Loading...
HomeMy WebLinkAbout1923 CALLE BARCELONA; 149; CBC2020-0407; PermitPERMIT REPORT {_ City of Carlsbad Commercial Permit Print Date: 01/11/2022 Permit No: CBC2020-0407 Job Address: 1923 CALLE BARCELONA, # 149, CARLSBAD, CA 92009-8458 Status: Closed -Fina led Permit Type: BLDG-Commercial Work Class: Tenant Improvement Parcel#: Valuation: Occupancy Group: #of Dwelling Units: 2550120400 Track#: $93,020.00 Lot#: Project#: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Project Title: Description: JIM BOS: 2,000 SF RETAIL TO RETAIL (GROCERY STORE) Property Owner: T-C FORUM AT CARLSBAD LLC 4675 MACARTHUR CT, # 110 NEWPORT BEACH, CA 92660 FEE ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL STRONG MOTION-COMMERCIAL BUILDING PERMIT FEE ($2000+) MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE BUILDING PLAN CHECK FEE (BLDG) Total Fees: $1,156.61 Total Payments To Date: $1,156.61 Applied: 10/08/2020 Issued: 07/29/2021 Finaled Close Out: 01/11/2022 Inspector: Final Inspection: Contractor: KIRKLEY CORPORATION INC PO BOX 7268 REDLANDS, CA 92374-0000 (909) 792-4625 Balance Due: PB urn 11/04/2021 AMOUNT $60.00 $26.05 $600.92 $45.00 $4.00 $420.64 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov (_ City of Carlsbad Job Address 1923 Calle Barcelona COMMERCIAL BUILDING PERMIT APPLICATION B-2 Plan C hl•Ck O:ClQZQ-CA( lst Value 93,C)2u PC OPfH"it -------- Date _,_\.....,O._-_<o--=--_-..:...c_l= __ _ Suite: 149 APN: 255-012-04-00 ------ Tenant Name: Jimbo's Naturally CT/Project#:. _________ lot u: ___ _ Occupancy: Grocery store (M) Construction Type: VN fire Sprinklers:®' no Air Conditioning: <S.!Y no hfW r c,t.5< RIPTloN of WORt<. Replace existing lighting and provide new interior design decor at Retail Area 0 Addition/New: __________ New SF and Use, __________ New SF and Use, ___ Deck SF, Patio Cover SF (not including flatwork) [ZI Tenant Improvement: 2,000 SF, _____ SF, Existing Use Grocery Store Proposed Use Grocery Store Existing Use ______ Proposed Use _____ _ LJ Pool/Spa: ____ SF Additional Gas or Electrical Features? ___________ _ D Solar: ___ KW, __ Modules, ___ Mounted, Tilt: Yes/ No, RMA: Yes/ No, Panel Upgrade: Yes/ No D Plumbing/Mechanical/Electrical only: Existing Mech. No Change / Plumbing & Electrical Revised CJ Other: ------------------------------------ APPLICANT (PRIMARY) PROP£RTY OWNER Name: Anthony Mansour Name: T-C FORUM AT CARLSBAD, LLC Address: i:)t..\,Ct<::/ tJt;a~.q; {)/ ,ti,\ OD Address: 730 Third Ave, MS 730/12/02 City: ~9-~s' ~ctC5tate:CA:: Zfp:9:hlt\J I City: New York State: NY Zip: 10017 Phone~~~-Sdi.:-\S~ct Phone: _________________ _ Email: -\. tr).Ql.0,,$6 ut::: §2 O\a..nf> oc,,rascb,:wJ.Js~ail: __________________ _ Ul516N PROFl:SSIONAI Name: Anthony Mansour Address: 6498 Weathers Place Suite 100 City: San Diego State: CA Zip: 92121 Phone:(858} 558-1509 Email: tmansour@mansourarchitecture.com Architect State License: C20392 ---------------------- CONTRACTOR BUSINESS Name: K, ( \.5., \ e t) C:, o c, fo,~-..,.\.: ,) :::,.. Address: f . (2 (?) ox: J .1. h 9 City: (<,, 1$,,)ur~l,c State: C,..':\; Zip: ~ ,i_3 75 Phone: =\ Q '\ -J G.,4'. ~ Y (::2 a,.5 Email: , !:>f~ k ,r \( \e ~ C o 7 f • (,.o C'\ State License: '-iWc. (:, Bus. license: @Soo 7fSl-[;6-~ (Sec. 7031.5 Business and Professions Code: Any City or County whk h requires a permit to construct, alter, Improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she Is lfcensed pursuant to the provisions of the Contractor's License law (Chapter 9, commending with Section 7000 of DMslon 3 of the Business and Professions Code) or that he/she Is exempt thererrom, and the basis for the a11e1ed exemption. Any vlol.atlon of Section 7031.S by any applicant for a permit subjects the applicant to a civil µ.nalty of not more than five hundred dollan (SSOO)). 1635 Faraday Ave Carlsbad, CA 92008 B-2 Ph: 760-602-2719 Fax: 760-602-8558 Page 1 of 2 Email: Bu1Jd1ng@carlsbadca.gov Rev. 06/18 I hearby affirm under penalty of perjury Q!1£ of the following declaratJons: '.:JI have and WW maintain ;i cN!ifu;ate of con5ent to self-insure fo1 workers· compe11sn!ion pioviticd by $t>ction 3700 of tile tab-or Code, for the performance of the wo1k which this permit is issued (ill have and will maintain worker's compensation, as requiled by Se-ction 3700 of the labor Code, perforniance of \he work for which thh permit 1s 'My workers' comp_ensation if!?mtnce cardet and policy number are: lhsurance Company N;uue: -"'"-""'""~~-"-'>CL,J:.