HomeMy WebLinkAbout1545 FARADAY AVE; 100; CBC2021-0319; PermitPERMIT REPORT
(city of
Carlsbad
Commercial Permit
Print Date: 03/24/2022 Permit No: CBC2021-0319
Job Address: 1545 FARADAY AVE, # 100, CARLSBAD, CA 92008-7450 Status: Closed -Finaled
Permit Type: BLDG-Commercial Work Class: Tenant Improvement
Parcel#: 2121302900 Track#:
Valuation: $276,176.38 Lot#:
Occupancy Group: B Project#:
#of Dwelling Units: Plan#:
Bedrooms: Construction Type:V-8
Bathrooms: Orig. Plan Check#:
Plan Check#:
Project Title:
Description: CAPSTONE: 5,938 SF T.I. (OFFICE TO OFFICE)
Property Owner:
FEE
CW H Q CARLSBAD LLC
1545 FARADAY AVE
CARLSBAD, CA 92008
COMM RES & MULTI RES REMODELS-NON-STRUCTURAL
581473 -GREEN BUILDING STATE STANDARDS FEE
BUILDING PLAN CHECK FEE (BLDG)
STRONG MOTION -COMMERCIAL (SMIP)
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
BUILDING PLAN REVIEW-MINOR PROJECTS (LOE)
BUILDING PLAN REVIEW-MINOR PROJECTS (PLN)
Total Fees: $3,668.81 Total Payments To Date: $3,668.81
Applied: 08/25/2021
Issued: 10/20/2021
Finaled Close Out: 03/24/2022
Inspector:
Final Inspection:
Contractor:
TAlva
12/14/2021
SPW CONSTRUCTION DBA WHITE
CONSTRUCTION
2524 GATEWAY RD
CARLSBAD, CA 92009
(760) 931-1130
Balance Due:
AMOUNT
$2,234.44
$12.00
$878.04
$77.33
$175.00
$194.00
$98.00
$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
( City of
Carlsbad
Job Address 1545 Faraday Avenue
COMMERCIAL
BUILDING PERMIT
APPLICATION
B-2
Plan Check cgt:r, ~-Q;/9
Est. Value 7 7-J, 3-
PC Deposit
Date
Suite: :#{QO APN:,_2_12_-_13_0_-2_9 ______ _
Tenant Name #:_C_a.,_p_st_o_n_e _____________ Lot #: ____ Year Built: _________ _
Year Built:, __ _ Occupancy: 8 (office) Construction Type: V-N Fire sprinklers@ESQNO A/C:QYESQNO
BRIEF DESCRIPTION OF WORK: minor demo and new structural for new office glass system (interior), new storefront door, lighting
and finishes
D Addition/New: ____________ New SF and Use, __________ New SF and Use
_______ SF Deck, _______ SF Patio Cover, ________ SF Other (Specify) ___ _
IZ]Tenant Improvement: .:.5:..:,9.:.3.:.8 ___ SF, Existing Use: _o_ff_ic_e _____ Proposed Use: _off_i_ce ____ _
_____ SF, Existing Use: Proposed Use: ______ _
D Pool/Spa:. _____ SF Additional Gas or Electrical Features? ____________ ~
D Solar: ___ KW, ___ Modules, Mounted: 0Roof 0Ground
D Reroof:. ____________________________________ _
IZ] Plumbing/Mechanical/Electrical no plumbing, duct work only for mechancial, minor electric~
Dother: ______________________________ _
PRIMARY APPLICANT
Name:SPW Construction (White Construction)
Address: 2524 Gateway Road
City: Carlsbad State:._C_A_~Zip: 92009
Phone: 760.931.1130
Email: nancy@wh iteconstruction inc.com
PROPERTY OWNER
Name: CWHQ Carlsbad, LLC c/o Capstone Advisors
Address: 1545 Faraday Avenue
City: Carlsbad state: CA Zip:._9_2_0_08 __ _
Phone: 760.804.6900 x 11 O
Email: johnston@capstoneadvisors.com
DESIGN PROFESSIONAL CONTRACTOR OF RECORD
Name:McCulley Design Lab Business Name:SPW Construction (White Construction)
Address:224 South Cedros Avenue Studio A Address:2524 Gateway Road
City: Solana Beach State: CA Zip:,_9_2_07_5 ___ City: Carlsbad State.:_ C_A __ Zip: 92009
Phone:858. 756.1807 Phone: 760. 731.1130
Email: amanda@mcculleydesign.com Email: nancy@whiteconstructioninc.com
Architect State License: __________ _ CSLB License#: 1023856 Class:B ·-------
Carlsbad Business License# (Required): BLNR000431-02-2017
APPLICANT CERT/FICA TION: I certify that I have read the application and state that the above information is correct and that the
information on the plans is accurate. /agree to comply with all City ordinances and State laws relating to building
construction.
NAME (PRINT): Nancy Young, PM SIGN: J/"V'>c-g DATE: 8/23/2021
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: f?u1_l_d1_ng@~Jrl',b,H.icd.gov
REV. 07/21
THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _
A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON
SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO
PERMIT ISSUANCE.
(OPTION A): LICENSED CONTRACTOR DECLARATION:
I herebyaffi rm under penalty af per jury that/ am I icensed under provisions of Chapter 9 (commencing with Section 7000 / of Division 3
of the Business and Professions Code, and my I icense is in full force and effect. I also affirm under penalty of perjury one of the
following declarations (CHOOSE ONE):
D1 have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit 1s issued. Policy No. ________________________________________ _
-0R-
~I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
My workers' compensation insurance carrier and policy number are: lnsuranceCompany Name: _s_ea_te_c_o_m~p,_,_~_,,_oc_,_cs_._Fo_c_d _____________ _
Policy No. 9243036-21 Expiration Date: _11_,_,,_02_2 _____________ _
-0R-
Ocertificate of Exemption: I certify that 1n the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become
subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code,
interest and attorney's fees.
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction lending agency for the performance of the work this permit IS issued (Sec. 3097 (i} Civil Code),
Lender's Name:. _____________________ Lender's Address: _____________________ _
CONTRACTOR CERTIFICATION: /certify that/ have read the application and state that the above information is correct and that
the information on the plans is accurate. /agree to comply with all City ordinances and State laws relating to building
construction.
· OR -
(OPTION B): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure 1s not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such
work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
-0R-D1, as owner of the property, am exclusively contracting with licensed contractors to construct the project {Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
-0R-□1 am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason:
.\~I).
D FORM B-61 "Owner Builder Acknowledgement and Verification Form" is required for any permit issued to a property owner.
By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the
improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed
contractors. I understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application is
submitted or at the following Web site: http:Ilwww.leginfo.ca.govl ca/aw. html.
OWNER CERT/FICA T/ON: I certify that I have read the application and state that the above information is correct and that the
information on the plansisaccurate. /agree to comply with all City ordinances and State laws relating to building
construction.
NAME (PRINT): _________ _ SIGN: __________ DATE: ______ _
Note: If the person signing above is an authorized agent for the property owner include form B-62 signed by property owner.
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-85S8 Email Budding@carlsbadca.gov
2 REV 07/21
PERMIT INSPECTION HISTORY for (CBC2021-0319)
Permit Type: BLDG-Commercial
Work Class: Tenant Improvement
Application Date: 08/25/2021
Issue Date: 10/20/2021
Owner: C W H Q CARLSBAD LLC
Subdivision: CARLSBAD TCT#85-24 UNIT#05
Address: 1545 FARADAY AVE, # 100 Status: Closed -Finaled Expiration Date: 05/23/2022
IVR Number: 35497 CARLSBAD, CA 92008-7450
Scheduled
Date
11/22/2021
12/14/2021
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector
11/22/2021
12/14/2021
Checklist Item
BLDG-Building Deficiency
COMMENTS
Rough frame combination Inspection for
interior tenant improvement Shell.
non-loadbearing steel framed (structural
steel) partition walls-approved per plan.
Shearwall fastening method of attachment
alteration, located in office area -
approved per plan.
BLDG-84 Rough
Combo(14,24,34,44)
171122-2021 Passed Tony Alvarado
Checklist Item
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
COMMENTS
Rough frame combination Inspection for
interior tenant improvement Shell.
non-foadbearing steel framed (structural
steel) partition walls-approved per plan.
Shearwall fastening method of attachment
alteration, located in office area -
approved per plan.
Rough frame combination Inspection for
interior tenant improvement Shell.
non-loadbearing steel framed (structural
steel) partition walls-approved per plan.
Shearwall fastening method of attachment
alteration, located in office area -
approved per plan.
Rough frame combination Inspection for
interior tenant improvement Shell.
non-loadbearing steel framed (structural
steel) partition walls-approved per plan.
Shearwall fastening method of attachment
alteration, located in office area -
approved per plan.
BLDG-17 Interior 171201-2021 Passed Tony Alvarado
Lath/Drywall
Checklist Item COMMENTS
BLDG-Building Deficiency
BLDG-Final Inspection 172639-2021 Passed Tony Alvarado
Checklist Item COMMENTS
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
Thursday, March 24, 2022
Reinspection Inspection
Passed
Yes
Complete
Passed
Yes
Yes
Yes
Complete
Passed
No
Complete
Passed
Yes
Yes
Yes
Page 2 of 2
Building Permit Inspection History Finaled
( City of
Carlsbad
PERMIT INSPECTION HISTORY for (CBC2021-0319)
Permit Type: BLDG-Commercial
Work Class: Tenant Improvement
Status: Closed -Finaled
Scheduled Actual Inspection Type
Date Start Date
10/2512021 10125/2021 BLDG-21
Underground/LI nderflo
or Plumbing
Checklist Item
Application Date: 08/25/2021
Issue Date: 10/20/2021
Expiration Date: 05/23/2022
IVR Number:
Inspection No.
169231-2021
COMMENTS
35497
Inspection
Status
Passed
Owner: CW HQ CARLSBAD LLC
Subdivision: CARLSBAD TCT#85-24 UNIT#05
Address: 1545 FARADAY AVE, # 100
CARLSBAD, CA 92008-7450
Primary Inspector Reinspection Inspection
Tony Alvarado Complete
Passed
BLDG-Building Deficiency October 25, 2021: Yes
1111012021
11/1912021
BLDG-31
Underground/Conduit -
Wiring
Checklist Item
1. No building Deficiencies.
2. Underground electrical conduit, no new
electrical circuit added, scope of electrical
work-approved.
3. interior tenant improvement, with no
alterations to existing exterior structure.
169244-2021 Passed Tony Alvarado
COMMENTS
BLDG-Building Deficiency October 25, 2021:
11/1012021 BLDG-14
FramefSteel/Boltlng/We
lding (Decks)
Checklist Item
1. No building Deficiencies.
2. Underground electrical conduit. no new
electrical circuit added, scope of electrical
work-approved.
3. interior tenant improvement, with no
alterations to existing exterior structure.
