Loading...
HomeMy WebLinkAbout2459 OCEAN ST; A; PC2020-0016; PermitPERMIT REPORT Print Date: 03/31/2022 Job Address: Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: 2459 OCEAN ST, # A, BLDG-Plan Check 2030210201 $0.00 Project Title: VILLA MIRA ALA COSTA Plan Check Permit CARLSBAD, CA 92008-2273 Work Class: Track#: Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Residential DEV2020-0050 Description: VILLA MIRA ALA COSTA: REMODEL AND ADDITION TO MULTIPLE UNITS Applicant: SPACES RENEWED JON PRICE 1107 S COAST HWY OCEANSIDE, CA 92054 (760) 390-0067 FEE Total Fees: Property Owner: GRANT TIMOTHY L NANNETTE L 8907 E RAI NTREE DR, # 140 SCOTTSDALE, AZ 85260 Total Payments To Date: (_ City of Carlsbad Status: Permit No: PC2020-0016 Closed -Finaled Applied: 05/05/2020 Issued: 07/10/2020 Finaled Close Out: 03/31/2022 Inspector: Final Inspection: Contractor: REMODEL SOLUTIONS 1107 S COAST HWY OCEANSIDE, CA 92054-5101 (760) 637-2175 Balance Due: AMOUNT 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov (_ City of Carlsbad Job Address 2459 Ocean Street RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Suite: A, B, & C Plan Check ffi.2020-ro I l.p Est. Value PC Deposit --------- Date ___,5..,__-.,.5,,._-_.2._1._°J,__ __ APN: 203-021-02-01. 203.021-02-02. 203-021-02-03 CT/Project#: __________________ Lot#: ___ _ Fire Sprinklers: 0YES 0 NO Air Conditioning: 0YES ONO Electrical Panel Upgrade:0 YES0 NO BRIEF DESCRIPTION OF WORK: Multifamily renovation with small additions to 2 units. [Z] Addition/New: 237 Living SF, 237 Deck SF, ___ Patio SF, ____ Garage SF Is this to create an Accessory Dwelling Unit? 0 Y 0 N New Fireplace? 0 Y 0 N, if yes how many? __ [Z]Remodel: 65"0 SF of affected area Is the area a conversion or change of use? 0 Y 0 N 0 Pool/Spa: ____ SF Additional Gas or Electrical Features? ------------- □solar: ___ KW, ___ Modules, Mounted:0Roof0Ground, Tilt:O YON, RMA: OYON, Battery:OY ON, Panel Upgrade: OY ON 0 Reroof: New roofing throughout to include standing seam on sloped areas and TPO Class 'A' at flat sections. @Plumbing/Mechanical/Electrical Only: ~#Z~~'?<~C..~,~~g.=£=f:M1$~----------------- D Other: ________________________________ _ APPLICANT (PRIMARY CONTACT) Name: Spaces Renewed (Jon Price) Address: 1107 S Coast Hwy City: Oceanside state:_C_A __ .Zip: 92054 Phone: 760-390-0067 Email: jon@spacesrenewed.com DESIGN PROFESSIONAL Name: Spaces Renewed (Jon Price) Address: 1107 S Coast Hwy City: Oceanside State: CA Zip: 92054 Phone: 760-390-0067 Email: jon@spacesrenewed.com Architect State License: ___________ _ PROPERTY OWNER Name: Mimi Sayer (President HOA) Address: 2459 Ocean St Unit B City: Carlsbad State: CA Zip: _9_2_0_08 __ _ Phone: f,C,t 'G'f;;-J,-44-?. Email: (/(/1,n, sayee@Jv,,1gi/. CQ4¥l CONTRACTOR BUSINESS Name: Spaces Renewed (Jon Price) Address: 1107 S Coast Hwy City: Oceanside state:_C_A __ Zip: 92054 Phone: 760-390-0067 Email: jon@spacesrenewed.com State License: GCL# 931687 Bus. License: BLOS123690 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov 8-1 Page 1 of 2 Rev. 03/20 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the labor Code, for the performance of the work which this permit is issued. [Z] I have and will maintain worker's compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: _F_A_L_LS_LA_K_E_F_IR_E_&_CA_s_u_A_L_TY_c_o ___________ _ Policy No. FLAooaa2so1 Expiration Date: _o_,_10_11_20_2_1 _______ _ D Certificate of Exemption: J certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for In Section 3706 of the Labor Code, ;nterest and attorney's fees. ~ CONTRACTOR SIGNATURE: ---~....,.___,,_,..._ ____________ □AGENT DATE: _s,_112_02_0 ___ _ ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License law for the following reason: 0 r, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. lf, however, the building or improvement is sold within one year of completion, the owner-bu·11der will have the burden of proving that he did not build or improve for the purpose of sale), [Z] !, as owner of the property, am exclusively contracting with lkensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License law). 0 I am exempt under Section ________ ,Business and Professions Code for th·1s reason: 1. 1 personally plan to provide the major labor and materials for construction of the proposed property improvement. OYES Q NO 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. r have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but 1 have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): ::::~:::;,:· ~J;•:'~-•""'""~-... ~,-:·::···~~=~~: .. , ... _,., CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: NONE lender's Address: _____________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevenf1on program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? I Yes/ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes/ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes/ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over S'O' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 360 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days {AB 291 APPLICANT SIGNATURE: 1635 Faraday Ave Carlsbad, CA 92 B-1 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of2 Email: Building@carlsbadca.gov Rev. 03/20 DATE: June 24, 2020 JURISDICTION: CARLSBAD PLAN CHECK#.: CBPC2020-0016 ✓• EsG1I SET II PROJECT ADDRESS: 2459 OCEAN STREET ~PLICANT r JuRIS. PROJECT NAME: APARTMENT REMODEL FOR SAYER( PRESIDENT HOA) ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted:h/)IJ.(ll/)..by~ Email: Mail Telephone Fax In Person 0 REMARKS: By: Abe Doliente (for BD) EsGil 6/16/20 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 CARLSBAD CBPC2020-0016 June 24, 2020 DATE: 5/15/2020 JURISDICTION: CARLSBAD PLAN CHECK#.: CBPC2020-0016 ✓• EsG1I SETI PROJECT ADDRESS: 2459 OCEAN STREET □ APPLICANT □ JURIS. PROJECT NAME: APARTMENT REMODEL FOR SAYER( PRESIDENT HOA) D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [2J The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [2J The applicant's copy of the check list has been sent to: JON PRICE D EsGil staff did not advise the applicant that the plan check has been completed. [2] EsGil staff did advise the applicant that the plan check has been completed. Person contacted: JON Telephone#: 760 390 0067 Date contacted: (by: ) Email: JON@SPACESRENEWED.COM Mail Telephone 0 REMARKS: By: Bert Domingo EsGil Fax In Person Enclosures: 5/07/2020 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 CARLSBAD CBPC2020-0016 5/15/2020 CARLSBAD CBPC2020-0016 5/15/2020 PLAN REVIEW CORRECTION LIST COMMERCIAL PLAN CHECK#.: CBPC2020-0016 OCCUPANCY: R 2 TYPE OF CONSTRUCTION: VB ALLOWABLE FLOOR AREA: SPRINKLERS?: REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 5/15/2020 FOREWORD (PLEASE READ): JURISDICTION: CARLSBAD USE: APARTMENT ACTUAL AREA: STORIES: HEIGHT: OCCUPANT LOAD: DATE PLANS RECEIVED BY ESGIL CORPORATION: 5/07/2020 PLAN REVIEWER: Bert Domingo This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2019 CBC, which adopts the 2018 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2018 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. CARLSBAD CBPC2020-0016 5/15/2020 GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. PLANS 2. All sheets of the plans and the first sheet of the calculations are required to be signed by the licensed architect or engineer responsible for the plan preparation. California State Law. 3. Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: • Occupancy Classification(s) • Description of Use ♦ Type of Construction • Sprinklers: Yes or No • Stories ♦ Height • Floor Area • Occupant Load • Justification to exceed allowable area in Table 506.2 (if applicable) • Justification to exceed allowable height or stories in Tables 504.3/504.4 (if applicable) CARLSBAD CBPC2020-0016 5/15/2020 ♦ On the cover sheet of the plans, specify any items that will have a deferred submittal (trusses, fire sprinklers/alarms, etc.). Additionally, provide the following note on the plans, per Sec. 107.3.4.1: "Submittal documents for deferred submittal items shall be submitted to the registered design professional in responsible charge, who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and that they have been found to be in general conformance with the design of the building. The deferred submittal items shall NOT be installed until their design and submittal documents have been approved by the building official." INTERIOR WALL AND CEILING FINISHES 4. Provide a note on the plans or on the finish schedule, stating, "Wall and ceiling materials shall not exceed the flame spread classifications in IBC Table 803.13." GLASS AND GLAZING 5. Specify on the window schedule the glass type and thickness to show compliance with Section 2404. 6. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.4 (see exceptions): a) Fixed and openable panels of door assemblies. b) Fixed or operable panels adjacent to a door where the nearest vertical edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. ROOFS/DECKS/BALCONIES 7. Specify roof slope on the plans. 8. Specify on the plans the following information for the roof materials, per Section 1506.3: a) Manufacturer's name and product name/number. b) ICC approval number, or equal. CARLSBAD CBPC2020-0016 5/15/2020 9. Provide skylight details to show compliance with Sections 2606.5 and 2404, or specify on the plans the following information for the skylight(s): a) Manufacturer's name and Model name/number. b) ICC approval number, or equal. 10. Show the required attic ventilation on the plans. Show "area required" and "area provided." The net free ventilating area shall not be less than 11150th of the area of the space ventilated. Section 1202.2. PLUMBING 11. Per California law, additions or alternations of Commercial projects or Multifamily Residential projects (condos, apartments and hotels with kitchens) available for use before January 1, 1994 may require replacement of noncompliant plumbing fixtures *** by water conserving fixtures: Please note on the plans the specific plumbing fixtures requiring replacement. *** "Noncompliant plumbing fixtures" are any of the following: • Any water closet exceeding 1 .6 gallons/flush. • Any urinal manufactured to use more than 1.0 gallon/flush. • Any showerhead exceeding 2.5 gallon/minute. • Any interior faucet that emits more than a 2.2 gallons/minute. • Hot water piping is required to be insulated as follows: 1" pipe size or less: 1" thick insulation, larger pipe sizes require 1 ½" thick insulation. See Table 120.3-A. • Instantaneous water heaters (rating greater than 2 kW) shall have isolation valves and hose bibs installed on both the cold water supply and hot water supply piping. ES 110.3 FIRE PROTECTION 1. In existing buildings, when alterations, repairs or additions requiring a permit occur (or when one or more sleepin9 rooms are aaEleEI), the dwelling unit shall be provided with smoke alarms located as required for new dwellings; the smoke alarms shall be interconnected and hard wired. Exception: Smoke alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R314.2.2. CARLSBAD CBPC2020-0016 5/15/2020 2. When alterations, repairs or additions are proposed for dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages), the dwelling unit shall be provided with carbon monoxide alarms located as required for new dwellings; the carbon monoxide alarms shall be interconnected and hard wired. Exception: Carbon monoxide alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R315.2. ADDITIONAL 12. Shower enclosures shall be safety glass. 13. Please show on the sections the recommended insulation of the roofs, the walls and the floors. 14. Show a self-closing and self-latching door or an automatic-closing and latching door; either 1-3/8" solid core or a listed 20-minute assembly, for openings between garage and dwelling. Section R302.5.1. 15. RR 1 recommended 2X10@ 16' oc. But the framing plan shows different. 16. Please show grid lines on the structural plans. To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes. please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: □ Yes □ No The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bert Domingo at Esgil. Thank you. CARLSBAD CBPC2020-0016 5/15/2020 CARLSBAD CBPC2020-0016 5/15/2020 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: CARLSBAD PREPARED BY: Bert Domingo PLAN CHECK#.: CBPC2020-0016 DATE: 5/15/2020 BUILDING ADDRESS: 2459 OCEAN STREET BUILDING OCCUPANCY: R 2 BUILDING I AREA I Valuation Reg. VALUE ($) PORTION (Sq.Ft.) Multiplier Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code CB By Ordinance 1997 UBC Buildin Permit Fee • 1997 UBC Plan Check Fee • Type of Review: D Complete Review 0 Repetitive Fee • Repeats • Based on hourly rate 0 OIiier [,] Hourly &Gil Fee Mod. 0 Structural Only 41 Hrs.@• :====s=1=05=-=oo: Comments: In addition to the above fee, an additional fee of$ $ /hr.) for the CalGreen review. $420.ooj is due ( hour@ Sheet 1 of 1 PCSO Engineering Corp 3529 Coastview Court Carlsbad, CA 92010 Ph: 760-207-1885 Structural Design Calculations Residential Remodel Client Spaces Renewed 1107 South Coast Highway Ocenaside, CA 92054 Project Dominic Residence 2461 Ocean Street, Unit C Carlsbad ..... QA -B~Q08 .. - ·' ' , ' \ 17f '1/-z.J --.1 Paul S. GhristenSbn RCE C57182, exp. 12/31/17 February 28, 2020 PCSD File #: 19-525.1 f'A-1,tL .:.