-""'""""'"'"*~~:1-,4, ·•'--·''""·-"'··'',;; + Policy No . ..lt,J..;...~.~? S_1..;:.:_:;i,,11iratlo11 Date: "'1. · .cl...'->..t,.LJ._.C,:,e..! CJ CertifJcate of Exemption: I certify that in tlw performance of the work for which this per,mt 1~ lssued, ! shat! not employ any person i11 anv manner so as to be come subjert to the workers' cornpemafa,r, t.1ws of California. WARNING: failure to secme workers compellsat100 coverage is unlawful, and shall subject <111 emplover to crhnhlill penalties lltld civil fines up to $100,000.00, In addition the to the cost of rompematlon, damage~ as provided for In SPction 3'106 of th!'! tahor code, lntNesl and attorney's fees. CONTRACTOR SIGNATURE: DAlE: P'. /; ·•!< I hereby affirm that I am f'Xempt from Contractor's License I.aw for the following rea!Jon: 0 I, as owoN of the property or mv e111ploy€e~ with wages as tlleir so!e .:ompensalioo, will Uo the work nnd the strw.:ture ls not ·intended or offered for sale (Sec 7044, Bustoe)s and Professions Code: The Contractor's license tawdoes not apply to an owner of property who builds or improves thereon, and who dmn such work himseH or through his own emp!ovees, provided that such itnprovemeots are net mtended or offered for sale, rf, however, the building or improvement is sold within one year of completion, the owner•bui!de1 wm have the burden of proving that he did not build or improve for the purpoHi of silte). CJ I, as owne, of the p1 operty, am exdt1sively contractrng with llcettsed cctt1tn.cto1 s to construct tile prnject (Sec. 7044, Business a11d Profess.iom Code: The Contractor's Ucense law dof's not appfy to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's Lh:enrn liiW). O I ant e,xempt under Sec.Hon ________ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. !'J Yes O No 2, I {have/ have not} signed an application for a bultding permit for the proposed work 3. I have contracted with !he following per:rnn (firm) to provide the prop¢sed construction (Include name address I phone I contractots' license number); 4. I plan to provide portions of the work, but/ have hired the following person to c.oordinate, mpervise and provide the major work {mclude name/ address/ phone/ .:ontractors' flcense number): 5. 1 wiH provide some of the work. bot I have wn:tracted (hired) the following persons to provide the work mdicated (include name I address I phone/ type of work.); OWNER SIGNATURE: DATE: _____ _ Iii I hereby affirm that there ls a construction lending agency for the performance of the work this permit Js: iS:SIJ.f'd (Sec. 3097 W CMI Code). Lender's Name; Lender's Address: ____________ _ ff!iN iUR NO/\! ,11 81111 ls. the applicallt or future building occupant required to submit a business pfan, acutely hazardous materials: registration form or risk management and prevelltion program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes !ti No Is the applJc.ant or future building on::upan! required to obtain a perrnit from the air pollution co11tro! district or air quafhy management district? C) Yes rt;t No Is the facility to be constructed wlthln 1,000 feet of the outer boundary of a school site? CJ Ye5 .<") No IF ANY OF THE ANSWERS A Rf YES, A FIN Al CERTIFICATE OF OCCUPANCY MA 'I' NOT 8£ ISSUEO UNLESS THE APPLICANT HAS MET OR ts MEETING TH! REQUIREMENTS Of THE OFr-lCE or EMERGENCY S£RVICES ANO THE AIR POLLUTION CONTROL DISTAjCT, J certify that/ have read the apµhcatioo and state that thr above information is correct al"ld that the information on the j)lam Js accurate. I agree to comply witft .)I/ City ordinances and Stiite laws relating to building construction I hereby authonze representative of the City of carkbad to enter uJ)Orl the above me11tioned property for lnspectlOo pu<po!les. I Al.SO AGREE TO SAVE, IN0£MN/FY AND l(Efp HARMLESS THE CITY Of CARtSBAO AGAINST Alt UASIUTIES, JUDGMENTS, COSTS ANO EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUFNCE Of TiiE GRANTING OF THIS PfRMIT.OSHA:AnOSHA permll ls required forexcavatfom over 5'0' deep and demolition Of construction of structure5 over 3 stories in llCf£/1t fXPIRA TION: fve1y permit 1%tted by the 8trilding Off!claf under the provislons of this Code ~all expire by IJrnitatlon and become nufl and void if the building or work authorized by swh pennit is nof commencedwlthin 180 days from !he date of such permit or if thf' building or work authorized by such permit is suspended or abandorwd at any time after the work Is commenC'E'<l for a periodo! l,BC;llays (Section 106 4 4 Uniform Buttdwig Code) ,-1""' " , -r' /S ,j ;,/✓ ,' APPLICANT SIGNATURE: , /~'h,, /i 1,/ , C.