170517-2021 Passed Tony Alvarado
COMMENTS
BLDG-Building Deficiency November 10, 2021:
11/19/2021 BLDG-13 Shear
Panels/HD (ok to wrap)
1. No framing Building Deficiencies.
2. Interior structural moment frame
connections and footings approved per
revised structural engineer's plan,
structural calculations, third-party deputy
inspector, and structural engineer's
calculations, for interior alterations (only)-
approved.
3. Rough electrical min. alterations, located
at (e)structural loadbearing wall, office
number unit area #108, scope of electrical
work -approved.
4. OK to cover with shear plywood.
171155-2021 Passed Tony Alvarado
Thursday, March 24, 2022
Complete
Passed
Yes
Complete
Passed
Yes
Complete
Page 1 of 2
Inspection Report
Project Name: __ C_a~p_s_t_o_n_e_H_Q ___ _ Page: _1_ of _1_ Report# ____ _
Project Address: __ 1..,5..,;4=u.5'-'-F ..... a..,ru.a...,d ........ a'--JyL---L-'a .... vu.e~--
Architect:
Permit#: Cbc2021-0139
File#: --------------------------------
DSA#: Engineer: __ ~~~---------------------------White Contractor: _________________ _ Other: ____________ _
INSPECTION MATERIAL SAMPLING QTY MATERIAL DESCRIPTION INSPECTION CHECKLIST
-Structural Steel -H.S. Bolts -H.S. Bolts .L... Plans/Specs
_ Masonry Prisms Cone. PSI Clearances ---
-Concrete Mortar/ Grout -Grout PSI -Positions
Fireproofing _ Cone. Cylinders Mortar PSI .L... Sizes
7 Epoxy _ Fireproof 7 Steel 7/8" _ Laps
-Other: -Other: Elect./Wire -Consolidation
Other: Other: _ Fireproof _ Torque Ft. Lbs: --
-Other: -Other: L Other: .L_ Other: 15" Embed
Other: Other: L Other: Simpsca XP .L... Other: 2508
Performed special inspection on the installation of
2 total 7/8 all thread retrofit HDl JS baldawn baits into existing
foundation per detail 2/S1
Verified bolt, bar types, sizes, hole sizes, depth, location,
cleanliness, and epoxy type prior to installation.
CERTIFICATION OF COMPLIANCE: All reported work, unless otherwise noted, complies with approved plans, specifications and applicable sections
of the building codes. This report covers the locations of the work inspected and does not constitute opinion or project control.
I hereby certify that I have observed to the best of my knowledge all of the above reported work unless otherwise noted. I have found this work to
comply with the approved plans, specifications, and applicable sections of the governing building laws.
INSPECTOR: GIANNI BATTAGLIA CERT: 1323 ~ 11-9-21
Signature Date
lnsp. Date: Day 1: I Day 2: I Day 3: I Day 4: I Day 5: I
Time Start:
Time Stop:
Approved By: __________ _
I
I
'
'
tel -818-6Jl-8900
hee -855-787-4522
tax -B58-6n-9009
Patri-011.at.com
6640 Lusk Blvd_, Suite A-100, San Diego, CA 92121
September 8, 2021
Nancy Young
White Construction Inc.
2524 Gateway Road
Carlsbad, CA 92009
Re: Limited Asbestos Survey
Capstone
1545 Faraday Avenue, Suite 100
Carlsbad, CA 92008
Job No: 14867
Project No: SD 150095
Dear Ms. Young,
PA Environmentar Laboratory Services, Inc.
On September 7. 2021, California DOSH Certified Site Surveillance Technician, Mr. Brennan
Bales (CSST # 19-6731) of Patriot Environmental Laboratory Services, Inc. (Patriot) performed a
limited asbestos inspection at the above subject property located in Carlsbad, California. The
purpose of the inspection was to determine if asbestos is present in the building materials soon to
be disturbed by an upcoming renovation at the subject property.
Summary of Findings
No asbestos was detected in the building materials sampled.
Property Description
The subject property is a commercial structure. The subject building is a two-story metal frame
building set on a cement slab foundation.
Scope of Work
On September 7, 2021, Mr. Brennan Bales, (CSST # 19-6731) of Patriot conducted a limited
asbestos inspection at the subject property. The interior of the building was visually inspected for
the purpose of identifying suspect asbestos containing materials soon to be disturbed by an
upcoming renovation at the subject property. Once the inventory of suspect materials was
created, physical bulk samples of the materials were collected from representative locations.
Samples were collected in airtight containers. Upon collection, sample numbers, descriptions,
and collection locations were entered on to a chain of custody for transportation to Patriot's
NVLAP accredited laboratory.
Sampled Suspect Materials
Samples of the following suspect materials were collected:
4" Grey Cove Base with Mastic
Car et Tile Mastic
Sample Protocol/Analysis
4" Black Cove Base with
Mastic
Bamboo Floorin Adhesive
l 2"x 12" Black Vinyl Floor Tile
with Mastic
Samples were collected in accordance with the Asbestos Hazard Emergency Response Act ( 40
CFR 763 Subpart E) as mandated by Cal/OSHA (Title 8 Section 1529) and San Diego Air
Pollution Control District Rule 1206.
Physical bulk samples were analyzed by Patriot. Patriot is accredited by the National Voluntary
Laboratory Accreditation Program (200982). The method of analysis was Polarized Light
Microscopy (EPA 600/M4-82-020).
Recommendations
No asbestos was detected in the building materials sampled. Therefore, no recommendations are
warranted at this time.
Disclaimer
Limited destructive sampling was conducted at the subject property. If additional suspect
materials are discovered during renovation, all work should cease until a Certified Asbestos
Consultant is contracted to determine the asbestos content of the building materials. This
inspection was performed in accordance with current regulations and state of the art practices.
The inventory of asbestos containing materials and determination of their condition are based
upon observations at the time of inspection. Patriot does not assume responsibility for future
regulatory changes or changes in the condition of the building or materials.
Enclosed is the laboratory analysis report and sample location diagram. Please contact our office
if there are any questions regarding this inspection.
Sincerely,
Patriot Environmental Laboratory Services, Inc.
fr
Zach Levin
Certified Asbestos Consultant No. 16-5772
Attachments:
Laboratory Resu Its
Sample Location Diagram
Certifications
Certificate of Analysis
PLM Asbestos Identification
White Construction Inc.
Nancy Young
2524 Gateway Road
Carlsbad, CA 92009
Date Collected: 9nl2021
Date Received: 9n!2021
Date Analyzed, 9/8/2021
Date Reported: 9/8/2021
Lab/Client ID/Layer Location
878108-001 0.0 -Wall
Total Asbestos None Detected
878108-002 0.0-Wall
2
Total Asbestos None Detected
878108-002C 0.0 -Wall
2
Total Asbestos None Detected
878108-003 0.0 -Wall
3
Total Asbestos None Detected
878108-004 0.0 -Wall
4
Total Asbestos None Detected
1e1 -ass-m-sm
lree -8lH8Hm
S[)l,~j!ipalriotfa~.(0111 DA'1 m~T LAB
li/,,10 LlllJc Blvd., lule A·IOO, S.R !lie9o, (A 92111 .-"' .:JJ'
Report Number: 878108
Project Number: SO150095
Project Name: Capstone
Project Location: 1545 Faraday A venue Suite I 00
Carlsbad, CA 92008
Collected By: Brennan Bales
Claim Number: Job #14867
PO Number,
Number of Samples: 51
Material Description Color Composition ( % )
Drywall White 70% Non-
Fibrous Material
25% Cellulose
5% Glass Fibers
Joint Compound White 100% Non-
Fibrous Material
Drywall and Joint White 80% Sulfate
Compound 10% Cellulose
6% Carbonate
2 % Glass Fibers
2% Paint
Drywall White 70% Non-
Fibrous Material
25% Cellulose
5% Glass Fibers
Joint Compound White 100% Non-
Fibrous Material
Page I of 10
Certificate of Analysis
PLM Asbestos Identification
White Construction Inc.
Nancy Young
2524 Gateway Road
Carlsbad, CA 92009
Date Collected: 9/7/2021
Date Received: 9/7/2021
Date Analyzed: 9/8/2021
Date Reported: 9/8/2021
Lab/Client ID/Layer
878108-004C
4
Total Asbestos
878108-005
5
Total Asbestos
878108-006
6
Total Asbestos
878108-006C
6
Total Asbestos
878108-007
7
Total Asbestos
Location
0.0 -Wall
None Detected
106-Wall
None Detected
106-Wall
None Detected
106 -Wall
None Detected
102 -Wall
None Detected
tel -8,8-&54-5117
lree • 8ll· l8Hm
IDlab@palriot~ll.com n A I , ,::w~T LAB
6640 Lllll< 81Yd., lule A-100, San l)iego, 0. 92111 .-'"' , • .:J'
Report Number: 878108
Project Number: SDl50095
Project Name: Capstone
Project Location: 1545 Faraday A venue Suite I 00
Carlsbad, CA 92008
Collected By: Brennan Bales
Claim Number: Job #14867
PO Number:
Number of Samples: 51
Material Description
Drywall and Joint
Compound
Drywall
Joint Compound
Drywall and Joint
Compound
Drywall
Color
White
White
White
White
White
Composition ( % )
80% Sulfate
I 0% Cellulose
6% Carbonate
2% Glass Fibers
2% Paint
70% Non-
Fibrous Material
25% Cellulose
5% Glass Fibers
100% Non-
Fibrous Material
80% Sulfate
10% Cellulose
6% Carbonate
2% Glass Fibers
2% Paint
70% Non-
Fibrous Material
25% Cellulose
5% Glass Fibers
Page 2 of 10
Certificate of Analysis
PLM Asbestos Identification
White Construction Inc.
Nancy Young
2524 Gateway Road
Carlsbad, CA 92009
Date Collected: 9/7/2021
Date Received: 9/7/2021
Date Analyzed: 9/8/2021
Date Reported: 9/8/2021
Lab/Client ID/Layer
878108-008
8
Total Asbestos
878108-008C
8
Total Asbestos
878108-009
9
Total Asbestos
878108-010
IO
Total Asbestos
878108-0I0C
10
Total Asbestos
Location
102 -Wall
None Detected
102 -Wall
None Detected
103 -Wall
None Detected
103-Wall
None Detected
103-Wall
None Detected
lei -BSS-.il->227
l~e -8ll-J8Mll7
sm,1>o,patriot1,1uo111 DA•, , ... ~T LAB
6640 ltJsk Blv,L Su~• A-100, SanfJl!11'), CA 92121 .-" ,.~
Report Number: 878108
Project Number: SD150095
Project Name: Capstone
Project Location: 1545 Faraday Avenue Suite 100
Carlsbad, CA 92008
Collected By: Brennan Bales
Claim Number: Job #14867
PO Number:
Number of Samples: 51
Material Description Color Composition ( % )
Joint Compound
Drywall and Joint
Compound
Drywall
Joint Compound
Drywall and Joint
Compound
White
White
White
White
White
100% Non-
Fibrous Material
80% Sulfate
10% Cellulose
6% Carbonate
2% Glass Fibers
2% Paint
70% Non-
Fibrous Material
25% Cellulose
5% Glass Fibers
100% Non-
Fibrous Material
80% Sulfate
10% Cellulose
6% Carbonate
2% Glass Fibers
2% Paint
Page 3 of 10
Certificate of Analysis
PLM Asbestos Identification
White Construction Inc.
