Loading...
HomeMy WebLinkAbout1545 FARADAY AVE; 100; CBC2021-0319; PermitPERMIT REPORT (city of Carlsbad Commercial Permit Print Date: 03/24/2022 Permit No: CBC2021-0319 Job Address: 1545 FARADAY AVE, # 100, CARLSBAD, CA 92008-7450 Status: Closed -Finaled Permit Type: BLDG-Commercial Work Class: Tenant Improvement Parcel#: 2121302900 Track#: Valuation: $276,176.38 Lot#: Occupancy Group: B Project#: #of Dwelling Units: Plan#: Bedrooms: Construction Type:V-8 Bathrooms: Orig. Plan Check#: Plan Check#: Project Title: Description: CAPSTONE: 5,938 SF T.I. (OFFICE TO OFFICE) Property Owner: FEE CW H Q CARLSBAD LLC 1545 FARADAY AVE CARLSBAD, CA 92008 COMM RES & MULTI RES REMODELS-NON-STRUCTURAL 581473 -GREEN BUILDING STATE STANDARDS FEE BUILDING PLAN CHECK FEE (BLDG) STRONG MOTION -COMMERCIAL (SMIP) GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION BUILDING PLAN REVIEW-MINOR PROJECTS (LOE) BUILDING PLAN REVIEW-MINOR PROJECTS (PLN) Total Fees: $3,668.81 Total Payments To Date: $3,668.81 Applied: 08/25/2021 Issued: 10/20/2021 Finaled Close Out: 03/24/2022 Inspector: Final Inspection: Contractor: TAlva 12/14/2021 SPW CONSTRUCTION DBA WHITE CONSTRUCTION 2524 GATEWAY RD CARLSBAD, CA 92009 (760) 931-1130 Balance Due: AMOUNT $2,234.44 $12.00 $878.04 $77.33 $175.00 $194.00 $98.00 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov ( City of Carlsbad Job Address 1545 Faraday Avenue COMMERCIAL BUILDING PERMIT APPLICATION B-2 Plan Check cgt:r, ~-Q;/9 Est. Value 7 7-J, 3- PC Deposit Date Suite: :#{QO APN:,_2_12_-_13_0_-2_9 ______ _ Tenant Name #:_C_a.,_p_st_o_n_e _____________ Lot #: ____ Year Built: _________ _ Year Built:, __ _ Occupancy: 8 (office) Construction Type: V-N Fire sprinklers@ESQNO A/C:QYESQNO BRIEF DESCRIPTION OF WORK: minor demo and new structural for new office glass system (interior), new storefront door, lighting and finishes D Addition/New: ____________ New SF and Use, __________ New SF and Use _______ SF Deck, _______ SF Patio Cover, ________ SF Other (Specify) ___ _ IZ]Tenant Improvement: .:.5:..:,9.:.3.:.8 ___ SF, Existing Use: _o_ff_ic_e _____ Proposed Use: _off_i_ce ____ _ _____ SF, Existing Use: Proposed Use: ______ _ D Pool/Spa:. _____ SF Additional Gas or Electrical Features? ____________ ~ D Solar: ___ KW, ___ Modules, Mounted: 0Roof 0Ground D Reroof:. ____________________________________ _ IZ] Plumbing/Mechanical/Electrical no plumbing, duct work only for mechancial, minor electric~ Dother: ______________________________ _ PRIMARY APPLICANT Name:SPW Construction (White Construction) Address: 2524 Gateway Road City: Carlsbad State:._C_A_~Zip: 92009 Phone: 760.931.1130 Email: nancy@wh iteconstruction inc.com PROPERTY OWNER Name: CWHQ Carlsbad, LLC c/o Capstone Advisors Address: 1545 Faraday Avenue City: Carlsbad state: CA Zip:._9_2_0_08 __ _ Phone: 760.804.6900 x 11 O Email: johnston@capstoneadvisors.com DESIGN PROFESSIONAL CONTRACTOR OF RECORD Name:McCulley Design Lab Business Name:SPW Construction (White Construction) Address:224 South Cedros Avenue Studio A Address:2524 Gateway Road City: Solana Beach State: CA Zip:,_9_2_07_5 ___ City: Carlsbad State.:_ C_A __ Zip: 92009 Phone:858. 756.1807 Phone: 760. 731.1130 Email: amanda@mcculleydesign.com Email: nancy@whiteconstructioninc.com Architect State License: __________ _ CSLB License#: 1023856 Class:B ·------- Carlsbad Business License# (Required): BLNR000431-02-2017 APPLICANT CERT/FICA TION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. /agree to comply with all City ordinances and State laws relating to building construction. NAME (PRINT): Nancy Young, PM SIGN: J/"V'>c-g DATE: 8/23/2021 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: f?u1_l_d1_ng@~Jrl',b,H.icd.gov REV. 07/21 THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _ A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE. (OPTION A): LICENSED CONTRACTOR DECLARATION: I herebyaffi rm under penalty af per jury that/ am I icensed under provisions of Chapter 9 (commencing with Section 7000 / of Division 3 of the Business and Professions Code, and my I icense is in full force and effect. I also affirm under penalty of perjury one of the following declarations (CHOOSE ONE): D1 have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit 1s issued. Policy No. ________________________________________ _ -0R- ~I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: lnsuranceCompany Name: _s_ea_te_c_o_m~p,_,_~_,,_oc_,_cs_._Fo_c_d _____________ _ Policy No. 9243036-21 Expiration Date: _11_,_,,_02_2 _____________ _ -0R- Ocertificate of Exemption: I certify that 1n the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit IS issued (Sec. 3097 (i} Civil Code), Lender's Name:. _____________________ Lender's Address: _____________________ _ CONTRACTOR CERTIFICATION: /certify that/ have read the application and state that the above information is correct and that the information on the plans is accurate. /agree to comply with all City ordinances and State laws relating to building construction. · OR - (OPTION B): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure 1s not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). -0R-D1, as owner of the property, am exclusively contracting with licensed contractors to construct the project {Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). -0R-□1 am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason: .\~I). D FORM B-61 "Owner Builder Acknowledgement and Verification Form" is required for any permit issued to a property owner. By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed contractors. I understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application is submitted or at the following Web site: http:Ilwww.leginfo.ca.govl ca/aw. html. OWNER CERT/FICA T/ON: I certify that I have read the application and state that the above information is correct and that the information on the plansisaccurate. /agree to comply with all City ordinances and State laws relating to building construction. NAME (PRINT): _________ _ SIGN: __________ DATE: ______ _ Note: If the person signing above is an authorized agent for the property owner include form B-62 signed by property owner. 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-85S8 Email Budding@carlsbadca.gov 2 REV 07/21 PERMIT INSPECTION HISTORY for (CBC2021-0319) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Application Date: 08/25/2021 Issue Date: 10/20/2021 Owner: C W H Q CARLSBAD LLC Subdivision: CARLSBAD TCT#85-24 UNIT#05 Address: 1545 FARADAY AVE, # 100 Status: Closed -Finaled Expiration Date: 05/23/2022 IVR Number: 35497 CARLSBAD, CA 92008-7450 Scheduled Date 11/22/2021 12/14/2021 Actual Inspection Type Start Date Inspection No. Inspection Status Primary Inspector 11/22/2021 12/14/2021 Checklist Item BLDG-Building Deficiency COMMENTS Rough frame combination Inspection for interior tenant improvement Shell. non-loadbearing steel framed (structural steel) partition walls-approved per plan. Shearwall fastening method of attachment alteration, located in office area - approved per plan. BLDG-84 Rough Combo(14,24,34,44) 171122-2021 Passed Tony Alvarado Checklist Item BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers COMMENTS Rough frame combination Inspection for interior tenant improvement Shell. non-foadbearing steel framed (structural steel) partition walls-approved per plan. Shearwall fastening method of attachment alteration, located in office area - approved per plan. Rough frame combination Inspection for interior tenant improvement Shell. non-loadbearing steel framed (structural steel) partition walls-approved per plan. Shearwall fastening method of attachment alteration, located in office area - approved per plan. Rough frame combination Inspection for interior tenant improvement Shell. non-loadbearing steel framed (structural steel) partition walls-approved per plan. Shearwall fastening method of attachment alteration, located in office area - approved per plan. BLDG-17 Interior 171201-2021 Passed Tony Alvarado Lath/Drywall Checklist Item COMMENTS BLDG-Building Deficiency BLDG-Final Inspection 172639-2021 Passed Tony Alvarado Checklist Item COMMENTS BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Thursday, March 24, 2022 Reinspection Inspection Passed Yes Complete Passed Yes Yes Yes Complete Passed No Complete Passed Yes Yes Yes Page 2 of 2 Building Permit Inspection History Finaled ( City of Carlsbad PERMIT INSPECTION HISTORY for (CBC2021-0319) Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status: Closed -Finaled Scheduled Actual Inspection Type Date Start Date 10/2512021 10125/2021 BLDG-21 Underground/LI nderflo or Plumbing Checklist Item Application Date: 08/25/2021 Issue Date: 10/20/2021 Expiration Date: 05/23/2022 IVR Number: Inspection No. 169231-2021 COMMENTS 35497 Inspection Status Passed Owner: CW HQ CARLSBAD LLC Subdivision: CARLSBAD TCT#85-24 UNIT#05 Address: 1545 FARADAY AVE, # 100 CARLSBAD, CA 92008-7450 Primary Inspector Reinspection Inspection Tony Alvarado Complete Passed BLDG-Building Deficiency October 25, 2021: Yes 1111012021 11/1912021 BLDG-31 Underground/Conduit - Wiring Checklist Item 1. No building Deficiencies. 2. Underground electrical conduit, no new electrical circuit added, scope of electrical work-approved. 