HomeMy WebLinkAbout1728 SKIMMER CT; ; CBR2021-0686; PermitPERMIT REPORT
Residential Permit
Print Date: 05/24/2022
Job Address: 1758 SKIMMER CT, CARLSBAD, CA 92011-3609
(city of
Carlsbad
Permit No: CBR2021-0686
Status: Closed -Finaled
Permit Type: BLDG-Residential Work Class: Second Dwelling Unit
Parcel#: 2159213500 Track#:
Valuation: $9,534.55 Lot#:
Project#:
Plan#:
Occupancy Group:
#of Dwelling Units: 1
Bedrooms: Construction Type:
Bathrooms: Orig. Plan Check#:
Plan Check#:
Project Title:
Description: 205 SF CONVERSION OF SINGLE CAR GARAGE TO ADU (JADU)
Applicant:
STEVEN RATLEY
301 SCOTT ST
UKIAH, CA 95482-4319-MENDOCINO
(703) 980-8260
FEE
5B1473 GREEN BUILDING STATE STANDARDS FEE
BUILDING PERMIT FEE ($2000+)
STRONG MOTION-RESIDENTIAL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
BUILDING PLAN CHECK FEE (BLDG)
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
Total Fees: $501.67 Total Payments To Date: $501.67
Applied: 03/12/2021
Issued: 11/09/2021
Finaled Close Out: 05/04/2022
Inspector:
Final Inspection:
Contractor:
TKers
05/04/2022
CHIVAS LEE STANLEY CONSTRUCTION
2601 MASSACHUSETTS AVE
LEMON GROVE, CA 91945-3140-SAN DIEGO
(619) 251-2028
Balance Due:
AMOUNT
$1.00
$114.96
$1.24
$175.00
$41.00
$39.00
$80.47
$49.00
$0.00
Please take NOTICE that approval of your project includes the 11lmposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
( City of
Carlsbad
RESIDENTIAL
BUILDING PERMIT
APPLICATION
B-1
PI an Che ck i..,,~~'-<!,,1&!..:=1.C~,.J\J'4
Est. Value
PC Deposit
Date 3-: 12 -2t
175
JobAddress r:ptJfp ,$1;'/MME-€, C.:C: Suite: PN: 2159-213-500 ----~"
CT/Project#:. ________________ ,Lot#:. ____ vear Built: ..;2;.;0_0-0 ______ _
Fire Sprinklers,@vEsQ NO Air Conditionlng:Q YES ONO
BRIEF DESCRIPTION OF WORK:
Electrical Panel Upgrade:QYE~ NO
Conversion of single car attached garage to accessory dwelling unit (ADU) 205 sqft.
0 Additlon/New: _____ Living SF, ____ Deck SF, ____ .Patio SF, ____ Garage SF __ _
Is this to create an Accessory Dwelling Unit? @YON New Fireplace? Ov @N, if yes how many? __
Ii] Remodel:_2_05 ____ .SF of affected area Is the area a conversion or change of use ?@YON
0 Pool/Spa:. ____ SF Additional Gas or Electrical Features? N -------------
li]Solar: 1 KW, 4 Modules, Mounted:@Roof QGround, Tilt: Q Y@ N, RMA: Qy ON,
Batterv:OY @N, Panel Upgrade: Ov @N
D Reroof: ------------------------------------□ Plumbing/Mechanical/Electrical
0 Only: Other:
New mini•split heat pump is solar assisted. See Title-24 Sheets MEP .2 & MEP .3
This permit Is to be Issued In the name of the Property Owner as Owner•Bullder, licensed contractor or Authorized Agent of the
owner or contractor. The person listed as the Appfic_ant below will be the main point of contact throughout the permit process.
