HomeMy WebLinkAbout2285 RUTHERFORD RD; ; CBC2021-0486; PermitPERMIT REPORT (city of Carlsbad Commercial Permit Print Date: 05/09/2022 Permit No: CBC2021~0486 Job Address: 2285 RUTHERFORD RD, CARLSBAD, CA 92008-8815 Status: Closed -Finaled Permit Type: BLDG-Commercial Work Class: Tenant Improvement Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: $0.00 Track#: Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Description: QUI DEL: HIGH PILE STORAGE RACKING Applicant: 548 GROUP TIM FREE Property Owner: QUID EL CORPORATION 9975 SUMMERS RIDGE RD 555 N EL CAMINO REAL, # A299 SAN CLEMENTE, CA 92672-6740-0RANGE (949) 861-1881 SAN DIEGO, CA 92121-2997-SAN DIEGO (8S8) 302-0750 FEE BUILDING PLAN CHECK STORAGE RACKS> 8 FT HIGH BUILDING PLAN REVIEW-MINOR PROJECTS (PLN) SB14 73 -GREEN BUILDING STATE STANDARDS FEE FIRE High Piled Storage Total Fees: $1,723.65 Total Payments To Date: $1,723.65 Applied: 12/20/2021 Issued: 02/01/2022 Finaled Close Out: 05/09/2022 Inspector: Final Inspection: Contractor: 548 GROUP INC TKers 02/24/2022 555 N EL CAMINO REAL, #STEA 299 SAN CLEMENTE, CA 92672-6740-0RANGE (949) 861-1881 Balance Due: AMOUNT $312.65 $481.00 $98.00 $1.00 $831.00 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager tor processing in accordance with Carlsbad Municipal Code Section 3.32.030. Fallure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov (City of Carlsbad Job Address 2285 Rutherford Road COMMERCIAL BUILDING PERMIT APPLICATION B-2 Plan Check Est. Value PC Deposit Date Suite: APN: 2120620800 , _____ , Tenant Name:_a_u_id_e_r _____________ _ Lot#: Year Built: Unknown Occupancy:_s_-1 ___ _ IIIA Dl:!J Dc::J Construction Type_· _-____ Fire Sprinklers: yes no A/C: yes no BRIEF DESCRIPTION OF WORK: Installation of pref~bricated high pile racking inside caged area outside of warehouse. 20 LP OF IZ4CJ( . D Addition/New: ___________ New SF and Use, ___________ New SF and Use, ---Deck SF, Patio Cover SF (not including flatwork) ~ Tenant lmprovement:_7_5 ____ SF, Existing Use Warehouse Proposed Use Warehouse _____ SF, Existing Use ______ Proposed Use ______ _ D Pool/Spa: _____ SF Additional Gas or Electrica I Features? ____________ _ DD DD DD D Solar: ___ KW, ___ Modules, ___ Mounted, Tilt: Yes/ No, RMA: Yes/ No, Panel Upgrade: Yes/ No D Plumbing/Mechanical/Electrical Only: -------------------------- D Other: This permit is to be issued in the name of the Property Owner as Owner-Builder, licensed contractor or Authorized Agent of the owner or contractor. The person listed as the Applicant below will be the main point of contact throughout the permit process. PROPERTY OWNER APPLICANT 0 PROPERTY OWNERS AUTHORIZED AGENT APPLICANT 0 Name: Quidel Name: 548 Group, Inc. -----------------Address:2285 Rutherford Road Address: 555 North El Camino Real, #A299 City: Carlsbad State:._c_A __ Zip: 92008 City: San Clemente State:._C_A __ ,Zip: 92672 Phone: 949-485-1711 Phone: 858-552-7925 Email: Logan@548group.com Email: Logan@548group.com DESIGN PROFESSIONAL APPLICANT 0 CONTRACTOR BUSINESS APPLICANT [jJ Name: Structural Engineering & Design, Inc. Name: 548 Group, Inc, Address: 1815 Wright Avenue Address: 555 North El Camino Real, #A299 City: La Verne State: CA Zip: 91750 City: San Clemente State: CA Zip:,_9_2_6_7_2 ___ _ Phone: 909-596-1351 Phone: 949-861-1881 Email: bob@sedinc.com Email: tim@548group.com Architect State License: C26608 State License: 1039588 Bus. License: TBD -----------·------------- 1635 Faraday Ave Carlsbad, CA 92008 8-2 Ph: 760-602-2719 Fax: 760-602-8558 Page 1 of 2 Email: Building@carlsbadca.gov Rev. 08/20 IDENTIFY WHO Will PERFORM THE WORK BY COMPLETING (OPTION A) OR (OPTION 8) BELOW: (OPTION A): LICENSED CONTRACTOR DECLARATION: I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. I also affirm under penalty of perjury one of the folfowing declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. Policy No. ----------~-------------- 1!!!!!11 have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued, My workers' compensation insurance carrier and policy number are: Insurance Company Name: State Compensation Insurance Fund Policy No. 9274220-2020 Expiration Date: _o_41_o_s1_20_2_2 _________________ _ 0 Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 {i) Civil Code). Lender's Name:. _____________________ lender's Address: ____________________ _ CONTRACTOR PRINT: Timothy P. Free SIGN: _ ___._/ t,J,n.,d--~--~-~ __ DATE: 12.15.21 {OPTION B): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: DI, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). DI am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason: 0 "Owner Builder acknowledgement and verification form" has been Iii led out, signed and attached to th is application. Proof of identification attached. 0 Owners "Authorized Agentform" has been filled out, signed and attached to this application giving the agent authority to obtain the permit on the owner' behalf. Proof of Identification attached. By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed contractors./ understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application is submitted or at the following Web site: http://www.leginfo.ca.gov/colow.htmf. OWNER PRINT: ____________ SIGN: _________ DATE: ______ _ APPLICANT CERTIFICATION: SIGNATURE REQUIRED AT THE TIME OF SUBMITTAL By my signature below, I certify that: I am the property owner or Stote of California Licensed Contractor or authorized to act on the property owner or contractor's behalf I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SA VE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL UABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. Logan Manning APPLICANT PRINT: _________ _ SIGN: ue~ DATE: 12.15.21 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-2 Page 2 of 2 Rev. 08/20 Building Permit Inspection History Finaled (city of Carlsbad " ~ ' ·"" [,;. PERMIT INSPECTION HISTORY for {CBC2021-0486} Permit Type: BLDG-Commercial Application Date: 12/20/2021 Owner: QUIDEL CORPORATION Work Class: Tenant Improvement Issue Date: 02/01/2022 Subdivision: Status: Closed -Finaled Expiration Date: 08/23/2022 Address: 2285 RUTHERFORD RD IVR Number: 37700 CARLSBAD, CA 92008-8815 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 02/18/2022 02/18/2022 BLDG-Fire Final 176894-2022 Passed Felix Salcedo Complete Checklist Item COMMENTS Passed FIRE-Building Final Yes 02/24(2022 02/24(2022 BLDG-14 177100-2022 Passed Tim Kersch Complete FramefSteel/Bolting/We !ding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Final Inspection 177101-2022 Passed Tim Kersch Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-Structural Final No Monday, May 9, 2022 Page 1 of 1 • nv INTERWESl DATE: 1/5/2022 