HomeMy WebLinkAbout2511 GATEWAY RD; ; CBC2021-0233; PermitPERMIT REPORT Commercial Permit Print Date: 01/10/2022 Job Address: 2511 GATEWAY RD, CARLSBAD, CA 92009-1742 Permit Type: Parcel#: Valuation: BLDG-Commercial 2132601100 $28,371.10 Occupancy Group: B, Fl #of Dwelling Units: Work Class: Track#: Lot#: Project#: Plan#: Tenant Improvement Bedrooms: Bathrooms: Construction Type: IIV Orig. Plan Check#: Plan Check#: Project Title: Description: VIASAT: Tl OFFICE TO OFFICE/COMPUTER LAB (610 SF) Applicant: SMITH CONSULTING ARCHITECTS DANA TSUI Property Owner: LEVINE INVESTMENTS LP ANDREW COHN 13280 EVENING CREEK DRS, # SUITE 125 SAN DIEGO, CA 92128 2801 E CAMELBACK RD, # 450 PHOENIX, AZ 85016 (858) 793-4777 FEE STRONG MOTION-COMMERCIAL (SMIP) BUILDING PERMIT FEE ($2000+) (602) 248-8181 SB1473-GREEN BUILDING STATE STANDARDS FEE ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL BUILDING PLAN CHECK FEE (BLDG) Total Fees: $559.66 Total Payments To Date: $559.66 (city of Carlsbad Permit No: CBC2021-0233 Status: Closed -Finaled Applied: 06/29/2021 Issued: 08/10/2021 Finaled Close Out: 01/10/2022 Inspector: Final Inspection: Balance Due: TKers 12/28/2021 AMOUNT $7.94 $271.60 $2.00 $43.00 $45.00 $190.12 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov ( Cicyof Carlsbad COMMERCIAL BUILDING PERMIT APPLICATION B-2 Plan Check CPiC-')QU-())~ Est. Value .2g, 37 J. {0 PC Deposit/ Date {a /;).,'j _:;./ I , Job Address 2511 Gateway Drive Sulte: _____ ,APN: 213-260-01 Lot#: Tenant Name:_v_iasa1 ______________ _ Year Built:.20_,_• ___ Occupancy:,_• ___ _ 111B 00 00 Construction Type'-'' c:.:...·;;;;... ___ Flre Sprinklers: yes no 'A/C: yes no BRIEF DESCRIPTION OF WORK: Renovation of 61 O sf including associated mechanical and electrical work. D Addltlon/New:. __________ New SF and Use, __________ New SF and Use, ___ Deck SF, Patio Cover SF (not including flatwork) [!] Tenant lmprovement:_61_0 ____ SF, Existing Use,_•_ffl_ce _____ Proposed Use office/ computer lab _____ SF, Existing Use Proposed Use ______ _ D Pool/Spa:, _____ .SF Additional Gas or Electrical Features? ___________ _ no □□ □□ D Solar: ___ ,KW, ___ ,Modules, ___ Mounted, Tilt: Ves / No, RMA: Yes/ No, Panel Upgrade: Yes/ No D Plumblng/Mechanlcal/Electrlcal Only: ________________________ _ D Other: This permit Is to be Issued In the name of the Property owner as owner-Builder, licensed contractor or Authorized Agent of the owner or contractor. The person listed as the Applicant below will be the main point of contact throughout the permit process. PROPERTY OWNER APPLICANT Ii PROPERTY OWNERS AUTHORIZED AGENT APPLICANT 0 Name:,_"""' _________________ ,Name: o.,ar~ssc,--.. Address: 2511 Gateway Drive Address: 132ao Evening Creek or Ste 125 City: Carlsbad Phone: 75o-s83-4006 State:,_c_A_ ... Zlp: e2122 City: caasbad State: CA Zlp:,..:•.:.21.:.20;..._ __ Phone: 858-783·4777 Email: Jeremy.thompson@viasa1.com DESIGN PROFESSIONAL Name: Dana Tsui-SCA Architecture APPLICANT Ii Email: Jeremy.thompson@viasat.com CONTRACTOR NT 0 Name: __ --,,!~-c.;;:.:::........,....4'"-!1'-:L,,;.a::~➔=+:==-....- Address: 13290 Evening Creek Dr Ste 125 Addres City: San Diego State:._c_A __ .Zip: 92128 Clty:,_.,L.C.----,---~:State .z1p: __ .,:;.;.J....::::;=:;;..~ Phone: 858•73-4777 Phone: a~ 2 -~1(:7 --?b I Email: danat@sca-sd.com Email: Architect State License: _c_11_70_1 _______ State Ll-.c-e-ns_e_: Z....,....&"'4-....,,../......,b_h,,.."'5....,..-.-L-lc-en-s-e:_A...,...~---=--t)..,,..=3"4) -~-, -UJ/6 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-2 Page 1 of2 Rev. 08/20 IDENTIFY WHO WILL PERFORM THE WORK BY COMPLETING (OPTION A) OR (OPTION B) BELOW: (OPTION A): LICENSED CONTRACTOR DECLARATION: I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. I also affirm under penalty of perjury one of the following declarations: ■ I have and wlll maintain a certificate of consent to self•insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is Issued. Policy No. ________________________ _ D Certificate of Exemption: I certify that In the performance of the work for which this permit Is Issued, I shatl not employ any person in any manner so as to become subject to the workers' compensation Laws of California. WARNING: F■llure to secure workers compens■tlon coverage ls unlawful and shall subject an employer to criminal penalties and dvll fines up to $100,000.00, In addition the to the cost of compensation, damages ■s provided for In Section 3706 of the Labor COde, Interest and attorney's fees. CONSTRUCTION LENDING AGENCY. IF ANY: I hereby affirm that there Is a construction lending agency for the performance of the work this perm~I J,-1-•lse~~"!J Lender's Name: Lender's Addres5F--------::5a!,;~~:::,,,....:::....----;~r--y-/&y CONTRACTOR PRINT: PCG Construction SIGN: 01, as owner o roperty or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and essions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through h1 n employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of complet1 he owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively con ting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owne roperty who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License law). 