Loading...
HomeMy WebLinkAboutDWG 531-4A; PD 2021-0021; 3460 ROOSEVELT STREET; 01-05AM GRADING NOTES (IN ADDITION TO THE REQUIREMENTS OF CHAPTER 15.16 OF THE CARLSBAD MUNICIPAL CODE.) 1. THIS PLAN SUPERSEDES ALL OTHER PLANS PREVIOUSLY APPROVED BY THE CITY OF CARLSBAD REGARDING GRADING SHOWN ON THIS SET OF PLANS. 2. APPROVAL OF THIS PLAN DOES NOT LESSEN OR WAIVE ANY PORTION OF THE CARLSBAD MUNICIPAL CODE, RESOLUTION OF CONDITIONAL APPROVAL, CITY STANDARDS OR OTHER ADDITIONAL DOCUMENTS LISTED HEREON AS THEY MAY PERTAIN TO THIS PROJECT. THE ENGINEER IN RESPONSIBLE CHARGE SHALL REVISE THESE PLANS WHEN NON-CONFORMANCE IS DISCOVERED. J. CITY APPROVAL OF PLANS DOES NOT RELIEVE THE DEVELOPER OR ENGINEER-OF- WORK FROM RESPONSIBILITY FOR THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. ALL PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE CITY ENGINEER FOR APPROVAL. 4. A RIGHT-OF-WAY PERMIT FROM THE CITY ENGINEER WILL BE REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT OF WAY. PRIOR TO PERMIT ISSUANCE, A CERT/FICA TE OF INSURANCE AS WELL AS ADDITIONAL INSURED ENDORSEMENT MUST BE FILED NAMING THE CITY OF CARLSBAD AS AN ADDITIONAL INSURED ON THE PERMITTEE'S POLICY IN THE MINIMUM AMOUNT OF $1,000,000.00 FOR EACH OCCURRANCE OF LIABILITY. THE INSURANCE COMPANY WRITING THE POLICY MUST HAVE A RATING OF "A-" OR BETTER AND A SIZE CATEGORY OF CLASS VII OR BETTER AS ESTABLISHED BY "BESTS" KEY RA TING GUIDE. 5. NO WORK SHALL BE COMMENCED UNTIL ALL PERMITS HAVE BEEN OBTAINED FROM THE CITY AND OTHER APPROPRIATE AGENCIES. 6. APPROVAL OF THESE PLANS BY THE CITY ENGINEER DOES NOT AUTHORIZE ANY WORK OR GRADING TO BE PERFORMED UNTIL THE PROPERTY OWNER'S PERMISSION HAS BEEN OBTAINED AND A VALID GRADING PERMIT HAS BEEN ISSUED. 7. NO REVISIONS WILL BE MADE TO THESE PLANS WITHOUT THE WRITTEN APPROVAL OF THE CITY ENGINEER, NOTED WITHIN THE REVISION BLOCK, ON THE APPROPRIATE SHEET OF THE PLANS AND THE TITLE SHEET. 8. ORIGINAL DRAWINGS SHALL BECOME THE PROPERTY OF THE CITY UPON BEING SIGNED BY THE CITY ENGINEER. 9. THE ORIGINAL ORA WING SHALL BE REVISED TO REFLECT AS-BUILT CONDITIONS BY THE ENGINEER-OF-WORK PRIOR TO FINAL ACCEPTANCE OF THE WORK BY THE CITY. 10. ACCESS FOR FIRE AND OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED TO THE PROJECT SITE AT ALL TIMES DURING CONSTRUCTION. 11. WHERE TRENCHES ARE WITHIN CITY EASEMENTS, A SOILS REPORT COMPRISED OF: (A) SUMMARY SHEET, (B) LABORATORY WORK SHEETS AND (C) COMPACTION CURVES, SHALL BE SUBMITTED BY A PROFESSIONAL ENGINEER OF THE STA TE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. THE SOILS REPORT WILL BE SUBMITTED TO THE CITY ENGINEERING INSPECTOR WITHIN TWO WORKING DAYS OF THE COMPLETION OF FIELD TESTS. 12. A SOILS COMPACTION REPORT AND COMPLIANCE VER/FICA TION REGARDING ADHERENCE TO RECOMMENDATIONS OUTLINED IN THE SOILS REPORT IS REQUIRED PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALL CONTROLLED GRADING SHALL BE DONE UNDER THE DIRECTION OF A PROFESSIONAL ENGINEER OF THE STA TE OF CALIFORNIA PR/NC/PALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. ALL FILL OR FUTURE FILL AREAS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY OF CARLSBAD STANDARD SPECIF/CATIONS AND THE " EARTHWORK SPECIF/CATIONS " ATTACHED TO THE PRELIMINARY SOILS INVEST/GA TION. DAILY FIELD COMPACTION REPORTS WILL BE SUBMITTED TO THE PROJECT INSPECTOR. 13. A PRECONSTRUCTION MEETING SHALL B£ HELD AT TH£ SITE PRIOR TO TH£ BEGINNING OF WORK AND SHALL BE ATTENDm BY ALL REPRESENTATIVES RESPONSIBLE FOR CONSTRUCTION, INSPECTION, SUPERVISION, TESTING AND ALL OTHER ASPECTS OF THE WORK, THE CONTRACTOR SHALL REQUEST A PRECONSTRUCTION MEETING BY CALLING THE INSPECTION LINE AT (760) 438-3891 AT LEAST FIVE(5) WORKING DAYS PRIOR TO STARTING CONSTRUCTION. THE CONTRACTOR WILL THEN BE CONTACTED BY THE PROJECT INSPECTOR TO COORDINATE A DA TE AND TIME FOR THE PRE CONSTRUCTION MEETING. APPROVED ORA WINGS MUST BE AVAILABLE PRIOR TO SCHEDULING. THE GRADING PERMIT WILL BE PROVIDED BY THE PROJECT INSPECTOR AT THE MEETING. 14. All INSPECTION REOlJESTS 01HFR WAN FOR PRECONS/RUCTION MEETING W1l I BE MAD[ BY CALLING 1HF ENGINEER/NG 24-HOUR IN5PECTION REOUEST LINE AT (760) 438-3891. INSPECTION REOUEST MUST BF RECEIY[D PRIOR TO 2: 00 P.M. ON THE DAY BEFORE THE INSPECTION IS NEEDED. INSPECTIONS WILL BE MADE THE NEXT WORK DAY UNLESS YOU REQUEST OTHERWISE. REQUESTS MADE AFTER 2: 00 P.M. WILL BE SCHEDULED FOR TWO FULL WORK DAYS LATER. 15. THE OWNER AND/OR APPLICANT THROUGH THE DEVELOPER AND/OR CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEWCES, INCLUDING SHORING, AND SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. 16. THE CONTRACTOR SHALL CONFORM TO LABOR CODE SECTION 6705 BY SUBMITTING A DETAIL PLAN TO THE CITY ENGINEER AND/OR CONCERNED AGENCY SHOWING THE DESIGN OF SHORING, BRACING SLOPING OR OTHER PROWSIONS TO BE MADE OF WORKER PROTECTION FROM THE HAZARD OF CAWNG GROUND DURING THE EXCAVATION OF SUCH TRENCH OR TRENCHES OR DURING THE PIPE INSTALLATION THEREIN. THIS PLAN MUST BE PREPARED FOR ALL TRENCHES FIVE FEET (5') OR MORE IN DEPTH AND APPROVED BY THE CITY ENGINEER AND/OR CONCERNED AGENCY PRIOR TO EXCAVATION. IF THE PLAN VAR/FS FROM 1HF SHORING SYSTEM STANDARDS ESTABLISHED BY THE CONSTRUCTION SAFETY ORDERS, TITLE 8 CALIFORNIA ADMINISTRATIVE CODE, THE PLAN SHALL BE PREPARED BY A REGISTERED ENGINEER AT TH£ CONTRACTORS EXPENSE A COPY OF THE OSHA EXCAVATION PERMIT MUST BE SUBMITTED TO THE INSPECTOR PRIOR TO EXCAVATION. 17. NO BLASTING SHALL BE PERFORMED UNTIL A VALID BLASTING PERMIT HAS BEEN OBTAINED FROM THE CITY OF CARLSBAD. SUBMIT APPL/CATION FOR BLASTING PERMIT WELL IN ADVANCE OF THE SCHEDULING OF BLASTING OPERATIONS. 