JURISDICTION: City of Carlsbad PLAN CHECK#.: CB-CBC2021-0486 PROJECT ADDRESS: 2285 Rutherford Rd. SETI PROJECT NAME: Quidel High Pile Storage Rack □ APPLICANT □ JURIS. L8'] The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The check list transmitted herewith is for the applicant's information. The plans are being held at lnterwest until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to the jurisdiction at L8'J lnterwest staff did not advise the applicant that the plan check has been completed. D lnterwest staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: Mail Telephone (by: Telephone#: ) Email: Fax In Person L8'J REMARKS: City to field verify that the path of travel from the handicapped parking space to the rack area and the restroom serving the rack area comply with all the current disabled access requirements. By: David Yao lnterwest 12/21/2021 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 City of Carlsbad CB-CBC2021-0486 1/5/2022 [DO NOT PAY-THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: David Yao BUILDING ADDRESS: 2285 Rutherford Rd. BUILDING OCCUPANCY: BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier racks Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: 0 Complete Review D Repetitive Fee ~: Repeats Comments: □ Other 0 Hourly EsGil Fee PLAN CHECK#.: CB-CBC2021-0486 DATE: 1/5/2022 Reg. VALUE ($) Mod. D Structural Only $312.651 Sheet of Structural Engineering $ Design, Inc 1815 Wright Ave La Verne, Ca. 91750 Tel: 909-596-1351 Fax: 909-596-7186 Prqject Name : QUIDEL Prqject Number: 21-1206-2 Date : 12/09/21 Street Address: 2285 RUTHERFORD RD City/State : CARLSBAD, CA 9200t. Scope of Work : STORAGE RACK 12/14/21 CBC2021-0486 2285 RUTHERFORD RD QUIDEL: HIGH PILE STORAGE RACKING >-1--0 12/20/2021 CBC2021-0486 Structural • Engineering & Design Inc. 1s15 Wrigbt Aye La Verne. CA 91750 Tel: 909 596,1351 fax: 909,596.7186 By: Bobs Project: Quldel Project#: 21-1206-2 TABLE OF CONTENTS Title Page ..................... , ... , ....... , ........................................................... , ... ,............ 1 Table of Contents................................................................................................... 2 Design Data and Definition of Components ........... ...... .... ......... ................... ..... .... 3 Critical Configuration ... .. . . . . ... . . . . . . . . . . . . . . . . . . .. . ... ... ... . ... .. . . . . . . . . . . . .. . .. . . . . .. ............... .... .... 4 Seismic Loads .............. .... .. . .... ... .. . .. . .. . .. .. .. .. .. .. ... ............ ... . .. .. .. .. ... .. .. .. .. . .. . ... .. ... ... . 5 to 6 Column .................................................................................................................. 7 Beam and Connector . .. ..... .. .. ... .... ..... .... .... .. ....................... .... .. . .. .. .. .. .. .. .. .. .. .. . .... ... 8 to 9 Bracing ................................................................ ,................................................. 10 Anchors ................................................................................................................. 11 Base Plate ............... ,............................................................................................. 12 Slab on Grade ........................................................................................................ 13 I Other Configurations ............................................................................................. 14 type c eielc:ct-qu1del.xls Fage 0( of / 1/ 12/8/2021 Structural Engineering & Design Inc. 1815 Wright Aye La Verne, CA 91760 Tel: 909,596,1351 fax: 909 696,7186 By: Bob S Project: Quidel Project#: 21-1206-2 Design Data 1) The analyses herein conforms to the requirements of the: 2018 /BC Section 2209 2019 CBC Section 2209 ANSI MH 16.1-2012 Specfticatfons for the Design of Industrial Steel Storage Racks "2012 RMI Rack Design Manual" ASCE 7-16, section 15.5.J 2) Transverse braced frame steel conforms to ASTM A570, Gr.55, with minimum strength, Fy=55 ksi Longitudinal ~ame beam and connector steel conforms to ASTM A570, Gr.55, with minimum yield, Fy=55 ksl All other steel conforms to ASTM A36, Gr. 36 with minimum yield, Fy= 36 ksl 3) Anchor bolts shall be provided by Installer per ICC reference on plans and calculatlons herein. 4) All welds shall conform to AWS procedures, utlllzlng E70xx electrodes or slmllar. All such welds shall be performed In shop, with no field welding allowed other than those supervised by a licensed deputy Inspector. 5) The existing slab on grade ts 4.75" thick with minimum 2511 psi compressive strength. Allowable Soll bearing capacity Is 750 psf. The design of the existing slab Is by others. 6) Load combinations for rack components correspond to 2012 RMI Section 2.1 for ASD level load criteria Petloltloo ot components A BPnt Ytew1 :l)qwn Ailk (l,ang1ty,dln;a Aw type c ~loct-qu,del.xl5 8ue1:tateand Anchors Sedlo'Q A, Op& Ah1e (T@l!M1"511!) fnme Paqe 3 of/ l/ ~· IQ-acne llagoMI 9'ace 12/8/2021 Structural Engineering & Design Inc. 1815 Wright Aye La Verne. CA91750 Tel· 909 596.1351 Fax: 909 596 7186 By: Bob S Project: Quldel Project#: 21-1206-2 Configuration &. Summary: Type C SelectJve Rack -96" Bay T 44" 96" + 46" t 6" I ' Seismic Criteria Ssc:0.968, Fa=l.113 Component Column Column & Backer Beam Beam Connector Brace-Horizontal Brace-Diagonal Base Plate Anchor Slab & Soll Level T 48" 00" t 36" l ,_____... **RACK COLUMN REACTIONS ASOLOAOS AXIAL OL"" 75 lb AXIAL LL= 6,000 lb SEISMIC AXIAL Ps::::+/-2,406 lb BASE MOMENT= 0 In-lb ,-r -oo· ----;f } 42" -f # Bm Lvls Frame Depth Frame Height # Dia onals Beam Length Frame Type 3 42 In 96.0 In 2 96In Single Row Description STRESS Fy=55 ksl Hannibal IF3014-3x3x14ga P==4050 lb, M==6940 ln·lb 0.29-0K None None None NIA FY=SS ksl HMH 41160/4.125" Face x 0.057" thk Lu=96 In I capacity: 5075 lb/pr 0.79-0K Fv=55 ksl Lvl 1: 3 pin OK I Mconn=S363 In-lb I Mcap==12691 ln·lb 0.42-0K Fy=55 ksl Hannibal 1-l/2x1-1/2xl6ga 0.2-OK Fy=55 ksl Hannibal 1-l/2xl-l/2xl6ga 0.31-0K Fy=36 ksl 8x5x3/8 I Fixity= 0 In-lb 0.75-OK 1 oer Base 0.5'' x 2" Embed HILTI KWIKBOLT TZ ESR 1917 Inspection Reqd (Net Selsmlc Upllft=514 lb) 0.683-0K 4.75" thk x 2511 psi slab on grade. 