0 I am exempt under Business and Professions Code Division 3, Chapter , 0 "Owner Builder acknowledgement and verification form" has been filled out, signed and attac D Owners uAuthorized Agent Form" has been filled out, signed and attached to this application giving the ag Proof of Identification attached. By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year r to completion of the improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been construe ·n its entirety by licensed contractors. I understand that a copy of the applicable low, Section 7044 of the Business and Professions Code, is available upon request wh submitted or at the following Web site: http://www.leginfo.ca.gov/cafaw.html. OWNER PRINT: SIGN: ________ DATE: _____ ..;;:.,. APPLICANT CERTIFICATION: SIGNATURE REQUIRED AT THE TIME OF SUBMITTAL By my signature below, I certify that: I am the property owner or State of California Licensed Contractor or authorized to act on the property owner or contractor's behalf. I certify that I hove read the application ond state that the above information is correct and thot the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Corlsbod to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE; INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILmES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An fSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. \ '-- APPLICANT PRINT: _o_a_n_a_T_s_u_i ------SIGN: 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-855 Email: Building@carlsbadca.gov B-2 Page 2 of 2 Rev. 08/20 Building Permit Inspection History Finaled (city of Carlsbad PERMIT INSPECTION HISTORY for (CBC2021-0233) Permit Type: BLDG-Commercial Application Date: 06/29/2021 Owner: LEVINE INVESTMENTS LP Work Class: Tenant Improvement Issue Date: 08/10/2021 Subdivision: Status: Closed -Finaled Expiration Date: 03/01/2022 Address: 2511 GATEWAY RD IVR Number: 34265 CARLSBAD, CA 92009-1742 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 08/11/2021 08/11/2021 BLDG-17 Interior 16397 4-2021 Passed Tim Kersch Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-84 Rough 163975-2021 Passed Tim Kersch Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 09/02/2021 09/02/2021 BLDG-85 T-Bar, Ceiling 165732-2021 Passed Tim Kersch Complete Grids, Overhead Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 12/28/2021 12/28/2021 BLDG-Final Inspection 173446-2021 Passed Chris Renfro Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes Monday, January 10, 2022 Page 1 of 1 • l\\T INiERWEST DATE: 08/05/2021 JURISDICTION: CARLSBAD PLAN CHECK#.: CB-CBC2021-0233 PROJECT ADDRESS: 2511 Gateway Drive PROJECT NAME: Viasat -TI SET II □ APPLICANT □ JURIS. ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. 0 The check list transmitted herewith is for your information. The plans are being held at lnterwest until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: Dana Tsui ~ lnterwest staff did not advise the applicant that the plan check has been completed. D lnterwest staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: 858-793-4777 Date contacted: Mail Telephone 0 REMARKS: By: Steven Miller lnterwest (by: ) Email: danat@sca-sd.com Fax In Person Enclosures: 07/19 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 • lW INTERWEST DATE: 07/19/2021 JURISDICTION: CARLSBAD PLAN CHECK#,: CB-CBC2021-0233 PROJECT ADDRESS: 2511 Gateway Drive PROJECT NAME: Viasat -TI SETI D APPLICANT D JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck, ~ The check list transmitted herewith is for your information. The plans are being held at lnterwest until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person, ~ The applicant's copy of the check list has been sent to: Dana Tsui D lnterwest staff did not advise the applicant that the plan check has been completed. ~ lnterwest staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: 858-793-4777 Date contacted: Mail Telephone 0 REMARKS: By: Steven Miller lnterwest (by: ) Email: danat@sca-sd.com Fax In Person Enclosures: 07/19 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 CARLSBAD CBC2021-0233 07/19/2021 PLAN REVIEW CORRECTION LIST COMMERCIAL PLAN CHECK#.: CB-CBC2021-0233 JURISDICTION: CARLSBAD OCCUPANCY: B,Fl USE: Business TYPE OF CONSTRUCTION: IIB ACTUAL AREA: TI 610 sq ft EXISTING 89,010 sq ft ALLOWABLE FLOOR AREA: 69,000 STORIES: 3 HEIGHT: No Change SPRINKLERS?: Yes REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 06/29/2021 DATE INITIAL PLAN REVIEW COMPLETED:07/19/2021 FOREWORD (PLEASE READ): OCCUPANT LOAD: 6/ 342 DATE PLANS RECEIVED BY ESGIL CORPORATION: 07/01/2021 PLAN REVIEWER: Steven Miller This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2019 CBC, which adopts the 2018 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2018 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process. please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number. specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. CARLSBAD CBC2021-0233 07/19/2021 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: CARLSBAD PREPARED BY: Steven Miller BUILDING ADDRESS: 2511 Gateway Drive BUILDING OCCUPANCY: B, Fl BUILDING PORTION Tl B,F1 Occt.pancy Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code 1 997 UB C Buildin 9 Permit F ! 