18. IF ANY ARCHAEOLOGICAL RESOURCES ARE DISCOVERED WITHIN ANY WORK AREA DURING CONSTRUCTION, OPERATIONS WILL CEASE IMMEDIATELY AND THE PERMITTEE WILL NOTIFY THE CITY ENGINEER. OPERA T/ONS WILL NOT RESTART UNTIL THE PERMITTEE HAS RECEIVED WRITTEN AUTHORITY FROM THE CITY ENGINEER TO DO SO. 19. ALL OPERATIONS CONDUCTED ON THE SITE OR ADJACENT THERETO, INCLUDING WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR OPERATION OF TRUCKS, EARTHMOWNG EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOC/A TED GRADING EQUIPMENT SHALL BE LIMITED TO THE PERIOD BETWEEN 7: 00 A.M. AND 6: 00 P.M. EACH DAY, MONDAY THRU FRIDAY AND NO EARTHMOWNG OR GRADING OPERATIONS SHALL BE CONDUCTED ON WEEKENDS OR HOLIDAYS. (A LIST OF CITY HOLIDAYS IS AVAILABLE AT THE ENGINEERING DEPARTMENT COUNTER.) 20. ALL OFF-SITE HAUL ROUTES SHALL BE SUBMITTED BY THE CONTRACTOR TO THE CITY ENGINEER FOR APPROVAL TWO FULL WORKING DAYS PRIOR TO BEGINNING OF WORK. 21. IMPORT MATERIAL SHALL BE OBTAINED FROM, AND WASTE MATERIAL SHALL BE DEPOSITED AT, A SITE APPROVED BY THE CITY ENGINEER. TH£ CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTES OR ADJACENT STREETS AS A RESULT OF THE GRADING OPERATION. 22. BRUSH SHALL BE REMOVED ONLY WITHIN THE AREA TO BE GRADED. NO TREES ARE TO BE REMOVED UNLESS SPECIF/CALLY NOTED ON THE PLAN. 23. ALL AREAS SHALL BE GRADED TO DRAIN. GRADING RESULTING IN THE PONDING OF WATER IS NOT PERMITTED. ALL EARTHEN SWALES AND DITCHES SHALL HA VE A MINIMUM ONE PERCENT SLOPE. 24. THESE PLANS ARE SUBJECT TO A SIGNED AND APPROVED SWPPP AND/OR SET OF EROSION CONTROL PLANS. EROSION CONTROL SHALL BE AS SHOWN AND AS APPROVED BY THE CITY ENGINEER OR AS DIRECTED BY THE PROJECT INSPECTOR. 25. ALL SLOPES SHALL BE TRIMMED TO A FINISH GRADE TO PRODUCE A UNIFORM SURFACE AND CROSS SECTION. THE SITE SHALL BE LEFT IN A NEAT AND ORDERLY CONDITION. ALL STONES, ROOTS OR OTHER DEBRIS SHALL BE REMOVED AND DISPOSED OF AT A SITE APPROVED OF BY THE CITY ENGINEER. 26. ALL SLOPES SHALL BE /RR/GA TED, STABILIZED, PLANTED AND/OR HYDROSEEDED WITHIN TEN (10) DAYS OF THE TIME WHEN EACH SLOPE IS BROUGHT TO GRADE AS SHOWN ON THE APPROVED GRADING PLANS. 27. LANDSCAPING SHALL BE ACCOMPLISHED ON ALL SLOPES AND PADS AS REQUIRED BY THE CITY OF CARLSBAD LANDSCAPE MANUAL, THE LANDSCAPING PLANS FOR THIS PROJECT, DRAWING NO.=---• AND/OR AS DIRECTED BY THE CITY ENGINEER OR PLANNING DIRECTOR. K: \Civil JD\1485\DWG\PGP\ 1485-PGP-01.dwg Oct 29, 2021 -1: 10pm 28. THE OWNER/APPLICANT SHALL INSURE THAT ALL CONTRACTORS SHALL COORDINATE THE WORK OF THESE GRADING PLANS WITH THAT SHOWN ON BOTH THE LANDSCAPE AND /RR/GA TION PLANS AND THE IMPROVEMENT PLANS AS REQUIRED FOR THIS WORK IN ACCORDANCE WITH THE LANDSCAPE MANUAL TIME REQUIREMENTS. 29. WHERE AN EXISTING PIPE LINE IS TO BE ABANDONED AS A RESULT OF THE GRADING OPERATION, IT SHALL BE REMOVED WITHIN TWENTY FEET OF BUILDING OR STREET AREAS AND REPLACED WITH PROPERLY COMPACTED SOILS. IN OTHER AREAS THE PIPE WILL BE PLUGGED WITH CONCRETE OR REMOVED AS APPROVED BY THE CITY ENGINEER. JO. THE CONTRACTOR SHALL VERIFY THE LOCA T/ON OF ALL EXISTING FACILITIES ( ABOVE GROUND AND UNDER GROUND ) WITHIN THE PROJECT SITE SUFFICIENTLY AHEAD OF GRADING TO PERMIT THE REWSION OF THE GRADING PLANS IF IT IS FOUND THAT THE ACTUAL LOCATIONS ARE IN CONFLICT WITH THE PROPOSED WORK. 31. THE CONTRACTOR SHALL NOTIFY AFFECTED UTILITY COMPANIES (SEE BELOW) AT LEAST 2 FULL WORKING DAYS PRIOR TO STARTING GRADING NEAR THEIR FACILITIES AND SHALL COORDINATE THE WORK WITH A COMPANY REPRESENTATIVE. UNDERGROUND SERWCE ALERT (DIG ALERT) 811 SDG&E (800)411 -7343 AT&T (619)237-2787 SPECTRUM CABLE (800)227-2600 COX COMMUNICATIONS (619)262-1122 CITY OF CARLSBAD(STREETS & STORM DRAIN) (760)434-2980 CITY OF CARLSBAD(SEWER,WATER & RECLAIMED WATER) (760)438-2722 32. PERMIT COMPLIANCE REQUIREMENTS: A. FOR CONTROLLED GRADING -THE APPLICANT HIRES A CIWL ENGINEER, SOILS ENGINEER, AND/OR GEOLOGIST TO GIVE TECHNICAL ADWCE, OBSERVE AND CONTROL THE WORK IN PROGRESS /15.16 .120 A.BJ CARLSBAD MUNICIPAL CODE. B. PRIOR TO COMPLETION OF GRADING WORK THE FOLLOWING REPORTS MUST BE SUBMITTED TO THE CITY ENGINEER WA THE PROJECT INSPECTOR PER SECTION 15.16.120 OF THE CARLSBAD MUNICIPAL CODE: (1) FINAL REPORT BY SUPERWSING GRADING ENGINEER STA TING ALL GRADING IS COMPLETE. ALL EROSION CONTROL, SLOPE PLANTING AND /RR/GA TION ARE INSTALLED IN CONFORMANCE WITH CITY CODE AND THE APPROVED PLANS (OBTAIN SAMPLE OF COMPLIANCE LETTER FROM CITY ENGINEERING DEPARTMENT). (2) AS-BUILT GRADING PLAN. (3) REPORT FROM THE SOILS ENGINEER, WHICH INCLUDES RECOMMENDED SOIL BEARING CAPACITIES, A STATEMENT AS TO THE EXPANSIVE QUALITY OF THE SOIL, AND SUMMARIES OF FIELD AND LABORATORY TESTS. THE REPORT SHALL ALSO INCLUDE A STATEMENT BY THE SOILS ENGINEER THAT THE GRADING WAS DONE IN ACCORDANCE WITH THE REQUIREMENTS AND RECOMMENDATIONS OUTLINED IN THE PRELIMINARY SOILS RE:PORT AND ANY SUPPLEMENTS THERETO. (4) REPORT WITH AS-BUILT GEOLOGIC PLAN, IF REQUIRED BY THE CITY. (5) PERMANENT STRUCTURAL BMP INSTALLATION CERT/FICA TE. (6) PERMITTED WALL FINAL INSPECTION REPORT. 33. UNLESS A GRADING PERMIT FOR THIS PROJECT IS ISSUED WITHIN ONE (1) YEAR AFTER THE CITY ENGINEER'S APPROVAL, THESE PLANS MAY BE REQUIRED TO BE RESUBMITTED FOR PLANCHECK. PLANCHECK FEES WILL BE REQUIRED FOR ANY SUCH RECHECK. 34. IN ACCORDANCE WITH THE CITY STORM WATER STANDARDS. ALL STORM DRAIN INLETS CONSTRUCTED BY THIS PLAN SHALL INCLUDE "STENCILS" BE ADDED TO PROHIBIT WASTEWATER DISCHARGE DOWNSTREAM. STENCILS SHALL BE ADDED TO THE SATISFACTION OF THE CITY ENGINEER. "DECLARATION OF RESPONSIBLE CHARGE" I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT I HA VE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY CITY OF CARLSBAD DOES NOT RELIEVE ME, AS ENGINEER OF WORK, OF RESPONSIBILITIES FOR PROJECT DESIGN. THE MY FIRM: BHA INC. ADDRESS: 5115 AVENIDA ENCINAS CITY, STA TE: CARLSBAD CA SUITE L ~YESSI041, :#, RONALD L. ( ~ R HOIJ.Oll'AY e, t NO. 29271 ~ TELEPHONE: 760 931-8700 BY: ___ 1<fu(0---~___tl ~~~'1.L'.=~-DATE: 10-28-21 RONALD L. HOLLOWAY R.C.E. N0.:~2=9=2~71~ ___________ _ REGISTRATION EXPIRATION DATE:_=OJ~-~3~1-~2=3~ ___ _ SOILS ENGINEER'S CERTIFICATE EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC. SANTEE, CA 92071 (619) 258-7901 OWNER'S CERTIFICATE ~ <'!VJ\./.