Nancy Young
2524 Gateway Road
Carlsbad, CA 92009
Date Collected: 9/712021
Date Received: 9/7/2021
Date Analyzed: 9/8/2021
Date Reported: 9/8/2021
Lab/Client ID/Layer
878108-011
I I
Total Asbestos
878108-012
12
Total Asbestos
878108-013
13
Total Asbestos
878 I 08-014
14
Total Asbestos
878108-015
15
Total Asbestos
878108-016
16
Total Asbestos
Location
0.0 -Wall
None Detected
0.0 -Wall
None Detected
106 -Wall
None Detected
102 -Wall
None Detected
103-Wall
None Detected
I 06 -Ceiling
None Detected
lel · 8S3-654-Sll7
tree -8l3· l8l-lll7
IOI.JIJ(•'patri<lllab.com n A I • ,-~T LAB
fil>40 Llllk Blvd,. lu~eA-100, San Diego, CA 92111 ■--"' ,■.:,
Report Number: 878108
Project Number: SD150095
Project Name: Capstone
Project Location: 1545 Faraday Avenue Suite 100
Carlsbad, CA 92008
Collected By: Brennan Bales
Claim Number: Job #14867
PO Number:
Number of Samples: 51
Material Description Color Composition ( % )
Wall Texture White
Wall Texture White
Wal I Texture White
Wall Texture White
Wa11 Texture White
Ceiling Tile Grey
100% Non-
Fibrous Material
100% Non-
Fibrous Material
100% Non-
Fibrous Material
100% Non-
Fi bro us Material
100% Non-
Fibrous Material
73% Cellulose
22% Minerals
5% Glass Fibers
Page 4 of 10
Certificate of Analysis
PLM Asbestos Identification tel · 818-654-1111
lree · 83H8Hl27
SDla~~•palrioll.lb,com nA·. ,:sa~T LAB
tiMO L~ Bh,t, lu~d-100, San Diego, CA 92111 .--"". ,■ ~
White Construction Inc.
Nancy Young
2524 Gateway Road
Carlsbad, CA 92009
Date Collected: 9n /2021
Date Received: 9/7/2021
Date Analyzed: 9/8/2021
Date Reported: 9/8/2021
Lab/Client ID/Layer
878108-017
17
Total Asbestos
878108-018
18
Total Asbestos
878108-019
19
Total Asbestos
878108-020
20
Total Asbestos
878108-021
21
Total Asbestos
878108-022
22
Total Asbestos
Location
106 -Ceiling
None Detected
103 · Ceiling
None Detected
103 -Wall
None Detected
103 -Wall
None Detected
102 -Wall
None Detected
102-Wall
None Detected
Report Number:
Project Number:
Project Name:
Project Location:
Collected By:
Claim Number:
PO Number:
878108
SD150095
Capstone
1545 Faraday Avenue Suite 100
Carlsbad, CA 92008
Brennan Bales
Job #14867
Number of Samples: 51
Material Description Color Composition ( % )
Ceiling Tile Grey
Ceiling Tile Grey
4 Inch Cove Base Black
Mastic Yellow
4 Inch Cove Base Black
Mastic Yellow
73% Cellulose
22% Minerals
5% Glass Fibers
73% Cellulose
22% Minerals
5% Glass Fibers
100% Non-
Fibrous Material
100% Non-
Fibrous Material
100% Non-
Fibrous Material
100% Non-
Fibrous Material
Page 5 of 10
Certificate of Analysis
PLM Asbestos Identification lei • 8SH54·5111 r,ee · SlH8J.S117
SOLl~~:p;atrtotl;aluom nA•. ,-~T LAB
6640 tu;k lllv1t, lui!d·IOO, Sa, lliego, CA 92121 .-" ,■.:,
White Construction Inc.
Nancy Young
2524 Gateway Road
Carlsbad, CA 92009
Date Collected: 9/7/202 I
Date Received: 9/7/2021
Date Analyzed: 9/8/2021
Date Reported: 9/8/2021
Lab/Client ID/Layer
878108-023
23
Total Asbestos
878108-024
24
Total Asbestos
878108-025
25
Total Asbestos
878108-026
26
Total Asbestos
878108-027
27
Total Asbestos
878108-028
28
Total Asbestos
Location
106 · Wall
None Detected
106 · Wall
None Detected
Kitchen -Wall
None Detected
Kitchen -Wall
None Detected
Kitchen -Wall
None Detected
Kitchen -Wall
None Detected
Report Number:
Project Number:
Project Name:
Project Location:
Collected By:
Claim Number:
PO Number:
878108
SDl50095
Capstone
1545 Faraday A venue Suite I 00
Carlsbad, CA 92008
Brennan Bales
Job #14867
Numberof Samples: 51
Material Description Color
4 Inch Cove Base Black
Mastic Yellow
4 Inch Cove Base Black
Mastic Yellow
4 Inch Cove Base Black
Mastic Yellow
Composition ( % )
100% Non-
Fibrous Material
100% Non-
Fibrous Material
l00%Non-
Fibrous Material
100% Non-
Fi bro us Material
l00%Non-
Fibrous Material
l00%Non-
Fibrous Material
Page 6 of 10
Certificate of Analysis
PLM Asbestos Identification lel·BSIMiMlll
lree · RIH8Mll1
SIJl,Jb(~patriolt.ib.com n A I •• -~T LAB
6640 llllk Blvd., lulteA·IOO, Saollie<Jo, (A 9Z!ZI .-"' ,.~
White Construction Inc.
Nancy Young
2524 Gateway Road
Carlsbad, CA 92009
Date Collected: 9/7/2021
Date Received: 9n/2021
Date Analyzed: 9/8/2021
Date Reported: 9/8/2021
Lab/Client JD/Layer Location
878108-029 Kitchen. Wall
29
Total Asbestos None Detected
878108-030 Kitchen• Wall
30
Total Asbestos None Detected
878108-031 Kitchen -Floor
31
Total Asbestos None Detected
878108-032 Kitchen -Floor
32
Total Asbestos None Detected
878108-033 Kitchen • Floor
33
Total Asbestos None Detected
878108-034 Kitchen -Floor
34
Total Asbestos None Detected
Report Number: 878108
Project Number: SD I 50095
Project Name: Capstone
Project Location: 1545 Faraday Avenue Suite 100
Carlsbad, CA 92008
Collected By: Brennan Bales
Claim Number: Job #14867
PO Number:
Number of Samples: 51
Material Description
4 Inch Cove Base
Mastic
12x12 Vinyl Floor
Tile
Mastic
12x12 Vinyl Floor
Tile
Mastic
Color
Black
Yellow
Black
Grey
Black
Grey
Composition ( % )
100% Non·
Fibrous Material
100% Non·
Fibrous Material
100% Non-
Fibrous Material
100% Non-
Fibrous Material
100%Non-
Fibrous Material
100% Non·
Fibrous Material
Page 7 of 10
Certificate of Analysis
PLM Asbestos Identification tel -853-654-1221
tree -8l3-l81-Sl21
SIJ!al>&patriollab.rnm DA•· •--~T LAB
i640 lusUlvd., SulteA-100, San Di'90, C~ 9lll1 .-'"' '-■.:,
White Construction Inc.
Nancy Young
2524 Gateway Road
Carlsbad, CA 92009
Date Collected: 9/7/2021
Date Received: 9/7/2021
Date Analyzed: 9/8/2021
Date Reported: 9/8/2021
Report Number: 878108
Project Number: SD 150095
Project Name: Capstone
Project Location: 1545 Faraday Avenue Suite JOO
Carlsbad, CA 92008
Collected By: Brennan Bales
Claim Number: Job #14867
PO Number:
Number of Samples: 51
Lab/Client ID/Layer Location Material Description Color Composition ( % )
878108-035
35
Total Asbestos
878108-036
36
Total Asbestos
878108-037
37
Total Asbestos
878108-038
38
Total Asbestos
878108-039
39
Total Asbestos
878108-040
40
Total Asbestos
Kitchen -Floor
None Detected
Kitchen -Floor
None Detected
111 -Floor
None Detected
I 13 -Floor
None Detected
Conference Room -Floor
None Detected
Conference Room -Floor
None Detected
12x12 Vinyl Floor
Tile
Mastic
Carpet Tile Mastic
Carpet Tile Mastic
Carpet Ti le Mastic
Carpet Tile Mastic
Black
Grey
Grey
Grey
Grey
Grey
100% Non-
Fibrous Material
100% Non-
Fibrous Material
100%Non-
Fibrous Material
JOO% Non-
Fibrous Material
100% Non-
Fibrous Material
100%Non-
Fibrous Material
Page 8 of IO
Certificate of Analysis
PLM Asbestos Identification 1e1 • SS8·oiM1l1
free· 8lH8M1l1
SD!ab(~pa!riotlab.com n A I •• Si~T LAB
66-40 lusk 81vd., Sui!< A·IOO, Sao Die<JO, C~ 91111 ■-"" , • .:,
White Construction Inc.
Nancy Young
2524 Gateway Road
Carlsbad, CA 92009
Date Collected: 9/7/2021
Date Received: 9/7/2021
Date Analyzed: 9/8/2021
Date Reported: 9/8/2021
Lab/Client ID/Layer Location
878108·041 0.0. · Floor
41
Total Asbestos None Detected
878108·042 0.0. · Floor
42
Total Asbestos None Detected
878108·043 0.0. · Floor
43
Total Asbestos None Detected
878108·044 Reception -Floor
44
Total Asbestos None Detected
878I08•045 Reception -Floor
45
Total Asbestos None Detected
878I08·046 Hallway • Floor
46
Total Asbestos None Detected
Report Number:
Project Number:
Project Name:
Project Location:
Collected By:
Claim Number:
PO Number:
878I08
SD150095
Capstone
1545 Faraday Avenue Suite JOO
Carlsbad, CA 92008
Brennan Bales
Job #14867
Number of Samples: 51
Material Description Color Composition ( % )
Carpet Tile Mastic
Carpet Tile Mastic
Carpet Tile Mastic
Bamboo Flooring
Adhesive
Bamboo Flooring
Adhesive
Bamboo Flooring
Adhesive
Grey
Grey
Grey
Yellow
Yellow
Yellow
100% Non-
Fibrous Material
100% Non-
Fibrous Material
100% Non-
Fibrous Material
100% Non•
Fibrous Material
100% Non-
Fibrous Material
100% Non-
Fibrous Material
Page 9 or JO
Certificate of Analysis
PLM Asbestos Identification
White Construction Inc.