1997 UBC Plan Check Fee Type of Review: r RepetitiYe Fee -,.. I Repeats • Comments: cb AREA Valuation ( Sq. Ft.) Multiplier 610 46.51 By Ordinance ,.. Complete Review r r· Other Hourly E&Gil F- PLAN CHECK#.: CB-CBC2021-0233 DATE: 07/19/2021 ··--Reg. VALUE ($) Mod. 28,371 - 28,371 J r Structural Only $176.86] Sheet 1 of 1 CARLSBAD CBC2021-0233 07/19/2021 NOTICE: CITY AND ESGIL'S HOURS OF OPERATION ARE AFFECTED BY THE CURRENT COVID-19 EPIDEMIC. PLAN REVIEWER MAY NOT BE AVAILABLE TO ANSWER QUESTIONS BY PHONE, BUT MAY BE REACHED BY E-MAIL AT stmiller@esgil.com . (858) 225-2775 GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to lnterwest and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to lnterwest, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to lnterwest only will not be reviewed by the City Planning, Engineering and Fire Departments until review by lnterwest is complete. 2. Plans may be submitted in electronic format, subject to the jurisdiction's approval. If so, they must have restrictions removed from the security settings. Electronic plans with restrictions to markups, printing, or stamping will not be approved. 3. A reminder that due to Covid-19, the City will not permit counter corrections. Please make sure all the items are satisfied; otherwise, another round of corrections will be necessary. PLANS 4. Please provide a signed copy of the Title 24 ADA Compliance sheet to page A 1 the Title page. Please see a copy of the Compliance Form at the end of the list. 5. Page S 1.2 Detail #20 calls out a detail 13x on page S 1.2 and it is missing from the page please clarify the location of the detail. 6. Page E4-A102 Floor Plan Shows a 1-hour rated wall around the elevator equipment room. Please provide a penetration detail. Also detail how fire-resistive wall construction will be maintained at built-in wall fixtures behind the TV's and bracing for the tv's. CARLSBAD CBC2021-0233 07/19/2021 MECHANICAL 7. Page M1 .2 CF1 R Form shows the conditioned space as 96 sq ft. Please show 610 as the Tl area is 610 sq ft. ADDITIONAL 8. Electrical has been approved. 9. To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 10. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: □ Yes □ No 11. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Steven Miller at Esgil. Thank you. CARLSBAD CBC2021-0233 07/19/2021 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: CARLSBAD PREPARED BY: Steven Miller BUILDING ADDRESS: 2511 Gateway Drive BUILDING OCCUPANCY: B, Fl BUILDING PORTION AREA Valuation ( Sq. Ft.} Multiplier Tl B,F1 Occ14>ancy 610 46_51 ~- Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance t ,.. , 997 UBC Building Permit fee ~ I :•,,I' 1997 UBC P'3n Check Fee _:J Type of Review: Complete Review r Repetitive Fee ~, -~ Repeats Comments: Other Hourly EsGil F- PLAN CHECK#.: CB-CBC2021-0233 DATE: 07/19/2021 Reg. VALUE Mod. ----- Structural Only L----~lHr @* L -------JI ($} 28,371 28,371 $176.86] Sheet 1 of 1 WISEMAN+ROHY STRUCTURAL ENGINEERS STRUCTURAL CALCULATIONS 9915 Mira Mesa Blvd. TEL. (858) 536-5166 FOR Viasat E4 Gem Lab T.I. Carlsbad, CA June 23, 2021 W+R Job #21-038 Suite 200 San Diego, CA 92131 WRENGIN~ 7a/-O~ L\TC Hazards by Location Search Information Address: Coordinates: Elevation: Tlmestamp: Hazard Type: Reference Document: Risk Category: Site Class: 2511 Gateway Rd, Carlsbad, CA 92009, USA ~\. 33.1270859, -117.2638684 312 ft 2021-06-23116:21 :29.9122 Seismic ASCE7-16 II D-default d• .. Google Basic Parameters Name Value Ss 0.957 S1 0.35 SMs 1.149 SM1 * null Sos 0.766 So1 • null * See Section 11.4.8 Description MCER ground motion (period=0.2s) MCER ground motion (period=1.0s) Site-modified spectral acceleration value Site-modified spectral acceleration value Numeric seismic design value at 0.2s SA Numeric seismic design value at 1.0s SA ... Additional Information Name Value Description SDC • null Seismic design category Fa 1.2 Site amplification factor at 0.2s Fv * null Site amplification factor at 1.0s CRs 0.903 Coefficient of risk (0.2s) CR1 0.913 Coefficient of risk (1.0s) PGA 0.417 MCE8 peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.501 Site modified peak ground acceleration l BRESSI .! . _RMap da1a ©2021 II RAM Steel 15.04.00.000 RAMS1rwctura1sysm,1 DataBase: Buildmg 13 T.I gijaenttey-Building Code: IBC Floor Type: MAIN ROOF 0@ ,,--.,_ ~::::::::: ::: . 0 ·········· 0'\ ........ ••· I ~--------···-1 V ; 0)···········+···· (s) '-.;...· 1---::'\ 1 0· ··········r ·· =· 0 © (:"'\ : : : ! .J ; i ~ i :: I ~ , ! Ir • I • • . . . . . . ' . . . ' . . . . . . . . . . . ' 0. (~ ~, rb @ ,_...,, \..J '--' 'C}J ., (~) 0 ' 09/21/17 14:07:59 Steel Code: AISC 360-10 LRFD 0 0 80 . . ... ;.----~-·----.---·-~-· ......... _. ··--------..,_.jal.----------!---...... ~---...... -..... __ ,....... ...... ./7\ G) ___, . .. . t H o o • O rt I I ' ! U O o I • 14 • • • ~ ib ' ' ' 0 1'1'\ '-...../ @10 ~ 0 II RAM Steel 15.04.00.~00 MMslnltbA'lls-,.