$ ~or e•"'~/ I ( WE ) HEREBY CERTIFY THAT A REGISTERED SOILS ENGINEER OR GEOLOGIST HAS BEEN OR WILL BE RETAINED TO SUPERVISE OVER-ALL GRADING ACTIVITY AND ADVISE ON THE COMPACTION AND STABILITY OF THIS SITE. IF THIS PROJECT/DEVELOPMENT IS SUBJECT TO A STA TE- REGULA TED SWPPP, I (WE) ALSO AGREE A QUALIFIED SWPPP PRACTITIONER (QSP) HAS BEEN OR WILL BE RETAINED TO SUPERWSE IMPLEMENTATION OF THE SWPPP IN ACCORDANCE WITH THE CALIFORNIA CONSTRUCT/ON ORDER AND MUNICIPAL PERMIT, LA TEST VERSION. 3460 ROOSEVELT LLC. A CALIFORNIA LIMITED LIABILITY COMPANY Craig Correll, Member Nov. 1, 2021 BY: CRAIG CORRELL, MEMBER SOURCE OF TOPOGRAPHY DATE TOPOGRAPHY SHOWN ON THESE PLANS WAS GENERA TED BY FIELD SURVEY METHODS FROM INFORMATION GATHERED ON NOVEMBER 20, 2020 BY "BHA, INC." SHOWN HEREON CONFORMS TO NA T/ONAL MAP ACCURACY STANDARDS. PROJECT LOCATION THIS PROJECT IS LOCATED WITHIN ASSESSORS PARCEL NUMBER(S) 204-172-35 THE CALIFORNIA COORDINATE INDEX OF THIS PROJECT IS: N 20003405 E 6226517 EROSION CONTROL NOTES 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT CRAIG CORRELL (760) 434-6800 (PHONE NUMBER) AT 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON. ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE AT CONVENIENT LOCA T/ONS TO FAG/LITA TE RAPID CONSTRUCTION OF TEMPORARY DEWCES WHEN RAIN IS EMINENT. J. FOR PROJECTS COVERED BY STATE SWPPP /WDID, IN ACCORDANCE WITH THE CONSTRUCTION ORDER ISSUED BY THE CALIFORNIA REGIONAL WATER QUALITY CONTROL BOARD, THE QUALIFIED SWPPP PRACTITIONER (QSP) SHALL UPDATE AND MAINTAIN THE WATER POLLUTION CONTROL (WPC) PLAN TO ADORESS UPDATED SITE CONDITIONS OF THE PROJECT. THE UPDATED WPC PLAN AND UPDATED SWPPP SHALL BE KEPT AT THE PROJECT SITE AND MADE AVAILABLE TO THE CITY INSPECTOR. ADDITIONAL CONSTRUCTION BMP'S BEYOND THE ORIGINAL APPROVED SWPPP SHALL BE PROWDED TO ADDRESS SITE CONDITIONS NOT ANTIC/PA TED. THE QSP SHALL REPORT BMP DEFICIENCIES TO THE CITY INSPECTOR. THE QSP SHALL OBTAIN APPROVAL FROM THE QUALIFIED SWPPP DEVELOPER AND THE CITY INSPECTOR REGARDING ANY SIGNIFICANT CHANGES TO BMP DEPLOYMENT. 4. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEWCES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. 5. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS WHERE IMPOUNDED WATERS CREATE A HAZARDOUS CONDITION. 7. ALL EROSION CONTROL MEASURES PROWDED PER THE APPROVED SWPPP AND/OR EROSION CONTROL PLAN SHALL BE INCORPORATED HEREON. 8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORKING DAY 9. ALL REMOVABLE PROTECTIVE DEWCES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FIFTY PERCENT (50%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. 10. ALL GRAVEL BAGS SHALL BE BURLAP TYPE WITH J/4 INCH MINIMUM AGGREGRATE. 11. SHOULD GERMINATION OF HYDROSEEDED SLOPES FAIL TO PROWDE EFFECTIVE COVERAGE OF GRADED SLOPES (90% COVERAGE) PRIOR TO NOVEMBER 15, THE SLOPES SHALL BE STABILIZED BY PUNCH STRAW INSTALLED IN ACCORDANCE WITH SECTION 35.023 OF THE EROSION AND SEDIMENT CONTROL HANDBOOK OF THE DEPARTMENT OF CONSERVATION, STATE OF CALIFORNIA. TEMPORARY EROSION CONTROL PLANTING AND IRRIGATION ALL PERMANENT AND TEMPORARY EROSION CONTROL PLANTING AND /RR/GA TION SHALL BE INSTALLED AND MAINTAINED AS REQUIRED IN SECTION 212 OF THE STANDARD SPECIF/CATIONS AND THE FOLLOWING: A. HYDROSEEDING SHALL BE APPLIED TO: 1. ALL SLOPES THAT ARE GRADED 6: 1 (HORIZONTAL TO VERTICAL) OR STEEPER WHEN THEY ARE: a. THREE FEET OR MORE IN HEIGHT AND ADJACENT TO A PUBLIC WALL OR STREET. b. ALL SLOPES 4 FEET OR MORE IN HEIGHT. 2. AREAS GRADED FLATTER THAN 6: 1 WHEN ANY OF THE FOLLOWING CONDITIONS EXIST: a. NOT SCHEDULED FOR IMPROVEMENTS(CONSTRUCTION OR GENERAL LANDSCAPING) WITHIN 60 DAYS OF ROUGH GRADING. b. IDENTIFIED BY THE PARKS AND RECREATION DIRECTOR AS HIGHLY WSIBLE TO THE PUBLIC. c. HA VE ANY SPECIAL CONDITION IDENTIFIED BY THE CITY ENGINEER THAT WARRANTS IMMEDIATE TREATMENT. 8. HYDROSEEDED AREAS SHALL BE /RR/GA TED IN ACCORDANCE WITH THE FOLLOWING CRITERIA: 1. ALL SLOPES THAT ARE GRADED 6: 1 OR STEEPER AND THAT ARE: a. THREE TO EIGHT FEET IN HEIGHT SHALL BE /RR/GA TED BY HAND WATERING FROM QUICK COUPLERS/HOSE BIBS OR A CONVENTIONAL SYSTEM OF LOW PRECIPITATION SPRINKLER HEADS PROWDING 100% COVERAGE. b. GREATER THAN 8 FEET IN HEIGHT SHALL BE WATERED BY A CONVENTIONAL SYSTEM OF LOW PRECIPITATION SPRINKLER HEADS PROWDING 100% COVERAGE. 2. AREAS SLOPED LESS THAN 6: 1 SHALL BE /RR/GA TED AS APPROVED BY THE CITY ENGINEER, PRIOR TO HYDROSEEDING. THE DEVELOPER SHALL SUBMIT A PROPOSED SCHEME TO PROWDE /RR/GA TION TO THE CITY ENGINEER. THE PROPOSAL SHALL BE SPECIFIC REGARDING THE NUMBERS, TYPES AND COSTS OF THE ELEMENTS OF THE THE PROPOSED SYSTEM. J. /RR/GA TION SHALL MAINTAIN THE MOISTURE LEVEL OF THE SOIL AT THE OPTIMUM LEVEL FOR THE GROWTH OF THE HYDROSEEDED GROWTH. C. HYDROSEEDING MIX SHALL CONSIST OF ALL OF THE FOLLOWING: 1. SEED MIX SHALL CONSIST OF NO LESS THAN: a. 20 lbs. PER ACRE OF ROSE CLOVER b. 20 lbs. PER ACRE OF ZORRO FESCUE c. J lbs. PER ACRE OF E SCHOOL CIA CALIFORNICA d. 4 lbs. PER ACRE OF ACHILLEA MILLEFOLIA e. J lbs. PER ACRE OF AL YSSUM (CARPET OF SNOW) f. 1/2 lb. PER ACRE OF D/MORPHOLECA g. ITEMS c,d,e, AND f OF THIS SUBSECTION MAY BE OMITTED ON LOCATIONS WHERE THE AREA BEING HYDROSEEDED IS NOT WSIBLE FROM EITHER A PUBLIC STREET OR RESIDENTIAL STRUCTURES. h. ITEM a OF THIS SUBSECTION MUST BE INOCULATED WITH A NITROGEN FIXING BACTERIA AND APPLIED DRY EITHER BY DRILLING OR BROADCASTING BEFORE HYDROSEEDING. i. ALL SEED MATERIALS SHALL BE TRANSPORTED TO THE JOBS/TE IN UNOPENED CONTAINERS WITH THE CALIFORNIA DEPARTMENT OF FOOD AND AGR/CUL TUR£ CERT/FICA TION TAG ATTACHED TO, OR PRINTED ON SAID CONTAINERS. j. NON-PHYTO-TOX/C WETTING AGENTS MAY BE ADDED TO THE HYDROSEED SLURRY AT THE DISCRETION OF THE CONTRACTOR. 2. TYPE 1 MULCH APPLIED AT THE RA TE OF NO LESS THAN 2000 lbs PER ACRE. TYPE 6 MULCH (STRAW) MAY BE SUBSTITUTED, ALL OR PART, FOR HYDRAULICALLY APPLIED FIBER MATERIAL. WHEN STRAW IS USED IT MUST BE ANCHORED TO THE SLOPE BY MEGHAN/CALLY PUNCHING NO LESS THAN 50% OF THE STRAW INTO THE SOIL. J. FERTILIZER CONSISTING OF AMMONIUM PHOSPHATE SULFA TE, 16-20-0, WITH 15% SULPHUR APPLIED AT THE RA TE OF 500 lbs. PER ACRE. D. AREAS TO BE HYDROSEEDED SHALL BE PREPARED PRIOR TO HYDROSEED/NG BY: 1. ROUGHENING THE SURFACE TO BE PLANTED BY ANY OR A COMB/NATION OF: a. TRACK WALKING SLOPES STEEPER THAN 6: 1 b. HARROWING AREAS 6: 1 OR FLATTER THAT ARE SUFFICIENTLY FRIABLE. c. RIPPING AREAS THAT WILL NOT BREAK UP USING ITEMS a OR b ABOVE. 