3. interior tenant improvement, with no alterations to existing exterior structure. 169244-2021 Passed Tony Alvarado COMMENTS BLDG-Building Deficiency October 25, 2021: 11/1012021 BLDG-14 FramefSteel/Boltlng/We lding (Decks) Checklist Item 1. No building Deficiencies. 2. Underground electrical conduit. no new electrical circuit added, scope of electrical work-approved. 3. interior tenant improvement, with no alterations to existing exterior structure. 170517-2021 Passed Tony Alvarado COMMENTS BLDG-Building Deficiency November 10, 2021: 11/19/2021 BLDG-13 Shear Panels/HD (ok to wrap) 1. No framing Building Deficiencies. 2. Interior structural moment frame connections and footings approved per revised structural engineer's plan, structural calculations, third-party deputy inspector, and structural engineer's calculations, for interior alterations (only)- approved. 3. Rough electrical min. alterations, located at (e)structural loadbearing wall, office number unit area #108, scope of electrical work -approved. 4. OK to cover with shear plywood. 171155-2021 Passed Tony Alvarado Thursday, March 24, 2022 Complete Passed Yes Complete Passed Yes Complete Page 1 of 2 Inspection Report Project Name: __ C_a~p_s_t_o_n_e_H_Q ___ _ Page: _1_ of _1_ Report# ____ _ Project Address: __ 1..,5..,;4=u.5'-'-F ..... a..,ru.a...,d ........ a'--JyL---L-'a .... vu.e~-- Architect: Permit#: Cbc2021-0139 File#: -------------------------------- DSA#: Engineer: __ ~~~---------------------------White Contractor: _________________ _ Other: ____________ _ INSPECTION MATERIAL SAMPLING QTY MATERIAL DESCRIPTION INSPECTION CHECKLIST -Structural Steel -H.S. Bolts -H.S. Bolts .L... Plans/Specs _ Masonry Prisms Cone. PSI Clearances --- -Concrete Mortar/ Grout -Grout PSI -Positions Fireproofing _ Cone. Cylinders Mortar PSI .L... Sizes 7 Epoxy _ Fireproof 7 Steel 7/8" _ Laps -Other: -Other: Elect./Wire -Consolidation Other: Other: _ Fireproof _ Torque Ft. Lbs: -- -Other: -Other: L Other: .L_ Other: 15" Embed Other: Other: L Other: Simpsca XP .L... Other: 2508 Performed special inspection on the installation of 2 total 7/8 all thread retrofit HDl JS baldawn baits into existing foundation per detail 2/S1 Verified bolt, bar types, sizes, hole sizes, depth, location, cleanliness, and epoxy type prior to installation. CERTIFICATION OF COMPLIANCE: All reported work, unless otherwise noted, complies with approved plans, specifications and applicable sections of the building codes. This report covers the locations of the work inspected and does not constitute opinion or project control. I hereby certify that I have observed to the best of my knowledge all of the above reported work unless otherwise noted. I have found this work to comply with the approved plans, specifications, and applicable sections of the governing building laws. INSPECTOR: GIANNI BATTAGLIA CERT: 1323 ~ 11-9-21 Signature Date lnsp. Date: Day 1: I Day 2: I Day 3: I Day 4: I Day 5: I Time Start: Time Stop: Approved By: __________ _ I I ' ' tel -818-6Jl-8900 hee -855-787-4522 tax -B58-6n-9009 Patri-011.at.com 6640 Lusk Blvd_, Suite A-100, San Diego, CA 92121 September 8, 2021 Nancy Young White Construction Inc. 2524 Gateway Road Carlsbad, CA 92009 Re: Limited Asbestos Survey Capstone 1545 Faraday Avenue, Suite 100 Carlsbad, CA 92008 Job No: 14867 Project No: SD 150095 Dear Ms. Young, PA Environmentar Laboratory Services, Inc. On September 7. 2021, California DOSH Certified Site Surveillance Technician, Mr. Brennan Bales (CSST # 19-6731) of Patriot Environmental Laboratory Services, Inc. (Patriot) performed a limited asbestos inspection at the above subject property located in Carlsbad, California. The purpose of the inspection was to determine if asbestos is present in the building materials soon to be disturbed by an upcoming renovation at the subject property. Summary of Findings No asbestos was detected in the building materials sampled. Property Description The subject property is a commercial structure. The subject building is a two-story metal frame building set on a cement slab foundation. Scope of Work On September 7, 2021, Mr. Brennan Bales, (CSST # 19-6731) of Patriot conducted a limited asbestos inspection at the subject property. The interior of the building was visually inspected for the purpose of identifying suspect asbestos containing materials soon to be disturbed by an upcoming renovation at the subject property. Once the inventory of suspect materials was created, physical bulk samples of the materials were collected from representative locations. Samples were collected in airtight containers. Upon collection, sample numbers, descriptions, and collection locations were entered on to a chain of custody for transportation to Patriot's NVLAP accredited laboratory. Sampled Suspect Materials Samples of the following suspect materials were collected: 4" Grey Cove Base with Mastic Car et Tile Mastic Sample Protocol/Analysis 4" Black Cove Base with Mastic Bamboo Floorin Adhesive l 2"x 12" Black Vinyl Floor Tile with Mastic Samples were collected in accordance with the Asbestos Hazard Emergency Response Act ( 40 CFR 763 Subpart E) as mandated by Cal/OSHA (Title 8 Section 1529) and San Diego Air Pollution Control District Rule 1206. Physical bulk samples were analyzed by Patriot. Patriot is accredited by the National Voluntary Laboratory Accreditation Program (200982). The method of analysis was Polarized Light Microscopy (EPA 600/M4-82-020). Recommendations No asbestos was detected in the building materials sampled. Therefore, no recommendations are warranted at this time. Disclaimer Limited destructive sampling was conducted at the subject property. If additional suspect materials are discovered during renovation, all work should cease until a Certified Asbestos Consultant is contracted to determine the asbestos content of the building materials. This inspection was performed in accordance with current regulations and state of the art practices. The inventory of asbestos containing materials and determination of their condition are based upon observations at the time of inspection. Patriot does not assume responsibility for future regulatory changes or changes in the condition of the building or materials. Enclosed is the laboratory analysis report and sample location diagram. Please contact our office if there are any questions regarding this inspection. Sincerely, Patriot Environmental Laboratory Services, Inc. fr Zach Levin Certified Asbestos Consultant No. 16-5772 Attachments: Laboratory Resu Its Sample Location Diagram Certifications Certificate of Analysis PLM Asbestos Identification White Construction Inc. Nancy Young 2524 Gateway Road Carlsbad, CA 92009 Date Collected: 9nl2021 Date Received: 9n!2021 Date Analyzed, 9/8/2021 Date Reported: 9/8/2021 Lab/Client ID/Layer Location 878108-001 0.0 -Wall Total Asbestos None Detected 878108-002 0.0-Wall 2 Total Asbestos None Detected 878108-002C 0.0 -Wall 2 Total Asbestos None Detected 878108-003 0.0 -Wall 3 Total Asbestos None Detected 878108-004 0.0 -Wall 4 Total Asbestos None Detected 1e1 -ass-m-sm lree -8lH8Hm S[)l,~j!ipalriotfa~.(0111 DA'1 m~T LAB li/,,10 LlllJc Blvd., lule A·IOO, S.R !lie9o, (A 92111 .-"' .:JJ' Report Number: 878108 Project Number: SO150095 Project Name: Capstone Project Location: 1545 Faraday A venue Suite I 00 Carlsbad, CA 92008 Collected By: Brennan Bales Claim Number: Job #14867 PO Number, Number of Samples: 51 Material Description Color Composition ( % ) Drywall White 70% Non- Fibrous Material 25% Cellulose 5% Glass Fibers Joint Compound White 100% Non- Fibrous Material Drywall and Joint White 80% Sulfate Compound 10% Cellulose 6% Carbonate 2 % Glass Fibers 2% Paint Drywall White 70% Non- Fibrous Material 25% Cellulose 5% Glass Fibers Joint Compound White 100% Non- Fibrous Material Page I of 10 Certificate of Analysis PLM Asbestos Identification White Construction Inc. Nancy Young 2524 Gateway Road Carlsbad, CA 92009 Date Collected: 9/7/2021 Date Received: 9/7/2021 Date Analyzed: 9/8/2021 Date Reported: 9/8/2021 Lab/Client ID/Layer 878108-004C 4 Total Asbestos 878108-005 5 Total Asbestos 878108-006 6 Total Asbestos 878108-006C 6 Total Asbestos 878108-007 7 Total Asbestos Location 0.0 -Wall None Detected 106-Wall None Detected 106-Wall None Detected 106 -Wall None Detected 102 -Wall None Detected tel -8,8-&54-5117 lree • 8ll· l8Hm IDlab@palriot~ll.com n A I , ,::w~T LAB 6640 Lllll< 81Yd., lule A-100, San l)iego, 0. 92111 .-'"' , • .:J' Report Number: 878108 Project Number: SDl50095 Project Name: Capstone Project Location: 1545 Faraday A venue Suite I 00 Carlsbad, CA 92008 Collected By: Brennan Bales Claim Number: Job #14867 PO Number: Number of Samples: 51 Material Description Drywall and Joint Compound Drywall Joint Compound Drywall and Joint Compound Drywall Color White White White White White Composition ( % ) 80% Sulfate I 0% Cellulose 6% Carbonate 2% Glass Fibers 2% Paint 70% Non- Fibrous Material 25% Cellulose 5% Glass Fibers 100% Non- Fibrous Material 80% Sulfate 10% Cellulose 6% Carbonate 2% Glass Fibers 2% Paint 70% Non- Fibrous Material 25% Cellulose 5% Glass Fibers Page 2 of 10 Certificate of Analysis PLM Asbestos Identification White Construction Inc. Nancy Young 2524 Gateway Road Carlsbad, CA 92009 Date Collected: 9/7/2021 Date Received: 9/7/2021 Date Analyzed: 9/8/2021 Date Reported: 9/8/2021 Lab/Client ID/Layer 878108-008 8 Total Asbestos 878108-008C 8 Total Asbestos 878108-009 9 Total Asbestos 878108-010 IO Total Asbestos 878108-0I0C 10 Total Asbestos Location 102 -Wall None Detected 102 -Wall None Detected 103 -Wall None Detected 103-Wall None Detected 103-Wall None Detected lei -BSS-.il->227 l~e -8ll-J8Mll7 sm,1>o,patriot1,1uo111 DA•, , ... ~T LAB 6640 ltJsk Blv,L Su~• A-100, SanfJl!11'), CA 92121 .