Nancy Young
2524 Gateway Road
Carlsbad, CA 92009
Date Collected: 9/7/2021
Dare Received: 9/7/2021
Date Analyzed: 9/8/2021
Date Reported: 9/8/2021
Lab/Client ID/Layer Location
!ti·8,8-6S4·Slll
lree·8ll·l8Mm
SDL.lba,patrioll•b.com nA· •• ..H~T LAB ~o LIISI< lllvd., lurte A·100, san Dil!90, c~ 91121 1-.r,L '-1.:,,
Report Number:
Project Number:
Project Name:
878108
SDI50095
Capstone
Project Location: 1545 Faraday Avenue Suite 100
Carlsbad, CA 92008
Collected By: Brennan Bales
Claim Number: Job #14867
PO Number:
Number of Samples: 51
Material Description Color Composition ( % )
Charlene Kingston -Analyst Michelle Lavallee• Approved By
Bulk sample(s) submitted was (were) analyzed in accordance with the procedure outlined in the US Federal Register 40 CFR 763, Subpart F, Appendix
A; EPA-600/R-93/i 16 (Method for Determination of Asbestos in Building Materials), and EPA-600/M4-82-020 (US EPA Interim Method for the
Determination of Asbestos in Bulk Insulation Samples). Samples were analyzed using Calibrated Visual Estimations (CVES); therefore, results may not be
reliable for samples of low asbestos concentration levels. Samples of wall systems containing discrete and separable layers are analyzed separately and
reported as composite unless specifically requested by the customer to report analytical results for individual layers. This report applies only to the items
tested. Resulb are representative of the samples submitted and may not represent the entire material from which the samples were collected. "None
Detected" means that no asbestos was observed in the sample. "<I%'" (less than one percent) or Trace means that asbestos was observed in the sample but
the concentration is below the quantiriable level of I%. This report was issued by a NIST/NVLAP (Lab Code 200982-0) and CADOHS-ELAP (Cert. No.
2805) accredited laboratory and may not be reproduced, except in full without the expressed written consent of Patriot Environmental Laboratory
Services, Inc. This report may not be u~ed to claim product certifo.:.ition, approval or endorsement by NIST, NVLAP, ELAP or any government agency.
ASB_Rep_8.14
Page JO of 10
Lab Use Only: g1 ~ l O ~
Turn Arou~ ,:ime:
( ) ERS N._24 HRS
( ) 48 HRS ( ) 72 HRS
lei -858-677-8900
free-855-181-4512
fax -858·617-9009
Patriotlab.com
6640 Lusk Blvd., Suile A-100, San Diego, (A 92121 PAmalr
Environmental Laboratory Services, Inc.
ASBESTOS FIELD BULK SAMPLE COC
Project Name: {--, + I Pro~ct #; _... . __ j Office Use Only:
r>-/$ c,/\.t__ 4t'--i/ ,-.....,C,C,,cn D MH
Project Address: I ~~ .J ~ 5 F~r:~ A~ City:c_,~.,. /sU Zip?2~ 8
Sample
ID
Sample Location Material Type F NF Condition Notes
J I. c~
~3~'-'-+--~------¼---+----+----+-+--l----,f-+--+----½----j'~
t--5.-=--~ -+-'-I ~~~---r---------i------;-------~f-----+--------1---------+------4.[1
~l \~ . u
~.,~ I~ ,II' V \LI ~ ,v R
1-\--'--'-\--+0-=-r-----. (:)_. ------,-l----+---'-""'--'-A--'---"\l_,_\ ~=--:..,__.:.__r...._+-+++---+-+-------------f--------j~
\'2--. w " '
IC'.:in ..c,
\C'L
\5 ------~f---7----------j ' :.,,,-1
.... \.V
\r '
Sampled/Relinauished Bv: SiQn:
Samples Received By: Sign: Date: • 4 -''1 Time: ,
Pag ..__, or-.""'✓---'
V
Bulk Sample COC Rev 12.27.2017
Lab Use Only:
Turn Around Time:
( ) ERS ( ) 24 HRS
( ) 48 HRS ( ) 72 HRS
lel-858-677-8900
tree-855-787-4521
fax -858-677-9009
Palriotlab.rnm ·
6640 Lusk Blvd., 5uile A-IOO, San Diego, (A 9llll PAm.lt-
1 Environmental Laboratory Services, Inc.
ASBESTOS FIELD BULK SAMPLE COC
Project Name: I Projec~ o)'XJ<Jtf S, I ~:.!1se Only:
Project Address: City: Zip:
Sample Sample Location Material Type F NF Condition Notes
ID
'l.5,2' l~ltd,e"' -WAH 4 ',:.. ls 1,U\ w/ ,A) o..f+Jc Cov..w11.. X (3.___} ~-A
'2'1,Z.I
2q,3o \ ,_ ,,,
V '1 VJ ' :_;
s1,~, ,--. 1:Z..l<l"2-,· i3lt.c.l<'. A Jt' I 2Cfj-s-J4 ~ \-'" \oor VF--r-wl 4.f C
--I ' '3'!>,~ . ··-v-~--~--~ 36,3-G V ' ~ \Y ' V
37 111 -f:r~e. M_as+lc_ 5,A. fl •
1!. ll~
3\ ~,..ft--
4b 1 ~ --~ --~ --~·~--~
"1 \ ()•0. -
~z • ,/
..q3, \Y \ / \ I/ \Y \ i/ '" A4 (le.~ ~"'~~~le ~;;:. ... (';
~S, ~ I
-
,t\(Q \-\~\\~,, 'V' \ I/ ~ ' V ' ii
-~,
Samoled/Relinnuished Bv: Sian: ~-------~~ Date: --i 1 ~ 'vJ Time:
Samoles Received Bv: Sign: I \ Date: IA I I II'\ I Time:
Pagl. ""' ........ -, I • I -J
Bulk Sample COG Rev 12.27.2017
Project Name:
Project Address:
tel -858-677-8900
free-855-787-4521
fax -858-677-!009
Palrlollab.oom
6640 lusk Blvd., Suite A-100, San Diego, CA 91111
SAMPLE LOCATION DIAGRAM
PA-rmlr Environmental Laboratory Services, Inc.
Project#:$/ 50 of5
Loss Type: □ Fire D Water eno D Demo (During/ Upcoming) (Full/ Limited Survey)
D Vehicle lmpac 'Sewage □ Confirm Suspect ACM D Other (Specify): ---~-
Foundation: Building Type: Level: Frame:
□Baised □SF Residential D School Q.:lingle Story D Wood
~ement Slab ommercial D Mobile Home )"'.!Two Story D Brick
D Both □MF Residential D Church D Multi -Story i:7Metal
# of Un its "I'S Cinder Block
Sample Location Dia Date:
INTE.RWESl
DATE: 10/15/2021
JURISDICTION: City of Carlsbad
PLAN CHECK#.: CBC2021-0319.Rcl
PROJECT ADDRESS: 1545 Faraday Ave
PROJECT NAME: Capstone HQ-TI
SET II
□ APPLICANT
□ JURIS.
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The check list transmitted herewith is for your information. The plans are being held at lnterwest
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
~ lnterwest staff did not advise the applicant that the plan check has been completed.
D lnterwest staff did advise the applicant that the plan check has been completed.
Person contacted: Nancy Telephone#: 760-931-1130
Date contacted: (by: ) Email: nancy@whiteconstructioninc.com
Mail Telephone Fax In Person
0 REMARKS:
By: Ali Doudar for Erich Kuchar
lnterwest
10/06/2021
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
, .
• 1W
I NTERWEST
DATE: 9-14-2021
JURISDICTION: Carlsbad
PLAN CHECK#.: CBC2021-0319
PROJECT ADDRESS: 1545 Faraday Ave
PROJECT NAME: Capstone HQ-Tl
SET: I
lffl'~tt,ED
OCT O O Z02f
CITY OF CARLSBAD
BUILDING DIVISION
0 The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
0 The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
IZ! The check list transmitted herewith is for your information. The plans are being held at lnterwest
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
0 The applicant's copy of the check list has been sent to:
D lnterwest staff did not advise the applicant that the plan check has been completed.
IZ! lnterwest staff did advise the applicant that the plan check has been completed .
Person contacted: Nancy Telephone#: 760-931-1130
Date contacted: (by: ) Email: nancy@whiteconstructioninc.com
Mail Telephone Fax In Person
0 REMARKS:
By: Erich A. Kuchar, P .E.
lnterwest
8-31-2021
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, Californ ia 92 123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
/ PLAN REVIEW CORRECTION LIST
COMMERCIAL
PLAN CHECK#.: CBC2021-0319
OCCUPANCY: B
TYPE OF CONSTRUCTION: V-B
SPRINKLERS?: Yes
DA TE PLANS RECEIVED BY
JURISDICTION: 8-25-2021
DATE INITIAL PLAN REVIEW
COMPLETED: 9 -14-2021
FOREWORD (PLEASE READ):
JURISDICTION: Carlsbad
USE: Offices
ACTUAL AREA: 5,938 sqft
STORIES: 1 + Mezz.
HEIGHT: -
OCCUPANT LOAD: 142
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 8-31 -2021
PLAN REVIEWER: Erich A. Kuchar, P.E.
I ._
This plan review is limited to the technical requirements contained in the California version of
the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy conservation, noise attenuation and access for
the disabled. This plan review is based on regulations enforced by the Building Department.
You may have other corrections based on laws and ordinances enforced by the Planning
Department, Engineering Department, Fire Department or other departments. Clearance from
those departments may be required prior to the issuance of a building permit.
Code sections cited are based on the 2019 CBC, which adopts the 2018 IBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2018 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
. .
Sheet G4.0
revised site
plan and
accessible
details
GENERAL
1. Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to lnterwest and the Carlsbad Planning,
Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to lnterwest, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad
Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to lnterwest only will not be reviewed by
the City Planning, Engineering and Fire Departments until review by lnterwest is
complete.
2. Plans may be submitted in electronic format, subject to the jurisdiction's
approval. If so, they must have restrictions removed from the security settings.
Electronic plans with restrictions to markups, printing, or stamping will not be
approved.
3. A reminder that due to Covid-19, the City will not permit counter corrections.
Please make sure all the items are satisfied; otherwise, another round of
corrections will be necessary.
4. All plan sheets must be signed by designers.
•
DISABLED ACCESS REVIEW LIST
DEPARTMENT OF STATE ARCHITECT-TITLE 24
The following disabled access items are taken from the 2019 edition of California Building
Code, Title 24. Per Section 1.9.1, all publicly and privately funded public accommodations
and commercial facilities shall be accessible to persons with disabilities.
5.
REMODELS, ADDITIONS AND REPAIRS
When alterations, structural repairs or additions are made to an existing building,
that building, or portion of the building affected, is required to comply with all of the
following requirements, per Section 11 B-202.4:
• T he area of specific alteration, repair or addition must comply as "new"
construction.
Sheet G4.0
• A primary entrance to the building and the primary path of travel to the
altered area, must be shown to comply with all accessibility features.