750 psf Soll Bearing Pressure 0.79-0K Column Column Conn. Beam j Load** Per Level • Beam Spca Brace I Story Force . I Story Force Transv L1,>nglt, _ AxlaJ .I Moment I MomenL .Connector 1 2 3 4,000 lb 4,000 lb 4,000 lb 6.0 In 46.0 In 44.0 In ** Load defined as pmduct weight per pair of beams type c e,ele:ct-qu1de:l.xb 36.0 In 48.0 In 57 lb 4971b 917Ib Total: 1,471 lb 25 lb 212 lb 392Ib 628Ib Page '/ of /l.j 6,075 lb 4,050 lb 2,025 lb 942 "# 6,940 "# 4,305 "# 5,363 "# 6,540 ''# 4,111 "# 3 pin OK 3 pin OK 3 pin OK I 2/812021 Structural Engineering & Design Inc. 1815 Weight Ave La Verne. CA 91750 Tel: 909 596 1351 fax· 909.596 7186 By: Bob S Project: Quidel Project#: 21 -1206-2 Seismic Forces Configuration: Type C Selective Rack• 96" Bay latl!ral analyal1 ,. pe,formed with regard to the requirements of the 2012 RMI ANSI MH 16.1-2012 SBCl 2.6 1k ASCE 7·16 sec 15.5.3 Transverse (Cross Alsle} Seismic Load V= Cs*Ip*Ws=Cs*Ip*(0.67*P*Prf+D) Csl= Sds/R = 0.1796 Cs2= 0.044*Sds = 0.0316 Cs3= O.S*S1/R = 0.0443 CS-max= 0.1796 Dase Shear Coeff.,Cs= 0.1796 Level 1 2 3 PRODUCT LOAD P 4,000 lb 4,000 lb 4,000 lb Cs-max * Ip= 0.1796 Vm1n= 0.015 Eff Base Shear=CS= 0.1796 .llllll==.ufuln P*0.67*PRF1 2,680 lb 2,680 lb 2,680 lb Wsr: (0.67*PLRF1 * PL)+DL (RMI 2.6.2) = 8,190 lb Vtransv=Vt= 0.1796 * (150 lb+ 8040 lb) Etransverse= 1,471 lb Umlt State# Level Tran-seismic sheilr per upright DL hi wl*hi 50 lb 6 In 16,380 50 lb 52 In 141,960 50 lb 96 In 262,080 Ss= 0.968 S1= 0.354 Fa= 1.113 Fv= 1.950 Sds=2/3*Ss*Fa= 0.718 Sd1=2/3*S1 *Fv= 0.460 ca=0.4*2/3*5s*Fa= 0.2873 (Transverse, Braced Frame Dir.) R= 4.0 Ip= 1.0 PRFf= ~~~~mt'?:lll Pallet Helght==hp= 48.0 In DL per Beam Lvl= 50 lb Fl Fl* hl+h 2 57.3 lb 1,719·# 496.7 lb 37,749-# ~17.0 lb 110,040-# _____________________ ,_J sum: P=12000 lb 8,040 lb 150 lb W=8190 lb 420,420 1,471 lb I=149,SOB Lon ltudlnal Downalsle Seismic Load Slmllarly for longltudlnal seismic loads, using R=6.0 Cs1_=_S_d_1LIT"'.~).:: ~076_7 __ CS2= 0,0316 Cs3 = 0.0295 Cs-max= 0.0767 Level 1 2 3 PRODUC LOAD P 4,000 lb 4,000 lb 4,000 lb Ws= (0.67 * P~2 * P) + DL _ __ =_ 8,190 lb . __ .. • (1,c!ngltudln~. l)n_bra_c!!(I !21r,).~~ 6,0 __ ,..es_=Cs_-m_a_x_*I_p_=_0_.0_7_6_7 _____________ ~T~ 1.00 sec Vlong= 0.0767 * (150 lb + 8040 lb) Elongltudlnal= 628 lb Limit Sbtm Leroi l.otrglt. -le,,_, per upright P*0.67*PRF2 DL hi wi*hl 2,680 lb SO lb 61n 16,380 2,680 lb SO lb 521n 141,960 2,680 lb SO lb 961n 262,080 Fi Eri:mt Ille~ 24.5 lb 212.1 lb 391.5 lb sum: =======8=04=0=1=b===1=50=1=b==:W===B1=9=0=lb====4=2=0=4=20=======62=8=1b========= type c 5elect-qu1del.xl5 Page rof I y 12/8/2021 Structural Engineering & Design Inc. 1815 Wright Aye La Veme CA 91750 TeJ: 909,5961351 fax· 909 596 7186 By: Bob S Project: Quldel Downalsle Seismic Loads Configuration: Type C Selective Rack -96" Bay Determine the story moments by applying portal analysis. The base plate Is assumed to provide no fixity. Seismic Story Forces Vlong= 628 lb Vcol =Vlong/2= 314 lb Fl = 25 lb F2= 212 lb F3= 392 lb Seismic Story Moments I I ... 8 E3 S: E3-8: E3 I I -sss:es:s r-96' --1 ~ Qonoeotual System Project #: 21-1206-2 Typlc<II Fr.ime ~4c , _/_':~columns ~ Mbase-max= o In-lb Mbase-v= (Vcol*hleff)/2 <=== Default capacity hl-eff= hl • beam clip helght/2 = 3 In = 471 In-lb <=== Moment going to base Mbase-eff= Minimum of Mbase-max and Mbase-v = 0 In-lb PINNED BASE ASSUMED M 1-1= (Veal * hleff]-Mbase-eff M 2-2= [Vcol-(Fl)/2) * h2 = (314 lb * 3 ln)-0 In-lb = [314 lb · 106.1 lb]*46 ln/2 = 942 In-lb = 6,940 In-lb Msels= (Mupper+Mlower)/2 Msels(l·l)= (942 In-lb+ 6940 ln-lb)/2 = 3,941 In-lb Msels(2-2)= (6940 In-lb + 4305 ln-lb)/2 = 5,623 In-lb LEVEL 1 2 3 hi 6 In 461n 441n Axial Load 6,075 lb 4,050 lb 2,025 lb Summary of Forces Column Moment** Mselsmlc"'* 942 In-lb 3,941 In-lb 6,940 In-lb 5,623 In-lb 4,305 In-lb 2,153 In-lb Mconn= (Mselsmlc + Mend-flxlty)*0.70*rho Mconn-allow(3 Pin)= 12,691 ln-lb **all moments based on limit states level loading type c eelect-qutdel.xle Page lp of I '/ Mend-fixl 3,720 In-lb 3,720 In-lb 3,720 In-lb Vcol 7~tfl::=====ll.b h2 h1 Beam to Column Elevation rho= 1.0000 .Mconn** 5,363 In-lb 6,540 In-lb 4,111 In-lb _Beal)l Cortn~pr 3 pin OK 3 pin OK 3 pin OK 12/812021 COL Structural Engineering & Design Inc. 1815 Wrjaht Aye La Verne. CA 91750 Tel: 909,596,1351 Fax: 909 596.7186 By: Bob S Project: Quldel Project#: 21-1206-2 Column (Lonaltudlnal Loads) Configuration: Type C Selective Rack -96" Bay Section Properties Section: Hannibal IF3014-3x3x14ga Aeff = 0.643 ln"2 Ix :::: 1.130 ln"4 Sx = 0.753 ln"3 rx = 1.326 In nf= 1.67 E= 29,500 ksl Loads Considers loads at level 1 Iy = 0.749 ln"4 Sy = 0.493 ln"3 ry = 1.080 In Fy= 55 ksl Cmx= 0.85 COLUMN DL= 75 lb Critlca//oad cases are: RMI Sec 2.1 Kx = 1.7 Lx = 3.9 In Ky= 1.0 Ly= 36.0 In Cb= 1.0 y-·-·i-·-·-y io.075 In ~ lt ~.7Sln 3.000ln _j_ COLUMN PL= 6,000 lb Load case 5: : (1 +0.105*Sds}D + 0.75*(1.4+0.14Sds)*B*P + 0.75*(0.7*rho*E)<= 1.0, ASD Method Mcol= 942 In-lb axial load coeff: 0.78779505 * P seismic moment coeff: 0.5625 * Meo! Sds= 0.7183 Load case 6:: (1+0.14*Sds)D + (0.8S+0.14Sds)*B*P + (0.7*rho*E}<= 1.0, ASD Method 1 +0.105*Sds"' 1.0754 ax/a/ load coeff: 0.66539 seismic moment coeff: 0.7 * Meo/ By analysis, Load c.ase 5 governs utillzing loads as such 1.4+0.14Sds= 1.5006 l+0.14Sds= 1.1006 0.85+0.14*Sds= 0.9506 B= 0·.7000 rho= 1.0000 Axial Analysls Axial Load=Pax= 1,07s4215•7s 1b + o.75 • 1.soosez • o.7 • eooo 1b Moment=Mx= o.75*0,7*rho*Mcol = 4,807 lb = 0.525*942 In-lb = 495 In-lb Kxlx/hc = 1.7*3.9375"/1.326" = 5.0 Fe= n"2E/(KL/~)max"2 = 262.0ksi Pn= Aeff*Fn _ _ _ _ ___ "'. 3J_d;OJ }~ __ P/Pa= 0.28 Bending Analysis > 0.15 KyLy/ry = 1 *3611/1.0811 = 33.3 Fy/2= 27.5 ksl Qc= 1.92 Check: Pax/Pa+ (Cmx*Mx)/(Max*µx) :S 1.0 P/Pao + Mx/Max :S 1.0 Pno= Ae*Fy = 0.643 ln"2 *55000 psi = 35,365 lb Pao= Pno/nc = 353651b/1.92 = 18,419 lb Fe > Fy/2 Fn= Fy(1-Fy/4Fe) = 55 ksl*[l-55 ksl/(4*262 ksl)] = 52.1 ksl Pa= Pn/Qc = 33509 lb/1.92 . __ =_17,453 lb __ _ Myleld=My= Sx*Fy = 0.753 ln"3 * 55000 psi = 41,415 In-lb Max= My/.Qf Per= n"2EI/(KL)maxA2 = 41415 ln-lb/1.67 = 24,799 In-lb µx= {l/(1-(Qc*P/Pcr)]}"-1 = {l/[1-(1.92*4807 lb/168312 lb)]}"-1 = 0.95 Combined Stresses = n"2*29500000 psl/(1*36 ln)"2 = 168,312 lb (4807 lb/17453 lb) + (0.85*495 ln-lb)/(24799 ln-lb*0.95) = (4807 lb/18419 lb)+ (495 ln·lb/24799 In-lb) = 0.29 0.28 < 1.0, OK < 1.0, OK (EQ C5-1) (EQ CS-2) ** For comparison, total column stress computed for load case 6 Is: 26.0% i1q loads 4074.90255 lb Ax/a/ and M= 659 In-lb l;ype c select-qu1de!.xl~ f'a'Je ? of I 1/ 12/8/2021 Structural Engineering & Design Inc. 1s15 Weight Ave La Verne, CA e1z50 Jel· 909,596 1351 fax: 909,596.7186 By: Bob S Project: Quidel BEAM contlguration: Type c Selective Rack -%" Bay DETERMINE ALLOWABLE MOMENT CAPACITY Al Check compression flange for local buckling rn2,n w= e -2*t -2*r = 1.75 In -2*0.057 In -2*0.057 In = 1.522 In w/t= 26.7 - !=lambda= (1.052/(k)l'0.5] * (w/t) * (Fy/E)A0.5 = [1.052/(4)A0,5) * 26,7 * (55/29500)A0,5 = 0.606 < 0.673, Flange Is fully effective Bl check web for local buckling per section b2.3 fl(comp)= Fy*(y3/y2)= 50.53 ksl f2(tenslon)= Fy*(yl/y2)= 102.29 ksl Y= f2/fl = -2.024 k= 4 + 2*(1-Y)A3 + 2*(1-Y) = 65.35 flat depth=W= yl +y3 Eq . B2.3-5 Eq. B2.3-4 Eq. B2.1-4 Eq. B2.1-1 = 3.897 In w/t= 68.36842105 OK !