~/·'('. 1635 Faraday Ave Carlsbad, CA 92008 B-2 0 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of 2 Email: Rev. 06118 Building Permit Inspection History Finaled (city of Carlsbad PERMIT INSPECTION HISTORY for (CBC2020-0407) Permit Type: BLDG-Commercial Application Date: 10/08/2020 Owner: T-C FORUM AT CARLSBAD LLC Work Class: Tenant Improvement Issue Date: 07/29/2021 Subdivision: CARLSBAD TCT#92-08 GREEN VALLEY Status: Closed -Finaled Expiration Date: 04/11/2022 Address: 1923 CALLE BARCELONA, # 149 IVR Number: 29240 CARLSBAD, CA 92009-8458 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 09/14/2021 09/14/2021 BLDG-SW-Pre..Con 166426-2021 Passed Paul Burnette Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 09/21/2021 09/21/2021 BL0G-84 Rough 166827-2021 Partial Pass Tim Kersch Re inspection Incomplete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 09/22/2021 09/22/2021 BLDG-17 Interior 167018-2021 Passed Paul Burnette Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 10/13/2021 10/13/2021 BLDG-23 GasfTestJRepairs 168402-2021 Passed Tim Kersch Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 11/04/2021 11/04/2021 BLDG-Final Inspection 170065-2021 Passed Tim Kersch Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes Tuesday,January11,2022 Page 1 of 1 DATE: 11/24/2020 JURISDICTION: Carlsbad PLAN CHECK#.: CBC 2020-0407 ✓• EsG1I SETH PROJECT ADDRESS: 1923 Calle Barcelona PROJECT NAME: TI Jimbo's o/4PPLICANT ! JURIS. ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: Anthony Mansour ~ EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: 858-558-1509 Date contacted,l\2rf20 (byW'l) Email: tmansour@mansourarchitecture.com Mail Telephone 0 REMARKS: By: Steven Miller EsGil Fax In Person Enclosures: 11/24 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 DATE: 10/22/2020 JURISDICTION: Carlsbad PLAN CHECK#.: CBC 2020-0407 ✓• EsG1I SETI PROJECT ADDRESS: 1923 Calle Barcelona PROJECT NAME: TI Jimbo's □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Anthony Mansour D EsGil staff did not advise the applicant that the plan check has been completed. ~ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: 858-558-1509 Date contacted: Mail Telephone 0 REMARKS: By: Steven Miller EsGil (by: ) Email: tmansour@mansourarchitecture.com Fax In Person Enclosures: 10/22 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBC 2020-0407 10/22/2020 PLAN REVIEW CORRECTION LIST COMMERCIAL PLAN CHECK#.: CBC 2020-0407 OCCUPANCY: TYPE OF CONSTRUCTION: ALLOWABLE FLOOR AREA: SPRINKLERS?: REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 10/8/2020 DATE INITIAL PLAN REVIEW COMPLETED: 10/22/2020 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad USE: ACTUAL AREA: STORIES: HEIGHT: OCCUPANT LOAD: DATE PLANS RECEIVED BY ESGIL CORPORATION: 10/12/2020 PLAN REVIEWER: Steven Miller This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2019 CBC, which adopts the 2018 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2018 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBC 2020-0407 10/22/2020 NOTICE: CITY AND ESGIL'S HOURS OF OPERATION ARE AFFECTED BY THE CURRENT COVID-19 EPIDEMIC. PLAN REVIEWER MAY NOT BE AVAILABLE TO ANSWER QUESTIONS BY PHONE, BUT MAY BE REACHED BY E-MAIL AT stmiller@esgil.com . (858) 225-2775 GENERAL Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 1. Plans may be submitted in electronic format, subject to the jurisdiction's approval. If so, they must have restrictions removed from the security settings. Electronic plans with restrictions to markups, printing, or stamping will not be approved. 2. A reminder that due to Covid-19, the City will not permit counter corrections. Please make sure all the items are satisfied; otherwise, another round of corrections will be necessary. PLANS 3. Provide the names, addresses and telephone numbers of the owner and the responsible design professionals on the Title Sheet. Sec. 107.2. 