-" ,.~ Report Number: 878108 Project Number: SD150095 Project Name: Capstone Project Location: 1545 Faraday Avenue Suite 100 Carlsbad, CA 92008 Collected By: Brennan Bales Claim Number: Job #14867 PO Number: Number of Samples: 51 Material Description Color Composition ( % ) Joint Compound Drywall and Joint Compound Drywall Joint Compound Drywall and Joint Compound White White White White White 100% Non- Fibrous Material 80% Sulfate 10% Cellulose 6% Carbonate 2% Glass Fibers 2% Paint 70% Non- Fibrous Material 25% Cellulose 5% Glass Fibers 100% Non- Fibrous Material 80% Sulfate 10% Cellulose 6% Carbonate 2% Glass Fibers 2% Paint Page 3 of 10 Certificate of Analysis PLM Asbestos Identification White Construction Inc. Nancy Young 2524 Gateway Road Carlsbad, CA 92009 Date Collected: 9/712021 Date Received: 9/7/2021 Date Analyzed: 9/8/2021 Date Reported: 9/8/2021 Lab/Client ID/Layer 878108-011 I I Total Asbestos 878108-012 12 Total Asbestos 878108-013 13 Total Asbestos 878 I 08-014 14 Total Asbestos 878108-015 15 Total Asbestos 878108-016 16 Total Asbestos Location 0.0 -Wall None Detected 0.0 -Wall None Detected 106 -Wall None Detected 102 -Wall None Detected 103-Wall None Detected I 06 -Ceiling None Detected lel · 8S3-654-Sll7 tree -8l3· l8l-lll7 IOI.JIJ(•'patri<lllab.com n A I • ,-~T LAB fil>40 Llllk Blvd,. lu~eA-100, San Diego, CA 92111 ■--"' ,■.:, Report Number: 878108 Project Number: SD150095 Project Name: Capstone Project Location: 1545 Faraday Avenue Suite 100 Carlsbad, CA 92008 Collected By: Brennan Bales Claim Number: Job #14867 PO Number: Number of Samples: 51 Material Description Color Composition ( % ) Wall Texture White Wall Texture White Wal I Texture White Wall Texture White Wa11 Texture White Ceiling Tile Grey 100% Non- Fibrous Material 100% Non- Fibrous Material 100% Non- Fibrous Material 100% Non- Fi bro us Material 100% Non- Fibrous Material 73% Cellulose 22% Minerals 5% Glass Fibers Page 4 of 10 Certificate of Analysis PLM Asbestos Identification tel · 818-654-1111 lree · 83H8Hl27 SDla~~•palrioll.lb,com nA·. ,:sa~T LAB tiMO L~ Bh,t, lu~d-100, San Diego, CA 92111 .--"". ,■ ~ White Construction Inc. Nancy Young 2524 Gateway Road Carlsbad, CA 92009 Date Collected: 9n /2021 Date Received: 9/7/2021 Date Analyzed: 9/8/2021 Date Reported: 9/8/2021 Lab/Client ID/Layer 878108-017 17 Total Asbestos 878108-018 18 Total Asbestos 878108-019 19 Total Asbestos 878108-020 20 Total Asbestos 878108-021 21 Total Asbestos 878108-022 22 Total Asbestos Location 106 -Ceiling None Detected 103 · Ceiling None Detected 103 -Wall None Detected 103 -Wall None Detected 102 -Wall None Detected 102-Wall None Detected Report Number: Project Number: Project Name: Project Location: Collected By: Claim Number: PO Number: 878108 SD150095 Capstone 1545 Faraday Avenue Suite 100 Carlsbad, CA 92008 Brennan Bales Job #14867 Number of Samples: 51 Material Description Color Composition ( % ) Ceiling Tile Grey Ceiling Tile Grey 4 Inch Cove Base Black Mastic Yellow 4 Inch Cove Base Black Mastic Yellow 73% Cellulose 22% Minerals 5% Glass Fibers 73% Cellulose 22% Minerals 5% Glass Fibers 100% Non- Fibrous Material 100% Non- Fibrous Material 100% Non- Fibrous Material 100% Non- Fibrous Material Page 5 of 10 Certificate of Analysis PLM Asbestos Identification lei • 8SH54·5111 r,ee · SlH8J.S117 SOLl~~:p;atrtotl;aluom nA•. ,-~T LAB 6640 tu;k lllv1t, lui!d·IOO, Sa, lliego, CA 92121 .-" ,■.:, White Construction Inc. Nancy Young 2524 Gateway Road Carlsbad, CA 92009 Date Collected: 9/7/202 I Date Received: 9/7/2021 Date Analyzed: 9/8/2021 Date Reported: 9/8/2021 Lab/Client ID/Layer 878108-023 23 Total Asbestos 878108-024 24 Total Asbestos 878108-025 25 Total Asbestos 878108-026 26 Total Asbestos 878108-027 27 Total Asbestos 878108-028 28 Total Asbestos Location 106 · Wall None Detected 106 · Wall None Detected Kitchen -Wall None Detected Kitchen -Wall None Detected Kitchen -Wall None Detected Kitchen -Wall None Detected Report Number: Project Number: Project Name: Project Location: Collected By: Claim Number: PO Number: 878108 SDl50095 Capstone 1545 Faraday A venue Suite I 00 Carlsbad, CA 92008 Brennan Bales Job #14867 Numberof Samples: 51 Material Description Color 4 Inch Cove Base Black Mastic Yellow 4 Inch Cove Base Black Mastic Yellow 4 Inch Cove Base Black Mastic Yellow Composition ( % ) 100% Non- Fibrous Material 100% Non- Fibrous Material l00%Non- Fibrous Material 100% Non- Fi bro us Material l00%Non- Fibrous Material l00%Non- Fibrous Material Page 6 of 10 Certificate of Analysis PLM Asbestos Identification lel·BSIMiMlll lree · RIH8Mll1 SIJl,Jb(~patriolt.ib.com n A I •• -~T LAB 6640 llllk Blvd., lulteA·IOO, Saollie<Jo, (A 9Z!ZI .-"' ,.~ White Construction Inc. Nancy Young 2524 Gateway Road Carlsbad, CA 92009 Date Collected: 9/7/2021 Date Received: 9n/2021 Date Analyzed: 9/8/2021 Date Reported: 9/8/2021 Lab/Client JD/Layer Location 878108-029 Kitchen. Wall 29 Total Asbestos None Detected 878108-030 Kitchen• Wall 30 Total Asbestos None Detected 878108-031 Kitchen -Floor 31 Total Asbestos None Detected 878108-032 Kitchen -Floor 32 Total Asbestos None Detected 878108-033 Kitchen • Floor 33 Total Asbestos None Detected 878108-034 Kitchen -Floor 34 Total Asbestos None Detected Report Number: 878108 Project Number: SD I 50095 Project Name: Capstone Project Location: 1545 Faraday Avenue Suite 100 Carlsbad, CA 92008 Collected By: Brennan Bales Claim Number: Job #14867 PO Number: Number of Samples: 51 Material Description 4 Inch Cove Base Mastic 12x12 Vinyl Floor Tile Mastic 12x12 Vinyl Floor Tile Mastic Color Black Yellow Black Grey Black Grey Composition ( % ) 100% Non· Fibrous Material 100% Non· Fibrous Material 100% Non- Fibrous Material 100% Non- Fibrous Material 100%Non- Fibrous Material 100% Non· Fibrous Material Page 7 of 10 Certificate of Analysis PLM Asbestos Identification tel -853-654-1221 tree -8l3-l81-Sl21 SIJ!al>&patriollab.rnm DA•· •--~T LAB i640 lusUlvd., SulteA-100, San Di'90, C~ 9lll1 .-'"' '-■.:, White Construction Inc. Nancy Young 2524 Gateway Road Carlsbad, CA 92009 Date Collected: 9/7/2021 Date Received: 9/7/2021 Date Analyzed: 9/8/2021 Date Reported: 9/8/2021 Report Number: 878108 Project Number: SD 150095 Project Name: Capstone Project Location: 1545 Faraday Avenue Suite JOO Carlsbad, CA 92008 Collected By: Brennan Bales Claim Number: Job #14867 PO Number: Number of Samples: 51 Lab/Client ID/Layer Location Material Description Color Composition ( % ) 878108-035 35 Total Asbestos 878108-036 36 Total Asbestos 878108-037 37 Total Asbestos 878108-038 38 Total Asbestos 878108-039 39 Total Asbestos 878108-040 40 Total Asbestos Kitchen -Floor None Detected Kitchen -Floor None Detected 111 -Floor None Detected I 13 -Floor None Detected Conference Room -Floor None Detected Conference Room -Floor None Detected 12x12 Vinyl Floor Tile Mastic Carpet Tile Mastic Carpet Tile Mastic Carpet Ti le Mastic Carpet Tile Mastic Black Grey Grey Grey Grey Grey 100% Non- Fibrous Material 100% Non- Fibrous Material 100%Non- Fibrous Material JOO% Non- Fibrous Material 100% Non- Fibrous Material 100%Non- Fibrous Material Page 8 of IO Certificate of Analysis PLM Asbestos Identification 1e1 • SS8·oiM1l1 free· 8lH8M1l1 SD!ab(~pa!riotlab.com n A I •• Si~T LAB 66-40 lusk 81vd., Sui!