1896 RUTHERFORD RD; ; CBC2021-0377; Permit
PERMIT REPORT Commercial Permit Print Date: 05/31/2022 Job Address: 1896 RUTHERFORD RD, CARLSBAD, CA 92008-7326 PermitType: Parcel#: Valuation: BLDG-Commercial 2121203000 $377,196.10 Occupancy Group: 5-1, F-1, B #of Dwelling Units: Work Class: Track#: Lot#: Project#: Plan#: Tenant Improvement Bedrooms: Bathrooms: Construction Type:VB Orig. Plan Check#: Plan Check#: Project Title: Description: ARGONAUT MANUFACTURING: 8,110 SF T.I. Applicant: Property Owner: KDG ARCHITECTURE KIMBERLY KRENEK 6520 NANCY RIDGE DR SAN DIEGO, CA 92121-2250 (858) 558-5935 FEE FIRE F Occupancies Tl BUILDING PLAN CHECK FEE (manual) PD G CARLSBAD 46 LIMITED 1896 RUTHERFORD RD CARLSBAD, CA 92008 BUILDING PLAN REVIEW-MINOR PROJECTS (LDE) BUILDING PLAN REVIEW -MINOR PROJECTS (PLN) GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION SB1473-GREEN BUILDING STATE STANDARDS FEE STRONG MOTION -COMMERCIAL (SMIP) COMM/IND Tl -STRUCTURAL Total Fees: $4,238.93 Total Payments To Date: $4,238.93 (city of Carlsbad Permit No: CBC2021-0377 Status: Closed -Finaled Applied: 09/27/2021 Issued: 11/15/2021 Finaled Close Out: 04/25/2022 Inspector: Final Inspection: Balance Due: TAlva 04/25/2022 AMOUNT $691.00 $2,361.51 $194.00 $98.00 $175.00 $16.00 $105.61 $597.81 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov ( City of Carlsbad COMMERCIAL BUILDING PERMIT APPLICATION B-2 Plan Chec~&?D,-x /, 037'1- Est. Value f/J 5·-r1, LQ<o. tD PC Deposit Date q /,;J:f /;i.J Job Address 1896 RUTHERFORD ROAD Tenant Name: ARGONAUT MANUFACTURING Year Built:_19_9_6 ___ Occupancy: s-1,F-1,8 • • Suite:. ____ APN: 212-120-62 Lot#: _46_;_ ______ _ VB . . EJD EJD Construction Type· Fore Sprinklers: yes ao ~C: yes ao BRIEF DESCRIPTION OF WORK: CONVERSION OF 8,110 S.F. OFFICE AREAS TO MANUFACTURING AREAS. D Addition/New: ___________ New SF and Use, ___________ New SF and Use, ___ Deck SF, Patio Cover SF (not including flatwork) [!] Tenant lmprovement:,_8.;.., 1_1o ____ SF, Existing Use_B ______ Proposed Use _F_-1 ____ _ _____ SF, Existing Use Proposed Use ______ _ D Pool/Spa.: _____ SF Additional Gas or Electrical Features?_---==-==--------,= DD DD DD D Solar_: ____ KW,, ___ Modules,, ___ Mounted, Tilt: Yes/ No, RMA: Yes/ No, Panel Upgrade: Yes/ No D Plumbing/Mechanical/Electrical Only: -------------------------- □ Other: This permit is to be issued in the name of the Property owner as Owner-Builder, licensed contractor or Authorized Agent of the owner or contractor. The person listed as the Applicant below will be the main point of contact throughout the permit process. PROPERTY OWNER APPLICANT O PROPERTY OWNERS AUTHORIZED AGENT APPLICANT 0 Name: ROB TSCHANTZ, DIVERSIF!ED PROPERTIES Address:5O5 LOMAS SANTA FE DRIVE Name: __________________ _ Address: _________________ _ City: SOLANA BEACH State:,_C_A __ Zip: 92075 City:. _________ ~State: ___ Zip:. ____ _ Phone: (619) 258-2900 EXT. 304 Phone:------------------- Email: _________________ Email: __________________ _ DESIGN PROFESSIONAL Name: KIMBERL y KRENEK Address: 6520 NANCY RIDGE DRIVE APPLICANT Ii] City: SAN DIEGO State.:_ c_A __ Zip: 92121 Phone: 858-558-5935 Email: KIMBERLY@KRENEKDESIGN.COM CONTRACTOR BUSINESS APPLICANT 0 Name:. __________________ _ Address:. _________________ _ City:. ________ State:. ___ Zip:. _____ _ Phone:. __________________ _ Email:. __________________ _ Architect State License: _C_2_6_7_86________ State License:. ______ Bus. License:. ______ _ 1635 Faraday Ave Carlsbad, CA 92008 8-2 Ph: 760-602-2719 Fax: 760-602-8558 Page 1 o/2 Email: Building@carlsbadca.gov Rev_ 08/20 IDENTIFY WHO WILL PERFORM THE WORK BY COMPLETING (OPTION A) OR (OPTION B) BELOW: (OPTION A): LICENSED CONTRACTOR DECLARATION: I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. I also affirm under penalty of perjury one of the Jo/lawing declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. Policy No. _________________________ _ 01 have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensaf1on insurance carrier and policy number are: Insurance Company Name: ___________________ _ Polley No .. ______________________ Expiration Date: ____________________ _ D Certificate of Exemption: I certify that in the petiormance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and stlall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition ttle to ttle cost of compensation, damages as provided for in Section 3706 of the Labor Code, Interest and attorney's fees. CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: _____________________ ,Lender's Address: _____________________ _ CONTRACTOR PRINT: ________ _ SIGN: _________ DATE: ______ _ (OPTION B): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License law for the following reason: DI, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Profess·1ons Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) 01, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Profess·1ons Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects wrth contractor(s) licensed pursuant to the Contractor's License Law). 01 am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason: II "Owner Builder acknowledgement and verification form" has been filled out, signed and attached to this application. Proof of identification attached. D Owners "Authorized Agent Form'' has been filled out, s·1gned and attached to this application giving the agent authority to obtain the permit on the owner' behalf. Proof of identification attached. By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed contractors. I understand that a copy of the applicable law, Section 7044 of the Busi~essions Code, is available upon request when this application is ,ubminedocatthefollo;~~•~;~:=~:wwlegiofowgo,/calawhtml /? ~C ~--9116121 OWNER PRINT: ____________ '51GN:. _______ .,£D"--DAATTEE:: ______ _ APPLICANT CERTIFICATION: SIGNATURE REQUIRED AT THE TIME OF SUBMI? By my signature below, I certify that.· I am the property owner or State of California Licensed Cantmctor or authorized to act on the property owner or contractor's behalf I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with al/ City ordinances and State laws relating to building construction. I hereby authorize representative of the Oty of Carlsbad to enter upon the above mentioned property far inspection purposes. I ALSO AGREE TO SA VE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations aver 5'0' deep and demolition or construction of structures aver 3 stories in height. Eric Benson APPLICANT PRINT: _________ _ ~~/ DA 9/16/21 SIGN: ...c;~;._ ___ ,_-_ ~---TE: _____ _ 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-2 Page 2 of 2 Rev. 08120 l_ City of Carlsbad OWNER-BUILDER ACKNOWLEDGEMENT FORM B-61 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov OWNER-BUILDER ACKNOWLEDGMENT FORM Pursuant to State of California Health and Safety Code Section 1982S-19829 To: Property Owner An application for construction permit(s) has been submitted in your name listing you as the owner-builder of the property located at: site Address 1896 Rutherford Road, Carlsbad, California 92008 -(PDG Carlsbad 46, Ltd.) The City of Carlsbad ("City'') is providing you with this Owner-Builder Acknowledgment and Verification form to inform you of the responsibilities and the possible risks associated with typical construction activities issued in your name as the Owner-Builder. The City will not issue a construction permit until you have read and initialed your understanding of each provision in the Property Owner Acknowledgment section below and sign the form. An agent of the owner cannot execute this notice unless you, the property owner, complete the Owner's Authorized Aaent form and It Is accepted by the City of Carlsbad. INSTRUCTIONS: Please read and initial each statement below to acknowledge your understanding and verification of this information by signature at the bottom of the form. These are very important construction related acknowledgmE"nts des1gr;t:>d ~o inform the property owner of his/her obligations related to the requested permit activities. I. RT I understcri,:J ,, frr-,i_ ,, ,-! i-.