Loading...
HomeMy WebLinkAbout2606 COLIBRI LN; 2; CBR2021-0194; PermitPERMIT REPORT Residential Permit Print Date: 03/07/2022 Job Address: 2606 COLIBRI LN, # #2, CARLSBAD, CA 92009-4303 Permit Type: BLDG-Residential Work Class: Parcel#: 2155340700 Track#: Valuation: $67,416.48 Lot#: Occupancy Group: #of Dwelling Units: 1 Bedrooms: Bathrooms: Project Title: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Second Dwelling Unit Description: TEMBI: (244SF) ADDITION AND (532SF) REMODEL TO CREATE ADU (776SF) Applicant: Property Owner: JEFF PARSHALLE ARCHITECT JEFF PARSHALLE TEMBI ALICIA ROSENBERG AND ZACKIYE 2606 COLIBRI LN PO BOX 230132 CARLSBAD, CA 92009 ENCINITAS, 92023 (619) 985-4099 FEE MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL BUILDING PERMIT FEE ($2000+) STRONG MOTION-RESIDENTIAL 5B1473 GREEN BUILDING STATE STANDARDS FEE BUILDING PLAN CHECK FEE (BLDG) GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION SWPPP INSPECTION FEE TIER 1-Medium BLDG SWPPP PLAN REVIEW FEE TIER 1-MEDIUM ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL Total Fees: $1,466.81 Total Payments To Date: $1,466.81 (city of Carlsbad Permit No: CBR2021-0194 Status: Closed -Finaled Applied: 01/22/2021 Issued: 04/06/2021 Finaled Close Out: 03/07/2022 Inspector: Final Inspection: Balance Due: PBurn 12/21/2021 AMOUNT $52.00 $80.00 $485.74 $8.76 $3.00 $318.31 $175.00 $246.00 $55.00 $43.00 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov # (___ City of Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 PC Deposit -----,,----,r---- D ate 1/;p/x,;;y I ..,_ Job Address 2606 Calibri Lane .,;f'z_. Suite: APN: 2/5-5 5--B t/ 01 ----~ CT/Project #:. __________________ Lot#:._7--5 ___ Year Built: _________ _ Fire Sprinklers: ()vES(!) NO Air Conditioning:(!) YES Q NO BRIEF DESCRIPTION OF WORK: Electrical Panel Upgrade: QYES(!) NO Within an existing single family home remodel existing habitable area and a covered exterior area to be an attached ADU. 0 Addition/New: 244 Living SF,, ____ Deck SF,, ____ Patio SF, ____ Garage SF __ _ Is this to create an Accessory Dwelling Unit? 0Y ON New Fireplace? OY 0N, if yes how many? __ D Remodel:._5_3_2 ____ SF of affected area Is the area a conversion or change of use? OY 0 N 0 Pool/Spa:. ____ SF Additional Gas or Electrical Features? ____________ _ □solar: KW, Modules,Mounted:0Roof0Ground, Tilt:OYON, RMA:OYON, Batterv:OY ON, Panel Upgrade: Ov ON D Reroof: __________________________________ _ D Plumbing/Mechanical/Electrical D Only: Other: This permit is to be issued in the name of the Property owner as Owner-Builder. licensed contractor or Authorized Agent of the owner or contractor. The person listed as the Applicant below wiJ/ be the main point of contact throughout the permit process. PROPERTY OWNER Name: Zack Tembi Address: 2606 Calibri Lane APPLICANT ■ PROPERTY OWNERS AUTHORIZED AGENT APPLICANT 0 Name:. ____________________ _ Address: P.O. Box 230132 City: Carlsbad State: CA Zip: 92009 City:._E_n_c_in_ita_s ______ ---'State:_C_A __ Zip: 92023 Phone: 860-707-5437 Phone: ..;6 __ 1.:.9·--9--85:..-40_;,_9_9 ______________ _ Email: Z;:h" CQb i @ ~\ 9 Ct):fi)mail: .,_je.;;..ff-"@.....,jp'--'a;;;.r_ch_._n_e_t ___________ _ DESIGN PROFESSIONAL APPLICANT O CONTRACTOR OF RECORD APPLICANT 0 Name: Jeff Parshalle Architect Name: _________________ _ Address: P.O. Box 230132 Address:. __________________ _ City: Encinitas State:._C_A __ Zip: 92023 City:. ________ State: ___ Zip:. ______ _ Phone: 619-985-4099 Phone:. ___________________ _ Email: jeff@jparch.net Email:. _________________ _ Architect State License: Cl l 757 State License/class:. ______ Bus. License:. ____ _ 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602~2719 Fax: 760-602-8558 Email: Building@carlsbadca.:.RQ..Y_ REV. 08/20 i3/f:."!,/ /J19D IDENTIFY WHO WILL PERFORM THE WORK BY COMPLETING (OPTION AJ OR (OPTION BJ BELOW: (OPTION AJ: LICENSED CONTRACTOR DECLARATION: I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000} of Division 3 of the Business and Professions Code, and my license is in full force and effect. I also affirm under penalty of perjury one of the following declarations: 01 have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is Issued. Policy No. ________________________________________ _ 0 ! have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: _____________________ _ Policy No. ___________________________ ExpirationDate: ______________ _ 0 Certificate of Exemption: I certify that in the performance of the work for which this pennn is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec:. 3097 (i) Civil Code). Lender's Name: ______________________ Lender's Address: _____________________ _ CONTRACTOR PRINT: _________ SIGN: _________ DATE: (OPTION BJ: OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Low for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale {Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). ■ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's license law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's license Law). DI am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason: O"owner Builder ackno~edgement and verification form" has been filled out, signed and attached to this application. D Owners "Authorized Agent Form" has been filled out, signed and attached to this application giving the agent authority to obtain the permit on the owner's behalf By my signature below I acknowledge that, except for my persona! residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed contractors. I understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application is submitted or at thefoJJowing Web site: http://www.leginfo.ca.gov/calaw.html. OWNER PRINT: Zack Tembi ./ SIGN: .¥ DATE: 1/MQ!fl ---'----------------------- APPLICANT CERTIFICATION: SIGNATURE REQUIRED AT THE TIME OF SUBMITTAL By my signature below~ I certify that: I om the property owner or State of California Licensed Contractor or authorized to act on the property owner or contractor's behalf. I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with oil City ordinances and State Jaws relating to building construction. f hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CfTY OF CARLSBAD AGAINST ALL LIABILITTES, JUDGMENTS, com AND EXPENSES WHICH MA y IN ANY WAY ACCRUE AGAINST SAID Cl7Y IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA pe is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in heiqht. ~ APPLICANT PRINT: z k: l . ac err101 1635 Faraday Ave Carlsbad, CA 92008 / SIGN: Ph: 760-602-2719 Fax: 760-602-8558 2 Email: Bu_ildi..!J.R@.Carl_sbadca g_ov REV. 08120 {city of Carlsbad OWNER-BUILDER ACKNOWLEDGEMENT FORM B-61 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www .carlsbadca.gov OWNER-BUILDER ACKNOWLEDGMENT FORM Pursuant to State of California Health and Safety Code Section 19825-19829 To: Property Owner An application for construction permit(s) has been submitted in your name listing you as the owner---builder of the property located at: Site Address 2606 Colibri Ln. Carlsbad CA 92009 The City of Carlsbad ("City") is providing you with this Owner-Builder Acknowledgment and Verification form to inform you of the responsibilities and the possible risks associated with typical construction activities issued in your name as the Owner-Builder. The City will not issue a construction permit until you have read and initialed your understanding of each provision in the Property Owner Acknowledgment section below and sign the form. An agent of the owner cannot execute this notice unless you, the property owner, complete the Owner's Authorized Agent form and it is accepted by the City of Carlsbad. INSTRUCTIONS: Please read and initial each statement below to acknowledge your understanding and verification of this information by signature at the bottom of the form. These are very important construction related acknowledgments designed to inform the property owner of his/her obligations related to the requested permit activities. I. ZT I understand a frequent practice of unlicensed contractors is to have the property owner obtain an "Owner Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed contractor and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner-Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. II. ZT I understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed contractor to assume this responsibility. 