2. CONDITION/NG THE SOILS SO THAT IT IS SUITABLE FOR PLANTING BY: a. ADJUSTING THE SURFACE SOIL MOISTURE TO PROWDE A DAMP BUT NOT SATURATED SEED BED. b. THE ADDITION OF SOIL AMENDMENTS, PH ADJUSTMENT, LEACHING COVERING SALINE SOILS TO PROWDED WABLE CONDITIONS FOR GROWTH. E. HYDROSEEDED AREAS SHALL BE MAINTAINED TO PROWDE A WGOROUS GROWTH UNTIL THE THE PROJECT IS PERMANENTLY LANDSCAPED OR, FOR AREAS WHERE HYDROSEEDING IS THE THE PERMANENT LANDSCAPING, UNTIL THE PROJECT IS COMPLETED AND ALL BONDS RELEASED. F. ALL SLOPES SHALL HA VE /RR/GA TION INSTALLED AND BE STABILIZED, PLANTED AND/OR HYDROSEEDED WITHIN TEN (10) DAYS OF THE TIME WHEN EACH SLOPE IS BROUGHT TO GRADE AS SHOWN ON THE APPROVED GRADING PLANS. AN APPROVED EROSION CONTROL PRODUCT (RECP) SHALL BE INSTALLED PER EC-7 IF THIS REQUIREMENT CANNOT BE MET. JUTE, EXCELSIOR OR STRAW BLANKET IS UNACCEPTABLE. G. SHOULD GERM/NATION OF HYDROSEED FAIL TO PROWDE EFFICIENT COVERAGE (NO LESS THAN 70%) PRIOR TO OCTOBER 1, THE SLOPES SHALL BE STABILIZED BY AN APPROVED RECP. JUTE, EXCELSIOR AND STRAW BLANKET IS UNACCEPTABLE. H. LANDSCAPING SHALL BE ACCOMPLISHED ON ALL SLOPES AND PADS AS REQUIRED BY THE CITY LANDSCAPE MANUAL, THE LANDSCAPE PLANS FOR THIS PROJECT OR AS DIRECTED BY THE CITY ENGINEER OR CITY PLANNER. ----------->-§ -----------" EXISTING FIRE ---0 HYDRANT KEY MAP SCALE: 1" = 50' PINE PARK "' ,\\ \\ '"' % 5 "'> 'D-'\ CHASE . ,? v> FIELD '"' V. «-"2, ~ 0~ v p r CT SI \ . ,,, '."\ ' • \ MAGNOLIA AVE. VICINITY MAP NOT TO SCALE SHEET INDEX 1 TITLE S HEET 2 PRECIS E GRADING PLAN 3 WALL P LANS 4 TIER 2 SWPPP COVER 5 TIER 2 SWPP EROSION CONTROL SCRIPTION LEGAL DE LOT FIVE (5) THE CITY OF CALIFORNIA, THE OFFICE IN BLOCK 43 OF THE TOWNS/TE OF CARLSBAD, IN CARLSBAD, COUNTY OF SAN DIEGO, STATE OF ACCORDING TO MAP THEREOF NO. 775, FILED IN OF THE RECORDER FEBRUARY 15, 1894. ADDRESS PROJECT VACANT LOT 3460 ROOS CARLSBAD, C EVELT STREET A. 92008 's PARCEL NUMBER EVELOPER ASSESSOR 204-172-35 OWNER/D 3460 ROOSEV 4245 SUNN~ CARLSBAD, C £LT LLC, A CALIFORNIA LIMITED LIABILITY COMPANY HILL DRIVE A 92008 REFEREN DWG 122-10 CE DRAWINGS , DWG 118-9 RK QUANTITIES EARTHWO CUT: __ FILL: __ IMPORT:_ EXPORT:_ REMEDIAL GR 18 CY 52 CY 34 CY 0 CY AD/NG:_ 1 JO CY BENCH MARK DESCRIPTION: ELEVATION IS BASED ON CITY OF CARLSBAD SURVEY CONTROL POINT #_130, 2.5" BRASS DISK E SOUTHEASTERLY CORNER OF A STORM DRAIN CURB INLET LOCA T/ON: TH A WA RECORDED:_ T THE NORTHEASTERLY RETURN OF GRAND A VE. AND SH/NGTON ST. RECQ&Q O[ SU{!V[Y 1 Z2Z1 ELEVATION: 40.91 MSL DATUM: b~A, Inc. land plan nlng, civil englnee~ng, surveying IDA ENCIN AS 5115 AVEN SUI TE "L" CARLSBAD (760) 931 , CA. 92008-4387 -8700 /j \ DATE INITIAL NGVD 29 WORK TO BE DONE THE GRADING WORK SHALL CONSIST OF THE CONSTRUCTION OF ALL CUTS AND FILLS, REMEDIAL GRADING, DRAINAGE FACILITIES, EROSION CONTROL FACILITIES, AND PLANTING OF PERMANENT LANDSCAPING AND PREPARATION OF AS-BUILT GRADING PLANS, AS-BUILT GEOLOGIC MAPS AND REPORTS, ALL AS SHOWN OR REQUIRED ON THIS SET OF PLANS AND THE CITY STANDARDS, SPECIF/CATIONS, REQUIREMENTS, RESOLUTIONS AND ORDINANCES CITED ON THESE PLANS. THE GRADING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FOLLOWING DOCUMENTS, CURRENT AT THE TIME OF CONSTRUCTION, AS DIRECTED BY THE CITY ENGINEER. 1. CARLSBAD MUNICIPAL CODE 2. CITY OF CARLSBAD ENGINEERING STANDARDS J. THIS SET OF PLANS 4. THE STANDARD SPECIF/CATIONS FOR PUBLIC WORKS CONSTRUCTION (GREEN BOOK). 5. SOILS REPORT AND RECOMMENDATIONS BY EAST COUNTY SOIL CONSULTATION & ENGINEERING INC. DA TED OCTOBER 10, 2020. 6. THE SAN DIEGO REGIONAL STANDARD ORA WINGS AND AS MAY BE MODIFIED BY THE CITY OF CARLSBAD STANDARDS. 7. TIER II STORM WATER POLLUTION PREVENTION PLAN PER THIS PLAN 8. STORM WATER QUALITY MANAGEMENT PLAN PREPARED BY N A DATED NIA ' 9. CALIFORNIA STORM WATER QUALITY ASSOC/A TION BMP CONSTRUCTION HANDBOOK ANO CAL TRANS CONSTRUCTION SITE BMP MANUAL. LEGEND DESCRIPTION DWG.NO. SYMBOL QUANTITY PROPERTY LINE ---- EXISTING SEWER MAIN/LATERAL (S) EXISTING WATER MAIN/LATERAL (W) EXISTING GAS MAIN -(GAS)- EXISTING RETAINING WALL 135 LF 4" PVC STORM DRAIN SD 4 " ROUND NDS GRATE @ 5 EA PROPOSED ROOF DRAIN DOWN SPOUT DS 8 EA COARSE GRAVEL FOR ROOF DOWN SPOUT li1:il J EA PAD {2'x2'x6" DEEP} EXISTING CONTOURS --1 00 -- FINISHED GROUND CONTOURS --1 00 -- EXISTING FIRE HYDRANT {PUBLIC) +-§ I /" WATER SERVICE W/1" METER CMWD W-5 ~ 1 EA & BACKFLOW DEVICE I 1" /RR/GA TION SERVICE CMWD W-J ~ 1 EA SERVICE W/ J/4" METER W-6 I & BACKFLOW DEVICE IMPERVIOUS DISPERSION AREA SE£ LANDSCAPE 1 ...... · .... 1 1 EA PLAN PERMEABLE PA VERS SEE DETAILS ~ 71 SF ON SHEET 2 l~1 ~1 ~1 ~1 ~1 l GROUTED PA VERS SEE DETAILS 538 SF ON SHEET 2 PROPOSED RETAINING WALL PER SHEET J 270 LF PROPOSED RETAINING WALL S/JRS/J C-01 21 LF BUILDING FOUNDA TION WALL PER SEPARATE IZZZZZZZ Z ZI BUILDING PERMIT TRENCH RESURFACING °CSD GS-26,GS-28 1 1 1 1 1 1 1 11 11 61 LF 2" GRIND & OVERLAY °CSD GS-26,GS-28 ~ 1,043 SF SIDEWALK UNDERDRAIN SDRSD 0-27 I 2 EA ' ABBREV/A TIONS CMWD -CARLSBAD MUNICIPAL WATER DISTRICT coc -CITY OF CARLSBAD SDRSD -SAN DIEGO REGIONAL STANDARD ORA WINGS STRUCTURAL (POST-CONSTRUCTION) BMP TABLE STORMWA TER REQUIREMENTS THAT APPLY: EXEMPT FROM HYDROMODIFICA TION? ~ STANDARD STORMWATER REQUIREMENTS PRIORITY PROJECT REQUIREMENTS ~ YES (SEE SWMP FOR DOCUMENTATION) NO TYPE DESCRIPTION OWNERSHIP MAINTENANCE SHEET NO. MAINTENANCE AGREEMENT FREQUENCY TOTAL LOT AREA = 3,502 SF (0.08 AC) "AS BUI LT" TOTAL DISTURBED AREA = 3,502 SF (0.08 AC) (THIS AREA INCLUDES BUT IS NOT LIMITED TO OFF-SITE WORK INCLUDING PUBLIC IMPROVEMENTS AND TEMPORARY DISTURBANCE SUCH AS VEHICLE AND EQUIPMENT STAGING AREAS, CONSTRUCTION RCE EXP, DATE WORKER FOOT TRAFFIC, SOIL/GRAVEL PILES, UTILITY TRENCHES, BACKFILL CUTS AND SLOPE KEYWA YS) REVIE',,IED BY• TOTAL REPLACED IMPERWOUS AREA = 0 SF (0.00 AC) TOTAL PROPOSED IMPERWOUS AREA -2, 757 SF (0.06 AC) INSPECTOR DA TE I SHf ET I CIT Y OF CARLSBAD I SH5 TS I ENGINEERING DEPARTMENT GRADING PLANS FOR: 3460 ROOSEVELT STREET GR2021-0017 TITLE SHEET APPROVED: JASON S. GELDERT ENGINEERING MANAGER PE 63912 EXPIRES 9/30/22 DATE OWN BY: AV PROJECT NO. DRAWING NO. DATE INITIAL DATE INITIAL CHKD BY: ENGINEER OF WORK REVISION DESCR IPTION OTHER APPROVAL CITY APPROVAL RVWD BY: PD2021-0021 DWG 531-4A DocuSign Envelope ID: 0DA00D45-3CFA-47B6-B7A7-2B9789C2D593 7/28/2022 AM ~ ~ ~ c:, -~ ~ :is f:l ~(/) bj 0, t ~ o~c -sc ~ I c., -Cl ,-.: ~ J> V) ~ c., ~ ~ ~ Cl J> ~4• 22+39.94 EXIST. 