· _.,,.'.1··2 ,:~ 1o11:( • n::~_•d contractors is to have the property owner obtain an "Owner Builder" bui!dinf!: 1,.,,1: -1 • 1 . t . , .-· -:, ,,,.<.1,.-1rn.,.1e·, th.:it the property owner is providing his or her own labor and material persona1:·: i. · ·-1· _1,,~ .. te, 6L"ild•.'r, (Tl.l\' b0 held iiable and subject to serious financial risk for any Injuries sustained by an unticcrsed c.,,~tnc ccr 311J ),;~ nr her employees while working on my property. My homeowner's insurance may not pi c,vide COVf'r;;.ge iin ,~:o':ie 1111uries. I am willfully acting as an Owner-Builder and am aware of the limits of mv insurance cover..~e for injuries to workers on my property. II. RT I understand building permit'> ore 11ot n:,qlJirPd to be signed by property owners unless they are responsible for the construction and arc not t~lr1·1g .i li;ensed contractor to assume this responsibility. 111. RT _I understand a.s an ''Owr:1;;:r-Butlder" I am the responsible party of record on the permit. l understand that I may protect my,;;eif from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own. IV. RT I undersland r.:or,tr.JCtc,r:. ;-, ,, ;:'L~uin-:d b1; law to be licensed and bonded in California and to list their license numbers on permit:, 2nd c'.:.i,ii.i'c<.:' V. RT I underst2nd if I te'1P1.•by Pr o:h.•1""11,'.e Pr,g12e c1ny persons, other than California licensed contractors, and the total value ot my { o-, ,tl'1,-:rJ.1 ·, ;;t ii:·~; five ~11.,r1dred dollars ($500), including labor and materials, I may be considered an "ernplQ\ll'I :,,,, •r ·,·.-i .-. ;,·,,.i tedc'11\ law. REV. 08/20 Owru,"r·-Builder Acknowlt:-dgement Continued VL RT I understand if lam considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. Vil. RT I understand under California Contractors' State license Law, an Owner~Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building contractor. VIII. RT I understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) which result from any latent construction defects in the workmanship or materials. IX. RT I understand I may obtain more information regarding my obligations as an "employer" from the Intern a I Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State license Board (CSLB) at 1·-800~321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. X. RT I am aware of and consent to an Owner-Builder building permit applied for in my name, and understand that 1 am the party legally and financially responsible for proposed construction activity at the following address: 1896 Rutherford Road, Carlsbad, California 92008 XI. RT I agree that, as the pc1rty leGally and f1n,mci ~lly rt•s;ponsible for this proposed construction activity, I will abide by all applicable law~ ,1nd rcquirpments thilt r,(1,2rn Owner•Builders as well as employers. XII. RT I agree to not,! y the issuer of this forn, ,:111 · ,i_~d1 )lcly of any additions, deletions, or changes to any of the information I have r1rwided ori 1.• ,., torrn. licensed contrac1u'., ,3re reg.il.-1,. ,! i_,.., ! 11, does not have •1 lkensc, th~ C,:;,-,t.-., 1, • you may sustain a~. a result (lf ,'I -:-c, It is also impo,tant fr.ir y·ou to t.w,i,.,,~,"·1·, •'.- is injured while we, ~-1r,g on your f.lrDp: rt,· · ·· l'. a, prott'ct the public. If you contract with someone who •'1 •_, • .'loard may be unable to assist you with any financial loss )1', v r ;· 1; 1 · ·1:!y against unlicensed Contractors may be in civil court. · il:1~nsed Contractor or employee of that individual or firm : 1 ''f· f·,,_,ld liable for damages. If you obtain a permit as Owner- Builder and wish to h'r2 ~on tractor:., )'O'J 1N1II be '•'..ij-1)nsible for verifying whether or not those contractors are properly licensed and the statllS of th':'ir w~1tkH~ '-Ornpensalion(overage. Before a building permit can be issued, this form must be completed, signed by the property owner and returned to the City of Carls bod BuiJding Division. I dee/ore under penalty of perjury that I hove read and undentond o/1 of the mformorwn provided on this form ond t110C fl'W respomes, including my aufhor;ty fO sign !his form, is true and correct I om aware !hat I hove the apr,on to consult with ll'gol counsel prior to siymng this form, and I hove either (1) consulted with /ego/ counsel prior fo signing this form or{l) have waived fhi,. nghr m Sl!Jmng this form witlwuf the advice of /ego/ coumcL REV. 08/20 ( City of Carlsbad OWNERS AUTHORIZED AGENT FORM B-62 Development Services Building Division 163S Faraday Avenue 760-602-2719 www.cartsbadca.gov OWNER'S AUTHORIZED AGENT FORM OnJy a property owner, contractor or their authorized agent may submit pfans and app/lcat;ons for building permits. To authorize a third-party agent to sign for a building permit, the owner's third party agent must bring this signed form, which identifies the agent and the owner who s/he Is representing, and for what jobs s/he may obtain permits. The form must be completed in its entirety to be accepted by the City for each separate permit application. Note: The following Owners Authr,rized Agent form Is required to be completed by th« property owner only when d~!>fgnating an agent to apply for a construction permit an his/her behalf. Al.JJHCL~"' or:AG_E~;,T re t-,g_u:-.: ri~,· Excluding the Property 01'-'1:i,~ ,,,,; «nuw1,:,,. P_, I hereby authoriw th'":' f .)/:_,, •.. :•[:. .,::..rsor·,'._;· to obtain an Owner-~u1lf)f:" ,·;•r·r ·; i,:H· n''.11 ._._ ,; > '.2.~lL ,., 1f ,,'lhich I understand is my personal responsibility, .· e1~01y for, sign, and file the documents necessary Scope of Construction Project (or Desi;;riptiol"', m V ·.:·it; Project Location or Addcessc _,.c/8"----9._0=._ -;2.u-fl-e,_ W £.:,o/ Name of Authorized Agent: _ _,£.::__;_r..:1c.l'.. __ ~,__lc._:::.;__=.,,,,.-,=...:__ _______ Tel No. Address of Authorized Agent: _____________________________ _ I declare under penalty of perjury that I a out the above information and certify· accur property owner for the address listed above and I personally filled y. PERMIT INSPECTION HISTORY for (CBC2021-0377) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Application Date: 09/27/2021 Issue Date: 11/15/2021 Owner: P D G CARLSBAD 46 LIMITED Subdivision: CARLSBAD TCT#85-24 UNIT#03 Address: 1896 RUTHERFORD RD Status: Closed -Finaled Expiration Date: 10/05/2022 IVR Number: 36148 CARLSBAD, CA 92008-7326 Scheduled Date 03/29/2022 04/08/2022 04/25/2022 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector 03/29/2022 04/08/2022 04/25/2022 Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS Rough electrical work done in electrical room for three electrical panel feeding electrical panels make-up work-partial pass. February 15, 2022: 1. Rough electrical for electrical room make-up electrical panels. 2. (3) total quantity electrical panels and transformer, torqued lugs-Approved per Electrical engineer's plans and single line diagram, sheet E.801-approved. BLDG-44 179289-2022 Passed Tony Alvarado Rough/Ducts/Dampers Checklist Item COMMENTS BLOG-Building Deficiency Duct sealant, LEED qualified product at all mechanical air ducting connections - approved. BLDG-85 T-Bar, Celling 180055-2022 Passed Tony Alvarado Grids, Overhead Checklist Item COMMENTS BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLOG-24 Rough-Topout BLOG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers BLDG-Final Inspection 181260-2022 Passed Tony Alvarado Checklist Item COMMENTS BLOG-Plumbing Final BLOG-Mechanical Final BLDG-Structural Final BLOG-Electrical Final Tuesday, May 31, 2022 Reinspection Inspection Passed Yes Yes Complete Passed Yes Complete Passed Yes Yes Yes Yes Complete Passed Yes Yes Yes Yes Page 5 of 5 PERMIT INSPECTION HISTORY for (CBC2021-0377) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Application Date: 09/2712021 Issue Date: 1111512021 Owner: P D G CARLSBAD 46 LIMITED Subdivision: CARLSBAD TCT#85-24 UNIT#03 Address: 1896 RUTHERFORD RD Status: Closed -Finaled Expiration Date: 10105/2022 IVR Number: 36148 CARLSBAD, CA 92008-7326 Scheduled Date 01/27/2022 02/15/2022 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector 01/27/2022 02/15/2022 BLDG-34 Rough Electrical Checklist Item 175316-2022 COMMENTS Passed Tony Alvarado BLDG-Building Deficiency January 25, 2022: BLDG-44 Rough/Ducts/Dampers Checklist Item 1. Metal framing, metal ceiling joist scope of work for phase 2-approved. 