111. ZT I understand as an "Owner .. Builder" I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit flied in his or her name instead of my own. IV. ZTI;j1 understand contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. V. ZT I understand if I employ or otherwise engage any persons, other than California licensed contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. REV. 08/20 Owner-Builder Acknowledgement Continued VI. ~I understand if I am considered an "employer" under state and federal law, 1 must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. VII. ZT I understand under California Contractors' State License law, an Owner--Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building contractor. VIII. ZT I understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) which result from any latent construction defects in the workmanship or materials. IX. ZT I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at l·.S00·-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. X. ZT I am aware of and consent to an Owner-·Bullder building permit applied for in my name, and understand that I am the party legally and financially responsible for proposed construction activity at the following address: 2606 Calibri Ln. Carlsbad CA 92009 XI. Z?JT I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner-Builders as well as employers. XII. ZTq I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractor's·State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner- Builder and wish to hire contractors, you will be responsible for verifying whether or not those contractors are properly licensed and the status of their workers' compensation coverage. Before a building permit can be issued, this form must be completed, signed by the property owner and returned to the City of Carlsbad Building Division. I declare under penalty of perjury that I have read and understand all of the information provided on this form and that my responses, including my authority to sign this form, is true and correct. I am aware that I have the option to consult with legal counsel prior to signing this form, and I have either (1) consulted with legal counsel prior to signing this form or (2) have waived this right in signing this form without the advice of legal counsel. Zack Tembi 4/5/21 Property Owner Name (PRINT) Property Owner Signature Date 2 REV. 08/20 ( City of Carlsbad OWNERS AUTHORIZED AGENT FORM B-62 Deve/onmen Services Buil ~ing Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov OWNER'S AUTHORIZED AGENT FORM Only a property owner, contractor or their authorized agent may submit plans and applications for building permits. To authorize a third-party agent to sign for a building permit, the owner's third party agent must bring this signed form, which identifies the agent and the owner who s/he is representing, and for what jobs s/he may obtain permits. The form must be completed in its entirety to be accepted by the City for each separate permit application. Note: The following Owner's Authorized Agent form is required to be completed by the property owner only when designating an agent to apply for a construction permit on his/her behalf. AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Property Owner Acknowledgement, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner-Builder Permit for my project. . . . . ADU remodel & addition Scope of Construction Proiect (or Description of Work): ___________________ _ . . 2606 Colibri Lane ProJect Location or Address: _____________________________ _ . Jeff Parshalle 619-985-4099 Name of Authorized Agent: __________________ Tel No. ________ _ Address of Authorized Agent: P. 0. Box 2301 32 Encinitas, CA 92023 I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its ac~------~-1 /14/21 Property Owner's Signature:-------'-------------Date: ______ _ PERMIT INSPECTION HISTORY for (CBR2021-0194) Permit Type: BLDG-Residential Work Class: Second Dwelling Unit Status: Closed -Finaled Application Date: 01/22/2021 Issue Date: 04/06/2021 Expiration Date: 03/02/2022 IVR Number: 31138 Owner: COOWNER TEMBI ALICIA ROSENBER( ANDZACKIYE Subdivision: CARLSBAD TCT#73-29 Address: 2606 COLIBRI LN, # #2 CARLSBAD, CA 92009-4303 Scheduled Date Actual Inspection Type Start Date Inspection No. Inspection Primary Inspector Reinspection Inspection 07/20/2021 07/26/2021 09/03/2021 12/21/2021 07/20/2021 BLDG-17 Interior Lath/Drywall 162365-2021 Checklist Item COMMENTS BLOG-Building Deficiency 07/26/2021 BLDG-27 Shower Pan/Tubs 162780-2021 Checklist Item COMMENTS BLOG-Building Deficiency 09/03/2021 BLDG-18 Exterior Lath/Drywall 165862-2021 Checklist Item COMMENTS BLDG-Building Deficiency 12/21/2021 BLDG-Final Inspection Checklist Item 173120-2021 COMMENTS BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Monday, March 7, 2022 Status Passed Paul Burnette Complete Passed Yes Passed Tim Kersch Complete Passed Yes Passed Tim Kersch Complete Passed Yes Passed Tim Kersch Complete Passed Yes Yes Yes Yes Yes Page 2 of 2 Building Permit Inspection History Finaled (cityof Carlsbad PERMIT INSPECTION HISTORY for (CBR2021-0194) Permit Type: BLDG-Residential Application Date: 01/22/2021 Owner: COOWNER TEMBI ALICIA ROSENBERC ANDZACKIYE Work Class: Second Dwelling Unit Issue Date: 04/06/2021 Subdivision: CARLSBAD TCT#73-29 Status: Closed -Finaled Expiration Date: 03/02/2022 Address: 2606 COLIBRI LN, # #2 IVR Number: 31138 CARLSBAD, CA 92009-4303 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 04128/2021 04128/2021 BLDG-SW-Pre-Con 156132-2021 Passed Paul Burnette Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 05119/2021 05/19/2021 BLDG-21 157692-2021 Passed Paul Burnette Complete Underground/Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 05/21/2021 05/21/2021 BLDG-11 157914-2021 Passed Tim Kersch Complete Fou n datio n/Ftg/P iers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 06/16/2021 06/16/2021 BLDG-13 Shear 159936-2021 Passed Paul Burnette Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 07/07/2021 07/07/2021 BLDG-84 Rough 161352-2021 Partial Pass Paul Burnette Reinspection Incomplete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 07/12/2021 07/12/2021 BLDG-16 Insulation 161625-2021 Passed Paul Burnette Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 07/1412021 07/1412021 BLOG-17 Interior 161886-2021 Partial Pass Paul Burnette Reinspection Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes Monday, March 7, 2022 Page 1 of 2 Ji'". (.c:ity of Carlsbad SPECIAL INSPECTION AGREEMENT B-45 11.e I O[J m_,g_r1J _!i.f?JYiCf;S Building Division 1635 Faraday Avenue 760-602·2719 www.tarlsbadca.gov In accordance with Chapter 17 of the California Building Code the following must be completed when work being per1ormed requires special Inspection, structural observation and construction material testing. Project/Permit CBR2021-0194 -··--2606 Calibri Lane Project Address:._ .. ··-·-·--- A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you am Owner.Builder i:il. (lf you checked as owner-builder you must also complete Seclion B of this agreement) Zack M Tembi Name: (Piesse print·c ___________ _ ----------{f'i,,:,\) (Ml) Mailing Address2606 Calibri Ln. CarlsbadCA92009 Email:ztembi@grnail.