PROPERTY OWNER APPLICANT □
Name: Danny & Mary Beth Hernandez
Address: 1756 Skimmer Court
City: Carlsbad State: CA Zip: 92011
Phone: 973-903-1135
Email: steven@renalexander.com
DESIGN PROFESSIONAL APPLICANT Ii)
Name:Steven Ratley
Address: 301 Scott Street
City: Ukiah State: CA Zip: 95482
Phone:703-980-8260
Email: steven@renalexander.com
PROPERTY OWNERS AUTHORIZED AGENT APPLICANT 0
Name: Steven Ratley
Address: _________________ _
City:. __________ .State: ___ Zip: ____ _
Phone: __________________ _
Email: ___________________ _
CONTRACTOR OF RECORD APPLICANT 0
Name: Chivas Stanley/ CLS Construction
Address: 2603 Massachusetts Avenue
City: Lemon Grove State: CA Zip:_9_1_9_4_5 ___ _
Phone: 619-251-2028
Email: clsconstruction 100@gmail.com
Architect State License: __________ _ State License/class: 816168 Bus. License: ____ _
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov
REV. 08/20
IDENTIFY WHO Will PERFORM THE WORK BY COMPLETING (OPTION A) OR (OPTION B) BELOW:
(OPTION A): LICENSED CONTRACTOR DECLARATION:
I hereby affirm under penalty of perjury that f am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code, and my license is in full force and effect. I also affirm under penafty of perjury one of the
/of/owing declarations:
~ have and will maintain a certificate of consentto self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the 1 1
rk which this permit is issued. Policy No .. _-----------------------------------------
'liPf'have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ~ ~orkers' compensation insurance carrier and policy number are: Insurance Company Name: _____________________ _
Polley No. Expiration Date: _____________ _
~ificate of Exemption; r certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become
subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage b unlawful and shall subject an employer to
crlmlnal penalties and civil fines up to $100,000.00, In addition the to the cost of compensation, damages as provided for In Section 3706 of the Labor Code,
Interest and attorney's fees.
CONSTRUCTION LENDING AGENCY. IF ANY:
I hereby affirm that there Is a construction tendlne: agency for the perfomrnnce of the work this permit is issu9d (Sec. 3097 (I) Civil Code).
Lender's Name: IJ/Jr Lender's Address: __ ..:N.:.J.[.:.•-1'..,_ ______________ _
CONTRACTOR PRINT: Cij/{~S lnttJL.t:'f DATE: "5/"if/,uy
(OPTION B): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractors License Law for the following reason:
DI, as owner of the property or my employees w!th wages as their sole compensation, will do the work and the structure is not intended or offered for sate (Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and who does such work
himself or through his own employees, provided that such improvements are not Intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner-builder will have the burden of proving that he did not bu!ld or Improve for the purpose of sale).
0 I, as owner of the property, am exclusively contracting with lltensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
0 I am exempt under Business and Professions-Code Division 3, Chapter 9, Articl!i! 3 for this reason:
D"owner Builder acknowledgement and verification form" has been filled out, signed and attached to this application.
0 Owners •Authorized Agent Formn has been filled out, signed and attached to this application giving the agent authority to obtain the permit on the owner's behalf.
By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the
Improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if It has not been constructed in its entirety by licensed
contractors. I understand that a copy of the opp/lcoble low, Sm::.tion 7044 of the BusinPS'.i and Professions Code, is available upon reques.t when this opp/feat/on is
submitted or at the following Web site: http://www.feginfo.co.gov/calow.htmf.
OWNER PRINT: t,\~ l'ffi-1 ~AAt>fZ... DATE: 3/8/2021
APPLICANT CERTIFICATION: SIGNATURE REQUIRED AT THE TIME OF SUBMITTAL
By my signature below, I certify that: I am the property owner or State a/ California Licensed Contractor or authorized to act on the property
owner or contractor's behalf. I certify that I hove read the application and state that the above information is correct and that the information on
the plans is accurate. I agree to comply with all City ordinonces and State laws relating to building construction.
I hereby authorize representative of the City of Corlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE,
INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST All LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE
AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations aver S'O' deep and
demolition or construction of structures over 3 stories in height.