2. Mechanical vertical walls Plenum ducting -duct sealant scope of work-approved. 3. Interior insulation at vertical non-loadbearing partition walls-approved. 4. Rough electrical through walls and ceiling at all interior office, clean room, and lab areas -approved. 175339-2022 Passed Tony Alvarado COMMENTS BLDG-Building Deficiency January 25, 2022: 1. Metal framing, metal ceiling joist scope of work for phase 2-approved. 2. Mechanical vertical walls Plenum ducting -duct sealant scope of work-approved. 3. Interior insulation at vertical non-loadbearing partition walls-approved. 4. Rough electrical through walls and ceiling at all interior office, clean room. and lab areas -approved. BLDG-Building Deficiency December 28, 2021: BLDG-17 Interior Lath/Drywall BLDG-34 Rough Electrical Checklist Item 1. Metal framing, scope of work for mezzanine areas to accommodate new HVAC mechanical units-approved. 2. Mechanical rooftop Plenum ducting - duct sealant scope of work-approved. 3. Mezzanine platform plywood fastener anchoring pattern-approved. 175512-2022 Partial Pass Tony Alvarado 175412-2022 Partial Pass Tony Alvarado COMMENTS BLDG-Building Deficiency Rough electrical work done in electrical room for three electrical panel feeding electrical panels make-up work-partial pass. BLDG-34 Rough 176670-2022 Partial Pass Tony Alvarado Electrical Tuesday, May 31, 2022 Reinspection Inspection Complete Passed Yes Complete Passed Yes Yes Reinspection Incomplete Re inspection Incomplete Passed Yes Reinspection Incomplete Page 4 of 5 PERMIT INSPECTION HISTORY for (CBC2021-0377) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Application Date: 09/27/2021 Issue Date: 11/15/2021 Owner: P D G CARLSBAD 46 LIMITED Subdivision: CARLSBAD TCT#85-24 UNIT#03 Address: 1896 RUTHERFORD RD Status: Closed -Finaled Expiration Date: 10/05/2022 IVR Number: 36148 CARLSBAD, CA 92008-7326 Scheduled Date 01/25/2022 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector Checklist Item BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-34 Rough Electrical COMMENTS L YO section/phase of dry-room/clean room; a) rough combination vertical walls. b) shear wall anchoring pattern. c) scope of work per engineer's plans-approved. d) OK to cover walls with gypsum board. L YO section/phase of dry-room/clean room; a) rough combination vertical walls. b) shear wall anchoring pattern. c) scope of work per engineer's plans-approved. d) OK to cover walls with gypsum board. 01/25/2022 BLDG-14 175338-2022 Passed Tony Alvarado Frame/Steel/Bolting/We !ding (Decks) Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS December 28, 2021: 1. Metal framing, scope of work for mezzanine areas to accommodate new HVAC mechanical units-approved. 2. Mechanical rooftop Plenum ducting - duct sealant scope of work-approved. 3. Mezzanine platform plywood fastener anchoring pattern-approved. January 25, 2022: 1. Metal framing, metal ceiling joist scope of work for phase 2-approved. 2. Mechanical vertical walls Plenum ducting -duct sealant scope of work-approved. 3. Interior insulation at vertical non-loadbearing partition walls-approved. 4. Rough electrical through walls and ceiling at all interior office, clean room, and lab areas -approved. BLDG-16 Insulation Checklist Item 175340-2022 COMMENTS Passed Tony Alvarado BLDG-Building Deficiency January 25, 2022: 1. Metal framing, metal ceiling joist scope of work for phase 2-approved. 2. Mechanical vertical walls Plenum ducting -duct sealant scope of work-approved. 3. Interior insulation at vertical non-loadbearing partition walls-approved. 4. Rough electrical through walls and ceiling at all interior office, clean room, and lab areas -approved. Tuesday, May 31, 2022 Reinspection Inspection Passed Yes Yes Complete Passed Yes Yes Complete Passed Yes Page 3 of 5 PERMIT INSPECTION HISTORY for (CBC2021-0377) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Application Date: 09/27/2021 Issue Date: 11/15/2021 Owner: P D G CARLSBAD 46 LIMITED Subdivision: CARLSBAD TCT#85-24 UNIT#03 Address: 1896 RUTHERFORD RD Status: Closed -Finaled Expiration Date: 10/05/2022 IVR Number: 36148 CARLSBAD, CA 92008-7326 Scheduled Date 01103/2022 01/04/2022 01/18/2022 Actual Inspection Type Start Date BLDG-44 Rough/Ducts/Dampers Checklist Item Inspection No. 173480-2021 COMMENTS Inspection Status Primary Inspector Partial Pass Tony Alvarado BLDG-Building Deficiency December 28, 2021: 1. Metal framing, scope of work for mezzanine areas to accommodate new HVAC mechanical units-approved. 2. Mechanical rooftop Plenum ducting - duct sealant scope of work-approved. 3. Mezzanine platform plywood fastener anchoring pattern-approved. 01103/2022 BLDG-23 173747-2021 Partial Pass Tony Alvarado Gas/TesURepairs Checklist Item BLDG-Building Deficiency COMMENTS January 3, 2022: 1. Medium pressure 24-hour gas test established-partial pass. 01/04/2022 BLDG-23 173864-2022 Passed Tony Alvarado Gas!Test/Repairs Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS January 3, 2022: 1. Medium pressure 24-hour gas test established-partial pass. January 4, 2022: 1. Medium pressure 24-hour gas test completed-approved. 01/18/2022 BLDG-13 Shear Panels/HD (ok to wrap) 174667-2022 Partial Pass Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS L YO section/phase of dry-room/clean room; a) rough combination vertical walls. b) shear wan anchoring pattern. c) scope of work per engineer's plans-approved. d) OK to cover walls with gypsum board. BLDG-84 Rough Combo(14,24,34,44) 174668-2022 Passed Tony Alvarado Tuesday, May 31, 2022 Reinspection Inspection Reinspection Incomplete Passed Yes Reinspection Incomplete Passed No Complete Passed Yes Yes Reinspection Incomplete Passed Yes Complete Page 2 of 5 Building Permit Inspection History Finaled ( City of Carlsbad PERMIT INSPECTION HISTORY for (CBC2021-0377) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Application Date: 09/27/2021 Issue Date: 11/15/2021 Owner: PD G CARLSBAD 46 LIMITED Subdivision: CARLSBAD TCT#85-24 UNIT#03 Address: 1896 RUTHERFORD RD Status: Closed -Finaled Expiration Date: 10/05/2022 IVR Number: 36148 CARLSBAD, CA 92008-7326 Scheduled Date 12/15/2021 12/2812021 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector 12/15/2021 BLDG-21 172822-2021 Partial Pass Tony Alvarado Underground/Underflo or Plumbing Checklist Item BLDG-Building Deficiency COMMENTS December 15, 2020: Point of connection for Underground sewer waste and vent and underground plumbing for sink, under water leak pressure test-approved. Partial pass-corridor metal stud framing and rough electrical work N approved. OK to cover. BLDG-22 Sewer/Water Service 172816-2021 Partial Pass Tony Alvarado Checklist Item BLDG-Building Deficiency COMMENTS December 15, 2020: Point of connection for Underground sewer waste and vent and underground plumbing for sink, under water leak pressure test-approved. Partial pass-corridor metal stud framing and rough electrical work N approved. OK to cover. BLDG-84 Rough Combo(14,24,34,44) 172823-2021 Partial Pass Tony Alvarado Checklist Item BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-34 Rough Electrical COMMENTS 12/28/2021 BLDG-14 173530-2021 Partial Pass Tony Alvarado Frame/Steel/Bolting/We lding (Decks) Checklist Item BLDG-Building Deficiency COMMENTS December 28, 2021: 1. Metal framing, scope of work for mezzanine areas to accommodate new HVAC mechanical units-approved. 2. Mechanical rooftop Plenum ducting - duct sealant scope of work-approved. 