4. All sheets of the plans and the first sheet of the calculations are required to be signed by the licensed architect, engineer, or person responsible for the plan preparation. California State Law. 5. For any tenant improvement that requires a grease interceptor, the City of Carlsbad requires that a grease interceptor be shown on the plans. 6. Page T1 please update the governing codes to the current adopted codes Carlsbad CBC 2020-0407 10/22/2020 7. Provide a statement on the Title Sheet of the plans, stating that this project shall comply with the 2019 California Building Code, which adopts the 2018 IBC, 2018 UMC, 2018 UPC and the 2017 NEC. 8. Provide the Carlsbad Climate Action Plan form B55 to the title page T1. 9. Provide a completed Carlsbad Climate Action Plan form B50. 10. Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: • Occupancy Classification(s) • For Mixed Occupancy Buildings, state whether the "nonseparated" or "separated" option was chosen from Sections 508.3/508.4. • Description of Use • Type of Construction • Sprinklers: Yes or No • Stories ♦ Height • Floor Area • Occupant Load State the occupant load on the title sheet. 11. Provide a note on the plans indicating if any hazardous materials will be stored and/or used within the building which exceed the quantities listed in IBC Tables 307.1(1) and 307.1(2). 12. On the cover sheet of the plans, specify any items that will have a deferred submittal (trusses, fire sprinklers/alarms, etc.). Additionally, provide the following note on the plans, per Sec. 107.3.4.1: "Submittal documents for deferred submittal items shall be submitted to the registered design professional in responsible charge, who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and that they have been found to be in general conformance with the design of the building. The deferred submittal items shall NOT be installed until their design and submittal documents have been approved by the building official." MISCELLANEOUS LIFE/SAFETY 13. Please provide notes on the plans to show the suspended ceilings in Seismic Design Categories D, E & F comply with ASCE 7-16 Section 13.5.6.2.2 as follows: a. The width of the perimeter supporting closure angle or channel shall be not less than 2.0 in. unless qualified perimeter supporting clips are used. Carlsbad CBC 2020-0407 10/22/2020 b. Closure angles or channels shall be screwed or otherwise positively attached to wall studs or other supporting structures. Perimeter supporting clips shall be qualified in accordance with approved test criteria per Section 13.2.5. c. Perimeter supporting clips shall be attached to supporting closure angle or channel with a minimum of two screws per clip and shall be installed around the entire ceiling perimeter. d. In each orthogonal horizontal direction, one end of the ceiling grid shall be attached to the closure angle, channel, or perimeter supporting clip. The other end of the ceiling gird in each horizontal direction shall have a minimum 0.75-in clearance from the wall and shall rest upon and be free to slide on a closure angle, channel, or perimeter supporting clip. e. Ceiling areas over 2500 ft.2 must have seismic separation joints or full height partitions. f. Ceilings without rigid bracing must have 2" oversize trim rings for sprinklers and other ceiling penetrations. STRUCTURAL 14. Page A4 detail 24 refers to structural dwgs 1 and 5 on page S.3 please provide or state actual location of details on the structural drawings. DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT TITLE 24 The following disabled access items are taken from the 2016 edition of California Building Code, Title 24. Per Section 1.9.1, all publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities. COUNTERS AND TABLES 15. The tops of tables and counters shall be 34" maximum above the floor. Section 11 B-904. Where a single counter contains more than one transaction station, such as a bank counter with multiple teller window or a retail sales counter with multiple cash register stations, at least one of each type of station shall be located at a section of counter that is at least 36" long and no more than 28" to 34" high. Section 11 B-go4_ Page A 1 the new outside seating area you need to show a minimum of 5% of the seating area as accessible. And show the clear floor space needed for the seating area. ADDITIONAL 16. To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Carlsbad CBC 2020-0407 10/22/2020 17. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: □ Yes □ No 18. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Steven Miller at Esgil. Thank you. Carlsbad CBC 2020-0407 10/22/2020 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Steven Miller PLAN CHECK#.: CBC 2020-0407 DATE: 10/22/2020 BUILDING ADDRESS: 1923 Calle Barcelona BUILDING OCCUPANCY: M BUILDING AREA Valuation PORTION ( Sq. Fl.) Multiplier TIM 2000 46_51 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code CB By Ordinance 1997 UBC Building Permit: Fee ~ ... I <J .-. !997 UBC Plan Check Fee ~ Type of Review: Complete Review Reg. VALUE Mod. r Structural Only r Repetitive Fee -~ Repeats r Other r Hourly EaGil F- ~ e----------------<l Hr @ * Comments: ($) 93,020 93,020 Sheet 1 of 1 Gss•m1yamoto. Calculations for 20095A Jimbos Phase 2 1923 Calle Barcelona# 149 Carlsbad, CA 92009 Mansour Architecture 6498 Weathers Place, Suite 100 San Diego, CA 92121 Phone: 858-558-1509 Fax: 858-558-9221 > 1--0 00 lh..._ ON ■-­"-1"0 Q ON~ N-cx::> ~-o 00 l.() ~ I ~ 0 N 0 N 0 aJ 0 8/25/2020 U.S. Seismic Design Maps OSHPD Jimbos Carlsbad Phase 2 1923 Calle Barcelona, Carlsbad, CA 92009, USA Latitude, Longitude: 33.0706258, -117 .2666012 \ \ \ \ \ \ I I I I I I I I I I I I I I I I I I , Google Date Design Code Reference Document Risk Category Site Class I Type Value Ss 1.057 S1 0.381 SMs 1.268 I SM1 null -See Section 11.4.8 Sos 0.845 So1 null -See Section 11.4.8 Type Value soc null -See Section 11.4.8 Fa 1.2 Fv null -See Section 11.4.8 PGA 0.467 FPGA 1.2 PG~ 0.56 TL 8 SsRT 1.057 SsUH 1.187 SsD 1.5 S1RT 0.381 S1 UH 0.421 S10 0.6 PGAd 0.553 CRs 0.891 https:1/seismicmaps.org Casa De Bandini ' Bed Bath & Be! ' I I I I f .t-:1 pple Carlsbad f The F~rum Carlsbad I I I I Walmart Supercenter f ~El 9.,, I \ 8/25/2020, 1:47:35 PM ASCE7-16 II ,--' I I I ' I , D -Default (See Section 11.4.3) Description Description MCER ground motion. (for 0.2 second period) MCER ground motion. (for 1.0s period) Site-modified spectral acceleration value Site-modified spectral acceleration value Numeric seismic design value at 0.2 second SA Numeric seismic design value at 1.0 second SA Seismic design category Site amplification factor at 0.2 second Site amplification factor at 1.0 second MCEG peak ground acceleration Site amplification factor at PGA Site modified peak ground acceleration Long-period transition period in seconds Probabilistic risk-targeted ground motion. (0.2 second) Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration Factored deterministic acceleration value. (0.2 second) Probabilistic risk-targeted ground motion. (1 .0 second) Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration. Factored deterministic acceleration value. (1.0 second) Factored deterministic acceleration value. (Peak Ground Acceleration) Mapped value of the risk coefficient at short periods . \ I I I I \ I I I I I I I I I I I I I I I I I I I I I I I I \ Map data ©2020 _j 1/3 SHEET ____ _ PROJECT H~ (/W I/ 13.A0 NO. ___ _ Gss•m1yamoto. ENGR ---'(;()~~---__;__ DATE _____ _ :) DINING 102 I Pl..~ '?);I~ W;oi ~ ~ ., '1 P">f c; I 'I.:' b1(' 2. ,,.., P'>t"" W -; 4-Cl-~i)~ <P rt.f --w ~,:.. "31... 1IF f;;if 11-: 1Dlif -;;.. \ ll l'- -1:---, I ,z... ,f' ~ l,(~ (~01-'=t \(rt·~:; r'\Av..-~ t;. ~ ''"'" 1:x., t). i;,s I N4- 6 . c.,(tA-'1 l t'\eCf::: kY>t?'Ll-OA:? 1"C RS:; ~ * . .ff,f-K~ ~Wf tJJJ~ I ~/ ~~~"" f<>Of ~6. ~ ~ ~ l9r w ~ 1-2.0rVf ~ rtu t,J ~ ~ ~~ WA-t.A- Dl/WA\A,, sit lo1r' i.t i 5l'b '$WJ /,1 M\~ t1.5 'fp(,f SHEET ____ _ \ l ' /IA..., AJ' \~ .,., PROJECT -.J-! . ..:..:..~.c.=.,;;.VL?Vb=---'-=--t..-______ _ NO. ___ _ Gss•m1yamoto. ENGR O'.'.:t-, DATE. ____ _ PL,,;: \i;; ~ lA,, .... / '20~ ~ © 1:> 1Jv¼\"~~ ~I/ ~A~ 11 ,~1 ~V2;11tJ~ (I?) lb 661 @ ~,i ~'-' Jb \ 'I. ., , 1r tv1. tq,\, ,,, \.Ii rs I q-:>o(J\ : 1 t,'6dlf ~/ ~ a. 2J 1ft' l" '.J '2, \G, f 3o' f W• z,;fa.,,1-) • '1<& ,...,. " r-~ 41°~,, (11/'1-t 10) [-;-i/,'l-) ~ i,o /2t,-:: l r;~? ttrz.. ~ 14 7 o"f H-f, \l 2,io'~ <-11h~ollrt ~ (IG~ \+,t;~ , ~ ( W-01-1 L@ ~ CMe'u~ p~ l,9e,,/"!>1,,)-: <p0s;r ~ ,tf \ 0 -..NO 9v'J 6 ~-w I I '"M-~ 4 ~ ( '~'5)=~ 1 'l-o ;v. I-:: t1.J(1..z-0J-;. --;4v'f > ~'5¢ p~ Gss•m1yamoto. 20095A Jimbos Phase 2 Appendix ) 1.1 I 61..511 4ld,: fl UM' LNllt Ollt. ,:. GM6Tl-4't • fl'UGe_ W1'4--16d EAaf &!:OE ~ 5l"JUr', f'l"'P 'TN! Ll>E ~TIN!-AAl»IO ltOOI' oou.JH TYP, SEE AAGl<.S"""'6'<::RSIZ! ;.