~~m ---- Phone: 860-707-5437 ! am: !ill Property Owner □Property Owners Agent of Record UArchitect of Record □Engineer of Record State of California Registration Numbe · -----·--Expiration Date: -·-·········· AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read. understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of special inspections noted op the approved plans and. as required by the California Buildin~ Code. Signature: 2/11121 ________ Date: B. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor I builder I owner-builder. j Contractor's Company Name:_ ./'l'JA'-1. ~ __ Cg,J:,,Q vl<~\,"'-' \NC . Plecise check 1f you are Owner-Builder n Name: \Please print} ~_<-::"\s:(1.c, - ;M,\J Mailing Address: __ _ ~ .()' 0-"'---C__,_A.,__'_._i .,.='-'-\.LI J__j___ Emai!: .-.C-\1~~/Y ___ ~_?_J_ <e _(::f·•)~_< L '<.,.,:,l,'4 _ ______ Phone: "3 S "? '-/'( "-0 '1 t.. (_ State of California Contractor"s License Number:~J_Q"s_ ·i? 3 :.1. (... Expiration Date: cl_ ____ ---~ c --~~~~-~'l.... • ! acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans: • I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official: • I will have in·place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and the distribution of the reports: and • I certify that I will have a qualified person within our ithe contractor"s) organization to exercise such control. • I will provide a final report/letter in compliance with CBC Section 1704.1.2 prior to requesting final ins ecf'on. 8--45 P:::igP. 1 of 1 Rev. 03/20 Carlsbad CBR2021-0194.RC2 3-15-2021 DATE: 3-15-2021 JURISDICTION: Carlsbad ✓• EsG1I PLAN CHECK#.: CBR2021-0194.RC2 PROJECT ADDRESS: 2606 Colibri Lane □ APPLICANT □ JURIS. SET III PROJECT NAME: Addition & Remodel to Create ADU to Tembi Residence ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: Email: n Mail Telephone Fax In Person 0 REMARKS: By: Erich A. Kuchar, P.E. (For A.D.) EsGil Enclosures: ✓• EsG1I DATE: 3-2-2021 JURISDICTION: Carlsbad PLAN CHECK#.: CBR2021-0194.RC1 PROJECT ADDRESS: 2606 Colibri Lane SET: II □ APPLICANT □ JURIS. PROJECT NAME: Addition & Remodel to Create ADU to Tembi Residence D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: D EsGil staff did not advise the applicant that the plan check has been completed. ~ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Zack Tembi Telephone#: 860-707-5437 Date contacted: (by: Mail Telephone Fax In Person 0 REMARKS: By: Erich A. Kuchar, P.E. (For A.D.) EsGil 2-23-2021 Email: no info Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBR2021-0194.RC1 3-2-2021 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. Please make all corrections, as requested in the correction list. Submit THREE sets of plans for residential projects. For expeditious processing, corrected sets can be submitted in one of two ways: 1 . Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. PLANS 1. A reminder that due to Covid-19, the City will not permit counter corrections. Please make sure all the items are satisfied; otherwise, another round of corrections will be necessary. 2. City of Carlsbad requires on the title sheet of plans completed CAP template, city form B-55 be shown. GENERAL RESIDENTIAL REQUIREMENTS 3. Clearly delineate on the plans the limits of the ADU. Is the second floor directly above the ADU part of the ADU? Set of plans delivered did not include the sheet A3. Submit COMPLETE sets next submittal for approval. MISCELLANEOUS 4. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 5. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Carlsbad CBR2021-0194.RC1 3-2-2021 • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ 6. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Erich A. Kuchar, P.E. (For A.D.) at EsGil. Thank you. ♦ • ✓• EsG1I DATE: February 10, 2021 D APPLICANT D JURIS. JURISDICTION: Carlsbad PLAN CHECK#.: CBR2021-0194 PROJECT ADDRESS: 2606 Colibri Lane SETI PROJECT NAME: Addition & Remodel to Create ADU to Tembi Residence D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Zack Tembi D EsGil staff did not advise the applicant that the plan check has been completed. ~ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Zack Tembi Telephone#: 860-707-5437 Date contacted: Mail Telephone 0 REMARKS: By: Abe Doliente EsGil (by: ) Email: no info Fax In Person Enclosures: 1 /26/21 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBR2021-0194 February 10, 2021 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: CBR2021-0194 PROJECT ADDRESS: 2606 Colibri Lane FLOOR AREA: Addition -244 SF Remodel -532 SF REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: February 10, 2021 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad STORIES: 2 HEIGHT: DATE PLANS RECEIVED BY ESGIL CORPORATION: 1/26/21 PLAN REVIEWER: Abe Doliente This plan review is limited to the technical requirements contained in the California Residential Code, California Building Code, California Plumbing Code, California Mechanical Code, California I Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disable_d. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2019 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2019 CRC, 2019 CBC, 2019 CPC, 2019 CMG and 2019 CEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2019 California Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copyl where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. .. • Carlsbad CBR2021-0194 February 10, 2021 Please make all corrections, as requested in the correction list. Submit THREE sets of plans for residential projects. For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. PLANS 1. A reminder that due to Covid-19, the City will not permit counter corrections. Please make sure all the items are satisfied; otherwise, another round of corrections will be necessary. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). Signatures on the final sets of plans will be verified before they are approved. 3. Plans shall have the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation, along with structural calculations. (California Business and Professions Code). Signatures on the final sets of plans will be verified before they are approved. 4. Specify on the title sheet the gross floor area of the new ADU. FIRE PROTECTION 5. Please indicate on the plans whether the existing residence has a fire sprinkler system installed. If so, then provide a note stating that any additions/alterations will be provided with an automatic residential fire sprinkler system. Section R313.2. 6. If this project creates a new dwelling unit 1200 sq ft or larger attached to or within an existing building, then the ENTIRE building must be provided with an automatic residential fire sprinkler system, per Section R313.2. 7. Show on the plans the location of the smoke alarms and the carbon monoxide alarms (whether existing or to be added). Carlsbad CBR2021-0194 February 10, 2021 GENERAL RESIDENTIAL REQUIREMENTS 8. Water closet compartments shall be provided with aggregate glazing area in windows of not less than 3 square feet, one-half of which must be openable (unless mechanical ventilation is provided). Section R303.3. 9. Bathrooms containing bathtubs or showers must be mechanically ventilated (an openable window won't suffice). Section R303.3.1. 10. Clearly delineate on the plans the limits of the ADU. Is the second floor directly above the ADU part of the ADU? 11. Wall assemblies separating main house and the ADU shall be of one-hour fire resistive construction. Provide details of the assemblies. Section R302.3. Such wall assemblies shall extend to the underside of the roof sheathing, where applicable. 12. Is the second floor directly above the ADU part of the ADU? If not, floor assemblies separating the main house and the ADU shall be of one-hour fire resistive construction (½-hour if the building has an automatic sprinkler system). Provide details of the assemblies. Section R302.3. Such assemblies shall extend to and be tight to the exterior wall, where applicable. 