3. Mezzanine platform plywood fastener anchoring pattern-approved. Tuesday, May 31, 2022 Reinspection Inspection Reinspection Incomplete Passed Yes Roinspection Incomplete Passed Yes Reinspection Incomplete Passed Yes Yes Reinspection Incomplete Passed Yes Page 1 of 5 SPECIAL INSPECTIO~ AGREEMENT I 8-45 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov In accordance with Ch pier 17 of the California Building Code the following murt be completed when work being performed requires special inspeq!tion, structural observation and conatructfon material tatting. ' ' Project Address: !B,c, 1-ujnilSIZ-fofQ ~ A. THIS SECTION MUST JE COMPLETED BY THE PROPERTY OWNERIAUTHORJZflD AGENT. Please check ff you are Owner-BuHder □. (If you checked as OVj"er-builder you must also complete Section B of this agreemf"t.) Name: (Please print) i C::,,r; "-J . J (First) (M.I.) MailingAddres · ,I 9{, k'_.,,__--\\,-_e<-¼>,.},, "'-~ ls. "-2>- Email· ah-2 0::,.q,:---G;, QCc~<-"-1.A---+ wy-, , c 0\/\0 hone: 76a 4"1 "> L/ 761, I am: □Property Ow~er laProperty Owner's Agent of Record □Architelt of Record □Engineer of Record State of California Registration Numbe~-------------E\xpiration Oate: _______ _ I AGREEMENT: I, the updersigned, declare under penalty of perjury under the\aws of the State of California, that I have read, understand, acknowle<:jge and promise to comply with the City of Carlsbad equirements for special inspections, structural observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of special inspections notjad on the approved planl,jlnd, as required by the Calif1rnia Building Code. Signature· ~ Dale: 7.1..,-:x;:IL \ I 8. CONTRACTOR'S STATl!MENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1r06J. This section must be completed by the contractor I builder/ owner-builder. I Contractor's Compa~~ame: / 1-1utrv&~,V£. Cm"'iri4z(!.:rtll<IStadr,~,ease check tt vou are Owner-Buikler D Name: (Please print) J') IC-~ I E Ult,(() fFitsl) (MI.) (Last) Mailing Address 9jEC..\ C-t4cb{!-['ffo~ l£. ;#: t%' ZJ pa a Dr ~C\, Cl'l '1 Z( 2.3 Email C I C~ (P IC..';:, -'& ~ • <:'.?~(Ci P'one 8Sf3 -C 'f 2--7089 State of California Conti-actor's License Number: 8"tj b s3 Eipiration Date: Oj {30 /').C:>?,3 • I acknowledge a,nd, am aware, of special requirements contained in the statement of special inspections noted on the approved plans: '1 • I acknowledge jhat control will be exercised to obtain conformance wim the construction documents approved by the building official; , • I will have in-pl<jce procedures for exercising control within our (the co1tractor's) org;anzation, for the method and frequency of nep~rting and the distribution of the reports: and . • I certify that I wi/1 have a qualified person within our (the contractor's) or9anization to exercise such control. • I w/11 provide @\final report/ letter in compliance with CBC Section' 1704.1.2 prior to requesting final Signatu::s~-~ '--:, ~. 7? O~te /<?{U-/'1.P~/ 8-45 Page 1 of 1 Rev. 08/11 GHOSTRIDER PH. 760-473-5052 PH. 858-212-5660 E-mail, twghostrider01@yahoo.com CLIENT Owner DATE 1/10/2022 ARCHITECT Krenek Design Group ...... ...,,.,...,..,,..,,.,,.."=""="'="',,,.,..,~c-===-=-==-E-mail, Sdmosch@gmail.com AILY INSPECTION REPOR PROJECT Argonaut Manufacturing ADDRESS 1896 Rutherford Road c1rv Carlsbad, CA 92008 6520 Nancy Ridge Drive, San Diego, 92121 JOB# Ghostrider Inspection, Inc. ENGINEER Miyamoto 5550 Baltimore Drive, Ste. 100, La Mesa, CA 91942 BUILDING PERMIT/DSA/OSHPo# CBC2021-0377 PR0J.1D# Not Applicable coNTRACTOR Kyler Construction w. D. # Not Applicable INSPECTION SAMPLES QTY, MATERIAL DESCRIPTION CHECKLIST Epoxy All-thread Concrete, PSI: # Unknown/Existing Epoxy Type: # Simpson SET-3G (ESR 4057) Batch Number: # 1000182191, Exp. 06/2023 Threaded-Rod: # 5/8" Dia. (Galv.) Approved Plans Available Compressed Air Blow,Brush,Blow Bottle Brush Nylon 3/4" Dia. Edge Distance Approved Weather Sunny Bright Safety Gear: Hardhats,Glasse~ REMARKS: Inspected contractor's epoxy of post-installed hold-downs throughout project as shown on Detail 17 /S502 of approved drawings. Contractor used 5/8" Dia. (Galvanized) all-thread. Contractor drilled ¾11 Dia. X 411 deep holes. Contractor used clean, dry, compressed air & a nylon bottle brush to clean hole. Holes were filled and rods were installed. Work on project is ongoing . Work on project is ongoing. CERT/FICA TION OF COMPLIANCE: To the best of our knowledge, all of the reported worlc, unless otherwise noted, substantially complies with approved plans, specifications and applicable sections of the building codes. For this report to be valid it must have a final report, signed by the special inspector, stating "Fina/ Report of Inspection and material testing#. Without a final report this dorument Is Invalid. This report covers the locations of the work reported only and doesn't constitute engineering opinion or project control. rm• in Time out: Authorization: _...:.T.:...:Hc:E--=Da.::E:.:.P--=U~TYc..:...:S'--_______ _ Signature. __ ~-------2-='----__.. '-__ --_-_-_-_- Ian Logue I.C.C. & San Diego 1332: This Is not a government form. The Federal, State. County and Qtvseals only signify that lnsocctfons are conducted under Fedr,al. State. County and City Codes l2QB. c.s.c./. This document is not used for advertising. market/no or promotions. This document Is used Ip convey comollonce with the Codes. 01-2008. Rev. (18) 9/2015 • 1W INTERWEST A SA~ o 111 •MPANV DATE: NOV. 05, 2021 D APPLICANT D JURIS. JURISDICTION: CARLSBAD PLAN CHECK#.: CBC-2021-0377 SET: II PROJECT ADDRESS: 1896 RUTHERFORD ROAD PROJECT NAME: ARGONAUT MANUFACTURING [:g] The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at lnterwest until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: [:g] lnterwest staff did not advise the applicant that the plan check has been completed. D lnterwest staff did advise the applicant that the plan check has been completed. Person contacted: Kimberly Krenek, AIA Date contacted: (by~ ) Mail Telephone Fax In Person 0 REMARKS: By: ALI SADRE S.E., CASp lnterwest 10/29 Telephone#: 858-558-5935 Email: kimberly@krenekdesign.com Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 DATE: OCT. 15,2021 JURISDICTION: CARLSBAD PLAN CHECK#.: CBC-2021-0377 • 1W INTERWEST A $AFtbu11t COMPANY SET: I PROJECT ADDRESS: 1896 RUTHERFORD ROAD PROJECT NAME: ARGONAUT MANUFACTURING 0 APPLICANT 0 JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at lnterwest until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: D lnterwest staff did not advise the applicant that the plan check has been completed. ~ lnterwest staff did advise the applicant that the plan check has been completed. Person contacted: Kimberly Krenek, A IA Date contacted : (by: ) Mail Telephone Fax In Person 0 REMARKS: By: ALI SADRE S.E., CASp lnterwest 9/28 Telephone#: 858-558-5935 Email: kimberly@krenekdesign.com Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 CARLSBAD CBC-2021-0377 SET: I OCT. 15,2021 GENERAL PLAN CORRECTION LIST JURISDICTION: CARLSBAD PLAN CHECK#.: CBC-2021-0377 PROJECT ADDRESS: 1896 RUTHERFORD ROAD CONSTRUCTION= V-B; STORIES= TWO; HEIGHT= NO CHANGE; OCCUPANCY= B/F1/S1 SPRINKLERS= YES; AREA= 8,110 (THIS PHASE); SCOPE= T.I. DA TE PLAN RECEIVED BY ESGIL: 9/28 REVIEWED BY: ALI SADRE S.E., CASp FOREWORD (PLEASE READ): DATE REVIEW COMPLETED: OCT. 15,2021 This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code, and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, or other departments. The following items listed need clarification , modification, or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county, or city law. GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to lnterwest and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to lnterwest, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to lnterwest only will not be reviewed by the City Planning, Engineering and Fire Departments until review by lnterwest is complete. CARLSBAD CBC-2021-0377 SET: I OCT. 15,2021 2. A reminder that due to Covid-19, the City will not permit counter corrections. Please make sure all the items are satisfied; otherwise, another round of corrections will be necessary. 3. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. 4. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list?□ Yes □ No PLANS 5. Please specify the suite number on the plans. Alternatively, indicate this T.I. is on the 1st floor, etc. 6. Please call-out door #902, as per door schedule, Sheet A7.0, on the floor plans. [Sheet A2.1]. 