=lambda= [1.052/(k)A0.5] * (w/t) * (fl/E)A0.5 = [1.052/(65.35)A0.5] * 3.897 * (50.53/29500)A0.5 = 0.368 < 0.673 be=w= 3.897 In bl= be(3-Y) = 0.776 b2= be/2 = 1.95 in bl+b2= 2.726 In > 1.2885 In, Web Is fully effectlve Determine effect of cold working on steel vleld point CEYa} per section A7.2 Fya= C*Fye + (1-C)*Fy (EQ A7.2-1) Lcorner=Le= (p/2) *_ (r + t/2) 0.134 In -Ltlange-top=Lf=-1.522 In - m= 0.192*(Fu/Fy) -0.068 = 0.1590 C= 2*Le/(Lf+2*Lc) == o:150-1n ---- (EQ A7.2-4) Be= 3.69*(Fu/Fy) -0.819*(Fu/Fy)A2 -1.79 = 1.427 since fu/Fv= 1.18 < 1.2 and r/t= 1 < 7 OK then Fye= Be * Fy/(R/t)Am (EQ A7.2-2) = 78.485 ksl Thus, Fya-top= 58.52 ksl (tension stress attop) Fya-bottom= Fya*Ycg/(depth -Ycg) = 113.59 ksl (tension stress at bottom) Check allowable tension stress for bottom flange Ltlange-bot=Lfb= Lbottom -2*r*-2*t = 2.522 In Cbottom=Cb= 2*Le/(Lfb+2*Lc) = 0.096 Fy-bottom=Fyb= Cb*Fye + (1-Cb)*Fyf = 57.26 ksl Fya= (Fya-top)*(Fyb/Fya-bottom) = 29.50 ksl Eq B2.3-2 (EQ A7.2-3) If F= 0.95 Then F*Mn=F*Fya*Sx=j 20.73 ln-k Project#: 21-1206-2 2,75 In ~51n 4 T 4.125In 1,625 In J_ 1 ~ 0,0571n Beam= HMH 41160/4 125" Face x 0 057" thk I I Ix= 1.617 lnA4 Sx= Q,740 jnA3 Ycg= 2.723 In t= 0.057 in Bend Radlus=r= 0.057 In Fy=Fyv= 55.00 ksi Fu=FUV= 65.00 ks! E= 29500 ksl top tlange=b=· 1.750 in bottom flange= 2,750 In Web depth= 4 1 '11; In ....:.; Fy - yl= Ycg-t-r= 2.609 In y2= depth-Veg= 1.403 In y3= y2-t-r= 1.289 In Structural Engineering & Design Inc. =============1!:!:s!:.!1::!:!s=w::!:!:!:rig~b='t=A='v~e:::::!!!La!!::::!!:y:!!!e!:!:rn!:!le!:!::, ~C;sA!:::!9~1=!:z::!:!s::!:!o=r::!:!e:!:!·::!:!e::!:!o~e!:!:!s::!:!a6~1:!:!!:35!!!::1:!:::!:::Fa~x2!:·::!!e!:!!!o~a!::!!s!:!!!a::!:!s~z::!:1::!:!s6!!!::=========== By: Bob S BEAM RMI Section 5.2, PT II SectJon Project: Quidel Contlguratlon: Type c Selective Rack -Yo" Bay Beam= HMH 41160/4.125" Face x 0.057" lhk Ix=Ib= 1.617 1nA4 Sx= 0.740 lnA3 t= 0.057 In Fy=Fyv= 55 ksl Fu=Fuv= 65 ksl Fya<= 58.5 ksl E= 29500 ksl F= 300.0 L= 96in Beam Level= 1 P=Product Load= 4,000 lb/pair D=Dead Load= 50 lb/pair 1, Check Bending Stress Allowable Loads Mcenter=P'Mn= W*L*W*Rm/8 Project#: 21-1206-2 2.751n tSln + T 4.125 In 1,625 In _J_ 1~ 0,057 In W=LRFD Load Factor= 1.2*0 + 1.4*P+1.4*(0.125)*P FOR DL=20/o of PL, RHI 2.2, Item 8 W= 1.599 Rm= 1 -((2-*F*L)/(6*E*Ib + 3*F*L)] 1 -(2*300*96 ln)/[(6*29500 ksl*l.617 1nA3)+(3*300*96 In)] = 0.845 If F= 0.95 Then F*Mn=F*Fya*Sx= 41.14 ln·k Thus, allowable load per beam palr=W= F*Mn*8*(# of beams)/(L*Rm*W) = 41.14 ln-k * B * 2/(961n * 0.845 * 1.599) = 5,075 lb/pair allowable load based on bending stress Mend= W*L *(1 ·Rm)/8 --= (507~ lb/2) * 96·1n *·(1~0.845)/8 = 4,720 In-lb @ 5075 lb max allowable load = 3,720 In-lb @ 4000 lb ln,posed product load 2. Check Deflection Stress Allowable Loads Dmax= Dss*Rd Rd = 1 -{4*F*L)/(S*F*L + lO*E*Ib) = 1 -(4*300*96 ln)/[(5*300*96 ln)+(10*29500 ksl*l.617 1nA4)] = 0.814 In If Dmax= L/180 Based on l/180 Dellectfon Criteria and Dss= 5*W*LA3/(384*E*Ib) L/180= 5*W*lA3*Rd/(384*E*Ib*# of beams) solving for W yields, W= 384*E*I*2/(180*5*L A2*Rd) = 384*1.617 1nA4*2/[180*5*(96 ln)A2*0.814) = 5,426 lb/pair allowable load based on deflection limits Thus, based on the least capacity of Item 1 and 2 above: 1-I lllllllll!IIOIIOIIIOIIIIIOIIO!IOIIOIII }-=~~~~~~ .. - '~----____________ ...... . ' I • • • • • · Pra4v•II: ...... . . . . . . !Beam· llwel!llgil:nl - Ill 1:1 Allowable Deflection= L/180 = 0.533 In Deflection at Imposed Load= 0.420 In Alowab Imposed Product Load= 4,000 lb/pair Beam Stress= .7 Beam at Level 1 Structural Engineering & Design Inc. 1616 Weight Ave I a Yecoe CA 91760 Iel· RCS 596 1361 Eu sos 686 ?186 By: Bob S Project: Quidel Project#: 21-1206-2 3 Pin Beam to Column Connection Type C Selective Rack -96" Bay I he beam end moments shown herein show the result of me maximum Induced Hxed end monents form seismic + static loads and the code mandated minimum value ot· 1.5%(DL+PL) Mconn max= (Mselsmlc + Mend-flxlty)*0,70*Rho = 5,363 In-lb Load at level 1 Connector Type= 3 Pin Shear Capacity or Pin Pin Diam= 0.44 In Ashear= (0.438 ln)"2 * Pl/4 = 0.1507 ln"2 Pshear= 0.4 * Fy * Ashear = 0.4 * 55000 psi * 0.1507In"2 = 3,315 lb Bearing Capacity of Pin tcol= 0.075 In Omega= 2.22 Fy= ss,ooo psi Fu= 65,000 P-SI a= 2.22 Pbearlng= alpha "' Fu "' diam "' tcol/Omega = 2.22 "' 65000 psi * 0.438 In * 0.075 ln/2.22 = 2,135 lb < 3315 lb Moment capacity or Bracket Edge Dlstance=E= 1.00 In Pin Spacing= 2.0 In C= P1+P2+P3 tcllp= 0.18 In = Pl +Pl *(2.5"/4.5")+P1 *(0.5"/4.5") = 1.667 * Pl Mcap= Scllp * Fbendlng = 0.127 ln"3 * 0.66 * Fy = 4,610 In-lb Pcllp= Mcap/(1.667 * d) C*d= Mcap = 1.667 == 4610.1 in-lb/(1.667 * 0.5 In) = 5,531 lb Thus, Pl= 2,135 lb Mconn-allow= [Pl *4.S"+Pl *(2.5"/4.5")*2.S"+Pl *(0.5"/4.5")*0.5"] = 2135 LB*[4.5"+(2.5"/4.5")*2.5"+ (0.5"/4.5")*0.5"] = 12,691 In-lb > Mconn max, OK type c :,elect-qu1del.xls Page 1 of(</ ---,.- 1' I 2' Fy= 55,000 psi Scllp= 0.127 ln"3 d= E/2 = 0.50 In rho= 12/8/2021 Structural Engineering & Design Inc. 1815 Weight Aye La Verne CA 91750 Tel; 909,5961351 fax; 909 596 7186 By: Bob S Project: Quidel Project#: 21-1206-2 Transverse Brace Configuration: Type C Selective Rack -96" Bay Section Properties Diagonal Member= Hannibal 1-1/2x1·1/2x16ga Area= 0.273 ln"2 k,_1.soo In _,.j r min= 0.496 In I I Fy= 55,000 psi nf K= 1.0 1.~00 In nc= 1.92 ....L -I 1--o:2so In Frame Dimensions Diagonal Member Bottom Panel Helght=H= 48.0 In Frame Depth=D= 42.0 In Column Wldth=B= 3.0 In -.o Horizontal Member= Hannibal 1-1/2xl -1/2x16ga Area= 0.273 ln"2 r min= 0.496 In Fy= 55,000 psi K= 1.0 Clear Depth=D-B*2= 36.0 in X Brace= NO rho= 1.00 I Load case 6:: (LJ:J} '(14//(_Gfs)D + f(0.85+0.14Sds}*B*P + [0.7*rho*EJ<= 1.0, ASD Method Vtransverse= 1,471 lb Vb=Vtran1V*0,7*rho= 1471 lb * 0.7 * 1 = 1,030 lb Ldlag= [(D-8*2)"2 + (H-6")"2]"1/2 = 55.3 In Pmax= V*(Ldlag/D) * 0.75 = 1,017 lb axial load on dla onal brace member Pn= AREA*Fn = 0.273 ln"2 * 23419 psi = 6,393 lb Pallow= Pn/n = 6393 lb /1.92 = 3,330 lb (kl/r)= (k * Ldlag)/r min = (1 x 55.3 In /0.496 In ) = 111.5 In Fe= pl"2*E/(kl/r)A2 = 23,419 psi Since Fe<Fy/2, Fn= Fe = 23,419 psi Check End Weld Lweld= 3.0 In Fu= 65 ksf tmln= 0.060 In :rvo1ca1 eaoel Contl!lucatloo Pn/Pallow= Horizontal brace 0.31 <= 1.0 OK Weld Capacity= 0.75 * tmln * L * Fu/2.5 Vb=Vtran1V•0.7*rho"' 1,030 lb (kl/r)= (k * Lhorlz)/r min = (1 x 42 In) /0.496 In = 84.7 In Since Fe>Fy/2, Fn=Fy*(1-fy/4fe) = 36,366 psi Pn/Pallow= 0.20 type c ~elect-qu1del.xls <= :i.O OK Fe.:: pl" 2*E/(kl/r)" 2 = 40,584 psi Pn= AREA*Fn = 0.2731n"2*36366 psi = 9,928 lb f'a,ae / '-' of / f = 3 510 lb OK Fy/2= 27,500 psi Pallow"' Pn/nc = 9928 