HomeMy WebLinkAboutCT 2018-0006; LAGUNA DRIVE SUBDIVISION; HYDROLOGY AND HYDRAULICS REPORT; 2020-06-04RECORD COPY
CT2018-0006
Laguna Drive
Subdivision
Carlsbad, CA
92008
Hydrology and
Hydraulics Report
Presented to the City of Carlsbad
For Grading Permit Processing
Rrrn1qj)
JUN 2z
LAND DE C. .
ENG j,\E NT
Prepared for
Brett Farrow Architect
June 4, 2020
Prepared By:
CJE
Cory Jones Engineering
1820 S. El Camino Real, Unit A205
Encinitas, CA 92024
QISP ToR, ENV SP
Cory Jones, PE, QSD/P,
If
OESSIOk
(NoC698O7
Eip.05/30/20
CIV
OF C
"
.....
This Drainage Report (Report"):
has been prepared by Cory Jones Engineering (CJE) for Brett Farrow Architect (BFA) with the intended use
of supporting the City of Carlsbad grading permit application;
may only be used and relied on by the BFA;
must not be copied to, used by, or relied on by any person other than the BFA without the prior written
consent of CJE;
may only be used for the purpose of evaluating site drainage (and must not be used for any other purpose).
WE and its servants, employees and officers otherwise expressly disclaim responsibility to any person other than the
BFA arising from or in connection with this Report.
To the maximum extent permitted bylaw, all implied warranties and conditions in relation to the services provided by
WE and the Report are excluded unless they are expressly stated to apply in this Report.
The services undertaken by WE in connection with preparing this Report:
were limited to those specifically detailed in the project scope of work;
did not include study of off-site drainage pattern or hydromodiflcation.
The opinions, conclusions and any recommendations in this Report are based on assumptions made by WE when
undertaking services and preparing the Report ("Assumptions"), including (but not limited to):
Existing storm drain facilities were sized to function properly.
This project intends to address the potential additional surface runoff created by proposed changes to the
nature of the structures and pervious and impervious areas on the subject site property.
The report will study on-site flows and on-site flows. No off-site flows were considered.
Proposed discharge will be sized to maintain the discharge capacity as the existing points contributing
discharge to Laguna Drive.
WE expressly disclaims responsibility for any error in, or omission from, this Report arising from or in connection with
any of the Assumptions being incorrect.
Subject to the paragraphs in this section of the Report, the opinions, conclusions and any recommendations in this
Report are based on conditions encountered and information reviewed at the time of preparation and maybe relied
on for one year or till significant changes to the project site are made, whichever comes first, after which time, WE
expressly disclaims responsibility for any error in, or omission from, this Report arising from or in connection with
those opinions, conclusions and any recommendations.
Page i
Table of Contents
Purposeof Study.....................................................................................................
HydrologicAnalysis.................................................................................................
Hydraulic Analysis .
Figures
Figure 1 Vicinity Map /
Appendices
Appendix A Rational Hydrology Workmap (Pre- and Post-Construction)
Appendix B Rational Hydrology Analysis
Appendix C Isopluvial Maps
Appendix D Project Drainage Area Schematics
Appendix E Hydraulic Calculations, Existing and Proposed Conditions
Appendix F Reference Materials from Geotechnical Report
Appendix G FEMA FIRM Panel
I
5
9
Page ii
Declaration of Responsible Charge
I hereby declare that I am the Engineer of Work for this project, that I have exercised responsible
charge of the design of the project as defined in Section 6703 of the Business and Professions
Code, and that the design is consistent with current standards.
I understand that the check of project drawings and specifications by the City of Carlsbad does not
relieve me, as Engineer of Work, of my responsibilities for project design.
Firm: Cory Jones Engineering
Address: 1820 S. El Camino Real, Unit A205
City, State: Encinitas, CA
Telephone: 619.884.0576
By: Con' Jones, PE
Date: 6/4/2020
R.C.E. #: 69807
Registration Expiration Date: 6/30/2020
Page iii
Purpose of Study
This Drainage report presents the hydrologic conditions for the proposed 570 Laguna
Drive project in Carlsbad, CA. This report also provides an evaluation of the pre-
construction and post construction on-site drainage conditions for hydraulic requirements
to meet the standards of the City of Carlsbad. This report also addresses water quality
requirements specifically requested by the City of Carlsbad Engineering Standards and
required by the National Pollutant Discharge Elimination System (NPDES) Permit and
Waste Discharge Requirements for Discharges from the Municipal Separate Storm Sewer
Systems (MS4s) Draining the Watersheds within the San Diego Region (California
Regional Water Quality Control Board, San Diego Region Order No. R9-2013-0001, as
amended by Order No. R9-2015-0001 and R9-2015-0100, NPDES No. CAS0109266).
Project Location
The Laguna Drive Subdivision project is located in the coastal area of the City of Carlsbad,
just south of Buena Vista Lagoon and just north of Laguna Drive between the intersections
with State Street and Roosevelt Street/Buena Vista Circle at 570-580 Laguna Drive. The
property is located on Assessor's Parcel Number (APN) 155-221-12. A Vicinity map
showing the project's location is provided in Figure 1.
I I Page
WE
Project
Location
C o
The (,rt,T,
CA
1auna Dr.
9
ow 4j Buena Vista Lagoon
Figure 1 — Vicinity Map
Project Description
The Laguna Drive Subdivision project consists of demolition of one existing building at
570 Laguna Drive and removal of a building at 580 Laguna Drive and subdivision of the
existing Lot into two lots, one with 13 new residential condominium units and one open
space lot. There is an existing commercial driveway and asphalt parking lot adjoining the
existing building at 570 Laguna Drive. The driveway will be relocated to a centered
location on the newly subdivision lot. The driveway and multi-use drainage facilities that
will be built as part of this project will be maintained by the Home Owners Association
(owned by "Laguna Project, LP" with the HOA Entity titled "Laguna Row" and managed
by Mr. Brett Farrow).
The project existing and proposed conditions site soils information are described in Figure
2. The soils types as depicted from the NRCS Web Soil Survey were confirmed by on-
site soils testing results presented in the project Geotechnical Report (See Topo Plat and
Cross Section A-A provided therein and provided herein within Appendix G). From the
2 J P a
CJE
borings and soils descriptions, the materials consist of approximately 2 to 2.5-feet of top
soil described as fine grained sand, silty, and organics, underlain by 16.5 to 17.5 feet of
paralic deposits described as fine, medium, and coarse-grained sand, pebbles, and
gravel-pebble layers, and Santiago Formation (considered a clayey sandstone). The
upper two layers are considered Hydrologic Soil Type B (e.g. well draining soils). The
Santiago Formation is considered a consolidated bedrock that may be considered a
Hydrologic Soil Type C or D. The locations of the bottom of the low impact design
infiltration based BMPs will be released within the effective area of the Hydrologic Soil
Type B materials and therefore this material type is used throughout the preparation of
this report.
Note that NRCS does not have a
classification for LG-W and TeF areas,
but from the Preliminary Geotechnical
Soil Type: LG-W. Investigation provided by Coast
Lagoon Water Geotechnical, indicate that the site
consists of:
- 2 to 2. 5-ft thick top soil layer of
Soil Type: Tel:. . reddish dark brown, fine grained,
Terrace extremely well sourted, moderately
Escarpments dense sand, over
- 17 to 18-ft of Old Paralitic Deposits
that consists of sediments that are light
brownish tan to red brown fine-grained
sandstone, well sorted, dense, slightly Soil Type: MI( . .. i moist and contain rounded gray pebbles, Marina Loam'
- Coarse Sand 9 -
over
percent slopes -
Santiago Formation bedrock that
includes interbedded sands and clays
I. -. .
and extend to the maximum borehole
I depth of at least 50-ft below ground
-•-
surface (bgs).
31 P a g
CJE
An infiltration test was taken from a location in the frontage of the proposed development
using the double-ring infiltrometer test at an estimated elevation of approximately 42-feet.
The infiltration rate observed at this location was estimated to approach 2.48 inches per
hour, which infers that the site may be good for infiltration of site drainage waters.
However, the Geotechnical Engineer provided the following caveats:
"The geologic conditions underlying the rear bluff are such
that infiltrated water developing saturated conditions can adversely
affect slope stability. Storm water infiltration should be significantly
limited and, if necessary, bioretention basins should be located in the
most southern portion of the site."
and
"In general, pad water should be directed away from foundations and
around the structure to the street. Roof water should be collected and
conducted to the street via non-erodible devices. Pad water should
not be allowed to pond. Vegetation adjacent to foundations should
be avoided. If vegetation in these areas is desired, sealed planter
boxes or drought resistant plants should be considered. Other
alternative may be available; however, the intent is to reduce
moisture from migrating into the foundation subsoils. Irrigation
should be limited to that amount necessary to sustain plant life. All
drainage systems should be cleaned annually, prior to winter rains."
41Pae
Surrounding Land Uses
The area is urbanized and the surrounding properties consist of commercial, single family
and multi-family residential uses and is located near the old Carlsbad business district
along the old Highway 101.corridor, now Carlsbad Boulevard.
The project does sit adjacent to the Buena Vista Lagoon, but the development is not
planned to encroach close to the habitat area along the bluff. As seen from the FEMA
FIRM Panel Number 06073C0761 H, the project development limits is within the Zone X
area appears a minimum of 200-feet from the floodplain. See panel in Appendix H.
51 Pane
JE
Hydrologic Analysis
This drainage study utilizes the Rational Method to calculate peak flow rates for the 10
and 100 year storm events. The Rational Method is appropriate for sites with watersheds
smaller than 0.5 square miles and is described in detail within the County of San Diego
Hydrology Manual (2003 Ed). This report is using the AES software, approved by the
County of San Diego, to evaluate rational method hydrology estimates for the project site.
Rational Method Runoff Coefficients
For this drainage report, each drainage sub-area basin was determined to have a percent
imperviousness based on existing and proposed conditions mapping. This percent
impervious was used to select a given land use type with similar percent imperviousness.
Therefore, the land uses presented for each sub-basin area are different.
To provide conservative estimates of peak flow rates, the pre-development condition land
use types were selected with land uses that have the same percent imperviousness or
slightly less and the post-development condition land use types were selected with land
I
uses that have the same percent imperviousness or slightly greater. In this way, the post-
development peak flows will be exact or slightly skewed with higher rates and the pre-
development peak flows will be exact or slightly skewed with lower rates. Therefore,
matching of peak flows to the existing discharge points can be evaluated and may provide
additional comfort with this conservativism.
6Page
Table I in Appendix B presents each drainage area sub-area square footages for
pervious and impervious areas and their correlated percent imperviousness and shows
the corresponding land use type selected and it's percent impervious value used in the
AES model.
Intensity
Intensity for the 10 and 100 year storm frequencies was using isopluvial maps from the
County of San Diego Hydrology Manual (see Appendix C).
Peak Flow Rates and Volumes
Peak flow rates were estimated using the rational method as evaluated by the AES model
and program results along with summary tables of the results are presented in Appendix
B.
The appendix includes the following documents related to peak flow estimates:
Appendix A contains Maps of the site drainage (existing and proposed conditions),
Appendix B contains Calculations of hydrology summations to each node (inlets or
other collection locations),
. Appendix D contains drainage schematics for existing and proposed conditions.
Appendix E contains summations for flow to each sub-area node and node
summations.
Appendix F contains Hydraulics for conveyances (pipes and channels).
7lPage
Table 1. Comparison of 100-Year Peak Flow Rates at Discharge Locations
Flow Direction QIOO pre
(cfs)
Q100 post
(cfs)
Delta
(cfs)
Evaluation
North 1.27 0.36 -0.91 No impact
South 1.12 2.14 to Storm +1.19 total Per discussion
Drain w/o (without with City, storm
infiltration infiltration) I drain can
system I +2.14 to storm accept this
0.17 to Laguna drain pipe I flow.
Drive Curb and +0.27 cfs to
Gutter System street (this
from parkway / addition to
1.39 cfs to C&G street does not
as pipe under account for
pressure pipe infiltration
P15 has losses within
capacity of subgrade rock
approximately gallery BMP).
0.97 cfs
Based on our analysis, the site appears to reduce peak storm discharges from the facility.
This is likely due to additional time of concentration added by the added site conveyance
around the new proposed structures combined with the well draining soils in the vicinity
of the project site as well as the addition of the pervious pavement system that captures
and infiltrates rainwater, thus reducing the peak 100 year storm flow and capturing and
infiltrating the water quality design capture volume required to comply with the WQMP.
A triangular hydrograph was assumed to have a peak flow of 1.30 cfs from the developed
project over a 6-hour duration. This value is divided in two to provide a worst case peak
volume produced of 14,040 CF. This is conservative because the triangular technique is
typically applied over 2 times the time of concentration.
8IPage
WE
The infiltration subgrade is 2,407 SF in area. The design infiltration rate is 1.24 inches/hr.
Therefore, the subgrade infiltration basin will infiltrate approximately 1,492 CF in 6 hours
or only 746 CF assuming a half clogged condition.
The subgrade infiltration basin can contain 3,710 CF of water in the pore space, therefore
this value plus the value infiltrated over the storm reduces the peak storm volume to pass
through the site to a value of approximately 9,584 CF or 68% of the total storm.
Results Statements
Flow was determined to not increase from pre-construction to post-construction condition
as demonstrated by calculations providing a capture volume equal to the estimated 100
year peak storm volume using the triangular hydrograph technique (using a duration
equal to the time of concentration).
Flow rates are compared at both points of comparison (drainage north to Buena Vista
Lagoon and drainage to the Laguna Drive gutter just SW of the property.
From results of our study, there are determined to be no negative impacts to any adjacent
properties.
9IPage
WE
Hydraulic Analysis
Methodology
Hydraulic flow calculations and storm drain facility sizing were performed using the
procedures outlines in the County of San Diego Drainage Design Manual (2014 Ed).
Hydraulics
Hydraulic capacities were evaluated for new and existing storm drain inlets and piping
and these evaluations are provided in the attached calculations.