7. Please show typical window elevations with glass thickness, type, indicating tempered glass as required, as per Sheet A2 .1, on A7 .0. 8. Please cross reference the wall types on the floor plans. I.e., on Sheet A2.1. See details 13 & 14/A 10.1. For example, it is not clear where detail 14/A 10.1 applies, since all ceiling notes on Sheet A4.1 refer to detail 13/A 10.1. 9. Roof mounted equipment must be screened and roof penetrations should be minimized (City Policy 80-6). 10. Please indicate the new roof mounted equipment versus the existing equipment to remain via a legend on Sheet A2.3. 11 . Title page indicates the Title 24 forms are on sheet E004 however the actual page is E003. STRUCTURAL 12. The City Policy requires that their special inspection form be completed and returned at back check for this project. This Form is available at the building department. 13. Please specify the plywood sheathing index, ID# with nail size and spacing on Sheet S121 . Alternatively, refer to other details on plans for this information. 14. Please add a schedule on Sheet S121 for all the equipment as called out on the platform. 15. Please show connection details and references, for the R-WT, as per page #16 of the calculations on the plans. CARLSBAD CBC-2021-0377 SET: I OCT. 15, 2021 16. Additional corrections may be necessary, once updated plans and calculations are submitted for review and approval. CURB RAMPS 17. Show the locations of the detectable warnings, with details and references on the plans, as per Sections 11B-247 & 11 B-705. The items in blue font in the accessibility list are emergency code changes, effective, 07/01/2021 . 18. Detectable warnings shall be installed in curb ramps with one or two entrance/ exit points that are 6' or 9' wide, respectively. Section 11 -B-705.1 .2.2. See Exceptions. Please show how this section is addressed on the plans as required. [Please update detail 1/A10.0, accordingly): 19. Detectable warnings are not permitted in the required turning spaces, clear floor spaces, landings for doors, pedestrian ramps, access aisles to accessible parking, drop off/ loading zones & stairs. Sections 11 B-304.2, 11 B-305.2, 11 B-404.2.4.4, 11 B-405.7, 11 B- 502.4, 11 B-503.4, 11 B-504.4, and 11 B-705.1.2.2, respectively. CARLSBAD CBC-2021-0377 SET: I OCT. 15,2021 Truncated Domes Requires outside of landing and show details and notes, 11 8-24 7 and 118-705 Figure 118-404.2.4.1 (a) -3'-0" MIN Access Aisle, 118-502, were occurs, must maintain parking stall length 20. Circulation paths shall be minimum 4" above adjoining vehicular traffic areas including parking, driveways, drive aisles, vehicle charging spaces, etc. Section 118-250. [Please identify the circulation path on the plans and show compliance with the following item as required]: See Exceptions as well: L I Circulation Path ◄Vehicular Traffic ► • 21 . The P/M/E design is approved. • • • • MISCELLANEOUS • • • 22. The jurisdiction has contracted with lnterwest, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact ALI SADRE S.E., CASp at lnterwest. Thank you. END OF DOCUMENT CARLSBAD CBC-2021-0377 SET I OCT. 15,2021 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: CARLSBAD PREPARED BY: ALI SADRE S.E., CASp PLAN CHECK#.: CBC-2021-0377 DATE: OCT. 15, 2021 BUILDING ADDRESS: 1896 RUTHERFORD ROAD BUILDING OCCUPANCY: B/Fl/Sl; V-B/SPR. BULDING AREA PORTION (Sq.Fl} T.L 8110 Air Con:lilioring Fire Sprinklers TOTAL VALUE Jurisdiction Code CB I 1997 UBC Building Ptrmlt Fee iJ bf).1.,:·;.1:: I 1997 UBC Plan Check F .. I ~I~--;,,: Valuation ~ By Ordinance Type ofReiAew: r.i Complete Review r Repettiye Fee ~ i .::!.l Re peats Comments: r Other r Howly EaGilFee ~ Reg. VALUE Mod. r Structural Only 1------,]Hr. @ • ($} 377,196 J , $1,048.421 Sheet 1 of 1 • 3 - Structural Calculations for Argonaut Phase 3A Tl Carlsbad, CA September 2021 c, 2020 M1yamc10 lnt•m•~onal. Inc., All nghl1 , .... ,...,d Th• doe um..,\ or any pan !li•raot m""l no\ CBC2021-0377 1896 RUTHERFORD RD ARGONAUT MANUFACTURING 8,110 SF TI 2121203000 9/27/2021 CBC2021-0377 ( (_ mlyamoto Project:~p.....,_,.A_6c...;...-t>f'rSU---'--'{.__~_~ _____ 7 ,.._ Sheet No:~ • Project No: "'t.,-\ \ o 1,,-;-L) ✓Cale. By: f Date:~= s ~~ ·. c.~ I \..4 .5, Ip 5 ..:s /> /I 0'1.::f h tL Y1 ~ p ~ ,rflll~"' \ " \ , A,_; c.._ ~, U )'-" ~ V Ff~ "4• ' -& -~ -I,. 1'° -,. .,. \ ~ '-'( ls:. t-<?-:;, '. ~{~· f" vi .. u. I) "'l., 5 0 ~,'::,~ "'L.::> -t,:>'i:"-6\., ';il.A ~""'r_. ·• ~S t~f Ll~-1$" r~~ ( (_ m1yamoto Project: __ '17....:___f> _____ SheetNo: ')..., • Project No: ------Cale. By:_ Date: ~(;,-= rz.; r'"'lf (' '-\~---~ 5 Y\-~'--" 1Et.. 1r 5'\)l9 \J -:: S A• ,,, -(I. \ ,~ '--C>. \ ·t., ~ (l' ~,-: ,1 i(iSx,g .1lj'i-,:,z~t.') ~ ,4 (~ r tS 1. -. ., \ t. \ ~ )( i \ ~ 1..,. , L?c ~ ') -=-\ s; e-f 'J , ·. \J~ .. '-o~x 14 -1 f z..-:. f~S.., \J'l.,~ ->.Jb -: 1 4-► I~ ~-.to \4., "~ ~-.J_, ~ 7~ ... '\..'-~ ~ \ ~ @ fi,.i, 'g -~ ?b :'-'" t. 'h,u... ,c ?;;;t, pvr @ }-\~~'\ H_,v9.,,._...1> ,~"7'4~- t ""' 0 " \ 0 -/,;I'(,,>~ 1 '-1 p...f .,.~ S1> <~ I? V 'I. L < c., d., • I "!. ' -) = I -?J.-z.. ·-I i.; "-"?, >" ( ~ ,111 d ...-.A_ l • ~ )( . .;. )Q \ 1.. 1 ;.. a ~ Y\:1 ·C v. ·· o , -t --I 7., ~ •• , f., ., . ~ .... , '-( ' ~ \ '_,_ , ... ~ T "• '\ -\ ,1 / 5 I :-\ n~ ~ ~~) e .../ l ·. e,, ~ ~ , l,. .. \ 1--~ 1-i wt ~--1,r,'{)'\~" Jt-..lt }o''t»~+-1 p..,llA : .v1-. '-(.-6,., •~/~ 'J 1J1 )J c,n,vi ~ \) ~ \1\.0 e ~~t."', ~s >, 'i ) r,~ C ( (_ m1yamoto. ~,... Project:--=---:---------Sheet No:~!?"---- Project No: ___,'1,.,...,.\ ....... \-'--.;o----''2.w..,,S)~--Cale. By: __ Date: ~ .. p~~,: $~..s.D Uc:.J<cL; )2 Of-t o \) oi 9-0v\ c~ (.) T -= \ r .. , ,c,~ 71.., / f:,o;( 7 o H' 7 ~( /h7:> ';~~ ?~,< £4 l-f 'fl.A~ ...J o If.\ o, ~ f--/.. -1\ .J ·o '5 )'l,7 ; 4)>) 1 ~ 4Y H GJ:; Cl 4'7.,..'61 • Sb Ji e r-)1.1-<~o,~1 ~,o. '/\.~o....-~::: ,~ ~ ?q'°--~ ~-¥ 1- C~J<k:-f c~'--:) ~~4\•~t-r. ·. S1!, ~ o ,7 f. ~ ,, 'L ~ ~ .. '°. !>-.:, ,1~~ l .' ~ i) x ,1--,.. ! .. _5 (le :~.~ ~-:1,,0 ~~ ~'tt~L,, Q \ (l,~O ,o \ (1. \ff /JJ \ ~ O , t 1 ~ ( A '0 ) ~"-~ ~...("r ~ fp -: o/;S1~ -. (1. 1,,-; _(\. .. , 1, 0 ~c..~( ,-\c mIvamo1 Date j-4/2021 Overturning of Equipment Design Parameters ap = 1.0 component ampflication factor n0 per ASCE 7-16 1.00 Sos = 0.78 spectral acceleration, short period Strength Design: .90 +1 .0E Ip = 1.00 importance factor Allow. Stress Design: .90 + 1.0E/1.4 RP = 2.5 Component response mod. factor SD or ASD? = Allow. Stress Design Slab on grade? No z = 2 ft. (ht. in structure of point of attachment), z=O @ grade h = 2 ft. (avg. roof ht.) z/h = 1.0 Fp = .4*ap*S05.Wp*(1+2*z/h)/(Rpllp), (13.3-1) Fp(max) = 1.6*S05*Ip*Wp, (13.3-2) Fp(min) = 0.3*S05*Ip*Wp, (13.3-3) Fv = .14*Sds*Wp, (12.4.2.3) OTM = Fp*unit height/2 Floor/Slab/Footing Loads RM= (.9-Fv)*Wt*unit width/2 Unit Size, feet Curb weight, width length height ht, in. lbs RDH1-2 3.25 13.0 5.8 14 1,800 RDH3 3.0 2.5 5.3 14.0 747 RAHU1 5.25 9.7 4.8 14 1,520 RAHU2 3.6 6.8 4.2 14.0 950 RAHUS 3.6 6.8 3.8 14.0 1,275 RCU2 2.5 4.0 5.6 14.0 570 Anchorage Loads Increased as Required for Q0 Fp Fp(max) Fp(min) Fv Fp 483 200 408 255 342 153 - - Single Anchor Loading with n0 No. Anchors OTM xilo Vx ilo Uplift T max Unit T101 V,01 ft-lbs lbs lbs lbs RDH1-2 3 6 1,963 483 No OT - RDH3 2 4 764 200 No OT - RAHU1 3 6 1,454 408 No OT - RAHU2 2 4 832 255 No OT - RAHU5 2 4 1,048 342 No OT - RCU2 2 4 606 153 17 9 ---- ---- = = = = Fv 197 82 166 104 140 62 - - v,.,ax lbs 80 50 68 64 85 38 - - 2019 CBC Overturning of Equipment Anc asce ch 13.xlsx 0.27 WP 0.89 WP 0.17 WP 0.11 WP OTM RM Uplift, lb! ft-lbs ft-lbs 1,963 2,312 No uplift 764 886 No uplif1 1,454 3,154 No uplift 832 1,352 No uplif1 1,048 1,814 No uplift 606 563 17 -- -- User Anchorage Notes mIvamo1 Overturning of Equipment Design Parameters ap = 1.0 component ampftication factor Sos = 0.78 spectral acceleration, short period Ip = 1.00 importance factor Rp = 2.5 Component response mod. factor Slab on grade? Yes z = O ft. (ht. in structure of point of attachment), z=O @ grade h = 2 ft. (avg. roof ht.) z/h = 0.0 Fp = .4*ap*S05-Wp*(1+2*z/h)/(Rp/lp), (13.3-1) Fp(max) = 1.6*S05*Ip*Wp, (1 3.3-2) Fp(min) = 0.3*S05*1p*Wp, (13.3-3) Fv = .2*SDS*Wp, (12.4.2.3) OTM = Fp*unit height/2 