APPLICANT PRINT: Steven Ratley
163S Faraday Ave Carlsbad, CA 92008 Ph: 760•602-2719 Fa)(: 760-602-85S8 Email: Building@carlsbadca.gov
2 REV. 08/20
'
PJJlMlT lN~BECTlON HISTORY for (CBR2021-0616)
Permit Type: BLDG-Residential Application Date: 03/12/2021 Owner:
Work Class: Second Dwelling Unit Issue Date:
Status: Closed -Finaled Expiration Date:
IVR Number:
Scheduled Actual Inspection Type Inspection No.
Date Start Date
Tuesday, May 24, 2022
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
COMMENTS
11/09/2021 Subdivision: CARLSBAD TCT#99-13 STEINER
PROPERTY
09/12/2022 Address: 1758 SKIMMER CT
32059 CARLSBAD, CA 92011-3609
Inspection Primary Inspector Reinspection Inspection
Status
Passed
Yes
Yes
Yes
Yes
Yes
Page 2 of 2
Building Permit Inspection History Finaled
(city of
Carlsbad
PERMIT INSPECTION HISTORY for (CBR2021-0686)
Permit Type: BLDG-Residential Application Date: 03/12/2021 Owner:
Work Class: Second Dwelling Unit Issue Date: 11/09/2021 Subdivision: CARLSBAD TCT#99-13 STEINER
PROPERTY
Status: Closed -Finaled Expiration Date: 09/12/2022 Address: 1758 SKIMMER CT
IVR Number: 32059 CARLSBAD, CA 92011-3609
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
01/13/2022 01/13/2022 BLDG-SW-Pre-Con 174521-2022 Passed Tim Kersch Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
01/28/2022 01/28/2022 BLDG-21 175489-2022 Passed Tim Kersch Complete
Underground/U nderflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
02/03/2022 02/03/2022 BLDG-11 175926-2022 Passed Tim Kersch Complete
Fou n datio n/Ftg/P iers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
03/10/2022 03/10/2022 BLDG-84 Rough 178101-2022 Passed Tim Kersch Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
03/14/2022 03/14/2022 BLOG-16 Insulation 178246-2022 Passed Tim Kersch Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
03/16/2022 03/16/2022 BLDG-18 Exterior 178453-2022 Passed Tim Kersch Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
05/04/2022 05/04/2022 BLDG-Final Inspection 181951-2022 Passed Tim Kersch Complete
Tuesday, May 24, 2022 Page 1 of 2
DATE: 4/28/2021
JURISDICTION: Carlsbad
PLAN CHECK#.: CBR2021-0686
✓• EsG1I
SET II
PROJECT ADDRESS: 1758 Skimmer Court
PROJECT NAME: Garage Remodel to ADU
□ APPLICANT
□ JURIS.
[g] The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person. D The applicant's copy of the check list has been sent to:
[g] EsGil staff did not advise the applicant that the plan check has been completed.
D EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone#:
Date contacted: (by: Email:
Mail Telephone Fax In Person
0 REMARKS:
By: Richard Moreno. Phone: 858-345-6435
EsGil
4/20/2021
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
✓• EsG1I
DATE: 3/20/2021 □ APPLICANT
□ JURIS.
JURISDICTION: Carlsbad
PLAN CHECK#.: CBR2021-0686
PROJECT ADDRESS: 1758 Skimmer Court
PROJECT NAME: Garage Remodel to ADU
SETI
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to:
Stephen Ratley
D EsGil staff did not advise the applicant that the plan check has been completed.
~ EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Stephen Ratley Telephone#: 703-980-8260
Date contacted: (by: ) Email: steven@renalexander.com
Mail Telephone Fax In Person
0 REMARKS:
By: Richard Moreno. Phone: 858-345-6435
EsGil
3/16/2021
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad CBR2021-0686
3/20/2021
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK#.: CBR2021-0686 JURISDICTION: Carlsbad
PROJECT ADDRESS: 1758 Skimmer Court
FLOOR AREA:
Remodel: 205 SF
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
858-345-6435
COMPLETED: 3/20/2021
FOREWORD (PLEASE READ):
STORIES: 1
HEIGHT: existing
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 3/16/2021
PLAN REVIEWER: Richard Moreno. Phone:
This plan review is limited to the technical requirements contained in the California Residential
Code, California Building Code, California Plumbing Code, California Mechanical Code,
California I Electrical Code and state laws regulating energy conservation, noise attenuation and
access for the disabled. This plan review is based on regulations enforced by the Building
Department. You may have other corrections based on laws and ordinance by the Planning
Department, Engineering Department, Fire Department or other departments. Clearance from
those departments may be required prior to the issuance of a building permit.