-hr-i.jtU•>D» S A-H Pi.uoo J;. ... ,, ... =r-i»' ..-o ON NO ON ... -N~ 01.[) (Y) 0 N CD ..,.. 0 0 I 0 N 0 N 0 ti. Paul Christenson San Diego Engineering 3529 Coastview Ct -Carlsbad, CA 92010 Telephone (760) 207-1885 -Email: paul.pcsd@gmail.com 1.0 Design Criteria: Dominic Residence 19-525.1 Code: Timber: 2019 California Building Code -ASCE 7-16 Douglas Fir-Larch (DF-L), WWPA or WCLIB 2x Wall Framing: DF-L #2 (unless noted otherwise) 2x Rafters & Joists: DF-L #2 " " Posts & Beams: OF-L #1 ~ fl Glue-Lam Beams: Simple Span: Grade 24F-V4 (OF/OF) Grade 24F-VB (DF/DF) Cantilevers: Sheathing: Min. APA-Rated Sheathing, Exposure 1, Plywood or OSB (U.N.O.) Engineered Framing Wood I-Joists: TJI 110,210,230,360,560 ICC ESR-1153 1.9E Microllam, 2.0E Parallam ICBO ER-4979 Concrete: Concrete Block: Mortar: Grout: LVL, PSL Compressive Strength @ 28 days per ASTM C39-96: Footings: f c = 2500 psi Grade Beams: f c = 3000 psi Grade N-1 per ASTM C90-95, fm = 1500 psi per ASTM E447-92 Type S Mortar Cement per ASTM C270-95, Min. f'm = 1800 psi @ 28 days. Coarse Grout w/ 3/8" Max. Aggregate per ASTM C476-91 , Min. f'm = 2000 psi @ 28 days. Reinforcing Steel: #4 & Larger: #3 & Smaller: ASTM A615-60 (Fy = 60 ksi) ASTM A615-40 (Fy = 40 ksi) Structural Steel: 'W' Shapes: ASTM A992, Fy= 50-65 ksi Plates, Angles, Channels ASTM A36, Fy = 36 ksi Tube Shapes: ASTM AS00, Grade 8 , Fy= 46 ksi Pipe Shapes: ASTM A53, Grade B, Fy=35 ksi Welding Electrodes: Structural Steel: E70-T6 E90 Series Bolts: Soils: References: A615-60 Rebar: Sill Plate Anchor Botls & Threaded Rods: Steel Moment & Braced Frames: 1500 psf Bearing Pressure A307 Quality Minimum A325 (Bearing, U.N.O.) JOB 19-525.1 SHEET NO 2... OF ? ,u/r;",t,lne,t,Oh ~lh 2/zeJO bJUIHTVIJ ----,,..,,,..,,..,,,..,- CALCULATED BY PSC DATE 2/28/20 CHECK BY _____ DATE __ _ 3529 Coastview Ct -Carlsbad, CA 92010 SCALE Telephone (760) 207-1885 -Email: paul.pcsd@gmail.com 2.0 LOAD LIST 2.1 Roof (Vaulted) Roofing 15/32" Sheathing Roof Framing 5/8" Gyp. Bd. Insulation and Misc. IoL = ILL = Total Load= 2.2 Roof (w/ ceiling) Roofing 15/32" Sheathing Roof Framing Insulation and Misc. 2.3 Ceiling Ceiling Joists IoL = ILL = Total Load= 5/8" Gyp. Bd. Insulation and Misc. 2.4 Walls IoL = _ILL = Total Load= Exterior Wall 7/8" Stucco 15/32" Sheathing 2x4 Studs @ 16" o.c. 5/8" Gypsum Bd. Misc. 6.0 psf 1.5 psf 2.8 psf 2.8 psf 1.9 psf 15.0 psf 20.0 psf 35.0 psf 6.0 psf 1.5 psf 2.8 psf 1.7 psf 12.0 psf 20.0 psf 32.0 psf 1.3 psf 2.8 psf 1.9 psf 6.0 psf 10.0 psf 16.0 psf 9.0 psf 1.5 psf 1.1 psf 2.8 psf 0.6 psf 15.0 psf Interior Wall 1/2" Gyp. Bd. (2 Sides) 2x4 Studs @ 16" o.c. Misc. 4.6 psf 1.1 psf 2.3 psf 8.0 psf ? ,u/f;,("n:nen.ron 'ef 1.11 ,tf"1fo £t.fV'eennJ 3529 Coastview Ct -Carlsbad, CA 92010 JOB SHEET NO CALCULATED BY CHECK BY SCALE 19-525.1 ?I OF PSC DATE 2/28/20 DATE Telephone (760) 207-1885 -Email: paul.pcsd@gmail.com 2.0 LOAD LIST (CONTINl 2.5 Floor Floor Cover Sheathing 2x F.J. 5/8" Gyp. Bd. Insulation and Misc. I oL = I LL = Total Load= 5.5 psf 2.3 psf 3. I psf 2.8 psf 1.3 psf 15.0 psf 40.0 psf 55.0 psf (60.0 psf -Decks) WIND PARAMETERS 2.6 Wind Basic Wind Speed = 110 mph Exposure Cat = D Ps = >.Kzrl*Ps30 (ASCE 7 • Equation 6-1 ) P = 41.23 psf P = 24. 7 psf (•0.6 -ASD) 2.7 Seismic SMs = 1.166 Sos= (2/3) SMs Sos= 0.777 _ Sos Cs -(R/I) Cs = 0.12 USE: V= 0.120 WoL ASD BASE SHEAR V ASo= 0.085 WoL (I 1.4-3) >-= 1.55 (fig. 6-3) Ps30 = 26.6 psf Kzt = 1.00 (fig. 6-4) I = 1.0 USGS APP LI CA TJON S,= 1.1 S1= 0.397 F1 = 1.06 R = 6.5 h" = 40.00 Occupancy Category: Site Class: Fv= 0.00 I = 1.00 2 D SEISMIC DESIGN CATEGORY S1 <o.1s S1 > o.04 Ss > o.u (11.6 ASCE 7-05) (1 I .4.1 ASCE 7-05) (fig. 6-3) (table 11.5-1) T.=c 1 •(h,.)°-75 = 0.318 Ts= Soi/Sos -0 k= 1.0 :'.qn. 12.8-1 Not 01 Ta<0.5 Seismic Design Category: D u.s. Seismic Design Maps A OSHPD Grant /Dr»+1 ~ tc 2459 Ocean St, Carlsbad, CA 920081 USA Latitude, Longitude: 33.1633481, -117.357562 O..ign Code Reference Document Risk Category Site Cius :Type ! Ss . S1 . S1.45 . SM1 Type soc Fa ; Fv PGA FpGA :p~ ! TL 'SsRT SsUH 'SsD · S1RT · S1UH ' i S1D : PGAd ; CRS I Value 1.1 0.397 1.166 null -See Section 11.4.8 0.777 null -See Section 11.4.8 ....... -·-----..-·. Value null -See Section 11.4.8 1.06 null -See Section 11 .4.8 0.487 1.113 0.5-42 8 1.1 1.233 f.5 0.397 0.439 0.6 0.611 0.893 :\ttps://&ei$mianaps.org -0 ~ co -0 ' (0 ..0 (/J .:: n, (..) OArmyand ·Y Navy Ac~demy 1/10/2020, 2:42:14 PM ASCE7-16 II D • Stiff Soil O..erlptlon MCER ground motion. (for 0.2 second period) Oesetiption MCER ground motion. (for 1.0s period) Site-modified spectral acceleratlon value SibHT!odifled spectral acceleration value Numeric seismic dssJgn value at 0.2 second SA Numeric seismic design value at 1.0 second SA Seismic design category Site ampllflcadon factor at 0.2 second Site amplification factor at 1.0 second MCEG peak ground acceleration Site amplification factor at PGA Site modified peak ground acceleration Long-period transition period in seconds Probabilistic risk-targeted ground motion. (0.2 second) Factored uniform-hazard (2% probability of exceedance in 50 y1N11S) spectnrl acceleration Factored determfnl11tlc acceleration value. {0.2 second) Probabilistic risk-targeted ground motion. (1.0 second) Factored uniform-hazard (2% probabillty of exceedance In 50 years) spectral acceleration. Factored deterministic acceleration value. (1.0 second) Factored detennlnlstic acceleration value. (Peak Ground Acceleration) Mapped value of the risk coefficient at short periods Map data @2020 + 0 II] MEMBER REPORT Floor Framing, (FB-1) Fir Bm 1 plece(s) 4 x 12 Douglas Fir-Larch No. 2 Overall Length: 5' 11 • PASSED '11 + 0 ~ All locations are measured from the outside race of left support (or lelt cantilever end). All dimensions are horizontal. -' , ~. \; )'!'.1~i~!;~~' •".:;,~.~-·~,r f~J,i'AlcMil ,,V Member Reaction (lbs) 1893 C, 2" 7656 (3.50") Shear (lbs) 1050 Cl 1' 2 3/4" 4725 Moment (R-lbs) 2365 @ 2' 111/2" 6091 Uve Load Def!. (in) 0.010 @ 2' 11 1/2' 0.186 Total Load Def!. (In) 0.1>'21 @ '2' 11 1/2" ll.'279 • Oetlectlcn crltl!fla: U (L/360) and TL (l/240). ._. ):V~.lf:4-i::· r;J.tif~ Passed (25%) - Passed (22%) 1.00 Passed (39%) 1.00 Passed (L/999+) - 'Passed (L/999+) - 'Uiiiidl, c:. .... ,.:~~ ~;f);'f;i:.~'i!'.