-DataBase: Bmldmg L, T.I ~!Bentley-Building Code: IBC Surface Loads I . . ' Line Loads Ll Point Loads Pl Label Typ. Roof Roof-Ant. Mech'l Roof Mech'l Unit Label Mech'l Curb Label Add Load DL psf 17.0 33.0 69.0 163.0 DL k/ft 0.067 DL kips 0.000 CDL psf 0.0 0.0 59.5 59.5 CDL k/ft 0.000 CDL kips 0.000 LL Reduction psf Type 20.0 Roof 20.0 Roof 20.0 Roof 0.0 Roof LL Reduction k/ft Type 0.000 Reducible LL Reduction kips Type 1.500 Unreducible Page 2/2 09/21/17 14:07:59 Steel Code: AISC 360-10 LRFD PLL psf 0.0 0.0 0.0 0.0 PLL k/ft 0.000 PLL kips 0.000 CLL MassDL psf psf 0.0 25.0 0.0 31.0 10.0 75.0 10.0 132.0 CLL k/ft 0.000 CLL kips 0.000 MassDL k/ft 0.067 MassDL kips 0.000 TPVA0A0421AA70A & TRUZA0421KA70(N/B)A 42,000 BTU/H MULTI-POSITION AIR HANDLER • TRANE. • MITSUBISHI 42,000 BTU/H HEAT PUMP UNIVERSAL OUTDOOR ., ELECTRIC I Job Name: ~ystem Reference: Date: Indoor Unit. ................................................. TPVA0A0421AA70A Outdoor Unit □ Standard Model.. ..................................... TRUZA0421KA70NA □ Seacoast Model ....................................... TRUZA0421 KA70BA \., .-;.~· \ t~ij INDOOR UNIT FEATURES Ducted air handler provides a solution to cool and heal large zones Highly efficient totally enclosed ECM motor Selectable external static pressure: 0.30, 0.50 and 0.80 ln.WG with 3 fan speeds at each static setting 1 Inch R4.2 fiberglass free insulaUon reduces condensation and boosts efficiency Positive pressure cabinet with air leakage of less than 1.0% at 1.0 in.WG Unique blow through design allows simple coll cleaning when the blower Is removed Multi-position installation: horizontal (left or right), vertical (up or down). For downflow configurations, the CMA-1 Is recommended for proper management of condensate to prevent water blow-off In certain conditions Optional electric heat kit for additional heat capacity Optional humidifier control and ERV control • Multiple control options available: o kumo cloucP smart device app for remote access o Third-party Interface options o Wired or wireless controllers OUTDOOR UNIT FEATURES • Variable speed INVERTER-driven compressor • Power receiver pre-charged with refrigerant volume for piping length up to 100 ft • 24-hour continuous operation (cooling mode) • High pressure protection • Fast restart due to bypass valve make ii ideal for equipment cooling applications, such as data centers Superior energy and operational efficiency Soeciflcatlons are sublect to cha nae without notice. (I)) ?0?1 Mih:uhl,;hl FIA~lrlr. Tmn,, 1-11/Ar. I I~ I I r. All ,;nhlo ,ooon,oA SPECIFICATIONS: TPVA0A0421AA70A & TRUZA0421KA70(N/B}A MCA A 25.0 --MOCP A 31 Fan Motor Ful Load Arnpor•Q~. A o.5 ~o.5 _.., ___ Fan Motor Output w 74 ----•N--Airflow Rate CFM 3880/3880 Refrlgerant Control LEV Oelt0$t Method Reverse Cvda --Coath1 on Hoot Exchanoor Blue Fin Coallna (BS Model ~) Soond Pressure Level, Cooling' d~A~ 52 Soond Pressure Level, Heating' dB(Al 53 OukloorUnll Comoresaor T""" INVERTER~rlv9n twki rotary Comoressor Model MNB33FBRMC-L Compressor Rated l.oed Amie A 8.0 Compressor Locked Rotor Amps A 13.0 Compressor OI Type// Ctiorge oz. FV50S//◄5 External Flnlah Color IVO!Y Muneetl 3Y 7.8/1.1 Bose Pan Heater NIA Untt omenslons W x Ox H: In. [mm) ◄1-5/16 X 13 (+1-3/16) X 52-11/18 (1050 X 330 {+30) X 1338] Packaae Dimensions "u;;'Jt Wek1ht w X DX H: In. [mm] ◄2·15/16 X 17-11/16 X 56-4/16 (1091 X 450 X 1429) Package Weight Cool!~ /lw Tarro {Maldmum / Minimum]' Outdoor Unit Operalt,g Temperature ~aUng Air Temp (Maximum/ Mlnlm<.m)_ Range Heating Thermal Lock-out/ Ro-start Temperatures" ITYPe Re/rlgerant Charoo Chell!elesa Piping L~th Addlttonal Refrioerant Charge Per Additional Plpp_a Lenath Gaa Pipe S110 0.0. [Fl•edJ UqUd Pipe Size OD. [Flared) Piping Maximum PipflO Le,igth Maximum Height Difference "4axlmum Number ol Benda NOTES: AHRI Rated Conditions (Raled data Is determined et e nxed compressor speed) 'Cooing (Indoor// Outdoor) 'Heating at 47'F (Indoor I/ Outdoor) 'Hea&g at 17'F (Indoor I/ Outdoor) Conditions 'Healing at 5'F (Indoor// Oukloor} 'Healing at -4'F ~ndoor JI Outdoor) 'Heatkig at ·S'F (Indoor I/ Outdoor) 'Healtng al -13'F (Indoor// Outdoor) 'OUldoor Unit OporaUng Temperature Range (Cooling As Temp (Maximum/ Mkilmum)): 'F 'F 'F 'F 'F 'F 'F Lbs. 1~9.l Lbs. (kg] 'F 'F 'F lbs, oz Fl[m) oz.IF\.~ ln.[mm] ln.[mm) Fl[m) Ft(ml 80 DB, 67 W8 // 95 DB, 75 WB 70 08, 60 WB 1/ 47 DB, 43 WB 70 DB, 60 W8 // 17 DB, 15 WB 70 DB, 60we//5 DB, 4 WB 70 DB, 60WB//-4 DB, -5WB 70 DB, 60 we// -5 DB, -6 W8 70 DB, 60 we //-13 DB, -14 WB ·-l 21~ J~n '} 245llnJ 115DB/ODB 70 DB, 69WB 1-4 DB,◄ WB -8 /-4 R410A 10,6.0 0.0130.01 0.7 150) -·-······· 5/8 115.88) 3/8 [9.52) 166(~ 1~~1 15 , Appllcetlons should be restr1cted to comfort cootlng only; equipment coottng appllcatlons are llOI recommandod for low ambient temperature condlUons. "Ouldoor Unll Oporating Tempe,eture Range (Cooing Thoonal Lock-out/ Re-start Temperalures; HeeUng Thermal Lock-out/ RHlarl Ta1l'4)811lturas): , System cute out 111 heallng mode to avoid thermlator orror and autornatlcaly restarts at theso temperatur&a. -- ·- -- Speclflcalions are subject to change without notice. C 2021 Mitsubishi Electric Trane HVAC US LLC. All rlahts r8llerved. WISEMAN·+ROHY STRUCTURAL