4" SEWER LATERA CONTRACTOR TO VE /FY LOCATION (40.28 IE±) 22+59.88 2• GAS S£ VICE CONN. TO EXIST. 4" AS LINE ~ BY SEPARATE APPLIC TION TO '1; SDG&E. NOT A PAR OF THIS PLAN;') __, ~ • !!i (0 i::: Q i-: :::, J.> (/) c., (/) x ~ "'~ I 5.18' MIN. 3.67' MIN. 2c...."=1t~69" ==r=-::J:. o:o~';M~IN~-;-~~ PROPOSED FENCE -IMPERVIOUS PA VERS RETAINING WALLS WITH FENCES ON PER PLAN TOP NOT TO EXCEED 6' IN TOTAL FL 1.50' ~~ ~~ ~ I' ) I :is kl co~ ~~ ,-.: c:, <e->--~ \!.) f5 "' [iE (/) c., is: &l ,-.: c::, ~ uJ uJ "-.:: ~ 2 • ~ .:: ~ GF HEIGHT---------2% MIN. • PROPOSED 6" BLOCK RETAINING ;:;:;111"'1 !;:;'Ill;;:; I c:-:III • •••... ,. -,-,"'"ii""F'""'iicriF"''n-- WALL PER DETAILS SH££.E:;T. GROU,'"'D ;__ .• ;: ii ~11ii'''\__····•u. ····•···••'' ....... ., ·•·•·• ..•• ,. :: : :i ; ' A/C, IY, ;;;) . • • -----,, ,_',. . 2• OF SAND PER • ·. GEO TECHNICAL J_ ,< ' ,,. ,L' RECOMMENDATIONS "' .• ,!,., '>._ ,· .!.. ,,. · • · . : . PER GEOECHNICAL RECOMMENDATIONS NO WALL SUBDRAINS ARE REQUIRED PER LETTER DA TED 07 /07 /21. SECTION A-A NOT TO SCALE 4.17' MIN. E SECTIONB-B NOT TO SCALE K: \Civil 30\1485\DWG\PGP\ 1485-PGP-02.dwg Jul 25, 2022 -11:43am EXISTING CURB & GUTTER I ) ----.l-t---1 -----1-"m+---,--~, I p MEASLE P VERs-+--rll'- 1 in S-u.. ID (.!) ~ .... N ID (.!) N "1-......: ai U1 .... (/) "-.... 00 fii ~ t== ~ -.;1-0 0 .,,_ <O ,.....: oi ci U"lv..,. 2 ' N c:, U1 c:, • • 0, (') .... ID (.!) (/) (/) "-"- 00 00 N 0 d d U1 U1 ~ t== ~ 00 N 00 ,.._ 0 c:, U1 dai lfl d "' .... -"' -----,-· · --[®~:-1-s-0J5;o -+-~ ~~.3oL -~l----1~ . _aaaL-;~l~i"------1----j~~,~~;j I ,:,:;:,1 1 ;~:g~ ~; ...... -"".'-"'. "'-!.:el 51.56 FF 51.14 FSSC-I li.J C-6 ~ ~ iili ,-.: ,-.: Q:: (/) (/) kl XI-x~ uJ Q:: 6" I 11' OJ "" .... ,-.: iili ~~ GS in N "' "'" .... (.!) -00 "100 "' "-U1 «>d --<O "' ..,..,, "' 0, ~ d ~ "' ~ ·S -"' ~ Q:: TT-"m'"=m= + 4 FS ~ u "<.T' (.!) --~ "-□r--c., WO lf!~LL. 0 "1 (') ... U1 -0, U1 00 o,-0 • • U1 ~~~ -t== "' ~ -"' "' d "' "' -"' 3.16' MIN. 2.49' MIN. _,. JADU s0 51.56 FF 50.B1 PAD E "' "' "' -....:d "' "' PER GEOECHNICAL RECOMMENDATIONS NO WALL SUBDRAINS ARE REQUIRED PER LETTER DA TED 07 /07 /21. ,1,_., •. ,:.c ,';·,::: ··, ,_, . , -'•. ' , -~ 16' 4' EXISTING SIDEWALK .. . SECTIONC-C NOT TO SCALE 1' 5.14' v-PROPERTY LINE I I 2% -- EXISTING RETAINING WALL SECTIONE-E NOT TO SCALE c., ~ "- 0, -0 -in in ~ t== 0 0 -U1 "' 1 MAIN ()J52.06 FF 51.31 PAD N 55°55'15"£ (.!) "--,.._ co 0 "' 3: t- ~ in 15.14' 2% - "' g 52.06 F 51.56 F 6 FS ~ 00 00 "' N -a. -U1 I "' I DS I 1 --c==:!-J. 139.99' ~ 00 00 d "' ~ t== 00 co ,.._ "' -d "' "' ~ ~ 0 w u --"' -: "'": "' -co --0, "' .... 12" OF 95% COMPACTED SUBGRADE in ~ t== «>ID ....:d U1 U1 2 ~ t== .... ~ -d -"' "' J-1/8" PERMEABLE PAVERS SLOPE PER PLAN PERMEABLE PA VER DETAIL ;:.. -lfi PER GEOTECHINCAL RECOMMENDATIONS PER LETTER DA TED 07 /07 /21 NOT TO SCALE 10· PROPOSED IMPERVIOUS PA VERS 2% - PROPOSED BUILDING FF -"' "] N 0 • U1 0 U1 ~ t== -"' 00 ,.._ cioi "' .... /1\ DATE INITIAL ENGINEER OF WORK ~ "' t== "- "' "' "' 0 0, "' .... .... ,,. I 10' ___ ,_ 10' ---2 ~ t G "cj ~ l 4" 6" 12" </9 s . 9 '2) P RMEABL P VERS VERL y t REVISION DESCRIPTION CONSTRUCTION NOTES [TI PORTION OF RETAINING WALL TO REMAIN IZ) PROP. RETAINING WALL PER WALL DETAILS ON SHEET J WITH WOODEN FENCE 6' MAX HEIGHT FROM FINISH GRADE. [J] COARSE GRAVEL PAD FOR ROOF DOWN DRAIN OUTLET (1.5'x1.5'x6" DEEP) UNLESS OTHERWISE SHOWN. [!I 4" PVC O 1.5% MIN. rn:) 2-3" PVC @ 2.0% MIN. [§] PORTION OF EXISTING WALL TO BE REMOVED II) RETAINING WALL PER SDRSD C-01 APPLICABLE STANDARD PROJECT SOURCE CONTROL AND SITE DESIGN flW1 SC-1 PREVENTION OF ILLICIT DISCHARGES SC-5 PROTECT TRASH STORAGE AREAS SC-6 ADDITIONAL BMPs FOR POTENTIAL RUNOFF POLLUTANTS SD-J MINIMIZE IMPERVIOUS AREA SD-4 MINIMIZE SOIL COMPACTION SD-5 IMPERVIOUS AREA DISPERSION SD-7 LANDSCAPING WITH NATIVE OR DROUGHT TOLERANT SPECIES 10· 5' o· 1 o· SCALE: 1" = 10' 20· 30' LEGEND OF ABBREVIATIONS AC ADU BW C&G CL co E EP FC FG FL FS G GB HP I JADU - GF DATE ASPHALT CONCRETE IE ACCESSORY DWELLING UNIT MH BOTTOM OF WALL NTS CURB AND GUTTER p CENTERLINE PICP CLEANOUT PVC ELECTRIC RW EDGE OF PAVEMENT s FACE OF CURB SD SG FINISHED GRADE SW FLOWUNE T FINISHED SURFACE GAS TB GRADE BREAK TC HIGH POINT TF TG IRRIGATION TW JUNIOR ACCESSORY DWELLING UNIT w 5.62' R/W .1----------------i SEE PROPOSED PERMEABLE INVERT ELEVATION MANHOLE NOT TO SCALE PAVEMENT PERMEABLE INTERLOCKING CONCRETE PAVERS POLYVINYL CHLORIDE RIGHT-OF-WAY SEWER STORM DRAIN SUBGRADE SIDEWALK TELEPHONE TOP OF BERM/DIKE TOP OF CURB TOP OF FOOTING TOP OF GRATE TOP OF WALL WATER PAVER$ PER DTL. THIS SHT. ALLEY 3-1/8" PERMEABLE PAVER$ EP ··/ .... ;,· ~-.. :· 2• OF ASTM NO. 8 BEDDING COURSE/CHOKE STONE INITIAL SECTIOND-D NOT TO SCALE bl-lA,lnc. ---4" OF ASTM NO. 57 STONE OPEN-GRADED BASE 6" OF ASTM NO. 2 STONE SUBBASE WRAPPED IN MIRAFI 180N GEOTEXTILE OR EQUIVALENT ---12• OF 95% COMPACTED SUBGRADE land planning, civil engineering, $l.11Veying ;fESS/ RONALD L. "' HOLLOWAY 5115 AVENIDA ENCINAS SUITE "L" CARLSBAD, CA. 92008-4387 (760} 931-8700 RONAL;If ~L~ 29271 . 3/31/23 RCE REVIEI.IED INSPECTOR CITY I NO. 29271 l'IVl\. 