-~., 1.0 D + 0.75 L + 0.75 Lr (All Spans) 1.0 D + 1.0 L (All Spans) 1.0 D + 1.0 l (All Spans) 1.0 D + 0.75 L + 0.75 Lr (All Spans) 1.ll 'D + ll.75 L + 0.75 Lr (All Spans) System : Floor Member Type : Drop Beam Building Use : Residential 8uildi"I/ Cod<! : IIIC 2018 Design Methodology : ASO • Top Edge Bracing (Lu): Top cxxnpressfon edoe must be braced at S' 11' o/c based on loads applied, 111less detailed otherwise. • Bottom Edge Bracing (Lu): Bottom compression edge must be braced at S' 11' o/c based on loads applied, unless detailed otherwise. • Applbble calculatlons are based on NOS. 2189 BIOCl<lng Wevet,aeuser warrants that the slZlng of its products witt be In accordance with Weyemaeuser product design criteria and pulilished design values. Weyerhaeuser e,cp,essly disclaims any other warranties related IX> the soltwllre. Use of this software Is not Intended to drcumvent the need for • design professional as determined by the authority having jurisdiction. The designer of record, builder or framer Is responsible to assure that this calculatlon Is a,mpatjble with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manut'actun,d at Weyerhaeuser faclltles are third-party cettlfled to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evatuatlon reports ESR-1153 and ESR-1387 and/or tested In accordance with applicable ASTM standards, For current code evauation reports, Weyerhaeuser product Pterature and lnstaRation details ref-er to www.weyerhaeuser.com/woodproduct:s/document-library. The product application, Input design loads, dimensions and support Information have been provided by ForteWES Soltware Operator ,_WEIi Software <>s,en,tor .JobNota Paul 0,rlstenson PCS0 Engineering (760) 207-1885 peul .~C!>gmall,com Weytrhaaiscr 2/11/2020 12:05:24 AM UTC ForteWEB v2.3, Engine: VS.0.0.21, Data: V7.3.2.0 File Name: Dominic Page 1 / 1 0 [TI MEMBER REPORT Aoor Framfng, (FB-2) Fir Sm 1 plece(s) 3 1/r x 11 7 /8" 2.0E Parallam® PSL All locatlons are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. -_ _, ...:. ·-""'. ~~i ., ~ [l!Ud•f•~·..,_,., ~--a.~_,:i;" ~,. " -~ •(P'~ 1-W!d: '. ·--~){"' ~w.;- Member Reaction (lbs) ◄713 Ci 2• 7656 (3.50") Passed (62%) -1.0 D + 0.75 L + 0.75 Lr (All Spans} Shear (lbs) 3532 @ 1' 3 3/8" 8035 Passed ( 44%) 1.00 1.0 D + 1.0 L (All Spans) Moment (R·lbs) 13013@6' 2· 19902 Passed (65%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Deft (In) 0.196@ 6' 2" 0.-400 Passed (lJ735} .. 1.0 D + 0.75 L + 0.75 Lr (All Spans) Total Load 'Defl. (in} "0.◄'03@"6''2" MOO Passed (l./3'S7) -1.0 D + 0:7!i L + 0.75 Lr (All Spans) • Denectlon crtterla: LL (L/360) and n (IJ240). • Top Edge Bradng (Lu): Top compression @dge must be braced at 12' 4" o/c based on loads applied, unless detailed otherwise. • Bottom Edge lndng (Lu): Bottom compression edge must be braced at 12' 4° o/c based on loads applied, unless detailed otherwise. • Bloddng Panels are assumed to C1lff'( no loads applied dk'ectly above them Ind the rua load Is applied to the member being designed. I • Unlrorm (Pl.Fl PASSED <I + 0 System : Floor Member Type : Drop Beam Building Use : ResJdentlal 8u/ldir,g Code : IBC 2018 Design Methodology : AS0 Weyerhaeuser wamints that the sizing of Its products Will be In 1ccordance with Weyertileuser product design crfter11 and pubAshed design values. Weyerhaeuser elepfessly disclaims any o!tler warranties related to the software. Use of this software Is not Intended to draimvent the need for a design profession.al as determined by the authority having Jur1sdlctlon. The designer of record, builder or framer Is responsible to assure that this c,lculatlon Is compatible with the overall project. Accessories (Rlm Board, Bloddng Panels and Squash Blocks) are not designed by this software. Products m,nufactured at Wevem-iser ™=1ltles are third-party certffied to sustainable forestJy standards, Weyerhaeuser Englnee<ed Lumber Products have been evaluated by ICC-ES under evaluatlon reports ESR-1153 and ESR-1387 ard/or tr:sted In accordance with applicable ASTM standards. For current code evaluation reports, Wevem,euser product literature llnd Installation deQfls refer to www.weyerhaeuser.com/WoOdproducts/document-flbrary. The product appUca~on, input design loads, dlmensJons and support infonna~on have been provided by ForteWEB Sortware Operator ForteW!B SoftwaN Operator JobN- Paul Ovtstenson PCSD Engineering (760) 207-1885 A paul.padOgmall.com ~ 2/11/2020 12:13:05 AM UTC ForteWEB v2.3, Engine: va.0.0.21, Data: V7.3.2.0 File Name: Dominic Page 1 / 1 + 0 MEMBER REPORT Floor Framing, (FB-3) Fir Bm 1 plece(s) 7" x 16" 2.0E Parallam® PSL Overall Length: 20' s• All locations are measured fTom the outside face of left support (or left cantilever end). All dlmenslons are horizontal. -' ' . .:.:::Jt'';{4' ff· .. :~·.-~~,.~-r ~~.t-:~~ •.i~.; ........ ~~,.t~~~~---'d'"''f -1"• .. · ~)i~l1!~\~k4l~ -Member Reaction (lbs) 12729 !IP 20' 3" 15313 (3.50") Passed (83%) -1.0 D + 1.0 L (All Spans) Shear (lbs) 11743@ 18' 9 1/2" 21653 Passed (54%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs) 46017 (fl 12' 5 3/4" 69909 Passed (66%) 1.00 1.0 D + 1.0 L (All Spans) Uve Load Dell. (in) 0.431 (I!) 10' 5 1/4" 0.669 Passed (L/559) -1.0 D + 1.0 L (All Spans) Total Load Oefl. (In) 0.755 (I!) 10' 7 13/16' 1.004 Passed (L/319) --1.0 D + 1.0 L (All Spans) • Oeftectlon a1tena: LL (l/360) and Tl (l/2~0), , Top Edge l!rlldng (Lu): Top compression edge must be bnlced at 20' s• o/c based on loads applied, unless detailed otherwise. • Bottom Edge Bnldng (Lu): Bottom compression edge must be braad at 20' s• o/c based on loads applied, unless detailed otherwise. • Member stiould be sld!!-loaded from both sides of the member or braad to prevent rotation. 2 • Cbtlimn • OF 3.50" 2.91' 1045 13775 !!b:klng • Bloddng Panels are assumed to carry no loads applied directly above them and !he fun load Is applied to the member being designed. PASSED "l + 0 System : Floor Member Type : Drop Beam Bufldlng Use : Resldentlal l!lul\c!l,ng Cede : lit 1018 Design Methodology : ASO Wev,,rtiaeuser warrants that !he slZing of Its products w!U be In accordance with Weyerl,aeuser product deslgn criteria and pubtished design values. Weyerhaeuser expressly disclaims any other warranties relall!d to !he scftware. Use of this scftware Is not lntl!flded to drOJmllfflt !he need for a design professlonal a. detennlned by !he llllthonty haw,g Jurlsdlcllon. The designer of recon!, bulkSer or ,,.,,mer Is responslbl• to assur• that this calculatlon Is oompattble with the ovoran project Accassories (Rim Board, Bloddng Panels and Squash Blocks) are not designed by this sol!watt. Products manufactured at Weyerhaeuser t'adtltles are third-party Cl!rtlfled to sustainable forestry stlndards. Weyemaeuser Engineered Lumber Products hav• been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested In accordance with appllcabl• ASTM standards. For current cod• evaluation reports, Weyerhaeuser product Ht•rature and lnstallatlon details refer to www.weyerhaeuser .a:,m/woodproducts/document-llbrary. The product applicatlon, Input deslgn loads, dimensions and support Information have been provided by ForteW£8 Software Operator PomiWEI Software Operator Job Notes Paul 0111stenson PCSO Engineering (760) 207-1885 A l)IIUl.pcsd@lgmall,oom ~str 2/11/2020 12:14:48 AM UTC ForteWEB v2.3, Engine: VS.0.0.21, Data: V7.3.2.0 File Name: Dominic Pagel /1 MEMBER REPORT Floor Framing, (FB-4) Fir Bm 1 piece(s) 7" x 11 7/8" 2.0E Parallam® PSL Overali Length: 20' 6" 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. .