partial pass). 1. Interior energy-efficient, thermal insulation method of attachment anchoring, scope of work -approved. 2. Memory care building, first floor areas, phase 3 location, dwelling units: #101 through #120. common areas, and corridor Location-Approved. 10/01/2021 BLDG-16 Insulation 167686-2021 Partial Pass Tony Alvarado Reinspection Inspection Passed Yes Yes No Reinspection Incomplete Passed Yes Reinspection Incomplete Tuesday, May 24, 2022 Page 24 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Status: Closed -Finaled Application Date: 11/14/2019 Issue Date: 12/23/2020 Expiration Date: 09/27/2022 IVR Number: 23094 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS September 14, 2021: 1. No rough plumbing top out-building Deficiencies. 2. Memory care building, first and second floor, waste and vent and water plumbing lines, under 10' foot high head pressure water leak test, entire building-completed and approved. 3. memory care entire building completed for rough plumbing top out, and roof drains under water leak pressure test, scope of work-approved. 4. Low pressure gas lines, under air pressure leak test, memory care building completed, scope of gas test Inspection - approved. July 7, 2021: 1. No Building Deficiencies. 2. Memory care building, first floor, basement level, rough plumbing top-out. waste and vent lines, under water leak pressure test-approved. September 13, 2021: 1. No rough plumbing top out-building Deficiencies. 2. Memory care building, first and second floor, waste and vent plumbing lines, under 1 O' foot high head pressure water leak test, entire-partial pass. 3. memory care entire building completed for rough plumbing top out, scope of work-partial approved. 09/29/2021 0912912021 BLDG-16 Insulation 167536-2021 Partial Pass Tony Alvarado Tuesday, May 24, 2022 Passed Yes Yes Yes Reinspection Incomplete Page 23 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Status: Closed -Finaled Issue Date: 12/23/2020 Subdivision: Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS September 13, 2021: 1. No rough plumbing top out-building Deficiencies. 2. Memory care building, first and second floor, waste and vent plumbing lines, under 1 O' foot high head pressure water leak test, entire-partial pass. 3. memory care entire building completed for rough plumbing top out, scope of work-partial approved. July 7, 2021: 1. No Building Deficiencies. 2. Memory care building, first floor, basement level, rough plumbing top-out, waste and vent lines, under water leak pressure test-approved. 09/14/2021 09/14/2021 BLDG-23 166450-2021 Passed Tony Alvarado Tuesday, May 24, 2022 Gas!Test/Repairs Checklist Item BLDG-Building Deficiency COMMENTS September 14, 2021: (Gas pressure test). 1. No rough plumbing top out and gas pressure test-building Deficiencies. 2. Memory care building, first and second floor, waste and vent and water plumbing lines, under 1 0' foot high head pressure water leak test, entire building-completed and approved. 3. memory care entire building completed for rough plumbing top out, and roof drains under water leak pressure test, scope of work-approved. 4. Low pressure gas lines, under air pressure leak test, memory care butlding completed, scope of gas test Inspection - approved. BLDG-24 Rough/Topout 166403-2021 Passed Tony Alvarado Passed Yes Yes Complete Passed Yes Complete Page 22 of 50 Permit Type: Work Class: Status: Scheduled Date 09/13/2021 PERMIT INSPECTION HISTORY for (CBC2019-0530) BLDG-Commercial Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC New Issue Date: 12/23/2020 Subdivision: Closed -Finaled Expiration Date: 09/27/2022 Address: 2540 FARADAY AVE Actual Start Date IVR Number: 23094 CARLSBAD, CA 92008 Inspection Type Inspection No. Inspection Primary Inspector Reinspection Checklist Item BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLOG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers Status COMMENTS September 10, 2021: 1. No rough combination (MEPS)/building Deficiencies. 2. Assisted living building, section 9, third floor, up to and including units #304-Partial pass. 3. MEPS, metal drop ceiling locations-(only), rough combination inspection-partial approved. September 10, 2021: 1. No rough combination (MEPS)/building Deficiencies. 2. Assisted living building, section 9, third floor, up to and including units #304-Partial pass. 3. MEPS, metal drop ceiling locations-(only), rough combination inspection-partial approved. September 10, 2021: 1. No rough combination (MEPS)/building Deficiencies. 2. Assisted living building, section 9, third floor, up to and including units #304-Partial pass. 3. MEPS, metal drop ceiling locations-(only), rough combination inspection-partial approved. September 10, 2021: 1. No rough combination (MEPS)/building Deficiencies. 2. Assisted living building, section 9, third floor, up to and including units #304-Partial pass. 3. MEPS, metal drop ceiling locations-(only), rough combination inspection-partial approved. Passed Yes Yes Yes Yes Inspection 09/13/2021 BLDG-24 Rough/Topout 166377-2021 Partial Pass Tony Alvarado Reinspection Incomplete Tuesday, May 24, 2022 Page 21 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Status: Closed . Finaled Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Issue Date: 12/23/2020 Subdivision: Expiration Date: 09/27/2022 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 IVR Number: 23094 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Primary Inspector Reinspection Inspection Tuesday, May 24, 2022 Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency Status COMMENTS September 1, 2021: No exterior stucco metal lath-building Deficiencies. 1. Assisted living building, exterior south and west elevation (only), metal stucco wire lath-approved. September 10, 2021: No exterior stucco metal lath-building Deficiencies. 1. Assisted living building, exterior East elevation (only), metal stucco wire lath, all penetrations with silicone caulking, and metal weep screed installed, scope of work-partial approved. BLDG-84 Rough Combo(14,24,34,44) 166314-2021 Partial Pass Tony Alvarado Passed Yes Yes Reinspection Incomplete Page 20 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Issue Date: 12/23/2020 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Status: Scheduled Date 09/0712021 09/0812021 0911012021 Closed -Finaled Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector 09/07/2021 BLDG-17 Interior Lath/Drywall 165885-2021 Partial Pass Tony Alvarado 0910812021 09110/2021 Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS June 22, 2021: 1. No Building, insulation, drywall, floor nailing or MEPS Deficiencies. 2. Phase 4, first floor, corridor locations, final gypsum/drywall completed interior corridors-approved. 3. memory care building, section 3 & 4 second floor, sole plate and sub-floor plywood nailing pattern-approved. July 13, 2021: 1. No gypsum board/drywall Building Deficiencies. 2. Memory care building, phase B &C, first floor level, tub/ shower enclosures, preliminary-moisture resistive, (cement green board), scope of work; type, size, and method of attachment anchoring System-Approved. September 7, 2021: 1. Exterior metal, stucco, wire lath work-not ready, building Deficiencies-(not ready). 2. Assisted living building, section/phase-partial #9, 3rd. floor level, drywall/gypsum board, attachment schedule, per plan, for entire floor dwelling units #306 through #322 areas-Partial pass. 3. Assisted living building, phase 9 and 10, third floor level, energy-efficient thermal insulation, units #301 through #306 scope of work -partial pass. BLDG-22 Sewer/Water 166017-2021 Failed Tony Alvarado Service Checklist Item COMMENTS BLDG-Building Deficiency September 8, 2020: not ready BLDG-44 166016-2021 Failed Tony Alvarado Rough/Ducts/Dampers Checklist Item COMMENTS BLDG-Building Deficiency September 8, 2021: not ready BLDG-18 Exterior 166316-2021 Partial Pass Tony Alvarado Lath/Drywall Reinspection Inspection Reinspection Incomplete Passed Yes Yes Yes Reinspection Incomplete Passed No Reinspection Incomplete Passed No Reinspection Incomplete Tuesday, May 24, 2022 Page 19 of 50 PERMIT INSPECTIOl\a HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Issue Date: 12/23/2020 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Status: Scheduled Date 08/31/2021 0910112021 Closed -Finaled Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Checklist Item BLOG-Building Deficiency COMMENTS August 13, 2021: (No building/metal stud frame Deficiencies). 1. Memory care building, basement level, metal stud frame walls, top and bottom anchoring system, scope of work per structural engineer's plans and detail specifications-a pp roved. 08/31/2021 BLDG-17 Interior Lath/Drywall 165474-2021 Partial Pass Tim Kersch Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS June 22, 2021: 1. No Building, insulation, drywall, floor nailing or MEPS Deficiencies. 2. Phase 4, first floor, corridor locations, final gypsum/drywall completed interior corridors-approved. 3. memory care building, section 3 & 4 second floor, sole plate and sub-floor plywood nailing pattern-approved. June 14, 2021 · 1. No Building, insulation, drywall, floor nailing or MEPS Deficiencies. 2. Phase 4, first floor, corridor locations, final MEPS completed interior units-partial pass. 3. Phase 7, second floor, preliminary MEPS, interior units-partial pass. 4. Phase 3 & 4, first floor level, drywall nailing-(unit 101 through unit 111), excluding unit 11 o -partial pass. 5. memory care building, section 2, second floor, subfloor plywood nailing-partial pass. July 13, 2021: 1. No gypsum board/drywall Building Deficiencies. 2. Memory care building, phase B &C, first floor level, tub/ shower enclosures, preliminary-moisture resistive, (cement green board), scope of work; type, size, and method of attachment anchoring System-Approved. 09/01/2021 BLDG-18 Exterior Lath/Drywall 165709-2021 Partial Pass Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS September 1, 2021: No exterior stucco metal lath-building Deficiencies. 1. Assisted living building, exterior south and west elevation (only), metal stucco wire lath-approved. Reinspection Inspection Passed No Reinspection Incomplete Passed Yes Yes Yes Reinspection Incomplete Passed Yes Tuesday, May 24, 2022 Page 18 of 50 Permit Type: Work Class: Status: Scheduled Date 08/13/2021 PERMIT INSPECTION HISTORY for (CBC2019-0530) BLDG-Commercial Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC New Issue Date: 12/23/2020 Subdivision: Closed -Finaled Expiration Date: 09/27/2022 Address: 2540 FARADAY AVE IVR Number: 23094 CARLSBAD, CA 92008 Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Start Date Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency Status COMMENTS June 11, 2021: 1. No foundation/footing steel reinforcement Deficiencies. 2. Assisted living building, southside location of building, switchgear area, steel footing foundation reinforcement and epoxy Dowling to existing footing, per structural engineer's plans and detail specifications -approved. 3. Memory care building, northside location of building, building perimeter footing steel reinforcement, scope of work per structural engineer's plans and detail specifications-approved. May 19, 2021: 1. No Building Deficiencies. 2. Memory care building, pop out building footprint sections only, steel reinforcement rebar for slab on grade footings-approved. Deputy inspectors report received for rebar doweling/epoxied steel reinforcement rebar into existing slab and verifying type, size, steel reinforcement rebar and installation practices-approved. 3. Assisted living building, unit 112 111, 108 waste and vent lines-OK. 4. Section B, rough plumbing top out, waste and vent lines, under water leak pressure test: unit 110, 112, 1122-for all three levels/floors -approved. 5. Section D, first level areas-ceiling and walls-only, energy efficient type and size of insulation and gypsum board/drywall RC metal channel-approved. Passed Yes Yes Inspection BLDG-34 Rough Electrical 164002-2021 Partial Pass Tony Alvarado Reinspection Incomplete Checklist Item BLOG-Building Deficiency COMMENTS August 11, 2021. 1. Switchgear room, for memory care building, footings and UFER ground wire bonded and approved. 08/13/2021 BLDG-14 164170-2021 Passed Tony Alvarado Frame/Steel/Bolting/We lding (Decks) Passed Yes Complete Tuesday, May 24, 2022 Page 17 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Status: Scheduled Date 08/05/2021 08/06/2021 08/11/2021 Issue Date: 12/23/2020 Closed -Finaled Expiration Date: 09/27/2022 IVR Number: 23094 Subdivision: Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection 08/05/2021 BLDG-15 Roof/ReRoof 163643-2021 Passed Tony Alvarado Complete (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency July 28, 2021: Partial Pass. Yes 1. No exterior roof plywood sheathing nailing-Deficiencies. 2. Roof sheathing diaphragm system, sloped roof, flat roof and parapet roof walls,Plywood-type, size, and method of attachment anchoring System-Partial Approval. BLDG-Building Deficiency July 23, 2021: Partial Pass. Yes 1. No exterior roof plywood sheathing nailing-Deficiencies. 2. Roof sheathing diaphragm system, Plywood-type, size, and method of attachment anchoring System-Partial Approval. BLDG-Building Deficiency August 5, 2021: Yes 1. Roof plywood sheathing, For assisted Jiving building, elevator tower hip roof portions/sections-( only) . 2. Plywood; type, size, and plywood method of attachment anchoring system, per engineered plans and detail specifications-approved. 08/06/2021 BLDG-14 163707-2021 Partial Pass Tony Alvarado Reinspection Incomplete Frame/Steel/Bolting/We lding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency August 6, 2021: Yes 1. No dwelling units are drywall moisture resistive gypsum board Deficiencies. 2. Drywall/moisture resistive gypsum board, located in shower stalls, at dwelling unit bathroom areas; type, size, and method of attachment anchoring, scope of work-approved. 3. Memory care building, second floor, phase D & E, moisture resistive drywall-approved. 08/11/2021 BLDG-11 164003-2021 Partial Pass Tony Alvarado Reinspection Incomplete Foundation/Ftg/Piers (Rebar) Tuesday, May 24, 2022 Page 16 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Status: Closed -Finaled Application Date: 11/14/2019 Issue Date: 12/23/2020 Expiration Date: 09/27/2022 IVR Number: 23094 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS July 28, 2021: Partial Pass. 1. No exterior roof plywood sheathing nailing-Deficiencies. 2. Roof sheathing diaphragm system, sloped roof, flat roof and parapet roof walls.Plywood-type, size, and method of attachment anchoring System-Partial Approval. July 23, 2021: Partial Pass. 1. No exterior roof plywood sheathing nai I ing-Deficiencies. 2. Roof sheathing diaphragm system, Plywood-type, size, and method of attachment anchoring System-Partial Approval. 07/29/2021 07/29/2021 BLDG-13 Shear Panels/HD (ok to wrap) 163115-2021 Partial Pass Tony Alvarado Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency Tuesday, May 24, 2022 COMMENTS July 29, 2021: 1. No Final ceiling MEPS Building Deficiencies. 2. Final MEPS, 2-floor, in section 5 and section 6, assisted living building, ceiling lid above T-bar grid metal soffit location-approved. 3. Memory care building, second-floor locations, exterior shearwall; type, size, and method of attachment anchoring, per engineer plans and detail specifications-approved . 4. Deputy inspector report for exterior shearwall nailing, verified and filed-approved. June 30, 2021: 1. No Building Deficiencies. 2. Assisted living building, kitchen area, main grease ducting, kitchen area, smoke test-approved. 3. Assisted living building, first floor, production drywall nailing/anchoring - approved. 4. Memory care building, exterior shear wall nailing/anchoring-approved. July 9, 2021: Memory care building. 1. Building/shear-wall deficiencies (Not ready). 2. Sections: Exterior building sections, 1st. Floor level, exterior shear-wall; type, size, and nailing pattern, per structural engineers plans-Not ready, Not approved. Passed Yes Yes Reinspection Incomplete Passed Yes Yes No Page 15 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Issue Date: 12/23/2020 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Status: Scheduled Date 07/13/2021 07/23/2021 07/28/2021 Closed -Finaled Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector 07/13/2021 BLDG-17 Interior Lath/Drywall 161905-2021 Partial Pass Tony Alvarado Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS July 13, 2021: 1. No gypsum board/drywall Building Deficiencies. 2. Memory care building, phase B &C, first floor level, tub/ shower enclosures, preliminary-moisture resistive, (cement green board), scope of work; type, size, and method of attachment anchoring System-Approved. June 22, 2021: 1. No Building, insulation, drywall, floor nailing or MEPS Deficiencies. 2. Phase 4, first floor, corridor locations, final gypsum/drywall completed interior corridors-approved. 3. memory care building, section 3 & 4 second floor, sole plate and sub-floor plywood nailing pattern-approved. June 14, 2021: 1. No Building, insulation, drywall, floor nailing or MEPS Deficiencies. 2. Phase 4, first floor, corridor locations, final MEPS completed interior units-partial pass. 3. Phase 7, second floor, preliminary MEPS, interior units-partial pass. 4. Phase 3 & 4, first floor level, drywall nailing-(unit 101 through unit 111), excluding unit 110 -partial pass. 5. memory care building, section 2, second floor, subfloor plywood nailing-partial pass. 07/23/2021 BLDG-15 Roof/ReRoof {Patio) 162631-2021 Partial Pass Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS July 23, 2021: Partial Pass. 1. No exterior roof plywood sheathing nailing-Deficiencies. 2. Roof sheathing diaphragm system, Plywood-type, size, and method of attachment anchoring System-Partial Approval. 07/28/2021 BLDG-15 Roof/ReRoof (Patio) 162990-2021 Partial Pass Tony Alvarado Reinspection Inspection Reinspection Incomplete Passed Yes Yes Yes Reinspection Incomplete Passed Yes Reinspection Incomplete Tuesday, May 24, 2022 Page 14 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Issue Date: 12/23/2020 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Status: Scheduled Date 07/12/2021 Closed -Finaled Expiration Date: 09/27/2022 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 IVR Number: Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Checklist Item BLOG-Building Deficiency BLDG-Building Deficiency COMMENTS June 30, 2021: 1. No Building Deficiencies. 2. Assisted living building, kitchen area, main grease ducting, kitchen area, smoke test-approved. 3. Assisted living building, first floor, production drywall nailing/anchoring - approved. 4. Memory care building, exterior shear wall nailing/anchoring-approved. July 9, 2021: Memory care building. 1. Building/shear-wall deficiencies (Not ready). 2. Sections: Exterior building sections, 1st. Floor level, exterior shear-wall; type, size, and nailing pattern, per structural engineers plans-Not ready, Not approved. BLDG-16 Insulation Checklist Item 161580-2021 COMMENTS Partial Pass Tony Alvarado BLDG-Building Deficiency BLDG-Building Deficiency July 9, 2021: 1. No pre-liminary tub/shower-insulation installation Deficiencies. 2. First floor, memory care Building, Tub and shower bathroom dwelling unit locations, exterior wall, title 24 energy efficient-insulation installation: type, size, installation methods -approved. Canceled, wrong building. 07/12/2021 BLDG-16 Insulation Checklist Item 161689-2021 COMMENTS Failed Tony Alvarado BLDG-Building Deficiency BLDG-Building Deficiency July 12, 2021. Canceled/work not ready. 1. pre-liminary tub/shower-insulation installation Deficiencies. 2. First floor, memory care Building, Tub and shower bathroom dwelling unit locations, exterior wall, title 24 energy efficient-insulation installation: type, size, installation methods -Not completed or approved. July 9, 2021: 1. No pre-liminary tub/shower-insulation installation Deficiencies. 2. First floor, memory care Building, Tub and shower bathroom dwelling unit locations, exterior wall, title 24 energy efficient-insulation installation: type, size, installation methods -approved. Reinspection Inspection Passed Yes No Reinspection Incomplete Passed Yes No Relnspection Incomplete Passed No Yes Tuesday, May 24, 2022 Page 13 of 50 ' PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Issue Date: 12/23/2020 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Status: Scheduled Date 06/30/2021 07/07/2021 07/09/2021 Closed -Finaled Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS June 14, 2021: 1. No Building, insulation, drywall, floor nailing or MEPS Deficiencies. 2. Phase 4, first floor, corridor locations, final MEPS completed interior units-partial pass. 3. Phase 7, second floor, preliminary MEPS, interior units-partial pass. 4. Phase 3 & 4, first floor level, drywall nailing-(unit 101 through unit 111), excluding unit 11 0 -partial pass. 5. memory care building, section 2, second floor, subfloor plywood nailing-partial pass. June 22, 2021: 1. No Building, insulation, drywall, floor nailing or MEPS Deficiencies. 2. Phase 4, first floor, corridor locations, final gypsum/drywall completed interior corridors-approved. 