• The path of travel shall include the existing parking.
curb ramp -• Existing toilet and bathing facilities that serve the remodeled area must be
shown to comply with all accessibility features. detail #6
CURB RAMPS
\I
6. Detectable warnings shall be installed in curb ramps with one or two entrance/
exit points that are 6' or 9' wide, respectively. Section 11-8-705.1.2.2. See
Exceptions. For existing structures, the non-truncated domes may be 24" deep
instead of 36" deep meaning you must maintain a 5'-0" accessible walkway at
curb ramps. 36" deep truncated dome and 24" deep non-truncated dome. Show
these dimensions on sheet G4.0 and if sidewalk needs to be widened show how
this will be accomplished.
..
•
Sheet ID5.1
existing
restroom
plans and
elevations
provided
Sheet G3.0.
revised to
remove A.2
reference
Sheet G3.0.
revised
urinal detail
Sheet G3.0.
revised
water closet
detail. also
see ID5.1,
elevations
-
-v
7.
8.
9.
10.
11.
SANITARY FACILITIES
Provide an enlarged plan view of the existing three bathrooms fully dimensioned
and with as-built elevations not just generic details as shown on sheet G3.0
Provide sheet A.2 as referenced on the toilet elevation.
RESTROOM FIXTURES AND ACCESSORIES
Show, or note, on the plans that accessible urinals meet the following
requirements, per Section 11 B-605:
a) The rim of at least one urinal shall:
i) Project at least 13½ " from the wall.
The toilet paper dispenser shall be 7"-9" from edge of toilet not 12". Update.
Sheet G3.0. , ~
revised
The combination toilet paper dispenser, as shown on plans, is not acceptable. The
1-½" clearance between the grab-bar and the wall is absolute, not subject to
construction tolerances to encroach into, as the dispenser will. This is a new
change effective July 1, 2018 in the CBC, Sec. 11 B-609.3. Update and show new
locations below the grab bar.
detail with ~
combo
dispenser 12. Remove all shower details as there is no shower.
Sheet G3.0. '11
removed
accessible ~
ADDITIONAL
shower
detail
13. MEP and Structural have no comments.
14. Please provide a response list indicating where each correction item has been
addressed on the plans. I.e., specify the plan sheet, note, or detail number,
calculation page, etc., where the item is corrected on the plans.
15. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans. Have changes been
made to the plans not resulting from this correction list?
Please indicate: □ Yes □ No
16. The jurisdiction has contracted with lnterwest, located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Erich A. Kuchar,
P.E. at lnterwest. Thank you.
• 1W
INTERWEST
A SAl'£b4JHI t;OMPAHV
DATE: 9-14-2021
JURISDICTION: Carlsbad
PLAN CHECK#.: CBC2021-0319
PROJECT ADDRESS: 1545 Faraday Ave
PROJECT NAME: Capstone HQ-TI
SET: I
□ APPLICANT
□ JURIS.
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
~ The check list transmitted herewith is for your information. The plans are being held at lnterwest
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
D lnterwest staff did not advise the applicant that the plan check has been completed.
~ lnterwest staff did advise the applicant that the plan check has been completed.
Person contacted: Nancy Telephone#: 760-931-1130
Date contacted: .(by: ) Email: nancy@whiteconstructioninc.com
Mail Telephone1 Fax In Person
0 REMARKS:
By: Erich A. Kuchar, P.E.
lnterwest
8-31-2021
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
PLAN REVIEW CORRECTION LIST
COMMERCIAL
PLAN CHECK#.: CBC2021-0319
OCCUPANCY: B
TYPE OF CONSTRUCTION: V-B
SPRINKLERS?: Yes
DATE PLANS RECEIVED BY
JURISDICTION: 8-25-2021
DATE INITIAL PLAN REVIEW
COMPLETED: 9-14-2021
FOREWORD (PLEASE READ):
JURISDICTION: Carlsbad
USE: Offices
ACTUAL AREA: 5,938 sqft
STORIES: 1 + Mezz.
HEIGHT: -
OCCUPANT LOAD: 142
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 8-31-2021
PLAN REVIEWER: Erich A. Kuchar, P.E.
This plan review is limited to the technical requirements contained in the California version of
the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy conservation, noise attenuation and access for
the disabled. This plan review is based on regulations enforced by the Building Department.
You may have other corrections based on laws and ordinances enforced by the Planning
Department, Engineering Department, Fire Department or other departments. Clearance from
those departments may be required prior to the issuance of a building permit.
Code sections cited are based on the 2019 CBC, which adopts the 2018 IBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulatiorts. Per Sec. 105.4 of
the 2018 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
,
GENERAL
1. Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to lnterwest and the Carlsbad Planning,
Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to lnterwest, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad
Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to lnterwest only will not be reviewed by
the City Planning, Engineering and Fire Departments until review by lnterwest is
complete.
2. Plans may be submitted in electronic format, subject to the jurisdiction's
approval. If so, they must have restrictions removed from the security settings.
Electronic plans with restrictions to markups, printing , or stamping will not be
approved.
3. A reminder that due to Covid-19, the City will not permit counter corrections.
Please make sure all the items are satisfied; otherwise, another round of
corrections will be necessary.
4. All plan sheets must be signed by designers.
DISABLED ACCESS REVIEW LIST
DEPARTMENT OF STATE ARCHITECT-TITLE 24
The following disabled access items are taken from the 2019 edition of California Building
Code, Title 24. Per Section 1.9.1, all publicly and privately funded public accommodations
and commercial facilities shall be accessible to persons with disabilities.
REMODELS, ADDITIONS AND REPAIRS
5. When 'alterations, structural repairs or additions are made to an existing building,
that building, or portion of the building affected, is required to comply with all of the
following requirements, per Section 11 B-202.4:
• The area of specific alteration, repair or addition must comply as "new"
comstruction.
• A primary entrance to the building and the primary path of travel to the
altered area, must be shown to comply with all accessibility features.
• The path of travel shall include the existing parking.
• Existing toilet and bathing facilities that serve the remodeled area must be
shown to comply with all accessibility features.
CURB RAMPS
6. Detectable warnings shall be installed in curb ramps with one or two entrance/
exit points that are 6' or 9' wide, respectively. Section 11 -B-705.1.2.2. See
Exceptions. For existing structures, the non-truncated domes may be 24" deep
instead of 36" deep meaning you must maintain a 5'-0" accessible walkway at
curb ramps. 36" deep truncated dome and 24" deep non-truncated dome. Show
these dimensions on sheet G4.0 and if sidewalk needs to be widened show how
this will be accomplished.
• •
SANITARY FACILITIES
7. Provide an enlarged plan view of the existing three bathrooms fully dimensioned
and with as-built elevations not just generic details as shown on sheet G3.0
8. Provide sheet A.2 as referenced on the toilet elevation.
RESTROOM FIXTURES AND ACCESSORIES
9. Show, or note, on the plans that accessible urinals meet the following
requirements, per Section 11 B-605:
a) The rim of at least one urinal shall:
i) Project at least 13½" from the wall.
10. The toilet paper dispenser shall be 7"-9" from edge of toilet not 12". Update.
11. The combination toilet paper dispenser, as shown on plans, is not acceptable. The
1-½" clearance between the grab-bar and the wall is absolute, not subject to
construction tolerances to encroach into, as the dispenser will. This is a new
change effective July 1, 2018 in the CBC, Sec. 11 B-609.3. Update and show new
locations below the grab bar.
12. Remove all shower details as there is no shower.
ADDITIONAL
13. MEP and Structural have no comments.
14. Please provide a response list indicating where each correction item has been
addressed on the plans. I.e., specify the plan sheet, note, or detail number,
calculation page, etc., where the item is corrected on the plans.
15. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans. Have changes been
made to the plans not resulting from this correction list?
Please indicate: □ Yes □ No
16. The jurisdiction has contracted with lnterwest, located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Erich A. Kuchar,
P. E. at lnterwest. Thank you.
. '
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Erich A. Kuchar, P.E.
BUILDING ADDRESS: 1545 Faraday Ave
BUILDING OCCUPANCY: B
BUILDING AREA Valuation
PORTION (Sq.Ft.) ~ier
Tl 5938 46.51
Air Condilioring
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
ii I 1997 UBC Bu ding P<r mit fee ...
I ,".I ,,·I:
] 1997 USC Pfan Check Fee .:!'.1 1 ·,,.·,1 :::i:
Type of Review: r,; Complete Review
r Repetitive Fee r Other .. r-..-! Repeats r HolA'ly
EsGilFee
r r
Reg.
Mod.
PLAN CHECK#.: CBC2021-0319
DATE: 9-14-2021
VALUE ($)
276,176
276,176
1
)
r Structural Only
]Hr.@*
$815.37)
Sheet 1 of 1
PCSD Engineering Corp
3529 Coastview Court
Carlsbad, CA 92010
Ph: 760·207 1885
Structural Design Calculations
Tenant Improvement
Client
White Construction
2524 Gateway Road
Carlsbad. CA 92009
Proiect
August 13, 2021
PCSD File#: 21-424.1
~~~. ,,..✓
'"' 1.-,.
r•,\1,! ,'i\,,,t,•;i,<'01 ~A-•• r,,,.,,a
.;.H,ll'1 ... t'1"1'1<l'
I
h
Paul Christenson San Diego Engineering
3529 Coastview Ct -Carlsbad, CA 92010
Telephone (760) 207-1885-Email: paul.pcsd@gmail.com
1.0 Design Criteria: Capstone HQ
21-424.1
Code:
Timber:
2019 California Building Code -ASCE 7-16
Douglas Fir-Larch (DF-L), WWPA or WCLIB
2x Wall Framing: DF-L #2 (unless noted otherwise)
2x Rafters & Joists: DF-L #2 " "
Posts & Beams: DF-L #1 •
Glue-Lam Beams: Simple Span: Grade 24F-V4 (DF/DF)
Grade 24F-V8 (DF/DF) Cantilevers:
Sheathing: Min. APA-Rated Sheathing, Exposure 1, Plywood or OSB (U.N.O.)
Engineered Framing Wood /-Joists: TJI 110,210,230,360,560 ICC ESR-1153
1.9E Microllam, 2.0E Parallam ICBO ER-4979
Concrete:
Concrete Block:
Mortar:
Grout:
LVL, PSL
Compressive Strength @ 28 days per ASTM C39-96:
Footings: f'c = 2500 psi
Grade Beams: f'c = 3000 psi
Grade N-I per ASTM C90-95, fm = 1500 psi per ASTM E447-92
Type S Mortar Cement per ASTM C270-95, Min. f'm = 1800 psi@ 28 days.
Coarse Grout w/ 3/8" Max. Aggregate per ASTM C476-91,
Min. fm = 2000 psi @ 28 days.