>c>Loc;,.Tl()H. Existing roof trusses and girders have allowance for hung stud wall below. G()!ffll,AGTO!t !0 """"101: -- l>C --1IE f<Mf'. -~ -· ~illl.. !'itl&Utzll', TO P'lltDYU:IE l>C """"""'--"""' P'Olt..U.MltOOfTO!',l«)-=-r. T J. MGlll~T TO l'l'OYIC>I: l!ll.',GIN6 • MSOA'I~ JU. T'ltL.e!,e H.eT' ef: \ft.ll'E) fllOI'. THE l!GW'. LOADS -ISCIIP. M!l'1l Oil MeGH. l!N&IM!l!lt M.15T IM'OIIM THE 1111156 GOW-1, T!ll.l!l!l!S NIU. l!E -Tl! ,oit ~GIJf'.-Ol<ltOOf--TODe~. 10 Hazardous Materials Questionnaire County of San Diego, Department of Environmental Health and Quality PO Box 129261, San Diego, CA 92112-9261 (858) 505-6700 (800) 253-9933 www.sdcdehq.org Record ID#: Not in System Plan Check#: DEH2021-HHMBP- 009764 Business Name Business Contact Telephone# Plan File# Jimbo's Naturally T-C Forum at Carlsbad, LLC 8585581509 Project Address City Zip Code APN # 1923 Calle Barcelona Carlsbad I State CA 92009 255-012-04-00 Applicant Applicant E-Mail Applicant Telephone # brent v reeder bvreeder@cox.net 8585581509 The following questions represent the facility's activities, NOT the specific project description. PART I FIRE DEPARTMENT-HAZARDOUS METER\ALS DIYISION· OCCUPANCY CLASSIFICATION:{Not required for projects within the City of San Diego.) Indicate by selecting the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are selected, Applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: Mercantile Facility's Square Footage (including proposed project): 18088 □ Explosive or Blasting Agents □ Organic Peroxides □ Water Reactives □ Corrosives □ Compressed Gases □ Oxidizers □ Cryogenics □ Other Health Hazards □ Flammable/Combustible Liquids □ Pyrophorics □ Highly Toxic or Toxic Materials □ None of These □ Flammable Solids □ Unstable Reactives □ Radioactives PART U· SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION (HMD):lf the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, in person at 5500 Overland Ave., Suite 110, San Diego, CA 92123, or by phone at(858) 505-6700 prior to issuance of a building permit. FEES ARE REQUIRED. Project Completion Date: 3/31/2021 1. 2. 3. 4. 5. 6. 7. 8. YES NO □ '" Is your business listed on the reverse side of this form? (check all that apply). □ '" Will your business dispose of Hazardous Substances or Medical Waste in any amount? "' □ □ "' □ □ 0 Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds, or 200 cubic feet? '" "' □ "' Will your business handle carcinogens or reproductive toxins in any quantity? Will your business use an existing, or install an underground storage tank? Will your business store or handle Regulated Substances (Ca\ARP)? Will your business use or install a Hazardous Waste Tank System {Title 22, Article 10)? ~ Will your business store petroleum in tanks or containers at your facility with a total storage capacity equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act). □ □ □ CalARP Exempt CalARP Required CalARP Complete Review Date: PART Ill· SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT fAPCD): If the answer to Question #1 is 'Yes' and the answer to Question #2 is 'No', the applicant must contact the APCD prior to the issuance of a building or demolition permit. If any answer to Questions #3, #4, or #5 is 'Yes', the applicant must contact the APCD prior to the issuance of a building or demolition permit. If the answer to Question #3 or #4 is 'Yes', the applicant may need to submit an asbestos notification form to the APCD at least 10 working days prior to commencing demolition or renovation (some residential projects may be exempt from the notification requirements). Contact the APCD at 10124 Old Grove Road, San Diego, CA 92131 or telephone (858) 586-2600 for more information. 1. 2. 3. 4. YES NO □ ., □ □ □ □ □ ., Will any existing building materials be disturbed as part of this project? (If the answer is 'Yes', an asbestos survey may be required.) Has a survey been pertormed to determine the presence of asbestos containing materials? Will the project involve handling or disturbance of any asbestos containing materials? Will the project involve the removal of any load supporting structural member? 5. 