Present California law mandates that construction comply with the 2019 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2019 CRC, 2019 CBC,
2019 CPC, 2019 CMG and 2019 CEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2019 California Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad CBR2021-0686
3/20/2021
GENERAL RESIDENTIAL REQUIREMENTS
1. There shall be a landing or floor on each side of each exterior door. The width of
each landing shall be not less than the door served. Every landing shall have a
dimension of not less than 36 inches measured in the direction of travel. The
slope at exterior landings shall not exceed¼ unit vertical in 12 units horizontal (2
percent). Landing shall be not more than 7-3/4 inches below the top of the
threshold. R311.3.
2. Provide a note on the plans stating: "Penetrations of fire-resistive walls, floor--
ceilings and roof-ceilings shall be protected as required in CRC Section R302.4."
3. Walls and floors separating units in a duplex shall have a sound transmission
class (STC) of not less than 50. Additionally, floors must have an impact
insulation class (IIC) rating of not less than 50. CBC Section 1207. Show the
location of and provide details of the listed wall and floor/ceiling assemblies and
indicate the listing agency and listing number for the tested ratings.
4. Floor assemblies separating units in a duplex shall be of one-hour fire resistive
construction (½-hour if the building has an automatic sprinkler system). Provide
details of the assemblies. Section R302.3. Such assemblies shall extend to and
be tight to the exterior wall, where applicable.
5. Unless Garage is for the sole usage of ADU tenant, walls between garage and
ADU must be fire and sound rated.
6. The supporting construction of fire-rated floor assemblies shall have an equal or
greater fire-rating. Section R302.3.1.
7. Show location of existing water heater to be used for AU. Note that ADU tenant
must have access to controls as well as a shut off valve made readily accessible.
ROOFS/DECKS/BALCONIES
8. Show the required ventilation for attics (or enclosed rafter spaces formed where
ceilings are applied directly to the underside of roof rafters). The minimum vent
area is 1 /150 of attic area ( or 1 /300 of attic area if at least 40% (but not more
than 50%) of the required vent is located no more than 3' below the ridge) and
remaining vents located at the lower third of the of the attic space. Show on the
plans the area required and area provided. Section R806.2.
a) When using a radiant barrier, California energy design affects the attic
ventilation area requirement: If using the Prescriptive method for energy
compliance, then the attic vent area must be at the 1/150 area: If using
the Performance method, either the 150 or 300 areas may be used, as
documented on the energy forms. Section RA4.2.1.
Carlsbad CBR2021-0686
3/20/2021
MISCELLANEOUS
9. To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
10. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes □ No □
11. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Richard Moreno. Phone: 858-345-6435
at EsGil. Thank you.
"Carlsbad CBR2021-0686
3/20/2021
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK#.: CBR2021-0686
PREPARED BY: Richard Moreno. Phone: 858-345-6435
BUILDING ADDRESS: 1758 Skimmer Court
BUILDING OCCUPANCY:
BUILDING AREA Valuation Reg.
PORTION ( Sq. Ft.) Multiplier Mod.
remodel 205
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
1997 UBC Buildin Permit Fee 9 ,..
1997 UBC Plan Check Fee •
DATE: 3/20/2021
VALUE ($)
9,534
9,534
I !\I' 01
Type of Review: [7] Complete Review D Structural Only
D Repetitive Fee
,.. Repeats
D Other
D Hourly
EsGil Fee
Comments: In addition to the above fee, an additional fee of$
$ /hr.) for the CalGreen review.