13. The supporting construction of fire-rated floor assemblies shall have an equal or greater fire-rating. Section R302.3.1. 14. Provide a note on the plans stating: "Penetrations of fire-resistive walls, floor-- ceilings and roof-ceilings shall be protected as required in CRC Section R302.4." 15. Walls and floors separating the main house and the ADU shall have a sound transmission class (STC) of not less than 50. Additionally, floors must have an impact insulation class (IIC) rating of not less than 50. CBC Section 1207. Show the location of and provide details of the listed wall and floor/ceiling assemblies and indicate the listing agency and listing number for the tested ratings. STRUCTURAL 16. Show shear wall type C with hold down HDU5 at grid line 2 as called out on sheet 8 of the structural calculations. Refer to sheet S1 of the plans. 17. The plans indicate that special inspection will be provided. Please complete the attached City Special Inspection form. Carlsbad CBR2021-0194 February 10, 2021 ELECTRICAL 18. In addition to the notes already shown on the plans, include on the plans the following specifications for electrical devices installed in dwellings: CEC Article 210 & 406 a) Tamper resistant receptacles for all locations described in 210.52 and 550.13.(i.e. all receptacles in a dwelling). b) Weather resistant type for receptacles installed in damp or wet locations (outside). 406.4(0)(6). c) Arc-fault protection for all outlets (not just receptacles) located in rooms described in NEC 210.12(A): Kitchens, laundry areas, family, living, bedrooms, dining, halls, etc. d) GFCI protected outlets for locations described in NEC 210.8(A): Laundry areas, kitchen dishwashers, kitchens, garages, bathrooms, outdoors, within 6' of a sink, etc. 19. For a single-family dwelling unit and for the ADU, show that at least one receptacle outlet accessible at grade level will be installed outdoors at the front and back of the dwelling. CEC Article 210.52(E). This receptacle must be GFCI protected. 20. Per CEC Article 210.11(C)1, note on the plans that there will be a minimum of 2 small appliance branch circuits within the locations specified in Article 210.52(B), i.e., kitchen and dining areas. PLUMBING 21. Specify on the plans: Water conseNing fixtures: New water closets shall use no more than 1.28 gallons of water per flush, kitchen faucets may not exceed 1.8 GPM, lavatories are limited to 1.2 GPM, and showerheads may not exceed 1.8 GPM of flow. CPC Sections 407, 408, 411, 412.Revise note 4 under Green notes to show 1.8 gallons per minute instead of 2.0. RESIDENTIAL GREEN BUILDING STANDARDS In addition to the notes already shown on the plans, include or revise the following notes to comply with the current code. 22. Note on the plans that when a shower is provided with multiple shower heads, the sum of flow to all the heads shall not exceed 1.8 gpm @ 80 psi, or the shower shall be designed so that only one head is on at a time. CGC Section 4.303.1.3.2. 23. Note on the plans that prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions Carlsbad CBR2021-0194 February 10, 2021 from the Green Building Standards Code have been implemented as part of the construction. CGC 102.3. ENERGY CONSERVATION 24. When replacing or modifying the mechanical system: If applicable. o If more than 40' of new ductwork is installed in unconditioned space, HERS inspection is required for both existing and new duct sealing. o Replacement of mechanical equipment (air handler, condensing unit of an air conditioner or heat pump, cooling or heating coil, or the furnace heat exchanger) requires HERS inspection. o Note: The CF1 R-AL T-HVAC form may be submitted at the final inspection, ii is not required at initial plan submittal. MISCELLANEOUS 25. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 26. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ 27. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Error! Reference source not found. at EsGil. Thank you. • Carlsbad CBR2021-0194 February 10, 2021 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Abe Doliente PLAN CHECK#.: CBR2021-0194 DATE: February 10, 2021 BUILDING ADDRESS: 2606 Colibri Lane BUILDING OCCUPANCY: R3/U BUILDING AREA Valuation PORTION ( Sq. Fl.) Multiplier Addition 244 169.50 Remodel 532 46.51 Air Conditioning 244 5.39 Fire Sprinklers TOTAL VALUE Junsd iclion Code cb By Ordinance 1997 UBC Buildin Permit Fee g ... 1997 UBC Plan Check Fee • ';·:.1 Type of Review: Complete Review Reg. VALUE Mod. D Structural Only D Repetitive Fe@ ,.. Repeats D Other □ Ho..ty EsGil Fee ,__ ___ ....,,Hr. @ • Comments: ($) 41,358 24,743 1,315 67,416 $312.551 Sheet 1 of 1 • PCSD Engineering Corp 3529 Coastview Court Carlsbad, CA 92010 Ph: 760-207-1885 Structural Design Calculations Residential Remodel Client Jeff Parshalle Architect P.O. Box 23013 Encinitas, CA 92024 Project Paul . RCE C57182, exp 12131121 January 5, 2021 PCSD File#: 21-010 P'AHt ~•-h,rist~nsl?n ."'>r..n /:'~/.l" Eairinu.ri"1-"f · CITY Paul Christenson San Diego Engineering 3529 Coastview Ct -Carlsbad, CA 92010 Telephone (760) 207-1885 -Email: paul.pcsd@gmail.com 1.0 Design Criteria: Cobas Residence 21-010 Code: Timber: 2019 California Building Code -ASCE 7-16 Douglas Fir-Larch (DF-L), WWPA or WCLIB 2x Wall Framing: DF-L #2 (unless noted otherwise) 2x Rafters & Joists: DF-L #2 " " Posts & Beams: DF-L #1 • " Glue-Lam Beams: Simple Span: Grade 24F-V4 (DF/DF) Grade 24F-V8 (DF/DF) Cantilevers: Sheathing: Min. APA-Rated Sheathing, Exposure 1, Plywood or OSB (U.N.0.) Engineered Framing Wood I-Joists: T JI 110,210,230,360,560 ICC ESR-1153 1.9E Microllam, 2.0E Parallam ICBO ER-4979 Concrete: Concrete Block: Mortar: Grout: LVL, PSL Compressive Strength @ 28 days per ASTM C39-96: Footings: f'c = 2500 psi Grade Beams: f'c = 3000 psi Grade N-I per ASTM C90-95, f'm = 1500 psi per ASTM E447-92 Type S Mortar Cement per ASTM C270-95, Min. f'm = 1800 psi @ 28 days. Coarse Grout w/ 3/8" Max. Aggregate per ASTM C476-91, Min. f'm = 2000 psi @ 28 days. Reinforcing Steel: #4 & Larger: #3 & Smaller: ASTM A615-60 (Fy = 60 ksi) ASTM A615-40 (Fy = 40 ksi) Structural Steel: 'W' Shapes: ASTM A992, Fy= 50-65 ksi Plates, Angles, ChannelsASTM A36, Fy = 36 ksi Tube Shapes: ASTM A500, Grade B, Fy= 46 ksi Pipe Shapes: ASTM A53, Grade B, Fy=35 ksi Welding Electrodes: Structural Steel: E70-T6 E90 Series Bolts: Soils: References: A615-60 Rebar: Sill Plate Anchor Bolls & Threaded Rods: Steel Moment & Braced Frames: 1500 psf Bearing Pressure A307 Quality Minimum A325 (Bearing, U.N.O.) JOB 21-010 SHEET NO 'l.. OF -----?iTU/'{;,f"'r1m,.-,,, dn, ~o bJZheerutJ CALCULATED BY PSC DATE 1/5/21 3529 Coastview Ct-Carlsbad, CA 92010 CHECK BY _____ DATE ___ _ SCALE Telephone (760) 207-1885 -Email: paul.pcsd@gmail.com 2.0 LOAD LIST 2.1 Roof (Vaulted) Roofing 15/32" Sheathing Roof Framing 5/8" Gyp. Bd. Insulation and Misc. Ioc = I1.L = Total Load= 2.2 Roof (w I teiling) Roofing 15/32" Sheathing Roof Framing Insulation and Misc. 2.3 Ceiling Ceiling Joists IoL = I1.1. = Total Load= 5/8" Gyp. Bd. Insulation and Misc. 2.4 Walls Io1. = Ill= Total Load= Exterior Wall 7/8" Stucco 15/32" Sheathing 2x4 Studs @ 16" o.c. 5/8" Gypsum Bd. Misc. 9.0 psf 1.5 psf 2.8 psf 2.8 psf 1.9 psf 18.0 psf 20.0 psf 38.0 psf 9.0 psf Upsf 2.8 psf 1.7 psf 15.0 psf 20.0 psf 35.0 psf 1.3 psf 2.8 psf 1.9 psf 6.0 psf 10.0 psf 16.0 psf 9.0 psf 1.5 psf 1.1 psf 2.8 psf 0.6 psf 15.0 psf Interior Wall 1/2" Gyp. Bd. (2 Sides) 2x4 Studs @ 16" o.c. Misc. 4.6 psf I.I psf 2;3 psf 8.0 psf ?tnd'G"rn.nen.ron -.,,_.f}U/1"' £npfHH'VIJ 3529 Coastvlew Ct -Carlsbad, CA 92010 JOB 21-010 SHEET NO ) OF CALCULATED BY PSC DAT=:E:----:1""'!5"'!2"'1- CHECK BY _____ DATE __ _ SCALE Telephone (760) 207-1885 -Email: paul.pcsd@gmail.com 2.0 LOAD LIST (CONTIN) 2.5 Floor Floor Cover Sheathing 2xF.J. 5/8" Gyp. Bd. Insulation and Misc. IoL = ILL= Total Load= 5.5 psf 2.3 psf 3.5 psf 2.8 psf 0.9 psf 15.0 psf 40.0 psf (60.0 psf -Decks) 55.0 psf WIND PARAMETERS 2.6 Wind Basic Wind Speed = 110 mph Exposure Cat = B Ps = >.Kzt•i*Ps30 (ASCE 7-16 -Equation 28.l-1) P = 26.6 psf P = 16.0 psf (*0.6 -ASD) 2.7 Seismic Sos= 0.829 Sos Cs= (Rfl) Cs= 0.128 USE: V= 0.128 WoL ASD BASE SHEAR V ASD ( 11.4.5) >. = 1.00 (fig. 28.5. I-PsJO = 26,6 psf Kzt= 1.00 (fig.26.8-IJ I= 1.0 USGS APPLICATION Ss= 1.036 s,= 0.401 F = • 1.20 F= V 1.80 R= 6.5 I= 1.00 hn = 25.00 Occupancy Category: 2 Site Class: D SEISMIC DESIGN CATEGORY S1 <0.75 s, > 0.04 Ss>o.1s (11.6 ASCE 7-16) (11.4.2 ASCE 7-16) (fig, 28.5-1) (table 1.5-2) T, = C, • (h,,)°" = 0.224 Ts= S01/S05• 0.481 k= 1.0 Ta< (0.8)Ts, OK Ta<0.5 Seismic Design Category: D PCSD Engineering 3529 Coast:view-Cour:t. , Carlsbad, CA 92010 , (760) 207-1885 I paul.pcsd@gmail.com Project Title: Engineer: Project ID: Project Descr: :,:~C,g,~··:: .