6. □ □ Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD factsheet at http://www.sdapcd.org/infolfacts/permits.pdf □ (ANSWER ONLY IF QUESTION 5 IS 'YES') Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? Search the California School Directory at http://www.cde.ca.gov/re/sd/ for public and private schools or contact the appropriate school district. Briefly describe business activities: Briefly describe proposed project Grocery Store Replace existing lighting and provide inter design decor. Swap out equipment. I declare under penalty of perjury that to the best of my knowledge and belief, the responses made herein are true and correct. Iii; Fees Acknowledged: !&I brent reeder 3/3/2021 Name of Owner or Authorized Agent Date FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: BY· EXEMPT OR NO FURTHER INFORMATION REQUIRED Q 7/26/2021 FOR OFFICIAL USE ONLY DATE: ___________ _ RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY G. Garcia '",IGtlf.TLt/0: 7/26/2021 APCD RELEASED FOR OCCUPANCY COUNTY-HMO APCD *A stamp in this box .!ID.!Y. exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply. DEHQ_HMD HMBP Questionnaire v 1.34 (212021) Printed on: 7726/2021@ 11:42 AM Date: 9/18/20 ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com Business Name: Jimbo's Naturally street Address: 1923 Calle Barcelona Ste. 149, Carlsbad, CA 92009 Email Address: tmansour@mansourarchitecture.com PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) C8:] Check all below that are present at your facility: o Acid Cleaning o Assembly o Automotive Repair o Battery Manufacturing o Biofuel Manufacturing o Biotech Laboratory o Bulk Chemical Storage o Car Wash o Chemical Manufacturing o Chemical Purification o Dental Offices ■ Dental Schools ■ Dental Clinics o Dry Cleaning o Electrical Component Manufacturing o Fertilizer Manufacturing o Film/X-ray Processing o Food Processing o Glass Manufacturing o Industrial Laundry o Ink Manufacturing o Laboratory o Machining/Milling o Membrane manufacturing (i.e. water filter membranes) o Metal Casting/Forming o Metal Fabrication o Metal Finishing • Electroplating ■ Electroless Plating • Anodizing ■ Coating (i.e. phosphating) • Chemical Etching/Milling ■ Printed Circuit Board Manufacturing o Metal Powders Forming o Nutritional Supplement/Vitamin Manufacturing o Painting/Finishing o Paint Manufacturing o Personal Care Products Manufacturing o Pesticide Manufacturing/ Packaging o Pharmaceutical Manufacturing (including precursors) o Porcelain Enameling o Power Generation o Print Shop o Research and Development o Rubber Manufacturing o Semiconductor Manufacturing o Soap/Detergent Manufacturing o Waste Treatment/Storage New Business? Yes D No jE SIC Code(s) if known: _____ _ Date operation began/will begin:~2~O~O~3~---- Tenant Improvement? Yes IXI NoD If yes, briefly describe improvement: Replace Existing Lighting at Retail Area and Provide New Interior Design Decor at Retail Area Description of operations generating wastewater (discharged to sewer, hauled or evaporated):,_E_X_E_M_P_T ______ _ Estimated volume of industrial wastewater to be discharged (gal/ day): _E_X_E_M_P_T ______________ _ List hazardous wastes generated (type/volume): __________ E_X_E_M_P_T ______________ _ Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? Yes D Date: EXEMPT No D Page 1 of 2 ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com The commercial enterprises listed below are a partial listing of businesses that are exempt from industrial wastewater discharge permitting under normal operating conditions. They are exempt because (a) they discharge no process wastewater (i.e., they only discharge sanitary wastewater with no pollutants exceeding any local limits), and (b) they have no potential to negatively impact the EWPCF or other wastewater treatment plants in the ESS. Any questions regarding exemptions should be referred to EWA Source Control staff. o Automobile Detailers o Hotels/Motels (no laundry) o Barber/Beauty Shops o Laundromats o Business/Sales Offices o Libraries o Cleaning Services o Medical Offices (no x-ray developing) o Carpet/Upholstery o Mortuaries o Childcare Facilities o Museums o Churches o Nail Salons o Community Centers o Nursing Homes o Consulting Services o Office Buildings (no process flow) o Contractors o Optical Services o Counseling Services o Pest Control Services (no pesticide repackaging for sale) o Educational Services (no auto repair/film developing) o Pet Boarding/Grooming Facilities o Financial Institutions/Services o Fitness Centers o Gas Stations (no car wash/auto repair) J • Grocery Stores (no film developing) I