< A·IOO, Sao Die<JO, C~ 91111 ■-"" , • .:, White Construction Inc. Nancy Young 2524 Gateway Road Carlsbad, CA 92009 Date Collected: 9/7/2021 Date Received: 9/7/2021 Date Analyzed: 9/8/2021 Date Reported: 9/8/2021 Lab/Client ID/Layer Location 878108·041 0.0. · Floor 41 Total Asbestos None Detected 878108·042 0.0. · Floor 42 Total Asbestos None Detected 878108·043 0.0. · Floor 43 Total Asbestos None Detected 878108·044 Reception -Floor 44 Total Asbestos None Detected 878I08•045 Reception -Floor 45 Total Asbestos None Detected 878I08·046 Hallway • Floor 46 Total Asbestos None Detected Report Number: Project Number: Project Name: Project Location: Collected By: Claim Number: PO Number: 878I08 SD150095 Capstone 1545 Faraday Avenue Suite JOO Carlsbad, CA 92008 Brennan Bales Job #14867 Number of Samples: 51 Material Description Color Composition ( % ) Carpet Tile Mastic Carpet Tile Mastic Carpet Tile Mastic Bamboo Flooring Adhesive Bamboo Flooring Adhesive Bamboo Flooring Adhesive Grey Grey Grey Yellow Yellow Yellow 100% Non- Fibrous Material 100% Non- Fibrous Material 100% Non- Fibrous Material 100% Non• Fibrous Material 100% Non- Fibrous Material 100% Non- Fibrous Material Page 9 or JO Certificate of Analysis PLM Asbestos Identification White Construction Inc. Nancy Young 2524 Gateway Road Carlsbad, CA 92009 Date Collected: 9/7/2021 Dare Received: 9/7/2021 Date Analyzed: 9/8/2021 Date Reported: 9/8/2021 Lab/Client ID/Layer Location !ti·8,8-6S4·Slll lree·8ll·l8Mm SDL.lba,patrioll•b.com nA· •• ..H~T LAB ~o LIISI< lllvd., lurte A·100, san Dil!90, c~ 91121 1-.r,L '-1.:,, Report Number: Project Number: Project Name: 878108 SDI50095 Capstone Project Location: 1545 Faraday Avenue Suite 100 Carlsbad, CA 92008 Collected By: Brennan Bales Claim Number: Job #14867 PO Number: Number of Samples: 51 Material Description Color Composition ( % ) Charlene Kingston -Analyst Michelle Lavallee• Approved By Bulk sample(s) submitted was (were) analyzed in accordance with the procedure outlined in the US Federal Register 40 CFR 763, Subpart F, Appendix A; EPA-600/R-93/i 16 (Method for Determination of Asbestos in Building Materials), and EPA-600/M4-82-020 (US EPA Interim Method for the Determination of Asbestos in Bulk Insulation Samples). Samples were analyzed using Calibrated Visual Estimations (CVES); therefore, results may not be reliable for samples of low asbestos concentration levels. Samples of wall systems containing discrete and separable layers are analyzed separately and reported as composite unless specifically requested by the customer to report analytical results for individual layers. This report applies only to the items tested. Resulb are representative of the samples submitted and may not represent the entire material from which the samples were collected. "None Detected" means that no asbestos was observed in the sample. "<I%'" (less than one percent) or Trace means that asbestos was observed in the sample but the concentration is below the quantiriable level of I%. This report was issued by a NIST/NVLAP (Lab Code 200982-0) and CADOHS-ELAP (Cert. No. 2805) accredited laboratory and may not be reproduced, except in full without the expressed written consent of Patriot Environmental Laboratory Services, Inc. This report may not be u~ed to claim product certifo.:.ition, approval or endorsement by NIST, NVLAP, ELAP or any government agency. ASB_Rep_8.14 Page JO of 10 Lab Use Only: g1 ~ l O ~ Turn Arou~ ,:ime: ( ) ERS N._24 HRS ( ) 48 HRS ( ) 72 HRS lei -858-677-8900 free-855-181-4512 fax -858·617-9009 Patriotlab.com 6640 Lusk Blvd., Suile A-100, San Diego, (A 92121 PAmalr Environmental Laboratory Services, Inc. ASBESTOS FIELD BULK SAMPLE COC Project Name: {--, + I Pro~ct #; _... . __ j Office Use Only: r>-/$ c,/\.t__ 4t'--i/ ,-.....,C,C,,cn D MH Project Address: I ~~ .J ~ 5 F~r:~ A~ City:c_,~.,. /sU Zip?2~ 8 Sample ID Sample Location Material Type F NF Condition Notes J I. c~ ~3~'-'-+--~------¼---+----+----+-+--l----,f-+--+----½----j'~ t--5.-=--~ -+-'-I ~~~---r---------i------;-------~f-----+--------1---------+------4.[1 ~l \~ . u ~.,~ I~ ,II' V \LI ~ ,v R 1-\--'--'-\--+0-=-r-----. (:)_. ------,-l----+---'-""'--'-A--'---"\l_,_\ ~=--:..,__.:.__r...._+-+++---+-+-------------f--------j~ \'2--. w " ' IC'.:in ..c, \C'L \5 ------~f---7----------j ' :.,,,-1 .... \.V \r ' Sampled/Relinauished Bv: SiQn: Samples Received By: Sign: Date: • 4 -''1 Time: , Pag ..__, or-.""'✓---' V Bulk Sample COC Rev 12.27.2017 Lab Use Only: Turn Around Time: ( ) ERS ( ) 24 HRS ( ) 48 HRS ( ) 72 HRS lel-858-677-8900 tree-855-787-4521 fax -858-677-9009 Palriotlab.rnm · 6640 Lusk Blvd., 5uile A-IOO, San Diego, (A 9llll PAm.lt- 1 Environmental Laboratory Services, Inc. ASBESTOS FIELD BULK SAMPLE COC Project Name: I Projec~ o)'XJ<Jtf S, I ~:.!1se Only: Project Address: City: Zip: Sample Sample Location Material Type F NF Condition Notes ID 'l.5,2' l~ltd,e"' -WAH 4 ',:.. ls 1,U\ w/ ,A) o..f+Jc Cov..w11.. X (3.___} ~-A '2'1,Z.I 2q,3o \ ,_ ,,, V '1 VJ ' :_; s1,~, ,--. 1:Z..l<l"2-,· i3lt.c.l<'. A Jt' I 2Cfj-s-J4 ~ \-'" \oor VF--r-wl 4.f C --I ' '3'!>,~ . ··-v-~--~--~ 36,3-G V ' ~ \Y ' V 37 111 -f:r~e. M_as+lc_ 5,A. fl • 1!. ll~ 3\ ~,..ft-- 4b 1 ~ --~ --~ --~·~--~ "1 \ ()•0. - ~z • ,/ ..q3, \Y \ / \ I/ \Y \ i/ '" A4 (le.~ ~"'~~~le ~;;:. ... ('; ~S, ~ I - ,t\(Q \-\~\\~,, 'V' \ I/ ~ ' V ' ii -~, Samoled/Relinnuished Bv: Sian: ~-------~~ Date: --i 1 ~ 'vJ Time: Samoles Received Bv: Sign: I \ Date: IA I I II'\ I Time: Pagl. ""' ........ -, I • I -J Bulk Sample COG Rev 12.27.2017 Project Name: Project Address: tel -858-677-8900 free-855-787-4521 fax -858-677-!009 Palrlollab.oom 6640 lusk Blvd., Suite A-100, San Diego, CA 91111 SAMPLE LOCATION DIAGRAM PA-rmlr Environmental Laboratory Services, Inc. Project#:$/ 50 of5 Loss Type: □ Fire D Water eno D Demo (During/ Upcoming) (Full/ Limited Survey) D Vehicle lmpac 'Sewage □ Confirm Suspect ACM D Other (Specify): ---~- Foundation: Building Type: Level: Frame: □Baised □SF Residential D School Q.:lingle Story D Wood ~ement Slab ommercial D Mobile Home )"'.!Two Story D Brick D Both □MF Residential D Church D Multi -Story i:7Metal # of Un its "I'S Cinder Block Sample Location Dia Date: INTE.RWESl DATE: 10/15/2021 JURISDICTION: City of Carlsbad PLAN CHECK#.: CBC2021-0319.Rcl PROJECT ADDRESS: 1545 Faraday Ave PROJECT NAME: Capstone HQ-TI SET II □ APPLICANT □ JURIS. ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The check list transmitted herewith is for your information. The plans are being held at lnterwest until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ lnterwest staff did not advise the applicant that the plan check has been completed. D lnterwest staff did advise the applicant that the plan check has been completed. Person contacted: Nancy Telephone#: 760-931-1130 Date contacted: (by: ) Email: nancy@whiteconstructioninc.com Mail Telephone Fax In Person 0 REMARKS: By: Ali Doudar for Erich Kuchar lnterwest 10/06/2021 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 , . • 1W I NTERWEST DATE: 9-14-2021 JURISDICTION: Carlsbad PLAN CHECK#.: CBC2021-0319 PROJECT ADDRESS: 1545 Faraday Ave PROJECT NAME: Capstone HQ-Tl SET: I lffl'~tt,ED OCT O O Z02f CITY OF CARLSBAD BUILDING DIVISION 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. IZ! The check list transmitted herewith is for your information. The plans are being held at lnterwest until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. 0 The applicant's copy of the check list has been sent to: D lnterwest staff did not advise the applicant that the plan check has been completed. IZ! lnterwest staff did advise the applicant that the plan check has been completed . Person contacted: Nancy Telephone#: 760-931-1130 Date contacted: (by: ) Email: nancy@whiteconstructioninc.com Mail Telephone Fax In Person 0 REMARKS: By: Erich A. Kuchar, P .E. lnterwest 8-31-2021 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, Californ ia 92 123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 / PLAN REVIEW CORRECTION LIST COMMERCIAL PLAN CHECK#.: CBC2021-0319 OCCUPANCY: B TYPE OF CONSTRUCTION: V-B SPRINKLERS?: Yes DA TE PLANS RECEIVED BY JURISDICTION: 8-25-2021 DATE INITIAL PLAN REVIEW COMPLETED: 9 -14-2021 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad USE: Offices ACTUAL AREA: 5,938 sqft STORIES: 1 + Mezz. HEIGHT: - OCCUPANT LOAD: 142 DATE PLANS RECEIVED BY ESGIL CORPORATION: 8-31 -2021 PLAN REVIEWER: Erich A. Kuchar, P.E. I ._ This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2019 CBC, which adopts the 2018 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2018 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. . . Sheet G4.0 revised site plan and accessible details GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to lnterwest and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to lnterwest, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to lnterwest only will not be reviewed by the City Planning, Engineering and Fire Departments until review by lnterwest is complete. 2. Plans may be submitted in electronic format, subject to the jurisdiction's approval. If so, they must have restrictions removed from the security settings. Electronic plans with restrictions to markups, printing, or stamping will not be approved. 3. A reminder that due to Covid-19, the City will not permit counter corrections. Please make sure all the items are satisfied; otherwise, another round of corrections will be necessary. 4. All plan sheets must be signed by designers. • DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT-TITLE 24 The following disabled access items are taken from the 2019 edition of California Building Code, Title 24. Per Section 1.9.1, all publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities. 5. REMODELS, ADDITIONS AND REPAIRS When alterations, structural repairs or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the following requirements, per Section 11 B-202.4: • T he area of specific alteration, repair or addition must comply as "new" construction. Sheet G4.0 • A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. • The path of travel shall include the existing parking. curb ramp -• Existing toilet and bathing facilities that serve the remodeled area must be shown to comply with all accessibility features. detail #6 CURB RAMPS \I 6. Detectable warnings shall be installed in curb ramps with one or two entrance/ exit points that are 6' or 9' wide, respectively. Section 11-8-705.1.2.2. See Exceptions. For existing structures, the non-truncated domes may be 24" deep instead of 36" deep meaning you must maintain a 5'-0" accessible walkway at curb ramps. 