Floor/Slab/Footing Loads RM = (.9-Fv)*Wt*unit width/2 Unit Size, feet Curb weight, width lenath heiaht ht, in. lbs R-AC-01 3.80 7.3 6.3 4 6,450 R-AD-01 3.00 3.0 6.5 4 1,100 R-Wt-01 2.70 2.7 10.3 0 1,135 Anchorage Loads Increased as Required for n0 > Date 9/14/2021 'lo per ASCE 7-16 2.00 Strength Design: .90 +1 .0E Allow. Stress Design: .90 + 1.0E/1.4 SD or ASD? = Fp = Fp(max) = Fp(min) = Fv = Fp Fv 1,513 1,009 258 172 266 178 -- -- -- -- -- Strength Design 0.13 Wp 1.25 WP 0.23 Wp 0.16 WP OTM RM ft-lbs ft-lbs 5,271 9,113 925 1,227 1,371 1,139 -- -- -- -- -- Uplift, lbs No uplift No upllfl 86 Single Anchor Loading with n0 No. Anchors OTM x !lo vxno Uplift Tmax VMax User Anchorage Notes Unit 1101 V101 ft-lbs lbs lbs lbs lbs R-AC-01 2 4 10,542 3,026 376 188 757 R-AD-01 2 4 1,849 516 207 104 129 R-Wt-01 1 2 2,743 533 594 594 266 ----- ----- ----- ----- ----- 2019 CBC Overturning of Equipment Anc asce ch 13 (Generator).xlsx mIvamo1 b Date 9/14/2021 LRFD Hilti KB-TZ Seismic Anchorage Values 3000 psi-Cracked Concrete Design Normal Weight Concrete lambda=1.0 Lightweight Concrete lambda=0.8 Normal Weight Concrete lambda=1.0 Anchor Type Min Cone (in) Edge Dist (in) T max (lbs) Vmax (lbs) 3/8' KB-TZ w/ 2' embed 4 in 4.00 in 12121bs 1466 1bs \' KB-TZ w/ 2" embed 4in 5.50 in 12841bs 1844 lbs 1/2" KB-TZ w/ 3.25" embed 6 in 7.50 in 26251bs 35721bs 5/8' KB-TZ w/ 4' embed 6in 8.75 in 3631 lbs 4940 lbs 3// KB-TZ w/ 4.75" embed Sin 9.00 in 46991bs 7934 1bs Note 1: For KB-TZ in concrete filled metal deck min cone thickness is 3.25' -Values do not change for 2' Embed Unit Anchor Type T V T% V% T%1~~1+V%1"'~1 R-AC-01 1/2" KB-TZ w/ 2" embed 1881bs 757 1bs 15% 41% 0.27 R-AD-01 1 /2" KB-TZ w/ 2" embed 1041bs 1291bs 8% 7% 0.03 R-Wt-01 1/2" KB-TZ w/ 2" embed 5941bs 2661bs 46% 14% 0.32 ----- ----- ----- ----- ----- 2019 CBC Overturning of Equipment Anc asce ch 13 {Generator).xlsx Joist and Beam Capacities 2 x Joists Av= 180 psi Repetitive Use Increase = 1.15 Fb= 900 psi Nominal Actual Section Moment Width Depth Width Dept~ Cf Area Modulus of Inertia 2 4 1.5 3.5 1.5 5.3 3.1 5.4 2 6 1.5 5.5 1.3 8.3 7.6 21 2 8 1.5 7.25 1.2 10.9 13.1 48 2 10 1.5 9.25 1.1 13.9 21.4 99 2 12 1.5 11.3 1.0 16.9 31.6 178 2 14 1.5 13.3 0.9 19.9 43.9 291 4 x Beams Av= 180 psi Fb = 1000 psi Nominal Actual Cf Section Moment Width Deptt Width Deptt Area Modulus of Inertia 4 4 3.5 3.5 1.5 12.3 7.1 12.5 4 6 3.5 5.5 1.3 19.3 17.6 49 4 8 3.5 7.25 1.3 25.4 30.7 111 4 10 3.5 9.25 1.2 32.4 49.9 231 4 12 3.5 11.3 1.1 39.4 73.8 415 4 14 3.5 13.3 1.0 46.4 102.4 678 4 16 3.5 15.3 1.0 53.4 135.7 1034 6 x Beams Av= 170 psi Fb = 1350 psi Nominal Actual Cf Section Moment Width Depth Width Deptt Area Modulus of Inertia 6 6 5.5 5.5 1.0 30.3 27.7 76.3 6 8 5.5 7.5 1.0 41 .3 51.6 193 6 10 5.5 9.5 1.0 52.3 82.7 393 6 12 5.5 11 .5 1.0 63.3 121.2 697 6 14 5.5 13.5 0.98 74.3 167.1 1128 6 16 5.5 15.5 1.0 85.3 220.2 1707 Project 1,f.,.,,._ Eng~ \ Roof Load Increase= Shear Moment Vr,floor Mr.floor 630 396 990 848 1,305 1,360 1,665 2,029 2,025 2,729 2,385 3,407 Shear Moment Vr,floor Mr,floor 1,470 893 2,310 . ~ 1,912 j 3,045 3,322 3,885 4,991 4,725 6,768 5,565 8,534 6,405 11,305 Shear Moment Vr,floor Mr.floor 3,630 3,120 4,950 5,801 6,270 9,307 7,590 13,638 8,910 18,419 9,662 24,033 Shear Vr,roof 788 1,238 1,631 2,081 2,531 2,981 Shear Vr,roof 1,838 2,888 3,806 4,856 5,906 6,956 8,006 Shear Vr,roof 4,285 5,844 7,402 8,960 10,519 12,077 Sheet :f Ml No. Date 9/14/2021 Wind Load Increase 1.6 1.25 Wind Wind Moment Shear Moment Mr.roof Vr,roof Mr,roof 495 1,008 634 1,060 1,584 1,357 1,700 2,088 2,176 2,537 2,664 3,247 3,411 3,240 4,366 4,259 3,816 5,451 Wind Wind Moment Shear Moment Mr.roof Vr,roof Mr.roof 1,117 2,352 1,429 r 2,390 3,696 3,059 4,152 4,872 5,315 6,239 6,216 7,986 8,459 7,560 10,828 10,668 8,904 13,655 14,131 10,248 18,088 Wind Wind Moment Shear Moment Mr,roof Vr,roof Mr.roof 3,899 5,485 4,991 7,251 7,480 9,281 11,634 9,475 14,891 17,048 11,469 21,821 23,023 13,464 29,470 30,041 15,459 38,452 ·--.~ w· ~ ,. I .. " IIJ1D 41i \!Jib ~ ~ ~ i:i.:i """'4,,,.. .. -Ii "" rlW:Y 11ft, (:Joa~ L (WfCl1D, DOlil ll:UllO'll /Ill ruNE VU IE 11.mo TD 111101 #1'1.E!!IJII. -.&.I 1IllSA. 1111 11([1 /Ill NIil 111111[ IISTIUlli Ill l)l[MTJlj ~- t IJMICS) ,a: l'IIPIIIIJ V1111 llllftll NI NIil UtllE -· l IAJlS lll1DW[ Slll:fD, .osDII E II IEIIJ A Ill. IIIIClllS E IJIIIIIE -«TO WLt 1111.PPINiaNlffllllll' l 1111 EllCT1SIL 1111111 IIIIIIICM. l£Amlll.l IS II[ llll'UIIIIIJTI IF DllOS IIUlS P1D -HI\\'. Ell lNE '11111 lllfl!ll nm ICUE IISAlSIJII.I 11111 W IIDllMI IV flCIJIIII - !. smDIJIIJ IS TD IE nu. PDICIII -(I' smDI sm IS l'IIMIEI II llJfllRI). L l!Sllll IS IIIT IElllO Ftl ll'OI llllr Q.D 111111K ... 7. IIJtl 10 SIITDI Dia It II[ 1£ CIIIC m FIi ~ 1111 ID.EDll TD DJIIKA. NIU 1l[l[ llllallllll 1111 INCi II[ UEIIJII IF II[ lllllD IU'IDI, IT IS II[ ~ IEll'OllllllTf TD I\M II[ UfAIJll 11 nll -Ullli M &al01l 1(1 flEI II£ Ill lJ110 Ul:II. !lll1 APPRDXll'A TE lt'T. = 1800 LBS. jR-DH-01, R-DH-02I m D I "" I ..... llV • .. INtiJYATIV£ CIJlSTRIJCTI□N SERVICES .,_.., II GENERAL ARRANGEMENT HCD-2250-DGA-SMFBS r.,..... r -1 Wl;:atte, ec:r ... • ,. UNIT TAG1 I DH-3 .... 21852370-01 ~ ~ lt.....w "W"1U( w,i 000 ~ t ~ PROCESS COMPOHENTS· 1. NIA INLET. SUPPl V(PROCESS, RETURN) 2. ALTER BANK{FK..TER. HC[).IOQ. MERV I) 3. 0EHUMIOtFfER(60CI. ~. MINI BYPASS. TIGEL, All) 4 FAN(FAHHC~il60t'l07•3SENOTHRR·l3'50FtPM100'1t) 5. AIR OUTLET. SUPPLY(HCO-«IO) S1·1-&edion S2 • Pre-Filler S3 • Dol1umidifler 54 • Process fan S5 • Process ouUel NOTES: 0 Sys18m Is not doslgned lot open root cur1> rmuntfng -'---■ weioht • 7.t7 I> :!! R1 • Inlet section R2 • Reac1ivation fltte< R3 • Dehumidifier R4 • Reactivation fan RS -Reac:IMltian ouUel ATl()tl <EATER AIRROW GAUGES INSPECTIOtl -- IR-DH-031 0 --ee Systemneme 11 0 ELECTRICAL CONTROlLEA MAIN POWER CONNECTK>N DESICCANT WHEEL ACCESS REACTTVATtON - Argonaut Formulations Toiefanc»I, W nol ~. acconllng ID i CRFTtCAl. ACCESS AREA JI W. HIGH BASICPW< NOTTO SCALE 0 RECOMMENDED ACCESS AREA \I~~}~ 15 Z5 HCD-600-EA-SFB 160-010266-001 Preliminary sketch e Munters l~eier Dahlbeck ~No I G271638-1 ~ -~-i,::; tf,, D ,- -;~ ;~ ::~ =~ ~~ ~ I ~ I: c( I I: c( u, z ,-0 ~ in z I w ~ :I: ~I! --1 --.!jij ;;i ·las= :x: ·;;;=:1~ ::;c -i~ a:: I!~ --. J I: 0 c( :ii I .... I: u, X .. a: ~ i§ t l) !:::-=-• Ir'" ~¥~ Op,._ ~ ! I') :::i ~ ij~ "! i ==i s~ ! h lg I -ll ~~ E • 516 71 2308 03 Speclflcatlona aubject to change without notlca. n • i ii; --!E i§ ~~ I! t ~~ ;;; :::! .. ii CD -... 0 0 .,, ;! 0 .,, ~ ~ ~ ~ .... ....... "'::w: 0:::, ....... .... _ ~ .. ..,..., ~. "' 0 .,, "' "' .. ii R i )0' 21 IR-AHU-02, R-AHU-03 , R-AHU-041 RO CABINET STANDARD VE RTICAL ,__, 1 -6 TON CLEARANCES LOCATION • UNIT SIZE• 1 -6 TON OUTSIDE AIR 36* IBACKI HXC 36 (FRONT\ LEFT SIDE 24 RIGHT SIDE 48 TOP UNOBSTRUCTED DETAIL A -/ ...... DETAIL B fRONT VIEW POWER SWITCH FLUE OUTLET (CAS HEAT ONLY) COMBUSTION AIR INU:TS (GAS HEAT ONLY) -~::~!='~ OUTSIDC ~ RM. R0-00009 REV:E 04/13/16 MS NOTE: ALL OIIIENSIONS ARE IN INCHES *CLEARANCE IS MEASURED FROM THE END OF THE OUTSIDE AIR RAIN HOOD I 36 ea 7 COIL LEFT SIDE VIEW SUPPLY BLOWER ACCESS 0 ~ --1 r~ ,5i ~--J<l2 _j i INCH MP'T STAINLESS CONDENSATE CONNEcnON. ••p-• TRN' FURNISHED BY MIINUFACTUR(R FOR DRAIN CONNEcnON. TOP \IIEW 9 RIGHT SIDE VIEW -------82~ ______ _.. __ ,7 0 11 SUPPLY -.· ---· 7!8'i-t ------1 -------82--------l oursu MSC RM.. ,, SEE. DETAIL ··e·· IR-AHU-051 RN SERIES A-CABINET STANDARD -6-10 TON CLEARANCES LOCATION • UNIT SIZE· 6-10TON OUTSIDE AIR 36 (BACK) CONTROLS SIDE 48 CFRONTI LEFT SIDE 6 RIGHT SIDE 48 TOP UNOBSTRUCTED NOTE: THE RNA UNIT IS NOT COMPATIBLE WITH PREVIOUS GENERATIONS OF MON CURBS. AN ADAPTER CURB IS AVAILABLE IN ECAT. I I \ DETAIL C 79 COPIDENSER l'LUE OUTLET (GAS HEAT OPILY) co ... BUSTION ...,R INLETS (GAS HEAT ONLY) 44 FRONT VIEW ( 4) LIFTING LUG CON111C1l,.l#G~ - RNA-00011 NEW 09/14/09 JRL NOTE: ALL DIMENSIONS ARE IN INCHES / \ ,,,,. ------------~ FOfl°"(O UP ' ..... / •I\ ,r I \ HIGH VO\.T ~~ I I ENTRY \ () LOW 1/0LT ,f ~~ RAISE ... INI ... U... fFoR THE GAS ENTRY \ RETURN NR AND ELEC ENTRY OPEPIINCS. ' ·-; / ' ~ / "----..... --DETAIL A DETAIL B SEE DETAIL "C" SEE DETAIL ''A'' I •on 44 ~ u -------82~ ------- I TOP VIEW SEE DET"'L ··e·· 24~ _ _,__ __ 27 --'-- 82~ RIGHT SIDE VIEW SUPPLY BLOWER C~)~ :· - ~~ I ·• • ff ...... I I OMPIRESSDR ...ccq;s : RETURN •RETURN OPENINC IF UNIT SELECTED INCLUDES RETURN "'R OUTSIDE "'R 22~ ~~~N~Zf~a.W DAMPERS 'MANUAL 0/A OPTION INCLUDES ADJUSTABLE PANEL I" °"PT STAINLESS CONOCNSATl: CONNECTION. "P" TR.AP FURNISHED BY "'ANUFACTURER FOR DRAIN CONNECTION. ' - I• LS L6 NM ii w t Airllow □ :c El 00 ! ~ [Pi9in9£n11y I knockowt r~ I'.:! ~ ..J • .,._, . 