3. memory care building, section 3 & 4 second floor, sole plate and sub-floor plywood nailing pattern-approved. 06/30/2021 BLDG-13 Shear Panels/HO (ok to wrap) 160825-2021 Partial Pass Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS June 30, 2021: 1. No Building Deficiencies. 2. Assisted living building, kitchen area, main grease ducting, kitchen area, smoke test-approved. 3. Assisted living building, first floor, production drywall nailing/anchoring - approved. 4. Memory care building, exterior shear wall nailing/anchoring-approved. 07/07/2021 BLDG-24 Rough/Topout 161249-2021 Partial Pass Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS July 7, 2021: 1. No Building Deficiencies. 2. Memory care building, first floor, basement level, rough plumbing top-out, waste and vent lines, under water leak pressure test-approved. 07/09/2021 BLDG-13 Shear Panels/HD (ok to wrap) 161585-2021 Failed Tony Alvarado Reinspection Inspection Passed Yes Yes Reinspection Incomplete Passed Yes Reinspection Incomplete Passed Yes Reinspection Incomplete Tuesday, May 24, 2022 Page 12 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Issue Date: 12/23/2020 Subdivision: Status: Scheduled Date 06/17/2021 06/22/2021 Closed -Finaled Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector 06/17/2021 BLDG-14 159907-2021 Partial Pass Tony Alvarado Frame/Steel/BoltinglWe lding (Decks) Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS June 8, 2021: 1. No assisted living building deficiencies. 2. Assisted living building, walls MEPS-rough frame inspection, unit 1 OD through 107, no corridors areas or common areas-approved. 4. Kitchen areas, dining room areas-preliminary ceilings, MEPS -rough frame inspection, and insulation -approved. 5. Phase 2, corridor and common areas, walls and ceiling, insulation inspection- Approved. 6. Scope of rough frame MEPS inspection, per structural engineer's plans and detail specifications-approved. 06/22/2021 BLDG-14 160420-2021 Partial Pass Tony Alvarado Frame/Steel/Bolting/We lding (Decks) Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS June 22, 2021: 1. No Building/sub-floor nailing Deficiencies. 3. memory care building, section 3 & 4 second floor, sole plate and sub-floor plywood-type, size and anchoring/nailing pattern-approved. June 8, 2021: 1. No assisted living building deficiencies. 2. Assisted living building, walls MEPS-rough frame inspection, unit 100 through 107, no corridors areas or common areas-approved. 4. Kitchen areas, dining room areas-preliminary ceilings, MEPS -rough frame inspection, and insulation -approved. 5. Phase 2, corridor and common areas, walls and ceiling, insulation inspection- Approved. 6. Scope of rough frame MEPS inspection, per structural engineer's plans and detail specifications-approved. BLDG-17 Interior Lath/Drywall 160248-2021 Partial Pass Tony Alvarado Reinspection Inspection Reinspection Incomplete Passed Yes Yes Reinspection Complete Passed Yes Yes Reinspection Incomplete Tuesday, May 24, 2022 Page 11 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Status: Closed -Finaled Application Date: 11/14/2019 Issue Date: 12/23/2020 Expiration Date: 09/27/2022 IVR Number: 23094 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS June 11, 2021: 1. No foundation/footing steel reinforcement Deficiencies. 2. Assisted living building, southside location of building, switchgear area, steel footing foundation reinforcement and epoxy Dowling to existing footing, per structural engineer's plans and detail specifications -approved. 3. Memory care building, northside location of building, building perimeter footing steel reinforcement, scope of work per structural engineer's plans and detail specifications-approved. May 19, 2021: 1. No Building Deficiencies. 2. Memory care building, pop out building footprint sections only, steel reinforcement rebar for slab on grade footings-approved. Deputy inspectors report received for rebar doweling/epoxied steel reinforcement rebar into existing slab and verifying type, size, steel reinforcement rebar and installation practices-approved. 3. Assisted living building, unit 112 111, 108 waste and vent lines-OK. 4. Section B, rough plumbing top out, waste and vent lines, under water leak pressure test: unit 110,112, 1122-forall three levels/floors -approved. 5. Section D, first level areas-ceiling and walls-only, energy efficient type and size of insulation and gypsum board/drywall RC metal channel-approved. 06/14/2021 06/14/2021 BLDG-17 Interior Lath/Drywall 159565-2021 Partial Pass Tony Alvarado Checklist Item BLDG-Building Deficiency Tuesday, May 24, 2022 COMMENTS June 14, 2021: 1. No Building, insulation, drywall, floor nailing or MEPS Deficiencies. 2. Phase 4, first floor, corridor locations, final MEPS completed interior units-partial pass. 3. Phase 7, second floor, preliminary MEPS, interior units-partial pass. 4. Phase 3 & 4, first floor level, drywall nailing-(unit 101 through unit 111), excluding unit 11 O -partial pass. 5. memory care building, section 2, second floor, subfloor plywood nailing-partial pass. Passed Yes Yes Reinspection Incomplete Passed Yes Page 10 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date Checklist Item Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Issue Date: 12/23/2020 Subdivision: Expiration Date: 09/27/2022 IVR Number: Inspection No. COMMENTS 23094 Inspection Status Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Primary Inspector Reinspection Inspection Passed BLDG-Building Deficiency June 8, 2021: Yes 06/1112021 06111/2021 BLDG-11 Tuesday, May 24, 2022 Foundation/Ftg/Piers (Robar) 1. No assisted living building deficiencies. 2. Assisted living building, walls ME PS-rough frame inspection, unit 100 through 107, no corridors areas or common areas-approved. 4. Kitchen areas, dining room areas-preliminary ceilings, MEPS -rough frame inspection, and insulation -approved. 5. Phase 2, corridor and common areas, walls and ceiling, insulation inspection- Approved. 6. Scope of rough frame MEPS inspection, per structural engineer's plans and detail specifications-approved . 159509-2021 Partial Pass Tony Alvarado Reinspection Incomplete Page 9 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Status: Closed -Finaled Application Date: 11/14/2019 Issue Date: 12/23/2020 Expiration Date: 09/27/2022 IVR Number: 23094 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLOG-Building Deficiency COMMENTS May 28, 2021 1. No Building Deficiencies. 2. Memory care building, pop-out building concrete slab footprint sections (only), vertical and horizontal steel reinforcement rebar for pored-place concrete walls-approved. Deputy inspectors report received for rebar doweling/epoxied steel reinforcement rebar at pored-place building sections and verified type, size, steel reinforcement. 3. Verified third-party deputy inspector report. rebar and installation practices-approved. May 19, 2021: 1. No Building Deficiencies. 2. Memory care building, pop out building footprint sections only, steel reinforcement rebar for slab on grade footings-approved. Deputy inspectors report received for rebar doweling/epoxied steel reinforcement rebar into existing slab and verifying type, size, steel reinforcement rebar and installation practices-approved. 3. Assisted living building, unit 112 111, 108 waste and vent lines-OK. 4. Section B, rough plumbing top out, waste and vent fines, under water leak pressure test: unit 110,112, 1122-forall three levels/floors -approved. 5. Section D, first level areas-ceiling and walls-only, energy efficient type and size of insulation and gypsum board/drywall RC metal channel-approved. 06/08/2021 06/08/2021 BLDG-14 159116-2021 Partial Pass Tony Alvarado Tuesday, May 24, 2022 Frame/Steel/Bolting/We lding (Decks} Passed Yes Yes Reinspection Incomplete Page 8 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date Checklist Item Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Issue Date: 12/23/2020 Expiration Date: 09/27/2022 IVR Number: Inspection No. COMMENTS 23094 Inspection Status Subdivision: Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Primary Inspector Reinspection Inspection Passed BLDG-Building Deficiency May 19, 2021: Yes BLDG-16 Insulation Checklist Item 1. No Building Deficiencies. 2. Memory care building, pop out building footprint sections only, steel reinforcement rebar for slab on grade footings-approved. Deputy inspectors report received for rebar doweling/epoxied steel reinforcement rebar into existing slab and verifying type, size, steel reinforcement rebar and installation practices-approved. 3. Assisted living buflding, unit 112 111, 108 waste and vent lines-OK. 4. Section B, rough plumbing top out, waste and vent lines, under water leak pressure test unit 11 O, 112, 1122 -for all three levels/floors -approved. 5. Section D, first level areas-ceiling and walls-only, energy efficient type and size of insulation and gypsum board/drywall RC metal channel-approved. 157816-2021 COMMENTS Cancelled Tony Alvarado BLDG-Building Deficiency Canceled, wrong building. 0512812021 05/2812021 BLDG-11 Tuesday, May 24, 2022 F ou n dation/Ftg/P iers (Rebar) 158448-2021 Partial Pass Tony Alvarado Reinspection Incomplete Passed No Reinspection Incomplete Page 7 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Status: Closed -Finaled Application Date: 11/14/2019 Issue Date: 12/23/2020 Expiration Date: 09/27/2022 IVR Number: 23094 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS May 5, 2021: No building/retaining wall steel deficiencies. 1. Memory Care Building, parking basement (driveway ramp section), basement parking level walls, steel reinforcement rebar for vertical and horizontal foundation steel rebar reinforcement-approved, Per structural engineers plans and detail specifications -approved. 2. Verified third party special/deputy inspector report. May 10, 2021: No building deficiencies. 1. Memory Care Building, basement section 2, podium-deck basement slab-steel reinforcement rebar, Per structural engineers plans and detail specifications - approved. 2. Verified and approved per deputy inspectors report. April 29, 2021: No building deficiencies. 1. Memory Care Building, parking basement driveway ramp section, basement parking level walls, steel reinforcement rebar for vertical and horizontal ramp walls-foundation steel rebar reinforcement-approved, Per structural engineers plans and detail specifications - approved. 2. Verified third party special/deputy inspector report. 05/19/2021 05/19/2021 BLDG-11 157691-2021 Partial Pass Tony Alvarado Tuesday, May 24, 2022 Foundation/Ftg/Piers (Rebar) Passed Yes Yes Yes Reinspection Incomplete Page 6 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Issue Date: 12/23/2020 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Status: Scheduled Date 05/05/2021 05/10/2021 Closed -Finaled Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection 05/05/2021 BLDG-11 156605-2021 Partial Pass Tony Alvarado Reinspection Incomplete Foundation/Ftg/Piers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency April 29, 2021 · Yes No building deficiencies. 1. Memory Care Building, parking basement driveway ramp section, basem~nt parking level walls, steel reinforcement rebar for vertical and horizontal ramp walls-foundation steel rebar reinforcement-approved, Per structural engineers plans and detail specifications - approved. 2. Verified third party special/deputy inspector report. BLDG-Building Deficiency March 25, 2021: Yes No building deficiencies. 1. Memory Care Building, basement section level, basement parking level walls, steel reinforcement rebar for vertical walls-steel reinforcement-approved, Per structural engineers plans and detail specifications - approved. 2. Verified third party special/deputy inspector report. BLDG-Building Deficiency May 5, 2021: Yes No building/retaining wall steel deficiencies. 1. Memory Care Building, parking basement (driveway ramp section), basement parking level walls, steel reinforcement rebar for vertical and horizontal foundation steel rebar reinforcement-approved, Per structural engineers plans and detail specifications-approved. 2. Verified third party special/deputy inspector report. 05/10/2021 BLDG-11 156868-2021 Passed Tony Alvarado Complete Foundation/Ftg/Piers (Rebar) Tuesday, May 24, 2022 Page 5 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Status: Closed -Finaled Application Date: 11/14/2019 Issue Date: 12/23/2020 Expiration Date: 09/27/2022 IVR Number: 23094 Owner: OAKMONT OF CARLSBAD LLC Subdivision: Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Reinspection Inspection Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS April 16, 2021: "No Building deficiencies". 1. Underground perforated drain pipe, in-set in gravel bed, wrapped in fiber-fabric moisture drain material-water plumbing lines for entire memory care poured-in-place concrete perimeter walls waterproofing drain system, per engineered plans and detail specifications-approved. 2. Entire memory care building poured-in-place concrete perimeter walls, verified installation of moisture resistive waterproofing mastic and moisture resistive foam board, per structural engineer plans and detail specifications-approved . February 5, 2021: "No Building deficiencies". 1. Underground trench domestic water plumbing lines for marketing building-approved. 2. Underground domestic water lines require thrust blocks, scope of installation of thrust blocks installed-approved. 04/29/2021 04/29/2021 BLDG-11 156205-2021 Partial Pass Tony Alvarado Tuesday, May 24, 2022 Foundation/Ftg/Piers (Rebar) Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS April 29, 2021: No building deficiencies. 1. Memory Care Building, parking basement driveway ramp section, basement parking level walls, steel reinforcement rebar for vertical and horizontal ramp walls-foundation steel rebar reinforcement-approved, Per structural engineers plans and detail specifications - approved. 2. Verified third party special/deputy inspector report. March 25, 2021: No building deficiencies. 1. Memory Care Building, basement section level, basement parking level walls, steel reinforcement rebar for vertical walls-steel reinforcement-approved, Per structural engineers plans and detail specifications - approved. 2. Verified third party special/deputy inspector report. Passed Yes Yes Reinspection Incomplete Passed Yes Yes Page 4 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Work Class: New Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date Checklist Item Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Issue Date: 12/23/2020 Subdivision: Expiration Date: 09/27/2022 IVR Number: Inspection No. COMMENTS 23094 Inspection Status Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Primary Inspector Reinspection Inspection Passed BLDG-Building Deficiency March 8, 2021: Yes 03/2512021 03125/2021 BLDG-11 F ou n datio n/Ftg/Piers (Rebar) Checklist Item No building deficiencies. 1. Memory Care Buildlng, basement section 1, basement parking level slab-steel reinforcement rebar for slab foundation steel reinforcement columns deck piers- approved, Per structural engineers plans and detail specifications -approved. 2. Verified special/deputy inspector report. 153531-2021 Partial Pass Tony Alvarado COMMENTS BLDG-Building Deficiency March 25, 2021: 04/21/2021 04116/2021 BLDG-21 Tuesday, May 24, 2022 Underground/LI nderflo or Plumbing No building deficiencies. 1. Memory Care Building, basement section level, basement parking level walls, steel reinforcement rebar for vertical walls-steel reinforcement-approved, Per structural engineers plans and detail specifications - approved. 2. Verified third party special/deputy inspector report. 155118-2021 Partial Pass Tim Kersch Reinspection Incomplete Passed Yes Reinspection Incomplete Page 3 of 50 PERMIT INSPECTION HISTORY for (CBC2019-0530} Permit Type: BLDG-Commercial Work Class: New Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Issue Date: 12/23/2020 Subdivision: Status: Scheduled Date 03/05/2021 03/08/2021 Closed -Finaled Expiration Date: 09/27/2022 IVR Number: 23094 Address: 2540 FARADAY AVE CARLSBAD, CA 92008 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS February 19, 2021: No building deficiencies. 1. Memory Care Building, basement section 1, basement slab-steel reinforcement rebar, Per structural engineers plans and detail specifications -approved. March 1, 2021: No building deficiencies. 1. Memory Care Building, basement section 2, basement slab-steel reinforcement rebar, Per structural engineers plans and detail specifications -approved. 2. Verified and approved per deputy inspectors report. 03/05/2021 BLDG-11 152026-2021 Passed Tony Alvarado F ou n datio n/Ftg/P iers (Rebar) Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS March 5, 2021: No building deficiencies. 1. Memory Care Building, basement section 1, basement slab-steel reinforcement rebar for slab foundation steel reinforcement columns piers-approved, Per structural engineers plans and detail specifications - approved. 2. Verified special/deputy inspector report. February 19, 2021: No building deficiencies. 1. Memory Care Building, basement section 1, basement slab-steel reinforcement rebar, Per structural engineers plans and detail specifications -approved. March 1, 2021: No building deficiencies. 1. Memory Care Building, basement section 2, basement slab-steel reinforcement rebar, Per structural engineers plans and detail specifications -approved. 2. Verified and approved per deputy inspectors report. 03/08/2021 BLDG-12 Steel/Bond Beam 152267-2021 Partial Pass Tony Alvarado Reinspection Inspection Passed Yes Yes Complete Passed Yes Yes Yes Reinspection Incomplete Tuesday, May 24, 2022 Pago 2 of 50 Building Permit Inspection History Finaled (city of Carlsbad PERMIT INSPECTION HISTORY for (CBC2019-0530) Permit Type: BLDG-Commercial Application Date: 11/14/2019 Owner: OAKMONT OF CARLSBAD LLC Work Class: New Issue Date: 12/23/2020 Subdivision: Status: Closed -Finaled Expiration Date: 09/27/2022 Address: 2540 FARADAY AVE IVR Number: 23094 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 01/20/2021 01/20/2021 BLOG-12 Steel!Bond 148629-2021 Partial Pass Tim Kersch Re inspection Incomplete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 02/05/2021 02/05/2021 BLDG-21 149902-2021 Partial Pass Tony Alvarado Reinspection Incomplete Underground/Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency February 5, 2021: Yes "No Building deficiencies". 1. Underground trench domestic water plumbing lines for marketing building-approved. 2. Underground domestic water lines require thrust blocks, scope of installation of thrust blocks installed-approved. 02/19/2021 02/19/2021 BLDG-11 150896-2021 Partial Pass Tony Alvarado Reinspection Incomplete Foundation/Ftg/Piers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency February 19, 2021: Yes No building deficiencies. 1. Memory Care Building, basement section 1, basement slab-steel reinforcement rebar, Per structural engineers plans and detail specifications -approved. 03/01/2021 03/01/2021 BLDG-11 151583-2021 Partial Pass Tony Alvarado Reinspection Incomplete F ou n dation/Ftg/P iers (Rebar) Tuesday, May 24, 2022 Page 1 of 50 CCityof Carlsbad SPECIAL INSPECTION AGREEMENT B-45 Develo ment Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov In accordance with Chapter 17 of the Callfomla Building Code the following must omp eti en work being performed requires special Inspection, structural observation and construction material testing. ~~I q..-- Project/Permit: P.C2DHI 'ilQ69 D "::,?:;o Project Address: 2540 ~ Faraday Ave., Carlsbad CA A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you are Owner-Builder □. (If you checked as owner-builder you must also complete Section B of this agreement.) Name: (Please prtnt,1--) ____ D_a_v_id __________ N_. __________ S_a_ns_o_tt_a _____ _ (Finl) (M.I.) (last) Mailing Address· Structural Edge Engineering, 5509 N Glenwood St., Boise, ID 83714 Email· davids@structuraledge.com Phone: 208-501 -2289 I am: □Property Owner □Property Owner's Agent of Record □Architect of Record Ji(Engineer of Record State of California Registration Numbe · C-771 07 Expiration Date:_1_2/_2_0_20 ____ _ AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read, understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of special inspections noted on the approved I ns and, as required by the California Building Code. Signature· ~t, ft"''!-Date: _7_/2_5_/2--'0_1..::...9 ______ _ B. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor I builder / owner-builder. Contractor's Company Name:.__cO:..S:..L:..C..::...o.::..:nc..::s..::...tru-=.ct.::..::..:io-'--n-"lnc..::c:..:.... ___________ Please check if you are Owner-Builder □ Name: (Please prtnt) __ __;D:;.;a;;:..;v..:..;id:...;Hc..:.u::..:n=te:;.;.r ___________________________ _ (First) (M.I.) (Last) Mailing Address: 9240 Old Redwood Hwy. Suite 200, Windsor, CA 95492 Email: _ __,D!e<!a...,y"'id...._,H,__,_u..,n_...te,.,.,r.,..@,..,o.,.awk,..m,,.ownt.,.sl,.,_,.co=m,_ ____________ Phone: 707-535-321 3 State of California Contractor's License Number:.~a ..... 06~3 ... 65......_ ______ Expiration Date: ....... 4 ... L3 ... a .... 12 ... o.