lb /1.92 = 5,171 lb 12/8/2021 Structural Engineering & Design Inc. 1a15 Weight Ave La Verne, QA 91750Tet· 909,596.1351 fax· 909 596,7186 By: BobS Project: Quidel Project#: 21-1206-2 Single Row Frame Overturning Configuration: Type C Selective Rack -96" Bay Loads Crltlcal Load case(s): 1) RMI Sec 2.2, Item 7: (0.9-0.2Sds)D + (0.9·0.20Sds)*B*Papp -E*rho Scls= 0.7183 (0.9·0.2Sds)= 0.7563 (0.9-0.2Sds)= 0.7563 Vtrans=V=E=Qe= 1,471 lb DEAD LOAD PER UPRIGHT=D= 150 lb PRODUCT LOAD PER UPRIGHT=P= 12,000 lb Papp=P*0.67= 8,040 lb Wst. LCl==Wst.1=(0.75634*D + 0.75634*Papp*1)= 6,194 lb B=. --- Product Load Top Level, ptop= 4,000 lb DL/Lvl= 50 lb Seismic Ovt based on E, .E(Fl*hl)= 101,070 in-lb hetoht/deoth ratio= 2.3 In Al Fullv Loaded Rack Load case 1: Movt= .E(R*hl)*E*rho = 101t070 In-lb rho= 1.0000 Frame Depth=Df= 42.0 In Htop-lvl=H= 96.0 In # Levels= 3 # Anchors/Base= 1 ho= 48.0 In h=H+ho/2= 120.0 In Mst= Wstl * Df/2 = 6194 lb * 42 in/2 = 130,074 In-lb STDE ELEVATION T= (Movt-Mst)/Df = (101070 In-lb -130074 ln-lb)/42 In = -691 lb No Uplift I Net Seismic Upllft= •691 lb B} TOD Level Loaded Onlv Load case 1: 0 Vl=Vtopc Cs * Ip* Ptop >= 350 lb for H/D >6.0 Movt= [Vl *h + V2 * H/2]*rho = 0.1796 * 4000 lb = 87,501 In-lb = 718 lb T= (Movt-Mst)/Df Vleff= 718 lb Critical Level= 3 = (87501 In-lb • 65915 ln-lb)/42 In --· -. 'j2=_v_QL_ = ~*~R*.Q --· --..... _ ... _________ <:;s~IP..'7' _Q.l-796 __ -·----·-.. -. ___ =;: 514 lb _ _ Net.Uplift: per.Column = 271b Mst= (0.75634*1? + 0.75634*ptop*1) * 42 ln/2 = 65 915 In-lb I Net Seismic UDllft= 514 lb Anchor Check (1) 0,5" x 2" Embed HILTI KWIKBOLT TZ anchor(s) per base plate. Special Inspection Is required per ESR 1917. Fully Loaded: Top Level Loaded: L.A. aty Jurisdiction? NO Pullout Gapacity=Ttap= 970 lb Shear Gapacity=Vcap= 1,250 lb Phi= 1 (735 lb/1250 lb)Al = (514 lb/970 lb)Al + (359 lb/1250 lb)"l = type c select-qu1del.xls Page / / of I Y 0.59 0.82 Tcap*Phl== 970 lb Vcap*Phl= 1,250 lb <= 1.2 OK <= 1.2 OK 12/8/2021 Structural Engineering & Design Inc. 1815 Weight Ave La Verne, CA 91750 Je!; 909,596.1351 fax· 909 596,7186 By: Bob S Project: Quldel Project#: 21-1206-2 Base Plate Configuration: Type C Selective Rack -96" Bay Section Baseplate= 8x5x3/8 Eff Wldth=W = 8.00 In Eff Depth=D = 5.00 In Column Wldth=b = 3.00 In Column Depth=dc = 3'.00 In L = 2.50 In Plate Thlckness=t = 0.375 In a = 3.00 In Anchor c.c. =2*a=d = 6.00 In N=# Anchor/Base= 1 Fy = 36,000 psi +-a-+ P Mb b w Downa1s1e Elevation Down Aisle Loads Load case 5:: {1+0.105*Sds)D + 0.75*((1.4+0.14Sds)*B*P + 0.75*(0.7*rho*El<= 1.0, ASD Method COLUMN DL= 75 lb Axlal=P= 1,0754215 * 75 lb+ 0.75 * (1,500562 * 0.7 * 6000 lb) COLUMN PL= 6,000 lb = 41807 lb Base Moment= 0 In-lb Mb= Base Moment*0.75*0.7*rho 1+0.105*Sds= 1.0754 = 0 In-lb* 0.75*0,7*rho 1.4+0.14Sds= 1.5006 = 0 In-lb B= 0,7 , Axial Load P = 4,807 lb Mbase=Mb = 0 In-lb Axial stress=fa = P/A = P/(D*W) = 120 psi Moment Stress=fb = M/S = 6*Mb/[(D*B"2] = 0.0 psi Moment Stress=fbl = fb-fb2 = 0.0 psi M3 = (1/2)*fb2*L*(2/3)*L = (1/3)*fb2*L"2 = 0 ln:lb S-plate = (l)(t,,...2)/6 = 0.023 ln,,...3/ln fb/Fb = Mtotal/[(S-plate)(Fb)] 0,59 OK Tanchor = (Mb-(PLapp*0.75*0.46)(a))/[(d)*N/2] = -6,194 lb No Tension Ml= wl "2/2= fa*L "2/2 = 376 In-lb Moment Stress=fb2 = 2 * fb * L/W = 0.0 psi M2= lbl *L "2)/2 = 0 In-lb Mtotal = Ml+M2+M3 = 376 In-lb/In Fb = 0.75*Fy = 27,000 psi F'p= 0.7*F'c = 1,758 psi Tallow= 970 lb OK OK em Effe Cross Alsle Loads 01/ICA/lo«ICMORHrs«:2.1, 11en,f:(1+0.11Sds){)t. +(1+0.J451)5}Pl.•o.1s+EJ."O.JS <• 1.4 ASD~~ Check upllft load on Baseplate.----·---· . __ -·-- Pstatlc= 4,807 lb Movt*0.75*0.7*rho= 53,062 In-lb Frame Depth= 42.0 In P=Pstatlc+Pselsmlc= 6,071 lb b =Column Depth= 3.00 in L =Base Plate Depth-Col Depth= 2.50 In fa = P/A = P/(D*W) = 152 psi Sbase/in = (1)(t"2)/6 = 0.023 ln"3/ln fb/Fb = M/[(-S~plate)(Fb)] = 0.75 OK type c select-qu,del.xls Pselsmlc= Movt/Frame Depth = 1,263 lb M= wl"2/2= fa*L"2/2 c: 4 74 In-lb/In Fbase = 0.75*Fy = 27,000 psi Page / )_ of t 1/ Check uplift forces on baseplate with 2 or more anchors per RMI 7.2.2. When the base plate r.onrlguratlon consists or two anchor bolts located on either side f the column and a net uplift force exists, the minimum base plate thickness hall be determined based on a design bending moment In the plate equal the uplift force on one anchor times 1/2 the distance from e centerline or the anchor to the nearest edge or the rack column" ~ Uplift per Column= 514 lb Qty Anchor per BP= 1 Net Tension per anchor=Ta= 514 lb c= 2.50 In Mu=Moment on Baseplate due to uplift= Ta*c/2 fb Fb *0.75= 0.152 = 643 In-lb Splate= 0.117 ln"3 OK 1218/202 r Structural Engineering & Design Inc. 1815 Weight Ave La Verne, CA 91750 Jel· 909.596.1351 fax· 909.696.7186 By: BobS Project: Quldel Project#: 21-1206-2 Slab on Grade Configuration: Type C Selective Rack -96" Bay a I ~ ~ ~li'ffiffli'ii'l'li'i'i'i'ffi'ffl'i'l'l'm'f'i'l'llllmmm'ffii'n'n1Fii"i'ffffiffii'ir\"~ l [al e I I I I ~---·c ____ , re= 2,511 psi tslab=t= 4.8 In y L SLAB ELEVATION _J __ j ,SQ!! fsoll= 750 psf Movte:: 101,070 In-lb Frame depth= 42.0 In Baseplate Plan View Sds= 0.718 0.2*Sds= 0.144 Base Plate Effec, Baseplate wldth=Ba 8.00 In _ Effec, Baseplate DepthaD= 5.00 In wldth=a= 3.00 In depth=b= 3.00 In f3=B/D= 1.600 F"cAQ.5= 50.10 psl Column Loads DEAD LOAD=D= 75 lb per column unfactored ASD load PRODUCT LOAD=P= 6,000 lb per column unfactored ASD load Papp= 4,020 lb per column P-selsmlc=E= (Movt/Frame depth) = 2,406 lb per column Be: rho= unfactored Limit State load Sds= 0.7183 1.2 + 0.2*Sds= 1.3437 ___ 0. 9 • 0.20Sds=_ 0.7563 ___ _ Puncture Apunct= [(c+t)+(e+t)]*2*t = 180.50 lnA2 Fpunctl= [(4/3 + 8/(3*{3)] *.A *(F"c"0.5) = 90.2 psi Fpunct2= 2.66 * ).. "' (F"cAO.S) = 80. psi Fpunct eff= 80. psi - Slab Bending Pse=DL+PL+E= 8,496 lb Asoll= (Pse*144)/(fsoll) = 1,631 ln"2 x= (L-y)/2 = 13.1 In Fb= 5*(phl)*(fc)A0.5 = 150.33 psi type c select-qu1del.xl5 midway dist face of column to edge of plate=c= 5.50 In midway dist face of column to edge of plate=e= 4.00 In Load case 1) (1.2+0.2Sds)D + (1.2+0.2Sds)*B*P+ rho*E RMISEc 2.2 EQTN s = 1.34366 * 75 lb + 1.34366 * 0.7 * 6000 lb + 1 * 2406 lb = 8,150 lb Load Case 2) (0.9-0.2Sds)D + (0.9-0.2Sds)*B*Papp + rho*E RMI SEC 2,2 EQTN 7 = 0.75634 * 75 lb+ 0.75634 * 0.7 * 4020 lb+ 1 * 2406 lb = 4,591 lb Load Case 3) 1.2*D + 1.4*P = 1.2*75 lb + 1.4*6000 lb = 8,490 lb Load case 4) 1.2*D + 1.0*P + LOE = 8,496 lb Effective Column Load=Pu= 8,496 lb per column L= (Asoll)A0.5 = 40.39 In M= w*x"2/2 = (fsoll*xA2)/(144*2) = 446. 