36" deep truncated dome and 24" deep non-truncated dome. Show these dimensions on sheet G4.0 and if sidewalk needs to be widened show how this will be accomplished. .. • Sheet ID5.1 existing restroom plans and elevations provided Sheet G3.0. revised to remove A.2 reference Sheet G3.0. revised urinal detail Sheet G3.0. revised water closet detail. also see ID5.1, elevations - -v 7. 8. 9. 10. 11. SANITARY FACILITIES Provide an enlarged plan view of the existing three bathrooms fully dimensioned and with as-built elevations not just generic details as shown on sheet G3.0 Provide sheet A.2 as referenced on the toilet elevation. RESTROOM FIXTURES AND ACCESSORIES Show, or note, on the plans that accessible urinals meet the following requirements, per Section 11 B-605: a) The rim of at least one urinal shall: i) Project at least 13½ " from the wall. The toilet paper dispenser shall be 7"-9" from edge of toilet not 12". Update. Sheet G3.0. , ~ revised The combination toilet paper dispenser, as shown on plans, is not acceptable. The 1-½" clearance between the grab-bar and the wall is absolute, not subject to construction tolerances to encroach into, as the dispenser will. This is a new change effective July 1, 2018 in the CBC, Sec. 11 B-609.3. Update and show new locations below the grab bar. detail with ~ combo dispenser 12. Remove all shower details as there is no shower. Sheet G3.0. '11 removed accessible ~ ADDITIONAL shower detail 13. MEP and Structural have no comments. 14. Please provide a response list indicating where each correction item has been addressed on the plans. I.e., specify the plan sheet, note, or detail number, calculation page, etc., where the item is corrected on the plans. 15. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: □ Yes □ No 16. The jurisdiction has contracted with lnterwest, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Erich A. Kuchar, P.E. at lnterwest. Thank you. • 1W INTERWEST A SAl'£b4JHI t;OMPAHV DATE: 9-14-2021 JURISDICTION: Carlsbad PLAN CHECK#.: CBC2021-0319 PROJECT ADDRESS: 1545 Faraday Ave PROJECT NAME: Capstone HQ-TI SET: I □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. ~ The check list transmitted herewith is for your information. The plans are being held at lnterwest until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: D lnterwest staff did not advise the applicant that the plan check has been completed. ~ lnterwest staff did advise the applicant that the plan check has been completed. Person contacted: Nancy Telephone#: 760-931-1130 Date contacted: .(by: ) Email: nancy@whiteconstructioninc.com Mail Telephone1 Fax In Person 0 REMARKS: By: Erich A. Kuchar, P.E. lnterwest 8-31-2021 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 PLAN REVIEW CORRECTION LIST COMMERCIAL PLAN CHECK#.: CBC2021-0319 OCCUPANCY: B TYPE OF CONSTRUCTION: V-B SPRINKLERS?: Yes DATE PLANS RECEIVED BY JURISDICTION: 8-25-2021 DATE INITIAL PLAN REVIEW COMPLETED: 9-14-2021 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad USE: Offices ACTUAL AREA: 5,938 sqft STORIES: 1 + Mezz. HEIGHT: - OCCUPANT LOAD: 142 DATE PLANS RECEIVED BY ESGIL CORPORATION: 8-31-2021 PLAN REVIEWER: Erich A. Kuchar, P.E. This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2019 CBC, which adopts the 2018 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulatiorts. Per Sec. 105.4 of the 2018 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. , GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to lnterwest and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to lnterwest, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to lnterwest only will not be reviewed by the City Planning, Engineering and Fire Departments until review by lnterwest is complete. 2. Plans may be submitted in electronic format, subject to the jurisdiction's approval. If so, they must have restrictions removed from the security settings. Electronic plans with restrictions to markups, printing , or stamping will not be approved. 3. A reminder that due to Covid-19, the City will not permit counter corrections. Please make sure all the items are satisfied; otherwise, another round of corrections will be necessary. 4. All plan sheets must be signed by designers. DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT-TITLE 24 The following disabled access items are taken from the 2019 edition of California Building Code, Title 24. Per Section 1.9.1, all publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities. REMODELS, ADDITIONS AND REPAIRS 5. When 'alterations, structural repairs or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the following requirements, per Section 11 B-202.4: • The area of specific alteration, repair or addition must comply as "new" comstruction. • A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. • The path of travel shall include the existing parking. • Existing toilet and bathing facilities that serve the remodeled area must be shown to comply with all accessibility features. CURB RAMPS 6. Detectable warnings shall be installed in curb ramps with one or two entrance/ exit points that are 6' or 9' wide, respectively. Section 11 -B-705.1.2.2. See Exceptions. For existing structures, the non-truncated domes may be 24" deep instead of 36" deep meaning you must maintain a 5'-0" accessible walkway at curb ramps. 36" deep truncated dome and 24" deep non-truncated dome. Show these dimensions on sheet G4.0 and if sidewalk needs to be widened show how this will be accomplished. • • SANITARY FACILITIES 7. Provide an enlarged plan view of the existing three bathrooms fully dimensioned and with as-built elevations not just generic details as shown on sheet G3.0 8. Provide sheet A.2 as referenced on the toilet elevation. RESTROOM FIXTURES AND ACCESSORIES 9. Show, or note, on the plans that accessible urinals meet the following requirements, per Section 11 B-605: a) The rim of at least one urinal shall: i) Project at least 13½" from the wall. 10. The toilet paper dispenser shall be 7"-9" from edge of toilet not 12". Update. 11. The combination toilet paper dispenser, as shown on plans, is not acceptable. The 1-½" clearance between the grab-bar and the wall is absolute, not subject to construction tolerances to encroach into, as the dispenser will. This is a new change effective July 1, 2018 in the CBC, Sec. 11 B-609.3. Update and show new locations below the grab bar. 12. Remove all shower details as there is no shower. ADDITIONAL 13. MEP and Structural have no comments. 14. Please provide a response list indicating where each correction item has been addressed on the plans. I.e., specify the plan sheet, note, or detail number, calculation page, etc., where the item is corrected on the plans. 15. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: □ Yes □ No 16. The jurisdiction has contracted with lnterwest, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Erich A. Kuchar, P. E. at lnterwest. Thank you. . ' [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Erich A. Kuchar, P.E. BUILDING ADDRESS: 1545 Faraday Ave BUILDING OCCUPANCY: B BUILDING AREA Valuation PORTION (Sq.Ft.) ~ier Tl 5938 46.51 Air Condilioring Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance ii I 1997 UBC Bu ding P<r mit fee ... I ,".I ,,·I: ] 1997 USC Pfan Check Fee .:!'.1 1 ·,,.·,1 :::i: Type of Review: r,; Complete Review r Repetitive Fee r Other .. r-..-! Repeats r HolA'ly EsGilFee r r Reg. Mod. PLAN CHECK#.: CBC2021-0319 DATE: 9-14-2021 VALUE ($) 276,176 276,176 1 ) r Structural Only ]Hr.@* $815.37) Sheet 1 of 1 PCSD Engineering Corp 3529 Coastview Court Carlsbad, CA 92010 Ph: 760·207 1885 Structural Design Calculations Tenant Improvement Client White Construction 2524 Gateway Road Carlsbad. CA 92009 Proiect August 13, 2021 PCSD File#: 21-424.1 ~~~. ,,..✓ '"' 1.