On-site catch basins are sized to accept the 100 year peak discharge to their interior site
drainage locations. These boxes are sized as weirs with length defined as the perimeter
length of the boxes and assuming a clogging factor of 50% since they will be installed
with an inlet filter system to assist in reducing the quantity of solids that will pass to the
sub-grade rock reservoir infiltration gallery.
Pipe capacities are evaluated with Manning's condition assuming open channel flow I
conditions with steady uniform flow.
Design Review
From review of the estimated peak flow rates for the 100-Year design storm, the proposed
new pipes and inlets will provide adequate capacity to drain the property during these
storm events.
Water Quality
The project is a Priority Development Project and therefore it is subject to design
requirements for treatment controls. The project provides water quality volume for the 85th
1OIPae
JE
percentile storm (Design Capture Volume) as demonstrated in the calculation tables
provided in a separate report titled Storm Water Quality Management Plan for Laguna
Drive Subdivision.
The project disturbs less than one acre during construction and therefore does not require
a state permitted SWPPP per the Construction General Permit. However, the final project
grading plan will include an erosion and sediment control plan to comply with City
regulations.
The project drainage does not adversely affect any existing US Army Corps of Engineers
jurisdictional waters of the United States. The project re-directs a limited amount of
drainage away from the bluff (that directly discharges to Buena Vista Lagoon) and drains
it to Laguna Drive (which is safely conveyed to Buena Vista Lagoon without impact)
Therefore, the project is not required to obtain approval from the Regional Water Quality
Control Board under Federal Clean Water Act (CWA) Section 401 nor Section 404.
ii I Page
Page Left Intentionally Blank
WE
WE
Page Left Intentionally Blank
IWE
APPENDIX A
RATIONAL HYDROLOGY WORKMAP
WE
I
Page Left Intentionally Blank
WE
rAlOR 0.01 INLET 10 -
/
0.02 0.07
TG 44.95' Al 1 R 01
INLET 11 (1 2 .01
TG 44.96 TG 44 75
IN
2.2
Q1O=0
TG 45.05'
INLET 12
I
Qloo=s003 013
IE 43.60' '0*03 (Al
EE01 54 43
Pi P2 P3
L=18' -
.O/ 451 Q10=0.09CFS
1.1 L I
-5 5.2 - -
L=35'
.. Q100=O.15CFS
44.95
71
44±
// A(1) .03
542
Ll
010 015 1 2
4505
4:.:6
- --
/ 4502
/ 46.18 •
-
~A 01)
6.5
rAl 3R 0. 03 6.4 c r D
6.1 2.1
0.04006 Cb
0.04 0
46.16
3.040.0
44.71
OIS
HARGF
1.2
37
4635 -22 0.3 /
C45,. '
A(2
INLET 13 6
0
661
INLET
1.3
45
;,
jç9 v
Ql
-Q 2
7
=1 07
T
rA(l 9)0.28
G :No;
/
64
/
212
V V
V
-
v1o =
44.8 IE 42.20 44.8 15
LI IF v
45.31
TG 4440
BOW
76.5 v
10
44.29
Ll
44.53 25
ro.
.
,
0.030.
1.1
DISCHARGE POINT 1 (SOUTH)
Q100
43.33
DISCHARGE POINT NORTh)
46 65± 450±
V 004 006
Q100=0.36 CFS
S S
1
P1
-
S
DEPTH<0.25 FT
V100=0.60 FPS, NORMAL DEPTH '0-01- T
\ N
N
N
NN\\
N
4.2 41
45.5'± rA(18)0.01 46.31'±CLEANOUT
LEGEND
(PER FIG-3-6 SDCHM) / I
4r39
Q100= 1.39 cfs(EST. PER PIPE
SURCHARGE-.+ PARKWAY)
V100=2.5FPS H
DEPTH' = 0.24 FT INLET 9B
A913 .01 TG 43.10' 7.4 (PER FIG-3-6 SDCHM)
IE 41.95'
0.01 0.02) Qi 0=0 01 CFS 43 29
9.4 Qi 00=0.02CFS
I
43.10 1)
Am 0 EXHIBIT 2 - RATIONAL HYDROLOGY WORKMAP
0 10' 20' POST-CONSTRUCTION PROJECT AREA MAP
570-580 LAGUNA _DRIVE, _CARLSBAD,_CA
1 INCH = 10 FT LEGEND
I SUBAREA NAME '('Al 8.2 UBAREA (AC)
6.28.2I
FLOW TO BUENA 'ASIA LAGOON
I N_7.2 1 9.2
rA7R0.01 / 4440 44.11/A8R 101 43.46 9R 0.01
013 P8
L=2- 0 03 0.040.13
I I P9 / PlO
4 / L=25.7'
- / L=33'-
INLET 7 INLET 8 INLET 9
TG 4440 TG 4411' TG 43.46
IE 42.90' IE 42.60' IE 42.30
Ql0=0.03 CFS Q10=0.03 CFS Q10=0.04 CFS
Q100=0.13 CFS Q100=0.13 CFS Q100=0.13 CFS
FLOW TO BMP 2 TO LAGUNA DRIVE FLOW TO BMP 1 TO LAGUNA DRIVE
013
LjJ KI (NbV 1fr cHI O.¼)wryfl nhIz
cJ73o/2cf 1/28/2020 *
OFCVM1
CORY JONES ENGINEERING
1820 S. EL CAMINO REAL, A205
ENCINI TA 5, CA 92024
(P) 619-884-0576
10 YR PEAK- -100 YR PEAK
FLOW (CFS) FLOW (CFS)
NODE NUMBER 1
ELEVATION 1.0
FLOW DIREC11ON
LONGEST FLOW PATH
PER SUBAREA
PROJECT NUMBER: I FINISH SURFACE SPOT GRADE 419±
CT201 8-0006 I DRAINAGE AREA BOUNDARY
I
I 1
1.1
I
44.89
Ic
— -
=777-
_7Z
1.2
bi 44.2
£-' VFb - -
717 I I_ I
R-6 1--1V jj - .- ---
/1 I I II -;—V-- I
NT-
911 /
- I - - I - - - -
L 2.1
Ilk I 44.89
I r
7
/>> (3) 0.09
I
7
\O5OO/
/ -
/\
V
-
- ----_ /
Wr-
CC N \ N \lee
4-77717 71
-
Ll
cz
/( 4) 0.3
\\\r \\ C//"
\\\\\\\
2.3
7±
MMMMENNEF7 OF moor-
---- N
\ \\\ N
?NN \ N \ \ N N-
\\
DISCHARGE POINT 2 (NORTH)
Q100=1.27 CFS N
V100=1.0 FPS
7H
1
- V dl
-
- -
t Q4
N*Z
N
/
0-03 \&
0.10 0.14,/
145
/ I
X
-
I
- - - - // -- 43.22
1.4
42.81
/-LJ
r- 7 - -
N
- - -- --
- .---- --__j
-
Normal Depth = 0.03 FT N NN EXHIBIT 1 - RATIONAL HYDROLOGY WORKMAP
(EST. AS CHANNEL WITH B 50 z =10, S 66.7%, n 0.1)
D11 HARC
0100=1'12 CFS PRE—CONSTRUCTION PROJECT AREA MAP
CORY JONES ENGINEERING
1820 S. EL CAMINO REAL, A205
ENCINI TA 5, CA 92024
(P) 619-884-0576
k vf6o=z ip IUU LA(,UNA Ut<IV, LJAI<LSUAU,
LEGEND
LEGEND VEL. PER FIG. 3-6 OF SDCH M
SUBAREA NAME Al 8.2 UBAREA (AC)
6.2 8.2
FLOW TO BUENA VISTA LAGOON
10 YR PEAK 100 YR PEAK
FLOW (CFS) FLOW (CFS)
NODE NUMBER 1
ELEVATION 1.0
FLOW DIRECTION
FLOW TO LAGUNA DRIVE 0 10' 2 LONGEST FLOW PATH
I I PER SUBAREA ----
----
1 INCH = 10 FT PROJECT NUMBER:
CT2018-0006 DRAINAGE AREA BOUNDARY
APPENDIX B
RATIONAL HYDROLOGY ANALYSIS
WE H
Page Left Intentionally Blank
WE
RESULTS FROM AES HYDROLOGY PROGRAM
PRE-DEVELOPMENT RATIONAL METHOD RESULTS
DRAINING TO LAGUNA DRIVE CURB AND GUTTER
DRAINAGE AREA NODE FRO NODE TO Area Q10 TC10 1110 Q100 TC100 1100
AC CFS MIN IN/HR CFS MIN IN/HR
1 1.1 1.2 0.03 0.1 3.773 4.216 0.15 3.773 6.587
2 1.2 1.3 0.26 0.64 3.77 4.216 0.85 6.32 5.661
5 1.3 1.41 0.031 0.11 3.81 4.2161 0.141 6.361 5.639
1,2,5 0.83 3.81 4.216 1.12 6.36 5.6
DRAINING TO BUENA VISTA LAGOON
DRAINAGE AREA NODE FRO NODE TO Aea Q10 TC10 110 Q100 TC100 1100
AC CFS MIN IN/HR CFS MIN IN/HR
3 2.1 2.2 0.09 0.25 3.578 4.216 0.4 0.803 6.587
4 2.2 2.31 0.35 0.5 6.66 3.503 0.88 3 6.587
3,4 0.441 0.681 1 1 1.27 3
PRE-DEVELOPMENT
10-YEAR DESIGN STORM
AES CALCULATION REPORTS
WE
Page Left Intentionally Blank
WE
PR10S2 . RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering Software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
*********************** DESCRIPTION OF STUDY
* 10-YR PRE-DEVELOPMENT *
* LAGUNA SUBDIVISION, CARLSBAD, CA *
* AREAS 3 AND 4, DRAINING TO BUENA VISTA LAGOON *
FILE NAME: PR10S2.DAT
TIME/DATE OF STUDY: 16:41 06/03/2020 ----------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ----------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES) = 1.600
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER_DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
FLOW PROCESS FROM NODE 2.00 TO NODE 2.20 IS CODE = 21 ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT = .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 50.00
UPSTREAM ELEVATION(FEET) = 44.89
DOWNSTREAM ELEVATION(FEET) = 43.10
ELEVATION DIFFERENCE(FEET) = 1.79
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.578
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
Page 1
PR1OS2 . RES
NOTE: RAINFALL INTENSITY IS BASED ON IC = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.25
TOTAL AREA(ACRES) = 0.09 TOTAL RUNOFF(CFS) = 0.25
FLOW PROCESS FROM NODE 2.20 TO NODE 2.30 IS CODE = 51 ----------------------------------------------------------------------------
>>>>>COMPUTE TRAPEZOIDAL CHANNEL FLOW<<<<<
>>>>>TRAVELTIME THRU SUBAREA (EXISTING ELEMENT)<<<<<
ELEVATION DATA: UPSTREAM(FEET) = 43.10 DOWNSTREAM(FEET) = 7.00
CHANNEL LENGTH THRU SUBAREA(FEET) = 177.00 CHANNEL SLOPE = 0.2040
CHANNEL BASE(FEET) = 50.00 "Z" FACTOR = 10.000
MANNING'S FACTOR = 0.036 MAXIMUM DEPTH(FEET) = 4.00
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.503
RESIDENTIAL (2. DU/AC OR LESS) RUNOFF COEFFICIENT = .3800
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 68
TRAVEL TIME COMPUTED USING ESTIMATED FLOW(CFS) = 0.50
TRAVEL TIME THRU SUBAREA BASED ON VELOCITY(FEET/SEC.) = 0.96
AVERAGE FLOW DEPTH(FEET) = 0.01 TRAVEL TIME(MIN.) = 3.08
TC(MIN.) = 6.66
SUBAREA AREA(ACRES) = 0.35 SUBAREA RUNOFF(CFS) = 0.47
AREA-AVERAGE RUNOFF COEFFICIENT = 0.439
TOTAL AREA(ACRES) = 0.4 PEAK FLOW RATE(CFS) = 0.68
END OF SUBAREA CHANNEL FLOW HYDRAULICS:
DEPTH(FEET) = 0.01 FLOW VELOCITY(FEET/SEC.) = 1.09
LONGEST FLOWPATH FROM NODE 2.00 TO NODE 2.30 = 227.00 FEET.
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.4 TC(MIN.) = 6.66
PEAK FLOW RATE(CFS) = 0.68
END OF RATIONAL METHOD ANALYSIS
Page 2
PRE10N2 . RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
DESCRIPTION OF STUDY
10-YR PRE-DEVELOPMENT *
LAGUNA SUBDIVISION, CARLSBAD, CA *
AREAS 1, 2, AND 5 - DRAINING TO LAGUNA DRIVE C&G *
FILE NAME: PRE10N2.DAT
TIME/DATE OF STUDY: 17:12 06/03/2020 -------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: -------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES) = 1.600
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER....DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (Fr) (Fr) SIDE / SIDE/ WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (Fr*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
** * * *** * *** * * ** ****** ****** ** **********************************
FLOW PROCESS FROM NODE 1.10 TO NODE 1.20 IS CODE = 21 --------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (43. DU/AC OR LESS) RUNOFF COEFFICIENT = .7700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 91
INITIAL SUBAREA FLOW-LENGTH(FEET) = 50.00
UPSTREAM ELEVATION(FEET) = 44.89
DOWNSTREAM ELEVATION(FEET) = 44.20
ELEVATION DIFFERENCE(FEET) = 0.69
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.773
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
Page 1
PRE10N2 . RES
NOTE: RAINFALL INTENSITY IS BASED ON TC = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.10
TOTAL AREA(ACRES) = 0.03 TOTAL RUNOFF(CFS) = 0.10
FLOW PROCESS FROM NODE 1.20 TO NODE 1.30 IS CODE = 81 ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
NOTE: RAINFALL INTENSITY IS BASED ON TC = 5-MINUTE.