10-28-21 II AS BUIL T11 EXP. BY1 OF CARLSBAD I SH2ET I ENGINEERING DEPARTMENT GRADING PLANS FOR: DATE DATE I SH5TS I 3460 ROOSEVELT STREET GR2021-0017 PRECISE GRADING PLAN APPROVED: JASON S. GELDERT ENGINEERING MANAGER PE 63912 EXPIRES 9/30/22 DATE DWN BY: A'i. PROJECT NO. DRAWING NO. DATE INITIAL CHKD BY: OTHER APPROVAL CITY APPROVAL RVWD BY: PD2021-0021 DWG 531-4A DocuSign Envelope ID: 0DA00D45-3CFA-47B6-B7A7-2B9789C2D593 7/28/2022 2" AM DocuSign Envelope ID: 0DA00D45-3CFA-47B6-B7A7-2B9789C2D593 7/28/2022 TIER 2 CITY STORM WATER POLLUTION PREVENTION PLAN (TIER 2 SWPPP) STORM WATER POLLUTION PREVENTION NOTES GENERAL SITE MANAGEMENT REO/JIREMENTS THE FOLLOWING GENERAL SITE MANAGEMENT REQUIREMENTS SHALL BE ADHERED TO THROUGHOUT THE DURATION OF THE CONSTRUCTION WORK {YEAR ROUND). 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT;_· __ .,,CR"'A"'IG"-"COR,='R,.,,'ELL=--- A T {TEL.NO.) (760) 439-6800 2. DEVICES SHOWN ON CITY APPROVED PLANS SHALL NOT BE MOVED OR MOD/RED WITHOUT THE APPROVAL OF THE ENGINEERING INSPECTOR. 3. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. 4. THE CONTRACTOR SHALL INSTALL ADD!nONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORSEEN CIRCUMSTANCES WHICH MAY ARISE. 5. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBUC TRESPASS ONTO AREAS WHERE IMPOUNDED WATERS CREA TE A HAZARDOUS CONDITION. 6. GRAO/NG AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORKING DAY. 7. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT {40%}. SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. 8. ALL GRA VEl. BAGS SHALL CONTAIN 3/4 INCH MINIMUM AGGREGATE. 9. ALL EXPOSED DISTURBED AREAS MUST HA VE EROSION PROTECTION BMPs PROPERLY INSTALLED. THIS INCLUDES ALL BUILDING PADS, UNFINISHED ROADS, AND SLOPES. 10. ADEQUATE PERIMETER PROTECTION BMPs MUST BE INSTALLED AND MAINTAINED AND EROSION CONTROL HYDROSEEDING. PLANTING AND /RR/GA TION 1. ALL PERMANENT AND TEMPORARY EROSION CONTROL PLANTING AND /RR/GA TION SHALL BE INSTALLED AND MAINTAINED AS REQUIRED IN SECTION 212 OF THE STANDARD SPECIF/CATIONS AND THE FOLLOWING: A HYDROSEEDING SHALL BE APPLIED TO: 1 ALL SLOPES THAT ARE GRADED 6: 1 (HORIZONTAL TO VERTICAL) OR STEEPER WI-IEN THEY ARE: a. THREE FEET OR MORE IN HEIGHT AND ADJACENT TO PUBLIC WALL OR STREET. b. ALL SLOPES 4 FEET OR MORE IN HEIGHT. 2 AREAS GRADED FLATTER THAN 6: 1 WI-IEN ANY OF THE FOLLOWING COND!nONS EXIST: a. NOT SCHEDULED FOR IMPROVEMENTS {CONSTRUCTION OR GENERAL LANDSCAPING) WITHIN 60 DAYS OF ROUGH GRADING. b. IDENTIFIED BY THE PARKS AND RECREATION DIRECTOR AS HIGHL Y VISIBLE TO THE PUBUC. c. HA 1,£" ANY SPECIAL COND!nON IDENTIFIED BY THE CITY ENGINEER THAT WARRANTS IMMEDIATE TREATMENT. B HYDROSEEDING AREAS SHALL BE /RR/GA TED IN ACCORDANCE WITH THE FOLLOWING CRITERIA: 1 ALL SLOPES THAT ARE GRADED 6: 1 OR STEEPER AND THAT ARE: a. THREE TO EIGHT FEET IN HEIGHT SHALL BE IRRIGATED BY HAND WATERING FROM QUICK COUPLERS/HOSE BIBS OR A CONl-£"NTIONAL SYSTEM OF LOW PRECIPITATION SPRINKLER HEADS PROVIDING 100% COl-£"RAG£ b. GREATER THAN 8 FEET IN HEIGHT SHALL BE WATERED BY A CONl-£"NTIONAL SYSTEM OF LOW PRECIPITATION SPRINKLER HEADS PROVIDING 100% COVERAGE. .§ -.... " BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE Erosion Control Sediment Control BMPs Tracking Non-Storm Water Waste Management and Materials BMPs Control BMPs Management BMPs Pollution Control BMPs .§ .§ .§ --.., -5 .., 5 --0, " E § .., ., § " " .§ :§ ·[ 5 § --2 .s .9-.l!! :§l .., ., 0, .!11 --?:, 0, ., C: ., ., " C: ., --5 PINE PARK VICINITY MAP NOT TO SCALE SHEET INDEX· SHEET 4: TITLE SHEET SHEET 5: EROSION CONTROL PLANS APN: 204-172-35 WILL BE UPGRADED, IF NECESSARY, TO PROVIDE sumCIENT PROTECTION FROM RUNOFF DURING RAIN EVENTS. 2 AREAS SLOPED LESS THAN 6: 1 SHALL BE /RR/GA TED AS APPROl-£"0 BY THE CITY ENGINEER, PRIOR TO HYDROSEEDING. THE DEVEZ.OPER SHALL Best Management Practice* o-., C: 0, 0, ~ .s; 0, ! ·I .s; -Si Oo g. & ., 3" ., ,!:: ~ ~ .§-.!,! 5 ., ., g ~ C: ., 8 tr; i .,! ,11_ ., -0, 8~ ·-., --.,_ &o - 11. ADEQUATE SEDIMENT CONTROL BMPs MUST BE INSTALLED AND MAINTAINED. 12. ADEQUATE BMPs TO CONTROL OFFS/TE SEDIMENT TRACKING MUST BE INSTALLED AND MAINTAINED. 13. A MINIMUM OF 125% OF THE MATERIAL NEEDED TOO INSTALL STANDBY BMPs TO PROTECT THE EXPOSED AREAS FROM EROSION AND PREVENT SEDIMENT DISCHARGES, MUST BE STORED ONS/TE. AREAS ALREADY PROTECTED FROM EROSION USING PHYSICAL STABIUZA TION OR ESTABLISHED l-£"GETA TION STAB/LIZA TION BMPs ARE NOT CONSIDERED TO BE "EXPOSED" FOR PURPOSES OF THIS REQUIREMENT. 14. THE OWNER/DEl-£"LOPER/CONTRACTOR MUST FOLLOW "WEATHER TRIGGERED" ACTION PLAN AND BE ABLE TO DEPLOY STANDBY BMPs TO PROTECT THE EXPOSED PORTIONS OF THE SITE WITHIN 48 HOURS OF A PREDICTED STORM EVENT (A PREDICTED STORM EVENT IS DEFINED AS A 40% CHANCE OF RAIN WITHIN A 5-DA Y NATIONAL WEATHER SERVICE FORECAST). ON REQUEST, THE OWNER/DEVEZ.OPER/CONTRACTOR MUST PROVIDE PROOF OF THIS CAPABILITY. 15. DEPLOYMENT OF PHYSICAL OR VEGETATION EROSION CONTROL BMPs MUST COMMENCE AS SOON AS SLOPES ARE COMPLETED. THE OWNER/DEl-£"LOPER/CONTRACTOR MAY NOT RELY ON THE AB/UTY TO DEPLOY STANDBY BMP MATERIALS TO PREVENT EROSION OF SLOPES THAT HA l-£" BEEN COMPLETED. 16. THE AREA THAT CAN BE CLEARED, GRADED, AND LEFT EXPOSED AT ONE TIME IS LIMITED TO THE AMOUNT OF ACREAGE THAT THE CONTRACTOR CAN ADEQUATELY PROTECT PRIOR TO A PREDICTED RAIN EVENT. FOR LARGER SITES, GRADING SHOULD BE PHASED. IT MAY BE NECESSARY TO DEPLOY EROSION AND SEDIMENT CONTROL BMPs IN AREAS THAT ARE NOT COMPLETED, BUT ARE NOT ACTIVEZ.Y BEING WORKED BEFORE ADD!nONAL GRADING IS ALLOWED TO PROCEED. AT THE DISCRETION OF THE CITY INSPECTOR. 17. ALL DISTURBED AREAS THAT ARE NOT COMPLETED AND/OR NOT BEING ACTIVEZ.Y GRADED MUST BE FULLY PROTECTED FROM EROSION IF LEFT FOR 14 OR MORE DAYs. THE ABIUTY TO INSTALL BMP MATERIALS IN A PROMPT MANNER IS 11fH. sumCIENT. BMPs NEED TO BE INSTALLED IN THESE AREAS. 18. BMPs MUST BE STOCKPILED AT VARIOUS LOCATION THROUGHOUT THE PROJECT SITE THROUGHOUT THE YEAR. WHENEVER THERE IS A 40% CHANCE OR GREATER OF A RAIN WITHIN A THREE {3) DAY FORECAST, THE INSPECTOR WILL VERIFY THAT BMPs ARE ADEQUATELY STOCKPILED. BMPs MUST BE STOCKPILED AND READY FOR DEPLOYMENT WHEN THERE IS 50% CHANCE OF RAIN WITHIN A 48 HOUR FORECAST. FAILURE TO COMPLY WITH THIS REQUIREMENT COULD RESULT IN THE ISSUANCE OF A STOP 111'.JRK NOTICE OR OTHER ENFORCEMENT ACTION. 