Reinforcing Steel: #4 & Larger:
#3 & Smaller:
ASTM A615-60 (Fy = 60 ksi)
ASTM A615-40 (Fy = 40 ksi)
Structural Steel: 'W' Shapes: ASTM A992, Fy= 50-65 ksi
Plates, Angles, Channels ASTM A36, Fy = 36 ksi
Tube Shapes: ASTM A500, Grade B, Fy= 46 ksi
Pipe Shapes: ASTM A53, Grade B, Fy=35 ksi
Welding Electrodes: Structural Steel: E70-T6
E90 Series
Bolts:
Soils:
References:
A615-60 Rebar:
Sill Plate Anchor Bolls & Threaded Rods:
Steel Moment & Braced Frames:
1500 psf Bearing Pressure
A307 Quality Minimum
A325 (Bearing, U.N.O.)
~ ,u/f;",t.r/ne.nJ'O.n ';/,m ~o
:&JV'een.nJ
JOB
SHEET NO
CALCULATED BY
CHECK BY
3529 Coastview Ct -Carlsbad, CA 9201 0 SCALE
Telephone (760) 207-1885 -Email: paul.pcsd@gmail.com
2.0 LOAD LIST
2.1 Roof <Vaulted)
Roofing
15/32" Sheathing
Roof Framing
5/8" Gyp. Bd.
Insulation and Misc.
IoL =
ILL=
Total Load=
2.2 Roof (w I ceiling)
Roofing
15/32" Sheathing
Roof Framing
Insulation and Misc.
2.3 Ceiling
Ceiling Joists
IoL =
ILL=
Total Load=
5/8" Gyp. Bd.
Insulation and Misc.
2.4 Walls
IoL =
ILL=
Total Load=
Exterior Wall
7 /8" Stucco
15/32" Sheathing
2x4 Studs @ 16" o.c.
5/8" Gypsum Bd.
Misc.
6.0 psf
2.0 psf
2.8 psf
2.8 psf
1.4 psf
15.0 psf
20.0 psf
35.0 psf
6.0 psf
2.0 psf
2.8 psf
l.2 psf
12.0 psf
20.0 psf
32.0 psf
1.3 psf
2.8 psf
l.9 psf
6.0 psf
10.0 psf
16.0 psf
9.0 psf
l.5 psf
I.I psf
2.8 psf
0.6 psf
15.0 psf
Interior Wall
1/2" Gyp. Bd. (2 Sides)
2x4 Studs@ 16" o.c.
Misc.
21-424.1
f,,.
PSC
4.6 psf
1.1 psf
2.3 psf
8.0 psf
OF
DATE
DATE
8/13/21
.?7,ru/"C,f'r/ne:11.n,:11 e/n, ~ ..
:&_pneermJ
3529 Coastview Ct -Carlsbad, CA 9201 0
JOB 21-424.1
~ OF PSC DAT_E_S,_/~13'"'12,-1~
DATE
SHEET NO
CALCULATED BY
CHECK BY
SCALE ---------
Telephone (760) 207-1885 -Email: paul.pcsd@gmail.com
2.0 LOAD LIST (CONTINl
2.5 Floor
Floor Cover
Sheathing
2x F.J.
5/8" Gyp. Bd.
Insulation and Misc.
loL =
ILL=
Total Load=
5.5 psf
2.3 psf
3.1 psf
2.8 psf
1.3 psf
15.0 psf
40.0 psf (60.0 psf -Decks)
55.0 psf
WIND PARAMETERS
2.6 Wind Basic Wind Speed = 110 mph Exposure Cat = B
Ps = >-.Kzt•l*Ps30
P= 26.6 psf
P = 16.0 psf
2.7 Seismic
Sos= 0.792
Sos
Cs= (R/1)
Cs= 0.198
USE:
V= 0.198 WoL
(ASCE 7-16 -Equation 28.5-1)
(*0.6 ASD)
(11.4.5)
ASD BASE SHEAR
VASD
VAfln= 0.141 WoL
>,. = 1.00 (fig. 28.5-1) Ps30= 26.6 psf
Kzt = 1.00 (fig. 26.8) I= 1.0
USGS APPLICATION
S, = 0.99 S1 = 0.361
F,= 1.20 F = ' 0.00
R= 4 I= 1.00
h, = 20.00
Occupancy Category: 2
Site Class: D
SEISMIC DESIGN CATEGORY
s. <0.75
S1 >o.04
Ss>o.1s
(11.6 ASCE 7-16)
(11.4.2 ASCE 7-16)
(fig. 28.5-1)
(table 1.5-2)
T, = C, • (l,,,J°-75 = 0.189
Ts = So/Sos-0
k= 1.0
~qn. 12.8-1 Not OJ
Ta<0.5
Seismic Design Category: D
MEMBER REPORT
Aoor Framing, (FB-1) Fir Bm
PASSED
1 plece(s) 3 1/2" x SI 1/2" 2.2E Parallam® PSL ~1
... .
0 0
All locations are measured from the outside face c:I left support ( or left cantilever end). All dimensions are hor1zontal. .. ' . :,~\~i ~;'i,~-~!#J, ~~--t . ' n, ·: ~;~~§J,
Member Reaction {lbs) 2764@2" 7656 (3. 50")
Shear (lbs) 1819@ 1' 1" 6428
Moment (Ft-lbs) 3928@ 3' 2" 13057
Uve Load Def!. (In) 0.039@3' 2" 0.200
Total Load Den. (In) 0.059@3' 2" 0.300
• Oellectlor, ~: LL (l/360) and Tl (l/2'40) .
• Allowed moment does not reflect the adjustment ror the beam stablAty factor.
lliiiii.ii' t.;.<W1~1:.z;m -.~.~}-. "· ;,•
Passed {36%) --
Passed {28%) 1.00
Passed (30%) 1.00
Passed (l/999+) --
Passed (l/999+) --
~~,,,,.,, . ~•'.;;\~t-~$~
1.0 D + 1.0 L (All Spans)
1.0 D + 1.0 L (All Spans)
1.0 D + 1.0 L (All Spans)
1.0 D + 1.0 L (All Spans)
1.0 D + 1.0 L (All Spans)
SY5leffl : Floor
Member Type : Drop Beam
Building Use : Residential
Building c.ode : !BC 2018
Design Methodology : ASD
• llloclclng Panels are assumed ID cany no loads applied directly abcM! them and the Ml load Is alll)lled II> the member being designed.
•Maximum allowable bracing lnlZfvals based on applied load.
1 • Uniform (PSF)
Weyemaeuser ~nts !hat the sizing of Its products wiN be In aa::ordance wtth Weyerhaeuser product design critiena and published design value. Weyerhaeuser e,cpressly disclaims any other w.r111t1es
~ to the software. Use of this software Is not lnbendtd to drcun,,;ent the need for a desq, pro!Mslonal as deliennined by the authonty having Jurisdiction. The designer of record, builder or framer Is
responsible ID assure !hat this calculation ts compeUble wtth the overall project. Accessories (Rim Boerd, Blocking Panels and Squash Blocks) are not de5lgned by this softwate. Products manufactured at
W~ fadllties are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluab!d by ICC-ES under evaluation reports ESR-1153 and ESR-1387
r,d/or tested In aax,rdance wllh appllcable ASTM standards. !'or current axle evaluation reports, Weyerhaeuser proc!uct •~re and instalatlon oetans refer to
www.~ser.mm/woodproci.m/document-Ntn,y.
The product a,lllllcatlon, Input design iollds, dimensions and support Information have Ileen provided by ForteWEB Software C)peratcr
Paul Ov1sten5on
PCSO fngl,-ing
(760) 207-1885
paul.pc:sdOomall .(X)lll
JobNotlll
A
Weyerhaeuser
10/20/2021 6:27:04 PM UTC
ForteWEB v3.2, Engine: VB.2.0.17, Data: VB.1.0.16
File Name: capstone
Paael /1
PCSD Engineering Corp
3529 Coastview Court
Carlsbad, CA 92010
Ph: 760-207-1885
-c.
0~ '1W.J.. ., .: 1~6•'
a,....,c,,1,.((,f,.'h• lZr,11,t"n.u, 1.:~,.
"01"' "11•-> WDuf> --
Job#: 1 \· 4 ·1.'f
Page: C of __ , ___ _
Date: _________ _
Engineer: _______ _
,?,u/"{;,tn'.d,n,o,t ;f,,, ~o
:&yn#NIJ
3529 Coastview Ct -Carlsbad, CA 92010
Telephone (760) 207-1885-Email: paul.pcsd@ mail.com
6.0 FOUNDATION DESIGN
6.1 CONTINUOUS FOOTING
w = 1125 plf
width = ~ plf
1500 psf
0.75 ft (MIN.) => 9 INCHES (MlN.)
( E) 15 "WIDE CONTIN. FTG W/
l -# 4 TOP AND BOTTOM & EMBED.
18 "INTO UNDISTURBED SOIL (MIN.)
6.2 MAX POINT LOAD ON FOOTING
JOB 21-424.1
SHEET NO t, OF _ _,b __ _
CA LC ULA TED BY PSC DATE 8/13/21
CHECKBY ____ DATE __ _
SCALE
ASBP = 1500 psf
Pa11= 1500 • ~ • ~
12 12
P a11 = 7500 lbs
I. I I
OFFICE USE ONLY SAN DIEGO REGIONAL
HAZARDOUS MATERIALS
QUESTIONNAIRE
RECORD ID # ___________________ 1 PLAN CHECK # __________________
1
usiness Name
CWHQ Carlsbad, LLC c/o Capstone Advisors
Project Address (include suite)
1545 Farada Ave Suite 100
Mailing Address (include suite)
1545 Farada Ave Suite 100
Project Contact
Chad Johnston
Business Contact
Chad Johnston
Telephone#
(760) 827-6010
City State Zip Code
Carlsbad CA 92008
City State Zip Code
Carlsbad CA 92008
Applicant E-mail Telephone#
·ohnston capstoneadvisors.com (760) 827-6010
BP DATE
APN#
212-130-29-00
Plan File#
CBC2021-0319
The following questions represent the facility's activities, NOT the specific project description.
I
PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: (not required for projects within the City of San
Diego): Indicate by circling the item. whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal.
Occupancy Rating: B (Office) Facility's Square Footage (including proposed project): 5,938
1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives
2. Compressed Gases 6. Oxidizers 10. Cryogenics
3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials
4. Flammable Solids 8. Unstable Reactives 12. Radioactives
13. Corrosives
14. Other Health Hazards
j15. None of I hese. I
PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION (HMO): If the answer to any of the
questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Avenue, Suite 170, San Diego, CA 92123.
Call (858) 505-6700 prior to the issuance of a building permit.
FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy: 0 CalARP Exempt
YES NO (for new construction or remodeling projects) I 0 IX) Is your business listed on the reverse side of this form? (check all that apply). Date Initials 1.
2.
3.
4.
5.
6.
7.
8.
0 IX) Will your business dispose of Hazardous Substances or Medical Waste in any amount?
D IX) Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500
D
D
D D D
pounds and/or 200 cubic feet?