RESIDENTIAL (14.5 DU/AC OR LESS) RUNOFF COEFFICIENT = .5800
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 80
AREA-AVERAGE RUNOFF COEFFICIENT = 0.5997
SUBAREA AREA(ACRES) = 0.26 SUBAREA RUNOFF(CFS) = 0.64
TOTAL AREA(ACRES) = 0.3 TOTAL RUNOFF(CFS) = 0.73
TC(MIN.) = 3.77
FLOW PROCESS FROM NODE 1.30 TO NODE 1.40 IS CODE = 62 ----------------------------------------------------------------------------
>>>>>COMPUTE STREET FLOW TRAVEL TIME THRU SUBAREA<<<<<
>>>>>(STREET TABLE SECTION # 1 USED)<<<<<
UPSTREAM ELEVATION(FEET) = 43.22 DOWNSTREAM ELEVATION(FEET) = 42.81
STREET LENGTH(FEET) = 10.00 CURB HEIGHT(INCHES) = 8.0
STREET HALFWIDTH(FEET) = 30.00
DISTANCE FROM CROWN TO CROSSFALL GRADEBREAK(FEET) = 20.00
INSIDE STREET CROSSFALL(DECIMAL) = 0.018
OUTSIDE STREET CROSSFALL(DECIMAL) = 0.018
SPECIFIED NUMBER OF HALFSTREETS CARRYING RUNOFF = 1
STREET PARKWAY CROSSFALL(DECIMAL) = 0.020
Manning's FRICTION FACTOR for streetfiow section(curb-to-curb) = 0.0150
Manning's FRICTION FACTOR for Back-of-Walk Flow Section = 0.0200
**TRAVEL TIME COMPUTED USING ESTIMATED FLOW(CFS) = 0.78
STREETFLOW MODEL RESULTS USING ESTIMATED FLOW:
STREET FLOW DEPTH(FEET) = 0.20
HALFSTREET FLOOD WIDTH(FEET) = 2.00
AVERAGE FLOW VELOCITY(FEET/SEC.) = 4.40
PRODUCT OF DEPTH&VELOCITY(FT*FT/SEC.) = 0.87
STREET FLOW TRAVEL TIME(MIN.) = 0.04 TC(MIN.) = 3.81
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
GENERAL COMMERCIAL RUNOFF COEFFICIENT = .8000
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 92
AREA-AVERAGE RUNOFF COEFFICIENT = 0.618
SUBAREA AREA(ACRES) = 0.03 SUBAREA RUNOFF(CFS) = 0.10
TOTAL AREA(ACRES) = 0.3 PEAK FLOW RATE(CFS) = 0.83
END OF SUBAREA STREET FLOW HYDRAULICS:
DEPTH(FEET) = 0.20 HALFSTREET FLOOD WIDTH(FEET) = 2.00
FLOW VELOCITY(FEET/SEC.) = 4.40 DEPTH*VELOCITY(FT*FT/SEC.) = 0.87
LONGEST FLOWPATH FROM NODE 1.10 TO NODE 1.40 = 60.00 FEET.
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.3 TC(MIN.) = 3.81
PEAK FLOW RATE(CFS) = 0.83
Page 2
PRE1ON2 . RES
END OF RATIONAL METHOD ANALYSIS
Page 3
WE
Page Left Intentionally Blank I
PRE-DEVELOPMENT
100-YEAR DESIGN STORM
AES CALCULATION REPORTS
WE
Page Left Intentionally Blank
WE
PR100S2 . RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL (c) Copyright 1982-2016 Advanced Engineering Software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY
100-YR PRE-DEVELOPMENT
LAGUNA SUBDIVISION, CARLSBAD, CA
AREAS 3 AND 4 - DRAINING TO BUENA VISTA LAGOON
FILE NAME: PR100S2.DAT
TIME/DATE OF STUDY: 16:53 06/03/2020 ----------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ----------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES) = 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER...DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (Fr) SIDE / SIDE/ WAY (FT) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb) (Depth)*(velocity) Constraint = 1.5 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
FLOW PROCESS FROM NODE 2.10 TO NODE 2.20 IS CODE = 21 ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT = .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 5.00
UPSTREAM ELEVATION(FEET) = 44.89
DOWNSTREAM ELEVATION(FEET) = 43.10
ELEVATION DIFFERENCE(FEET) = 1.79
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 0.803
WARNING: THE MAXIMUM OVERLAND FLOW SLOPE, 10.%, IS USED IN Tc CALCULATION!
Page 1
PR100S2 . RES
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
NOTE: RAINFALL INTENSITY IS BASED ON Ic = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.40
TOTAL AREA(ACRES) = 0.09 TOTAL RUNOFF(CFS) = 0.40
FLOW PROCESS FROM NODE 2.20 TO NODE 2.30 IS CODE = 51 ----------------------------------------------------------------------------
>>>>>COMPUTE TRAPEZOIDAL CHANNEL FLOW<<<<<
>>>>>TRAVELTIME THRU SUBAREA (EXISTING ELEMENT)<<<<<
ELEVATION DATA: UPSTREAM(FEET) = 43.10 DOWNSTREAM(FEET) = 7.00
CHANNEL LENGTH THRU SUBAREA(FEET) = 177.00 CHANNEL SLOPE = 0.2040
CHANNEL BASE(FEET) = 50.00 liz" FACTOR = 10.000
MANNING'S FACTOR = 0.036 MAXIMUM DEPTH(FEET) = 5.00
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
NOTE: RAINFALL INTENSITY IS BASED ON Ic = 5-MINUTE.
RESIDENTIAL (2. DU/AC OR LESS) RUNOFF COEFFICIENT = .3800
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 68
TRAVEL TIME COMPUTED USING ESTIMATED FLOW(CFS) = 0.84
TRAVEL TIME THRU SUBAREA BASED ON VELOCITY(FEET/SEC.) = 1.34
AVERAGE FLOW DEPTH(FEET) = 0.01 TRAVEL TIME(MIN.) = 2.19
Tc(MIN.) = 3.00
SUBAREA AREA(ACRES) = 0.35 SUBAREA RUNOFF(CFS) = 0.88
AREA-AVERAGE RUNOFF COEFFICIENT = 0.439
TOTAL AREA(ACRES) = 0.4 PEAK FLOW RATE(CFS) = 1.27
END OF SUBAREA CHANNEL FLOW HYDRAULICS:
DEPTH(FEET) = 0.02 FLOW VELOCITY(FEET/SEC.) = 1.27
LONGEST FLOWPATH FROM NODE 2.10 TO NODE 2.30 = 182.00 FEET.
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.4 TC(MIN.) = 3.00
PEAK FLOW RATE(CFS) = 1.27
END OF RATIONAL METHOD ANALYSIS
Page 2
PRE100N2 . RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY
100-YR PRE-DEVELOPMENT
LAGUNA SUBDIVISION, CARLSBAD, CA
AREAS 1, 2, AND 5 - DRAINING TO LAGUNA DRIVE C&G
FILE NAME: PRE100N2.DAT
TIME/DATE OF STUDY: 17:18 06/03/2020 ----------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ----------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES) = 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER....DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE! WAY (FT) (FT) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (FT*FT/s)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
FLOW PROCESS FROM NODE 1.10 TO NODE 1.20 IS CODE = 21 ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (43. DU/AC OR LESS) RUNOFF COEFFICIENT = .7700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 91
INITIAL SUBAREA FLOW-LENGTH(FEET) = 50.00
UPSTREAM ELEVATION(FEET) = 44.89
DOWNSTREAM ELEVATION(FEET) = 44.20
ELEVATION DIFFERENCE(FEET) = 0.69
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.773
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
PRE100N2 . RES
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.15
TOTAL AREA(ACRES) = 0.03 TOTAL RUNOFF(CFS) = 0.15
****************************************************************************
FLOW PROCESS FROM NODE 1.20 TO NODE 1.30 IS CODE = 51 ----------------------------------------------------
>>>>>COMPUTE TRAPEZOIDAL CHANNEL FLOW<<<<<
>>>>>TRAVELTIME THRU SUBAREA (EXISTING ELEMENT)<<<<<
ELEVATION DATA: UPSTREAM(FEET) = 44.20 DOWNSTREAM(FEET) = 43.22
CHANNEL LENGTH THRU SUBAREA(FEET) = 131.00 CHANNEL SLOPE = 0.0075
CHANNEL BASE(FEET) = 20.00 "Z" FACTOR = 20.000
MANNING'S FACTOR = 0.015 MAXIMUM DEPTH(FEET) = 5.00
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 5.661
RESIDENTIAL (14.5 DU/AC OR LESS) RUNOFF COEFFICIENT = .5800
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 80
TRAVEL TIME COMPUTED USING ESTIMATED FLOW(CFS) = 0.59
TRAVEL TIME THRU SUBAREA BASED ON VELOCITY(FEET/SEC.) = 0.86
AVERAGE FLOW DEPTH(FEET) = 0.03 TRAVEL TIME(MIN.) = 2.55
Tc(MIN.) = 6.32
SUBAREA AREA(ACRES) = 0.26 SUBAREA RUNOFF(CFS) = 0.85
AREA-AVERAGE RUNOFF COEFFICIENT = 0.600
TOTAL AREA(ACRES) = 0.3 PEAK FLOW RATE(CFS) = 0.98
END OF SUBAREA CHANNEL FLOW HYDRAULICS:
DEPTH(FEET) = 0.04 FLOW VELOCITY(FEET/SEC.) = 1.10
LONGEST FLOWPATH FROM NODE 1.10 TO NODE 1.30 = 181.00 FEET.
FLOW PROCESS FROM NODE 1.30 TO NODE 1.40 IS CODE = 62
>>>>>COMPUTE STREET FLOW TRAVEL TIME THRU SUBAREA<<<<<
>>>>>(5TREET TABLE SECTION # 1 USED)<<<<<
UPSTREAM ELEVATION(FEET) = 43.22 DOWNSTREAM ELEVATION(FEET) = 42.81
STREET LENGTH(FEET) = 10.00 CURB HEIGHT(INCHES) = 8.0
STREET HALFWIDTH(FEET) = 30.00
DISTANCE FROM CROWN TO CROSSFALL GRADEBREAK(FEET) = 20.00
INSIDE STREET CROSSFALL(DECIMAL) = 0.018
OUTSIDE STREET CROSSFALL(DECIMAL) = 0.018
SPECIFIED NUMBER OF HALFSTREETS CARRYING RUNOFF = 2
STREET PARKWAY CROSSFALL(DECIMAL) = 0.020
Manning's FRICTION FACTOR for Streetfiow Section(curb-to-curb) = 0.0150
Manning's FRICTION FACTOR for Back-of-Walk Flow Section = 0.0200
**TRAVEL TIME COMPUTED USING ESTIMATED FLOW(CFS) = 1.05
STREETFLOW MODEL RESULTS USING ESTIMATED FLOW:
STREET FLOW DEPTH(FEET) = 0.20
HALFSTREET FLOOD WIDTH(FEET) = 2.00
AVERAGE FLOW VELOCITY(FEET/SEC.) = 4.40
PRODUCT OF DEPTH&VELOCITY(FT*FT/SEC.) = 0.87
STREET FLOW TRAVEL TIME(MIN.) = 0.04 Tc(MIN.) = 6.36
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 5.639
GENERAL COMMERCIAL RUNOFF COEFFICIENT = .8000
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 92
AREA-AVERAGE RUNOFF COEFFICIENT = 0.618
SUBAREA AREA(ACRES) = 0.03 SUBAREA RUNOFF(CFS) = 0.14
TOTAL AREA(ACRES) = 0.3 PEAK FLOW RATE(CFS) = 1.12
Page 2
PRE100N2 . RES
END OF SUBAREA STREET FLOW HYDRAULICS:
DEPTH(FEET) = 0.20 HALFSTREET FLOOD WIDTH(FEET) = 2.00
FLOW VELOCITY(FEET/SEC.) = 4.40 DEPTH*VELOCITY(FT*FT/SEC.) = 0.87
LONGEST FLOWPATH FROM NODE 1.10 TO NODE 1.40 = 191.00 FEET.