19. ALL TREATMENT AND EROSION CONTROL BMPs MUST BE INSPECTED WEEKLY AND PRIOR TO A FORECASTED RAIN El-£"NT OF GREATER THAN 50%, AND AFTER A RAIN El-£"NT. IN ADD!nON, TREATMENT CONTROL BMPs MUST BE SERVICED AS NEEDED THROUGHOUT THE YEAR. 20. IF SELECTED BMP FAILS DURING A RAIN EVENT, IT MUST BE REPAIRED OR IMPROl-£"0 OR REPLACED WITH AN ACCEPTABLE ALTERNATE AS SOON AS IT IS SAFE TO DO so. THE FAILURE OF A BMP IND/CA TES IT WAS NOT ADEQUATE FOR THE CIRCUMSTANCES IN WHICH IT WAS USED. REPAIRS AND REPLACEMENT MUST THEREFORE PUT A MORE ROBUST BMP MEASURE IN PLACE. 21. ALL CONSTRUCTION EMPLOYEES MUST BE TRAINED ON THE IMPORTANCE OF STORM WATER POLLUTION PREl-£"NTION AND BMP MAINTENANCE. WEATHER TRIGGERED ACTION PLAN THE DEl-£"LOPER SHALL DEPLOY STANDBY BEST MANAGEMENT PRACTICE MEASURES TO COMPLETELY PROTECT THE EXPOSED PORTIONS OF THE SITE WITHIN 48 HOURS OF A PREDICTED STORM EVENT ( A PREDICTED STORM EVENT IS DEFINED AS A FORECASTED, 40% CHANCE OF RAIN BY THE NATIONAL WEATHER SERVICE), IN ADDmON TO BMPs IMPLEMENTED YEAR-ROUND INCLUDING PERIMETER CONTROL, WIND EROSION CONTROL, TRACKING, NON-STORM WATER CONTROL, WASTE MANAGEMENT, AND MATERIALS POLLUTION CONTROL. THE NATIONAL WEATHER SERVICE FORECAST SHALL BE MONITORED AND USED BY THE DEVEZ.OPER ON A DAILY BASIS. IF PRECIPITATION IS PREDICTED ( 40% CHANCE OF RAIN), THEN THE NECESSARY WATER POLLUTION CONTROL PRACTICES SHALL BE DEPLOYED WITHIN 48 HOURS AND PRIOR TO THE ONSET OF THE PRECIPITATION. THE DEPLOYMENT OF THE BMPS SHALL INCLUDE BUT NOT BE LIMITED TO GRAVEL BAGS AND SILT FENCES. A MINIMUM OF 125% OF THE MATERIAL NEEDED TO INSTALL STANDBY BEST MANAGEMENT PRACTICES MEASURES TO PROTECT THE EXPOSED AREAS FORM EROSION AND PREl-£"NT SEDIMENT DISCHARGES MUST BE STORED ON-SITE. AREAS THAT HA l-£" ALREADY BEEN PROTECTED FROM EROSION USING PHYSICAL STABIUZA TION OR ESTABUSHED l-£"GETATION STABIUZATION BMPS AS DETERMINED BY THE CITY OF CARLSBAD ARE NOT CONSIDERED TO BE "EXPOSED" FOR THE PURPOSES OF "WEATHER TRIGGERED ACTION PLAN". AN ADEQUATE SOURCE OF EQUIPMENT AND WORKERS SHALL BE A VA/LABLE FOR DEPLOYMENT OF "WEATHER TRIGGERED BMPS~ K.· \Civil 30\1485\DWG\PGP\ 1485-PGP-04.dwg Oct 29, 2021 -11.· 12om SUBMIT A PROPOSED SCHEME TO PROVIDE IRRIGATION TO THE CITY ENGINEER. THE PROPOSAL SHALL BE SPECIFIC REGARDING THE NUMBERS, TYPE, AND COSTS OF THE ELEMENTS OF THE PROPOSED SYSTEM. 3 /RR/CATION SHALL MAINTAIN THE MOISTURE LEVEL OF THE SOIL AT THE OPTIMUM LEVEZ. FOR THE GRAD/NC OF THE HYDROSEEDED GROWTH C HYDROSEEDINC MIX SHALL CONSIST OF ALL OF THE FOLLOW/NC: 1 SEED MIX SHALL CONSIST OF NO LESS THAN: a. 20 lbs. PER ACRE OF ROSE CLOVER b. 20 lbs PER ACRE OF ZORRO FESCUE c. Jibs PER ACRE OF E SCHOOL CIA CALIFORNICA d. 4 lbs PER ACRE OF ACHILLEA MILLEFOUA e. Jibs PER ACRE OF AL YSSUM {CARPET OF SNOW) f. 1 /2 lb. PER A CR£ IF 0/MORPHOLECA g. ITEMS c. d, e, AND f OF THIS SUBSECTION MA Y BE OMITTED ON VISIBLE FROM EITHER A PUBLIC STREET OR RESIDENTIAL STRUCTURES. h. ITEM a OF THIS SUBSECTION MUST BE INOCULATED WITH A NITROGEN FIXING BACTERIA AND APPUED DRY EITHER BY DR/LUNG OR BROADCAS/NG BEFORE HYDROSEEDING. 1. ALL SEED MATERIALS SHALL BE TRANSPORTED TO THE JOBS/TE IN UNOPENED CONTAINERS WITH THE CALIFORNIA DEPARTMENT OF FOOD AND AGRICULTURE CERTIFICATION TAC ATTACHED TO, OR PRINTED ON SAID CONTAINERS. j. NON-PHYrO-TOX/C WEmNG AGENTS MAY BE ADDED TO THE HYDROSEED SLURRY AT THE DISCRETION OF THE CONTRACTOR. 2 TYPE 1 MULCH APPLIED AT THE RA TE OF NO LESS HAN 2000 lbs PER ACRE TYPE 6 MULCH {STRAW) MAY BE SUBSTITUTED, WHEN STRAW IS USED, IT MUST BE ANCHORED TO THE SLOPE BY MEGHAN/CALLY PUNCH/NC NO LESS THAN 50% IF THE STRAW INTO THE SOIL. 3 FERTILIZER CONSIST/NC OF AMMONIUM PHOSPHATE SULFATE. 16-20-0 WITH 15% SULPHUR APPUED AT THE RATE OF 500 lbs. PER ACRE. D AREAS TO BE HYDROSEEDED SHALL BE PREPARED PRIOR TO HYDROSEED/NC: 1 ROUGHEN/NC THE SURFACE TO BE PLANTED BY ANY OR A COMB/NA TION OF: a. TRACK WALK/NC SLOPES STEEPER THAN 6: 1. b. HARROW/NC AREAS 6: 1 OR FLATTER THAT ARE SUFFICIENTLY FRIABLE. 2 AREAS GRADED FLATTER THAN 6: 1 WI-IEN ANY OF THE FOLLOWING COND!nONS EXIST.· a. ADJUST/NC THE SURFACE SOIL MOISTURE TO PROVIDE A DAMP BIT NOT SA Tl/RA TED SEED BED. b. THE ADD!nON OF SOIL AMENDMENTS, PH ADJUSTMENT, LEACH/NC CO I/ER/NC SALINE SOILS TO PRO VIDEO VIABLE COND!nONS FOR GROWTH. E HYDROSEEDINC AREAS SHALL BE MAINTAINED TO PROVIDE A VIGOROUS GROWTH UNTIL THE PROJECT IS PERMANENTLY LANDSCAPED OR, FOR AREAS WHERE HYDROSEEDINC IS THE PERMANENT LANDSCAPING, UNTIL THE PROJECT IS COMPLETED AND ALL BONDS RELEASED. 2. ALL SLOPES SHALL HA VE /RR/CATION INSTALLED AND BE STABIUZED, PLANTED AND/OR HYDROSEEDED WITHIN TEN {10) DAYS OF THE TIME WHEN EACH SLOPE IS BROUGHT TO GRADE AS SHOWN ON THE APPROl-£"0 GRAD/NC PLANS. IL TO PROVIDE EFFICIENT 3. SHOULD GERM/NATION OF HYDROSEEDED SLOPES FA COVERAGE OF GRAD/NC SLOPES {90% COVERAGE) PRIOR 7i BE STABILIZED BY AN APPROPRIATE EROSION CONTROL U 0 OCTOBER 1, THE SLOPES SHALL A TT/NC MATERIAL APPROl-£"0 BY THE PUBLIC WORKS INSPECTOR. 4. LANDSCAPING SHALL BE ACCOMPUSHED ON ALL SL OPES AND PADS AS REQUIRED BY THE CITY OF CARLSBAD LANDSCAPE MANUAL, THE LANDSC OR AS DIRECTED BY THE CITY ENGINEER OF PLANNING DIR APING PLANS FOR THIS PROJECT 'ECTOR. 5. THE OWNER/APPLICANT SHALL ENSURE THAT ALL CON TRACTORS SHALL OWN ON ANY GRADING COORDINATE THE WORK OF THIS CONSTRUCTION SWPPP SH PLANS, LANDSCAPE AND /RR/GA TION PLANS, AND IMPROVEM, 'ENT PLANS AS REQUIRED FOR THIS PROJECT WORK. bliA,lnc. .s; .., 1l ~ ~i ., 5 3:: 5 1 I .s; ~ !I: 0, 0::, ., .., ., ,11 ~ ~§ (BMP) Description -2~ !3 ., "' ., 0, ec: 8e C: c:, ➔ -~ (I) & ~ -"' &l VJ-~ c::i:8 ]~ al ~ §.~ 0 0, " " :£~ ::, E " E t,::E §! 0, "" 5 c:, 0 g, -., l "" .g ., -., -c:, 0, ~ Q:: _E ~~ o,-i ~-S .S:! bi % cto ., 0, ., ] !§] 0, ts~ " " tr; .s; e .., -<: 0 ., .§ ti ] ., ::, '€l ::: t3 ·-"" ~ :.:; " e -~ § ~e .. .., " t; " :t:: -.,-...... s tr; ~a -g ~ -g 0 ., " ·s: " --·-C: ~§ C: § C: ., 0 8-"" " C: oe --<: ., ~o -0 :=: C: CIJ .!:2 } 0 ... 