IX) Will your business store or handle carcinogens/reproductive toxins in any quantity?
IX) Will your business use an existing or install an underground storage tank?
IX) Will your business store or handle Regulated Substances (CalARP)? IZI Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)?
IX) Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to
or greater than 1.320 gallons? (California's Aboveground Petroleum Storage Act).
0 CalARP Required
I
Date Initials
0 CalARP Complete
I
Date Initials
PART 111: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCD): The following questions are intended to identify the majority of air pollution
issues at the planning stage. Your project may require additional measures not identified by these questions. Some residential projects may be exempt from APCD
requirements. If yes is answered for either questions 1, 2 or 5 or for more comprehensive requirements, please contact APCD at apcdcomp@sdcounty.ca.gov;
(858) 586-2650; or 10124 Old Grove Road, San Diego, CA 92131.
YES NO
1. ~ 0 Will the project disturb 100 square feet or more of existing building materials?
2. 0 [2S] Will any load supporting structural members be removed?
3. ~ 0 (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by an individual that has passed an EPA-approved
building inspector course?
4. D lig (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Based on the survey results, will the project disturb any asbestos containing material? If yes, a
notification may be required at least 10 working days prior to commencing asbestos removal. Additionally, a notification may be required prior to
the removal of a load supporting structural member(s) regardless of the presence of asbestos.
5. D ~ Will the project or associated construction equipment emit air contaminants? See the reverse side of this form for typical equipment requiring an
APCD permit. If yes, contact APCD prior to the issuance of a building permit.
6. 0 0 (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school
bounda ?
Briefly describe business activities: Briefly describe proposed project:
Real estate office Existing interior office Tl
I declare under penalty of perjury that to the best of my knowledge and bet
Nancy Young, PM 09 I 30 / 21
Name of Owner or Authorized Agent Date
FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: _________________________________ _
BY· DATE· I I
EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY
COUNTY-HMO· APCD COUNTY-HMO APCD COUNTY-HMO APCD
~~'-\.on Co,,~
<:.;:; o.,...
.... Rt:-v1ewed <2 < 09/30/2021-MF C
t'n:t."i101tti:JIS
s ~,:, ,,., ,i; ),ego c,o
•A stamp in this box only exempts businesses from completing or updating a Hazardous Matenals Business Plan. Other perm,tt,ng requirements may still apply
HM-9171 (9/18) County of San Diego -DEH -Hazardous Materials Division
DocuSign Envelope ID: C4B35f6C-529f-4385-B862-3DDAD94ff85C
ENCINA WASTEWATER AUTHORITY
INDUSTRIAL WASTEWATER DISCHARGE PERMIT
SCREENING SURVEY
6200 Avenida Encinas, Carlsbad, CA 92011
Phone: 760-438-3941 Fax: 760-476-9852
SourceControl@encinajpa.com
Date: 8/31/2021
Business Name: CWHQ Carlsbad, LLC c/o Capstone Advisors
Street Address: 1545 Faraday Avenue
Email Address: johnston@capstoneadvisors.com
PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) [K]
Check all below that are present at your facility:
o Acid Cleaning
o Assembly
o Automotive Repair
o Battery Manufacturing
o Biofuel Manufacturing
o Biotech Laboratory
o Bulk Chemical Storage
o Car Wash
o Chemical Manufacturing
o Chemical Purification
o Dental Offices
• Dental Schools
• Dental Clinics
o Dry Cleaning
o Electrical Component
Manufacturing
o Fertilizer Manufacturing
o Film/X-ray Processing
o Food Processing
o Glass Manufacturing
o Industrial Laundry
o Ink Manufacturing
o Laboratory
o Machining/Milling
o Membrane manufacturing
(i.e. water filter membranes)
o Metal Casting/Forming
o Metal Fabrication
o Metal Finishing
• Electroplating
• Electroless Plating
• Anodizing
• Coating (i.e. phosphating)
• Chemical Etching/Milling
• Printed Circuit Board
Manufacturing
o Metal Powders Forming
o Nutritional Supplement/Vitamin
Manufacturing
o Painting/Finishing
o Paint Manufacturing
o Personal Care Products
Manufacturing
o Pesticide Manufacturing/ Packaging
o Pharmaceutical Manufacturing
(including precursors)
o Porcelain Enameling
o Power Generation
o Print Shop
o Research and Development
o Rubber Manufacturing
o Semiconductor Manufacturing
o Soap/Detergent Manufacturing
o Waste Treatment/Storage
New Business? Yes O No O SIC Code(s) if known: _____ _ Date operation began/will begin: ______ _
Tenant Improvement? Yes O NoO If yes, briefly describe improvement: _________________ _
Description of operations generating wastewater (discharged to sewer, hauled or evaporated): __________ _
Estimated volume of industrial wastewaterto be discharged (gal/ day): __________________ _
List hazardous wastes generated (type/volume): __________________________ _
Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? Yes D Date: ____ No 0
Pagelof2
DocuSign Envelope ID: C4B35F6C-529F-4385-B862-3DDAD94FF85C
ENCINA WASTEWATER AUTHORITY
INDUSTRIAL WASTEWATER DISCHARGE PERMIT
SCREENING SURVEY
6200 Avenida Encinas, Carlsbad, CA 92011
Phone: 760-438-3941 Fax: 760-476-9852
SourceControl@encinajpa.com
The commercial enterprises listed below are a partial listing of businesses that are exempt from industrial wastewater
discharge permitting under normal operating conditions. They are exempt because (a) they discharge no process wastewater
(i.e., they only discharge sanitary wastewater with no pollutants exceeding any local limits), and (b) they have no potential to
negatively impact the EWPCF or other wastewater treatment plants in the ESS. Any questions regarding exemptions
should be referred to EWA Source Control staff.
o Automobile Detailers o Hotels/Motels (no laundry)
o Barber /Beauty Shops o Laundromats
o Business/Sales Offices o Libraries
o Cleaning Services o Medical Offices (no x-ray developing)
o Carpet/Upholstery o Mortuaries
o Childcare Facilities o Museums
o Churches o Nail Salons
o Community Centers o Nursing Homes
o Consulting Services / o Office Buildings (no process flow)
o Contractors o Optical Services
o Counseling Services o Pest Control Services (no pesticide repackaging for sale)
o Educational Services (no auto repair/film developing) o Pet Boarding/Grooming Facilities
o Financial Institutions/Services o Postal Services (no car wash/auto repair)
o Fitness Centers o Public Storage Facilities
o Gas Stations (no car wash/auto repair) o Restaurants/Bars
o Grocery Stores (no film developing) o Retail/Wholesale Stores (no auto repair/film developing)
o Residential based Businesses o Theaters (Movie/Live)
CERTIFICATION STATEMENT
I certify that the information above is true and correct to the best af my knowledge.
DocuSigned by:
Signatu r ~"' 2°~11, Print Name: ___________ _ Chad Johnston DATE: 8/31/2021
303897D1C591482
Facility Contact: ___________ _ Title: ---------------
ENCi NA WASTEWATER AUTHORITY
6200 AVENIDA ENCINAS, CARLSBAD, CA Phone: 760-438-3941 Fax: 760-476-9852
SourceControl@encinajpa.com
Page 2 of 2
DocuSig n Envelope ID: 258682E6-4003-4411-AA6C-B88803A851 DE
(city of
Carlsbad
CLIMATE ACTION PLAN
CONSISTENCY CHECKLIST
B-50
Development Services
Building Division <
1635 Faraday Avenue
www.carlsbadca.gov
PURPOSE
This checklist is intended to help building permit applicants identify which Climate Action Plan (CAP) ordinance requirements
apply to their project. This completed checklist (B-50) must be included with the building permit application. The Carlsbad
Municipal Code (CMC) can be referenced during completion of this document by clicking on the provided links to each
municipal code section.
NOTE: The following type of permits are not required to fill out this form
❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool
Consultation with a certified Energy Consultant is encouraged to assist in filling out this document. Appropriate
certification includes, but is not limited to: Licensed, practicing Architect, Engineer, or Contractor familiar with Energy
compliance, IECC/HERS Compliance Specialist, ICC GS Energy Code Specialist, RESNET HERS rater certified, certified
ICC Residential Energy Inspector/Plans Examiner, ICC Commercial Energy Inspector and/or Plans Examiner, ICC CALgreen
Inspector/Plans Examiner, or Green Building Residential Plan Examiner.
If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance,
check NIA and provide an explanation or code section describing the exception.
Details on CAP ordinance requirements are available at each section by clicking on the municipal code link provided. The
project plans must show all details as stated in the applicable Carlsbad Municipal Code (CMC) and/or Energy Code and
Green Code sections.
Project Name/Building
Permit No.:
Property Address/APN:
Applicant Name/Co.:
Applicant Address:
Contact Phone:
CBC2021-0319
1545 Faraday Avenue, Suite 100, Carlsbad, CA 920081/// APN: 212-130-29-00
Chad Johnston -CWHQ Carlsbad, LLC c/o Capstone Advisors
1545 Faraday Avenue, Suite 100, Carlsbad, CA 92008
(760) 827-6010 Contact Email: johnston@capstoneadvisors.com
Contact information of person completing this checklist (if different than above):
Name:
Company
name/address:
Chad Johnston
Capstone Advisors
Contact Phone (760) 827-6010
Contact Email: johnston@capstoneadvisors.com
8/27/2021 Date: ________ _
Page1of7 Revised 04/21
DocuSign Envelope ID: 25B682E6-4003-4411-AA6C-B88803A851 DE
'
Use the table below to determine which sections of the Ordinance checklist are applicable to your project. For
alterations and additions to existing buildings, attach a Permit Valuation b[reakdown on a separate sheet.
Building Permit Valuation (BPV) $ breakdown -'1'-'-7--=0_,_,,6'--'9---'4 ____ _
A high,tiseresidentialbuilding 1s4 or morestoiies, in6Judin'g'~
Low-rise High-rise mixed04se building in which atleast 20% of its c~~d!ll9n~di(!p,o/,f
area isresidential use · · ' '
□ New consbucfion 2A', 3A', 1B, 2B, 'Includes detached, newly constructed ADU 4A', 3B,4A
□ Additions and alterations:
□ BPV < $60,000 N/A N/A All residential additions and alterations
□ BPV" $60,000 1A, 4A 4A 1-2 family dwellings and townhouses with attached garages
□ Electrical service panel upgrade only only.
□ BPV" $200,000 1A, 4A'
'Multi-family dwellings only where interior finishes are removed
1 B, 4A' and significant site work and upgrades to structural and
mechanical, electrical, and/or plumbing systems are proposed
'
□ New consbucfion 1 B, 2B, 3B, 4B and 5
11!1 Alterations: <$200k Tl in existing office building
)&G BPV" $200,000 or additions" 1,000
square feet 1B, 5
□ BPV" $1,000,000 1B, 2B, 5 Building alterations of" 75% existing gross floor area
□ " 2,000 sq. ft. new roof addition 2B, 5 1B also applies if BPV" $200,000
1. Energy Efficienty
Please refer to Cansbad Municipal Code (CMC) 18.21.155 and 18.30.190,and the California Green Building Standards Code (CALGreen) for more
infonmation. Appropriate details and notes must be placed on the plans according to selections chosen in the design.