~'IIIMwl!a :1 <;;_t~ ·'2:1 l~{.,,~ •. ~1\,., ,·1.;;,~.ii'~, ~!~ tf;/4~ · ,·•.:( ;~ ,;,j&ft --f,;111 b......,.~l~ '·,Y,,if., · ' Member Reaction (lbs} 4823@ 20' 4' 15313 (3.50") Passed (31 %} -1.0 D + 0.75 L + 0.75 Lr (All Spans) Shear (lbs) 4319@ 19' 2 5/8" 16071 Passed (27%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs) 24528 @ 13' 7• 39805 Passed ( 62%) 1.00 1.0 D + 1.0 L (All Spans) Uve Load Deft (in) 0.252 @ 10' 11 5/16" 0.672 Passed (L/962) -1.0 D + 0.75 L + 0.75 Lr (All Spans) Total Load Deft. (in) 0.802 @ 10' 1115/16" 1.008 Passed (L/302) .. 1.0 D + 0.75 L + 0.75 Lr (All Spans) • Oeftectlon criteria: U. (L/360) and TL (L/240). • Top Edge ll<adng (Lu): Top oompresslon edge must be braced at 2<1 6" o/c based on loads applied, i,iless detailed othe!wise. • Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 20' 6" o/c based on loads applied, unless detailed otherwise, • Member should be side-loaded from both sides of the member or braced to prevent rota~on. 1 • COiumn • Of 3.50" 1.50" 1592 828 212 2632 BIOddng 2 -COiumn • OF 3.50' 3.50" I.SO' 3337 1406 575 5318 Blod<lng • Bloddng Panels are assumed to carry no loads applied directly a~ them and the full load Is applied to the member being designed. 0 -Self Weight (PLF) 0 to 20' 6' N/A 26.0 -- 1 • Uniform (PLF) o to 13' r (l'ront,) N/A 20.0 40.0 Default Load 2 • Point (lb) 13' 7' (Front) N/A 1369 580 252 3 • Uniform (Plf) 13' 7" to 16' 10' (Front) N/A 185.0 40.0 20.0 Default Load 4-Unlfonn(PLF) 16' 10' to 20' 6' (Front) N/A 205.0 100.0 50.0 Default Load 5 • Point (lb) 13' r (Front) N/A 1402 61◄ 286 w ' .. )t ·'!:,'{;:~~ .• fff;;!:}; PASSED 0 System : Floor Member Type : Drop Beam Building Use : Residential 8uildlng Code : IBC 2018 Design Methodology : ASO Weyerhaeuser warrants that the sizing of its products wlll be In acconlanu with Weyerhaeuser prOduct design alteJ1a and pubished dl!Sign values. W~ expressly disclaims any Olher warranties l1!lated to the software. Use of this software Is not Intended to drcumvent the need for a design professional as detfflnlned by the authority having jur1sdlctlon, The designer of record, builder or framer Is responsible to assure that this calcula~on is compatible with the overall project. Accessories (Rim Board, Blodclng Panels and Squash Blocks) are not dl!Signed by this soltware. Products manufacrured at Wey-l'adllt1es .,., third-party cerU1led to suslalnable forewy stacidard•. Weveri\aelJ ... Engl-..d ~ Prod/Jas nav" bun "valuated by lCC,ES under e,alualk)n ~ ESR-1153 and ESR-1387 and/or ~ In aca,roance with applicable ASTM standards. For current code evaluatton reports, W~aeuser product Utorature and Installation details refer to www.wevemaeuser.com/WOOdproductdocument-llbrary. The product application, Input design loads, dimensions and support Information have been provided by ForteWEB Software Operator forteWEI Software Operator Job Notes Paul Christenson PCSO Engineering (760) 207-1885 A paul.pcsdOg1n11ll.com 2/11/2020 12:23:33 AM UTC ForteWEB v2.3, Engine: VS.0.0.21, Data: V7.3.2.0 File Name: Dominic Pagel / l + 0 MEMBER REPORT Floor Framing, (FB-5) Fir Bm 1 piece(s) 5 1/4" x 9 1/2" 2.0E Parallam® PSL Overall Length: 5' 11 • -. -· .. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. ~--.... ?:!,~Ii.'~~-ti ,i~•~•~.t·,· ·,:~.~ ... ;", ':•~·-' r ,:, ·'.'1 ~ LW;~·~;,~ ,. Member Reaction (lbs) 9691@ 2" 11484 (3.50") Passed (84%) .. 1.0 D + 1.0 L (All Spans) Shear (lbs) 9284@ 1' 1" 9643 Passed (96%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft·lbs) 17020@2' 19585 Passed (87%) 1.00 1.0 D + 1.0 L (All Spans) Uve Load Defl. (In) o.on @ 2· 9 5/16" 0.186 Passed (L/933) -1.0 D + 1.0 L (All Spans) Total Load 'Defl. (In) 0.134@2'97/16" 0.279 Passed (L/501) -1.0 !l + 1.0 L (All Spans) • Detlt!Clion crtterta: U. (l/360) and TL (l/240), • Top Edge Bracing (Lu): Top compression edge must be braced at 5' 11 • o/c based on loads applied, unless detailed otherwise. • Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 5' 11' o/c based on loads applied, unless detailed otherwise . .. !r .'i• ... • 2 -Column -OF 3.50" 3.50' 1.62' 2658 2647 472 5777 , Bloddng Panels are assu~ to carry no loads applied directly abolle them and tile f\JII load Is applied to tile member being designed. 1 • Unifo,m (Plf) 50.0 Defautl Load 2 • Point (lb) 8516 ~~:•~~ PASSED g/ + 0 System : Floor Member Type : Drop Beam Building Use : Resldential Building Code : I9C 2018 Design Methodology : ASD Weyerhaeuser warrants that the si21ng of Its products will be In accordance with Weyerhaeuser product design criteria and published design values. W~ expressly disclaims any other warranties related to the soltware. Use of this software Is not Intended to circumvent the need for a design professional as determined by the authority having Jurisdiction. The designer of record, builder or mimer Is responsible to assure that this cak:ulatlon Is compattble with the overall project. Accessories (Rim Board, Bloddng Panels and Squash Blocks) are not deslgne<f by this software. Products manufactured at Weyerhaeuser fadlltles are thlrcl-partv certified to sustainable forest,y standards. Wevert,aeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESll-1153 and ESR-1387 and/0< tested in accordance with applicable ASTM standards. For current code evalua~on reports, Weyerhaeuser product Uterature and Installation debllls refer to www.wevert,aeuser.comfwc,odproducts/docvment·ffbrary. The product appllcatton, Input design loads, dimensions and support lnfoonatton have been provided by ForteWES Software Operator ForteWH Software Opentor JobN- Paul Olristenson PCS0Englneer1ng (760) 207-1885 paul,pc:sdOgmall.com ~rhacum 2/12/2020 12:42:42 AM UTC ForteWEB v2.3, Engine: VS.0.0.21, Data: V7.3.2.0 File Name: Dominic Page 1 / 1 0 MEMBER REPORT Floor Framing, (FB-6) Hdr Bm 1 piece(s) 4 x 12 Douglas Fir-Larch No. 2 O.,erafl Length: 3' 1" All locatlons are measured from !tie outside face of left support ( or left cantilever end). All dimensions are horizontal. •: ~{;~-.r,u 'i~~·~-,, '::c•·,~,.':.' --.irrr:., -. ,, ,;U)fl., ~~~};,,1? Member Reaction (lbs) 4539@ 2' 11· 7656 (3.50") Passed (59%) -1.0 D + 1.0 L (All Spans) Shear (lbs) 3347 @ 1' 10 l/4" 4725 Passed (71 %) 1.00 1.0 0 + 1.0 L (All Spans) Moment (Ft-lbs) 4714@ 1' 8" 6091 Passed (n%) 1,00 1.0 D + 1.0 L (AH Spans) Live Load Den. (In) 0.005 @ 1' 6 5/8" 0.092 Passed (l/999+) .. 