~l;§~~~~;: . --/ -.--'" . . -- t I DESCRIPTION: --None-- ••None- Calculations per ASCE 7-16 Risk Category of Building or Other Structure : 'II' : All Buildings and other structures except those listed as Category I, 111, and IV Seismic Importance Factor Max. Ground Motions, 5% Damping : S·s = 1:036 g; 0.2 sec-response· S 1 = 0.4009 g, 1.0 sec response Latitude = Longitude = 33.110 degNorth 117:251" deg West ASCE 7-16, Page 4, Table 1.5-1 ASCE 7-16, Page 5, Teble 1.5-2 ASCE 7-1611.4.2 Confonns to ASCE 7 Section 12.8.1.3: Regular structure with period of 0.5 s or less, SOS limited to max of 0.7'SDS or 1.0 for calculation of Cs. Site Cla11, Site Coeff. and Desi n Cate o = D ASCE 7-16 Table 20.3-1 Site Classiflcation 'D' : Shear Wave Velocity 600 to 1,200 fl/sec Site Coefficienls Fa & Fv Fa Fv = 1.20 ASCE 7-16 TabJe 11.4-1 & 11.4-2 (using straight-line interpolstion from table values) Maximum Considered Earthquake AooeleraUon Design Spectral Aooeleration Seismic Design Category .. n.i...t~lf · 'Clu""'6ffl•,;_ , · ·' -,'--""'!!!"-'l ng. .. ,~•!'!' .. :~ ,,_ s MS= Fa. Ss S M1 = Fv 'S1 = 1.80 = 1.243 = 0,722 = 0.829 = 0.481 D ~IC Seismic FOrce Resisting System ... Bearing-Walt Systems- 15.Llght-frame (wood) walls sheathed wlwood structural panels rated for shear mlstance. Response Modification Coefficient • R ' System Oversttength Factor • Wo • Deflection Amplification Factor • Cd • NOTE/ See ASCE 7-16 for all applicable footnotes. 6,50 Building height Limits : 3.00 Category 'A & B' Limit: Category ·c• Limit 4.oo Category 'D' Limit: Category 'E' Limit Category 'F' Limit: No Limit No Limit Limit= 65 Llmlt=65 Limit =65 Equival&nt ·Lateral Force Procedure • · · ocedure' is being used according to the provisions of ASCE 7-16 12.8 -,,~rn,Ji:,i'BUl{dln Structure Type for Building Period Calculation : Ail Other Structural Systems • Ct· value 0.020 • hn ' : Height from base to highest level = 33.0 ft • x • value 0.75 ·Ta • Approxlmate fundamental period using Eq. 12.8-7 : Ta= Ct • (hn • x) = 0.275 sec 8.000. sec 'TL': l,ong:period transition period per ASCE 7-16 Maps 22-14-> 22-17 S os Short Period Design Spectral Response = • R • : Response Modification Factor = • I • : Seismic Importance Factor = Building Period ' Ta• Calculated from Approximate Method selected 0.829 6.50 1 From Eq. 12.8-2, Preliminary Cs From Eq. 12.8-3 & 12.8-4 , Cs need not exoeed From Eq. 12.8-5 & 12.6-6, Cs not be less than Userhn 1ellffld ASCE 12.8.1.3 : Regvlarsmic(ure, c,: Seltmfc Response Coefficient = Less than 5 Stories and with T «• 0.5 sec, SO St <• 1.5 for Cs calcutatlon ASCE 7-16 Eq. 11.4-1 ASCE 7-16 Eq. 11.4-2 ASCE 7-16 Eq. 11.4-3 ASCE 7-16 Eq. 11.4--4 ASCE 7-16 Table 11.6-1 &-2 ASCE 7-16 Table 12.2-1 ASCE 7-16 Section 12.6.2 Use ASCE 12.8-7 = 0.275 sec ASCE 7-16 Section 12.8.1.1 = 0.128 = 0.269 = 0.036 = 0.1275 ... 0 MEMBER REPORT Floor Framing, (FB-1) Ar Bm 1 plece(s) 31/2" x 11 7/8" 2.2E Parallam® PSL Overall length: 1S' 9" PASSED ♦ 0 All locations are measured from the outside race cl left support ( or left cantllever end). All dimensions are horizontal. .;..:.,; ,-..1 :),'-.-C ~i~ ;,<>( .,,~~ !#ii,-.,, 'hmlo'~'"':> i.t'fu:· -·· Member Reaction l1bs) 3750 @2" 7656 (3.50") Shear (lbs) 3064@ 1' 3 3/8" 8035 Moment (Ft·lbs) 12515 @ 7' 1/16" 19902 Live Load Def!. (In l 0.342@7' 5" 0.514 Total Load oen. (In) 0.492@ 7' 5" 0.771 • Oetlecllon c:rtter1a: LL (l/360) and 11. (l/2~), • Al owed moment does not reflect the adjustment for the beam stability factor. Bot!Dm Edge (Lu) 15' 9' 0/C •Maximum alowable bracing lnmval• based on applied load, ,'..If.I~ -_~ ...... ~ ~_;;;{,~~~;:i•' ';'t~;~-;- Passed ( 49%) -- Passed (38%) 1.00 Passed (63%) 1.00 Passed (L/542) -· Passed (L/376) .. '.,._v; ',_., "1 • -,,, .,,. '>,, 1.0 D + 1.0 L (All Spans) 1.0 D + 1.0 L (All Spans) 1.0 D + 1.0 L (All Soans) 1.0 D + 1.0 L (All Spans) 1.0 D + 1.0 L (All Spans) tKi-ti}.S-,.11f·:i:~r 1-\ Systl!m:Floor Member Type : Drop Beam BulldlnO Use : Residential BulldlnO Code : IllC 2018 Design Mett,odology : ASD w~ wamints tllat the sizing of Its products wlU be In accordance with Weyemaeuser product design oiterta and published design values. Weyerhaeuser expressly disclaims any other WMJntles related to the software. Use or this software ts not Intended lXl drcum-.ent the need rcr a design professional as determined by the au!honty having Junsdk:tion. The design..-of record, builder or framer ts responsi~ lXl assure lhat this calculatlon Is compatible with the 0\/e'illl project. Accessones (Rim Board, Sloddng Panels and Squash 81ocks) are not designed by this software. Products manufactured at Weyerhaeuser factUties are third-party certified lXl sustalnable forestry stllndards. weyerhaeuser Engineered Lumber Products have been eYaluated by rec-ES unOer eYaltsatfon reports fSR· 1153 and fSR· 1387 Md/or tested In acxordance with allf)focable AS™ standards. For current code evaluatlon repon:s, Weyerl,aeoser product Ullerature and tnstallatlon details me, IX> WWW .weyerhaeuser.oom,'woodproduct5/document·llbrllry. The product appllcatlon, Input design loads, dlmension5 and support lnfo<maUon have been provided by ForteWEB Software Operatllr f'Or11eWl!I Softw■N 0panltDr Job NOll■I Paul o,n~son PCSO Enoneertng (760) 207-1885 paul.pcsd@omaU.com A W<yerhaeu,.,, 1/10/2021 3:02:29 PM UTC ForteWEB v3.l, Engine: VS.1.5.1, Data: V8.0.1.0 FIie Name: Cobas Pagel/1 '-ilFORTE·m 0 MEMBER REPORT Floor Framing, (FB-2) Ar Bm 1plece(s)31/2" x 11 7/8" 2.2E Parallam® PSL Overall Length: 6' 1 o· All tocatlOns are measured from the outside face r:J left support ( or left cantilever end). All dlmenSk>ns are horlzontal. 1.0 0 + 1.0 Shear lbs 595@ 1' 3 3/8" 1.00 1.0 0 + 1.0 Moment (Ft·lbs) 1473@3' s· 19902 1.00 1.0 0 + 1.0 uve Load oen. In 0.010 @3' 5" 0.217 1.0 0 + 1.0 Total Load Def!. In 0.014@3' S" 0.325 Passed (l/999+ • Defledlon Cffteria: LL (l/360) and TL (1./240). • Alowed moment does not reflect the adjustment for the beam stabltity fllctcr. •Ma>dmum alowable bracing lntllrvals based on applied lead. I • Uniform (PSF) PASSED 0 System : Aoor Member Type : Drop Beam 8ulldlng use : Resldentlal Bulldlng Code : lBC 2018 DeslQrl Me1hodology : ASD w~ warrants that the Slzlng of Its products will be In accordance with Weyerhaeuser product design Cffteria and published design values. Weyemaeu,er expressly dlsdalms arry other wz,mintles reltted to the soltwere. Use of this software Is not In-to circumvent the Med for a design professlonal as dell!rmlned by the authority having jurisdiction, The designer of record, builder or framer Is responsible to assure that this calaJlatlon Is compaUble with the CMrall project. Aa:essones (Rlm Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufac11Jlt,d at W~ t'adlltles att third-party certified to sustalneble forestry standards. Weyerheeu$er Engineered Lumber Products have been evaluated by lCC·ES under evaluation reports ESR-1153 and ESR-1387 -ar,d/or tesled In aooonlana! wnt, •~~ ~ standards. For curreit <X><le l!Yaluallon rel)OltS, Weyetiaeuser product 1111era11Jre anc! 1nstlllla11on ~• refer to www.weyertlaeuser.CXlll1/woodproducts/document4lbrary. lhe product appltcation, Input desli,, loads, dlmenstons and support Information have been provided by ForteWEB Software ~!Dr Folte-■ Saftwara Opentrw .JobNoqs Paul Olllstenson PCSO Englneenng (760) 207-1885 A pauf,l)CSd@OmaU.com ~rlucuser 1/10/2021 3:01:35 PM UTC ForteWEB v3,l, Engine: VS.1.5.1, Data: VS.0.1.0 File Name: Cobas Page 1 / 1 JOB SHEeTNO· 21-010 S:: OF ___ _ ?11ULf;Ad.dea,o:11-~~o- bJUleerlnJ CALCULATED BY PSC DATE 1/5/21 CHECK BY DATE -------3529 Coastview Ct -Carlsbad, CA 92010 SCALE Telephone (760) 207-1885 -Email: paul.pcsd@gmail.com S.O Lateral Design & Analysis (Two-Story) Wind: P = J.. Kzt I pS30 (ASCI! 7-16 -Equation 285-1) Seismic: V = C1 WoL (ASCE 7-16-Eqo 12.8-2) A= 1.00 Kzt = 1.0 PS30= 26.6 psf s.