__ ___ _ • I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; • I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; • I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and the distribution of the reports; and • I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. • I w/11 provide a final report I letter In compliance with CBC Section 1104.1.2 prior to requesting final Inspection') A'}/ L_ Signature: ~~ ~ Date: -~J=u,.,_ly...,2""5..,. 2...,0....,1=9 _____ _ B-45 Page 1 of 1 Rev. 08/11 I Ba&M»aa -- • '-"' mvwn. DATE: June 15, 2020 JURISDICTION: Carlsbad ✓• EsG1I A SAFfhu1lt Conip;,ny PLAN CHECK#.: CBC2019-0530 PROJECT ADDRESS: 2540 Faraday Ave. SET: IV PROJECT NAME: Oakmont of Carlsbad: Memory Care Building iAPPLICANT r JURIS D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. ~ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: Byron Hills ~ EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted : ~yron Hills Telephone#: 208-258-6154 Date contacted: b/li.j](b yW'l) Email: BHills@BHillsArch.com Mail Telephone Fax In Person A}t__, ~ REMARKS: #1). Please correct the l?J?n scales for Sheets M 1 .1-M3.3 & Sheets P 1.1-P3.1 for the sets at the City (i.e. the x1 set sent to EsGil was redlined at EsGil). The given scale states ¼" = 1' O", yet the scale should be 1/8" = 1'-0". m No electrical sheets were provided within set IV. Please slip sheet set II V ~ electrical sheets into set IV. m he structural sheet index on the title sheet is missing several sheets. Please add the mi~g sheet to the index for the sets at the City (i.e . the x1 set sent to EsGil was redlined at EsGil). ~~ By: ALI SADRE, S.E. (for K.C.) EsGil 6/9/20 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, Cali forn ia 92 123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 DATE: MAY 08, 2020 JURISDICTION: Carlsbad ✓• EsG1I A SAFFbuitt-Cornpany PLAN CHECK#.: CBC2019-0530 PROJECT ADDRESS: 2540 Faraday Ave. SET: III PROJECT NAME: Oakmont of Carlsbad: Memory Care Building □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Byron Hills D EsGil staff did not advise the applicant that the plan check has been completed. ~ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Byron Hills Telephone#: 208-258-6154 Date contacted: (by: Email: BHills@BHillsArch.com Mail Telephone Fax In Person ~ REMARKS: Please note that slip sheeting will be required to be done at the City by the applicant. By: ALI SADRE, S.E. (for K.C.) EsGil 4/24 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBC2019-0530 MAYOS, 2020 GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring r1'!KJ. corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. PLUMBING AND MECHANICAL COMMENTS PLAN REVIEWER: Connor Reuss SET: Ill NOTE: Please address all bolded plumbing and mechanical comments below. PLUMBING (2016 CALIFORNIA PLUMBING CODE) 2. The California Energy Code requirements must be factored in. The most restrictive code must be upheld at all times, as follows: ½" pipe (½" insulation); ¾" pipe (1" insulation); 1 "-1 ½" pipes (1 ½" insulation); 2" pipes are larger (2" insulation). CPC 609.11 & ES 150.0U) II Plans state that all insulation will be 1". Please correct to comply with the following:½" pipe(½" insulation); ¾" pipe (1" insulation); 1"-1 ½" pipes (1 ½" insulation); 2" pipes are larger (2" insulation). CPC 609. 11 & ES 150. OU) MECHANICAL (2016 CALIFORNIA MECHANICAL CODE) 3. There are x4 exhaust fans from the restrooms adjacent to the 1st Senior Common Area (i.e. room with fireplace) that are found with 2x4 walls in the 2nd floor. Please correct. II The plans show circular 5" & 6" circular exhaust ducts within 2"x4" walls (actual size 1.5"x3.5']. These ducts will not fit into the walls. Please correct the design. 4. Please address the bolded comments below regarding the sleep unit bathroom exhaust fans (that penetrate up through the roof): • Sleeping unit exhaust fans are shown within 1 O' of SF-1 and SF-3 within the mechanical roof plan. Per CMC 502.2.1, a minimum 10' clearance must be maintained. Please correct the design accordingly. II The mechanical floor plans do NOT show the routing of any of the sleeping unit exhaust fans. Please clearly show the routing and shaft protection for each bathroom exhaust fan up through the roof. Carlsbad CBC2019-0530 MAY 08, 2020 • Please correct the 'Location' row for the EF-1 on sheet M0.2 (i.e. it states Dining room, yet EF-1 is found within the sleeping units). II Clearly specify the sleep unit bathroom exhaust fans within the exhaust schedule. • To be able to use the exception in CBC 717.6.1, the 4" exhaust fans must be within a wall cavity through the attic space up to the bottom of the roof sheathing. Please provide a detail showing this. II Clearly specify the proposed method (per CBC Chapter 7) that will be used for each bathroom exhaust duct penetration so fire rating of the floor ceiling assembly will be properly maintained. NO TE: More comments may follow when a method is shown within the plans. 5. Sheet M2.2 still shows a duct penetrating exit stairway #3. Please correct upon next submittal. II Sheet M2.2 still shows a duct penetrate through the exit stairway (i.e. stair #3). Please correct the design to comply. I Duct work cannot penetrate exit stairways. Please correct sheet M2.2. CBC 1023.5 6. The plans on sheet M1 .1, x1 of the x3 basement exhaust fans is shown within a 2x4 wall (i.e. the other x2 fans are shown in the proper 2x8 wall). Please correct. II These x3 basement bathroom exhaust fans are now: (1) shewn f)enelratinq a fire ralee assemla.'y wilheut Ille f)Fef)er eamf)erweleslien and (2) shown as 5" & 6" circular exhaust ducts yet within 2"x4" walls (actual size 1.5"x3.5"). These ducts will not fit into the wall. Please address both issues. II The mechanical plans show ducts that extend from the basement level to the roof without any shaft protection. Please correct. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Connor Reuss at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. DATE: FEB.26,2020 JURISDICTION: Carlsbad PLAN CHECK#.: CBC2019-0530 ✓• EsG1I A SA!·Fth1i!t'Cor1,par1y SET: II PROJECT ADDRESS: 2540 Faraday Ave. PROJECT NAME: Oakmont of Carlsbad: Memory Care Building 0 APPLICANT 0 JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [8J The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. PLEASE SEE BELOW D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [8J The applicant's copy of the check list has been sent to: Byron Hills D EsGil staff did not advise the applicant that the plan check has been completed. [8J EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Byron Hills Telephone#: 208-258-6154 Date contacted: (by: ) Email: BHills@BHillsArch.com Mail Telephone Fax In Person [8J REMARKS: Please see attached for remaining corrections from previous list. By: ALI SADRE, S.E. (for K.C.) EsGil 2/06 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBC2019-0530 FEB.26,2020 GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. PLANS 2. As per response list, detail R/A1 .2B shows the designated van accessible parking; however, the access aisle is still located on the wrong side. Section 1109A.8.6. ADDITIONAL 3. Please see below for any remaining P/M/E corrections. 4. Electrical is approved as is. 5. To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 6. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact ALI SADRE, S.E. at EsGil. Thank you. PLUMBING AND MECHANICAL COMMENTS PLAN REVIEWER: Connor Reuss SET: II NOTE: Please address all bolded plumbing and mechanical comments below. PLUMBING (2016 CALIFORNIA PLUMBING CODE) 7. Clearly specify which materials will be used (do not just give a list of approved materials). Carlsbad CBC2019-0530 FEB.26,2020 8. If PVC or ABS will be used for waste and vent, clearly specify it will be schedule 40 within the plans. 9. If PVC or ABS will be used for waste and vent, provide manufacturer's firestop details to the plumbing plans. Make sure the provided details are (1) listed, (2) approved for the proposed material, (3) approved for the proposed size of pipe and (4) has a T & F rating not less than 1-hr. 10. Bathroom groups are not within CPC Appendix A. The plans are still done per CPC Appendix C. Provide documentation from the Building Official allowing the use of CPC Appendix C or size per Appendix A (i.e. per fixture). I Please either provide approval from the Building Official allowing the use of CPC Appendix C (i. e CPC page XVI: "Alternative methods are allowed to be used where approved by the authority having jurisdiction.") for sizing the water lines or provide water sizing calculations per CPC 610.0 or Appendix 'A'. Note: A complete review of the water system will be conducted upon addressing this comment. 11. Bathroom groups are not within CPC Chapter. The plans are still done per CPC Appendix C. Provide documentation from the Building Official allowing the use of CPC Appendix C or size per Chapter 7 (i.e. per fixture). I Please either provide approval from the Building Official allowing the use of CPC Appendix C (i.e CPC page XVI: "Alternative methods are allowed to be used where approved by the authority having jurisdiction.") for sizing the waste lines or provide waste sizing calculations CPC Table 702.1 & Table 703.2. Note: A complete review of the waste system will be conducted upon addressing this comment. 12. Please correct the notes on sheet P1 .0. The 8'2" clearance is required from the the entrance of the parking structure to the handicap space (not just above the handicap space). I Within the plumbing plans, clearly specify the minimum overhead clearances that must be maintained in the garage on the plumbing plans. Identify the handicap accessible (8'2" minimum) clearances and for areas that are not handicap accessible identity a 7'0" clearance. Note: The 8'2" clearance is required to extend from the handicap parking spaces to the entrance of the parking garage (not just above the handicap parking spaces). 13. Please show the routing of all subsoil drains. Specify the material. Provide a detail to the plumbing plans that comply with CPC 1101.6 & 1101.4.6. I The plumbing plans do not mention any subsoil drains. Please review CPC Section 1101 and provide the provide subsoil drainage. 14. It appears detail C on sheet A7.1 is not 'readily visible' (i.e. tucked underneath the roof overhang). Please address. I Per City of Carlsbad, overflow roof drains shall terminate in an area where they will be readily visible and will not cause damage to the building. If the roof drain terminates through a wall, the overflow drain shall terminate 12" minimum above the roof drain. Policy 84-35. 15. Plans state that all insulation will be 1 ". Please correct to comply with the following: ½"pipe(½" insulation); ¾" pipe (1" insulation), 1"-1 ½" pipes (1 ½" insulation); 2" pipes are larger (2" insulation) CPC 609.11 & ES 150.0(j) Carlsbad CBC2019-0530 FEB.26,2020 16. The shutoff valves should be for each unit. Several risers have x2 units. For all risers that have x2 units, please provide shut-off valves for each unit. I Each dwelling unit in a multifamily building shall have the ability for shut-off of the water supply for the unit in the unit itself Detail how this is accomplished, either by unit full way valves or by individual fixture shut-offs (include fixture stop style for bath/showers). CPC 606.3 17. Specify where the water stations will be positioned within sheet P1 .1. I Drinking fountains are required by CPC Table 422. 1 for this occupancy type (if the occupant load exceeds 30. CPC 415.2). Review the requirements of/his Table and provide as necessary. Note: If food is consumed indoors, water stations may be substituted for drinking fountains. CPC 415.2 18. Specify the manufacturers required anchorage and structural foundation for the industrial clothes wsher within the plumbing plans. I Please show the commercial clothes washer (commercial dryer specified within mechanical plans) on the plumbing plans. Make sure the required water supply line, waste supply line, structural foundation, and anchorage is specified. 19. It appears the floor sinks used for P& T discharge for WH-1, WH-2 and WH-3 will be used infrequently. If so, please provide trap primer connections. I For WH-3, show P & T valve on water heater and detail the drain routing to the exterior or approved location. ft may not be installed upwards from the valve. CPC 608.5 20. Please address the bolded comments below: I For the gas riser on sheet P6.0, please address the following: • The gas routing with the riser on sheet P6.0 is incomplete. Clearly show the routing to each individual appliance. I Show the gas line routing to all appliances (i.e. W-1 & WH-2, each dryer etc.) • The laundry room (1 st and 2nd floor) show an additional¾" line connection that is not within the riser diagram on sheet P6.0. Clearly specify what this is connecting to. Specify the CFH value of this appliance within the plans. I Specify the size of all newly shown gas lines. • Specify the CPC Table 1216.2(1) & 1216.2(4) on sheet P6.0. I Please specify the CPC Table used to size the low pressure and medium pressure lines on sheet P6.0. MECHANICAL (2016 CALIFORNIA MECHANICAL CODE) 21. For the 1"1 floor fireplace, clearly show: (1) the vent routing within the mechanical plans, (2) how the fire rated horizontal floor ceiling assemblies/rated wall assemblies will be maintained and (3) the termination location. 22. Please address the following comments regarding the kitchen area: • Sheet M0.2 still shows MAU units and a kitchen pressurization table. Please remove upon next submittal. I Sheet M0.2 specifies x3 kitchen grease exhaust hoods and make-up air units yet no kitchen grease hoods are shown within the mechanical plans. Please address. Carlsbad CBC2019-0530 FEB.26,2020 • Clearly specify what type of cooking equipment will be installed within the serving areas. Depending on the type of cooking equipment, a type I hood may be required. NOTE: If a type I hood is required, more comments will follow. • If a type I hood is not required, please state within the mechanical plans the manufacture, model, CFM and all other necessary information regarding the residential hood exhaust fan. 23. The plans show circular 5" & 6" circular exhaust ducts within 2"x4" walls (actual size 1.5"x3.5"). These ducts will not fit into the walls. Please correct the design. 24. Since each building is proposed to be type VA construction, the fire rating construction around the 2nd floor exhaust ducts must extend through any attic space to the bottom of the roof sheathing. 25. Please address the following bullet points below regarding the sleep unit bathroom exhaust fans (that penetrate up through the roof): • The mechanical floor plans do NOT show the routing of any of the sleeping unit exhaust fans. Please clearly show the routing and shaft protection for each bathroom exhaust fan up through the roof. • Clearly specify the sleep unit bathroom exhaust fans within the exhaust schedule. • Provide ID tags for all sleeping unit bathroom exhausts. • Clearly specify the proposed method (per CBC Chapter 7) that will be used for each bathroom exhaust duct penetration so fire rating of the floor ceiling assembly will be properly maintained. NOTE: More comments may follow when a method is shown within the plans. • This requirement is required for the sleeping unit bathroom exhaust fans. This comment will be addressed when more information regarding the sleeping unit exhaust fans are provided. I All exhaust systems in residential bathrooms that are not used for whole house ventilation requires a humidistat. Please address Ca/Green 4. 506 26. Specify what mechanical sheet the calculations can be found. I For CU-1, CU-2, CU- 3 and CU-4 (provide sperate calculations for each), please provide calculations that show compliance with CMG 1104. 2 "Refrigerant Concentration Limit" for the worst-case concentration/area scenario (i.e. please see CMG Table 1102.2 for allowable quantities). 27. Please address the following comments regarding the shaft behind the laundry room: • The exhaust duct routing for EF-3, the residential and commercial dryers within the shaft (behind the laundry room) is inconsistent between the 2nd floor and the roof plan termination locations. Please correct the plans to show consistency between the plans. • Please provide a combination fire smoke damper to the EF-3 shaft penetration to the 2nd floor shaft (behind the laundry room) on sheet P2.2. Carlsbad CBC2019-0530 FEB.26,2020 • Each dyer (residential and commercial) within the 1st and 2nd floor will require fire stopping at each penetration of the fire rated shaft. Please specify this within the plans. Provide fire stopping details to the mechanical plans. 28. Please address the following comments regarding the shaft adjacent to Room AAZ- 35W: • EF-5 is not shown within the shaft on the 1st and 2nd floor mechanical plans. Please correct. • Please provide combination fire smoke dampers to the penetrations of EF-5 and SF-3 of the shaft penetration on the 2nd floor. • It appears the locations of EF-5 and SF-1 are within 10' of each other shown on the 2nd floor penetrations up through the roof (yet have the 16' clearance within the roof plan). Please address. 29. It appears GR-1 is shown to be a forced air inlet. Therefore, a 10' clearance is required from all exhaust terminations. Sheet M3.3 shows a bathroom exhaust termination within 2' of GR-1. Please correct. 30. Sheet M2.2 still shows a duct penetrate through the exit stairway (i.e. stair #3). Please correct the design to comply. I Duct work cannot penetrate exit stairways. Please correct sheet M2.2. CBC 1023.5 31. These x3 basement bathroom exhaust fans are now: (1) shown penetrating a fire rated assembly without the proper damper protection and (2) shown as 5" & 6" circular exhaust ducts yet within 2"x4" walls (actual size 1.5"x3.5"). These ducts will not fit into the wall. Please address both issues. I The mechanical plans show ducts that extend from the basement level to the roof without any shaft protection. Please correct. 32. The area outside air rate shown on sheet M0.3 is incorrect. Please see Energy Standards Table 4-14 (i.e. offices require 0.15 cfm/sq.ft; lobbies require 0.50 cfm/sq.ft; lounges required 0.50 cfm/sq.ft. etc.) I The outside air rates shown within the schedule on sheet M0.3 is incorrect per California Energy Standards. Please see right hand column of Table 4-14 for the proper rates. Please upsize accordingly. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Connor Reuss at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. 01/20/2020 Mr. Mark Rossiter Oakmont Senior living 9240 Old Redwood Highway Ste. 200 Windsor, CA 9S492 RE: 1 sr Building Plan Review Correction List Response Plan Check #CBC2019-0530 Oakmont of Carlsbad Memory Care Mark, 0202 t O 83.:1 The following are the responses to the EsGil Plan Review Correction List dated December 09, 2019 for the Oakmont of Carlsbad Memory Care project. All revisions have been clouded on the resubmitted drawings. CORRECTIONS 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, {760/ 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, {858/ 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. PLANS 2. All sheets of the plans are required to be signed by the licensed architect or engineer responsible for the plan preparation. California State Law. RESPONSE: Noted 3. Please provide the grading plans (civils} so that site slopes can be verified for disabled access compliance. RESPONSE: Grading plans have provided b . h i I I s a r c h i I e c t u r e , P C 3 1 5 6 s o u I h b o w n w a y b o i s e i d a h o [ 8 3 1 0 2 [ p . 2 0 8 . 2 5 8 6 1 5 0 [ w w w b h i I I s a r c h c om Building Plan Review Response Letter Oakmont Senior Living (Memory Care) Carlsbad, CA Page 2 of 11 4. Revise the exit sign locations on the electrical plans at Room 1111 so that the sign is at the swinging door (not at the bi-fold door). RESPONSE: See revised sheet E2.1. 5. In each story of a mixed occupancy building, the maximum number of occupants served by a single exit shall be such that the sum of the ratios of the calculated number of occupants of the space divided by the allowable number of occupants for each occupancy does not exceed one. Section 1006.3.2.1. a) Although the garage occupants have access to 2 exits, occupants in Rooms G114/107/108 only have access to 1 exit. Per Section 1006.3.2.1, it appears that 2 exits must be provided (and passing through the garage is not permitted). RESPONSE: See revised sheet Al.S. The ratio calculation has been added to reflect the occupants that use the exit stairway. The ratio is less than (11 one and the total occupant load is 24 which only requires a single exit. 6. At A/ A4.3, please clarify the construction of the curved wall behind the row of seats. Since this portion of the building is Type I Construction, wood studs are not allowed. RESPONSE: See revised sheet AZ.l. A wall type callout has been added to clarify the type of construction. It is a steel stud wall. Sheet Al.l has the schedule of the wall types. 7. One in every eight accessible spaces, but not less than one, shall be served by an access aisle 8' wide minimum and shall be designated van accessible with a sign "Van Accessible" mounted below the symbol of accessibility. Alternately, the parking space may be 12' wide with the access aisle 5' wide. Section 1109A.8.6. The access aisle shall be located on the passenger side of the vehicle. SHEET A2.1 SHOWS IT ON THE WRONG SIDE. RESPONSE: See sheets Al.ZA and Al.ZB detail 'S' for the Van Accessible parking space. The parking space shown on the AZ.l is not the Van Accessible space. 