4 L8 ,~ t::i ... .LG Life's Good Tag No.: ________ ..1..\ _.!)~- Date: PO No.: ____________ _ IR-CU-0 1, R-CU-02I <}-- Airflow 3 t 51 L10 w H D L1 L2 L3 l4 L5 l 6 L7 LS L9 48-13/16" 66-17 /32" 29-29/32" 6-5/16" 3-3/4" 5-29/32" 5-13/32" 2-25/32" 24-9/32" 2-25/32" 4-1/32" 6-112" L7 1-o-i--o ~1-3/1' Dlamttlf wiring knockout 7/IS'lliomoll<LNkTootHole Left Side Vew M5 M6 (Pitch ot foundation bolt holes) Bottom Mounting Holes LJ l4 • 1.25132• Oiomttlf front View wirw,g knockout Two (2) 7/PJ' Diameter w,e Routing Holes (Bottom) 19/32" Diameter hole M1 M2 M3 M4 M5 M6 M7 M8 M9 M10 M11 M12 M13 M14 M15 M16 28-25/32" 5/8" 3-15/16" 40-15/16" 11-15/16" 11 -1/16" 10-1/2" 8-7/16" 8-1/8" 6-1/16" 4-15/16" 7 -1/2" 4-13/16" 4-5/16" 3-5/8" 3' l10 5-9/16" l11 8-5/8" L12 6-7/1~ l13 9-15/16" l14 3-5/8" Center of Gravity X 23-7 /32" y 15-5/8" z 25-9/16" All dimensions have a tolerance of :t 0.25 in. [Unit: inch] ~ = Center of Gravity For continual product development, LG reserves the r;ght to change spec,flcations without notice. SB_MuftiV_S_ODU_ARUM096DTES_2021_05_26_155640 Cl LG Electronics U.S.A .• Inc., Englewood Chits, NJ. All rights reserved. "LG Life"s Good" Is a registered trademark of LG Corp. /www.lghvac.com Page 2 of 3 395 Inch I 1000 mm) '\ I Zuluft 114)1iy or I , ~ ·p __,,, ,s31ncn ~ Ctt50nml c rJ&i~i !! fl -~ ::la: /' , H <Do ..-N """ I l f }ct8~11 2d) -i:: Zuluft .,g:e vi E~~ •rar AIJluft l!Xflaust t-c ~too~ - I - T 2i <'jg "'"' Wt t""""51 D ·::::::,, IR-AC-01 ; I i i ~ :: Zuluft .. >! I 1-----1 SlWlr air O -~ u•f-. =t-·-71111med --~ _2_ n~t 2~~! _It ·1 ~ I I J_L~-j • j•1 r.1 621nch E4391nch -439tnch --'~ti Kabtle~fdltllNJ coble entry point ' 2xH£4 I 160 rrml I lt20 rrml [ lt20 rm,J [ ~J~~l lschallgedarrml / Silenced [ ~,8 ~J I ~~7,i ~l ls-scholtg.-V,,t / supers,lenced I :.icr:~orow; --10~-------:::a, ~-251tnch rmn cJ~~J l-Pi __________ Otlktnabstand '2 I ; § distaru to rtling ~~ ~71r-----7 f L_,., r I I ~ I lhnbJflauslritl ,_,,,.~ er cutlet RMSCh/Rong, [65176.t IJH 263l ~] ,oO .;"' ... ~ !] L' al ,11.1:::::, llll 8efts19119 cul dem 8cden 111Clrt erfon!er\Ich filing on i,cu,d oct necessary I liNichl 5ci1ol.l / ~chcll wight ~!med I _.;tenced \ 4"12S rli~1 \ -~ ~(l!IOmml ~ (920nm) t (640mm) f; E ._scholl I .c E ~ E -1 ifo° ,:g; supers,tenced min. 31.5 Inch 1800 rrml 21 lie slat Belas~ Uege,, 111ter don II. val w SSf9!1' 'tlerlen I Th• slatK loads bttcw thr permisslbte wluts acconlinQ to val 1 Sdurtl I ~It • saenced / ~ienced ~ E :g n .3 Inch 29.9 Inch -2 ..,_ 0 r ~4o mml I 760 mml "'= ,-9~ t 28.1 Inch 7 r scholt I silenced [ 720 rrml -i, !!iii I ~] ~~11 ~ ~] ~ 1 ! i jj 2] ;~ ~i ·J ____ _ ~ 1fgN'~1 LJ 'w'artu,gsabstond IIGi•tenanc, """""' 8e<lirnseltr / ~1111!1 ~dr ,rrw,. 1 Jt.51nch J-------------------- 800 rrml ledmchr Andenr,grn -ten Siche<Milsallslond ncdl Vil OtlO Tel 72'J Ill "'1tls resrmd for technical chrrng<s safetr clecrence act to WE 0IOO port 72' -;;LJ fi n~ ii,, ..,_ ,, I /doer ~ I I kQ 1! 11 ~] ~ ..-: I lbs S061A 265412'l34 5851/6468 S076 A 2804/3084 6182/6799 S0101A 2'Jl413214 646817086 50126 A JOWJ326 6715f7lll 21 N/cm' 57,5/63.5 60,7166.B 63.5/69,6 66.omo J ll'llmllf1illtn0! worm ar a.mc111t 41 erlorderlichrr frr,er ~tnilt r,q.rnd frre !Mf [TCSS•sec11011 51 erlon!erlic!ie Veotictort,;sf1111J ZII' 8et~Of11111J r~ ,enfiator power for ""'~alien of 10t<han.~lll rcon, 61 erfordertichr Zuluftofftuil tlti Erm ,an Jatousien 11.G. ca 20.. i,ukrl req.,r'td ... , ar opening twtlll 1111tllllat 011 of slllft,rs ond smlar QWOl 20.. Mrt ~~ 21 3l J 41 41 51 51 61 psi m'II, cfm •. ... 11 11'/h elm m' 83,4/'l\7 V.500 9712 0,92 10 IlOOO 19423 2.00 M.V'l6.9 V.500 9712 0.,2 10 llOOO 1'1423 2.00 91,7/100,9 V.500 9712 0,92 10 3:IOOO 1'1423 2.00 95,7/104,4 V.500 9712 0,92 10 llOOO t'J423 2.00 I I 1=-l1 1:.. 61 snit 22 22 22 22 .... _......,.._.___,.___,. __ .. t;,--·--·... ·-·---···-------------·•-----··--~---·-·------~-·--------•--..-. i...,•-1 = I-• ,.,...... ICIDCL I/ » HT CONN. \IEIGHT HU)■ 26 1/l!' 26 1/i!" 59 V4' 314' l90t HU)7t 27 1/2' 30• 52 1'116' 3/4' 270I HU) tit 27 Vi!" 30' 64 3/16' l' JOOI HU)1N 31 Vi!" 33• ~ 1/8' t• 41511 IR-AD-01I HLD-40' 40' 61 3/16' l V2' 54(11 HU)JN 40 3/4' .,. 73 11•• 1 1/2' 5901 HLDHt 44• 42' 64' I 1/2' 73511 ~ .... ~""--79~7/r -'"r"" ~ HU)-52' 46' 75 112' 2· l600I HLDIN 52• 46' 115 3/4' 2 112· 2000I ~ ~1 C) C) ]ll Li l ~ ~ ----,,, -s~ .. s~ 0 I;; i;; u ---- ',/ TOUIWICES II.II.I -a~------■-D MUIT ...... --ALL DDCHSJOrCS, t_l/16' -------..... ---1■1-.... --" Nr I< I IIIYIIIGIII IZOIEIIIEYIEC:O NOi IIHClll'TIGII I DAn IIIEYIY I I 00 IXXXUIIIB.EAIED 11.1-22-191 XXX ., ~ I) [ ~ T - A I' D ........ ,..caw ... •na ......... ,. ... ....,.,. ....... ~.#ff ~-Mll"f ca MA ..,..,..,."9 ....... ,_ ....... --- --1-.. 1 .... ----1 IJAS 111/20/19 II HT •-L_J ~ 'I _ _. $E3 J@!!~~ -■ IIT ICM.I -- -Hl!AlLQI HU). 'IO HU)- cl--,-· HLIMHN --,------,-i'o 1 Ofl At" "'- I I ----,---- ' I I I I I I I ~ I I i \ i f ----1--- [9UL IN llDlflON TIQN-1MWl1000I!) THIIOM,WNG&~TIONSMl~OI' IPVGNC>IMYNOTM: o:,,,l(D, 111£1'f100UCfD. 0111 UlfO.,. '#0.l Ol'l P'MT AS A.,_,.. ,(lllt CHICN ...,,...AC'f\.Ni0flUU::'#lfflOIT.....,_~RIOWW'o/Q IR-WT-01, R-DT-01! 1111 .. ~ " ,;,, 1 1 f -.Af 'r Y 'f ,✓ ./ i ~i i i i i i : l t ... I I I l '~-• 1 • L I ~ 1 I 'r ~····"' I n-.....,___ • 11 r@ . _@ . I: ----------~-•• __ •__ I . ' r--------~iP=. ~~ •. ,· ·, -------l . '. r::i ~ _ _.___... ! ~. -----. ;.; r. ~· ::: ~ •• F--J ~ ~[ ! !~==-=§~~ • 1 " r ,=,,, -, , r ~ \ -' : ' •el.----~-_ , ~ ~ r · l) -1. ____ ---:-... =-I .._... . , --0 -0 ij~=~=~-:~= :,__; .~ . ~ ii ~ ~ ~ ~r,,-1 J -·~: . ~ } ~----1 11 .f 7 f ::.w~ . I ~ ------,@ -.. -~ ·-~!'Fb ie, .\ ---·-~~ . ,t ----=-""'"-- . --:· ,.. . , , , I , , , t t . i:::~ ~ ~ 0 t = • . I -+-+---+++--+-l--+---4-j=:'~,,....,...~ ~ : _ _ _ -:., . . ~ ~,_ l . ·r =-i : .· \. . f8r-,....._ -1 ... ~ --__ _J ,.:, • •'c_. . / _:.... 1--: • ~ ~~ t __ • · · · · A [ -[ ,•. l r [ ~ 1--+---1--+--1-++--=o1---+---1f---+--l-+---1 f I ----i t'.4--,,.,,----~-~ } , r r ~ . : l! ~ ~ ~-. ~ .., I · __ ; ~ . _ _ T . --~ __ _ ___ r✓-: ij ,~~-----= •--•w-. I ! 1~ • • • ~ 1 ,__._.........._...._._, ____J I ,,_I ? --~ l . . -~_/ ,..!... ·-~v-•..._ I I , ... , · ~-. i i . . I ,.... .. ... 1--•. .:.. •◄• • I I I ........ -.-•""" ., _ .. ,,, ,l )._ A A ..... :.J )_ 0 DrK,N, IIQCif' Pll!eflMM 11,•--.c., 181'\."1-... f9 ...... -~ D -· .. •··-~--·•·u -•"""" D -•:tll,·•"-~ .... -···---er•• CJ -•r.,._COW"N,0,11.,... -•r•, .... a-, ... -~T-.e -..,...,,.T T~~(TQ ,,......,...,. """"-L.0.-o .,., ---... .,., ----.... --... .,.. --... .,.,. --... ,.. --, .. .,., --, .. .... --,_ .,.. ---.,.., ------------• fo,' ..... ~/U..\.o,,,o .. ~.,.,.. ......... --- • ~'AolC,trt.\.o,t,O.,.,_~ ........... ~ . .. -.c.• .......... t.,o,,,p-,. • ..,,.~-~ • 'l'C,"_....,\.o,t,O~A'fa,ta:.,,.,.._,,,NU,..,,_. ~noo.,...,.,.._-'-""411M"-,OOOID _...,c,w,o~ • ta:CIC"' ..... -....a.~------~ l _....._....,,. ..... , ...... .._o,1__,.M, e. -1001.a-~-~•T......,.._.-i.f ~-_,__.....,..,_..,.,.~ NJ9~,,,,-........ ,_,....,"'09ff ~--'!IPMO ... .-~ .... ~ ..... .-... 10 -...11Mt,-tMll"6.~•_,.,..,.._..-w_ .. ~· ... -~ .... ~ :-~\ r--~ - ,. IC. ,, / 126\__ =-~ ~"°"'° .JOt!IT 61-~ -~ .O~T .,,,.."""""""" .,... __ """'4"""" ... --.. -.. , .. .,.,. __ -... ---·---&-4 --·------·--... ....4 .... -.. , --·-- ..,.,..HCZtDt ~,.: l ~•~~ ....... -~ ~~, ,: -::=========- ,0 ... 3 I :1: ~ ~ ! < \) ~ ~ ~ . , ... ' p ; :~;. ~_:.::-:;--.at-: ... 1 L \J"" G ~ , ~ .. =-:..:..":~~-~ ........ ... "I ... ~·-Ar-• ..... Jlillllllt'-...U..• =-,. ................ ,""'" .... ~ ._ .-.u.---.-...~.-...,__,_o, .. v-. • ~-.... ._...G,IIM...., .... ~ -,.....