= 1.036 Fa= 1.2 R = 6.50 s,= 0.401 Fv= 1.8 1-1.00 I = l.O (fig 28 S 1-1) (Ilg 26 8) (fig. 28 S-11 (tAblc I 5-2) V = 0.091 •Wt• p (p -Redundancy) P= 16.0 psf Criteria Each Story Resists > 35% Base Shear: Wind Loads Any Shear Wall wt (h/I)>1.0 Is < 33% Story Force: P = 16.0 psf x Trib Area Roof Level Direction: Direction: 2nd Floor Level Direction: Direction: Roof Weight Roof Wt. = Exterior Wall Wt = Interior Wall Wt = Ceiling Wt = Floor Weight Diaphragm = Exterior Wall Wt = Interior Wall Wt = 1st Flr. Roof Wt. = N I S = 16.0 12sf X 533 sci: ft.= EI W = 16.0 psf X 544 sq. ft.= N I S = 16.0 psf X 525 sq. ft.= EI W = 16.0 psf X 697 sq. ft.= 15.0 psf x 2552 sq. ft.= 38280 lbs. 15.0 psf x 741 sq. ft.= 11115 lbs. 8.0 psf x 622 sq. ft.= 4976 lbs. 3.0 psf x 2126 sq. ft.= 6378 lbs. ------Total Trib. WR = 60749 lbs. 15.0 psf X 2126 sq. ft. = 31890 lbs. 15.0 psf X 1545 sq. ft. = 23 175 lbs. 8.0 psf X 1233 sq. ft . = 9864 lbs. 18.0 psf X 544 sq. ft. = 9792 lbs. TotarTrio. WR= 74721 lbs. Total Seismic Dead Load: Wt = 135470 lbs. ASD Base Shear: V = 0.091 *Wt= 12338 lbs. 8507 lbs. 8682 lbs. 8379 lbs. 11124 lbs. p = 1st Story 2nd Story satisfied satisfied satisfied not satisfied I 1 JOB 21-010 SHEET NO (, OF ----~.u/r;;;d.dfm,gm_ e£rn_ 2f"'J" bfaeerbtJ CALCULATED BY PSC DATE 1/5/21 CHECK BY ____ DATE __ _ 3529 Coastview Ct -Carlsbad, CA 92010 SCALE Telephone (760) 207-1885 -Email: paul.pcsd@gmail.com Roof Diaphragm: N I s Direction E /W Direction· V = 8507 lbs. V= 8682 lbs. sq. ft A= 2552 sq. ft psf f =V/A= 3.40 psf p A = 2552 .,,.,...,.---~:,-,,---f =V/A= 3.33 p ------ Floor Diaphragm: N I s Direction E /W Direction V= 8379 lbs. V= 11124 lbs. A= 2670 sq. ft A= 2670 sq. ft fp=V/A= 3.14 psf f =V/A= p 4.17 psf Seismic Lateral Distribution V = 12338 lbs. • p F V Level Wx h x k w. (h. l (lbs) (lbs-ft) 1', w-hk (lbs) (lbs) Roof 60749 19 1154231 0.632 7796 7796 2nd Floor 74721 9 672489 0.368 4542 12338 1826720 1.000 12338 ? .u/f:r~ :Int ot,;!l'o £n.P"ee,..,,J 3529 Coastview Ct-Carlsbad, CA 92010 Telephone (760) 207-1885-Email: paul.pcsd@gmail.com 5.2 Lateral Design & Analysis -1st Story Shear Walls N /S JOB SHEET NO CALCULATED BY 21-010 -:)_ OF Psc oAT-e--1-,s-,2-1- oATE CHECK BY SCALE ------- E /W Gridline Length of Shearwalls Total Wall Ht. Type Gridline Length of Shearwalls Total Wall Ht. Type 0 #~V/0! 2 7 5 11.5 8 D 0 #Dl}'/0! 0 0 #0 V/0! 0 0 #0 Y/0! 0 0 0 #DI VO! 0 0 #0 /0! 0 #DJ /0! 0 #D /0! 0 #OJt:0! 0 #DI /0! 0 #[~ /0! 0 # V/0! 0 #~ IV/0! 0 #D /0! 0 #~/0! ' ,. ... , Gfvi,t,K-S..,.,::,;,,,, ::..,, .... ....., ? ,u/f;',t~h ;In, .iX-~o bfaeerutJ 3529 Coastview Ct -Carlsbad, CA 9201 0 Telephone (760) 207-1885 -Email: paul.pcsd@gmail.com 5.2 Lateral Design & Analysis ( cont.) Gridline CD 33 % ( 11124 X 0.33 3671 # ) 3671 lbs.+ 3647 y = 11.5 ft. 636 plf . • ~3ueF ,.1. OTF 5091 lbs. 1.Ul.O JOB 21-010 SHEET NO q, OF CALCULATED BY PSC DATE 1/5/21 CHECK BY DATE SCALE ~ HDUS ~;m/f;,f'~_ ef.m_.z>'~~ bfaeerutJ 3529 Coastview Ct -Carlsbad, CA 92010 Telephone (760) 207-1885 -Email: paul.pcsd@gmail.com 6.0 FOUNDATION DESIGN 6.1 CONTINUOUS FOOTING w = 1125 plf width = 1125 plf 1500 psf 0.75 ft (MIN.) => 9 INCHES (MIN.) ( E) rs-,. WIDE CON TIN. FTG W / 1 -# 4 TOP AND BOTTOM & EMBED. 18 " INTO UNDISTURBED SOIL (MIN.) 6.2 MAX POINT LOAD ON FOOTING JOB 21-010 ~ OF , PSC DAT-E--1-/5-/2_1 _ SHEET NO· CALCULATED BY CHECK BY SCALE ____ DATE __ _ ASBP = 1500 psf P .u = 1500 • ~ • ~ 12 12 Pan = 7500 lbs , I ------·---· -. - STORM WATER POLLUTION PREVENTION NOTES 1. ALL NECESSARY EQUIPMENT ANO MATERIALS SHALL BE AVAILABLE ON SITE TO FACIUTATE RAPID INSTALLATION Of EROSION AND SEO!MfNT CONTROL BMPs WHEN RAIN IS EMINENT. 2. THE O'NN£R/CONTRACTOR SHALL RESTORE ALL EROSION CONffiOl DEVlCES TO WORKING ORDER TO THE SATISFACTION OF THE CITY INSPECTOR AFTER EACH RUN-Off PROOUONG RAINFALL 3. TI-IE O'NNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY 8[ REQUIRED BY TT,[ QTY INSPECTOR DUE TO INCOMPLETE GRADING OPERAT!ONS OR UNf'OO:ESEEN C!RCUMST ANCfS 'M,JICH MAY ARISE. 4 ALL REMOVABLE PROTECT1\IF DEVICES SHALL BE IN PLACE AT THE END or EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PlCENI ( 40%). SILT AND OTHER DEBRIS SHALL BE R£MOvtD AF1ER EACH RAINFALL 5. ALL GRAVEL BAGS SHALL CONTAIN 3/4 !NCH MIN!MUM AGGREGATE 6 ADEQUATE EROSI~ AND SEDIMENT CONTROL AND PfRIMETER PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUS I !:lE !NSTALLEO AND '-IAINTAINEO. 7. THE CITY INsPECTOR SHALL HAVE THE AUTHORITY TO AlltR rnts PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED TO ENSURE COMPLJANCE WITH CITY STORM WATER QUALITY REGULATIONS. _Q'-!'NIR'S CERTIFICATE: I UNDERSTAND ANO ACKNOV!lEDGE TiiAT l MUST: (I) IMPLEMENT BEST MANAGE!i!ENT PRACTICES (BMPS) DURING COOS1RUCTION ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO AVOID TiiE MOBIUZATION or PCU.UTANTS SUCH AS SEDIMENT AND TO AVOID THE EXPOSURE Of STORM WATER TO CONSTRUCTION RELATED POLLUrANTS; ANO {2) ADHERE TO, ANO AT All TIMES, COMPLY 'MTH Tl,1$ CITY APPROVED TIER 1 CONSTRUCTION SWPPP THROUGHOUl THE DURATION Of TH[ CONSTRUCTION ACnVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETE ANO Af'PROVED BY THE CITY Of CARLSBAD. ,)t£1"p f',4/!.J;!/lt,,.c.· !f;:.,c..:/1 f77:t.f OWl'JERW/Q)'!Nfjrs AGENT)p;iJt -~INT) ~::17 -,,,,,,,,~ ~ (sJ)iiP1rnfs?iG6n NAt.tE (s1GNATIJRE} E-29 ,f ,;,' l-1 ~- STORM WATER COMPLIANCE FORM TIER 1 CONSTRUCTION SWPPP BEST MANAGEMENT RRACT!CES (BMP) SELECTION TABLE ::_, &R-Jc ·;,,1 {;!'I'{ ~-~- Eros1011 Centro Sed<rneot Colllrul EIMPs Traci<ing Nort-St>rrn Water Waste Management and Matenals "'" Conlroi EIMPs Managemetit BMPs P~h.Jtioo Control fJMPs -- .Q a .Q 0 1l g ~ t ' § ~ 0 -6 6 • ~ .& 6 j • ,, ~ ~ . " Oo ~ • _E " t • fl co :S ~ g: s Best Management Practice• .. r O o ;e ·~ -~ -~ 8 ~ " • 8~ oJ: .e ts i 0 ~ ~ .e &; (BMPJ Description ➔ ] t . °' ; °' : ~-§ 8~ "• 6 ~ 0 B :g, e I a "' ; i'I 1)>e_ ]i 5§ •• . ~ 2 E ] " a J ~ _g E ~ ~~ o,+' :ls ];i~ 0 J ~i ;< i. 0 il ~ ~ E'§ •e j g f~ j § 2e }~ JJ] -~ ~ E ~§ ~ ,l! ~ .!:a g ~~ -o ~ 6 io:: J:6 (t_ jiii "'a ~ 0 ~> = ~o ~~ " ~ ~u ~" CASQA Desigiatk,n ➔ N ~ ~ ~ 0 ~ ~ ~ ~ 0 N ~ N ~ ' N ~ 0 ~ ' ' ' ' ' ' ' ' ' ' ' ' ' ' •i" ' ' ' ' ' ' ' u u :, ~ w :,; w :,; w w w :,; I' ~ ~ ~ ~ ~ i ii' i i I Conwuction Adi""" w w ~ ~ ~ ~ ~ N z z z z Grodin" /Soil Disturbance frenchinn ~ XCCVlltion v St ijino Orillin Ofin<I Concrete/Asot,olt Sowcutt.ina Concrete FlotwOf'I< Po~no Conduit · e Installation Stucco/Mortar Work Woste Oisoosal V Star.in~ 11 0" Down Areo ~ Eoui"ment Mointenonce and Fuelina Hazardous Substance Use/Stora"e Oewoterif!<I i Sile Access Aero!;!; Dirt i ' Other /listl: i ' -Instructions; 1. Check the box lo the left of oH applicable construction octi'Aty {first column) expected to occur during construction 2. located along the top of the BMP foble is a list of BMP's with it's corresponding Colilomio Slorrn•aler Quality Association (CASQA) designation n_ umber. Choose one Of" mrne BMPs _'IOIJ inl:end to use during construction from the list Checl,: the bo~ 'llhere the chosen activity row ;ntersects with the BMP column J. Refer to the CASQA construction handbook for information ond details of the chose,, BMPs and how to ap~y them to the project PROJECT INFORMATIO_N_ Slte Address: ic,,o,;;e W,)1,1{1t:,,, £,,/I-NC . ~ !