ENGINEERS EQUIPMENT SEISMIC ANCHORAGE (2018 IBC / 2019 CBC/ ASCE 7-16) Version 3.0 PROJECT: Vlasal E4 Tl LOCATION: CU JOB NO: 21-038 6/23/2021 09:21 :55 EQUIPMENT ANCHORAGE PER ASCE 7-1613.3.1 ap = 2.5 Equipment Weight= 250 lb Length (long side)(@ anchors)= 24 In R,, = 6.0 Curb Weight" 0 lb Width (short side)(@ anchors)= 16 In Oo= 1.0 Total Weight= 250 lb(Wp) Sos= 0,766 # Anchors on long side (1 O max) = 2 {24 in oc) Ip= 1.0 Top of Curb to COG= 35 in # Anchors on short side (8 max) = 0 (16 in oc) z = 30 ft {equip ht} Curb Height = 0 In (not counting comers at short sides) h = 30 ft {roof ht) Total Ht to COG= 35 In (HT) Total Anchor Points= 4 Horizontal Component (LRFO) (a) z Fpx = 0,4 n: (Ip)(S0s)(Wp) ( 1 + 2ii) = FpxMIN" 0.3 (S0s) (Ip) (Wp) = F px MAX " 1.6 (Sos) (Ip) (W p) = 0.383 WP 0.383 Wp 0.230 Wp 1.226 Wp Anchor l ayout Vertical Component (LRFD) 0.1532 WP Anchorage Calculations: Strength Level Forces: ASD Level Forces: Mor MR= MNEr Tu= Vu= NOTES: 0.383 Wp = 0.153 Wp = Critical Angle = Fpx •HT= (0.9-FpJ •WP• Lx " (Mor · MR) = 95.8 lb 38.3 lb 0 degrees 3351 lb-In 1494 lb-In (at critical angle) 1858 lb-In (at critical angle) 58 lb Tension/ Anchor (worst case anchor) 24 lb Shear/ Anchor (all equal) Mor= 0.26B WP = 0.107 Wp == Critical Angle = 0 67.0 lb 26.8 lb degrees Fpx •HT= 2346 lb-in MR= (0,6-Fp,J * Wp * Lx = 986 lb-In (at critical angle) MNET= (Mor· MR) = 1360 lb-In (at critical angle) 43 17 lb Tension/ Anchor (worst case anchor) lb Shear/ Anchor (all equal) -This spreadsheet checks all angles (0 deg -90 deg) for each bolt arrangement. Forces given are for the worst-case angle. -Angles are measured up from the horizontal line In the diagram above through the center of the unit (0 deg = right, 90 deg = up). -Attachment to concrete or masonry shall use Omega unless governed by a ductile shear or tensile failure. -If equipment is mounted on vibration isolators with the clearance from equipment to frame > 0.25 Inch use 2Fp (double Sds). -Lx Is the distance to the farthest anchor measured perpendicularly from the angled line of rotation. - SAN DIEGO REGIONAL OFFICE USE ONLY HAZARDOUS MATERIALS RECORD ID I PLANCHECKI QUESTIONNAIRE BP DATE I I Business Name Bualneu Contact Telephone# ViaSal ......,r ~ 7IOll3 100& Project Address (include suite) City State Zip Code APN# 2511---CA -213-280-07 Malling Address ~nclude suite) City Stele Zip Code Plan File# 211-ltG-07 -CA -Project Contact Applicant E-mail Telephone# -Tu _ ....... _..._.m The folloWlng q....a-...,......i Iha faclllty'• ac:tlvltlas, NOT the spaclllc proJect dasalpllan. : I ng , your use, precess. or ""'8 any nt m .. t ccnteet the fire Pmtectlon AtJe,V:,/ with jurisdiction pnor to plan submittal. OCCUpsncy Rating: Faclllty's Square F-. (Including proposed p,ojecl): 1. Elcpioai11e or Btuting Agents 5. Organic Peroxklea 9. w-Raactives 13. Corrooivel 2. Compressed Gala 6. Olddizera 10. Clyogenlca 14. Other Health Hazards 3. Flammable/Combuatible Liquids 7. Pyrophorlca 11. Highly T oxlc or Toxic Materials 15. None al Thasa. 4. Flammable Solids 8. u .. 1e111e Rea-12. Radioactives PART 11: ft: D1E.:2.frn1NTY..!!a~~OF ENVIRON~H~TH -~~t: DM~ft H the anaww to any of the quii&oni yes, n muit the of San CNego sreriiii , venue, 1 , Diego, CA 92123. Cell (858) 505-8700 prior to the ialuanal al a bul ing pennlt. FEES ARE REQUIRED Project Completion Date: E,.._ted Date of Occupancy: □ CelARP Exempt 1. 2. 3. 4. 5. 6. 7. 8. YES NO (for MW construction or remodeling projects) § I la your bu1inasa ll118d on the ,._ aide al this form? (check all thal apply). • WII your buslneu dispose of Hazardous Subotences or Medical Waste In any amount? Will your business store or handle Hazanlo .. Subotenceo In quantlllel g..-lhan or equal to 55 gallons. 500 pounds and/or 200 aJblc __, ! I Will your buslnasa ""'8 or handle can:inogens/repraductive toxins In any quanllly? • Will your business use an ulating or lnalall an unde<ground atorage tank? • Wlft your business ""'8 or handle Regulated Subotences (CelARP)? WMI your buslnasa use or inatall a Hazardaul W-Tank Sy■tem {Tllle 22, Article 1 0)? WII your business store peln>laum In tenkl or ccntelne111 al your faclllly with a total facllly storege capactty equal to or greater than 1,320 gallons? (Cellfornla"a Aboveground P-..n Storage Act). Dale 0 CelARP Required Dale 0 CelARP Complete Dale r-1° m:~ DfEQP coue ~ c~ QISTRlCJ 1z..iThe 1o11ow1ng quastlona are Intended to Identify the majority a1 air pallutlon rm atannlng atage. our mayraq re mea■urea ~ by lhess q-tionl. Some --~maybe exempt tram APCO requirements. If yes ts answered either questions 1, 2 01 5 or for more comprehen■tve requirements, please contact APCO ·a1 aocdcomo@sdcountv.ca.gov; (858) 588-2650; or 10124 Old GRMI Road. San Diego, CA 92131. YES NO Will the p,ojecl disturb 100 square -or mare of exlallng building materials? WII any load 1upportlng llruclural mamberl be removed? i ~ ~ 4. □ (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Hu an a-toa 1urvey been performed by an Individual thal has paued an EPA-approved building Inspector caunie? 