-,. r•,\1,! ,'i\,,,t,•;i,<'01 ~A-•• r,,,.,,a .;.H,ll'1 ... t'1"1'1<l' I h Paul Christenson San Diego Engineering 3529 Coastview Ct -Carlsbad, CA 92010 Telephone (760) 207-1885-Email: paul.pcsd@gmail.com 1.0 Design Criteria: Capstone HQ 21-424.1 Code: Timber: 2019 California Building Code -ASCE 7-16 Douglas Fir-Larch (DF-L), WWPA or WCLIB 2x Wall Framing: DF-L #2 (unless noted otherwise) 2x Rafters & Joists: DF-L #2 " " Posts & Beams: DF-L #1 • Glue-Lam Beams: Simple Span: Grade 24F-V4 (DF/DF) Grade 24F-V8 (DF/DF) Cantilevers: Sheathing: Min. APA-Rated Sheathing, Exposure 1, Plywood or OSB (U.N.O.) Engineered Framing Wood /-Joists: TJI 110,210,230,360,560 ICC ESR-1153 1.9E Microllam, 2.0E Parallam ICBO ER-4979 Concrete: Concrete Block: Mortar: Grout: LVL, PSL Compressive Strength @ 28 days per ASTM C39-96: Footings: f'c = 2500 psi Grade Beams: f'c = 3000 psi Grade N-I per ASTM C90-95, fm = 1500 psi per ASTM E447-92 Type S Mortar Cement per ASTM C270-95, Min. f'm = 1800 psi@ 28 days. Coarse Grout w/ 3/8" Max. Aggregate per ASTM C476-91, Min. fm = 2000 psi @ 28 days. Reinforcing Steel: #4 & Larger: #3 & Smaller: ASTM A615-60 (Fy = 60 ksi) ASTM A615-40 (Fy = 40 ksi) Structural Steel: 'W' Shapes: ASTM A992, Fy= 50-65 ksi Plates, Angles, Channels ASTM A36, Fy = 36 ksi Tube Shapes: ASTM A500, Grade B, Fy= 46 ksi Pipe Shapes: ASTM A53, Grade B, Fy=35 ksi Welding Electrodes: Structural Steel: E70-T6 E90 Series Bolts: Soils: References: A615-60 Rebar: Sill Plate Anchor Bolls & Threaded Rods: Steel Moment & Braced Frames: 1500 psf Bearing Pressure A307 Quality Minimum A325 (Bearing, U.N.O.) ~ ,u/f;",t.r/ne.nJ'O.n ';/,m ~o :&JV'een.nJ JOB SHEET NO CALCULATED BY CHECK BY 3529 Coastview Ct -Carlsbad, CA 9201 0 SCALE Telephone (760) 207-1885 -Email: paul.pcsd@gmail.com 2.0 LOAD LIST 2.1 Roof <Vaulted) Roofing 15/32" Sheathing Roof Framing 5/8" Gyp. Bd. Insulation and Misc. IoL = ILL= Total Load= 2.2 Roof (w I ceiling) Roofing 15/32" Sheathing Roof Framing Insulation and Misc. 2.3 Ceiling Ceiling Joists IoL = ILL= Total Load= 5/8" Gyp. Bd. Insulation and Misc. 2.4 Walls IoL = ILL= Total Load= Exterior Wall 7 /8" Stucco 15/32" Sheathing 2x4 Studs @ 16" o.c. 5/8" Gypsum Bd. Misc. 6.0 psf 2.0 psf 2.8 psf 2.8 psf 1.4 psf 15.0 psf 20.0 psf 35.0 psf 6.0 psf 2.0 psf 2.8 psf l.2 psf 12.0 psf 20.0 psf 32.0 psf 1.3 psf 2.8 psf l.9 psf 6.0 psf 10.0 psf 16.0 psf 9.0 psf l.5 psf I.I psf 2.8 psf 0.6 psf 15.0 psf Interior Wall 1/2" Gyp. Bd. (2 Sides) 2x4 Studs@ 16" o.c. Misc. 21-424.1 f,,. PSC 4.6 psf 1.1 psf 2.3 psf 8.0 psf OF DATE DATE 8/13/21 .?7,ru/"C,f'r/ne:11.n,:11 e/n, ~ .. :&_pneermJ 3529 Coastview Ct -Carlsbad, CA 9201 0 JOB 21-424.1 ~ OF PSC DAT_E_S,_/~13'"'12,-1~ DATE SHEET NO CALCULATED BY CHECK BY SCALE --------- Telephone (760) 207-1885 -Email: paul.pcsd@gmail.com 2.0 LOAD LIST (CONTINl 2.5 Floor Floor Cover Sheathing 2x F.J. 5/8" Gyp. Bd. Insulation and Misc. loL = ILL= Total Load= 5.5 psf 2.3 psf 3.1 psf 2.8 psf 1.3 psf 15.0 psf 40.0 psf (60.0 psf -Decks) 55.0 psf WIND PARAMETERS 2.6 Wind Basic Wind Speed = 110 mph Exposure Cat = B Ps = >-.Kzt•l*Ps30 P= 26.6 psf P = 16.0 psf 2.7 Seismic Sos= 0.792 Sos Cs= (R/1) Cs= 0.198 USE: V= 0.198 WoL (ASCE 7-16 -Equation 28.5-1) (*0.6 ASD) (11.4.5) ASD BASE SHEAR VASD VAfln= 0.141 WoL >,. = 1.00 (fig. 28.5-1) Ps30= 26.6 psf Kzt = 1.00 (fig. 26.8) I= 1.0 USGS APPLICATION S, = 0.99 S1 = 0.361 F,= 1.20 F = ' 0.00 R= 4 I= 1.00 h, = 20.00 Occupancy Category: 2 Site Class: D SEISMIC DESIGN CATEGORY s. <0.75 S1 >o.04 Ss>o.1s (11.6 ASCE 7-16) (11.4.2 ASCE 7-16) (fig. 28.5-1) (table 1.5-2) T, = C, • (l,,,J°-75 = 0.189 Ts = So/Sos-0 k= 1.0 ~qn. 12.8-1 Not OJ Ta<0.5 Seismic Design Category: D MEMBER REPORT Aoor Framing, (FB-1) Fir Bm PASSED 1 plece(s) 3 1/2" x SI 1/2" 2.2E Parallam® PSL ~1 ... . 0 0 All locations are measured from the outside face c:I left support ( or left cantilever end). All dimensions are hor1zontal. .. ' . :,~\~i ~;'i,~-~!#J, ~~--t . ' n, ·: ~;~~§J, Member Reaction {lbs) 2764@2" 7656 (3. 50") Shear (lbs) 1819@ 1' 1" 6428 Moment (Ft-lbs) 3928@ 3' 2" 13057 Uve Load Def!. (In) 0.039@3' 2" 0.200 Total Load Den. (In) 0.059@3' 2" 0.300 • Oellectlor, ~: LL (l/360) and Tl (l/2'40) . • Allowed moment does not reflect the adjustment ror the beam stablAty factor. lliiiii.ii' t.;.<W1~1:.z;m -.~.~}-. "· ;,• Passed {36%) -- Passed {28%) 1.00 Passed (30%) 1.00 Passed (l/999+) -- Passed (l/999+) -- ~~,,,,.,, . ~•'.;;\~t-~$~ 1.0 D + 1.0 L (All Spans) 1.0 D + 1.0 L (All Spans) 1.0 D + 1.0 L (All Spans) 1.0 D + 1.0 L (All Spans) 1.0 D + 1.0 L (All Spans) SY5leffl : Floor Member Type : Drop Beam Building Use : Residential Building c.ode : !BC 2018 Design Methodology : ASD • llloclclng Panels are assumed ID cany no loads applied directly abcM! them and the Ml load Is alll)lled II> the member being designed. •Maximum allowable bracing lnlZfvals based on applied load. 1 • Uniform (PSF) Weyemaeuser ~nts !hat the sizing of Its products wiN be In aa::ordance wtth Weyerhaeuser product design critiena and published design value. Weyerhaeuser e,cpressly disclaims any other w.r111t1es ~ to the software. Use of this software Is not lnbendtd to drcun,,;ent the need for a desq, pro!Mslonal as deliennined by the authonty having Jurisdiction. The designer of record, builder or framer Is responsible ID assure !hat this calculation ts compeUble wtth the overall project. Accessories (Rim Boerd, Blocking Panels and Squash Blocks) are not de5lgned by this softwate. Products manufactured at W~ fadllties are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluab!d by ICC-ES under evaluation reports ESR-1153 and ESR-1387 r,d/or tested In aax,rdance wllh appllcable ASTM standards. !'or current axle evaluation reports, Weyerhaeuser proc!uct •~re and instalatlon oetans refer to www.~ser.mm/woodproci.m/document-Ntn,y. The product a,lllllcatlon, Input design iollds, dimensions and support Information have Ileen provided by ForteWEB Software C)peratcr Paul Ov1sten5on PCSO fngl,-ing (760) 207-1885 paul.pc:sdOomall .(X)lll JobNotlll A Weyerhaeuser 10/20/2021 6:27:04 PM UTC ForteWEB v3.2, Engine: VB.2.0.17, Data: VB.1.0.16 File Name: capstone Paael /1 PCSD Engineering Corp 3529 Coastview Court Carlsbad, CA 92010 Ph: 760-207-1885 -c. 0~ '1W.J.. ., .: 1~6•' a,....,c,,1,.((,f,.'h• lZr,11,t"n.u, 1.:~,. "01"' "11•-> WDuf> -- Job#: 1 \· 4 ·1.'f Page: C of __ , ___ _ Date: _________ _ Engineer: _______ _ ,?,u/"{;,tn'.d,n,o,t ;f,,, ~o :&yn#NIJ 3529 Coastview Ct -Carlsbad, CA 92010 Telephone (760) 207-1885-Email: paul.pcsd@ mail.com 6.0 FOUNDATION DESIGN 6.1 CONTINUOUS FOOTING w = 1125 plf width = ~ plf 1500 psf 0.75 ft (MIN.) => 9 INCHES (MlN.) ( E) 15 "WIDE CONTIN. FTG W/ l -# 4 TOP AND BOTTOM & EMBED. 18 "INTO UNDISTURBED SOIL (MIN.) 6.2 MAX POINT LOAD ON FOOTING JOB 21-424.1 SHEET NO t, OF _ _,b __ _ CA LC ULA TED BY PSC DATE 8/13/21 CHECKBY ____ DATE __ _ SCALE ASBP = 1500 psf Pa11= 1500 • ~ • ~ 12 12 P a11 = 7500 lbs I. I I OFFICE USE ONLY SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE RECORD ID # ___________________ 1 PLAN CHECK # __________________ 1 usiness Name CWHQ Carlsbad, LLC c/o Capstone Advisors Project Address (include suite) 1545 Farada Ave Suite 100 Mailing Address (include suite) 1545 Farada Ave Suite 100 Project Contact Chad Johnston Business Contact Chad Johnston Telephone# (760) 827-6010 City State Zip Code Carlsbad CA 92008 City State Zip Code Carlsbad CA 92008 Applicant E-mail Telephone# ·ohnston capstoneadvisors.com (760) 827-6010 BP DATE APN# 212-130-29-00 Plan File# CBC2021-0319 The following questions represent the facility's activities, NOT the specific project description. I PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: (not required for projects within the City of San Diego): Indicate by circling the item. whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: B (Office) Facility's Square Footage (including proposed project): 5,938 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 2. Compressed Gases 6. Oxidizers 10. Cryogenics 3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 4. Flammable Solids 8. Unstable Reactives 12. Radioactives 13. Corrosives 14. Other Health Hazards j15. None of I hese. I PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION (HMO): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Avenue, Suite 170, San Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building permit. FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy: 0 CalARP Exempt YES NO (for new construction or remodeling projects) I 0 IX) Is your business listed on the reverse side of this form? (check all that apply). Date Initials 1. 2. 3. 4. 5. 6. 7. 8. 0 IX) Will your business dispose of Hazardous Substances or Medical Waste in any amount? D IX) Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 D D D D D pounds and/or 200 cubic feet? IX) Will your business store or handle carcinogens/reproductive toxins in any quantity? IX) Will your business use an existing or install an underground storage tank? IX) Will your business store or handle Regulated Substances (CalARP)? IZI Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? IX) Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to or greater than 1.320 gallons? (California's Aboveground Petroleum Storage Act). 0 CalARP Required I Date Initials 0 CalARP Complete I Date Initials PART 111: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCD): The following questions are intended to identify the majority of air pollution issues at the planning stage. Your project may require additional measures not identified by these questions. Some residential projects may be exempt from APCD requirements. If yes is answered for either questions 1, 2 or 5 or for more comprehensive requirements, please contact APCD at apcdcomp@sdcounty.ca.gov; (858) 586-2650; or 10124 Old Grove Road, San Diego, CA 92131. YES NO 1. ~ 0 Will the project disturb 100 square feet or more of existing building materials? 2. 0 [2S] Will any load supporting structural members be removed? 3. ~ 0 (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by an individual that has passed an EPA-approved building inspector course? 4. D lig (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Based on the survey results, will the project disturb any asbestos containing material? If yes, a notification may be required at least 10 working days prior to commencing asbestos removal. Additionally, a notification may be required prior to the removal of a load supporting structural member(s) regardless of the presence of asbestos. 