~ l! ;;! g oo IC> ~ ' ii Assessor's Parcel Number: ')r4 ' £}-/ -CT ,;:, Emergency Contact: Nome: ZA-c'"-tl:'P!I}; 24 Hour Phone: fl6£_--7:..L:.._5f_1:,_.?,_? __ Construction Threot lo Storm Weter Otlolity (Checi< Bo~) 0 t.lED!UM J;1 LOW . • o-;< • ~i • 0 CC 0 0 u, ~ ' I V ~ -C- Page 1 of 1 REV 11/17 Carlsbad Climate Action Plan Trigger Sheet Plan Check Number:C."i;is22:2J-OiCZlf Valuation: {cG) {p (,.17 1. Does this project have an electric panel upgrade: Yes 1€) Triggers: • New residential (1-2 family dwellings and townhouses with attached garages): If the plans show an electric panel upgrade they need to show details for 1 "EV Ready" EV charging system. o Panel capability, dedicated branch circuit, minimum 40A 2-pole breaker, 1" raceway, No. 8 conductors and receptacle installed to the anticipated charger location. 2. Is EV charging Applicable: Yes / GJ Triggers: • Newly constructed SF residential building: Plans need to show details for 1 "EV Ready" charging system for each unit. o Panel capacity, dedicated branch circuit, minimum 40A 2-pole breaker, 1" raceway, No. 8 conductors and receptacle installed to the anticipated charger location. • SF residential addition and/or alteration: With valuation of $60,000 or more OR an electric panel upgrade need to show details for 1 "EV Ready" charging system. o Panel capacity, dedicated branch circuit, minimum 40A 2-pole breaker, 1" raceway, No. 8 conductors and receptacle installed to the anticipated charger location. • Newly constructed multi-family building: (more than 2 dwelling units). Plans need to show 10% of parking to be EV spaces and 50% (of the 10% EV spaces) to be "EV Installed" spaces. The remaining 50% may be "Capable, Ready, or Installed". o Accessible EV installed spaces per CBC 11B-Table 228.3.2.1. o Single space must be a van accessible EV installed space (if it is a common area parking stall). o Refer to CMC 18.21.140 for stall dimension updates made to 4.106.4.2.2. • Multi-family additions and major alterations: With valuation of;,: $60,000 AND including: removal of interior finishes; significant upgrade to structural and mechanical, electrical and/or plumbing systems; and significant site work requiring a grading permit. Plans need to show 10% of parking to be EV spaces and 50% (of the 10%) installed spaces. The remaining 50% may be "Capable, Ready, or Installed". o Accessible EV installed spaces per CBC 118-Table 228.3.2.1. o Single space must be a van accessible EV installed space (if it is a common area parking stall). o Refer to CMC 18.21.140 for stall dimension updates made to 4.106.4.2.2. • Newly constructed Hotels/ Motel: EV parking per CMC updated Green Code Table 4.106.4.3.1. (10% EV spaces and 50% (of the 10% EV spaces) to be "EV Installed" spaces. • Newly constructed commercial and industrial buildings: Plans need to show 10% of parking to be EV spaces and 50% (of the 10%) to be "EV Installed" spaces. The remaining 50% may be "Capable, Ready, or Installed". o Accessible EV installed spaces per CBC 11B-Table 228.3.2.1. o Single space must be van accessible EV installed space. 3. Was an EV Hardship/ Exemption Approved: Yes /~2J o See Carlsbad Municipal Code section 1lti'i.140 (CGBSC section 4.106.4 exception 4). 4. Provide the applicable EV parking stall count below: • EV Total Spaces: • Number of EV Capable: __ _ • Number of EV Ready: ___ (single family new constn.,ction, additions and alterations} • Number of EV lnstaded: ___ (rnLdti-fam1ly and comrnercia, new construction) 5. Energy Efficiency Applicable: tfj I~ Triggers: • Single Family AND Multi-Family additions and alterations with valuation of $60,000 or more. CMC18.30.190 • Newly constructed Commercial and Industrial buildings. CMC18.21.155 • New hotels/motels and high-rise residential construction. • Commercial alteration with valuation of $200,000 or more. o If valuation of $1,000,000 or more AND affecting 75% or more of existing floor area or addition of 2,000sf of new roof area see CMC 18.30.130 for solar tradeoff. • Commercial addition of 1,000sf or more. 6. Photovoltaic System Applicable: Yes I rf.~ PV Size in KW DC __ _ Triggers: • Newly constructed low-rise residential buildings. (CEC section 150.1 (c)14). • Newly constructed high-rise residential and hotel/motel buildings are subject to the non-residential PV requirements for new commercial buildings. o Projects with an electric heat pump shall increase the PV system size by .3kWdc if PV offset option is selected. • Newly constructed commercial and industrial buildings. • Commercial alteration with valuation of $1,000,000 or more AND affecting 75% or more of existing floor area see CMC 18.30.130. • Commercial addition that increases the roof area by 2,000sf or more. 7. Water Heating Applicable: Yes / ~ Triggers: • New Single and Multi-Family residential construction. • Newly constructed Commercial and Industrial buildings. Choose between 3 options. (CMC 18.30.150) 8. Transportation Demand Management: Esgil is not responsible for reviewing TDM. I I /L_. Plan Reviewer:----~~-/---------- ? /--2-?uL( Date: _________ _ f (___ City of Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of permits are not required to fill out this form ❖ Patio I ❖ Decks I ❖ PME (wlo panel upgrade) I ❖ Pool _. If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. _. Details on CAP ordinance requirements are available on the city's website. _. A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and down load the latest form. Project Name/Building Permit No.: Property Address/APN: Applicant Name/Co.: Applicant Address: Contact Phone: 215-534-07-00 Zack Tembi 2606 Colibri Lane 860-707-5437 Contact Email ztembi@gmail.com Contact information of person completing this checklist (if different than above): Name: Company name/address: Jeff Parshalle P .0. Box 230132 Applicant Signature: , W. B-50 Contact Phone: 619-985-4099 Contact Email: jeff@ j parch. net Date: _/_ • .,_/.,_</_-_;:..;.,_y_· __ _ Page 1 of 6 Revised 06/18 City of Carlsbad Climate Action Plan Consistency Checklist Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For alterations and additions to existing buildings, attach Building Permit Valuation worksheet. Building Permit Valuation (BPV) from worksheet: $ {JO, f1 (,/ 7. -- Construction Type I ~ Sedion(s) I Nalls: ~idential □ New construction □ Additions and alterations: D Electrical service panel upgrade onl □ BPV ;a, $200,000 D Nonresidential □ New construction □ Alterations: □ BPV" $200,000 or additions" 1,000 square feet □ BPV ;a, $1,000,000 □ " 2,000 sq. ft. new roof addrtion Checklist Item A hig~ residential building is 4 or more stories, induding a Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor 2A, 3A, 4A N/A 1A, 4A' 1B, 2B, 3B,4A NIA 4A area is residential use All residential additions and alterations 1-2 family dwellings and townhouses with attached garages only 'Multi-family dwellings only where interior finishes are removed 1 B, 4A • and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed 1B, 2B, 3B, 4B and 5 1B, 5 18, 2B, 5 Building alterations of" 75% existing gross floor area 2B,5 1B also applies~ BPV" $200,000 _Check the iwoiriate boxes, expai al rot applcalie nl exceptioo items, aid pruwle~ ea:tlaions ;nl docunenlalioo as necessllY, Please refer t Carlsbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building Standallls Code (CALGreen) for more infonmati v.ilen completing this section. A ■ R dential addition or alteration ~ $60,000 building pennit valuation. ee CMG section 18.30.190. Year Built Single-family Requirements □ Before 1978 