0 -~ e ..s e <i'.8 0 "-" bl-8 0 " ~i ~ i ~ ti ti,~ <ll (/)~ §o -8 ::E ~~ ~~ vi (]i -C: 3:: Q.. Q.. ::E "' ::E "' "' ::E :i:: ::E "' "'Q.. "' - CASQA Designation ---1 " 0::, 0, -,.., .... LC:, (0 " 0c, 0 "' -,.., r-... 0::, -"' ,.., .... LC:, (0 0::, 0) "' .... ----I I I I I I I I ~ ~ ~ ~ ~ ~ ~ J.. ~ J.. J.. ~ J.. ~ I I I I I I I!: I!: ~ ~ ~ ~ i i i i i i i i Construction Activity "' "' "' "' Gradina/Soi/ Disturbance ~ X ---~ ------Trenchin'!/Excavation >< >< " Stockoilinq ------Drilfinn '"orina Concrete/Asphalt Sawcutting ------Concrete Flatwork -"" ,.,,.... >"' ......,.. ......,.. Pavinq Conduit/Pioe Installation IX ---.,..,.. ~ ... ~ Stucco /Mortar Work ------Waste Disposal ..... ~ Staqina/l ay Down Area ------Eauioment Maintenance and Fue/inn ~ ..... -~ Hazardous Substance Use/Storaae ------Dewaterinq }II Site Access Across Dirt ->< Other Oist): Instructions: . 1. Check the box to the left of all applicable construction activity (first column) expected to occur during construction. 2. Located along the top of the BMP T(!ble is a list _of BMP's with _it's corresponding California Storm water _Q!Jality A~sociation (<;ASQA) designation number. Choose one or more BMPs you intend to use dunng construction from the 11st. Check the box where the chosen activity row intersects with the BMP column. 3. Refer to the CASQA construction handbook for information and details of the chosen BMPs and how to apply them to the project. LEGEND DESCRIPTION EC-9, FORM DIKES AND DRAINAGE SWALES SE-1, SILT FENCE SE-6, GRAVEL BAG TR-1, STABILIZED CONSTRUCTION ENTRANCE NS-9, VEHICLE AND EQUIPMENT FUELING NS-10, VEHICLE AND EQUIPMENT MAINTENANCE 11-M-1, MATERIAL DELIVERY AND STORAGE 11-M-2, MATERIAL USE 11-M-3, STOCKPILE MANAGEMENT 11-M-5, SOLID WASTE MANAGEMENT 11-M-6, HAZARDOUS WASTE MANAGEMENT 11-M-8, CONCRETE WASTE MANAGEMENT 11-M-9, SANITARY/SEPTIC WASTE MANAGEMENT NAt.lE OF PREPARER: RONAI D I HOI I OWAY QUALIFICATION OF PREPARER· osp(OSD ADDRESS: 5115 A~tl!IDA E~Cl~AS SIIIIE •1" CARI SBA□ CA 92008 SYMBOL o=c•:::> !!11111111111111~ NS-9 NS-10 11111-1 11111-2 11111-.J 11111-5 11111-6 11111-8 11111-9 QUANTITY 280 LF 330 LF 123 EA 1 EA 1 EA 1 EA 1 EA 1 EA 1 EA 1 EA 1 EA 1 EA 1 EA ~fESSio-t,~ ~RONALD L. ~ HOLLOWAY "' I NO. 29271 i * ';. OWNER'S CERTIFICATION: I UNDERSTAND AND ACKNO'MEDGE THAT I MUST.· (1) IMPLEMENT BEST MANAGEMENT PRACTICES {BMPs) DUR/NC CONSTRUCTION ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO A VOID THE MOB/LIZA TION OF POLLUTANTS SUCH AS SEDIMENT AND TO A VOID THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED POLLUTANTS; AND (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS CITY APPROVED TIER 2 CONSTRUCTION SWPPP THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETE AND SIGNED OFF BY THE CITY OF CARLSBAD. CRAIG CORRELL, MEMBER -3460 ROOSEVELT LLC OWNER{S)/ OWNER'S AGENT NAME {PRINT} OWNER(S)/ OWNER'S AGENT NAME {SICNA Tl/RE) DATE DATE land planning, civil engineering, suweylng ~ (!pfl\,~ ~ OF Ct.\.\: 5115 AVENIDA ENCINAS PHONE NO.: (760) 931-8700 SUITE "L" 1<~ l~c::: /1\ CARLSBAD, CA. 92008-4387 R.C.E. 2927! DATE INITIAL DATE INITIAL (760) 931-8700 03-31-2023 10-28-21 REVISION DESCRIPTION SJGNA~ R.C.E./CERT. NO. UC. EXP. llA TE llATE ENGINEER OF WORK OTHER APPROVAL DATE SITE ADDRESS: VACANT LOT 3460 ROOSEVELT STREET CARLSBAD, CA. 92008 AREA OF DISTURBANCE AREA OF DISTURBANCE= 3,510 S.F. (THIS AREA INCLUDES BUT IS NOT LIMITED TO OFF-SITE WORK INCLUDING PUBLIC IMPROVEMENTS AND TEMPORARY DISTURBANCE SUCH AS VEHICLE AND EQUIPMENT STAGING AREAS, CONSTRUCTION WORKER FOOT TRAFFIC, SO/UGRA VEL PILES, UTILITY TRENCHES, BACKFILL CUTS AND SLOPE KEYWAYS) CONSTRUCTION THREAT: CONSTRUCTION THREAT TO STORM WATER QUALITY (CHECK BOX): ll!I HIGH □ MEDIUM OWNER: 3460 ROOSEVELT LLC, A CALIFORNIA UM/TEO LIABILITY COMPANY 4245 SUNNYHILL ORNE CARLSBAD, CA 92008 APPLICANT: NAME: CRAIG CORRELL -3460 ROOSEVELT LLC ADDRESS: 4245 SUNNYHILL ORNE, CARLSBAD, CA 92008 TELEPHONE NO.: (760) 434-6800 EMERGENCY CONTACT: NAME: CRAIG CORRELL -3460 ROOSEVELT LLC ADDRESS: 4245 SUNNYHILL DRIVE, CARLSBAD, CA 92008 TELEPHONE NO.: (760) 434-6800 II AS BUILT" RCE EXP. DATE REVIEI.IED BY1 INSPECTOR DATE I SH4ET I CITY OF CARLSBAD I SH5TS I ENGINEERING DEPARTMENT GRADING PLANS FOR: 3460 ROOSEVELT STREET TIER 2 SWPPP GR2021-0017 COVER APPROVED: JASON S. GELDERT ENGINEERING t.lANAGER PE 63912 EXPIRES 9/30/22 DATE DWN BY: A'i. PROJECT NO. DRAWING NO. INITIAL CHKD BY: CITY APPROVAL RVWD BY: PD2021-0021 DWG 531-4A Nov. 1, 2021Craig Correll, Member DocuSign Envelope ID: 0DA00D45-3CFA-47B6-B7A7-2B9789C2D593 7/28/2022 AM 1.0' MINIMUM (TYPICAL} 2 BAGS HIGH (TYPICAL) GRADED SURFACE GRAVEL BAG SECTION (SE-6) NO SCALE . . . . . SILT FENCE -(SE-1) NO SCALE . . . . .. ~ . . .•. .. K: \Civil 30\1485\DWG\PGP\ 1485-PGP-05.dwg Nov 15, 2021 -11:41am I I I I I ) ----1-1-.IH w 4-,i,, I I I q q '1 f--L;~ ( s) +--( .) ---4.l&: • GRAVEL BAGS OVERLAP ONTO CURB RUNOFF + 7. C -s MIN. GAP BETI.IEEN BAGS ACTS AS SPILLI.IAY THREE LAYERS OF GRAVEL BAGS GRAVEL BAG DETAIL (SE-6) + s NS-9 WM-5 NS-10 m.t-1 WM-2 WM-3 WM-6 WM-8 WM-9 + s N 55"55'15"r-----.. CONSTRUCTION ENTRANCE STABILIZED (TC-1) q 10' 5' o· 1 o· 20' ------SCALE: 1" = 10' I I t : I I I I I 30' bl-lA,lnc. land planning, civil engineering. $UIVeying ;¥1)"fESS/ RONALD L. "' HOLLOWAY 5115 AVENIDA ENCINAS SUITE "L" CARLSBAD, CA. 92008-4387 (760} 931-8700 1<~l~c:: RONALD L. HOLL~£ NO. 29271 I NO. 29271 l'IVll• 10-28-21 XP. 3/31/23 ,-'---'----------------- 11 AS BUIL T11 RCE __ _ EXP. ___ _ DATE REVIEI.IED BY1 INSPECTOR DATE t==~~==t====================t==jt==t==J===i I SH5EET I CITY OF CARLSBAD I SH5EETS I 1 ENGINEERING DEPARTMENT r;G;;;R~AD~IN~G..'.::PaaiLAN~"°s=FO~R:~-:::::::::=:::::::::::::::::::::::::::::==::::::::=::::.:==:::::~ 3460 ROOSEVELT STREET GR2021-0017 PRECISE GRADING PLAN APPROVED: JASON S. GELDERT ENGINEERING MANAGER PE 63912 EXPIRES 9 30 22 DA TE 1 DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL DWN BY: AV PROJECT NO. DRAWING NO. ~~g ~~\---PD2021-0021 DWG 531-4A DocuSign Envelope ID: 0DA00D45-3CFA-47B6-B7A7-2B9789C2D593 7/28/2022