8. Exit doors shall swing in the direction of exit travel when serving a room containing an occupant load of 50 or more persons or a Group H occupancy. Section 1010.1.2.1. a) Since the room (garage) has more than 49 people, Door G116 must swing the other way. b) Doors 1220 and 1221 must swing the other way. RESPONSE: Door Gll6 has been revised to swing in the direction of exit travel. See revised sheet A2.1. Door 1122C only has an occupant load of 24 thus the swing of the door is not required to swing in the direction of exit travel. Door 1121 has been revised to swing in the direction of exit travel. See revised sheet A2.Z. 9. Each door in a means of egress from an occupancy of Group A having an occupant load of 50 or more shall not be provided with a latch or lock unless it is panic hardware. Section 1010.1.10. a) Door 1114. RESPONSE: Door 1114 has had the hardware group added to it which contains panic hardware. See revised sheet AS. l. b . h i I I s architecture, PC 3156 south bown way b a i s e i d ah a I 8 3 l O 2 I p . 2 0 8 . 2 5 8 . 6 1 5 0 I ww w . b h i I I s arch . ca rn Building Plan Review Response Letter Oakmont Senior Living (Memory Care) Carlsbad, CA Page 3 of 11 10. In R-1, R-2 and R-3 occupancies, where window openings are >72" above grade, then the lowest part of the window opening shall be at least 36" above the floor. Section 1015.8. RESPONSE: See Window note #6 on sheet AS.1 for the window opening control device. STRUCTURAL 11. Provide a copy of the project soil report prepared by a licensed civil engineer. The report shall include foundation design recommendations based on the engineer's findings. RESPONSE: See attached Updated Geotechnical Report dated May 20. 2019. 12. In Seismic Design Categories D, E or F, the soils investigation must address liquefaction, and, if retaining walls are proposed, the soils investigation must address increased loading on the walls due to earthquake motions. Section 1803.5.12. RESPONSE: See attached Updated Geotechnical Report dated May 20. 2019. 13. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soil report are properly incorporated into the plans (when required by the soil report). RESPONSE: See attached Letter from Geotech dated September 20. 2019. 14. Carlsbad requires that their unique Special Inspection Program (available on their website) be completed, signed and returned. RESPONSE: See attached Special Inspection Agreement. ADDITIONAL 15. Please see below for MEP corrections. RESPONSE: Noted 16. To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. RESPONSE: Noted 17. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. RESPONSE: Changes have been made to the A0.1. E0.1. Al.3. A2.2. A2.3 and A2.3 for comments from the Fire Plan review. Those changes are clouded on this set also. Have changes been made to the plans not resulting from this correction list? Please indicate: □Yes X No b h i I I s a r c h i t e c t LI r e . P [ 3 1 5 6 s o LI t h b o w n w a y b a i s e i d ah o \ 83102 \ p 208.258.6150 \ www.bhillsarch.com Building Plan Review Response Letter Oakmont Senior living (Memory Care) Carlsbad, CA Page 4 of 11 18. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Kurt Culver, S.E. at Esgi/ Corporation. Thank you. RESPONSE: Noted PLUMBING AND MECHANICAL COMMENTS GENERAL P&M ITEMS 1. Pleas provide the fireplace manufacturer's installation instructions. Make sure the required clearances are specified. RESPONSE: See attached manufacture installation manual. 2. Please clearly specify all fire rated assemblies and review with the mechanical designer to ensure all HVAC penetrations are equipped with the proper fire protection. RESPONSE: Fire assembly schedule is on sheet Al.1 and are called out on sheets A2.1-A2.3. See sheet A7.7 for damper detail. 3. Keynote #30 on sheet A4.2 and A4.3 state the sleeping unit HVAC units will be within the attic. Access is required to be no smaller than the largest component of the appliance, yet not less than 22" by 30". Please address. RESPONSE: Keyed note 30 has been revised. See revised sheets A4.1 and A4.2. The Fan Coil units do not set inside the attic space. There is a ceiling that is dropped below the fire assembly and the Fan Coil is mounted in that area. PLUMBING (2016 CALIFORNIA PLUMBING CODE} 4. Provide a plumbing material schedule on the plans describing the following systems: Potable water piping, the drain, waste, and vent piping, gas piping, and the roof drains. Note: In addition, please address the following bullet points. • In areas of residential accommodation drainage piping material /i.e. waste, vent and storm drainage) types ABS and PVC are limited to buildings of two stories or less. All buildings that have 3 or more levels of residential units cannot use PVC or ABS. Please address. CPC 701.2/a), CPC 903.1.1, & CPC 1101.4 • A Certification of Compliance is necessary when installing CPVC/PEX water piping materials prior to building permit issuance. CPC 604.1.1 {CPVC)/CPC 604.1.2/PEX) Note: Please specify this within the material schedule. RESPONSE: Piping material specifications are shown on the sheet P0.1. • This is a two story building and comply. • Certification requirements are shown on sheet P0.1. b . h i I I s architecture, PC 3156 south bown way b o i s e i d ah o I 83102 Ip. 208.258.6150 111111.bhillsarch.com Building Plan Review Response Letter Oakmont Senior living {Memory Care) Carlsbad, CA Page Sol 11 5. For backwater valve review, please show the upstream sewer manhole rim ond finished floor elevations. CPC 710.0 • Mandatory: Fixtures installed on o floor level below the next upstream manhole cover require backwater protection. RESPONSE: There are no fixtures installed below the manhole cover. 6. Please either provide approval from the Building Official allowing the use of CPC Appendix C (i.e CPC page XVI: "Alternative methods are allowed to be used where approved by the authority having jurisdiction.") for sizing the water lines or provide water sizing calculations per CPC 610.0 or Appendix 'A'. Note: A complete review of the water system will be conducted upon addressing this comment. RESPONSE: Calculation is revised. See revised sheet P0.2. 7. Please either provide approval from the Building Official allowing the use of CPC Appendix C (i.e CPC page XVI: • Alternative methods are allowed to be used where approved by the authority having jurisdiction.") for sizing the waste lines or provide waste sizing calculations CPC Table 702.1 & Table 703.2. Note: A complete review of the waste system will be conducted upon addressing this comment. RESPONSE: Calculation is revised. See revised sheet P0.2. 8. Regarding keynote #1 on sheet Pl.0, 3" (and smaller) waste pipes are required to be sloped at 2% minimum. Please specify this on sheet Pl.0. RESPONSE: Only 6" sewer pipes run exposed in garage are sloped at 1% and other smaller pipes are run at 2%. See revised note on sheet Pl.0. 9. Within the plumbing plans, clearly specify the minimum overhead clearances that must be maintained in the garage on the plumbing plans. Identify the handicap accessible (8'2'' minimum) clearances and for areas that are not handicap accessible identity a 7'0" clearance. Note: The 8'2" clearance is required to extend from the handicap parking spaces to the entrance of the parking garage (not just above the handicap parking spaces). RESPONSE: Overhead clearance requirement is added on sheet Pl.0. 8' -2" clearance is maintained from handicap spaces up to the entrance of the garage. 10. Please correct the riser symbol call outs for the fixtures shown on sheet Pl.0 (the fixtures that feed into the pump, not the 1st and 2nd floor fixtures. RESPONSE: Riser S11, S12 and 513 are shown for basement fixtures. 11. Please either show the trap primer connections to all floor drains within the floor plans/risers or specify within the remarks for the FD-1, FD-2 and FD-3 on the Fixture Schedule on P0.2. RESPONSE: Trap primer requirement is added on sheet P0.2. 12. Cleanouts are required at the upper most terminals of all horizontal waste lines. Please provide. CPC 707.4. RESPONSE: Cleanouts are provided in compliance with CPC 707.4. b a i s e b . h i I I s I i d ah o \ a r c h i t e c t u r e , P C 3 1 5 6 s o u t h b o w n w a y 83102 Ip. 208.258.6150 I www.bhillsarch.com Building Plan Review Response Letter Oakmont Senior living (Memory Care) Carlsbad, CA Page 6 of 11 13. Detail #8 on sheet P0.3 is of a grease interceptor yet no grease interceptor is shown within the plans. Please address. RESPONSE: Grease interceptor detail is removed. See revised sheet P0.3. 14. Regarding the sewer ejector pump, please address the following: • Per CPC 710.3(3), a minimum 3" diameter discharge line is required. Please address. • Please specify the wye connection into the top of the gravity line on sheet Pl.0. RESPONSE: Sewer ejector pump: • Detail is revised to change pipe size from 2" to 3". • Wye connection is shown on sheet Pl.0. 15. Specify how storm water is going to be kept from flooding the subterranean parking garage. No trench drains are shown on sheet Pl.0. No storm water pumps are specified. Please address. RESPONSE: Storm drainage systems are shown on sheet Pl.0 and civil drawings. 16. The plumbing plans do not mention any subsoil drains. Please review CPC Section 1101 and provide the provide subsoil drainage. RESPONSE: Subsoil drainage. The structural details show the piping see sheet S6.0. The A2.1 notes that all of the subsoil drainage to extend to the sump pump for the trench drain at the bottom of the ramp. See the plumbing drawings for the location of the sump and see civil drawings for the continuation. 17. Include the main ond overflow roof drainage design calculations: Roof area, rainfall rate, pipe sizing, and drain locations on the plans. CPC 1106.0. • See CPC Table 1103.3 for sizing gutters. • See CPC Table 1101.12 for sizing roof drains, leaders and vertical storm water piping. • See Table 1101.8 for sizing horizontal storm water piping. RESPONSE: See revised sheet A2.4. The sizing information has been added. The roof drain and overflow drains are called out on the plan at each location. 18. Per City of Carlsbad, overflow roof drains shall terminate in an area where they will be readily visible and will not cause damage to the building. If the roof drain terminates through a wall, the overflow drain shall terminate 12" minimum above the roof drain. Policy 84-35. RESPONSE: See sheet A7.1 detail 'C' for the overflow termination. 19. Please state in the plans that all domestic (i.e. potable) hot water piping will have a minimum insulation for the following pipe sizes:½" pipe(½" insulation);¾" pipe (1" insulation); 1"-1 ½" pipes (1 ½" insulation); 2" pipes are larger (2" insulation). CPC 609.11 & ES 150.0(j). RESPONSE: Insulation thickness requirement is added on sheet P0.1. 20. Each dwelling unit in a multifamily building shall have the ability for shut-off of the water supply for the unit in the unit itself. Detail how this is accomplished, either by unit full way valves or by individual fixture shut-offs (include fixture stop style for bath/showers). CPC 606.3. RESPONSE: Shutoff valve is shown is added on sheet P4.1. b . h i I I s a r c h i t e c t u r e , P [ 3 1 5 6 s o u t h b o w n w a y b o i s e [ i d a h o [ 83702 [ p. 208.258.6150 [ www.bhillsarch.com Building Plan Review Response Letter Oakmont Senior Living (Memory Care) Carlsbad, CA Page 7 of 11 21. Drinking fountains are required by CPC Table 422.1 for this occupancy type (if the occupant load exceeds 30. CPC 415.2). Review the requirements of this Table and provide as necessary. Note: If food is consumed indoors, water stations may be substituted for drinking fountains. CPC 415.2. RESPONSE: Water stations will be provided. 22. Please show the commercial clothes washer (commercial dryer specified within mechanical plans) on the plumbing plans. Make sure the required water supply line, waste supply fine, structural foundation, and anchorage is specified. RESPONSE: Water and waste connections to washers are provided. 23. Provide the following information concerning the water heaters: • Show the required pump isolation valves for the recirculation pump per Energy Standard 110.3(c) • For WH-3, show P & T valve on water heater and detail the drain routing to the exterior or approved location. It may not be installed upwards from the valve. CPC 608.5 • The title of detail #6 on sheet P0.3 states kitchen water heater yet WH-3 is found in the laundry room. Please address. • Detail #1 on sheet P0.3 shows x3 water heater yet the plumbing plans only specify x2 water heaters in this room. Please correct. • Please show the location of the storage tank within the plumbing floor plans. • Please show the water heater concentric vent routing for HW-3. 24. RESPONSE: • Isolation valve is shown on both sides of CP-1 on sheet P0.3. • Floor sink is added in the room for T&P routing per detail shown on P0.3. See revised sheet P2.1. • Title of detail #6 is revised. See sheet P0.3. • Detail #1 is revised. See sheet P0.3. • Location of the storage tank is shown on sheet P2.1. • See revised mechanical plans M2.2 and M3.3. 24. For the gas riser on sheet P6.0, please address the following: • Sheet AB.9 states x3 separate fireplaces yet the riser only shows the connection of xl. Please address. • Show the gas fine routing to all appliances (i.e. W-1 & WH-2, each dryer etc.) • Specify the size of all newly shown gas lines. • Please specify the CPC Table used to size the low pressure and medium pressure lines on sheet P6.0. • Specify the total developed length used. RESPONSE: • This building is part of a bigger project. The schedule on the A8.9 is the schedule for the overall project. However the fireplace that will be used in this building is FP-3. • Gas lines to water heaters and dryers are shown. • Sizes of the gas lines are shown. • CPC Table 1216.2(11 is used to size low pressure gas pipes and 1216.2(4) to size medium pressure gas pipes. • Total developed length is shown b . h i I I s architecture. P[ 3156 south bown way b o i s e I i d a h a I 83102 j p. 208.258.6150 j www bhillsarch cam Building Plan Review Response Letter Oakmont Senior Living (Memory Care) Carlsbad, CA Page 8 of 11 MECHANICAL (2016 CALIFORNIA MECHANICAL CODE) 25. Sheet M0.2 specifies x3 kitchen grease exhaust hoods and make-up air units yet no kitchen grease hoods are shown within the mechanical plans. Please address. RESPONSE: See revised sheet M0.2. There are no kitchen hoods. Kitchen exhaust fan schedule has been removed. 26. The Serving Areas within the 1st and 2nd floor show ranges yet na exhaust ducting is shown. Please address. RESPONSE: See revised sheets Ml.1. M2.2 and M3.3 for added domestic range vent duct and termination. 2 7. Regarding the garage exhaust calculations, the square footage on sheet Ml.0 is shown to be 14,250 sq. ft. yet the title sheet species 15,921 sq. ft. (the provided EF-7 is undersized per title sheet). Please address. Note: The CFM within the calculations and the mechanical schedule are inconsistent. RESPONSE: See revised sheets Ml.1. M2.2 and M3.3 for added domestic range vent duct and termination. 28. Please correct keynote #9 on sheet Ml.0. It is pointing to the outside air duct, not an exhaust duct. RESPONSE: See revised sheet Ml.O for revised keyed note #9. 29. Since the garage exhaust fan exceeds 10,000 CFM, please comply with all the California Energy Standards requirements. RESPONSE: See added requirements on revised sheet Ml.O in Garage Ventilation Notes. 30. Clearly specify the minimum overhead clearances that must be maintained in the garage locations on the mechanical plans. If less than 8'2" is specified, clearly identify the accessible and non- accessible locations and clearances on the garage mechanical floorplans. CBC 118 502.5. RESPONSE: Please see revised sheet Ml.O. The only piece of mechanical equipment in the basement is now garage exhaust fan EF-7. This fan is located in an area that is outside vehicular traffic or parking spaces or routes to parking spaces; therefore does not require 8' -2" clearance. See architectural for added bollards. 31. Please provide the proper impact protection to the mechanical equipment within the parking garage. RESPONSE: See revised sheet A2.1. Pipe bollards have been added to protect the mechanical equipment. 32. Regarding CU-81 within the parking garage, provide the manufacture's installation instructions allowing the unit ta be installed indoors or move the unit to the outdoors. RESPONSE: See revised sheet M3.3 for new outside location of condensing unit CU-Bl. b . h i I I s a r c h i t e c t u r e . P C 3 1 5 6 s o u t h b o w n w a y b o i s e [ i d a h o [ 8 3 7 0 2 [ p 2 0 8 . 2 5 8 . 6 1 5 0 [ ww w b h i I I s arch . com Building Plan Review Response Letter Oakmont Senior Living (Memory Care) Carlsbad, CA Page 9 of 11 33. There are several areas within the mechanical plans that penetrate fire rated assemblies (corridors, shafts, sleeping unit separation walls etc.) are penetrated by ducts that do not have the proper fire protection. Review with the architect the locations that require (fire/ceiling radiation/or fire/smoke) dampers and/or shaft protection and identify installations on the mechanical plans themselves. Note: A complete review of the HVAC fire protection will be conducted upon addressing this comment. RESPONSE: See revised sheets Ml.0, Ml.1 and M2.2 for added fire and fire/smoke dampers as required. 34. Keynote #30 on sheet A4.2 & A4.3 state that the sleep unit HVAC units will be within the attic spaces. The duct work will penetrate fire rated assemblies. Please specify within the mechanical plans the proper fire protection. RESPONSE: Keyed note 30 has been revised. See revised sheets A4.1 and A4.2. The Fan Coil units do not set inside the attic space. There is a ceiling that is dropped below the fire assembly and the Fan Coil is mounted in that area. 35. Attic spaces are required to have an opening not less than. RESPONSE: See revised sheet A2.6.3 for attic access. 36. Please show the commercial dryer monufacture's installation instructions on the mechanical plans. Make sure the duct length and required amount of outside air is shown. RESPONSE: See revised commercial dryer exhaust duct sizes and added calculations on sheets Ml.l and M2.2 as well as attached manufacturer's installation instructions. Per Jeff of Speed Queen Dryers (800-552-54751 and copyright on lower part of each sheet Apex Engineers is not allowed to officially reproduce copies of this information. 37. Please show the termination location of all sleeping unit exhaust fans within the mechanical floor plan. Make sure the proper fire protection. RESPONSE: See added roof cap exhaust fan terminations added to mechanical roof plan sheet M3.3. 38. Regarding the dryer exhaust terminations on sheet Ml.1, environmental exhaust duct terminations may be no closer than 3' from a property line or 3' from openings back into the building and 10' from forced air inlets. Revise the duct layout. CMC 502.2. Note: Residential dryers cannot only extend 14' with x2 90-degree elbow turns. RESPONSE: See revised sheets Ml.1 and M2.2 for added compliance to CMC 502.2.1 and CMC 504.4.2.1 for domestic dryer vents. 39. Regarding all the sleeping units, environmental exhaust duct terminations may be no closer than 3' from a property line or 3' from openings back into the building and 10' from forced air inlets. Revise the duct layout or clearly note on the plans that the exhaust termination will be no closer than 3' to the window and no closer than 10' to a forced air inlet. CMC 502.2.1. RESPONSE: See revised mechanical roof plan sheet M3.3 for added requirements for termination of all sleeping unit exhaust fans. b . h i I I s b o i s e \ i d a h o I architecture, PC 3156 83102 Ip 208.258.6150 s o u t h b o w n w a y www. bh i 11 sarch c om Building Plan Review Response Letter Oakmont Senior Living (Memory Care) Carlsbad, CA Page 10 of 11 40. For CU-1, CU-2, CU-3 and CU-4 (provide separate calculations for each), please provide calculations that show compliance with CMC 1104.2 "Refrigerant Concentration Limit" for the worst-case concentration/area scenario (i.e. please see CMC Table 1102.2 for allowable quantities). RESPONSE: CU-4 has been split into two separate condensing units CU-4 and CU-5 to comply with CMC table 1104.2 and ASHRAE 15. See revised sheets Ml.1 and M2.2 for added calculations for ASHRAE 15 compliance for all 5 condensing units CU-1 through CU-5. 41. Duct work cannot penetrate exit stairways. Please correct sheet M2.2. CBC 1023.5. RESPONSE: See revised sheet M2.2. Ductwork has been removed from the stairwell. 42. The mechanical plans show ducts that extend from the basement level to the roof without any shaft protection. Please correct. RESPONSE: See revised sheets Ml.1 and M2.2 ductwork is now in shafts. 43. Please show the condensate waste design (primary and secondary) for all common area fan coils. RESPONSE: See sheets Ml.01, Ml.2 and M2.3 for condensate drainage piping for all common area fan coil units. 