5. □ □ 6. I!] (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Bued on the survey re1ulls, will the project disturb any -tao containing material? H l/91. a notification may be required at -10 wondng day■ prior to commencing uboatol removal. Addltionally. a notiftcallon may be required prior to the remllWII of a load 1upporting llruetural mambe<(1) regardleu al the presenca of ubeltao. I!] Will the project or naociatad construction equipment emtt air ccntemlnantl? Sae the revenie 11de al this form for typical equipment requiring an APCD penntt. If yea, contact APCD pnor to the isauanca al a bultdlng pennll 0 (ANSWER ONLY IF QUESTION 5 IS YES) Will tha p,ojecl or aaaoclated con■truction equipment be located within 1,000 -al a - bounda Brlelly describe bualne11 activities: Briefly describe proposed project: Offlco- I -re under penalty al pe,ju,y that to the beat of my knowledge end bel ., / 1, Nama of Owner or AuthoriZed nt Date FIRE DEPARTMENT OCCUPANCY CLASSIFICATION· BY: DATE: I I Em..-T 01t NO FURTHEII INFOIIIIATION REQUIIIED REI HIED FOR ■ULDNG NIUllf ■ur NOT FOR OCCUPANCY REI IHID FOIi OCCUPANCY COUNTY-HMO' APCO COUNTY-HMO APCO COUNTY-HMO APCO .:>,,on Co,,t. ,l~ ---o,.. ... R.ev,eweo "2 ii. 01/lt/Uc.Al.f '° OAt~/Jrul1,'llS <' J'.-,1) (("If Diego • A stamp In this box !!lllx exempts businesses lrom cornptallng or updating a Hazardaua Materials Busineal Plan. Other perrnllllng requirements may still apply HM-9171 (9118) County of San Dlagc • DEH • Hazardous Materials Division ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com Date: 6/20/2021 Business Name: Viasat Building E4 Street Address: 2511 Gateway Drive Email Address: danat@sca-sd.com PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) [2] Check all below that are present at your facility: D O Acid Cleaning Assembly 0 Automotive Repair O Battery Manufacturing D O Biofuel Manufacturing Biotech Laboratory 0 Bulk Chemical Storage O CarWash D O Chemical Manufacturing Chemical Purification 0 Dental Offices D Dental Schools O Dental Clinics 0 Dry Cleaning 0 Electrical Component O Manufacturing O Fertilizer Manufacturing O Film/ X-ra y Processing 0 Food Processing 0 Glass Manufacturing 0 Industrial Laundry O Ink Manufacturing O Laboratory 0 Machining/Milling 0 Membrane manufacturing O (i.e. waterfilter membranes) O Metal Casting/Forming 0 Metal Fabrication 0 Metal Finishing 0 Electroplating 0 Electroless Plating 0 Anodizing 0 Coating (i.e. phosphating) 0 Chemical Etching/Milling 0 Printed Circuit Board O Manufacturing 0 Metal Powders Forming 0 Nutritional SupplemenWitamin 0 Manufacturing O Painting/Finishing O Paint Manufacturing 0 Personal Care Products 0 Manufacturing O Pesticide Manufacturing/ Packaging O Pharmaceutical Manufacturing 0 (including precursors) 0 Porcelain Enameling D Power Generation 0 Print Shop 0 Research and Development 0 Rubber Manufacturing 0 Semiconductor Manufacturing 0 Soa·p/Detergent Manufacturing O Waste Treatment/Storage New Business? YesONoEI SICCode(s) if known: Date operation began/will begin: ______ _ Tenant Improvement? Yes EINoO If yes, briefly describe improvement: renovation of existing office space Description of operations generating wastewater (discharged to sewer, hauled orevaporated):_n_o_c_h_a_n_g_e _____ _ Estimated volume of industrial wastewater to be discharged (gal/ day) : _n_o_c_h_a_n_g_e ________________ _ List hazardous wastes generated (type/volume): ____________________________ _ Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? YesODate: _____ ,No□ Page 1 of 2 ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com The commercial enterprises listed below are a partial listing of businesses that are exempt from industrial wastewater discharge permitting under normal operating conditions. They are exempt because (a) they discharge no process wastewater (i.e., they only discharge sanitary wastewater with no pollutants exceeding any local limits), and (b) they have no potential to negatively impact the EWPCF or other wastewater treatment plants in the ESS. Any questions regarding exemptions should be referred to EWA Source Control staff. □ Automobile Detailer s □ Hotels/ Motels (no laundry) □ Barber/Beauty Shops □ Laundromats □ Business/Sales Offices □ Libraries □ Cleaning Services □ Medical Offices (no x-ray developing) □ Carpet/Upholstery □ Mortuaries □ Childcare Facilities □ Museums □ Churches □ Nail Salons □ Community Centers □ Nursing Homes □ Consulting Services □ Office Buildings (no process flow) □ Contractors □ Optical Services □ Counseling Services □ Pest Control Services (no pesticide repackaging for sale) □ Educational Services (no auto repair/film developing) □ Pet Boarding/Grooming Facilities □ Financial Institutions/Services □ Postal Services (no car wash/auto repair) □ Fitness Centers □ Public Storage Facilities □ Gas Stations (no car wash/auto repair) □ Restaurants/Bars □ Grocery Stores (no film developing) □ Retail/Wholesale Stores (no autorepair/film □ Residential based Businesses developing) □ Theaters (Movie/Live) CERTIFICATION STATEMENT ation above is true and correct to the best of my knowledge. Dana Tsui Print Name: ____________ _ 6-21-2021 Date: ____ _ Facility Contact: ___________ _ Title: _____________ _ ENCINA WASTEWATER AUTHORITY 