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.3 TC(MIN.) = 6.36
PEAK FLOW RATE(CFS) = 1.12
END OF RATIONAL METHOD ANALYSIS
Page 3
Page Left Intentionally Blank
WE
RESULTS FROM AES HYDROLOGY PROGRAM
POST-DEVELOPMENT RATIONAL METHOD RESULTS
DRAINAGE AREA NODE FROM NODE TO INLET NO. Q10 TC10* 110 Q100 TC100** 1100
CFS MIN IN/HR CFS MIN IN/HR
1,2,3 1 0.49 3.24 4.216 0.77 3.24 6.587
7F,5,8F,9F,10F,11F,12F,13F,13B 2 0.32 3 4.216 0.5 3 6.587
SUM CENTRAL PIPES 0.81 1.27
711 7.11 7.2 7 0.03 2.31 4.216 0.13 2.31 6.587
811 8.11 8.2 8 0.03 3.15 4.216 0.13 3.15 6.587
911 9.11 9.2 9 0.04 3.47 4.216 0.13 3.47 6.587
9B 9.3 9.4 98 0.01 6.28 3.638 0.02 6.28 5.685
SUM NORTH PIPES - 0.11 0.41
1011 2.1 2.2 10 0.02 4.89 4.2161 0.07 4.89 6.587
hR 5.1 5.2 11 0.03 3.89 4.2161 0.13 3.89 6.587
12R 6.1 6.2 12 0.03 3.45 4.2161 0.13 3.45 6.587
13R 6.12 6.3 13R 0.09 5.29 4.0641 0.15 5.29 6.35
13F 6.4 6.42 13F 0.02 1.91 4.216 0.03 1.91 6.587
SUM SOUTH PIPES 0.19 0.51
TOTAL PIPE FLOW 1.11 2.19
20,21,22 C&G 0.11 0.85 4.216 0.17 0.85 6.587
18,19 LAGOON 0.23 7.651 3.251 0.36 7.65 5.007
*NOTE **NOTE
4.216 BASED ON 6.587 BASED ON
5-MINTC 5-MINTC
RESULTS FROM AES HYDROLOGY PROGRAM
Breakdown of additional sub-area drainage area peak flow estimates
POST-DEVELOPMENT RATIONAL METHOD RESULTS
DRAINAGE AREA NODE FROM NODE TO INLET NO. Area Q10 TC10 110 Q100 TC100 1100
acres CFS MIN IN/HR CFS MIN IN/HR
1 1.1 1.2 1 0.03 0.11 3.243 4.216 0.17 3.243 6.587
2 1.2 1.22 1 0.05 0.09 3.24 4.216 0.15 3.24 6.587
3 1.3 1.32 1 0.08 0.29 3.24 4.216 0.46 3.24 6.587
1,2,3 11 0.49 3.24 4.216 0.77 3.24 6.587
DRAINAGE AREA NODE FROM NODE TO INLET NO. Area Q10 TC10 110 Q100 TC100 1100
acres CFS MIN IN/HR CFS MIN IN/HR
7F 7.11 7.1 2 0.01 0.03 3.003 4.216 0.05 3.003 6.587
5 1.22 1.5 2 0.04 0.09 3 4.216 0.13 3 6.587
8F 8.11 8.1 2 0.01 0.03 3 4.216 0.05 3 6.587
9F 9.11 9.1 2 0.01 0.03 3 4.216 0.05 3 6.587
1OF 2.1 2.12 2 0.01 0.04 3 4.216.0.06 3 6.587
hF 5.1 5.12 2 0.01 0.04 3 4.216 0.06 3 6.587
12F 6.1 6.12 2 0.01 0.04 3 4.216 0.06 3 6.587
13F 6.4 6.42 2 0.01 0.02 3 4.216 0.03 3 6.587
13B 5.4 5.42 21 0.011 0.01 3 4.216 0.02 3 6.587
7F,5,8F,9F,1OF,11F 12F,13F,13B 21 1 0.321 3 4.216 0.51 3 6.587
DRAINAGE AREA NODE FROM NODE TO INLET NO. - Area Q10 TC10 110 Q100 TC100 1100
acres CFS MIN IN/HR CFS MIN IN/HR
20 6.5 6.52 C&G 0.01 0.04 0.854 4.216 0.06 0.854 6.587
21 6.61 6.62 C&G 0.01 0.04 0.85 4.216 0.06 0.85 6.587
22 7.3 7.4 C&G 0.01 0.04 0.85 4.216 0.06 0.85 6.587
20,21,22 C&GI 1 0.111 0.851 4.2161 0.171 0.851 6.587
DRAINAGE AREA NODE FROM NODE TO INLET No. Area Q10 TC10 110 Q100 TC100 1100
acres CFS MIN IN/HR CFS MIN IN/HR
18 4.1 4.2 0.01 0.01 7.649 3.205 0.01 7.649 5.007
19 4.2 4.3 0.28 0.22 7.65 3.205 0.35 7.65 5.007
18,19 LAGOON 0.23 7.65 3.25 0.36 7.65 5.007
POST-DEVELOPMENT
10-YEAR DESIGN STORM
AES CALCULATION REPORTS
WE
Page Left Intentionally Blank
WE
POST10I1. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering Software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************* DESCRIPTION OF STUDY
10-YR POST-DEVELOPMENT *
LAGUNA SUBDIVISION, CARLSBAD, CA *
INLET 1 *
** ** * * * * ****************************** *********************
FILE NAME: POST10I1.DAT
TIME/DATE OF STUDY: 14:58 06/04/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ----------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES) = 1.600
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER_DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (Fr) (Fr) SIDE / SIDE/ WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (FT*Fr/5)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
FLOW PROCESS FROM NODE 1.10 TO NODE 1.20 IS CODE = 21 AREA A(1) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
OFFICE PROFESSIONAL/COMMERCIAL RUNOFF COEFFICIENT = .8400
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 94
INITIAL SUBAREA FLOW-LENGTH(FEET) = 58.00
UPSTREAM ELEVATION(FEET) = 46.95
DOWNSTREAM ELEVATION(FEET) = 46.18
ELEVATION DIFFERENCE(FEET) = 0.77
SUBAREA OVERLAND TIME OF FLoW(MIN.) = 3.243
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
Page 1
POST1OI1. RES
NOTE: RAINFALL INTENSITY IS BASED ON TC = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.11
TOTAL AREA(ACRES) = 0.03 TOTAL RUNOFF(CFS) = 0.11
FLOW PROCESS FROM NODE 1.20 TO NODE 1.22 Is CODE = 81 AREA A(2) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
RESIDENTIAL (4.3 DU/AC OR LESS) RUNOFF COEFFICIENT = .4500
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 72
AREA-AVERAGE RUNOFF COEFFICIENT = 0.5962
SUBAREA AREA(ACRES) = 0.05 SUBAREA RUNOFF(CFS) = 0.09
TOTAL AREA(ACRES) = 0.1 TOTAL RUNOFF(CFS) = 0.20
TC(MIN.) = 3.24
****************************************************************************
FLOW PROCESS FROM NODE 1.30 TO NODE 1.32 IS CODE = 81AREAA(3) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
GENERAL INDUSTRIAL RUNOFF COEFFICIENT = .8700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 96
AREA-AVERAGE RUNOFF COEFFICIENT = 0.7331
SUBAREA AREA(ACRES) = 0.08 SUBAREA RUNOFF(CFS) = 0.29
TOTAL AREA(ACRES) = 0.2 TOTAL RUNOFF(CFS) = 0.49
TC(MIN.) = 3.24
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.2 TC(MIN.) = 3.24
PEAK FLOW RATE(CFS) = 0.49
END OF RATIONAL METHOD ANALYSIS
Page 2
POST10I2 . RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering Software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY
10-YR POST-DEVELOPMENT
LAGUNA SUBDIVISION, CARLSBAD, CA
INLET 2
FILE NAME: POST1OI2.DAT
TIME/DATE OF STUDY: 12:22 05/27/2020 ----------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ----------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES) = 1.600
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER....DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (Fr) (FT) SIDE / SIDE! WAY (FT) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (Fr*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
FLOW PROCESS FROM NODE 7.11 TO NODE 7.10 IS CODE = 21 AREA A(7F) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
NEIGHBORHOOD COMMERCIAL RUNOFF COEFFICIENT = .7700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 91
INITIAL SUBAREA FLOW-LENGTH(FEET) = 47.60
UPSTREAM ELEVATION(FEET) = 46.65
DOWNSTREAM ELEVATION(FEET) = 45.44
ELEVATION DIFFERENCE(FEET) = 1.21
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.003
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
Pagel
POST1OI2 . RES
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.03
TOTAL AREA(ACRES) = 0.01 TOTAL RUNOFF(CFS) = 0.03
****************************************************************************
FLOW PROCESS FROM NODE 1.22 TO NODE 1.50 IS CODE = 81 AREA A(5) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
RESIDENTIAL (7.3 DU/AC OR LESS) RUNOFF COEFFICIENT = .5100
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 76
AREA-AVERAGE RUNOFF COEFFICIENT = 0.5620
SUBAREA AREA(ACRES) = 0.04 SUBAREA RUNOFF(CFS) = 0.09
TOTAL AREA(ACRES) = 0.0 TOTAL RUNOFF(CFS) = 0.12
TC(MIN.) = 3.00
FLOW PROCESS FROM NODE 8.11 TO NODE 8.10 Is CODE = 81 AREA A(8F) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
NEIGHBORHOOD COMMERCIAL RUNOFF COEFFICIENT = .7700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 91
AREA-AVERAGE RUNOFF COEFFICIENT = 0.5967
SUBAREA AREA(ACRES) = 0.01 SUBAREA RUNOFF(CFS) = 0.03
TOTAL AREA(ACRES) = 0.1 TOTAL RUNOFF(CFS) = 0.15
TC(MIN.) = 3.00
FLOW PROCESS FROM NODE 9.11 TO NODE 9.10 IS CODE = 81 AREA A(9F) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
NEIGHBORHOOD COMMERCIAL RUNOFF COEFFICIENT = .7700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 91
AREA-AVERAGE RUNOFF COEFFICIENT = 0.6214
SUBAREA AREA(ACRES) = 0.01 SUBAREA RUNOFF(CFS) = 0.03
TOTAL AREA(ACRES) = 0.1 TOTAL RUNOFF(CFS) = 0.18
TC(MIN.) = 3.00
****************************************************************************
FLOW PROCESS FROM NODE 2.10 TO NODE 2.12 IS CODE = 81 AREA A(IOF) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
OFFICE PROFESSIONAL/COMMERCIAL RUNOFF COEFFICIENT = .8400
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 94
AREA-AVERAGE RUNOFF COEFFICIENT = 0.6488
SUBAREA AREA(ACRES) = 0.01 SUBAREA RUNOFF(CFS) = 0.04
TOTAL AREA(ACRES) = 0.1 TOTAL RUNOFF(CFS) = 0.22
TC(MIN.) = 3.00
Page 2
P05T1012 . RES
FLOW PROCESS FROM NODE 6.10 TO NODE 6.12 IS CODE = 81 AREA A(12F) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
OFFICE PROFESSIONAL/COMMERCIAL RUNOFF COEFFICIENT = .8400
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 94
AREA-AVERAGE RUNOFF COEFFICIENT = 0.6700
SUBAREA AREA(ACRES) = 0.01 SUBAREA RUNOFF(CFS) = 0.04
TOTAL AREA(ACRES) = 0.1 TOTAL RUNOFF(CFS) = 0.25
TC(MIN.) = 3.00
* * * * * * * *** * ************************ ********** *
FLOW PROCESS FROM NODE 5.10 TO NODE 5.12 IS CODE = 81 AREA A(IIF) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
OFFICE PROFESSIONAL/COMMERCIAL RUNOFF COEFFICIENT = .8400
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 94
AREA-AVERAGE RUNOFF COEFFICIENT = 0.6870
SUBAREA AREA(ACRES) = 0.01 SUBAREA RUNOFF(CFS) = 0.04
TOTAL AREA(ACRES) = 0.1 TOTAL RUNOFF(CFS) = 0.29
TC(MIN.) = 3.00
****************************************************************************
FLOW PROCESS FROM NODE 6.40 TO NODE 6.42 IS CODE = 81 AREA A(13F) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
NOTE: RAINFALL INTENSITY IS BASED ON IC = 5-MINUTE.