5. D ~ Will the project or associated construction equipment emit air contaminants? See the reverse side of this form for typical equipment requiring an APCD permit. If yes, contact APCD prior to the issuance of a building permit. 6. 0 0 (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school bounda ? Briefly describe business activities: Briefly describe proposed project: Real estate office Existing interior office Tl I declare under penalty of perjury that to the best of my knowledge and bet Nancy Young, PM 09 I 30 / 21 Name of Owner or Authorized Agent Date FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: _________________________________ _ BY· DATE· I I EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMO· APCD COUNTY-HMO APCD COUNTY-HMO APCD ~~'-\.on Co,,~ <:.;:; o.,... .... Rt:-v1ewed <2 < 09/30/2021-MF C t'n:t."i101tti:JIS s ~,:, ,,., ,i; ),ego c,o •A stamp in this box only exempts businesses from completing or updating a Hazardous Matenals Business Plan. Other perm,tt,ng requirements may still apply HM-9171 (9/18) County of San Diego -DEH -Hazardous Materials Division DocuSign Envelope ID: C4B35f6C-529f-4385-B862-3DDAD94ff85C ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com Date: 8/31/2021 Business Name: CWHQ Carlsbad, LLC c/o Capstone Advisors Street Address: 1545 Faraday Avenue Email Address: johnston@capstoneadvisors.com PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) [K] Check all below that are present at your facility: o Acid Cleaning o Assembly o Automotive Repair o Battery Manufacturing o Biofuel Manufacturing o Biotech Laboratory o Bulk Chemical Storage o Car Wash o Chemical Manufacturing o Chemical Purification o Dental Offices • Dental Schools • Dental Clinics o Dry Cleaning o Electrical Component Manufacturing o Fertilizer Manufacturing o Film/X-ray Processing o Food Processing o Glass Manufacturing o Industrial Laundry o Ink Manufacturing o Laboratory o Machining/Milling o Membrane manufacturing (i.e. water filter membranes) o Metal Casting/Forming o Metal Fabrication o Metal Finishing • Electroplating • Electroless Plating • Anodizing • Coating (i.e. phosphating) • Chemical Etching/Milling • Printed Circuit Board Manufacturing o Metal Powders Forming o Nutritional Supplement/Vitamin Manufacturing o Painting/Finishing o Paint Manufacturing o Personal Care Products Manufacturing o Pesticide Manufacturing/ Packaging o Pharmaceutical Manufacturing (including precursors) o Porcelain Enameling o Power Generation o Print Shop o Research and Development o Rubber Manufacturing o Semiconductor Manufacturing o Soap/Detergent Manufacturing o Waste Treatment/Storage New Business? Yes O No O SIC Code(s) if known: _____ _ Date operation began/will begin: ______ _ Tenant Improvement? Yes O NoO If yes, briefly describe improvement: _________________ _ Description of operations generating wastewater (discharged to sewer, hauled or evaporated): __________ _ Estimated volume of industrial wastewaterto be discharged (gal/ day): __________________ _ List hazardous wastes generated (type/volume): __________________________ _ Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? Yes D Date: ____ No 0 Pagelof2 DocuSign Envelope ID: C4B35F6C-529F-4385-B862-3DDAD94FF85C ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com The commercial enterprises listed below are a partial listing of businesses that are exempt from industrial wastewater discharge permitting under normal operating conditions. They are exempt because (a) they discharge no process wastewater (i.e., they only discharge sanitary wastewater with no pollutants exceeding any local limits), and (b) they have no potential to negatively impact the EWPCF or other wastewater treatment plants in the ESS. Any questions regarding exemptions should be referred to EWA Source Control staff. o Automobile Detailers o Hotels/Motels (no laundry) o Barber /Beauty Shops o Laundromats o Business/Sales Offices o Libraries o Cleaning Services o Medical Offices (no x-ray developing) o Carpet/Upholstery o Mortuaries o Childcare Facilities o Museums o Churches o Nail Salons o Community Centers o Nursing Homes o Consulting Services / o Office Buildings (no process flow) o Contractors o Optical Services o Counseling Services o Pest Control Services (no pesticide repackaging for sale) o Educational Services (no auto repair/film developing) o Pet Boarding/Grooming Facilities o Financial Institutions/Services o Postal Services (no car wash/auto repair) o Fitness Centers o Public Storage Facilities o Gas Stations (no car wash/auto repair) o Restaurants/Bars o Grocery Stores (no film developing) o Retail/Wholesale Stores (no auto repair/film developing) o Residential based Businesses o Theaters (Movie/Live) CERTIFICATION STATEMENT I certify that the information above is true and correct to the best af my knowledge. DocuSigned by: Signatu r ~"' 2°~11, Print Name: ___________ _ Chad Johnston DATE: 8/31/2021 303897D1C591482 Facility Contact: ___________ _ Title: --------------- ENCi NA WASTEWATER AUTHORITY 6200 AVENIDA ENCINAS, CARLSBAD, CA Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com Page 2 of 2 DocuSig n Envelope ID: 258682E6-4003-4411-AA6C-B88803A851 DE (city of Carlsbad CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division < 1635 Faraday Avenue www.carlsbadca.gov PURPOSE This checklist is intended to help building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their project. This completed checklist (B-50) must be included with the building permit application. The Carlsbad Municipal Code (CMC) can be referenced during completion of this document by clicking on the provided links to each municipal code section. NOTE: The following type of permits are not required to fill out this form ❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool Consultation with a certified Energy Consultant is encouraged to assist in filling out this document. Appropriate certification includes, but is not limited to: Licensed, practicing Architect, Engineer, or Contractor familiar with Energy compliance, IECC/HERS Compliance Specialist, ICC GS Energy Code Specialist, RESNET HERS rater certified, certified ICC Residential Energy Inspector/Plans Examiner, ICC Commercial Energy Inspector and/or Plans Examiner, ICC CALgreen Inspector/Plans Examiner, or Green Building Residential Plan Examiner. If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, check NIA and provide an explanation or code section describing the exception. Details on CAP ordinance requirements are available at each section by clicking on the municipal code link provided. The project plans must show all details as stated in the applicable Carlsbad Municipal Code (CMC) and/or Energy Code and Green Code sections. Project Name/Building Permit No.: Property Address/APN: Applicant Name/Co.: Applicant Address: Contact Phone: CBC2021-0319 1545 Faraday Avenue, Suite 100, Carlsbad, CA 920081/// APN: 212-130-29-00 Chad Johnston -CWHQ Carlsbad, LLC c/o Capstone Advisors 1545 Faraday Avenue, Suite 100, Carlsbad, CA 92008 (760) 827-6010 Contact Email: johnston@capstoneadvisors.com Contact information of person completing this checklist (if different than above): Name: Company name/address: Chad Johnston Capstone Advisors Contact Phone (760) 827-6010 Contact Email: johnston@capstoneadvisors.com 8/27/2021 Date: ________ _ Page1of7 Revised 04/21 DocuSign Envelope ID: 25B682E6-4003-4411-AA6C-B88803A851 DE ' Use the table below to determine which sections of the Ordinance checklist are applicable to your project. For alterations and additions to existing buildings, attach a Permit Valuation b[reakdown on a separate sheet. Building Permit Valuation (BPV) $ breakdown -'1'-'-7--=0_,_,,6'--'9---'4 ____ _ A high,tiseresidentialbuilding 1s4 or morestoiies, in6Judin'g'~ Low-rise High-rise mixed04se building in which atleast 20% of its c~~d!ll9n~di(!p,o/,f area isresidential use · · ' ' □ New consbucfion 2A', 3A', 1B, 2B, 'Includes detached, newly constructed ADU 4A', 3B,4A □ Additions and alterations: □ BPV < $60,000 N/A N/A All residential additions and alterations □ BPV" $60,000 1A, 4A 4A 1-2 family dwellings and townhouses with attached garages □ Electrical service panel upgrade only only. □ BPV" $200,000 1A, 4A' 'Multi-family dwellings only where interior finishes are removed 1 B, 4A' and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed ' □ New consbucfion 1 B, 2B, 3B, 4B and 5 11!1 Alterations: <$200k Tl in existing office building )&G BPV" $200,000 or additions" 1,000 square feet 1B, 5 □ BPV" $1,000,000 1B, 2B, 5 Building alterations of" 75% existing gross floor area □ " 2,000 sq. ft. new roof addition 2B, 5 1B also applies if BPV" $200,000 1. Energy Efficienty Please refer to Cansbad Municipal Code (CMC) 18.21.155 and 18.30.190,and the California Green Building Standards Code (CALGreen) for more infonmation. Appropriate details and notes must be placed on the plans according to selections chosen in the design. A. D Residential addition oralteration2:$60,000 building penmitvaluation. □ N/A,_cN=A,_ ________ _ Details of selection chosen below must be placed on the plans referencing CMC □ Exception: Home energy score" 7 18.30.190. (attach certification) Year Built Single-family Requirements Multi-family Requirements □ Before 1978 Select one option: □ Ductsealing □ Attic insulation □Cool roof □ Attic insulation □ 1978 andlater Select one option: □ Lighting package □ Water heating Package □ Between 1978 and 1991 Select one option: □ Ductsealing □ Attic insulation □Coo/roof □ 1992 and later Select one option: □ Lighting package □ Water heating package Updated 4/16/2021 ( 3 DocuS1gn Envelope ID: 25B682E6-4003-4411-AA6C-B88803A851 DE ., B. \ Nonresidential' new construction or alterations l: $200,000 building pennit valuation, or additions l! 1,000sq uare feet See CMC 18.21'155 and CALGreen Appendix AS !!I NIA N/A ~--------- AS.203.1.1 Choose one:□. 