HomeMy WebLinkAbout2459 OCEAN ST; C; CBRA2020-0160; PermitPERMIT REPORT
(city of
Carlsbad
Residential Associated Permit
Print Date: 03/31/2022
Job Address:
Permit Type:
Parcel#:
Valuation:
Occupancy Group:
#of Dwelling Units:
Bedrooms:
Bathrooms:
2459 OCEAN ST, # C, CARLSBAD, CA 92008-2273
BLDG-Associated Permit Residential Work Class: Addition
2030210201 Track#:
$19,717.25 Lot#:
Project#: DEV2020-0050
Plan#:
Construction Type:
Orig. Plan Check#: PC020-0016
Plan Check#:
Project Title: VILLA MIRA ALA COSTA
Permit No: CBRA2020-0160
Status: Closed -Finaled
Applied: 07/09/2020
Issued: 07/10/2020
Fina led Close Out: 03/31/2022
Inspector:
Final Inspection:
CRenf
02/11/2022
Description: VILLA MIRA ALA COSTA: 250 SF REMODEL// 20 SF ADDITION// NEW WINDOWS AND DOORS// RE-ROOF
Applicant: Property Owner:
SPACES RENEWED
JON PRICE
1107 S COAST HWY
OCEANSIDE, CA 92054
(760) 390-0067
GRANT TIMOTHY L NANNETTE L
8907 E RAINTREE DR, # 140
SCOTTSDALE, AZ 85260
FEE
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
BUILDING PLAN CHECK FEE (BLDG)
SB1473 GREEN BUILDING STATE STANDARDS FEE
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
STRONG MOTION-RESIDENTIAL
BUILDING PERMIT FEE ($2000+)
Total Fees: $653.78 Total Payments To Date: $653.78
Contractor:
REMODEL SOLUTIONS
1107 S COAST HWY
OCEANSIDE, CA 92054-5101
(760) 637-2175
Balance Due:
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
AMOUNT
$175.00
$142.56
$1.00
$39.00
$41.00
$49.00
$2.56
$203.66
$0.00
PERMIT INSPECTION HISTORY for (CBRA2020-0160)
Permit Type: BLDG-Associated Permit Residentii
Work Class: Addition
Status: Closed -Finaled
Scheduled Actual Inspection Type
Date Start Date
Thursday, March 31, 2022
Application Date: 07/0912020 Owner: COOWNER DOMINICK TODD A AND
MICHELLE J, COOWNER GRANT
TIMOTHY L NANNETTE L, COOWNER
SAYER KEVIN RAND MARGOT B
Issue Date: 07/10/2020 Subdivision: PARCEL MAP NO 09986
Expiration Date: 10/18/2021
IVR Number: 27362
Address: 2459 OCEAN ST, # C
CARLSBAD, CA 92008-2273
Inspection No. Inspection Primary Inspector Reinspection Inspection
Status
Page4of4
PERMIT INSPECTION HISTORY for (CBRA2020-0160)
Permit Type: BLDG-Associated Permit Resident,,
Work Class: Addition
Status:
Scheduled
Date
Closed -Finaled
Actual Inspection Type
Start Date
Application Date: 07/09/2020 Owner: COOWNER DOMINICK TODD A AND
MICHELLE J, COOWNER GRANT
TIMOTHY L NANNETTE L, COOWNER
SAYER KEVIN RAND MARGOT B
Issue Date: 07/10/2020 Subdivision: PARCEL MAP NO 09986
Expiration Date: 10/18/2021
IVR Number: 27362
Inspection No. Inspection
Status
Address: 2459 OCEAN ST, # C
CARLSBAD, CA 92008-2273
Primary Inspector Reinspection Inspection
BLDG-34 Rough Electrical Februaiy 26, 2021: Yes
04/19/2021 04/19/2021
02/11/2022 02/11/2022
Thursday, March 31, 2022
BLDG-44
Rough-Ducts-Dampers
BLDG-17 Interior
Lath/Drywall
Checklist Item
1. Rough combination inspection for
plumbing, electrical, framing, and
mechanical scope of work -approved.
2. Anchor bolts missing at bottom
plate-breaks.
a) install New anchor bolt no more than 12
inches from bottom sole plate-break.