1.0 D + 1.0 L (All Spans) Total Load Deft. (in) 0.008@ 1' 6 5/8" 0.138 Passed (L/999+) -1.0 0 + 1.0 L (All Spans) • Oellectlon att2r11: LL (lJ360) and TL (LJ240). • Top Edge Bracing (Lu): Top compression edge must be braced at 3' 1• o/C based on loads applied, unless detailed oth~. • Bottom Edge Brlldng (Lu): Bottom compression edge must be braced at 3' 1• o/c based on loads applied, unless detailed otherwise. • Applicable calcula~ons are based on NDS. 2 • Column· OF 3.50' 3.50" 2.01• 1629 2910 338 • Bloddng Panels are assumed tx> carry no loads applied directly above them and the full load Is applied tx> the member being designed. ,.e., .1~ . .,I PASSED .. 0 System : Floor Member Type : Drop Beam Building Use : Residential EJuildlng Code : !BC 2018 Design Melhodology : ASO Weyerhaeuser warrants that the sizing of Its products w;a be In accordance with Weyerhaeuser product design criteria and publshed design values. Weyerhaeuser expressly disclaims any ott>er warranties related ID the software. Use of this software Is not Intended to drwmvent the need for a design professional as determined by the authority having jur1sdiCl!On. The desi!Jner of record, builder or framer Is responsible to assure that this calculation Is compatible with the over.au project. Accessortes (Rim Board, Blocking Panels and SQ<Jash Blocks) are not designed by this software. Products manufacllJred at Weyerhaeuser fadlties are thlrd-!)arty certified to sustainable fo,estry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by !CC-ES under evaluation reports ESR-1153 and ESR-1387 and/o, tested in accordance with applicable ASTM standards. for current code eval.Jation reports, Weyerhaeuser product literature and lnstaUat!oo details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support Information have been provided by forteWES S01\ware Operator l'orteWU Software 0-,.1:ot' Job Notes Paul Olrlstenson PCSO Engineering (760) 207-1885 A paut.pad@gmall.com Weytrhacuscr 2/12/2020 12:47:26 AM UTC ForteWEB v2.3, Engine: VS.0.0.21, Data: V7,3,2.0 File Name: Dominic Page 1 / 1 ? ,ru/r;'A°'ruien.ron 'efnt 2f"'Jo £;,JV'eeTUIJ JOB SHEET NO CALCULATED BY CHECK BY SCALE 19-525.1 UI OF_-.,..,...,...~ PSC DATE 2/28/20 DATE ---------3529 Coastview Ct -Carlsbad, CA 92010 Telephone (760) 207-1885 -Email: paul.pcsd@gmail.com S.O Lateral Design & Analysis (Four-Story) Wind: P = A Kzt I ps30 'A = 1.55 Kzt = 1.0 PS30 = 26.6 psf I = 1.0 P = 24.7 £Sf Wind Loads (ASCE 7 • Equation <>-I) (fig 6-JJ (fig 6-4) (6g. o-3) (table 11 5-1) Seismic: V = C5WoL S = s 1.1 F= a 1.1 R = 6.50 V = 0.085 • Wt Criteria ht Story Each Story Resists > 35% Base Shear: not satisfied (!BC Equation 12.8-1) S1 = 0.397 Fv = 0.0 I = 1.00 (p -Redundancy) 2nd Story 3rd Story not satis tied not satisfied P = 24.7 psfx trib. Area Any Shear Wall w/ (M)> 1.0 is < 33% Story Force: satisfied satisfied satisfied 4th Level p = 1.0 1 1.0 Direction: N /S = 24.7 psf X 305 sq. ft.= 7545 Jbs. Direction: EI W = 24.7 psf X 405 sq. ft.= 10019 lbs. 3rd Level Direction: N I S = 24.7 psf X 461 sq. ft.= 11404 lbs. Direction: E I W = 24.7 psf X 540 sq. ft.= 13359 lbs. 2nd Level Direction: N / S = 24.7 psf X 461 sq. ft.= 11404 lbs. Direction: E /W = 24.7 psf X 305 sq. ft.= 7545 lbs. 1st Level Direction: N I S = 24.7 psf X 442 sq. ft.= 10934 lbs. Direction: E I W = 24.7 psf X 305 sq. ft.= 7545 lbs. Seismic Loads 4th Level Weight 2nd Level Weight Diaphragm = 15.0 psf X 1168 sq. ft = 17520 lbs. Diaphragm = 15.0 psfx 1396 sq. ft = 20940 lbs Ext Wall Wt = 15.0 psf X 777 sq. ft = 11655 lbs. Ext Wall Wt = 15.0 psfx 1196 sq.ft= 17940 lbs Int Wall Wt=-8.0 psf X 660 sq. ft = 5280 lbs. Int Wall Wt= 8.0 psfx 1032 sq. ft= 8256 lbs Ceil'g Wt = 6.0 psf X 0 sq. ft= 0 lbs. Roof Wt= 15.0 psfx 0 sq. ft= 0 lbs Total Trib. WR = 34455 lbs. Total Trib. WR= 47136 lbs 3rd Level Wei~ht 1st Level Weight Diaphragm = 15.0 psfx 1481 sq.ft = 22215 lbs Diaphragm = 15.0 psfx 1435 sq. ft = 21525 lbs Ext Wall Wt = 15.0 psfx 1144 sq. ft= 17160 lbs Ext Wall Wt = 15.0 psfx 1185 sq.ft= 17775 lbs Int Wall Wt= 8.0 psfx 988 sq. ft = 7904 lbs lnt Wall Wt= 8.0 psfx 1023 sq. ft = 8184 lbs Roof Wt = 15.0 psf X 0 sq. ft = 0 lbs Roof Wt = 15.0 psfx 0 sq. ft = 0 lbs Total Trib. WR= 47279 lbs Total Trib. WR= 47484 lbs Total Seismic Dead Load: Wt= 176354 lbs. ASD Base Shear: V = 0.085 * Wt= 15064 lbs. ,?" ,u./f;,tnmn,.rc,,r ';Im, 2fuyo .£,JV'INJTUIJ 3529 Coastview Ct-Carlsbad, CA 92010 Telephone (760) 207-1885 -Email: paul.pcsd@gmall.com Seismic Lateral Distribution V = 15064 rbs. • p F Level Wx hx Wx hx k w. Ch. i (lbs) (ft) (lbs-ft) I w-(h;\ (lbs) 4th 34455 39 1343745 0.333 5013 3rd 47279 29 1371091 0.340 5115 2nd 47136 19 895584 0.222 3341 1st 47484 9 427356 0.106 1594 2; ·fI~1if\iii ;f~,:~~t~~~ 4037776 1.000 15064 ·~~-:-~1-:.? ··-.. --.;;t ~ r·f~;~. ·_ .· .. t -~ - r'-'-.· ~-~f+f;y }t _..:;_;):, ·.. •"' j.... ~ ~ ,,,.. ' ····· -,: r.t.';,H~·..:,J /;;~·~..:s,-·· ;..:i,~1 ., '·"'"";,J,~ ... ~,; ·'. _..,,.q,, JOB 19-525.1 SHEET NO \\ OF ___ _ CALCULATED BY PSC DATE 2/28/20 CHECK BY _____ DATE __ _ SCALE V (lbs) 5013 10129 13470 15064 PCSD Engineering Corp 3529 Coastview Court Carlsbad, CA 92010 Ph: 760-207-1885 11 l\a.\.u ; :, .6S°3Pi£--< 71v ~,~rn"tt Job#: l 1-nr Page: \ 1.. of ____ _ Date: ~-2-to Engineer: ________ _ JOB 19-525.1 ?truff;,f'r1m,n,,,n 'eJ'n, ,15~" .l:"nJV'eennJ SHEET NO l3 OF I) CALCULA TED'""'.'.'.B'.'"""Y~ ........ PS_C_ DATE 2/28/20 CHECK BY DATE 3529 Coastview Ct -Carlsbad, CA 92010 SCALE Telephone (760) 207-1885 -Email : paul.pcsd@gmail.com 6.0 FOUNDATION DESIGN 6.1 CONTINUOUS FOOTING w = 1125 plf width = 1125 plf 1500 psf 0.75 ft (MIN.) => 9 INCHES (MIN.) ( E) 15 11 WIDE CONTIN. FTG W/ l -# 4 TOP AND BOTTOM & EMBED. 