44. Please specify why a supply fan and gravity air intake vent is supplying the same mechanical room. RESPONSE: Per CMC 701.9 for mechanical combustion air CFM (required) = 0.35 cfm / 1000 Btuh. Cfm (required) = 0.35 / 398 mbtuh. CFM (required) = 139. CFM (provided) = 490. Supply fan SF-1 provides 490 cfm of combustion air. Gravity relief GR-1 provides 490 cfm of relief for water heater room. See M2.2. M3.3 and M0.2 for equipment schedules. 45. Please correct keynote #7 on sheet M2.2. It appears that the 22" exhaust fan and all the refrigerant lines will not be able to fit into the size of the shown shaft. RESPONSE: Please see revised duct shaft and added duct riser diagram 3/M0.6. 46. The outside air rates shown within the schedule on sheet MD.3 is incorrect per California Energy Standards. Please see right hand column of Table 4-16 for the proper rates. Please upsize accordingly. RESPONSE: See revised outside air calculations on sheet M0.3. See revised sheets Ml.0, Ml.1, M2.2 for revised air quantities in each room. See revised sheet M02 for revised outside air fans and exhaust fans. 47. All exhaust systems in residential bathrooms that are not used for whole house ventilation requires o humidistat. Please address Ca/Green 4.506. RESPONSE: This code section is not applicable. All toilet exhaust fans serving residential bathrooms run continuous as required by whole house ventilation system requirements. b . h i I I s a r c h i t e c t LI r e , P [ 3 1 5 6 s o LI t h b o w n w a y b o i s e I i d ah o I 83102 p 208.258.6150 \ www.bhillsarch.com Building Plan Review Response Letter Oakmont Senior Living (Memory Care) Carlsbad, CA Page 11 of 11 48. Please provide smoke detection in the supply air duct of any "air-moving system" (equal to or greater than 2,000 cfm) to shut-off the equipment/or smoke control. CMC Section 608.1 • An "air-moving system" is a system designed to provide heating, cooling, or ventilation in which one or more air-handling units are used to supply air to a common space or to draw air from a common plenum or space. RESPONSE: The two rooms that have systems over 2000 cfm are the first floor and second floor dining rooms (numbers 1111 and 2107). Both rooms qualify for CMC section 608.1 exception #2. Room 1111 has direct access to the exterior. Room 2107 is within 100 feet of stairwell 2100 ELECTRICAL and ENERGY COMMENTS ELECTRICAL (2016 CALIFORNIA ELECTRICAL CODE) 49. Room 1111 is missing one exit sign/light at southwest door. Please ensure there is also an emergency light at that exterior fonding. RESPONSE: Exit sign is added in room 1111. Emergency lighting is shown at all exterior landings. See revised sheet E2.1. 50. CEC 422.51 If installing vending machines, they shall be provided with GFCI protection. The GFCI device shall be readily accessible. RESPONSE: No vending machines are installed. 51. CEC 422.521/ installing drinking fountains, they shall be provided with GFCI protection. The GFCI device shall be readily accessible. RESPONSE: No vending machines are installed. ENERGY (2016 CALIFORNIA BUILDING ENERGY STANDARDS) 52. Energy design is approved. RESPONSE: Noted Sincerely, b.hills architecture, P.C. Linden Severe b . h i I I s a r , h i t e c t u r e , P C 3 1 5 6 s o u t h b o w n w a y b o i s e i d ah o 8 3 1 0 2 I p 2 0 8 2 5 8 . 6 1 5 0 ww w b h i I I s a r ch . com -✓• EsG1I A \AFEbwlt Company DATE: December 9, 2019 JURISDICTION: Carlsbad □ APPLICANT □ JURIS. PLAN CHECK#.: CBC2019-0530 SETI PROJECT ADDRESS: 2540 Faraday Ave. PROJECT NAME: Oakmont of Carlsbad Memory Care D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Byron Hills D EsGil staff did not advise the applicant that the plan check has been completed. ~ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Byron Hills Date contacted: (by: Telephone#: 208-258-6154 ) Email: BHills@BHillsArch.com Mail Telephone Fax In Person 0 REMARKS: By: Kurt Culver, S.E. Enclosures: EsGil 11/15/19 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBC2019-0530 .. December 9, 2019 PLAN REVIEW CORRECTION LIST MULTI-FAMILY PLAN CHECK#.: CBC2019-0530 REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: December 9, 2019 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad DATE PLANS RECEIVED BY ESGIL CORPORATION: 11/15/19 PLAN REVIEWER: Kurt Culver, S.E. This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Building Code (Title 24 ), which adopts the following model codes: 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBC2019-0530 ~ December 9, 2019 GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. PLANS 2. All sheets of the plans are required to be signed by the licensed architect or engineer responsible for the plan preparation. California State Law. 3. Please provide the grading plans (civils) so that site slopes can be verified for disabled access compliance. 4. Revise the exit sign locations on the electrical plans at Room 1111 so that the sign is at the swinging door (not at the bi-fold door). 5. In each story of a mixed occupancy building, the maximum number of occupants served by a single exit shall be such that the sum of the ratios of the calculated number of occupants of the space divided by the allowable number of occupants for each occupancy does not exceed one. Section 1006.3.2.1. a) Although the garage occupants have access to 2 exits, occupants in Rooms G114/107/108 only have access to 1 exit. Per Section 1006.3.2.1, it appears that 2 exits must be provided (and passing through the garage is not permitted). 6. At A/A4.3, please clarify the construction of the curved wall behind the row of seats. Since this portion of the building is Type I Construction, wood studs are not allowed. Carlsbad CBC2019-0530 December 9, 2019 7. One in every eight accessible spaces, but not less than one, shall be served by an access aisle 8' wide minimum and shall be designated van accessible with a sign "Van Accessible" mounted below the symbol of accessibility. Alternately, the parking space may be 12' wide with the access aisle 5' wide. Section 1109A.8.6. The access aisle shall be located on the passenger side of the vehicle. SHEET A2.1 SHOWS IT ON THE WRONG SIDE. 8. Exit doors shall swing in the direction of exit travel when serving a room containing an occupant load of 50 or more persons or a Group H occupancy. Section 1010.1.2.1. a) Since the room (garage) has more than 49 people, Door G116 must swing the other way. b) Doors 1220 and 1221 must swing the other way. 9. Each door in a means of egress from an occupancy of Group A having an occupant load of 50 or more shall not be provided with a latch or lock unless it is panic hardware. Section 1010.1.10. a) Door 1114. 10. In R-1, R-2 and R-3 occupancies, where window openings are > 72" above grade, then the lowest part of the window opening shall be at least 36" above the floor. Section 1015.8. STRUCTURAL 11. Provide a copy of the project soil report prepared by a licensed civil engineer. The report shall include foundation design recommendations based on the engineer's findings. 12. In Seismic Design Categories D, E or F, the soils investigation must address liquefaction, and, if retaining walls are proposed, the soils investigation must address increased loading on the walls due to earthquake motions. Section 1803.5.12. 13. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soil report are properly incorporated into the plans (when required by the soil report). 14. Carlsbad requires that their unique Special Inspection Program (available on their website) be completed, signed and returned. Carlsbad CBC2019-0530 December 9, 2019 ADDITIONAL 15. Please see below for MEP corrections. 16. To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 17. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: □ Yes □ No 18. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Kurt Culver, S.E. at Esgil Corporation. Thank you. PLUMBING AND MECHANICAL COMMENTS PLAN REVIEWER: Connor Reuss SET: I GENERAL P&M ITEMS 1. Pleas provide the fireplace manufacturer's installation instructions. Make sure the required clearances are specified. 2. Please clearly specify all fire rated assemblies and review with the mechanical designer to ensure all HVAC penetrations are equipped with the proper fire protection. 3. Keynote #30 on sheet A4.2 and A4.3 state the sleeping unit HVAC units will be within the attic. Access is required to be no smaller than the largest component of the appliance, yet not less than 22" by 30". Please address. Carlsbad CBC2019-0530 December 9, 2019 PLUMBING (2016 CALIFORNIA PLUMBING CODE) 4. Provide a plumbing material schedule on the plans describing the following systems: Potable water piping, the drain, waste, and vent piping, gas piping, and the roof drains. Note: In addition, please address the following bullet points. • In areas of residential accommodation drainage piping material (i.e. waste, vent and storm drainage) types ABS and PVC are limited to buildings of two stories or less. All buildings that have 3 or more levels of residential units cannot use PVC or ABS. Please address. CPC 701.2(a), CPC 903.1.1, & CPC 1101.4 • Certification of Compliance is necessary when installing CPVC/PEX water piping materials prior to building permit issuance. CPC 604.1.1 (CPVC)/CPC 604.1.2(PEX) Note: Please specify this within the material schedule. 5. For backwater valve review, please show the upstream sewer manhole rim and finished floor elevations. CPC 710.0 • Mandatory: Fixtures installed on a floor level below the next upstream manhole cover require backwater protection. 6. Please either provide approval from the Building Official allowing the use of CPC Appendix C (i.e CPC page XVI: "Alternative methods are allowed to be used where approved by the authority having jurisdiction.') for sizing the water lines or provide water sizing calculations per CPC 610.0 or Appendix 'A'. Note: A complete review of the water system will be conducted upon addressing this comment. 7. Please either provide approval from the Building Official allowing the use of CPC Appendix C (i.e CPC page XVI: "Alternative methods are allowed to be used where approved by the authority having jurisdiction.') for sizing the waste lines or provide waste sizing calculations CPC Table 702.1 & Table 703.2. Note: A complete review of the waste system will be conducted upon addressing this comment. 8. Regarding keynote #1 on sheet P1 .0, 3" (and smaller) waste pipes are required to be sloped at 2% minimum. Please specify this on sheet P1 .0. 9. Within the plumbing plans, clearly specify the minimum overhead clearances that must be maintained in the garage on the plumbing plans. Identify the handicap accessible (8'2" minimum) clearances and for areas that are not handicap accessible identity a 7'0" clearance. Note: The 8'2" clearance is required to extend from the handicap parking spaces to the entrance of the parking garage (not just above the handicap parking spaces). 10. Please correct the riser symbol call outs for the fixtures shown on sheet P1 .0 (the fixtures that feed into the pump, not the 1st and 2nd floor fixtures. A Carlsbad CBC2019-0530 December 9, 2019 11. Please either show the trap primer connections to all floor drains within the floor plans/risers or specify within the remarks for the FD-1, FD-2 and FD-3 on the Fixture Schedule on P0.2. 12. Cleanouts are required at the upper most terminals of all horizonal waste lines. Please provide. CPC 707.4 13. Detail #8 on sheet P0.3 is of a grease interceptor yet no grease interceptor is shown within the plans. Please address. 14. Regarding the sewer ejector pump, please address the following: • Per CPC 710.3(3), a minimum 3" diameter discharge line is required. Please address. • Please specify the wye connection into the top of the gravity line on sheet P1 .0. 15. Specify how storm water is going to be kept from flooding the subterranean parking garage. No trench drains are shown on sheet P1 .0. No storm water pumps are specified. Please address. 16. The plumbing plans do not mention any subsoil drains. Please review CPC Section 1101 and provide the provide subsoil drainage. 17. Include the main and overflow roof drainage design calculations: Roof area, rainfall rate, pipe sizing, and drain locations on the plans. CPC 1106.0. • See CPC Table 1103.3 for sizing gutters. • See CPC Table 1101.12 for sizing roof drains, leaders and vertical stormwater piping. • See Table 1101.8 for sizing horizontal storm water piping. 18. Per City of Carlsbad, overflow roof drains shall terminate in an area where they will be readily visible and will not cause damage to the building. If the roof drain terminates through a wall, the overflow drain shall terminate 12" minimum above the roof drain. Policy 84-35. 19. Please state in the plans that all domestic (i.e. potable) hot water piping will have a minimum insulation for the following pipe sizes: ½" pipe (½" insulation); ¾" pipe (1" insulation); 1 "-1 ½" pipes (1 ½" insulation); 2" pipes are larger (2" insulation). CPC 609.11 & ES 150.0G) 20. Each dwelling unit in a multifamily building shall have the ability for shut-off of the water supply for the unit in the unit itself. Detail how this is accomplished, either by unit full way valves or by individual fixture shut-offs (include fixture stop style for bath/showers). CPC 606.3 Carlsbad CBC2019-0530 December 9, 2019 21. Drinking fountains are required by CPC Table 422.1 for this occupancy type (if the occupant load exceeds 30. CPC 415.2). Review the requirements of this Table and provide as necessary. Note: If food is consumed indoors, water stations may be substituted for drinking fountains. CPC 415.2 22. Please show the commercial clothes washer (commercial dryer specified within mechanical plans) on the plumbing plans. Make sure the required water supply line, waste supply line, structural foundation, and anchorage is specified. 23. Provide the following information concerning the water heaters: • Show the required pump isolation valves for the recirculation pump per Energy Standard 110.3(c) • For WH-3, show P & T valve on water heater and detail the drain routing to the exterior or approved location. It may not be installed upwards from the valve. CPC 608.5 • The title of detail #6 on sheet P0.3 states kitchen water heater yet WH-3 is found in the laundry room. Please address. • Detail #1 on sheet P0.3 shows x3 water heater yet the plumbing plans only specify x2 water heaters in this room. Please correct. • Please show the location of the storage tank within the plumbing floor plans. • Please show the water heater concentric vent routing for HW-3. 24. For the gas riser on sheet P6.0, please address the following: • Sheet AB.9 states x3 separate fireplaces yet the riser only shows the connection of x1. Please address. • Show the gas line routing to all appliances (i.e. W-1 & WH-2, each dryer etc.) • Specify the size of all newly shown gas lines. • Please specify the CPC Table used to size the low pressure and medium pressure lines on sheet P6.0. • Specify the total developed length used. Carlsbad CBC2019-0530 December 9, 2019 MECHANICAL (2016 CALIFORNIA MECHANICAL CODE) 25. Sheet M0.2 specifies x3 kitchen grease exhaust hoods and make-up air units yet no kitchen grease hoods are shown within the mechanical plans. Please address. 26. The Serving Areas within the 1st and 2nd floor show ranges yet no exhaust ducting is shown. Please address. 27. Regarding the garage exhaust calculations, the square footage on sheet M1 .0 is shown to be 14,250 sq. ft. yet the title sheet species 15,921 sq. ft. (the provided EF- 7 is undersized per title sheet). Please address. Note: The CFM within the calculations and the mechanical schedule are inconsistent. 28. Please correct keynote #9 on sheet M1 .0. It is pointing to the outside air duct, not an exhaust duct. 29. Since the garage exhaust fan exceeds 10,000 CFM, please comply with all the California Energy Standards requirements. 30. Clearly specify the minimum overhead clearances that must be maintained in the garage locations on the mechanical plans. If less than 8'2" is specified, clearly identify the accessible and non-accessible locations and clearances on the garage mechanical floorplans. CBC 11 B 502.5. 31. Please provide the proper impact protection to the mechanical equipment within the parking garage. 32. Regarding CU-B1 within the parking garage, provide the manufacture's installation instructions allowing the unit to be installed indoors or move the unit to the outdoors. 33. There are several areas within the mechanical plans that penetrate fire rated assemblies (corridors, shafts, sleeping unit separation walls etc.) are penetrated by ducts that do not have the proper fire protection. Review with the architect the locations that require (fire/ceiling radiation/or fire/smoke) dampers and/or shaft protection and identify installations on the mechanical plans themselves. Note: A complete review of the HVAC fire protection will be conducted upon addressing this comment. 34. Keynote #30 on sheet A4.2 & A4.3 state that the sleep unit HVAC units will be within the attic spaces. The duct work will penetrate fire rated assemblies. Please specify within the mechanical plans the proper fire protection. 35. Attic spaces are required to have an opening not less than 36. Please show the commercial dryer manufacture's installation instructions on the mechanical plans. Make sure the duct length and required amount of outside air is shown. 37. Please show the termination location of all sleeping unit exhaust fans within the mechanical floor plan. Make sure the proper fire protection Carlsbad CBC2019-0530 December 9, 2019 38. Regarding the dryer exhaust terminations on sheet M1 .1, environmental exhaust duct terminations may be no closer than 3' from a property line or 3' from openings back into the building and 10' from forced air inlets. Revise the duct layout. CMC 502.2. Note: Residential dryers cannot only extend 14' with x2 90-degree elbow turns. 39. Regarding all the sleeping units, environmental exhaust duct terminations may be no closer than 3' from a property line or 3' from openings back into the building and 1 0' from forced air inlets. Revise the duct layout or clearly note on the plans that the exhaust termination will be no closer than 3' to the window and no closer than 1 0' to a forced air inlet. CMC 502.2.1 40. For CU-1, CU-2, CU-3 and CU-4 (provide sperate calculations for each), please provide calculations that show compliance with CMC 1104.2 "Refrigerant Concentration Limit" for the worst-case concentration/area scenario (i.e. please see CMC Table 1102.2 for allowable quantities). 41. Duct work cannot penetrate exit stairways. Please correct sheet M2.2. CBC 1023.5 42. The mechanical plans show ducts that extend from the basement level to the roof without any shaft protection. Please correct. 43. Please show the condensate waste design (primary and secondary) for all common area fan coils. 44. Please specify why a supply fan and gravity air intake vent is supplying the same mechanical room. 45. Please correct keynote #7 on sheet M2.2. It appears that the 22" exhaust fan and all the refrigerant lines will not be able to fit into the size of the shown shaft. 46. The outside air rates shown within the schedule on sheet M0.3 is incorrect per California Energy Standards. Please see right hand column of Table 4-16 for the proper rates. Please upsize accordingly. 47. All exhaust systems in residential bathrooms that are not used for whole house ventilation requires a humidistat. Please address CalGreen 4.506 48. Please provide smoke detection in the supply air duct of any "air-moving system" (equal to or greater than 2,000 cfm) to shut-off the equipment for smoke control. CMC Section 608.1 • An "air-moving system" is a system designed to provide heating, cooling, or ventilation in which one or more air-handling units are used to supply air to a common space or to draw air from a common plenum or space. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Connor Reuss at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. Carlsbad CBC2019-0530 December 9, 2019 ELECTRICAL and ENERGY COMMENTS PLAN REVIEWER: Scott Humphrey ELECTRICAL (2016 CALIFORNIA ELECTRICAL CODE) 49. Room 1111 is missing one exit sign/light at southwest door. Please ensure there is also an emergency light at that exterior landing. 50. CEC 422.51 If installing vending machines, they shall be provided with GFCI protection. The GFCI device shall be readily accessible. 