RESIDENTIAL (2. DU/AC OR LESS) RUNOFF COEFFICIENT = .3800
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 68
AREA-AVERAGE RUNOFF COEFFICIENT = 0.6591
SUBAREA AREA(ACRES) = 0.01 SUBAREA RUNOFF(CFS) = 0.02
TOTAL AREA(ACRES) = 0.1 TOTAL RUNOFF(CFS) = 0.31
TC(MIN.) = 3.00
****************************************************************************
FLOW PROCESS FROM NODE 5.40 TO NODE 5.42 IS CODE = 81 AREA A(13B) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
RESIDENTIAL (1. DU/AC OR LESS) RUNOFF COEFFICIENT = .3200
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 65
AREA-AVERAGE RUNOFF COEFFICIENT = 0.6308
SUBAREA AREA(ACRES) = 0.01 SUBAREA RUNOFF(CFS) = 0.01
TOTAL AREA(ACRES) = 0.1 TOTAL RUNOFF(CFS) = 0.32
TC(MIN.) = 3.00
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.1 TC(MIN.) = 3.00
Page 3
P0511012 RES
PEAK FLOW RATE(CFS) = 0.32
END OF RATIONAL METHOD ANALYSIS
Page 4
P0511017. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering Software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************* DESCRIPTION OF STUDY
10-YR POST-DEVELOPMENT
LAGUNA SUBDIVISION, CARLSBAD, CA
INLET 7
FILE NAME: POST10I7.DAT
TIME/DATE OF STUDY: 12:27 05/27/2020 ----------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ----------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES) = 1.600
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER_DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (Fr) (Fr) SIDE / SIDE/ WAY (Fr) (Fr) (Fr) (Fir) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (FT*FT/5)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
FLOW PROCESS FROM NODE 7.11 TO NODE 7.20 IS CODE = 21 AREA A(7R) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT = .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 32.40
UPSTREAM ELEVATION(FEET)= 46.65
DOWNSTREAM ELEVATION(FEET) = 44.40
ELEVATION DIFFERENCE(FEET) = 2.25
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 2.309
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
Page 1
P0511017. RES
NOTE: RAINFALL INTENSITY IS BASED ON IC = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.03
TOTAL AREA(ACRES) = 0.01 TOTAL RUNOFF(CFS) = 0.03
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.0 TC(MIN.) = 2.31
PEAK FLOW RATE(CFS) = 0.03
END OF RATIONAL METHOD ANALYSIS
Page 2
P0511018. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************* DESCRIPTION OF STUDY * 10-YR POST-DEVELOPMENT *
* LAGUNA SUBDIVISION, CARLSBAD, CA *
*INLET8 *
**************************************************************************
FILE NAME: POST10I8.DAT
TIME/DATE OF STUDY: 12:31 05/27/2020 ----------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ----------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES) = 1.600
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER_DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (Fr) SIDE / SIDE! WAY (Fr) (Fr) (Fr) (Fr) (n)
1. 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (Fr*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
FLOW PROCESS FROM NODE 8.11 TO NODE 8.20 IS CODE = 21 AREA A(8R) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT = .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 32.40
UPSTREAM ELEVATION(FEET) = 45.00
DOWNSTREAM ELEVATION(FEET) = 44.11
ELEVATION DIFFERENCE(FEET) = 0.89
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.146
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
Page 1
POST1OI8. RES
NOTE: RAINFALL INTENSITY IS BASED ON IC = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.03
TOTAL AREA(ACRES) = 0.01 TOTAL RUNOFF(CFS) = 0.03
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.0 TC(MIN.) = 3.15
PEAK FLOW RATE(CFS) = 0.03
END OF RATIONAL METHOD ANALYSIS
Page 2
POST10I9. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
********************** DESCRIPTION OF STUDY
10-YR POST-DEVELOPMENT *
LAGUNA SUBDIVISION, CARLSBAD, CA *
INLET 9 *
**************************************************************************
FILE NAME: POST10I9.DAT
TIME/DATE OF STUDY: 12:34 05/27/2020 ----------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ----------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES) = 1.600
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER_DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (Fr) (Fr) SIDE / SIDE/ WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 9.11 TO NODE 9.20 IS CODE = 21 AREA A(9R) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (7.3 DU/AC OR LESS) RUNOFF COEFFICIENT = .5100
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 76
INITIAL SUBAREA FLOW-LENGTH(FEET) = 29.40
UPSTREAM ELEVATION(FEET) = 44.80
DOWNSTREAM ELEVATION(FEET) = 43.46
ELEVATION DIFFERENCE(FEET) = 1.34
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.473
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
Page 1
POST1OI9 . RES
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.04
TOTAL AREA(ACRES) = 0.02 TOTAL RUNOFF(CFS) = 0.04
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.0 TC(MIN.) = 3.47
PEAK FLOW RATE(CFS) = 0.04
END OF RATIONAL METHOD ANALYSIS
Page 2
P051019B. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY
10-YR POST-DEVELOPMENT
LAGUNA SUBDIVISION, CARLSBAD, CA
INLET 9B
FILE NAME: POS10I9B.DAT
TIME/DATE OF STUDY: 12:39 05/27/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ----------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES) = 1.600
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER....DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (Fr) (Fr) SIDE / SIDE/ WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(velocity) Constraint = 1.5 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
FLOW PROCESS FROM NODE 9.30 TO NODE 9.40 IS CODE = 21 AREA A(9B) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (2. DU/AC OR LESS) RUNOFF COEFFICIENT = .3800
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 68
INITIAL SUBAREA FLOW-LENGTH(FEET) = 23.30
UPSTREAM ELEVATION(FEET) = 43.33
DOWNSTREAM ELEVATION(FEET) = 43.10
ELEVATION DIFFERENCE(FEET) = 0.23
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 6.283
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.638
Page 1
POS1OI9B. RES
SUBAREA RUNOFF(CFS) = 0.01
TOTAL AREA(ACRES) = 0.01 TOTAL RUNOFF(CFS) = 0.01
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.0 TC(MIN.) = 6.28
PEAK FLOW RATE(CFS) = 0.01
END OF RATIONAL METHOD ANALYSIS
/
Page 2
PO10I10R. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering Software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************ DESCRIPTION OF STUDY
10-YR POST-DEVELOPMENT *
LAGUNA SUBDIVISION, CARLSBAD, CA *
INLET 10 *
**************************************************************************
FILE NAME: PO10I10R.DAT
TIME/DATE OF STUDY: 12:44 05/27/2020 ------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES) = 1.600
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER_DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (Fr) SIDE / SIDE/ WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb) (Depth)*(velocity) Constraint = 1.5 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 2.10 TO NODE 2.20 IS CODE = 21 AREA A(IOR) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (10.9 DU/AC OR LESS) RUNOFF COEFFICIENT = .5400
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 78
INITIAL SUBAREA FLOW-LENGTH(FEET) = 50.00
UPSTREAM ELEVATION(FEET) = 46.50
DOWNSTREAM ELEVATION(FEET) = 44.95
ELEVATION DIFFERENCE(FEET) = 1.55
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 4.888
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
Page 1
PO10I10R. RES
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.02
TOTAL AREA(ACRES) = 0.01 TOTAL RUNOFF(CFS) = 0.02 ------------
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.0 TC(MIN.) = 4.89
PEAK FLOW RATE(CFS) = 0.02
END OF RATIONAL METHOD ANALYSIS
Page 2
P010111. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering Software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY
10-YR POST-DEVELOPMENT *
LAGUNA SUBDIVISION, CARLSBAD, CA *
INLET 11 *
FILE NAME: P010I11.DAT
TIME/DATE OF STUDY: 12:49 05/27/2020 ----------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: --------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES) = 1.600
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER_DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (Fr) SIDE / SIDE/ WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
FLOW PROCESS FROM NODE 5.10 TO NODE 5.20 IS CODE = 21 AREA A(IIR)
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT = .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 40.00
UPSTREAM ELEVATION(FEET) = 46.30
DOWNSTREAM ELEVATION(FEET) = 45.50
ELEVATION DIFFERENCE(FEET) = 0.80
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.885
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
Pagel
PO10I11.RES
NOTE: RAINFALL INTENSITY IS BASED ON Ic = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.03
TOTAL AREA(ACRES) = 0.01 TOTAL RUNOFF(CFS) = 0.03
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.0 TC(MIN.) = 3.89
PEAK FLOW RATE(CFS) = 0.03
END OF RATIONAL METHOD ANALYSIS
Page 2
P010112 . RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY * 10-YR POST-DEVELOPMENT * LAGUNA SUBDIVISION, CARLSBAD, CA * INLET 12 **************************************************************************
FILE NAME: P010112.DAT
TIME/DATE OF STUDY: 12:51 05/27/2020 ----------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES) = 1.600
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER_DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODE.L*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (Fr) SIDE / SIDE! WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(velocity) Constraint = 1.5 (FT*Fr/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
FLOW PROCESS FROM NODE 6.10 TO NODE 6.20 IS CODE = 21 AREA A(12R)
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT = .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 40.00
UPSTREAM ELEVATION(FEET) = 46.10
DOWNSTREAM ELEVATION(FEET) = 44.96
ELEVATION DIFFERENCE(FEET) = 1.14
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.453
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
Page 1
P010112. RES
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.03
TOTAL AREA(ACRES) = 0.01 TOTAL RUNOFF(CFS) = 0.03
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.0 TC(MIN.) = 3.45
PEAK FLOW RATE(CFS) = 0.03
END OF RATIONAL METHOD ANALYSIS
Page 2
P010113 F. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
DESCRIPTION OF STUDY
* 10-YR POST-DEVELOPMENT
* LAGUNA SUBDIVISION, CARLSBAD, CA
* INLET 13F
FILE NAME: PO10I13F.DAT
TIME/DATE OF STUDY: 13:02 05/27/2020 ----------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ----------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES) = 1.600
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER....DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE! WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb) (Depth)*(Velocity) Constraint = 1.5 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
FLOW PROCESS FROM NODE 6.40 TO NODE 6.42 IS CODE = 21 ------------------------------------------------------------------------ AREA A(13F)
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (2.9 DU/AC OR LESS) RUNOFF COEFFICIENT = .4100
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 70
INITIAL SUBAREA FLOW-LENGTH(FEET) = 10.60
UPSTREAM ELEVATION(FEET) = 44.47
DOWNSTREAM ELEVATION(FEET) = 43.46
ELEVATION DIFFERENCE(FEET) = 1.01
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 1.908
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
Page 1
P010113 F. RES
NOTE: RAINFALL INTENSITY IS BASED ON IC = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.02
TOTAL AREA(ACRES) = 0.01 TOTAL RUNOFF(CFS) = 0.02
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.0 TC(MIN.) = 1.91
PEAK FLOW RATE(CFS) = 0.02
END OF RATIONAL METHOD ANALYSIS
Page 2
P010113 B. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering Software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY
* 10-YR POST-DEVELOPMENT *
* LAGUNA SUBDIVISION, CARLSBAD, CA *
* INLET 13R *
**************************************************************************
FILE NAME: PO10I13B.DAT
TIME/DATE OF STUDY: 12:56 05/27/2020 ----------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ----------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES) = 1.600
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER....DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (Fr) (Fr) SIDE I SIDE! WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (FT*Fr/5)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 6.12 TO NODE 6.30 IS CODE = 21 AREA A(13R) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (43. DU/AC OR LESS) RUNOFF COEFFICIENT = .7700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 91
INITIAL SUBAREA FLOW-LENGTH(FEET) = 77.00
UPSTREAM ELEVATION(FEET) = 44.80
DOWNSTREAM ELEVATION(FEET) = 44.75
ELEVATION DIFFERENCE(FEET) = 0.05
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 5.292
WARNING: INITIAL SUBAREA FLOW PATH LENGTH IS GREATER THAN
Page 1
P010113 B. RES
THE MAXIMUM OVERLAND FLOW LENGTH = 50.00
(Reference: Table 3-1B of Hydrology Manual)
THE MAXIMUM OVERLAND FLOW LENGTH IS USED IN IC CALCULATION!
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.064
SUBAREA RUNOFF(CFS) = 0.09
TOTAL AREA(ACRES) = 0.03 TOTAL RUNOFF(CFS) = 0.09
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.0 TC(MIN.) = 5.29'
PEAK FLOW RATE(CFS) = 0.09
END OF RATIONAL METHOD ANALYSIS
Page 2
PO10CNG. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************* DESCRIPTION OF STUDY
* 10-YR POST-DEVELOPMENT * LAGUNA SUBDIVISION, CARLSBAD, CA * AREAS 20, 21, AND 22 - PARKWAY FLOW TO CURB AND GUTTER **************************************************************************
FILE NAME: PO10CNG.DAT
TIME/DATE OF STUDY: 15:09 05/27/2020 ----------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ----------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES) = 1.600
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER_DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (Fr) SIDE / SIDE/ WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
FLOW PROCESS FROM NODE 6.50 TO NODE 6.52 IS CODE = 21 ---------------------------------------------------------------------------- AREA A(20)
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
GENERAL INDUSTRIAL RUNOFF COEFFICIENT = .8700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 96
INITIAL SUBAREA FLOW-LENGTH(FEET) = 10.00
UPSTREAM ELEVATION(FEET) = 45.00
DOWNSTREAM ELEVATION(FEET) = 44.64
ELEVATION DIFFERENCE(FEET) = 0.36
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 0.854
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
Page 1
PO10CNG.RES
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.04
TOTAL AREA(ACRES) = 0.01 TOTAL RUNOFF(CFS) = 0.04
FLOW PROCESS FROM NODE 6.61 TO NODE 6.62 IS CODE = 81 AREA A(21)
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
NOTE: RAINFALL INTENSITY IS BASED ON IC = 5-MINUTE.
GENERAL INDUSTRIAL RUNOFF COEFFICIENT = .8700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 96
AREA-AVERAGE RUNOFF COEFFICIENT = 0.8700
SUBAREA AREA(ACRES) = 0.01 SUBAREA RUNOFF(CFS) = 0.04
TOTAL AREA(ACRES) = 0.0 TOTAL RUNOFF(CFS) = 0.07
TC(MIN.) = 0.85
FLOW PROCESS FROM NODE 7.3 TO NODE 7.4 IS CODE = 81 AREA A(22) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.216
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
GENERAL INDUSTRIAL RUNOFF COEFFICIENT = .8700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 96
AREA-AVERAGE RUNOFF COEFFICIENT = 0.8700
SUBAREA AREA(ACRES) = 0.01 SUBAREA RUNOFF(CFS) = 0.04
TOTAL AREA(ACRES) = 0.0 TOTAL RUNOFF(CFS) = 0.11
TC(MIN.) = 0.85
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.0 TC(MIN.) = 0.85
PEAK FLOW RATE(CFS) = 0.11
END OF RATIONAL METHOD ANALYSIS
Page 2
P010LAG. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering Software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
********************** DESCRIPTION OF STUDY
10-YR POST-DEVELOPMENT *
LAGUNA SUBDIVISION, CARLSBAD, CA *
AREAS 18 AND 19, DRAINS TO BUENA VISTA LAGOON *
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * * * * * * * *
FILE NAME: P010LAG.DAT
TIME/DATE OF STUDY: 15:15 05/27/2020 -------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: -------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 10.00
6-HOUR DURATION PRECIPITATION (INCHES) = 1.600
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER....DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) constraint = 1.5 (Fr*Fr/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
FLOW PROCESS FROM NODE 4.10 TO NODE 4.20 IS CODE = 21 AREA A(18) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
NATURAL DESERT LANDSCAPING RUNOFF COEFFICIENT = .2500
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 77
INITIAL SUBAREA FLOW-LENGTH(FEET) = 40.00
UPSTREAM ELEVATION(FEET) = 46.31
DOWNSTREAM ELEVATION(FEET) = 45.50
ELEVATION DIFFERENCE(FEET) = 0.81
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 7.649
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.205
Page 1
POlO LAG. RES
SUBAREA RUNOFF(CFS) = 0.01
TOTAL AREA(ACRES) = 0.01 TOTAL RUNOFF(CFS) = 0.01
FLOW PROCESS FROM NODE 4.2 TO NODE 4.3 IS CODE = 81 AREA A(19) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
10 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.205
NATURAL DESERT LANDSCAPING RUNOFF COEFFICIENT = .2500
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 77
AREA-AVERAGE RUNOFF COEFFICIENT = 0.2500
SUBAREA AREA(ACRES) = 0.28 SUBAREA RUNOFF(CFS) = 0.22
TOTAL AREA(ACRES) = 0.3 TOTAL RUNOFF(CFS) = 0.23
TC(MIN.) = 7.65
END OF STUDY-SUMMARY:
TOTAL AREA(ACRES) = 0.3 TC(MIN.) = 7.65
PEAK FLOW RATE(CFS) = 0.23
END OF RATIONAL METHOD ANALYSIS
Page 2
POST-DEVELOPMENT
100-YEAR DESIGN STORM
AES CALCULATION REPORTS
WE
Page Left Intentionally Blank
WE
10011PO. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************ DESCRIPTION OF STUDY * 100-YR POST-DEVELOPMENT *
* LACUNA SUBDIVISION, CARLSBAD, CA *
*INLET1 *
**************************************************************************
FILE NAME: 100I1PO.DAT
TIME/DATE OF STUDY: 15:28 06/04/2020 ----------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES) = 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER_DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (Fr) (Fr) SIDE / SIDE/ WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 1.10 TO NODE 1.20 IS CODE = 21 AREA A(1) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
OFFICE PROFESSIONAL/COMMERCIAL RUNOFF COEFFICIENT = .8400
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 94
INITIAL SUBAREA FLOW-LENGTH(FEET) = 58.00
UPSTREAM ELEVATION(FEET) = 46.95
DOWNSTREAM ELEVATION(FEET) = 46.18
ELEVATION DIFFERENCE(FEET) = 0.77
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.243
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
10011PO. RES
NOTE: RAINFALL INTENSITY IS BASED ON IC = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.17
TOTAL AREA(ACRES) = 0.03 TOTAL RUNOFF(CFS) = 0.17
****************************************************************************
FLOW PROCESS FROM NODE 1.20 TO NODE 1.22 IS CODE = 81 AREA A(2) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
RESIDENTIAL (4.3 DU/AC OR LESS) RUNOFF COEFFICIENT = .4500
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 72
AREA-AVERAGE RUNOFF COEFFICIENT = 0.5962
SUBAREA AREA(ACRES) = 0.05 SUBAREA RUNOFF(CFS) = 0.15
TOTAL AREA(ACRES) = 0.1 TOTAL RUNOFF(CFS) = 0.31
TC(MIN.) = 3.24
FLOW PROCESS FROM NODE 1.30 TO NODE 1.32 IS CODE = 81 AREA A(3) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
NOTE: RAINFALL INTENSITY IS BASED ON IC = 5-MINUTE.