1 Outdoor lighting D .2 Restaurant service water heating (CEC 140.5) D .3 Warehousedockseal doors. D .4 Daylight design PA,-s D .5 Exhaustairheatrecovery !!I N/A N/ A A5.203.1.2.1 Choose one:□ .95 Energy budget (Projects with indoor lighting OR mechanical) □ .90 Energy budget (ProjectswithindoorlightingANDmechanical) I!!! N/A N/ A AS.211.1" □ On-site renewable energy: ~ NIA N/A AS.211.3~ D Green power (If offered by local utility provider, 50% minimum renewable sources) Iii N/A N/A AS.212.1 D Elevators and escalators: (Project with more than oneelevatorortwo escalators) ~ N/A N/A AS.213.1 □ Steel framing: (Provide details on plans for options 1-4 chosen) ~ N/A N/A * Includes hotels/motels and high-rise residential buildings •• Foralterations~ $1,000,000 BPV and affecting> 75%existing grossfloorarea, OR alterations that add 2, OOOsquarefeetof newroofaddition: comply with CMG 18.30.130 (section 2B below) instead. 2. Photovoltaic Systems A. 0 Residential new construction (for low-rise residential building permit applications submitted after 1/1/20). Refer to 2019 California Energy Code section 150.1{c)14 for requirements. If project includes installation of an electric heat pump water heater pursuant to CAP section 3B below(low-rise residentialWaterHeating), increase system size by .3kWdc if PV offset option is selected. Floor Plan ID (use additional CFA #d.u. Calculated kWdc* sheets if necessary) Total System Size: kWdc = (CFAx.572) / 1,000 + (1.15 x #d.u.) *Formula calculation where CFA ;::;:: conditional floor area, #du;::;:: number of dwellings per plan type If proposed system size is less than calculated size, please explain. kWdc Exception D D D D B. D Nonresidential new construction or alterations l:$1,000,000 BPV AND affecting l:75% existing floor area, OR addition that increases roof area by l!2,000 square feet Please refer to CMC 18.30.130 when completing this section. 'Note: This section also applies to high-rise residential and hotel/motel buildings. Choose one of the following methods: □ Gross Floor Area (GFA)Method GFA: □ If< 10,000s.f Enter: 5 kWdc Min.System Size: □ If< 10,000s.f. calculate: 15 kWdcx (GFA/10,000) •• kWdc **Round building size factor to nearest tenth, and round system size to nearest whole number. Updated 4/16/2021 4 DocuSign Envelope ID: 256682E6-4003-4411-AA6C-B88803A851 DE □ Time-Dependent Valuation Method Annual TDV Energy use:*** _______ x .80= Min. system size: ______ kWdc ··• Attach calculation documentation using modeling software approved by the California Energy Commission. 3. Water Heating A D Residential and hotel/motel new construction. Refer to CM€ 18.30.170 when completing this section. Provide complete details on the plans. □ For systems serving individual dwelling units choose one system: □ Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) □ Heat pump water heater AND PV system .3 kWdc larger than required in CMC 18.30.130 (high rise residential hotel/motel) or CA Energy Code section 150 1(c) 14 (low-rise residential) D Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher D Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors D Exception: D For systems serving multiple dwelling units, install a central water-heating system with ALL of the following: D Gas or propane water heating system D Recirculation system per CMC 18.30.150(8) (high-rise residential, hotel/motel) or CMC 18.30.170(8) (low- rise residential) D Solar water heating system that is either: D .20 solar savings fraction D .15 solar savings fraction, plus drain water heat recovery D Exception: B. D Nonresidential new construction. Refer to CMC 18.30.150 when completing this section. Provide complete details on the plans. D Water heating system derives at least 40% of its energy from one of the following (attach documentation): D Solar-thermal □ Photovoltaics D Recovered energy D Water heating system is (choose one): D Heat pump water heater D Electric resistance water heater(s) □Solar water heating system with .40 solar savings fraction D Exception: It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. Updated 4/16/21 5 DocuSign Envelope ID: 25B682E6-4003-4411-AA6C-B88803A851 DE 4. Electric V~hicle Charging A. 0 Residential New construction and major alterations• Please refer to CMC 18.21.140 when completing this section. □ One and two-family residential dwelling or townhouse with attached garage: □ One EVSE Ready parking space required □ Exception : -□ Multi family residential· □ Exception Total Parking Spaces EVSE Spaces Proposed EVSE (10% of total) Installed (50% of EVSE) Other "Ready" Other "Capable" Calculations: Total EVSE spaces= .1 Ox Total parking spaces proposed(rounded upto nearestwhole number) EVSE Installed= Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other may be "Ready" or "Capable" *Major alterations are: ( 1 ) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation~$60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), alterations have a building penmit valuation~ $200,000, interior finishes are removed and significantsitework and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed. 'ADU exceptions for EV Ready space (no EV ready space required when): (1) The accessory dwelling unit is located within one-half mile of public transit. (2) The accessory dwelling unit is located within an architecturally and historically significant historic district. (3) The accessory dwelling unit is part of the proposed or existing primary residence or an accessory structure. (4) When on-street parking permits are required but not offered to the occupant of the accessory dwelling unit. (5) When there is a car share vehicle located within one block of the accessory dwelling unit. B. D Nonresidential new construction (includes hotels/motels) □ Exception : _____________ _ Please refer to CMC 18.21.150 when completing this section Total Parking Spaces Proposed EVSE (10% of total) I Installed (SO% of EVSE) Other "Ready" Other "Capable" I Calculation· Refer to the table below: Total Number of Parking Spaces provided Number of required EV Spaces Number of required EVSE Installed Spaces □ 0-9 1 1 □ 10-25 2 1 □ 26-50 4 2 □ 51-75 6 3 □ 76-100 9 5 □ 101-150 12 6 □ 151-200 17 9 □ 201 and over 1 D percent of total 50 percent of Required EV Spaces Calculations: TotalEVSEspaces=.10xTotalparking spaces proposed (roundeduptonearestwholenumber) EVSE Installed= Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other may be "Ready'' or "Capable" Updated 4/16/2021 6 DocuSign Envelope ID: 25B682E6-4003-4411-AA6C-B88803A851 DE An approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT. City staff will use the table below based on yoursubmitted plans to detenminewhetherornoryourpenmit requires a TDM plan. lfTDM is applicable to your permit, staff will contact the applicantto develop a site-specific TOM plan based on the permit details. Acknowledgment: Employee ADT Estimation for Various Commercial Uses Office (all), 20 Restaurant 11 Retail, 8 Industrial 4 Manufacturing 4 Warehousing 4 1 Unless otherwise noted, rates estimated from /TE Trip Generation Manual, 10thEdition 13 11 4.5 3.5 3 1 2 For all office uses, use SANDAG rate of 20 ADT/1,000 sf to calculate employee ADT , Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration Sample calculations· Office: 20,450 sf 1. 20,450 sf/ 1000 x 20 = 409 Employee ADT Retail: 9,334 sf 1. First 1,000 sf= 8 ADT 2. 9,334 sf -1,000 sf= 8,334 sf 3. (8,334 sf/ 1,000 x 4.5) + 8 = 46 Employee ADT I acknowledge that the plans submitted may be subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should my permit require a T g)OOJl,IW,,Vnderstand that an approved TDM plan is a condition of penmit issuance. c.,___...,., l'\W'l:.,k,I'\, s;21 ;2021 ApplicantSignature:+---cc==~7=,,.-------------Date: ______ _ Person other than Applicant to be contacted for TDM compliance (if applicable): Name(Printed): __________________ _ Phone Number _____ _ Email Address: ___________________ _ Updated 4/16/2021 7 C l I ii I i • ., ~ l i ~ •I, ~! .• (i i "e e ~ .. ..-~ ..... "' i . ~ j ~ ' gooz6 vJ '1"'9'1..,J ~;;i,,,v fEpe.ied ,,;v,:;1 OH ;:cJUO'.fSdr?J f-- ~ ' ~ -~~ "' -• ~ 0 l i,t) f lg ~ 2 @ E8 J - I: r-- I/ ~ ~~ ~ -• ' 0 • ---------------~-----~~~-~~---------gooz6 VJ 'P"9'1"J ;;;ru;;;AV ht'.'pE?..E'J '::ilr'::il OH ;;>UO'.}Sdl?J - ~ _\ I:\_ z C) ':c <;:,. z :::, C) IL ' z C) ':c > C) z \;z ll.\ u IL IL C) ~~ b 1B ,-t ~\ _j ~ ~ "'-' I-" ~, G I n M ~ i I I ' I I I I ~ _\ I:\_ ~~= 13 ts -~ z ' I ! ' LJ IL 13 iEP . ~ z _\ ll.\ B, . ~-.,;; ~ u ' z ~ ~8 ~I C) ':c > J C) z ' \;z a ll.\ u ' IL IL C) ~~ ~ 0 "' - . •