51. CEC 422.52 If installing drinking fountains, they shall be provided with GFCI protection. The GFCI device shall be readily accessible. ENERGY (2016 CALIFORNIA BUILDING ENERGY STANDARDS) 52. Energy design is approved. Note: If you have any questions regarding this Electrical, Plumbing, Mechanical, and Energy plan review list please contact Scott Humphrey at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. Carlsbad CBC2019-0530 • December 9, 2019 [DO NOT PAY -THIS IS NOT AN INVOICE} VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Kurt Culver, S.E. BUILDING ADDRESS: 2540 Faraday Ave. BUILDING OCCUPANCY: R-2.1 BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Care Facilitv Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance ------------- 1997 USC Buildln Permit Fee g ..,, 1997 UBC Plan Check Fee .., I Type of Review: D Repetitive Fee ---; I Repeats __ _J Comments: Complete Review D Other □ Hourly EsGil Fee PLAN CHECK#.: CBC2019-0530 DATE: December 9, 2019 Reg. VALUE ($) Mod. 7,065,241 7,065,241 D Structural Only $10,143.151 Sheet 1 of 1 (' (:itv of c~irlsbad PC2019-0050 Building Permit Number: CBCA2020-0116 Community & Economic Development COMMUNITY FACILITIES DISTRICT NON-RESIDENTIAL .NON-RESIDENTIAL CERTIFICATE: Non-residential land owner, please read this option carefully and be sure you thoroughly understand before signing. Ih~ option you choose wilJ i'!ffect your payment of the developed Special Tax assessed on your property. This option is available only at the time of the first building permit issuance. Property owner signature is required before permit issuance. Your signature confirms the accuracy of all information shown below. _OAKMONT OF CARLSBAD LLC Name of Owner 9240 OLD REDWOOD HWY ::iUIIE 200 Address WINDSOR CA 95492 City, State Zip 2091200100 Assessor Parcel Number (APN} Lot Number Improvement Are, ,05/21/2004 Annexation Date Telephone 2560 Faraday Ave Project Address CARLSBAD, CA City, State ALL OTHER COMMERCIAL USES 92008 Zip Land Use Type $0,3406 _128,314.0Q_ ,2019-202Q__ Factor Square Feet Fiscal Year As cited by Ordinance No. NS-155 and adopted by the City of Carlsbad, California, the City is authorized to levy a Special Tax in Community Facilities District No. 1. All non-residential property, upon the issuance of a building permit, shall have the option to (1} pay the SPECIAL DEVELOPMENT TAX ONE TIME or (2) assume the ANNUAL SPECIAL TAX -DEVELOPED PROPERTY for a period not to exceed twenty-five (25) years. Please indicate your choice by initialing the appropriate line below: OPTION (1): I elect to pay the SPECIAL TAX -ONE TIME now, as a one-time paymen;;;L Amount of One-Time Special Tax: $43,703.7S Owner's Initials ~VJ~- OPTION (2): I elect to pay the SPECIAL DEVELOPMENT TAX ANNUALLY for a period not to exceed twenty-five (25) years. Maximum Annual Special Tax: $6,035.49 Owner's Initials __ _ I DO HEREBY CERTIFY UNDER PENAL TY OF PERJURY THAT THE UNDERSIGNED IS THE PROPERTY OWNER OF THE SUBJECT PROPERTY AND THAT I UNDERSTAND AND WILL COMPLY WITH THE PROVISION AS STATED ABOVE. David Hunter Print Name B-32 Director Title 8/6/2020 Date Page I of I CITY OF CARLSBAD COMMUNITY FACILITIES DISTRICT NO. 1 SPECIAL DEVELOPMENT TAX - ONE-TIME IMPROVEMENT AREA I (4 PAGES) U VALID JULY 1, 2019 TO JUNE 30, 2020 FORMATION OR ANNEXATION DATE: RE SIDENTIAL DEVELOPED LAND USE: NO NET DENSITY 0 -1.5 DU/ACl NET DENSITY 1.51 TO 4.0 DU/AC) NET DENSITY 4.1 TO8.0DU/ACl NET DENSITY 8.1 TO 15.0DU/ACl NET DENSITY 15.1 TO 23.0 DU/AC) N-RESIDENTIAL LAND USE: AUTO -GASOLINE AUTO -REPAIR & SALES AUTO CAR WASH BANK-WALK IN BANK -WITH DRIVE THRU BOWLING ALLEY CAMPGROUND CHURCH COMMERCIAL SHOPS COMMUNITY SHOPPING CENTER CONVENIENCE MARKET DISCOUNT STORE GOLF COURSE GROCERY STORE HEALTH CLUB HELIPORTS HOSPITAL· CONVALESCENT HOSPITAL -GENERAL HOTEL -CONV. FAG/COMM INDOOR SPORTS ARENA INDUSTRIAL -COMMERCIAL BUSINESS PARK /NOTE 11 JUNIOR COLLEGE LIBRARY LUMBER/HARDWARE STORE MARINA MOTEL NEIGHBORHOOD SHOPPING CENTER OFFICE -COMMERCIAL/< 100,000 SFl OFFICE -GOVERNMENT OFFICE -HIGH RISE OFFICE -MEDICAL OUTDOOR TENNIS COURT RACE TRACK REGIONAL SHOPPING CENTER RESORT HOTEL RESTAURANT -FAST FOOD RESTAURANT -QUALITY RESTAURANT -SIT DOWN S & L-WALK IN S & L -WITH DRIVE THRU UNIVERSITY ALL OTHER COMMERCIAL USES NOT IDENTIFIED ABOVE ALL OTHER INDUSTRIAL USES NOT IDENTIFIED ABOVE (NOTE 2) NOTE 1: THIS CATEGORY OF LAND USE CONTAINS PM AND CM ZONED PROPERTY. NOTE 2: THIS CATEGORY OF LAND USE OONTAINS MAND PU ZONED PROPERTY. FY 1999-00 PERDU. $4,383.0823 $4,383.0823 $2,766.5007 $2,766.5007 $2,766.5007 PER SQ.FT. $1.2284 $0.5165 $0.9557 $1.9433 $2. 7355 $1.0042 $2.6521 $0.4529 $0.4392 $0.6422 $4.1365 $0.4877 $0.4635 $1.1784 $0.4377 $1,6101 $0.3529 $0.5877 $0.5256 $0.3529 $0 3241 $0.3317 $0.6452 $0.3741 $2.2492 $0.4074 $0.9785 $0.3877 $0.4438 $0.4044 $0.3665 $4.2622 $0.7725 $0.5074 $0.3484 $4.3107 $0.9951 $2.2977 $0.8346 $1.1496 $0.3423 $0.3241 $0.2635 RECORD COPY FY 2000-01 PER DU. $4,454.2292 $4,454.2292 $2,811.4070 $2,811.4070 $2,811.4070 PER SQ.FT. $1.2483 $0.5249 $0.9713 $1.9748 $2. 7799 $1.D205 $2.6952 $0.4602 $0.4464 $0.6526 $4.2036 $0.4956 $0.4710 $1.1975 $0.4448 $1.6362 $0.3586 $0.5972 $0.5341 $0.3586 $0.3294 $0.3371 $0.6557 $0.3802 $2.2858 $0.4141 $0.9943 $0.3940 $0.4510 $0.4110 $0.3725 $4 3314 $0.7850 $0.5156 $0.3540 $4.3807 $1.0113 $2.3350 $0.8481 $1.1683 $0.3479 $0 3294 $0.2678 IMPROVEMENT AREA I fPaae 2 of 41 ACTUAL TAX RATE FOR FY 2019-20 (65% OF THE MAXIMUM FOR RESIDENTIAL - 10% OF THE MAXIMUM FOR NONRESIDENTIAL) FY 2001-02 FY 2002-03 FY 2003-04 PER DU. PERDU. PERDU. $4,520.0553 $4,564.8083 $4,605.5251 $4,520.0553 $4,564.8083 $4,605.5251 $2,852.9549 $2,881.2020 $2,906.9015 $2,852.9549 $2,881.2020 $2,906.9015 $2,852.9549 $2,881.2020 $2,906.9015 PER SQ.FT. PER SQ.FT. PER SQ.FT. $1.2668 $1.2793 $1.2907 $0.5326 $0.5379 $0.5427 $0.9856 $0.9954 $1.0042 $2.0040 $2.0239 $2.0419 $2.8209 $2.8489 $2.8743 $1.0356 $1.0458 $1.0552 $2.7350 $2.7621 $2.7867 $0.4670 $0.4717 $0.4759 $0.4530 $0.4575 $0.4615 $0.6623 $0.6688 $0.6748 $4.2658 $4.3080 $4.3464 $0.5030 $0.5079 $0.5125 $0.4780 $0.4827 $0.4870 $1.2152 $1.2273 $1.2382 $0.4514 $0.4559 $0.4599 $1.6604 $1.6768 '1:1.6918 $0.3639 $0.3675 $0.37Utl $0.6060 $0.6120 175 $0.5420 $0.5474 $0.5523 $0.3639 $0.3675 $0.3708 $0.3343 $0.3376 $0.3406 $0.3421 $0.3455 $0.3485 $0.6654 $0.6720 $0.6780 $0.3858 $0.3896 $0.3931 $2.3195 $2.3425 $2.3634 $0.4202 $0.4243 $0.4281 $1.0090 $1.0190 $1.0281 $0.3999 $0.4038 $0.4074 $0.4577 $0.4622 $0.4663 $0.4170 $0.4212 $0.4249 $0.3780 $0.3817 $0 3851 $4.3954 $4.4389 $4.4785 $0.7966 $0.8045 $0.8117 $0.5233 $0.5284 $0.5332 $0.3593 $0.3628 $0.3660 $4.4454 $4.4894 $4.5295 $1.0262 $1.0364 $1.0456 $2.3695 $2.3930 $2.4143 $0.8607 $0.8692 $0.8769 $1.1855 $11973 $1.2080 $0.3530 $0.3565 $0.3597 $0.3343 $0.3376 $0.3406 $0.2718 $0.2745 $0.2769 Appendix E -Page 10 of 16 FY 2004-05 FY 2005-06 PERDU. PER DU. $4,671.3508 $4,814.0047 $4,671.3508 $4,814.0047 $2,948.4491 $3,038.4890 $2,948.4491 $3,038.4890 $2,948.4491 $3,038.4890 PER SQ.FT. PER SQ.FT. $1.3092 $1.3491 $0.5505 $0.5673 $1.0186 $1.0497 $2.0711 $2.1343 $2.9154 $3.0044 $1.0703 $1.1029 $2.8266 $2.9129 $0.4827 $0,4974 $0.4681 $0.4824 $0.6844 $0.7053 $4.4085 $4.5432 $0.5198 $0.5357 $0.4940 $0 5090 $1.2559 $1.2942 $0.4665 $0.4808 $1.7160 $1.7684 ~ $0.3761 $0.3876 $0.6263 $0.6455 $0.5601 $0.5773 $0.3761 $0 3876 $0.3455 $0.3560 $0.3535 $0.3643 $0.6877 $0.7087 $0.3987 $0.4109 $2.3972 $2.4704 $0.4342 $0.4475 $1.0428 $1.0747 $0.4133 $0.4259 $0.4730 $0.4874 $0.4310 $0.4442 $0.3907 $0.4026 $4.5425 $4.6813 $0.8233 $0.8484 $0.5408 $0.5573 $0.3713 $0.3826 $4.5942 $4.7345 $1.0606 $1.0930 $2.4488 $2 5236 $0.8895 $0.9166 $1.2252 $1.2626 $0.3648 $0.3760 $0.3455 $0 3560 $0.2809 $0.2895 (_ City of Carlsbad · CERTI ICATION OF SCHOOL FEES PAID This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City prior to Issuing a building permit. The City will not Issue any building permit without a completed school fee form. Project # & Name: Permit#: Project Addre11: Aaaeuor's Parcel #: Project Applicant: (Owner Name) DEV2017-0042, OAKMONT OF CARLSBAD CBC201:.::.9·.::0:::.,53:.::0 __________ _ 2540 FARADAY AVE 2091200100 OAKMONT OF CARLSBAD LLC Re1ldentlal Square Feet: New/Additions: @ C1rt1bld Unified School Dl1trtct 8225 El Camino Real Carlsbad CA 92009 Phone: (760) 331-5000 □ Enclnlta Union School Dlatrlct 101 South Rancho Santa Fe Rd Encinitas, CA 92024 Phone: (780) 944-4300 x1168 D San Dlqutto Union H.S. Dl1trtct 684 Requeza Dr. Encinitas, CA 92024 Second Dwelling Unit: ___ _ JUNO 8 Phone: (780) 753-e491 Ext 5514 ------···--1f12n........-. (By Appl. Only) Commercial Square Feet: New/Addltlona: ... 42_.,7.4_9 ______________ _ City Certiflcatlon:Clty of Carlsbad Bulldln& Division Date: 03/04/2020 Certification of Appllcant/Ownera. The person executing thla declaration ("Owner") cartllle1 under penalty of perjury that (1) the lnformaUon provided above 11 correct and true to the beat of the Owne~s knowledge, and that the Owner will file an amended certification of payment and pay the additional fee If Owner requeata an lrn:rea■e In the number of dweHlng untt■ or equare footage aflar the building permtt II l11ued or If the lnttlal determination of untt■ or ■quare footage 11 found to be Incorrect, and that (2) Iha Owner le the owner/developer of the above deecrtbed project(e), or that Iha person executing thla declaration 11 authorized to algn on behalf of the Owner. D San Marcoa Unified Sch. Dlatrtct 255 Pico Ave Ste. 100 San Marcos, CA 92069 Phone: (780) 290-2849 Contact: Katherine Marceija (By Appl.only) D Vista Unified School District 1234 Arcadia Drive Vista CA 92083 Phone: (760) 726-2170 x2222 SCHOOL DISTRICT SCHOOL FEE CERTIFICATION (To be completed by the school dlstrlct(s)) THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE PROJECT HAVE BEEN OR WILL BE SATISFIED. The under11lgned, being duly authorized by the applicable School District, certlflu that the developer, bullder, or owner h■1 Ntlllfled the obligation for achool facllltle■. Thi• le to certify that the applicant Hated on page 1 h■1 paid ■11 amount■ or completed other ■ppllc■ble ■chool mitigation determined by the School District, The City may l■■ue bufldlng permit■ for thla proJact. Signature of Authorized School District OfflclalJ).'.'.\_,~.J-:::Y::,{C~::•c:, .... (~t<::~:\c'c< l,._1,_;_.C, .. Q_ .... . le::. -ec.--'-·""'N;\J-N, v"\) Title· L · 'A.\, -"AA. -..l' '\--Date· I s-, "'·:, r-· ... ,..)_\...\,v)4-~~ -ctm:sn-An1JflwifuSCHOOtO:Sf!'tit:f-·--· ··-----··-···-.... ' .. !,C.:.~.'. -~~l:::t,;~.l ... ·- Name of School District:_ 6225 EL CAMINO REAL_____ __ ·----·--•---•··-··--· .. ----------Phone: 1 lrt'-_·35/ ·-f:SNYJ CARLSBAD, CA 92009 Community & Economic Development -Bulldlng Division 1635 raraday Avenue I Carlsbad, CA 92008 I 760-602-2719 I 760-602-8558 fax I bulldlng@)carlsbadca.gov OFFICE USE ONLY SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE j RECORD ID# ________________ _ 1 PLAN CHECK# _________________ _ BP DATE __ ~-~-- Business Name Business Contact Oakmont of Carlsbad Gregg Wanke ProJe'ct AddreSs City 2540 Faraday Avenue Carlsbad ·--Maillri9...Address ---.... ------------------------··· ·----_,_ __ City___ ----·- 8240 Old Redwood Hwy, Suite 200, Windsor, CA 95492 State Project· c·ontact- Gregg Wanke --·-------·-Applicant E-man gregg.wanke@oakmontsl.com re1ePhone·# - Zip COde - Zip C0de 707-535-3200 iAPN# ! 209-120-01-00 i8Jeph0ne # 707-535-3234 ·rt:.-e· following questions represent the facility'$ activities;·Nor·the specifiC proje·ctdesCription. I j PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION:~not required for projects within_ the City of San Diego): Indicate by circling the item, whether your business will use, process, or store any of the following azardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal Occupancy Rating: Facility's Square Footage (including proposed project}: 1 Explosive or Blasting Agents 5. Organic Peroxides 9 Water Reacl1ves 13 Corrosives 2 Co1:1pressed Gases 6. Oxidizers 10 Cryogenics 14. Other Health Hazards 3 Flammable/Combustible Liquids 7 Pyrophorics 11 Highly Toxic or Toxic Materials 15 None of These 4 Flammable Solids 8. Unstable Reactives 12 Radioactives PART 111 SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEAL TH -HAZARDOUS MATERIALS DIVISION HMD , If the answer to any of the questions 1s yes. applicant must contact the aunty of an Diego Hazardous Materials ivision, 5500 verland Avenue, uite 110, San Diego. CA 92123 Call (858) 505-6700 prior to the issuance of a building permit FEES ARE REQUIRED Project Completion Date Expected Date of Occupancy 0 CalARP Exempt I 1 2 3. 4 5 6 7 8 YES NO (foF new construction or remodeling proJed:s) Is your business listed on the reverse side of this form? {check all that apply) □ 11(1 □ l&:I □ IX! Will your business dispose of Hazardous Substances or Medical Waste in any amount? Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 pounds and/or 200 cubic feet? □ □ □ □ □ ~ Will your business store or handle carcinogens/reproductive toxins in any quantity? ~ Will your business use an existing or install an underground storage tank? @ Will your business store or handle Regulated Substances (CalARP)? Kl Will your business use or install a Hazardous Waste Tank System {Title 22, Article 10)? iJ Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to or oreater than 1,320 aliens? (California's Above round Petroleum Stora e Act). Date 0 CalARP Required I Date Initials 0 CalARP Complete I Date lrnt1als PART Ill: SAN DIEG COUNTY AIR POLLUTION CONTROL DISTRICT APCO: Any YES* answer requires a stamp from APCD 10124 Old Grove Road, San Diego, 921 1 ~comp(@sdcounty.ca.gov ( 58) 586-265 ). *No stamp required if Q1 Yes and 03 Yes .an& 04-06 No]. The following questions are intended to identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions For comprehensive requirements contact APCD Residences are typically exempt. except -those with more than one building~ on the property: single buildlngs with more than four dwelling units: townhomes. condos; mixed•commercial use: deliberate burns; residences forming part of a larger project [+Excludes garages & small outbulidmgs.J 1 2 3. YES NO □ rKI □ IKl D □ Will the project disturb 160 square feet or more of existing building materials? Will any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance Technician? 4 D □ ID (ANSWER ONLY IF QUESTION 3 !S YES} Based on the survey results, wiJI the project disturb any asbestos containing material? Notif1cat1on may be required 10 working days prior to commencing asbestos removal. 5 6 □ □ □ Will the proJect or associated construction equipment emit air contaminants? See the reverse side of this form or APCD facts heel {www sdapcd._9rglinto/tacts/permits.pdf) for typical equipment requiring an APCD permit. (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school boundar Briefly describe business activities. Br"tefly describe proposed project Senior Living Facility for Memory Care FIRE DEPARTMENT OCCUPANCY CLASSIFICATION. BY EXEMPT OR NO FURTHER INFORMATION REQUIRED COUNTY-HMO' APCD · Memory Care Building for Senior Living Nov./ 5 / 2019 Date DATE I I RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY.HMO APCD COUNTY-HMO APCO . A stamp in this box~ exempts businesses from completing or updating a Hazardous Matenals Business Plan. Other perm1tt1ng requirements may still apply County of San Diego-DEH -Hazardous Materials Division INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY Date Nov._ 5. 2019 Business Name Oakmont of Carlsbad Street Address 2_5_4_0 Faraday Avenue Carisba_ci.c <::A __ _ Email Address _____ Dav_id}:itJ_nter_@_oakmontsl.com PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) EJ Check all below that are present at your facility: ------------! --- Acid Cleaning Ink Manufacturing Assembly Laboratory Automotive Repair Machi111ng / Milling Battery Manufacturing Manufacturing Biofuel Manufacturing Membrane Manufacturing Biotech Laboratory (i.e. water filter membranes) Bulk Chemical Storage Metal Casting/ Forming Car Wash Metal Fabrication Chemical Manufacturing Metal Finishing Chemical Purification Electroplating Dry Cleaning Electroless plating Electrical Component Anodizing Manufacturing Coating (i.e. phosphating) Fertilizer Manufacturing Chemical Etching/ Milling Film/ X-ray Processing Printed Circuit Board Food Processing Manufacturing Glass Manufacturing Metal Powders Forming Llndustrial Laund_ry __ SIC Code(s) (if known): Nutritional Supplement/ Vitamin Manufacturing Painting / Finishing Paint Manufacturing Personal Care Products Manufacturing Pesticide Manufacturing / Packaging Pharmaceutical Manufacturing (including precursors) Porcelain Enameling Power Generation Print Shop Research and Development Rubber Manufacturing Semiconductor Manufacturing Soap I Detergent Manufacturing . Waste Treatment/ Storage Brief description of business activities (Production/ Manufacturing Operations): __ NIA __ Description of operations generating wastewater (discharged to sewer, hauled or evaporated): NIA Estimated volume of industrial wastewater to be discharged (gal/ day): NIA List hazardous wastes generated (type/ volume): ___ NIA Date operation began/or will begin at this location: _ _ NIA Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? Yes No If yes, when: ____ NIA __ _ Site Contac vid Hunter Title~"cto~_of Construction ___ _ ~r.:~c:-) :r-rr-;,one No. 707-5_3_5_-3_2_00 _____ _ EW~C)RITY, 6200 Avenida Encinas Carlsbad, CA 92011 (760) 438-3941 FAX: (760) 476-9852 DISCHARGE PERMIT EXEMPT LIST The commercial enterprises listed below are a partial listing of businesses that are exempt from industrial wastewater discharge permitting under normal operating conditions. They are exempt because (a) they discharge no process wastewater (i.e., they only discharge sanitary wastewater with no pollutants exceeding any local limits), and (b) they have no potential to negatively impact the EWPCF or other wastewater treatment plants in t}le ESS. Any questions regarding exemptions should be referred to EWA Source Control staff. x Automobile Detailers Barber/Beauty Shops Business/Sales Offices Carpet/Upholstery Cleaning Services Childcare Facilities Churches Community Centers Consulting Services Contractors Counseling Services Educational Services (no auto repair/film developing) Financial Institutions/Services Fitness Centers Gas Stations (no car wash/auto repair) Grocery Stores (no film developing) Home-based Businesses Hotels/Motels (no laundry) Laundromats Libraries Medical Offices (no x-ray developing) Mortuaries Museums Nail Salons Nursing Homes Office Buildings (no process flow) Optical Services Pest Control Services (no pesticide repackaging for sale) Pet Boarding/Grooming Facilities Postal Services Public Storage Facilities Restaurants/Bars Retail/Wholesale Stores (no auto repair/film developing) Theaters (Movie/Live) " ,--- ~ (city of Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of permits are not required to fill out this form ❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool .,. If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. .,. Details on CAP ordinance requirements are available on the city's website . .,. A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and download the latest form. Project Name/Building Permit No.: Property Address/APN: Applicant Name/Co.: Applicant Address: Contact Phone: C) Ca., 11... ""-0 ""\ ~ L""'-i,\ 'j L,.-~ _'. BP No.: Contact Email: Contact information of person completing this checklist (if different than above): Name: Contact Phone: Company name/address: ~o D J ,t; 5 '-\.5 c; Contact Email: _,Ck."'-. -'-'""2\:-'=-','----'\J'--.::~:=...~\-<--'-----.---,,c;r-:.'--------'°\D\} Applicant Signature: --,/JjA,C:.;L-+'.,h,,L.:::::=---Date: -~\~\....,\r-'~-'-\~\~\~"'--· __ B-50 Page1of6 Revised 08/19 City of Carlsbad Climate Action Plan Consistency Checklist Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For alterations and additions to existing buildings, attach Building Permit Valuation worksheet. Building Permit Valuation (BPV) from worksheet: $ ______ _ D Residential ,,ew construction □ Additions and alterations: □ BPV < $60,000 □ BPV 2' $60,000 □ Electrical service panel upgrade only / BPV 2' $200,000 ~onrjlSidential yl,New construction □ Alterations: □ BPV 2c $200,000 or additions 2c 1,000 square feet □ BPV 2c $1,000,000 □ 2' 2,000 sq. ft. new roof addition 1. Energy Efficiency A high-rise residential building is 4 or more stories, including a Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor area is residential use N/A N/A All residential additions and alterations 1A, 4A 4A 1-2 family dwellings and townhouses with attached garages only •Multi-family dwellings only where interior finishes are removed 1A, 4A• 1B,4A• and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed 1 B, 2B, 3B, 4B and 5 1B, 5 1B, 2B, 5 Building alterations of 2' 75% existing gross floor area 2B, 5 1 B also applies if BPV 2c $200,000 Please refer to Carlsbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CALGreen) for more information when completing ·this section. A. D Residential addition or alteration~ $60,000 building permit valuation. D N/A _________ _ See CMC section 18,30.190. D Exception: Home energy score ~ 7 (attach certification) Year Built Single-family Requirements Multi-family Requirements D Before 1978 Select one: D Duct sealin~ D Attic insulation D Cool roof D Attic insulation D 1978 and later Select one: D Lighting package D Water heating Package D Between 1978 and 1991 Select one: D Duct sealina D Attic insulation D Cool roof D 1992 and later Select one: D Lighting package D Water heating package B.·"ti6. Nonresidential' new construction or alterations~ $200,000 building permit valuation, r or additions~ 1,000 square feet. D N/A Updated 8/15/2019 2 City of Carlsbad Climate Action Plan Consistency Checklist See CMC 18.21.155 and CALGreen Appendix A5, Division A5.2 -Energy Efficiency. A5.203.1.1 Choose one: D .1 Outdoor lighting D .2 Warehouse dock seal doors D .3 Restaurant service water heating (comply with California Energy Code section 140.5, as amended) D N/A _________ _ D .4 Daylight design PAFs D .5 Exhaust air heat recovery A5.203.1.2.1 Choose one as applicable: D .95 Energy budget D N/A A5.211.1" D On-site renewable energy D NIA A5.211.3" D Green power (if offered by local utility provider, 50% minimum renewable sources) D N/A A5.21 .1 Elevators and escalators D N/A D N/A 'Inc udes hotels/motels and high-rise residential buildings "For alterations~ $1,000,000 BPV and affecting > 75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comp~ with CMC 18.30.130 instead. 