6200AVENIDA ENCINAS, CARLSBAD, CA Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com Page 2 of 2 ( City of Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of permits are not required to fill out this form ❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool .A If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. .A Details on CAP ordinance requirements are available on the city's website . .A A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and download the latest form. Project Name/Building Permit No.: Viasat Building N4 BP No.: Property Address/APN: 2548 Campbell Place Applicant Name/Co.: Dana Tsui/ SCA Architecture Applicant Address: 13280 Evening Creek Drive Suite 125 Contact Phone: 858-793-4777 ContactEmail: danat@sca-sd.com -"--------:;;,""---.c- Contact information of person completing this checklist (if different than above): Name: Company name/address: Contact Phone: Contact Email: Applicant Signature: _c:_,_,·...,,)-"OUJL-=-=-~--1;\c/-·· .... ·c'--------Date: 5-24-2021 j B-50 Page 1 of6 Revised 06/18 City of Carlsbad Climate Action Plan Consistency Checklist Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For alterations and additions to existing buildings, attach Building Permit Valuation worksheet. Building Permit Valuation (BPV) from worksheet: $_16_,8_75 ____ _ 0 Residential □ New construction D Additions and alterations: □ BPV < $60,000 □ BPV;, $60,000 □ Electrical service panel upgrade only □ BPV;, $200,000 I!] Nonresidential □ New construction ro Alterations: □ BPV;, $200,000 or additions ;, 1,000 sauare feet □ BPV;, $1,000,000 □ "2,000 sq. fl. new roof addition A high-rise residential building Is 4 or more stories, Including a Low-rise High-rise mixed-use building in which at least 20% of Its conditioned floor N/A 1A,4A 1A, 4A' 11B, 2B, 3B,4A N/A 4A 1B, 4A' 1B, 2B, 3B, 4B and 5 J 1B, 5 1B,2B,5 2B,5 area Is residential use All residential additions and alterations 1-2 family dwellings and townhouses with attached garages only 'Multi-family dwellings only where interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are prooosed Building alterations of;, 75% existing gross floor area 1 B also applies W BPV;, $200,000 . • < • ' .·' ' .'.i ,· : ' ~ ' _,·:.r '.::,_: !o•· : : '-.;.;.~if ,:~~;j\: . ~ : \i +: . ;· _; <. ' 1. Energy Efficiency Please refer to Cartsbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building S1andards Code (CALGreen) for more information when completing this section. A. D Residential addition or alteration ~ $60,000 building pennlt valuation. □ NIA _______ _ See CMC section 18.30.190. D Exception: Home energy score ~ 7 (attach certification) Year Built Silgle-famlly Requirements Multl.famlly Requirements □ Before 1978 Select one: a Duct sealing □ Attic insulation a Cool roof □ Attic insulation D 1978 and later Select one: □ Lighting package a Water heating Package □ Between 1978and 1991 Select one: □ Duct sealino □Attic insulation □Cool roof D 1992 and later Select one: □Lighting package □Water heating package B. D Nonresldentlar new construction or alterations ~ $200,000 building pennlt valuation, or additions~ 1,000 square feel □ NIA Updated 8/15/20 I 9 2 City of Carlsbad Climate Action Plan Consistency Checklist See CMC 18.21.155 and CAL Green Appendix A5, Division AS.2-Energy Efficiency. A5203.1.1 Choose one: D .1 Outdoor lighting □ .2 Warehouse dock seal doors [I .3 Restaurant mce water heating (comply v.ilh California Energy Code section 140.5, as amended) □ NIA _________ _ D .4 Daylight design PAFs [] .5 Exhaust air heat recovery AS.203.1.2.1 Choose one as applicable: 095 Energy budget □.90 Energy budget □NIA AS.211.1" □ On-site renewable energy □NIA AS.211.3" □ Green power (W offered by local utility provider, 50% minimum renewable sources) □NIA AS.212.1 D Elevators and escalators □ NIA AS.213.1 D Steel framing □ NIA • Includes hotels/motels and high-rise residential buildings " For alterations ~ $1,000,000 8PV and affecting > 75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply Ymh CMC 18.30.130 instead. 2. Photovoltaic Systems A. ~ntial new construction (for low-rise residential building pennlt applications submitted after 1/1/20). Refer 1o 2019 California Code section 150.1 (c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic requl~~) Instead. 2) If project Includes installation of an electric heat pump water heater pursuant to CMC 18.30.150(8) (high-rise resld or 18.30.170(8) (low-rise residential), Increase system size by .3kWdc if PV offset option Is selected. Floor Plan ID (use additional CFA~ #d.u. Calculated kWdc' Exception sheets ~ necessary) '- ~ □ I'----..._ □ ......______ □ ........__ -□ Total System Size: kWdc -----. kWdc = (CFAx.572) / 1,000 + (1.15 x #d.u.) ~ 'Fonnula calculation where CFA = conditional floor area, #du= number of dwellings per plan type If proposed system size is less than calculated size, please explain. B. 0 Nonresidential new construction or atterations i!