GENERAL INDUSTRIAL RUNOFF COEFFICIENT = .8700 4
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 96
AREA-AVERAGE RUNOFF COEFFICIENT = 0.7331
SUBAREA AREA(ACRES) = 0.08 SUBAREA RUNOFF(CFS) = 0.46
TOTAL AREA(ACRES) = 0.2 TOTAL RUNOFF(CFS) = 0.77
TC(MIN.) = 3.24
END OF STUDY SUMMARY:
--.-------
H
TOTAL AREA(ACRES) = 0.2 TC(MIN.) = 3.24
PEAK FLOW RATE(CFS) = 0.77
END OF RATIONAL METHOD ANALYSIS
Page 2
10012 P0. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) copyright 1982-2016 Advanced Engineering Software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY
100-YR POST-DEVELOPMENT
LAGUNA SUBDIVISION, CARLSBAD, CA
INLET 2
FILE NAME: 100I2PO.DAT
TIME/DATE OF STUDY: 09:54 05/28/2020
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ----------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES) = 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C'-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER....DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (Fr) (Fr) SIDE / SIDE/ WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (Fr*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
** * * * * * * * * ****** * * *
FLOW PROCESS FROM NODE 7.11 TO NODE 7.10 IS CODE = 21 AREA A(7F) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
NEIGHBORHOOD COMMERCIAL RUNOFF COEFFICIENT = .7700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 91
INITIAL SUBAREA FLOW-LENGTH(FEET) = 47.60
UPSTREAM ELEVATION(FEET)= 46.65
DOWNSTREAM ELEVATION(FEET) = 45.44
ELEVATION DIFFERENCE(FEET) = 1.21
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.003
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
10012 P0. RES
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.05
TOTAL AREA(ACRES) = 0.01 TOTAL RUNOFF(CFS) = 0.05
FLOW PROCESS FROM NODE 1.22 TO NODE 1.50 IS CODE = 81 AREA A(5)
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
NOTE: RAINFALL INTENSITY IS BASED ON Ic = 5-MINUTE.
RESIDENTIAL (7.3 DU/AC OR LESS) RUNOFF COEFFICIENT = .5100
SOIL CLASSIFICATION IS t1 B"
S.C.S. CURVE NUMBER (AMC II) = 76
AREA-AVERAGE RUNOFF COEFFICIENT = 0.5620
SUBAREA AREA(ACRES) = 0.04 SUBAREA RUNOFF(CFS) = 0.13
TOTAL AREA(ACRES) = 0.0 TOTAL RUNOFF(CFS) = 0.19
TC(MIN.) = 3.00
FLOW PROCESS FROM NODE 8.11 TO NODE 8.10 IS CODE = 81 AREA A(8F) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
NEIGHBORHOOD COMMERCIAL RUNOFF COEFFICIENT = .7700
SOIL CLASSIFICATION IS t1B"
S.C.S. CURVE NUMBER (AMC II) = 91
AREA-AVERAGE RUNOFF COEFFICIENT = 0.5967
SUBAREA AREA(ACRES) = 0.01 SUBAREA RUNOFF(CFS) = 0.05
TOTAL AREA(ACRES) = 0.1 TOTAL RUNOFF(CFS) = 0.24
TC(MIN.) = 3.00
FLOW PROCESS FROM NODE 9.11 TO NODE --. 10 IS CODE ---1 AREA A(9F)----------------------------------------------------------------------------i >>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
NOTE: RAINFALL INTENSITY IS BASED ON Ic = 5-MINUTE.
NEIGHBORHOOD COMMERCIAL RUNOFF COEFFICIENT = .7700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 91
AREA-AVERAGE RUNOFF COEFFICIENT = 0.6214
SUBAREA AREA(ACRES) = 0.01 SUBAREA RUNOFF(CFS) = 0.05
TOTAL AREA(ACRES) = 0.1 TOTAL RUNOFF(CFS) = 0.29
TC(MIN.) = 3.00
****************************************************************************
FLOW PROCESS FROM NODE 2.10 TO NODE 2.12 IS CODE = 81 AREA A(IOF) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
NOTE: RAINFALL INTENSITY IS BASED ON IC = 5-MINUTE.
OFFICE PROFESSIONAL/COMMERCIAL RUNOFF COEFFICIENT = .8400
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 94
AREA-AVERAGE RUNOFF COEFFICIENT = 0.6488
SUBAREA AREA(ACRES) = 0.01 SUBAREA RUNOFF(CFS) = 0.06
TOTAL AREA(ACRES) = 0.1 TOTAL RUNOFF(CFS) = 0.34
TC(MIN.) = 3.00
Page 2
10012 P0. RES
FLOW PROCESS FROM NODE 6.10 TO NODE 6.12 IS CODE = 81AREAA(12F) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
OFFICE PROFESSIONAL/COMMERCIAL RUNOFF COEFFICIENT = .8400
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 94
AREA-AVERAGE RUNOFF COEFFICIENT = 0.6700
SUBAREA AREA(ACRES) = 0.01 SUBAREA RUNOFF(CFS) = 0.06
TOTAL AREA(ACRES) = 0.1 TOTAL RUNOFF(CFS) = 0.40
TC(MIN.) = 3.00
FLOW PROCESS FROM NODE 5.10 TO NODE 5.12 IS CODE = 81 AREA A(11F) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
OFFICE PROFESSIONAL/COMMERCIAL RUNOFF COEFFICIENT = .8400
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 94
AREA-AVERAGE RUNOFF COEFFICIENT = 0.6870
SUBAREA AREA(ACRES) = 0.01 SUBAREA RUNOFF(CFS) = 0.06
TOTAL AREA(ACRES) = 0.1 TOTAL RUNOFF(CFS) = 0.45
TC(MIN.) = 3.00
****************************************************************************
FLOW PROCESS FROM NODE 6.40 TO NODE 6.42 IS CODE = 81 AREA A(13F)
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
100 YEAR RAINFALL INTENSITY(INCH/HOUR) 6.587
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
RESIDENTIAL (2. DU/AC OR LESS) RUNOFF COEFFICIENT = .3800
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 68
AREA-AVERAGE RUNOFF COEFFICIENT = 0.6591
SUBAREA AREA(ACRES) = 0.01 SUBAREA RUNOFF(CFS) = 0.03
TOTAL AREA(ACRES) = 0.1 TOTAL RUNOFF(CFS) = 0.48
TC(MIN.) = 3.00
****************************************************************************
FLOW PROCESS FROM NODE 5.40 TO NODE 5.42 IS CODE = 81 AREA A(13B) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
RESIDENTIAL (1. DU/AC OR LESS) RUNOFF COEFFICIENT = .3200
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 65
AREA-AVERAGE RUNOFF COEFFICIENT = 0.6308
SUBAREA AREA(ACRES) = 0.01 SUBAREA RUNOFF(CFS) = 0.02
TOTAL AREA(ACRES) = 0.1 TOTAL RUNOFF(CFS) = 0.50
TC(MIN.) = 3.00
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.1 TC(MIN.) = 3.00
Page 3
10012P0. RES
PEAK FLOW RATE(CFS) = 0.50
END OF RATIONAL METHOD ANALYSIS
Page 4
10017 P0. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering Software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY
100-YR POST-DEVELOPMENT
LAGUNA SUBDIVISION, CARLSBAD, CA
INLET 7
FILE NAME: 100I7P0.DAT
TIME/DATE OF STUDY: 09:57 05/28/2020 ----------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ----------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES) = 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF-GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER...DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (Fr) (Fr) SIDE / SIDE! WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (Fr*Fr/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
FLOW PROCESS FROM NODE 7.11 TO NODE 7.20 IS CODE = 21 AREA A(7R) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALVSIS<<<<<
RESIDENTIAL (24.*DU/AC OR LESS) RUNOFF COEFFICIENT = .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 32.40
UPSTREAM ELEVATION(FEET) = 46.65
DOWNSTREAM ELEVATION(FEET) = 44.40
ELEVATION DIFFERENCE(FEET) = 2.25
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 2.309
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
10017P0. RES
NOTE: RAINFALL INTENSITY IS BASED ON IC = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.13
TOTAL AREA(ACRES) = 0.03 TOTAL RUNOFF(CFS) = 0.13
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.0 TC(MIN.) = 2.31
PEAK FLOW RATE(CFS) = 0.13 ------------------
END OF RATIONAL METHOD ANALYSIS
Page 2
10018P0. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering Software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
DESCRIPTION OF STUDY
100-YR POST-DEVELOPMENT *
LAGUNA SUBDIVISION, CARLSBAD, CA *
INLET 8 *
FILE NAME: 100I8PO.DAT
TIME/DATE OF STUDY: 09:59 05/28/2020 --------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: --------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES) = 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C'-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER_DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (Fr) SIDE / SIDE/ WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (Fr*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
FLOW PROCESS FROM NODE 8.11 TO NODE 8.20 IS CODE = 21 AREA A(8R) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT = .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 32.40
UPSTREAM ELEVATION(FEET) = 45.00
DOWNSTREAM ELEVATION(FEET) = 44.11
ELEVATION DIFFERENCE(FEET) = 0.89
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.146
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
100I8Po. RES
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.13
TOTAL AREA(ACRES) = 0.03 TOTAL RUNOFF(CFS) = 0.13
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.0 TC(MIN.) = 3.15
PEAK FLOW RATE(CFS) = 0.13
END OF RATIONAL METHOD ANALYSIS
Page 2
10019Po. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering Software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************* DESCRIPTION OF STUDY
100-YR POST-DEVELOPMENT *
LAGUNA SUBDIVISION, CARLSBAD, CA *
INLET 9 *
FILE NAME: 100I9PO.DAT
TIME/DATE OF STUDY: 10:01 05/28/2020 ----------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
- -- 2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES) = 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER_DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE! WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0;167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(velocity) Constraint = 1.5 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 9.11 TO NODE 9.20 IS CODE = 21 AREA A(9R) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (7.3 DU/AC OR LESS) RUNOFF COEFFICIENT = .5100
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 76
INITIAL SUBAREA FLOW-LENGTH(FEET) = 29.40
UPSTREAM ELEVATION(FEET) = 44.80
DOWNSTREAM ELEVATION(FEET) = 43.46
ELEVATION DIFFERENCE(FEET) = 1.34
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.473
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
10019P0. RES
NOTE: RAINFALL INTENSITY IS BASED ON IC = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.13
TOTAL AREA(ACRES) = 0.04 TOTAL RUNOFF(CFS) = 0.13
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.0 TC(MIN.) = 3.47
PEAK FLOW RATE(CFS) = 0.13
END OF RATIONAL METHOD ANALYSIS
Page 2
100I9BPO. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(C) Copyright 1982-2016 Advanced Engineering Software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************* DESCRIPTION OF STUDY * 100-YR POST-DEVELOPMENT * LAGUNA SUBDIVISION, CARLSBAD, CA * INLET 9B
FILE NAME: 100I9BPO.DAT
TIME/DATE OF STUDY: 10:03 05/28/2020 --------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: --------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES) = 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER_DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (Fr) SIDE / SIDE! WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
FLOW PROCESS FROM NODE 9.30 TO NODE 9.40 IS CODE = 21 AREA A(9B) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (2. DU/AC OR LESS) RUNOFF COEFFICIENT = .3800
SOIL CLASSIFICATION IS "Bt'
S.C.S. CURVE NUMBER (AMC II) = 68
INITIAL SUBAREA FLOW-LENGTH(FEET) = 23.30
UPSTREAM ELEVATION(FEET) = 43.33
DOWNSTREAM ELEVATION(FEET) = 43.10
ELEVATION DIFFERENCE(FEET) = 0.23
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 6.283
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 5.685
Page 1
100I9BPO.RES
SUBAREA RUNOFF(CFS) = 0.02
TOTAL AREA(ACRES) = 0.01 TOTAL RUNOFF(CFS) = 0.02
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.0 TC(MIN.) = 6.28
PEAK FLOW RATE(CFS) = 0.02
END OF RATIONAL METHOD ANALYSIS
Page 2
lOOIlORP. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering Software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************ DESCRIPTION OF STUDY * 100-YR POST-DEVELOPMENT * LAGUNA SUBDIVISION, CARLSBAD, CA * INLET 10
FILE NAME: 100I10RP.DAT
TIME/DATE OF STUDY: 10:07 05/28/2020 ----------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ----------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES) = 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER....DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (Fr) SIDE / SIDE! WAY (FT) (Fr) (Fr) (Fr) (n)
-
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 2.10 TO NODE 2.20 IS CODE = 21AREAA(I0R) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (10.9 DU/AC OR LESS) RUNOFF COEFFICIENT = .5400
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 78
INITIAL SUBAREA FLOW-LENGTH(FEET) = 50.00
UPSTREAM ELEVATION(FEET) = 46.50
DOWNSTREAM ELEVATION(FEET) = 44.95
ELEVATION DIFFERENCE(FEET) = 1.55
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 4.888
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
100I1ORP. RES
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.07
TOTAL AREA(ACRES) = 0.02 TOTAL RUNOFF(CFS) = 0.07
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.0 Tc(MIN.) = 4.89
PEAK FLOW RATE(CFS) = 0.07
END OF RATIONAL METHOD ANALYSIS
Page 2
100I11PO. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************* DESCRIPTION OF STUDY * 100-YR POST-DEVELOPMENT *
* LAGUNA SUBDIVISION, CARLSBAD, CA *
* INLET 11 *
**************************************************************************
FILE NAME: 100I11PO.DAT
TIME/DATE OF STUDY: 10:10 05/28/2020 ----------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ----------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES) = 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER_DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE/ WAY (Fr) (Fr) (Fr) (Fir) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (FT*Fr/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 5.10 TO NODE 5.20 IS CODE = 21AREAA(IIR)
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT = .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 40.00
UPSTREAM ELEVATION(FEET) = 46.30
DOWNSTREAM ELEVATION(FEET) = 45.50
ELEVATION DIFFERENCE(FEET) = 0.80
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.885
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Pagel
100I11PO. RES
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.13
TOTAL AREA(ACRES) = 0.03 TOTAL RUNOFF(CFS) = 0.13
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.0 Tc(MIN.) = 3.89
PEAK FLOW RATE(CFS) = 0.13
END OF RATIONAL METHOD ANALYSIS
Page 2
100i12Po. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering Software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
DESCRIPTION OF STUDY * 100-YR POST-DEVELOPMENT * LAGUNA SUBDIVISION, CARLSBAD, CA * INLET 12
FILE NAME: 100112P0.DAT
TIME/DATE OF STUDY: 10:12 05/28/2020 --------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES) = 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER_DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (Fr) (Fr) SIDE / SIDE! WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 6.10 TO NODE 6.20 IS CODE = 21 AREA A(1 2R) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (24. DU/AC OR LESS) RUNOFF COEFFICIENT = .6700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 85
INITIAL SUBAREA FLOW-LENGTH(FEET) = 40.00
UPSTREAM ELEVATION(FEET) = 46.10
DOWNSTREAM ELEVATION(FEET) = 44.96
ELEVATION DIFFERENCE(FEET) = 1.14
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 3.453
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
100112 P0. RES
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.13
TOTAL AREA(ACRES) = 0.03 TOTAL RUNOFF(CFS) = 0.13
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.0 Tc(MIN.) = 3.45
PEAK FLOW RATE(CFS) = 0.13
END OF RATIONAL METHOD ANALYSIS
Page 2
100I13BP. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY
100-YR POST-DEVELOPMENT *
LAGUNA SUBDIVISION, CARLSBAD, CA *
INLET 13R *
**************************************************************************
FILE NAME: 100I13BP.DAT
TIME/DATE OF STUDY: 10:16 05/28/2020 -------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: -------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES) = 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER_DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (Fr) (Fr) SIDE / SIDE/ WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (Fr*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
****************************************************************************
FLOW PROCESS FROM NODE 6.12 TO NODE 6.30 IS CODE = 21 AREA A(13R) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (43. DU/AC OR LESS) RUNOFF COEFFICIENT = .7700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 91
INITIAL SUBAREA FLOW-LENGTH(FEET) = 77.00
UPSTREAM ELEVATION(FEET) = 44.80
DOWNSTREAM ELEVATION(FEET) = 44.75
ELEVATION DIFFERENCE(FEET) = 0.05
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 5.292
WARNING: INITIAL SUBAREA FLOW PATH LENGTH IS GREATER THAN
Page 1
100I13BP.RES
THE MAXIMUM OVERLAND FLOW LENGTH = 50.00
(Reference: Table 3-1B of Hydrology Manual)
THE MAXIMUM OVERLAND FLOW LENGTH IS USED IN Tc CALCULATION!