2. Photovoltaic Systems A. D Residential new construction (for low-rise residential building pennit applications submitted after 1/1/20). Refer to 2019 California Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic requirement (2B below) instead. 2) If project includes installation of an electric heat pump water heater pursuant to CMC 18.30.150(6) (high-rise residential) or 18.30.170(B)(low-rise residential), increase system size by .3kWdc if PV offset option is selected. Floor Plan ID (use additional CFA #d.u. Calculated kWdc' sheets if necessary) Total System Size: kWdc = (CFAx.572) / 1,000 + (1.15 x #d.u.) 'Formula calculation where CFA = conditional floor area, #du= number of dwellings per plan type If proposed system size is less than calculated size, please explain. Exception D D D D kWdc B. D Nonresidential new construction or alterations ~$1,000,000 BPV and affecting ~75% existing floor area, or addition that increases roof area by ~2,000 square feet. Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to high-rise residential and hotel/motel buildings. Choose one of the following methods: □ Gross Floor Area (GFA) Method GFA j1 oV6 I □ If< 1 O,OOOs.f. Enter: 5 kWdc Min. System Size: □ If~ 10,000s.f. calculate: 15 kWdcx(GFA/1O,0OO) •• __ kWdc .. Round building size factor to nearest tenth, and round system size to nearest whole number. □ Time-Dependent Valuation Method Updated 8/15/2019 3 City of Carlsbad Climate Action Plan Consistency Checklist Annual TDV Energy use:"' ______ x .80= Min. system size: _____ kWdc '"Attach calculation documentation using modeling software approved by the California Energy Commission. 3. Water Heating A D Residential and hotel/motel new construction Please refer to CMC sections 18.30.150 and 18.30.170 when completing this section. □ For systems serving individual dwelling units choose one: □ Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) □ Heat pump water heater AND PV system .3 kWdc larger than required in CMG section 18.30.130 (high rise residential hotel/motel) or CA Energy Code section 150.1 (c) 14 (low-rise residential) □ Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher □ Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors □ Exception: □ For systems serving multiple dwelling units, install a central water-heating system with all of the following: □ Gas or propane water heating system □ Recirculation system per CMC 18.30.150(B) (high-rise residential, hotel/motel) or CMG 18.30.170(B) (low- rise residential) □ Solar water heating system that is either: □ .20 solar savings fraction □ .15 solar savings fraction, plus drain water heat recovery eption: Nonresidential new construction Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section. □ Water heating system derives at least 40% of its energy from one of the following (attach documentation): □ Solar-thermal □ Photovoltaics □ Recovered energy □ Water heating system is (choose one): □ Heat pump water heater □ Electric resistance water heater( s) □Solar water heating system with .40 solar savings fraction □ Exception: Updated 8/15/2019 4 City of Carlsbad Climate Action Plan Consistency Checklist 4. Electric Vehicle Charging A D Residential New construction and major alterations• Please refer to Carlsbad Ordinance CMC section 18.21.140 when completing this section. □ One and two-family residential dwelling or townhouse with attached garage: □ One EVSE Ready parking space required □ Exception: □ Multi-family residential □ Exception · Total Parking Spaces EVSE Soaces Proposed Caoable Readv Calculations: Total EVSE spaces= .10 x Total parking (rounded up to nearest whole number) EVSE Installed= Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other= Total EVSE spaces -EVSE Installed (EVSE other may be "Capable," "Ready" or "Installed.") Installed Total 'Major alterations are: (1) for one and two-family dwellings and townhouses ~th attached garages, alterations have a building penmit valuation ~ $60,000 or include an electrical seivice panel upgrade; (2) for multifamily dwellings (three units or more ~thout attached garages), alterations have a building penmit valuation ~ $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing _,,.(ste~s are proposed. ~✓ ---,/ Nonresidential new construction (includes hotels/motels) □ Exception : I. / Total Parking Spaces EVSE Spaces Proposed Capable I Readv I Installed Total I I Calculation· Refer to the table below· Total Number of Parkinq Spaces provided Number of reauired EV Soaces Number of required EVSE Installed Soaces □ 0-9 1 1 □ 10-25 2 1 □ 26-50 4 2 □ 51-75 6 3 □ 76-100 9 5 □ 101-150 12 6 □ 151-200 17 9 □ 201 and over 10 norcent of total 50 percent of Reauired EV Spaces Updated 8/15/2019 5 City of Carlsbad Climate Action Plan Consistency Checklist 5. D Transportation Demand Management (TDM): Nonresidential ONLY An approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT. City staff will use the table below based on your submitted plans to determine whether or nor your permit requires a TOM plan. If TOM is applicable to your permit, staff will contact the applicant to develop a site-specific TOM plan based on the permit details. Acknowledgment: Employee ADT Estimation for Various Commercial Uses Use Office (all), Restaurant Retaib Industrial Manufacturing Warehousin EmpADTfor first 1,000 s.f. 20 11 8 4 4 4 EmpADTI 1000 s.f.1 13 11 4.5 3.5 3 1 1 Unless otherwise noted, rates estimated from /TE Trip Generation Manual, 10thEdition 2 For all office uses, use SANDAG rate of 20 ADT/1,000 sf to calculate employee ADT 3 Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration Sample calculations: Office: 20,450 sf 1. 20,450 sf/ 1000 x 20 = 409 Employee ADT Retail: 9,334 sf 1. First 1,000 sf= 8 ADT 2. 9,334 sf -1,000 sf= 8,334 sf 3. (8,334 sf/ 1,000 x 4.5 + 8 = 46 Em lo ee ADT I acknowledge that the plans submitte•rl.111'a'~f:1 my permit require a TOM plan a Person other than cted for TOM compliance (if applicable): Name (Printed) ____ .-.,_I _,,\1,._~Y\'--'---'-'s'--.QJ-G--_VY\--'_l-y,.,---'-------/. C q't3-V-vt, / .. Phone Number: (Ill I -0 v' v-. Email Address: ____ :f\..J....:1.,_~Y\-'-.:::@_. __c:p_l_f.:...P_5'_u_,_,..._(_, _•\_R._,_C_u_""_' llpdated 8/15/20 I 9 6 , JOEL S. GOLDMAN PARTNER DIRECT DIAL (415) 995-5028 DIRECT FAX {415) 995-3428 E-MAIL jgoldman@hansonbridgett.com September 22, 2014 Dean Mattsson Vice President of Operations Oakmont Management Group 220 Concourse Boulevard Santa Rosa, CA 95403 Re: RCFE Exemption from CRFC Dear Mr. Mattsson: Hanson Bridgett RECEIVED :;ITY OF CARLSBAD oU1LOING DIVISION In our capacity as regulatory legal counsel to Oakmont Management Group, you have asked us to address whether the food services operations in the communities managed by Oakmont are subject to oversight by County Health Departments. All of the senior communities operated by Oakmont are licensed as residential care facilities for the elderly (RCFE) in accordance with California Health and Safety Code Section 1569 et seq. From time to time, a number of counties have attempted to assert jurisdiction to inspect an RCFE operated by one of our clients under the California Retail Food Code (Health and Safety Code Section 117300 et seq.) Please be advised that this law contains an express exemption for RCFEs such as those owned by Oakmont Health and Safety Code Section 113789(c) states: "Food facility does not include any of the following:", and subsection (10) states, "A residential care facility for the elderly, as defined in Section 1569.2." Stated simply, the County has no jurisdiction over the food service operation of any RCFE operated by Oakmont which is subject to pervasive regulation by the Community Care Licensing Division of the Department of Social Services. Please note that when the California Retail Food Code was enacted in 2006 to replace the old CURFFL Statute, there were proposals to do away with the RCFE exemption. These proposals were specifically rejected by the Legislature and the long-standing exemption was retained in Section 113789)c). Therefore, County Health Departments have no jurisdiction over Oakmont's food service operations and your Executive Directors should respectfully decline to allow them to conduct an inspection. If you have any questions regarding this matter, please do not hesitate to contact me. Sincerely, ~ Joel S. Goldman Hanson Bridgett LLP 425 Market Street, 26th Floor, San Francisco, CA 94105 8889353.1 CALIFORNIA RETAIL FOOD CODE Excerpt from CALIFORNIA HEAL TH AND SAFETY CODE PART 7. CALIFORNIA RETAIL FOOD CODE Effective January 1, 2012 California Retail Food Code 113789. Effective January 1, 2012 (Return to Top) (a) "Food facility" means an operation that stores, prepares, packages, serves, vends, or otherwise provides food for human consumption at the retail level, including, but not limited to, the following: (1) An operation where food is consumed on or off the premises, regardless of whether there is a charge for the food. (2) Any place used in conjunction with the operations described in this subdivision, including, but not limited to, storage facilities for food-related utensils. equipment, and materials. (b) "Food facility" includes permanent and nonpermanent food facilities, including, but not limited to, the following: (1) Public and private school cafeterias. (2) Restricted food service facilities. (3) licensed health care facilities. (4) Commissaries. (5) Mobile food facilities. (6) Mobile support units. (7) Temporary food facilities. (8) Vending machines. (9) Certified farmers' markets, for purposes of permitting and enforcement pursuant to Section 114370. (10) Farm stands, for purposes of permitting and enforcement pursuant to Section 114375. (c) "Food facility" does not include any of the following: ( 1 ) A cooperative arrangement wherein no permanent facilities are used for storing or handling food. (2) A private home. (3) A church, private club, or other nonprofit association that gives or sells food to its members and guests, and not to the general public, at an event that occurs not more than three days in any 90-day period. (4) A for-profit entity that gives or sells food at an event that occurs not more than three days in a 90-day period for the benefit of a nonprofit association, if the for-profit entity receives no monetary benefit, other than that resulting from recognition from participating in an event. (5) Premises set aside for wine tasting, as that term is used in Section 23356.1 of the Business and Professions Code and in the regulations adopted pursuant to that section, that comply with Section 118375, regardless of whether there is a charge for the wine tasting, if no other beverage, except for bottles of wine and prepackaged nonpotentially hazardous beverages, is offered for sale for onsite consumption and no food, except for crackers, is served. (6) Premises operated by a producer, selling or offering for sale only whole produce grown by the producer, or shell eggs, or both, provided the sales are conducted on premises controlled by the producer. (7) A commercial food processing plant as defined in Section 111955. (8) A child day care facility, as defined in Section 1596. 750. (9) A community care facility, as defined in Section 1502. (10) A residential care facility for the elderly, as defined in Section 1569.2. ( 11) A residential care facility for the chronically ill, which has the same meaning as a residential care facility, as defined in Section 1568.01. (12) Premises set aside by a beer manufacturer, as defined in Section 25000.2 of the Business and Professions Code, that comply with Section 118375, for the purposes of beer 11 California Retail Food Code Effective January 1, 2012 (Return to Top) (b) At the end of the operating day. Korean rice cakes that have been at room temperature for no more than 24 hours shall be destroyed in a manner approved by the enforcement agency. (c) For purposes of this section, a "Korean rice cake" is defined as a confection that contains rice powder, salt, sugar, various edible seeds, oil, dried beans, nuts, dried fruits, and dried pumpkin. The ingredient shall not include any animal fats or any other products derived from animals. (d) All manufacturers of Korean rice cakes shall place a label on the Korean rice cake as prescribed by Section 111223. 114429.5. (a) Notwithstanding Sections 113996 and 114343, and if permitted by federal law, a food facility may sell Asian rice based noodles that have been kept at room temperature for no more than four hours. (b) Asian rice based noodles that have been kept at room temperature shall be consumed, cooked, or destroyed in a manner approved by the local enforcement agency within four hours of manufacture. (c) At the end of the operating day, Asian rice based noodles that have been kept at room temperature for more than four hours shall be destroyed in a manner approved by the local enforcement agency. (d) For purposes of this section, an "Asian rice based noodle" is defined as a confection that contains rice powder, water, wheat starch, and vegetable cooking oil. The ingredients shall not include any animal fats or any other products derived from animals. An Asian rice based noodle is prepared by using a traditional method that includes cooking by steaming at not less than 130 degrees Fahrenheit, for not less than four minutes. ( e) All manufacturers of Asian rice based noodles shall place a label on the Asian rice based noodle as prescribed by Section 111223. Article 7. Food Facility Food Donations 114432. Any food facility may donate food to a food bank or to any other nonprofit charitable organization for distribution to persons free of charge. 114433. No food facility that donates food as permitted by Section 114432 shall be subject to civil or criminal liability or penalty for violation of any laws, regulations, or ordinances regulating the labeling or packaging of the donated product or, with respect to any other laws, regulations, or ordinances, for a violation occurring after the time of the donation. 114434. The immunities provided in Section 114433 and by Section 1714.25 of the Civil Code are in addition to any other immunities provided by law, including those provided by Chapter 5 (commencing with Section 58501) of Part 1 of Division 21 of the Food and Agricultural Code. Article 8. Child Day Care Facllltles, Community Care Facilities, and Residential Facilities for the Elderly 114437. If and when a specific appropriation is made available, the State Department of Social Services shall develop new regulations regarding food preparation provisions for child 104 California Retail Food Code Effective January 1, 2012 (Return to Top) day care facilities, community care facilities, and residential care facilities for the elderly that would carry out the intent of this part to ensure the health and safety of individuals and that would not adversely affect those facilities that are safely operated. In developing proposed food preparation provisions for child day care facilities, the State Department of Social Services shall consult with the department and the State Department of Education. 105 City of Carlsbad Valuation Worksheet Building Division Memory Care Bldg B SFD and Duplexes $141. 76 $0.00 Residential Additions $169.50 $0.00 Remodels / Lofts $46.51 $0.00 Apartments & Multi-family $126.35 $0.00 Garages/Sunrooms/Solariums $36.98 $0.00 Patio/Porch 6,086 $12.33 $75,040.38 Enclosed Patio $20.03 $0.00 Decks/Balconies/Stairs/ Porte Chachere 1,040 $20.03 $20,831.20 Retaining Walls, concrete,masonry $24.65 $0.00 Pools/Spas-Gunite $52.39 $0.00 Tl/Stores, Offices or Res.Remodel $46.51 $0.00 Tl/Medical, restaurant, H occupancies $64.72 $0.00 Photovoltaic Systems/# of panels $400.00 $0.00 Convalescent Hospitals-Type IIIA 42,749 $152.55 $6,521,359.95 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Fire Sprinkler System 42,749 $4.01 $171,423.49 Air Conditioning -commercial 42,749 $6.47 $276,586.03 Air Conditioning -residential $5.31 $0.00 Fireplace/ concrete, masonry $4,961.73 $0.00 Fireplace/ prefabricated Metal $3,373.05 $0.00 $0.00 $0.00 TOTAL $7,065,241.05 Valuation: $7,065,241 CFD Comm/Res (C/R): C @° Yes (PFF=l.82%) @° No (PFF = 3.5%) Building Fee $15,605.34 Land Use: Plan Check Fee $10,923.74 Density: Strong Motion Fee $1,484.00 Improve. Area: Green Bldg. Stand. Fee $280.00 Fiscal Vear: Green Bldg PC Fee $170.00 Annex. Year: Factor: License Tax/PFF $247,283.44 CREDITS License Tax/PFF (in CFO) $128,587.39 PFF and/or CFD CFO Explanation: Plumbing $62.00 Mechanical $42.00 Electrical $41.00 PERMIT REPORT Revision Permit Print Date: 05/24/2022 ( City of Carlsbad Permit No: PREV2021-0009 Job Address: 2540 FARADAY AVE, CARLSBAD, CA 92008 Status: Closed -Finaled Permit Type: BLDG-Permit Revision Parcel#: 2091200100 Valuation: $0.00 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: OAKMONT OF CARLSBAD Work Class: Commercial Permit Revis Track#: Applied: 01/20/2021 Lot#: Issued: 03/18/2021 Project#: DEV2017-0042 Finaled Close Out: 05/24/2022 Plan#: Construction Type: Orig. Plan Check#: CBC2019-0530 Plan Check#: Inspector: TKers Final Inspection: Description: OAKMONT: MEMORY CARE BUILDING -REVISED TANKED WATER HEATERS TO BE TAN KLESS FEE MANUAL BLDG PLAN CHECK FEE BUILDING PLAN CHECK REVISION ADMIN FEE Property Owner: OAKMONT OF CARLSBAD LLC 2560 FARADAY AVE CARLSBAD, CA 92010 (442) 325-8090 Total Fees: $428.75 Total Payments To Date: $428.75 Balance Due: 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov AMOUNT $393.75 $35.00 $0.00 • f { City of Carlsbad PLAN CHECK REVISION OR DEFERRED SUBMITTAL APPLICATION B-15 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Original Plan Check Number csc2o19~ Plan Revision Number ftse>f~a-;)/-COO°r ProjectAddress 2540 Faraday Ave (Oakmont -Memory Care Building) General scope of Revision/Deferred Submittal: Revised tanked water heaters to be tankless CONTACT INFORMATION: Name Gregg Wanke Phone 707.535.3200 Fax '----------- Address 9240 Old Redwood Hwy, Ste. 200 City Windsor Zip 95492 Email Address gwanke@gallahercompanies.com Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 . Elements revised: Ii] Plans D Calculations D Soils D Energy D Other 2. 3. Describe revisions in detail List page(s) where each revision is shown Revised tanked water heaters to be tankless M2.2. M3.3 P0.2, P0.3 P1 .1, P2.1 P3.1, P4.0, P6.0 Structural Cale Supplement 4. Does this revision, in any way, alter the exterior of the project? D Yes Ii] No 5. Does this revision add ANY new floor areafs)? D Yes !XI No 6. Does this revision affect any fire related issues? D Yes Ii] No 7. Is this a complete set? D Yes Ii] No £S'Signature ~ ~.,c,., Date 1/13/21 1635 Faraday Avenue, Carlsbad, CA 92008 fl:r 760-602-2719 J:.!x: 760-602-8558 f1Dait building@carlsbadca.gov www.carlsbadca.gov January 13, 2021 City of Carlsbad Building Division 1635 Faraday Avenue Carlsbad, CA 92008 Oakmont SL·nior Living RE: Oakmont of Carlsbad -Memory Care Building #CBC2019-0530 To Whom it May Concern, Attached are stamped and signed plans showing a revision that changes the tanked water heaters to tankless water heaters. Plans include mechanical drawings, plumbing drawings, and structural calculations. Please contact me with any questions or comments, or if you need further clarification. Sincerely, ~-~ Gregg Wanke Oakmont Senior living Senior Project Designer (J..1-W ( Jlrl l{cdw1H)d I-J\\'\., )uill' .1(1(1 • \\'i11d-.or ( ,,\ 1!1·-1-(J.1 ,\·L1in ll/) \'-i L1(l(l • L1x /()/ '1 \'1 \.HJ!) ( l,1kn1(11lhL'11i1Jrli\ i11gJ1J111 DATE: MARCH 11, 2021 JURISDICTION: Carlsbad ✓• EsG1I PLAN CHECK#.: PREV2021-0009 (CBC2019-0530_Rev.1) PROJECT ADDRESS: 2540 Faraday Ave. PROJECT NAME: REVISION #1: Oakmont Senior Living □ APPLICANT □ JURIS. SET II ['.8J The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: Byron Hills & Rick Rubalcaba ['.8J EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Bryon Hills & Rick Rubalcaba Telephone#: (208) 258-6154 Date contacted: (by: ) Email: BHills@BHillsArch.com & rickr@apexengineerscoro.com Mail Telephone 0 REMARKS: By: Connor Reuss EsGil Fax In Person 2/2/2021 Enclosures: Approved Set 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 DATE: FEB. 8, 2021 JURISDICTION: Carlsbad ✓• EsG1I PLAN CHECK#.: PREV2021-0009 (CBC2019-0530~Rev.1) PROJECT ADDRESS: 2540 Faraday Ave. PROJECT NAME: REVISION #1: Oakmont Senior Living 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Byron Hills & Rick Rubalcaba 0 EsGil staff did not advise the applicant that the plan check has been completed. ~ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Bryon Hills & Rick Rubalcaba Telephone#: (208) 258-6154 Date contacted: (by: ) Email: BHills@BHillsArch.com & rickr@apexengineerscorp.com Mail Telephone Fax In Person 0 REMARKS: By: Erich A. Kuchar, P.E. Enclosures: Approved Set EsGil 1/22/2021 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK#.: PREV2021-0009 (CBC2019-0530_Rev.1) PREPARED BY: Connor Reuss DATE: FEB. 8, 2021 BUILDING ADDRESS: 2540 Faraday Ave. BUILDING OCCUPANCY: BULDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Air Condilioni~ Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance 1997 UBC Bu1ldin g Permit Fee ... I 1997 UBC Plan Check Fee T»>e of Review: r r Repetitive Fee -. 