18 11 INTO UNDISTURBED SOIL (MIN.) ASBP = 1500 psf 6.2 MAX POINT LOAD ON FOOTING 6.3 PAD DESIGN PAD PI I I 2(0+p) I I SIZE 32 ""SQUARE x 12 "'THK WI 4 -# 4 EACH WAY P.11 = 1500 • J2_ • ~ 12 12 P a11 = 7500 lbs LOAD Pmax = 1500 • 3 2 P max = I 0667 lbs --- + 0 12 41 [TI MEMBER REPORT Roof Framing, (RR-2) Rafters 1 piece(s) 2 x 6 Douglas Fir-Larch No. 2 @ 16" OC Sloped length: 11' 1 7/8" 10' All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. . Desliin,.~lt:s'f<"'.""'.'0!' ~ ~1:t,t#clat1~'\S ~-t~loji(~'1-,:;i !,lili!u.tr\1J•~t(~t r~t;o,.t ,I.Oael:'.Cciiiib-.c;ill,(~)t'.'.1" ,:. ::£,-l:\-,''t'i Member Reaction (lbs) 253@ 2 1/2" 3281 (3.50') Passed (8%) -1.0 D + 1.0 Lr (All Spans) Shear (lbs) 218 @ 8 11/16" 1238 Passed (18%) 1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs) 617@ 5' 3 1/2" 1060 Passed (58%) 1.25 1.0 0 + 1.0 Lr (All Spans) live Load Defl. (In) 0.214@ 5' 3 1/2" 0.536 Passed (l./601) -1.0 D + 1.0 Lr (All Spans) Total Load Deft, (In) 0.383 @ 5' 3 1/2" 0.714 Passed (l./336) -1.0 D + 1.0 Lr (All Spans) • Deflection crttffil: LL (IJ2◄0) and TL (L/180), • Top Edge Bracill!I (Lu): Top ccmpresslon edge must be braced at 11' 2" o/c based on loads applied, unless detailed othenYise. • Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 11' 2• o/c based on loads applied, unless detailed otherwise. • A 15% lnaease In the moment capacity has been added to account for repetitive member usage. • Applicable calculations are based on NOS. PASSED Member L!ngth: 11' 3 11/16" System : Roof Member~ : Joist Bulldlng Use : Resldentlal fJuildlng Code: JBC 2018 Design Methodology : ASD Member Pitch : 4/12 Weyerhaeuser warrants that the slzlng of Its products will be In accordance with Weyerhaeuser product design criteJ1a and pubDshed design values. Weyerhaetl.er expressly disclaims any 0th..-warranties related to the software. Use of 1111s software Is not Intended to circumvent the need for a design professional as determined by the authority having Jurisdiction. The designer of record, builder or framer Is responstble to assure that this calculation ls compatible with the overall project. Accessories (Rim Board, Blocldng Panels and Squash Blocks) are not designed by thls software, Products manufactured et Weyerhaeus..-facilities are third-party certified to sustslnable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES underevaluatlon reports ESR-1153 and ESR-1387 and/or tested In aca,rdance with applicable ASTM standams. For current code evalUatlon reports, W-haeuser product fiterature and Installation detells refer to www.weyerhaeuser.com/woodproducts/document-llbrary. The product appllcaUon, Input design loads, dimensions and support Information have been provided by ForteWEB Soltware Operator forteWEB Saftw•re Oper■tor JobNotu Paul O,rtst,,mon PCSD Engineering (760) 207-1885 A paul,pc:sd@gmall.com 5/21/2020 6:36:31 PM UTC ForteWEB v2.4, Engine: VS.0.1.S, Data: V7.3.2.0 Flle Name: Grant Page 1 / 1 -----------i~~o~~ ..... ....-IU (city of Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 IJ~_velopment Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of permits are not required to fill out this form ❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool _. If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. _. Details on CAP ordinance requirements are available on the city's website. _. A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and download the latest form. Project Name/Building Permit No.: VILLA MIRA A LA COSTA, HOA BP No. ~2C 20-00l ll) Property Address/APN 2459 Ocean Street / 2030210201, 2030210202, 2030210203 Applicant Name/Co. JON PRICE/ SPACES RENEWED Applicant Address 1107 S COAST HWY, OCEANSIDE, CA 92054 Contact Phone: 760-390-0067 Contact Email: jon@spacesrenewed.com Contact information of person completing this checklist (if different than above): Name: Company name/address: SAME AS ABOVE Contact Phone: Contact Email: Applicant Signature: --(Jifa+--+1---,~-'-_______ Date 5/1/2020 B-50 Page 1 of 6 Revised 06/18 City of Carlsbad Climate Action Plan Consistency Checklist Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For alterations and additions to existing buildings, attach Building Permit Valuation worksheet. Building Permit Valuation (BPV) from worksheet: $. _____ _ Construction Type I Complete Section(s) I Notes: A high-rise residential building is 4 or more stories, including a , [Z] Residential Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor area is residential use □ New construction 0 Additions and alterations: □ BPV < $60,000 N/A N/A All residential additions and alterations □ BPV 2: $60,000 1A, 4A 4A 1-2 family dwellings and townhouses with attached garages □ Electrical service panel upgrade only only 'Multi-family dwellings only where interior finishes are removed □ BPV 2: $200,000 1A, 4A' 1 B, 4A' and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed D Nonresidential □ New construction 1 B, 2B, 3B, 4B and 5 □ Alterations: □ BPV 2: $200,000 or additions 2: 1,000 1B, 5 square feet □ BPV 2: $1,000,000 1B, 2B, 5 Building alterations of 2: 75% existing gross floor area □ 2: 2,000 sq. ft. new roof addition 2B,5 1 B also applies if BPV 2: $200,000 Check the ~tio•. explal\ all not applicable and exception items, and p!Mle supp(!ltingcalcUlalions arntdQtllmenta1iOl!iis118CeSS8ry. 1. Energy Efficiency Please refer to Carisbad Municipal Code (CMG) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CALGreen) for more infom,ation when completing this section. A D Residential addition or alteration~ $60,000 building permit valuation, See CMC section 18.30.190, Year Built Single-family Requirements □ Before 1978 Select one: □ Duct sealina □ Attic insulation □Cool roof □ 1978 and later Select one: □ Lighting package □ Water heating Package □ Between 1978 and 1991 □ 1992 and later □ N/A. _________ _ □ Exception: Home energy score~ 7 (attach certification) Multi-family Requirements □ Attic insulation Select one: □ Duct sealina □ Attic insulation □Cool roof Select one: □ Lighting package □ Water heating package B. D Nonresidential' new construction or alterations~ $200,000 building permit valuation, or additions ~ 1,000 square feet □ NIA Updated 8/15/20 I 9 2 '• City of Carlsbad Climate Action Plan Consistency Checklist See CMC 18,21,155 and CALGreen Appendix AS, Division AS.2-Energy Efficiency. A5.203.1.1 Choose one: □ .1 Outdoor lighting □ .2 Warehouse dock seal doors □ .3 Restaurant service water heating (oomply ~th California Energy Code section 140.5, as amended) □ NIA _________ _ □ .4 Daylight design PAFs □ .5 Exhaust air heat recovery A5.203.1.2.1 Choose one as applicable: □ .95 Energy budget □ .90 Energy budget □ NIA A5.211.1tt □ On-site renewable energy □ NIA A5.211.3tt □ Green power (if offered by local utility provider, 50% minimum renewable sources) □ NIA A5.212.1 □ Elevators and escalators □ NIA A5.213.1 □ Steel framing □ NIA 'lnciudes hotels/motels and high-rise residential buildings tt For alterations" $1,000,000 8PV and affecting > 75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: oomply with CMC 18.30.130 instead. 