$74.481
is due ( hour@
Sheet 1 of 1
( City of
Carlstiad
PURPOSE
CLIMATE ACTION PLAN
CONSISTENCY CHECKLIST
B-50
Development Services
Building Division
1635 Faraday Avenue
(760) 602-2719
www.carlsbadca.gov
This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance
requirements apply to their projects. The completed checklist must be included in the building permit application. It may be
necessary to supplement the completed checkl.ist with supporting materials, calculations or certifications, to demonstrate
full compliance with CAP ordinance requiremenis. For example, projects that propose or require a performance approach
to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as
specified by the ordinances.
NOTE: The following type of permits are not required to fill out this form
❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool
_. If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance,
an explanation must be provided to the satisfaction of the Building Official.
_. Details on CAP ordinance requirements are available on the city's website .
.,; A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be
completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and
download the latest form.
~ ~ . --~----~ -~~-,--=--~. --.
1, I ' J )
Project Name/Building
PenmitNo.: 1756 Skimmer Court BP No.: ~202\-0U/~ U)
Property Address/APN: 2159-213-500
Applicant Name/Co.: Steven Ratley
Applicant Address: 301 Scott Street, Ukiah, CA 95482
Contact Phone: 703-980-8260 Contact Email: Steven@renalexander.com
Contact information of person completing this checklist (if different than above):
Name:
Company
name/address:
Applicant Signature: s~ ~
B-50
Contact Phone:
Contact Email:
Date: 3/8/2021
Page 1 of6 Revised 06118
PERMIT REPORT
Revision Permit
Print Date: 05/24/2022
Job Address: 1758 SKIMMER CT, CARLSBAD, CA 92011-3609
(city of
Carlsbad
Permit No: PREV2021-0149
Status: Closed -Finaled
Permit Type: BLDG-Permit Revision
2159213500
$9,534.55
Work Class: Residential Permit Revisit
Parcel#:
Valuation:
Occupancy Group:
#of Dwelling Units: 1
Bedrooms:
Bathrooms:
Project Title:
Track#:
Lot#:
Project#:
Plan#:
Construction Type:
Orig. Plan Check#: CBR2021-0686
Plan Check#:
Description: GARAGE DOOR OF JADU BEING REMOVED AND IN FILLED WITH STUCCO
Applicant:
STEVEN RATLEY
301 SCOTT ST
UKIAH, CA 95482-4319-MENDOCINO
(703) 980-8260
FEE
BUILDING PLAN REVIEW -Revisions
Total Fees: $64.50 Total Payments To Date: $64.50
Applied: 12/09/2021
Issued: 12/09/2021
Fina led Close Out: 05/24/2022
Inspector:
Final Inspection:
Contractor:
CHIVAS LEE STANLEY CONSTRUCTION
2601 MASSACHUSETTS AVE
LEMON GROVE, CA 91945-3140-SAN DIEGO
(619) 251-2028
Balance Due:
AMOUNT
$64.50
$0.00
1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
("city of
Carlsbad
PLAN CHECK REVISION OR
DEFERRED SUBMITTAL
APPLICATION
B-15
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
Original Plan Check Number CBR2021 -0686 Plan Revision Number _2 _______ _
ProjectAddress 1756 Skimmer Court
General Scope of Revision/Deferred Submittal: infill ( e) garage door with stucco wall
CONTACT INFORMATION:
Name Kathy Scura Phone ________ Fax~--------
Address 1758 Skimmer Court City Carlsbad Zip 92011
Email Address kathy scura@yahoo.com
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person.
1 . Elements revised: Ii] Plans D Calculations D Soils D Energy D Other
2. 3.
Describe revisions in detail List page(s) where each
revision is shown
garage door of JADU being removed entirely and infilled with new stucco 2x4 framed wall in opening. A2.1, A3.1, A5.1
4. Does this revision, in any way, alter the exterior of the project? Ii] Yes 0 No
5. Does this revision add ANY new floor area(s)? D Yes D No
6. Does this revision affect any fire related issues? D Yes Ii] No
7. Is this a complete set? D Yes Ii] No
St R ti Digitally signed by Steven Ratley 12/2/2021 A".S'Signature even a ey Date: 2021.12.02 1246:05 -08'00' Date
1635 Faraday Avenue, Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: building@carlsbadca.gov
www.carlsbadca.gov