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.350
SUBAREA RUNOFF(CFS) = 0.15
TOTAL AREA(ACRES) = 0.03 TOTAL RUNOFF(CFS) = 0.15
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.0 TC(MIN.) = 5.29
PEAK FLOW RATE(CFS) = 0.15
END OF RATIONAL METHOD ANALYSIS
Page 2
100I13FP. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering Software (aes)
Ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY * 100-YR POST-DEVELOPMENT * LAGUNA SUBDIVISION, CARLSBAD, CA * INLET 13F
FILE NAME: 100I13FP.DAT
TIME/DATE OF STUDY: 10:19 05/28/2020 ----------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ----------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES) = 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER....DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (Fr) SIDE / SIDE/ WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (Fr*Fr/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
FLOW PROCESS FROM NODE 6.40 TO NODE 6.42 IS CODE = 21 AREA A(13F) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
RESIDENTIAL (2.9 DU/AC OR LESS) RUNOFF COEFFICIENT = .4100
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 70
INITIAL SUBAREA FLOW-LENGTH(FEET) = 10.60
UPSTREAM ELEVATION(FEET) = 44.47
DOWNSTREAM ELEVATION(FEET) = 43.46
ELEVATION DIFFERENCE(FEET) = 1.01
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 1.908
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
100I13FP. RES
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.03
TOTAL AREA(ACRES) = 0.01 TOTAL RUNOFF(CFS) = 0.03
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.0 Tc(MIN.) = 1.91
PEAK FLOW RATE(CFS) = 0.03
END OF RATIONAL METHOD ANALYSIS
Page 2
100CNGPO. RES
* * * **** * ************************* ** ******* ********* ****
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************** DESCRIPTION OF STUDY * 100-YR POST-DEVELOPMENT * LAGUNA SUBDIVISION, CARLSBAD, CA * AREAS 20, 21, AND 22 - PARKWAY FLOW TO CURB AND GUTTER
FILE NAME: 100CNGPO.DAT
TIME/DATE OF STUDY: 10:23 05/28/2020 ----------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ----------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES) = 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER....DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (Fr) (Fr) SIDE / SIDE! WAY, (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312 0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (FT*FT!S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
FLOW PROCESS FROM NODE 6.50 TO NODE 6.52 IS CODE = 21AREAA(20) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
GENERAL INDUSTRIAL RUNOFF COEFFICIENT = .8700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 96
INITIAL SUBAREA FLOW-LENGTH(FEET) = 10.00
UPSTREAM ELEVATION(FEET) = 45.00
DOWNSTREAM ELEVATION(FEET) = 44.64
ELEVATION DIFFERENCE(FEET) = 0.36
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 0.854
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
Page 1
100CNGPO. RES
NOTE: RAINFALL INTENSITY IS BASED ON Ic = 5-MINUTE.
SUBAREA RUNOFF(CFS) = 0.06
TOTAL AREA(ACRES) = 0.01 TOTAL RUNOFF(CFS) = 0.06
FLOW PROCESS FROM NODE 6.61 TO NODE 6.62 IS CODE = 81 AREA A(21)
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
NOTE: RAINFALL INTENSITY IS BASED ON Ic = 5-MINUTE.
GENERAL INDUSTRIAL RUNOFF COEFFICIENT = .8700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 96
AREA-AVERAGE RUNOFF COEFFICIENT = 0.8700
SUBAREA AREA(ACRES) = 0.01 SUBAREA RUNOFF(CFS) = 0.06
TOTAL AREA(ACRES) = 0.0 TOTAL RUNOFF(CFS) = 0.11
TC(MIN.) = 0.85
FLOW PROCESS FROM NODE 7.3 TO NODE 7.4 IS CODE = 81 AREA A(22) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.587
NOTE: RAINFALL INTENSITY IS BASED ON Tc = 5-MINUTE.
GENERAL INDUSTRIAL RUNOFF COEFFICIENT = .8700
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 96
AREA-AVERAGE RUNOFF COEFFICIENT = 0.8700
SUBAREA AREA(ACRES) = 0.01 SUBAREA RUNOFF(CFS) = 0.06
TOTAL AREA(ACRES) = 0.0 TOTAL RUNOFF(CFS) = 0.17
TC(MIN.) = 0.85
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.0 TC(MIN.) = 0.85
PEAK FLOW RATE(CFS) = 0.17
END OF RATIONAL METHOD ANALYSIS
Page 2
100LAGPO. RES
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
2003,1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-2016 Advanced Engineering software (aes)
ver. 23.0 Release Date: 07/01/2016 License ID 1575
Analysis prepared by:
************************* DESCRIPTION OF STUDY * 100-YR POST-DEVELOPMENT * LAGUNA SUBDIVISION, CARLSBAD, CA * AREAS 18 AND 19, DRAINS TO BUENA VISTA LAGOON
FILE NAME: 100LAGPO.DAT
TIME/DATE OF STUDY: 10:28 05/28/2020 ----------------------------------------------------------------------------
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ----------------------------------------------------------------------------
2003 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES) = 2.500
SPECIFIED MINIMUM PIPE SIZE(INCH) = 4.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.85
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED FOR RATIONAL METHOD
NOTE: USE MODIFIED RATIONAL METHOD PROCEDURES FOR CONFLUENCE ANALYSIS
*USER_DEFINED STREET-SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL*
HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER-GEOMETRIES: MANNING
WIDTH CROSSFALL IN- / OUT-/PARK- HEIGHT WIDTH LIP HIKE FACTOR
NO. (FT) (FT) SIDE / SIDE! WAY (Fr) (Fr) (Fr) (Fr) (n)
1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0312.0.167 0.0150
GLOBAL STREET FLOW-DEPTH CONSTRAINTS:
Relative Flow-Depth = 0.67 FEET
as (Maximum Allowable Street Flow Depth) - (Top-of-Curb)
(Depth)*(Velocity) Constraint = 1.5 (FT*FT/S)
*SIZE PIPE WITH A FLOW CAPACITY GREATER THAN
OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.*
FLOW PROCESS FROM NODE 4.10 TO NODE 4.20 IS CODE = 21 AREA A(18) ----------------------------------------------------------------------------
>>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<<<<<
NATURAL DESERT LANDSCAPING RUNOFF COEFFICIENT = .2500
SOIL CLASSIFICATION IS "B"
S.C.S. CURVE NUMBER (AMC II) = 77
INITIAL SUBAREA FLOW-LENGTH(FEET) = 40.00
UPSTREAM ELEVATION(FEET) = 46.31
DOWNSTREAM ELEVATION(FEET) = 45.50
ELEVATION DIFFERENCE(FEET) = 0.81
SUBAREA OVERLAND TIME OF FLOW(MIN.) = 7.649
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 5.007
Page 1
100LAGPO. RES
SUBAREA RUNOFF(CFS) = 0.01
TOTAL AREA(ACRES) = 0.01 TOTAL RUNOFF(CFS) = 0.01
FLOW PROCESS FROM NODE 4.20 TO NODE 4.30 IS CODE = 81 AREA A(19) ----------------------------------------------------------------------------
>>>>>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW<<<<<
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 5.007
NATURAL DESERT LANDSCAPING RUNOFF COEFFICIENT = .2500
SOIL CLASSIFICATION IS t1B"
S.C.S. CURVE NUMBER (AMC II) = 77
AREA-AVERAGE RUNOFF COEFFICIENT = 0.2500
SUBAREA AREA(ACRES) = 0.28 SUBAREA RUNOFF(CFS) = 0.35
TOTAL AREA(ACRES) = 0.3 TOTAL RUNOFF(CFS) = 0.36
TC(MIN.) = 7.65
END OF STUDY SUMMARY:
TOTAL AREA(ACRES) = 0.3 TC(MIN.) = 7.65
PEAK FLOW RATE(CFS) = 0.36 -----------------
END OF RATIONAL METHOD ANALYSIS
r
Page 2
APPENDIX C
ISOPLU VIAL MAPS
WE
Page Left Intentionally Blank
WE
Storm Recurrance P6 (in) P24 (in) P6/P24
Yr
2 1.2 1.8 0.666667 ok
5 1.4 2.5 0.56 ok
10 1.6 3 0.533333 ok
25 2 3.5 0.571429 ok
50 2.25 4 0.5625 ok
100 2.5 4.5 0.555556 ok
85th percentile 1 0.6
Page Left Intentionally Blank
WE
Page Left Intentionally Blank
WE
APPENDIX D
PROJECT DRAINAGE AREA SCHEMATICS
WE
Page Left Intentionally Blank
WE
67~0-5'86 L4Jk DR1i' I (;#56k,c,c
flIG- D1,r) - I%(JPr& $64jTIc.
ril tJ0b$ ci
C)
09
Q I.M -01.,-Q12 &
10_c80 Lq .*R.Lc
ELq3~gj q.3
gal
IS)
APPENDIX E
HYDRAULIC CALCULATIONS,
EXISTING CONDITIONS
& PROPOSED CONDITIONS
WE
Page Left Intentionally Blank
WE
feet feet feet dimensionless feet radians SF feet Idis fps In ft
US EL OS EL L So n D alpha area pedmeteJQ V it T F
PI 43.8 43.6 19 Th523 0.013 0. 5.28 0.191 1.32 0.62 3.2 5.6 0.24 0.1
2 43.4 18 iiiii 0.013 0. 5.28 0.191 1.32 0.64 3.3 5.6 0.24 0.1
P3 43 43 35 0.011421 0.013 0. 5.28 0.191 1.32 0.65 3.4 5.6 0.24 0.1
4 4 42.5 446 11211 0.013 0 5.28 0.191 iJ 0.64 3.3 5.6 0.24 0.1
5 - 42.2 29- 0.013 0 5.28 0.191 1I 0.61 3.2 5.6 0.24 0.1
P8 42 42.2 655 - 0.013 0- 5.28 0.191 iij 0.00 0.0 5.6 0.24 0.00.