7 In-lb Page/ b of/ l-j fv/Fv= Pu/(Apunct*Fpunct) = 0.589 < 10K y= (c*e)A0,5 + 2*t = 14.2 In 5-slab= 1 *teff"2/6 = 3.76 ln"3 fb/Fb= M/(S-slab*Fb) = 0.790 < 1, OK RMI SEC 2.2 EQTN 1,2 AC! 318-14 Sec S.J,1 Eqtn 5.3.le 12/8/2021 Structural Engineering & Design Inc. 1815 Weight Ave La Verne, CA 91750 Tel: 909.596 1351 fax· 909,596 7186 By: Bob S Project: Quidel Project#: 21-1206-2 Configuration & Summary: Type C Selectlve Rack~ 48" Bay T- 44" 96" t 46" t 6" I ' ' T 48" %" t 36" 1_. **RACK COLUMN REAcrJONS ASOLOADS AXIAL DL= 75 lb AXIAL LL':' 3,000 lb SEISMIC AA1Al Ps=+/· 1,236 lb BASE MOMENT= 0 In-lb .-r -48" ----..r ,r-42" -,r Seismic Criteria Ss=0.96B, Fa=1.113 Component Column Column & Backer Beam Beam Connector Brace-Horizontal Brace-Diagonal .. Base Plate Anchor Slab& Soll Level I Load** Per Level 1 2 3 2,000 lb 2,000 lb 2,000 lb # Bm Lvls Frame Depth Frame Hel Beam Length Frame Type 3 42 in 96.0 In 48In Single Row Fy=55 ksl None Fy=55 ksl Fv=55 ksi Fy=55 ksl Fy==55 ksl Fy=36 ksi 1 oer Base Beam $oca 6.0 In 46.0 In 44.0 in Description Hannibal IF3014-3x3x14ga P=2050 lb, M=3536 In-lb None None HMH 24160/2.5" Face x 0.057" thk Lu=4B In I Capacity: 5146 lb/pr Lvl 1: 3 pin OK I Mconn=2342 In-lb I Mcap=12691 In-lb Hannlbal 1-1/2x1 -1/2xl6ga Hannibal 1-1/2x1-1/2x16ga 8x5x3/8 I Fixity= 0 In-lb 0.5" x 2" Embed HILT! KWIKBOLTTZ ESR 1917 Inspection Reqd (Net Seismic Upllft=244 lb) 4.75" thk x 2511 psi slab on grade. 750 psf Soll Bearing Pressure p~_ 36.0 in 48.0 in I Story Force I Story Force __ Jritnsx.. .. ..L.onglt ... 29 lb 253 lb 467 lb 13 lb 108 lb 200Ib Column .. Axial 3,075 lb 2,050 lb 1,025 lb I Column I Conn, _ __ Moment ___ Moment 480 "# 3,536 "# 2,193 "# 2,342 "# 2,942 "# 1,704 "# STRESS 0.14-OK N/A 0.39-OK 0.1B-OK 0.1-OK 0.16-OK 0.38-OK 0.325-OK 0.3-OK Beam Connector 3 pin OK 3 pin OK 3 pin OK *" Load defined as product weight per pair of beams Total: 749Ib 320 lb type c-48 M lect-qu1del.xle, f'aqe I '-/of I <-j 12/8/20 2 1 .._\\. KLAUSB FlUC.KN ER ) \ l AND ASSOCIATES 2495 Truxtun Road. Suite 205 San Diego, CA 92106 QUIDEL INC. (OUTDOOR SHED) 2285 Rutherford Road Carlsbad, CA High-Piled Combustible Storage Report Rev 1.1 January 11, 202 Tel: (619) 677-2004 Fax: (619) 677-2444 1. Summary Table TOPIC CODE SECTION Construction See Architectural Type (Section Plans 3.1 on Page 6) Approximate See Architectural Square Footage Plans (Section 3.2 on Page 6) Additional Applicable to: Required Plan Racking Plan, Annotations Sprinkler Plan, Architectural Plan Occupancy CBC Sections (Section 3.2 on 302,304, Page 6) 306, 311, Table 508.4 (see Attachments for more details) (see Attachments for more details) Approved CFC, Section Storage Layout 3201.3.2 Structural Rack CBC Calculations Automatic CFC Sections Sprinkler 3207.2, Rev 1./ -QUIDEL INC. 2285 Rutherford Road, Carlsbad, CA CRITERIA/REQUIREMENTS Outdoor Shed Attached to Existing Building Existing Building -No Proposed Changes to the Main Building. Fully Sprinklered Building, Ill-A Construction, 2-Stories Above Grade Outdoor Shed: 416 ft"'[S-1, High-Piled Storage] Warehouse Total: 13,060 tt2 [S-1, Storage] Manufacturing Area: Unknown ftl [F-1, Manufacturing] Storage Area incl Shed: 13,476 ft' [S-1, High-Piled Storage] Remainder: Unknown ftl & Outside the Scope Other Uses: Unknown tt2 & Outside the Scope NOTE: Main building previously approved and for background information only. Scope of the report is limited ot the sorage in outdoor shed only. "Approval of this plan in part is based on the technical High-Piled Combustible Storage Report prepared by Klausbruckner & Associates, dated January 11, 2022, Rev 1.1. QUIDEL INC. agrees to comply with the requirements set forth in the referenced report. A copy of the reference report shall be maintained and immediately available for Fire Department Inspection for the duration of the reQuested hi!lh pile storage" Outdoor Shed: Single Use Group: S-1 (Storage) Existing Building: Mixed Use Groups: B (Offices), F-1 (Manufacturing) and S-1 (Storage), unless otherwise specified by the Architect of Record. No occuoancv seoaration reQuired between B, F-1 and S-1. High Hazard: Outdoor Shed Storage: Empty 4-Gallon Rubbermaid Trash Cans, Fiber Board Cy Boxes, Empty Steel And Poly Drums, Chemical Spill Containing Absorbent Pads, Shovel, etc. Flammable Cabinets (in Outdoor Shed): Universal Waste Staging for Small Quantities of Light Bulbs, Batteries (Alkaline, NiMH, Lead Acid, etc. -Staged in 5-Gallon Polyethylene UN Rated Buckets), Non-PCB Ballasts (5-Gal Poly UN bucket), etc. Protection based on highest hazard commodity within Chapter 32. Hazardous materials outside the scooe of this report. A floor plan, of legible size, shall be provided, mounted on a wall and protected from damage. The floor plan shall be mounted in an approved location. It shall show the information listed in Section 7 of this report. Approved Storage Layout by others. Not within the scope of this report. Structural & (seismic) rack calculations are reauired for high-piled storage permit aooroval. Sprinkler System Upgrades Are Required. (Storage Area layout per Attachment #1 on page 21) Page I I Protection (Section 4.1 on Page 8) 3208.1, 3208. to 3208.4, Table 3206.2, NfPA-13 General Sections 3.9.1.13, 3.9.1.18, 3.9.3.7.4, 3.9.3.7.7, 3.9.3.8, 3.9.3.9, 8.5.5.3.1, 8.5.6.1, 8.6.2.2.1, Table 8.6.2.2.1 (b), 8.6.3.4.1, 12.1.2, 12.6.1, 12.6.2, 12.8.6, Table 12.8.6 NfPA 13 (2016 Edition) Specific Sections Rack Storage 13.2.1 Tables 13.2.1 Figures 13.2.1 Rev I. I -QUIDEL INC. 2285 Rutherford Road, Carlsbad, CA Rack Storage Area Within Outdoor Storage Shed Sprinkler Protection*: CLASS I-IV, CARTONED EXPANDED & UNEXPANDED AND EXPOSED UNEXPANDED & EXPANDED GROUP A PLASTICS COMMODITIES * Meeting definition of Miscellaneous Storage ■ Maximum Storage Height: :;; 8'-0" ■ Maximum Ceiling Height < 11'-0" • Aisle Widths: .:: 3'-8" (44") ■ Single Row Racks ■ Open Shelving > 50% open Ceiling Sprinkler Design Required.