Select one: □ DJct sealin!I □ Attic insuation □Cool roof □ 1978 and later Select one: □ Lighting package □Water heating Package □ Between 1978 and 1991 I 1992 and later 0 NIA ________ _ O Exoeption: Home energy score~ 7 (attach certification) Multi-family Requirements □ Altic insulation Select one: ODJdseaijM □Altic insiJation □Cool roof Select one: □Lighting package □Water heating package B. D Nonresidentiar new construction or alterations ~ $200,000 building pennit valuation, or additions~ 1,000 square feet □ NIA Updated 8/15/2019 2 City of Carlsbad Climate Action Plan Consistency Checklist See CMC 18.21.155 and CALGreen Appendix AS, Division A5.2-Energy Efficiency. A5.203.1.1 Choose one: □ .1 Outdoor lighting □ .2 Warehouse dock seal dOOIS □ .3 Restaurant service water heating (comply 111th California Energy Code section 140.5, as amended) O NIA __________ _ □ .4 Daylight design PAFs □.S Exhaust air heat recovery A5.203.1.2.1 Choose one as applicable: 095 Energy budget 090 Energy budget □ NIA A5.211.1" D On-site renewable energy □NIA A5.211.3" D Green power r~ offered by local utility provider, 50% rrinimum renewable sources) □ NIA A5.212.1 D Elevators and escalators □ NIA A5.213.1 D Steel framing □ NIA • lndudes hotels/motels and high-rise residential buildings " For alterations ~ $1,000,000 BPV and affecting > 75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply 111th CMG 18.30.130 instead. 2. Photovoltaic Systems A. D Residential new construction (for l<>W-fise residential building pennlt applications submilled after 1/1/20~ Rererto 2019 California Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic requirement (28 below} instead. 2) If project includes instaHation of an electric heat pump water heater pursuant to CMC 18.30.150(8) (high-rise residential} or 18.30.170(8) (low-rise residential), increase system size by .3kWdc if PV offset option is selected. Floor Plan ID (use additional CFA #d.u. Calculated kWdc' sheels if necessary) Total System Size: kWdc = (CFAx.572) / 1,000 + (1.15 x#d.u.) 'Formula calculation 111here CFA = conditional floor area, #du= number of dwellings per plan type If proposed system size is less than calculated size, please explain. Exception D D D D kWdc B. D Nonresidential new construction or alterations ~$1,000,000 BPV and affecting ~75% existing floor area, or addition that increases roof area by ~2,000 square feet Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to high-rise residential and hotel/motel buildings. Choose one of the following methods: D Gross Floor Area (GFA) Method GFA: Off< 10,000s.f. Enter: 5 kWdc Min. System Size: 011 ~ 10,000s.f. calculate: 15 kWdc x (GFA/10,000) ** kWdc **Round building size factor to nearest tenth, and round system size to nearest whole number. D Time-Dependent Valuation Method Updated 8/15/2019 3 City of Carlsbad Climate Action Plan Consistency Checklist Annual TDV Energy use:••• ______ x .80= Min. system size: ____ _ kWdc '*'Attach calculation documentation using modeling software approved by the California Energy Commission. 3. Water Healing A. D Residential and hotel/motel new construction Please refer to CMC sections 18.30.150 and 18.30.170 when completing this section. D For systems serving individual dwelling units choose one: D Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) D Heat pump water heater AND PV system .3 kWdc larger than required in CMC section 18.30.130 (high rise residential hotel/motel) or CA Energy Code section 150.1(c) 14 (low-rise residential) D Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher D Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors ■ Exception: Project utilizes an existing water heater D For systems serving multiple dwelling units. install a central water-heating system with all of the following: D Gas or propane water heating system D Recirculation system per CMC 18.30.150(8) (high-rise residential, hotel/motel) or CMC 18.30.170(8) (low- rise residential) D Solar water heating system that is either: D .20 solar savings fraction D .15 solar savings fraction, plus drain water heat recovery □Exception: 8. D Nonresidential new construction Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section. D Water heating system derives at least 40% of its energy from one of the following (attach documentation): D Solar-thermal D Photovoltaics D Recovered energy □Water heating system is (choose one): D Heat pump water heater □ Electric resistance water heater( s) □Solar water heating system with .40 solar savings fraction D Exception: Updated 8/15/2019 4 r;h, of Carlsbad Climate Action Plan Consistency Checklist ' "' 4. Electric V• hicle Charaina A 0 Res dential New construction and major alterations* Please J •fer to Carlsbad Ordinance CMC section 18.21.140 when comnWina this section. on.I and two-family residential dwelling or townhouse with attached garage: r ~ Qne EVSE Ready parking space required D Exception : --r Multi-family residential: D Exception : Total Parking Spaces EVSE Soaces Proposed Caoable I Readv Installed 1 Calrulations: Total EVSE spaces = .10 x Total parking (rounded up to nearest "11ole number) EVSE Installed = Total EVSE Spaces x .50 (rounded up to nearest "11ole number) EVSE other= Total EVSE spaces-EVSE Installed (EVSE other may be "Capable," "Ready" or "Installed.") Total 'Major alterations are: (1) for one and two-family dwellings and townhouses v.ith attached garages, alterations have a building permit valuation~ $60,000 or indude an electrical sennce panel upgrade; (2) for multifamily dwellings (three units or more v.ithout attached garages), alterations have a building permit valuation~ $200,000, interior finishes are removed and significant site work and upgrades to structural and mecnanical, electrical, and/or plumbing systems are proposed. B D Nonresidential new construction (includes holels/rnob!ls) D Exception · Total Parking Spaces EVSE Soaces Proposed Caoable I Readv I Installed I Total 7 I I Calculation· Refer to the table below- Total Number of Parkina Soaces orovided Number of reauired EV Soaces Number of reauired EVSE Installed Soaces □ 0-9 1 1 □ 10-25 2 1 □ 26-50 4 2 D 51-75 6 3 □ 76-100 9 5 101-150 12 6 151-200 17 9 201 and over 1 O nercent of total 50 oercent of Reauired EV Soaces Updated 8/15/2019 5 City of Carlsbad Climate Action Plan Consistency Checklist 5. D Transportation Demand Management (TI)M): Nonresidential ONLY An approved Transportation Demand Management (TDM) Plan is required for al nonresidential projecis that meet a 1hreshold of ~enerated ADT. City staff Y.iU use the table below based on your subnitted plans to detemine whether or nor your perm! requires a TDM plan. If TDM is appicable to your perm~, staff will contact the appicant to develop a site-specific TDM plan based on the pennit details. Acknowledgment: Employee ADT Estimation for Various Commercial Uses Office ( all), 20 Restaurant 11 Retail, 8 Industrial 4 Manufacturing 4 Warehousin 4 1 Unless otherwise noted, rates estimated from /TE Trip Generation Manual, 10'hEdition 13 11 4.5 3.5 3 1 , For all office uses, use SAN DAG rate of 20 ADT/1,000 sf to calculate employee ADT 3 Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration Sample calculations: Office: 20,450 sf 1. 20,450 sf/ 1000 x 20 = 409 Employee ADT Retail: 9,334 sf 1. First 1,000 sf= 8 ADT 2. 9,334 sf -1,000 sf= 8,334 sf 3. 8,334 sf/ 1,000 x 4.5 + 8 = 46 Em lo ee ADT I acknowledge that the plans submitted may be subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should my permit require a TDM plan and understand that an approved TDM plan is a condition of permit issuance. Applicant Signature: _________________ _ Date: ______ _ Person other than Applicant to be contacted for TDM compliance (if applicable): Name(Pnnted): _________________ _ Phone Number: _____ _ Email Address: __________________ _ Updated 8/15/2019 6