-,. j, ---•IIC.e \ ,.,_~ .....,,.,..J IO\__nn.a&.~.,, ,.._ ._ ....... ll'OWI' EB ROOF FRAMIN6 PLAN ...... 1-·.,... :3 _;;.:- S-4 5/5/2021 U.S. Seismic Design Maps a OSHPD,'b -<1 1896 Rutherford Rd, Carlsbad, CA 92008, USA Latitude, Longitude: 33.1350124, -117.2831343 Carlsbad Kickboxing ft Club Boxing Martial... T 7-Elevenf An~i'ie Fitness 9 VCA California m t AveterinafY Specialists T ~C! ~atada;, -'t ~ "~ Date Design Code Reference Document Risk Cat.gory SHeClass Type Value Ss 0.978 s, 0.357 SMs 1.173 SM1 null -See Sectlon 11.4.8 - Sos 0.782 ~ S01 null -See ion 11.4.8 Type Value soc nun -See Section 11.4.8 Fa 1.2 Fv null-See Section 11 .4.8 PGA 0.427 FpGA 1.2 PG~ 0.512 TL 8 SsRT 0.978 S1UH 1.086 SsO 1.5 S1RT 0.357 S1UH 0.392 S1D 0.6 PGAd 0.5 CRs 0.901 CR1 0.911 Residen~lnn '° by Marriott San Diego... e --✓ .. .s-, p,.~ ·~ /:arada'i o,.. Callaway Golf C., l>Ncftptlon 515/2021, 9:57:33 AM ASCE7-16 II D -Default (See Section 11.4.3) MCER ground motion. (for 0.2 second period) DHcriptlon MCER ground motion. (for 1.0s period) Site-modified spectral accele,ation value Site-modified spectral acceleration value Numeric seismic design value at 0.2 second SA Numeric seismic design value at 1.0 second SA Seismic design categ<lf)' Site amplification factor at O .2 second Site amplification factor at 1.0 second MC~ peak ground acceleration Site amplification factor at PGA Site modified peak ground acceleration Long-period transition period in seconds ProbabiNslic risk-targeted ground motion. (0.2 second) Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration Factored detenninislic acceleration value. (0.2 second) Probabitislic risk-targeted ground motion. (1.0 second) Factored uniform-hazard (2% probability of exceedance In 50 years) spectral acceleration. Factored detenninislic acceleration value. (1.0 11BCOnd) Factored detennlnlslic acceleration value. (Peak Ground Acceleration) Mapped value of Iha risk coefficient at short periods Mapped value of the risk coefficient et a period of 1 s ~ 0-P. ~<i)_,, Map data ©2021 https://seismicmaps.org 1/2 Hazardous Materials Questionnaire County of San Diego, Department of Environmental Health and Quality PO Box 129261, San Diego, CA 92112-9261 (858) 505-6700 (800) 253-9933 www.sdcdehq.org Record ID #: Not in System Plan Check#: DEH2021-HHMBP-010598 Balance Due: $397.00 Business Name Business Contact Eric Benson Telephone# Plan File# Argonaut Manufacturing services (176) 044-3476 Project Address 1896 Rutherford RD, BLDG# City Carlsbad State CA Zip Code 92008 APN# 212-120-62 Applicant Eric Benson he fol owing ques ons represent t e ac llty s act v es, t e specl project esc pt on. PART I' FIRE DEPARTMENT· HAZARDOUS MEIEBIALS DIVISION· OCCUPANCY CLASSIFICAJIQN:(Not required for projects within the City of San Diego.) Indicate by selectlng the Item, whether your business wtll use, process, or store any of the following hazardous materials. If any of the items are selected, Applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: Faclllty's Square Footage (including proposed project): 47500 □ Explosive or Blasting Agents □ □ Water Reactives !El Corrosives □ "' □ Compressed Gases Flammable/Combustible Liquids Flammable Solids "' □ Organic Peroxides Oxidizers IBt Cryogenics □ Other Health Hazards □ Pyrophorics Unstable Reactives □ Highly Toxic or Toxic Materials □ None of These □ Radioactlves PART n· SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH • HAZARDOUS MATERIALS DIVISION (HMD):lf the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Dlv!sion, in person at 5500 Overland Ave., Suite 110, San Diego, CA 92123, or by phone at(858) 505-6700 prior to Issuance of a bullding permit. FEES ARE REQUIRED. Project Completion Date: YES NO 1. !Bl □ 2. ~ □ 3. □ li1J 4. □ 5. □ 6. □ 7. □ 8. □ □ llil llil llil llil Is your business listed on the reverse side of this fonn? (check all that apply). Will your business dispose of Hazardous Substances or Medical Waste In any amount? Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds, or 200 cubic feet? Will your business handle carcinogens or reproductive toxins in any quantity? WHI your business use an existing, or install an underground storage tank? WUI your business store or handle Regulated Substances (CalARP)? WIii your business use or Install a Hazardous Waste Tank System (Tltle 22, Article 10)? Will your business store petroleum in tanks or containers at your facility with a total storage capacity equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act). □ □. □: CalARP Exempt CalARP Required CalARP Complete Review Date: PART Ill; SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT CAPCP); If the answer to Question #1 is 'Yes' and the answer to auestlon #2 is 'No', the applicant must contact the APCD prior to the issuance of a building or demolition permit. If any answer to Questions #3, #4, or #5 Is 'Yes', the applicant must contact the APCD prior to the issuance of a building or demolition permit. If the answer to Question #3 or #4 is 'Yes', the applicant may need to submit an asbestos notification fonn to the APCD at least 10 working days prior to commencing demolition or renovation (some residential projects may be exempt from the notification requirements). Contact the APCD at 10124 Old Grove Road, San Diego, CA 92131 or telephone (858) 586-2600 for more information. 1. 2. 3. 4. YES NO "' □ "' □ □ llil □ llil Will any existing building materials be disturbed as part of this project? (If the answer Is 'Yes', an asbestos sur.-ey may be required.) Has a survey been performed to detennlne the presence of asbestos containing materials? Will the project involve handling or disturbance of any asbestos containing matertals? WIii the project involve the removal of any toad supporting structural member? 5. □ llil llil Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD factsheet at http://www.sdnpcd.org/info/facts/permits.pdf 6. □ (ANSWER ONLY JF QUESTION 5 IS 'YES') Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? Search the California School Directory at http://www_c{je.ca.gov/re/sd/ for publlc and private schools or contact the appropriate school district. Briefly describe business activities: Briefly describe proposed project: Life science / pharmaceutical manufacturing converttng warehouse space Into lab space. l declare under penalty of pe~ury that to the best of my knowledge and belief, the responses made herein are true and correct. tl!I; Fees Acknowledged: tl!I Eric Benson Name of Owner or Authorized Agent FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: BY: EXEMPT OR NO FURTHER INFORMATION REQUIRED COUNTY-HMO' APCD FOR OFFICIAL USE ONLY RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY COUNTY-HMO APCO 9/23/2021 Date DATE: __________ _ RELEASED FOR OCCUPANCY COUNTY-HMO APCO *A stamp in this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply. DEHQ_HMD_HMBP _Questionnaire v 2,0 (8/2021) Printed on: 10/6/2021 @ 3:05 PM ( City of Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of permits are not required to fill out this form ❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool "' If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. "' Details on CAP ordinance requirements are available on the city's website. "' A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and download the latest form. Project Name/Building Permit No.: Property Address/APN: Applicant Name/Co.: Applicant Address: Contact Phone: Rutherford Manufacturing Area Project BP No. Cft:_f}t,;;1! -0311 Eric Benson 2841 Loker Ave E, Carlsbad CA 92010 760-443-4 762 Contact Email: ebenson@argonautms.com Contact information of person completing this checklist (if different than above): Name: Company name/address: Contact Phone: Contact Email: Applicant Signature: -~/2~~~-~-%~·-_~Y __ : _______ Date: Z.1 S Gp 2-I 8-50 Page 1 of 6 Revised 06/18 I Building Permit Valuation for Argonaut Rutherford Manufacturing Area Project 1896 Rutherford Road, Carlsbad CA 92008 Subject Architectural and Engineering Planning Fees Construction Mechanical Electrical Plumbing Total Amount $109,088 $969,946 $609,785 $286,468 $106,925 $2,082,212