· • Control Mode Density Area (CMDA), minimum K-factor: (Installed K-factor: 5.6), listed for storage ordinary (165°f) or high (286°f) temperature, pendent sprinklers ■ Minimum density of 0.20 gpm/ft2 over 1,500 ft 2 remote area ■ In-Rack Sprinklers: One line of in-rack sprinklers located at first tier level • Maximum coverage area 130 ft2 ■ Maximum spacing between sprinklers 15'-0" ■ Minimum spacing between sprinklers 6'-0" ■ Minimum 18" clearance from deflector to top of storage ■ Hose allowance of 500 gpm ■ Water supply duration of 90 minutes Proposed CMDA ceiling sprinkler system designed to 0.20 gpm/ft2 over 1,500 ft2 remote area with one level of in-racks will meet the requirement for protection above. Additional upgrades and/or calculations are required. Non High-Piled Floor Storage Within Outdoor Storage Shed Sprinkler Protection: CLASS I-IV, CARTONED AND EXPOSED, EXPANDED AND UNEXPANDED GROUP A PLASTICS COMMODITIES • Maximum Storage Height: :::: 5' (Plastics) ■ Maximum Ceiling Height: < 11'·0" Ceiling Sprinkler Design Required: • Control Mode Density Area (CMDA), minimum K-Factor: K- 5.6, not required to be listed for storage, ordinary (165°f) or high (286°f) temperature, upright or pendent sprinklers ■ Minimum density of 0.20 gpm/ft2 over 1,500 ft2 remote area ■ Maximum coverage area 130 ft2 • Maximum spacing between sprinklers 15'-0" ■ Minimum spacing between sprinklers 6'-0" ■ Minimum 18" clearance from deflector to top of storage ■ Hose allowance of 250 gpm ■ Water supply duration of 90 minutes Proposed CMDA ceiling sprinkler system designed to 0.20 gpm/ft2 over 1,500 ft2 remote area will meet the requirement for protection above. Additional upgrades and/or calculations are required. See Section 4.1 of this report for additional requirements Page 12 Adjacent Hazards, Extent of Protection (Section 4.1.3.1 on Page 7) Smoke and Heat Removal Flue Spaces (Section 4.9 on Page 14) {if: Solid Shelves (Section 4.1.3.6 on Paae 10)} Building Access Road & Doors (Section 4.3 on Page 11) Aisle Width (Section 4. 7 on Page 13) Fire Extinguishers (Section 4.6 on Page 13) (see Attachments for more details) CFC 3206.2 and NFPA 13, Section 12.3.(1) (see Attachments for more details) CFC Table 3206.2 CFC Section 3208.3, Table 3208.3 (see Attachments for more details} NFPA 13 Section 17.1.5 CFC Table 3206.2, Sections 503.1.1, 503.2-8, 3206.6, 3206.7 (see Attachments for more details) CFC 3206.10 CFC 3206.10.3 (see Attachments for more details) CFC Section 3206.11, 906 and Tables 906.1, 906.3 (1) & (2), 906.9 Rev I. I -QUIDEL INC. 2285 Rutherford Road, Carlsbad, CA Other Areas, Including Main Building Not Within the Scope High Piled Storage Area will extend over the single row rack of the outdoor shed. Extent and type of protections {including automatic sprinkler design densities) shall extend to a permanent partition. In-rack protection shall extend only over the racks. Smoke and heat removal is not required for storage of High Hazard/Group A Plastics less than 2,500 square feet NOTE: Smoke and Heat Vents previously addressed for high piled storage areas in the Main Building (under separate permits). Single Row Racks": Transverse -3-inches required .,.... Longitudinal -Not required -Transverse Flue Spaces: Random variations (in flue space size) are allowed, provided the distribution of water is not obstructed See Section 4. 9 of this report for additional details on flue spaces and reQuired flue soace protection devices No solid shelves (greater than 20 square feet between approved flue spaces} are permitted in the racks. Access Roads: • Access roads required by CFC Section 503 • Access roads are existing and have been approved as part of the shell building plans. Access Doors: • Access Doors are not required in sprinklered high-piled storage areas of Group A Plastics/High Hazard Commodities less than 2,500 ft2. See Section 4.3 of this report for additional details on access doors. NOTE: Access roads and doors previously addressed for high piled storage areas in the Main Building (under separate permits). • Aisles of at least 44" are required in sprinklered buildings with high-piled storage exceeding 500 square feet Cross aisles used only for employee access between aisles shall be a minimum of 24" wide • Quidel Inc. agrees to maintain a minimum of 44" aisle widths within the rack storage area in order to comply with the sprinkler requirements stated in Section 4.1 of this report. • Dead-end aisles shall not exceed 50 ft in length NOTE: Any floor/palletized storage cannot obstruct the minimum width of the aisles. See Section 4.7 of this report for additional details on aisle widths. High-piled Storage Areas: 4-A:20-B:C ; • Maximum travel distance 75 ft*; • Maximum area per extinguisher 4,000 ft2 * If no flammable liquids are stored, otherwise travel distance Page I 3 (see Attachments for more details) Hazardous N/A Materials Allowable Area CBC Table 503 (see Attachments for more details) Rev 1.1 -QU!DEL INC. 2285 Rutherford Road, Carlsbad, CA :'.5: 50 Feet See Section 4.6 of this report for additional details on fire extinguishers. NIA Not part of the scope of this report Not within the scope of this report. Existing building. No proposed changes to type of construction, building square footage or occupancy unless otherwise specified by the Architect of Record. Page 14 Hazardous Materials Questionnaire County of San Diego, Department of Environmental Health and Quality PO Box 129261, San Diego, CA 92112-9261 (858) 505-6700 (800) 253-9933 www.sdcdeh.org Record ID #: Not in System Plan Check#: DEH2021-HHMBP- 010061 Business Name Business Contact Telephone# Plan File# Quidel Corporation Tim Free 9498611881 Project Address City Zip Code APN# 2285 Rutherford Rd Carlsbad I State CA 92008 2120620800 Applicant Applicant E-Mail Applicant Telephone# Tim Free tim@548group.com 9498611881 The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT -HAZARDOUS METERIALS DIVISION: OCCUPANCY CLASSIFICATION:(Not required for projects within the City of San Diego.) Indicate by selecting the item. whether your business will use. process, or store any of the following hazardous materials. If any of the items are selected, Applicant must contact the Fire Protection Agency with Jurisdiction prior to plan submittal. Occupancy Rating: Facility's Square Footage (including proposed project): □ Explosive or Blasting Agents □ Organic Peroxides □ Water Reactives □ Corrosives □ Compressed Gases □ Oxidizers □ Cryogenics □ Other Health Hazards □ Flammable/Combustible Liquids □ Pyrophorics □ Highly Toxic or Toxic Materials □ None of These □ Flammable Solids □ Unstable Reactives □ Radioactives PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION (HMDl:tf the answer 10 any of the questions is yes. applicant must contact the County of San Diego Hazardous Materials Division, in person at 5500 Overland Ave., Suite 110, San Diego. CA 92123, or by phone at(858) 505-6700 prior to issuance of a building permit. FEES ARE REQUIRED. Project Completion Date: 71212021 1. 2. 3. 4. 5. 6. 7. 8. YES NO li!I □ Is your business listed on the reverse side of this form? (check all that apply). □ li!I Will your business dispose of Hazardous Substances or Medical Was1e in any amount? li!I ll!l □ □ □ □ 0 Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds, or 200 cubic feet? □ li!I li!I li!I Will your business handle carcinogens or reproductive toxins in any quantity? Will your business use an existing. or install an underground storage tank? Will your business store or handle Regulated Substances (CalARPI? Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? li!I Will your business store petroleum in tanks or con1ainers at your facility with a total storage capacity equal to or greater than 1.320 gallons? (California's Aboveground Petroleum Storage Act). □ □ □ CalARP Exempt CalARP Required CalARP Complete Review Date: PART Ill; SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCDl: If the answer to Question #1 is 'Yes' and the answer to Question #2 is 'No', the applicant must contact the APCD prior to the issuance of a building or demolition permit. If any answer to Questions #3, #4, or #5 is 'Yes', the applicant must contact the APCD prior to the issuance of a building or demoli1ion permit. If the answer to Question #3 or #4 is 'Yes', the applicant may need to submit an asbestos notification form to the APCD at least 10 working days prior to commencing demolition or renovation (some residential projects may be exempt from the notification requirements). Contact the APCD at 10124 Old Grove Road, San Diego, CA 92131 or telephone (858) 586-2600 for more information. 1. 2. 3. 4. YES NO □ □ □ □ □ □ □ 0 Will any existing building materials be disturbed as part of this project? (If the answer is 'Yes', an asbestos survey may be required.) Has a survey been performed to determine the presence of asbestos containing materials? Will the project involve handling or disturbance of any asbestos containing materials? Will the project involve the removal of any load supporting structural member? 5. □ □ □ □ Will the subject facility or construction activities include operations or equipment that emit or are capable of em,tting an air contaminant? (See the APCD factsheet at http://www.sdapcd.org/info/facls/permits.pdf 6. (ANSWER ONLY IF QUESTION 5 IS 'YES') Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? Search the California School Directory al http://www.cde.ca.gov/re/sdlfor public and private schools or contact the appropriate school district. Briefly d ascribe business activities: Biotechnology -In Vitro diagnostics kit manufacturer (e.g. SARAS Antigen, lnfl uenza, etc.) Briefly describe proposed project: Installation of warehouse racking and safety barriers I declare under penalty of perjury that to the best of my knowledge and belief, the responses made herein are true and correct. ll!l: Fees Acknowledged: 00 TIMOTHY FREE 5112/2021 Name of Owner or Authorized Agent Date FOR OFFICIAL USE ONLY FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: BY: DATE: ___________ _ EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMO* APCD COUNTY-HMO APCD COUNTY-HMO APCD *A stamp in this box !rn!y_ exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply. OEHQ_ HMO _HM BP_ Questionnaire v 1.34 (212021) Printed on: 5/24/2021@ 1:11 PM Note: As per the customer, the facility does not have any hazmat at this time. □ □ □ □ □ □ □ □ □ □ ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com Date: 12.16.2021 Business Name; Quidel --------------------- Street Address: 2285 Rutherford Road, Carlsbad, CA 92008 Email Address: Logan@548group.com PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT 10N REVERSE SIDE CHECK TYPE OF BUSINESS! □ Check all below that are present at your facility Acid Cleaning 0 Food Processing 0 Metal Powders Forming Assembly 0 Glass Manufacturing D Nutritional SupplementNitarrnn Automotive Repair 0 Industrial Laundry 0 Manufacturing Battery Manufacturing O Ink Manufacturing O Painting/Finishing Biofuel Manufacturing D Laboratory O Paint Manufacturing 81otech Laboratory 0 Machining/Milling 0 Personal Care Products Bulk Chemical Storage 0 Membrane manufacturing 0 Manufacturing Car Wash O (ie. waterfilter membranes) O Pesticide Manufacturing/ Packaging Chemical Manufacturing O Metal Casting/Forming O Pharmaceutical Manufacturing Chemical Purification 0 Metal Fabrication 0 (including precursors) 0 Dental Offices D Metal Finishing 0 Porcelain Enameling D Dental Schools 0 Electroplating 0 Power Generation O Dental Clinics 0 Electroless Plating 0 Print Shop 0 Dry Cleaning 0 Anodizing 0 Research and Development □ Electrical Component 0 Coating (i.e. phosphating) 0 Rubber Manufacturing □ Manufacturing 0 Chemical Etching/Milling 0 Semiconductor Manufacturing □ Fertilizer Manufacturing 0 Printed Circuit Board 0 Soap/Detergent Manufacturing □ Film/ X-ray Processing D Manufacturing O Waste Treatment/Stora!'.je New Business? YesEJNoO SIC Code(s) if known Date operation began/will begin 09.01.2021 est Tenant Improvement? YesG NcQ If yes. briefly describe 1m provement Installation of prefabricated high pile 1 acking outside warehouse. Description of operations generating wastewater (discharged to sewer, hauled orevaporated):_N_o_n_e _______ _ Estimated volume of industrial wastewater to be discharged (gal/ day) : _N_o_n_e __________________ _ list hazardous wastes generated (type/volume):_N_o_n_e __________________________ _ Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? YesOoate: _____ No[!] Page 1 of 2 ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com The commercial enterprises listed below are a partial listing of businesses that are exempt from industrial wastewater discharge permitting under normal operating conditions. They are exempt because (a) they discharge no process wastewater (i.e., they only discharge sanitary wastewater with no pollutants exceeding any local limits ). and (b) they have no potential to negatively impact the EWPCF or other wastewater treatment plants in the ESS. Any questions regarding exemptions should be referred to EWA Source Control staff □ Automobile Detailers □ Barber/Beauty Shops □ Business/Sales Offices □ Cleaning Services □ Carpet/Upholstery □ Childcare Facilities □ Churches □ Community Centers □ Consulting Services □ Contractors □ Counseling Services □ Educational Services (no auto repair/film □ Financial Institutions/Services □ Fitness Centers □ Gas Stations (no car wash/auto repair) □ Grocery Stores (no film developing) □ Residential based Businesses developing) □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ Hotels/ Motels (no laundry) Laundromats Libraries Medical Offices (no x-ray developing) Mortuaries Museums Nail Salons Nursing Homes Office Buildings (no process flow) Optical Services Pest Control Services (no pesticide repackaging for sale) Pet Boarding/Grooming Facilities Postal Services (no car wash/auto repair) Public Storage Facilities Restaurants/Bars Retail/Wholesale Stores (no auto repair/film developing) Theaters (Movie/Live) CERTIFICATION STATEMENT I certfb· that !he il?formution ahovc is true and correct lo the hes! (?f"my knoll'ledge. Print Name: Logan Manning 12.16.21 Date: ____ _ Facility Contact Tom Conrad Title:_C_S_P __________ _ ENCINA WASTEWATER AUTHORITY 6200AVENIDA ENCINAS, CARLSBAD, CA Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinaj pa. com Page 2 of 2