3. Ground screws missing at metal light
fixture pancake and receptacle boxes
(typical).
4. (1) downstairs bedroom smoke detector
required and needs to be installed.
5. Plumbing and gas lines under water/air
leak test and insulated, scope of
work-approved.
6. stucco lath paper, weep screed, scope
of work-partial pass.
February 26, 2021:
1. Rough combination inspection for
plumbing, electrical, framing, and
mechanical scope of work -approved.
2. Anchor bolls missing at bottom
plale-breaks.
a) install New anchor bolt no more than 12
inches from bottom sole plate-break.
3. Ground screws missing at metal light
fixture pancake and receptacle boxes
(typical).
4. (1) downstairs bedroom smoke detector
required and needs to be installed.
5. Plumbing and gas lines under water/air
leak test and insulated, scope of
work-approved.
6. stucco lath paper, weep screed, scope
of work-partial pass.
155295-2021 Passed Paul Burnette
COMMENTS
BLDG-Building Deficiency
BLDG-Final Inspection 176432-2022 Passed Tony Alvarado
Checklist Item COMMENTS
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Yes
Yes
Yes
Page 3 of 4
", • !.-,._" ,
t PERMIT INSPECTI~.N HISTORY,; for (CBRA2020-0160)
Permit Type: BLDG-Associated Permit Residenti; Application Date: 07/09/2020 Owner: COOWNER DOMINICK TODD A AND
MICHELLE J, COOWNER GRANT
TIMOTHY L NANNETTE L, COOWNER
SAYER KEVIN RAND MARGOT B
Work Class: Addition
Status: Closed -Finaled
Issue Date: 07/10/2020
Expiration Date: 10/18/2021
IVR Number: 27362
Subdivision: PARCEL MAP NO 09986
Address: 2459 OCEAN ST, # C
CARLSBAD, CA 92008-2273
Scheduled
Date
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector Reinspection Inspection
Thursday, March 31, 2022
Checklist Item
BLOG-Building Deficiency
BLOG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Roug h-T opout
COMMENTS
Not ready
February 26, 2021:
1. Rough combination inspection for
plumbing, electrical, framing, and
mechanical scope of work-approved.
2. Anchor bolts missing at bottom
plate-breaks.
a) install New anchor bolt no more than 12
inches from bottom sole plate-break.
3. Ground screws missing at metal light
fixture pancake and receptacle boxes
(typical).
4. (1) downstairs bedroom smoke detector
required and needs to be installed.
5. Plumbing and gas lines under water/air
leak test and insulated, scope of
work-approved.
6. stucco lath paper, weep screed, scope
of work-partial pass.
February 26, 2021:
1. Rough combination inspection for
plumbing. electrical, framing, and
mechanical scope of work-approved.
2. Anchor bolts missing at bottom
plate-breaks.
a) install New anchor bolt no more than 12
inches from bottom sole plate-break.
3. Ground screws missing at metal light
fixture pancake and receptacle boxes
(typical).
4. (1) downstairs bedroom smoke detector
required and needs to be installed.
5. Plumbing and gas lines under water/air
leak test and insulated, scope of
work-approved.
6. stucco lath paper, weep screed. scope
of work-partial pass.
Passed
No
Yes
Yes
Page 2 of 4
Building Permit Inspection History Finaled
{City of
Carlsbad
PERMIT INSPECTION HISTORY for (CBRA2020-0160)
Permit Type: BLDG-Associated Permit Residenfo Application Date: 07/09/2020 Owner: COOWNER DOMINICK TODD A AND
Work Class:
Status:
Scheduled
Date
07/2112020
08/27/2020
01/26/2021
02/01/2021
02/26/2021
Addition Issue Date: 07/10/2020
MICHELLE J, COOWNER GRANT
TIMOTHY L NANNETTE L, COOWNER
SAYER KEVIN RAND MARGOT B
Closed -Finaled Expiration Date: 10/18/2021
Subdivision: PARCEL MAP NO 09986
Address: 2459 OCEAN ST, # C
CARLSBAD, CA 92008-2273
Actual
Start Date
07/21/2020
IVR Number: 27362
Inspection Type Inspection No. Inspection Primary Inspector
Status
BLDG-11 133426-2020 Partial Pass Chris Renfro
Foundation/Ftg/Piers
(Rebar)
Checklist Item COMMENTS
BLDG-Building Deficiency Partial pass on (3) pier footings, and first
floor footing. Need special inspection
report of epoxy HDU8 x 2
08/27/2020 BLDG-11 136736-2020 Passed Tony Alvarado
01/26/2021
02/01/2021
02/26/2021
Foundation/Ftg/Piers
(Rebar)
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
August 27, 2020:
1. Partial pass on (3) isolated pad footings,
per structural engineers plans/details -
approved.