2. Photovoltaic Systems A. D Residential new construction (for low-rise residential building pennit applications submitted after 1/1/20). Refer to 2019 California Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic requirement (28 below) instead. 2) If project includes installation of an electric heat pump water heater pursuant to CMC 18.30.150(8) (high-rise residential) or 18.30.170(6) (low-rise residential), increase system size by .3kWdc if PV offset option is selected. Floor Plan ID (use additional CFA #d.u. Calculated kW1c' sheets if necessary) Total System Size: kW1c = (CFAx.572) / 1,000 + (1.15 x#d.u.) 'Fomnula calculation where CFA = oonditional floor area, #du= number of dwellings per plan type If proposed system size is less than calculated size, please explain. Exception □ □ □ □ kW1c 8. D Nonresidential new construction or alterations 2$1,000,000 BPV and affecting 275% existing floor area, or addition that increases roof area by 22,000 square feel Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to high-rise residential and hotel/motel buildings. Choose one of the following methods: □ Gross Floor Area (GFA) Method GFA: □ If< 1 O,OOOs.f Enter: 5 kWdc Min. System Size: □If" 10,000s.f. calculate: 15 kWdc x (GFN10,000) •• __ kWdc "Round building size factor to nearest tenth, and round system size to nearest whole number. □ Time-Dependent Valuation Method Updated 8/15/2019 3 City of Carlsbad Climate Action Plan Consistency Checklist Annual TDV Energy use:••• ______ x .80= Min. system size: _____ kWdc ... Attach calculation documentation using modeling software approved by the California Energy Commission. 3. Water Heating A D Residential and hotel/motel new construction Please refer to CMC sections 18.30.150 and 18.30.170 when completing this section. D For systems serving individual dwelling units choose one: D Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) D Heat pump water heater AND PV system .3 kWdc larger than required in CMG section 18.30.130 (high rise residential hotel/motel) or CA Energy Code section 150.1 (c) 14 (low-rise residential) D Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher D Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors D Exception: D For systems serving multiple dwelling units, install a central water-heating system with all of the following: D Gas or propane water heating system D Recirculation system per CMG 18.30.150(B) (high-rise residential, hotel/motel) or CMG 18.30.170(B) (low- rise residential) D Solar water heating system that is either: D .20 solar savings fraction D .15 solar savings fraction, plus drain water heat recovery □Exception: B. D Nonresidential new construction Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section. D Water heating system derives at least 40% of its energy from one of the following (attach documentation): D Solar-thermal D Photovoltaics D Recovered energy □Water heating system is (choose one): 0 Heat pump water heater 0 Electric resistance water heater(s) □Solar water heating system with .40 solar savings fraction D Exception: Updated 8/15/2019 4 City of Carlsbad Climate Action Plan Consistency Checklist 4. Electric Vehicle Charging A D Residential New construction and major alterations' Please refer to Carlsbad Ordinance CMC section 18.21.140 when com letin this section. One and two-family residential dwelling or townhouse with attached garage: Done EVSE Ready parking space required D Exception: D Multi family residential -D Exception · Total Parking Spaces EVSE Spaces Proposed Capable Readv Calculations: Total EVSE spaces= .10 x Total parlling (rounded up to nearest whole number) EVSE Installed = Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other= Total EVSE spaces -EVSE Installed (EVSE other may be "Capable," "Ready" or "Installed.") Installed Total 'Major alterations are: (1) for one and two-family dwellings and townhouses v.nth attached garages, alterations have a building pennit valuation~ $60,000 or include an electncal service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), alterations have a building pennit valuation~ $200,000, intenor finishes are removed and significant site worll and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed. B D Nonresidential new construction (includes hotels/motels) D Exception · Total Parking Spaces EVSE Spaces Proposed Caoable Readv Installed I Total 10 2 5 1 I 8 Calculation· Refer to the table below· Total Number of Parllina Soaces orovided Number of =uired EV Soaces Number of r»nuired EVSE Installed Spaces □ 0-9 1 1 I 10-25 2 1 □ 26-50 4 2 □ 51-75 6 3 □ 76-100 9 5 I 101-150 12 6 I 151-200 17 9 I 201 and over 1 O nPrcent of total 50 oercent of Required EV Spaces Updated 8/15/2019 5 City of Carlsbad Climate Action Plan Consistency Checklist 5. D Transportation Demand Management (TDM): Nonresidential ONLY AA approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT. City staff will use the table below based on your submitted plans to detenmine whether or nor your penmit requires a TOM plan. If TOM is applicable to your penmit, staff will contact the applicant to develop a site-specific TOM plan based on the penmit details. Acknowledgment: Employee ADT Estimation for Various Commercial Uses Use EmpADTfor first 1,000 s.f. EmpADT/ 1000 s.f.1 Office (all)2 20 Restaurant 11 Retail3 8 Industrial 4 Manufacturing 4 Warehousin 4 1 Unless otherwise noted, rates estimated from /TE Trip Generation Manual, 10'hEdition 13 11 4.5 3.5 3 1 2 For all office uses, use SAN DAG rate of 20 ADT/1,000 sf to calculate employee ADT 3 Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration Sample calculations: Office: 20,450 sf 1. 20,450 sf/ 1000 x 20 = 409 Employee ADT Retail: 9,334 sf 1. First 1,000 sf= 8 ADT 2. 9,334 sf -1,000 sf= 8,334 sf 3. 8,334 sf I 1,000 x 4.5 + 8 = 46 Em lo ee ADT I acknowledge that the plans submitted may be subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should my penmit require a TOM plan and u rstand that an approved TOM plan is a condition of penmit issuance. Date 5/1/2020 Person other than Applicant Name(Printed): __________________ _ Phone Number: ____ _ Email Address: __________________ _ Updated 8/15/20 I 9 6