o Residential oasea Businesses CERTIFICATION STATEMENT o Postal Services (no car wash/auto repair) o Public Storage Facilities o Restaurants/Bars o Retail/Wholesale Stores (no auto repair/film developing) o Theaters (Movie/Live) I certify that the information above is true and correct to the best of my knowledge. Signature: _____________ _ Print Name: ___________ _ DATE: _____ _ Facility Contact: Anthony Mansour Title: Architect ENCINA WASTEWATER AUTHORITY 6200 AVENIDA ENCINAS, CARLSBAD, CA Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com Page 2 of 2 ' ( City of Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of permits are not required to fill out this form ❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool ..i If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. ..i Details on CAP ordinance requirements are available on the city's website . ..i A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and download the latest form. Project Name/Building Permit No.: Property Address/APN: 1q2-o C0--1\t fur co lCYQQ\ Applicant Name/Co.: Applicant Address: Contact Phone: Contact Email: BP No.: Contact information of person completing this checklist (if different than above): Name: Company name/address: Contact Phone: Contact Email: CtQ.roro-0407 Applicant Signature: _______________ _ Date: ________ _ B-50 Page 1 of 6 Revised 08/19 CITY OF CARLSBAD POLICIES AND PROCEDURE i,,=.~=======-~==~=r--~=--=--=====~========= NUMBER: 80-6 EFFECTIVE: 5/1/92 SUPERSEDES: 80-6(9/10/80) 80-6( 5/01 /81 ) SUBJECT: ROOF MOUNTED EQUIPMENT SECTION: BUILDING DEPARTMENT PURPOSE: PROVIDE INSTALLATION STANDARDS FOR ALL ROOF MOUNTED EQUIPMENT AND PENETRATIONS ON COMMERCIAL AND INDUSTRIAL BUILDINGS. INTENT: POLICY: A. B. C. 1. 2. 3. 4. 5. 6. 7. Maintain roof integrity. Prevent hazardous condition to firemen who must fight fire on the roof. Provide an installation that is aesthetically sensitive to the building and the adjoining properties. All equipment shall be concealed from view and the design* shall meet the approval of the Planning Department. All equipment shall be specifically designed and approved for exterior use and shall be approved by the City of Carlsbad Building Department. All roof mounted equipment shall be on a platform which shall be an integral part of the roof--flashed and waterproofed. When a screen is approved, it shall have as few roof connections as possible and be structurally adequate. All electrical, plumbing, mechanical duct work and related piping shall be inside the building and not on the roof. All connections related to equipment shall be made in the same roof opening on the platform or have the prior approval from the building official. Sewer vents shall be brought to one main vent below the roof and have one penetration where restrooms or other plumbing fixtures are back to back or in the general proximity. Air exhaust fans and other equipment shall be within the building and use the same roof opening where restrooms and other equipment are back to back or in general proximity. Existing buildings and equipment, remodel or replacement, shall meet the above regulations or shall have the prior approval from the building official. Where new equipment is installed. unused or abandoned equipment, including all roof mounted piping, electrical, mechanical, duct, and other related appurtenances shall be removed from roof and unused openings properly sealed to maintain roof integrity. *The architect should, through design, conceal the heating/AC unit and other equipment whether they are on the roof or elsewhere. Initiated By: Approved By: SCREENING OF EQUIPMENT Exterior components of plumbing, processing, heating, cooling, and ventilation systems (including but not limited to piping, tanks, stacks, collectors, heating, cooling, and ventilating equipment fans, blowers, ductwork, vents, louver, meters, compressors, motors, incinerators, ovens, etc ... ) shall not be directly visible from a height of five feet from the closest building wall on any lol Scaled elevations of all such equipment, as well as screening materials, are required on all site plans. See example below. PROPERTY LINE 3S LANDSCAPE : SETBACK I I I i ' EXAMPLE OF SCREENING MATERIAL DISPLAY -----~Mr! 6 -------------, 61 _______ ,,. .. pvvstil\lWShl,V ~PSli?S&SlstVYSZ~------------------- PROPERTY LINE 50' LANDSCAPE\ SETBACK >