Partial pass on (3) pier footings, and first
floor footing. Need special inspection
report of epoxy HDU8 x 2
BLDG-13 Shear 149124-2021 Partial Pass Chris Renfro
Panels/HD (ok to wrap)
Checklist Item COMMENTS
BLDG-Building Deficiency Partial pass on interior shear walls. Special
inspection report collected
BLDG-84 Rough 149513-2021 Failed Chris Renfro
Com bo(14,24, 34,44)
Checklist Item COMMENTS
BLDG-Building Deficiency Not ready
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
BLDG-84 Rough 151547-2021 Partial Pass Tony Alvarado
Combo(14,24,34,44)
Reinspection Inspection
Reinspection Incomplete
Passed
Yes
Complete
Passed
Yes
Yes
Re inspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
No
No
No
No
No
Relnspectlon Incomplete
Thursday, March 31, 2022 Page 1 of 4
SPECIAL INSPECTION RECORD
I HAVE PROJIIED <N SITE O ~
SPECIAL INSPECTI<N SERVICES O MASCNRY
FOR THE FOLI.£:w.IN:; ITEMS : 0 FIREPROOFJN:;
PROJECT: Dominic Resd
ADOOESs : 2459 Ocean St.
crTY/AHJ: arlsbad
TIME lN: cur: MII.E.5:
MII.TERIAL:
Onsite fore
0 STEEL ASSEMBLY /WELDm; !XI EKlXY AN<liORS/D:lvELS
CiJ SHFAR WALL rnAMn,K; SYSTEl1
BLCG PERMIT:
avNER:
AROilTECI':
CXNIW\CI'CR:
Sl.JECXNl'RACI':
ecial ins ection
FEPRESENTATIVE)
I HEARBY AI<NavIEIXE THAT SfECIAL INSIBCTI<N OCE5 00!' RELIEVE ME THE avNER, <XNI'RACfCR, OOIIDER CR FEPRESENI'ITIVE OF MY
RESECNSIBILITY TO ASSURE THAT ALL WORK IS PERFrnMED !:ER THE APPRO\lED PI.ANS, SPECIFICATICNS AND APPLICABLE BJILDm; CXl!E.
FOR PNY ITEMS PLFASE SOiECULE FOR FE-INSPECTICN. ALL WORK PERFCllMED IS BILLED IN 4 HaJR INrnEMENI'S SEE OOR CWRENI' FATES.
I HFARBY PGREE TO IlilrnNIFY AND HOLD HARMIESS THE INSFECTCR ALCN:; WITH PNY AND ALL ASSOCIATED ENI'ITIE'.5 FOR PNY AND ALL
CIAIMS OF/FCR CJAM1IU:.5 WHETHER .na::IDFNI'AL CR mIENTICNAL. I HEARBY FELFASE THE INSPECKR AI..CNG WITH PNY AND ALL ASSCCIA'IED
ENI'ITIE'.5 EROIM PNY AND ALL CIAIMS KNCWN CR UNKN::WN THAT MAY HAVE ARISEN, CR MAY ARISE ERCM THE INSPECTI<N OF THE I>KNF,
ITEMS. I HEARBY AGREE TO PK:i FOR PNY AND ALL ATI'ORNEY AND OXJRT COSTS RE@RDI.FSS OF FlNDIN:iS . I WILL PK:i FOR l>N'f AND ALL
JUr:GlENI'S BRaGIT AGAINSI' THE INSPECTCR AND/CR JlRY REIATED ENI'ITIES OOE TO ANY'I'HJN'.; REIATED TO THIS PROJECT WHATSCEVER.
avNER: CXNI'RACI'CR: Eric