1 •I Repeats * Based on hourly rate Comments: Complete Review r Other p Hourly EsGilFee Reg. VALUE Mod. r Structural Only 1------__,31 Hrs.@* s1os.oo] ($) , $315.007 Sheet of GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK#.: PREV2021-0009 (CBC2019-0530_Rev.1) PROJECT ADDRESS: 2540 Faraday Ave. DATE PLAN RECEIVED BY ESGIL: 1/22/2021 REVIEWED BY: Connor Reuss FOREWORD (PLEASE READ): DATE REVIEW COMPLETED: FEB.8,2021 This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. • Please make all corrections and submit new complete sets of electronic plans to: THE JURISDICTION'S BUILDING DEPARTMENT. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? □ Yes □ No ) STRUCTURAL COMMENTS PLAN REVIEWER: Erich Kuchar, P.E. SET: I The structural revisions submitted for the water heater skid is approved. PLUMBING COMMENTS PLAN REVIEWER: Connor Reuss SET: I PLUMBING (2019 CALIFORNIA PLUMBING CODE) 1. For the new rooftop water heaters, please provide a complete P&T valve discharge line and condensate waste line design. Clearly show the routing and termination location of each line. NOTE: Each water heater must have its own separate P&T valve discharge. They cannot combine into a common line. CPC 608.5. 2. Calculations/justification to the plans that the x5 tankless to provide enough hot water for the entire building. 3. Several sheets are shown within the improper scale. Fix the shown scale to state 1 /8" = 1' (not ¼" = 1 ') within each sheet provided. 4. For the hot water recirculating loop system, please detail the following: • The installation of an air release valve on the inlet side of the recirculation pump, within 4' of the pump. • A check valve is required between the recirculating pump and the water heating equipment to prevent the hot water from flowing backwards through the recirculation loop. Energy Code 110.3.(c).5.A • A check valve is required on the cold-water supply line between the hot water system and the next closest tee on the cold-water supply line per Energy Code 110.3.(c).5.F (See CPC 608.3 for expansion tank requirements.) • Show the required hose bibb installed between the water heater and isolation valve (after the recirculation pump) per Energy Code 110.3.(c).5.C • Show the required pump isolation valves (both on the inlet and outlet side) for the recirculation pump per Energy Code 110.3.(c).5.D Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Connor Reuss at creuss@esqil.com. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. END OF DOCUMENT DAVID SA NSOTTA Registered Prolessional Engineer In Partners with --.----structural STRUCT URAL EDGE ENGINEERING, P LLC •-• ... ,, .... •-• .... li ... ~..1 •.1 ENG I NE E RING STRUCTURAL EDGE ENGINEERING, PLLC RECEIVED F1:.l::l 2 6 2021 CITY OF CARLSBAD BUILDING DIVISION OAKMONT SENIOR LIVING CARLSBAD MEMORY CARE TANKLESS WATER HEATER ANCHORAGE CA SE PROJECT NO: SE19-041.06 I PREPARED FOR: OAKMONT SENIOR LIVING, LLC 2019 CBC CODE: DATE: SEPTEMBER 16, 2020 P~20U-0000\ 5509 N l ili.::11wood "it. Boi~i:, II) :-n 714 11 208.50 I 2'.2X1) I ww,, ~trm:turnkdl:?c mm 911'5/2020 ATC Hazards by Location · L\TC Hazards by Location Search Information ,a Island Address: 2540 Faraday Ave, Carlsbad, CA 92008, USA ential iabltat... Coordinates: 33.1373764, -117.27242 Elevation: 319 ft Timestamp: 2020-09-16T22:29:56.987Z Hazard Type: Seismic Reference ASCE7-16 Go Document: Risk Category: II Site Class: D-default Basic Parameters Name Value Ss 0.958 S1 0.351 SMs 1.15 SM1 * null Sos 0.767 So1 * null * See Section 11 .4.8 Description MCER ground motion (period=0.2s) MCER ground motion (period=1 .0s) Site-modified spectral acceleration value Site-modified spectral acceleration value Numeric seismic design value at 0.2s SA Numeric seismic design value at 1.0s SA •Additional Information Name Value Description SDC * null Seismic design category Fa 1.2 Site amplification factor at 0.2s Fv * null Site amplification factor at 1.0s CRs 0.904 Coefficient of risk (0.2s) CR1 0.913 Coefficient of risk (1 .0s) PGA 0.418 MCEG peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.501 Site modified peak ground acceleration gle Temecula 0 319 1!.J o'a Carlsbad Cleveland National Forest Anza-Bc Dest State F San Diego 0 Map data ©2020 Google, INEGI https://hazards.atcouncil.org/#/seismic?lat=33.1373764&1ng=-117 .27242&address=2540 Faraday Ave%2C Carlsbad%2C CA 92008%2C USA 1 /2 Seismic Anchorage --~ stru tural •-••r••·••-• .-.1..ait:.1•-. ENGINEERING Properties RACKS FOR WH-1 THRU WH-5 I LENGTH = 70.0 in WIDTH = 30.0 in HEIGHT= 57.0 in TOTAL WT= 560Ib (unit+ rack) SEISMIC DEMAND 0.4 * ap * Sds * WP a = 2.5 F = (1 + 2 * z/h) p p (Rp / Ip) Sds = 0.767 F = p 214.8 lb (ULTIMATE ) w -p-560Ib Fpmax = 687.2 lb (ULTIMATE) R -p-6.0 Fpmin = 128.9 lb (ULTI MATE) I -p -1.0 FD= 214.8 lb I (UL Tl MATE) z/h = 1.0 Fv =185.9 lb !(ULTIMATE) ANCHORAGE Mor= 6121 lb-in MRES = 6271 lb-in USE (4) 3/8" wood lag T/C = NO UPLIFT screws/bolts w/ 3" embed into wood framing (one bolt ea. #Anchors= I 4 total anchor points corner of rack/base rail) VMAX = 541b (ULT) TMAX = 0lb 3/8" Lag Screw V Allow= 140 lb interaction 0.38 TAiiow = 305 lb per in. thread 2" conservatively 5509 N. Glenwood St. Boise, ID 83714 I o: 208.501.2289 I www.structuraledge.com structural ..... ,,, ...... . .-. li.11 l:..I .-. Project Title: Engineer: Project ID: Project Descr: ENGINEERING Printed: 16 SEP 2020, 4:36PM Senior Living\2019 Projects\SE19-041 Carlsbad Memory Care\Calcs\Water Heater Anchorage\Water Heater.ec6 . Software copyright ENERCALC, INC. 1983-2018, Build:10.18.11.30 . Description : Water Heater Mech Well CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set : IBC 201 5 Material Properties Analysis Method : Allowable Stress Design Load Combination JBC 2015 Fb + Fb- 875.0 psi 875.0 psi 600.0 psi 625.0 psi 170.0 psi 425.0 psi E : Modulus of Elasticity Wood Species Wood Grade Beam Bracing : Douglas Fir -Larch : No.2 Fe -Prll Fe -Perp Fv Ft : Beam is Fully Braced against lateral-torsional buckling Ebend-xx 1,300.0ksi Eminbend -xx 4 70 .0 ksi Density 31 .210pcf D(0.14) (0.022) D(0.14) (0.022) D 0.034 Lr 0.04 2xB Span= 7 .0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loads Uniform Load: D = 0.0170, Lr= 0.020 ksf, Tributary Width= 2.0 fl, (Mech Well Uniform) Point Load : D = 0.140, E = 0.0220 k @0.50 ft, (water heater rack) Point Load : D = 0.140, E = 0.0220 k@ 6.0 ft, (water heater rack) DESIGN SUMMARY Maximum Bending Stress Ratio = 0.39!l 1 Maximum Shear Stress Ratio Section used for this span 2x8 Section used for this span fb: Actual = 523.57psi fv : Actual FB : Allowable = 1,312.50psi Fv : Allowable Load Combination +D+Lr+H Load Combination Location of maximum on span = 3.628ft Location of maximum on span Span # where maximum occurs = Span# 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.035 in Ratio = 2393 >=360 Max Upward Transient Deflection 0.000 in Ratio= 0<360 Max Downward Total Deflection 0.085 in Ratio = 991 >=240 Max Upward Total Deflection 0.000 in Ratio= 0 <240 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Segment Length Span# M V Cd CFN c, Cr Cm C t CL M lb +D+H Length = 7 .0 ft 0.318 0.213 0.90 1.200 1.00 1.00 1.00 1.00 1.00 0.33 300.50 +D+L+H 1.200 1.00 1.00 1.00 1.00 1.00 Length = 7 0 ft 0.286 0191 1.00 1.200 100 1.00 1.00 1.00 100 0.33 300.50 +D+Lr+H 1200 1.00 1.00 1.00 1.00 1.00 Length= 7.0 ft 0.399 0.229 1.25 1.200 1.00 1.00 1.00 1.00 1.00 0.57 523.57 +D+S+H 1.200 1.00 1.00 1.00 1.00 1.00 Length = 7 .0 ft 0.249 0166 1.15 1200 1.00 1.00 1.00 1.00 1.00 0.33 300.50 Design OK = 0.229: 1 2x8 = 48.60 psi = 212.50 psi +D+Lr+H = 6.412ft = Span# 1 Shear Values F'b V Iv F'v 0.00 0.00 0.00 0.00 945.00 0.24 32.54 153.00 0.00 0.00 0.00 0.00 1050.00 0.24 32.54 170.00 0.00 0.00 0.00 000 1312.50 0.35 48.60 212.50 0.00 000 0.00 0.00 1207.50 0.24 32.54 195.50 ~~ structural •.•• ,,, •.••.• .... li .. ~..1•11 ENGINEERING Wood Beam Description : Water Heater Mech Well Max Stress Ratios Load Combination Segment Length Span# M V +D+O. 750Lr+0.750L +H Length = 7.0 ft 0.356 0.210 +D+0.750L +O. 750S+H Length = 7.0 ft 0.249 0.166 +D+O 60W+H Length= 7.0 ft 0.179 0.120 +D+0.70E•H Length=?.Oft 0.185 0.127 +D+O. 750Lr+0.750L +0.450W+H Length = 7.0 ft 1 0.278 0.164 +D+0.750L +O. 750S+0.450W+H Length=?.Oft 1 0.179 0.120 +D+O. ?SOL +O 750S+O .5250E+H Length= 7.0 ft 1 0.184 0.125 +0.60D+0.60W+0.60H Length= 7.0 ft 0.107 0.072 +0.60D+0.70E+0.60H Length=7.0ft 1 0.114 0079 Overall Maximum Deflections Load Combination +D•Lr+H Vertical Reactions Load Combination Overall MAXimum Overall MINimum +D+H +D•L+H +O+Lr•H +O+S+H +D+0.750Lr+0.750L +H +D+O .750L +0. 750S+H +D+0.60W+H +D+O.?OE+H •D+O. 750Lr +0 .750L +O .450W+H +D+0.750L +0. 750S+0.450W+H +O+O. ?SOL +O. 750S+0.5250E+H +0.600+0.60W+0.60H +0.600+0.70E+0.60H DOnly Lr Only LOnly SOnly WOnly EOnly HOnly Span Project Title: Engineer: Project ID: Project Descr: Printed: 16 SEP 2020, 4:36PM Senior Living\2019 Projects\SE19-041 Ca~sbad Memory Care\Calcs\Water Healer Anchorage\Water Heater.ec6 . Software copyright ENERCALC, INC. 1983-2018, Build:10.18.11.30 . Moment Values Shear Values Cct CFN c, Cr Cm Ct CL M fb F'b V fv F'v 1.200 1.00 1.00 1.00 1.00 100 0.00 000 0.00 0.00 1.25 1.200 1.00 1.00 1.00 1.00 1.00 0.51 467.73 1312.50 0.32 44.59 212.50 1.200 1.00 1.00 1.00 1.00 1.00 0.00 000 0.00 0.00 1.15 1.200 1.00 1.00 1.00 1.00 1.00 0.33 300.50 1207.50 0.24 32.54 195.50 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1.60 1.200 1.00 1.00 1.00 1.00 1.00 0.33 300.50 1680.00 0.24 32.54 272.00 1.200 100 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1.60 1.200 1.00 1.00 1.00 1.00 1.00 0.34 311.34 1680.00 0.25 34.51 272.00 1.200 1.00 1.00 1.00 1.00 1.00 000 0.00 0.00 000 1.60 1.200 1.00 1.00 1.00 1.00 1.00 0.51 467.73 1680.00 0.32 44.59 272.00 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1.60 1.200 1.00 1.00 1.00 1.00 1.00 0.33 300.50 1680.00 0.24 32.54 272.00 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 000 1.60 1.200 1.00 1.00 1.00 1.00 1.00 0.34 308.62 1680.00 0.25 34.02 272.00 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1.60 1.200 1.00 1.00 1.00 1.00 1.00 0.20 180.30 1680.00 0.14 19.52 272.00 1.200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1.60 1.200 1.00 1.00 1.00 1.00 1.00 0.21 191.15 1680.00 0.16 21.49 272.00 Max."." Deft Loca~on in Span Load Combinafion Max."+" Defi Locafion in Span 0.0847 3.551 0.0000 0.000 Support nota~on : Far left is #1 Values in KIPS Support 1 Support2 0.417 0.397 0.024 0.020 0.277 0.257 0277 0.257 0.417 0.397 0.277 0.257 0.382 0.362 0277 0.257 0.277 0.257 0.294 0.272 0.382 0.362 0.277 0.257 0.290 0.268 0.166 0.154 0.183 0.169 0.277 0.257 0.140 0.140 0.024 WATER HE ATER SC HE DU LE-GAS 111-j-1 thru tiQ1ES;_ NORITZ 41NCCl 99CDV SET TO 110'f, 94,: EFF. > 1. WH-1 lHRU 'M-t-5 SHALL BE INSTALLED ON A NORTIZ#CR60-f S-5-NG ALUMINUM MOUNTING RACK 'MlH OPTIONAL fLOOR STAND. 74"Lx30"Dx57"H. TOTAL WEIGHT • 56 LBS INCLUDING HEATERS. > 2. HEATERS SHALL BE PROVIDED W/INT-20 CONDENSATE NEUlRAUZER, #VC-6 OUTDOOR VENT CAP & NWCC ADAPTER & 'M-Fl ADAPTER. 0 1 I -=--=--=-1-= -ilil---+-,-----iH+' ~·I ~ ffi - CR60-FS-5 Specifications BTU and Flow Rates for NCC199CDV (GQ-C3260WZ-FF US) Number of Tankless Water Heaters 5 Max. Hot Water Capacity @ 30°F rise (GPM) 55.5 Max. Hot Water Capacity@ 70°F rise (GPM) 28.0 Minimum (Btuh) 18,000 Maximum (Btuh) 999,500 Model and Rack Specifications Model Number CR60-FS-5 Tankless Water Heater Model NCC199CDV Rack Frame Dimensions (in) 74.0 (L) x 30.0(D) x 56.75 (H) Weight -Fully Assembled (lbs) 560 Shipping Weight -Fully Assembled (lbs) 1160 Frame Material Aluminum Frame Color Aluminum Water & Gas Pipe Connections Hot Water Manifold Pipe Material Copper Cold Water Manifold Pipe Material Copper Gas Manifold Pipe Material Black Iron Condensate Drain Manifold Pipe Material Schedule 40 PVC Hot Water Manifold Pipe Diameter (in) 2 Cold Water Manifold Pipe Diameter (in) 2 Gas Manifold Pipe Diameter (in) 2 Condensate Dra in Manifold Pipe Diameter (in) 3/4 Electrical Requirements Voltage 120VAC (60 Hz) Maximum Current (Amps) 20 34 CR60-IM.v0429.4 5 Unit Drawing Illustration/ Dimensions co ,.,; Lr) 0 M ,- o; T' J ~ 5. 1 12. 2 34 ,. 18. 1 *All Units are in inches 55. 7 21. 8 USE (4) 3/8" wood lag screws/bolts w/ 3" embed into wood framing (one bolt ea. corner of rack/base rail) IOHOJ a m aT 5. 1 ~ L5.1 «Top» 74 21. 8 3/4" CONDENSATION, PVC 2" COLD WATER, Copper Lr) c--i °' -co «Front» 35 2" GAS, Black Iron 2" HOT Water, Copper -a, -' co - 5. 1 9.5 7. 4 9. 4 «Right» CR60-IM.v0429.4 I ~UNORITZ Commercial Sizing Recommendation The Simple Comforts of Ufe Project Name joakmont Carlsbad NOT Memory Care Project#~==============~ Location Bid Date~=============~ APPLICATION INFO: Job Type Senior/Assisted Living Gas Type NG Indoor or Outdoor Outdoor Elevation from Sea Level (Ft) less than 2000 FIXTURE TYPE FIXTURE UNITS ZONES Dwellings/Common Shower/tub 1.50 115 Private Lav 0.75 115 Kitchen Sink 0.75 95 Residential Dishwasher 1.50 95 Public Lav 1.00 19 Sitz Bath 3.00 0 Ward Shower 2.50 Utility Sink 1.50 12 Laundry Sink 1.50 4 Clotheswasher (20 lb) 1.47 18 Clotheswasher (SO lb) 3.68 Clotheswasher (60 lb) 4.41 Hand Sink 1.50 Bar Sink 2.50 Prep Sink 2.00 Slop Sink 2.00 Pre-Rinse 2.50 Commercial Dishwasher 2.50 Kitchen Sink 3.00 1-Comp Sink 2.50 2·Comp Sink 3.50 3-Comp Sink 5.50 Mop sink 2.00 3 Hose Reel 2.50 1 TOTAL FIXTURE UNITS 550.47 Peak Demand (GPM) 43.0 Diversity 100% Prepared By Architech Engineer Contractor Wholesaler Kitchen 5 2 1 2 2 1 1 0 1 2 36.50 16.0 75% OPTION: TAN KLESS WITHOUT STORAGE MAX INPUT ZONE RACK MODEL UEF / TE TOTAL QTY HEATERS (BTU/HR) CR60·FS-4-NG Dwellings/ Common + 97%/98% 9 1,799,100 CR60·FS-5-NG Kitchen CR60-FS-4-NG 97%/98% 4 799,600 INCLUDED COMMERCIAL RACK ACCESSORIES OPTIONAL ACCESSORIES Part Description Part# Part Description Part# System Controller SC-401-6M Condensate Neutralizer NT-20A Isolation Valve IK-WV-200-1-TH Outdoor Vent Cap VC-6 WIFi Adapter NWCC-ADAPTER I I I I I RECEIVED FEB 2 6 2021 CITY OF CARLSBAD BUILDING DIVISION FLOWRATE@ Ground Water Setpomt Temp TEMP RISE (GPM) Temp (Deg F) (Deg F) 47.0 65 140 20.9 65 140 GENERAL NOTES WATER FIXTURE CAI.CULATION WATER FIXl\lRE CALCULATION (KITCHEN STMeOl HXTUUUNl'1 QUANTln fOTA&. CW UNJTS TOl Al HW UHITS snoeoo. FIJITUMUIHU QUAAITm TOlALCWUMU TOTAl tN/UMU WATUCLOSfT 15 I It 4H j 0 WATCRCUJVT 7.S 0 0 0 LAV.\T~Y I t 19 19 19 HAH05.IN< l s s s HK I II 24 ,. KITCHEN SINIC 2 1 ,. 14 MOflSlhlC J ) ' I 9 MOPSINk . l l I ) OOfHE.SWAVtUI • II n n DISIIWA.Sttl-• I • • lAUHCMrt'S4NK 2 ' • I ----,_ j LNJN00lY5,INt 2 0 0 0 KYOftOTU8 ' 0 0 0 HYOIIOl\Ja ~ • 0 0 ,-• HOS(IIH 25 I 13 14.S 2S ltOS( 1111 ! H 2 s s ~TH GROUP ' 115 51' 111 "s UIUNAL 2 0 0 0 kllCHf'N GROUP ' " '"° 190 IATliGROUP . s 0 . 0 • -- rt.OOR OblN 0 t ) 0 0 fLOOlDRA.N I • 0 0 0 (lOOA SINJC 0 -I 2 0 0 H.OOIII SfNI( 0 0 0 0 l(ITCH[N 31 • TOTAL J1 JI TOTAl -----,u CW MAXIMUM llOW PU CK JAnUIOIJ( "I JO.SGPM CW MAJUMUM ROW ,u: C,C 106.S GPM NW MA.lllMUM fLOW P'£ll CPC tAPPlN~ JO.SGPM HW MAXIMUM llOW PU C,C 144~ GPM r·XT\Jflr UHIUAltl fU(N rAOMCHAPTEA 6 rnrru1u UNITS AA(TM("' FflOM C'JWTH 6 --------- DISCLAIMER This si2ing is meant to be used as a reference guide only. This sizing operates under the assumption that all information provided by the customer is accurate and complete. It does not replace a professionally engineered job. Noritz America does not infer that the sizing provided is a complete solution. The contractor/engineer is responsible for determining all of the necessary components for a fully functional system. The sizing does not imply compliance with all local building codes. It is the responsibility of the engineer/contractor to ensure that all building codes are met. Consult with your local building official before installation. PERMIT REPORT Revision Permit Print Date: 05/24/2022 Job Address: 2540 FARADAY AVE, CARLSBAD, CA 92008 (city of Carlsbad Permit No: PREV2021-0017 Status: Closed -Expired Permit Type: BLDG-Permit Revision Work Class: Parcel#: 2091200100 Track#: Commercial Permit Revis Applied: 02/02/2021 Valuation: $0.00 Lot#: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: OAKMONT OF CARLSBAD Project#: DEV2017-0042 Plan#: Construction Type: Orig. Plan Check#: CBC2019-0530 Plan Check#: Description: OAKMONT: DEFERRED TRUSS FOR MEMORY CARE BUILDING FEE Total Fees: Property Owner: OAKMONT OF CARLSBAD LLC 2560 FARADAY AVE CARLSBAD, CA 92010 (442) 325-8090 Total Payments To Date: Issued: Finaled Close Out: Inspector: TKers Final Inspection: AMOUNT Balance Due: 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov PERMIT REPORT Revision Permit Print Date: 05/24/2022 Job Address: 2540 FARADAY AVE, CARLSBAD, CA 92008 (city of Carlsbad Permit No: PREV2021-0032 Status: Closed -Finaled Permit Type: BLDG-Permit Revision Work Class: Commercial Permit Revis Parcel#: 2091200100 Track#: Applied: 03/01/2021 Valuation: $7,065,241.05 Lot#: Issued: 03/31/2021 Occupancy Group: Project#: DEV2017-0042 Finaled Close Out: 05/24/2022 #of Dwelling Units: Bedrooms: Bathrooms: ProjectTitle: OAKMONT OF CARLSBAD Plan#: Construction Type: Orig. Plan Check#: CBC2019-0530 Plan Check#: Description: OAKMONT: ADDITION OF COMMON AREA TOILET TO 2ND FLOOR FEE BUILDING PLAN CHECK REVISION ADMIN FEE MANUAL BLDG PLAN CHECK FEE Property Owner: OAKMONT OF CARLSBAD LLC 2560 FARADAY AVE CARLSBAD, CA 92010 (442) 325-8090 Total Fees: $428. 75 Total Payments To Date: $428.75 Inspector: TKers Final Inspection: Balance Due: AMOUNT $35.00 $393.75 $0.00 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov (cicyof Carlsbad PLAN CHECK REVISION OR DEFERRED SUBMITTAL APPLICATION B-15 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Original Plan Check Number CBC2019-0530 Plan Revision Number _D_e_lta_#_5 ____ _ ProjectAddress 2540 Faraday Avenue, Carlsbad, CA General Scope of Revision/Deferred Submittal: Addition of common area toilet to the second floor CONTACT INFORMATION: Name Marie Cooper Phone 661-312-9821 ________ Fax ________ _ Address 43320 Yale Court City Lancaster Zip 93536 Email Address mcooper@OSLconstruction.com Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 . Elements revised: [j] Plans D Calculations D Soils D Energy D Other 2. 3. Describe revisions in detail List page(s) where each revision is shown Architectural pages changed A2.3, A2.6.3, A4.4 Electrical Pages changed E2.2, E3.2, E3.6 Mechanical Pages changed M2.2, M2.3, M3.3 Plumbing Pages Changed P2.1, P3.1, P4.0, P5.1 4. Does this revision, in any way, alter the exterior of the project? D Yes Ii] No 5. Does this revision add ANY new floor area(s)? D Yes D No 6. Does this revision affect any fire related issues? D Yes Ii] No 7. Is this a complete set? D Yes [j] No M • C Digitally signed by Marie Cooper 02/25/21 £$'Signature ane ooper Date:2021.03.0108:13:56-08'00' Date --------- 1635 Faraday Avenue, Carlsbad, CA 92008 Ph: 760-602-2719 Ea/I: 760-602-8558 Email building@carlsbadca.gov www.carlsbadca.gov DATE: 3-25-2021 JURISDICTION: Carlsbad ✓• EsG1I PLAN CHECK#.: CBC2019-0530 (PREV2021-0032) PROJECT ADDRESS: 2540 Faraday Ave. 0 APPLICANT 0 JURIS. SETI PROJECT NAME: REVISION: Oakmont Senior Living: Added Common Bathroom at Second Level & Other Relevant Changes [g] The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The check list transmitted herewith is for your information. The plans are being held at EsGil , until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: [g] EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Email: Mail Telephone Fax In Person 0 REMARKS: By: Erich A. Kuchar, P.E. EsGil 3-4-2021 l::nclosures: Approved Set staying at tsGil for other submittals 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 [DO NOT PAY -THIS IS NOT AN INVOICE} VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK#.: CBC2019-0530 (PREV2021-0032) PREPARED BY: Erich A. Kuchar, P.E. BUILDING ADDRESS: 2540 Faraday Ave. BUILDING OCCUPANCY: BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Revision Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance 1 7 UBC Buildin Permit Fee 99 g .... 1997 UBC Plan Check Fee ...- Type of Review: □ Complete Review D Repetitive Fee .., · Repeats • Based on hourly rate Comments: D Other [J Hourly EsGil Fee DATE: 3-25-2021 Reg. VALUE ($) Mod. D Structural Only 31 Hrs.@• ~=====$=1 o=s=.o:o $31s.001 Sheet of February 24, 2021 City of Carlsbad Building Division 1635 Faraday Avenue Carlsbad, CA 92008 -Oakmont Senior Living RE: Oakmont of Carlsbad -Memory Care Building #CBC2019-0530 To Whom it May Concern, Attached are stamped and signed plans showing a revision that adds a common area toilet to the second floor. Plans include architectural, electrical, mechanical and plumbing drawings. The architectural drawings submitted are A2.3, A2.6.3 and A4.4 and are clouded with delta #8. The electrical, mechanical and plumbing drawings submitted are E2.2, E3.2, E3.6, M2.2, M2.3, M3.3, P2.1, P3.1, P4.0, P4.1 and PS.1 and are clouded with delta #5. Please contact me with any questions or comments, or if you need further clarification. Sincerely, ~-~ Gregg Wanke Oakmont Senior Living Senior Project Designer 9140 Old Redwood Hv,1y., Suite 200 • VVlndsor, CA q~4q2 Main ~'07-'l.Vi-Q(H) • L1x 707-535-1299 0,1 kmontsen iorl iv i ng. l om