$1,000,000 BPV and affecting ~75% existing floor area, or addition that increases roof area by ~.ooo square feel Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to hlgMlse residential and hotel/motel buildings. n/a Choose one of the following methods: □ Gross Floor Area (GFA) Metihod GFA: Min. System Size: __ kWdc D If< 1 O,OOOs.f. Enter: 5 kWdc 011 ~ 10,000s.f. calculate: 15 kWdc x (GFA/10,000) " "Round building size fac1or to nearest tenth, and round system size to nearest whole number. □ Time-Dependent Valuation Method Updated 8/15/2019 3 City of Carlsbad Climate Action Plan Consistency Checklist Annual TDV Energy use:-______ x .80= Min. system size: ____ _ kWdc •~Attach calculation documentation using modeling software approved by the California Energy Commission. 3. Water Heating A. esidential and hotel/motel new construction Pie refer to CMC sections 18.30.150 and 18.30.170when completing this section. ing Individual dwelling units choose one: O Heat pump wa eater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) O Heat pump water heater A PV system .3 kWdc larger than required in CMC section 18.30.130 (high rise residential hotel/motel) or CA Ener Code section 150.1(c) 14 (low-rise residential) 0 Heat pump water heater meeting N dvanced Water Heating Specification Tier 3 or higher O Solar water heating system that is either . olar savings fraction or 40 s.f. solar collectors D Exception: D For systems serving multiple dwelling units, install a central water-ating system with all of the following: D Gas or propane water heating system □Recirculation system per CMC 18.30.150(6) (high-rise residential, hotel/mo rise residential) D Solar water heating system that is either: D .20 solar savings fraction D .15 solar savings fraction, plus drain water heat recovery D Exception: B. D Nonresidential new construction n/a no water heating Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section. D Water heating system derives at least 40% of its energy from one of the following (attach documentation): D Solar-thermal D Photovoltaics O Recovered energy □Water heating system is (choose one): □ Heat pump water heater □ Electric resistance water heater(s) □Solar water heating system with .40 solar savings fraction D Exception: Updated 8/15/2019 4 City of Carlsbad Climate Action Plan Consistency Checklist A. lal New construction and major alterations* d Ordinance CMC section 18.21.140when com One and two-ily residential dwelling or townhouse with attached garage: D One EVSE Rea O Exception : D Multi-family residential: Total Par1<ing Spaces Pro osed 0 Exception : EVSES aces Calculations: Total EVSE spaces= .10 x Total parking (rounded up to nearest wh ber) EVSE Installed = Total EVSE Spaces x .50 (rounded up to nearest whole nu EVSE other= Total EVSE spaces -EVSE lnstaUed (EVSE other may be "Capable," "Ready" or "Installed.") Installed Total 'Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a bu,="lll-""nnlt valuation~ $60,000 or indude an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), altera ve a building pennit valuation~ $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or ·ng systems are proposed. B. @ Nonresidential new construction (Includes hotels/motels) (!] Exception · <1000 sf of tenant improvement Total Pari<ing Spaces EVSE Snaces Pronn•....t Caoable Readv I Installed Total I Calculation-Refer to the table below· Total Number of Parkina Snoces orovided Number of ""'Uired EV Snoces Number of ""'Uired EVSE Installed S""""" r 0-9 1 1 □ 10-25 2 1 r 26-50 4 2 □ 51-75 6 3 I 76-100 9 5 101-150 12 6 151-200 17 9 201 and over 10 ""rcent of total 50 =rcent of R=uired EV Soaces Updated 8/15/2019 5 Gity of Carlsbad Climate Action Plan Consistency Checklist 5. D Transportation Demand Management (TOM): Nonrealdentlal ONLY An approved Transportation Demand Management (TDM) Plan is required for all nonresidential projec1s that meet a threshold of employee-generated ADT. City staff will use the table below based on your submitted plans to detennine 1'111ether or nor your permit requires a TDM plan. WTDM is applicable to your permit, staff will contact the applicant to develop a site-specific TDM plan based on the pennlt details. Acknowledgment Employee ADT Estimation for Various Commercial Uses Use EmpADTfor first 1,000 s.f. EmpADTI 1000 s.f.1 Office (all)2 20 Restaurant 11 Retail• 8 Industrial 4 Manufacturing 4 Warehousin 4 1 Unless otherwise noted, rates estimated from /TE Trip Generation Manual, 10'•Edition 13 11 4.5 3.5 3 1 2 For all office uses, use SAN DAG rate of 20 ADT/1,000 sf to calculate employee ADT • Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration Sample calculations: Office: 20,450 sf 1. 20,450 sf/ 1000 x 20 = 409 Employee ADT Retail: 9,334 sf 1. First 1,000 sf= 8 ADT 2. 9,334 sf -1,000 sf= 8,334 sf 3. 8 334 sf/ 1 000 x 4.5 + 8 = 46 Em lo ee ADT I acknov.iedge that the plans submitted ma be · to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should my permit require a TDM n and unde nd a an approved TDM plan is a condition of pennit issuance. Date: <t{u,}UJZJ Pelson other than Applicant to be for TDM compliance (If applicable): Name (Printed): __ _,<.._,)....,e.c.c~""Je ..... ,.,,tv\' ... Y..__n\n-1-'-'-'-""'"-'l P...,D ... o.,_.J.,,._ __ _ Phone Number: ____ _ Email Address: ,Jf!e:£ MY. 1H:OM.f',So~I ~ ,/IP§,b.t .ca M Updated 8/15/2019 6