7 42.6 42.5 54 0.019519 0.013 0.5 5.28 0.191 iii 0.82 4.3 5.6 0.24 0.1
8 42.9 42.6 28 0.010714 0.013 0.5 5.28 0.191 ijj 0.62 3.3 5.6 0.24 0_1
P9 42.6 42.3 25.7 0.011673 0.013 0 5.28 0.191 ijj 0.65 3.4 5.6 0.24 0.1
piã 42.3 41.95 33 0.010605 0.013 0.5 5.28 0.191 12 0.62 3.2 5.6 0.24 0.1
p1i 41.95 41.5 43.3 0.010393 0.013 0.6 5.28 0.191 1.32 0.62 3.2 5.6 0.24 0.1
P12 -11. 41.5 75.5 0 0.013 0.5 5.28 0.191 1.2 0.00 0.0 5.6 0.24 0.00
Max QIOD from Hydrology
Check
0.07 ok
0.2 ok
0.33 ok
0.48 ok
0.51 ok
rains to aubgrade
0.03 ok
0.13 ok
0.26 ok
0.39 cit
0.41 cit
rains to subgrade
Plo. Capacity Check
Mannings Flow Evaluation of Pipe Capacities
dimensionless dimensionless
P13 44.25 42.5 65.35 0.026779 0.013 0.5 5.28 0.191 1.32 0.99 5.2 5.6 0.24 0.20 0.77 ok
P14 42.5 42.15 69.85_0.005011_0.013_0.5_5.28_0.191_1.32_0.43_2.2_5.6_0.24_0.08 1.27 will flow under pressure
P15 42.63 41.9 5.37 0.13594 0.013 0.5 5.28 0.191 1.32 2.23 11.6 5.6 0.24 0.441 2.19 will flow under pressure
US EL = Upstream elevation
OS EL - Downstream elevation
L = length of pipe
So = bed slope of pipe
n = Mannings roughness coefficient
D= diameter of pipe
alpha = internal angle from angle point at center of pipe measured from 0 at empty to 6.28 radians when full
area = area of flow in pipe
perimeter = wetted perimeter of flow
0 = peak flow rate
V velocity of flow
h= head In pipe
T =top width of flow
F = Froude Number
Half clogged
Q = 3.0 x 3 x (H)A(3/2)
Q (cfs) IH (if) I H (in)
0.7702161 0.1941991 2.330385
1.2703541 0.2710951 3.253141
Weir Equation
Check Inlet Capacity
Peak flow to Inlets in rear of units 10, 11, 12, 13 and sides of 13 = 0.51 cfs
Peak flow to Inlets in rear of units 7, 8, 9 = 0.41 cfs
Peak flow on site = 2.19 cfs Th
Q 1 to Q100 for brooks boxes = 0.01 cfs to 0.15 cfs
Weir Equation:
QCx L x HA(3/2)
C = 3.0
L = length of weir
1' x 1' Brooks Box
L = 4, assume 50% dogging, L' = 2'
H - head over weir crest
Assume approach flow is max 0.6
H = OR
Q3.0x2x(H)"(3/2)
Q(cfs) H(ft) IH(in)
0.0104761 0.01451 0.174
0.5126891 0.1941 2.328
Two central 18 x 18 boxes were added to the design in case
there are other on-site failures
For these, assume L = 6' and assume 25% clogging, L'1.5'
Q = 3.0 x 1.5 x(H)"(312)
Q (cfs) H (ft) H (in)
0.770135 0.30825 3.699
1.2699821 0.4302521 5.163029
Q (cfs) IH (ft) 1H (in) Since the are two of these boxes, evaluate Qpeak/2 = 1.27/2 =
0.6357351 0.2712541 3.255046
All on-site rear-yard inlets are provided with sufficient capacity to drain with less than 2.3-in, of approach flow head and half clogged.
Inlet 2 in driveway provides with sufficient capacity to drain all site interior drainage with inlet 1 clogged and an approach flow of 5 inches
and if the inlet 2 is 3/4 clogged.
Inlet 2 can pass 1.27 cfs with 50% clogging with approach flow of 3.25 inches.
0.635
FE54gE Vt.DV4I M4s4 Fox
L.echwa cDwiclo1, C4.LsBfti,c.4
"pg 5T7 16~w
I 1(J 'f,Zoo
tt6rhh1 F CFI'J1AL pfeer SyfrEN
frJi.it
/
I I (0 JU
I *fE
14
forfl.
r
lei i'f2.Ib'
-4 It..*ntç 1(*Tiø) Th /1D Loj( i'd
ik
Zi o5 Z9^401 1LI4r$ 61?L4krft4 (tic.Mw,r; Q O3Z t 49b TF4fDJf, jJ 4cpfw,T(t (i/firE(g,t4 q8
& Fteo MTh
C . K ,4-t$IIt.fA,'7S f't"
PIfE (c'r
fEt.roiJ SvP
jI1cf. (r
1. LP 1( oF spE (ST)
Fo' pf+zF46b*Y V4Lue.~DF C:
Folk S11r ,,0.tH'PE5
dp
c.-.-/,tc
o/ o J?tfRoiJ $ICk wogic C
f M! 120
aL5 1 p1i4o
2- i.' r h7*
a
R1446e J14ZJ41II-'./40",f t4'
/0
--243 zi) (M3ZxCa /
I..
Af'P(I S ru:
sc
(I. v+c4s)
(Ito) )C. I.b3
1.3'
END aP/y
2.
c9 I. 27 cc5 Y X,4 v X - 1TAt... v
l4V '•'t4' lf_
(4)t 0.32' (o.c) i&
\
32./ -
dqI4ø't k:oS
k ++ 9q.25'-f-o32'= -4-50
VR 4.4 /
'. 51 i4*CCt 'O.1 ' Z
Ic 4 ,a.ote_ 414. 10"— q2.z' = l.5'
'. a'i- rt.l? . PIPE '2.b3 tIS
-: O,l C D •
OM3 4103,( (b.9) (c')
"4<
v g'#LLfA-7 p/ps p,'c Aomw roi II1IJIOI A 3J
L q.3 ' (z's) :b
t.
)
-._. - ' 1,//
&'' 48 (j2o)x (i7.?S -
L '1-'!.'!' 4-o.3'/'
034 ' 4:4. Alto uAP j4h.1Z.
1M.M Y2.0 Z.'I &.mJ Orl
O.IJs.2.11 v o.21c fs
4DD çb ?t1Rk.4ft D ,, (oI7- err s)
v.%•* 629s A li C45
PKE-SiOlo PLOW
,zb3 ,t &2-))(
&'Lc
(.2zthc(. 4'b 5WEt
4-
olticcs frpikwy
I.34c.4s
3
2%
Concrete
Gutter
= .015—+.
n.0175
tepth paved 7' ~0.13~W~4~R~ESIIDENTIMA
NLY
MONARENN — I INNEEN
=~~WMMMMFANNNIF,ii FA
WA FA
•
4 VA•!T1
A
FlU
•
WA m
A.- ONF INEWAMEIFANNI NOW, WA IN N •
•
AJ m
ANIFA
Fm 0 W, * OR a rlmlmvl
A!A VA WWUWA
WIAU
Ih qhh b., I FA --
___-_____
ia u
____
— AA
I
.
___ ___•
Sol
fjmj
AN
l!iW UI OOM!
m!m qVII,
WE W.-ANNNEWAINI'mor
=b,.k PA IMINFARREN
MONO MAMME ME - ! mmbW7-~ WA I I III WA I N U U
I. ___... --
1 I3i c4 6 2 3
Dcharge(C.F.S.)
EXAMPLE:
Glven:QIO S.2.5%
Chart gives: Depth = 0.4, Velocity = 4.4 fps.
SOURCE: San Diego County Department of Special District Services Design Manual
20 .30 40 50
FIGURE
Gutter and Roadway Discharge - Velocity Chart
Appendix F
Reference Materials from Geotechnical Report
WE
Page Left Intentionally Blank
WE
LOG OF EXPLORATORY BORING NO. 1
DRILL RIG: TRUCK-MOUNTED HOLLOW-STEM AUGER PROJECT NO. P.686218
BORING DIAMETER: 8.08 DATE DRILLED: 03-16-18
SURFACE ELEV.: 42.5' (Approximate) LOGGED BY: AG
0 d cfl
Z ° <
GEOLOGIC DESCRIPTION
42.54
- °°° SM SOIL(Qs): Reddish Dk. Brn. fine grained sand, silty, organics
SP PARALIC DEPOSITS (Qop): Reddish brn., fine and med.-grained san
117.0 2.6 1 - 37.5O4
SPT 23.0 40 ] 300
109.7 2.2 ______32.5 ____ SPT 11.5 34 10.0
Light red fine and coarse-grained sand, slightly moist pebbles
110.0 6.5 27.50J! SPT 14.9 50 15.0 White to gray-light orange fine and coarse-grained sand
Gravc!-Pebble Layer
122.1
SPT
8.9 27.0 50
22.5 20. SC SANTIAGO FORMATION (Tsa): Gray-Pale Green clayey sandstone
- 17.5
SPT 50 - 25.
E 12.3
118.6 9.2 f -= 30.0
= 7.50 Fine and coarse-grained claycy sandstone is dense ro very dens
SPT 26.5 50 ]
= 35.0
Distrube 1 8.3 = 2.50
SPT 25.2 50 = 40.00
= -2.50 End of Boring @ 50'. No Groundwater
SPT 50 ] 45.9 Some caving due to auger removal
Backfilled with hydrated bentonite
- -7.50
- SPT 27.2 1 50 = so.
SHEET 1 OF 1 COAST GEOTECHNICAL Figure
LOG OF EXPLORATORY BORING NO. 2
DRILL RIG: TRUCK-MOUNTED HOLLOW-STEM AUGER PROJECT NO. P686218
BORING DIAMETER: 8.0" DATE DRILLED: 03-16-18
SURFACE ELEV.: 43.3' (Approximate) LOGGED BY: AG
1-.
U)
z ° U)
('I
U)
z Z z -
-
0 '-2 ,
I-. U) U,
GEOLOGIC DESCRIPTION
43.3 -
- 0.00 SM
i... SP
SOIL(Qs): Reddish Dk. Brn. fine grained sand, silty, organics
PARALIC DEPOSITS (Qop): Reddish bm., fine and med.-grained saw
126.4 8.5 38.3 SPT 27.8 22
j
-5.00
Light red fine and coarsc-graincd sand, slightly moist pebbles
104.2 6.5 33.3 White to gray-light orange fine and coarse-grained sand SPT 12.8 Gravel-Pebble layer
Sample Distrub
SPT 11.6 43 150
106.6
SPT
6.7
24.4 50
23.3 SC SANTIAGO FORMATION (Tsa): Gray-Pale Green clayey sandstone
- 20.
Fine and coarse-grained clayey sandstone is dense ro very dens
18.3 SPT - 50
]
25.
- End of Boring @ 30'. No Groundwater
Some caving due to auger removal
- Backfihled with hydrated bentonite
- 13.3
SPT 24.4 50 30.
SHEET 1 OF 1 COAST GEOTECHNICAL Figure 5
Appendix G
FEMA FIRM Panel
WE
Page Left Intentionally Blank
WE
National Flood Hazard Layer FiRMette *FEMA Legend
V
1010V05"N SEE FIS REPORTFOR DETAILED LEGEND AND INDEX MAP FOR FIRM PANEL LAYOUT
Without Base Flood Elevation (BFE)
SPECIAL FLOOD With BFE or Depth Zone RE, AO, AR, VE. AR
HAZARD AREAS Regulatory Floodway
V V
0.2% Annual Chance Flood Hazard, Areas
N
• '- 5 '5- -. ofl% annual chance flood with average low - -. .- . ' depth less than one foot or with drainage
-
. . areas of less than one square mile Zone X
S - S S ' ?- _V• _______ Future Conditions 1% Annual
- ' Chance Flood Hazard zone
V • - Area with Reduced flood Risk due to %- - HER AREAS OF Levee. See Notes. Zone X c7, LOOD HAZARD P',' Area with Flood Risk due to Leveezono 0
*VV - o scREENI Area of Minimal Flood Hazard Zone X
I I Effective LOMRs
S S V OOr V5 V .1 4 * '9 OTHER AREAS Area of Undetermined Flood Hazard ZoneD
V
V
V * GENERAL - — - - Channel, Culvert, or Storm Sewer
STRUCTURES 'liii'' Levee, Dike, or Floodwall
V - .. •VS5 Cross Sections with 1% Annual Chance
.
' o .PW . 4 V _.iZ. Water Surface Elevation
®—--CoastalTransect I I V _,.Base Flood Elevation Line (BFE)
V -A
Limit of Study
V V - S S. V CSV ---- Jurisdiction Boundary so -- . V V5 • (T°I - S
VS V ••' - . . ' --- Coastal Transect Baseline R D, OTHER - — Profile Baseline
I -
FEATURES Hydrographic Feature
40 V-Yr_S___I• Digital Data Available N
El No Digital Data Available
MAP PANELS L Unmapped
r° S
i - I The pin displayed on the map s an approximate Ri
-n - , point selected by the user and does not represent
. anauthontative property location.
Ilk t V i' _, S V - This map complies with FEMAs standards for the use of
V • \ ( - digital flood maps ifitis not void as described below.
V - . .c ,;°- 'sj- The basemap shown complies with FEMA's basemap
acc uracy standards
A . . •S V '- The flood hazard information is derived directly from the it
V. *
' - 4 - ,•S - authoritative NFHL web services provided by FEMA. This map
S T . - 4iV • V %J was exported on 4/7/2020 at 7:43:21 AM and does not
* t •0 . .' ? reflect changes or amendments subsequent to this date and - -S . • I . , a time. The NFHL and effective information may change or - aV •
S S n- .-' , become superseded by new data overtime. -' ,
5 V• 'S S !' ir
0 This map Image is void lf the one or more of the following map
V
V
V-S VS •% V • - \•V -
V elements do not appear basemap imagery, flood zone labels,
I legend scale bar, map creation date community identifiers I 1 Ft V C _.. V V V V_ FIRM panel number, and FIRM effective date. Map images for
- — Feet 1:6,000 -93"N unmapped and unmodernized areas cannot be used for
0 250 500 1,000 1,500 2,000 regulatory purposes.