A. D Residential addition oralteration2:$60,000 building penmitvaluation. □ N/A,_cN=A,_ ________ _
Details of selection chosen below must be placed on the plans referencing CMC □ Exception: Home energy score" 7
18.30.190. (attach certification)
Year Built Single-family Requirements Multi-family Requirements
□ Before 1978 Select one option:
□ Ductsealing □ Attic insulation □Cool roof □ Attic insulation
□ 1978 andlater Select one option:
□ Lighting package □ Water heating Package
□ Between 1978 and 1991 Select one option:
□ Ductsealing □ Attic insulation □Coo/roof
□ 1992 and later Select one option:
□ Lighting package □ Water heating package
Updated 4/16/2021
(
3
DocuS1gn Envelope ID: 25B682E6-4003-4411-AA6C-B88803A851 DE .,
B. \ Nonresidential' new construction or alterations l: $200,000 building pennit valuation,
or additions l! 1,000sq uare feet See CMC 18.21'155 and CALGreen Appendix AS !!I NIA N/A ~---------
AS.203.1.1 Choose one:□. 1 Outdoor lighting D .2 Restaurant service water heating (CEC 140.5)
D .3 Warehousedockseal doors. D .4 Daylight design PA,-s D .5 Exhaustairheatrecovery !!I N/A N/ A
A5.203.1.2.1 Choose one:□ .95 Energy budget (Projects with indoor lighting OR mechanical)
□ .90 Energy budget (ProjectswithindoorlightingANDmechanical) I!!! N/A N/ A
AS.211.1" □ On-site renewable energy:
~ NIA N/A
AS.211.3~ D Green power (If offered by local utility provider, 50% minimum renewable sources)
Iii N/A N/A
AS.212.1 D Elevators and escalators: (Project with more than oneelevatorortwo escalators)
~ N/A N/A
AS.213.1 □ Steel framing: (Provide details on plans for options 1-4 chosen)
~ N/A N/A
* Includes hotels/motels and high-rise residential buildings
•• Foralterations~ $1,000,000 BPV and affecting> 75%existing grossfloorarea, OR alterations that add 2, OOOsquarefeetof newroofaddition: comply
with CMG 18.30.130 (section 2B below) instead.
2. Photovoltaic Systems
A. 0 Residential new construction (for low-rise residential building permit applications submitted after 1/1/20). Refer to 2019 California
Energy Code section 150.1{c)14 for requirements. If project includes installation of an electric heat pump water heater pursuant to
CAP section 3B below(low-rise residentialWaterHeating), increase system size by .3kWdc if PV offset option is selected.
Floor Plan ID (use additional CFA #d.u. Calculated kWdc*
sheets if necessary)
Total System Size:
kWdc = (CFAx.572) / 1,000 + (1.15 x #d.u.)
*Formula calculation where CFA ;::;:: conditional floor area, #du;::;:: number of dwellings per plan type
If proposed system size is less than calculated size, please explain.
kWdc
Exception
D
D
D
D
B. D Nonresidential new construction or alterations l:$1,000,000 BPV AND affecting l:75% existing floor area, OR addition that increases
roof area by l!2,000 square feet Please refer to CMC 18.30.130 when completing this section. 'Note: This section also applies to
high-rise residential and hotel/motel buildings.
Choose one of the following methods:
□ Gross Floor Area (GFA)Method
GFA:
□ If< 10,000s.f Enter: 5 kWdc
Min.System Size:
□ If< 10,000s.f. calculate: 15 kWdcx (GFA/10,000) ••
kWdc
**Round building size factor to nearest tenth, and round system size to nearest whole number.
Updated 4/16/2021 4
DocuSign Envelope ID: 256682E6-4003-4411-AA6C-B88803A851 DE
□ Time-Dependent Valuation Method
Annual TDV Energy use:*** _______ x .80= Min. system size: ______ kWdc
··• Attach calculation documentation using modeling software approved by the California Energy Commission.
3. Water Heating
A D Residential and hotel/motel new construction. Refer to CM€ 18.30.170 when completing this section.
Provide complete details on the plans.
□ For systems serving individual dwelling units choose one system:
□ Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise
residential only)
□ Heat pump water heater AND PV system .3 kWdc larger than required in CMC 18.30.130 (high rise
residential hotel/motel) or CA Energy Code section 150 1(c) 14 (low-rise residential)
D Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher
D Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors
D Exception:
D For systems serving multiple dwelling units, install a central water-heating system with ALL of the following:
D Gas or propane water heating system
D Recirculation system per CMC 18.30.150(8) (high-rise residential, hotel/motel) or CMC 18.30.170(8) (low-
rise residential)
D Solar water heating system that is either:
D .20 solar savings fraction
D .15 solar savings fraction, plus drain water heat recovery
D Exception:
B. D Nonresidential new construction. Refer to CMC 18.30.150 when completing this section. Provide
complete details on the plans.
D Water heating system derives at least 40% of its energy from one of the following (attach documentation):
D Solar-thermal □ Photovoltaics D Recovered energy
D Water heating system is (choose one):
D Heat pump water heater
D Electric resistance water heater(s)
□Solar water heating system with .40 solar savings fraction
D Exception:
It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to
demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a
performance approach to comply with energy-related measures will need to attach to this checklist separate calculations
and documentation as specified by the ordinances.
Updated 4/16/21 5
DocuSign Envelope ID: 25B682E6-4003-4411-AA6C-B88803A851 DE
4. Electric V~hicle Charging
A. 0 Residential New construction and major alterations•
Please refer to CMC 18.21.140 when completing this section.
□ One and two-family residential dwelling or townhouse with attached garage:
□ One EVSE Ready parking space required □ Exception :
-□ Multi family residential· □ Exception
Total Parking Spaces EVSE Spaces
Proposed EVSE (10% of total) Installed (50% of EVSE) Other "Ready" Other "Capable"
Calculations: Total EVSE spaces= .1 Ox Total parking spaces proposed(rounded upto nearestwhole number) EVSE Installed= Total EVSE
Spaces x .50 (rounded up to nearest whole number) EVSE other may be "Ready" or "Capable"
*Major alterations are: ( 1 ) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit
valuation~$60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached
garages), alterations have a building penmit valuation~ $200,000, interior finishes are removed and significantsitework and upgrades to
structural and mechanical, electrical, and/or plumbing systems are proposed.
'ADU exceptions for EV Ready space (no EV ready space required when):
(1) The accessory dwelling unit is located within one-half mile of public transit.
(2) The accessory dwelling unit is located within an architecturally and historically significant historic district.
(3) The accessory dwelling unit is part of the proposed or existing primary residence or an accessory structure.
(4) When on-street parking permits are required but not offered to the occupant of the accessory dwelling unit.
(5) When there is a car share vehicle located within one block of the accessory dwelling unit.
B. D Nonresidential new construction (includes hotels/motels) □ Exception : _____________ _
Please refer to CMC 18.21.150 when completing this section
Total Parking Spaces
Proposed EVSE (10% of total) I Installed (SO% of EVSE) Other "Ready" Other "Capable"
I
Calculation· Refer to the table below:
Total Number of Parking Spaces provided Number of required EV Spaces Number of required EVSE Installed Spaces
□ 0-9 1 1
□ 10-25 2 1
□ 26-50 4 2
□ 51-75 6 3
□ 76-100 9 5
□ 101-150 12 6
□ 151-200 17 9
□ 201 and over 1 D percent of total 50 percent of Required EV Spaces
Calculations: TotalEVSEspaces=.10xTotalparking spaces proposed (roundeduptonearestwholenumber) EVSE Installed= Total EVSE
Spaces x .50 (rounded up to nearest whole number) EVSE other may be "Ready'' or "Capable"
Updated 4/16/2021 6
DocuSign Envelope ID: 25B682E6-4003-4411-AA6C-B88803A851 DE
An approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT.
City staff will use the table below based on yoursubmitted plans to detenminewhetherornoryourpenmit requires a TDM plan. lfTDM is applicable to your
permit, staff will contact the applicantto develop a site-specific TOM plan based on the permit details.
Acknowledgment:
Employee ADT Estimation for Various Commercial Uses
Office (all), 20
Restaurant 11
Retail, 8
Industrial 4
Manufacturing 4
Warehousing 4
1 Unless otherwise noted, rates estimated from /TE Trip
Generation Manual, 10thEdition
13
11
4.5
3.5
3
1
2 For all office uses, use SANDAG rate of 20 ADT/1,000 sf to
calculate employee ADT
, Retail uses include shopping center, variety store, supermarket,
gyms, pharmacy, etc.
Other commercial uses may be subject to special
consideration
Sample calculations·
Office: 20,450 sf
1. 20,450 sf/ 1000 x 20 = 409 Employee ADT
Retail: 9,334 sf
1. First 1,000 sf= 8 ADT
2. 9,334 sf -1,000 sf= 8,334 sf
3. (8,334 sf/ 1,000 x 4.5) + 8 = 46 Employee ADT
I acknowledge that the plans submitted may be subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should
my permit require a T g)OOJl,IW,,Vnderstand that an approved TDM plan is a condition of penmit issuance.
c.,___...,., l'\W'l:.,k,I'\, s;21 ;2021
ApplicantSignature:+---cc==~7=,,.-------------Date: ______ _
Person other than Applicant to be contacted for TDM compliance (if applicable):
Name(Printed): __________________ _ Phone Number _____ _
Email Address: ___________________ _
Updated 4/16/2021 7
C l I ii I i • ., ~ l i ~ •I, ~! .• (i i "e e ~ .. ..-~ ..... "' i . ~ j ~ ' gooz6 vJ '1"'9'1..,J ~;;i,,,v fEpe.ied ,,;v,:;1 OH ;:cJUO'.fSdr?J
f--
~
' ~ -~~ "' -• ~
0
l i,t)
f lg ~ 2
@ E8
J -
I:
r--
I/
~ ~~ ~ -• ' 0
•
---------------~-----~~~-~~---------gooz6 VJ 'P"9'1"J ;;;ru;;;AV ht'.'pE?..E'J '::ilr'::il OH ;;>UO'.}Sdl?J
-
~ _\
I:\_
z C)
':c <;:,. z :::,
C)
IL
' z C)
':c > C) z
\;z
ll.\ u
IL
IL C)
~~ b
1B ,-t ~\ _j ~
~ "'-' I-" ~, G
I n M
~
i
I I
' I I I I
~ _\ I:\_ ~~= 13 ts -~ z
' I ! ' LJ IL
13
iEP . ~ z
_\
ll.\
B, . ~-.,;; ~ u
' z ~ ~8 ~I C)
':c > J C) z
' \;z
a ll.\ u ' IL IL C) ~~ ~ 0 "' -
. •